HomeMy WebLinkAbout2505 GATEWAY RD; ; FPC2017-0324; PermitPERMIT REPORT 4btyof Carlsbad Print Date: 05/27/2021 Permit No: FPC2017-0324 Job Address: 2505 GATEWAY RD, CARLSBAD, CA 92009-1742 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel U: 2132601100 Track U: Applied: 11/06/2017 Valuation: $4,621,999.48 Lot U: Issued: 12/01/2017 Occupancy Group: Project U: Finaled Close Out: 05/13/2021 #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check #: Final Inspection: Project Title: - Description: VIASAT CAFE AND CONFERENCE CENTER SHELL -FIRE ALARM (NEW) Applicant: FPContractor: JJJ ENTERPRISES THE STEINHILBER CORPORATION SALOMON GOMEZ 533 S VINEWOOD ST 115 MARKET PL ESCONDIDO, CA 92029-1924 ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 (760) 747-3050 x216 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov mpmrmp Elmnapposm FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS FPC20I7-0324 2505 GATEWAY RD VIASAT CAFE AND CONFERENCE CENTER SHELL - FIRE ALARM (NEW) 2132601100 11/6/2017 FPC20I 7-0324 VIASAT CAFE AND CONFERENCE CENTER SHELL 2505 GATEWAY ROAD CARLSBAD, CA 92009 FIRE ALARM SYSTEM (DATA-SHEETS Li BILL OF MATERIALS NOTIFIER NFS-320 FIRE ALARM CONTROL PANEL W/UDACT-2 UNIVERSAL DIGITAL COMMUNICATOR CSFM# 7165-0028:0243 NOTIFIER FDU-80 LIQUID CRYSTAL REMOTE FIRE ANNUNCIATOR CSFM# 7120-0028:0209 DSC 3G3070-CF 3G UNIVERSAL WIRELESS COMMERCIAL FIRE ALARM COMMUNICATOR CSFM# 7300-1273:0140 NOTIFIER NBG-12LX ADDRESSABLE MANUAL PULL STATION CSFM# 7150-0028:0199 - - NOTIFIER FSP-851. INTELLIGENT SMOKE DETECTOR WITH B71OLP BASE CSFM# 7272-0028:0206, 7300-0028:0173(BASE) NOTIFIER FST-851 THERMAL HEAT DETECTOR W/B71OLP BASE CSFM# 7272-0028:0196, 7300-0028:0173(BASE) NOTIFIER 302 SERIES RATE ANTICIPATION HEAT DETECTOR CSE'M# 7270-0021:0001 NOTIFIER DNR INNOVAIRPLEX DUCT SMOKE DETECTOR W/FSP-852. CSFM# 3242-1653:0209 NOTIFIER FMM-101 ADDRESSABLE MONITOR MODULES CSFM# 7300-0028:0219 NOTIFIER FRM-1 ADDRESSABLE RELAY AND CONTROL MODULES CSFM# 7300-0028:0219 DN-71 12:G NFS-320(E) NOTI Fl ER® Intelligent Addressable 0 Fire Alarm System by Honeywell __ General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement. The NFS-320's modular design makes system planning easier. The panel can be configured with just a few devices for small building applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. For installations using NFS-320C, an optional ACM Series annunciator can be mounted in the same cabinet (up to 48 zones/points, order separately; see DN-60085). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless called out with a version-specific "R", "C" or "E" at the end of the part number, 'WFS-320" refers to models NFS-320, NFS-320R, NFS-320C, and NFS-320E. Features Certified for seismic applications when used with the appro- priate seismic mounting kit. Approved for Marine applications when used with listed com- patible equipment (see DN-60688). One isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7. Up to 159 detectors (any mix of ion, photo, thermal, or multi- sensor) and 159 modules (Addressable pull stations, nor- mally open contact devices, two-wire smoke, notification, or relay). 318 devices maximum. Standard 80-character display. Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC, ONYXWorks, NFS-3030, NFS-640, and NCA). - Standard network for up to 103 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCA-2, DVC, ONYX- Works, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP- 300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC is used in network paging. 6.0 A power supply with four Class NB built-in Notification Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. Autoprogramming and Walk Test reports. Optional universal 318-point DACT. 80-character remote annunciators (up to 32). EIA-485 annunciators, including custom graphics. Printer interface (80-column and 40-column printers). History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. NFS-320 Alarm Verification selection per point, with tally. Presignal/Positive Alarm Sequence (PAS). Silence inhibit and Auto Silence timer options. NAC coding functions: - March time. - Temporal. - California two-stage coding. - Canadian two-stage. - Strobe synchronization. Field-programmable on panel or on PC, with VeriFire® Tools program check, compare, simulate. Full QWERTY keypad. Battery charger supports 18 - 200 AH batteries. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Automatic time control functions, with holiday exceptions. Extensive, built-in transient protection. Powerful Boolean logic equations. FLASHSCAN® INTELLIGENT FEATURES Poll up to 318 devices in less than two seconds. Activate up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - nine levels. Pre-alarm ONYX intelligent sensing - nine levels. Day/Night automatic sensitivity adjustment. Sensitivity windows: - Ion - 0.5 to 2.5%/foot obscuration. - Photo - 0.5 to 2.35%/foot obscuration. - Laser (VIEW®) - 0.02 to 2.0%/toot obscuration. - Acclimate® PlusTM - 0.5 to 4.0%/foot obscuration. - IntelliQuad - 1.0 to 4.0%/foot obscuration. - lntelliQuadTM PLUS - 1.0 to 4.0%/foot obscuration Drift compensation (U.S. Patent 5,764,142). DN-7112G.119/2O11—Page 1 016 2048 annunciator/control points I:fl: F 11 00 ACM-BR ACM/AEM-24AT LDM-32 Relay Control LED Annunciator Custom Graphics EIA-485 EtA -485 NFS-320 Degraded mode - in the unlikely event that the NFS-320's primary microprocessor fails, FlashScan detectors revert to degraded operation and can activate the control panel's NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. FSL-751 VIEW (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY Revolutionary spot laser design. Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the fire location. No moving parts to fail or filters to change. Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FA PT-851 ACCLIMATE® PL US TM LOW-PROFILE INTELLIGENT MULTI-SENSOR Detector automatically adjusts sensitivity levels without oper- ator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. FlashScan or CLIP (classic") mode compatible. Low-temperature warning signal at 40°F ± 5°F (4.44°C ± 2.77°C). FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. Six sensitivity levels. FCO-851 INTELLIQUA DIM PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR Detects all four major elements of a fire. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. Six sensitivity levels. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). Low-pressure CO2 listed. VOICE FEATURES Integrates with FireVoice-25/50 Series (see DN-7004). Integrates via serial connection with FireVoice-25/50ZS Series (see DN-7003). HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 A POWER SUPPLY (6.0 A IN ALARM) 120 VAC (NFS-320/NFS-320C); 240 VAC (NFS-320E). Displays battery current/voltage on panel (with display). Up to 32 Remote Displays FDU 80 LCD2-80 LCD20 SLC Intelligent - - - )ICE - - FSC-851 1nte1110uadr FAPT-851 Acclimate Plus" FSL-751 RashScareB viswe FSP-851 FlashScarht photo etc. NBG-12LX FMM-1 FRM-1 XP6/10 I/O Modules IDC Relay Contact Sample System I EIA-2321C~1 ~1l1\ Options PAN Series Printer Page 2of6—DN-7112:G° 12119/2011 318 point UDACT Dual phone lines to Central Station FlashScan, Exclusive World-Leading Detector Protocol At the heart of the NFS-320 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashS- can is an all-digital protocol that gives superior precision and high noise immunity. In addition to providing quick identification of an active input device, this new protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS-320 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS-320 with industry-leading smoke detection capability. These complex algorithms require many calculations on each reading of each detector, and are made possible by the high- speed microcomputer used by the NFS-320. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Maintenance Warnings: When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indica- tive of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre- alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre-alarm operation can be latching or self- restoring, and can be used to activate special control functions. Self-Optimizing Pre-Alarm: Each detector may be set for "Self- Optimizing" pre-alarm, In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to con- sider readings from nearby sensors in making alarm or pre_ alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram. This timesaving feature is a special software rou- tine. The FACP "learns" what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installation, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS-320, like all NOTIFIER intelligent panels, has the exclusive feature of pro- gram creation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS-320 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per- point segments, while the NFS-320 simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools is an off line programming and test utility that can greatly reduce installation programming time, and increase con- fidence in the site-specific software. It is Windows®-based and provides technologically advanced capabilities to aid the installer. The installer may create the entire program for the NFS-320 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS-320's flexible system design. Wiring: When designing the cabinet layout, consider separation of power-limited and non-power-limited wiring as discussed in the NFS -320 Installation Manual. It is critical that all mounting holes of the NFS-320 are secured with a screw or standoff to ensure continuity of Earth Ground. Networking: If networking two or more control panels, each unit requires a Network Control Module or High-Speed Network Control Module (HS-NCM can support two nodes; see "Net- working Options" on page 4). These modules can be installed in any option board position (see manual), and additional option boards can be mounted in front of them. KDM.R2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout). 12 LED indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Dis- abled; Control Active; Abort; Pre-Discharge; Discharge. Keypad Switch Controls: Acknowledge/Scroll Display; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED back- light. Ordering Information "Configuration Guidelines" on page 3 "Networking Options" on page 4 "Auxiliary Power Supplies and Batteries" on page 4 "Audio Options" on page 4 "Compatible Devices, ElA-232 Ports" on page 4 "Compatible Devices, EIA-485 Ports" on page 4 "Compatible Intelligent Devices" on page 4 "Enclosures, Chassis, and Dress Plates" on page 5 "Other Options" on page 5 CONFIGURATION GUIDELINES The NFS-320 system ships assembled; description and some options follow. See "Enclosures, Chassis, and Dress Plates" on page 5 for information about mounting peripherals. NOTE: Stand-alone and network systems require a main display. On stand-alone systems, the panel's keypad provides the required display. On network systems (two or more networked fire panel nodes), at least one NCA-2, NCS, or ONYX Works annunciation device is required. (in FS 320: The standard, factory-assembled NFS-320 systii cludes the following components: one control panel mounted) on chassis (120 V operation - ships with grounding cable, bat-) tery interconnect cables, and document kit); includes integral; power supply mounted to the main circuit board; one primary isplayKDM-R2keyp4d/disptay;anci,pnecabinet,forsurfaceor DN-7112:G.12/19/2011—Page 3016 -flh mounti Plbitries separatibiàTtw) option boards may be mounted inside the NFS-320 cabinef,) (additional option boards can be used in remote cabinets.) NFS-320R: Same as NFS-320 above, but in red enclosure. NFS-320C: Based on NFS-320 above. NFS-320C supports installation of an optional ACM-series annunciator in the same cabinet. UL- and ULC-listed. NOTE: For additional information on NFS-320C, see DN-60085. NFS-320E: Same as NFS-320 above, but with 240 V operation. TR-320: Trim ring for the NFS-320 cabinet. NETWORKING OPTIONS NCM-W, NCM-F: Standard Network Communications Modules. Wire and multi-mode fiber versions available. See DN-6861. HS-NCM-W/MF/SFIWMFIWSF/MFSF: High-speed network communications modules. Wire, single-mode fiber, multi-mode fiber, and media conversion models are available. See ON- 60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN-6971. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. AUXILIARY POWER SUPPLIES AND BATTERIES ACPS-610: 6.0 A or 10 A addressable charging power supply. See ON-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and trans- fer relay, and overcurrent protection. Mounts on two of four posi- tions on a CHS-4L or CHS-4 chassis. See DN-5952. FCPS-24S6/S8: Remote 6 A and 8 A power supplies with bat- tery charger. See ON-6927. BAT Series: Batteries. NFS-320 uses two 12 volt, 18 to 200 AH batteries. See DN-6933. AUDIO OPTIONS NFV-25/50: 25 watt, 25 yAMS, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, and single-/dualchannel Class A or Class B speaker circuits. See DN-7004. NFV-25/50DA: Single channel, 25 Watt, 25 VRMS, emergency voice evacuation panel. See DN-60048. NFV-25/50DAZS: Single channel, 25 Watt, 25 Vrms, emergency voice evacuation panel. Can be automatically activated via the Zone System serial communication link from the NFV-25/50ZS. See ON-60049. NFV-25/50Z5: 25 watt, 25 Vrms, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, zone splitter module (ACC-ZSM), zone page module with keypad (ACC-ZPMK). See DN-7003 NFV-25/50ZST: 25 watt, 25 Vrms, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, zone splitter module (ACC-ZSM), zone page module with keypad (ACC-ZPMK). See ON-60337. COMPATIBLE DEVICES, EIA -232 PORTS PRN-6: 80-column printer. See DN-6956. V54095/5: Printer, 40-column, 24 V. Mounted in external back- box. See ON-3260. DPI-232: Direct Panel Interface, specialized modem for extend- ing serial data links to remotely located FACPs and/or peripher- als; mount on NFS-320 chassis. See DN-6870. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by pow- ered-up switch selection) by point to be red, green, or yellow; the Trouble LED is always yellow. See ON-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See ON-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See ON-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. LCD-80: ACS mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See LCD-80/-80TM (ON-3 198). FDU-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-6820. LCD2-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-60548. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32; remote custom driver modules. See ON-0551. SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers SCS-8L, SCE-8L; eight (expandable to 16) circuits. See ON- 48 18. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit; mount on NFS-320 chassis or remotely. See ON-6860. UDACT: Universal Digital Alarm Communicator Transmitter, 636 channel. See ON-4867. UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See ON-60686. UZC-256: Programmable Universal Zone Coder provides posi- tive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from IBM®-compatible PCs (requires optional programming kit). Mounts in BB-UZC. See ON-3404. COMPATIBLE INTELLIGENT DEVICES BEAMHK: Heating kit for transmitter/receiver unit of FSB-200(S) below. See DN-6985. BEAMHRK: Heating kit for use with the reflector of FSB-200(S) below. See DN-6985. BEAMLRK: Long-range accessory kit, FSB-200(S) below. See DN-6985. BEAMMRK: Multi-mount kit, FSB-200(S) below. See DN-6985. BEAMSMK: Surface-mount kit, FSB-200(S) below. See ON- 6985. FSB-200: Intelligent beam smoke detector. See ON-6985. FSB-200S: Intelligent beam smoke detector with integral sensi- tivity test. See DN-6985 FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria Detec- tor. See ON-60412. FCO-851: FlashScan IntelliQuad PLUS Advanced Multi-Criteria Fire/CO Detector. See ON-60689. FSI-851: Low-profile FlashScan ionization detector. See ON- 6934. Page 4 of 6-DN-7112:G • 12/19/2011 FSP-851: Low-profile FlashScan photoelectric detector. See DN-6935. FSP-851T: Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6935. FSP-851 R: Remote-test capable photoelectric detector for use with DNR(W) duct detector housings. See DN-6935. FST-851: FlashScan thermal detector 135°F (570C). See DN-6936. FST-851R: FlashScan thermal detector 135°F (57°C) with rate- of-rise. See ON-6936. FST-851H: FlashScan 190°F (88°C) high-temperature thermal detector. See DN-6936. FAPT-851: FlashScan Acclimate Plus low-profile multi-sensor detector. See DN-6937. FSL-751: FlashScan VIEW laser photo detector. See DN-6886. DNR: InnovairFIex low-flow non-relay duct-detector housing (order FSP-851R separately). Replaces FSD-751PLIFSD- 751 RIP L. See DN-60429. DNRW: Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. 6224B1: Isolator base for low-profile detectors. See DN-60054. B21OLP: Low-profile base. Standard U.S. style. Replaces B71OLP. See DN-60054. B501: European-style, 4" (10.16 cm) base. See DN-60054. B200S: Intelligent programmable sounder base, capable of pro- ducing a variety of tone patterns including ANSI Temporal 3. Compatible with sychronization protocol. See DN-60054. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN-60054. FMM-1: FlashScan monitor module. See DN-6 720. FDM-1: FlashScan dual monitor module. See DN-6 720. FZM-1: FlashScan two-wire detector monitor module. See DN- 6 720. FMM-101: FlashScan miniature monitor module. See DN-6 720. FCM-1: FlashScan NAC control module. See DN-6724. FCM-1-REL: FlashScan releasing control module. See ON- 60390. FRM-1: FlashScan relay module. See DN-6 724. FDRM-1: FlashScan dual monitor/dual relay module. See ON- 60709. NBG-12LX: Manual pull station, addressable. See DN-6 726. ISO-X: Isolator module. See DN-2243. XP6-C: FlashScan six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan six-zone interface module; connects intelli- gent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay (Form-C) control module. See ON- 6926. XP10-M: FlashScan ten-input monitor module. See DN-6923. ENCLOSURES, CHASSIS, AND DRESS PLATES MARINE-EQ System: Protects equipment in shipboard and waterfront applications. For a full list of required and optional equipment, see DN-60688. BB-UZC: Backbox for housing the UZC-256. Required for NFS- 320 applications. Black. For red, order BB-UZC-R. NFS-LBB: Battery Box (required for batteries larger than 26 AH). NFS-LBBR: Same as above, but red. SElSKlT-320/B26: Seismic mounting kit. Required for seismic- certified applications with NFS-320 and BB-26. Includes battery bracket for two 26 AH batteries. SEISKIT-BB25: Seismic mounting kit for the BB-25. Includes battery bracket for two 26 AH batteries. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. SElSKlT-PS/2/4: Seismic mounting kit for the FCPS-24S6/S8 and CAB-PSi. Includes battery bracket for two 7 AH or 12 AH batteries. OTHER OPTIONS 411: Slave Digital Alarm Communicator. See DN-6619. 411UDAC: Digital Alarm Communicator. See DN-6746. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Con- nects to primary and secondary DACT telephone output ports for internet communications over customer-provided ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPSPLT: V-adaptor option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red. For Black order IPENC-B. IPGSM-DP: Internet and Digital Cellular Fire Alarm Communi- cator. Provides selectable configurable paths: cellular only, IP only, or I primary with cellular backup. Connects to the primary and secondary ports of a DACT. Replaces IPGSM-COM. See DH-60695. VerlFlre-TCD: VeriFire Tools CD-ROM. Contains programming software for the ONYX Series. Includes local panel connection cable. See DN-6871. VerlFlreUG-TCD: VeriFire Tools upgrade software. NFS-320-RB: Replacement CPU. NOTE: Keypad must be removed before shipping old unit out for repair. NFS-320-RBE: Replacement CPU, Export. NFS-320-RBC-FR: Replacement CPU, Canadian French. NFS-320-RB-PO: Replacement CPU, Portuguese. NFS-320-RB-POE: Replacement CPU, Export, Portu- guese. NFS-320-RB-SP: Replacement CPU, Spanish. NFS-320-RB-SPE: Replacement CPU, Export, Spanish. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. DN-7112:G•12/19/2011 -Page 50f 6 SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits . 1 Intelligent detectors .........................................................159 Addressable monitor/control modules ..............................159 Programmable internal hardware and output circuits ..........4 Programmable software zones...........................................99 Special programming zones...............................................14 LCD annunciators per NFS-320/-320E .............................32 ACS annunciators per NFS-320/-320E .......................32 addresses x 64 points Specifications Primary input power - NFS-320: 120 VAC, 50/60 Hz, 5.0 A. - NFS-320E: 220/240 VAC, 50/60 Hz, 2.5 A. Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 A of available power. This is shared by all internal circuits. Standard notification circuits (4): 1.5 A each. Resettable regulated 24V power: 1.25 A. Two non-resettable regulated 24V power outputs: —1.25 A. - 0.50 A. Non-resettable 5V power: 0.15 A. Battery charger range: 18 AH —200 AH. Use separate cabi- net for batteries over 26 AH. Float rate: 27.6 V. Cabinet Specifications NFS-320 cabinet dimensions: Backbox: 18.12 in. (46.025 cm) width; 18.12 in. (46.025 cm) height; 5.81 in. (14.76 cm) depth. Door: 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm) height; 0.75 in. (1.905 cm) depth. Trim ring: Molding width is 0.905 in. (2.299 cm). Shipping weight (without batteries): 36.15 lb. (16.4 kg). Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F. Agency Listings and Approvals The listings and approvals below apply to the basic NFS-320 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL Listed: S635. ULC Listed: S635 (NFS-320C only, excludes IPDACT). FM Approved. CSFM: 7165-0028:0243, MEA: 128-07-E. FDNY: COA#6085. City of Chicago. NOTE: For additional information on UL- and ULC-listed model NFS-320C, see DN-60085. For information on NFS-320SYS, see DN-60637. When used with the MARINE-EQ, appropriate seismic bracket, and marine approved devices, these ONYX fire alarm control panels are approved by the following agencies: US Coast Guard: 161.002/50/0 (Standard 46 CFR). Lloyd's Register: 11/600013 (ENV 3 category). Standards The NFS-320 complies with the following UL Standards and NFPA 72, IBC, and CBC Fire Alarm Systems requirements: UL 864 (Fire). UL 1076 (Burglary). LOCAL (Automatic, Manual, Waterflow and Sprinkler Super- visory). AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). Not applicable for FM. CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires UDACT). EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Net- work). IBC 2000, IBC 2003, IBC 2006, IBC2009 (Seismic). CBC 2007 (Seismic). N0TI.FIRE•NET, lnteIIIOuad, and 0NYXWorks'' are trademarks; and Acclimate® PlusiM, FlashScan®, NOTIFIER®, ONYX®, VerlFlre®, and VIEW® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. IBM® is a registered trademark of IBM Corporation. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so ooi We try to keep our product information up-to-date and accurate. :b We cannot cover all specific applications or anticipate all requirements. ENSINEMINC & MNUMC1URINB All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 6of6—DN-7112:G• 12/19/2011 DN-60686:A1 0 NOTIFIER® Communicator Transmitter by Honeywell /i\iiiiiiir1Tfrd DJ General , Oil U DACT.2 Universal Digital Alarm The Universal Digital Alarm Communicator Transmitter (UDACT- 2) is designed for use on Notifier Fire Alarm Control Panels and on the NCA-2 Network Control Annunciator. When used in con- junction with the NCA-2 network control annunciator, the UDACT-2 can report the status of all control panels on NOTl.FlRE.NETTM. The UDACT-2 transmits system status to UL listed Central Station Receivers via the public switched tele- phone network. The UDACT-2 can be installed in the panel cab- inet or remotely in a separate enclosure. NOTE: The UDACT-2 can also be used with legacy panels. Please refer to the UDACT-2 manual for more information. The UDACT-2 upload/download programming and firmware updates are accomplished with VeriFire Tools. Refer to the Pro- gramming Section for further details. The UDACT-2 is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Ott-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT-2 is capable of transmitting all of the zone and point sta- tus associated with each panel. When the UDACT-2 is used with the NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Report- ing may be in the form of points or zones (refer to the UDACT-2 manual for specific reporting parameters). Points transmitted may be programmed for a variety of types, including fire, water- flow, supervisory, etc. NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID format. See chart on page 2 for compatible receivers. Features Programmable with VeriFire Tools version 6.60 or higher, allowing the UDACT-2 programming to be uploaded/down- loaded and saved. Maximum of 14 point trouble messages transmitted per hour. Dual phone lines with line voltage detect. Compact in size: 6.75" x 4.25" (17.145 x 10.795 cm). USB port for upload/download programming. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8RB or UBS-1 B/R). Communicates vital system status including: - Independent zone fire alarm. - Independent zone non-fire alarm. - Independent zone trouble. - Independent zone supervisory. - AC (mains) Power Loss (programmable). - Low Battery and Earth Fault. - System Off-Normal. - 12 or 24 hour test signal. - Abnormal Test Signal per new UL requirements. - EIA-485 Communication Bus Failure. Annunciation of UDACT-2 Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kis- sotf, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. U DACT-2 Open Collector relay driver for Total Communications Failure or UDACT-2 trouble. Real-time clock. Extensive transient protection. EIA-485 interface to host panel. Programming The UDACT-2 programming is created and downloaded using VeriFire Tools. This enables the unit to be programmed prior to installation, be easily modified, and saved either online or offline. A printed report with point or zone information can be generated from VeriFire Tools for an ONYX Series panel or net- work annunciator. The point report consists of the central station point address, ACS point, ACS point function, panel label, panel point, type code, custom and extended label, alarm verification, walktest participation, presignal, and PAS information. The zone report consists of a grid with the central station point address, ACS point address, source, ACS point function, custom label and panel label. This report may be sent to the Central Station for their records. VeriFire Tools also supports upgrading the UDACT-2 operating firmware. DN-60686:A1 • 4/2/12 - Page 1 of 2 Communication Formats Ademco Contact ID 4+2 Standard SlA NOTE: Ademco Contact ID must be used for independent zone reporting. Type Mode Feature Ademco Contact ID format - only Use Type Mode to identify reports to Central Station as: Fire Alarm Burglary Supervisory 24 hour Non-Burglary Pull Station High Temperature Heat Detector Low Temperature Waterflow Low Water Pressure Duct Detector Low Water Level Flame Sensor Pump Failure Smoke Zone Electrical Specifications Standby current: 40 mA. Current while communicating: 75 mA. Maximum current while communicating and with open collector output activated: 100 mA. Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULIULC Listed: S635 FM Approved CSFMT7165:0028024) (NFS2-640/320), 7165-0028:0224 (NFS2-3030) FDNY: COA#6085, COA#6098 Ordering Information (UDACT-2: Digital Alarm Communicator Tri—nsmitte—F) (Includes operating and programmingJstructions, mountin MCBL-7: DACT phone cord, 7 ft (2.13 m) long (two required). ABS-8RB: Metal enclosure for externally mounting UDACT-2 up to 6,000 ft./1828.8 m from host FACP. 9.94" H x 4.63" W x 2.50" D (cm: 25.248 H x 11.760 W x 6.350 D). UBS-1B: Metal enclosure with solid door, Black. UBS-1BR: Metal enclosure with solid door, Red. R-1 OE: SPDT Form-C relay. Contacts rated for 10 A @ 115 VAC. Connects to open collector relay driver. R-20E: DPDT Two Form-C relays. Contacts rated for 10A @ 115 VAC. Connects to open collector relay driver. FBD-1: Ferrite bead kit. Use for remote mounting only. UL Listed Receivers The chart below shows UL listed receivers compatible with the UDACT-2. A check in the protocol column indicates the receiver supports that protocol. Receiver 4+2 Standard 1800/2300 Ademco Contact ID SIA Ademco 685 (1) V Ademco MX8000 (2) V V Silent Knight 9500 (3) Silent Knight 9800 (4) V V V FBI CP220FB (5) V Osborne Hoffman 2000E (6) V v Radionics 6600 (7) V V SurGard MLR2 (8) V SurGard System III (9) ,/ V SurGard MLR-2000 (10) With 685-8 Line Card with Rev 4.4d software With 124060V206B and 124063 Line Card Rev B With version V2.4 Receiver & 126047 Line Card Rev G With 124077V2.00 Receiver &126047 Line Card Rev M With software V3.9 With V.7301 Receiver S/W With 01.01.03 Receiver S/W & Line Card 01.01.03 With software V1.86 With sotware V1.72 With DSP4016 and V1.6 Line Card NOTl.FlRE.NET is a trademark and Notitier® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING S MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60686:Al • 4/2/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION If OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7165-0028:0243) Page 1 of 4 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models NFS2-640, NFS-320/C (R), and NFS-320SYS fire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), manual, automatic, waterfowl and sprinkler supervisory services. Also suitable for releasing service, Process Management and Emergency Voice/Alarm communication System . Model numbers may be followed by an "R" suffix representing the enclosure color being red. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ACM-8R, -16AT, -32A, -24AT, -48A; Annunciator Control Modules ACPS-6 10, AMPS-24-1 Addressable power supply/charger ADP-4B, -A4, -1, -2, DP-DlSP2; Dress Panel AEM-16AT, -32A, -24AT, -48A; Annunciator Expander Modules AFM-16A, -16AT, -32A; Annunciator Fixed Modules AKS-1 B; Annunciator Key Switch APS2-6R; Power supply BB-100, -200, NFS-LBB/-LBBR; Battery Boxes BGRA-SCS, BGRB-SCS; Smoke Control Station BMP-1; Blank Module BP-4, BP24; Battery Dress Plates CAB-3/4 Series; Enclosure CAB-RP, CAB-RPR; Cabinets CEF-SCS; Smoke Control Station CHS-4, CHS-4N, CHS-4L; Chassis CPU2-640, CPU-3205Y5; CPU Board CRT-2; Display Terminal DP-1B; Blank Panel DPA-1A4/1/2, DP-DlSP2; Dress Panel DPI-232-1 Panel Interface DR-A4, DR-A413, DR-A4BR, DR-A4R; Door Assembly DR-M4, DR-M4B, DR-AA4BR, DR-AA4R; Door Assembly DR-B3F; Door Assembly DR-134, DR-13413, DR-13413R, DR-134R; Door Assembly DR-C4, DR-C4B, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D413, DR-D4BR, DR-D4R; Door Assembly *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (June 30, 2!) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 2 of 4 EQ Series; Cabinets EQBB-134, EQBB-C4, EQBB-D4; Backbox Assembly EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-1, FCM-1-REL; Releasing Control Module FCPS-2456, -24S8; Field Charger/Power Supply FDM-1; Dual Monitor Module FDRM-1 Multiple Module with two Relay Outputs FDU-801-80G; Remote Annunciator FlRSTVtSlON-LCD/ENC; Interactive Firefighters display/enclosure FRM-1; Relay Module FTM-1; Control Module FZM-1, FMM-1, FMM-101; Monitor Modules HS-NCM-WI-MF/-SF/-WMF/-WSF/-MSSF; High Speed Network Control Modules IPDACT-2/-2UD; IP Fire Alarm Communicator ISO-X; Isolator Module KAPS-24, CPS-24; Power Supply KDM-R2; Keyboard Display Module LCD-80, -160; Annunciators LCD-80TM; Annunciator Terminal Module LCD LCD2-80; Remote Annunciator LDM-32/-E32/-R32; Lamp Driver Module LEM-3201ELEM-320; Loop Expander Module NBG-12LRA; Agent Releasing Abort Station NBG-12LX; Addressable Manual Pull Station NCA, NCA-2; Network Communication Annunciator NCM-W, -F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station NCS5-W-ONYX, NCS5-F-ONYX; Network Control Station NFS-LBB/NFS-LBBR; Battery Box/Red NFS-320SYS; Chassis NFV-25/50, NFV-25/50Z5/ZST; Voice Evacuation Control Panels N FV-25/5ODA, NFV-25/50DAZS; Distributed Audio Panels ONYXWorks-EW/-NW-/N F/-HNW/-HNMF/-H NSFI-TS/-EW-TS/-N F-TS/-HW-TS/ -HNMFT/-HNSFT/-HNWT; PC workstation for NOTl.FlRE.NET, Wire/Fiber/ with Touch screen monitors PRN-6; Printer RKS-S; Remote Security Key Switch RPT-W, -485W; Repeater Wire RPT-F; Repeater Fiber RPT -485FW; Repeater Fiber/Wire RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-AA4R; Backbox Assembly SBB-134, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly SBB-D4, SBB-D4R; Backbox Assembly *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 3 of 4 SCE-8; Smoke Control Expander SCS-8L; Smoke Control Lamp Driver Station SCE-8L; Smoke Control Expander Lamp SCS-8; Smoke Control Station STS-1; Security Tamper Switch TM-4; Transmitter Module TR-A4/-B3NI-B4/-C4/-D3NI-D4; Trim Ring UDACT, UDACT-2; Universal DACT UZC-256; Universal Zone Coder VP-213; Dress Panel XPS-C/-M; Transponder Modules XP6-C; Supervised Control Modules XP6-MA; Six Zone Interface Modules XP6-R; Six Relay Control Modules XP10-M(A); Ten Input Monitor Modules XPM-8L; Transponder Monitor Modules The following models are intended for use on NFS2-640 only: AA-30, -100, -120; Amplifiers ACT-1, -2, -4, -25, -70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4R/-D4/-D4R; Door Assemblies AMG-E; Audio Message Generator AVL-i; Audio Voice Link BDA-25V/-70V; Backup Digital Audio Amplifiers CHS2-M2, CA-1, CA-2; Chassis CMlC-1, CMIC-RP; Microphone Assembly DAA-50251-5070; Digital Audio Amplifiers DAA-5025F/DAA-5025SF; Digital Audio Amplifiers DAA-5070F/DAA-5070SF; Digital Audio Amplifiers, Fiber Mode DAA-75 Series; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-7525SF; Digital Audio Amplifiers DAA2-50251-5070/-7525; Digital Audio Amplifiers DAX-3525/-3570/-5025/-5070; Digital Audio Amplifiers DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DVC; Digital Voice Command DVC-EM/-EMF/-EMSF; Digital Voice Command Extended Memory Module DVC-RPU; Remote Paging Unit FFT-7, -7S; Fire Fighter's Telephone FHS; Fireman's Handset FPJ; Fireman's Phone Jack RM-1, RM-1SA; Remote Microphone *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0028:0243 Page 4 of 4 TELH-1; Telephone Assembly XPIQ; Transponder Quad Intelligent Audio INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Label APPROVAL: Listed as fire alarm control units suitable for use in high-rise applications when used in conjunction with separately listed compatible initiating and indicating devices. *Control units may be used with Notifier's First Command NFC-50/100 emergency voice evacuation panals (CSFM # 6911-0028:0265). This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 Seconds. 2. Combined with 7170-028:244 *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6820:13 • D-123 80 Character Liquid Crystal Display - by Honeywell fi\i1iluIirfirJ1 General The FDU-80 is a compact, cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the NOTIFIER Fire- Warden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and displays complete system point status information. Up to 32 FDU-80s may be connected onto the ElA-485 termi- nal port of each FACP. The FDU-80 requires no programming, which saves time during system commissioning. Features 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced. No programming necessary - FDU-80 connects to the ter- minal porton the FACP. Displays device type identifiers, individual point alarm, trou- ble or supervisory, zone and custom alpha labels. Time-and-date display field. Aesthetically pleasing design. May be powered from the host FACP or by remote power supply (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from the FACP. Local piezo sounder with alarm and trouble resound. Semi-flush mounts to 2.188° (5.556 cm) minimum deep, three-gang electrical box (NOTIFIER PN 10103) or three- gangable electrical switchbox. Surface-mounts to NOTIFIER PN SBB-3 surface backbox. Operation The FDU-80 annunciator provides the FACP with point annun- ciation with full display text on an 80-character LCD display. The FDU-80 also provides an array of LEDs to indicate system status, and includes control switches for remote control of criti- cal system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188° (5.556 cm) minimum deep, three-gang electrical box or three-gang- able electrical switchboxes. Alternately, an S1313-3 surface backbox is available for surface-mount applications. FLE ALARM ANNCTO T .d 68201du8jpg Ordering Information FDU-80: 80 character, backlit, LCD Fire Annunctor with co) trol switches for remote control of system functions, and key:) çwitch lock.) FDU-80C: ULC-listed version; see DN-60573 for details. 10103: Three-gang electrical box, minimum 2.188° (5.556 cm) deep, for semi-flush mount applications. SBB-3: Three-gang surface backbox for surface-mount appli- cations. Agency Listings And Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 MEA Listed: 245-00-E FDNY: COA#6038 M: 7120-0609-), FM Approved NOTE: For ULC-listed version, see DN-60573. DN-6520:B.05/17/2010—Page 1 of 2 NOTIFIER® is registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MSINfERINI & MIUFAC1URINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6820:B • 05/17/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION MARKING: APPROVAL: NOTE: (7120-O028:02O9 Page 1 of 1 7120 -- ANNUNCIATORS NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com Models FDU-80 and *FDu..80G remote fire annunciators. Units are compact 80-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as annunciators for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. Rev. 10-03-06 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (June 3O,) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 3G technology from DSC! Dec From Tyco Security Products Features That Make a Difference: Uses HSPA (3G) network for high-speed, reliable and low- cost communications to an IF receiver Automatically switches to 2G (EDGE/GPRS) if 3G service is not available Compatible with control panels that communicate using Contact ID or SIA (300 baud) formats Full event reporting 4 on-board inputs with NC, NO or SEOL supervision 4 on-board outputs (open collector) Activation and initialization via automated telephone activation system (VRU), web-user or mobile interface provided by C24 Communications View communicator status directly from your mobile phone to support on-site or remote troubleshooting Compatible with Sur-Gard® System l-IP/11/111/lV/5 monitoring station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery UL 864 listed CSFM listed The 3G401OCF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System l-IP/lI/lll/lVt5). The 3G401OCF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panes that communicate using the Contact ID or SIA (300 baud) format. The 3G401OCF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 an 2013 Editions. It can be used in Fire Monitoring applications as a single communications technIogy, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or 1 hour (NFPA72 2013) of t1e failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the ntegrity of each communication path and failure of any communications path shall be annunciated at tie supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The 3G401OCF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the 3G401 OCF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. In instances where the control panel does not support Contact ID or SIA (300 baud), the 3G401OCF has inputs pre-set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IP linecard of the monitoring station receiver (Sur-Gard® System I-IP/I1/1I1/IV/5). Specifications Dimensions ................. Input Voltage................ Current Draw .............. Operating Environment Weight......................... 11-1/2 x 10" x3" (290 mm x 254 mm x 75 mm) 120 VAC 200 mA (standby) 400 mA (transmitting) 320 to 120° F (00 to 49° C) 12.8 lbs (5.8 kg) Optional Acessories Model Description GS-1 5ANT 15 ft extension antenna (internal use) GS-25ANT 25 ft extension antenna (internal/external use) GS-50ANT 50 ft extension antenna (internal/external use) Dec From Tyco Security Products Activating & Initializing the Unit Activating and initializing the 3G401 00F can be done using the automated telephone activation system (JRU), mobile interface or web-user interface provided by 024 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the 3G40100F requires use of the 4MB (NFPA72 2010) or 500kB (NFPA72 2013) rate plans to support the supervision requirements. C24 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost allocated to maintenance. C24 0 0 0 UL Listing The 3G40100F is UL listed under File S4019, Listing guide UOXX, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the 3G40100F will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013 guidelines the 3G40100F will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the 3G40100F will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The 3G401 OCF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: (G401OCF-US ..........Universal Wireless Commercial Fire Alarm Communicator (U.S. Model/SIM Card Included) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION lob OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-1273:0161) Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Security ControIs95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: Model 3G4010CF RF Communicator (GSM-GPRS/3G) signaling device. It is intended for use as a standalone communication technology (standalone unit). It may also be used as a backup communication technology in conjunction with a DACT. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 V, 50/60 Hz, 0.3 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as communicator signaling device for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. 06-03-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (4une 30, 2018) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6726:D • H-240 T1FIER Addressable Manual Pull Station by Honeywell t-rt1 The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4 (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on CLIP protocol loops. Up to 159 NBG-12LX stations per loop on FlashScan® pro- tocol loops. Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location pos:1 %N UtLDOV* The NBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4 (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4 (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 on FlashScan® systems, 1 —99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual statons shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or DN-6726:D • 4/13/2012 - Page 1 of 2 4 (10. 16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information FN_B G _-1 _Dual~action aadressable pull station. Includes key; ocking feature. (Listed for Canadian andoCanadiaappI atipns.)I NBG-12LXSP: Spanish/English labelled version. NBG-1 2LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E. 1CSFM71500028dT FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). BSMI: C1313066760047. U.S. Coast Guard. Lloyd's Register. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I I CINUEINt & MANUFACTURING All specifications are subject to change without notice. I QUALITY SYSTEMS Made inthe U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-67260 • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (,7150-00280199) Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-12-LO, NBG-12L0B, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBG-12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG-12SP, NOT-BG12LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-125 are dual action pull stations. Models NBG-12LR and NBG-1 2LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-1 2WP, NBG-1 2LW, NBG-1 2W, NBG-12LWP, NBG-1 2LAO, NBG-1 2L0, NBG-12LAOB and NBG-12L0B are intended for outdoor use when installed with Models WBB, SB-I/O. or WP-1 0 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. Corrected 10-08-12 bh This listing is based upon technical data submitted by the the test results and/or other data but does not make an independent applicant. CSFM Fire Engineering staff has reviewed verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (June 3O,!) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6935:E • H-202 FSP-851 (A) Series N OT F I E R® Intelligent Plug-In Photoelectric Smoke Detectors with FlashScan® by Honeywell General Notifier FSP-851 (A) Series intelligent plug-in smoke detec- tors with integral communication provide features that sur- pass conventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is con- tinuously monitored and reported to the panel. Point ID capa- bility allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 (A) photoelec- tric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed- temperature thermal sensing on the FSP-851T(A). The FSP- 851 R(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851 (A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 360° viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashS- can systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appear- ance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. FSP-851(A) in B2IOLP(A) Base Specifications Sensitivity: 0.5% to 2.35% per foot obscuration Size: 2.1' (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1" (15.5 cm) diameter. - B501 (A): 4.1" (10.4 cm) diameter. - B200S(A): 6.875" (17.46 cm) diameter. - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. - B224B1(A): 6.2" (15.748 cm) diameter. Shipping Weight: 5.20z. (147g). Operating Temperature range: FSP-851(A), 0°C to 49°C (32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 1000F). Low temperature signal for FSP-851T(A) at 45°F +1- 10°F (7.22°C +1- 5.540C). FSP-851R(A) installed in a DNR(A)/ DNRW, -20°C to 70°C (-4°F to 158°F). ULIULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/ mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (57°C) DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, docu- ment A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 300pA @ 24VDC (one com- munication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 24 VDC ("ON"). DN-6935:E.2/11/2015—Page 1ot 2 Installation FSP-851 (A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors with- out using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junc- tion boxes, see DN-60054. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applica- tions may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: 51115. ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP- 851TA). MEA Listed: 225-02-E. FM Approved. (SFM: 7272-0028:0206). Maryland State Fire Marshal: Permit #2122. BSMI: C1313066760036. CCCF: Certif. #2004081801000017 (FSP-851T) Certif. # 2004081801000016 (FSP-851). U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/ 0 (NFS2-640/NFS-320/NFS-320C, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: "A" suffix indicates ULC Listed model. (FSP-851: Low-profile intelligent photoelectric sensor. Must (be pu nted to one of the ,bases listed b&ow FSP-851A: Same as FSP-851 but with ULC listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. FSP-851R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRA/DNRW. FSP-851RA: Same as FSP-851R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. 821 OLPBP: Bulk pack of B21OLP; package contains 10. B501 (A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224R6(A): Plug-in System Sensor relay base. Screw ter- minals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A © 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC inductive. B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases. ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of Fib; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B21OLP(A) bases only. SMB600: Surface mounting kit M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with FSP-851(A) only; box of 10. WCK-200B: White detector covers for use with FSP-851(A) only; box of 10. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. BYSINEERING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6935:E • 2/11/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FMMA FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 272-0028:0206J Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-751, FAPT-851, FSP-851, FSP-851 R* and FSP-8511 photoelectric type smoke detectors. Models FSP-751T and FSP-851T employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible base and fire alarm control units. Models FSP-751, FSP-751T, FAPT-751, FAPT-851, FSP-851, FSP851R*, FSP-8511 are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air velocities between 0-300 fpm. Model FSH-751 is suitable for open areas with air velocity between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires tii 30, 2018) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6936:6 • H-211 FST-851 (A) Series Intelligent Thermal (Heat) Detectors L(f,'NOTIFIER' with FlashScan® by Honeywell General Notifier FST-851(A) Series intelligent plug-in thermal detectors with integral communication has features that surpass conven- tional detectors. Point ID capability allows each detector's address to be set with rotary, decimal address switches, pro- viding exact detector locations. FST-851 (A) Series thermal detectors use an innovative thermistor sensing circuit to pro- duce 1351F/570C fixed-temperature (FST-851/A) and rate-of- rise thermal detection (FST-851 A/A) in a low-profile package. FST-851 H(A) provides fixed high-temperature detection at 1 90°F/88°C. These thermal detectors provide effective, intelli- gent property protection in a variety of applications. FST- 851(A) Series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by Notifier Engineering that greatly enhances the speed of communication between analog intelligent devices and certain NOTIFIER systems. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Rate-of-rise model (FST-851 A/A), 15°F (8.3°C) per minute. Factory preset fixed temperature at 135°F (570C); high-tem- perature model fixed at 190°F (880C). Addressable by device. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Two-wire SLC connection. Visible LEDs "blink" every time the unit is addressed. 3600-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type identifica- tion. Remote test feature from the panel. Built-in functional test switch activated by external magnet. Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). Low standby current. Backward-compatible. Built-in tamper-resistant feature. Designed for direct-surface or electrical-box mounting. Sealed against back pressure. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelec- tric, ionization and thermal sensors. SEMS screws for wiring of the separate base. Constructed of oft-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. FST-851(A) in B2IOLP(A) Base 94-5V plastic flammability rating. Remote LED output connection to optional RA100Z(A) remote LED annunciator. Optional sounder, relay, and isolator bases. Optional flanced surface mounting kit. Specifications Size: 2.1 (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1° (15.5 cm) diameter. - B501 (A): 4.1" (10.4 cm) diameter. - B200S(A): 6.875" (17.46 cm) diameter. - B200SR(A): 6.875 (17.46 cm) diameter. - B224RB(A): 6.2' (15.748 cm) diameter. - B2246 1(A): 6.2" (15.748 cm) diameter. Shipping weight: 4.8 oz. (137 g). Operating temperature range: FST-851(A) Series, FST- 851 R(A): —20°C to 38°C (-4°F to 100°F); FST-851 H(A): —20°C to 66°C (-4°F to 1500F). Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% - 93% noncondensing. Thermal ratings: fixed-temperature setpoint 135°F (571C), rate-of-rise detection 15°F (8.3°C) per minute, high tempera- ture heat 190°F (880C). ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 300 pA @ 24 VDC (one com- munication every 5 seconds with LED enabled). LED current (max.): 6.5 mA © 24 VDC ("ON"). Applications Use thermal detectors for protection of property. For further information, go to systemsensor.com for manual 156-407-00, Applications Manual for System Smoke Detectors, which pro- vides detailed information on detector spacing, placement, zoning, wiring, and special applications. DN-6936:13. 12107/2011 —Page lot 2 Installation The FST Series plug-in intelligent thermal detectors use a sep- arate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. A spe- cial tool allows maintenance personnel to plug in and remove detectors without using a ladder Mount base (all base types) on an electrical backbox which is at least 1.5* (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document.ln some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S747. ULC Listed: S6978. MEA Listed: 383-02-E. FM Approved. CSFM:727O-QO28:Qi96) BSMI: C1313066760025. CCCF: Certif. #2004081801000018. U.S. Coast Guard: 161.002142/1 (NFS-640); 161.002150/0 (NFS2-640/NFS-320/NFS-320C, excluding 821OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/N FS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: "A" suffix indicates ULC Listed model. cFST Must 66 mounted to onel (of the bases listed be Iow) FST-851A: Same as FST-851 but with ULC Listing. FST-851R: Intelligent thermal detector with rate-of-rise fea- ture. FST-851 RA: Same as FST-851 R but with ULC Listing. FST-851 H: Intelligent high-temperature thermal detector. FST-851 HA: Same as FST-851 H but with ULC Listing. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. B200S(A): Addressable Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Intelligent relay base. Screw terminals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A © 30 VDC induc- tive. B224B1(A): Intelligent isolator base. Isolates SLC from loop shorts. Maximum: 25 devices between isolator bases; see Note 2 under Installation. ACCESSORIES F1I0: Retrofit flange to convert 821OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Fits U.S. single-gang electrical box. Supported by B21OLP(A) and B501 (A) bases only. SMB600: Surface mounting kit, flanged. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. Includes T55-127-01 0. T55-1 27-010: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so 000i This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. BIICINIISINt & MA1UFCRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-69363 • 12/07/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:0196) Page 1 of 1 CATEGORY: 7270-- HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneywell.com DESIGN: Models FST-751, -851, -851R, -851H (fixed temperature) and FST-751R (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models FST-751, -751R, -851, and -851R = 135°F fixed temperature Model FST-851H = 190°F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Models B501, *13210LP (CSFM Listing No. 7300-1653:0109), or B71OLP base (CSFM Listing No. 7300-0028:173) and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *11222016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires [June 30,20183 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division dn-1271:Al • 1-307 3©2ees Rate-Anticipation Heat Detectors by Honeywell OQftThi General The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8" (10.48 cm). Base diameter: 2' (5.08 cm). Electrical Ratings Voltaae Current 6-125VDC 5amps 6-25VDC lamp 125 VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50 x 50 (15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. ödëk302 7 /4 4511302IEM.r -M III 302IEji I271phoI.pg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-1 35/-194; 302-ET-135/-194; 302-135/-194) CSFM: 7270-0021:001 12714141.111 FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELLS 040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW DEVCON HERMETIC SEAL Cut-Away View dn-1271:A1 • 12123/08— Page 1 of 2 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-1 35 135°F All-Weather Vertical Mounting Note 2 below 302-AW-1 94 194°F All-Weather Vertical Mounting 302ET135] 135F'All:WeatheVertical Mounting) Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-135 135°F Explosion Proof Mounting Note 4 below 302-EPM-194 194°F Explosion Proof Mounting AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4" outlet box. NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50'x 50(15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to 'THW' or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. NOTIFIER® is registered trademark of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I o 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING &MUMt1URINC All specifications are subject to change without notice. QU ALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-1 271 Al • 12123/08 dn-1271:Ai • 1-307 302 Series NOTIFIER® Rate-Anticipation Heat Detectors by Honeywell Conventional IInitiating lIDevicesI INN General The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8 (10.48 cm). Base diameter: 2° (5.08 cm). Electrical Ratings 6-125VDC 5amps 6-25VDC lamp 125 VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50' x 50'(15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. I27IphoI.pg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-1 35/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-1 35/-194; 302-ET-135/-194; 302-135094) CSFM: 7270-0021:001 127141a1 III FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELL 0040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW OEVCON HERMETIC SEAL Cut-Away View dn-1271:AI • 12/23/08- Page 1 of 2 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-1 35 135°F All-Weather Vertical Mounting Note 2 below 302-AW-1 94 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-135 135°F Explosion Proof Mounting Note 4 below 302-EPM-1 94 194°F Explosion Proof Mounting AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4° outlet box. NOTE 1: For inferior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50'x 50'(15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to °THV'I° or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2° (1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 112"(1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. dl We cannot cover all specific applications or anticipate all requirements. ENCINIMING & MNUMtTURINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2 - dn-1 271:A1 • 12/23/08 dn-1271:A1 • 1-307 M) )NOTIFIER' by Moneywell Conventional Initiating Devices General 302 Series Rate.Anticioation Heat Detectors The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8 (10.48 cm). Base diameter: 2 (5.08 cm). Electrical Ratings Voltage Current 6-125VDC 5amps 6-25VDC lamp 125 VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50' x 50'(15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. I27Iphol pg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-135/-194; 302-ET-135/-194; 302-135/-194) CSFM: 7270-0021:001 I271dIa1.IiI FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELLS 040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW OEVCON HERMETIC SEAL Cut-Away View dn-1271:A1 '12/23/08—Page 1o12 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-1 35 135°F All-Weather Vertical Mounting Note 2 below 302-AW-194 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-1 35 135°F Explosion Proof Mounting Note 4 below 302-EPM-1 94 194°F Explosion Proof Mounting AP-P I Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4" outlet box. NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50' x 50' (15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to "THIN" or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. NOTIFIER® is registered trademark of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. BVGINEIRING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— dn-1 271 Al • 12/23/08 dn-1271:A1 • 1-307 3O2ees Rate-Anticipation Heat Detectors by Honeywell I General - The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detectors setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8" (10.48 cm). Base diameter: 2" (5.08 cm). Electrical Ratings Voltage Current 6-125VDC 5amps 6-25VDC lamp 125 VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50' x 50'(15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. I271phoI.pg Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-1 35/-194; 302-ET-135/-194; 302-135/-194) CSFM 7270-0021:001 I27IdIa1til FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELL 0040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW DEVCON HERMETIC SEAL Cut-Away View dn-1271 Al • 12/23/08 - Page 1 012 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-1 35 135°F All-Weather Vertical Mounting Note 2 below 302-AW-1 94 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-1 35 135°F Explosion Proof Mounting Note 4 below 302-EPM-1 94 194°F Explosion Proof Mounting AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4" outlet box. NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50'x 50'(15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to "THIN" or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I So ooi We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 - dn-1 271:A1 • 12/23/08 dn-1271:A1 • 1-307 302 Series NOTIFIER® Rate-Anticipation Heat Detectors by Honeywell Conventional I flh1flIfl1DevicesI] General N The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8 (10.48 cm). Base diameter: 2 (5.08 cm). Electrical Ratings Voltage 6-125VDC Current 5amps 6-25VDC lamp 125 VOC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50' x 50'(15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. 127 Ipho1.g Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-1 35/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-1 35/-194; 302-ET-135/-194; 302-135/-194) CSFM: 7270-0021:001 I27Idia1.IiI FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELL S040 ANODIZED ALUMINUM HEAT ANTICIPATION CONTROL SLEEVE SETTING SCREW OEVCON HERMETIC SEAL Cut-Away View dn-1271 Al • 12/23/08- Pagel of 2 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-1 35 135°F All-Weather Vertical Mounting Note 2 below 302-AW-194 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-1 35 135°F Explosion Proof Mounting Note 4 below 302-EPM-1 94 194°F Explosion Proof Mounting AP-P I Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4° outlet box. NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50 x 50(15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to'THIN" or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. NOTIFIER® is registered trademark of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I So 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. B8lNh(fllNG 8 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2 —dn-1271:AI • 12/23/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE LISTING No. ã-oôi:ooi Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Thermotech lnc.,2900 North 1000 West, Ogden, UT 84414 Contact: A. Mark Headley (801) 782-2233 Fax (801) 782-1746 Email: thermotechinc@hotmail.com DESIGN: Models 302, 302H, 302AW, 302E1 and 302EPM heat detectors. Units are open circuit, 1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-ET or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC or VDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-ET and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: Listee's name, model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. Rev. 05-01-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires CJune 30,2O18J Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-60429:C1 DNR(A)IDNRW InnovairFiex NOTI Fl ER® Intelligent Non-Relay Photoelectric 0 Duct Smoke Detector by Honeywell General The Notifier InnovairFIex® DNR(A) intelligent non-relay photo- electric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 to 20.32 m/s), temperatures of -4°F to 158°F (-20°C to 700C), and a humidity range of 0 to 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sensor cover. The Notifier InnovairFIex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- ing and mounting of a relay module. The Notifier InnovairFIex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. Features Photoelectric, integrated low-flow technology. Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/s). Versatile mounting options: square or rectangular configu- ration. Broad ranges for operating temperature (-4°F to 158°F, - 20°C to 70°C) and humidity (0% to 95% non-condensing). Patented sampling tube installs from front or back of the detector with no tools required. Cover tamper signal. Increased wiring space with a newly added 3/4" conduit knockout. Available space within housing to accommodate mounting of a relay module. Easily accessible code wheels on sensor head (sold sepa- rately). Clear cover for convenient visual inspection. Remote testing capability. Requires corn line power only. Accommodates the installation of an addressable relay module, sold separately, (FRM-1 or NC-100R) for applica- tions requiring a Form-C relay. Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depth. Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth. Weight: 1.6 lb (0.73 kg). Operating Temperature Range: -4°F to 158°F (-20°C to 70°C). Storage Temperature Range: •-22°F to 158°F (-30°C to 70°C). Operating Humidity Range: 0% to 95% relative humidity (non-condensing). Air Duct Velocity: 100 to 4,000 ft'min (0.5 to 20.32 m/s). Accessories Notifier provices system flexibility with a variety of accessories, including two remote test stations and different means of visi- ble and audiLle system annunciat on. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. DNR(W)s witi a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORY CURRENT LOADS AT24 VDC Device Standby I Alarm RA100Z I OmA 12 mA Max RTS151/ OmA 2mA Max RTS151 KEY Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listhg may be in process. Con- sult factory fo- latest listing status. UL: S91 1, S3705. ULC: S635. DN-60429:C1 .4119/2012—Page 1 0t2 1sFMr32421653 FM approved. Product Line Information NOTE: '4 suffix indicates ULC listed model. (bNR(A)lllit non-relihotoelectric low flow smok) çdetector housing.. Requi res photoelectric smoke detector (sold) separateiy). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately). FSP-851R(A): Remote test capable addressable low-profile photoelectric smoke detector. FSP-851(A): Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector for FireWarden series panels. NP-100R(A): Remote test capable addressable low-profile photoelectric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A): Metal sampling tube duct width up to 1 ft (0.3m). DST1 .5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3(A): Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m). DST5(A): Metal sampling tube duct widths up to 4 ft to 8 ft (1.2 to 2.4 m). DSTiO(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1: Weatherproof enclosure. ETX: Metal exhaust tube duct, width 1 ft (0.3 rn). M02-04-00: Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z(A): Remote annunciator alarm LED. RTSi 51 (A): Remote test station. RTS1 51 KEY(A): Remote test station with key lock. Important Note DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Notifier® and FlashScan® are a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 000i We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. FNCIN!ERINC A MANUFACTURINS All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-60429V • 4/19/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. L3242-1653:0209) Page 1 of 1 CATEGORY: 3242 -- DUCT SMOKE DETECTOR, PHOTO. (W/ OR W/O BASE) LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models DNR, DNRW, DNRHS and DNRECL* analog photoelectric duct smoke detector housings. The units consist of a duct detector housing, exhaust tubes, and separately listed compatible detector head. Model DNRW is a Type 4(NEMA4) watertight enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 03-23-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6720:E FMM-1 (A), FMM.1 01(A),riqk FZM-1(A) & FDM-1(A) NOTIFIER® Monitor Modules with FlashScan® by Honeywell Intelligent/AddressableDevices General Four different monitor modules are available for Notifiers intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM.1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3' (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM.1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM-1 (A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 - 99 on CLIP loops. LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- FMM-1(A) (Type H) open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125(5.398cm) deep box. DN-6720:E • 07/30/2015 - Page 1 of 4 FMM.101 (A) Mini Monitor Module Temperature range: 32°F to 120°F (0°C to 49°C). Built-in type identification automatically identifies this Humidity range: 10% to 93% noncondensing. if,,, ,v,,,, 1 I,, +k Jvnd 00 0 nd! IItiJr I IUUUlC L¼1 LI IC H.". Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 - 99 on CLIP loops. 0 1415 0 1 ADDRESS 11 4 i LOOP 4 109 8 7 6 TENS ONES o 1u c o w • —J 0 o 00 The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. FMM- 101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop, It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.6511(1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM.1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on FlashScan loops, 01 - 99 on CLIP loops. LED flashes during normal operation; this is a program- mable option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM.1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Page 2 of 4— DN-6720:E .07/30/2015 Humidity range: 10% to 93% noncondensing. Agency Listings and Approvals Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x In some cases, certain modules may not be listed by certain 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x approval agencies, or listing may be in process. Consult fac- 2.125" (5.398 cm) deep box. tory for latest listing status. FDM-1 (A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY. Style 0 (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1 (A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1 (A) is set to address '26", then it will automatically assign itself to addresses "26" and '27". NOTE: "Ones" addresses on the FOM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. UL: S635. ULC:S635. FM Approved. CSFMI7300-0028:0219 7165-0028:0224, 7165-0028:0243. MEA: 457-99-E. U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NFS2-3030). Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). Fire Dept. of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. MM1101(A) Monitor module miniature FZM-1(A): Monitor module, two-wire detectors. FDM.1(A): Monitor module, dual, two independent Class B circuits. SM113500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4(10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. DN-6720:E 07/30/2015 - Page 3 of 4 FlashScanID and NOTIFIERS are registered trademarks and FireWatchTM is a trademark of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. dl 1 We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MNUFAt1URINC QUALITY SYSTEMS All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6720:E• 07/30/2015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:021 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM..1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (June 30, 2018) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6724:B3 FCM-1(A) & FRM.1(A) NOTIFIER® Series 0 Control and Relay Modules by Honeywell General FCM-1(A) Control Module: The FCM-1(A) Addressable Con- trol Module provides Notifier intelligent fire alarm control pan- els a circuit for Notification Appliances (horns, strobes, speakers, etc.). Addressability allows the FCM-1(A) to be acti- vated, either manually or through panel programming, on a select (zone or area of coverage) basis. FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay Module provides the system with a dry-contact output for acti- vating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER Engineering that greatly enhances the speed of communication between analog intelli- gent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. The FCM-1 (A) module requires power (for horns, strobes, etc.), or audio (for speakers). Integral LED blinks" green each time a communication is received from the control panel and turns on in steady red when activated. LED blink may be deselected globally (affects all devices). High noise immunity (EMF/RFI). The FCM-1 (A) may be used to switch 24-volt NAG power, audio (up to 70.7 Vrms). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address 01— 159 for FlashScan loops, 01 —99 for CLIP mode loops. Speaker, and audible/visual applications may be wired for Glass B or A (Style Y or Z). Applications The FCM-1(A) is used to switch 24 VDG audible/visual power, high-level audio (speakers). The FRM-1(A) may be pro- grammed to operate dry contacts for applications such as door holders or Air Handling Unit shutdown, and to reset four-wire smoke detector power. NOTE: Refer to the SLC Manual (PN 51253) for details regarding releasing applications with the FCM-1(A). Refer to the FCM-1-REL datasheet (DN-60390) for new FlashScanO releasing applications. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address (01-159). FCM-1 (A) The FGM-1 (A) is configured for a single Glass B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The FRM-1(A) provides two Form-C dry contacts that switch together. Operation Each FCM-1 (A) or FRM-1 (A) uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notifica- tion Appliance Circuit (NAG). The LED blinks with each poll received. On command, it activates its internal relay. The FCM-1 (A) supervises Glass B (Style Y) or Glass A (Style Z) notification or control circuits. Upon code command from the panel, the FCM-1(A) will dis- connect the supervision and connect the external power sup- ply in the proper polarity across the load device. The disconnection of the supervision provides a positive indication to the panel that the control relay actually turned ON. The external power supply is always relay isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a module and a sen- sor address. Specifications for FCM-1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 350 pA direct poll, 375 pA group poll with LED flashing, 485 pA Max. (LED flashing, NAG shorted.) DN-6724:B3 • 2/17/2011 - Page 1 of 2 Maximum NAC Line Loss: 4 VDC. External supply voltage (between Terminals T10 and Til): Maximum (NAC): Regulated 24 VDC; Maximum (Speakers): 70.7 V RMS, 50W. Drain on external supply: 1.7 mA maximum using 24 VDC supply; 2.2 mA Maximum using 80 VRMS supply. Max NAC Current Ratings: For class B wiring system, the current rating is 3A; For class A wiring system, the current rat- ing is 2A. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (114.3 mm) high x 4" (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4' (101.6 mm) square x 2.125° (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Specifications for FRM.1(A) Normal operating voltage: 15 to 32 VDC. Maximum current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll; 255 pA group poll. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (114.3 mm) high x 4° (101.6 mm) wide x 1.25° (31.75 mm) deep. Mounts to a 4° (101.6 mm) square x 2.125° (53.975 mm) deep box. Accessories: SMB500 Electrical Box; CB500 Barrier Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S3705 (A version only) FM Approved MEA: 14-00-E FDNY: COA #6067, #6065 Contact Ratings for FRM.1 (A) Current Maximum Load Application Rating Voltage Description 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5A 30 VDC Inductive (L/R=5ms) Coded 1A 30 VDC Inductive Coded (L/R=2ms) .3A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded NOTE: Maximum (Speakers): 70.7 V RMS, 50 W Product Line Information NOTE: "A" suffix indicates ULC Listed mode!. FCM-1 (A): Intelligent Addressable Control Module. (FRM1(A)lntelligent Addressable Relay Module.) A2143-20: Capacitor, required for Class A (Style Z) operation of speakers. SMB500: Optional Surface-Mount Backbox. C13500: Control Module Barrier - required by UL for separat- ing power-limited and non-power limited wiring in the same junction box as FCM-1 (A). NOTE: For installation instructions, see the following documents: FCM-1(A) Installation document /56-1169. FRM-1(A) Installation document 156-3502. Notifier SLC Wiring Manual, document 51253. S NotIfIer® and FlashScan® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO9001 We This document is not intended to be used for installation purposes. try to keep our product information up-to-date and accurate. :b dl I .1 We cannot cover all specifIC applications or anticipate all requirements. IM BtGINFRINt MMIUCRIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2- DN-6724:133 • 2/17/2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-0028:0219) Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *F0RM1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS27640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. b *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires (June 3O,!) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division