HomeMy WebLinkAbout1755 VALLEY PL; ; CB162221; Permit1755 valley P1 BLDG-Residential 2050803300 $136,585.00 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Description: Applicant: STEVE LUTZKE 760-468-3333 KAMINSKI: 730 SF ADDITION FOR NEW MASTER BED // 325 SF ROOF DECK OVER MASTER //231 SF STORAGE ROOM OVER MASTER /f EXTERIOR SPIRAL STAIRS Owner: CASEY P KAMINSKI 1755 valley P1 CARLSBAD, CA 92008 Work Class: Addition Lot #: Reference #: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Status: Closed - Finaled Applied: 06/08/2016 Issued: 11/17/2016 Finaled: Inspector: JWest City of Carlsbad 1635 Faraday AV Carlsbad, CA 92008 Print Date: 07/03/2017 Residential Permit Permit No: CB162221 www.carlsbadca.gov BUILDING PERMIT FEE $2000+ $757.35 DRAINAGE FEE PIDA A Low Runoff $1,317.75 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $66.00 GREEN BUILDING STANDARDS PLAN CHECK $166.00 MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL $92.00 PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL $182.00 5B1473 BUILDING STANDARDS FEE $5.46 STRONG MOTION-RESIDENTIAL $17.76 SWPPP INSPECTION FEE TIER 1- Medium $232.00 SWPPP PLAN REVIEW FEE TIER 1- MEDIUM $55.00 Total Fees: $2,891.32 Total Payments To Date: $2,891.32 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 4ITHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: DPLANNING []ENGINEERING 0 Building Permit Application City of 1635 Faraday Ave., Carlsbad, CA 92008 CCr Ph: 760-602-2719 Fax: 760-602-8558 ceir1sbid. email: building©carlsbadca.gov www.carlsbadca.gov JOB ADDRESS \i1 \•/ \\_. <:2_lIE- SUITEC,'SPACE#/UNIT# CT/PROJECT # LOT U PHASE U U OF UNITS I # BEDROOMS I U BATHROOMS i TENANTfl I-_ LDING DFIRE 0 HEALTH DHAZMATIAPCD Plan Check No. CPS I to 22I Est. Value L,i_o ,5%5 Plan Ck. Deposit Date (_p—'—K.o SWPPP I(o APN - - _.... . I L S Li i'id- ,.Lek— 52 \O voz L I EXISTING USE 'Frc% PROPOSED USE I DECKS (SF) I FIREPLACE I AIRCONDITIONING IFIRESPRINKLERS GARAGE (SF) PATIOS (SF) I IYESI:I#_NoII YES NO D YES j NO APPLICANT NAME PROPERTY OWNER o.c Primary Contact ADDRESS ADDRESS C CITY STATE ZIP C -r STATE ZIP DESIGN PROFESSIONAL \Sq CONTRACTOR BUS NAME CITY STATE ZIP CITY STATE ZIP C A' —k l.X PHONE PHONE FAX EMAIL EMAIL (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair anystructure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). (a 13 ®COTh)®() Workers' Compensation Declaration: I here by affirm under penalty of perjury one of the following declarations: i:i I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation Insurance carrier and policy number are: Insurance Co. Policy No. Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less. []Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (8100,000), in addition to the cost of compensation, damages ided for in Se 0n 06o1 the Labor c A terest and attorney's fees. CONTRACTOR SIGNATURE , 0 AGENT DATE ®o(J0(3,®( I hereby affirm that lam exempt from Contractor's License Law for the following mason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sate (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sate). [J I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply loan owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). [] I am exempt under Section _____________Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes I.1No 2.1 (have! have not) signed an application fora building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address! phone! contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name! address! phone /contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/address/phone/type of work): PROPERTY OWNER []AGENT DATE tP / (9009a(31711 VC003 SO?O®() 900 000-CM60013MO&I010000 PITIM098 ®1( Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration lbrm or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ®?O®&J W3000911B 4®(S I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address ZZIP(PaNiZOV IcerlifythatI havereadtheapplicationandstatethattheaboveinIbmiationisconectandthattheinfoimaliononthepIansisairabs. I agree tocompIywtthall Cityordinaness and State laws ielatingtobuildingconstnrction. I hereby authorize representative of the Cityof Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit is required forexcovotions over .50 deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Offdal under the provistonsof this Code shall expire by Imitation and become null and void if the building or york authorized by such permit is not commenced within 180day5 from the dateofsuth permitoriftheb ryorkauthorized bysuth tm domed at any time after the work iscommenced foraZeNofl (Secsbn 106.4.4 Uniform Building Code). 'APPLICANT'S SIGNATURE DATE / <-—' STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CE RTIFICATE O C CU PANCY•I I(Com mercia l P rojects• Fax (760) 602-8560. Email building@carlsbadca.Qov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICKUP: a CONTACT (Listed above) a OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) ASSOCIATED CB# MAIL TO: a CONTACT (Listed above) ci OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) NO CHANGE IN USE! NO CONSTRUCTION MAIL / FAX TO OTHER: CHANGE OF USE / NO CONSTRUCTION A!fAPPLICANTIS SIGNATURE DATE Permit Type: BLDG-Residential Application Date: 06/08/2016 Owner: CASEY KAMINSKl Work Class: Addition Issue Date: 11/17/2016 Subdivision: PARADISE ESTS UNIT# 1 Status: Closed - Finaled Expiration Date: 09/18/2017 Address: 1755 Valley P1 Carlsbad, CA 92008-1150 lVR Number: 715044 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 0311412017 0311412017 BLDG-16 Insulation 016282.2017 Passed Jonathan West Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03120/2017 0312012017 BLDG-17 Interior 016977.2017 Passed Jonathan West Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0611312017 0611312017 BLDG-Final 026068.2017 Passed Jonathan West Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Ll June 13,2017 - Page 2of2 Permit Type: BLDG-Residential Work Class: Addition Status: Closed Finaled Application Date: 06/08/2016 Owner: CASEY KAMINSKI Issue Date: 11/17/2016 Subdivision: PARADISE ESTS UNIT# 1 Expiration Date: 09/18/2017 Address: 1755 Valley Pt Carlsbad, CA 92008-1150 IVR Number: 715044 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 1112112016 1111812016 BLDG-21 001926.2016 Passed Peter Drelbelbis Complete UndergroundlUnderf loor Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 1210112016 12/01/2016 BLDG-11 003727.2016 Failed Jonathan West Reinspection Complete Foundation/FtglPier s(Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Withdraw inspection for 12-1-16 No 12/07/2016 1210712016 BLDG-1 I 004501-2016 Passed Jonathan West Complete Foundatlon/FtglPier $ (Reber) Checklist Item COMMENTS Passed BLDG-Building Deficiency Withdraw inspection for 12-1-16 Yes 01119/2017 01/1912017 BLDG-13 Shear 010330.2017 Passed Jonathan West Complete Panels/HD (Ok to wrap) BLDG-15 010331.2017 Passed Jonathan West Complete Roof/ReRoof (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0210912017 02/09/2017 BLDG-111 013190.2017 Passed Jonathan West Complete FoundationlFtg/Pier s (Reber) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 03/0312017 0310212017 BLDG-84 Rough 015230-2017 Passed' Jonathan West Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 03/13/2017 03/13/2017 BLDG-22 016338-2017 Passed Jonathan West Complete Sewer/Water Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes June l3,2017 Page lof2 Carlsbad 16-2221 July 6, 2016 \/ CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing. 'rojePermit: .........- Project Address:.J7YS A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder Ci. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please print) K'O15LR.. Il ttr2J Mailing Addresd1 ......L1it L_CA32SO Phone: I am: AOroperty Owner UProperty Owner's Agent of Record UArchitect of Record U Engineer of Record State of California Registration Number Expiration Date:___________________ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site Fabrication of building components, as prescribed in the statement of special inspections no on the a prov d p1 ns and, required by the California Buildin Code. Signature:1 11.0 Date: S. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder! owner-builder. Contractor's Company Name:,,,,_tLt%_ Please checir if you era Owner-Builder' Name: (please print) Mailing Address: J. Email' State of California Contractor's License Number: Expiration Date: I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. I will nrnvidn a final rponrt/Ipttnrin cnmnliancp with CRC Spctirin 1704.1.2 nriorto reaunatina final Signature - 6-45 Page 1 of 1 Rev, 08111 EsGil Corporation In (Partnersfiip with government for tBuiffing Safety DATE: August 8, 2016 JURISDICTION: Carlsbad PLAN CHECK NO.: 16-2221 PROJECT ADDRESS: 1755 Valley CT SET: IV U APPLICANT U JURIS. U PLAN REVIEWER U FILE PROJECT NAME: Addition & Remodel for Kaminski Residence LII The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. T-hp1anstransitted_heFewith will substrrntially iompIy-with the jurisdictions building codes when minor deficiencies identified below are resolved and checked by building department staff. J The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LII The applicant's copy of the check list has been sent to: fl EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steven Lutzke Telephone #: 760-468-3333 Date contacted: 8/8/16 (by: Abe) Email: steve.lutzke@yahoo.com Mail Telephone Fax In Person REMARKS: 1. Applicant to carry approved set of plans to the city. 2. Applicant to complete the City special inspection form. By: Abe Doliente Enclosures: EsGil Corporation 0 GA 0 EJ 0 MB 0 PC 8/8/16 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In tFartnership wit/i çovarnment for Bui(uing Safety DATE: July 20, 2016 JURISDICTION: Carlsbad PLAN CHECK NO.: 16-2221 PROJECT ADDRESS: 1755 Valley CT SET: III P1'LICANT i URIS. PLAN REVIEWER I FILE PROJECT NAME: Addition & Remodel for Kaminski Residence F-1 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Steven Lutzke LI EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steven Lutzke yate contacted:_j'7() (by)')C..y 1eMaiI Telephone Fax In Person El REMARKS: By: Abe Doliente EsGil Corporation El GA DEJDMB DPC Telephone #: 760-468-3333 Email: steve.lutzke©yahoo.com Enclosures: 7/14/16 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 16-2221 July 20, 2016 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold and underlined font are current. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. . PLANS All sheets of plans must be signed by the person responsible for their preparation. The structural portions and the structural calculations must be signed and sealed by the California state licensed engineer or architect responsible for their preparation. (California Business and Professions Code). Signatures will be verified before the plans are approved. On the cover sheet of the plans, specify any items that will have a deferred submittal (fire sprinklers/alarms, spiral stairs, etc.). Additionally, provide the following note on the plans: "Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official." There was no response received for this correction item. Item no. 9 is not complete. Carlsbad 16-2221 July 20, 2016 . GENERAL RESIDENTIAL REQUIREMENTS Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing in the walls/doors facing or containing bathtubs, showers, where the bottom exposed edge of the glazing is less than 60" above the standing surface. The window adiacent to the shower on the west wall must comply. This window must be labeled "T". See legend for tempered glass on sheet 3 of the plans. EXITS, STAIRWAYS, AND RAILINGS Provide spiral stairway details, per Section R311.7.10.1: If this is a deferred item, include it on the list. Refer to correction item 2. Otherwise, comply with items 9a thru 9d. The plans shown on sheet 7 of the plans is not comnlete. Minimum run is 714 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9-V2 inches. Maximum clear opening between risers is 4 inches. Minimum headroom is 6 feet 6 inches. The minimum clear width at and below the handrails shall be 26 inches. . FOUNDATION REQUIREMENTS Show minimum underfloor access of 16" x 24". Section R408.4. No response received. Responses to correction items 13 and 14 are not clear. Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of underfloor area. One such opening shall be within 3' of each corner of the building. Section R408.1. No response received. . FRAMING Completethe attached City Special Inspection Form at the end of this list. a) Expansion anchors. Periodic special inspection should be provided for anchors installed in hardened concrete. Section 1705.3. Carlsbad 16-2221 July 20, 2016 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at EsGil Corporation. Thank you. Carlsbad 16-2221 July 20, 2016 CITY OF CARLSBAD SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing. 'roject/Permit: Project Address:________________________________________ THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder 0. (If you checked as owner-builder you must also complete Section B of this agreement.) Name: (Please (First) (MI) (Lest) Mailing Address: Email Phone:________________________ I am: OProperty Owner oProperty Owners Agent of Record 0Architect of Record 0Engineer of Record State of California Registration Number Expiration Date:___________________ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signature: Date: CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder I owner-builder. Contractor's Company Name: Please check if you are Owner-Builder 0 Name: (Please print) (First) (Last) Mailing Address:____________________________________ Email: Phone: State of California Contractor's License Number:_____________ Expiration Date: I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. I will provide a final report/letter in compliance with CBC Section 1704.1.2 prior to requestina final inspection. Signature: Date: B.45 Page 1 of 1 Rev. 08/11 EsGil Corporation In (Partners/lip wit/i government for (Building Safety DATE: July 6, 2016 JURISDICTION: Carlsbad PLAN CHECK NO.: 16-2221 SET: II PROJECT ADDRESS: 1755 Valley CT PROJECT NAME: Addition & Remodel for Kaminski Residence U APPLICANT .-J URIS. U PLAN REVIEWER U FILE LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Steven Lutzke LI EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steven Lutzke i. pate c acted3'1 (fi (by't.) /V—P !1 ail Fax In Person LI REMARKS: By: Abe Doliente EsGil Corporation EJGA DEJDMB DPC Telephone #: 760-468-3333 Email: steve.lutzke©yahoo.com Enclosures: 6/30/16 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 16-2221 July 6, 2016 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold and underlined font are current. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. . PLANS All sheets of plans must be signed by the person responsible for their preparation. The structural portions and the structural calculations must be signed and sealed by the California state licensed engineer or architect responsible for their preparation. (California Business and Professions Code). Signatures will be verified before the plans are approved. On the cover sheet of the plans, specify any items that will have a deferred submittal (fire sprinklers/alarms, spiral stairs, etc.). Additionally, provide the following note on the plans: "Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official." There was no response received for this correction item. Carlsbad 16-2221 July 6, 2016 . GENERAL RESIDENTIAL REQUIREMENTS 8. Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: a) Glazing in the walls/doors facing or containing bathtubs, showers, where the bottom exposed edge of the glazing is less than 60" above the standing surface. The window adiacent to the shower on the west wall must comply. EXITS, STAIRWAYS, AND RAILINGS 9. Provide spiral stairway details, per Section R311.7.10.1: If this is a deferred item, include it on the list. Refer to correction item 2. Otherwise, comply with items 9a thru 9d. Minimum run is 744 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 944 inches. Maximum clear opening between risers is 4 inches. C) Minimum headroom is 6 feet 6 inches. d) The minimum clear width at and below the handrails shall be 26 inches. . FOUNDATION REQUIREMENTS 10. Provide a copy of the project soil report. The report shall include foundation design recommendations based on the engineer's findings and shall comply with Section R401.4. This is a requirement by the city. No response received. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). This goes with correction item 10. Show minimum underfloor access of 16" x 24". Section R408.4. No response received. Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of underfloor area. One such opening shall be within 3' of each corner of the building. Section R408.1. No response received. 'Carlsbad 16-2221 July 6, 2016 FRAMING 15. The plans shall indicate that special inspection will be provided for the following work. (CBC Chapter 17 and Section 107.2). Use the attached City Special Inspection Form at the end of this list. a) Expansion anchors. Periodic special inspection should be provided for anchors installed in hardened concrete. Section 1705.3. ELECTRICAL 17. For a single-family dwelling unit (and for each unit of a duplex), show that at least one receptacle outlet accessible at grade level will be installed outdoors at the front and back of the dwelling. CEC Article 210.52(E). This receptacle must be GFCI protected. None is shown on the electrical plans. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: YesU No U The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at EsGil Corporation. Thank you. Carlsbad 16-2221 July 6, 2016 Nr CITY OF CAR LSBAD SPECIAL INSPECTION AGREEMENT B-45 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca..gov In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed requires special inspection, structural observation and construction material testing. 'rojectlPermit: Project Address: THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNERIAUTHORIZED AGENT. Please check if you are Owner-Builder 0. (If you checked as owner-builder you mustalso complete Section B of this agreement) Name: (Please print) (FirSt) (Mi.) (Last) Mailing Address: Email____________________________________________________ Phone:_______________________ I am: UProperty Owner OProperty Owner's Agent of Record DArchitect of Record 0Engineer of Record State of California Registration Number Expiration Date:_________________ AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read, understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural observations, construction materials testing and off-site fabrication of building components, as prescribed in the statement of special inspections noted on the approved plans and, as required by the California Building Code. Signature: Date: CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the contractor I builder / owner-builder. Contractor's Company Name: Please check if you are Owner-Builder 0 Name: (Please print) (First) (Last) Mailing Address: Email: ______________________________________________________ Phone:__________________________ State of California Contractor's License Number: Expiration Date: I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on the approved plans; I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the building official; I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and frequency of reporting and the distribution of the reports; and I certify that I will have a qualified person within our (the contractor's) organization to exercise such control. I will arovide a final renort/letterin comnllance with CBC Section 1704.1.2 nrior to reauestinq final inspection. Signature: Date: B-45 Page 1 of 1 Rev. 08/11 EsGil Corporation In cPartners flip with government for Bui&ing Safety DATE: June 15, 2016 JURISDICTION: Carlsbad PLAN CHECK NO.: 16-2221 SET: I PROJECT ADDRESS: 1755 Valley CT PROJECT NAME: Addition & Remodel for Kaminski Residence O APPLICANT URIS. O PLAN REVIEWER O FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Steven Lutzke EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steven Lutzke 9e 7elenhone cted:.9'( 2 (by:'"..3_' 'fl all Fax In Person Eli REMARKS' By: Abe Doliente EsGil Corporation [I GA DEJDMB El PC Telephone #: 760-468-3333 Email: steve.lutzke©yahoo.com Enclosures: 6/9/16 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 16-2221 June 15, 2016 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. . PLANS All sheets of plans must be signed by the person responsible for their preparation. The structural portions and the structural calculations must be signed and sealed by the California state licensed engineer or architect responsible for their preparation. (California Business and Professions Code). 2. Specify on the Title Sheet of the plans the gross floor area of each element of this project, including dwelling, storage, and deck. Section R106.2. On the cover sheet of the plans, specify any items that will have a deferred submittal (fire sprinklers/alarms, spiral stairs, etc.). Additionally, provide the following note on the plans: "Submittal documents for deferred submittal items shall be submitted to the registered design professional in responsible charge, who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and that they have been found to be in general conformance with the design of the building. The deferred submittal items shall NOT be installed until their design and submittal documents have been approved by the building official." . FIRE PROTECTION Please indicate on the plans whether the existing residence has a fire sprinkler system installed. If so, then provide a note stating that any additions/alterations will be provided with an automatic residential fire sprinkler system. Section R313.2. Carlsbad 16-2221 June 15, 2016 In existing buildings, when alterations, repairs or additions requiring a permit occur (or when one or more sleeping rooms are added), the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R314.3.1. Specify on the plans that any existing smoke alarms that are more than 10 years old will be replaced. Section R314.3.2. When alterations, repairs or additions are proposed for dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), the dwelling unit shall be provided with carbon monoxide alarms located as required for new dwellings; the carbon monoxide alarms shall be interconnected and hard wired. Exception: Carbon monoxide alarms in existing areas need not be interconnected and hard wired where the alterations or repairs do not result in the removal of interior wall or ceiling finishes exposing the structure, unless there is an attic, crawl space, or basement available which could provide access for hard wiring and interconnection without the removal of interior finishes. Section R315.2. . GENERAL RESIDENTIAL REQUIREMENTS Glazing in the following locations should be shown on the plans as safety glazing material in accordance with Section R308.4: Glazing in the walls/doors facing or containing bathtubs, showers, where the bottom exposed edge of the glazing is less than 60" above the standing surface. The window adjacent to the shower and the tub must comply. Glazing where the bottom exposed edge is less than 36" above the plane of the adjacent walking surface of stairways, landings and ramps. Check the window by the closet next to the master bedroom. Glazing adjacent to the landing at the bottom of a stairway, where the glazing is less than 36" above the landing and within 60" horizontally of the bottom tread. Carlsbad 16-2221 June 15, 2016 EXITS, STAIRWAYS, AND RAILINGS 9. Provide spiral stairway details, per Section R311.7.10.1: Minimum run is 7-1/2 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9-'/2 inches. Maximum clear opening between risers is 4 inches. Minimum headroom is 6 feet 6 inches. The minimum clear width at and below the handrails shall be 26 inches. . FOUNDATION REQUIREMENTS 10. Provide a copy of the project soil report. The report shall include foundation design recommendations based on the engineer's findings and shall comply with Section R401.4. This is a requirement by the city. 11. If the soils engineer recommends that he/she review the foundation excavations, note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: The building pad was prepared in accordance with the soils report, The utility trenches have been properly backfilled and compacted, and The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report." 12. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). 13. Show minimum underfloor access of 16" x 24". Section R408.4. 14. Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of underfloor area. One such opening shall be within 3' of each corner of the building. Section R408.1. FRAMING 15. The plans shall indicate that special inspection will be provided for the following work. (CBC Chapter 17 and Section 107.2). Use the attached City Special Inspection Form. a) Expansion anchors. Periodic special inspection should be provided for anchors installed in hardened concrete. Section 1705.3. Carlsbad 16-2221 June 15, 2016 . ELECTRICAL Include on the plans the following specifications for electrical devices installed in dwellings: CEC Article 210 & 406 a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all receptacles in a dwelling). For a single-family dwelling unit (and for each unit of a duplex), show that at least one receptacle outlet accessible at grade level will be installed outdoors at the front and back of the dwelling. CEC Article 210.52(E). This receptacle must be GFCI protected. Show at least one wall switch-controlled lighting outlet to be installed in every habitable room; in bathrooms, hallways, stairways, attached garages, and detached garages with electric power; and at the exterior side of outdoor entrances or exits. At interior stairways show 3-way switching for lighting outlets at each floor level where there are six or more steps. CEC Article 210.70(A). . PLUMBING Note on the plans that "combustion air for fuel burning water heaters will be provided in accordance with the Plumbing Code". Dimension on the plans the 30" clear width required for the water closet compartment and the 24" clearance required in front of the water closet. CPC 402.5. Provide a note on the plans: The control valves in showers, bathtubs, and bidets must be pressure balanced or thermostatic mixing valves. CPC Sections 408, 409, 410. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, kitchen faucets may not exceed 1.8 GPM, lavatories are limited to 1.5 GPM, and showerheads may not exceed 2.0 GPM of flow. CPC Section 403 and 408. Carlsbad 16-2221 June 15, 2016 . RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code which became effective January 1, 2011 and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. CGC Section 101.3. The Standards apply to newly constructed residential buildings, along with additions/alterations that increase the building's conditioned area, volume or size. CGC Section 303.1.1. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. Storm water drainage/retention during construction. Note on the plans: Projects which disturb less than one acre of soil shall manage storm water drainage during construction by one of the following: A. Retention basins. B. Where storm water is conveyed to a public drainage system, water shall be filtered by use of a barrier system, wattle or other approved method. CGC 4.106.2. Grading and paving. Note on the plans that site grading or drainage system will manage all surface water flows to keep water from entering buildings (swales, water collection, French drains, etc.). CGC 4.106.3. Exception: Additions not altering the drainage path. Recycling. Note on the plans that a minimum of 50% of construction waste is to be recycled. CGC 4.408.1. Recycling. Note on the plans that the contractor shall submit a Construction Waste Management Plan to the jurisdiction agency that regulates waste management, per CGC 4.408.2. Operation and maintenance manual. Note on the plans that the builder is to provide an operation manual (containing information for maintaining appliances, etc.) for the owner at the time of final inspection. CGC 4.410.1. Note on the plans that the gas fireplace(s) shall be a direct-vent sealed- combustion type. Woodstove or pellet stoves must be US EPA Phase II rated appliances. CGC 4.503.1. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed, and mechanical equipment is to be covered. CGC 4.504.1. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC 4.504.2. Carlsbad 16-2221 June 15, 2016 Interior moisture control. Note on the plans that the moisture content of wood shall not exceed 19% before it is enclosed in construction. The moisture content needs to be certified by one of 3 methods specified in Section 4.505.3. Building materials with visible signs of water damage should not be used in construction. The moisture content must be determined by the contractor by one of the methods listed in CGC 4.505.3. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star rated, vented directly to the outside and controlled by a humidistat. CGC 4.506.1. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. . MISCELLANEOUS Show the RA-2 (2 x 10 @ 24" o.c.) and RA-3 (2 x 10 @ 24" o.c.) as called out on pages 3, 7 & 8 of the structural calculations. Refer to sheet S-5 of the plans. Show RA-4 (double 2 x 10 @ 24" 0.c.) as called out on pages 3 and 10 of the structural calculations. Refer to sheet S-5 of the plans. Recheck HDR-1. Architectural plans show the existing opening is 8 ft and noted to use the existing header. Structural calculations used 5 ft span for the header size. If the existing header is only 4 x 4, recheck the structural calculations. Use 8 ft instead of 5 ft for the span. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes El No U Carlsbad 16-2221 June 15, 2016 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at EsGil Corporation. Thank you. Carlsbad 16-2221 June 15, 2016 [DO NOT PAY — THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 16-2221 PREPARED BY: Abe Doliente DATE: June 15, 2016 BUILDING ADDRESS: 1755 Valley CT BUILDING OCCUPANCY: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Addition 730 166.81 121,771 Storage 321 36.40 Deck 325 19.71 6,406 Air Conditioning Fire Sprinklers TOTAL VALUE 139,861 Jurisdiction Code Icb By Ordinance Bldg. Permit Fee by Ordinance v Plan Check Fee by Ordinance V I $768.061 I $499.241 Type of Review. Rl Complete Review 0 Structural Only Repetitive Fee [1 Other I Repeats El Hourly EsGil Fee Hr. I $430.11! Comments: in addition to the above tee, an aaaitionai Tee OT 'ii is aue II/ nour $86/hr.) for the Ca 3reenjeyLey. Sheet I of I macvaiue.doc + PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 06/14/2016 PROJECT NAME: KAMINSKI FAMILY ADDITION PROJECT ID:CB16-2221 PLAN CHECK NO: 1 SET#: 1 ADDRESS: 1755 VALLEY P1 AI'N: 2050803300 VALUATION: $136,585 SCOPE OF WORK: 730 SF ADDITION & 325 SF ROOF DECK AND 231 SF STORAGE This plan check review is complete and has beenAPPROVED by: LAND DEVELOPMENT ENGINEERING DIVISION ~APInal Inspection by Construction Management & Inspection DiviSion is required: Yes El No X This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: STEVE.LUTKE@YAHOO.COM To determine status by one of the divisions listed below, please contact 760-602-2719. LAND DEVELOPMENT 1 - 760602-2750 F], Chris Sexton F-1 Chris Glassen Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carlsbadca.gov Christopher.Glassen@carlsbadca.gov Gregory.Ryan@carlsbadca.gov FT Gina Ruiz. F1 Linda Ontiveros F] Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov ValRay Nelson, F X-1 F] Dominic Fieri 760-602-2741 760-602-4664 ValRay.Marshall@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: ri I-I KAMINSKI FAMILY ADDITION PLAN CHECK NO# 1 Outstanding issues are marked with EZI . Items that conform to permit flLU1JN requirements are marked with 121 or have intentionally been left blank. 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. E3 E2J North arrow EJ LZJ Existing & proposed structures EJ LJ Existing street improvements EJ EZJ Property lines (show all dimensions) J L21 Easements EJ Right-of-way width & adjacent streets Show: Driveway widths LJ EJ Existing or proposed sewer lateral EJ EJ Existing or proposed water service EJ EJ Submit on signed approved plans: DWG No. Show on site plan: LI Drainage patterns and proposed site elevations. Show all high points. E1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". Existing & proposed slopes and topography =Size, location, alignment of existing or proposed sewer and water service(s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. LJ Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: F,7-1 Site address 121 Assessor's parcel number Legal description/lot number For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. LJ IJ Show all existing use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No.: LOTS MAP 3691 Subdivision/Tract: PARADISE ESTS UNIT #1 Reference No(s): E-36 Page 2 of 6 REV 6/01/12 , r Page 3of6 - - C4M1d'W2, S KAMINSKI FAMILY ADDITION PLAN CHECK NO # 1 DISCRETIONARY APPROVAL COMPLIANCE NON ii Project does not comply with the following engineering conditions of approval for project no.: CONFORMING PERMIT DEDICATION REQUIREMENTS Dedication for all street rights-of-way adjacent to the building site and any storm drain or N/A utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 24.000.00 , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: IMPROVEMENT REQUIREMENTS All needed public improvements upon and adjacent to the building site must be constructed PLEASE at time of building construction whenever the value of the construction exceeds PROVIDE A $120.000.00, pursuant to Carlsbad Municipal Code Section 18.40.040. DETAILED Public improvements required as follows: COST ESTIMATE FOR LABOR AND MATERIALS OF JUST THE Construction of the public improvements must be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant ADDITION deed on the property and processing fee, so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the city prior to issuance of a building permit. EJ EJ Future public improvements required as follows: :. .0'00000 4A Ai/W7JJ2A/ fd - E36 i OU& /0Jà ,vatãa&I I A 1A. 2 ae b. KAMINSKI FAMILY ADDITION PLAN CHECK NO # 1 GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. E:J=Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING" Grading Permit required. NOTE: The grading permit must be issued and rough grading approval obtained prior to issuance of a building permit. EJ EJ Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector The inspector will then provide the enineering counter with a release for the building permit. LJILJ No grading permit required. =1= Minor Grading Permit required. See additional comments for project- specific requirements. MISCELLANEOUS PERMITS RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. J Right-of-way permit required for: *ANY WORK BEING DONE WITHIN THE PUBLIC RIGHT OF WAY* E-36 Page 4 of 6 REV 6/01/12 071 I. KAMINSKI FAMILY ADDITION PLAN CHECK NO # 1 7. STORM WATER Construction Compliance E EJ Project Threat Assessment Form complete. I EJ Enclosed Project Threat Assessment Form incomplete. IM EJ Requires Tier I Storm Water Pollution Prevention Plan (E-29). Please complete attached form and return (SW ) EJ Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-Development (SUSMP) Compliance Storm Water Standards Questionnaire. EJ LJ Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. Indicate areas of impervious surfaces (patioswalkway, etc. ) and pervious areas (landscaping). L1 EJ Project needs to incorporate low impact development strategies throughout in one or more of the following ways: J Rainwater harvesting (rain barrels or cistern) J Vegetated Roof EJ Bio-retentions cell/rain garden El Pervious pavement/payers EJ Flow-through planter/vegetated or rock drip line EJ Vegetated swales or rock infiltration swales IJ Downspouts disconnect and discharge over landscape J Other: E-36 Page 50f6 REV 6/01/12 KAMINSKI FAMILY ADDITION PLAN CHECK NO # 1 8. WATER METER REVIEW Domestic (potable) Use TOTAL 2210SF What size meter is required? DOES NOT i: Where a residential unit is required to have an automatic fire extinguishing system, the minimum meter size shall be a 1" meter. MEET NOTE: the connection fee, SDCWA system capacity charge and the THRESHHOLD water treatment capacity charge will be based on the size of the meter TO UPGRADE necessary to meet the water use requirements. EJ jJ For residential units the minimum size meter shall be 5/8", except where the residential Unit is larger than 3,500 square feet or ona lot larger than one quarter (1/4) acre where the meter size shall be %". 9. FEES JEJ EJE Required fees have been entered in building permit. Drainage fee applicable Added square feet Added square footage in last two years? LJ yes EJ no Permit No. Permit No. Project built after 1980 yes r no Impervious surface >50% E] yes Jno Impact unconstructed facility M yes El no Fire sprinklers required Jyes Jno (is addition over 150' from center line) Upgrade yes Eno No fees required 10. ADDITIONAL COMMENTS Attachments: [j Engineering Application [] Storm Water Form [] Right-of-Way Application/Info. [] Reference Documents E-36 . Page 6of6 REV 6/01/12 '"Fee Calculation Worksheet ENGINEERING DIVISION Prepared by: VALRAY NELSON Date: 06/1412016 GEO DATA: LFMZ: I B&T: Address: 1755 VALLEY PL Bldg. Permit #: CB162221 Fees Update by: Date: Fees Update by: Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: Types of Use: Sq.Ft./Units EDU's: Types of Use: . Sq.Ft./Units EDU's: ADT CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units ADT's: Types of Use: Sq.Ft./Units ADT's: Types of Use: Sq.Ft./Units ADT's: Types of Use: Sq.Ft./Units ADT's: FEES REQUIRED: Within CFD: DYES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) IZINO 1. PARK-IN-LIEU FEE:DNW QUADRANT ONE QUADRANT OSE QUADRANT [3W QUADRANT ADT'S/UNITS: X FEE/ADT: I 23RAFFIC IMPACT FEE: ADT'S/UNITS: X FEE/ADT: I BRIDGE & THOROUGHFARE FEE: JDIST. #1 JDIST.#2 EDIST.#3 (USE SANDAG)ADT'S/UNITS X FEE/ADT: I $ FACILITIES MANAGEMENT FEE ZONE: ADT'S/UNITS: I X FEE/SQ.FT./UNIT: I SEWER FEE EDU's X FEE/EbU: I BENEFIT AREA: EDU's X FEE/EDU: I DRAINAGE FEES: A PLDA: EIHIGH F-1 MEDIUM r7JLOW ACRES: .21 X FEE/AC: 6209 $ 1303.89 POTABLE WATER FEES: UNITS I CODE I CONN. FEE I METER FEE I SDCWA FEE I TOTAL ***This may not represent a comprehensive list of fees due for this project. Please contact the Building division at (760) 6022719 for a complete listing of fees BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Control Sediment Control BMPs Tracking Non-Storm Water Waste Management and Materials BMPs Control BMPs Management BMPs pollution Control BMPs S S C — 0Co . . 0 C Best Management Practice .i • . , B (BMP)Description-3 at ca ca 8 roB. — 0 C 2 ro, 5to o5 m 0 er on i il ö t2 in> in ii5or era- a.& a- > o €Wc3 CAsoAoeslgnatlon-3 p- or .. .n w '7 ¶ 7 '7 't '7 consliuctlonAclivfly to ZZZZ Groding/SoilDisturbance Trenchingitxcovatton Stockpiling Dnlling/Boring - Concrete/AspholtSawcutting --- -- -- - - - - Concrete Flotwork 1.1 IA ipelnstollotion rtorWork A posal oyDownArea MointenanceondFuolng SubstonceUse/Storoge - - - - - - - - - - - - - - - - - - - - - - - - - - - Dewatering - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SiteAccess Across Dirt I _Other(Iist): Instructions: Check the box to the left of all applicable construction activity (first column) expected to occur during construction. Located along the top of the BMP Table is o list of BMPs with 1t5 corresponding California Stormwoter Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row intersects with the BMP column. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project. STORM WATER COMPLIANCE FORM TIER I CONSTRUCTION SWPPP E-29 CB Ro?Z2_t SWo -Z19 STORM WATER POLLUTION PREVENTION NOTES ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN IS EMINENT. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SA11SFACIION OF THE CITY INSPECTOR AFTER EACH RUN—OFF PRODUCING RAINFALL THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE AVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGATE. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST BE INSTALLED AND MAINTAINED. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED TO ENSURE COMPLIANCE NTH CITY STORM WATER QUALITY REGULATIONS. OWNERS CERTIFICATE: I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION AC11VI11ES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOBILIZATION Of POLLUTANTS SUCH AS SEDIMENT AND TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES, COMPLY NTH THIS CITY APPROVED TIER 1 CONSTRUCTION SYfPPP THROUGHOUT THE DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE CONSTRUCTION WORK IS COMPLETE AND APPROVED BY NE ITY OF CARLSBAD. J(,a, OWNER(S) AGEN < OWNER(S)/OWNENT NAME (SIGNATURE) DATE E-29 SHOW THE LOCATIONS OF ALL CHOSEN BMPs ABOVE ON THE PROJECTS SITE PLAN/EROSION CONTROL PLAN. SEE THE REVERSE SIDE OF THIS SHEET FORA SAMPLE EROSION CONTROL PLAN. Page 1 of 1 PROJECF INFORMATION Site Address:_'P \ Assessors Parcel Number Emergency Contact: Name: C - 24 Hour Phon7(.C.~L# 1. Construction Threat to Storm Water Quality (Check Box) 0 MEDIUM rLOW REV 02/16 lop : ~5-~ /t xx o xx xx xx SCALE: LM HMLL-)~\ T7 1212 BROW SON 4'SMRM ~ FE 17.88 LIMM UiNC Mr PARMO SERMOW LEGEND UNE , , DESCRIPTION e DWG.NO. SYMBOL QUANTITY Ram PROPERTY LINE N454545 *N IF MEM AIM MAUED SILT FENCE SE- flEE COA57RUCM WE IS MOVASKM PROJECT FIBER ROLL SE-5 —x—x—x—x— ISLETS PER SE-JO. TI7CAL PRESERVAIJON OF EXISTING EC-2 _________________ PRESERMOON OF INLET PROIECIION SE- JO SEWAD EC-2. Mck FEC GRAVEL BAG BERM/BARRIER SE-6 (DC) DIRECTION/COURSE OF FLOW - - - H)VRAULIC MULCH/H)VROSEED EC-I. EC-4 STABILIZED CONSTRUCTION ENIR4NCE JR—I AMTERMS DELIVERY AND STORAGE I TEMPORARY TRASH/SOLID WASTE WM-5 HAZARDOUS AND CONCRETE WM-6, WM-8 I \. \ WASTE £WIAGFJAENT swIr.4JIY WASTE WM-9 ),-9 \ \ (PORTABLE TOILET) - \ \ -STANDARD DRAWINGS (SE-5, FBi-B, ETC.) CAN BE FOUND AT THE CAUFORN14 STORMWATER QLL4UTY ASSOCIATION (CASQA) WEBSIIE http://www.ccbmphandbooks.com/ £LW LL ADOWN F.31O8 CA (city of Carlsbad DETERMINATION OF PROJECT'S SWPPP TIER LEVEL AND CONSTRUCTION THREAT LEVEL E-32 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov I'm applying for: 0 Grading Prr 1it l€uiIding Permit 0 Right-of-way permit 0 Other Project Name: _C,a,$c4 'M.&Project ID: DWG #ICB#_____________ Address: APN2..00cn Disturbed Area: Ac Section 1: Determination of Project's SWPPP Tier Level SWPPP (Check applicable criteria and circle the corresponding SWPPP Tier Level, then go to section 2) Tier Level Exempt - No Threat Proiect Assessment Criteria My project is in a category of permit types exempt from City Construction SWPPP requirements. Provided no significant grading proposed, pursuant to Tablel, section 3.2.2 of Storm Water Standards, the following permits are exempt from SWPPP m.!............................................................................................................... Exempt > Electrical > Patio > Mobile Home > Plumbing > Spa (Factory Made) Fire Sprinkler , > Mechanical , > Re-Roofing > Sign > Roof-Mounted Solar Array I Tier 3- Significant Threat Assessment Criteria — (See Construction General Permit (CGP) Section l.B)* LI My project includes construction or demolition activity that results in a land disturbance of equal to or greater than one acre including but not limited to clearing, grading, grubbing or excavation; or, LI My project includes construction activity that results in land disturbance of less than one acre but the construction activity is part of a larger common plan of development or the sale of one or more acres of disturbed land surface or, LI My Project is associated with construction activity related to residential, commercial, or industrial Tier 3 development on lands currently used for agriculture; or LI My project is associated with construction activity associated with Linear Underground/overhead Projects (LUP) including but not limited to those activities necessary for installation of underground and overhead linear facilities (e.g. conduits, substructures, pipelines, towers, poles, cables, wire, towers, poles, cables, wires, connectors, switching, regulating and transforming equipment and associated ancillary facilities) and include but not limited to underground utility mark out, potholing, concrete and asphalt cutting and removal, trenching, excavation, boring and drilling, access road, tower footings/foundation, pavement repair or replacement, stockpile/borrow locations. LI Other per CGP Tier 2- Moderate Threat Assessment Criteria: My project does not meet any of the Significant Threat Assessment Criteria described above and meets one or more of the following criteria: LI Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or, LI Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria: Tier 2 located within 200 feet of an environmentally sensitive area or the Pacific Ocean; and/or, disturbed area is located on a slope with a grade at or exceeding 5 horizontal to I vertical; and/or disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse; and/or construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through Apr. 30). Tier 1- Low Threat Assessment Criteria My project does not meet any of the Significant or Moderate Threat criteria above, is not an exempt permit type per above and the project meets one or more of the following criteria: Tier I results in some soil disturbance; and/or includes outdoor construction activities (such as roof framing, saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling) * Items listed are excerpt from CGP. CGP governs criteria for triggers for Tier 3 SWPPP. Developer/owner shall confirm coverage under the current CGP and any amendments, revisions and reissuance thereof. E-32 Page 1 of 2 Rev. 2/16/16 SWPPP Section 2: Determination of Project's Construction Threat Level Ter (Check applicable criteria under the Tier Level as determined in section 1, circle Construction V Level the corresponding Construction Threat Level, then complete the Threat Level signature block below) Exempt - Not Applicable - Exempt Tier 3— High Construction Threat Assessment Criteria: My Project meets on6 or more of the following: U Project site is 50 acres or more and grading will occur during the rainy season o Project site is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA High Li Soil at site is moderately to highly erosive (defined as having a predominance of soils Tier 3 with USDA-NRCS Erosion factors kf greater than or equal to 0.4) O Site slope is 5 to I or steeper 0 Construction is initiated during the rainy season or will extend into the rainy season (Oct. I - April 30). U Owner/contractor received a Storm Water Notice of Violation within past two years Tier 3— Medium Construction Threat Assessment Criteria Medium U All projects not meeting Tier 3 High Construction Threat Assessment Criteria Tier 2— High Construction Threat Assessment Criteria: My Proiect meets one or more of the following: U Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA LI Soil at site is moderately to highly erosive (defined as having a predominance of soils High with USDA-NRCS Erosion factors kf greater than or equal to 0.4) Tier 2 Li Site slope is 5 to I or steeper LI Construction is initiated during the rainy season or will extend into the rainy season (Oct. I-Apr. 30). U Owner/contractor received a Storm Water Notice of Violation within past two years U Site results in 10,000 sq. ft. or more of soil disturbance Tier 2— Medium Construction Threat Assessment Criteria Medium Li My project does not meet Tier 2 High Threat Assessment Criteria listed above Tier I - Medium Construction Threat Assessment Criteria: My Proiect meets one or more of the following: Li Owner/contractor received a Storm Water Notice of Violation within past two years 'Site results in 500 sq. ft. or more of soil disturbance Medium e Tier I Construction will be initiated during the rainy season or will extend into the rainy season (Oct.1-April 30) Tier 1 - Low Construction Threat Assessment Criteria 0 Low U My project does not meet Tier I Medium Threat Assessment Criteria listed above certify to the best of my knowledae that the above statements are true and correct I will orenare and submit an annrnnriate tier 1pvpl.qWPPPqq rietermined ahnve prepared in accordance with the City SWPPP Manual. I understand and acknowledge thatl must adhere to and comply with the storm water best management practices pursuant to Title 15 of the Carlsbad Municipal Code and to City Standards at all times during construction activities for the permit type(s) checked above. The City Engineer/Building Official may authorize minor variances from the Construction Threat Assessment Criteria in special circumstances where it can be shown that a lesser or higher SWPPP Tier Level is warranted. Owner/Owner's Authorized Agent Name: Title: .9~~ I( J~~L \ SJJ4 Owner/Owner's Authorized Agent Signre: Date: City Concurrence: (For City Use Only) Yes No By: Date: Project ID: E-32 Page 2 of 2 Rev. 2/16/16 (city of Cd lsbad STORM WATER STANDARDS QUESTIONNAIRE E-34 Develooment Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov INSTRUCTIONS: To address post-development pollutants that may be generated from development projects, the City requires that new development and significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMP's) into the project design per Carlsbad BMP Design Manual (BMP Manual). To view the BMP Manual, refer to the Engineering Standards (Volume 5). This questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision, discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to STANDARD PROJECT' requirements or be subject to 'PRIORITY DEVELOPMENT PROJECT' (131313) requirements. Your responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by you, this will result in the return of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the City. If you are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, please seek assistance from Land Development Engineering staff. A completed and signed questionnaire must be submitted with each development project application. Only one completed and signed questionnaire is required when multiple development applications for the same project are submitted concurrently. PROJECT INFORMATION PROJECT NAME: PROJECT ID: The project is (check one): 0 New Development 0 Redevelopment The total proposed disturbed area is: ft2 ( ) acres The total proposed newly created and/or replaced impervious area is: ft2 C_) acres If your project is covered by an approved SWQMP as part of a larger development project, provide the project ID and the SWQMP # of the larger development project: Project ID: SWQMP #: Then, go to Step I and follow the instructions. When completed, sign the form at the end and submit this with your application to the City. E-34 Page 1 of 4 REV 02/16 STEP I TO BE COMPLETED FOR ALL PROJECTS To determine if your project is a "development project", please answer the following question: YES NO Is your project LIMITED TO routine maintenance activity and/or repair/improvements to an existing building or structure that do not alter the size (See Section 1.3 of the BMP Design Manual for guidance)? *.myv If you answered "yes" to the above question,.provide justification below then Go to step 5, mark the third box stating project is not a 'development project' and not subject to the requirements of the BMP manual" and complete applicant information. Justification/discussion: (e.g. the project includes only interior remodels within an existing building): If you answered "no" to the above question, the project is a 'development project', go to Step 2. - STEP TO BE COMPLETED FOR ALL DEVELOPMENT PROJECTS To determine if your project is exempt from PDP requirements pursuant to MS4 Permit Provision E.3.b.(3), please answer the following questions: Is your project LIMITED to one or more of the following: YES NO 1. Constructing new or retrofitting paved sidewalks, bicycle lanes or trails that meet the following criteria: a) Designed and constructed to direct storm water runoff to adjacent vegetated areas, or other non- erodible permeable areas; . Designed and constructed to be hydraulically disconnected from paved streets or roads; Designed and constructed with permeable pavements or surfaces in accordance with USEPA Green Streets guidance? 2. Retrofitting or redeveloping existing paved alleys, streets, or roads that are designed and constructed \, J in accordance with the USEPA Green Streets guidance? 3. Ground Mounted Solar Array that meets the criteria provided in section 1.4.2 of the BMP manual? If you answered "yes" to one or more of the above questions, provide discussion/justification below, then Go to step 5, mark the second box stating "my project is EXEMPT from PDP ..." and complete applicant information. Discussion to justify exemption (e.g. the project redeveloping existing road designed and constructed in accordance with the USEPA Green Street guidance): If you answered "no" to the above questions, your project is not exempt from PDP, go to Step 3. E-34 Page 2 of 4 REV. 02/16 PLANNING DIVISION Development BUILDING PLAN CHECK Services 40*)k, Planning Division CITY OF REVIEW CHECKLIST 1635 Faraday Avenue CARLSBAD P-28 (760) 602-4610 www.carlsbadca.eov DATE: 7/14/2016 PROJECT NAME: SFR ADDITION PROJECT ID: PLAN CHECK NO: CB162221 SET#: 3 ADDRESS: 1755 VALLEY PL APN: This plan check review is complete and has been APPROVED by the Planning Division. By: Veronica Morones A Final Inspection by the Planning Division is required Yes Z No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: steve.Iutzke@yahoo.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton Chris Glassen Greg Ryan 760-602-4624 760-602-2784 760-602-4663 Chris.Sexton@carIsbadca.gov Christor,her.GIassen@carIsbadca.ov Greeorv.Ryan@carIsbadca.gov Gina Ruiz ValRay Marshall Cindy Wong 760-602-4675 760-602-2741 760-602-4662 Gina.Ruiz@carIsbadca.gov VaIRay.MarshaII@carIsbadca.gov Cynthia.Wong@carlsbadca.gov Veronica Morones LII Linda Ontiveros Dominic Fieri 760-602-4619 Veronica.Morones@carIsbadca.gov 760-602-2773 Linda.0ntiveros@carIsbadca.ov 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: BAY & GARDEN WINDOWS ARE OUTSIDE OF SETBACKS; FENCE DENOTED AS VON PLANS P-28 Page 1 of 4 07/11 A PLANNING DIVISION Development Services I BUILDING PLAN CHECK Planning Division CITY OF REVIEW CHECKLIST 1635 Faraday Avenue (760) 602-4610 CARLSBAD P-28 Plan Check No. CB162221 Address 1755 VALLEY PL Date 7/14/2016 Review #3 Planner Veronica Morones Phone (760) 6024619 APN: Type of Project & Use: SFR ADDITION Net Project Density: DU/AC Zoning: 114 General Plan: R-4 Facilities Management Zone: I CFD (in/out) #_Date of participation: Remaining net dev acres:_____ (For non-residential development: Type of land use created by this permit: REVIEW #: 1 2 3 Legend IZI Item Complete LI Item Incomplete - Needs your action I 0 Environmental Review Required: YES 0 NO II TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: 0 Discretionary Action Required: YES 0 NO 0 TYPE APPROVAL/RESO.NO. DATE___ PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Z IZI 0 Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES 0 NO CA Coastal Commission Authority? YES 0 NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): 0 Habitat Management Plan Data Entry Completed? YES 0 NO 0 If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (NP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Z 0 • Inclusionary Housing Fee required: YES 0 NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES 0 NO 0 (NP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) • P-28 Page 2 of 4 07/11 PLANNING DIVISION 404' h> BUILDING PLAN CHECK Development Services Planning Division CITY OF REVIEW CHECKLIST 1635 Faraday Avenue. CARLSBAD P-28 (760) 602-4610 www.carlsbadca.Eov 0 Housing Tracking Form (form P-20) completed: YES 0 NO E] N/A Site Plan: IZI 0 Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number.. City Council Policy 44— Neighborhood Architectural Design Guidelines Z 0 1. Applicability: YES 0 NO Z C9 0 0 2. Project complies: YES 0 NOD Zoning: R-1: STRUCTURE IS EXISTING NONCONFORMING-REQUIRES A NONCONFORMING CONSTRUCTION PERMIT PER SECTION 21.48.050. 0 0 0 1. Setbacks: Front: Required Shown Interior Side: Required Z Shown 4'6" 0 garage Street Side: Required Shown Rear: Required j.' Shown j.' Top of slope: Required Shown Z 0 0 2. Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown 0 0 0 3. Lot Coverage: PLEASE INCLUDE SPIRAL STAIRS, ORIEL WINDOWS, ROOF EAVES THAT PROTRUDE MORE THAN 30", AND FRONT PATIO (IF COVERED OR OVER 30" IN HEIGHT) IN LOT COVERAGE CALCULATION Required MAX 40% Shown IZI 0 0 4. Height: Required 24' < 3:12 Shown 19' 3:12 & < 3:12 0 5. Parking: Spaces Required 2-CAR GARAGE Shown 2-CAR GARAGE (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown P-28 Page 3 of 4 07/11 PLANNING DIVISION BUILDING PLAN CHECK Development Services <4 70b> Planning Division CITY OF REVIEW CHECKLIST 1635 Faraday Avenue (760) 602-4610 CARLSBAD P28 0 6. Floor Area Ratio: Required Shown O 0 0 Additional Comments: 1. PER SECTION 21 .48.050 OF C.M.C. A NONCONFORMING CONSTRUCTION PERMIT IS REQUIRED AS EXPANSION IS GREATER THAN 40% (604 SF) OF STRUCTURE FLOOR SPACE (AND GREATER THAN 640SF). STRUCTURE IS CONSIDERED NONCOFORMING BY SUBSTANDARD YARDS OF GARAGE, WHICH IS ATTACHED TO THE RESIDENCE, THEREBY ENCUMBERING EXISTING RESIDENCE EXPANSION; PLEASE CHANGE LOT COVERAGE TO REFLECT ACCURATE AMOUNT LISTED IN NUMBER 3; PLEASE SHOW SPIRAL STAIRCASE ON SITE PLAN. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE P.28 Page 4 of 4 07/11 City of Carlsbad CERTIFICATION OF SCHOOL FEES PAID B-34 Develonment Services Building Department 1635 Faraday Avenue 760-6022719 www.carlsbadca.gov This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit. The City will not issue any building permit without a completed school fee form. Project Name Kaminski residence Building Permit Plan Check Number CB162221 Project Address: 1755 Valley P1. A.P.N 205-080-33-00 Project Applicant Casey & Ann Kaminski (Owner Name) Project Description: Addition Building Type Residential Residential: NEW DWELLING UNIT(S) 730 Square Feet of Living Area in New Dwelling/s Second Dwelling Unit: Square Feet of Living Area in SDU Residential Additions: Net Square Feet New Area Commercial/Industrial: Net Square Feet New Area City Certification of Applicant Information: Jvt.etAltr Date 08/08/2016 L DISTRICTS WITHIN THE Carlsbad Unified School District J Vista Unified School District D San Marcos Unified School District 6225 El Camino Real 1234 Arcadia Drive 255 Pico Ave Ste. 100 Carlsbad CA 92009 (760-331-5000) Vista CA 92083 (760-726-2170) xt San Marcos, CA 92069 (760-290-2649) 2222 Contact: Nancy Dolce (By Appt. Only) U Encinitas Union School District- U San Dieguito Union High School District-By Appointment Only By appointment only 684 Requeza Dr. 101 South Rancho Santa Fe Rd Encinitas, CA 92024 Encinitas, CA 92024 (760-753-6491 x 5514) Certification of Applicant/Owners. The person executing this declaration (Owner) certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or that the person executing this declaration is authorized to sign on behalf of the Owner. ..........- Signature: / . a_2_.__-7• Date: 7/2//ce B-34 Page 1 of 2 Rev. 03/09 SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school district(s)) THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. SCHOOL DISTRICT: The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building permits for this project. SIGNATURE OF AUTHORIZED SCHOOL DISTRICT OFFICIAL TITLE NAME OF SCHOOL DISTRICT DATE PHONE NUMBER * C V Y\\C-Y\kL. CARLSBAD UNIFIED SCHOOL DISTRICT 6225 EL CAMINO REAL CARLSBADJ CA 92009 q— (, r-t16 331-s6 B-34 Page 2 of 2 Rev. 03/09 D U N N S AV 0 1 E INC. 908 S. CLEVELAND T. STRUCTURAL ENGINEERING OCEANSIDE. CA 9205 7.966.6355 PH. 780.96.636OFX. O94 U RFDSI . CØP.i EMAIL July 9, 2016 Carlsbad Building Department do Mr. Casey Kaminski cc: Steve Lutzke, Designer 1755 Valley Place Ph: (760) 468-3333 Carlsbad, CA. 92008 E-mail: steve.lutzke(äyahoo.com Ph: (760) 586-2451, Email: ckam inskiäsoapmat.com Reference: Kaminski Remodel -Soil Observation Letter for 1000psf soil bearing Dear Mr. Kaminski & Carlsbad Building Official: We are providing you with this letter to justify the allowable soil bearing for the reference project. The project consists of a residential remodel located at 1755 Valley P1., Carlsbad, California 92008. Will Fosse of the Carlsbad Building Department indicated that a signed letter by a registered professional to establish the allowable soil bearing of 1000 psf based on a visual inspection in lieu of the soils report required by Esgil plan check items 10 & 12. On July 8, 2016, a hole was dug at a location about 10 feet from the existing residence rear west corner. As the hole approached 8 inches deep, the soil became noticeably harder, approaching that of "hardpan", so the digging was terminated. - I am satisfied that the existing soils are more than adequate to use 1000 psf as a maximum allowable soil bearing pressure (with a one third increase for transitory loads). DSI will revise our calculations to reflect the above value in lieu of the previously used 1500 psf and make any adjustments to the footing sizes as needed as part of the plan check resubmittal. If you have any questions, please do not hesitate to contact our office. The opportunity to provide this service is appreciated. Sinceely/ DUN J<I 'AVOIE C. /4 Rh1. Savy, P (C46423)* * Lk!dnse , pd'mb as registered with the Board of Práfessional Engineers and Land Surveyors. / City of Carlsbad Permit No: Valuation Worksheet Building Division T'of4Wk WAifWka W MGltilië 'LUIEliiiiiiiiiiililillillill SFD and Duplexes $139.52 $0.00 Residential Additions 730 $166.81 $121,771.30 Remodels / Lofts $45.78 $0.00 Apartments & Multi-family $124.35 $0.00 Garages/Sunrooms (STORAGE) 231 $36.40 $8,408.40 Patio/Porch $12.13 $0.00 Enclosed Patio $19.71 $0.00 Decks/Balconies/Stairs 325 $19.71 $6,405.75 Retaining Walls, concrete,masonry $24.26 $0.00 Pools/Spas-Gunite $51.56 $0.00 TI/Stores, Offices $45.78 $0.00 TI/Medical, restaurant, H occupancies $63.70 $0.00 Photovoltaic Systems/ # of panels $400.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Fire Sprinkler System $3.94 $0.00 Air Conditioning - commercial $6.37 $0.00 Air Conditioning - residential . $5.31 $0.00 Fireplace/ concrete, masonry $4,883.11 $0.00 Fireplace/ prefabricated Metal $3,319.61 $0.00 $0.00 $0.00 TOTAL Sl3b,5S5.45 Valuation: Comm/Res (CIR): Building Fee Plan Check Fee Strong Motion Fee Green Bldg. Stand. Fee Green Bldg PC Fee License Tax/PFF License Tax/PFF (in CFD) CFD 1st hour of Plan checkFire Expedite Plumbing Mechanical Electrical $136,585 C $757.41 $530.19 $29.00 $4.00 $163.00 $4,780.49 $2,485.86 TBD TBD TBD CFD Ed Yes (PFF=1.82%) No (PFF = 3.5%) Land Use: Density: Improve. Area: Fiscal Year: Annex. Year: Factor: CREDITS PFF and/or CFD Explanation: c of ity Carlsb ad Print Date: 07/26/2019 Job Address: 1755 Valley P1 Permit Type: BLDG-Permit Revision Work Class: Parcel No: 2050803300 Lot U: Valuation: $0.00 Reference U: Occupancy Group: Construction Type: U Dwelling Units: Bathrooms: Bedrooms: Orig. Plan Check U: Plan Check U: Project Title: Description: KAMINSKI: STRUCTURAL & FOOTING CHANGES Permit No: PREV2017-0110 Residential Permit Revision Status: Closed - Finaled Applied: 06/07/2017 Issued: 07/13/2017 Permit 07/13/2017 Finaled: Inspector: JWest CB162221 Final Inspection: Applicant: Owner: STEVE LUTZKE CASEY P KAMINSKI 1755 Valley P1 CARLSBAD, CA 92008 760-468-3333 FEE AMOUNT MANUAL BUILDING PERMIT FEE $125.00 Total Fees: $125.00 Total Payments To Date: $125.00 Balance Due $0.00 Building Division 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov (City of PLAN CHECK REVISION Development Services Building Division Carlsbad B-15 APPLICATION 1635 Faraday Avenue 760-602-2719 www.carisbadca.gov Plan Check Revision No. t92O17 0110 Original Plan Check No. I (e 2.Z2./ Project Address 1755 Vct ?L4. Date 117-1 Contact 2°y KCt\ cI Ph r1c, 5gc9 215 I Fax NA Email V\P s'r3 1C C CCL (rel Contact Address J7S5 'L. City Zip 92.00 General Scope of Work rkt~V~C' v ^ ts Ce44'\ Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. I., Elements revised: Plans 0 Calculations Soils Energy Other 2. Describe revisions in detail 3. List page(s) where each revision is shown 4. List revised sheets that replace existing sheets C kcir b &r c epou i4cr 5. 615 ICC4 r\ U -c%-\.G(, 10 ewk'scot.3) £Vt&e(à Does this revision, in any way, alter the exterior of the project? fl Yes No Does this revision add ANY new floor area(s)? Yes No Does this revision affect any fire related issues? Yes J No Is this a complete set? Yes E No £Sig nature_ 2 1635 Faraday Avenue, Carlsbad, CA 92008 Ph. 76602 2719 Fax: wwcarlsbadca.gov Email: building@carlsbadca.gov EsGil Corporation In Partnership wit/i government for Building Safety DATE: June 16, 2017 JURISDICTION: Carlsbad) PLAN CHECK NO.: PREV2017-0110 (16-2221 Rev) PROJECT ADDRESS: 1755 Valley PL O APPLICANT J7'JURIS. 0 PLAN REVIEWER 0 FILE SET:I PROJECT NAME: Addition & Remodel for Kaminski Residence The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. El The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. F-1 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LI The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. F-1 EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted:0 00 Telephone #: Date contacted: (b . ) Email: Mail Telephone Fax In Person REMARKS: Revision includes structural change (expand bigger distance for beam and enlarge pad footing. By: Abe Doliente Enclosures: Original set of approved plans (CBI 6-2221) EsGil Corporation 0 GA El EJ 0 MB El PC 6/12/17 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad PREV2017-0110 (16-2221 Rev) June 16, 2017 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: PREV2017-0110 (16-2221 Rev) PREPARED BY: Abe Doliente DATE: June 16, 2017 BUILDING ADDRESS: 1755 Valley PL BUILDING OCCUPANCY: R3/U BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code Icb IBY Ordinance Bldg. Permit Fee by Ordinance ! I Plan Check Fee by Ordinance vi I s125.001 Type of Review: Complete Review E Structural Only El Repetitive Fee Other lvi Repeats • • EE;i Hourly 11Hr. @ * EsGil Fee $ioo.00l I $loo.00l Based on hourly rate Comments: Sheet I of I macvalue.doc +