Loading...
HomeMy WebLinkAbout2502 GATEWAY RD; ; FPC2017-0247; Permit4btyof PERMIT REPORT Carlsbad Print Date: 05/27/2021 Permit No: FPC2017-0247 Job Address: 2502 GATEWAY RD, CARLSBAD, CA 92009-1742 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132612000 Track #: Applied: 08/23/2017 Valuation: $43,998.46 Lot #: Issued: 09/11/2017 Occupancy Group: Project #: Finaled Close Out: 05/13/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: VIASAT BLDG. 10 -SPRINKLER TI 7 - 100 HEADS (16) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ALEXIS CASSIDY 1341 DISTRIBUTION WAY, U STE 14 1341 DISTRIBUTION WAY, U STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 106 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 01TAN * FIRE PROTECTION Fire Protection Contractor - License #989280 VIASAT BLDG 10 T. 1. 2502GATE WAY RD CARLSBAD, CA 92009 TITAN PROJECT# 17664 MATERIAL SUBMITTAL ( FPC20I7-0247 2502 GATEWAY RD AUGUST 21, 2880 Scott Street, Suite 105- Vista, CA 92081 760-295-3881 -phone - 760-295-3437 —fox www.titonfpinc.com FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response AIML V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /41/19 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. ,htauiic 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2713 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart For K-Factor when pressure is measured in Bar, multiply SA. units by 10.0. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. 1 X. A—c—taulic / /7 victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: El Standard: 5.0 mm LII Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap; Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: LI Open End: V27 El] Recessed: V27-2. Sprinkler Finishes: LI Plain Brass LI Chrome plated LI White painted3 LI Black painted3 LI Custom painted3 LI Proprietary Nickel Teflon2 coating3 LII VC-2504 155, 200, 286 SR Only: LI Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 4 2014 Victaulic company. All rights reserved. victaulic.com 2 \4taulicr V victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model ________ APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" /2" 1/2° Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved _Temperature _Ratings 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/680C 155°F/680C 155°F/68°C 135°F/57°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/680C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/1410C 2860F/1410C 2860F/1410C 200°F/93°C 360°F/182°C 360°F/1820C 135°F/57°C 135°F/57°C 135°F/57°C 1350F/57°C 1550F/680C 155°F/68°C 135°F/570C 155°F/68°C 1550F/68°C 135°F/57°C FM 175°F/79°C 1750F/79°C 155°F/680C 175°F/790C 175°F/790C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 2860F/141°C 200°F/93°C 286°F/1410C 2860F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/570C 135°F/570C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/680C 1550F/680C 155°F/68°C 155°F/68°C 135°F/57°C NYC/MEA 62-99-E 1750F/79°C 175°F/790C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/1410C 286°F/141°C 286°F/1410C 286°F/1410C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/570C 135°F/57°C 155°F/68°C 155°F/680C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C CSFM 7690-0531:112 175°F/79°C 1750F/790C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/930C 200°F/930C 200°F/93°C 175°F/79°C 2860F/141°C 286°F/141°C 286°F/1410C 286°F/141°C 286°F/1410C 200°F/93°C 360°F/182°C 360°F/1820C 135°F/57°C 1550F/68°C 135°F/57°C LPCB 175°F/790C None None 1550F/680C None None 200°F/93°C 175°F/79°C 2867/141 *C 200°F/93°C 360°F/182°C 135°F/570C 135°F/57°C 1350F/570C 1350F/570C 155°F/68°C 1550F/680C 135°F/570C 155°F/68°C 155°F/68°C 135°F/57°C VNIIPO 175°F/79°C 175°F/79°C 155°F/68°C 1750F/790C 175°F/79°C 1550F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/1410C 200°F/93°C 360°F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/680C None 155°F/68°C 155°F/68°C None 200°F/93°C 200°F/930C 200°F/93°C 200°F/93°C 135°F/57°C 155°F/68°C VdS 175°F/79°C None None 175°F/79°C None None 200°F/930C 286°F/141°C 135°F/57°C 155°F/68°C 1550F/680C CE 175°F/79°C None None 175°F/79°C None None 200°F/93°C 286°F/141°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 \4taulicr victauic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: 17A6/ 37 mm 2W! 60 mm 1 WI I 41 mm 1W/ 2W/ 41 mm 60 mm I Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W/SO mm Max. Hole 2"/51 mm Min. Hole lW/ Typical Ceiling Tile ________________ 3 _________________ //L I ., , 17mm , lW/ Finished Surface 30 r 43 mm ________ MAXIMUM RECESS 75 mm MAXIMUM EXTENSION W Adjustment Recessed - V2707, V2708 (drawing not to scale) 2W/SO mm Max. Hole 2?51 mm Mix. Hole lVa"/ I _,, 37mTypical Ceiling Ill 2_L18mm_____ __ 24 mm iy •, MAXIMUM RECESS 24mm Finished Surface _________ 75 mm MAXIMUM EXTENSION 3/4'Adjustment Recessed — V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 4 \J'(ct -au Iic. Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent Distribution Patterns - Trajectory 3.010 8 2.401 6' L8n, 4. 1.2,0 2' 0.010 0 *IIIIIIIIITI \. •% 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 0 victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 I lu .1 1. 0.601 1.2,0 1.801 2.410 3,001 3.700 4.301 Models V2703, V2704 1<5.6 Standard upright Distribution Patterns - Trajectory uI.uuIuIu.I. MM MMMMI mmmmmmmm MM mmmmmmmm 2' 4' 6 8 10' 12' 14' 16 0.600 1.200 1.8,0 2.400 3.orn 3.70, 4.3,0 4.9o0 NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 5 \4taulic r 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLocktm I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - Glass Bulb color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 1350F/570C 1000F/380C Orange Ordinary C 155°F/680C 100°F/38°C Red Intermediate E 1750F/790C 150°F/65°C Yellow Intermediate F 2000F/930C 150°F/650C Green High J 286°F/141°C 2250F 81107°C Blue Extra High K 360°F/1820C 300017/1490C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707, V2708 Pendent / / V2707, V2708 Recessed Pendent / - V2703, V2704 upright - / WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. O Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. WE Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or Contact Victaulic for details. Note This product shalt be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 6 Atc-t _au - Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube0 made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's0 Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. c®ijs LISTED APPROVED ONFSA NFPA' 4 NOMINAL PIPEO.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 iL 5.62 lbs/ft 11796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE [i± 1 1/2[190O l 1610 T100 L 272 FDs/ft 362 fl 44 L2Jr2375 3661&stff_] E-2— [ 7 1L L2ä too-1— Ibf LThoo 7-4* J 4500 - 4026 io Ob 'Only available in Casa Grande. AZ "corrosion Resistance Ratio per latest Ut. Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Y For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ Dallas, TX Masurtt OH 63017 Dull Moose Tube's® Eddythread 40® ADVANTAGES OF BULL MOOSE TUBE® EDDVTHREAD 400 I) is lightweight replacement for Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion Has a pressure rating of 300 psi. Resistance Ratio of 1. Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM A135 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MIC preventative coating. EDDVTHREAD 40® SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB./FT WEIGHT SIZE corrosion Resistance Ratio per latest UL Directory listing c®us LISTED PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. APPROVED 14-1 ONM NFPA' For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ DallanTX Masurit OH 63017 Bull Moose Tubes® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2'. Eddylite® is truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM A135 and A795 specifications, This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED AFPR6V NFPA 6 ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1.315 0.13 JL. 1.260 1.700 91 E 11/4 ir 1660 Iir 1482 r9 16i7 —2-364 6i 1 1/2 1.966 1.712 012 453 1 967 2 965 61 r 2 11 ?Z ir 2177 016 1( 431[ 2617 ir 4230 1L - 'Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com rar9clatksonRoad Chesterfield, MO Gerald, MO Kent,wA Casa Grande, d2 Dallas, TX Masuw OH 63017 Bull Moose Tubes® Eddy Flow® is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flows® larger ID provides an opportunity for downsizing and further cost savings. c®us LISTED ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® Certified to ASTM Al 35 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight -saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD Il® MIC preventative coating. NPS O.D. EDDY FLOW® EDDY FLOW® WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR* PER FT. WI. SIZE L 1.222 2.019 61 LiIii iEiiI JLII III LI IL L !OII LI LIII [iJ 7°5I]L96 liii [IiIiII iLii 0 [ I iIIILIIL PLIJL lLi]EIfli.]LIILI! [_11.290 19 corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. APPROVER M A ONFSA NFPA For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com U l8l9 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grandt, AZ Dallas TX Masury, OH 63017 7 Dull Moose Tube's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® I.) a versatile product that can be Certified to ASTM Al 35 and A795 Type F, Grade A. - roll grooved, welded, and used with FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy®offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS 0.D, ULTRA ULTRA EDDY° WEIGHT WATER BUNDLE (IN) (IN) EDDY° (ID) CRR** PER FT. FILLED WT. SIZE 1.315 1.201 2.17 .868 1.359 91 HIM iii Pressfit is a Registered Trademark of Victaulic company of America Corrosion Resistance Ratio per latest ui Directory Listing c®us LISTED APPROVOl A. - — 0 A FM NFPX 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Keel, WA Casa Grande, AZ Dallas, TX Masury, OH 63017 NPS (IN) 1 1-114 1-1/2 2 2-1/2 3 4 c®us LISTED AFPRQVm ULTRA EDDY 0.D. (in) 1.315 1.660 JL 1.900 2.375 - i201 [5.iu1fl786 2261 0868 Th07 iLiiI ii [ ID(in) ptyWe6W Water.FiIIedWg Lt )Lt359 OD.(in) 1.900 fT37S 75T oo uit III3LJ t° iiii EDDY FL0W (jptyW&ghi(th/ft)_JJ flT222 T44 t2TH 3T1 (TU 2.860 flJ LII!iIIIJ E 7!I]LIII!!IIIJ ___ L 00 E-7-00LJ99i SCHEDULE IDnJL p gtoJLj4i0 1Lj81o1 Lillill) Water v0ed Weig LJIII] C R C LL LIi11 1083 1LiLLiLiiiLi2iIiiiiLiiiiiiiLIiiiii1 [ EDDYLITE L 00. nLj [iIII] [II] II]LIIIIII] 1 .0. (j LJ] ETh [1 Ii1LiII1 LJL Lillillil _ i[_____ [111111] Lpjg(!)1 L 1.260 [jf Water.9IIedWghtlIb/ft)]L IIIIILIIIIIJ EDDYTH EAD Li is ioo Li ii LLi1 ID (st)jL L o b1ft Ixt (L JriLiL °7°HLilLiL I 11111 LuliTh Li ill LWate,-Filled WegLt Ott) [_1 860__ r 468 2J5 iiii LI2.37=5 U riiiiiiiriiiiiii Lililill riii ii SCHEDULE [pn)_J LJJ L L049J [:=1.380 [ [iooj 1.610 rFiIledW&g 4 2.875 1 jjII EIiIi] J LII 00 iI 026 I ID. (inLijjiJ 36 JLIIiILIIiI1LJoiiiLIIiILi 1.00 JLJflij NFPA For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Cladcson Road / Chesterfield, MO Gerald, MO Kent WA Casa GrandL AZ 63017 www.bullmoosetube.com sales@bullmoosetube.com Dallas 1)( Masurt OH 9 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE c®us LISTED APPROVE) NFPA 10 ULTRA EDDY 0.868 91 1,659 1,896 1,975 SCHEDULE 10 1.410 91 2,695 3,079 3,208 1 EDDYLITE 1.260 91 2,408 2,752 2,867 DYTHREAD40® i41 70 2148 2454 2,557-1 1.680 70 2,470 2,822 2,940 I ULTRAEDDY 1.107 61 1,418 1,621 1,688 [_EDDY FLOWS t1.222 61 1,565 1,789 8 11/4 1 SCHEDULE 10 tl.8101 9 26S 2T7O] I_EDDYLITE t1.617 61 267 2466 I EODYTHREAD 40 2.070 51 I272i 7 Z534 2763T9 2_270 L11I1II1IIII1JL1III11 11i121 I111JL1II!!111J ULTRA EDDY ]E11.74nr613p1632j[186511L19431 11/2 FEDDY FLOWS IF1844'1 i1IL 111 82 1 I SCHEDULE 10 EDDYLITE 2090 61 2520 2880 30 !EDDYTHREAD40 2547 2J _____ SCHEDULE I ULTRA EDDY 1L11i1111J ~ 424 484 I EDDY FL0W ]E 2.330 1 LLJL 81O] [O69jL 155 J [SCHEDULE 10 I .640111) C [111 11111] LII 411111111111iI1I] 2 EDDYLITE I [_1I111j L 37 111O33 ________ EDDYTHREAD 40 ]L1Ij LiII FI1111I11LIIL11iI111i C SCHEDULE 40 jL3I1iL_3_IL112,30q1IIL111111111111145 [ 21/2 1 I EDDY FL0w1 30 111111i1I11 IL 111 2809 E1rTh27 1 [i2I11254211L26481 1~6 1 SCHEDULE1O 1L111I1I [ SCHEDULE4O 3 EDDY F10W ILti F 19 LI1' 1 SCHEDULE 10 It 4.340 F SCHEDULE 40 1t 7.:58 T11 3,O24 1L11]11 E1Iö1 1 4 L EDDYFL0W E:- 96C= 19 1L JEI1I11111 11j :r IL 2,360 4L ....L 111LIi3!II r SCHEDULE 10 1L1i11I 10 800 LnviL11 [ 6 - 8 16.440 Only Mailable in Casa Grande. AZ. BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpii') lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE7-05 ) & Ci,for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft. 251t. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 1/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1012 867 726 40 40 40 40 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to F-ILF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 c®us LISTED APPR 0881 ca AfA NPPA Q For Additional Information Contact (800) 325-4467 www.bullmoosetube.com .. Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ Dallas, TX Masury, OH eas,.*TunnMpANY 63017 11 STYLE 922 The Style 922 Outlet-I provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-I is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade 'E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade 'E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para___________ Location Date Approved www.victaulic.com VIcTAuLIc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTALILIC COMPANY. ALL RIGHTS RESERVED. REV_G 4tauIicf 10.52_I IPS CARBON STEEL PIPE. HOLE CUT PRODUCTS 10.52 _jii_ 41 _________ .]lN1r.J,flTTTI1I1ITTaw Appr x. Weight Each 14 ½ 32 15 1 30.2 1.30 33.0 1.83 46.5 1.10 27.9 3.87 98.3 2.56 65.0 1.0 0.45 3.87 98.3 20 1 30.2 1.28 32.5 1.83 46.5 1.10 27.9 2.56 65.0 1.1 0.50 1 25 1 536 30.2 1 516 30.2 1.52 38.6 1.42 36.1 2.18 55.4 1.95 49.5 1.10 27.9 1.22 31.0 3.87 98.3 4.08 103.6 2.56 65.0 2.56 65.0 1.2 0.54 1.2 0.54 1½ x ½ 40 15 3/4 20 1 3A 30.2 1.40 35.6 1.95 49.5 1.22 31.0 4.08 103.6 2.56 65.0 1.2 0.54 1 25 1536 30.2 1.64 41.7 2.30 58.4 2.19 55.6 1.22 31.0 1.46 37.1 4.08 103.6 4.60 116.8 2.56 65.0 1.3 0.59 1.3 0.59 2 x ½ 50 35 1516 30.2 1.66 42.2 2.56 65.0 3/~ 20 1,16 30.2 1.64 41.7 2.19 55.6 1.46 37.1 4.60 116.8 2.56 65.0 1.4 0.64 1 25 13A6 30.2 1.88 47.8 2.54 64.5 1.46 37.1 1.71 43.4 4.60 116.8 5.40 137.2 2.56 65.0 1.5 0.68 1.6 0.73 21/2 ½ 65 15 1 ,16 30.2 3.91 48.5 2.44 62.0 2.56 65.0 3/4 20 1 3M 30.2 3.89 48.0 2.44 62.0 1.71 43.4 5.40 137.2 2.56 65.0 1.6 0.73 1 25 PM 30.2 2.13 54.3 2.79 70.9 1.71 43.4 5.40 137.2 5.50 139.7 2.56 65.0 2.56 65.0 1.6 0.73 1.6 0.73 761 mm X ½ 15 PM 30.2 3.91 48.5 2.44 62.0 3.71 43.4 2.44 62.0 1.71 43.4 ~ 20 1536 30.2 1.89 48.0 5.50 139.7 2.56 65,0 1.6 0.73 1II6 30.2 2.13 54.1 2.79 70.9 1.71 43.4 5.50 139.7 1 25 2.56 65.0 1.7 0.80 FireLock® Outlet-I STYLE 922 DIMENSIONS Ifni I3. 01 I II I. A Ui t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02009 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. 1O.52_2 \4taulicr REVG IPS CARBON STEEL PIPE HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com Ataulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 10.52_3 STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 Ac--tauIi VITAULIC IS A REGISTERED TRADEMARK OF vICTAULIC COMPANY. © 2009 ICTAUC COMPANY. ALL RIGHTS RESERVED. X. 10.52 ':4 uctile Iro n. Threaded Fitting.4 -F . ~ SMITH -COOPER INTERNATIONAL Ductile Iron Threaded Fittings rspecifi!oi branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP u us Ductile iron castings conform to ASTM A536 c ®L LISTED Fitting dimensions conform to ASME 1316.3 Bushings and plugs conform to ASME B16..14 FM Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & phy$ical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshoctk psiG 30D# Class Threaded Fittings -20 to 100 500 150 500 200 480 : 250 -. 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 ce", <~> APPROVED LISTED Fig. 35E3-90° Elbow I I Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 35E3006 1.31 70 140 0.3 I 1 35E3010 1.50 40 80 0.5 1-1/4 35E3012 1.75 25 50 0.8 I_1-1/2 35E3014 1.94 18 36 1.1 12 35E3020 2.25 10 20 1.8 I 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number _ A in - B in Packing Weight lb Inner Master 3/4x1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1.58 1.67 30 _60 0.7 1-1/2x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-1/4 35RE3014012 1.82 - .88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 351RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 13 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2x2 35RE3024020 2.39 2.60 6 12 25 Fig. 35F 3-45° Elbow I Size in Part Number A in Packing Weight lb Inner Master I_1/2 35F 3004 0.88 150 300 0.2 I3/1 35F 3006 0.98 80 160 0.3 I 1 35F3010 1.13 40 80 0.5 1-1/4 35F3012 1.29 25 50 0.7 1-1/2 35F3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F3024 1.95 4 8 2.7 ID F! Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner I Master 1/2 3513004 1.13 80 160 0.3 3/4 3513006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 3513012 1.75 10 20 1.1 1-1/2 3513014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 • www.srnithcooper.com Size in Part Number ____ A in B in C in Packing_ Weight lb Inner Master 3/4x1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 lx 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1x3/4x3/4 35R13010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 351RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4xlx1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x1x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x1x1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0.. 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2_ 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x3/4x1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35R13014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-1/4 35R13014012 1.82 1.82 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35R13014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35R13014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35R13014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2x 1/2 35R13020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 .73 - .73 - 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x 1-1/4 35RT3020012 1.90 _1.90 2.10 8 16_ 1.9 2x1-1/4 x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 Th.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 1 2x1-1/2x1-1/2 35R13020014014 2.02 1.94 2.16 8 16 1.8 I c®US <E> APPROVED LISTED Fig. 35RT3 - Reducing Tee Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1 35BT3006010 1.45 1.45 1.37 30 60 0.6 x1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1 x1-1/2 35B13012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 BT3012020 2.10 2.10 1.90 10 1 20 1.6 1-1/2x1-1/4x2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 35B13014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 9 www.smithcooper.com 112 cous APPROVED Fig. 3503 - Straight Coupling with Ribs USTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 350P3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35H83010004 1.06 180 360 0.2 1 x3/4 35HB3010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2x1-1/4 35H83020012 1.38 40 80 0.6 2x1-1/2 35H83020014 1.38 40 80 0.6 Fig. 355P3 - Square Head Plug II Size in Part Number A in Packing Weight lb Inner Master I 1/2 35SP3004 0.94 600 1200 0.07 13/4 35SP3006 1.12 350 700 0.1 I 1 35SP3010 1.25 200 400 0.1 I 1-114 35SP3012 1.37 100 200 0.3 I 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner I Master 1 x 1/2 35RC3010004 1.69 80 160 0.3 lx 3/4 35R03010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2x1 (not hex) I 35RC3020010 2.81 20 40 1 1.0 Fig. 35HB3 -Hex Bushing Fig. 35U 3- Union with Brass Seat Size in Part Number _______________ A in Packing Weight lb Inner Master 1 35U3010 2.19 20 40 1.0 1-1/4 35U3012 2.50 15 30 1.2 1-1/2 35U3014 2.62 10 20 1.7 2 35U3020 1 3.12 1 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.srnithcooper.com I I Size i n Part Number A in Packing Weight lb Inner Master I 1/2 35C 3004 0.87 300 600 0.1 I/4 35C 3006 0.97 200 400 0.1 I 1 35C3010 1.16 110 220 0.2 I 1-1/4 35C 3012 1.28 70 140 0.4 I_1-1/2 35C3014 1.33 50 100 0.5 I 2 35C 3020 1.45 25 50 0.8 2-1/2 35C3024 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp C&US <~> APPROVED A A Fig. 35X 3- Cross LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 1 2.8 qai Fig. 35RX3 - Reducing Cross I Size ' I in I I P art Number I A I in I B I I in I Packing I Weight I I I I lb I I Inner . I Master 1-1/4x1 I 35RX3012010 I 1.67 I 1.58 I 15 I 30 1.2 I 11-1/2x1 I 35RX3014010 I 1.801 1.65 I 12 I 24 I 1.4 2 x 1 35RX3020010 I 2.02 I 1.73 I 8 I 16 2.0 Fig. 35C 3- Cap I I Size _in Part Number ______ A in Packing Weight lb Inner Master I_3/8 35BC3003 0.75 100 200 0.3 I_1/2 35BC3004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 114 INSTALLATION STEPS -jflIINTO WOOD & STEEL: 1 IINSTALLATION STEPS .II94OkUINTO WOOD & STEEL:J Insert the appropriate nut driver into a 3/8" or 1(2" portable drill. Insert the SAMMYSO into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position Push the face of the nut driver tight to the member Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 112" or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. H1L4H_1 I. Insert the appropriate nut driver into a 3/8" or 112" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8", Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. iIUifmI INSTALLATION STEPS -JINTO CONCRETE: Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 81139 10) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 112", or metric all thread rod or bolt stock. (#I4SW red nut driver used with 1(2" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS -I j4i'JfINTO CONCRETE: Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammerl rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drilO, and insert the #I4SW (red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. fr The SWC screw is ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin.otf feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. SAMMyg FOR STEEL F' n2dril ling Made with Teks° self-drilling fasteners - no pie-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range 010-2500. Made in the U.S.A. wthe deodemcsr.frcoT\ www.itwbulldex.comJ 1/4" 8024957 DSTR 100 • 1/4-20 x TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1 1/4 8025957 DST 100 1/4-14 x V TEKS 3446(20ga.) .036"-20 ga 3/16" 25 125] 1/4" 8026957 DST 150 1/4-14 x 1-1/2" TEKS 3 970 (16 ga.) .036"-20 ga 3/16" 25 125 1/4" 8027957 DST 200 1/4-14 x2TEKS3 446 (20 ga.) .036"-20ga 3/16" 25 125 1 1/4" 8030957 TEK 500 12-24 x 1-1/2" TEKS 5 3125 (3/16") .188-3/16" 1/2" 25 125 3/8" 8038957 DSTR 1 * 1/4-20 xl" TEKS 31510(20ga.) 1500 1475 .036"-20 ga 3/16" 25 125] . <f> 3/5" 8037957 DSTR 1-1/2 * 12-24 x 1-1/2" TEKS 5 1510 (3/16") 1500 1475 .060-16 ga. 1/2" 25 125 #14Black E" 3/8" 8039957 DSTR 5/1618x1.1/4"TEKS3 2200 (20ga.) 1500 1475 .036"-20ga 3/16" 25 125 Nut Driver 446 (20 ga.) Parl#8113910 3/8" 8040957 DST 10 1/4-14 xl" TEKS 3 970 (16 ga.) .036-20ga 3/16" 25 125 3/8" 8077925 DST 10-SS 114-l4xl" TEKS 3 446 209a) .036"-20ga 3/16" 25 12] 970 (16 ga') 3/8" 8041957 DST 15 1/4-14x1-1/2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (l6ga.) 3/8" 8078925 DST 15-SS 1/4-14x1-1/2" TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 1 970 (l6ga.) 3/8" 8042957 DST 20 1/4-14x2"TEKS3 446 (20 ga.) 970 (16 ga.) .036"-20 ga 3/16" 25 125 3/8" 8043957 DST 25 1/4-14s2-1/2 TEKS 3 446 (20 ga.) 970_(l6ga.) .036"-20 ga 3/16" 25 125 3/5" 8044957 DST 30 1/4-14x3TEKS3 446 (20 ga.) 970 (16ga.) .036"-20 ga 3/16" 25 125 3/8" 8045957 DST 516 5/16-18x1-1/4 TEKS 31500 (3/16") 1500 1475 .125-1/8"3/18" 25 125] " 3/8"8046957TEK5012-24x1-1/2" TEKS 53125(3/16")15001475.250"-114"1/2"25125 8031925 DST 2.0 1/4-14x2"TEKS3 446 (20 ga.) .188"-3/16 1/4" 25 1 125 I 970(16ga.) ________________j 1/2" 8033925 DSTR 1.0 1/4-20x1" TEKS3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/2"8034925DSTR5.16" 5/16-18x1-1/4"TEKS32220(20 ga.) .036-20 ga3/16"25125] 1/2" 8035925 DST 5.16 5/16-18x1-1/4" TEKS 3 1500 (3/16") .125-1/8 3/16" 25 125 #14 SW Red 1/2" 8036925 TEl< 5.0 12-24 x 1-1/2" TEKS 5 3125 (3/16") .188"-3/16" 1/2" 25 125 Nut Driver Part#8114910 includes retaining nut () -" Y SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. ZAHHIY6~ 0 LIZ W" Hi.)' dL•1i'DfUlI('I(k. Made with Tekse self-drilling fasteners - no pre-drilling required. 110 Installs into steel range from 20 gauge - 1/2" thicknesses. drl fl9 A standard screwgun with a depth sensitive nosepiece should be used to equ%re install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. re Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. -wttho video demcreJmUoe of \ Made in the U.S.A. ijwww.itwbuildex.comJ 8047957 SWO 100 1/4-14 xi" TEKS 3 1477 (16 ga.) .060-l6ga 3/16" 25 125 C - 1/4 8049957 SWDR WO 1/4 20 TEKS3 1900 (2-0g a.-)-- 20ga3/16 12j s 8050957 SWD 10 1/4-14 x 1 *TEKS3 1477 (16ga.) .060-l6 ga 3/16" 25 125 [ 80925SWDSS1x1TEKS 314776ga) 060 ga 3625 3/8" 8051957 SWD 15 1/4-14 xl-1/2TEKS3 1477 (16ga.) - .060"-16ga3/16"25 125 E3/88052957SWD201/414x2TEK5314776ga .060--16 ga 3/16 25 125 3/8" 8053957 SWD 516 5/16-18 x1-1/4" TEKS 3 2480 (20 ga.) .036"-20 ga 3/16" 25 125 LITTI xl TEKS3 1900 0 ga) 1500 5020043fl625 #14 SW Red 3/8" 8054957SWDR1-112 12-24 x 1-1/2" TEKS 5 2375 (3/16") 1500 1475 .188"-3/16" 1/2" 25 125 Nut Driver 3/8 8056957SWDR 516 5/16-18511/4TEKS 3 2480 (20 ga) 1500 1475 036__20'ga 3116- --::15 i2-57] Part #8114910 - 3/8" 8057957 SWT 15 12-24 x 1-1/2TEKS 5 2375(3/16") .188"-3/16" 1/2 25 125 includes retaining nut Part #8273910 "Does not comply with ROHS requirements/Includes retaining nut SAIPI1IVi V AX_PRESS Installs into Metal Deck, Purlin, or Tubular Steel The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or pudin (22ga. - 1/8"). Installs in seconds with Sammy X-Press It° Toot, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. 'Made in the U.S.A. Wathdeodnestmtkeot www.itwbulldex.com 1/4" 8181922 XP 200 Sammy X-60 1146(229a)1115 (Luminaire) 250 (Luminaire) .125' 25 125 Metal Deck 1 850(2%' Pipe) .027 Sammy 85 (Luminaire) 3/ 8150922 XP 20 1146(22ga) 1475 .104' .125' 25 125 Metal Deck X-Press 20 250 (Luminaire) 283 (Conduit & Cable) .029' 1500(4' Pipe) .060' .. 3/8' 8153922 XP 35 X 's? s 1783 (16ga) 250(Lurninair:) .056 1475 (4' Pipe) :? .125' 25 125 Pudin 416 (Conduit & Cable) .059' r I Metal De,,k~ I Pre-Pour Structural Concrete@ 3000 psi 3I8 8150922 XP 20 Sammy 1146(22ga) 850 (2Y, 25 125 (Pre-Pour) L I X-Press 2 Post-Pour Range 11 LWC!5 35 PCF (lbsJft) Metal Deck ______(t-pour) Pre-Pour structural Concrete @3000 psi Post-Pour Range 0 LWC 35 PCF (IbsI ft') The Sidewinder X-Press expands to provide horizontal attachment in: - 16 ga - 3/16" steel - pudin, tubular steel. Installs in seconds with Sammy X-Press It° Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. 'Provides design flexibility. 'Made in the U.S.A. a deo dms0ce\ www.itwbuildex.comJ Sidewinder 3/8' 8293957 SWXP 35 X-Press 35 Aek 1 010, 1798(l6ga) 80 ILuminairel .059' 125' 25 125 Purtin for reme or 3raflt T. ites 2ANN7915 The SwiveiX-Press allows you to hang plumb in extreme roof pitches: - 89 in z-pudin - 45 in metal deck for 12/12 pitch Installs in seconds with Sammy X-Press 90 Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. le. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. a video demonst,atice at G=Dwww.itwbuiidex.com 750(2' Pipe) Swivel L 3/8' 8294922 SXP2O 1061 (22gaVert) 170 Vertical (Luminaire) 80th 45' (Luminaire) .0 635 (2' Pipe) 029' 29 829(45' 06 V 283 Vertical (Conduit & Cable) - 233 @ 45' (Conduit & Cable) 1250(3-1/2' Pipe) 3/8' 8295922 SXP35 Swivel X-Press 35 1675 (16ga Vert) 250 Vertical (luminaire) 80th 90' (Lumnaire) .959' .029 1558(89' Off Vert) 635 (2 Pipe) 500 Vertical (Conduit & Cable) 333 @ 89' (Conduit & Cable) Swivel 1/2' 8272957 SXP2.0 1061 (22gaVert) .027' .125' X-Press 2.0 829(45' Off Vert) 129' 25 125 Metal Deck 125 25 125 Purtin 25 125 Metal Deck 1/2' 8271957 SXP3.5 Swivel 1675 (16 ga Vert) x-Press35 060' .125 25 125 Pudin .17 V The Sammy X-Press expands to provide direct vertical attachment in: -metal deck (22-16gauge) z-purlin (18-16 gauge) Made in the U.S.A. Part Number Model !I L 8194910 - UXT' Universal X-Presslt Tool l 8152910 XPDB 25/64' Drill Bit 1 'ool Includes: Sleeve, Bit Receiver, Hex Vdench, and 2544 Drill Bit. APPROVALS 8007957 GST 10 3/8" Vertical CPVC 1-1/2' 300 1-1/2' 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2' 8008957 GST2O 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 GST2O-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST3O 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-1/2" 8009925 GST2S-380 3/8' Vertical 4" 1500 1-1/2' 8022925 SWG 25-380 3/8' Horizontal - 3-1/2'- 4** 1500 1-1/2" - 8021957 SWG 20 3/8" Horizontal 2-1/2'-3** 1050 1-1/2' 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2' 8269957 SH-GST/CST 20 3/8' 45" Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2' 4' 1475 1-1/2' 8038957 DSTR 1 3/8' Vertical 1500 .035' 4' 1475 .105" 8037957 DSTR1-1/2 3/8" Vertical 4" 1500 .035' 4" 1475 .105" L 8039957 516 _DSTR 3/8' Vertical 50 __.037 ___4" - 8045957 DST 516 3/8' Vertical 4' 1500 .188" 4" 1475 .188' 46957 TEK 50 I1 _Veral _!c_ 4" 1500 4" 8055957 SWDR 1 3/8' Horizontal 4" 1500 .037" 4' 1475 .060" [8056957 SWDR 516 3/8' Horizon 4" - 1500 .037'4 1475 .069' 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037' 4' 1475 .060" 1 8268957 SH-TEKSO 3/9' Vertical 2-1/2' 850 70' Angle off Vertical- _4"--------------1500 - -- 8150922 XP 20 3/8" Vertical 2-1/2' 850 .027' 2 940 .029" 8153922 XP 35 3/8' Vertical 4" 1500 .060' 4 1475 8294922 SXP2O 3/8" -'rticalorupto45 2" 750 .027"2" 635 .029' 8295922 SXP 35 3/8" Verticalorupto89' 3-1/2" 1250 .060' 2" 635 .029' 8293957 SWXP 35 3/8' Horizontal 3-1/2' 1250 .060' rSAMMYS FOR CONCRETE . PIPE HANGER - - L 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural ©3000psi 8150922 XP 20 3/8' Vertical 2-1/2" 850 Post-Pour Range II LWC :5 35 PCF (lbs/ft3) 185 .027' 8153922 XP 35 3/8' Vertical 250 .035" 027 8181922 XP 200 1/4' Vertical : Vertical 170 8294922 SXP 20 3/9' V 50 8295922 ------------SXP3S 3/8' -.-- 8293957 SWXP 35 3/8' Horizontal 80 .060' 8153922 XP 35 3/8' Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8' Vertical 283 .027" --max-4-trade-size EMT, RMC, and MC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060' Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 6293957 SWXP35 3/8' Horizontal------ _500 -.660'- ------Max 4 trade size EMT & 6 trade Sze RMC, MC and rigid PVC conduit 8149957 CZ2000 1/4' or 3/8' Onto Vertical Rod UL Listed 4S16- Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies wl NEC Standards ISheet Steel IGauges Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 118" 3/16" 1/4" Nominal Decimal Equivalent .030" .036' .048' .060" .075' .105' .125' .188' .250" 'SWG 25-380 Maximum pipe size Si composite wood joist allowed by ML is 3-1/2' ML compliance with NEC Standards. SING 25-380 Maximum pipe size Sr wood Smber or joist allowed by UL is 4' UL and FM tests were per/mined in compliance with NFPA 13 Standards. **SWG 20 Maximum pips size in composite wood joist allowed by UL is 2-I IT Fastening requirement 5 Sines weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118'. Subsequent testing was done for z-purlin applications in May 1997 using (.037') or 20 gauge steel. Most recently in 2008, testing with the new Sammy XPresse was completed using (.030") or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST2O .182' 1 118" GS125-380 .280' 7/32" SWG 20 .182" 1/8" SWG 25-380 .280' 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com wTEG AuOwThDASC*agyowchatHjn,,t&n AssoL,tD4MoaFofiLwaun Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, dxl, and .igs. Made in the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 \LILJU U -Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Listinas/ADorovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor IndeDendent code evaluation IBC®/ IRC®2015 lBC®/ lRC®2012 IBC®/ IRC® 2009 IBC®/ IRC® 2006 3.3.7 '1 -:--•-- Hilti, Inc. Inc. (U5) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 Mechanical Anchoring Systems 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications'-2 Figure 1 - KWIK HUS-EZ I anchor installation details wrench size Installation torque I -da 0. hei (Nm) (24) h0 Wrench size in. 7/16 1 is the maximum installation torque that may be applied with a torque wrench. - 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters dbit___ Table 2 - Hilti KWIK HUS-EZ I design strength with concrete I pullout failure in uncracked concrete' 2'3'4'5 Nominal Nominal Tension - cpN Shear - anchor embed. f' = 2,500 psi f' = 3,000 psi f' = 4,000 psi f' = 6,000 psi f'c = 2,500 psi f'c = 3,000 psi f' = 4,000 psi f'c = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) / 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' .2,3.4,5 Nominal Nominal Tension - qN Shear - q3v anchor embed. f'c = 2,500 psi f' = 3,000 psi f' = 4,000 psi f' = 6,000 psi f',, = 2,500 psi f' = 3,000 psi f' = 4,000 psi f' = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) / 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A as follows: for sand-lightweight, A = 0.68; for all-lightweight, A = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors"2 Nominal anchor Nominal internal Tensile3 Shear' Seismic shear' diameter thread diameter 4N,, in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1/4 / UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with 4V < 0.64A f,,, as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with a ip 0.60 f as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.tiilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter d 1 in. 1/4 Nominal embedment hr,om in. 1-5/8 2-1/2 Effective embedment h in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 - ft-lb 18 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concret&'2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 -L toward edge from edge factor in shear4 uncracked concrete IAN I RN JAy fm I RV IHV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a CU 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a )tj 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 9.E 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 g5 (127) 0.93 0.80 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 C (229) _9 1.00 0.86 CO 10(254) 0.89 1 11(279) 0.93 12(305) 0.97 14(356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete 1,2 Edgedistanceinshear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' ± toward edge from edge factor in shear4 cracked concrete f 'RN lAy fRy IHV Embedment in. 1-5/8 2-1/2. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2(38) 0.71 0.63 0.88 0.65 1 0.59 0.56 1 0.40 0.21 0.80 0.43 n/a n/a 2(51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a 2-1/2(64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3(76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4(83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4(102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 1 0.97 1.00 0.81 4-1/2 (1 14) 0.89 0.77 0.68 1.00 0.85 5(127) 0.93 0.80 0.70 0.89 LO 5-1/2 (140) 0.98 0.83 0.72 0.93 (152) 1.00 0.86 0.74 0.98 7 (178) 0.92 0.78 1.00 (203) 0.98 0.82 (229) 1.00 1 0.86 1 10(254) 0.90 11(279) 0.94 12(305) 14(356) 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, fA. assumes an influence of a nearby edge. If no edge exists, then 'AN = 4 Concrete thickness reduction factor in shear, fRy assumes an influence of a nearby edge. If no edge exists, then f = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. 3.3.7 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hitti.com I en espafiol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6,7 Installation in lower flute Installation in upper flute Nominal Nominal 1tern Nominal Tension - 4N Shear - cpV,, Tension - pN Shear - anchor thread embed. f'= 3,000 psi '= 4,000 psi f,,= 3,000 psi f= 4,000 psi '= 3,000 psi l= 4,000 psi f'= 3,000 Ps '= 4,000 Psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 1 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) / 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck"23'45'6'7'8 Installation in lower flute Installation in upper flute Nominal Nominal klt Nominal Tension - Shear - 4V Tension - qN Shear - On anchor thread embed. f',= 3,000 psi = 4,000 psi f'= 3,000 psi f'= 4,000 psi = 3,000 psi f= 4,000 psi f',,= 3,000 Ps = 4,000 Psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 ______ (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1/4 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by ON.,e5 = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (us) 1-800-879-8000 1 www.us.hitti.com I an español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2 - Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Mm. 3/4" CO Minimum 20 gauge steel deck pical) 1-1/4" - Min. 12" (typical) 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I II carbon steel screw anchor' .2 Nominal Internal anchor thread Tensile' Shear4 Shears diameter diameter N. V. V,eq in. (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile Ne,, = A N 4 f R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with V,, <A,, 4 0.6 f,, A as noted in CSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with v, 4), 0.6 f, R as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. ME 3.3.7 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hitti.com I an espanol 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 Mechanical Anchoring Syste rns 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 II Design parameter Symbol Units Nominal anchor diameter Ref 1/4 3.314 Anchor O.D. d in. 1/4a (mm) (6.4) Effective embedment2 hat in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment2 h,. in. 1-5/8 2-1/2 (mm) (41) (64) Minimum concrete thickness h min in. 3-1/4 4-1/8 (mm) (83) (105) Critical edge distance in. 2.00 2.78 (mm) (51) (71) Minimum spacing at critical edge distance in. 1.5 (mm) (38) Minimum edge distance c,,, in in. 1.50 (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 I 2-7/8 (mm) (51) (73) Minimum specified ultimate strength f.(N/mm') psi 125,000 (862) in2 0.045 Effective tensile stress area A (mm2) (29.0) Steel embed. material resistance factor for reinforcement - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes' R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 0.5.3 lb 3,370 Factored steel resistance in tension N, 0.6.1.2 (kN) (15.0) lb 750 Factored steel resistance in shear V, D.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic V,eq (kN) (1.5) lb 725 Factored steel resistance in shear V r 0.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic V,0q (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete k - 10 0.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete k - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 4j N - 1.0 D.6.2.6 Anchor category - - 1 0.5.3 (c) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (c) Condition B5 lb 665 ,645 Factored pullout resistance in 20 MPa uncracked concrete6 Nprur,c 1 (kN) 0.6.3.2 (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concrete N lb 340 815 D.6.3.2 (kN). (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete N,, lb 275 815 0.6.3.2 r,eq (kN) (1.2) (3.6) 1 Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. 2 See figure 1 of this section. 3 The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section D.2. 4 For all design cases, 4cN = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k,) or uncracked concrete must be used. 5 For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. 6 For all design cases, ip0 = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1 .4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 - Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure 141 in uncracked concrete'2'345 Nominal Tension - N Shear - V, __________ f', = 20 MPa I' = 25 MPa I', = 30 MPa f'c = 40 MPa f = 20 MPa f'c = 25 MPa f' = 30 MPa f'c = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1/4 / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure II in cracked concrete1'2'3'4'5 Nominal Tension - N Shear - __________ = 20 MPa f 'c = 25 MPa = 30 MPa f' = 40 MPa f 'c = 20 MPa f',. = 25 MPa I',, = 30 MPa f 'c = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by AQ as follows: for sand-lightweight, AC = 0.68; for all-lightweight, AC = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hitti.com I en espanol 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 Mechanical Anchoring Systems 1 HII] 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' .2,3.4.5,6,7 H Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - Nr Shear - Vr Tension - Nr Shear - Vr f = 20 MPa f' = 30 MPa f' = 20 MPa f = 30 MPa f' = 20 MPa f'c = 30 MPa f' = 20 MPa f = 30 MPa anchor thread embed. diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 .660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 .1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 ______ (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck 1.2,3,4,5,6,7,8 1±1 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - N Shear - V, Tension - N, Shear - V anchor thread embed. f'c = 20 MPa f'c = 30 MPa f'c = 20 MPa f'c = 30 MPa f', = 20 MPa f'c = 30 MPa = 20 MPa f = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) -(1.8) 560 560 1/4 / UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3:8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) See Section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h,,,,, (nominal embedment). Tabular value is for lightweight concrete and no additional reduction factor is needed. No additional reduction factors for spacing or edge distance need to be applied. Comparison of the tabular values to the steel strength is not necessary. Tabular values control. Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by = 0.75. For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1 -5/8 anchor - 0.45 For the 1/4x2-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 huh, Inc. (US) 1-800-879-8000 1 www.us.hitti.com I en español 1-800-879-5000 1 Nilhi (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels1'2 Hanger rod size Min. effective embedment h ef in. Allowable load' Ultimate load Tension lb Shear lb 4,1 Tension lb Shear lb 4,5 1/4-20 UNC 1-3/8 455 . 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in hollow core concrete 3.3.7 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum I Description diameter length diameter embedment Qty/,J KH-EZ 1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 [KH-EZ 1/4x2-1/2l1/4 1/4 3/8 1/4 2-1/2 100 J KH-EZ 1/4x1-5/813/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1I!!&.I/ 13/8 3/8 7/16 1/4 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hitti.com I en español 1-800-879-5000 1 Huh (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 13/is 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 1/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C 0 E F Load Lbs.* Wt./100 3/8 13A6 11/4 1 7/16 1 610 28 1/2 1½ 11/4 1 9/16 11/4 1130 55 5/8 1½ 1/4 1 9/16 1'/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/411 and 11/4" Throat Openings Component of State of California OSHPD Approved c VL US LISTED Seismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8, 1/2 and 5/8 rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset.design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 S CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25 - Surge Restrainer c®us LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 / COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Component of State of California OSHPD Approved c@ us usmo ; Seismic Restraints System Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range - Secures 3/8' thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 D OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. - CORONA, CA 92879 PH: 951.737.5599. FAX: 951.737.0330 CUSTOMER SERVICE • 8.786.5266 www.tolco.com Fin. 200 - I'M mline" Adiusthh!e Band Hanner lCnnner R-Line Fin R17flNFi ®TDLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B317ONFC) C,US USTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut FM Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. 44 Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily .. installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in / hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig. 2001/2. 200-/4 Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Fig. 200_21/2 to 200-8 Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200 Fig. 200C Fig. 200F Pipe Size RodlTI1p: Part No. in. (nim) in. (MM) ill. (nirn) lbs. (kg) 200-1/2 /2' (15) I8-16 31/8" (79.4) 2/8' (66.7) 11 (5.0) 200-/4 3/4 (20) /8"-16 31/8' (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) /8-16 33/8 (85.7) 2/8 (66.7) 12 (5.5) 200-1I4 11 /4 (32) /8 -16 33/4' (94.0) 2/8" (73.0) 13 (5.9) 200-1I2 11/2" (40) /8-16 3/8' (98.4) 2/8' (73.0) 14 (6.4) 200-2 (50) /811-16 41/2' (114.3) (76.3) 15 (6.9) 200_21/2 21/2 (65) /8 -16 5/8" (142.9) 41/8 (104.7) 27 (12.3) 2003 3" (75) I8"16 5/8" (149.1) 4" (101.6) 29 (13.3) Fig. 200S 200_31/2 31/2" (90) /811-16 7/8" (187.3) 51/4 (133.3) 34 (15.6) 200-4 4' (100) /8-16 7 /8 (187.3) 5° (127.0) 35 (16.0) 200-5 5" (125) 1/2"13 91/8 (231.8) 61/4 (158.7) 66 (30.2) 200-6 6" (150) 1/2"..13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"13 131/8 (333.4) 1 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PW COOPER B-Line Fig. 200_21/2 to 200-8 ®TOLCO c®Us USTED Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: - - - - (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily 7 installed around pipe. I (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig.200-1 to 200-2 Factory Mutual Engineering Approved /4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size . - - Designed to meet or exceed requirements of FM DS 2-0. ------ Part No. 2001V18-1/2 Pipe 1/2" Size (15) I I M8 31/8" Rod Size Approx. (79.4) 2/8' (66.7) ii Wt. II (5.0) 200M10-1/2 1/2" (15) M10 31/8" (79.4) 2/8" (66.7) 11 (5.0) 2008-3/4 3/4" (20) M8 31/8' (79.4) 21/2" (63.5) ii (5.0) 200M10-3/4 3/4" (20) M10 31/8" (79.4) 21/2" (63.5) ii (5.0) 200M8-1 1° (25) M8 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200M1-1 1" (25) MiO 3/8" (85.7) 2/" (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) M10 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M8-11/2 11/2" (40) M8 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) M10 3/8" (98.4) 2/" (73.0) 14 (6.4) 200M8-2 2" (50) M8 41/2" (114.3) 3" (76.3) 15 (6.9) 200M10-2 2" (50) M10 41/2" (114.3) 3" (76.3) 15 (6.9) 200M-2112 21/2" (65) M10 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3" (75) M10 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2 (90) M10 7/8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 4" (100) M10 7/8" (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 6" (150) M12 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200M-8 8' (200) M12 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8"-16 or 1/2"..13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 F & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. ®TOLCO .T1T5 Part No. 200H-2-3/8 • ii 2 ,. (50) Rod Size /8"-16 I 4/16' A (115.9) 3/32" B (81.7) 48 I (21.8) 200H-2-1/2 2' (50) 1/2"13 423/32" (119.8) 3/8" (85.7) 45 (20.4) 200H-2112-318 21/2" (65) /8-16 5/16" (134.9) 323/32" (94.4) 59 (26.7) 200H-21/2-1/2 21/2" (65) 1/2"_13 515/32" (138.9) 3/8' (98.3) 56 (25.4) 200H-3-3/8 3" (75) /8-16 53/4" (146.0) 3/32" (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"..13 5/8' (148.1) 331/32" (100.8) 60 (27.2) 200H-4-3/8 4" (100) /8-16 6/8" (174.6) 47/16" (112.7) 76 (34.5) 200H-4-1/2 4 (100) 1 1/2"13 71/32" 1 (178.6) 1 419/32' (1116.7) 1 73 1 (33.1) ° Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F. LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -10° to 150° Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ' System Compatible Program* Certified to NSF/ANS/Std 61 -G FB(%;r`.r SYSTEM COMPATIBlE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1800 344-3775 Nu © 2012 Fire Protection Products, Inc. FPPI5, LubeRtA are registered trademarks of Fire Protection Products, Inc. Ell FGG/BM/CZ', Blaze-Master, RowGuard Gold5 and Coaan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. miriiu FP P I® Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. E!P Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FBCV,-. SYSTEM COMPATIBLE *FBCT1 System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1800 344-1822 FAX +1800344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess salant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com © 2012 Fire Protection Products, Inc. FPPI, LubeFit® are registered trademarks of Fire Protection Products, Inc. kA FBC", BlaieMas(e,, RowGuard Gold5 and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. F P P I Description ThreadFit® CLEAR Thread Cuffing Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cuffing oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. 91, Nu © 2013 Fire Protection Products, Inc. FPPF', ThreadFiP are registered trademarks of Fire Protection Products, Inc. MADE IN U.S.A. Features Heavy Duty Cuffing Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FB(V;A SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300.