HomeMy WebLinkAbout2502 GATEWAY RD; ; FPC2018-0162; PermitCity PERMIT REPORT Carlsbad Print Date: 05/27/2021 Permit No: FPC2018-0162 Job Address: 2502 GATEWAY RD, CARLSBAD, CA 92009-1742 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2132612000 Track #: Applied: 05/23/2018 Valuation: $41,161.35 Lot #: Issued: 06/06/2018 Occupancy Group: Project #: Finaled Close Out: 05/13/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: PLAN REVISION: VIASAT BLDG 10 UV LAB - ALARM TI Applicant: FPContractor: iii ENTERPRISES THE STEIN HILBER CORPORATION SALOMON GOMEZ. 533 S VINEWOOD ST 115 MARKET PL ESCONDIDO, CA 92029-1924 ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 (760) 747-3050 x216 FEE AMOUNT FIRE Reinspection (per inspection) $187.00 FIRE TI Fire Alarm System $601.00 Total Fees: $788.00 Total Payments To Date: $788.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov I fpc2jD I S'-O (, •2 FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS ViaSat BLDG IOUVLAB Tenant Improvement 2502 Gateway Road Carlsbad, CA 92009 FIRE ALARM SYSTEM SENSOR Intelligent Non-Relay Photoelectric Duct Smoke Detector The lnnovairFlex'° Series are the only duct smoke fir ovair The InnovairFIex Series DNR and DNRW are intelligent (addressable) non-relay photoelectric duct smoke detectors. Like all InnovairFIex detectors, the DNR and DNRW both feature an adjustable housing design that fits square and rectangular installation footprints, mounts to both round and rectangular ductwork, and utilizes tool-free, plug-in sampling tubes for increased application flexibility and installation ease. These units sense smoke in challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of —4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing). For even more extreme environments like rooftops, the DNRW's NEMA 4-rated watertight and UV-resistant housing protects against windblown dirt and dust, rain, and hose directed water, enabling it to be installed without a costly enclosure, saving time and money. The lnnovairFlex housing cover isolates the sensor head from the low-flow feature for simple maintenance, and a cover tamper feature initiates a trouble signal for a removed or improperly installed sensor cover. The housing also provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module to meet specific application requirements. These detectors can be customized to meet local codes and specifications without additional wiring. The InnovairFIex line is compatible with all previous Innovair models, including remote test accessories, for easy retrofits. detectors flexible enough to fit configurations from square to rectangular and everything in between. Features Photoelectric, integrated low-flow technology (detector head sold separately) Air velocity rating from 100 ft/min to 4,000 ft/mm Adjusts to square and rectangular mounting configurations Broad ranges for operating temperature (-4°F to 158°F) and humidity (0% to 95% non-condensing) Patented tool-free, plug-in sampling tubes New cover tamper signal Increased wiring space with a new 3/4-inch conduit knockout Housing has space for mounting a relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection UL 268A listed Remote testing capability Requires com line power only NEMA Type 4 UL listed for non-hazardous indoor and outdoor applications (DNRW only) UV-resistant, UL-listed housing and cover material (DNRW only) WARNING: Duct smoke detectors have specific limitations. Agency Listings & <3> 0 MSFM LISTED APPROVED approved 2911 3029700 3242-1653:209/210 2125 InnovairFIex Duct Smoke Detector Specifications 141 . •.1 I The air duct smoke detector shall be a System Sensor InnovairFIex" DNR Intelligent Non-Relay Photoelectric Duct Smoke Detector and DNRW Watertight NEMA 4 Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke .detector fits both square and rectangular footprints.The detector shall operate at air velocities of 100 ft/min to 4,000 ft/mm (0.5 m/sec to 20.32 m/sec).The unit shall be capable of providing a trouble signal in the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch or remote testing using the RTS1 51 KEY remote test station. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Size: (Rectangular) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width; 2.5 in (6.6 cm) Depth (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth Weight: 1.6 lb (0.73 kg) Environmental Rating: NEMA 4 (DNRW only) Operating Temperature Range: —4°F to 158°F (-20°C to 70°C) Storage Temperature Range: —22°F to 158°F (-30°C to 70° C) Operating Humidity Range: 0% to 95% relative humidity (non-condensing) Air Duct Velocity: 100 to 4,000 ft/min (0.5 to 20.32 m/s) DCOIL (if included): 17.5— 26.4 VDC, 95 mA max Please see detector head installation manual for electrical specifications Device Standby Alarm RA100Z OmA 12mAMax. RTS1S1/RTS151KEY OmA 12mAMax. Installing the InnovairFIex Sampling Tube The InnovairFIex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right). A05 -04 22-005 Wirino for lntelliaent Non-Relay Duct Smoke Detector System wiring diagram for DNR: diagram for • COMM. '4 I LINE COMM. LINE I COMM. LINE(-) I I 1ST 2ND UL/FM LISTED CONTROL DETECTOR DETECTOR PANEL IN LOOP IN LOOP DNR to RA100Z: I I, RA100Z (-) I REMOTE ALARM LED OPTION 1 PER UNIT J DNR to RTS1 51 /RTS1 51 KEY with "R" Remote Test Capable Detector Head Option: TEST COIL+ TEST COIL— RTS151/RTS151KEY COMM+ OUT (CONV ONLY) + COMM— 2 L -[ JUMPER RAIRTS— Q RA +Q RTS+ DNR to RTS1 51/RTS151 KEY with DCOIL Option*: TEST COIL+ Q) TEST COIL -POWER EXTERNAL SUPPLY COMM+ OUT (CONV ONLY) + comm — J RTS151/RTS151KEY REMOTE TEST STATION RNRTS - LED OPTION RA+ 1 PER UNIT RTS + TEST COIL OPTION 1 PER UNIT 95 mA CURRENT DRAW *Important Notes The use of either the RTS1 51 or RTS1 51 KEY requires the installation of an accessory coil, DCOIL, sold separately. Please refer to the DNR or DNRW installation manual for more information. The RTS1 51/RTS151 KEY test coil circuit requires an external 24 VDC power supply which must be UL listed. A05-0422.00S Accessories System Sensor provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. TT II I' RTS151 UL S2522 RTS151KEYULS2522 RA100ZULS2522 Accessories DCOIL Remote test coil required with RTS45 1 /RTS451 KEY/RTS151/RTS1S1KEY DST1 Metal sampling tube duct width up to 1 ft (0.3m) DST1 .5 Metal sampling tube duct widths 1 ft to 2 ft (0.3 to 0.6 m) DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) DSTS Metal sampling tube duct widths 4 ft to 8 ft (1.2 to 2.4 m) DST1 0 Metal sampling tube duct widths 8 ft to 12 ft (2.4 to 3.7 m) P48-21-00 End cap for metal sampling tubes ETX Metal exhaust tube duct width 1 ft (0.3 m) M02-04-00 Test magnet RA100Z Remote annunciator alarm LED RTS151 Remote test station RTS1 51 KEY Remote test station with key lock DH4000E-1 Weatherproof enclosure 5!á"S7EII1 3825 Ohio Avenue St. Charles, IL 6017 i C20105ys1emSensw 4 Plod Cl spec ficasOrls subject to dsange without notice.hlsit systerosensorcorn lot $ SENSOR Phone: 800-SENSOR2. Fax: 630-377-6495 A05.0422.005- (0551st PlodUct ssfostea5ot including the latest version oltlisdata slteel 9/10. 52470 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ru OFFICE OF THE STATE FIRE MARSHAL It 0~' FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 3242-1653:0209 Page 1 of I CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (WI OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. Rev. 03-23-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6724:B3 FCM-1(A) & FRM-1(A) NOTE F! ER® Series 0 Control and Relay Modules by Honeywell General FCM-1(A) Control Module: The FCM-1(A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1 (A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1(A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1(A) may be used to switch 24-volt NAC power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Class B or A (Style Y or Z). Applications The FCM-1 (A) is used to switch 24 VDC audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScanO releasing applications. Construction The face plate is made of oft-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01-159). J97. ' EPWRI.) un 110 Et PW (,) FCM-1 (A) The FCM-1 (A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1(A) or FRM-1(A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1 (A) supervises Class B (Style Y) or Class A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1 (A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM.1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAC shorted.) DN-6724:B3 • 2/17/2011 - Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and Til): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 501N. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4' (101.6 mm) wide x 1.25 (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125" (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM-1 (A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5" (114.3 mm) high x 4" (101.6 mm) wide x 1.25" (31.75 mm) deep. Mounts to a 4" (101.6 mm) square x 2.125° (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved CSFM: 7300-0028:0219 MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM.1 (A) Current Maximum Load Application Rating Voltage Description 3A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded A .5 Inductive 30 VDC Coded (LIR=5ms) 1A Inductive 30 VDC Coded (LIR=2m5) .3A Inductive 125 VAC Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF0.35) Non-Coded Inductive .7 A 70.7 VAC (PF0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70 7 V RMS, 50 W A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mc-unt Backbox. CB500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1(A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document 156-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. Product Line Information NOTE: "A" suffix indicates ULC Listed model. FCM-1 (A): Intelligent Addressable Control Module. I I Notifier@ and FlashScan® are egistered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I O 9001 We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. mIIN&MNIUC1IR1N All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 464-7118. www.notifier.com Page 2 of 2- DN-6724:133 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0219 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev©honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION:. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt i This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division