Loading...
HomeMy WebLinkAbout7570 GIBRALTAR ST; ; FPR2017-0219; PermitPERMIT REPORT (7city of Carlsbad Print Date: 10/12/2021 Job Address: 7570 GIBRALTAR ST, CARLSBAD, CA 92009-7487 Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Alarm Parcel #: Track #: Valuation: $0.00 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Project Title: Description: LA COSTA VILLAS -SPRINKLER MONITORING SYSTEM SYSTEM INCLUDES NORTH AND SOUTH BUILDING Permit No: FPR2017-0219 Status: Closed - Finated Applied: 06/07/2017 Issued: 06/20/2017 Finaled Close Out: 08/04/2021 Inspector: Final Inspection: Applicant: FPContractor: HCI SYSTEMS INC HCI SYSTEMS INC JEFF RODGERS 4585 MURPHY CANYON RD 4585 MURPHY CANYON RD SAN DIEGO, CA 92123-4318 SAN DIEGO, CA 92123-4318 (909) 628-7773 (858) 560-7000 FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov HC1 Systems Inc. FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Sprinkler Monitoring System Complete Material Submittal Prepared for: LA COSTA VILLAS 7570 GIBRALTAR ST., CARLSBAD, CA 92009 FPR20I7-0219 7570 Gibraltar ST - Ontario • San Diego • Irvine • Northern California Corporate Office: 1354 South Parkside Place, Ontario, CA 91761 Phone: (877) 331-2084 FAX: (909) 628-7774 24-Hour Service: (909) 628-8886 Website: www.hcisystems.net is LA COSTA VILLAS 7570 GIBRALTAR ST., CARLSBAD, CA 92009 Manufacturer Device Model # Description C.S.F.M. # KIDDE VS1-RD Fire Alarm Control Panel - Red, Dialer 7615:1615:0244 DSC 3G4010-CF Cellular Communicator 7300-1273:0161 KIDDE GSA-PS Intelligent Photoelectric Smoke Detector 7272-1483:0122 KIDDE GSA-M278 Manual Pull Station 7272-1483:0139 KIDDE GSA-CT2 Dual Input Monitor Module 7300-1483:0115 DSC RM-2 Relay Module 7300-1273:0127 SPACE AGE ACE-11 Fire Alarm Document Cabinet 7300-0553:0110 ~1 FDNY COA 6229 IS 7165-1657: 0244 I000I Features Auto-programming speeds installation time Supports V-Series intelligent modules and detectors Form C contacts for alarm and trouble, Form A for supervisory Electronic addressing with automatic device mapping Optional Ethernet port for diagnostics, programming and a variety of system reports Two programmable switches with LEDs and custom labeling Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization Supports GSA-REL releasing module for fire suppression Class B or Class A wiring Ground fault detection by module Supports up to eight serial annunciators, (LCD, LED-only, and graphic interface) Can use existing wiring for most retrofit applications Upload/download remotely or locally Two-level maintenance alert reporting Pre-alarm and alarm verification by point Adjustable detector sensitivity 4 x 20 character backlit LCD display Optional earthquake hardening: seismic Importance Factor 1.5 Standalone operation Transmission test frequency by hour i, Small Building Fire Alarm Solutions S Technologi Technology that saves lives Intelligent Fire Alarm Systems =VS1 VS4 Overview Kidde brand intelligent life safety systems offer the power of high- end intelligent processing in configurations that deliver uncompli- cated solutions for small to mid-sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily-configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The VS1 provides one Class B intelligent device loop that sup- ports up to 64 device addresses, and two Class B Notification Ap- pliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The VS4 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. VS4 panels include four NACs that may be wired for either Class A or Class B operation. The RZ116-2 module adds even more capacity to VS installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them ideal retrofit solu- tions that can accommodate new intelligent detectors, as well as existing conventional devices. VS Series supports a wide range of high-end features, including: Intelligent modules, detectors, and bases GSA-REL Releasing Modules R-Series remote annunciators Integrated Carbon Monoxide gas sensing with V-PCOS de- tectors including distinct audible signaling Page lol8 DATA SHEET V850050135 NeI tc b d tO in t .iL.t,or prpu.e Issue 1 Application Kidde VS Series life safety systems are powerful intelligent solutions for small to mid-sized buildings. Advanced intelligent technology delivers the benefits of flexible system installation, while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Electronic addressing eliminates the tedium of setting dipswitches, and automatic device mapping ensures that each device resides on the system at its correct location. Meanwhile, innovative pro- gramming allows the designer to customize the system to pre- cisely suit the needs of the building owner. Reliability you can count on The inherent fault-tolerant characteristics of Analog/Address- able Technology boosts the reliability of Kidde fire alarm systems. When combined with VS Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small to mid-sized applications. All Kidde systems are built to exacting reliability benchmarks and meet international standards for quality, in addition to agency listings for dependability. Clear-cut remote annunciation Remote annunciation is a strong suit of the VS Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as com- mon control capabilities. VS control panels also supports graphic annunciation with optional graphic annunciator interface modules. Each interface provides common control and 32 LEDs. Programming and remote diagnostics Kidde VS Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, VS Series systems interface to a PC running com- patible VS-CU software. This option offers full system configura- tion in the familiar Windowse operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of VS Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethemete network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to down- load to the panel from the VS-CU, or upload and view system reports using the VS-CU. Available system reports include: Flexibility built right in Two fully-programmable front panel switch/LED combinations pro- vide an added measure of flexibility. Their slide-in labels take the mystery out of custom applications, and present a clean finished appearance. Perfect for retrofits Kidde VS Series control panels are particularly well-suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to VS technology without the expense or disruption of rewiring the entire building. VS control panels also support the ingenious RZl16-2 zone module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intel- ligent detection alongside existing conventional circuits, making it an superior solution in the retrofit market. Signals with a difference VS Series NACs are configurable to fully support the advanced signaling technology of Kidde Genesis and Enhanced Integrity no- tification appliances. These devices offer precision synchronization of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. A complete line of accessories VS Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions (2) (3) (4) D7 T • 0 0 0 0 04 Surface Mounting Holes (3) Backbox with Door Attached Semi-flush mounting Holes (4) Backbox with door and trim kit attached. Panel dimensions, In (cm) Modal T oil 02 3.85 03 9.0 ° T 05 15.75 06 10.25 riJ 4.9 08 1 30.1 1 2.7 VS4 1 28.0 (71.1) (9.8) (22.8) (55.8) (40.0) (26.0) 10.25 (12.4) 4.9 (76.4) (6.8) 1 23.6 1 2.7 1 T 21.5 7.5 T 15.5 14.25 (54.6) (9.8) (19.0) (39.4) (36.2) (26.01 (12.4) L'I L nll~_~ Correlation groups Device details Device maintenance History Internal status System configuration System status Walk test Dialer CO runtime * Add 1-1/2 in. (3.81 cm) toOl and D5 dimensions for trim kit. The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. Page 2 of 8 V85005-0135 Issue 1 Panel Layout 6 7 8 9 10 11 12 13 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (Ji) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries System Layout VS4 Any combination of two single- or dual device loop modules Hj- ---_ -f —E---c:j--c —c-- Standard Loop: 250 points (one expansion slot) V-SLC2-2 Expander, Loop 1 of 2: 250 points Up !? 125 '? °f° (one expansion slot) oil V-SLC2-1 Expander Loop: 250 points (one expansion slot) V-SLC2.2 Expander, Loop 2 of 2: 250 points ,Up to 20,000 feet of wiring per loop iClassBoiooplionalclassANACs L *FouriasioopIionaliANACs ] Optional 10 or6.5A Booster Ethernet (SA-ETh) fJ•__i ___..J DACT/Dialer (SA-DACT) Up to eight remote annunciators RS-232 (SA-232) . Sixteen Conventional lDCs, Relays: Two Form C, one Form A two additional NACs with RZ116-2 module Each VS4 panel has room for up to two device loop controller modules in any combination of single or dual 250-device loops. VS4 comes with one loop that supports up to 125 detectors and 125 modules. S C C [f(... Loop supports up to 64 intelligent devices of any type. Up to 20,000 feet of wiring. 11 Two Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster Power Supply Up to eight remote annunciators Ethernet (SA-ETH) DACT/Dialer (SA-DACT) RS-232 (SA-232) Relays: Two Form C, one Form A Each VS1 panel ships with one device loop controller that sup- ports 64 devices of any type. This panel's device capacity cannot be expanded. Page 3ot8 DATA SHEET V850050135 No t. t. 1 1j1ur' .. Issue I ,I. _ NE ______ (+) IN ' [4CH2 (+) IN (-) IN I CH2 (-) IN Class awiring OassA wiring OLR QLR Wiring & Configuration Device loop The system provides one device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit VS4 VS11, specifications __ Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Communication Maximum 20 V peak-to-peak line voltage Circuit current 0.5 A max Circuit 660 total, 0.5 pF, max impedance Isolators 64 maximum Signal Supported on a system-wide basis (all device loops) Synchronization when using an addressable notification appliance circuit (NAC) module and Genesis or Enhanced Integrity notification appliances. Class 8 wiring Class A wiring LOOP LOOP Wei) LW ~devlw Loopre,d desire desire oeca' taiire Notification appliance circuits (TB2) VS4 control panels come equipped with four notification appliance circuits. VS1 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications VS4 VS4 -- VS1 Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with _SA-CLAmodule Voltage 24 VFWR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 50 Hz. Impedance 26 C) total, 0.35 lJF max EOLR 15K0,½W Synchronization Supported system-wide Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary equipment such as remote annunciators and two wire smoke detectors. Aux 2 can be software selected to operate continuously. The circuit is supervised for shorts and grounds. Circuit specifications Circuit voltage 21.9 to 28.3 V range Resettable circuit 24 VDC nominal at 500 mA (Aux power 2) Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering two-wire smoke detectors. Note: Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that amount. Trouble Supervisory Alarm, trouble, and supervisory relay (TB3) (3% am The trouble relay is normally-open, held closed, 1 and opens on any trouble event or when the (4) Smoke/Aux panel is de-energized. The supervisory relay is normally-open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Alarm I Trouble Supervisory Type Form C Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power-limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style 't') or Class A (Style Z) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Class B Class A Channel 1 Channel 2 Channel 1 Channel 2 +—+— fl Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown In active state. Page 4ol8 DATA SHEET V850050135 Not to be used for Installation purposou. Issue 1 hiulemet care I-L-1 Option Cards Kidde VS Series panels are supported by a complete line of mod- ules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet pro- vides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The V-SLC2-1 is a single loop controller card that can be used with the VS1 as a replacement for the standard 64-point loop, or with the VS4 as a 250-point expansion module. The V-SLC2-2 is a 500-point dual loop controller card for the VS4 that provides two IDC circuits, each with 125 detector addresses and 125 module addresses. [specifications - V-SLC2-1 V-SLC2-2 Device Addresses VS4: one loop, 250 device addresses VS1 64 addresses VS4: two loops, 500 device addresses Wiring Class B or Class A Operating Voltage 24 VDC Operating Current (fully loaded loop) Standby: 55 mA Alarm: 80 mA Standby: 45 mA I Alarm: 70 mA Note: These ratings do not include the use of two-wire smoke modules. Communication Line Max. 20.6 V peak-to-peak Voltage Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm2) Circuit Current 0.5 A max. Max total loop 660 resistance Max total loop 0.5 IJF capacitance Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault 0 to 5 kO Impedance Operating 32 to 120°F (0 to 49°C) Environment 0 to 93% noncondensing at 90°F (32°C) SA-ETH Ethernet Interface Card SA-ETH wiring To network The SA-ETH card provides a connection standard 10/100 Base I Ether- net network connection for Network cable connecting to an intranet, a local network, or the Internet. The card can be used to download I configuration programming from I the VS-CU to the panel. The Ethernet card is installed on the plastic assembly and con- nects to the main circuit board via a ribbon cable. ecdications . - - - - .- - Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) RZ116-2 Remote Zone Interface Module The RZl16-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. The RZI16-2 requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZl16-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-seg- ment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZ116-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm current: 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA/ circuit Standby current for 3.9 k EOL (Canada) 5.7 mA/ circuit Alarm current at nominal voltage 31.1 mA/ circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kO (U.S.); 3.9 kO Canada Zone voltage 22.78 V for 4.7 kO (U.S.) 22.08 V for 3.9 kO (Canada) Alarm current 31.1 mA/ channel at nominal voltage Alarm impedance range <680 0 Trouble impedance range > 5.55 kO Supervised output circuits EOL resistor 15 kO Quantity 2 Short circuit detection <2.6 kfl Open circuit detection > 61.9 kO Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC(A), VS4, APS Page 5ol8 DATA SHEET V85005-0135 Not to be used for installation purposes. Issue 1 SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the VS-CU. all tejack The dialer phone lines connect to connectors on the dialer's main circuit board. Phone line 1 connects to connector J4 and phone line 2 connects to connector Ji. The SA-DACT queues mes- sages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activations are transmitted before restora- tions. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. A-DACTspecifcaons Phone line type One or two loop-start lines on a public, switched network Phone line connector RJ-31/38X (C31/38)Q Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBII CP220 Contact ID Osborne-Hoffman OH 2000 Contact ID Bosch D6600 Contact ID Silent Knight 9800 Contact ID Sur-Gard SG-MLR1, MLR2 Contact ID SA-232 RS-232 interface SA-232 wiring The SA-232 card provides an RS-232 in- terf ace with VS panels. It can be used for GND (black wire) TXD (white wire) F connecting a printer to the control panel FF RxD (red wire) to pnnt system events. The card also ______ to download a configuration program can be used for connecting a computer F from the VS-CU to the control panel. _____________ The RS-232 card is installed on the plas- tic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard EIA-232 Terminal rating 12 tol8 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) SA-CLA Class A Module (VSI only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with VS1 control panels only. VS4 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. sA-5LA specifications Operating voltage 24 VFWR Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 to18 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) D16L-VS LED Display Expander (VS4 only) The D1 6L-VS LED Display Expanders provide LED annuncia- tion for up to 16 zones. It provides two LEDs for each zone. Two D16L-VS LED display expanders can be installed in each V54 panel. (3) (4) T (1) I _______________ I I _______________ I _____________ ______ __________ LED 2 LED Expander 1 LED Expander 2 Alarm/non-alarm and trouble zone LEDs Page 6018 DATA SHEET V85005-0135 Not to be uod for rnttcIIatiqn purpo.. Issue 1 Specifications ____________ r ______ VS1 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (125 • modules) detectors and 125 modules max.). Addresses 1 to 125 are Maximum T-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B (Style Y), Class A (Style Z) optional 4 Class B (Style or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz ' 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC circuit Aux power 2: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) Output: 28.3 to 21.9 VDC, special application Note: For a list of compatible devices, see the VS1 and VS4 Series Compatibility List (P/N 3102354-EN) Loop circuit Maximum loop resistance: 66 C) Maximum loop capacitance: 0.5 pF Communication line voltage: Maximum 20.6 V peak-to-peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA Alarm: 125 mA/1 15 mA (nót including two-wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the VS1 control panel cabinet and two 18 Ah batteries will fit in the VS4 control panel cabinet. If larger batteries are required, use a battery cabinet. SA-DACT dialer Phone line type: One or two loop-start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38)) Communication formats: Contact ID (SIA DC-05) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance 0 to 5 kfl Alarm contact Form C N.O. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.O. 24 VDC at 1 A (resistive load) • Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) Page lols DATA SHEET V850050135 Not to be used for installation purposes, Issue 1 Ordering Information Fe,.:5'Kidde - VS4 Fire Alarm Systems VS4-G Four loop system with one 250-point loop installed. 110v, gray door. Technology that saves lives VS4-G-2 Four loop system with one 250-point loop installed. 230v, gray door. VS4-G-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. Contact us VS4-G-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. VS4-GC Four loop system, one 250-point loop installed. llov, gray door, LED strips, Canada. Email: VS4-GD Four loop system, one 250-point loop installed. llOv, gray door, with dialer. Web- Kidde.com/EngineeredSgtems VS4-GF Four loop system, one 250-point loop. 110v, grayoor, LED strips, French Canada. VS4-G-PG Four loop system with one 250-point loop installed. llOv, gray door, Portuguese. Kidde is a UTC brand. VS4-G-SP Four loop system with one 250-point loop installed. 1 10v, gray door, Spanish. 1016 Corporate Park Drive VS4-R Four loop system with one 250-point loop installed. 110v, red door. Mebane, NC 27302 VS4-R-2 Four loop system with one 250-point loop installed. 230v, red door. VS4-RD Four loop system, one 250-point loop installed. 110v, red door, with dialer. © 2016 United Technologies Corporation. SA-1R1M2 VS4 Flush mount trim, black. All rights reserved. VS1 Fire Alarm Systems VS1-G One loop system with one 64-point loop installed. ilOv, gray door. VS1-G-2 One loop system with one 64-point loop installed. 230v, gray door. VS1-G-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. VS1-G-2-SP One loop system with one 64-point loop installed. 230v, gray door, Spanish. VS1-GD One loop system, one 64-point loop installed. llOv, gray door, with dialer. VS1-GL One loop system, one 64-point loop installed. 110v, gray door, English Canada. VS1-GL-F One loop system, one 64-point loop installed. 110v, gray door, French Canada. VS1 -G-PG One loop system with one 64-point loop installed. 110v, gray door, Portuguese. VS1 -G-SP One loop system with one 64-point loop installed. 110v, gray door, Spanish. VS1-R One loop system with one 64-point loop installed. 110v, red door. VS1 -R-2 One loop system with one 64-point loop installed. 230v, red door. VS1 -RD One loop system, one 64-point loop installed. llOv, red door, with dialer. SA-TRlM1 VS1 Flush mount trim, black Option Cards V-SLC2-1 Expansion module, one 250-device loop. For VS4 only. V-SLC2-2 Expansion module, two 250-device loops, 500 devices total. For VS4 only. RZ116-2 Remote Zone Interface Module. 16 Class B lOCs, 2 Class B Output. Bracket included. SA-DACT Dual Line Dialer/Modem, supports Contact ID, mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers & computers, mounts in cabinet. SA-ETH Ethernet Port, Slave, mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. VS1 systems only. D1 6L-VS LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display. For VS4 only. D8RY-VS Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For VS4 only. tTcciisioriiiis - - CTh City Tie Module. 2-gang. Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8" x 14" x 3.5" - red. BC-1 Battery Cabinet. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. BC-1R Battery Cabinet - Red. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. GSA-REL Releasing Module BC-i EQ Seismic hardening Kit for VS Series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools - -- * VS-Cu VS Series configuration and diagnostics utility. 260097 R5232 cable, 4 conductor, DB9 PC interface DATA SHEET V850050135 . Page 8of8 Not to be used for installation purpoe. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7165-1657:024i Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, Inc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Single and multi-loop analog addressable fire alarm control unit. Local, local with shunt, auxiliary, remote station, central station, releasing device. Power limited, non-coded, coded, shunt, reverse polarity, DACT, manual, automatic waterfiow and sprinkler supervisory service. Models "EST" iO1000G, iO1000G-2, iO1000GD, i01000R, IO1000R-2, i0I000RD, i064G, i064-GD, i064-R, i064-RD, i064G-2, iO64R-2; i0500G, i0500GD, i0500R, i0500RD, i0500G-2, iO500R-2. Models "Vigilant/Kidde" VSI-G, VSI-GD, VS1-R,(VSI-RD) VSI-G-2, VS1-R-2; VS2-G, VS2-GD, VS2-R, VS2-RD, VS2-G-2, VS2-R-2, vs4-G, vs4-G-2, vs4-GD, vs4-R, vs4_r-2, vs4-RD,. Models "FireworX/Kidde" FX-64G, FX-64GD, FX-64R, FX-64R0, FX64G-2, FX-64R-2, FX-254G, FX-254G0, FX-254R, FX-254RD, FX254G-2, FX-254R-2, FX-1000, FX1000D. Models "Edwards Signaling' E-FSA64G, E-FSA64GD, E-FSA64R, E-FSA64RD, E-FSA250G, E-FSA250GD, E-FSA250R, E-FSA25ORD . System Components: SA-DACT; Dialer SA-CLA; Class A Adapter SA-ETH; Ethernet Adapter SA-232; R5232 Module D16L-iO, -VS, -Fa, D8RY-iO-1, D8RY-iO-2, D8RY-VS, 16 Zone Front Panel LED XAL250, V-SLC, XALI27; SLC Loop Driver io-SDCI, V-SLC2-1, FX-SLC1 Single SLC Card, 250pt io-SDC2, V-SLC2-2, FX-SLC2 Dual SLC Card, *500pt *pll..S: System Printer *pllp: System Printer Parallel Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120/230 VAC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. *102416 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 2017D Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1657:0244 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. *These control units meet the requirement of UL 864, 9th Edition Standard. *102416 dc This listing is based upon technical dats submittec by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but, does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installatior. criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Divisior __IE~;Wcil From Tyco Security Products SA egaI d1$JjFirke AJ iar Features That Make a Difference: Uses HSPA (3G) network for high-speed, reliable and low- cost communications to an IP receiver Automatically switches to 2G (EDGEJGPRS) if 3G service is not available •• Compatible with control panels that communicate using Contact ID or SIA (300 baud) formats • Full event reporting 4 on-board inputs with NC, NO or SEOL supervision 4 on-board outputs (open collector) Activation and initialization via automated telephone activation system (VRU), web-user or mobile interlace provided by C24 Communications View communicator status directly from your mobile phone to support on-site or remote troubleshooting Compatible with Sur-Gard® System l-IP/ll/lll/IV/5 monitoring station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery .• UL 864 listed • CSFM listed The 3G401 OCF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System l-IP/ll/lll/lV/5). The 3G401 OCF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SIA (300 baud) format. The 3G401 OCF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 and 2013 Editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or 1 hour (NFPA72 2013) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The 3G401 OCF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the 3G401 OCF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. In instances where the control panel does not support Contact ID or SIA (300 baud), the 3G401 OCF has inputs pre-set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the lP linecard of the monitoring station receiver (SurGard® System l-IP/11/IIIIIV/5). 4,. 3G technology from DSC! IS1 dti9L5!i•oi. L. - SGG®I -888ff88-7ft€i8 m __T 1%, n Iffl; ~fmwm M 4 ' I I From Tyco Security Products. Activating & Initializing the Unit Activating and initializing the 3G401 OCF can be done using the automated telephone activation system (VRU), mobile interface or web-user interface provided by 024 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance C24 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost allocated to maintenance. 6 C UL Listing The 3G401 OCF is UL listed under File S4019, Usting guide UO)O(, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the 3G401 OCF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013 guidelines the 3G401 OCF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the 3G401 OCF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The 3G4011 OCF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: 3G401 OCF-USA .......... Universal Wireless Commercial Fire Alarm Communicator (U.S. Model/SIM Card Included) Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the 3G401 OCF requires use of the 4MB (NFPA72 2010) or 500kB (NFPA72 2013) rate plans to support the supervision requirements. Specifications Dimensions ................................................ 11-1/2" x 10 x3 (290 mm x 254 mm x 75 mm) Input Voltage.............................................................120 VAC Current Draw ..............................................200 mA (standby) 400 mA (transmitting) Operating Environment ................32° to 120° F (00 to 49° C) Weight...........................................................12.8 lbs (5.8 kg) Optional Acessories Model Description GS-1 5ANT 15 ft extension antenna (internal use) GS-25ANT 25 ft extension antenna (internal/external use) GS-50ANT 50 ft extension antenna (internal/external use) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7300-1273:011 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Security Controls95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: Model3G4010CFJRF Communicator (GSM-GPRS/3G) signaling device. It is intended for use as a standalone communication technology (standalone unit). It may also be used as a backup communication technology in conjunction with a DACT. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 V, 50/60 Hz, 0.3 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as communicator signaling device for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. 06-03-15 gt 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 2017) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Intelligent Initiating r E L E C T R 0 N I I8jTël10Iogi @iifl D R E S SJNG Technology that saves lives Intelligent Photoelectric Smoke Detector GSA-PS 7272-1483: 012210125 n(2 Overview The Signature Series Model GSA-PS Intelligent Phctoelectric Smoke Detector gathers analog information from its smoke sens- ing element and converts it into digital signals. The detector's on-board microprocessor measures and analyzes these signals. It compares the information to historical readings and time patterns to make an alarm decision. Digital filters remove signal patterns that are not typical of fires. Unwanted alarms are virtually elimi- nated. The microprocessor in each detector provides four a.iditional ben- efits; - Self-diagnostics and History Log, Automatic Device Map- ping, and Fast, Stable Communication. Standard Features Integral microprocessor Non-volatile memory Automatic mapping device Electronic addressing Environmental compensation Intelligent detector Wide 0.67% to 3.77%/ft. sensitivity range Twenty pre-alarm sensitivity values, set in 5% increments Self-diagnostics and History Log - Each Signature Series • Identification of dirty or defective detectors detector constantly runs self-checks to provide important mainte- • Automatic day/night sensitivity adjustment nance information. The results of the self-check are automatically updated and permanently stored in the detector's rn-volatile • Twin RED/GREEN status LEDs memory • Standard, relay, fault isolator, and audible mounting bases Automatic Device Mapping - The loop controller learns where • Designed and manufactured to ISO 9001 standards each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning etc.) in a different location from where it was originally. Fast Stable Communication - On-board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Page lot 4 K85001-0269 Issue 1 Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square electrical boxes 1-1/2 inches (38 mm) deep. They mount to Euro- ean BESA and 1-gang boxes with 60.3 mm fixing centers. I I I 0.8' (20 mm) / 2.0'(51 mm) 4.4(li2mm) Tamper-Resist Lever Arm ' - Break off to disable - (Located on Bose) .. - Access Slot for / Tamper-Resist Mechanism Testing & Maintenance Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitiv- ity measurement can also be transmitted to the loop controller. A sensitivity report can be printed to satisfy NFPA sensitivity meas- urements which must be conducted at the end of the first year 0T -ndevery two years thereafter. he user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper detec- tor operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Compatibility The GSA-PS detectors are compatible only with the Signature Loop Controller. Warnings & Cautions This detector will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your fire protection specialist. This detector will NOT sense fires that start in areas where smoke cannot reach the detector. Smoke from fires in walls, roofs, or on the opposite side of closed doors may not reach the detector to alarm it. [i Accessories All detector mounting bases have wiring terminals that are acces- sible from the "room-side" after mounting the base to the electri- cal box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The GSA-SB4, GSA-RB4, and GSA-lB4 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the GSA-T54 Trim Skirt which is used to cover the "mounting ears" on the base. The GSA-AB4G mounts to a 4" sqare box only. GSA-AB4G GSA-SB GSA-lB GSA-RIB GSA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Standard Base GSA-SB, GSA-SB4 - This is the basic mounting base for Kidde Signature Series detectors. The GSA-LED Remote LED is supported by the Standard Base. Relay Base GSA-RB, GSA-RB4 - This base includes a relay. Normally open or closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The GSA-RB can be operated as a control relay if programmed to do so at the control panel (MlR3 V2 only). The relay base does not support the GSA-LED Remote LED. Audible Base GSA-AB4G - This base is designed for use where localized or group alarm signaling is required. When the detector senses an alarm condition, the audible base emits a local alarm signal. The optional GSA-CAR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. Relay and Audible Bases operate as follows: - at system power-up or reset, the relay is de-energized - when a detector is installed in the base with the power on, the relay energizes for four seconds, then de-energizes - when a detector is removed from a base with the power on, the relay is de-energized - when the detector enters the alarm state, the relay is energized. Isolator Base GSA-lB, GSA-1B4 - This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the GSA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 msec - at 10 msec intervals, beginning on one side of the Class A circuit nearest the loop controller, the isolators close to provide the next isolator down the line with power - when the isolator next to the short closes, reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Remote LED GSA-LED - The remote LED connects to the GSA- SIB or GSA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. GSA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Page 2014 .' K85001 -0269 Issue I - Normally- Normally- Remote LED Not Used DATA IN/OUT (+) Not Used DATA IN (-) Remote LED (-) Remote LED (+) Not Used DATA OUT (-) OAT OUT (+) To Next Device tJP.IP. 1IN From Signature Controller or Previous Device 1 Normally Open 2 DATA IN/OUT (+) 3 Common 4 DATA IN(-) 5 Not Used 6 Normally-Closed 7 DATA OUT (-) CONTACT RATING 1.0 Amp @30 VDC OUT (-) (Pilot Du) Max resistance — per wire must not exceed 10 Ohms I - li 11 ' I DATA OUT I-) DATA IN (+1 DATA OUT 1+1 From Signature Controller To Next Device or Previous Device Term Description 1 Not Used 2 DATA IN/OUT (+) 3 DATA IN(-) 4 Not Used 5 Not Used 6 DATA OUT 7 Not Used OUT(-) Application Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow, smoldering fires. The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors. The table indicates that no single sensing element is suited for all test fires. Kidde recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. GSA-HRS and GSA-HFS Test Fire GSA-PS Photo Rate-of-Rise! Fixed Temp. GSA-PHS Photo Heat 3D GSA-IPHS Ion/Photo/Heat 40 Open Wood unsuitable optimum very suitable optimum Wood Pyrolysis optimum unsuitable optimum optimum Smouldering Cotton optimum unsuitable optimum optimum Poly Urethane Foam very suitable suitable very suitable optimum n-Heptane very suitable very suitable optimum optimum Liquid Fire without Smoke unsuitable optimum very suitable very suitable Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1 .5mm2), and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Standard Detector Base, GSA-SB, GSA-SB4 Relay Detector Base, GSA-RB, GSA-RB4 Isolator Detector Base, GSA-IB, GSA-1B4 Audible Detector Base, GSA-AB4G L)AIAOUI (+) To Next Device DA1 DATA IN From Signature Controller or Previous Device Volume seltir Default = High volury Cut for low volurr 24 Vdc In - From power Supply or previous base Data In From Signature controller or previous device lone setting )efauil = Temporal pattern ut for Steady lone To configure output returns or tare, cut the dr,t board as Shown. 24Vdc out To next base or EOL relay Data out To next Signature device Page 3ot4 DATA SHEET K85001-0269 Not to be used for Installation purposes, Issue I Specifications Sensing Element Photoelectric - Light Scattering Principle Storage & Operating Environment Air Velocity Range: 0 to 5,000 ft/min (0 to 25.39 m/s); Humidity: 0 to 93% RH, Non-Condensing Operating Temp: 32"F to 120"F (0"C to 49"C); Storage Temp: -4"F to 140"F (-20"Cto 60"C) Sensitivity Range ULI/ULC - 0.67% to 3.77% obscuration/foot User Selected Alarm Sensitivity Settings Most Sensitive: 1.0%/ft.; More Sensitive: 2.0%/ft.; Normal: 2.50/o/ft.; Less Sensitive: 3.0%/ft.: Least Sensitive: 3.5%/ft. Pre-alarm Sensitivity 5% increments, allowing up to 20 pre-alarm settings Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) (peratingCi) çQuiescent: 45pA @ 19 V. Alarm: 45pA @ 19 V. Pulse Current: 100 pAJ (sec During Communication: 9mAm Construction & Finish High Impact Engineering Polymer - White Compatible Mounting Bases GSA-SB Standard Base, GSA-RB Relay Base, GSA-lB Isolator Base, GSA-AB4, GSA-AB4G Audible Bases LED Operation On-board Green LED - Flashes when polled. On-board Red LED - Flashes when in alarm. Compatible Remote Red LED (model GSA-LED) Flashes when in alarm. Compatibility Use With: SIGNATURE Loop Controller Address Requirements Uses one Device Address eKidde Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: Kidde.com/EngineeredSystems Kidde is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Agency Listings UL, ULC, MEA, CSFM, FM UL Listed Spacing 30 ft Ordering Information Catalog Description Ship Wt. Number lbs (kg) GSA-PS Intelligent Photoelectric Detector - ULJULC Listed 0.5 (.23) Accessories GSA-SB Detector Mounting Base - Standard GSA-SB4 4-inch Detector Mounting Base c/w GSA-TS4 Trim Skirt GSA-RB Detector Mounting Base w/Relay GSA-RB4 4-inch Detector Mounting Base wlRelay, c/w GSA-TS4 Trim Skirt 0.2 (.09) GSA-lB Detector Mounting Base w/Fault Isolator GSA-1B4 4-inch Detector Mounting Base w/ Fault Isolator, c/w GSA-TS4 Trim Skirt GSA-LED Remote Alarm LED GSA-AB4G Audible (Sounder) Base .3(0.15) GSA-TS4 Trim Skirt (supplied with 4-inch bases) .1 (.04) Page 4 of 4 DATA SHEET K85001-0269 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN: Models and GSA-PHS photoelectric smoke detectors. Model GSA-PHS employs an integral 135F fixed temperature heat sensor. This heat sensor is a supplementary device to the smoke detector and is not approved as a required heat detector. Refer to listee's printed data sheet for additional detailed product description, installation and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's listed fire alarm control units and Model GSA Series bases (CSFM Listing No. 7300-1483:122). Model GSA-PS may be suitable for installation directly in the duct with the velocity range from 0-5000 feet/mm NOTE: Model SlGA-PHS is notintended for use in lieu of a required heat detector Formerly 7272-1388:186 XLF: 7272-1657:0126 0 Rev. 6-9-11 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division GSA-M278 X50-148713: nUL <~~ @ 0139 IVIEA I S2318 'Pr Intelligent Initiating C .Unitedjechnologies =-557jp:a~tlble Mpontrolystems WAM Technology that saves lives Manual Pull Stations GSA-M270, GSA-M270P, (SA-M2 7) Overview The GSA-M270 and GSA-M278 series Manual Pull Stations are part of Kidde's Signature Series system. The GSA-M270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape. They are made from die-cast zinc and finished with red epoxy powder-coat paint complemented by aluminum colored stripes and markings. With positive pull-lever operation, one pull on the station handle breaks the glass rod and turns in a posi- tive alarm, ensuring protection plus fool-proof operation. Presignal models (GSA-M270P) are equipped with a general alarm (GA) keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is not required for proper operation. Kidde's double action single stage GSA-M278 station is a contem- porary style manual station made from durable red colored lexan. To initiate an alarm, first lift the upper door marked "LIFT THEN PULL HANDLE", then pull the alarm handle. Standard Features Note: Some features described here may not be supported by all control sys- tems. Check your control panel's Installation and Operation Guide for details. Traditional familiar appearance GSA-M270 models feature our familiar teardrop design with simple positive pull action and sturdy die-cast metal body. One stage (GA), two stage (pie-signal), and double action models GSA-M270 models are available for one or two stage alarm systems. The single stage double action GSA-M278 features a rugged Lexan housing with keyed reset mechanism. Break glass operation An up-front visible glass rod on the GSA-M270 discourages tampering. Intelligent device with integral microprocessor All decisions are made at the station allowing lower com- munication speed while substantially improving control panel response time. Less sensitive to line noise and loop wiring properties; twisted or shielded wire is not required. ADA Compliant Meets ADA requirements for manual pull stations. Electronic Addressing with Non-volatile memory Permanently stores programmable address, serial number, type of device, and job number. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. Automatic device mapping Each station transmits wiring information to the loop control- ler regarding its location with respect to other devices on the circuit. Stand-alone operation The station inputs an alarm even if the loop controller's polling interrogation stops. Diagnostic LEDs Status LEDs; flashing GREEN shows normal polling; flashing RED shows alarm state. Designed for high ambient temperature operation Install in ambient temperatures up to 120 °F (49 "C). Page 1 of 4 DATA SHEET K85001-0279 4tt I tx i* i tin ut.idLt'nn Irpo.i Issue 1 Application The operating characteristics of the fire alarm stations are deter- mined by their sub-type code or "Personality Code". NORMALLY- OPEN ALARM - LATCHING (Pesonality Code 1) is assigned by the factory; no user configuration is required. The device is configured for Class B IDC operation. An ALARM signal is sent to the loop controller when the station's pull lever is operated. The alarm con- dition is latched at the station. Compatibility Signature Series manual stations are compatible only with Kidders Signature Loop Controller. Warnings & Cautions This device will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Typical Wiring The fire alarm station's terminal block accepts #18 AWG (0.75mm2) to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Wiring Notes Refer to Signature Loop Controller manual for maximum wire distance. 2. All wiring is power limited and supervised. PEAR VIEW of 278 Red LTD Green LED (Aio,m/Acth,e) (NO,md) S Testing & Maintenance To test (or reset) the station simply open the station and operate the exposed switch. The GSA-M270 series are opened with a tool; the GSA-M278 requires the key which is supplied with that station. The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. f DAJAIN(+)> 1 DATA IN(-) > From Signature Controller or Previous Device DATA OUT (+) DATA OUT C.) To Next Device Figure 4. Single Stage Systems REAP VIEW of 270P.270PB 1:9 C3 .5 . (Normal) RedLED Green LED (Alarm/Active)-e) 18 ________ _____t43 0 0 a CM ( DATA IN C,)> DATA OUT I DATAIN(-) 9 p DATA OUT 1-) 1 From Signature Controller To Next Device or Previous Device I,\ Figure 5. Two Stage Systems S Page 2 of 4 DATA SHEET K85001-0279 Not to be used for Installation purposes. Issue 1 Dck ole gg?e ltch Key-Latch Cover Release Gloss Pod OPEN Compatible Electrical Box Compatible Electrical Box N,. Cover 4 Re?easr Screw H W d' -k-- kfUJ o Glass Rod Release Lever 0 Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21/2 inch (64 mm) deep 1-gang boxes. Two stage presignal (270P) models require 1½ inch (38 mm) deep 4-inch square boxes with 1 -gang, ½-inch raised covers. Openings must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-C-13; in Canada, use Iberville Model Cl- 52-C-49-1/2. All models include terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Kidde recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Figure 1. GSA-M278 installation Figure 2. GSA-M270 installation Cover Release Figure 3. GSA-M270P installation Page 3 of 4 DATA SHEET K85001-0279 Not to be used for installation purposes. Issue I fl rKidde ~~Ml Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: Kidde.com/EngineeredSvstems Kidde is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Specifications S Catalog Number GSA-M270 GSA-M270P, GSA-M278 Description Single Action Single Action -Two Double Action - One Stage Stage (Presignal) - One Stage Addressing 1 Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Operating Current Standby = 250pA Standby = 396iA (Standby = 250pA) 6ctivated Activated = 400pA Activated = 680iA 400pA) Construction & Finish Diecast Zinc - Red Epoxy Lexan - Red with with aluminum markings white markings Type Code i Factory Set Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Operating Temperature: 32"F to 120'F (O"C to 49"C) Storage and Operating Storage Temperature: -4"F to 140"F (-20'C to 60'C) Humidity: 0 to 93% Environment RH On-board Green LED - Flashes when polled LED Operation On-board Red LED - Flashes w hen in alarm Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM, FM Ordering Information Ship Catalog Wt lbs Number Description (kg) GSA-M270 One Stage Fire Alarm Station, English Markings - ULJULC Listed Two Stage (Presignal) Fire Alarm Station, English Markings GsA-M270P 1 (0.5) - ULIIJLC Listed (a57!) Double Action (One Stage) Fire Alarm Station, English Markings - UL,ULC Listed Accessories 276-GLR 20 Glass Rods - for GSA-M278 series Page 4ot4 DATA SHEET K85001-0279 Not to be used for Installation purposes. Issue 1 C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: :0139 Page 1 of I 7150 7150 -- FIRE ALARM PULL BOXES MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com Models GSA-M270 and GSA-M270P and GSA-M278 non-coded, intelligent manual pull stations. Unit consists of a listed pull station and a remote transponder. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name or Edwards, Edwards Systems Technology (EST), model number, electrical rating and UL label. APPROVAL: NOTE: XLF: Listed as manual pull stations for use with separately listed compatible fire alarm control units. These manual pull boxes meet* the requirements of UL Standard 38, 1999 Edition and California amendments. FORMERLY: 7150-1388:194 7150-1657:0129 *Corrected 03-17-15 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 2017) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Wo Intelligent Input-Output rc Technology that saves lives Input Modules GSA-CT1, GSA-CT1 HT, GSACT2, GSA-MCT2 MEA - 7300-1483: 0115 . GSA-CT1/2 0 GSA-MCT2 S3424 Overview The GSA-CT1 Single Input Module, GSA-CT1 HT High Tempera- ture Single Input Module and GSA-CT2/GSA-MC:T2 Dual Input Modules are intelligent analog addressable devices used to con- nect one or two Class B normally-open Alarm, Supe;'visory, or Monitor type dry contact Initiating Device Circuits (lDC). The actual function of these modules is determined by the "persc.na- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The GSA-Cu, GSA-CTIHT and GSA-CT2 mount to standard North American 1-gang electrical boxes, making ThEm ideal for l-- cations where only one module is required. Separate I/O and data loop connections are made to each module. The GSA-CT1 HT module operates at an expanded temperature range of 32 "F to 158 "F (0 "C to 70 "C) for thcse aplications requiring more extreme environmental temperature variaticn. The GSA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the GSA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-moduie UIO motne- boards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclosures. Standard Features Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer select one of four 'personality codes" to be downloaded to the mod- ule through the loop controller. GSA-CT1HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the Signature Program/Service Tool. There are no switches or dials to set. Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 4 K85001 -0241 C Issue I Signature Series Overview The Signature Series intelligent analog-addressable system from Kidde Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, .etwork and non-network control panels, and user-friendly mainte- ance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. Installation GSA-CT1, GSA-CTIHT and GSA-CT2: modules mount to North .1101111~merican 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 m) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm' to 0.75 mrvire size. Compatible electrical box Wall plate, white (1 -gang) UIO Motherboard 6-32 Sell-tapping screws Plug-in (1.110) >Captive Module screws e6 Flat washers Li Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the Signature Pro- gram/Service Tool. Kidde recommends that this module be installed according to lat- est recognized edition of national and local fire alarm codes. Application The duty performed by the GSA-CT1 and GSA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the GSA-CT1. Two per- sonality codes can be assigned to the GSA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on GSA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. LED viewing ports-4— •\ GSA-MCT2: mount the UIO motherboard inside a suitable Kidde enclosure with screws and washers provided. Plug the GSA- MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see ring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Page 2 of 4 NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- ality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. K85001-0241 Issue TB2 ui.iuic Listed 47K1 EOL Green LED (Normd) Tat . DATA OUT (+) DATA OLJT(-) To Next Device Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 IJF per Circuit For Design Reference: Wire Size I Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) #14 AWG (1.50 mm2) #12 AWG (1.50 mm) Typical N.O. Initialing Device Typical N.O. Initiating Device INPUT 1 INPUT 2 4,000 ft (1,219 m) I&AA4 style B (class B) Red LED (Alarm/Active) f DATA IN(+)>- 1, DATA IN(-) > From Signature Controller or Previous Device I 1 1 7 uiiuic Listed Style B (Class B) 47K1 EOL A A A Red LED (Alarm/Active) f DATA IN(+)> 1, DATAIN(-)> From Signature Controter or Previous Device , ¶-t S I • UL/ULC Usled 47 EOL 0 0 Green LED (Norma) DATA OUT DATA To Next Device GSA-CT1 GSA-CT1 HT NOTES Maximum 25 Ohm resistance per wire. Maximum #12 AWG (2.5 mm2) wire: Minimum #18 AWG (0.75 mm2). Refer to Signature controller installation sheet for wiring specifications. Maximum 10 Vdc @ 350 iA The GSA-U106R and the GSA-U102R do not come with TB14. 6 All wiring is supervised and power-limited. - 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of Kiddes Signature Series intelligent pro- cessing and control platform. They are compatible with VM, and VS Series control panels. GSA-CT2 rypkol NO IniIiothnç D.in. UIJULC Lhond Inp4tI UtflJLCLint.d 4704101. N7KW€OL 1234 A 1111 I oeion.qnd 101 4.1 )1071,e, ,IgIeg n,oy,nqg4e ionnecUon,, Gmn ISO IN-11 7615 Red LEO llrtionl gel. "\•Noronoeonionnonj,onpen genlln,00 ,eq,ir.dfonl4crl. GSA-MCT2 Page 3of4 DATA SHEET K85001-0241 Not to be used for installation purposes. Issue 1 Specifications Catalog Number GSA-CT1HT I GSA-Cu SA-CT2 I GSA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Activated = 400iJA Standby = 396pAJ Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21/2 inch (64 mm) deep one-gang box- es and 11/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and GSA-MP mounting plates UI02R/6R/6 Motherboard Operating Environment 32°F to 158°F (0°C to_70°C) °F ')r° Th°(' + AO to ' ° Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Both LEDs - Glow steady when in alarm Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM re~m?.~Kidde Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: Kidde.com/EngineeredSystems Kidde is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Ordering Information Catalog Description Ship Wt. Number lbs (kg) GSA-CT1 Sinole Inout Module - UL/ULC Listed 0.4 (0.15) GSA-CT1HT Single Input Module High Teperature Operation UL/ULC Listed 0.4 (0.15) (çj2 Dual Input Module - UL/ULC Listed 0.4(0.15) GSA-MCT2 Dual Input Pluq-in (UIO) Module - UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0(0.6) GSA-UI02R Universal Input-Output Module Board w/Riser Inputs 0.32 (0.15) - Two Module Positions GSA-UI06R Universal Input-Output Module Board w/Riser Inputs 0.62 (0.28) - Six Module Positions GSA-UI06 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) MFC A Multifunction Fire Cabinet - Red, supports Signature Module 7.0(3.1) - Mounting Plates GSA-MB4 Transponder Mounting Bracket (allows for mounting 0.4 (0.15) two 1-gang modules in a 2-gang box) Page 4of4 DATA SHEET K850010241 Not to be used for installation purposes. Issue 1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE . LISTING No. 7300-1483:0115 Page I of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.conover@fs.utc.com DESIGN Models GSA CCI GSA CC2 GSA CTI GSA CT2, GSA CR GSA CRR GSA-UM GSA-MMI, GSA-WTM, GSA-IM, GSA-MCC2, GSA-MCT2, GSA-MCR, GSA-MCRR, GSA-MAB, GSA-MCCI, GSA-MOM remote transponders; Models GSA-U106, GSA-U106R and GSA-UI02R motherboards. Models GSA-CC1S and GSA-MCCIS Auto-Sync Output Modules. Models MFC-A and MFC-AO enclosures. Models GSA-MPI, GSA-MP2 and GSA-MP2L mounting plates. Model GSA-CR2 Control Relay Module. *GSA..CRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. RATING: 15.2- 19.95 VOC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote transponders for use with separately listed compatible fire alarm control units. XLF: 7300-1657:0121 *Rev. 03-29-16 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other is Date Issued: July 01, 2016 Listing Expires June 30, 2017, Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division fl RM-2 Relay Module Installation Instructions The RM-2 Relay Module is used as an end-of-line (EOL) power supervision module for 4-wire smoke detectors. The RM-2 is used with the Polarity Reversal Module PRM- 4W and DSC FSA-41 0 series smoke detectors. When the PRM-4W reverses polarity on the smoke detector loop to activate all smoke detector sounders, the RM-2 Relay will continue to operate normally (regardless of input power polarity). Refer to the PRM-2W/4W Polarity Reversal Module Installation Instructions Technical Specifications: Operating Voltage Range: ............................................................. 1OVDc to 30VDc Relay Contact Rating: ..................................................................... 2A@3OVDCNAC CurrentRating ..............................................................................................i25iTA Operating Environment: ................................................... 0°C - 49°C (32°F - 120°F) .....................5% - 93% RH (non-condensing) Size (H x W x D) ...................................28.5 x 86 x 21 mm / 1 x 3 '8 x in. Terminal Wire Gauge: ............................................................................ 14-22 AWG Connection Diagram Run the connection wires through the wiring holes on the back of the unit. Mounting . To mount the unit, remove the plastic cover and secure the unit to the desired loca- tion with the screws provided. Replace the cover. The module can also be mounted inside a standard 4" electrical box (1.5" deep) if required by the installation. Please refer to the diagrams below: 4-WIRE SMOKE DETECTORS PRM-4W FSA-410 Series Polarity Reversal Module 4-wire Smoke Detector Control Panel P+ P- I I 111111 Zx Corn + + - NO C 12 VDC-1 Panel EOLF BLK eIi cj o IIIHNC (a L11 'e1 I COM 1 DSCRM-2Relay IIII II .....- I. NO 0 Mounting of the Relay in an Electrical Box 4-Wire Smoke Detector FSA-41 Ox Smoke Detector Mounting Plate Power Supervision Relay RM-2 Electrical Box (1.5" deep) LIMITED WARRANTY Digital Security Controls Ltd. warrants that for a period of twelve months fron the date of purchase, the is product shall be free of defect in materials and workmanship under normal use and hat in fulfilment of any breach of such warranty. Digital Security Controls Ltd. shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the control of Digital Security Controls Ltd. such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out of abuse, alteration or improper application of the equipment. The foregoing warranty shall apply only to the orig'nal buyer, and is and shall be in lieu of any a A all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Digital Se- curity Controls Ltd. This warranty contains the entire warranty. Digital Security Controls Ltd. neither as- sumes, nor authorizes any other person purportng to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. In no event shall Digital Security Controls Ltd. be Lable for any direct, indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the bLyer in connection with the purchase, installation or operation or failure of this product. WARNING: Digital Security Controls Ltd. recommerds that the entire system be completely tested on a reg- ular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electri- cal disruption, it is possible for this product to fail to perform as expected. ©2003 Digital Security Controls Ltd. II II liii IllIllIllIllIll III Toronto, Canada • www.dsc.com Printed in Canada 2903440FtJO2 Direct all comments concerning this publicatioi to pubs@dscltd.com [1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (T300-1273:0127 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Security Controls95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: Models PRM-2W, -2WC (for 2-wire smoke detectors), PRM-4W, -4WC(for 4-wire smoke detectors) power reversal modules and 2 power supervision relay modules. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: 09-30-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires (June 30, 201) Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S p 0 p SIGNAUNG LISTED Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1/4 deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard 3h"cat 30 key lock other lock as- semblies available This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. S J FAD ACE-Il FIRE ALARM - The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords Solid stainless steel piano hinge and other critical system information. Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information Space Age Electronics, Inc. 1N DO C M CdMPANY adelS.A. REGISTERED ______ 800.486.1723 Toll Free S 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2009 No Excuses, Just Solutions! ED0549 L110559 Rev.D 1/2 JSPACE AGE EYELECTRONICS, INC. IDS pecifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. T1 3 USB Storage Interface Requires Standard USB-B Connector - Key Ring Hooks usiness Card Holder I J ,..AC1At Fo..,.0b0.000 00.EJ031tl0W. 01 own Prapn,ty ,,fon,,atlon Mlnln,on, Rnqolr,d Doconoanlollon (SIG-FUN) Oil San, Iii) ou— Certlllcatlon. and Approvals 16.1 Syslnm InvIallaiJon Congnctov 0000 Sd.*aaS0.S j,.. v--a--an--n nglw0) Ofl, l0.0)anlrafla. 16.5 Alh00lly Having JusdlUi0n nan. 001555.05000,, 00w00an.00vn000 0)fl OSIan 0SA0,0.00tW.S005SOISSISSAI0)L0Ifl1A2 0____ .0* a 0.0.14 0) At 1*105, Egolpo1001 lnlo,040lon II 10. .0 a*101*. In sAtAn .4 . anal. - 100P Sns.anOiI4 0*40.1.0, ..Io. LTI0644 0.0.1 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # E00479 for legal disclaimer ED0549 LT1 0559 Rev.D 2/2 Space Age Electronics, Inc. S www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE CAL %1RE A LISTING No. (,7'300-0553:O10 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IF1, IFX/A and IFXJD enclosures. ModelsCE-11 ACE-12 and ACE-13, *ACE2424 *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. S 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not WN an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires CJune3O,2Oi7j Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division