Loading...
HomeMy WebLinkAbout2505 GATEWAY RD; ; FPC2017-0325; PermitPERMIT REPORT City of Carlsbad Print Date: 05/27/2021 Job Address: 2505 GATEWAY RD, CARLSBAD, CA 92009-1742 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2132601100 Track #: Valuation: $4,621,999.48 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check #: Permit No: FPC2017-0325 Status: Closed - Finaled Applied: 11/06/2017 Issued: 12/01/2017 Finaled Close Out: 05/13/2021 Inspector: Final Inspection: Project Title: Description: VIASAT CAFE AND CONFERENCE CENTER -ALARM TI (SEPARATE FROM SHELL ALARM PERMIT) Applicant: FPContractor: iii ENTERPRISES THE STEINHILBER CORPORATION SALOMON GOMEZ 533 S VINEWOOD ST 115 MARKET PL ESCONDIDO, CA 92029-1924 ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 (760) 747-3050 x216 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov mpmrmp EHmappmEs FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS FPC20I7-0325 2505 GATEWAY RD VIASAT CAFE AND CONFERENCE CENTER - ALARM TI (SEPARATE FROM SHELL ALARM PERMIT) 2132601100 11/6/2017 FPC20I7-0325 VIASAT CAFE AND CONFERENCE CENTER TENANT IMPROVEMENT 2505 GATEWAY ROAD CARLSBAD, CA 92009 jJBEALARMSSfEM BILL OF MATERIALS SYSTEM SENSOR PC2WL 2-WIRE HORN/STROBE, SELECTABLE CANDELA - CEILING MOUNT CSFM# 7125-1653:0503 SYSTEM SENSOR SCWL SELECTABLE CANDELA CEILING MOUNT STROBE ONLY CSFM# 7135-1653:0504 f~ SYSTEM SENSOR Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Aaencv Listincis SIGNALING APPROVED LISTED S5512 S401 FM approved except to, ALERT models 3057383 L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit Output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated tens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8 diameter x 2.5 high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9 diameter x 3.4 high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P. S, PC, and SC products will operate at 12 V nominal only for 15 and 30 Cd. AV0S86800 UL Current Draw Data tIJ.11 Candela Current 1gIiTKIiiY1;eYII1 fZ5Vlts DC T63 Volts f C FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 DC Input 8-1ZeVoIts 15cd 30cd —T1633V2!J 'fd 30cd 75cd 95cd 11 5c 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lK Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.lK Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 11 5c 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data horn and horn Strobe IMPUt (OOA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC - DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low -77 83 83 AVDSBG800 L-Series Dimensions 2.47 1.37 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe,B SCRL ,Strpbe, Red JW-Wre,1SeWàe ffSCWlJkAftI-r_;&ALE0Sir6q~jWb SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White STEM 3825 Ohio Avenue • St. Charles, IL 60174 ©20l7 System 00r Product specifications cat ons subject to chenge without no/ce. Visit systenwensor.com to, current product intormation, hctud/g the latest version of this data sheet. 5EItJSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 r r AVDSB68O1 .03/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of 2 CATEGORY: 5UDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: HWL, HRL, HOWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP and P2WL-SP Wall Horn Strobes; PC2RL and PC2WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-62, LENS-02, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering the test results and/or other data but does not make an independent verification of any claims. staff has reviewed This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires rièTZO, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2of2 SBBCRL and SBBCWL MP120 KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01; 2017.. Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 1 LISTING SERVICE LISTING No. 725 6530504....\ Page 1 of 2 CATEGORY: t2SF1REAM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listees data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date issued: July 01, 2017 Listing Expires Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division F" SYSTEM $ SENSOR® Outdoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrA lertO Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features Weatherproof per NEMA 4X, 1P56 Listed to UL 1638 (strobe) and UL 464 (horn) Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Rotary switch for horn tone and three volume selections Horn rated at 88+ dBA at 16 volts Rated from —40°F to 151°F Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed Plug-in design with minimal intrusion into the back box Tamper-resistant construction Listed for ceiling or wall mounting Agency Listings SIGNALING MEA_ ff530utdo0r strobes) LISTED ___________ S401 (chimes, horn strobes, norns) APPROVED approved L.z545.8Mhorn strobes, chime strobes) S3593 (outdoor and alert strobes) 3023572 MEA452-05.E 7135.1653189 (horns, chimes) SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet vir:ually any application requirement, including indoor, outdoor, wet and dry applications in temperatures from —40°F to 151°F Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with 3,4-inch top and bottom ccnduit entries and 3,4-inch knock-outs at the back. A screw-in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical TISpecifications Operating Temperature -40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/RNR1 Operating Voltage Range 8 to 17.5 V(12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7W x 2.5"D (1142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"Lx 4.7Wx 1.3D (142 mm x 119 mm x 33mmD) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7'L x 5.1"W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, S. PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVOSO 1201 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) EEIE= 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 185 NA NA 286 258 8-175 Volts rf6-33 Volts! Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA DC Input RMS), 2-Wire Horn 16-33 Volts 135 150 Strobe, 177 High Candela 185 Range (135-185 cd) FWR Input 16-33 Volts 135 150 177 Temporal High 245 259 290 297 Temporal High 215 231 258 2&' Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Horn Tones and Sound Output Data Horn and IHorn rStrobe !Output jy3 8-17.5 16-33 Switch Sound Volts Volts Position Pattern dB DC FWR DC FWR DC FWR DC FWR 24-Volt Nominal Reverberant Anechoic 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- High 82 82 88 88 93 92 100 100 rpora 5 Non- Medium 78 78 85 85 90 90 98 98 Temporal 6 Non- Low 75 75 81 81 88 84 96 92 Temporal 7f Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 -- 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDSO12O1 I Strobe Output J) I Listed Candela Candela rating at —40°F 15 15/75 Do not use below 32°F 30 75 44 95 70 _110 110 115 115 135 135 150 150 177 177 185 1185 SpectrAlert Advance Diagrams II Wall-Mount Horn Strobes EM erproof Back Box Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) PHK"t - 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Red, Metal Weatherproof Back Box "S-WBBW White, Metal Weatherproof Back Box Notes: Add "-P' to model number for plain housing (no "FIRE" marking on cover), e.g., P2tRK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPtN. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd' refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 Product specth .. @2O cat ens subtect tot2 r. SycharrstemSenso ge without notice, vet systemsensor.cern SENSOR Phone' 800-SENSOR2 9 Fax: 630-377-6495 tar current product information, including the tatest version at this data sheet. AVDS01201 • 31t2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 1653J 188 Page 1 of 1 CATEGORY: f,125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.KireyevhoneywelI.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P21R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffi in,icating indoor or outdoor use, or may be followed by suffix 'P' for plain housing with n .ng. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires 04 8 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division