Loading...
HomeMy WebLinkAbout5940 DARWIN CT; ; FPC2020-0170; Permit4Lr7yit of PERMIT REPORT Carlsbad Print Date: 06/10/2021 Permit No: FPC2020-0170 Job Address: 5940 DARWIN CT, CARLSBAD, CA 92008-7395 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121201700 Track #: Applied: 09/28/2020 Valuation: $813,227.35 Lot #: Issued: 11/09/2020 Occupancy Group: Project #: Finaled Close Out: 06/10/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check#: Final Inspection: Project Title: Description: PRATT & WHITNEY PHASE 2 -NEW NOTIFICATION & ELEVATOR RECALL (63 DEVICES) Applicant: FPContractor: ADT COMMERCIAL A D T COMMERCIAL LLC GREGORY COX P0 BOX 310702 920 SAN DREASEN DR, # STE 102 BOCA RATON, FL 33431-0000 ESCONDIDO, CA 92029-1936 (561) 989-7919 (619) 719-2633 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FIRE ALARM SYSTEM SUBMITTAL For PRATT&WHITNEY PHASE 2 5940 DARWIN COURT CASRLBAD, CA. 92008 Submitted By: ADT COMMERCIAL 920 South Andreasen Drive, Suite 102, Escondido, California 92029 (760) 233-9787 LIFE SAFETY & INCIDENT MANAGEMENT Intelligent Fire Alarm Systems iO64,O1OOO' EDWARDS' Catalog t> Small Building Fire alarm Solutions FDNY COA 6227 0 7165-1657: 0244 53000 Overview EDWARDS brand intelligent life safety systems offer the power of high-end intelligent processing in configurations that deliver uncomplicated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet connectivity, and a full line of easily- configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The i064 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The iO1 000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. The iO1 000 panel includes four NACs that may be wired for either Class A or Class B operation. The RZ116-2 module adds even more capacity to iO installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them an ideal retrofit solution that can accommodate new intelligent detectors, as well as existing conventional devices. iO Series supports a wide range of high-end features, including: Supports 10-Year Carbon Monoxide detectors R-Series remote annunciators SIGA-REL Releasing Modules Fully integrated CO detection using Signature Series detectors with or without audible signaling Features Auto-programming reduces installation time Supports Signature Series intelligent modules and detectors Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Alarm ON command manually activates alarm condition S Page 1 of DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.5 D7 ]'0 0 0 08 0 4D9.1 Application EDWARDS iO Series life safety systems are powerful intelligent .solutions for small to mid-sized buildings. Advanced intelligent technology delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Signature Series electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Mean- while, innovative programming allows the designer to customize the system to precisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Addressable Technology boosts the reliability of EDWARDS fire alarm systems. When combined with iO Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All EDWARDS systems are built to exacting reliability benchmarks. Clear-cut remote annunciation Remote annunciation is a strong suit of the iO Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as common control capabilities. iO control panels also supports graphic annunciation with optional RA Graphic Annunciator nterface modules. Each interface provides common control and 32 LEDs. *Flexibility built right in Two fully-programmable front panel switch/LED combinations provide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Programming and remote diagnostics EDWARDS iO Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, iO Series systems interface to a PC running com- patible iO-CU software. This option offers full system configuration in the familiar Windows operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of iO Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to download to the panel from the iO-CU, or upload and view system reports using the iO-CU. is Available system reports include: Correlation groups, Device details, Device maintenance, History, Internal status, System configuration, System status, Walk test, Dialer, and CO runtime. Page 2 of 8 Perfect for retrofits EDWARDS iO Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to iO technology without the expense or disruption of rewiring the entire building. iO control panels also support the ingenious RZ11 6-2 Zone Module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intelligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Scalable IP and Cellular Communications Several popular third-party IP/Cellular communicators have been tested with the iO control panels and are compatibility listed to UL864. The IP/Cellular communicators meet NFPA72 2013 edition requirements for sole or secondary transmission paths. Using IP/ Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please see the iO control panel compat- ibility documentation part number 3102353-EN for a full list of compatible communicators. Signals with a difference iO system NACs are configurable to fully support the advanced signaling technology of EDWARDS Genesis and Enhanced Integ- rity notification appliances. These devices offer precision synchro- nization of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. A complete line of accessories iO Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions Surface Mounting Holes (3) Backbox with Door Attached Semi-flush mounting Holes (4) Backbox with door and trim kit attached. Panel dimensions, in (cm) Model 01 I D2 D3 I 04 I 05 I 06 I D7 I 08 I D9 28.0 I 3.85 I 9.0 I 22.0 15.75 I 10.25 I 4.4 I 28.2 I 2.7 01000 (71.1) I (9.8) (22.8) I (55.8) I (40.0) (26.0) (11.1) I (71.6) I (6.8) 21.5 3.85 I7.5 I 15.5 I 14.25 10.25 I .s 21.7 I 2.7 064 (54.6) (9.8) I (19.0) (39.4) (36.2) (26.0) 111.41 (55.1) (6.8) Add 1-1/2 in. (3.81 cm) to D1 and 05 dimensions for trim kit.The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.5 System Layout i01000 Any combination of two single- or dual Signature loop modules Standard Loop: 250 points (one expansion slot) 10-SDC2 Expander, Loop 1 k2:250 points (one expansion slot) 110-SDC1Expander Loop: 250 points (one expansion slot) ,U00 feet of wiring per loop--------------------------------------------------------------- --- - lb 13 ou 13 Four la ss B or two optional Class A NACs Optional 10 A or 6.5 A Booster Ethernet (SA-ETH) 0—i I 7—r—i i0-SDC2 Expander, Loop 2 of 2:250 points ---------------------------------------------------- f W!1111111 TM W11111111 U Four Class B or two optional Class A NACs DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A Each i01000 panel has room for up to two Signature loop control- ler modules in any combination of single or dual 250-device loops. i01000 loops support 125 detectors and 125 modules. i064 Loop supports up to 64 intelligent devices of any type. Up to 20,000 feet of wiring. 911011111111 Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster Power Supply ---_r Up to eight remote annunciators Ethernet (SA-ETH) DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A Each i064 panel ships with one Signature loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. Up to eight remote annunciators Sixteen Conventional lDCs, two additional NACs with RZ116-2 module 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (J 1) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries Page 3 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.5 Cbss Bwirirg Auxiliary & smoke power outputs (T133) The control panel provides two auxiliary power T. outputs that can be used for powering ancillary 0 L.. equipment such as remote annunciators and two (1) wire smoke detectors. Aux 2 can be software - selected to operate continuously. The circuit is 0 supervised for shorts and grounds. 0 -_ (2) — Circuit specifications 0 :- Circuit voltage 21.9 to 28.3 V range NZ Resettable circuit 24VDC nominal at 500 mA (3) (Aux power 2) Continuous circuit 24VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering 0 two-wire smoke detectors. — (4) 0 Note: Any current above 0.5 amp connected to both Aux — 1 and 2 will reduce the total available NAC power by that amount. — (1) Trouble Alarm, trouble, and supervisory relay (TB3) (2) Supervisory The trouble relay is normally-open, held closed, (3) Alarm and opens on any trouble event or when the panel is de-energized. The supervisory relay is (4) Smoke/Aux normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Alarm I Trouble Supervisory Type Form C Form A Voltage 24VDC at 1 A resistive 24VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. NO NC NO NC NO Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style Y) or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet nce Class B chammeo I cianmm 2 Class A CIRMI D2 +— +— Wiring & Configuration Signature device loop he system provides one Signature device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit specifications 101000 i064 Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Communication Maximum 20V peak-to-peak line voltage Circuit current 0.5 A max Circuit 660 total, 0.5 jF, max impedance Isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using a SIGA-CC1 S or SIGA-MCC1 S module and Genesis or Enhanced Integrity notification ap- pliances. CbSS 8 wiring CGnAwiring Wag aid d.na. 06v106 Loop OaeLiI1 deid deJid Notification appliance circuits (TB2) 101000 control panels come equipped with four notification ap- pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications i01000 i064 CircuitType 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLA module Voltage 24VFWR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 6OHz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 50 Hz. Impedance 260 total, 0.35 pF max EOLR 15K0,1/2W Synchronization Supported system-wide cim Awining OUR OUR • Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. Page 4of8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 1.5 Option Cards EDWARDS i0 Series panels are supported by a complete line of modules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet provides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The iO-SDC1 is a single loop controller card that can be used with the i064 as a replacement for the standard 64-point loop, or with the iO1 000 as a 250-point expansion module. The i0-SDC2 is a 500-point dual loop controller card for the i01000 that provides two SLC circuits, each with 125 detector addresses and 125 module addresses. Specifications iO-SDC1 iO-SDC2 Device Addresses iOl 000: one loop, 250 device addresses i064: 64 addresses i01 000: two loops, 500 device addresses Wiring Class B or Class A Operating Voltage 24 VDC Operating Current (fully loaded loop) Standby: 55 mA Alarm: 80 mA Standby: 45 mA Alarm: 70 mA Note: These ratings do not include the use of two-wire smoke modules. Communication Line Max. 20.6 V peak-to-peak Voltage Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm') Circuit Current 0.5 A max. Max total loop 660 resistance Max total loop 0.5 pF capacitance Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault 0to5kfl Impedance Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interface Card The SA-ETH card provides a standard 10/100 Base T Ethernet network connection for connecting to an intranet, a local network, or the Internet. The card can be used to download configuration programming from the 10-CU to the panel. The Ethernet card is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-ETH specifications Ethernet 10/100 Base Operating environment Temperature 32t0 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Page 5 of 8 RZI16-2 Remote Zone Interface Module The RZI16-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. It requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZI16-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-segment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZI16-2 Specifications Current Standby current for 4.7 k EOL (U.S.) 4.8 mA! circuit Standby current for 3.9 k EOL (Canada) 5.7 mA! circuit Alarm current at nominal voltage 31.1 mA/circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 250 per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kO (U.S.); 3.9<0 Canada Zone voltage 22.78 Vfor 4.7 ko(U.S.) 22.08Vfor 3.9 ko (Canada) Alarm current 31.1 mA/ channel at nominal voltage Alarm impedance range < 680 0 Trouble impedance range > 5.55 kO Supervised output circuits EOL resistor 15 kO Quantity 2 Short circuit detection <2.6<0 Open circuit detection >61.9 kfl Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), iOl000, APS DATA SHEET [85001-0135 Not to be used for installation purposes. Issue 1.5 11 Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24VDC SA-DACT wiring Towxil p#c1eiad Phone awes The dialer phone lines connect to connectors on the dialer's main circuit board. Phone line 1 connects to connector J4 and phone line 2 connects to connector A. SA-DACT Dialer The SA-DACT provides communications between the control • panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the iO-CU. The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SSA-DACT specifications Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (C31/38X) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRS Receiver Models Formats Ademco 685 Contact ID FBll CP220 Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch D6600 Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact ID SA-232 RS-232 interface The SA-232 card provides an RS-232 interface with iO panels. It can be used for connecting a printer to the control panel to print system events. The card also can be used for connecting a computer to download a configuration program from the iO-CU to the control panel. The RS-232 card is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard ElA-232 Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (i064 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with i064 control panels only. 101000 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VFWR Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 toll AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) D16L-iO LED Display Expander (101 000 only) The D1 6L-i0 LED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone. Two D16L-i0 LED display expanders can be installed in each i01000 panel. (3) ,,, (4) LED 1 LED 2 LED Expander 1 LED Expander 2 Alarm/non-alarm and trouble zone LEDs Page 6 of 8 DATA SHEET [85001-0135 Not to be used for installation purposes. Issue 1.5 Specifications i064 i011000 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (125 modules) detectors and 125 modules max.). Addresses 1 t 125 are for detectors and addresses 126 to 250 are for modules Maximum T-taps: 63 (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B (Style Y), Class A (Style Z) optional 4 Class B (Style Y) or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1:500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) circuit Aux power 2:500 mA, 24 VDC Output: 28.3 to 21.9 VDC, special application Note: For a list of compatible devices, see the 1064 and iOl 000 Series Compatibility List (P/N 3102353-EN) Loop circuit Maximum loop resistance: 660 Maximum loop capacitance: 0.5 iF Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA Alarm: 125 mA/l 15 mA (not including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the i064 control panel cabinet and two 18 Ah batteries will fit in the iO1000 control panel cabinet. If larger batteries are required, use an EDWARDS battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38X) Communication formats: Contact ID (SIA DC-OS) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance OtoSkO Alarm contact Form C N.O. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.O. 24 VDC at 1 A (resistive load) Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm) Page 7 of 8 DATA SHEET [85001-0135 Not to be used for installation purposes. issue 1.5 C S Ordering Information Part Description i01000 Fire Alarm Systems 101 000G Four loop system with one 250-point loop installed. 110v, gray door. LIFE SAFETY & INCIDENT MANAGEMENT I01000G-2 Four loop system with one 250-point loop installed. 230v, gray door. Contact us 101000G-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. Phone: 800-655-4497 (Option 4) I01000G-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. Email: edwards firer&carrier.com I01000G-CA Four loop system, one 250-point loop installed. 110v, gray door, LED strips, Canada. Website: edwardsfiresafety.com I01000GD Four loop system, one 250-point loop installed. 110v, gray door, with dialer. I01000G-F Four loop system, one 250-point loop. llov, gray door, LED strips, French Canada. 8985 Town Center Pkwy IO1000G-PG Four loop system with one 250-point loop installed. llov, gray door, Portuguese. Bradenton, FL 34202 IO1000G-SP Four loop system with one 250-point loop installed. llov, gray door, Spanish. 2020 Carrier 10100013 Four loop system with one 250-point loop installed. 110v, red door. All rights reserved. IO1000R-2 Four loop system with one 250-point loop installed. 230v, red door. I01000RD Four loop system, one 250-point loop installed. llov, red door, with dialer. SA-TR1M2 iO1000 Flush mount trim, black. i064 Fire Alarm Systems 1064G One loop system with one 64-point loop installed. 110v, gray door. 1064G-2 One loop system with one 64-point loop installed. 230v, gray door. 1064G-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. I064G-2-SP One loop system with one 64-point loop installed. 230v, gray door, Spanish. 1064GD' One loop system, one 64-point loop installed. 110v, gray door, with dialer. 1064GL One loop system, one 64-point loop installed. 110v, gray door, English Canada. I064GL-F One loop system, one 64-point loop installed. ilov, gray door, French Canada. 1064G-PG One loop system with one 64-point loop installed. ii 0v, gray door, Portuguese. I064G-SP One loop system with one 64-point loop installed. ii 0v, gray door, Spanish. I064R One loop system with one 64-point loop installed. liov, red door. I06413-2 One loop system with one 64-point loop installed. 230v, red door. I064RD One loop system, one 64-point loop installed. 110v, red door, with dialer. SA-TRIMi i064 Flush mount trim, black RZI 16-2 Remote Zone Interface Module. 16 Class B IDCs, 2 Class B Output. Includes bracket. SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers & computers, mounts in cabinet. SA-ETH Ethernet Port, Slave, mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. iO64 systems only. D16L-iO-2 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. For iOi 000 only. D16L-iO-1 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16. For iOi 000 only. D8RY-iO-2 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iO1000 only. D8RY-i0-1 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For iOl 000 only. Accessories CTM CityTie Module. 2-gang. Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8" x 14' x 3.5"- red. SIGA-REL Releasing Module PT-iS System Printer BC-1 Battery Cabinet. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. BC-1 R Battery Cabinet - Red. 14.0" x 18.25" x 7.25' Holds two 12V24A batteries. BC-1 EQ Seismic hardening Kit for iO series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools b-CU 260097 10 Series configuration and diagnostics utility. R5232 cable, 4 conductor, DB9 PC interface Page 8of8 DATA SHEET E850010135 Not to be used for installation purposes. Issue 1.5 S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1657:0244' Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Single and multi-loop analog addressable fire alarm control unit. Local, local with shunt, auxiliary, remote station, central station, releasing device. Power limited, non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterflow and sprinkler supervisory service. Models "EST"iO1OOÔG,'iO1000G-2, iOI000GD, i01000R, iO1000R-2, i01000RD, i064G, i064-GD, i064-R, i064-RD, i064G-2, i064R-2; i0500G, iOSOOGD, i0500R, iOSOORD, i0500G-2, i0500R-2. Models "Vigilant/Kidde" VS1-G, VS1-GD, VS1-R, VS1-RD, VS1-G-2, VS1-R-2; V52-G, VS2-GD, V52-R, V52-RD, V52-G-2, VS2-R-2, v54-G, vs4-G-2, vs4-GD, vs4-R, vs4_r-2, vs4-RD,. Models "FireworX/Kidde" FX-64G, FX-64GD, FX-64R, FX-64RD, FX64G-2, FX-64R-2, FX-254G, FX-254GD, FX-254R, FX-254RD, FX254G-2, FX-254R-2, FX-1000, FX1000D. Models "Edwards Signaling" E-FSA64G, E-FSA64GD, E-FSA64R, E-FSA64RD, E-FSA250G, E-FSA250GD, E-FSA250R, E-FSA250RD System Components: SA-DACT; Dialer SA-CLA; Class A Adapter SA-ETH; Ethernet Adapter SA-232; R5232 Module D16L-iO, -VS, -Fa, D8RY-iO-1, D8RY-iO-2, D8RY-VS, 16 Zone Front Panel LED XAL250, V-SLC, XAL127; SLC Loop Driver io-SDCI, V-SLC2-1, FX-SLCI Single SLC Card, 250pt io-SDC2, V-SLC2-2, FX-SLC2 Dual SLC Card, *500pt *pT1.S: System Printer *pT1p: System Printer Parallel Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. *102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires August 29, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1657:0244 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. *These control units meet the requirement of UL 864, 9th Edition Standard. S *102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2019 Listing Expires August 29, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division EDWARDS Catalog I> Strobes, Horns, Bets, Chimes EID:WARLJ=- LIFE SAFETY INCIDENT MANAGEMENT F:iRE Field Configurable Ceiling Strobes — Genesis Series - _ MEA 7125-1657: 0219 S5389 Overview Genesis life safety and mass notification/emergency communica- tions (ECS/MNS) ceiling strobes are small, compact, and attractive visible emergency signaling devices. Protruding no more than 1.6" (41 mm) from the ceiling, Genesis strobes blend with any decor. Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses. Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FuliLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FuliLight technology go well beyond the minimum UL-required "cross" pattern, significantly exceeding UL-1971 and ULC-S526 light distribution requirements. Depending on the model, clear lens Genesis ceiling strobes fea- ture 15 to 95, or 95 to 177 candela output (see ordering informa- tion), which is selectable with a conveniently-located switch. The candela output setting remains clearly visible even after final instal- lation, yet it is locked in place to prevent unauthorized movement after installation. Genesis ECS/MNS appliances offer emergency signaling with clear amber or blue lenses. They are ideal for applications that re- quire differentiation between life safety and mass notification alerts. Standard Features Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd clear strobe lens models available - Switch settings remain visible even after the unit is installed ECS/MNS models available - Amber and blue lens models available. See Ordering Information for details. Unique low-profile design - 30 per cent slimmer profile than comparable signals - Attractive appearance - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - #18 to #12 AWG terminals - idea] for long runs or existing wiring Unparalleled performance - Exclusive FuliLight strobe technology produces the industry's most even light distribution - Precision timing electronics meet tough synchronizing standards for strobes - Low current draw minimizes system overhead Approved for public and private mode applications - UL 1971-listed as signaling devices for the hearing impaired - UL 1638-listed as protective visual signaling appliances - UL/ULC listed for ceiling or wall use S S Page 1 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 2.1 Application Genesis strobes are UL 1971 or 1638 listed for indoor use. Prevailing Scodes require strobes to be used where ambient noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. Synchronization for multiple strobe lights in a single field of view is required. ECS/MNS Applications Genesis ECS/MNS appliances bring the same high-performance life safety features and unobtrusive design to mass notification applica- tions. Available as standard units with clear, amber or blue lenses with optional ALERT markings, they are ideal for applications that require differentiation between life safety and ECS/MNS signals. Units are also available (special order) with red or green lenses. Installation All models are intended for indoor applications only. Strobes mount to any flush North-American 4" square electrical box, 21/" (54 mm) deep. Genesis ceiling strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiling. Once installed with the cover in place, no mounting screws are visible. S IN 10 Dimensions 6.8" dia. (173 mm) (25 mm) Light output (effective cd) Percent of UL rating versus angle - Percentage of rated output '- Angle—"' Horizontal and vertical outputs reflect the same pattern. Field Configuration Depending on the model, Genesis ceiling speaker-strobes have multi-candela output Candela switch (see ordering information). The output / setting is changed by simply opening the device and sliding the switch to the desired setting. The strobe does not have to be removed to change the output setting. 7 The setting remains visible through a small Indicator window on the front of the device after the cover is closed. 90 Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 WARNING: These de\tices will not operate without electrical power. As fires frequently to 2.5 mm2) wiring. Strobes are interconnected with a single pair of cause power interruptions, we suggest you discuss further safeguards with your local fire protection specialist. wires as shown below. To listed To next I control end-of-line or return to panel I fire alarm c!! J t appliance, __ WI control equipment Page 2 of DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 2.1 S Current Draw Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or 0 designations. Standard output models (mA) High Output models (mA) UL or "D" or or "B" or "A" or "D" "1 5I or 'C'111501, or "B" or "A" Rating RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 109 151 281 318 330 392 502 565 16Vfwr 131 194 379 437 432 518 643 693 Standard output models (mA) High output models (mA) Typical "15" or "D" 1130" or "C,, 1175" or "B" 1195" or "A" "95" or "D" "115" or "C" "150" or "B" 11177" or "A" Current RMS RMS RMS RMS RMS RMS RMS RMS 16 Vdc 94 140 273 325 333 392 499 551 20 Vdc 74 108 205 244 259 303 378 429 24 Vdc 63 90 168 194 212 245 306 342 33 Vdc 48 70 124 139 155 180 211 236 16Vfwr 126 187 368 403 484 570 673 724 20Vfwr 108 156 281 333 380 438 537 604 24Vfwr 97 139 240 270 318 361 434 484 33Vfwr 89 119 197 214 245 269 308 338 Light Output Standard output models High output models Switch Settings (candela) Switch Settings (candela) Lens Listings Lens Listings . color Standard Setting Setting Setting Setting color Standard Setting Setting Setting Setting Clear UL 1971 95 cd 75 cd 30 cd 15 cd Clear UL 1971 177 cd 150 cd 115 cd 95 cd Amber UL 1638 82 cd 65 cd 26cd 13 cd Amber UL 1638 155 cd 130 cd 100 cd 82 cd Blue UL 1638 40 cd 31 cd 12 cd 6 cd Blue UL 1638 80 cd 78 cd 59 cd 48 cd Specifications Housing Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Red and white models available. Lens Optical grade polycarbonate (clear). Mounting Flush mount to North American 4-inch square electrical box, 2-1/8 (54 mm) inches deep. No extension ring required. Suitable for indoor wall or ceiling applications. Wire Connections Screw terminals: #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size. Operating Voltage Regulated 16 to 33 Vdc, 16 to 33 Vfwr. Operating Indoor: 32-120° F (0-49° C) ambient temperature; 0-93% relative humidity. environment Agency listings/ g Meets or exceeds year 2004 UL requirements for standards UL1 638 and UL1 971 and Canadian requirements for standards approvals CAN/ULC S526-02 and CAN/ULC S524-01. All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. Strobe output rating Clear: UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC-VM) and 95/115/150/177 cd (GC-VMH) Amber: CAN/CSA-C22.2 No. 205, CAN/ULC-5526, UL 1638: selectable 13/26/65/82 cd (GCW*VMA), 82/100/130/155 cd (GCW*VMHA) Blue: CAN/CSA-C22.2 No. 205, CAN/ULC-5526, UL 1638: selectable 6/12/31/40 cd (GCW*VMB), 48/59/78/80 cd (GCW*VMHB) Strobe operating GC-VM series strobes: non-coded, filtered 16-33 Vdc voltage or unfiltered 16-33 Vdc FWR. Strobe flash rate GC-VM series strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely within 10 milliseconds. Temporal setting (private mode only): synchronized to temporal output of Genesis audible signals on same circuit. Synchronization Meets or exceeds UL 1971 requirements. Maximum allowed resistance between any two devices is 20 Ohms. Refer to . specifications for the synchronization control module, this strobe, and the control panel to determine allowed wire resistance. Synchronization SlGA-CC1S, SIGA-MCC1S, SIGA-CC2A, SlGA-MCC2A, G1M-RM Sources BPS6A, BPS1 OA, APS6A, APS1 OA, iO Series, Fireshield Plus 3, 5 and 10 zone. Add Gi M for G1 -CVM &G1 -HDVM devices only. Page 3 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. issue 2.1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.fire@carrier.com Website: edwardstiresafety.com 8985 Town Center Pkwy Bradenton, FL 34202 © 2020 Carrier All rights reserved. Ordering Information Light output switch settings for UL 1971 listed models are selectable by numeric candela value. ECS/MNS appliances are selectable by A, B, C, or D designations. Model I Housing I Marking I Lens I Strobe I Ship Wt. Life safety Aoøliances (c/w runnina man icon screen arinted on housina GC-VM White None Clear Selectable 15, 30, 75, 0r95 cd 1.8 lb. (0.82 kg.) GCF-VM White "FIRE" GCFR-VM Red "FIRE" GC-VMH White None Selectable high output 95,115,150, or177cd GCF-VMH White "FIRE" ECS/MNS Aooliances (no runnina man icon on housinci GCWA-VMA White "Alert" Amber Selectable A, B, C, D 1.8 lb. (0.82 kg.) GCWA-VMC Clear GCWN-VMA None ______ Amber GCWN-VMB Blue GCWN-VMC Clear GCWA-VMHA "Alert" Amber Selectable high output GCWA-VMHC Clear GCWN-VMHA None Amber A, B,CorD Clear GCWN-VMBH I lue GCWN-VMHC S Page 4 of 4 DATA SHEET E85001-0557 Not to be used for installation purposes. Issue 2.1 0 C;) 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. i7125-1657:02 19 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models GC-VM,GCF-VV, GCFR-VM, GC-VMH, GCF-VMH, GCWAVMC*, GCWNVMC*, GCWAVMHC* and GCWNVMHC* multiple candela synchronizable strobe lights. The lights are only considered synchronized when used in conjunction with listed Model G1M-RM (CSFM Listing No. 7300-1657:201) sync module, which may employ Model SIGA-CC1S (CSFM Listing No. 7300-1657:121) Auto Sync Output Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VdcNfwr GC candela: 15cd, 30cd, 75cd, or 95od H candela: 950d, 115cd, 150cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only, mounted on a wall or a ceiling. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7125-1591:219 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2020 Listing Expires CJune 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Genesis ceiling horn-strobes are small, compact, and attractive audible-visible emergency signaling devices. Protruding no more than 1.6" (41 mm), Genesis horn-strobes blend with any decor. S EDWARDS' Cata!ocj 1> Strobes, Horns, Bells, Chimes LIFE SAFETY INCIDENT MANAGEMENT Field Configurable —One or more patents pending. Ceiling Horn Genesis Series T FCC MEA (E 7300-1657: 0202 S218 Overview Standard Features Thanks to patented breakthrough technology, EDWARDS Gen- esis strobes do not require bulky specular reflectors and lenses Instead, an exclusive cavity design conditions light to produce a highly controlled distribution pattern. Significant development efforts employing this new technology have given rise to a new benchmark in strobe performance - FullLight technology. FullLight strobe technology produces a smooth light distribution pattern without the spikes and voids characteristic of specular reflectors. This ensures the entire coverage area receives consis- tent illumination from the strobe flash. As a result, Genesis strobes with FullLight technology go well beyond the minimum UL-required "cross" pattern. Depending on the model, Genesis horn-strobes feature 15 to 95, or 95 to 177 candela output (see ordering information), which is selectable with a conveniently-located switch on the front of the device. The candela output setting is clearly visible even after final installation, yet it remains locked in place to prevent unauthorized movement after installation. Genesis hom-strobes feature textured housings in architecturally neu- tral white or eye-catching fire alarm red. An ingenious iconographic symbol indicates the purpose of the device. This universal symbol is code-compliant and is easily recognized by all building occu- pants regardless of what language they speak. Models with "FIRE" markings are also available. Field configurable - no need to remove the device! - 15/30/75/95 cd and 95/115/150/177 cd models available - Switch settings remain visible even after the unit is installed - Low/high dB settings Unique low-profile design - 30 per cent slimmer profile than comparable signals - No visible mounting screws - Available with white or red housings Easy to install - Fits all standard 4" square electrical boxes with plenty of room behind the signal for extra wire - no extension ring or trim plate needed - Pre-assembled with captive hardware - no loose pieces - #18 to #12 AWG terminals - idea] for long runs or existing wir- ing Unparalleled performance - Exclusive FullLight strobe technology produces the industry's most even light distribution - Single high-efficiency microprocessor controls both horn and strobe - Low current draw minimizes system overhead - Independent horn control provided over a single pair of wires - Highly regulated in-rush current allows the maximum number of strobes on a circuit - 100 dB peak - multiple frequency tone improves wall penetration S Page 1 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1.1 Application Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed 105 dBA (87dBA in Canada), where occupants use hearing protection, and in areas of public accom- modation as defined in the Americans with Disabilities Act (see application notes - USA). Combination horn-strobe signals must be installed in accordance with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling- or wall-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels, where occupants use hearing protection, and in areas of public accommodation. Consult with your Authority Having Jurisdiction for details. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds other over a two-hour period) when used with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. NOTE: The flash intensity of some visible signals may not be adequate to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90% of sleeping persons is approximately 100 cd. EDWARDS recommends that strobes in sleeping rooms be rated at at least 110 cd. WARNING: These devices will not operate without electrical power. As fires frequently cause power interruptions, further safeguards such as backup power supplies may be required. Horns Genesis horn output reaches as high as 99 dB (peak) and features a unique multiple frequency tone that results in excel- lent wall penetration and an unmistakable warning of danger. All models may be configured for either coded or non-coded signal circuits. They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. The suggested sound pressure level for each signatng zone used with alert or alarm signals is at least 15 dB above the average ambient sound level, or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater, measured 5 feet (1.5 m) above the floor. The average ambient sound level is, A-weighted sound pressure measured over a 24-hour period. Installation and Mounting All models are intended for indoor wall or ceiling applications only. Horn-strobes mount to any flush North-American 4" square electrical box. I Genesis ceiling horn-strobes simply unlatch and twist to open. This gains access to mounting screws and the selectable candela switch. The shallow depth of Genesis devices leaves ample room behind the signal for extra wiring. Once installed with the cover in place, no mounting screws are visible. EDWARDS recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of national and local fire alarm codes. Field Configuration Depending on the model, Genesis horn-strobes may be set for 15 to 95, or 95 to 177 candela output (see ordering information). The output setting is changed by simply opening the device and sliding the switch to the desired setting. The horn-strobe does not have to be removed to change the output setting. The setting remains visible through a small window on the front of the device after the cover is closed. The horn-strobe comes factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Wiring Field wiring terminals accommodate #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wiring. Horn/strobes are interconnected with a single pair of wires as shown below. 0 Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Dimensions 6.8' dia. p (173 mm) / 1.0" (25 mm) / Polarity shown in alarm condition To next appliance, end-of-line or return to control equipment 101 Note: Strobes must have continuous voltage. Page 2of4 DATA SHEET E850010559 Not to be used for installation purposes. Issue 1.1 Light output - (effective cd) Percent of UL rating versus angle Peroenthgo of rated output - .5. Current Draw GC-HDVM Temporal Horn-strobe: High dB Setting UL Rating 15 cd RMS 30 cd RMS 75 cd RMS 95 cd RMS 16 Vdc 147 190 316 372 16Vfwr 189 253 417 451 GC-HDVM Temporal Horn-strobe: High dB Setting Typical 15 cd 30 cd 75 cd Current RMS Mean RMS Mean RMS Mean 95 cd RMS Mean 16 Vdc 111 95 152 143 281 276 333 328 20 Vdc 91 80 124 117 219 214 257 251 24 Vdc 80 71 108 101 185 180 212 207 33 Vdc 69 62 89 84 144 140 160 156 16Vfwr 153 81 218 123 388 240 420 268 20Vfwr 141 70 190 100 325 188 378 219 24Vfwr 135 64 176 90 280 154 310 180 33Vfwr 139 61 167 80 241 122 254 133 GC-HDVM Temporal Horn-strobe: Low dB Setting Typical 15 cd 30 cd 75 cd Current RMS Mean RMS Mean RMS Mean 95 cd RMS Mean 16 Vdc 108 91 149 139 275 269 327 322 20 Vdc 87 75 120 113 214 209 250 245 24 Vdc 76 66 103 97 180 175 205 201 33 Vdc 64 57 85 80 138 135 153 150 16Vfwr 141 76 204 118 384 239 418 265 20Vfwr 127 65 176 95 312 181 371 214 24Vfwr 118 60 162 82 262 149 301 171 33Vfwr 127 56 155 73 229 118 249 129 GC-HDVMH High cd Temporal Horn-strobe: High dB Setting 95 cd 115 cd 150 cd 177 cd RMS RMS RMS RMS 341 399 506 570 487 578 670 711 GC-HDVMH High cd Temporal Horn-strobe: High dB Setting 95 cd 115 cd 150 cd 177 cd RMS Mean RMS Mean RMS Mean RMS Mean 324 322 377 374 477 474 554 551 258 256 299 296 369 366 417 414 220 217 252 249 304 301 341 338 172 169 188 185 223 220 244 241 463 265 535 312 665 400 718 442 392 211 439 240 517 287 587 334 346 179 382 212 458 246 498 271 296 142 323 152 358 178 387 194 GC-HDVMH High cd Temporal Horn-strobe: Low dB Setting 95 cd 115 cd 150 cd 177 cd RMS Mean RMS Mean RMS Mean RMS Mean 317 315 378 376 480 477 544 542 252 250 292 290 364 362 414 411 212 211 245 243 297 295 334 332 159 157 181 179 215 213 234 232 461 265 521 305 656 396 705 432 381 208 437 242 508 285 576 326 335 172 370 195 440 235 485 264 285 134 308 149 349 169 373 186 Notes and Comments Current values are shown in mA. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. EDWARDS recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations. Use the Vtwr RMS current ratings for unfiltered power supply calculations. Fuses, circuit breakers and other overcurrent protection devices are typically rated for current in RMS values. Most of these devices operate based upon the heating affect of the current flowing through the device. The RMS current (not the mean current) determines the heating affect and therefore, the trip and hold threshold for those devices. Our industry has used mean' currents over the years. However, UL will direct the industry to use the 2004 RMS values in the future. dBA output UL464 Average Peak High dB Setting Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 79.8 83.2 90.6 93.6 24 Vdc 83.3 85.4 93.6 96.6 33 Vdc 85 87.8 1 95.7 1 98.7 Low dB Setting UL464 Average Peak Temporal Steady Temporal! Steady Temporal! Steady 16 Vdc 75 79.3 86.3 88.7 24 Vdc 78 83 88.8 92.4 33 Vdc 1 80.9 85.9 91.8 1 95.1 Notes 1. All values shown are dBA measured at 10 feet (3.01 m); 2. UL464 values measured in reverberation room; 3. Average and Peak values are measured in anechoic cham- ber. Page 3 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1.1 Specifications Textured UV stabilized, color impregnated engineered plastic. Exceeds 94V- Housing 0 UL flammability rating. Red and white models available. Mounting North-American 4" square box, 2 1/8" (54 mm) deep (indoor wall or ceiling applications only). Wire connections Screw terminals: single input for both horn and strobe. #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size Operating environment Indoor: 32-120°F (0-49°C) ambient temperature. 93% relative humidity Meets or exceeds ULC-S525 & ULC-5526, year 2004 UL Agency listings/approvals requirements for standards UL1 638 and UL1 971, and complies with UL1 480. All horn-strobes comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule. CSFM, MEA, FM. GC-H DVM series temporal-tone horn-strobes: non-coded, filtered Operating voltage 16-33 Vdc or unfiltered 16-33 Vdc F\NR (or coded (audible NAC only) when used with optional Gi M Genesis Signal Master) Strobe output rating UL 1971, UL 1638, ULC S526: selectable 15/30/75/95 cd (GC- HDVM) and 95/115/150/177 cd (GC-HDVMH) GC-HDVM series temporal-tone horn-strobes: one flash per second synchronized with optional Gi M Genesis Signal Master indefinitely Strobe flash rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) Temporal setting (private mode only): synchronized to temporal outout of horns on same circuit LUZ= LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.fire©carrier.com Website: edwardsfiresafety.com 8985 Town Center Pkwy Bradenton, FL 34202 © 2020 Carrier All tights reserved. GC-HDVM series temporal-tone horn-strobes: temporal rate synchronized with optional Gi M Genesis Signal Master indefinitely Horn pulse rate within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit without Gi M Genesis Signal Master) is Temporal audible pattern ½ sec ON, ½ sec OFF, ½ sec ON, ½ sec OFF, ½ sec ON, l½sec OFF, then repeat cycle Ordering Information Catalog Housing Ship Number Color Marking Description Wt. lbs (kg) GC-HDVM White None GCF-HDVM White " FIRE" Genesis Ceiling/Wall Horn-Strobe with selectable 15, 30, 75, or 95 cd output 0.82 GCFR-HDVM Red "FIRE " (1.8) GC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe GCF-HDVMH White "FIRE" with selectable 95,115, 150, or 177 cd output Accessories G1M-RM Genesis Signal Master— Remote Mount (1 0.2-gang) (0.1) SIGA-CC1 0.5S Intelligent Synchronization Output Module (2-gang) (0.23) SIGA-MCC1 S Intelligent Synchronization Output Module (Plug-in UIO) 0.18 (0.08) E White Field Configurable Ceiling Horn-Strobes may be ordered with or without optional 'FIRE' marking. Red Horn-Strobes come with 'FIRE" marking. S 0 Page 4 of 4 DATA SHEET E85001-0559 Not to be used for installation purposes. Issue 1.1 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1657:0202 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models 'EST Gi-HV15, -HV30, -HV60, -HV-75, G1-H0V15, -HOV30, -HOV60, -HOV75, -HOV110, GIF-H0V15, -HOV30, -HOV60, -H0V75, -HOV110, GIRF-H0V15, -HOV30, -HOV60, -H0V75, -HOV110, Gi-HDVM, G1R-HDVM, G1F-HDVM, GIRF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, Gi-HDV1575, G I R-HDV1575, G1F-HDV1575, and G1RF-HDV1575 horn/strobes with or without suffixes -Rand -F. Models with HO as part of the model number are a high audible output version of the standard output model. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 24-30 Vdc 16-33Vdc/Vfwr - Models G1-HDVM, G1R-HDVM, G1F-HDVM, G1RF-HDVM, GC-HDVM, GC-HDVMH, GCF-HDVM, GCFR-HDVM, GCF-HDVMH, G1-HDV1575, G1R-HDV1575, Gi F-HDV1575, Gi RF-HDV1575 Candela: 15cd, 30cd, 60cd, 75cd, 110cd 15-95 multi-cd - Models GC-HDVM, GCF-HDVM, GCFR-HVDM 95-177 multi-cd-Models GC-HDVMH, GCF-HDVMH 15/75cd -Models G1-HDV1 575, G R-HDV1575, G F-H Dvi 575, Gi RE-H Dvi 575 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horns and horn/strobe lights for use with separately listed compatible fire alarm control units. Suitable for use with Audible Signal Appliances (CSFM Listing No. 7135-1657:230). For indoor use and wall mount only. Models GC-HDVM, *GCHDVMH GCFR-HDVM, GCF-HDVM and *GCF-HDVMH for ceiling or wall mount. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Formerly 7125-1591:202 *REV 08-20-13 gt This listing is based upon technical data submitted by the the test results and/or other data but does not make an independent applicant. CSFM Fire Engineering staff has reviewed verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires ,June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division EDWARD&I Catalog t> Intelligent Initiating LIFE SAFETY INCIDENT MANAGEMEN Intelligent Duct Smoke Detector MEA 32421657: 0223 Overview The EDWARDS SuperDuct Signature Series smoke detector is the most advanced and most reliable device in its class. Designed for easy installation and superb reliability, SuperDuct represents the perfect balance of practical design and advanced technology. SuperDuct detectors feature a unique design that speeds instal- lation and simplifies maintenance. Removable dust filters, confor- mally coated circuit boards, and optional water-resistant gaskets keep contaminants away from components, ensuring years of trouble-free service. When cleaning is required, the assemblies come apart easily and snap back together in seconds. Standard Features Less than 2" deep for easy installation and applications where space is tight 0 -20°F to 158°F (-29°C to 70°C) operating range with 100 ft/ mm. to 4,000 ft/min air velocity rating assures reliability under harsh environmental conditions Status LEDs remain visible through clear assembly cover Cover monitor switch for added security Standard sampling tube spacing for easy drop-in migration from other detectors A Signature Series photoelectric sensor is incorporated into • Sampling tube can be installed with or without the cover in the design of each SlGA-SD duct smoke detector. This sensor place and can be rotated in 45-degree increments to ensure inherits the power and benefits of this exceptional line of intelligent proper alignment with duct airflow devices. 15.2 to 19.95 Vdc operation Signature Series sensors gather analog information from their smoke sensing elements and convert it into digital signals. The Magnet-activated test switch sensor measures and analyses these signals and compares the One Form C auxiliary alarm relay for controlling ancillary equip- information to historical readings and time patterns to make an ment (e.g., HVAC controls) alarm decision. Digital filters remove signal patterns that are not No special tools required for easy access to field connections typical of fires, which virtually eliminates unwanted alarms. WARNING: Duct detectors have specific limitations. Duct detectors are not a substitute for an open area smoke detector. Duct detectors are not a substitute for early warning detection or a replacement for a buildings regular fire detection system. Smoke detectors are not designed to detect toxic gases which can build up to hazardous levels in some fires. These devices will not operate without electri- cal power. As fires frequently cause power interruptions, EDWARDS suggests you discuss further safeguards with your local fire protection specialist. Signature Series intelligence Environmental compensation with differential sensing for reli- able, stable, and drift-free sensitivity Wide 0.79% to 2.45% obscuration/ft. smoke sensitivity Identification of dirty or defective detectors S Page lof4 DATA SHEET E850010584 Not to be used for installation purposes. Issue 1.1 8.15 In (70.7 cm) 7.75 In 19.7 Cr,,) 06 rn) L _ -- ------------------------------------------- - 0 0 0 0 ill1 1.90 in (4.83 Ed cnn) 1,38 in 5,40 I,, (3.51 -)(13.72 cm) -. 5.45 In (13,84 Application SuperDuct detectors are ideally suited to duct smoke detection Sapplications where early indication of combustion is required within the confined space of ventilation ductwork. Its primary purpose is to provide early warning of an impending fire and to prevent smoke from circulating throughout the building. It is typically used to detect smoke in the supply side of the HVAC system but can provide supervision of the return side as well. Protected premises ~Remote Alarm relay test output ation I - HDuct smokeF.._.J /'— Return detector air HVAC unit Duct smoke' detector Supply air Alarm relay output Re station SuperDuct detectors continually sample air flow in the HVAC duct and initiate an alarm condition whenever smoke is detected. An alarm is activated when the quantity (percent obscuration) of combustion products in that air sample exceeds the detector's sensitivity setting. Signature Series Intelligence *ike all Signature detectors, the SIGA-SD features electronic addressing and issues a dirty sensor warning when it reaches its preset limit. The dirty sensor warning indicates the sensor is op- erating within its specified limits but is in need of servicing. When the detector's ability to compensate for environmental changes has reached its limit, the duct smoke detector signals a trouble condition. The SIGA-SD also uses differential sensing to prevent gradual environmental changes from triggering unwanted alarms. A rapid change in environmental conditions, such as smoke from a fire, causes the detector to signal an alarm state, but dust and debris accumulated over time does not change alarm sensitivity. Each Signature Series SuperDuct detector contains a microproc- essor that performs comprehensive self-diagnostics and stores the results in nonvolatile memory. Stored results include details such as hours of operation, last maintenance date, and number of alarms and troubles. This information can be retrieved and reviewed when desired. Detector Configuration The detector assembly cover provides easy access to the smoke sensor, its wiring connections, sample and exhaust tubes, and the smoke chamber itself. Air enters the detector's sensing chamber through a sampling tube (ordered separately) that extends into the duct and is directed back into the ventilation system through an exhaust tube (in- cluded). The difference in air pressure between the two tubes pulls the sampled air through the sensing chamber. When a sufficient mount of smoke is detected in the sensing chamber, the detector initiates an alarm. Page 2 of 4 The sampling tube may be installed from either the duct side of the assembly or from inside the sensor compartment, as preferred by the installer. (The exhaust tube must be installed from the duct side.) Sampling tubes may be rotated in 45-degree increments so that air-holes can be aligned to allow the unit to be mounted at virtually any angle relative to the air flow. In installations where the duct smoke detector's controls and indica- tors are hidden from view, a remote test station or an LED indicator can be connected to the detector to provide these functions. Remote Test Stations Labor-saving Remote Test/Reset stations provide r alarm testing from the convenience of a remote Al location. Tests can be performed quickly and safely - without having to climb to the roof. Magnetically- operated and key-operated one-gang models are available. Signature SuperDuct detectors are also compatible with SIGA-LED remote alarm LED. Air velocity in the duct as low as 100 ft/mm. maintains adequate air flow into the sensor smoke chamber through air holes in the air sampling tube and discharges through the exhaust tube. Su- perDuct air sampling tubes must be installed with the inlet holes facing the airstream. Sampling tubes may be rotated in 45-degree increments so that air-holes can be aligned to allow the unit to be mounted in virtually any angle relative to the airflow. SuperDuct sensors are engineered to operate optimally under the harsh environmental conditions frequently found in HVAC duc- twork. Nonetheless, before installing the detector, test the duct air velocity, temperature, and humidity to verify that it is within the operating range of the SuperDuct detector. Consult the SuperDuct installation sheet for details. Dimensions DATA SHEET E85001-0584 Not to be used for installation purposes. Issue 1.1 Exhaust tube gasket Thin Thick gasket Coupling Sampling tube (ordered separately) Plug 0171 an F 11 R lo re Airfi IC #10 sheet metal screw (2X) Wiring Auxiliary equipment I I I [1] No more than one remote test station or LED indicator can be connected to the detector at the same time. Wiring 17 16 15 is unsupervised. Maximum wire resistance is 10 ohms per wire. Assembly High-humidity environments Sampling tube Detector socket Use the SD-PH Protective Housing when installing SuperDuct Exhaust tube detectors in high-humidity environments. The SD-PH is a weather- socket ized housing that prevents condensation on the device by insulat- ing the detectors and providing circulated air from the monitored HVAC duct. The SD-PH also adds a layer of protection against ( physical damage to the unit. Housing Detector air tube conduit holes S The SD-PH is easy to install and service. The hinged and transpar- ent cover provides ready access to the detector, while keeping its status indicators visible at all times. Note: The SD-PH Protective Housing is weatherized against out- door air, but it is not intended for direct outdoor exposure. SIGA-LED (1) Alarm r1° 2 Alarm SD-TRK Test or I 5D-TRM [1] - DO Data In (+) 0 01 Data In(-) 0 0 00 J I L ower indicator Alarm indicator IIIx' IrKKIr.e;4 Data Out (-) Data Out (+) el fl Page 3of4 DATA SHEET E85001-0584 Not to be used for installation purposes. Issue 1.1 Specifications, detector Dimensions 8.70 x 5.45 x 1.90 inches (221 x138x48mm) Wire size 14 to 22 AWG Detection Photoelectric method (light scattering principle) Air velocity 100 to 4000 ft/mm and rating meets the required minimum air pressure differential Air pressure 0.005 to 1.00 inches of differential water Sensitivity 0.79 to 2.46 %/ft obscuration Alarm test 5 seconds response time LED indicators Alarm (red), Power (green) Unsupervised and power- limited Common Quantity: 1 alarm relay Type: Form C Ratings: 2.0 A at 30 Vdc (resistive) Operating 15.2 to 19.95 Vdc voltage Operating Standby: 45 pA Alarm: 45 current pA Inrush: 1 mA Standalone alarm: 18 mA Specifications, test stations Remote Test/Reset Stations provide alarm test, trouble indication, and reset capability from a remote loca- tion. They include a one-gang plate, momentary SPST switch, red ale-rn LED, and terminal block. Magnetically- operated models ([RM) or key-operated models (TRK) are available. Compatible North American 1-gang box electrical Standard 4-in square box, boxes 1-1/2 inches deep, with 1-gang cover LED indicators Alarm (red) LED type Clear lens Wire size 14 to 22 AWG Resistance per 10 Ohms, max. wire requirements See controller specifications LED circuit Voltage: 3 Vdc, max. ratings Current: 30 mA, max. Switch ratings Voltage: 125 Vdc, max. (SD-TRK) Current: 4 A, max. Switch ratings Voltage: 200 Vdc, max. (SD-TRM) Current: 0.5 A, max. Compatible SuperDuct conventional detectors two-wire and Signature duct smoke detectors -4°F to 158°F (-20°C to Operating 70°C) Humidity: 93% RH, environment noncondensing Storage -4 to 140 °F (-20 to 60 °C) temperature Agency listings UL, ULC, MEA, CSFM S bWARDS LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.fire@carrier.com Website: edwardsfiresafety.com 8985 Town Center Pkwy Bradenton, FL 34202 © 2020 Carrier JI rights reserved. Temperature (UL): -20 to . 158 °F(-29 to 70°C). Operating Temperature (ULC): -4 to environment 120 °F (-29 to 49 °C) Relative humidity: 10 to 93%, noncondensing Agency listings UL, ULC, CSFM, FM, MEA Page 4 of 4 Ordering Information Catalog Number Description Ship Wt., lb. (kg) SlGA-SD Intelligent SuperDuct Detector 2.4(l.1) Accessories SD-T8 8-inch sampling tube 0.5 (0.2) SD-Ti 8 18-inch sampling tube 1.5 (0.7) SD-T24 24-inch sampling tube 2.7(1.2) SD-T36 36-inch sampling tube 3.0(1.4) SD-T42 42-inch sampling tube 3.5(1.6) SD-T60 60-inch sampling tube 5.8 (2.6) SD-T78 78-inch sampling tube 7.5 (3.4) SD-Ti 20 120-inch sampling tube 11.5 (5.2) SD-PH Protective housing for high humidity environments 5.5 (2.5) SIGA-LED Remote alarm LED 1.0(0.5) SD-TAM Remote test station, magnetic 1.0(0.5) SD-TRK Remote test station, keyed 1.0(0.5) SD-VTK Air velocity test kit (stoppers only, etc) 1.0(0.5) SD-GSK Cover gasket kit 0.5 (0.2) SD-MAG Test magnet kit 0.5 (0.2) SIGA-SDPCB Replacement PCB/Signature sensor kit 1.0 (0.5) DATA SHEET E85001-0584 Not to be used for installation purposes. Issue 1.1 SD-TRK, SD-TRM Remote Test Stations Product description SD-TRK SD-TRM The SD-TRK and SD-TRM remote test stations are used with SuperDuct series of conventional two-wire and Signature duct smoke detectors. Each remote test station provides a red LED to indicate alarms. The SD-TRK requires a key to activate the test function while the SD-TRM requires the SD-MAG magnetic test tool (ordered separately). For operating instructions, refer to the following documentation: SuperDuct Conventional Two-Wire Duct Smoke Detector Technical Reference (P/N 3100737) SuperDuct Signature Duct Smoke Detector Technical Reference (P/N 3100738) Specifications Compatible electrical boxes North American 1-gang box Standard 4-in square box, 1-1/2 inches deep, with 1-gang cover LED indicators: Alarm (red) LED type: Clear lens Wire size: 12 to 22 AWG Resistance per wire: 10 0, max. Current requirements: Included in controller specification LED circuit ratings Voltage: 3 Vdc, max. Current: 30 mA, max. Switch ratings (SD-IRK) Voltage: 125 Vdc, max. Current: 4 A, max. Switch ratings (SD-TRM) Voltage: 200 Vdc, max. Current: 0.5 A, max. Compatible detectors: SuperDuct conventional two-wire and Signature duct smoke detectors Operating environment Temperature: 0 to 55 °C (32 to 131 °F) Humidity: 93% RH, noncondensing Storage temperature: -20 to 60 °C (4 to 140 °F) Installation instructions Mount the remote test/reset station on a single gang box as shown in Figure 1. Figure 1: Installation diagram Wiring diagram Wire the remote test station to the duct smoke detector as shown in Figure 2. -184 ri -@i -L!J 2-wire duct smoke detector Remote test station ( view) 13 © 10 JJ Signature duct smoke 1234 detector 1234 © Figure 2: Wiring diagram Installation Sheet 22SEP04 P/N: 3100691 REV: 1.0 SD-TRK, SD-TRM - Remote Test Stations 1 / 1 OFFSET SPEC SD-TRK, SD-TRM 0 Remote Test Stations For: letter, portrait to 1/4 One 8-1/2 in x 11 in sheet printed on one side. Material is standard white offset stock. Characters are black on white background. Fold two times to the dimensions shown, with the part number on the outside. DOMONVY P/N: 000000 REV: 0.0 0/0 4-1/4 in (± 1/16 in) ECO: 04-S3821 Offset Spec 22SEP04 P/N: 3100691 REV: 1.0 SD-IRK, SD-TRM - Remote Test Stations 1/1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3242-1657:0223 Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero©carrier.com DESIGN: Models ESD-SJ, ESD-ST, TSD-SJ, TSD-ST, TSD-SJG, TSD-SJCO2, TSD-STCO2, SlGA-SD, SD-2W, ESD-2W, E-PDD, and FX-PDD photoelectric type duct smoke detectors. The duct detector consists of a thermoplastic enclosure, recognized component printed wiring board, a listed duct detector subassembly, and an inlet coupling tube and an exhaust tube along with gaskets. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15.2-19.95 VDC 16-30 VDC: SD-2W, ESD-2W INSTALLATION: In accordance with listee's printed installation instructions and applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric type, duct smoke detectors for use with separately listed compatible fire alarm control units in conjunction with Models ESD-CJ, -CT or TSD-CJ, -CT series duct smoke detector controller (CSFM Listing No. 3240-1657:225). Models SIGA-SD, E-PDD, FX-PDD, SD-2W or ESD-2W does not require a listed duct smoke detector controller. Suitable for use in ducts where air velocity is between 100 and 4000 ft/mm. *Models ESD-SJ, ESD-ST, TSD-SJ, TSD-SJG, TSD-SJCO2, SlGA-SD, SD-2W and ESD-2W are suitable for use in ambient temperatures of -4°F to 158°F. Refer to listee's Installation Instruction Manual for details. NOTE: 1. CO2 sensing features were not examined. 2. Formerly 3242-1591:223 *Corrected 3-22-13 BH This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM is LISTING SERVICE LISTING No. 7300-1657:0226 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models SD-TRK, SD-TRM, SD-TRK4 and SD-TRM4 remote test/retest station. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name or Telaire, model number, electrical rating, and UL label. APPROVAL: Listed as remote test/retest station for use with listee's separately listed duct smoke detector controller subassemblies (CSFM Listing No. 3240-1657:225). Models SD-TRK4 and SD-TRM4 are for use with Models ESD-CJ, -CT or TSD-CJ, -CT series: Models Models SD-TRK and SD-TRM are for use only with Models SIGA-SD, *ESD..2W and *SD2w For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1591:226 [IJ 7-29-10 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division