HomeMy WebLinkAbout6628 SANTA ISABEL; ; FA100057; PermitUltyotuarisbaci N Fire Alarm Permit Permit No: FA1 00057 6628 SANTA ISABEL Job Address: Status: ISSUED ST Permit Type: FALARM Applied 9/21/2010 Parcel No: 2153300100 Approved: 9/21/2010 Lot #: 0 Reference No.: Issued: 9/21/2010 PC #: Inspector: Project Title: ST. ELIZABETH SETON CHURCH TWO FIRE ALARM INSPECTIONS @ $65/EA Applicant: Owner ROMAN CATHOLIC BISHOP OF SAN DIEGO P0 BOX 85728 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0. 130 0 Iloilo Review Comments - St. Elizabeth Seton Catholic Church Fire Alarms, Carlsbad, CA We strongly recommend the following operational tests be performed once the system installation has been completed. A "power off' test, where the normal power supply is shut off, and the system is left to function on battery power alone for a period of 24 hours, at which time the system should still be functioning and operational. At the end of the end of the above test, prior to the primary power being restored, the systemS should be placed in an "alarm" condition for a period of not less than five minutes, during which time all notification appliances, including the off-station notification, are to function as designed. Once the two prior tests have been completed, the current level in the batteries should be checked, the primary power restored, and at the end of 48 hours the current level checked again to verify that the charging function of the panel is both operational, and able to recharge the batteries within the time period specified by NFPA-72. Once the test in item "c" has been completed, one of the leads to the battery should be disconnected, to determine that the system will provide notification of an "off-normal" power condition to the monitoring company. FILE COPY Implopip E[MUERFRMES FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS APPR oOS SUBMErTED 0 ST. ELIZABETH SETON CATHOLIC CHURCH 6628 SANTA ISABEL ST. CARLSBAD, CA FIRE ALARM SYSTEM The WU% he L hk CI tnd If 1113~ in in bw tile jut Tti n utitl/C ' in usW tot 011, ih the e dNtth1dut ti this CC, tvW i% ss tve the w ec o etutui thcti• 'el I%st tl ivicer o I t111 colPt CC 3Id tt I,C ttid fill i,eIudfl the hU%IdII Ct or cor any.re'.P0 thY lOt crrt'r or i%e n plan'. '.owther ornot fl Date 9/pci/to RCVICWeIt() 0 iuCOMM' AppIO VAL. AS t.40TEO FILE COPY ST. ELIZABETH SETON CATHOLIC CHURCH 6628 SANTA ISABEL ST. CARLSBAD, CA BILL OF MATERIALS NOTIFIER NFW2-I00 FIRE ALARM CONTROL PANEL WITH XRM-24 CSFM# 7165-0028:235 NOTIFIER NFV-25/50 EMERGENCY VOICE EVACUATION CONTROL PANEL CSFM# 6911-0028:229 NOTIFIER FDU-80 REMOTE ANNUNCIATOR CSFM# 7120-0028:209 NOTIFIER NH-I00 HEAT DETECTOR CSFM# 7270-0028.-234 NOTIFIER NOT-BG I2LX ADDRESSABLE PULL STATION CSFM# 7150-0028:199 NOTIFIER NP-100 ADDRESSABLE SMOKE DETECTOR CSFM# 7272-0028.231 NOTIFIER NMM-100P ADDRESSABLE MONITOR MODULE CSFM# 7300-0028:230 NOTIFIER NC-I OOR ADDRESSABLE RELAY MODULE CSFM# 7300-0028.230 WHEELOCK E70 SERIES SPEAKER/S TROBE WALL MT. COMBINATION CSFM# 7125-0785:152 WHEELOCK E90 SERIES SPEAKER/STROBE CEILING MT. COMBINATION CSFM# 7125-0785:152 WHEELOCK EXCEDER STCW CEILING MOUNTED STROBE ONLY, WHITE CSFM# 7125-0785:168 WHEELOCK EXCEDER STR WALL MT. STROBE ONLY, RED CSFM# 7125-0785:168 DN-6041 7:C FireWardenu100-2(E) Rev 2 NOTI Fl E R Intelligent Addressable FACP O~M_' with Built-In Communciator by Honeywell 1 II General - The Notifier FireWarden-100-2 Rev 2 (NFW2-100 Rev 2) with Version 4.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Comm unicalorflrans- mitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. The SLC (Signaling Line Circuit) of the FireWarden-100-2 Rev 2 operates using a Rapid Group Polling communication proto- col technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an inci- dent and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The FireWarden-100-2 Rev 2's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is completed, the electronics can be quickly installed with just two bolts. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools, the Upload/ Download software kit, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history tile, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other program- ming information. Version 4.0 firmware supports the following: ANN-bus devices, NP-A100, USB port, NAG circuit diagnostics, a new report has been added to the walk-test that lists untested devices, new device types added: audio telephone type code for NFV-25/ 50ZST, Photo Supervisory and auto-resettable Drill (non- latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term "Fire Warden- 100-2" is used in this document to refer to both the Fire Warden-100-2 and the Fire Warden-100-2E FACPs (Fire Alarm Control Panels). Like- wise, "NFW2- 100" refers to NFW2-lOOE as well. Features Listed to UL standard 864, 9th edition. On-board DACT. Remote site or local USB port upload/download, using PS- Toots. Four Style Y (Class B) or two Class A (Style Z) NAG cir- cuits. (Up to 6.0 amps total NAG power when using optional XRM-24B.) Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or FDU-80, N-ANN-80 or ACS Annunciators. ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): - N-ANN-80(-W) Remote LCD Annunciatcr - N-ANN-I/O LED Driver - N-ANN-S/PG Printer Module - N-ANN-RLY Relay Module - N-ANN-LED Annunciator Module - N-ANN-RLED Annunciator Module alarms only ACS & Terminal-mode Annunciators: - ACS Annunciators: Up to 32 ACM Series annunciators (ACM-16AT or ACM-32 series). Cannot be used if ANN- BUS devices are used. - Terminal-mode Annunciators: Up to 32 FDU-80 annuncia- tors. ElA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6. Integral 80-character LCD display with backlighting. DN-60417:C• 12/17/2009—Page 1016 Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History tile with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterf low (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10.000 ft. (3,000 m.). See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAG capability using output control modules (NC-100). The four Class B NACs can be converted to two Class A NACs with NACKEY (included). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAG. 2.5 amps maximum per each NAG circuit. NOTE: Maximum 24VDC system power output is shared among all NAC circuits and 24VDC special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-248 transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable). 99 software zones. Continuous tire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (NFW2-100 requires PS-Tools Programming software, available on VFWARDEN-CD and www.magni-tire.com). Upload/download system programming locally to the Fire- Warden-100-2(E) Rev 2 in less than one minute. USB programming with standard Male-A to Male-B cable. User interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Page 2 of 6— DNi-60417:C • 12)17/2009 Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information NFW2-100 Rev 2: FireWarden-100-2 Rev 2 198-point addres- sable Fire Alarm Control Panel, one SLC loop. Includes 80- character LCD display, single printed circuit board mounted on chassis, and cabinet. 120 VAC operation. NFW2-100R: Same as NFW2-100 Rev 2, except in a red backbox. NFW2-100E: Same as NFW2-100 Rev 2, except with 240 VAC operation. 4XTM Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. VFWARDEN-CD: Contains PS-Tools Programming software for Windows®-based PC computer (cable not included). DP-9692B: Optional dress panel for FireWarden-100-2 Rev 2. TR-CE-B: Trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 26 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional NFS- LBB for mounting. NOTE: CHG-120 or GHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E Rev 2. PRT/PK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet dn-60408 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclo- sure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPA TIBLE ANNUNCIA TORS N-ANN-80(-W): LCD Annunciator is a remote LCD annuncia- tor that mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is black; order -w version for white; see DN-71 14.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red or black enclosure (see DN-60242). N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242). N-ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See ON- 7107.) N-ANN-SIPG: Serial/Parallel Printer Gateway module pro- vides a connection for a serial or parallel printer. (See ON- 7 103.) N-ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DN-7105.) ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. ACM Annunciator Series: LED-type tire annunciators capa- ble of providing up to 99 software zones of annunciation. Avail- able in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80 (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the Fire Warden- 100-2 Rev 2, see the following data sheets (document numbers) ACM-8R (DN-3558), ACS/ACM Series (ON- 0524), LOM Series (DN-0551), FOU-80 (DN-6820). COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. NP-lOOT: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. NH-100: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heal detector with rate- of-rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. NP-Al 00(A): Addressable low-profile multi-sensor detector. ND-100: Photoelectric low-flow duct smoke detector. DNR(A): Innovair Flex low-flow non-relay duct-detector hous- ing. (Order NP-100 separately.) DNRW: lnnovair Flex low-flow non-relay duct-detector hous- ing, with NEMA-4 rating. Watertight. (Order NP-100 sepa- rately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0 (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only lDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional Iwo-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0° (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC-1001`11: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-lSO: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the NMM-100P. NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-25. NZM-100-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a BB- XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-25. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden- 100-2 Rev 2, see the following data sheets (document numbers): N100-ISO (DN-6994), NP-100 series (ON-6995), NI-100 (DN-6996), NH-100 series (DN-6997), ND-100 series (DN-7006), NP-A100 (DN-6998), NMM- 100/NMM- loop, NDM- 100/NZM- 100 (DN-6999), NC- 100/NC- IOOR (DN-7000), NOT-BG I2LX (DN-7001), NMM- 100-10 (DN-6990), and NZM- 100- 6 (DN-60 150). Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm') and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. DN-6041 7:C • 12/17/2009 - Page 3016 EIA-232 INTERFACE (PIM-24) built into the motherboard FireWarden-100-2 Rev 2 Fire Alarm Control! Communicator *- ANN-BUS ____ or ANN-BUS DEVICES EIA-485 N-ANN-80, N-ANN-LED, in ACS mode N-ANN-S/PG. N-ANN-1/0 (two wires) NOTE: System can use either ANN-BUS devices OR ACS-mode annunciators. They cannot be used simultaneously. LJ Pi Optional REVERSE POLARITY! CITY BOX OUTPUT (4XTM) 8 FORM-C, 5-AMP RELAYS (optional, order ACM-8R) * NACs (Notification Appliance Circuits) BELLS, SIGNALS, STROBES 0. I I SMOKE DETECTORS NP-100, NP-100T, NI-1 00, NP-A100 HEAT DETECTORS NI-l-100, NH-100R, NH-100H DUCT DETECTORS ND-100, ND-100R, DNR MON ITORJCO NTROL NMM-100, NZM-100, NDM-100, N100-ISO, NC-100, NC-10013 0 —*1111 11 1j ADDRESSABLE MULTI-MODULE NZM-100-6, NMM-100-10 EIA-485 INTERFACE (four wires) NOTE: System can use either the printer OR the FDU-80. They cannot be used simultaneously. 24 VDC MINI-MONITOR NMM-100P CD CD 0 0 ELJ FDU-80 Up to 6,000 ft. (1825.8 m) between each FDU-80 in the ElA-485 loop, and between each FDU-80 and the FACP. PULL STATION NOT-BG1 2LX Page 4016— ON-60417:C • 12/17/2009 DN-60417:C • 12/17/2009 -Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits.......................................1 Addressable device capacity ..........................................198 Programmable software zones.........................................99 ACS Annunciators ............................................................32 ANN-bus devices................................................................8 Electrical Specifications AC Power: FireWarden-100-2 Rev 2: 120 VAC, 60 Hz, 3.0 amps. FireWarden-100-2 Rev 2(E): 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery: Two 12 V 18AH lead-acid batteries. Battery charger capacity: 7-18 AH. FireWarden-100-2 Rev 2 cabinet holds maximum of two 18 AH batteries. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style V (Class B) or one Style Z (Class A) for a total of four Style V (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to panel documen- tation and Notifier Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Power (24 VDC Nominal): Jumper selectable (JP4) for conversion to resettable power output. Up to 0.3 amps total DC current available from each output. Power-limited. Four-Wire Resettable Special Application Smoke Detector Power (24 VDC nominal): Up to 0.3 amps for powering four- wire smoke detectors. Power-limited. Refer to the Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 40 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26 (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12' (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TR-CE-B): 22.00" (55.88 cm.) high x 19.65' (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0- 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F NFPA Standards The FireWarden-100-2 Rev 2 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). - CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic FireWar- den-100-2 Rev 2 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 FM approved CSFM: 7165-0028:235 MEA: 120-06-E, Volume 2 FireWarden® and Notitier® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks at the Microsoft Corporation. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. _____________ We cannot cover all specific applications Or anticipate all requirements. F ENCINFERINC & MIIIFACTIRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S,A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 6 of 6— DN-60417:C • 12/17/2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7165-0028:0235 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models Fire Warden 100 and *Fire Warden 100-2 addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). This panel also can be used with NFV-25/50ZST (Fire Voice-25/-50ZST) Zoned System Voice with Telephone for Emergency Voice evacuation Applications. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 7165-0075:0208 'Rev. 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational ' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division DN-7004:A1 - C-10 II'fr4.1iI' FireVoice-25/50 0 Voice Evacuation Control Panel by Honeywell ;'A ControL System5j . . General The FireVoice-25/50 (NFV-25/50) is a state-of-the-art, single- or dual-circuit (25 watts each) Emergency Voice Evacuation Control Panel (EVAC). The NFV-25/50 records five field-pro- grammable messages (up to 60 seconds total message dura- tion) with an integral commercial-grade emergency communications microphone or from an external audio source. Significant technological enhancements set the NFV-25/50 apart from other EVAC panels - these include full supervision in both active (alarm or music) and standby conditions, super- vision of amplifier outputs, field wiring, message generator, all tone generators, and the microphone. The integral power sup- ply charges up to 18 AH batteries, which can be housed in the NFV-25/50 cabinet. The NFV-25/50 is suitable for use as an adjunct (slave or stand-alone) to most UL-Listed Fire Alarm Control Panels (FACPs). An optional 25 watt, 25 VRMS audio amplifier is available for system expansion to 50 watts (providing dual 25- watt speaker circuits) or as a secondary amplifier in jurisdic- tions requiring backup. A 70.7 VRMS converter is also avail- able for independently converting amplifiers to meet retrofit needs. A host of field-programming options, including the capability of five custom messages (fire, tornado, evacuation, hazmat, non- fire, multi-language, etc.) make the NFV-25/50 the most versa- tile voice evacuation system available. Suitable Applications include schools, auditoriums, dormito- ries, theatres, restaurants, places of worship, lodging, office buildings, and factories. Standard Features Listed to UL Standard 864, 9th edition. Integral 25 watt, 25 VRMS audio amplifier with single Style Z (Class A) or Style V (Class B) speaker circuit (expandable to 50 watts using the ACC-AAM25). Modular design for maximum system flexibility and ease of service. Five Command Input Circuits (CMD) are available for acti- vation by an FACP. Two command input circuits can be independently field-pro- grammed for activation by a Notification Appliance Circuit (NAC) or contact closure. Three command input circuits activate on contact closure. Manual deactivation of speaker zones. Command inputs allow: - One 60-second message. - Two 30-second messages. - Three 20-second messages. - Four 15-second messages. - Five 12-second messages. Microphone lime-out feature. Nineteen different system and diagnostic LEDs. Two Form-C trouble relays (System & AC Power Loss). Optional equipment: second amplifier; local playback speaker; and remote microphone. Integral digital message generator with standard, factory prerecorded emergency evacuation message. Custom messages are field recordable, using the integral microphone or the audio input jack. Digital message may be field-selected for 3, 4, 6, 8, or infi- nite repeat. Built-in alert tone generators with steady, slow whoop, high/ low, or chime tone capability. Field-selectable lead-in/trailing tone selection. Alert tone selection may be field-programmed to conform with ANSI S3.41 Audible Emergency Evacuation Signal (Temporal Pattern), per NFPA. Speaker zone control via CMD inputs or keypad. Dual-optically-isolated, trigger input circuits are indepen- dently field-programmable for activation by polarity reversal (host FACP NAC) or dry-contact closure. Zone 1 switch-programmable for All-Call operation. Integral diagnostic LEDs include: Power, System Trouble, Microphone Trouble, Message Generator Trouble, Tone Generator Trouble, Amplifier Fault, and others. Independent Form-C trouble relay allows FACP to monitor voice system while in active (alarm) state. Integral piezo provides local audible indication for troubles. Fully supervised in Standby and Active states, including integral microphone, amplifier output, message generator, speaker wiring, and tone generators. Independent amplifier supervision: current limit, audio level, short circuit protection. All outputs are power-limited. Auxiliary power output provides local power for addressable control modules when used to activate the NFV-25/50. Compatible with all NOTIFIER FACPs, as well as other manufacturers' panels. Background music capability (requires AHJ approval). When using the background music option, total output power per amplifier is reduced to 20 watts. DN-7004:A1 • 1/13/10—Page 1014 Optional Modules ACC-AAM25: 25 watt, 25 VRMS audio amplifier module. Field-programmable for system expansion to 50 watts (provid- ing dual 25-watt speaker circuits) or as a backup to the primary 25-watt amplifier where required. Single Class A or Class B speaker circuit. Plug-in-style terminal blocks for ease of ser- vice and maintenance. Fully supervised and power-limited. Diagnostic LEDs include: yellow "trouble" LED (cable fault, 70 VRMS fault, amp fault) and green "amp functional" LED. FC-XRM70: Converts 25 VRMS audio outputs to 70.7 VRMS for retrofit applications. Plugs directly on ACC-AAM25 mod- ule(s), allowing independent conversion to 70.7 VRMS. FC-LPS: Local digital message playback for user review of field-recorded custom messages. BAT Series: Two batteries required. See FACP manual for specific current requirements. See data sheet for overview of batteries. NFV-TR: Optional trim ring for semi-flush mounting VEC-RM: Optional remote microphone, includes backbox. Only one VEC-RMper system. Specifications Command input circuits (CMD1 and CMD2): Trigger input voltage: 10.5-29 VDC. NOTE: When programmed for reverse-polarity activation. Trouble contact rating: 2.0 A at 30 VDC (resistive), 0.6 A @ 125 VAC (resistive). Auxiliary power output: Specific application power: 24 V, 35 mA. Primary (AC) power: 1.6 A maximum @ 120 VAC, 50/60 Hz. Secondary power (battery) charging circuit: Supports lead- acid batteries only. Float-charge voltage: 27.6 V. Maximum charge current: 800 mA. Maximum battery charging capacity: 18 AH. Cabinet Specifications Door: 26.174" (66.482 cm) high x 15.780" (40.081 cm) wide x 1.125" (2.858 cm) deep. Backbox: 26.0" (66.040 cm) high x 15.5" (39.370 cm) wide x 4.75" (12.065 cm) deep, depth includes door. Controls and Indicators LED INDICATORS Power On (green). System Trouble (yellow). Message Generator Trouble (yellow). Tone Generator Trouble (yellow). Microphone Trouble (yellow). Record/Playback (green). Zone 1 (green = Active, yellow = Manual Deactivation). Zone 2 (green = Active, yellow = Manual Deactivation). Other system LEDs: Battery Trouble, Charger Trouble, Ground Fault, Speaker Circuit Trouble, and Amplifier Supervisory. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 491C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in al, environment with a normal room temperature of 15 - 27°C/60 - 80°F. Standards and Codes The NFV-25/50 complies with the following standards: NFPA 72 National Fire Alarm Code; NFPA 101 Life Safety Code; UL 864 Standard for Control Units for Fire Alarm Systems. Listings and Approvals These listings and approvals apply to the basic NFV-25/50. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL Listed: S635 (Standard 864 9th Edition) CSFM: 6911-0028:229 MEA: 341-03-E Vol 2 (NFV-25/50, ACC-AAM25) Product Line Information NFV-25/50: 25 watt, 25 VRMS, Emergency Voice Evacuation Control Panel with integral commercial microphone, digital message generator, and single-/dual channel Class A or Class B speaker circuits. ACC-AAM25: Optional 25 watt, 25 VRMS Audio Amplifier Module with single Class A or Class B speaker circuit. FC-XRM70: optional 70.7 VRMS Converter Module (one required per amplifier). FC-LPS: optional Local Playback Speaker. BAT Series: Two batteries required. See FACP manual for specific current requirements. See data sheet for overview of batteries. NFV-TR: Optional trim ring for semi-flush mounting. VEC-RM: Optional remote microphone, includes backbox. Only one VEC-RMper system. Application Examples The FireVoice-25/50 is a voice evacuation control panel which can be used with a variety of FACPs for emergency audio messages. Two typical application examples follow. One Speaker Circuit Single output zone, single input circuit (SEE FIGURE 1). A very basic application is one NFV-25/50 with one amplifier and a single speaker circuit. This configuration is suitable for small facilities requiring no more than 25 watts of output power. A single fire evacuation message will be initiated during an alarm condition from the host FACP or can be manually started with a message push-button. The NAC from the host FACP is connected to CMD1. The CMD1 'out' terminals are then terminated with an end-of-line resistor for the FACP's Style V NAC, or the terminals are wired back to the host FACP for a Style Z NAC. S3 DIP switches "1", "2", and "3" are set to OFF; this selection sendr a 60-second message to the speaker circuit when the CMD1 input is acti- vated. The S5 DIP switch "5" is set to OFF; this selection acti- vates the CMD1 input by a reverse-polarity condition. CMD3, CMD4, and CMD5 inputs require end-of-line resistors. The system may also be manually activated from the keypad. Press the Building Speakers button, then press the Fire Mes- sage button. Or use the microphone to make an announcement. Page 2 of 4— DN-7004:A1 • 1113110 rn FIRE MESSAGE POWER ON - SYSTEM TROUBLE MESSAGE GENERATOR TROUBLE TONE GENERATOR MICROPHONE TROUBLE RECORD PLAYBACK TROUBLE SILENCE • rn • Keypad Example HOST FACP NAC style FACP EOLR ((or Style Y only) 4.75K ohm EOIRs. P114 75470 100 (02)6 T86 ATB2TB5 0 TB8 '0 TB9 1 2 34 1 2 4 172394 MASTER CMDI IN CMO2 IN CMD3 CMD4 CMD5 CMD OUT alarm polarities shown A FireVoice-25/50 Main Circuit Board style Z_ I III supervisory polarity shown TBI SPEAKER 182 BACKUP FIRST AMPLIFIER mounted on main circuit board Figure 1: One 25 Watt Speaker Circuit NOTE: EOLR required only for Style Y (Class B). 4.75K ohm, I NOTE: Typical illustration of an addressable NOTIFIER control watt, P/N 75470. panel and addressable control modules. Refer to manual for volt- age ranges, message control switch settings, and command input specifications. DN-7004:A1 • 1/13/ 0— Page 30(4 powsio AUDITORIUM SPEAKERS CLASSROOM SPEAKERS SYSTEM TROUBLE FIRE MESSAGE ff). MESSAGE GENERATOR TROUBLE TONE GENERATOR TROUBLE • MICROPHONE TROUBLE - RECORD U PLAYBACK T5=EE Keypad Example TWO SPEAKER CIRCUITS Dual output zone, dual input circuit - tone/voice message (SEE FIGURE 2). This application example has of one NFV- 25/50 with two speaker circuits and requires the installation of a second amplifier. This configuration is suitable for small facil- ities requiring no more than 50 watts of output power and a 60- second fire evacuation message. The addressable FACP directs tone or voice messages to either of the speaker circuits via the control modules con- nected to the CMD1 and CMD2 inputs. S3 DIP switches "1", "2", and "3" are set to OFF; this selection configures CMD1/ CMD2 to direct the Fire Message to the Auditorium Speakers or Classroom Speakers. The S5 DIP switches "5" and "6" are set to ON; these contact closures activate CMD1 (switch "5") and CMD2 (switch '6") inputs. The system may also be manually activated from the keypad. Press the Auditorium Speakers and/or Classroom Speakers button(s), then press the Fire Message button. Alternately, use the microphone to make an announcement. To manually deactivate a speaker circuit, press the activated (illuminated) output zone push-button. HOST FACP NAC JEOLR StyleZ 4.75K ohm EOLRs. PfN 75470 ~IN T.1.165 T 12341 112 3 41 112 3 41 MASTER CMU1 IN CMOS IN CMOS CMD4 CMD5 CMD OUT alarm polarities shown A NFV-25/50 Main Circuit Board Style Z supeiVisory polarity shown 151 SPEAKER TB2 BACKUP FIRST AMPLIFIER mounted on main circuit board Figure 2: Two Speaker Circuits, Dual Output Zone, Dual Input Circuit NOTE: EOLR required only for Style V (Class B). 4.751< ohm, I watt, P/N 75470. NOTE: Typical illustration of an addressable NOTIFIER control panel and addressable control modules. Refer to manual for volt- age ranges, message control switch settings, and command input specifications. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved, unauthorized Use of this document is strictly prohibited. I So 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENINLERING & MANUFACTURING All specifications are subject to change without notice. QUAlITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notitier.com Page 4 of 4— DN-7004:A1 • 1/13110 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 6911-0028:0229 Page 1 of 1 CATEGORY: 6911 -- VOICE COMMUNICATION SYSTEMS CONTROL UNITS LISTEE: NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FireVoice-25/50 and FireVoice-25/50ZS Audio Command Center. These are 25-watt audio emergency voice evacuation control panels that provide full supervision of both normal standby and alarm conditions. An optional second audio amplifier is available as a backup to the primary amplifier or to expand speaker power to 50 watts. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: FC-XRM-70 Transformer Module FC-LPS Local Playback Speakers FC-MlM Microphone Interface Module ACC-ZPMK Zone Page Module w/Keypad ACC-ZSM Zone Splitter Module ACC-AAM-25 Audio Amplifier Module RATING: Primary: 120V, 60 Hz, 1:57A Secondary: 24 V dc nominal battery voltage INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Label. APPROVAL: Listed as voice communication systems for use with separately listed compatible fire alarm control units to provide emergency voice evacuation signals. Refer to listee's Installation Instructions Manual for details. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 6911-0075:0207 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed -.. the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational c' requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires . June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division dn-6820:A1 •D-123 FDU-80 80 Character Liquid Crystal Display General The FDU-80 is a compact, cost-effective, 80 character, backlit LCD Fire Annunciator for use with the NOTIFIER FireWarden- 100-2, NFS-640, NFS2-640, and NFS-320 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and displays complete system point status information. Up to 32 FDU-80s may be connected onto the EIA-485 Terminal Mode port of each control panel. The FDU-80 requires no programming, which saves time during system commissioning. Features 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervi- sory, and Alarm Silenced. No programming necessary - FDU-80 connects to the ter- minal mode port. Displays device type identifiers, individual point alarm, trou- ble or supervisory, zone and custom alpha labels. Time and date display field. Aesthetically pleasing design. May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from host control panel. Local piezo sounder with alarm and trouble resound. Semi-flush-mounts to 2.188"/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER P/N 10103) or three- gangable electrical switchbox. Surface-mounts to NOTIFIER SBB-3 surface backbox. Operation The FDU-80 annunciator provides the FACP with point annun- ciation with full display text on an 80-character LCD display. The FDU-80 also provides an array of LEDs to indicate sys- tem status, and also includes control switches for remote con- trol of critical system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188"/5.556 cm (minimum) deep, three-gang electrical box or three-gangable electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. tj NOTIFIER by Honeywell 6820td,8 pg Agency Listings And Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 ULC Listed: CS100 MEA Listed: 245-00-E CSFM: 7120-0028:209 FM Approved Ordering Information FDU-80: 80 character, backlit, LCD Fire Annunciator with con- trol switches for remote control of system functions, and key- switch lock. 10103: Three-gang electrical box, minimum 2.188" (5.556 cm) deep, for semi-flush-mount applications. SBB-3: Three-gang surface backbox for surface-mount appli- cations. dn-6820:A1 • 02/24/09 -Page 1 012 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I So 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENCRUBING 9 MNUMCTIIRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notitier.com Page 2 of 2 - dn-6820:A1 • 02/24/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY LISTEE: DESIGN: 7120-0028:0209 Page 1 of 1 7120 --ANNUNCIATORS NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vIadimir.kireyev@honeywell.com Models FDU-80 and FDU-80G remote fire annunciators. Units are compact 80-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as annunciators for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. NOTE: Rev. 10-03-06 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria, Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division dn-6997:b • AI-320 NH-100 Series (J NOTI Fl E R' Intelligent Addressable Thermal Detectors for FireWarden Series by Honeywell Al F17' T-77 General The NOTIFIER NH-100 Series thermal detectors are address- able sensors that use a state-of-the-art thermistor sensing cir- cuit for fast response. These sensors provide open-area protection and are intended for use with the FireWarden Series (FireWarden-100-2 and FireWarden-50) addressable Fire Alarm Control Panels (FACP5). The NH-100 and NH-i OOR sensors provide fixed temperature alarm detection at 135°F (57°C). The NH-100R sensor also responds to rate-of-rise conditions of greater than 15°F (8.3°C) per minute. The NH-100H is a fixed high-temperature detector that activates at 190°F (880C). These thermal detectors pro- vide addressable property protection in a variety of applica- tions. Two LEDs on each sensor light to provide a local, visible sen- sor indication. Remote LED annunciator capability is available as an optional accessory (RA400Z). Features SLC loop: Two-wire SLC loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry of address: 01 - 99 with FireWarden- 100-2, 01 —50 with FireWarden-50. Architecture: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type identifica- tion. Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. Operation: Factory preset at 135°F (57°C) for the NH-100 and NH- 100R; 190°F (88°C) for the NH-100H. Rate-of-rise triggers at 15°F (8.3°C) per minute for the NH- 100R. 360°-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Visible LEDs blink every time the unit is addressed. Mechanicals: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ioniza- tion and thermal sensors. Other system features: Remote test feature from the panel. Walk test with address display. gill - -. 6936ph01 p NH-100 with B7IOLP base Low standby current. 94-5V plastic flammability rating. Options: Remote LED output connection to optional RA400Z remoe LED annunciator. Recessed (RMK400) or surface (SMK400E) base mount- ing kits. Installation NH-100 Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on box that is at least 1.5' (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box. 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. Single-gang box (except relay or isolator base). NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiriig "T-taps" or branches are permitted for Style 4 (Class "B") wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of off-white Bayblend®. The NH-100 Series plug-in intelligent thermal detectors are designed to commercial standards and offer an attractive appearance. Operation Each NH-100 Series detector uses one of 99 (FireWarden- 100-2) or 50 (FireWarden-50) possible addresses on a control panel SLC loop. It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. dn-6997:b • 06/08/09 - Page 1 012 The NH-100 Series offers features and performance that rep- resent the latest in thermal detector technology. Spefications Diameter: 6.1 (15.5 cm) installed in B71OLP. Height: 2.1° (5.33 cm). Weight: 4.8 oz. (137 g). Installation temperature: Nl-1-100, NH-lOOR: -4°F to 100°F (-20°C to 380C). NH-100H: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% relative humidity (noncon- densing). Voltage range: 15 to 32 VDC peak. Standby current: 300 pA @ 24 VDC (one communication every five seconds with LED blink enabled). LED current: 6.5 mA © 24 VDC. Mounting: 871 OLP flanged base, included. Fixed-temperature setpoint: 135°F (57°C) for the NH-100 and NH-1 OOR; 190°F (88°C) for the NH-1 OOH. Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. Altitude rating: 10,000 feet. Listings and Approvals Listings and approvals below apply to the NH-100 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in. process. Consult factory for latest listing status. UL Listed, file S747. CSFM approved: file 7270-0028:234. MEA approved: file 387-02-E Vol. If. FM approved. Product Line Information NH-100: Intelligent thermal sensor; 135° F (57° C) B71OLP base included. NH-100R: Same as NH-100 with rate-of-rise feature; B71OLP base included. NH-i OOH: Intelligent fixed high-temperature thermal detector; 190° F (88° C) B71OLP base included. B71OLP: Plug-in detector base (included). Dimensions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or with- out plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224R6: Plug-in System Sensor relay detector base. Diame- ter: 6.2" (15.75 cm). Mounting: 4.0' (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5' (8.89 cm) octagonal box. All mounting boxes have a mini- mum depth of 1.5" (3.81 cm). B224Bl: Plug-in System Sensor isolator detector base. Maxi- mum 25 devices between isolator bases (see DN-6994). Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16cm) square box with or without plaster ring, 4.0" (10.i6 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501BH-2: Plug-in System Sensor standard sounder base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting boxes have a mini- mum depth of 1.5" (3.81 cm). B501BHT-2: Plug-in System Sensor temporal tone sounder base. ACCESSORIES: RA400Z: Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with 8501 and B71OLP bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501 base only. RMK400: Recessed mounting kit. For use with B501 base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR28. Comes in three 5-foot (1.524 m) sections. NOTIFIER® is a registered trademark of Honeywell International Inc. Bayblend® is a registered trademark of Bayer Corp. ©2009. All rights reserved. Unauthorized use of this document is strictly prohibited. I O 9001 This document is not intended lobe used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notitier.com Page 2 of 2 - dn-6997:b • 06/08/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION MARKING: APPROVAL: XLF: 7270-0028:0234 Page 1 of 1 7270 -- HEAT DETECTOR NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com Models NH-100, (fixed temperature) and NH-100R rate-of-rise with fixed temperature heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. NH-100 135° F fixed temperature NH-100R 135° F fixed temperature and 15° F rate-of-rise In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7270-0075:0195 11-03-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not, an 21s endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division DN-7001:C .A1-380 NOT.BGI211LX(A) Addressable Manual Pull Station For FireWarden Series Panels by Honeywell r General The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels. Because the NOT-BG12LX is. addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word 'ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[131): meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on-station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: pA. The NOT-BGI2LX Addressable Manual Pull Station The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 99 on NFW2-100/NFW2-100C, 1 - 50 for NFW-50/NFW- 50C). Architectural/Engineering Specifications Temperature Range: 32°F to 120°F (0°C to 49°C) Manual Fire Alarm Stations shall be non-coded, with a key- Relative Humidity: 10% to 93% (noncondensing) operated reset lock in order that they may be tested, and so For use indoors in a dry location designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually Installation . detected as activated. Manual stations shall be constructed of The NOT-BG12LX will mount semi-flush into a single-gang, red-colored polycarbonate material with clearly visible operat- double-gang, or standard 4" (10.16 cm) square electrical outlet ing instructions provided on the cover. The word FIRE shall box, or will surface mount to the model SB-10 or SB-I/O sur- appear on the front of the stations in white letters, 1.00 inches face backbox. If the NOT-BG12LX is being semi-flush (2.54 cm) or larger. Stations shall be suitable for surface mounted, then the optional trim ring (BG12TR) may be used. mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within DN-7001:C • 09/18/2009 - Page 1 of 2 the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. NOT-BG12LXA: Canadian Dual-action addressable pull sta- tion. Includes key locking feature. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S692 (listed for Canadian and non-Canadian applications) MEA: 67-02-E Vol. IV CSFM: 7150-0028:199 FM Approved Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. Notifier® is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. I so ooi This document is not intended lobe used for installation purposes. We try to keep our product information up-to-date and accurate. '- 1 G dl ] We cannot cover all specific applications or anticipate all requirements. Z-3 74: ENSINEERINC & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the L)S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 012— DN-7001 :C • 09/18/2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevhoneywetl.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-12-LO, NBG-12LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBG-12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG-12SP, NOT-BG12LX, NBG-12LXSP, NBG12LXBL* and NBG12LXP* fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listée's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12L0, NBG-12LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. *These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. Rev. 04-08-10 bh I: This listing is based upon technical the test results and/or other data but / endorsement or recommendation of requirements or installation criteria. information sources. Date Issued: July 01, 2010 data submitted by the applicant. CSFM Fire Engineering staff has reviewed does not make an independent verification of any claims. This listing is not an the item listed. This listing should not be used to verify correct operational Refer to listee's data sheet, installation instructions and/or other suitable Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division NP-100(A), NP-I OOT(A), NP-1 OOR(A) Addressable Photoelectric Detectors for the FireWarden Series General The NP-100 and NP-100T addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's Fire War- den Series (FireWarden-100-2 and FireWarden-50) Address- able Fire Alarm Control Panels (FACP5). The NP-100T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a tire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annun- ciator capability is available as an optional accessory (P/N RA100Z(A)). The NP-100R is a remote test capable detector for use with DNR(W) duct smoke detector housings. Features SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry of address: 01 - 99 with FireWarden- 100-2, and 01 —50 with FireWarden-50. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED 'blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5' (8.89 cm) or 4.0' (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA100Z). dn-6995:b • A1-320 ~n_j NOTIFIER" NP-100 with B710LP base NP-100T with B710LP base Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white LEXAN®. NP-100(T) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation NP-100(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring. 4.0" (10.16 cm) octagonal box. 3.5" (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. .Wiring 'T-taps" or branches are permitted for Style 4 (Class B) wiring. NP-lOOP mounts in a ONR(W) duct detector housing. dn-6995:b • 3/12/10 - Page 1 012 Operation Each NP-1001T/R uses one of 99 possible addresses on the FireWarden-100-2 and one of 50 possible addresses on the FireWarden-50 Signaling Line Circuit (SLC). ;t responds to regular polls from the system and reports its type and status. The NP-1001T/R addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) without sending an alarm level signal. Because of its unipolar chamber, the NP-bOlT/fR is approximately two times more responsive than most photo- electric sensors. This makes it a more stable detector. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a FireWarden-100-2 or FireWar- den-SO addressable fire alarm control panel. The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire- Warden-50 for record keeping. Specification Voltage range: 15-32 VDC (peak). Standby current: 300 pA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Diameter: 6.1' (15.5 cm) installed in B71OLP base. Height: 2.1' (5.33 cm) installed in B71OLP base. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100: 0°C to 49°C (32°F to 120°F); for NP-lOOT: 0°C to 38°C (32°F to 100°F). NP-IOOR: installed in a DNR(W) -20°C to 70°C (-4°F to 158°F). Temperature: 0°C-49°C (32°F- 120°F). Relative humidity: 10% - 93%, non-condensing. Listings Listings and approvals below apply to the NP-100 and NP- 100T detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed, file Si 115. CSFM approved: file 7272-0028:231. MEA approved: file 243-02-E Vol. 2. Maryland State Fire Marshal: permit 2173. FM approved. Product Line Information NP-100: Adressable photoelectric detector; 871 OLP base included. NP-100A: Sames as NP-100 with ULC Listing (B71OLPA base included). NP-lOOT: Same as NP-100 but with thermal element; B71OLP base included. NP-100TA: Same as NP-100T with ULC Listing (B710LPAbase included). NP-100R: Remote test capable addressable photoelectric detector for use with a DNR(W) duct detector housing. B71OLP: Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB: Plug-in System Sensor relay detector base. Diame- ter: 6.2" (15.75 cm). Mounting: 4.0' (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a mini- mum depth of 1.5 (3.81 cm). B224B1: Plug-in System Sensor isolator detector base. Maxi- mum 25 devices between isolator bases (see DN-6994). Diameter: 6.2° (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B200SR: Sounder base capable of producing temporal-3 or steady sound output. ACCESSORIES: RAlOOZ(A): Remote LED annunciator. 3- 32 VDC. Mounts to a U.S. single-gang electrical box. For use with 6501 and B7JOLP bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with 6501 base only. RMK400: Recessed mounting kit. For use with B501 base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR28. Comes in three 5-foot (1.524 m) sections. T55-1 27-010: Detector removal tool without pole. BCK-200B: Black detector covers, box of 10. WCK-200B: White detector covers, box of 10. NOTIFIER® is a registered trademark of Honeywell International Inc. Baybtend® is a registered trademark of Bayer Corporation. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I O 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MNUfAC11JRINC All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notitier.com Page 2o12- dn-6995:b • 3/12/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:0231 Page 1 of 1 CATEGORY: 7272 -- PHOTOELECTRIC SMOKE DETECTOR LISTEE: NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevlhoneywell.com DESIGN: Models NP-100, NP100R* and NP-100T photoelectric type smoke detectors. Model NP-100T has a 1350F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0 - 4000 FPM. *Models NP-100 and NP-100R are also approved for installations inside Notifier duct detector housing ND-200 (OSFM Listing No. 3242-0028:236) and System Sensor duct detector housing DNRW (OSFM Listing No. 3242-1653:210). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0075:0194 *Rev. 01 -27-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ''"\ the test results and/or other data but does not .make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division dn-6999:bl Monitor Modules NMM.100(A), NMM.IOOP(A), NZM. 100(A). and NDM-100(A) for FireWarden Series Panels by Honeywell General Four different monitor modules are available for Notifiers Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4" [10,16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3 (3.302 cm) H x 2.75" (6.985 cm) W x 0.5 (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. lts.compact design allows the NMM-100P(A) to often be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. NMM-100(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 —50 on Fire Warden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM- 100(A) A PPLICA TIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. NMM-100(A) (Type H) NMM-1 00(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NMM-IOOP(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 —50 on FireWarden-50. dn-6999:bl .11/19/09—Page 1014 10 14 15 01 ADDRESS .9,1 13 :''2 12 .: .3 11 LOOP V'; 4 10 . 8 76 L 6 TENS ONES Ui 0 -, Li I. The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. NMM-100P(A) NMM- IOOP(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. NMM-100P(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). NMM- 100P(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. NZM.100(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address:, 01 - 99 on FireWarden- 100-2, 01 —50 on Fire Warden-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM- 100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NDM-100(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact tire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM- 100(A) provides two Style B (Class B) lOG cir- cuits ONLY Style 0 (Class A) lOG circuits are NOT supported in any application. NDM- 100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Page 2o14— dn-6999:bl • 11/19/09 Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x 2.125" (5.398 cm) deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address '26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: 'Ones" addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125° (5.398 cm) deep, electrical box. They may also be mounted to the SMBSOO surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 FM Approved CSFM: 7300-0028:230 (NMM-100, NMM-100P, NZM-100); 7300-0028:237 (NDM-1 00) MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100): 227-03-E Vol. 3 (NDM-100) Product Line Information NOTE: "A"or suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM-100P(A): Monitor module, miniature. NZM-100(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. dn-6999:bl • 11/19/09 - Page 3 of 4 Notifier® and FireWarden® are registered trademarks and FireWatchTM is a trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. . We cannot cover all specific applications or anticipate all requirements. ENGINIERING g MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Maaern the U.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— dn-6999:bl • 11/19/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION MARKING: APPROVAL: XLF: 7300-0028:0230 Page 1 of 1 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. 15-32 VDC In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and .UL label. Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 7300-0075:0185 10-20-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed '\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division dn-60383:A2 NC-IOOR(A) NOTFER Relay Module for FireWarden Series Panels by Honeywell General The NC-i OOR(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- tact to be activated, either manually or through panel programming, on a select basis. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED blinks" green each time a communication is received from the control panel and turns on in steady when activated. High noise immunity (EMF/RFl). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct Decade entry of address: 01 - 99 with the FireWar- den-100-2(C) and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The NC-100R(A) provides two Form-C dry contacts that switch together. Operation Each NC-100R(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status. The LED blinks with each poll received. On command, it activates its internal relay. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel. NC-i OOR(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (UR=5m5) Coded 30 VDC 0.5 A Inductive (UR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2 • 06/17/10 -Page 1 012 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL/ULC Listed: S635. CSFM approved: file 7300-0028:230. FM approved. MEA approved: file 72-01-E, Vol. 2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module, ULC listed model. SM B500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual, document 52304. NOTIFIER® is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. I so ooi This document is not intendd lobe used for installation purposes. We try 10 keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINIERING 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notitier.com Page 2 of 2 - dn-60383:A2 • 06/17/10 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of 1 CATEGORY: 7300 -- MISC. DEVICE/CONTROL UNIT ACCESSORIES LISTEE: NOTIFIER, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listees separately listed electrically compatible fire alarm control units. Refer to listees Installation Instruction Manual for details. XLF: 7300-0075:0185 10-20-04 , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed .. the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational c7 requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division COOPER Notification EOCE20~_ Finally, Design and Safety Meet... I - . I Ceiling Description: The Wheelock® ExcederTIA Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The WheelockO ExcederTIA Series incorporates high reliability and high efficiency optics to minimize current draw allowing fora greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. - Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of installation** Sleek Modern Aesthetics W. Finger Slide Switches Voltage Test Points Multiple Voltages Nu U 3 Audible Settings 90, 95, 99 dB U 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75/95/115/1 C0/177 Universal Mounting Base Ceiling and Wall Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw Compatibility and Requirements - Synchronize using the Wheelock® Sync Modules or panels with built-in Wheelock® Patented Sync Protocol - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range Compared to competitive models Patented Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICA11ON.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Horn Strobe Ratings per UL 1971 & UL 464 at 24 VDC 24 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 7.282 T25 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 ,""' 0.242 HSC 80330 0.082 0102 0.141 0.148 0.176 ( 0.197 n 0.242 UL Max c6rrai-at 95 dBA' 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 I 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 -°° 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 80330 0.073 0087 0128 0.139 0.163 '- 0.186 0230 0272 0.122 • ••••• 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 °. 0.136 0.157 0.184 , 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 -Yi,' 0.184 0.226 0.267 ,. ., 0.120 Horn Ratings per UL 464 Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information - Sync w/SM, Model Strobe b DSM or 12/24 VDC' Mounting Candela Options - I PS-6 & PS-8 -..----- - -. SR 15/1575/30175/95/110/135/165 X X -- UMB HSW 15/1575/30175195/110/135/185 X X UMB* t.) J HSRC 15/30/60/75/95/115/150/177 X X UMB** HSWC 15/30/60/75/95/115/150/177 X X UMB STR 15/1575/30/75/95/110/135/165 X X UMB SIW 15/1575/30175195/110/1351185 X X UMB* STRC 15/30160/75195/1151150/177 X X UMB* STWC 15/30/60/75/95/115/150/177 X X UMB** HNR X X UMB** HNW X X UMB** HNRC X X UMB* .11 HNWC X X UMB** *12VDC models feature 15 & 15/75 settings **UMB = Universal Mounting Base NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be V\/heelock® ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective. Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6' D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s SM, DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC LNEIVA WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 11/09 Cooper Notification is Wheelock* (MEDCJ SAFEPATH WAV COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0168 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc. 273 Branchport Ave, Long Branch, NJ 07740 Contact: Lyn Sorrentino (732) 962-7832 Fax (732) 962-7856 Email: lyn.sorrentino@cooperindustries.com DESIGN: Exceder Series: Models ST strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a'-NR' may be added for non-resettable models. For nn -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135& 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ,.•. the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation, criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2010 Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division COOPER Notification Series E70 Speakers and Speaker Strobes SERIES E70 STROBE FI RE d4 - SERIES E90 STROBE SERIES E70 SPEAKER SERIES E90 SPEAKER Description The Wheelock Series E Low Profile Speakers and Speaker Strobes are designed for high efficiency sound output, with dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 2 watts. The low profile design incorporates a speaker mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic two (2) screw grille cover. The Series E Speaker Strobe models incorporate the Low Current draw Series RSS Strobes. Strobe options for wall mount models include 1575 or Wheelock patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models are available in Wheelock patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. Series E Speakers and Speaker Strobes provide high audio output with clear audibility and are designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. The strobe portion of all Series E Speaker Strobes may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. Series E Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing-Impaired) and Standard 1480 (Speaker Appliances), and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan® lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using #12 to #18AWG wiring. Color options for the Series E Speakers and Speaker Strobes are red, white and nickel plated. 0 <S> MEA APPROVED S5391 15-92.E 7125-0785:52 7320-0785 134 (Speaker) Features Approvals include: UL Standard 1971, UL Standard 1480, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPA/ANSI compliant Complies with OSHA 29 Part 1910.165 Wall mount models are available with Field Selectable Candela Settings of 15130/75/11Ocd or 135/185cd (Multi- Candela models), or 1575cd (Single Candela model) Ceiling mount models are available with field selectable candela settings of 15130/75195cd or 115/177cd (Multi- candela models) Strobes produce 1 flash per second over the regulated voltage range 24 VDC with wide UL "Regulated Voltage" using filtered DC or unfiltered VRMS :nput voltage Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol Field selectable taps for 25 0170 VRMS operation from 1/8 watt up to 2 watts High efficiency design for maximum output at minimum wattage across a frequency range of 400 to 4000 HZ Fast installation with IN/OUT screw terminals using #12 to #18AWG wires NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range". Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: UL Max Current* E70 Strobe Current - Wall Mount E90 Strobe Current - Ceiling Mount E70/E90 Speaker 241575W 24MCW 24MCWH 24MCC 24MCCH Strobes 1575cd 15cd 30cd 75cd 110cd 135cd 185cd l5cd 30cd 75cd 95cd 115cd 177cd 16-33 VDC 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 Table 2: E70/E90 UL Reverberant dBA @ 10 Feet** watts 1/8 1/4 1/2 1 2 E Speaker 77 81 83 86 89 E Speaker Strobe 76 80 82 85 88 "dBA ratings are based on testing under UL Standard 1480 * UL max current rating is the maximum RMS current within the listed Voltage range (16-33V for 24V Units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Wiring Diagram? SERIES E SPEAKER & STROBE OPERATE SERIES E SPEAKER STROBES SYNCHRONIZED INDEPENDENTLY (NON-SYNC OR SYNC) WITH MULTIPLE DSM MODULES role ________ Oudble NAC i QSM 01 Note: Figure PRECEDIN + +NEXT APPLIANCE 1 shows intercon EVACUATion - PAN 1. I I I A AU .fSJLNAcPSM! through sync + -. — ir — — — -1-1+1- - - 3TnA9flvnsI JJ module. Speaker CPU' C portion requires 2 EOLR STP000 SPEAKER DUll Interconnecting wiring shown. Maximum of twenty (20) SERIES E SPEAKER STROBE APPLIANCES SERIES E SPEAKER STROBE APPLIANCES & RSS SYNCHRONIZED WITH DSM MODULE SINGLE STROBES SYNCHRONIZED WITH PS-12/24-8CP and CLASS "A" PS-I 2/24-8MP0 DSM en s-ii-sep.. STROBE NAC SYNC CIRCUIT OUTPUTS EOLR OUT ® ,OUT I -n 4-CLASS, NUS I OR E ass 2-CLASS: m2 _AVDIBLC A 0M1005 2 O + IN ROBE 0 NAC ' COT 2. CIRCUIT' Series P5-12/24-8 B El U RaY For wiring information on the PS-24-8MC power supply, please refer to Data Sheet #S8900. 11 For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84662. Specifications and Ordering Information Model Order Code Wall Mount Ceiling Mount Strobe Sync w/ SM, DSM or PS-24-BMC Strobe Candela Model Color RED Model Color White Model Color Nickel Mounting Agency Op- tions Approvals — — UL 7MEAFM FM BFP E70-24MCW-FR 9022 X - X 15/30/75/110 X - - LO,P,Q,R,U,Y X X X X X E70-24MCW-FW 9023 X - X 15/30/75/110 - X - L,O+PQ,R,U,Y X X X X X E70-24MCW-FN 3099 X - X 15/30/75/110 - - X j QU X X X X X E70-241575W-FR 7871 X - X 15 (75 on Axis) X - - L,O,P,Q,R,U,Y X X X X X E70-241575W-FW 7876 X - X 15 (75 on Axis) - X - LO+PQ,R,U,Y X X X X X E70-241575W-FN 3100 X - X 15(75onAxis) - - X L,O,P,Q,R,U,Y X X X X X E70-R 7866 X X - - X - - Q,U X X X X X E70-W 7866 X X - - - X - Q.0 X X X X X E70-N 3108 X X - - - - X Q,U X X X X X E70-24MCC-FW 0102 X X 115/177 - X - Q,U,V X X X X X E70-24MCWH-FR 3470 X - X 135/185 X - - LOP,Q,R,U,Y X X X X * E70-24MCWH-FW 3474 X - X 135/185 - X - L,O,P,Q,R,U,Y X X X X E70-24MCWH-FN 0059 X - X 135/185 - - X au X X X X * E90-24MCC-FW 3166 - X X 15/30/75/95 - X - Q,U,V X X X X E90-24MCC-FR 3165 - X X 15/30/75/95 X - - Q,U,V X X X X E90-24MCC-FN 3185 - X X 15/30/75/95 - - X Q,U,V X X X X * E90-W 7869 X X - - X - Q,U,V X X X X X E90-R 7867 X X - . - X - - Q,U,V X X X X X E90-N 3109 X X - - - - X Q,U,V X X X X X E90-24MCCH-FW 3471 - X X 115/177 - X - Q,U,V X X X X * E90-24MCCH-FR 3481 - X X 115/177 X - - Q,U,V X X X X E90-24MCCH-FN 0062 - X X 115/177 - - X Q,U,V X X X X I Also comes in NW (no writting). Models available with no writting, may be subject to minimum quantity order. *PENDING Architects and Engineers Specifications The speaker appliances shall be Wheelock Series E Speakers and the speaker strobe appliances shall be Wheelock Series E Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices for the Hearing-Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The strobe shall be of low current design. Where Multi-Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock SM, DSM sync modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series E speakers and strobe speakers shall be white, red, or nickel plate. All speaker and speaker strobe appliances shall be backward compatible. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY S1610 E70/E90 07/10 Cooper Notification is Wheelock* (MEDcJ SAFEPATH WAV 7) COOPER Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:0152 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc., 273 Branchport Ave, Long Branch, NJ 07740 Contact: Lyn Sorrentino (732) 962-7832 Fax (732) 962-7856 Email: Iyn.sorrentino@cooperindustries.com DESIGN: Models *ET70241575w ET70-24MCW, ET70-24MCC, ET70-24MCWH, ET70-24MCCH, *ET80..24 1575W, ET80-24MCW, ET80-24MCWH *ET9024 1575W, ET90-24MCW, ET90-24MCC, ET90-24MCWH, ET90-24MCCH, E70-24MCW, E70-24MCC, E70-24MCWH, E70-24MCCH, E90-24MCW, E90-24MCC, E90-24MCWH, and E90-24MCCH multi-candela speaker/strobes. Models E60-R, E60-W, E60-24MCC-FW, E60-24MCCH-FR, E60-24MCCH-FW, E60EXT-R and E60-EXT-W multi-candela speaker/strobes. May be followed by suffixes to designate lens lettering and plate color. *Lens color may be Clear, Red (R), Blue (B), Green (G), or Amber (A). EXT is an extender ring that mounts behind the speaker. Intended for indoor use only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC, 25/70 VRMS Flash rate: 60 flashes/mm Candela: MCW =15cd,30cd,75cd or 110cd MCC =l5cd,3Ocd,75cd or 95cd MCWH = 135cd,185cd MCCH = 115cd,177cd *1575 = 15 cd/75cd on axis INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Models followed by W or WH are wall mounts; C or CH are ceiling mounts. All models are for indoor use. MARKING: Listee's name, model number, electrical and candela rating, and UL label. APPROVAL: Listed as strobe speakers suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM-12/24 or DSM-12/24 synchronized control modules (CSFM Listing No. 7300-0785:132) must be used. Refer to manufacturer's Installation Manual for details. NOTE: These units do not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. *Rev. 07-30-10 fm S This listing is based upon technical the test results and/or other data but / endorsement or recommendation of requirements or installation criteria. information sources. Date Issued: August 04, 2010 data submitted by the applicant. CSFM Fire Engineering staff has reviewed does not make an independent verification of any claims. This listing is not an the item listed. This listing should not be used to verify correct operational Refer to listee's data sheet, installation instructions and/or other suitable Listing Expires June 30, 2011 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-33 FIRE ALARM SYSTEM RECORD OF COMPLETION To be completed by the system Installation contractor at the time of system acceptance and approval. PROTECTED PROPERTY INFORMATION Name of property: St. Elizabeth Seton Address: 6628 Santa Isabel St - Carlsbad, CA 92009 Description of property: Church Occupancy type: V-A Name of property representative: - Address: Phone: Fax: E-mail: Authority having jurisdiction over this property: Phone: Fax: E-mail: FIRE ALARM SYSTEM INSTALLATION, SERVICE, AND TESTING INFORMATION Installation contractor for this equipment: JJJ Enterprises Address: 533 So. Vinewood Escondido, CA Phone:-(760) 747-3050 Fax:(760)747-7561 E-mail: Service organization for this equipment: Same Address: 533 So. Vinewood Escondido, CA 92029 Phone: (760)747-3050 Fax: E-mail: Location of as-built drawings: Location of historical test reports: Location of system operation and maintenance manuals: A contract for test and inspection in accordance with NFPA standards is in effect as of Contracted testing company:JJJ Enterprises Address: 533 So. Vinewood Escondido, CA 92029 Phone: (760)7473050 Fax:(760)747305 E-mail: Contract expires: Contract number: Frequency of routine inspections: Qtr TYPE OF FIRE ALARM SYSTEM OR SERVICE NFPA 72 Chapter Reference of System Type: Chapter 8 Remote Supervising station Name of organization receiving alarm signals with phone numbers (if applicable): Alarm:GMS Phone: (866) 789-1175 Supervisory: _GMS Phone: (866) 789-1175 Trouble: GMS Phone:(866)789-1175 Entity to which alarms are retransmitted: Phone: Method of retransmission of alarms to that organization or location: 2007 National Fire Protection Association NFPA 72(p. lot 5) FIGURE 4.5.2.1 Record of Completion. 2007 Edition 72-34 NATIONAL FIRE ALARM CODE TYPE OF FIRE ALARM SYSTEM OR SERVICE (continued) If Chapter 8, note the means of transmission from the protected premises to the central station: Digital alarm communicator U McCulloh 3 Multiplex 0 2-way radio 0 1-way radio U N/A If Chapter 9, note the type of connection: 0 Local energy U Shunt U N/A 3.1 System Software Operating system (executive) software revision level: Rev. 3 Site-specific software revision date: Revision completed by: SIGNALING LINE CIRCUITS Characteristics of signaling line circuits connected to this system see NFPA. 72, Table 6.6.1): Quantity: 1 Style: _4 Class: B S. ALARM-INITIATING DEVICES AND CIRCUITS Characteristics of initiating device circuits connected to this system (see NFPA 72, Table 6.5): Quantity: Style: Class: 5.1 Manual Initiating Devices 5.1.1 Manual Pull Stations Number of manual pull stations: 1 Type of devices: N Addressable 0 Conventional CI Coded 0 Transmitter U N/A 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Number of smoke detectors: _7 Type of coverage: U Complete area M Partial area 0 Nonrequired partial area 0 N/A Type of devices: 'i Addressable U Conventional U Coded U Transmitter U N/A Type of smoke detector sensing technology: U Ionization 0 Photoelectric 5.2.2 Duet Smoke Detectors Number of duct smoke detectors: 17 Type of coverage: HVAC units and SFD' s Type of devices: M Addressable U Conventional LI Coded LI Transmitter U N/A Type of smoke detector sensing technology: 0 Ionization U Photoelectric 5.2.3 Heat Detectors Number of heat detectors: 2 Type of coverage: U Complete area Xi Partial area U Nonrequired partial area 0 N/A Type of devices: Addressable U Conventional U Coded U Transmitter 0 N/A 6.2.4 Sprinkler Waterfiow Detectors Number of waterfiow detectors: 1 Type of devices 10 Addressable 0 Conventional 0 Coded U Transmitter 3 N/A 5.2.5 Alarm Verification Number of devices subject to alarm verification: Alarm verification on this system is: U Enabled XI Disabled Ci Set for _______ seconds © 2007 National Fire Protection Association NFPA 72(p.2 of 5) FIGURE 4.5.2.1 Continued 2007 Edition FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-35 SUPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUITS 6.1 Sprinkler System Number of valve supervisory switches:4 Typo of devices: M Addressable 3 Conventional 13 Coded 13 Transmitter 3 N/A 6.2 Fire Pump Type of fire pump: 0 Electric 0 Diesel Type of fire pump supervisory devices: 0 Addressable Ci Conventional Ci Coded U Transmitter U N/A Fire Pump Functions Supervised O Fire pump power 13 Fire pump running 0 Fire pump phase reversal 0 Selector switch not in auto Ci Engine or control panel trouble Ci Low fuel Other 6.3 Engine-Driven Generator Type of generator supervisory devices: Ci Addressable 13 Conventional 13 Coded Ci Transmitter Ci N/A U Engine or control panel trouble U Generator running U Selector switch not in auto U Low fuel Other: ANNUNCIATORS 7.1 Annunciator 1 13 Local 4 Remote Type: 0 Addressable CI Directory 0 Graphic Ci N/A Location: 1st Fl Lobby 7.2 Annunciator 2 Ci Local Ci Remote Type: U Addressable 0 Directory 0 Graphic 3 N/A Location: 7.3 Annunciator 3 Ci Local U Remote Type: 0 Addressable U Directory U Graphic 0 N/A Location: B. ALARM NOTIFICATION DEVICES AND CIRCUITS 8.1 Emergency Voice Alarm Service Number of single voice alarm channels: 1 Number of multiple voice alarm channels: Number of speakers: 26 Number of speaker zones: 2 8.2 Telephone Jacks Number of telephone jacks installed: 0 Number of telephone handsets stored on site: Type of telephone system installed: 13 Electrically powered 0 Sound powered Ci N/A 8.3 Nonvolce Audible System Characteristics of notification device circuits connected to this system (sea NFPA 72 Table 64): Quantity: 0 Style:_ Class:- 0 2007 National Fire Protection Association NFPA 72(p.30t5) FIGURE 4.5.2,1 Continued 2007 Edition 72-36 NATIONAL FIRE ALARM CODE ALARM NOTIFICATION DEVICES AND CIRCUITS (continued) 6.4 Types and Quantities of Nonvolce Notification Appliances Installed Bells: With visual device: Horns: With visual device: Chimes: With visual device: Bells: With visual device: Visual devices without audible devices: 8 Other (describe): EMERGENCY CONTROL FUNCTIONS ACTIVATED IM Hold-open door releasing devices 0 Smoke management or smoke control 0 Door unlocking Elevator recall 0 Other SYSTEM POWER SUPPLY 10.1 Primary Power Nominal voltage 120vac Amps Overcurrent protection: Type brkr Amps 20 Location (of primary supply panelboard): PNL 12J-20 Disconnecting means location: brkr 10.2 Secondary Power Location- FACP Type: AGM Nominal voltage: 12vdc Current rating:_8 - Number of standby batteries: 2 Amp hour rating: 12 Location of emergency generator: Location of fuel storage: Calculated capacity of secondary power to drive the system In standby mode: 24 hours In alarm mode: 15 mm RECORD OF SYSTEM INSTALLATION Fill out after all installation 13 complete and wiring has been checked for opens, 8h0rt8, ground faults, and improper branching, but before conducting operational acceptance tests. The system has been installed in accordance with the following NFPA standards: (Note any or all that apply.) NFPA 72 M NFPA 70, National Electrical Code, Article 760 Manufacturer's published instructions 0 Other (please specify): System. deviations from refere ced NFPA standards: Signed: Printed name: Jim McKinley__ Date: 8/23/2 011 Organizn: Ent Title:prOjeCt Mgr Phone:607473050 12. RECORD OF SYSTEM OPERATION All operational features and functions of this system were tested by or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements of: NFPA 72 3 NFPA 70, National Electrical Code, Article 760 12 Manufacturer's published insuctions 0 Other (please specify): U Dojientlrtttn in accord qjd'with Inspection and Testing Form (Figure 10.6.2.3) is attached Sign —/' 1-) Printed name: Jim McKin1eX_ Date: 8/23/2011 Organia.h: JJJ Ent 'Fitle: Project Mqr Phone:76°747 3050 © 2007 National Fire Protection Association NFPA 72(p. 4o1 5) FiGURE 4.5.2.1 Continued 2007 Edition 11 FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-37 13. CERTIFICATIONS AND APPROVALS 13.1 System Installation Contractor This system as specified herelin ias been installed and tested according to all NFPA standards cited herein. SignCT )7 W-Z--T Printedname: Jim McKinley Date: 8/23/2011 Organize. Ent Tjtle:roj Mgr Phone: (767) 7473 050 13.2 System Service Contractor This aye specified herein as been installed and tested according to all NFPA standards cited herein. Signe ___________________ Printedname: Jim McKinley Date: 8/23/2011 Organize ion:JJJ Ent Title: Proj Mgr Phone: (767)747-3050 13.3 Central Station This system as specified herein 1 be monitored according to all NFPA standards cited herein. Signed. - Printed name: Jim McKnley Date: 2/23/2 011 Organizatio Ent - Title: Proj Mgr Phone: (767) 747-3050 13.4 Property Representative I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Printed name: Peter J. Kruse Date: 2/23/2011 Sig services Title: S tU'eDW1 4'A Phone: 7608452400 Orga ation: _______________________________ 13.5 Authority Having Jurisdiction I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications, its approved sequence of operations, and with all NFPA standards ted herein. Signed _ Printednam 4d Tit Phone: Organizatio 2007 National Fire Protection Association NFPA 72(p.5o15) FIGURE 4.5.2.1 Continued 2007 Edition AS BUILT Q8124/1 1 OPIE 000051 FA1 OF 6 P. ST. ELIZABETH SETON CATHOLIC CHURCH 6628 SANTA ISABEL STREET, CARLSBAD CA, 92009 FIRE ALARM SYSTEM GEL NOTES BUILDING DATA SCOPE OF WORK DEVICE LEGEND . .. - liP. FPS U.,, Sot 100.,, 10 P510 fl 1010PM. in sot via apot II 2€ Scoct tE10BC PUCM! UP. flPiB AS BPS R 5-I com CS0P 110 9151523 943.1 11 94700 P40 40KB P.0W BaPIOC RPM. 1015011 10t-PBa F M CPPITB01J 1515011 101 1015. I Ma 1011 0P-24 194G CaST LOP 9511, LIP. 1B Atoll 5501 - 100101 to M** 710 CIa. CAStoW. OBI CS.. , at *.coomcINIm ----------------------------- SvBi a. na 51,1KB 15SS Pal PE G *094*15 1005194 RDU 0-4 tHUS NO Still in. ILL P0(TS 10 MOlt AS SUIt IN 110 i BE (.0750 tV-flP.Cfl OMIT. 1, 10750 Bat 10110. alto Ca'sPM' .1 10 1 at V. lb. at.,, es,. a v== "1,11 FII 54510- P.. .,5MI0-10, Nan M __T CE) LIST LM 10910.to CI .50MB,, Sd to By V 101.10 vS 910. to B. PB. 104010 ato__ __9211 S.F. 10101000 IC 11017. SlOOP P10W 0P0 9415 T23PiTPBPl3. 10011123 1010& ML ____- 10710 MB-Pa. nPIDiUIBT Bat 111* OMLSU1 100594 ft P.O MIII 0Mb P.O - .070 ._, 1111*1010 P.4015101W. svt.v, _6'a *5 .a LOT gm 04 'CoRu U. 11 010 l-XT S 10710100. .BPBa.LOOI ..!!_ - -_ B PD I 010l10laP00Wft7I0P am 1035 7110- 230 OMaa.0 1401 0. 5, vd 10. US, 'd s a. tImI 01*10111 LA0P_.P137 01051010 1101 U. - PP 1=lX OP=vB, 015L 14011310015145011 LIBT SOT 061901 - sma 15P0 2*Ssp.UIz 45010 p10w B a4010US10:W.a .94 NEWMO_ill in01/P401___10 - PaTIO IC-lOP I 1114t0._ Pm, o.m. at y. FOP vat Ivat atatt a. aa.a04 By *. 10 AN 007051475 9407 2OP Clb........__________...IlT ________________________- _.. I IMOBMilO €131 01110 ' APPLICABLE STANDARDS - ABBRETIONS SEE - IC. bNa - n .ccm WOO?. 7125-OMIU so P10PIBMU.al0avdA% 4594 40P II. 2== 0101101101 *1 501St 110$ 60111100 P.01 B @1 01_iI 7101.0110152 oat t_i.TI" I _J tom. pana 9. 01 1005 101(0194 II voollP4*7 (YB. 610717 p0.5 to ..110. 94. . II 40 40172.0101794 POOR Its PIMI 01 -- ------..-------------- -----1--- .-----------------.--------------Rt10005&B07ULOITCTWO b, m APPLICABLE CODES CENTRAL STATION INF0RMATlONL [ (MO - 40119 10.01045 III i8l6 1115 65 _ioa., to - Adwlftb~ c_ rto01 70.09 CI 30 - ------------- g. -4- 10 11 5061 41119 10101 511101 4J_Jr15tl50 L :T 1110 1101 Sd to 10BP 0711.110.4 10 .a *70 0111 Iv USd11451,, S ANd.. 11004117 40 .o01,y - -07 UIWa 1109 (101,0 P. 014 2. 0060* HUSalOM 715,2.100101) 510011 10 d (015) 157-1119 SW.. OW BPU.I17 1.4.1511 to .410 4.. 9 550 w.6I*. 0.. P1.45 at .017 01114. 0USd CU. U50*) 110 7110 151045 494 (*123 Iv 515 o45 45 100110 IO-W.US Ola 10 a. 4.. .a , - _ mm ScWLW 10.1 Cvn US - - am P5 I B - B ttPllL 4.d11Sd 0.0 01010 I7•51lt POlO 0 50 11011 1,lI 401011 -07 01.T10ts17109 01 40 1110101.94 10510400111 010101105001 10 P101940111 ots '" ----- - -- r- - .çoat. v..1.p4l9tUSdaa.11011 B5.d...5.0b.USa.0,ol.,,USU US -079410115. II 10/211,11 SC 0 9 J 3 11511,1 .l145° .11000 40 to P.. 154 lId 9. 79. PIp __ 115 mopoC p010 15 115 21-1949 101115115 01103 Fc SIllS. P 011 P0107 - a Il/P 17115 I #10 7 P IWE - 21055.114101 .4511005 104Mb ad.. b,,çv .4594 00• a. o, to Ill I'. 40.11 - - 017 WWI. K PtACED IN THE 50 GF IKE mffl. OR IFOPT TO 1741 P051 01 715 94,.. 3400. 010,1 10Mb '*40 01 .• (i.- p043 0150 a -07 941001 CU. WALL. ------ --- -----------------CONDUIt SIZE - ,D11dP. *5.4S.aUS *.d5iBy b40g p014.410.440. (P15*119.21. ) - -. - 1511 26 3.01 01110117,04 Ml 1*5100000 dO 117.2. CI B. in 11 151 Sd 10 . OP 01001 501 10011011 US sp CMU.AIOI 111500017910 -01 1 16_L/ (PIol 7.59.0.230 - - I 17 J15) 1911Kwp 10000.6100000107 P.L AL .7 . It-.Ir'r- (.7C t.7flCDaTIt\KIC (Pop Ii 110 II. cUCcT IMñEV - VICINITY MAP SYSIDI LIMIT ~ n" II4i ! p '9 I - 1 • CO-S 007150405 Co-a 51,7011010115 0105.UI - --- - - J11L!• "1 I" P P P 1 Li. Arlp EMTERMSES ciomm 9960 2331011743.151121501. ESCOM OP 52015 (700) 741-07 011t3 (763) 741-1361 P01.11 DESERT 9560 79-279 LNO SB. 9.111 C PALM 01141, Co 92211 (750) 360-7949 COOP (363) 210-2947 FIRE *35 1521517 • LOW MAX 215100 clop B ((0060 1 5&2169 NOTIPIIW 0101001110 600Z6'YOOV9S1eJV3 -- 1.3W.S13YSV1NVS9Z99 CN I HHI ama mi %~ 2. P lill NO.L3SHi28VZI13.LS r th I . i j Is a 14 _:.............. ;r r -r I will 11 I 1 I$jilljjjLij a a •V9WO&LSaL ..,eO:L Ls,ec:t. tlOa Sr oflwCfllA> asludaassa err nou look - 600Z6 'V3 OV2S1VO 1331S 1VSI VINVS 9Z99 HOIflH3 OflOHiVZ) I j I I ki U.. I I j N0I3SH.L38VZfl3.LS to m S S sSve4. LSa.L •.,Se :4. .LS.'•C it I LOS QS oflw(fll-4.t) mS IuaanNS rrr 14005 !E 5 F 'K bOOZ6 •VD aV9S1YO .I33IS 138VSI YINVS 999 — I-1OiflH33flOH1V3 N013SH199VZI11S 2 — (0 H • i b ' all -a pa A :o — —all to fl I a ! a e) go ! a VillC11 L Al a a $ EiE - to 11 .; fp- 11 l 4!' 4l-1 16i g PU1 q j • • I I C-' z lip I88HjI8I81 oil li-hoi; ul __________________ LU_L.I. - •y.-' 12 - - 1! L Lj U ! ii Hjt : .J_ tH p !I 11 ' I I - 1p I I :L ::I :EL. 01 a •0Q0LLZL 0n100:4 ssto:A. LI0Z 0 0flW(flNS) OSSUdUOSHO err ,.oua I 60OZ6V3GVS1V3 [1 (0 go — 'J1S 1]9VS1 VINVS 9Z99 g ,, u.0 I HOflH9 3I1OHJ.VO pr I f NO.LS H1VZI1 IS all L rp -E:J------LI:IJ-- - ---------- ow . flT I 0jI j 0 Ti ,89 i 11 " 4111, [ 41, ----------------------------------------- L L S ttStOLttSL NCC IL iSLC :a I LOS St OflWCflHJ) 'I 00 SMOKE DETECTOR I. NOT-NbG 1--2--L-X--P,, IJ-,L—L STATION MUNIAG OCACA (4) r 66111144046 040X-4.750 T_[000000001 wiTh LI ll T g I II II I i II I0 II II 0! _IL WT j J. 14511 1 ACOX AND BATTERY BOX. FIRV0IC-25/50 SRJS I-In- ,-i/r acm ELEVATOR SI-IAPT DETAIL ®_EXCDRAPPUANCS FIU wis J 9wE 00 m a am .. N0III 114116 III U 1414 W414ITh0000W(I14Wfl11 f' I I 111 5OAI.rw0ll MOUNT ME 0W-NON A T)-GANG 010CIRJC.ALNCAJ(N J0103 00 eQ.0M.0Nt. wiTh A MNIMAN 0.R?ThOf 2 & Lmi.II.1=I NOM: l0JOOOJT3 ON 100 YOP OR SO1OQI 5)60.1.00 05007 W10N I9STN1JNG COIOIJtTIN A Th= 00606 EaLTMOIL BOX 75R00 GANG Lii FOU-&O ANNUNCIATOR NC- 100 RELAY MODULE. sF1000 00000j fur 82LMI0 I - JIM ENTERPRWES 53303)10wnm SR. CA 9203 (792) 747-0 P (792) 747-75)5 Mi 00392 39-210 tEam Si. SITE C PALM 03067. CA 91017 (7)0)300-5)49 FSI (192)3603-2027 5900400 9073910 • 1.00 Yom 51003)3 070/I) 190 I S21M NOTIPIIW camom 14 IN' tSNEScO 56010101 z - 01: i—OW o w Cl) 3 in I]: d°5 10 03< w o w < C,) AS BUILT 08/24/1 1 19, 0 0 - P90000t 15-103 5151 ONLL Mu 10411)0 MI 601210020 07/10111 P.lLr SNOT 0303A 160601/1)04 Ut1MS I= mte SR 663300)00304 CAlIOJC OI4 FA6 OF 6 5PAKf.R/5TR0B MT. DIAGRAM (9) 5PAR/5iROD INSTAL. DETAIL (10) NFW2- 100 CABINET DIM (II) TYPICAL DEVICE ftVATION5 (12]