Loading...
HomeMy WebLinkAbout1340 POINSETTIA LN; ; FA070057; Permit5/27/2021 FA070057 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA070057 1340 POINSETTIA Job Address: Status: ISSUED LN Permit Type: FALARM Applied 6/7/2007 Parcel No: 2150704700 Approved: 6/7/2007 Lot #: 0 Reference No.: Issued: 6/7/2007 PC #: Inspector: Project Title: NORTH COAST CALVARY CHAPEL Applicant: EMCOM ELECTRONIC SYSTEMS, INC SUITE H 256 WITH ERSPOON WY ELCAJON,CA 619-667-1200 Owner: CALVARY CHAPEL NO COAST 7188 AVENIDA ENCINAS CARLSBAD CA L Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 1/1 I EMCOM I ELECTRONIC SYSTEMS, INC. CALIC.820216 SEC. LICACO3B38 256 WITHERSPOON WAY, SUITE H ELCAJON, CA 92020 • PH. (619) 667-1200 • FAX (619) 667-1222 I I I Fire Alarm System I Equipment Submittals I I for I North Coast Calvary Chapel C-hi Idre n'sM in istrreente r== 7188 Avenida Encinas Carlsbad, CA 92009 I I I ** ATTENTION ** Carlsbad Fire Department requires Double- Action initiating devices in all common use or Publicly Accessible areas. ATTENTION: CAT 45 key / locksets are to be used on all Cabinets and Appliances that utilize a cam lock. APPRO)1S SUBMITTED W/M6 5 7f 4't CARLSBADIIRE DEPARTMENT I I I I I I ri- o7o57 APPROVEDc.) -01"07 F-1 APPROVED AS NOTED [j NOT APPROVED, RESUBMIT cHECcNc IS ONLY FOR COFORMANO T:R. DSC! CP1 THE HE IN THE UOiFACT c):UEiS. COflHACTGH IS RESPONSIBLE OS 10 EE CONIRRMED I OR;l[LiED AT THE JOB SHE AND FOR COORDINATION OF THE WORK OF ALL TRADES. Features — — — — — — — — — — — — — — — — E — — — — — — — — — — — — — — — — o u] Description Mircom's FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements while also providing easy installation and operation at a cost- effective price. The FX-2000 base panel consists of one intelligent analog loop controller capable of supporting 99 Analog Sensors and 99 Addressable Modules which can be wired in Class A(Style 6 or 7) or Class B (Style 4). The system can be expanded by adding additional Analog Loop Controller Modules. In addition the base panel supports 16 conventional hardwire adder modules such as the DM-1 008A Initiating Circuit Module, SCM- 1004A Indicating Circuit Module and the RM-1008A Relay Circuit Module. Additional conventional hardwire adder modules can be added with the ALC-H1 6 Adder Hardwire Loop Controller Module, which allows the system to support an additional 16 conventional adder modules. The base panel also consists of 4 Class A/B (Style ZIY) Indicating Circuits rated at 1.7 Amps each and either a 6 or 12 Amp Power Supply. Equipped with a large 4 x 20 Back-lit Alphanumeric LCD display, the FX-2000 utilizes a simple Menu system complete with a directional keypad, common control switches and LEDs, Alarm Queue switches and LEDs, two configurable input switches and 16 configurable zone LEDs. Large system capacity Modular design Each Analog Loop is capable of supporting 99 Analog Sensors and 99 Addressable Modules which can be wired in Class A (Style 6 or 7) or Class B (Style 4) Base system supports 16 conventional hardwired modules with the provision to add more using the ALC- H16 Hardwire Loop Controller Module 6 or 12 Amp power supply Four Class A/B (Style Z/Y) Indicating Circuits rated at 1.7 Amps each Configurable for Two Stage operation Three level password protection with field programmable definition which enables the installer to determine what functions are accessible for each password level Panel Security to protect site configurations Manual Control Enable which allows password protection for all front panel function switches Correlatable Switch Inputs which allows for multi- functional outputs Four Alarm Queues with selector switches and LEDs for Alarm, Supervisory, Monitor and Trouble Auxiliary relay contacts for Common Alarm, Common Supervisory and Common Trouble RS-232 output for remote system printer or CRT Two Event History Logs comprised of a 1000 Alarm History Log for alarm related events and a 2000 Event Log for all events Front Panel Auto-Configure and/or Computer laptop Programmable Large 4 by 20 character Back-lit LCD Display with user friendly menu Common Control switches and/or indicating LEDs for System Reset, Signal Silence, Fire Drill, Acknowledge, General Alarm, Lamp Test, A.C. On, Pre-Alarm and Ground Fault Built-in One Man Walk Test operation Configurable for Coded Operation 16 zone configurable LED annunciator complete with individual slide-in labels for zone definition Supports an RS-485 interface to the QX-5000 Voice Evacuation System Panel selection for Canadian (ULC) or U.S.A. (UL) requirements for smoke sensors (sensitivity) via computer laptop Capability to adjust Intelligent Smoke Detector sensitivity level City of I& @ .: 3013980 Chicago PJI EA Class I (Con) E15095 Class II (Con) E15096 S7010 S7010 7165-1477:111 approved Classl(Add) E15097 Class II (Add) E15098 7170-1477:119 313-97-E l-Hghiise I I I I I I I I I I I I I I I CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reservas the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. I Operation The FX-2000 is field programmable via the front panel auto configuration or a laptop computer. In addition, it allows for a three level password protection that can be field defined via a laptop computer. This unique feature allows the installer to determine what functions are accessible for each password level. The system is also equipped with two Event History Logs; one for Alarm and the other for full panel sequence events. The Alarm History Log (1000 events) contains all alarm related functions while the Event Log (2000 events) provides a full sequence log of all operations, as well as alarms and troubles. Both Event History Logs can be used during the One Man Walk Test operation. This allows the event logs to be downloaded to a laptop or printer for a permanent record. The FX-2000 is a very flexible system which supports both internal and external annunciation modules. The internal annunciation modules consist of the RAX-1048 Programmable Zone LED Annunciator, the lPS-2424 Programmable Input Switches Module, the FDX-008 Fan Damper Module and the AGD-048 Adder Graphic Driver Module. Input Correlations All input circuits (addressable or hardwired) can be configured for non-verified alarm, verified alarm, waterflow, latching/non-latching supervisory, monitor, trouble only or remote switch inputs. All of the input configuration types listed above, with the exception of remote switch can be programmed to operate relays, signal and strobe circuits for hardwired or addressable devices. Please refer to the chart below for correlations. The input circuits configured as non- latching will cause the output circuits configured to them to follow the state of the input device. This feature allows for the connection of multiple panels together for signal operation. All of these modules mount within the panel and are driven from the main LCD display. The external annunciator modules include the RAM-1032 and RAX-1048 LED Remote Annunciators, the MGD-32 Master Graphic Driver Module, the MGDS-16/16 Master Graphic Driver Module and the RAX-LCD Remote LCD Shared Display. The RAX-LCD Remote LCD Shared Display provides the same features as the main display on the FX-2000. In addition the RAX-LCD also acts as a driver module that allows forthe RAX-1048, lPS-2424, FDX-008 andAGD-048 to be connected to it. The RAX-LCD is required as a driver module any time any of the above mentioned external annunciator modules are programmed differently from those on the main panel or are mounted remote from the main panel. In addition to these adder modules, the FX-2000 also supports the UDACT-300A Digital Communicator Module and the PR-300 Polarity Reversal/City Tie Module. The FX-2000 also supports an RS-485 interface to the QX-5000 Emergency Zoned Audio System. The Remote Switch input, which must be momentary, allows any input type device (addressable or hardwired) to be configured as a common control functions such as fire drill, system reset, signal silence etc. The remote switches operate in a momentary mode like the control switches on the FX- 2000 main panel. For functions such as fire drill, the remote switch functions in a toggle mode, with one press for on" and one press for 'off'. The remote switch is supervised for "stuck in on" positions, where the switch input is activated (stuck) for more than 30 seconds. If this occurs, a trouble is generated and clears when the input goes away. I I I I I I I I I I I I Intelligent or Conventional Input Types Output Control Switches Strobe Relay Signal Non-Verified Alarm Yes Yes Yes No Verified Yes Yes Yes No Waterfiow Yes Yes Yes No Non-Latching Supervisory Yes Yes Yes No Latching Supervisory Yes Yes Yes No Monitor Yes Yes Yes No Trouble Only Yes Yes Yes No Remote Switch Input No No No Yes I I I I I I iuic _! ® NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 2 of 10 I I I I FX-2000 Standard Series I I FX-2003-6/FX-2003-12 Compact Main Chassis The FX-2003-6/FX-2003-12 Compact Main Chassis comes complete with one Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 Class NB (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and either a 6 Amp Power Supply which charges 10-24 AH batteries or a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2003-6/FX- 2003-12 supports 16 conventional adder modules and provides space for 3 adder modules. The FX-2003- 6/FX-2003-12 mounts in the BBX-1024 enclosure. FX-2017-12A Mid-Size Main Chassis The FX-2017-12A Mid-Size Main Chassis comes complete with one Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 Class NB (Style ZIY) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-2017- 12A supports 16 conventional adder modules and has space for up to 17 adder modules and 3 internal annunciator adder modules. The FX-201 7-1 2A mounts in the BBX-1072A enclosure. FX-2009-12 Large Size Main Chassis The FX-2009-12 Large Size Main Chassis comes complete with one Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40AH batteries. The FX-2009-12 supports 16 conventional adder modules and provides space for up to 9 adder modules and 2 internal annunciator adder modules. The FX-2009-12 mounts in the 1313- 5000 Series enclosures. ECX-0012 Expander Chassis The ECX-001 2 Expander Chassis for the FX-2009-1 2/ FX-20095-12 supports up to 12 adder modules and has space for 2 internal annunciator modules. The ECX- 0012 mounts in the BB-5000 series enclosures. FX-2000 Standard Series System Maximums 500 Input Circuits 150 Output Circuits 5 Intelligent Addressable Loops 4 Remote LCD Annunciators 4 Main LED Annunciators 100 Manual Control Switches NOTE: Refer to page 4 for Enhanced Series Maximums I I .1 1 I I I 111111ii, MIRQi NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 3 of 10 FX-2000 Enhanced Series Mircom's FX-2000 Enhanced Series feature a powerful CPU which increases the processing of inputs/outputs to provide faster response times and allow for larger system capacities. The Main Chassis are available in the same configurations as the standard FX-2000 Series. I I I I FX-2003S-12 Enhanced Series Compact Main Chassis The FX-2003S-12 Enhanced Compact Main Chassis comes complete with 4 Class A/B (Style Z/Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back- lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-20035-1 2 provides space for 3 ALC-396S Dual Loop Controller Modules. The FX-2003S-12 mounts in the BBX-1 024 enclosure. FX-2017S-12A Enhanced Series Mid-Size Main Chassis The FX-2017S-12A Mid-Size Main Chassis comes complete with 4 Class A/B (Style ZIY) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-20175-12A provides space for up to 17 adder modules/Dual Loop Controllers and 3 internal annunciator adder modules. The FX-2017S- 12A mounts in the BBX-1 072A enclosure. FX-20095-12 Enhanced Series Large Size Main Chassis The FX-20095-1 2 Enhanced Large Size Main Chassis comes complete with 4 Class A/B (Style ZfY) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display, 16 Zone LED Annunciator and a 12 Amp Power Supply which charges 17-40 AH batteries. The FX-20095-12 electrically supports 16 conventional adder modules and provides space for up to 9 adder modules and 2 internal annunciator adder modules. The FA-2009S-12 mounts in the BB-5000 Series enclosures. ECX-0012 Expander Chassis The ECX-001 2 Expander Chassis for the FX-2009-1 2/ FX-20095-1 2 supports up to 12 adder modules and has space for 2 internal annunciator modules. The ECX- 0012 mounts in the BB-5000 series enclosures. FX-2000 Enhanced Series System Maximums 1500 Input Circuits 300 Output Circuits 30 Intelligent Addressable Loops 24 Remote LCD Annunciators 4 Main LED Annunciators 300 Manual Control Switches 1 /J IiII_cQ!! CAT. 5910 NOT TO BE USED FOR INSTALLATION PURPOSES. page 40110 I Adder Loop Controller Modules Adder Hardwire Modules I ALC-198S Single Analog Loop Controller Module The ALC-198S Single Analog Loop Controller Module provides an additional analog loop to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules. The ALC-1 98S occupies one module slot in the FX-2000 main or expander chassis. ALC-396S Dual Analog Loop Controller Module The ALC-396S Dual Analog Loop Controller Module provides two additional analog loops to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules per loop. The ALC-396S occupies one module slot in the FX-2000 main or expander chassis. ALC-H16 Hardwire Loop Controller Module TheALC-H 16 Hardwire Loop Controller Module allows the FX-2000 to support an additional sixteen (16) conventional hardwire adder modules. The hardwire modules consist of the DM-1008 Eight Initiating Circuit Module, SGM- 1004 Four Indicating Circuit Module and the RM-1008 Eight Relay Circuit Module. TheALC-H16 occupies one module slot in the FX-2000 main or expander chassis. Adder Auxiliary Modules DM-1008A Eight Initiating Circuit Module The DM-1 008A provides 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits configurable for Alarm, Supervisory orTrouble zones. The DM-1 008A occupies one module slot in the FX-2000 main or expander chassis. SGM-1004A Four Indicating Circuit Module The SGM-1004A provides 4 Class A/B (Style Z/Y) Indicating Circuits configurable as Silenceable or Non-Silenceable. Each Indicating Circuits is rated at 1.7 Amps. Each of the indicating circuits have individual signal silence inputs which are jumper selectable. The SGM-1004A occupies one module slot in the FX-2000 main or expander chassis. RM-1008A Eight Relay Circuit Module The RM-1 008A provides the FX-2000 with B individual configurable relays per module. Each relay provides one Form C contact rated at 28 VDC @1 Amp (resistive load). The RM-1008A occupies one module slot in the FX-2000 main or expander chassis. I UDACT-300A Digital Alarm Communicator Module The UDACT-300A Digital Alarm Communicator Module allows the FX-2000 to transmit addressable point information to a central station. The UDACT-300A can be configured locally via the on-board keypad and the CFG- 300 Configuration Tool or with a UIMA programming tool and a computer with an available serial or USB port. The UDACT-300A occupies one module slot in the FX-2000 main or expander chassis. PR-300 Polarity Reversal/City Tie Module The PR-300 Polarity Reversal/City Tie Module provides the system with a supervised City Tie (24 VDC/200 mA max.) and Polarity Reversal connection (24 VDC (open circuit), 8 mA max. (shorted)). The PR-300 mounts in the FX-2000 main chassis. I I /J F'Nt1 0 Er ON NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 5 of 10 Programmable Modules RAX-1 048 Programmable Zone LED Annunciator Module The RAX-1 048 Programmable Zone LED Annunciator Module provides 48 programmable bi-coloured LEDs. The RAX-1048 connects to the main panel or the RAX-LCD Shared Display when mounted remotely. The RAX-1048 occupies one display position in the 1313-1000 or BB-5000 enclosures. FDX-024 Fan Damper Module The FDX-024 Fan Damper Module provides 24 individually programmable switches which can be used for fan or damper control. Each circuit has 24 Bi-Coloured LEDs (Green/Amber) and 24 Amber Select LEDs. The FDX-024 connects to main panel or the RAX-LCD when mounted remotely.The FDX- 024 occupies one display position in the 1313-1000 or BB-5000 enclosures. FDX-008 Fan Damper Module The FDX-008 Fan Damper Module provides individually programmed circuits which can be used for fan or damper control. Each circuit has a slide-in label, a three position selector switch, green "run or open" LED and an amber "off or closed" LED. The three-position selector switch has a centre "auto" position, a left "off or close" position and a right "on or open" position. The FDX-008 connects to the main panel or the RAX- LCD when mounted remotely. It uses MIX-M500CH for control of fans or dampers and two MIX-M501A for status. The FDX-008 occupies one display position in the BB-1000 or BB-5000 enclosures. IPS-2424 Programmable Input Switches Module The IPS-2424 Programmable Input Switches Module provides 24 programmable switches that can be configured for ancillary functions such as zone bypass or added common control functions. The switches operate in a toggle operation with one press for "on" and one press for "off'. The lPS-2424 connects to main panel or the RAX-LCD when mounted remotely. The IPS-2424 occupies one display position in the 1313-1000 or BB-5000 enclosures. Electrical Ratings Current Consumption Model Standby Alarm FX-2003-6/FX-2003-12 230 mA 380 mA FX-2017-12A 230 mA 380 mA FX-2009-12 230 mA 380 mA ALC-198S/ALC-396S 35 mA 50 mA ALC-H16 35 mA 50 mA DM-1008A 80 mA 100 mA SGM-1004A 35 mA 150 mA RM-1008A 25 mA 150 mA PR-300 50 mA 300 mA UDACT-300A 40 mA 60 mA RAX-LCD 100 mA 150 mA IPS-2424 10 mA 144 mA FDX-008 10 mA 100 mA MGD-32 35 mA 1.6 Amps AGD-048 25 mA 2.4 Amps RAM-1032 50 mA 150 mA RAX-1048 15 mA 100 mA CAT. 5910 page 6 of 10 I I I I I 1 I iiiiii_Q_! qD NOT TO BE USED FOR INSTALLATION PURPOSES. Remote Annunciators Graphic Annunciator Driver Modules RAX-LCD Remote Shared Display The RAX-LCD Remote Shared Display is a remote annunciator that provides the same functions as the main display on the fire alarm control panel, less the 16 zone LEDs. In addition to operating as a remote annunciator, it can also be used as a driver module for standard LED annunciation or reduced zone annunciation (different from the main panel annunciation), graphic drivers programmed different from the main annunciators, programmable switch modules with a unique configuration and fan damper control also with a unique configuration. Each time a different type of annunciation configuration is needed an additional RAX-LCD is required. The RAX-LCD occupies one display position in the 1313-1 000 or BB-5000 enclosures. RAM-1032 Main Remote LED Annunciator The RAM-1 032 Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. Each display point can be identified by the slide-in label that slides in beside the LED. The RAM- 1032 is equipped with sealed membrane-like buttons for Common Control functions. The RAM-1 032 allows for the control switches to be disabled on a per function basis for areas that do not require certain common control functions to be remotely located from the fire alarm control panel. The RAM-1032 can be programmed differently than the main panel annunciator or a remote RAX-LCD. All RAM-1 032 remote annunciators on the system must be programmed the same. The RAM-1032 occupies one display position in the 1313-1 000 or BB-5000 enclosures. RAX-I 048 Adder Remote LED Annunciator The RAX-1048 Adder Remote LED Annunciator provides an additional 48 points of LED annunciation. The RAX-1048 is an expandible module that connects to the RAM-i 032. The RA)(-i 048 occupies one display position in the 1313-1 000 or BB-5000 enclosures. MGD-32 Master Graphic Driver Module The MGD-32 Master Graphic Driver Module provides common control inputs for the common control switches such as System Reset, Signal Silence, Auxiliary Disconnect, Fire Drill, Lamp Test, Acknowledge and General Alarm. Any or all of these switch inputs can be used. There are supervised outputs for all of the support LEDs and the common control switches. The MGD-32 can also drive up to 32 supervised outputs. These output points are capable of driving LEDs or incandescent lamps. Mounts in a graphic annunciator wallbox or in the BB-5000 enclosures. External power supply required for incandescent lamps and lamp test. AGD-048 Adder Graphic Driver Module The AGD-048 Adder Graphic Driver Module can be used with either the MGD-32 or MGDS-i 6/16 Master Graphic Driver modules, or if located remotely it must be connected and mounted with the RA)(-LCD Shared Display. The AGD-048 will support an additional 48 supervised outputs. As with the master modules, the AGD-048 will support both LEDs and incandescent lamps. Mounts in a graphic annunciator wallbox or in the BB-5000 enclosures. liQI The combined total of RAM-1032 and MGD-32 per system is eight. All RA-1000 Series annunciators or Graphic driver modules must have the zoned LED or graphic LED correlated to the same combination of addressable devices orhardwired zones. However, the zoned LED annunciator on the FX- 2000 main panel can be programmed differently from the annunciators mounted remotely. I I I IN OR NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 7 of 10 0 SESSER USE MESSES F=ss 03 1• Enclosures I 1 I I BBX-1 024 The BBX-1 024 enclosure is capable of handling one FX- 2003-6 or FX-2003-1 2 Compact Main Chassis and up to 17AH Batteries. The FA-UNIV-TRB Semi-Flush Trim Ring is required for semi- flush mounting. The cabinet features the universal CAT-30 lock and a removable door for easy installation and servicing. The cabinet is available in a beige or red exterior (BBX-1024R). Dimensions: 26'H x 14 1/2"Wx4 1/2"D .--'..- :cix I—.. BB-5008 The BB-5008 is a lobby control centre enclosure which is capable of handling one FX-2009-1 2 Large Main Chassis which supports 2 internal annuciator modules such as the IPS-2424, FDX-008, RAX-1 048, etc. In addition the BB-5008 allows for 4 footprints for mounting Audio Lobby Control modules, Fire Fighter's Lobby Control modules and FX-2000 Internal Annunciator modules. The cabinet hold upto24AH batteries. Door and Chassis hardware are ordered seperately. Dimensions: 36'H x 30"Wx 7"D BBX-1 072A The BBX-1 072A enclosure is capable of handling one FX-2017-12A Mid-Size Main Chassis, as well as up to 40 AH Batteries. The cabinet features the universal CAT-30 lock and a removable door for easy installation and servicing. The cabinet is available in a beige or red exterior (BBX-1 072AR). Dimensions: 32 1/2"Hx25"Wx6 112"D BB-5014 The BB-5014 is a lobby control centre enclosure which is capable of handling one FX-2009-12 Large Main Chassis which supports 2 internal annuciator modules such as the IPS-2424, FDX-008, RAX-1048, etc. In addition the BB- 5014 allows for 10 footprints for mounting Audio Lobby Control modules, Fire Fighter's Lobby Control modules and FX-2000 Internal Annunciator modules. The BB- 5014 can also support a graphic annunciator in place of these modules. The cabinet holds up to 24 A batteries. Door and Chassis hardware are ordered seperately. Dimensions: 60"H x 30W x 7'D I I Other Enclosures BB-1001: 9"H x 12.75"Wx 1.20 BB-1002: 18"H x 12.75"Wx 1.2D BB-1003: 26.4"Hx 12.75'Wx 1.2'D BB-1008: 33'H x 22.5"Wx 1.25"D BB-1012: 45"H x 22.5"Wx 1.25'D I 111111ii, MIRQ!W I NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 8oflO Typical FX-2000 Panel Wiring Class B (Style 4) I...... Graphic Annunciator Wullboa C/w II graphic annunciator. MGD-32 II BB-1001 enclosure Master Graphic Driver II I module and AGD.048 c RAM-1032 II Adder Graphic Driver II LED Annunciator Conventional Heat Sensors 1-5 and Manual Pull Stat on =ss 4th Floor . :• I I• . — I BB-5008 enclosure c/w RAX-LCD, RAX-048, lPS-2424 and FDX-048. I Circuits Signal I 3&4 — I M500S 2Pair IM50O X vn 3rd Floor — — — — — — ---------------------- 24 VDC Riser Na a. - Reseltablo Power BB-1003 enclosure 24VDC I I RAX-LCD, RAX-048 and Riser .__. :01 I I I I lPS.2424 Resetlable Power I Conventional devices Conventional [1 3 Hardwired — -L Circuit #2 Data Loop #1 Graphic Annunciator C/w AGD.048 modules EM _______ • U L_J U Li Li Signal Circuits Conventional devices ] 3 Conventional Hardwired Indicating Circuit #1 2nd Floor — — — — — — — — ------------ I Pair for Rs.485 1 Pair for 24 VOC FX-2009-12 Large Main Chassis in a BB-5014 enclosure clw ECX-0012 Expander Chassis, RAX-048, IPS-2424, FDX-008 and AGD-048. Includes DM-1008 Conventional Indicating Circuit Modules. External power supply is required for incandescent lamps and lamp test. o =- -d j ero 1'I S...err Ss,w MSO1M a,vor ruvr I M502M] rv.ro ccuur M500S CAT. 5910 ffl-mc-om NOT TO BE USED FOR INSTALLATION PURPOSES. page 9 of 10 Ordering Information Model Description FX-2000 Standard Series FX-2003-6 Compact Main Chassis clw one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class A/B (Style ZJY) Indicating Circuits (1.7 Amps each), 16 LED annunciation points and a 6 Amp power supply. Supports up to 16 Conventional Adder Modules. Provides space for 3 Adder Modules. Mounts in the BBX-1024 enclosure. FX-2003-12 Same as above with 12 Amp Power Supply. FX-2017-12A Mid-Size Main Chassis c/w one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class A/B (Style Zn') Indicating Circuits (1.7 Amps each), 16 Red LED annunciation points and a 12 Amp power supply. Supports up to 16 Conventional Adder Modules. Provides space for 17 Adder Modules and 3 Internal Annunciation modules. Mounts in the BBX-1072A enclosure. FX-2009-12 Large Main Chassis c/w one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class A/B (Style Z(Y) Indicating Circuits (1.7 Amps each), 16 Red LED annunciation points and a 12 Amp power Supply. Supports up to 16 Conventional Adder Modules. Provides space for 9 Adder Modules and 2 Internal Annunciation modules. Mounts in the BB-5000 series enclosures. ECX-001 2 Expander Chassis for the FX-2009-12 ctw space to add up to 12 adder modules and 2 Internal Annunciation modules. Mounts in the BB-5000 series enclosures. FX-2000 Enhanced Series FX-2003S-6 Compact Main Chassis c/w 4 x 20 Back-lit LCD display, 4 ClassA/B (Style Zn') Indicating Circuits (1.7 Amps each), 16 LED annunciation points and a 6 Amp power supply. Provides space for 3 ALC-3965 Dual Loop Controller Modules. Mounts in the BBX-1 024 enclosure. FX-20035-12 Same as above with 12 Amp Power Supply. FX-2017S-12A Mid-Size Main Chassis c/w4 x 20 Back-lit LCD display, 4 Class A/B (StyleZ(Y) Indicating Circuits (1.7 Amps each), 16 LED annunciation points and a 12 Amp power supply. Provides space for 17 Adder Modules/Dual Loop Controller Modules and 3 Internal Annunciation modules. Mounts in the BBX-1072A enclosure. FX-2009S-12 Large Main Chassis ctw 4 x 20 Back-lit LCD display, 4 Class A/B (Style Zn') Indicating Circuits (1.7 Amps each), 16 LED annunciation points and a 12 Amp power supply. Provides space for 9 Adder Modules/Dual Loop Controller Modules and 2 Internal Annunciation modules. Mounts in the BB-5000 series enclosures. ECX-001 2 Expander Chassis for the FX-2009-12 ci'w space to add up to 12 adder modules and 2 Internal Annunciation modules. Mounts in the BB-5000 series enclosures. Adder Loop Controller Modules ALC-198S Single Loop Intelligent Analog Loop Controller Module (99 Analog Sensors and 99 Addressable Modules) ALC-3965 Dual Loop Intelligent Analog Loop Controller Module (198 Analog Sensors and 198 Addressable Modules) ALC-H16 Hardwire Loop Controller Module. Supports 16 Conventional Hardwired Modules. Adder Hardwire Modules OM-1008A Eight Class B (Style B) or 4 Class A (Style D) Initiating Circuit Module SGM-1 004A Four Class A/B (Style Zn') Indicating Circuit Module (Rated at 1.7 Amps per circuit) RM-1008A Eight Relay Circuit Module cfw eight form C relays (Rated for 28 VDC @ 1 Amp max. per relay) Adder Auxiliary Modules UDACT-300A Digital Alarm Communicator Transmitter/Dialer Module PR-300 Polarity Reversal and City Tie Module Programmable Modules RAX-1048 Programmable Zone LED Annunciator Module cfw 48 bi-coloured LEDs IPS-2424 Programmable Input Switches Module c/w 24 selector switches and 24 bi-coloured LEDs FDX-008 Fan Damper Control Module c/w 8 programmable switches FDX-024 Fan Damper Control Module c/w 24 programmable switches Remote Annunciators RAM-1032 Main Annunciator Chassis cfw Common Control Features, Indicators and 32 Bi-Coloured LEDs RAX-1048 Adder Annunciator Chassis c/w 48 Bi-Coloured LEDs RTI-1 Remote Trouble Indicator Remote Shared Display Annunciators RAX-LCD Remote Shared Display LCD Annunciator c/w Display Queues and Common Controls. Graphic Annunciator Driver Modules MGD-32 Master Graphic Driver Module ctw Fire Alarm Common Control Switch Inputs and 32 Supervised Outputs AGD-048 Adder Graphic Driver Module c/w 48 Supervised Outputs Enclosures BBX-1024 Black backbox enclosure for FX-2000 c/at removable door and CAT-30 lock and key. Houses one FX-2003-6, FX-2003-12, FX-20035-6 or FX-2003S-12 Compact Main Chassis and up to 17 AH batteries. White door. (Add suffix "R" for red doo, BBX-1072A Black backbox enclosure for FX-2000 c/w removable door and CAT-30 lock and key. Houses one FX-2017-12A or FX-20175-12A Mid-Size Main Chassis, and up to 40 AH batteries. White door. (Add suffix "R" for red door) BB-5008 Lobby Control Centre Wailbox Enclosure. Supports 8 Module Footprints. DOX-5008M White Metal Door for BB-5008 CCH-5008 Custom Mounting Kit for BB-5008. One required per BB-5008. BB-5014 Lobby Control Centre Wailbox Enclosure. Supports 14 Module Footprints. DOX-5014M While Metal Door for BB-5014 CCH-5014 Custom Mounting Kit for BB-5014. One required per BB-5014. FA-UNlV-TRB Universal Black Semi-Flush Trim Ring for BBX-1024 Backbox NOT TO BE USED FOR INSTALLATION PURPOSES. MIRcQr!i® Distributed by: Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 6604655 Fax: (905) 660-4113 Web page: http://www.mircom.com U.S.A. 60 Industrial Parkway Cheektowaga, New York 14227 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Email: mail@mircom.com CAT. 5910 Rev. 5 1i 7iwi aso cw-v ,,7,, 1 INTELLIGENT ADDRESSABLE PULL STATIONS MS-700ADU SERIES ** ATTENTION ** Carlsbad Fire Department requires Double- Action initiating devices in all common use or Publicly Accessible areas. Features Single or Dual Action Key resettable Permanently Attached Intelligent Addressable Module :• High-gloss red enamel finish Plastic breakrod Mounts on standard single gang box, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox MS-701ADU MS-710ADU Intelligent Addressable Intelligent Addressable Single Action Pull Station Dual Action Pull Station Description Mircom's MS-700ADu Series provide manual fire reporting. These high quality, die-cast metal Intelligent Fire Alarm Pull Stations are available in either single or dual action configurations with a permanently attached addressable module. The MS-700ADu Series stations are available as single or dual-action devices with key resets and a permanently attached addressable module . The addressable pull station has a pair of rotary decimal switches which allows for two digit address setting. Pulling the handle initiates the operation of the addressable module. All models are available with CAT-30 keys and mount on a standard single gang backbox, Mircom model BB-700 interior surface metal backbox, or BB-700WP weather proof backbox. Oration The MS-701ADU Single Action Intelligent Pull Station is operated by pulling down the handle marked PULL HANDLE" on the front of the station. The MS-710u Dual Action Intelligent Pull Station is operated by pushing the bar labelled PUSH BAR" and then pulling down the handle marked PULL HANDLE". The MS- 700ADU Series Pull Stations are reset by opening the station with the key, placing the handle in the normal upright position and re-locking the station. Specifications The manual pull station shall be Mircom's MS-700ADU Series. Operating instructions shall be in raised English lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the intelligent addressable module. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes. Final acceptance is subject to the local authority having jurisdiction. @@0 S7005 S7005 7150-1477:128 CATALOG NUMBER 5928 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Canada U.S.A. 25 Interchange Way 60 Industrial Parkway Vaughan, Ontario L41< 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: maiI@mircom.com I I I CAT. 5928 Rev. 1 I Specifications Switch Rating: Pull Station Dimensions: I Color: Current Consumption: l Amp @3OVDC 0.1 Amp @ 125 VAC 4.9" H x 3.5" W x 2.0' D Red with raised white letters, white Pull bar with raised red letters. Standby: 400 uA Alarm: 5.5 mA Surface Mount Backboxes BB-700 Surface Mount Backbox Dimensions: 5" H x 3.6" W x 2.0' D Typical Wiring Diagram MS-70IADU and MS-7I0ADU FROM RED —p PREVIOUS BLK ,TO NEXT STATION OR STATION —.4 )END OF LINE DEVICE RED { - ADDRESSABLE MODULE + RED NOTES: WIRE AS SHOWN SO THAT SUPERVISION OF CONNECTIONS IS MAINTAINED. MOUNT STATION TO 4" SQUARE x 1/2" DEEP OUTLET BOX WITH PLASTER RING RAISED 1/2". SWITCH RATING: ALL MODELS 1A@ 30VIDC, 0.1A@ 125VAC MAXIMUM WIRE SIZE: No. 12 AWG. REFER TO FIRE ALARM CONTROL PANEL MANUAL FOR ADDRESSABLE MODULE SETTING. Ordering Information Model Description MS-701ADU Intelligent Addressable Key Resettable Single Action Manual Pull Station MS-702ADU Intelligent Addressable Key Resettable Dual Stage Single Action Manual Pull Station MS-71OADU Intelligent Addressable Key Resettable Dual Action Manual Pull Station BB-700 Series 700 Interior Surface Mount Backbox, Red Finish BB-700WP Series 700 Weatherproof Surface Mount Backbox, Red Finish Add suffix "NY" for New York Versions NOT TO BE USED FOR INSTALLATION PURPOSES. M IRQi® I I I I I I I I I I I I YEL YELLOW N.C. SWITCH BB-700WP Weatherproof Surface Mount Backbox Dimensions: 5" H x 3.6" W x 2.2" D INTELLIGENT LOW PROFILE SENSORS MIX-200 SERIES Mircom's MIX-200 Series intelligent plug-in smoke detectors with integral communication provide features that surpass conventional detectors. Detector sensitivity is continuously monitored and reported to the FX-2000 Fire Alarm Control Panel. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level. Intelligent Low Profile Ionization Smoke Sensor (MIX-1 251 B) The Intelligent Ionization Smoke Sensor is constantly monitored to measure any change in its sensitivity due to the environment (dirt, aging, temperature, humidity, etc.) It can give an advance indication to the FX-2000 analog control panel of the need for maintenance and can be specific as to where the maintenance is needed. It can be mounted in a number of different bases. Seethe Ordering Information for a list of these bases and their descriptions. I ---- I _-_- Intelligent Low Profile Photoelectronic Smoke Sensor (MIX- 2251 B) The Intelligent Photoelectronic Smoke Sensor is constantly monitored to measure any change in its sensitivity due to the environment (dirt, aging, temperature, humidity, etc.) It can give an advance indication to the FX-2000 analog control panel of the need for maintenance and can be specific as to where the maintenance is needed. It can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. I I Intelligent Thermal Sensors (MIX-5251 B/MIX-5251 RBIMIX-5251 H) The Intelligent Thermal Sensors contain a dual thermistor sensing circuit for fast response. They provide open area protection with 50 foot spacing. The sensors rapid response characteristic virtually eliminates the thermal lag which is characteristic of conventional heat detectors and insures operation as soon as the temperature reaches its set point (MIX-5251 B), or upon a temperature rise of 15°F per minute (MIX-5251 RB). The MIX-5251 H provides fixed high temperature detection at 190°F. These sensors can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. Intelligent Low Profile Photoelectronic Smoke Sensor with Thermal (MIX-2251TB) The MIX-2251TB has the same features as the MIX- 2251B and includes a 135°F thermal sensor. It can be mounted in a number of different bases. See the Ordering Information for a list of these bases and their descriptions. ®MEA MSFM approved 2151 approved (MIX-12518) 2131 S6295 (MIX-I2518, MIX-225;8 & S6965 (MIX-12518. MIX-22518 4 7271-1477:122 (MIX-12518) 7271-1477:117 14803E (M!X-I2518) 219-02-E (MIX-22518/TB) MIX-2251 TB) S6299 (MIX-52518/RB/H) MIX-2251 TB) S7498 (MIX.5251Bm8/H) (MIX-22558/TB) 7271-1477:114 (M525 B/H) (MIX-22518/TS) 390-02-E (MIX-52518/RB/H) APPROVED 3017996 I I I I I I CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. I I I CAT. 5904 Re 5 11111k, MIRcQ Canada U.S.A. 25 Interchange Way 60 Industrial Parkway Vaughan, Ontario L4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 6604113 Web page: http://www.mircom.com Email: mail@mircom.com Specifications Height 2.0 inches (51 mm) Diameter 6.1 inches (155 mm) Installed in B21OLP Base 4.1 inches (104 mm) Installed in B501 Base Shipping Weight Heat: 4.8 oz. (137 g) Photo/Photo with Heat: 5.2 oz. (147 g) Ion: 5.4 oz. (154 g) Operating Temperature Range Ion/Photo: 32°F to 120°F (0°C to 49°C) Photo with Thermal: 32°F to 100°F (0°C to 38°C) Thermal: -4°F to 100°F (-20°C to 38°C) High Temperature: -4°F to 100°F (-20°C to 66°C) Insect Screen Hole Size Photo: 0.016 inch (0.41mm) nominal Ion: 0.035 inch (0.89mm) nominal Thermal Ratings Fixed Temperature Setpoint: 135°F (57°C) Rate of Rise Detection: 15°F/mm. (8.3°C/mm.) High Temperature: 190°F (88°C) Voltage Range 15 - 32 volts DC peak Standby Current Ion/Thermal: 150 uA @ 24 VDC (without communication, LED off) 200 uA @ 24 VDC (one communication every 5 sec. with LED enabled) Photo/Photo with Thermal: UL Listed Velocity Range 250 uA @ 24 VDC (without communication, LED off) Ion: 0- 1200 fpm (0- 5.1 m/sec) 300 uA @ 24 VDC (one communication every 5 sec. Photo/Photo with Thermal: 0 - 4000 fpm (0 - 20 m/sec) with LED enabled) Relative Humidity LED Current (max.) 10% - 93% noncondensing 6.5 mA @ 24 VDC (on) Note: Mounting sensors outside of the specified temperature ranges will cause sensor failures and erratic panel operation. Ordering Information Model Description Intelligent Addressable Analog Sensors MIX-1251B Intelligent Low Profile Ionization Smoke Sensor MIX-2251 B Intelligent Low Profile Photoelectronic Smoke Sensor MIX-2251TB Intelligent Low Profile Photoelectronic Smoke Sensor c/w 135°F Fixed Temp. Thermal Sensor MIX-5251B Intelligent Low Profile Fixed Temp. Thermal Sensor 135°F MIX-5251 RB Intelligent Low Profile Fixed Temp. and Rate of Rise Thermal Sensor 135°F MIX-5251 H Intelligent Low Profile High Temperature Thermal Sensor 190°F Intelligent Analog Bases B21OLP Intelligent Flanged Mounting Base B22481 Intelligent Isolator Base B224RB Intelligent Relay Base* B501 Intelligent Flangeless Mounting Base B501 BH Intelligent Sounder Base B501 BHT Intelligent Temporal Tone Sounder Base Accessories RA400Z Remote LED Annunciator Note: For Canadian models add suffix "A". * When used with the M500X Fault Isolator Module, the number of relay bases between fault isolators is limited to 12. NOT TO BE USED FOR INSTALLATION PURPOSES. I I I I I I I INTELLIGENT ADDRESSABLE MODULES MIX-500 SERIES - Mircom's intelligent module products are designed I to meet a wide range of applications. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull Intelligent Addressable Monitor Module (MIX-M500M) The Intelligent Addressable Monitor Module (MIX- M500M) provides an address for a group of UL/ULC Listed normally open (NO.) initiating devices, such as heat detectors, beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-M500M has an activated red LED. Intelligent Addressable Interface Module (MIX-M502M) The MIX-M502M provides the same features as the MIX-M500M but also allows for the use of multiple, conventional 2-wire smoke detectors in the circuit. This module requires a resettable signal power source. The MIX-M502M internally supervises the seperate power source. The red LED indicates when the module is activated. All two-wire detectors that are monitored must be UL/ULC compatible with the MIX-M502M module. stations, waterflow switches, conventional smoke detectors and more. The modules are addressed with easy-to-use rotary code switches and mount in a standard 4" x 4" x 2 1/8" junction box. L.) U Intelligent Addressable Dual Monitor Module (MIX-M5000M) The Intelligent Addressable Dual Monitor Module'(MIX- M500DM) provides two independent 2-wire initiating device circuits at two separate, consecutive addresses. It is capable of monitoring two separate Class B (Style B) circuits simultaneously, making it ideal forwater flow and tamper switch monitoring. The MIX-500DM has a single activated red LED that is common to either circuit. Intelligent Addressable Mini-Monitor Module (MIX-M501 M) The lntelligentAddressable Mini Monitor Module provides an address for a group of UL/ULC Listed Normally Open (NO.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class B (Style B) initiating circuit. M EA approved APPROVED S5434 S5434 7300-1477:113 427.91-E 3017996 (M(X-M50IM, MIX-500R, (MIX-M500, MIX-M50 1M) MIX-500S S MIX.M502M) 87.01.0 7300-1477:126 (MIX-M500R. MIX.M500S) (MIX-M5000M) 227-03-0 7300-1477:127 (MIX-M5000M) (MIX.M500M) I I I I I I CATALOG NUMBER 5903 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. I o L!! H Intelligent Addressable Supervised Control Module (MIX-M500S) The MIX-M500S Control module provides supervised monitoring of wiring to signal devices that require an external power supply to operate, such as horns, strobes, bells or speaker isolators. Conventional signals will require a 24 VDC power source and speakers will require an audio input. The MIX-M500S does not supervise the power source. A UL/ULC EOL relay such as the A77-716B(A) is required. The red LED will illuminate when the module is activated. The module is capable of Class A (Style Z) or Class B (Style Y) supervision. Intelligent Addressable Relay Module (MIX-M500R) The Intelligent Addressable Relay Module connects to the same loop as the initiating devices and provides two isolated sets of Form-C contacts. The module allows the FX-2000 fire alarm control panel to switch these contacts on command. The MIX- M500R has an activated red LED which follows the state of the relay contacts. Fault Isolator Module (M500X) The M500X Fault Isolator Module is used to protect the system against wire-to-wire short circuits on the analog loop. The modules should be spaced between groups of sensors or modules in a loop to protect the rest of the loop. In the event of a short circuit between any two fault isolator modules, both modules immediately switch to an open circuit condition and isolate any group of sensors between them. The remaining units on the circuit will continue to operate in a normal fashion (must be wired in Class 'A' or Style 6). A maximum load of 25 devices can be connected to an isolator to insure that the isolator powers up correctly. I I I I I I Typical Wiring Diagrams MIX-MSOOM Typical 2-wire initiating circuit configuration, Class B (NFPA Style B) To NEXT DEVICE FROM PANEL OR PREVIOUS DEVICE I I I ANY NUMBER OF UUULC LISTED CONTACT CLOSURE DEVICES MAY BE USED. DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY OR SECURITY DEVICES ON THE SAME MODULE. 4? K EOL RESISTOR INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURERS INSTALLATION INSTRUCTIONS MIX-MSOOM MONITOR MODULE () CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY (+) COMMUNICATION LINE 32 VDC MAX. SHIELDED-TWISTED PAIR IS RECOMMENDED ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED. CAT. 5903 page 2 of 4 111111ii, W—R-C-0—M 0 I I NOT TO BE USED FOR INSTALLATION PURPOSES. I I I I I I I I I I I I I I I I I I I MIX-11111502M Interface two-wire conventional detectors, Class B (NFPA Style B) TO NEXT FROM PANEL OR DEVICE PREVIOUS DEVICE COMMUNICATION LINE INTERFACE 32 VDC MAX. TERMINAL WIRING MUST BE POWER LIMITED. MODULE TWISTED PAIR IS RECOMMENDED DO NOT MIX FIRE ALARM INITIATING. SUPERVISORY. RI DEVICES ON THE SAEX MODULE.d o CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY. r i A2143-ID 00 + 3.9K EOL RESISTOR LISTED BATTERY-BACKUP SWITCHED (INCLUDED) DC POWER SUPPLY. POWER TO THE INTERFACE MODULE K) K/1 I MUST BE EXTERNALLY SWITCHED TO DO NOT LOOP WIRE UNDER TERMINALS. BREAK WIRE RESET THE DETECTORS. AN MIX-M500R RUN TO PROVIDE SUPERVISION OF CONNECTIONS. OPTIONAl I1RANCH CIRCUIT RELAY CONTROL MODULE CAN BE USED TO DETECTORS MUST BE ULC LISTED COMPATIBLE WITH MODULE. TO NEXT INTERFACE MODULE. SWITCH POWER FROM A STANDARD INSTALL DETECTORS PER MANUFACTURERS MODULE SUPERVISES SUPPLY POWER SUPPLY. INSTALLATION INSTRUCTIONS. VOLTAGE AND DETECTOR LOOP. MIX-M500DM Typical 2-wire initiating circuit configuration, Class B (NFPA Style B) TO NEXT FROM PANEL OR PREVIOUS DEVICE DEVICE TWO INITIATING DEVICE CIRCUITS (L & H) EACH POWER LIMITED TO 230uA @ 12VDC MAX. 1:CTMODULESTOLTED tMONOR COMPATIBLE LE fl CONTROL PANELS ONLY J1T o c:1c1 jo ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED. COMMUNICATION LINE 32 VDC MAX. SHIELDED-TWISTED PAIR 0 00 IS RECOMMENDED MONITOR A (TERMINALS 6 & 7) RESPONDS AT ADDRESS SET ON CODE SWITCHES, MONITOR B (TERMINALS 8 & 9) RESPONDS AT NEXT HIGHER ADDRESS. MIX-M500S Typical indicating circuit configuration, Class B (NFPA Style Y) CONNECT MODULES TO LISTED COMPATIBLE COMMUNICATION LINE CONTROL PANELS ONLY 32 VDC MAX. ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED TWISTED PAIR - IS RECOMMENDED 9 - TO NEXT + + FROM PANEL OR DEVICE PREVIOUS DEVICE MIX-MUSOS CONTROL MODULE 24 VDC BRANCH CIRCUIT d 0 DO NOT LOOP WIRE ON TERMINALS 3 & 4. BREAK WIRE RUN TO PROVIDE MODULE POLARITIES ARE 9 SUPERVISION OF CONNECTIONS. SHOWN INALARM ' (.) ". 2 + 47K EOL (-) (-) : + 24 VDC POWER SUPPLY ISOLATED, REGULATED, POWER RESISTOR LIMITED PER NFPA 70. A214300 LISTED FOR FIRE PROTECTION WITH OR EQUAL o c:2 BATTERY BACKUP. (+) ULIULC LISTED EOL RELAY TO NEXT CONTROL MODULE SHOWN ENERGIZED FROM TERMINALS 3 & 4 OR END OF LINE RELAY (EOLR(; 24 VDC COIL A77-716B OF THE LAST CONTROL ONE EOLR REQUIRED PER MODULE ON BRANCH 24 VDC BRANCH CIRCUIT AWL,. iii.cQ! NOT TO BE USED FOR INSTALLATION PURPOSES. 47KEOL ' I RESISTOR II TI L ANY NUMBER OF UUULC LISTED CONTACT CLOSURE DEVICES MAY BE USED. DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY, OR SECURITY DEVICES ON THE SAME INITIATING DEVICE CIRCUIT. INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS CAT, 5903 page 3 of 4 CONTROL MODULE RELAY COMMON 2 NORMALLY CLOSED 2 IlLJ8 1 NORMALLY OPEN 2 IILi7 I 2 RELAY COMMON 1 VLJ6 - 3 NORMALLY CLOSED I rO 5 F4 0000ESS General Specifications Operating Voltage 15-32 VDC Communication Line Loop Impedance 40 max. Temperature Range 32" to 120"F (00 to 49"C) Relative Humidity 10% 1093%: noncondensing Dimensions MIX-M501 M: 1.7"H x 2.7"Wx 050 Others: 4.65H x 4.25"Wx 1.1"D Shipping Weight M5O1M: 1.2 ox (37g) Others: 6.3 ox (196g) Canada U.S.A. 25 Interchange Way 60 Industrial Parkway Vaughan, Ontario L4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com I I CAT. 5903 Reo. 4 MIX-M500R Typical Relay Module Configuration TO N EX DEVICE I N NORMALLY OPEN I PREVIOUS DEVICE I I I 01 ------ t IF ANY WIRING TO TERMINALS 3-9 IS NONPOWER - LIMITED, THE CB500 BARRIER IS REQUIRED. THE CB500 INCLUDES A NONPOWER LIMITED LABEL, WHICH MUST BE PLACED OVER THE POWER LIMITED TERMINAL INFORMATION ON THE NAMEPLATE LABEL. MODULE DOES NOT SUPERVISE CONTROLLED CIRCUITS I I I I I I I I I I Otv?v1UNICA11ON LINE CONNECT MODULES TO LISTED COMPATIBLE 32 VDC Max SHIaDED-TWISTED PAR IS RECOMMENDED CONTROL PANELS ONLY 1\ l ' \ ! I_IFR0M PANEL OR MIX-M500DM Specifications: Standby Current 750 pA max. @ 24 VDC (one communication every 5 sec. with 47k EOL) Alarm Current 970 pA max. (one communication every 5 sec.) 6 mA (with LED latched on) End-of-Line Resistance 47 k (two included) MIX-M500R Specifications: Standby Current 300 pA @ 24 VDC (one communication every 5 sec. with LED enabled) LED Current 5.5 mA (with LED latched on) Relay Contact Ratings 3.0 A @ 30 VDC resistive 0.9 A @ 110 VDC resistive 0.9A @125 VAC resistive 0.5A @125 VAC inductive (PF.35) 0.7 A @ 75 VAC inductive (PF=.35) M500X Specifications: Standby Current 450 pA max Isolation Current 5 mA max Fault Detection Delay 250 ms mm. Fault Detection Threshold 4 Volts Line Restoration Threshold 7 Volts Note: Mounting modules outside of the specified temperature range may cause module failure and erratic panel operation. MIX-M500M, MIX-M500S, MIX-M50IM Specifications: Standby Current 400 pA max @ 24 VDC (one communication every 5 sec. with 47k EOL) 550 pA max © 24 VDC (one communication every 5 sec. with EOL<lk) 5.5 mA (with LED latched on) End-of-Line Resistance 47 k (included) MIX-M502M Specifications: Standby Current 300 pA max @ 24 VDC (one communication every 5 sec. with LED enabled) External Power Supply 18-28 VDC (100 mV ripple max.) End-of-Line Resistance 3.9 k (included) External Supply Standby Current 11.5 mA @ 24 VDC (nominal) External Supply Alarm Current 80 mA @ 24 VDC (nominal) Ordering Information MIX-M500M . Intelligent Addressable Monitor Module MIX-M501 M Intelligent Addressable Mini-Monitor Module MIX-M502M Intelligent Addressable Interface Module MIX-500DM Intelligent Dual Monitor Module MIX-MSOOS Intelligent Addressable Supervised Control Module MIX-M500R Intelligent Addressable Relay Module M500X Fault Isolator Module Note: For Canadian models add suffix "A". NOT TO BE USED FOR INSTALLATION PURPOSES. 11111k, MIRcQr!I by: I I I I I I I I 0000OPER Wheelock I Series RSS and RSSP Strobes and Strobe Plates I FIRE go I WO FIRE Series RSS I Series RSS Series RSSWP RSS Round Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. U Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 1 5130175195cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supplies with the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 1 00m European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Tnmplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock S1312 surface backbox. I ® IiEA APPROVED I S5391 151-92-E 7125-0785:141 7300-0785:154 Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPAJUFC/ANSI compliant. Meets OSHA 29 Part 19 10.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or power sup- plies with built-in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWO wire For Weatherproof Series RSS See Datatsheef S9004 I I I I I I I I I I I I I I I I I I I NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP -Wall Mount RSS - Ceiling Mount 241575W 24MCW 24MCWH 24MCC 24MCCH RSS/RSSP Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd 24 vdc 0.060 0.041 0.063 0.109 0.140 1 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 1 0.300 0.420 0.065 0.105 0.189 0.249 1 0.300 0.420 RSS/RSSP * RMS current ratings are per UL average RMS method. UL max current 24VDC Wall Mountrating is the maximum RMS current within the listed voltage range (16-33v 121575W Models for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, 12 vdc 0.152 see installation instructions. UL max* 0.255 Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE NAC + SYNC CIRCUIT our 0.OUT I IN RSS RSS RSS °MINUS I 0+ L ] AUDIFIL MINUS 2 .42~ -0. IN 2 RSS ROBE NAC 0. our 2 CIRCUIT RETURN Wiring Diagrams 11 ERIES RSS/RSSP APPLIANCE FROM TO NEXT APPLIANCE, SYNC OR EOLR MODULE, POWER PRECEDING APPLIANCE SUPPLY OR FACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #1 StrobeNAE Cir. -IØ + I I RSS F I I RSS I DS 11 M #2 SNAFl.flSSRSS A C I DSM #3' P Strobe NAC Ci DSM Interconnecting wiring shown. Maximum of twenty (20) STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROM APPLIANCE PRECEDING OR EOLR APPLIANCE, SYNC r -I-IJ-tJl MODULE, POWER SUPPLY OR FACP STROBE AUDIBLE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY FROM PRECEDING + + TO NEXT APPLIANCE OR APPLIANCE- FACP - OR EOLR + TO NEXT PROM + - - - PRECEDING I I OREOR sreoRiC SYNC - - - 11 1 1 - - - ROI.R MODUlE,POWER SUPPlY OR FACP I I I I STROBE APPLIANCE For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. Forwiring information on the power supplies refer to Installation Instructions P84515 for PS- 12/24-8CP and P84333 for PS-12124-8MP. Specifications and Ordering Information SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM F + STROBE STROBE A Strobe A NAC 1~1__ lc~~ c Circuit Audibl P EOLR -Audibl SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH PS-12/24-8CP or PS-12/24-8MP Series PS- 12/24-8MP OUTPUTS EOLR F i-I - 4-CLASS A OR AS RSS C 2-CLASS P AS RSS Series PS-I2/24-8M I I I I I I I I I I I I I I I I I I I Model Order Code Wall Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Options Square or Round Agency Approvals - UL - MEA CSFM - FM BFP RSS-24MCW-FR 940 X - X 15130/75/110 X - X - B,D,E,F,G,H,J,N,OR,X Square X X X X X RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X I X X X X RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-121575W-FW 7468 X - X 15(75onAxis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X * RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSS-24MCCHR-FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X RSS-24MCWH-FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP2475WFR** 9013 X - X 180@ 77-F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSWP2475WFW** 3034 X - X 180@ 77-F X X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X * RSSP-121575W-FR 7798 X - X 15 (75 on Axis) - X X - D,E,Z Square X X X X X RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP-241575W-FR 7793 X - X 1 15 (75 on Axis) - - X - D,E,Z Square X X X X X RSSP-24MCWH-FR 9482 X I I X 1 135/185 1 X I I X I I B,D,E,F,G,H,J,N,O,R,X Square X X X * * All models sync with Wheelock SM, DSM or PS-12/24-8CP or PS-12/24-8MP. *PENDING # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. For Weatherproof Series RSS Strobe specifications see data sheet S9004. **Refer to data sheet S7000 for mounting options. 00 COOPER Wheelock 273 Branchport Avenue Long Branch, NJ 07740 I Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheetock.com I WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S0410 RSS/RSSP 06/06 if Member - Rrcnhtecfs ana The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 151301751110cd or 135/185cd for wall mount and 15/30175195cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or the Wheelock PS-24- 8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Tnmplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. C51- COOPER Wheelock Series AS Audible Strobe Appliances and Series AH Auddibles I I rL.IRE :1EI I V Ui SERIES AS SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/751110cd, or the high intensity MCWH strobe with field selectable 1351185cd. Ceiling mount models incorporate Wheelock's patented MCC multi-candela ceiling strobe with field selectable intensities of 15130/75195cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. I When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-24-8MC Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporal (code 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a I distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive. At the same time the strobes will be synchronized. This provides the ability to I comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. I Features Approvals include: UL Standard 1971, UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP). See approvals by model in Specifications and Ordering Information ADA/NFPA/UFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/11ocd or 135/185cd (Multi- Candela models) or 1575cd (single candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-Wire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL Regulated Voltage Range" using filtered DC or unfiltered F\NR input voltage The strobes can be synchronized using Wheelock's sync modules or power supplies with built in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18AWG wires For Weatherproof Series AS, See Dafasheet S9004 I I <g> IViEA APPROVED E5946 151.92.E 7125.0785:131 I I I I I I I I I I High (99) 12 vdc 0.163 0.260 UL max* 0.192 0.320 dBA Med (95) 12 vdc 0.076 0.195 UL max" 0.108 0.275 dBA Low (90) 12 vdc 0.039 0.175 UL max" 0.058 0.265 dBA 24 VDC Models High (99) 24 vdc dBA UL max* Med (95) 24 vdc dBA UL max* Low (90) 24 vdc dBA UL max* 12 VDC Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd llocd 135cd 185cd 15cd 30cd 75cd 95cd 11 5c 177cd 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 Audible Wall Mount Audible Strobe AH-12 I AS-121575W Table 4: Average Current* (AMPS) For Series ASWP# Voltage High dBA Setting (99) dBA Medium dBA Setting (95) dBA Low dBA Setting (90) dBA 24.0 VDC 0.128 0.105 0.098 UL Max* 0.168 0.155 0.150 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR I APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. I General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range'. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. I .Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the I terminology "Listed Voltage Range". I I I I Table 3: Average RMS Current I Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models Table 1: Ratings Per UL 1971 Model Number Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (Cd) AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0-33.0 15 (75 on Axis) AS-121575W 12 8.0-17.5 15 (75 on Axis) AS-24MCC 24 16.0 -33.0 15/30/75/95 AS-24MCWH 24 16.0 -33.0 135/185 ASWP-2475W 24 16.0-33.0 75 @ -31°F Table 2: dBA Ratings for 12 VDC and 24 VDC Series AS/AH 12 and 24 VDC Audible Reverberant Anechoic Description Volume dBA Per UL 464 dBA @10 ft. @10 ft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Medium 84 95 Code 3 Horn Low 79 90 Wring Diagrams ' SERIES AS APPLIANCES NON-SYNCHRONIZED FROM TO NEXT APPLIANCE - OR EOLR OR FACP PRECEDING APPLIANCE SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12124-8CP and PS-12/24-8MP F - 1-4 E 4-CLASS 1E][III}OUTPUTS A B OR C 2-CLASS P As SS Series PS-I2/24-8CP or PS.12/24.8MP A SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE SOAL SYNC MONULS Øzvno Øavnc I I SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODULE SIN- GLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEATURE SM F -0+ STROBE robe - STROBE A NAC EOLR Audible -Audlbl NAC Cli'cult SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES ,.,,. DSM #1 DSM Interconnecting wiring shown. Maximum of twenty (20) For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-8MC. I I I I I I I I I I Specifications and Ordering Information Model Number Order Code Strobe Candela Non Sync Sync w/SM, DSM or 24 VDC 12 VDC Wall Mount Mount Ceiling Agency Mounting Options Approvals FM BFP \S-24MCW-FR 9024 15/30/75/110 X X X - X - A,BD,E,F,G,HJ,N,O,R,X X X X X X \S-24MCW-FW 9025 1 15/30/75/110 X X X - X - ABD,E,F.G,H,J,N,O,R,X X X X X X \S-24MCWH-FR 3468 135/185 X X X - X - ABD,EFG,HJ,N,O,R,X X X X X * \S-24MCWH-FW 3469 135/185 X X X - X - A,BD,E,F,G,HJ,N,O,R,X X X X X * AS-241575W-FR 7405 15(75onAxis) X X X - X - A,BD,E,FG,H,JN,OR,X X X X X X \S-121575W-FR 7410 15(75onAxis) X X - X X - A,B,D,E,F,G,H,J,N,O,R,X X X X X X S-24MCC-FR 3161 15/30/75/95 X X X - - X A,B,D,E,F,G,H,J,N,O,R,X X X X X * S-24MCC-FW 3162 15/30/75/95 X X X - - X A,BD,EFG,H,J,N,O,R,X X X X X * S-24MCCH-FW 3467 115/177 X X X - - X A,BDE,F,G,H,J,NO,R,X X X X X * SWP2475WFR** 9012 75 @ -315F X X X - X - I (see Data Sheet S9004) X X X X X H-24-R 7892 - X X X - X X AB,DE,F,GHJ,NO,R,X X X X X X H-24-W 7893 - X X X - X X AB,DEF,GHJNO,R,X X X X X X H-12-R 7891 - X X - X X X A,BD,EFGH,J,N,O,R,X X X X X X H-12-W 7894 - X X - X X X ABD,E,FG,HJ,N,OR,X X X X X X H24WPR** 7416 - X X X - X X K X X X X 1-112WPR** 7415 - X X - X X X K X X X X **For Weatherproof Series AS/AH specifications see data sheet S9004. *PENDING ***Refer to Data Sheet S7000 for Mounting Options. Note: Models are available in either Red or White. Contact Customer Service for Order Code and Delivery. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. I I I I I I I I I Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The SeriesASAudible be listed for UL Standard 1971 (Emergency Devices forthe Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock PS-24-8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash- rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. I I I I I I I I I I 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com IMember -. 3 YEAR WARRANTY Made in USA S8100 AS/AH 06/06 I I I I 000 U COOPER Wheelock I I I I I Description: Series NS Horn Strobes and Series NH Horns Series NS Series NH Features: The Series NS Horn Strobe Appliances are designed for indoor, wall and ceiling mount applications. The Series NH Horn and the horn portion of the Series NS include a selectable continuous horn tone or temporal pattern (Code 3) with selectable dBA settings of 90 or 95 dBA. Strobe options include 1575cd or the Wheelock patented Multi-Candela strobe with field selectable candela settings of 15/30175/110cd for wall mount and 15/30175195cd and 115/177cd for ceiling mount. These versatile Horn Strobe Appliances can be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supply with the Wheelock patented Sync Protocol. Additionally, the audible may be silenced while maintaining strobe activation. All models of the Series NS and NH are designed for maximum performance, reliability and cost-effectiveness while meeting or exceeding the latest requirements of NFPA 72/ANSI 117. 1/UFC and UL Standards 1971 and 464 as well as meeting ADA requirements concerning photosensitive epilepsy. The Wheelock patented 2-Wire Series NS Horn Strobes and Series NH Horns offer more features with lower current draw than competitors. I I <*> MEA APPROVED E5946 151-92-E 7125-0785:142 S5391 I I I I I I I I Approvals include: UL Standard 1971, UL Standard 464, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP). See approvals by model number in Specifications and Ordering Information ADA/NFPA/UFC/ANSI compliant Complies with OSHA 29, Part 1910.165 Wall mount model Field Selectable Candela Setting 15/30/75/110cd (24 VDC Multi-Candela models) or. 1575cd in 12 or 24 VDC Ceiling mount model Field Selectable Candela Setting 15130/75/95cd and 115/177cd (24 VDC Multi-Candela models) Selectable Continuous Horn or Temporal (Code 3) 2 Selectable dBA settings of 90 and 95 dBA in both tones Patented Universal Mounting Plate 12 and 24 VDC models with UL "Regulated Voltage" using filtered DC or unfiltered VRMS input voltage Wall and Ceiling Mount Ceiling models with same look as Wheelock round ceiling strobes and speakers NH horn is selectable 12 or 24 VDC in 1 appliance The strobes can be synchronized using the Wheelock sync modules or power supplies with built in Sync Protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires I ,' NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Genera! Notes: Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range'. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL Standard 1971 Model Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela (CD) NS-24MCW 24 16.0-33.0 15/30/75/110 NS-241575W 24 16.0-33.0 15(75onAxis) NS-121575W 12 8.0-17.5 15 (75 on Axis) NS-24MCC 24 16.0 -33.0 15/30/75/95 NS-24MCCH 24 16.0-33.0 j 115/177 Table 2: dBA Ratings for Series NS/NH Horn Reverberant dBA Anechoic dBA @ 1 Oft per UL 464 @10ft Description Volume 12 24 12 24 VDC VDC VDC VDC Continuous High 83 87 89 95 Low 76 81 84 90 Horn Code 3 High 79 82 89 95 Low 72 76 84 90 Horn Table 3: UL Max Current* Series NS/NH Audible Wall Mount Strobe Models Ceiling Mount Strobe Models NH-12/24 NS-241575W 24 VDC NS-24MCW NS-24MCC NS-24MCCH @24VDC 15175cd I5cdI30cd 75cd I llOcd I5cd 30cd175cd1 95cd 115cdI77cd High (95) dBA[24VDC 0.044 0.104 0.074i0.107l0.184 0.244 0.082 0.124 0.209 0.275 0.350 0.477 Low (90) dBA L24VDC 0.018 0.096 0.066 0.101 0.177 0.232 0.071 0.114 0.201 0.261 0.306 0.429 Series NS/NH I2VDC Audible Wall Mount * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range. (1 6-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. NH-12/24 Aud/Strobe @I2V NS-121575W High (89) dBA 112 VDC 0.021 0.220 Low (84) dBA [I2VDC 0.012 0.210 Wiring Diagrams" NS/NH APPLIANCE FROM + TO NEXT PRECEDING - APPLIANCE APPLIANCE, SMIDS 7F- OR EOLR PS-12/24-8MP PS-12/24-8CP OR FACP SIGNAL NS AND NH APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILENCE FEATURE SM F STROBE 0 - STROBE Strobe P Ll EOLR Audible -Audibi NAC Circuit NOTE: NS/NH must be set on Code 3 horn tone to achieve synchronized temporal (Code 3) tone. Refer to Installation instruction (P83983, P83600 respectively). 11 For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84662 for PS-24-8MC. NS AND NH APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE DUAL SYNC MODULE 08 YN C 05-NO - OUT, - Q MINUSI F +5uOILE K- DIM A C IRCIIT OUT - AUDIBLE P APPLIANCE APPLIANCE I I -.NU- 6: , ( N AL CCUIT RETURN SPECIFICATION & ORDERING INFORMATION Model Number Order Code Strobe Candela Sync wl SM, DSM or PS-24-8MC 24 VDC 12 VDC Mounting Options# Agency Approvals - UL FMEA - - NS-24MCW-FR 9404 15/30/75/110 X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS-24MCW-FW 9405 15/30/75/110 X X - B,D,EF,G,H,J,N,OR,X X X X X X NS-241575W-FR 7806 15(75onAxis) X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS-241575W-FW 7811 15(75onAxis) X X - B,DE,F,G,H,J,N,O,R,X X X X X X NS-121575W-FR 7816 15(75onAxis) X - X B,D,E,F,G,H,JN,OR,X X X X X X NS-121575W-FW 7818 15(75onAxis) X - X B,D,E,F,G,H,J,NOR,X X X X X X NH-12/24-R 7449 - X X X B,D,E,F,G,H,JNOR,X X X X X X NH-12/24-W 7500 - X X X B,D,E,F,G,H,J,N,O,R,X X X X X X NS-24MCC-FR 3754 15/30/75/95 X X - E X * X X * NS-24MCC-FW 3753 15/30/75/95 X X - E X * X X * NS-24MCCH-FR 3756 115/177 X X - E X * X X * NS-24MCCH-FW 3755 115/177 X X - E X * X X * NH-12/24R-R 3752 - X - X B,DE,F,G,H,J,N,O,R,X X * X X * NN-12/24R-W 3751 - X - X B,D,E,F,G,H,J,N,O,R,X X * X X * NS and NH Ceiling Mount Appliances will be available July 2006. *pending Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS The audible/visual notification appliances shall be Wheelock Series NS Horn Strobe appliances and Series NH Horn appliances or approved equals. The Series NS appliances shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing- Impaired for Indoor Fire Protection Service). The Series NH Horn shall be UL Listed under Standard 464 (Fire Protective Signaling). The horn strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of two (2) field selectable settings for dBA levels (90 and 95 dBA) and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series NS shall be of low current design. Where wall mount, Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/110 candela. Where ceiling mount, Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/95 candela or 115/177 candela. The selector switch for selecting the candela setting shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with the Wheelock SM, DSM Sync Modules or the Wheelock PS-24- 8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobes shall revert to a non-synchronized flash- rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series NS Horn Strobes and NH horn shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single- gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Tnmplate) shall be provided. All notification appliances shall be backward compatible. I I I I LT I I I I LI I I I I W"--•i 273 Branchport Avenue Long Branch, NJ 07740 I Phone: (800) 631-2148 Fax: (732) 222-2588 www.cooperwheelock.com I WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S2100 NS/NH 10/06 00 COOPER Wheelock Series SM and DSM Sync Modules Series SM or DSM Description The Wheelock Series SM and DSM Sync Modules are utilized with the Series AS/AH, Series NS/NS4/NH, Series RSS, Series RSSP, Series SLM and selected strobe applications with other Wheelock combination appliances. When used with Series AS Audible Strobes and/or Series NS Horn Strobes, the SM and DSM Sync Modules provide independent operation of synchronized temporal pattern (code 3) horn and synchronized strobe flash, as well as the ability to silence the horn while maintaining the strobe flash. while using only a single pair of wires. The sync modules are available in two versions; the SM-1 2/24 for control of a Class B NAC circuit; and a dual output version, the DSM-1 2/24 for control of either a Class A or two (2) Class B NAC circuits. Features Approvals include: UL Standard 1971, ULC, New York City (MEA), California State Fire Marshal (CSFM) and Chicago (BFP) Uniquely designed to accept an independent strobe and audible input from the FACP and convert to a single output that connects to Wheelock's Series AS or Series NS family of audible strobes Series SM and DSM Sync Modules can also be used to synchronize Wheelock's Series RSS, RSSP and SLM Sync Strobes 3 ampere per circuit current handling at 12 or 24 VDC Low operating current draw Compatible with all standard fire alarm control panels Meets the NFPA-72 requirement for Temporal Pattern when used with the Series AS/AH and/or Series NS/NS4/NH 3 year warranty POWERPATHCP AS/AH, NS, HS4/HS FIRE ALARM POWERPATHMP _____ NH, RSS, RSSP, CONTROL PANEL OR SM OR DSM E w/STB, ET w/STB, (FACP) OTHER POWER CH w/STB BOOSTERS APPLIANCES SM or DSM Connection Diagram with Power Booster ®1 <g> MEA " APPROVED E5946 151-92E 7300-0785:132 Table 1: Sync Module (SM) Current Requirements (AMPS) TabIe2: Sync Module (DSM) Current Requirements (AMPS) UL Voltage ULC Voltage Rated Average Current Rated Peak Current Rated Inrush Current UL Voltage ULC Voltage Rated Average Current Rated Peak Current Rated Inrush Current Ini Audible ml Audible Ini Audible ln1!In2 Audible ln1/1n2 Audible ln1lln2 Audible 8.0 VDC 10.5 VDC 0.017 0.004 0.055 0.004 0.140 0.016 8.0 VDC 10.5 VDC 0.019 0.004 0.055 0.004 0.150 0.016 12.0 VDC 12.0 VDC 0.017 0.004 0.060 0.004 0.160 0.019 12.0 VDC 12.0 VDC 0.020 0.004 0.064 0.004 0.170 0.019 24.0 VDC 24.0 VDC 0.028 0.008 0.070 0.008 0.320 0.030 24.0 VDC 24.0 VDC 0.035 0.008 0.080 0.008 0.342 0.030 33.0 VDC 33.0 VDC 1 0.038 0.010 j 0.080 0.010 0.440 0.040 33.0 VDC 33.0 VDC 0.045 0.010 0.090 0.010 0.470 0.040 8.O VRMS 8.0 VRMS 0.026 0.006 0.085 0.008 0.210 0.016 8.0 VRMS 8.0 VRMS 0.028 0.005 0.107 1 0.008 0.210 0.016 12.0 VRMS 12.0 VRMS 0.028 0.006 0.090 0.009 0.225 0.019 12.0 VRMS 12.0 VRMS 0.030 0.006 0.103 0.009 0.240 0.019 24.0 VRMS 24.0 VRMS 0.040 0.010 0.120 0.015 0.446 0.033 24.0 VRMS 24.0 VRMS 0.048 0.010 0.145 0.015 0.480 0.033 33.0 VRMS 31.0 VRMS 0.055 0.012 0.150 0.022 0.645 0.056 33.0 VRMS 31.0 VRMS 0.062 0.012 0.175 0.022 0.685 0.056 NOTE: All CAUTIONS and WARNINGS are Identified by the symbol A. All warnings are printed In bold capital letters. I ,WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE,.AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. I WARNING: MAKE SURE THAT THE TOTAL CURRENT REQUIRED BY ALL APPLIANCES THAT ARE CONNECTED TO A SM OR DSM DOES NOT EXCEED 3.OA OR EXCEED THE RATING OF THE FIRE ALARM CONTROL PANEL'S PRIMARY AND SECONDARY POWER SOURCES AND NAC CIRCUITS. OVERLOADING THESE SOURCES COULD RESULT IN LOSS OF POWER AND FAILURE TO ALERT OCCUPANTS DURING AN I EMERGENCY, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. When calculating the total current, use Tables 1 & 2 to determine the highest value of 'Rated Average Current" for the SM or DSM (across the listed volt- age range), then add this value to the total current for any other appliances powered by the same source and include any required safety factors. Refer to Instruction Sheet for addlional information. I WARNING: MAKE SURE THAT ALL FUSES USED ON NAC CIRCUITS ARE RATED TO HANDLE THE MAXIMUM INRUSH OR PEAK CURRENT FROM ALL APPLIANCES ON THOSE CIRCUITS. FAILURE TO DO THIS MAY RESULT IN LOSS OF POWER TO THE NAC CIRCUIT AND THE FAILURE OF ALL APPLIANCES ON THAT CIRCUIT TO OPERATE, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Table 3: Current Consumption of the SM and DSM Modules Outpurt Circuit Description of SM/DSM Module SM Module DSM Module Ref. Fig. Class "B" with Audible Silence (single circuit) Y 1 Class "B" with No Audible Silence (single circuit) Y 2 Class "B" with Audible Silence (dual circuit) Y 3 Class "B" with No Audible Silence (dual circuit) Y 4 Class "A" with Audible Silence (single circuit) Y 5 Class "A" with No Audible Silence (single circuit) Y 6 Note: SM Sync Modules are rated for 3.0 amperes at 12/24 VDC; DSM Dual Sync Modules are rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules is twenty (20). A CAUTION: Use SM or DSM Sync Modules only on NAC circuits with continuously applied voltage. Do not use SM or DSM Sync Modules on coded or interrupted NAC circuits in which the applied voltage is cycled on and off. ACAUTION:Power Boosters may be used in conjunction with the SM or DSM Sync Modules only in the order shown below. Only one SM or DSM Sync Module shall be allowed on a NAC circuit. Do not connect Power Booster to the NAC circuit after the one SM or DSM Sync Module. Exception: The Wheelock PS-24-8MC Power Booster can be connected either before or after the SM or DSM Sync Module. Refer to Power Booster instruction manual for proper application and installation. I I I I I I I I I I ,, AWARNING: THESE APPLIANCES WERE TESTED TO THE OPERATING VOLTAGE LIMITS OF 8-33 VOLTS USING FILTERED DC OR UNFILTERED I FULL-WAVE RECTIFIED (FWR). DO NOT APPLY 80% AND 110% OF THESE VOLTAGE VALUES FOR SYSTEM OPERATION. THE APPLICATION OF IMPROPER VOLTAGE MAY RESULT IN DEGRADED OPERATION OR DAMAGE TO THESE PRODUCTS, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Ak WARNING: CONTACT WHEELOCK FOR "INSTALLATION INSTRUCTIONS" (P83123-SM & P83177-OSM) AND "GENERAL INFORMATION" SHEET ON THESE PRODUCTS. These documents do undergo periodic changes. It is Important that you have current information on these products. These materials contain important information that should be read prior to specifying or installing these products including: TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NAC CIRCUITS TO HANDLE MAXIMUM INRUSH OR PEAK CURRENTS FROM ALLAPPLIANCES ON THOSE NAC CIRCUITS. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED IN PUT VOLTAGE RANGE. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON NAC CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBE ON CODED OR INTERRUPTED NAC CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBE MAY NOT FLASH. Architects and Enqineers Specifications The sync modules shall be Wheelock Series SM or DSM Sync Modules. Series SM or DSM Sync Modules shall be the master control- lers for Wheelock Series AS/AH, NS/NS4/NH, RSS, RSSP and appliances where a synchronized audible/visual audible or visual only appliance is specified. All modules shall be UL listed under Standard 464. Series SM and DSM modules shall be designed to interface with Series AS Audible Strobe Appliances and NS Horn Strobe Appliances to produce a syn- chronized temporal (Code 3) horn as well as synchronized strobe flash on a two-wire alarm circuit. Other synchronized products are the Wheelock Series RSS, RSSP, SLM visual only appliances and Series AH and NH Horn Appliances. SM Sync Module shall incorporate two input NAC circuits for power connection from the Fire Alarm Control Panel; one for the strobe NAC circuit and one for the audible NAC circuit. DSM modules shall provide an additional strobe circuit input/output for control of either two Class "B" NAC circuits or a single Class "A" NAC circuit. Upon activation of the audible silence function at the Fire Alarm Control Panel, the audible signal component of Series AS Audible Strobe and/or the Series NS Horn Stobe may be silenced while maintaining strobe activation. Series SM or DSM module shall be designed and available in two versions; the SM-12/24 for control of a single Class B NAC circuit and a dual output version, the DSM-1 2/24 for control of either Class A two (2) Class B NAC circuits. The DSM dual circuit version shall provide the additional capability of "daisy-chaining", that is, the ability to interconnect multiple DSM's for synchronous horn and strobe operation on multiple NAC circuits. Interconnection capability shall be for a maximum of 40 NAC circuits. All modules shall operate on either 12 or 24 VDC. Rated average current requirement for the SM 12/24 shall be .017 amperes @ 12 VDC and .028 amperes @ 24 VDC. The DSM 12/24 shall be .020 amperes @ 12 VDC and .035 amperes @ 24 VDC. A single circuit SM Sync Module shall be capable of handing a 3 ampere load at 12 or 24 VDC and the dual circuit DSM Sync Module shall be capable of handling a load of 3 amperes per NAC circuit at 12 or 24 VDC. All versions shall be polarized for DC supeMsior and shall incorporate screw terminals for in/out field wiring of #18 to #12 AWG wire size. The SM and DSM Sync modules shall mount to a 4-11/16" x 2-1/8" deep backbox. I I NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. I I I I I I I I I I C00 00 I PER Wheelock 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 I Fax: (732) 222-2588 www.cooperwheelock.com I r'zr WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S3000 SM/DSM 06/06 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1477:111 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Mircom Technologies Ltd, 25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888)660-4655 FAX (888) 660-4113 DESIGN: Models FX-2000 and FX-2000H analog fire alarm control units. Non-coded, automatic, manual, local, auxiliary, remote station, central station, waterfiow and sprinkler supervisory service. Refer to the listee's data sheet for detailed product description and operational considerations. System components: FX-2003-6, FX-2003-12, FX-2009-12V FX-2017-12, FX-2009-1 2, FX-2003-6H FX-2003-1 2H *Fx..2001..6K *Fx..2001..6KU MD-596 MD-597 MD-519 MD-616, IPS-2424 DM-1008A, SGM-1004A, RM-1008A PR-100 DACT-100, IJDACT-100, *UDACT..300A QX-5000 ECX-001 2 BBX-1024, -1072, BB-5008,-5014 RTI-1 RAX-1048, RAX-1048TZ ALC-H16, -198S, -396S, -127H, -254H Main Chassis/Power Supply Main Chassis/Power Supply Main Chassis/Power Supply One Analog Loop Fire Alarm Kit Fire Alarm Module Display Module Annunciator Assembly Bypass Display Zone Adder Module Polarity Reversal/City Tie Module Dialer Modules Voice Adder Module Expander Chassis Enclosure Remote Trouble Indicator Annunciator Module Loop Adder Module H H I I INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally compatible initiating and indicating devices. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA72, 1999 Edition. Refer to listee's Installation Instructions Manual for details. I NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev. 08-22-2006 jew I . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or % recommendation of the item listed. This listing should not be used to verifycorrect operational requirements or installation V criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. I Date Issued: AUGUST 22, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy I . Program Manager I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-1477:107 Page 1 of 1 CATEGORY: Annunciators LISTEE: Mircom Technologies Ltd, *25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 DESIGN: Model RA-1 000 remote multiplex annunciator panel. The main annunciator module provides indication for 32 zones. Each adder annunciator module provides indication for 48 additional zones. Unit includes main annunciator chassis RAM-1 032 and adder annunciator chassis RAX-i 048. Model RAX-LCD Liquid Crystal Annunicator, Model MGD-32 Master Graphic Driver chassis, Model MGDS-16/16 Main Display Annunicator Chassis and Model AGD-048 Adder graphic Driver chassis. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 20-29 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as annunciator panel for use with listee's separately listed compatible fire alarm control unit. Model RA-1 000 is suitable for use with listed compatible Model FA-1 000 (CSFM Listing No. 7165-1477:106) and FX-2000 (CSFM Listing No. (7165-1477:111) fire alarm control units. Model RAX-LCD is suitable for use with listed compatible Model FX-2000 fire alarm control unit (CSFM Listing No. (7165-1477:111). *Rev. 11-04-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1477:128 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Mircom Technologies Ltd, 25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 DESIGN: Models MS-701U, -703U, 704U, -710U, -713U, -714U, 701ADU, -710ADU, *..702u *..702ADu *-701 UP, *..710up *..703u(C) *..704u(c) *..713u(C) *..714u(C) *..705u *..715u *706U(C), *716U(C), *707U(C) and *..717U(C) fire alarm boxes. These devices are manually actuated, single or dual action non-coded, fire alarm boxes for indoor use only. Units are to be mounted on standard outlet boxes or listee's Model BB- 700 backbox *for indoor use only and *BB..700wP backbox for indoor and outdoor use. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC, 1A, 125 VAC, 1A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev 12-02-2005 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager I I I U I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0785:132 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Models SM-12/24, SMX-12/24, DSM-12/24 and DSMX-12/24 Synchronized Control Modules. Models SM-12/24 and DSM-12124 may be followed by -R, -w, -x or -S. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 10.5 - 31 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling appliances accessory for use with separately listed synchronized strobe lights. For indoor use only. Rev. 06-13-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager I I ,1 I I LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: APPROVAL: XLF: Misc. Devices/Control Unit Accessories Mircom Technologies Ltd, *25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 Models MIX-M501M Monitor Module, and Models MIX-500R, MIX-500S, MIX-M500CH, and MIX-M502M Control Modules. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, electrical rating and UL label. Listed as accessories for use with separately listed compatible fire alarm control units. 7300-1209:104 I I I I I I I I I I I MCALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1477:113 Page 1 of 1 I I I I I I I I Rev.11-04-2003 '.. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results 1. and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No 7272-1477:117 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Mircom Technologies Ltd, *25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888)660-4113 DESIGN Models MIX-2251, MIX-225113, MIX-2251T, MIX-2251TB, MIX-2251TMB photoelectric smoke detector. Model MIX-2251T employs an integral supplemental heat sensor. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors when used in conjunction with listee's listed separately listed compatible fire alarm control units and bases. Each model is suitable for open areas with air velocity between 0-4000 fpm. Models MIX-2251,-2251B, -2251TB and -2251TMB are also suitable for installation inside ducts with a maximum air velocity of 4000 fpm. 7272-1209:160 *Rev. 11-04-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 22, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager I I I I I I I I I I I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION• OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE I LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: *Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for I the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W I audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. I Models AS-2415C, -2430C, -2475C and -241 OOC audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. I Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. I Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling I for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed I by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. I Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR I Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd I MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. I *Rev. 06-13-06 I Listing No. 7125-0785:131 Page 2 of 2 I MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used I in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-1 2WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's I Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. I NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. I *Rev. 06-13-06 ....• This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ;..4.. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 13, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:142 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 DESIGN: Models NH-12/24, NH-12/24R, and *ZNH horns and Models NS-1215W, NS-121575W, NS-2415W, NS-241575W, NS-2430W, NS-2475W and NS-24110W; NS4-1215W, NS4- 121575W, NS4-241 5W, NS4-241 575W, NS4-2430W, NS4-2475W and NS4-241 low, NS-24MCW, NS4-24MCW, NS-24MCC, NS-24MCCH, *ZNSMCW *ZNSMCC *ZNS MCWH and *ZNS..MCCH horn strobes. Model number may be followed by any two- alpha/numeric characters indicating lens, lettering and color, Units are synchronized or non-synchronized strobes. Models NH-12/24R, NS-24MCC, NS-24MCCH, *ZNS..MCC and *ZNS..MCCH are ceiling mount only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical-Strobe Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Candela: 15=15cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) NS-24MCW, NS4-24MCW, *ZNS..MCW: Selectable 15cd, 30cd, 75cd, 110cd *NS..24MCC *ZNSMCC: Selectable 15cd, 30cd, 75cd, 95cd *NS..24MCCH *ZNSMCCH: Selectable 115cd, 177cd *ZNS..MCWH: Selectable 135cd, 185cd Flash rate: 60 Flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. *All units are for wall mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed electrically compatible fire alarm control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only except for model NH-1 2/24 horn. All synchronization strobes shall be used with Models SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132). Refer to manufacturer's installation manual for details. NOTE: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. *Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: DECEMBER 13, 2006 Listing Expires June 30, 2007 Authorized By: KEN VOLLEN WElDER, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Brian Lampe (800) 631-2148 ext. 6389 Fax (732) 222-5607 I DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 I 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 I 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- I 24MCCHR, RSSP-24MCCH, *ZRS..MCC *ZRSMCW *ZRSMCCH and *ZRS.MCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 = 1 6-33VDC/FWR Candela 15=5cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRS.MCW: Selectable 15cd, 30cd, 75cd I or 11 0cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRSMCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRSMCWH: I Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRSMCCH: Selectable 115cd, 177cd I Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with I suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: I Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. I 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. *Rev. 12-13-2006 jw 11 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: DECEMBER 13, 2006 Listing Expires June 30, 2007 Authorized By: KEN VOLLENWEIDER, Senior Deputy Program Manager