Loading...
HomeMy WebLinkAbout5940 DARWIN CT; ; FPC2021-0038; PermitPERMIT REPORT city of Cdisbad Print Date: 06/21/2021 Job Address: 5940 DARWIN CT, CARLSBAD, CA 92008-7395 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: Track #: Valuation: $294,082.73 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check U: Permit No: FPC2021-0038 Status: Closed - Finaled Fixed Extinguishing Syste Applied: 03/25/2021 Issued: 04/08/2021 Finaled Close Out: 06/21/2021 Inspector: Final Inspection: Project Title: Description: PRATT & WHITNEY -REVISED PLANS TO INSTALL ANEW PRE-ACTION FIRE SUPPRESSION SYSTEM FPContractor: COSCO FIRE PROTECTION INC 1O75W LAMBERT RD BREA, CA 92821-2944 (858) 444-2000 FEE AMOUNT FIRE Special Equipment (Ovens, Dust, Battery) $417.00 FIRE TI Fire Alarm System $620.00 Total Fees: $1,037.00 Total Payments To Date: $1,037.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov San Diego Branch Office •••••• I ISCJ 4990 Greencraig Lane .00000:: San Diego, CA 92123 (858) 444-2000 fax: 444-2056 Fire Protection State License No: C-16 & C-10-5 77621 www.coscofire.com MATERIAL SUBMITTAL PRE-ACTION SYSTEM Date: 03-24-21 PRATT & WHITNEY CARLSBAD T.I. 5940 DARWIN COURT CARLSBAD, CA. 92008 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. . Submitted By: J. LEO Los Angeles 0 San Francisco • Orange • Fresno 0 San Diego • Seattle (MRP-2001(E) Deluge - Preaction Control Panel DF-60237:C1 • A2-300 (2) FlreuTe0ALarms S by Honeywell Conventional General - S The MRP-2001 is a six-zone FACP for single and dual hazard deluge and preaction applications. The MRP-2001 provides reliable fire detection, signaling and protection for commercial, industrial and institutional buildings requiring water-based releasing. The MRP-2001 is compatible with System Sensor's i detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory freeze' signal when the ambient temperature falls below the detector rating of approximately 45°F (7.220C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterfiow devices, tamper switches and other normally-open contact devices. Refer to the Fire'Lite Device Compatibility Document for a complete listing of compatible devices. Four outputs are programmable as NACs (Notification Appli- ance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The MRP-2001 supervises all wiring, AC voltage, battery charger and battery level. Activation of a compatible smoke detector or any normally- open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm infor- mation on the panel's LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function. The MRP-2001E offers the same features as the MRP-2001 but allows connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and 240 VAC versions of the panels. Features Listed to UL Standard 864, 9th edition. FM Approved. Designed for sprinkler standards NFPA 13, 15 and 16. Dual hazard operation. Adjustable waterflow discharge timer and two soak timers. Cross-zone (double-interlock) capability. Six programmable Style B (Class B) lDCs (Initiating Device Circuit). System Sensor i3 series detectors compatible. Four programmable Style Y (Class B) output circuits - (spe- cial application power). Strobe Synchronization: - System Sensor - Wheelock - Gentex - Faraday - Amseco Three programmable Form-C relays. 7.0 amps total 24 VDC output current. Resettable and non-resettable output power. Built-in Programmer. ANN-BUS for connection to optional devices (up to 8 total of any of the following): - ANN-80 Remote LCD Annunciator - ANN-I/O LED Driver - ANN-S/PG Printer Module - ANN-RLY Relay Module - ANN-LED Annunciator Module 80-character LCD display (backlit). Real-time clock/calendar with daylight savings time control. History log with 256 event storage. Piezo sounder for alarm, trouble and supervisory. 24 volt DC operation. Low AC voltage sense. Outputs Programmable for: - Releasing circuits or NACS NACs programmable for: - Silence Inhibit - Auto-Silence - Strobe Synchronization - Selective Silence (horn-strobe mute) - Temporal or Steady Signal - Silenceable or Non-silenceable - Release Stage Sounder Disable/Enable control per input zone and output zone. Extensive transient protection. Automatic battery charger with charger supervision. Optional Dress Panel DP-51050 (red). Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet. Optional CAC-5X Class A Converter Module for Outputs and lDCs. DF-60237:C1 • 12/18/12 - Page 1 of 4 S Optional 4XTMF Municipal Box Transmitter Module. Optional Digital Alarm Communicators (411 411 LID, 411UDAC). PROGRAMMING AND SOFTWARE: Custom English labels (per point) may be manually entered or selected from an internal library file. Three programmable Form-C relay outputs. Pre-programmed and custom application templates. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. USER INTERFACE: Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings adjustments. ANN-Bus for connection to remote annunciators. Audible or silent walk test capabilities. Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS FIRE ALARM (red) SUPERVISORY (yellow) TROUBLE (yellow) AC POWER (green) ALARM SILENCED (yellow) DISCHARGE (red) CONTROL BUTTONS ACKNOWLEDGE ALARM SILENCE SYSTEM RESET (lamp test) DRILL AC Power —TB1 MRP-2001: 120 VAC, 60 Hz, 3.66 amps. MRP-2001E: 240 VAC, 50 Hz, 2.085 amps. Wire size: minimum #14 AWG (2.0 mm2) with 600V insula- tion. Supervised, nonpower-limited. Battery (sealed lead acid only) - J12: Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ 1.4 amp. Supervised, nonpower-limited. Maximum Charger Capacity: 26 Amp Hour battery (two 18 Amp Hour batteries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55). Minimum Battery Size: 7 Amp Hour. Initiating Device Circuits - TB4 and TB6 Alarm Zones 1 - 5 on TB4. Alarm Zone 6 on TB6. Supervised and power-limited circuitry. Style B (Class B) wiring with Style D (Class A) option. Normal Operating Voltage: Nominal 20 VDC. Alarm Current: 15 mA minimum. Short Circuit Current: 40 mA max. Maximum Loop Resistance: 100 Ohms. End-of-Line Resistor: 4.7K Ohms, 1/2 watt (PN 71252). Standby Current: 4 mA. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Notification Appliance and Releasing Circuit(s) - TB5 and TB7 Four Output Circuits. Style Y (Class B) or Style Z (Class A) with optional con- verter module. Special Application power. Supervised and power-limited circuitry. Normal Operating Voltage: Nominal 24 VDC. Maximum Signaling Current: 7.0 amps (3.0 amps maxi- mum per NAC). End-of-Line Resistor: 4.7K Ohms, 1/2 watt (PN 71252). Max. Wiring Voltage Drop: 2 VDC. Refer to the Fire•LiteDevice Compatibility Document for com- patible listed devices. Form-C Relays - Programmable - TBS Relay 1 (factory default programmed as Alarm Relay). Relay 2 (factory default programmed as fail-safe Trouble Relay). Relay 3 (factory default programmed as Supervisory Relay). Relay Contact Ratings: —2 amps @ 30 VDC (resistive) - 0.5 amps @ 30 VAC (resistive) Auxiliary Trouble Input - J6 The Auxiliary Trouble Input is an open collector circuit which can be used to monitor external devices for trouble conditions. It can be connected to the trouble bus of a peripheral, such as a power supply, which is compatible with open collector cir- cuits. Special Application Resettable Power - TB9 Operating Voltage: Nominal 24 VDC. Maximum Available Current: 500 mA - appropriate for powering 4-wire smoke detectors (see note 1). Power-limited Circuitry. Refer to the Fire'Lite Device Compatibility Document for com- patible listed devices. NOTE: 1. Total current for resettable power, nonresettable power and Output Circuits must not exceed 7.0 amps. Special Application Resettable or Nonresettable Power - TB9 Operating Voltage: Nominal 24 VDC. Maximum Available Current: 500 mA (see note 1). Power-limited Circuitry. Jumper selectable by JP31 for resettable or nonresettable power. Refer to the FiresLite Device Compatibility Document for com- patible listed devices. Page 2 of 4— DF-60237:CI • 12/18/12 Product Line Information MRP-2001: Six-zone, 24 volt Del uge-Preaction Control Panel (includes backbox, power supply, technical manual, and a frame & post operating instruction sheet) for single and dual hazard deluge and preaction applications. MRP-2001E: Same as above but allows connection to 240 VAC. NOTE: For ULC-listed model, see DF-60441. CAC-5X: Class A Converter Module can be used to convert the Style B (Class B) Initiating Device Circuits to Style D (Class A) and Style Y (Class B) Output Circuits to Style Z (Class A). NOTE: Two Class A Converter modules are required to convert all four Output Circuits and six Initiating Device Circuits. 4XTMF: Transmitter Module provides a supervised output for local energy municipal box transmitter and alarm and trouble reverse polarity. It includes a disable switch and disable trouble LED. ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD dis- play. Recommended wire type is unshielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclo- sure (see DF-60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241). ANN-RLY: Relay Module, which can be mounted inside or out- side the cabinet, provides 10 programmable Form-C relays. (See DF-52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) . ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) DP-51050: Dress panel (red) is available as an option. The dress panel restricts access to the system wiring while allow- ing access to the membrane switch panel. TR-CE: Trim-ring (red) is available as an option. The trim-ring allows semi-flushing mounting of the cabinet. BB-26: Battery box, holds up to two 26 Amp Hour batteries and CHG-75. BB-55: Battery box, houses two 55 Amp Hour batteries. BAT Series Batteries: Refer to DF-52397. PRN-6F: UL-listed compatible event printer. Dot-matrix, trac- tor-fed paper, 120 VAC. PRT-PK CABLE: Programming cable. Used to update the FACPs Flash firmware. (Also requires an R5485 to RS232 converter). DF-60237:C1 • 12/18/12 - Page 3 of 4 SYSTEM SPECIFICATIONS [I System Capacity Annunciators ......................................................................8 Electrical Specifications MRP-2001 (FLPS-7 Power Supply): 120 VAC, 60 Hz, 3.66 amps. MRP-2001E (FLPS-7 Power Supply): 240 VAC, 50 Hz, 2.085 amps. Wire size: minimum 14 AWG (2.0 mm2) with 600 V insula- tion, supervised, nonpower-limited. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82 (42.73 cm.) wide x 0.72 (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR- CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Dimensions: - Height 20.00" (50.80cm) - Width 22.50" (57.15cm) - Depth 8.50" (21.59cm) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 490C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 270C/60 - 80°F. NFPA Standards The MRP-2001(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - NFPA 13 Installation of Sprinkler Systems - NFPA 15 Water Spray Fixed Systems - NFPA 16 Deluge Foam-Water Sprinkler and Foam-Water Spray Systems - NFPA 72 National Fire Alarm Code for Local Fire Alarm Systems and Remote Station Fire Alarm Systems (requires an optional Remote Station Output Module) Agency Listings and Approvals The listings and approvals below apply to the basic MRP- 2001(E) and MRP-2001(E)E fire alarm control panels. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for lat- est listing status. UL: S624 FM approved CSFM: 7165-0075:0216 MEA: 333-07-E NOTE: For ULC-listed model, see DF-60441. FireLite® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. -1=1 We cannot cover all specific applications or anticipate all requirements. 001181111S AMMMENS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4of4—DF-60237:C1 .12/18/12 1 0 11MI-Ell I Installation of Optional Modules Installation . 2.6 Installation of Optional Modules WARNING: RISK OF ELECTRICAL SHOCK AND EQUIPMENT DAMAGE + DISCONNECT ALL SOURCES OF POWER (AC AND DC) BEFORE INSTALLING OR REMOVING ANY MODULES OR WRING 2.6.1 CAC-5X Class A Converter Module Installation The CAC-5X Module can be used to convert five Style B (Class B) Initiating Device Circuits to Style D (Class A) and the two Style Y (Class B) Notification Appliance Circuits to Style Z (Class A). Two CAC-5X Modules are required to convert all Output Circuits and/or Initiating Device Cir- cuits to Class A. The modules plug into connector J2 which is located at the top left of the main cir- cuit board and J7 which is located at the top center of the main circuit board. To install the CAC-5X, remove the two main circuit board mounting screws referenced in the fol- lowing illustration and replaóe with the two supplied male/female standoffs in the locations indi- cated in the following figure. Carefully align the connector on the CAC-5X with J2 on the FACP main circuit board and press the module securely into place. Make certain the pins are properly aligned to prevent bending or breaking of any connector pins. Secure the CAC-5X to the standoffs with the screws that were just removed. To install the second CAC-5X on 17, remove the main circuit board mounting screw referenced in the following illustration and replace with the supplied male/female standoff. Insert the supplied plastic standoff in the location indicated in the following illustration. Carefully align the connector on the CAC-5X with J7 and press the module securely into place. Make certain the pins are prop- erly aligned to prevent bending or breaking of any connector pins. Secure the CAC-5X to the metal . standoff with the screw that was just removed. Installation on J2 Connector Installation on J7 Connector Main Circuit Board Figure 2.13 CAC-5X Module Installation MRP-2002 Series Instruction Manual- PIN 53049:E6 1/26/2017 31 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (165-0075:0216 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: ModelstMRP-2Ô01, MRP-2001E, MRP-2002, and MRP-2002E conventional fire alarm control unit. Each unit employ six programmable input circuits, four programmable output circuits, and three relay contact outputs for alarm, trouble, and supervisory signals. These units do not contain an integral digital alarm communicator transmitter (DACT). The "E" suffix represents 240 V ac 50 Hz rated units. Models MRP-2001 and MRP-2001 E are intended for water release, deluge, and pre-action control. Models MRP-2002 and MRP-2002E are intended for agent release control. FLPS-7 Power Supply module 4XTMF Transmitter moduI CAC-5x Converter module ANN-80 LCD Annunciator ANN-1 I 0 LED Driver module ANN-LED Annunciator module ANN-RLY Relay module ANN-S / PG Serial/Parallel printer module DP-51050 Dress panel DP-5105OLED Dress panel RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use as a pre action, deluge and agent releasing panel. Units also provide fire detection, signaling and protection features. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: 08-07-07 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 0 Date Issued: July 01, 2020 Listing Expires ',June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division IINj7iERSi77AijEi IB 'qq JJ IE Outrageously Dependable — ni rni w.0 i.i Chemistry: SEALED LEAD ACID (AGM) C Voltage: 12.00 Milliamp hours: 0 mAH Capacity: 12.00AH Weight: 8.05 lb Length: 5.94 in Width: 3.86 in Height: 3.66 in Termination: .187" FASTON SPADES Warranty: 12 MONTH FREE W/RECEIPT Do not crush, puncture, short external contacts or dispose of in fire or water. Replace only with the battery pack designated for this product. Do not attempt to disassemble, open, or service the battery pack. lnterstateBatteries.corn Specifications are subject to change without notice. 0 Interstate Battery Systems ofAmerica, Inc 10/25/2017 SYSTEM SENSOR System Sensor /3" series smoke detectors represer significant advancement in conventional detecti Photoelectric Smoke Detectors The i3 family is founded on three principles: instal, ... ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings S MEAMSFM C )US approved approved LISTED 5911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation ease.The i3 line redefines installation ease with its plug-in design.This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base.The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. P detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the il line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i protocol.The SENS-RDR, a wireless device, displays the sensitivityofi3 detectors in terms of percent-per-foot obscuration. Instant inspection. The 13 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire j3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. (h Smoke Detector Specifications Smoke detector shall be a System Sensor P Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical1I11IiTTh.i,i. Operating Voltage Nominal: 1 2/24V non-polarized Minimum: 85V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 qA'maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current ire:130rnlimited by control panel; 4-wire: 20 mA @12V, 23 mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @30 V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 63 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2VVT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RI-I non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2VVT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.50/o/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Red LED Condition Duration Powerup Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Orderina Information 2W-B No 12-wire 1130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max, limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24V 4W7-B Yes 4-wire 20 mA @ 12V, 23 mA@ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SEN S-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter . SYSTEM 3825 System Sensor. 3825 Ohio Avenue. St. Charles, IL 60174 Productpec0c000rssobjeottochongewohoot notice. visit systeroseasor oro for 4 SENSOR Phone: 800-SENSOR2• Fax: 630-377-6495 current producttrrforrntr-,orck,dorg the latest verconof this dutocheet Page 1 of I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. ç7272-1653:0152' CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Mode142W4, 2W1-B, 4W-B, and 4W1-B photoelectric type smoke detectors. Models 2W-B and 2W1-B are 2-wire and models 4W-B and 4W1-B are 4-wire detectors. Models 2Wr-B and 4W1-B employ a thermistor type heat sensor (135°F). The heat sensor is supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. *The above models comply with UL 268, Seventh Edition RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 *Revision 09-21-20 VWN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division SYSTEM $ SENSOR® SSM/SSV Series Alarm Bells System Sensor's SSM and SSV series alarm bells are low current, high decibel notification appliances for use in fire and burglary systems or other signaling applications. Features Approved for indoor and outdoor use • Low current draw High dB output Available in six-inch, eight-inch, and ten-inch sizes AC and DC models DC models polarized for use with supervision circuitry Mount directly to standard four-inch square electrical box indoors SSM and SSV series come pre-wired Reliable Performance. The SSM and SSV series provide loud resonant tones. The SSM series operates on 24VDC and are motor driven, while the SSV series operates on 120VAC utilizing a vibrating mechanism. Simplified Installation. For indoor use, the SSM and SSV series mount to a standard four-inch square electrical box. For outdoor applications, weatherproof back box, model number WBB, is used. The SSM and SSV series come pre-wired, to reduce installation time. The SSM series incorporates a polarized electrical design for use with supervision circuitry. Agency Listings LISTED• APPRWED S4011 CS549 3005255 7135-16530125 SSMISSV Specifications . Model shall be a SSM or SSV Series alarm bet. Bells shall have underdome strikers and operating mechanisms. Gongs on said bells shall be no smaller than nominal 67871 0- (specify size) with an operating voltage of 24VDC or 120VAC (specify by part number). Bells shall be suitable for surface or semi-flush mounting. Outdoor surface mounted installations shall be weatherproof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4" square electrical box having a maximum projection of 21/2". Bells shall be located as shown on the drawings or as determined by the Authority Having Jurisdiction. Bells shall be listed for indoor/outdoor use by Underwriters Laboratories and the California State Fire Marshal, and approved by Factory Mutual and MEA. Physical/Operating Specification Operating Temperature Range —31°F to 140°F Operating Voltage SSM series: 24 VDC SSV series: 120 VAC Termination Provided with 2 sets of leads for in/out wiring Service Use Fire Alarm, General Signaling, Burglar Alarm Warranty 3 years Electrical Specifications Model Gong Diameter Nominal Voltage Operating Voltage Maximum Current Sound Output (dBA) (inches) Limit 'SSM246 C6 lRegulated 24VDC (16 to 33VDC (bC311mN FWR-53.5 82 55M24-8 8 Regulated 24VDC 16 to 33VDC DC-31 .1 mN FWR-53.5mA 80 S5M24-10 10 Regulated 24VDC 16to33VDC DC-31.1mA/FWR-53.5mA 81 SSV120-6 6 Regulated 120VAC 96t0 132VAC 53mA 85 SSV120-8 8 Regulated 120VAC 96t0 132VAC 53mA 82 SSV120-10 10 Regulated 120VAC 96to132VAC 53mA 82 * Sound output measured at Underwriter Laboratories, as specified in UL464 Ordering Information UUFM Model No. ULC/Canadian Model No. Description SSM24-6 S5M24-6A Bell, 6' 24VDC, Polarized, 82dBA SSM24-8 SSM24-8A Bell, 8, 24VDC, Polarized, 80dBA 55M24-10 SSM24-10A Bell, 10", 24VDC, Polarized, 81dBA SSV120-6 SSV120-6A Bell, 6' 12OVAC, 85dBA SSV120-8 SSV120-8A Bell, 8", 12OVAC, 82dBA SSV120-10 SSV120-10A Bell, 10' 120VAC, 82dBA WBB Weatherproof back box for SSM and SSV series, when installed outdoors SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2O12SysteroSensor. for current product information, including the latest version of this data sheet. 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change whhout notice. Visit systerrrsensorcom www.systemsensor.com WFDS74501 • 3112