Loading...
HomeMy WebLinkAbout1340 POINSETTIA LN; ; FA070092; Permit5/27/2021 FA070092 Permit Data S City of Carlsbad Fire Alarm Permit 1340 POINSETTIA Job Address: LN Permit Type: FALARM Parcel No: 2150704700 Lot #: 0 Permit No: FA070092 Status: ISSUED Applied 12/27/2007 Approved: 12/27/2007 Reference No.: Issued: 12/27/2007 PC #: Inspector: Project Title NORTH COAST CALVARY CHAPEL TWO FIRE ALARM INSECTIONS @ $65/EA Applicant: EMCOM ELECTRONIC SYSTEMS, INC. SUITE H 256 WITHERSPOON WY EL CAJON, CA 619-667-1200 Owner: Fees ($) Add'I Fees ($) Total ($) S Balance ($) 130 0 130 0 1/1 North Coas Calvary Chapel - Multi-Purpose Building Alarm System Review Comments. Page 2 Review Comments / North Coas Calvary Chapel - Multi-Purpose Building Alarm System, 1340 Poinsettia, Carlsbad, California A manual pull station should be added at the double exit doors to the exterior of the upper right hand corner of the gymnasium. (Field Verify) No scale or north arrow on floor plan sheets. Site plan has building labeled "Auditorium", verify this is the same building. 15 cd strobe at end of corridor near office 202 should be relocated to the opposite wall to the right for better visibility throughout the corridor. MIX-3 100 alarm current is shown as 4 mA in the catalog data sheets, while the calculations show only 0.34 mA. Results in minor increase in alarm current, and total current. No revision required. MIX- 1O1P alarm current is shown as 4 mA in the catalog data sheets, while the calculations show 0.6 mA. Results in minor increase in alarm current, and total current. No revision required. EMCOM ELECTRONIC SYSTEMS, INC. CALIC.820216 SEC. L1C ACID 3838 256 WITHERSPOON WAY, SUITE H • EL CAJON, CA 92020 • PH. (619) 667-1200 • FAX (619) 667-1222 I I I Fire Alarm System Equipment Submittal I I I for I I North Coast Calvry Chapel I Multi Purpose Building 1340 Poinsettia I Carlsbad, CA APPROVEASLJBMITTED I CARLSBA5F1bEPARTMENT iliesc plaits ha c No, revswctl t'i llpiin1 otitipltaitce Iwillt theei lirelit ap 111thl soiLs alld standards iii liitL'C itt tlti no s,liititt. 1ltciVsi1Ct r V.01111,K101 May titilirt this is so" it sltpptrt ol nit :ippltcittitit 'i t htnldttie nt vnttt 't ith the tprsss titrts-rstttirlt;lg that this rits'tsw ii itt o to rel cvi' the owner oi con tractor or t kit j,tt,fesstitnal citt!lilccr or architect for sole icspisitsihilily for full coinpliattce with said codes and standards. including the building ctie or for any responsihibty For deticieneics. errors. omissions or negligence in these plaits whether or not noted in this review. Dale: eviewer: cl RECOMMEND APPROVAL RECOMMEND APPROVAL. AS NOTED INTELLIGENT FIRE ALARM CONTROL PANELS FX-350 SERIES I The FX-350 Series Intelligent Fire Alarm Control Panels are single loop addressable panels with support for up to 60 or 126 addressable points. The FX-350 Series panels are equipped with a two line by 20 character backlit LCD display, numerical keypad and an integrated UDACT/ Digital Communicator. The FX-350 Series family also includes remote LED and LCD annunciators.' The FX-350 Series panels are ideal for both new and retrofit applications. Designed for small to medium commercial, institutional and industrial occupancies, these panels are powerful enough to meet today's in demands. The FX-350 Series panels are configurable by the keypad for onsite programming or by a PC for both onsite and remote programming. Easy to install and simple to operate and configure, the FX-350 Series panels enable the installer to configure the system to meet their specific requirements. The F-350 Series panels are equipped with a 5.5 Amp power supply, auxiliary resettable smoke power supply (300mA max.), an interface for a Remote Trouble Indicator (RTI- 1) and an RS-485 interface for remote LCD and LED annunciators. All FX-350 Series panels come complete with a red door, black enclosure, durable CAT-30 lock and key and space to mount up to 12 AH batteries. Optional trim rings are available for semi-flush mounting. Features Single Addressable SLC Loop that supports 60 or 126 addressable points Points can be any combination of Addressable Sensors or Modules Supports Ionization Sensors, Photoelectric Sensors, Variable Heat Sensors and Multi—Sensor (Heat/Photo) Equipped with a 2 line by 20 character backlit LCD display, numerical keypad and an integrated UDACT/ Digital Communicator Digital Communicator can be configured for DACT or UDACT mode of operation Configurable via the front panel, PC Configurator, or remote dial up through the built-in modem Sensors can be configured as Alarm, VerifiedAlarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only ,• Modules can be configured as Alarm, Latching Supervisory, Non-Latching Supervisory, Water Flow, Monitor, Trouble, Fire Drill Switch, Signal Silence Switch, Aux Disconnect Switch and Buzzer Silence Switch Base panel is equipped with Four Class "B" (Style "B') indicating circuits which may be configured as Class "A" (Style 'Z") using a Class "A" signal converter module Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test Subsequent,Jarm, Supervisory, and Trouble operation RS-485 Interface for Remote LED and LCD Annunciators, Interface for a Remote Trouble Indicator (RTI-1) Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events 5.5 Amp Power Supply Optional modules for additional internal relay circuits and City Tie/Polarity Reversal Complies with UL 864 9th Edition requirements Optional trim rings for semi-flush mounting X& 7165-1477:156 S7010 CATALOG NUMBER I U U I I u, y NOT TO BE USED FOR INSTALLATION PURPOSES. Mtrcom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. I 111111ii, MIRcQM' Canada U.S.A. 25 interchange Way 60 Industrial Parkway, PMB 278 Vaughan, Ontario L4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toil Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (886) 660-4113 Web page: http:llwww.mjrcom,com Email: maii@mircom.com Distributed by: ISO 90012000 REGISTERED ;fr U I I CAT. 5670 Rev. 0 Optional Adder Mod uJes :r., 4± — - OCAC-304 Four Indicating Circuit Class "A" Converter Module The OCAC-304 converts four Class "B" (Style "Y") output circuits on the FX-350 to Class 'A" (Style "Z") circuits. The OCAC-304 is equipped with wire leads to connect to the FX- 350 main board. Remote Annunciators ;t fVii 1 T - PR-300 Polarity Reversal/City Tie Module The PR-300 provides outputs for city box and polarity reversal applications. As a city tie module the PR-300 provides an interface between the control panel indicating circuits and a master box. As a polarity reversal module the PR-300 provides an interlace between the control panel and a reverse polarity receiver. RAM-300LCDR Remote LCD Annunciator The RAM-300LCDR provides LCD remote annunciation through a 2 line by 20 character LCD display. The RAM-300LCDR provides control switches for System Reset, Signal Silence, Fire Drill and Acknowledge as well as a numeric keypad to access the menu functions. The common control functions can be disabled on a per function basis. The RAM-300LCDR has LED indicators forA.C. On, Alarm, Supervisory, Trouble and CPU Fail. The RAM-300LCD comes complete with a red enclosure and a CAT-30 Lock and key. RAM-1 016/RAM-I 032 Remote LED Annunciators The RAM-1016 and RAM-1032 Remote LED Annunciator provide 16 or 32 points respectively of LED annunciation. Both models come standard with bi-coloured LEDs which are automatically configured for either Alarm (Red) or Supervisory (Amber). The annunciators have indicators forA.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. In addition both models allow for the control switches to be disabled on a per function basis. Both models mount in a BB-1001R enclosure. RAM-208R/RAM-216R Remote LED Annunciators The RAM-208R and RAM-216R provide 8 or 16 points respectively of LED annunciation. Both models feature bi-coloured LEDs which are auto-configurable for either Alarm (red) or Supervisory (amber). The LED annunciators have indicators forA.C. On, Common Trouble and Signal Silence and control switches for System Reset, Signal Silence, Lamp Test and Buzzer Silence. The RAM-208R and RAM-216R are equipped with a keyswitch which allows for enabling and disabling of the Common Control functions. Both models are available in a red finish and mount in a 4-gang electrical box. Ordering Information Model Description FX-360 Series Intelligent Fire Alarm Control Panels FX-350-60-DR Single Loop 60 Point Intelligent Fire Alarm Control Panel with built-in UDACT/Digital Communicator FX-350-126-DR Single Loop 126 Point Intelligent Fire Alarm Control Panel with built-in UDACT/Digital Communicator FA-300TRB Black semi-flush trim ring for FX-350 Series enclosures Optional Adder Modules OCAC-304 Four Indicating Circuit Class 'A' Converter Module PR-300 Polarity Reversal/City Tie Module Remote Annunciators RAM-300LCDR Remote LCD Annunciator RAM-1016 16 Zone Remote LED Annunciator RAM-1032 32 Zone Remote LED Annunciator BB-1001R Enclosure for RAM-1016 & RAM-1032 Annunciators RAM-208R 8 Zone Remote LED Annunciator RAM-216R 16 Zone Remote LED Annunciator NOT TO BE USED FOR INSTALLATION PURPOSES. I .. Appendix D: Power Supply and Battery Calculations Appendix D: Power Supply and Battery Calculations POWER REQUIREMENTS (ALL CURRENTS ARE IN AMPERES) Model Number Description I Qty STANDBY TOTAL II ALARM TOTAL STANDBY ALARM FX-350-60-R/ Main Panel X 0.200 0.370 = FX-350-1 26-R FX-350-60-DR/ Main Panel c/w Dialer X 0.220 = 0.380 = FX-350-126-DR 11 1 FX-351-LW Main Panel c/wi RAX- x 0.210 = 0.390 (Note 1) 332 LED Displays Main Panel, c/wi RAX- FX-351-LDW 332 LED Displays and X 0.230 = 0.400 (Note 1) = Dialer RAX-332 32 LED Display - X 0.005 = 0.010 = PR-300 Polarity Reversal and 0.050 = 0.300 City Tie Module - - RAM-300- Remote LCD X 0.016 = 0.040 = LCDW/R Annunciator RAM-208/216 Remote Annunciator, 8 x 0.0350 = 0.090 = Zone LED 11 Rh-i Remote Trouble x 0.035 = 0.035 = Indicator MIX-3000 Ionization Detector X 0.00028 = 0.00028 = MIX-3100 Photoelectric Detector X 0.00034 = 0.00034 = MIX-3200 Multi-sensor Detector X 0.00047 = 0.00047 = MIX-3300 Heat Detector X 0.00025 0.00025 = MIX-lOOP Priority Monitor Module X 0.00060 = 0.00060 MIX-1O1P Mini Priority Monitor X 0.00060 = 0.00060 = Module Apollo 55000-820 Relay Output Module X 0.00085 = 0.00085 MIX-100S Supervised Control X 0.00100 = 0.00100 = Module MIX-i OOX (Kit) 100XH (Isolator) Isolator c/w Mounting X 0.000035 0.000035 = Base 100XB (Base) MIX-2001R Relay Base X 0.000002 = 0.000040 Device LEDs (Maximum 15) - X I x I 0.0040 = Signal Load (bells, horns, strobes, and etc.) - = Auxiliary Power Supply for Annunciators, etc. (See Note 2) Total currents (Add above currents) STANDBY(A) ALARM (B) continued on next page MS-71 oiou Intelligent Addressable Dual Action Manual Station ALPHA INTELLIGENT ADDRESSABLE MANUAL STATIONS MS-700IDU SERIES MS-701 lDU Intelligent Addressable Single Action Manual Station Description Mircom's MS-7001DU Series provide manual fire reporting. These high quality, die-cast metal Intelligent Fire Alarm Manual Stations are available in either single or dual action configurations with a permanently attached addressable module. The MS-7001DU Series stations are available as single or dual-action devices with key resets and a permanently attached addressable module . The addressable manual station has DIP switches which allow for address setting. Pulling the handle initiates the operation of the addressable module. All models are available with CAT-30 keys and mount on a standard single gang backbox, Mircom model BB-700 interior surface metal backbox, or BB-700WP weather proof backbox. Operation The MS-7011DU Single Action Intelligent Manual Station is operated by pulling down the handle marked "PULL HANDLE" on the front of the station. The MS-7101DU Dual Action Intelligent Manual Station is operated by pushing the bar labelled "PUSH BAR" and then pulling down the handle marked "PULL HANDLE", The MS-70ClDU Series Manual Stations are reset by opening the station with the key, placing the handle in the normal upright position and re- locking the station. Features Single or Dual Action • Key resettable Permanently Attached Intelligent Addressable Module High-gloss red enamel finish Plastic breakrod Meets ADA 5 lb. maximum manual-force Mounts on standard single gang box, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox Specifications The manual station shall be Mircom's MS-700IDU Series. Operating instructions shall be in raised English lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the intelligent addressable module. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL codes, as well as all other applicable national or local codes. Final acceptance is subject to the local authority having jurisdiction. X@@ 7150-1477:128 S7005 S7005 I I I I I I I I I I I I I I CATALOG NUMBER SPA w W U W NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any lime without notice in prices, colours, materials. components, equipment. specifications and models and also to discontinue models. I Specifications Switch Rating: 1 Amp @ 30 VDC 0.1 Amp @ 125 VAC Manual Station Dimensions: 4.9 H x 3.5" W x 2.0 D Color: Red with raised white letters, white Manual bar with raised red letters. Surface Mount Backboxes BB-700 Surface Mount Backbox Dimensions: 5" H x 3.6W x 2.0 D BB-700WP Weatherproof Surface Mount Backbox Dimensions: 5" H x 3.6" W x 2.2" D Typical Wiring Diagram MS-7011DU and MS-7101DU I I 1 I I U Ordering Information MS-701 IOU Alpha Intelligent Addressable Key Resettable Single Action Manual Station MS-71010U Alpha Intelligent Addressable Key Resettable Dual Action Manual Station BB-700 Series 700 Interior Surface Mount Backbox, Red Finish BB-700WP Series 700 Weatherproof Surface Mount Backbox, Red Finish I NOT TO BE USED FOR INSTALLATION PURPOSES. - MIRcQ I Canada U.S.A. 25 Interchange Way 60 Industrial Parkway Vaughan, Ontario 1.4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 I Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web nen •. uIIlI(I(IIII.U(fl.cUUl . CAT. 5679 ISO 9OO120O0 (2t Rev 0 REGISTERED I ALPHA INTELLIGENT ADDRESSABLE DETECTORS MIX-3000 SERIES MIX-3000 MIX-3100 Ionization Smoke Detector Photoelectric Smoke Detector MIX-3200 MIX-3300 Multi-Sensor Detector Thermal Detector Description Mircom's Alpha Series Intelligent Addressable Detectors are designed to meet a wide range of applications. The detectors address is set in its base providing a convenient and trouble free maintenance procedure. The detectors mount into a selection of base styles to accommodate installation requirements. Intelligent Ionization Smoke Detector (MIX-3000) The Ionization smoke detector incorporates a unique dual chamber design to respond quickly and dependably to a broad range of fires. The ionization detector is equipped with a red LED which flashes when the detector is polled and turns on steady when the detector goes into alarm. (UL Listed) Intelligent Photoelectric Smoke Detector (MIX-3100) The Intelligent photoelectric smoke sensor utilizes a unique optical sensing chamber that is designed to sense smoke produced by a wide range of combustion sources. The photoelectric detector is equipped with a clear LED which flashes when the detector is polled and turns on steady when the detector goes into alarm. Features Low profile design For use with the FX-350 Series Fire Alarm Control Panels Fast response time Automatic addressing with the MIX-ADD card Variety of mounting bases Ease of installation Elegant, unobtrusive design Digital communications Intelligent Multi-Sensor Detector (MIX-3200) The Intelligent Multi-Sensor Detector is a photoelectric smoke detector with a supplementary thermal sensor. The Multi-Sensor detector combines photoelectric smoke and thermal sensor values to provide enhanced detection performance and reduction of false alarms. Information from each sensing element is processed and conditioned by an on-board advanced technology ASIC and digitally transmitted to the FACP as a single analog value comprised of the combined responses from both the photoelectric smoke and thermal detection elements. Intelligent Thermal Detector (MIX-3300) The Intelligent Thermal Detector utilizes state of the art electronic temperature sense to provide fast and accurate temperature monitoring. The thermal detector features an adjustable termperature range that is configured from the FX-350 Series fire alarm control panel. 0 & @ S6295 S6965 7271.1477:138 (MIX-3000, MIX-3100 (MIX-3100 (MIX-3000) 4 MIX-3200) & MIX-3200) 7272-1477:131 (MIX.3 100) S6299 S7498 7272-1477:142 (MIX-3300) (MlX.3300 727 0, 1477:139 CATALOG NUMBER t.. w i NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models, I MIX-ADD Address Card A unique, patented addressing method provides simple, user friendly and accurate identification of the detector location. AcodedMlX-ADD card is inserted in the base. This can then be read by any Alpha Series detector once it is plugged in. Using this method, all the electronic components are in the detector but the location information is held in the base. The MIX-ADD card simplifies and speeds up installation and commissioning. Addressing errors during maintenance and service are eliminated. Specifications General Specifications 16-28 VDC fbn Class A (Style D) or Class B (Style B) switch selectable 0% to 95% (No condensation or icing) MIX-3000 Ionization Detector 280 pA 4 mA MIX-3100 Photoelectic Detector 340 pA 4 mA Ordering Information 0°F to +155°F (-20°C to +70°C) mperre. ' , ?H{ i°Cr dUg White Polycarbonate MIX-3200 Multi-Sensor Detector 470 pA Jo 4 mA MIX-3300 Thermal Detector d 250 pA 4 mA *F *C 131'F to 194 (55 to 90 C) NMI MIX-3000 Intelligent Addressable Ionization Smoke Detector (UL Listed) MIX-3100 Intelligent Addressable Photoelectric Smoke Detector MIX-3200 Intelligent Addressable Multi-Sensor Detector MIX-3300 Intelligent Addressable Thermal Detector MIX -ADD Address Card for MIX-3000 Series Intelligent Detectors NOT TO BE USED FOR INSTALLATION OURPOSES. - 4h MRCOM I Canada U.S.A. 25 Interchange Way -60 Industrial Parkway, PMB 278 Vaughan, Ontario L4i< 5W3 Cheektowaga New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 6604655 I Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http://www.rnircorn.corn Email: mail@mircom.com ISO9001,2000 CAT. 5676 REGISTERED Rev. 0 AL PHA iINTELLIGENT A.1') *1: UE MODULES 'i I P6 LsI'ISERIES .' . -• ' ' EU-11 711 n *11 .-.------ MIX-lOOP MIX-100S Features Designed to meet a wide range of applications For use with the FX-350 Series Fire Alarm Control Panels Fast response time Priority Interrupt feature on monitor modules Monitor modules can be wired as a Class A (Style D) or Class B (Style B) Each module can be addressed from I to 126 Eight position dip switch for address setting Red light indicator Modules mount in standard 4" junction box I I I MIX-1O1P I I I I Description Mircom's Alpha Series Intelligent Addressable Modules are designed to meet a wide range of applications. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, waterfiow switches, conventional smoke detectors and more. An eight position dip switch allows for the address setting of the device and the wiring class/style of the devices that are connected to the module. All modules mount in a standard 4" x 4" x 2 1/8" junction box. Intelligent Addressable Priority Monitor Module (MIX-1 OOP) The Intelligent Addressable Priority Monitor Module (MIX-loop) provides an address for a group of UL/ ULC Listed normally open (NO.) initiating devices, such as heat detectors, beam smoke detectors, 4- wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-100P is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-100P has an activated red LED. Intelligent Addressable Priority Mini-Monitor Module (MIX-101P) The Intelligent Addressable Priority Mini Monitor Module provides an address for a group of UL/ULC Listed Normally Open (NO.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, waterfiow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-101P is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-101P has an activated red LED. Intelligent Addressable Single Relay Output Module (55000-820) The Intelligent Addressable Single Relay Output Module connects to the same loop as the initiating devices and provides one Form-C contact to control a variety of normally open or normally closed contact applications cuch as fan operation and door closures. 14@@ 7150-1477:156 S5434 S5434 I I 1 I I I I CATALOG NUMBER 4979 NOT TO BE USED FOR INSTALLATION PURPOSES, Mircom reserves the right to make changes at any time Without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. I MiRCOM I Canada U.S.A. 25 Interchange Way 60 Industrial Parkway, PMB 278 Vaughan, Ontario L4K 5W3 Cheektowaga, New York 14227 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 I Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http:/tw'ww.mircom.com I Email: mail@mircom.com Distributed by: 1509001:2000 CAT. 5675 REGISTERED -GM Rev. 0 Intelligent Addressable Supervised Control Module (MIX-100S) The MIX-100S Control module provides supervised monitoring of wiring to signal devices that require an external power supply to operate, such as horns, strobes, bells or speaker isolators. Conventional signals will require a 24 VDC power source and speakers will require an audio input. The red LED will illuminate when the module is activated. The module is capable of Class A (Style Z) or Class B (Style Y) supervision. Specifications General Specifications 16-28 VDC Zt Class A (Style 0) or Class B (Style B) switch selectable 0% to 95% (No condensation or icing) MIX-1 OOP and MIX-101P i •'.ga°.-4-°.•,'rr . -. . 600 pA larCurit " 4 mA (LED on) Djmenslons' . -. " MIX lOOP 40 Wx40 Hx13 D MIX -101P 30 Wx20 Hx075 D Welght ,,, I MIX -100P MIX 101P 3.0 oz. (858g) 1.5 oz (42.6g.) Fault Isolator Module (MIX-bOX) The MIX-bOX Fault Isolator Module is used to protect the system against wire-to-wire short circuits on the analog loop. The modules should be spaced between groups of sensors or modules in a loop to protect the rest of the loop. In the event of a short circuit between any two fault isolator modules, both modules immediately switch to an open circuit condition and isolate any group of sensors between them. The remaining units on the circuit will continue to operate in a normal fashion (must be wired in Class A or Style 6). 0°F to +155°F (-20°C to +70°C) ernptuSe i is 47 White Potycarbonate MIX-100X 35pA at 24V LlnoCu,rent 1 Amp tjR 0.2 ohm 40 Wx4 0 H xl 3 D 3.0 oz (85.8g) MIX-100S 1 mA -. Signals 24 VDC regulated Source,Power xll l Speakers 70.7 V RMS M N tins ' 2A c 3OVDC 0.6A @ 125VAC Dmenslons -,!. 40 Wx40 Hx1 3 0 3.0 oz. (858g) Ordering Information MIX-lOOP Intelligent Addressable Priority Monitor Module MIX-101P Intelligent Addressable Priority Mini Monitor Module MIX-100S Intelligent Addressable Supervised Control Module MIX-100x Fault Isolator Module 55000-820 Intelligent Addressable Single Relay Output Module - NOT TO BE USED FOR INSTALLATION PURPOSES. ZNH-R Red 0300 ZNH-W White 0301 Wall Mount Horn Strobe ZNS-MCW-FR Red 0304 ZNS-MCW-FW White 0305 ZNS-MCWH-FR Red 0306 ZNS-MCWH-FW White 0307 Ceiling Mount Horn Strobe ZNS-MCC-FW White 0311 ZNS-MCC-FR Red 0310 ZNS-MCCH-FW White 0313 ZNS-MCCH-FR Red 0312 UL Max. Current 15cd 30cd 75cd llOcd High (95) dBA 24 VDC. 0 0.244 Low (90) dBA 24 VDC 0.066 0.101 0.177 0.232 UL Max. Current 15cd 30cd 75cd 95cd High (95) dBA 24 VDC 0.082 0.124 0.209 0.275 Low(90)dBA 24 VOC 0.071 0.114 0.201 0.261 UL Max. Current UL Max. Current Audible ll5cd 177cd ------------ 24 VDC 12 VDC High (95) dBA 0.350 0.477 High (95) dBA 0.044 0.021 Low (90) dBA 0.306 0.429 Low (90) dBA 0.018 0.012 (800) 631-2148 www.cooperwheelock.com I 1 I p I 1-2 09/06 Features,ane.asy: snaponbase designed 1, Strobes to simlifytri&Snstallàtion and testing of strobes, horns and horn strobes. Available features and options: Color: Red or white Mounting: Wall or ceiling EZ mount SNAP design Universal mounting plate - single plate for wall and ceiling mount in- stallations Disposable cover to protect base plate Strobes produce 1 flash per sec- ond over the Regulated Voltage Range [I Wall Mount Strobes ZRS-MCW-FR Red ZRS-MCW-FW White ZRS-MCWH-FR Red ZRS-MCWH-FW White Ceiling Mount Strobes ZRS-MCC-FW White ZRS-MCC-FR Red ZRS-MCCH-FW White ZRS-MCCH-FR Red UL Max. Current l5cd 30cd 75cd 110cd 4085 .. 24 VDC 0.060 0.092 0.165 0.220 5242 ................................ 0303 UL Max. Current 135cd 185cd -. 24 VDC 0.300 0.420 0309 0308 UL Max. Current 15cd 30cd 75cd 95cd 0314 . :yp.c.. 0.249 5240 UL Max. Current 115cd 177cd 24 VDC 0.300 0.420 Horns and Horn Strobes Wall or Ceiling Mount Horn DH( )GC1 Electromagnetic Fire Door Holders OH Series DH( jFPC IPowdercoated) RSG 3300 E. 59th St. Long Beach, CA 90805 P: (562) 529 5,100 F: (562) 529 5102 www. rsgsecurity.corn Description: OH series fire door holders are constructed of the finest materials and workmanship available. The door holder is made of durable die-cast metal and offered in a high luster plated or powdercoated finish. Other features include standard dual voltg ac ur dc inputs of 12 & 24V, 24 & 120V and 24 & 220V models, While reducing stocking requi(ements, model 24120 draws a rnern 020 ma @24V00 lowering overall job costs in large installations the cost savings can be substantial). Other features: single or double coil floor mourning, surface mounting and direct wall mounting. No brackets are required. The OH series door holder offers a new installation technique using an adhesive template assuring alignment without secondary adjustments. Accessories include extension and misalignment rods (various lengths) enabling parallelism between door and wall at distances greater than 12 inches and misalignment over 4 inches. I Aiding in installation is the aircraft quality OH drill that reduces installation time and provides a near perfect alignment of catch-plate and armature - again, lowering overall installation costs. I Basic units offer supetior holding force and low residual magnetism, Models 1224 arid 24120 can operate at higher listed voltages producing hotding forces in excess of 10bs. (45.3kg.) For special applications. Extension Rod . ' I Dual Voltage Applications ' (re.aiw riw) hi\ I IL 4 . ,... / •'\"\ V 2. MADE r Tj I ( 1)) \ AMLKA U - .--------- - - - - OPTLOf'IALFEATURES TANDARD FEAiuRES PLATEDORPOWDERCOATEO rINISH VERY LOW CURRENT DRAW Db DUAL VOLTAGE lrpuT$. EXTENSION AND MISALIGNMENT RODS TERMINAL BLOCK CONNECTlONSf SURFCE1MOUNT BACKtBOX HIGH HOLDtNGFpRCE 1" TIME 'DRILL FIXTURE. LOWRESIDUAL.'MAGNETlSM I (FOR MOUNTING CATCH PLA'rC) DOUBLE CHROMEPLATING - . ..' . MOUNTING ARDWARE&INSTRJGoSJL4 --------- Surface Mounting: DHBB (back box) 0 3I. PERFORMANCE DATA: MODEL VOLTAGE DC/mA AClmA Terminals LB. KG. 1224 12V 40 38 C&L 30 13.6 24V 40 36 C&H 30 13.6 24V 20 19 C&L 40 16.1 24120 120V -- 20 C&H 35 15.8 24420 24V 20 19 C&L 40 181 220V ---- 15 C&H j 25 1 11.3 NOTE: Holding forces listed in above table Correspond WIfl shaded values, non shaded values are slightly less. MODEL VOLTAGE DClmA AC/ijiA Terminals LB. KG. 1,224 24V 85 5' C&L 75 34.0 24120 120V .100 110 49.8 HIGH HOLDING FORCESPECLAL ,APPLICKHOI'IS. To obtain pei'formance values in table above apply hgh listed voltage to low voltage terminals (C & Li NOTE: This configuration can only be applied to models 1224 & 24,120 ACCESSORIES ORDERING INFORMATION: DH = 0o(* Holder F = Flush Mount S = Surface Mount R Recessed G Ground Mount P Powdercoated C = Chrome Plating B 7= Brass Plating 1 = Single Coil 2 = Double Coll NOTE: #2 indicates double Coil ground mount model, Example DH 24120) (S) (P) (C) (1) Door holder Mode.liVoltaqe 12-24,24120.24220 Mount Style Surface. Flush. Ground, Recessed Powc$ercoated Brass I I I I I I I I I I I I I I Extensions: Extension rods : I I i4 Extension :--- Wre'rtches Installation Tools: DHDF (drill,fixture) I • -4~ U I 1,2 ACCESSORIES: Extensions: DHE1C 1 inch extension chrome. DHE1B 1 inch extension brass. DHE15C 1-1/2 inch extension chrome. DHE158 1-1/2 inch extension brass. DHE2C 2 inch extension chrome. DHE28 2 inch extension brass. DHE3C 3 inch extension chrome, DHE3B 3 inch extension brass. DHEAC 4 inch adjustable extension chrome. DHEAB 4 Inch adjustable extension brass. Hardware: OHCPC Catch plate asseb1y' DHGPB chrome, Catch plate asseipjt)4y brass DHDC Catch disc DHDB Catch DHBBC DHBBB DHW DHDF ' tJpitlg ture'r MD-815 FX-350/FX-351 Mainboard - with Dialer MD-837 FX-350/FX-351 Mainboard - No Dialer MD-749 DSP Core Board MD-819 Power Supply Board PR-300 City Tie/Polarity Reversal TR-061 120/240 VAC Transformer CH-613 FX-350 Backbox CH-641 FX-350 Door CH-642 FX-350 Deadfront CH-643 FX-351 Deadfront CH-644 FX-351 Door CH-645 FX-351 Backbox MD-825 RAX 232 RAM-300-LCD Remote LCD Annunciator MIX-3000 Addressable Ion Smoke Detector (CSFM# 7271-1477:138) MIX-3100 Addressable Photoelectric Smoke Detector (CSFM# 7272-1477:131) MIX-3200 Addressable Photo/Heat Detector (CSFM# 7272-1477:142) MIX-3300 Addressable Heat Detector (CSFM# 7270-1477:139) MIX-2000-2001 Standard Base (CSFM# 7300-1477:145) MIX-2001 R Standard Base with Relay (CSFM# 7300-1477:145) MIX-lOOP Priority Monitor Module MIX-1O1P Mini Priority Monitory Module MIX-loos Supervised Control Module MIX-bOX Isolator Kit 120 VAC, 60Hz 240 VAC, 50 Hz CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1477:156 Page 1 of 2 CATEGORY: Control Unit (Non High-Rise) LISTEE: Mircom Technologies Ltd., 25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 DESIGN: Models FX-350-60-R, FX-350-60-DR, FX-350-1 26-R, FX-350-1 26-DR, FX-351 -LW and FX-351-LDW fire alarm control units. Local, auxiliary, remote station (PPU), central station (PPU), waterflow and sprinkler supervisory services. Refer to the listee's data sheet for detailed product description and operational considerations. System components: I I I I I I I I I I I I I RATING INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with listee's separately listed electrically and functionally compatible initiating and indicating devices as indicated in design. Refer to listee's Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. I I I L 111 I I I Page 2 of 2 7165-1477:156 NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. This control panel meets the requirements of UL-864, 9 Edition. 05-23-2007 iw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JULY 17, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager I LISTING No. I CATEGORY: LISTEE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7150-1477:128 Page 1 of 1 Boxes/Pull Stations Mircom Technologies Ltd, 25 Interchange Way, Vaughan, Ontario, Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 DESIGN: Models MS-701U,-703U, 704U,-710U. -713U, -714U, 7O1ADU, -71 OADU, -702U, -7O2ADU, -701UP, -710UP, -703U(C), -704U(C), •713U(C), -714U(C), -705U, -715U,-706U(C), - 716U(C), -707U(C), -717U(C) and *..708 fire alarm boxes. These devices are manually actuated, single or dual action non-coded, fire alarm boxes. Units are to be mounted on standard outlet boxes or listee's Model BB-700 backbox for indoor use only and BB-700WP backbox for indoor and outdoor use. *Models MS- 7011D(U), -7021D(U) and -71010(U) non-coded, indoor use only, fire alarm boxes. To be mounted on three-inch deep outlet boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC, 1A, 125 VAC, 1A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-22-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 27, 2007 Listing Expires June 30, 2008 Authorized By.. MIKE TANAKA, Senior Deputy State Fire Marshal I Program Manager I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1477:142 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Mircom Technologies Ltd 25 Interchange Way, Vaughan, Ontario Canada L4K 5W3 Contact: Mara Cherubin (888) 660-4655 FAX (888) 660-4113 DESIGN: Model MIX-3200 photoelectric type smoke detector. Unit employs an integral supplemental heat sensor and is not intended for use as a required heat detector. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units and listed Models MIX-2000 Series detector bases (CSFM Listing No. 7300- 1477:145). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF 7272-1394:113 04-06-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 27, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager I LISTING No. I CATEGORY LISTEE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1394:108 Page 1 of 1 Misc. Devices/Control Unit Accessories *Apollo Fire Detectors Ltd, 36 Brookside Road, Havant, Hampshire, P09 1JR, England *Contact: Gordon Ash +44(0)23 9249 2412 FAX +44(0)23 9249 2754 DESIGN: *XP95A analog addressable signaling/contact monitoring modules. Model 55000-805 switch monitor module, Model 55000-806 priority switch monitor module, Model 55000- 820 switch monitor input-output module. Model 55000-825 sounder control module, Model 55000-830 mini priority switch monitor module and Model 55000-831 mini switch monitor module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: *Electrical: 17 to 28 VDC, 5 to 9 V protocol INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as monitoring modules for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Rev. 06-20-03KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued:, JUNE 8, 2007 Listing Expires June 30, 2008 I Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7135-0785:150 . Page 1 of 1 CATEGORY: Audible Devices I LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 I DESIGN: Models MIZ-TC12, MIZ-TC24, *M1Z12S and *MIZ 24S electronic horns. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: MlZ-TC12, *M1Z12S = 12V Nominal, 8-17.5V DC, 17mA max. MlZ-TC24, *Mlz24S = 24V Nominal, 16-33V DC, 24mA max. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. I APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. *For indoor use only. Models MIZ-1 2S and MIZ-24S are suitable for synchronization when used in conjunction with Models SM-12/23, SMX-12/24, DSM-12/24, DSMX-12/24 (CSFM I Listing No. 7300-0785:132) Sync Control Modules. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation I Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. I Rev 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marsha/ Program Manager I I I I I I I I I I I I I 1 I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:142 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc. 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Models NH-12/24, NH-12/24R, and *ZNH horns and Models NS-1215W, NS-121575W, NS-2415W, NS-241575W, NS-2430W, NS-2475W and NS-24110W; NS4-1215W, NS4- 121575W, NS4-241 5W, NS4-241 575W, NS4-2430W, NS4-2475W and NS4-241 lOW, NS-24MCW, NS4-24MCW, NS-24MCC, NS-24MCCH, *ZNSMCW *ZNSMCC *zNs MCWH and *ZNSMCCH horn strobes. Model number may be followed by any two- alpha/numeric characters indicating lens, lettering and color. Units are synchronized or non-synchronized strobes. Models NH-12/24R, NS-24MCC, NS-24MCCH, *ZNS MOO and 'ZNS MCCH are ceiling mount only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical-Strobe Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Candela: 15=15cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110110cd (Wall) NS-24MCW, NS4-24MCW, *ZNS..MCW: Selectable 15cd, 30cd, 75cd, 110cd *NS24MCC *ZNSMOO: Selectable 15cd, 30cd, 75cd, 95cd *NS24MCCH *ZNS.MOOH: Selectable 115cd, 177cd *ZNSMCWH: Selectable 135cd, 185cd Flash rate: 60 Flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. *All units are for wall mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label. APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed electrically compatible fire alarm control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only except for model NH-12/24 horn. All synchronization strobes shall be used with Models SM-12124, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132). Refer to manufacturer's installation manual for details. NOTE: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or / recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By.. MIKE TANAKA, Senior Deputy State Fire Marsha/ Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP4#W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24M0W and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRSMCC *ZRSMCW *ZRS.MCCH and *ZRS..MCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 =16-33VDC1FWR Candela 15=5cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110=110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRS MOW: Selectable 15cd, 30cd, 75cd or ll0cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRSMCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRSMCWH: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRSMCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listees name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. *Rev. 12-13-20061w 11 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: Authorized By JUNE 4, 2007 Listing Expires June 30, 2008 MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listees data sheet for detailed product description and operational considerations RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd, 177cd INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. I Rev. 06.13-06 I I I I I I I I I I Listing No. 7125-0785:131 Page 2 of 2 I MARKING: Listee's name, model number, electrical/candela rating, and UL label. I APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-1 2WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- U 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listees Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. I I I I Ii I I I 1 *Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or '+ recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3550-1039:100 Page 1 of 1 CATEGORY: Door Closer/Holders/Releasing Devices LISTEE: RSG, 3300 E. 59th St. Long Beach CA 90805 Contact: Louis Finkle *(562) 630-4684 FAX (562) 529-5100 DESIGN: Models DH-1 2, -24, -120, -1224,-24120, and -24220 door closer/holders. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 12V, 24V, 120V, and 220V INSTALLATION: In accordance with listees printed installation instructions and applicable codes and ordinances. The system is intended to be mounted in a horizontal position only. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as door closer/holders for use with separately listed compatible detectors and fire alarm control units. Rev. 06-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 1, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager