HomeMy WebLinkAbout7201 RANCHO SANTA FE RD; ; AS080041; PermitCity of Carlsbad Sprinkler Permit Permit No: AS080041 7201 RANCHO Job Address: SANTA FE RD Permit Type: SPRINK Parcel No: 2236172400 Lot #: 0 Status: ISSUED Applied 3/25/2008 Approved: 3/26/2008 Reference No.: Issued: 3/26/2008 PC #: Inspector: Project Title: CITY FIRE STATION #6 FIRE SPRINKLER SYSTEM INSPECTIONS-NO CHARGE Applicant: AZTEC FIRE PROTECTION 8109 COMMERCIAL STREET LA MESA, CA (619) 464-5625 Owner: CITY OF CARLSBAD PUBLIC AGENCY Fees ($) Add'I Fees ($) Total ($) Balance ($) 0 0 0 0 Conterminous 48 States 2005 ASCE 7 Standard Latitude = 33.0503 Longitude = -117.1359 Spectral Response Accelerations Ss and SI Ss and SI = Mapped Spectral Acceleration Values Site Class B- FaI.0,Fv1.0 Data are based on a 0.01 deg grid spacing Period Sa (sec). (g) 0.2 1.031 (Ss, Site Class B) 1.0 0.380 (SI, Site Class B) Conterminous 48 States 2005 ASCE 7 Standard Zip Code = 92009 Spectral Response Accelerations Ss and SI Ss and SI = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.01 deg grid spacing. Period Centroid Sa (sec) (9) 0.2 1.180 (Ss, Site Class B) tO 0.444 (SI, Site Class B) Period Maximum Sa (sec) (g) 0.2 1.350 (Ss, Site Class B) 1.0 0.512 (SI, Site Class B) Period Minimum Sa (sec) (g) .0.2 1.074 (Ss, Site Class B) 1.0 0.405 (SI, Site Class B) AScco4t These plans have been reviewed for apparent coinpiiau' with the current appliCa1C codes and standards in totce in the jurisdiCti0I The owner or contractor may utilize this review in support oUafl application tor a building I wit the express ndersa11dmg that this review in no way relieves the owne5 or contractor or their prolessioflal engineer or architect for sole respotiiiihilitY for lull compliance with said codes and standards. including she huildiflc0 or for any responsihilty for defIcieflCiC errors. fli5SI0tt5 or iigligeflce in these plans whether or not noted in this review. Reviewer: RECOMMEND APPROVAL RF'MMENI) APPROVAL AS NOTED O 5eY APPR9j1AS SUBMITTED CAR1 DEPART! ENI FILE COPY FLOW TEST SUMMARY REPORT----'gel LOCATION:7201 RANCHO SANTE FE DATE: 12-5-07 CARLSBApI CA TIME: Static Hydrant Number: Flowing Hydrant Number: Elevation: 2 Elevation: 2 01st. Between Hydrants: 300 Diameter of Main: 8 Outlet Diameter: 2.50 in Number flowing: 1 Coeff.: 0.90 Static pressure: 155.00 psi Residual pressure: 120.0U psi PILuL Reading; 60.00 psi Flow: 1300.2 gpm Flow at 20 psi: 2697.0 gpxn GRAPH: PSI 200 + I 180 + I ]/Normal Pressure-No Flow-155.00 psi I 160 S I 140 I \\\\/Test Flow-1300.2 gpm-120.00 psi I 120 + R... I 100+ .... I 1 .... I 80+ .... I 60 + 40 + I 20 + Avail. Flow @ 20 psi2697.0 gpm * ' 0 +-+---+----+-----+------+--------+--------+---------+-----------+ 600 900 1200 1500 1800 2100 2400 2700 3000 FLOW (GPM) NOTES; Flowing hydrant is assumed to be on a circulating main or downstream of the pressure test hydrant on a dead-end system. Flow analysis assumes a gravity flow system with no distribution pumps and having no demand, other than the test flow. Distance between hydrants, elevations & main diameter are for information only. FL@ TEST SUMMARY REP0RT'ge2 200.0- 160. 0 j )Normal Pressure-No Flow-155.00 Ps 140.0-- G 120.04. Flow-1300.2 gpm-120.00 psi E P R 100.0.1 E S o.0 p 60.0-.- 40.0- 20.0 1650 1925 2200 2475 2750 FLOW (GPM) 0.0± 550 825 1100 1375 AZTEC FIRE PROTECTION 13109 COMMEKQ1AJj ST. LA MESA, CA 91942 HYDRAULIC CALCULATIONS FOR CARLSBAD FIRE STATION NO.6 CARLSBAD, CA FILE NIJMDER; DATE: MAR 4, 2008 ATTIC - REV 1 -DESIGN DATA— OCCUPANCY CLASSIFICATION; ORDINARY HAZARD GP.2 DENSITY: .20 GPM AREA OF APPLICATION: 1712 SQ.FT. (ENTIRE AREA) COVERA6h PER SkkLLN1cJ.,rK: 10 iq. CL. NUMBER OF SPRINKLERS CALCULATED: 24 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: .641.2 gpm TOTAL WATER REQUIRED (including hose); 891.2 gpm. FLOW AND PRESSURE (8 BOR): 641.2 gpm ( 10.9 psi. SPRINKLER ORIFICE SIZE: 1/2 1nh NAME OF CONTRACTOR: DESIGN/LAYOUT BY: RD AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER; C16, 82201 CALCULATIONS BY BASS COMPUTER PROGRAM (LICENSE # 50060566 HRS SYSTEMS, INC. TUCKER, GA 30084 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 3/4/2008FIRE SPRINKLER\CALCULATIONS\CARLSBAD FIRE STATION REV 1..SDF JOB TITLE: CARLSBAD FIRE STATION NO. 6 - REV 1 WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) ((ZPM) (PSI) (GPM) (PSI) Z 139.5 18.0 2697.0 123.8 891.2 107.6 AGGREGATE FLOW ANALYSIS TOTAL FLOW AT S0t3RCE 891.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 250.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 641.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) ('sJ:) (GPM) 1 18.0 K= 5.60 22.8 26.8 2 18.0 K= 5.60 23.0 26.9 3 18.0 K= 5.60 23.7 27.3 4 16.0 K- 5.60 25.1 28.1 5 22.3 ic= 5.60 20.8 25.6 6 22.3 K= 5.60 21.0 25.7 7 22.3 K= 5.60 21.6 26.0 8 22.3 K= 5.60 22.9 26.8 9 24.4 K= 5.60 20.0 25.0 10 24.4 K= 5.60 20.2 25.1 11 24.4 K 5.60 20.8 25.5 12 24.4 K= 5.60 22.0 26.3 13 24.4 K= 5.60 20.1 25.1 14 24.4 K= 560 20.3 25.2 15 24.4 K= 5.60 20.9 25.6 16 24.4 .ic= 5.60 22.2 26.4 17 223 c= 5.60 23.1 26.9 18 22.3 K= 3.60 23.3 27.0 19 22.3 K= 5.60 24.0 27.4 20 22.3 K= 5.60 25.4 28.2 21 18.0 K= 5.60 25.1 28.1 22 10.0 K= 5.60 25.4 28.2 23 18.0 K= 5.60 26.1 28.6 24 18.0 I@ 5.60 27.7 29.5 31 18.0 - - - - 30.7 -' - - 32 18.0 - - - - 30.8 33 18.0 -- - - 310 34 18.0 ----. 31.2 35 18.0 --- - 34.8 - -- 36 18,0 ---- 33.9 37 18.0 - - - - 33.7 - - - 41 23.8 - - - - 55.3 TR 12.0 -- -- 88.7 x 1.0 ---- 105.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/4/2008FIRE SPRINKLER\CALCULA'i'WNS\CARI.i5BAD FIRE STATION REV 1.SDF JOB TITLE: CARLSBAD FIRE STATION NO. 6 - REV 1 NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (P51) (GPM) PVC -3.0 - - - - 106.0 - - - Y -3.0 HOSE STREAM 108.4 250.0 Yl -3.0 - - - - 109.0 -- - Z 2.0 SOURCE 107.6 891.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 3/4/2008FIRE SPRINKLER\CALCULATIQNS\LARLSEAD FIRE STATION REV 1.SDF JOB TITLE: CARLSBAD FIRE STATION NO. 6 - REV 1 PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NQZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. Ncrngs (FT) (K) (PSI) (GEM) FL/FT (PSI) Pipe: 1 -26.8 1.728 EL 9.50 PE 0.2 1 16.0 3.6 22.0 20.0 3.7 120 FTC ---- PE 0.0 2 18.0 5.6 23.0 26.9 0.020 TL 9.50 PV Pipe: 2 -53.6 1.728 PL 9.50 PF U.! 2 18.0 5.6 23.0 26.9 7.3 120 FTC ---- PE 0.0 3 18.0 5.6 23.7 27.3 0.071 TL 9.50 PV Pipe: 3 -80.9 1.728 EL 9.50 PP 1.4 3 18.0 5.6 23.7 27.3 11.1 120 1T(. ---- PE 0.0 4 18.0 5.6 25.1 28.1 0.152 TL 9.50 PV Pipe: 4 -108.9 1.728 PL 4.17 PF 5.6 4 18.0 5.6 25.1 28.1 14.9 120 FTG ET PE 0.0 31 18.0 0.0 30.7 0.0 0.263 TI, 21.10 PV Pipe: 5 -108.9 3.314 PL 11.00 PF 0.1 31 18.0 0.0 30.7 0.0 4.1 120 FTG ---- PE 0.0 32 18.0 0.0 30.8 0.0 0.011 TL 11.00 EV Pipe: 6 -25.6 1.728 EL 9.50 PF 0.2 5 22.3 5.6 20.8 25.6 3.5 120 FTG ---- PE 0.0 6 22.3 5.6 21.0 25.7 0.018 TL 9..SU PV Pipe: 7 -51.2 1.77.8 P1 9.50 PF 0.6 6 22.3 5.6 21.0 25.7 7.0 120 FTC •---- PE 0.0 7 22.3 5.6 21.6 26.0 0.065 TL 9.50 PV Pipe: 6 -77.3 1.728 EL 9.50 PF 1.3 7 22.3. 5..6 21.€ 26.0 10.6 120 FTG --- PE 0.0 8 22.3 5.6 22.9 26.8 0.139 TL 9.50 PV Pipe; 9 -104.1 1.720 FL 7.75 PP 6.0 8 22.3 5.6 22.9 26.8 14.2 120 FTC ET PE 1.9 32 18.0 0.0 30.8 0.0 0.242 TL 24.68 PV Pipe: 10 -213.0 3.314 EL 6.00 PF 0.2 32 18.0 0.0 30.9 0.0 7.9 120 FTC ---- PE 0.0 33 18.0 0.0 31.0 0.0 0.038 TL 6.00 PV Pipe; 11 -2.0 1.728 PL 9.50 PP 0.2 9 24.4 5.6 20.0 25.0 3.4 120 FTG ---- PE 0.0 10 24.4 5.6 20.2 25.1 0.017 TL 9.50 PV Pipe: 12 -50.2 1.728 PL 9.50 PF 0.6 10 24.4 5.6 20.2 25.1 6.9 120 FTG ---- FE 0.0 11 24.4 5.6 20.8 25.5 0.063 TL 9.50 PV 1. 9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 UAT: 3/412008F1RE SPRINKLER\CALCULATION5\ClLBAD FIRE STATION REV 1.SDF JOB TITLE: CARLSBAD FIRE STATION NO. 6 - REV 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ.. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -75.7 1.728 PL 9.50 PF 1.3 11 24.4 5.6 20.8 25.5 10.4 120 FTG ---- PE 0.0 12 24.4 5.6 22.0 26.3 0.134 TL 9.50 PV Pipe: 14 -102.0 1.728 FL 9.75 PF 6.2 12 24.4 5.6 22.0 26.3 14.0 120 ?'TG ET PE 2.8 33 18.0 0.0 31.0 0.0 0.233 TL 26.68 PV Pipe: 15 -315.0 3.314 PL 2.00 PF 0.2 33 18.0 0.0 31.0 0.0 11.7 120 FTG PE 0.0 34 18.0 0.0 31.2 0.0 0.079 TL 2.00 PV Pipe: 16 . -25.1 1.728 FL 9.50 PT 0.2 13 24.4 5.6 20.1 25.1 . 3.4 120 FTG ---- FE 0.0 14 24.4, 5.6 20.3 25.2 0.017 TL 9.50 PV Pipe.; 17 -50.3 2.720 PL 9.50 PT 0.6 14 24.4 5.6 20.3 25.2 6.9 120 FTG ---- FE 0.0 15 24.4 5.6 20.9 25.6 0.063 TL 9.50 PV Pipe: 18 -75.9 1.728 FL 9.50 PF 1.3 15 24.4 5.6 20.9 25.6 10.4 120 FTC --- PE 0.0 16 24.4 5.6 22.2 26.4 0.135 TL 9.50 ?V Pipe: 19 -102.3 1.728 FL 9.75 PT 6.3 16 24.4 5.6 22.2 26.4 14.0 120 FTG ET PE 2.8 34 18.0 0.0 312 0.0 ' 0.234 P1 26.68 PV Pipe: 20 -417.3 3.314 FL 5.50 PF 3.6 34 18.0 0.0 31.2 0.0 15.5 120 FTG T FE 0.0 35 18.0. 0.0 34.8 0.0 0.133 TL 27.34 PV Pipe: 21 223.9 3.314 FL 0.50 PF 0.9 35 18.0 0.0 34.8 0.0 8.3 120 FTG T FE 0.0 36 18.0 0.0 33.9 0.0 , 0.042 TL 22.34 PV Pipe: 22 ' -26.9 1.728 PL 9.50 PF 0.2 17 22.3 5.6 23.1 26.9 3.7 120 FTG ---- PE 0.0 18 22.3 5.6 23.3 27.0 0.020 TL 9.50 PV Pipe: 23 -53.9 . 1.728 FL 9.50 PT 0.7 18 22.3 5.6 23.3 27.0 7.4 120 FTC ---- FE 0.0 19 22.3 5.6 24.0 27.4 0.072 'ri., 9.50 PV Pipe: 24 . -81.4 1.728 PL 9.50 PF 1.5 19 22.3 5.6 24.0 27.4 11.1 120 FTG ---- PE 0.0 20 ' 22.3 5.6 25.4 28.2 0.153 TL 9.50 PV Pipe: 25 . -109.6 1.728 PL 7.75 PF 6.6 20 22.3 5.6 25.4 28.2 15.0 120 FTC .ET FE 1.9 36 18.0 0.0 33.9 0.0 0.266' TL 24.68 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 3/4/2008F1RE SPRINKLER\CALCULA'r1ONS\CARL5B1D FIR STATION REV 1.3DF JOB TITLE: CARLSBAD FIRE STATION NO. 6 - REV 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (Ic) (PSI) (GPM) FL/FT (PSI) Pipe: 26 1.14.3 3.314 PL 11.00 PF 0.1 36 18.0 0.0 33.9. 0.0 4.3 120 FTG ---- PE 0.0 37 18.0 0.0 33.7 0.0 0.012 TL 11.00 PV Pipe: 27 -28.1 1.728 Pt 9.50 PF 0.2 21 18.0 5.6 25.1 28.1 3.8 120 FTG ---- PE 0.0 22 18.0 5.6 25.4 28.2 0.021 TL 9.50 PV Pipe: 28 -56.3 1.729 PL 9.50 P1? 0.7 22 18.0 5.6 25.4 28.2 7.7 120 FTG ---- PE 0.0 23 18.0 5.6 26.1 28.6 0.078 TL 9.50 PV Pipe: 29 -84.9 1.728 PL 9.50 PF 1.6 23 18.0 5.6 26.1 28.6 11.6 120 FTG --- .- PE 0.0 24 18.0 5.6 27.7 29.5 0.166 TL 9.50 PV Pipe: 3U -114.3 1.728 FL 4.17 FE' 6.1 24 18.0 5.6 27.7 29.5 15.6 120 FTG ET PE 0.0 37 18.0 0.0 33.7 0.0 0.288 TL 21.10 PV Pipe: 31 -641.2 3.314 FL 15.83 PF 23.0 35 iO0 0.0 34.8 0.0 23.8 120 FTG 'lET FE -2.5 41 23.8 0.0 55.3 0.0 0.293 TL 78.43 PV Pipe; 32 -641.2 3.314 PL 35.17 PP Z.3 41 23.8 0.0 553 0.0 23.8 120 FTG 6E PE 5.1 TR 12.0 0.0 88.7 0.0 0.293 TL 96.31 PV Pipe: 33 -641.2 3.314 PL 12.00 FE' 12.5 TR 12.0 0.0. 88.7 0.0 23.6 120 FTG 3E FE 4.8 X _. 1.0 0.0 105.9 0.0 0.293 TL 42.57 PV Pipe: UG -641.2 6.280 PL 15.00 PF 0.4 X 1.0 0.0 105.9 0.0 6.6 140 FTG E PE 1.7 PVC -3.0 0.0 108.0 0.0 0.010 TL 39.00 PV Pipe: 35 -641.2 7.980 PL 64.00 PF 0.4 PVC -3.0 0.0 108.0 0.0 4.1 150 FTG ETG FE 0.0 Y -3.0 H.S. 108.4 250.0 0.003 TL 146.00 PV Pipe: 36 -891.2 7.980 FL 90.00 PF 0.6 Y -3.0 H.S. 108.4 250.0 5.7 150 FTG E PE 0.0 Yl -3.0 0.0 109.0 0.0 0.005 Tlj 116.00 PV Pipe: 37 -891.2 6.280-PL 15.00 PF 0.8 Yl -3.0 0.0 109.0 0.0 9.2 140 FTG EG FE -2.2 Z 2.0 SRCE 107.6 (N/A) 0..018 TL 44.00 PV 1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 3/4/2008iiIt SRiNKLJR\eAJ..(.ULA'1iONs\UARLSBAD FIRE STATION REV 1.SDF JOB TITLE: CARLSBAD FIRE STATION NO. 6 - REV 1 NOTES (MASS): C41ul.LiOii WeLe pez.fui.:ud by LJte MASS 7.9 computer program under license no. 50060566 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.081 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 23.8 ft/sec at pipe 31. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: D MATERIAL;. DIRON HWC; 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Eli Tee LngEil ChkVlv BfyVlv GatVlv NPTee 6.280 24.00 52.00 16.00 55.00 17.00 5.00 52.00 PAGE: E MATERIAL: PVC150 HWC; 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Eli Tee LngE1i ChkVlv BfyVlv GatVlv NE'Tee 7.980 . 26.00 50.00 19-60 . 64-00 17.00 6.00 50.00 PAGE: G MATERIAL: D-FLW HWC: 120 Diameter Equivalent titting Lengths in ieet (in) E T L C B G A D N Eli Tee LngE1l ChlV1v BtyVlv GatVlv AlmChk DPVlv 1.728 5.64 11.29 2.82 12.70 8.47 1.41 14.11 14.11 0.00 3.314 10.'19 21.84 7.28 23.29 14.56 1.45 14.56 14.56 0.00 -J '.1 0 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE 3/4/2008FIRE SPRINKLER\CALCULATIONS\CARLSBAD FIRE STATJ.UN REV 1.5DF JOB TITLE: CARLSBAD FIRE STATION NO. 6 - REV 1 0 0 0 0 0 0 0 0 0 -.4 0 0 0 0 0 0 0 0 0 (N 0OD (N ri 0bLrz) Z(fl--4-- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 3/4/2008FIRE SPRINKLER\CALCULATIONS\CARLSBAD FiRs STATION REV 1.SDF JOB. TITLE: CARLSBAD FIRE STATION NO. 6 - REV 1. WATER SUPPLY CURVE 1441- * 132+ \ I \ I \ 0 120+ 1 \ 108+ X \ I \ 1 \ P96+ RI E I \ S I \ S84-i- UI RI \ E \ 72+ P I Si 160+ ) I .1 48+ \ 361- 24+ LEGEND I X = Required Water Supply * I 107.64 psi @ 891.2 gpm 12+ I 0 = Available Water Supply 123.94 psi 9 891.2 gpm +------+---------4---------+---------+-----------+ 8001200 100 2000 2400 2800 3200 3600 4000 FLOW (GPM) <-18.0 psi @ 2697 gpm Flow Test Point -I. 'oss FIRE & WATERWORKS Series ES-A-3000SS A A M E S Double Check' l) e tect( ) r As seinbi 4 . Sizes: 21/2 - 12'(5'— 300mm). 4fr '4. Fe'aturill raienxeu Caw-Check Asseii valve pvides low heud oss Shdrt I yIcrigth is deally suited for retrofit installafions .. of competitive denigns redicir . ri n tnllot .n and hippin ost . a Ness step! con trucion priies r long term corroson protector arid n a mum strierigth Series 3000SS Double Check Detector A rnUrrp designed for use in accordance inq!e tc p access cover with t,o bolt 9r00ved yl&db3iing for ease of with water utility non healti grd coi tarnnt ri J ens It is mandatory to maintenance prevent the reverse flow of fire protetion system substances, i.e., glycerin wetting No special tools required for servicing agents, stagnant water and water of non-potable quality from being pumped or. Compact construction allows icr siphoned into the potable water supply. smaller vaults and enclosures . . . . Furnished with 51s" x 3/4" brcnze meter Specifications (gpm or cfm) A Double Check Detector Assembly shall be installed on. fire protection systems when Detects underground leaks and . connected to a potable water supply. Degree of hazard present is determined by the unauthorized water use local authority having jurisdiction. The main valve body shall be manufactured from Maybe installed horizon-:al or ortical .300 Series stainless steel to provide corrosion resistance, 100% lead free-through the "flow up" position waterway. The double check detector assembly consists of two independently operating, Available Models spring loaded check valves, two UL, FM, OSY resilient seated gate valves, and bypass assembly. The bypass assembly consists of a meter (cubic ft. or gallons), a double check Suffix . including shutoff valves and required test cocks. Each cam-check shall be internally - . IncidrI and nrnvrdp a nnsitivp i-kin tight closure mriincxt rPurrrm flowCam-check LG - less shutoff valves. stainlessincludes a steel cam art and spring, rubber faced dc and areplaceable OSY - ULJFM outside stem and yoke seat. There shall be no brass or bronze parts used within- the cam-check valve resilient seated gate valvs assembly. The check valve seats shall be of molded thermoplastic construction. The "OSY FxG - flanged inlet gate connection and use of seat screws as a retention method is prohibited. All internal parts shall be grooved outlet gate connection accessible through a single cover on the valve assembly. The valve cover shall be held "OSY GxF - grooved inlet gate connection in place through the use of a single grooved style two-bolt coupling. The bypass line and flanged outlet gate connec- shall be hydraulically sized to accurately measure low flow. The bypass line shall con- tion. . . sist of a meter, a small diameter double check assembly with test cocks and isolation "OSY GxG - grooved inlet gate connection and valves. The bypass line double check valve shall have a single access cover, two grooved outlet gate connection independently operating modular poppet check valves, and top mounted test cocks. CFM - cubic feet per minute The assembly shall bean Ames 3000SS. GPM - gallons per minute meter . iia en s . Available with grooved NRS gate vaves - consult factory" - . All internal metal parts: 300 Series stainless steel, Main valve body: 300 Series stainless Post indicator plate and operatir.g nit . steel, Check assembly: Noryl® Flange dimension in accordance with AWWA Class D. available - consult factory* Noryl® is a registered trademark of General Electric Company. "Consult factory for dimensions Job Name . Contractor Job Location . Approval Engineer . Contractor's P.O. No. Representative Ames product specifications in U.S. customar wits and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, speodications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously, or subsequently sold. www.amesfirewater.com Pressure - Temperature Temperature Range: 33°F - 110°F (5°C - 43°C) Maximum Working Pressure: 175psi (12.06 bar) Capacity Flow curves as tested by Underwriters Laboratory per UL 1469, 1996. * Rated flow **UL Tested I .i_______. uu _______. uu u• kPa psi 4" (100mm) * ** 103 15 63 12 62 9 41 21 3 80 _____________________ 0 50 100 150 200 250 300 350 400 450 500 550 600 650 708 750 gpm 171 380 570 760 950 1140 1330 1520 1170 1900 2090 2260 2470 26602850 1pm 5 10 15 fps 1.5 3 4.6 mps C (Open) I A Standards AWVVA C510-92, UL 1469 Approvals For 12° approvals consult factory. (9 0 FM c®us 1048 (sizes 21/2° - 10°, (OSY Only) OSY Only) I1.1lfl1Th OMMIMMMEMMMEMMME MOMMMMMMIMENOMM __-—____..___. L1 1 :jI,fl1ITt_ r.....i ..uiI • u••ui. •••••• --"-• tl_____l —.--- .__. l_ I. MMMMMMMMMI '1i••••••i U.. IU U•U I I._.__..__l . I _. I ••••i uui • --------- SIZE (DN)DIMENSIONSI1111 NET WEIGHT NET WEIGHT in. mm A in. mm C (OS) in. mm D in. mm G in. mm L in. mm P in. mm wlGates lb. kg. w/o Gates lb. kg. 21/2 65 37 965 16/o 416 31/2 89 10 250 22 559 121/2 318 155 70 68 31 3 80 38 965 18/a 479 33/4 95 10 250 22 559 13 330 230 104 70 32 4 100 40 1016 22/4 578 41/3 114 10 250 22 559 141/2 368 240 109 73 33 6 150 48½ 1232 301/8 765 51/3 140 15 381 271/2 699 151/2 394 390 177 120 54 8 200 521/2 1334 373/4 959 6/4 171 15 381 29½ 749 181/2 464 572 259 180 82 10 250 551/2 1410 453/4 1162 8 200 15 381 29'/2 749 191/2 495 774 351 190 86 12 300 571/2 1461 531/8 1349 91/2 241 15 381 29½ 749 21 533 1044 474 220 100 Ak A M E S FIRE &WATERWORKS IMPORTANT. Inquire with governing authorities for local installation requirements. - [Ke1900 A Division of Watts Regulator Company www.amesfirewater.com I CERTIFIED 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 **Fax: 916-928-9333 ES-A-3000SS 0513 . ©Ames Co. 2005 QvV DIMENSIONS IN INCHES OTY '' thrill NON _____WALL OPENING: -RATED ACCOMMODATES '*JL FOLLOWING e Alum flu I54 EXTINGUISHERS 5634 5644 1 Trimiess 10 1/2" 2 4 5 3/4 12 3/4" I """ 6 ___ 55i-4 5524 5534 _ 5554 : Trimless 18 irimiess3E 1 8' 73/4 Ji' 8 Cosmic 21 5E, 5X, 6E, iir1iaxy z liz, , 5 1/2, 6JIermnerf/ 2 1/2, 5) I Any Cosmic, Any Galaxy, Grenadier Sentinel 5,10, 15 Mercury 2 1/2, 5, Any Saturn E 2 1/2'Tre department vaRè I I 5814 5824 5544 Trimiess 32" 32 7 3/4" 34 1/4' I 33- 1/41=4 33" 81 1 1/2" or 2 1/2' xl 1/2' rack unit and a 2 1/2' tire department valve and a tire extinguisher I 5844 30 73/4 ' tI 8' 1 1/2" rack unit and a fire extinguisher I 5914 5924 5934 5944 5954 Trimless I 16' 140' I 83/4" 18 1/4" 9' 2 1/2' lire department valve and a tire extinguisher I 'MEETS A.D.& PItOJECTION cnrrni E(P(3DED,1EW REFER TO DIMENSIONS TA& B F STEP 1 SELECT MODEL NUMBER AND QUANTITY (REFER TO CHART ON BACK FOR MODEL NUMBER). Determine Trim Style according to wall depth. Determine Tub I.D. according to size most suited for extinguisher and wait opening.. NOTE: If wall is fire rated, ask for separate Fire -FX'7" recessed or semi-recessed cabinet detail and submittal sheet. STEP 2 SELECT DOOR STYLE (CHECK ONE BOX BELOW) Cl V Contemporary V mporary V w/SAF-T-LOK IF 1Z S21 Solid-1 STEP 3 SELECT DOOR GLAZING (CHECK ONE BOX BELOW) H 1O\learAgr4s"" LI Gray Ac Ii 1_ T8sktjxe Glass D 17 mpered Glass ,,j-t5 Bronze Ar'$i Laminate lass STEP 4 SELECT OPTIONS (IF APPLICABLE CHECK ANY BOX BELOW) PZfF'— o Color Epoxy Tub - Red 0 FE Letters - 81k Vertical 0 Decals - 81k Vertis El Color Epoxy Tub - 81k 0 FE Letters - Red Vertical 0 Decals - Red Vertic O Aluminum Tub - Mill Finish 0 FE Letters - White Vertical 0 Decals - White Vert o Anodized Door - Bronze 0 FE Letters - Bilk Horizontal 0 Decals - Bilk l-Iorizc o Futura 'Fire' Handle 0 FE Letters - Red Horizontal 0 Decals - Red Horiz o Flush Pull Handle 0 FE Letters - White Horizontal D Decals - White Nor o Commander Alarm 0 Brigadier Alarm 0 .JL lNDLJBTlEB INJCORCRATE) 4450 W. 78th street Circle, Bloomington, MN 55436 Phone: 952-835-6850 FAX: 952-835-2218 e-mail: jl@jlindustries.com • web site: vw.jlindustries.com DISTRIBUTOR: QUANTITY: CONTRACTOR: APPROVED BY: MODEL NUMBER: 17 4 / ARCHITECT: PROJECT: ,*ç PL DATE: JL WEST COAST, 6285 RANDOLPH STREET, COMMERCE, CA 90040, PHONE: 323-726-9070, FAX: 323-726-9068 JL SOUTH EAST, 5758 CORPORATION CIRCLE, FT. MYERS, FL, PHONE: 239-693-7500, FAX: 239-693-7501 0 'A JL INDUSTRIES INCORPORATED FIREEXTINGUISHERS DETAIL A I .IijJ:] III f I I MODEL NUMBER: eosrwx. QUANTITY: 7' DISTRIBUTOR: 81. /4e.X e-i9soc'. PROJECT: 5,u- 6. ARCHITECT: CONTRACTOR: Ob APPROVED BY: DATE: GRENADIER: PRESSURIZED WATER GENERAL DATA: The water press" extinguisher contains water and compressed air. This unit is operated by simply squeezing the lever which opens the valve allowing the water to be forced out. It's especially effective on deep seated Class A fires. Units shipped empty. FEATURES: Butt-welded 304-L stainless steel cylinder (eliminates all internal and external crevices). Rugged stainless steel discharge lever chrome-plated valve body. Replaceable molded valve stem seal. U/L labeled chemical engine CLASS A FIRES - COSMIC: MULTI-PURPOSE CHEMICAL GENERAL DATA: These units contain specially fluidized and siliconized mono ammonium phosphate powder which smothers and breaks the chain reaction on Class B fires, fuses and insulates Class A fires, and is a non-conductor of electricity. Truly an all purpose extinguisher, the ABC Dry Chemical is the most popular unit currently on the market. FEATURES: Heavy duty steel cylinder. Rugged metal valve and siphon tube. Replaceable molded valve stem seal. Exclusive corrosion and impact resistant epoxy finish. Visual pressure gauge. Pull pin. Upright squeeze grip operation approved to -65°F (-52°C) Non-Toxic. CLASS A,B,C FIRES SENTINEL: CARBON DIOXV GENERAL DATA: This extinguisher contains liquid carbon dioxide under pressure which is'*lesedyTingt 1Vihe - discharge, which changes into a gas and appears as a smothering cloud of white snow, is then directed to the fire through a funnel shaped horn. The clean agent is particularly effective on small Class B fires and is a non -conductor of electricity. FEATURES: High pressure aluminum cylinder. Absolutely rust free and up to 30% lighter than CO2 units with steel cylinders. 0-Ring seal, straight thread brass valve fits all sizes. CLASS B,C FIRES GALAXY: REGULAR DRY CHEMICAL GENERAL DATA: These models contain a siliconized sodium bicarbonate base, the traditional dry chemical design. The Galaxy series ca n be an economical choice for Class B and Class C fire protection, due to generally lower recharging costs. Clean up after use is relative l y easy because the chemical does not normally bake to a hot metal surface FEATURES: Heavy duty steel cylinder. Rugged metal valve and siphon tube. Replaceable model valve stem seal. Exclusive corrosion and impact resistant epoxy finish. Visual pressure gauge. Pull pin. Upright squeeze grip operation on Approved to -65°F (-52°C) Non-Toxic. CLASS B,C FIRES MERCURY: HALOTRON 1 GENERAL DATA: JL introduces a new line of clean agent portable fire extinguishers which have the EPA approved, government accepted and specified clean extinguishing agent Halotron 1. This agent discharges as a liquid, then quickly evaporates leaving no residue to clean up afterwards. FEATURES: Drawn steel cylinders with steel siphon tubes. Power cone discharge stream. Corrosion resistant paint finish. Visual pressure gauge. Temperature range from -40F to +120F. CLASS A, B, C FIRES SATURN: WET CHEMICAL GENERAL DATA: These units make for the ideal choice for commercial restaurant applications. These extinguishers have been designed to offer the best possible portable fire protection available to supplement pre-engineered restaurant appliance fire suppression systems. A low "pH' potassium acetate solution is discharged in a fine mist that provides excellent range while it prevents splashing, creating an effective saponification foam type blanket necessary for suppressing liquid cooking media fires. FEATURES: Protective nozzle tip orifice seal. Industry standard discharge horn and nozzle design. Nameplate showing only the class "K" symbol. Non-metallic nozzle tip finger guard. Full stainless steel extinguisher shell construction. CLASS K FIRES r CLASS A FIRES - PAPER, WOOD, CLOTH, ' CLASS B FIRES. FLAMMABLE AISM CLASS C FiRES. LIVE ELECTRICAL CLASS K FIRES ETC., WHERE QUENCHING BY WATER OR LIQUIDS WHERE SMOTHERING EQUIPMENT WHERE THE NON.CONDUCTIV1TY CALL ii INDUSTRIES FOR INSULATING BY DRY CHEMICAL IS EFFECTIVE, - ACTION IS REQUIRED. OF EXTINGUISHANT IS VITAL. MORE INFORMATION JL INDUSTRIES FAX: 952-835-2218-4450 W. 78th St. Circle, Bloomington, MN 55435 PHONE: 952-835-6850 JL WEST COAST FAX: 323-726-9068 - 6285 Randolph Street, Commerce, CA 90040 PHONE: 323-726-9070 JL SOUTH EAST FA)(: 239-693-7501 - 5758 Corporation Circle, FT. Myers, FL 33905 PHONE: 239-693-7500 Visit our website for additional specification information. www.jlindustries.com MODEL # NOMINAL CAPACITY SHIPPING WEIGHT CYLINDER DIAMETER OVERALL HEIGHT OVERALL WIDTH SHIPPING VOLUME CU. FT. U/L RATING MARK BRACKET U.S.C.G.** APPROVED LI GRENADIER P 2 1/2 gal. 7 1/2 lbs. 7" 241/21, 9" 1.1 2A MB810 YES Demo-TiMr —&ir r111C —IC3'--- COSMIC SE 5 lbs. 9 1/4 lbs. 4 1/4" 15 1/4" 7 1/4" .3 2A-1013C MB818 YES ..hCQll— El COSMIC 6E 6 lbs. 4Jbe' 12 lbs. _a-3'4 5" _j5J.4 16" 7 3/4" j40BC MBj _E —. .. .4 5 -4OBC MB808 YES LI COSMIC 10E 10 lbs. 16 3/4 lbs. 5" 20 1/2" 7 3/4" .5 4A -6OBC MB846 YES LI COSMIC 20E 20 lbs. 39 lbs. 7" 24" 10 1/4" .9 20A -1 2013C MB810 YES LI SENTINEL 5 5 lbs. 14 lbs. 5 1/4" 17 3/4" 8 1/4" .6 513C MB862 YES LI SENTINEL 10 10 lbs. 281/4 lbs. 7" 24" 12" 1.2 1013C M1381 YES LI SENTINEL 15 15 lbs. 373/4 lbs. 7" 30" 12" 1.5 1013C MB864 YES LI SENTINEL 20 20 lbs. 503/4 lbs. 8" 30" 13" 1.8 1013C MB811 YES LI GALAXY 2 1/2 2 1/2 lbs. 5 1/2 lbs. 3" 14 3/4" 5 3/4" .2 1013C MB817* YES LI GALAXY 5 5 lbs. 9 lbs. 4 1/4" 15 1/4" 5 1/2" .3 1013C MB818* YES LI GALAXY 5 1/2 5 1/2 lbs. 9 1/2 lbs. 4 1/4" 15 1/4" 7 1/4" .4 4013C MB818 YES LI GALAXY 6 6 lbs. 13 lbs. 5" 16 1/4" 8 1/2" .4 4013C MB808 YES LI GALAXY 10 10 lbs. 18 lbs. 5" 20 1/2" 8 1/2" .5 6013C MB846 YES LI GALAXY 20 20 lbs. 381/2 lbs. 7" 24" 10 1/4" .9 120BC MBB10 YES LI MERCURY 21/2 2 1/2 lbs. 6 1/4 lbs. 3" 14 7/8" 6 1/8" .25 213C MB817 YES LI MERCURY 5 5 lbs. 10 lbs. 4 1/4" 15 1/4" 6 1/8" .3 SBC MB818 YES LI MERCURY 11 11 lbs. 23 lbs. 7 1/4" 20 1/2" 91/4" 1.0 1A-1013C MB822 YES LI MERCURY 15 1/2 15 1/2 lbs. 26 1/2 lbs. 7 1/4" 20 1/2" 9 1/4" 1.0 2A-10BC MB822 YES LI SATURN 15 6 liters 15 lbs. 7" 191/2" 14" 1.0 K MB810 - LI SATURN 25 2 1/2 gal. 19 lbs. 7" 25" 14" 1.1 K MB810 - FIRE EXTINGUISHER SIZES, CAPACITY, RATINGS IN IMPERIAL INDICATES MARK BRACKET STANDARD. J HOOK WALL BRACKET STANDARD WITH ALL OTHER EXTINGUISHERS. UNITED STATES COAST GUARD APPROVED. Note: J.L. extinguishers are shipped fully charged with the exception of the Grenadier P. and the Saturn 15 and 25. NFPA regulations also require extinguishers to be inspected when initially placed in service and all local tire code and tagging requirements rust be adhered to. ALL FIRE D<TIf'tGUISHER SIZES ARE NOMINAL. Look to JL Industries for Additional Products Including: • ACCeSS Panels • Roof Hatches • Floor Doors • Floor Mats and Gratings 9 Security Products • Life Safety - Automated External Defibrillators, Emergency Oxygen and Cabinets 4. FILE Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative (hereinafter defined as property owner). All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood that the property owner's authorized representative is a legal signatory and fully representative of the property owner and that by the property owner's or property owner's authorized representative's signature, the property owner accepts full responsibility for the system as installed and agrees that it is in compliance with the applicable approving authority's requirements and local ordinances. Property Name Date Property Address f /2sWe/0 5frfr.4 -, P go. Accepted by Approving Authorities (Names) 4/zA1S4o P/i D yMEW7, /4i9' CONS. Address I Plans Installation conforms to accepted Plans alyes El No Equipment used is approved I2Yes 0 No If no, explain deviations - Has the property owner or property owner's authorized representative been instructed as to the location of control valves and care and maintenance of this new equipment?' Yes El No If no, explain Have copies of the following been given to the property owner or property Instruction owner's authorized representative? System Components Instructions El Yes No Care and Maintenance Instructions 0 Yes ErNo NFPA25 JK Yes El No Location Of System Supplies Buildings Year Temperature Make Model of Manufacture Orifice Size Quantity Rating tP(b R3 Sprinklers prin ers s-s 3) Zooe Pipe and Type of Pipe O N4-T1Wt.b. / I>)?V4 A Fittings I Type of Fittings / .. Its: Maximum time to operate Alarm Valve Alarm Device through test connection or Flow Type Make Model Minutes Seconds Indicator Dry Valve Q.O.D. Make Model Serial No. Make Model Serial No. Time to trip Trip Point Time Water through test Water Air Air Rebe&Ti Alarm Operated Properly Dry Pipe connection* Pressure Pressure Press Outlet* Operating Mm/Sec psi si Mm/Sec Yes No Test w/oQ.O.D. with Q.O.D. If No *measured from time inspectors test opened (NFPA 13 only requires the 60-second limitation in specific sections) Operation LI Pneumatic LI Electric LI Hydraulic Piping Supervised LI Yes LI No I Detecting Media Supervise S LI No Does valve operate from the manual trip, remote, or both control stations? LI Yes LI No Is there an accessible facility in each circuit for testing? no, explain Deluge & Valves Does uiPreaction E-1 'operate No Doe each circuit operate valve Maximum time to operate Make Model pervision loss alarm? release? release Yes No Yes No Min Sec Location Make and Residual Pressure Pressure and Floor Model Setting Static Pressure (flowing) FInwRjte _________ ___________ Inlet (psi) Outlet (psi) Inlet (psi) Outlet (psi) Flow( pm) HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for two flours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar) for two hours. Differential dry-pipe valve clappers shall be left open during the test to prevent Test damage. All aboveground piping leakage shall be stopped. Description PNEUMATIC: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1 % psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1 1/z psi (0.1 bar) in 24 hours. All piping hydrostatically tested at 23psi ( bar) for .hours If no, state reason Dry prg r rtiiiy tfrl 0 Yes LI No Equipment operates properly JR Yes LI No Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing system or stopping leaks? X'yes 0 No Drain Reading of gauge located near water supply test connection Residual pressure with valve in test connection open wide Tests Test psi (bar) psi ( bar) Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping Verified by copy of the U Form No. 85B 0 Yes 0 No Other Explain ' Flushed by installer of underground sprinkler piping Yes 0 No If powder-driven fasteners are used in concrete, has 0 Yes No If no, explain representative sample testing been satisfactorily A//A completed? Blank Testing Number Used Locations Number Removed Gaskets Welded Piping YES LI NO If Yes... Do you certify as the sprinkler contractor that welding procedures comply with the Requirements of at least AWS B2.1? Yes LI No Do you certify that the welding was performed by welders qualified in compliance Welding With the requirements of at least AWS B2.1? Yes LI No Do you certify that welding was carried out in compliance with a documented quality Control procedure to insure that all discs are retrieved, that openings in piping are Smooth, that slag and other welding residue are removed, and that the internal Diameters of piping are not penetrated? 'Yes LI No Cutouts Do you certify that you have a control feature to ensure that all cutouts (discs) are (Discs) Retrieved? 5d Yes 0 No Hydraulic Nameplate provided 1K Yes LI No If no, explain Data Nameplate Remarks Date left in service with all control valves open /ii I08 Name of Sprinkler Contractor 4 Fts Tests Witnessed by: Signatures For property oviner (printed name) ) I, signature Title bate -N For sprinkler contractor (printed name) Signature Title Date ____________ Additional Explanation and Notes: 'TVA Kt : 1 ;i 4%'] DynamThread 0 Full Line Sch-40 Replacement Dyna-Threacf offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch40 is specified. Super 40fDyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. WI. Wt. (H20 Filled) Pcs/ Wt/Lift (21) Wtfl.ift (24') WI/lift (25') In; mm In; mm Lbs/Ft;Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg 1 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 11/4' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 11/2" 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 11• 16100 S. Lathrop Harvey, IL 60426 Customer Service: tqco/F/ow Control aIIiec:,J 11350 Norcom Rd. . Philadelphia, PA 19154 (800) 882-5543 TUBE& CONDUIT 2525 N. 27th Ave. - Phoenix, AZ 85009 Fax 708-339-1806 S3 -3 DYI%IA-FLOW® Dyna-Flow® High Strength Steel Pipe The original high-strength lightwall sprinkler pipe with hydraulics superior to Schedule-10. Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule- 10, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." j'YttT1i'iii. NPS Nominal I.D. Wt. WI. (H20 Filled) Pcs/ WI/Lift (21') WI/Lift (24') WI/Lift (25' In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 11/4" 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 lh/2 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 21/2' 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4" . 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. @ Uo - L <~> (~D Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. Additional Benef its Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. tLICO/Fiow Control 16100 S. Lathrop• Harvey, IL 60426 Customer Service: 'Y allied 11350 Norcom Rd. " Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27th Ave. Phoenix, AZ 85009 Fax 708-339-1806 S2-3 tqCD: Ffr & :& U. ing IProducts- Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series RFII - 56K-factor "Royal Flush II" Pendent Concealed Sprinklers Quick. & Standard Response, Standard Coverage General Description The Series RFII Quick Response (3 mm bulb) & Standard Response (5 mm bulb), 5.6 K-Factor, "Royal Flush II" Concealed Pendent Sprinklers are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. It is the best choice for archi- tecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprin- klers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of sus- pended ceiling panels for access to building service equipment without having to first shut down the fire pro- tection system and remove sprinklers. Also, the separable two-piece design of the the Sprinkler provides for 1/2 inch (12,7 mm) of vertical adjustment, to reduce the accuracy to which the length of fixed pipe drops to the sprin- klers must be cut. The Series RFII Sprinklers are shipped with a Disposable Protective IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Cap.-The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tectiveCap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling in- stallation is complete the Protective Cap is removed and the Cover Plate Assembly installed. As an option, the Series RFII Standard Response (5 mm bulb) "Royal Flush II" Concealed Pndent Sprinklers may be fitted with a silicone Air and Dust Seal (Ref. Fig. 5). The Air and Dust Seal is intended for sensitive areas where it is desirable to stop air and dust travel through the cover plate from the area above the ceiling. WARNINGS The Series RFIl Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the per- formance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY3551 (5 mm bulb) TY3531 (3 mm bulb) Technical Data Approvals for Series RFII UL and C-UL Listed. FM Approved. NYC under MEA 353-01-E. LPCB (Ref. No. 094a/09 for TY3551 & 094a/10 for TY3531) Approved. The approvals apply only to the serv- ice conditions indicated in the Design Criteria section. Approvals for Air & Dust Seal (Part #1 0908100) UL and C-UL Listed for use with the RFII (TY3551) Standard Response Concealed Sprinkler. Maximum Working Pressure: Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC. Maximum 175 psi (12,1 bar) by FM and LPCB. Temperature Ratings 155F/68C Sprinkler - 135F/57C Plate 200F/93C Sprinkler - 165F/74C Plate Discharge Coefficient K = 5.6 GPM/psi112 (80,6 LPM/barl'2) Adjustment 1/2 inch (12,7 mm) Finishes Cover Plate: Chrome Plated, Brass Plated, or White Painted (Custom paint matches and colors other than white are available on request.) Page 1 of 4 JANUARY, 2008 TFPISI Page 2 of 4 TFPI8I 1/2" NPT SEALING ASSEMBLY FRAME CAP SUPPORT 2 CUP WITH BULB ROLL FORMED THREADS I - COMPRESSION SCREW GUIDE PINS (2) I DEFLECTOR I I (DROPPED DEFLECTOR I I POSITION) I I II I I I SPRINKLER/SUPPORT CUP ASSEMBLY I THREAD INTO fi RETAINER SUPPORT CUP WITH THREAD UNTIL MOUNTING C) DIMPLES SURFACE IS FLUSH WITH EJECTION CEILING SPRING SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 SERIES RFII CONCEALED SPRINKLER ASSEMBLY Physical Characteristics Frame .............Bronze Support Cup . Chrome Plated Steel Guide Pins ......Stainless Steel Deflector ...........Bronze Compression Screw ......Brass Bulb ...............Glass Cap ........Bronze or Copper Sealing Assembly .......... Beryllium Nickel w/Teflon* Cover Plate ...........Brass Retainer ............Brass Ejection Spring . . . . Stainless Steel Patents U.S.A. 4,014,388 Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Retainer at three points, falls away to expose the Sprinkler As- sembly. At this point the Deflector sup- ported by the Guide Pins drops down to its operational position. The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. Design Criteria The RFII (TY3551), 5 mm Bulb Type, Concealed Pendent Sprinklers are UL and C-UL Listed as standard response - standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Approved as standard response - standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The RFII (TY3531) 3 mm Bulb Type, Concealed Pendent Sprinklers are UL and C-UL Listed as quick response - standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Approved as standard response - standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The Series RFII Concealed Pendent Sprinklers are only listed and ap- proved with the Series RFII Concealed Cover Plates having a metallic or white painted finish. The Series RFII must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sup- port Cup could delay sprinkler opera- tion in a fire situation. Installation The Series RFII must be installed in "accordance with the following instruc- tions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/68°C and 3/32 inch (2,4 mm) for the 200°F/93°C tem- perature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under- or over-tightening the Sprinkler/Support Cup Assembly. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the Centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 4. Wrench tighten the sprinkler using only the RFII Sprinkler Wrench (Ref. Figure 3). The RFII Sprinkler Wrench is to be applied to the Sprin- kler as shown in Figure 3. Step 5. Replace the Protective Cap (Ref. Figure 4) by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent damage to the Deflector and Arms dur- ing ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Protec- tive Cap. NOTE As long as the Protective Cap remains in place, the system is considered to be "Out of Service". Registered Trademark of DuPont H H -\____T T 3/16" to 11/16" MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32" (2,4 mm) POSITION •ASSEMBLY COVER PLATE COVER PLATE - PROFILE DEPTH - DIAMETER DIMENSION B DIMENSION A 3-1/4"(82,6 mm) C: 2-3/8" to 2-5/8" (60,3 to 66,7 mm) 3/16" (4,8 mm) D: 1-3/4" to 2-1/4"(44,5 to 57,2 mm) FIGURE 2 SERIES RFII CONCEALED SPRINKLER INSTALLATION DIMENSIONS TFPIBI Page 3 of 4 iI FRAME ARM SUPPORT CUP [L i 7/8"(23mm) SQUARE ALIGN ARROWS WITH FRAME ARMS ACCEPTS 1/2" SOCKET DRIVE FIGURE 3 RFII SPRINKLER WRENCH CLEARANCE HOLE FIGURE 4 DISPOSABLE PROTECTIVE CAP Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the outside edge of the seal is oriented according to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. NOTE The Air and Dust Seal is only to be installed on the periphery of the Re- tainer. Step 8. Screw on the Cover Plate/Re- tainer Assembly until the Retainer - Figure 2 (or Air and Dust Seal - Figure 5) contacts with the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Re- tainer Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The Series RFII must be maintained and serviced in accordance with the following instructions: NOTES Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING DIMENSION C SPRINKLER SUPPORT CUP ASSEMBLY 1/2" (12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING RETAINING RING MOUNTING SURFACE Page 4 of 4 TFPI8I SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING SEAL / BEVEL AS COVER SHOWN PLATE RETAINER ASSEMBLY JAINERPLAfr CLEAN ROOM LIP OF COVER SEAL RET FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper opera- tion of the sprinkler. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be re- placed, if necessary, by factory painted units. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. If a Cover Plate Assembly becomes dislodged during service, replace it im- mediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accord- ance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied. including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder Ordering Procedure When placing an order, indicate the full product name. Contact your local distributor for availability. Sprinkler Assembly: Specify: (SIN), (specify temperature rating) Series RFlI Concealed Pen- dent Sprinkler, P/N (specify). 155F/68C 200F/93C TV3551 51-790-1-155 51-790-1-200 TY3531 51-792-1-155 51-792-1-200 Separately Ordered Cover Plate: Specify: (specify temperature rating) Series RFll Concealed Cover Plate with (specify finish), P/N (specify). 135F/57C(a) 165F/74C(b) Brass 56-792-1-135 56-792-1-165 Bright Brass 56-792-2-135 56-792-2-165 Chrome 56-792-9-135 56-792-9-165 Brushed Chrome 56-792-8-135 56-792-8-165 White 56-792-0-135 56-792-0-165 White (RAL9010) 56-792-3-135 56-792-3-165 Bright White 56-792-4-135 56-7924-165 Off White 56-792-5-135 56-792-5-165 Black 56-792-6-135 56-792-6-165 Custom 56-792-X-135 56-792-X-165 For use with 155F/68C sprinklers. For use with 200F/93C sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench: Specify: RFlI Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal: Specify: Air and Dust Seal, P/N 56-908-1-001. © 2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tijLo I Ffre .&Bui PrQ.ducts Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series TY-FRB - 2,8; 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10(1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recess ed adjustthent or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to perate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction; Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I -. Upright 2.81K, 1/2"NPT TY1231 - Pendent 2.81K, 1/2"NPT TY2131 - Upright 4.21K, 1/2"NPT 1Y2231 - Pendent 4.21K, 1/2"NPT TY3131 -. Upright 5.6K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.01K, 314"NPT TY4231 - Pendent 8.0K, 3/4"NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.0K, 1/2"NPT Page 1 of 10 AUGUST, 2007 TFPI7I Page 2 of 10 ESCUTCHEON 7/16"(11,1 mm) PLATE SEATING NOMINAL SURFACE 1/2" MAKE-IN NPT 2-1/4" (57,2 mm) (III SJ"I STYLE 10 or 20 RECESSED ssu ESCUTCHEON DEFLECTOR (11"I mm) NOMINAL 7/16" MAKE-IN 2-3/16" WRENCH (55,6 mm) / FLATS 1/2" NPT SSP DEFLECTOR * I---- 2-7/8" (73,0 mm) DIA. TFPI7I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE T__ 2-3/16". (55,6 mm) 1-1/2" (38,1 mm) 7/16"(11,1 mm) STYLE 10 or 20 NOMINAL RECESSED 1/2 MAKE-IN ESCUTCHEON SSP DEFLECTOR * 2-7/8" (73,0 mm) 01k SSU * DEFLECTOR 7/16." I (11,1mm) 1 NOMINAL I MAKE-IN -1 MAX WRENCH - _____ ___ (55,6 mm) FLATS _ H 1/2"NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 2J16" 6mm) (55,6 mm) 1 (38, 7/16"(11,1 mm) NOMINAL MAKE-IN 1/2' NPT TFPI7I Page 3 of 10 STYLE 100r20 RECESSED SSU* ESCUTCHEON DEFLECTOR 7/16" (11,11 mm) 1 FFLATS NOMINAL E-IN H MAK2-3/16" (55,6 mm) 1/2 NPT I SSP DEFLECTOR * H 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector 2 - Button Assembly 5- Compression Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING NOMINAL SURFACE 3/4' MAKE-IN NPT 2-5/16" _ (58,7 mm) 1-9/16" (39,7111111) I STYLE 30 or 40 RECESSED SSU* ESCUTCHEON DEFLECTOR 6* 1/2" I 5 (12,7 mm) I NOMINAL I MAKE-IN I 2-1/4" S (57,2 mm) / 3 WRENCH FLATS SSP DEFLECTOR* 2-7/8"(73,0 mm) DIA. -"- 3/4" NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT 7/16"(11,1 mm) NOMINAL 1/2' MAKE-IN NPT 2-1/4 (57,2 mm) f I 1-9/16' WRENCH I (39,7 mm) FLATS DEFLECTOR PENDENT UPRIGHT CROSS SECTION SSu * DEFLECTOR Page 4 of 10 TFPI7I 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5- Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi1/2 (40,3 LPM/barl'2) K = 4.2 GPM/p5i1/2 (60,5 LPM/bar112) K = 5.6 GPM/psil/2 (80,6 LPM/barl/2) K = 8.0 GPM/psi1/2 (115,2 LPM/barl'2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. .4- TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE IPOLYESTER 2.8 1/2" PENDENT (TY1231) and UPRIGHT (TYII3I) 135"F/57°C Orange 123,5 155"F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286"F/141°C Blue NPT 135°F/57"C Orange 1, 2, 5 RECESSED PENDENT (TY1231)* Figure 6 155°F168°C Red 175°F/79"C Yellow 200°F/93°C Green 135°F/57°C Orange RECESSED (TY1231)** Figure 7 PENDENT 155"F/68°C Red 175"F/79°C Yellow 200°F/93°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F/57"C Orange 1,2 155°F/68"C Red 175°F/79"C Yellow 200°F193"C Green 286°F/141°C Blue RECESSED (TY2231)* Figure 8 135°F/57"C Orange PENDENT 155"F168°C Red 175°F/79°C Yellow 200"F/93"C Green 135°F/57°C Orange RECESSED PENDENT (TY2231)** Figure 9 155°F/68°C Red 175"Fi79°C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Page 5 of 10 Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL BRASS I CHROME PLATED ILIQUID POLYESTER WHITE LEAD COATED 5.6 1/2" PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1,2,3,45,6,7 1,2,3,5 155°F/68"C Red 175"F179"C Yellow 200°F193°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY3231)* Figure 10 135°F/57°C Orange 1, 2,4, 5 N/A 155°F/68"C Red 175°F/79°C Yellow 200"F/93"C Green RECESSED PENDENT (TY3231) Figure 11 135°F)57"C Orange 1,2, 3,4, 5 N/A 155"F/68"C Red 175°F179°C Yellow 200°F/93°c Green 8.0 3/4" PENDENT (TY4231) and UPRIGHT (TY4131) 135°F157°C Orange 1,2,3,4,5,6, 7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 200"F/93°C Green 286°F/141°C Blue NPT RECESSED PENDENT (TY4231)* Figure 12 135"F/57"C Green 1,2,4,5 N/A 155"F/68°C Orange 175"F/79"C Red 200°F/93°C Yellow RECESSED PENDENT (TY4231)** Figure 13 135"F/57"C Orange 1,2, 3,4, 5 N/A 155"F/68"C Red 175°F/79°C Yellow 200°F/93°C Green 8.0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135°F/57"C Orange 1,2, 4, 5,6 1,2,5 155°F/68"C Red 175°F/79"C Yellow 200°F/93°C Green 286°F1141°C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED I POLYESTER I COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (T'y'3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) RECESSED PENDENT NPT TY4231) N/A 80 PENDENT (TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (12.1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The .Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286"F/141"C temperature ratings. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insu ff1- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING f \ - MOUNTING SURFACE CLOSURE SERIES TY-FRB ' L I 1/8" (32mm) I t 1-5/16"(33,3 mm)1 1-1/16' (27,0 mm) 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. 1/2" (12,7 mm) 1/4"(6,4 mm) (57,2 mm) MOUNTING FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - (73,0 mm) I 2-1/4" DIA. 1/2"(12,7 mm) 114"(6,4 mm) 1 (57,2 mm) MOUNTING L(32mm) I f I 1-1/4"(31,8 mm) I 1"(25,4 mm) 1/2±1/8" (12,7±3,2 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE SERIES Page 8 of 10 TFPI 71 - 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) I FACE OF L_57'2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) SURFACE MOUNTING/ CLOSURE SERIES 1-5/16"133 3 mm) TY-FRB 13/16"(20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-718"DIA. 5/8±1/4" (73 ,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) _._ 2-1/4" DIA. 1/4" (6,4 mm) ( FACE OF ¼.\I MOUNTING (57, SPRINKLER PLATE FITTING 1/8" - (3,2 mm) 2 MOUNTING/ SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) TV-FRB 3/4(19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- a' TFPI7I Page 9 of 10 - 2-7/8" DIA. 5/8±1/4" (73,0 mm) I 3/4"(19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. I 1/4" (6,4)1 FACE OF (57 2 MOUNTING SPRINKLER PLATE FITTING 1/8" 1 MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4"(19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-718"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (15,9:L6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I MOUNTING SPRINKLE MOUNTING FACE OF (57,2 mm) _- PLATE FITTING ___________ (2mm) SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16"(20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT - 2-7/8" DIA. - 1/2±1/8" I (73.0 mm) 1/2"(12,7 mm) [ (12,7±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) I SPRINKLER PLATE- FACE OF mm) MOUNTING 1/8 I FITTING 1 (32mm) t \ MOUNTING 7 SURFACE SERIES 1-1/4"(31,8 mm) CLOSURE TYFRB 1"(25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2'(12,7 mm) I E (12,7±3,2 mm) 2-1/4" DIA. I 1/4"(6,4 mm) I FACE OF (57,2 mm) MOUNTING I SPRINKLER PLATE 1/8" II I (3.2 mm) I \ MOUNTING SURFACE CLOSURE SERIES 1-5/16"(33,3 mm TY-FRB 1-1/16"(27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT pleted, to verify the integrity of the Cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 Should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. Page 10 of 10 TFPI7I PIN 57-XXX-X-XXX L MODEL/SIN_ 330 2.8K UPRIGHT (1/2"NPT) TY1I31 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TV3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (1/2'NPT) TY4831* 361 8.0K PENDENT (1/2"NPT) TY4931* I I L 135 SPRINKLER 155 . 175 200 286 RATING 1 NATURAL BRASS 155°F/68°C 4 WHITE POLYESTER 175*F/79*C 3 WHITE (RAL9010)* 2000F/93*C 9 CHROME PLATED 286°F/141°C 7 LEAD COATED * Eastern Hemisphere sales only. TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBPs sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. of merchantability and fitness fora oar- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 PATENT PENDING- Riser Manifol d Assembly I SEE STYLE 747P PRESSURE RELIEF OPTION The Victaulic Style 747P Riser Manifold Assembly is a compact, easy to install device with a pressure relief, intended for use in zoned wet sprinkler systems. The Riser Manifold Assembly includes the Manifold Body,. a Flow Switch, a Pressure Gauge, and a Style 720P TestMaster IlTM Alarm Test Module with standard W orifice and optional '½2 orifice. The Style 747P Riser Manifold Assembly is available in sizes from 2— 6/50 - 150 mm with grooved ends for easy installation. Note the drain connection on the TestMaster II is threaded. The Riser Manifold Assembly is FM Approved and UL and ULC Listed for working pressures up to 175 psi/1206kPa. DIMENSIONS Pressure Gauge Flow Switch Manifold Pressure Relief Valve - /1 TestMaster II A JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date________________________________ www.victaulic.com vlcTAuUC IS REGISTERED TRADEMARK OF VICTAuLIC COMPANY. © 2006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. ,ctaulic REVB - - . 10,98 .1 Riser Manifold Assembly STYLE 747P PRESSURE RELIEF OPTION MATERIAL SPECIFICATIONS Manifold Body: Fabricated from carbon steel pipe conforming to ASTM A53 Grade B with integral Victaulic grooved ends. Finish, orange enamel. TestMaster II: Bronze construction complete with dual integral sight glasses and standard W test orifice. Single handle operation for test and drain functions. Refer to Victaulic publication 10.22 for additional details. Waterf low Detector: System Sensor Model WED vane type waterilow detector with sealed retard, visual switch activation, and mechanical delay adjustment. Cover includes tamper resistant security screws and tool. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. III 11111 IIIlIIIIIIIIIIDIIIIIlIlIIIlIII WCAS-6TYQER For complete contact information, visit www.victaulic.com 10.98 3611 REV B UPDATED 912006 ictaulic vlCTAuljC IS A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. © 2006 vicTAuLic COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. . 10.98 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10' (250mm) Voltages Available: 24VAC 12OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -400 to 150°F (400 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK- 1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-TN TRANSIENT PROTECTION: Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA126 1750070 .12A 85 76 8(200) 12VDC MBA 128 1750080 .12A 90 77 10(250) 12VDC MBAI2I0 1750060 .1 2A 92 78 6(150) 24VDC MBA246 1750100 .06A 87 77 8(200) 24VDC MBA248 1750110 .06A 91 79 10(250) 24VDC MBA2410 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024 .1 7A 91 78 8 (200) 24VAC PBA248 1808024 .17A 94 77 10 (250) 24VAC PBA2410 1810024 .17A 94 78 6(150) 120VAC PBA1206 1806120 .05A 92 83 8 (200) 120VAC PBA1208 1808120 .05A 99 84 10(250) 120VAC PBA12010 1810120 .05A 99 86 Notes: I. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-340 to 660C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MKT. #8850001 - REV V PAGE I OF 2 MFG. #5400776. 10106 (E)POTTER The Symbol of Protection BELLS PBA-AC & MBA-DC FIG. I BELLS (2 0) 8" IL (200) 6" O) H (IS 211/16" (68) DIMENSIONS INCHES (mm) FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONE THREADED 1/2" CONDUIT ENTRANCE 53/4 3 318" (146) " - (86) (127) -6 - - I i /8 (41) (86) 4 /4' 0WC7776-1 (108) DWC# 776-2 FIG. 3 WIRING (REAR VIEW) A.C. BELLS WHITE (IN) WHITE (OUT) FROM CONTROL PANEL OR C.ILAIK UT) PRECEDING BELL BLACK (IN) ______ CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING AC BELLS. TERMINATEEACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DSVGY 776.3 INSTALLATION The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling, Remove the gong, Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as -designated by the authority having jurisdiction). PRINTED IN USA MKT. 98850001 - REV V PAGE 2012 MFG. 115400776 - 10106 @P01TER OSYSU-1 9 -2 OUTSIDE SCREW AND YOKE VALVE I ur oyiiwui vi r1uwuu;r SUPERVISORY SWITCH OSYSU-1 Stock No. 10 10 106 OSYSU-2 Stock No. 1010206 GENERAL INFORMATION The OSYSU is used to monitor the open position of an OS & Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, containing two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS & Y valves ranging in size from 2" to 12" (50mm to 300mm). They will mount on some valves as small as 1/2" (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replacement or additional cover screws and hex keys are available. See ordering information on page 4. UL and CSFM Listed, FM Approved, NYMEA Accepted, CE Marked Dimensions: 6.19"L X 2.25"W X 5.88"H 15,7cm LX 5,7cm W X 14,6cm H Weight: 2 lbs. (0,9 kg.) Enclosure: Cover - Die-Cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU- I: One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: NEMA 4 and NEMA 6P Enclosure (IP67) when used with appropriate watertight conduit fittings. Indoor or Outdoor use (Not for use in hazardous locations. See bulletin no. 5400705 OSYS-U-EX for hazardous locations.) Temperature Range: -40°F to 140°F (-40°C to 60°C) Conduit Entrances: 2 knockouts for 1/2" conduit provided Service Use: Automatic Sprinkler N,FPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 OPTIONAL COVER TAMPER SWITCH A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information on page 4. TESTING The OSYSU and its associated protective monitoring system should be inspected and tested in accordance with applicable NFPAcodes and standards and/orthe authority havingj urisdiction (manufacturer recommends quarterly or more frequently). Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MKT. 48820004 - REV P PAGE I OF 4 12/01 (E)POTTER The Symbol of Protection OSYSU-19 -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. 1 SMALL VALVE INSTALLATION - 1/2" THRU 2 1/2" (12,5mm THRU 63,5mm) SIZES THESE SWITCHES MOUNT CONVENIENTLY TO MOST 2" TO 12" OS & Y VALVES. THEY WILL MOUNT ON SOME VALVES AS SMALL AS 1/2' (12,5MM). J-HOOKS MAY BE REQUIRED ON VALVES WITH LIMITED CLEARANCE. CLAMP BAR CARRIAGE BC SLOTTED MOUNTING HOLES MAY BE USED FOR FINE ADJUSTMENT OF SWITCH ON BRACKET BRACKET DWG. #979-3 SMALL VALVE INSTALLATION I. Remove and discard "C' washer and roller from the trip rod. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non-threaded portion of the valve stem. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the 1' (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 procedure. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. Mark the valve stem at the center of the trip rod. Remove the OSYSU. File a 1/8" (3,2mm) deep groove centered on the mark on the valve stem utilizing a 3/16' (4,8mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and Out of the groove as the valve is operated. Mount the OSYSU with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 1) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate when the trip rod moves out of the groove. Tighten the adjustment screws and all mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FtJLLYTO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT iN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. I8820004 - REV P PAGE. 2 OF 4 12/01 ® POTT ER 0SYSU-19 -2 OUTSIDE SCREW AND YOKE VALVE I he oylnuui ul ri uwuuuii SUPERVISORY SWITCH FIG. 2 LARGE VALVE INSTALLATION - 3" THRU 12" (76mm THRU 300mm) SIZES 3" THRU 12" (76mm THRU 300mm) VALVES RACKET USE CARRIAGE BOLTS. BOLTS MOUNT ON INSIDE OF YOKE, IF THERE CLAMP BAR IS SUFFICIENT CLEARANCE. CARRIAGE (2 REQUIRED) BOLTS SLOTTED MOUNTING HOLES. MAY BE USED ROLLER FOR FINE ADJUSTMENT GROOVE OF SWITCH ON BRACKET YOKE VALVE STEM TRIP ROD DWG. #979-4 - ' GLAND LARGE VALVE INSTALLATION With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non-threaded portion of the valve stem. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: if trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one I" (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 procedure. Mark the valve stem at the center of the trip rod. Remove the OSYSU. File a 118" (3,2mm) deep groove centered on the mark of the valve stem utilizing a 3/8" (9,5mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. Mount the OSYSU loosely with the trip rod centered in groove. Final adjustment is made by loosening 2 screws (see Fig. 2) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. Tighten the adjustment screws and mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 3 OF 4 12/01 (E)POTTER The Symbol of Protection OSYSU49 -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. 3 DIMENSIONS FIG. 4 PARTS MR 0 X. SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL -4v 1600 OWe, 1923-3 CAUTION: An uninsulated section ofa single conductor should not he looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. TYPICAL ELECTRICAL CONNECTIONS LOCAL CIRCUIT N.0. INDICATING TO POWER FOR COrN.C. DEVICE INDICATING DEVICE I TO SUPERViSORY CIRCUIT END OF OF CONTROL PANEL II LINE COM. N.C. f RESISTOR DWG. #979-1 Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION BREAKING EXCESSIVE ROD LENGTH FIG. 5 ORDERING INFORMATION MODEL DESCRIPTION STOCK NO. OSYSU-1 Outside Screw & Yoke-Supervisory Switch (Single switch) 1010106 OSYSU-2 Outside Screw & Yoke-Supervisory Switch (Double switch) 1010206 -- Cover Screw 5490344 -- Hex Key for Cover Screws and Installation Adjustments 5250062 -- Optional Cover Tamper Switch Kit 0090131 For pressure reducer type valve installation kits (if required) contact valve manufacturer. OPEN VALVE POSITION CLOSED VALVE POSITION COM. SW fit COM. N.D. M. SW 92 SW 92 1-9 DWG. #979-2 PRINTED IN USA MKT. 118820004 - REV P PAGE 4 OF 4 12/01 Component of State of California OSHPD Approved Seismin Restraints System Maximum Design Load 1" thru 4" pipe size - 2015 lbs. 6" size - 1265 lbs. Fig. 1000 - "Fast Clamp" Sway Brace Attachment c®ususTw Size Range - Pipe size to be braced: 1 thru 6" Schedule 10 thru 40 IPS.* Pipe size used for bracing: 1" and 11/4' Schedule 40 lPS. * Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 - 8 ft. lbs. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig.1000 is used in conjunction with a TOLCOTM Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features - Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a 4-way riser brace. Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions - sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation —The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attach- ment component, Fig. 980, 910 or 909 to form a complete brac- ing assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install - Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe to be braced. Tighten hex nuts until leaf spring is flat. It is rec- ommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spac- ing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note - Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. TOLCO" brand bracing components are desgined to be compatible ONLY with other TOLCO" brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO"' brand bracing components, in the instance that such TOLCO'" brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO" brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 I CUSTOMER SERVICE • 800.786.5266 www.folco.com Longitudinal Brace Fig. 4L Longitudinal "In-Line" Sway Brace Attachment C®IJS LISTED Size Range - 21/2 through 8" IPS. Material - Carbon Steel Function - For bracing pipe against sway and seismic disturbance. Approvals - Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL) 21/2" through 8°. Installation Instructions - The Fig. 4L is the 'braced pipe attachment component of a longitudinal sway brace assembly. It is intended to be combined with the 'bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install - Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish -Plain Note - Available in electro-galvanized and HDG finish. Order By - Figure number, pipe size and finish. TOLCO'° brand bracing components are designed to be compatible ONLY with other TOLCO" brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO'° brand bracing components, in the instance that such TOLCO' brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO°'° brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. Dimensions • Weights Bolt Max. Rec. Approx. Sizes A C D Size Load Lbs. WtJ100 21h 6/16 21/2 23/4 1/2 2015 253 3 7 23/4 31/16 1/2 2015 268 4 81h 3% 311/16 1/2 2015 348 5 9Y4 37/h 43A 1/2 2015 380 6 11½ 5 51/8 1/2 2015 640 8 131/4 611/i6 61/8 1/2 2015 728 -- - -------- 'I r 4-Way Riser Brace (Plan view) FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH: 951737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5268 www.tolco.com Comoonent of State of Fig. 909 - No-Thread Swivel Sway.. Brace Attachment C®USUSTED Size Range - 1' bracing pipe. For brace pipe sizes larger than 1 use TOLCO Fig. 980. Material - Carbon Steel, hardened cone point engaging screw Function - The structural component of a sway and seismic bracing system. Features -This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2002) Figure 9.3.5.9.1 indicates clear- ly that fastener table load values are based only on concentric loading. No threading of the bracing pipe is required. Open design allows for easy inspection of pipe engagement. Application Note -The Fig. 909 is used in conjunction with the TOLCO Fig. 1000, Fig. 1001, or Fig. 4 (A) pipe clamp, and joined together with bracing pipe. Sway brace assemblies are intended to be installed in accordance with NFPA 13 (or TOLCO State of California OSHPD Approved Seismic Restraint Manual) and the manufactur- er's installation instructions. The required type, number and size of fasteners used for the structure attachment fitting shall be in accor- dance with NFPA 13 and/or OSHPD. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions - The Fig. 909 is the structural or transi- tional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 4A, 46 or 4L to form a complete bracing assembly. NFPA 13 and/or OSHPD guide- lines should be followed. To Install - Place the Fig. 909 onto the bracing pipe. Tighten the set bolt until head bottoms out on surface. Attachment can pivot for adjustment to proper brace angle. Finish Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, pipe size and finish. Dimensions • Weights Max. Design. Max. Design Load Approx. Pipe Size A B H* Load Lbs. Lbs. w/Washer Wt./100 1 6 1% 17/32 2015 2765 91 - Available with hole sizes to accommodate up to 3/4 fastener. Consult Factory. TOLCO" brand bracing components are desgined to be compatible ONLY with other TOLCO' brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NIBCO does NOT warrant against the failure of TOLCO" brand bracing components, in the instance that such TOLCO" brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO" brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com : WOC I E RSTM 2' i k c Box Weight good 'Aaa Nut Driver 1/4" 8018957 4016 SWG 100 114 X 1 2 9.38 125 Use #143W Nut Dnver E' 993ü Sj/4 X2 1 forSk1ewindei and 1/2"RodSammys 3/8" 8020957 18 SWG 10 1/4 X 25 7.50 125 37 1, W20 JX2 - 8 3/8' 802225 26 SWG25-380 3/8X2-1L 25 1281 125' 25 SWG3O wu 25 1OiP 12' _ teel 3/8" 8050957 39 SWD 10 1/4-14 X 1 25 7.50 125 19 '40 -1 q~14 X1J2 1 Pa #8114910 3/8". 8052957 41 SWD20 1/4-14 X 2 25 813 125: •. 3LL'957 42 SV5Q 5/i618X11/4 ,± 85 15 3/3' 8054957 46 SWDR 1-1/2" 114-20 X 1-1 2 25 905 125 : 43 SWb'1 ' 1(4 20 X 1 5 12'! 38' 3056957 44 S3JD51 5/16-18 X 1-1/4 25 1031 125 , 057957 .45 SWT 15 12-24X1 %1 /2 25 181 - 15 --'-..--.- -.-- .........- . Approvals SR Part,# Item Model - -------------'--- Descriptions Qty ( -- c -- Concrete -. 1/4' •8062957 1900 swç 200 5116 1 1/2 25 -. 938 i J - SWC2 5/X11/2 9 12-5 - 0 Most Items Available in Stainless Steel. , 1 L Sammy SwveI HeadTM - , Screw Approvals Part 1/ Item # Model Descriptions Box Weight Qty. (per 125) Case' . .... , Qty \ 17° deflection from vertical US PatentNo 6443,680 Accommodates up to 8139957 4702 SH-GIST 20 114 x 2 25 9 33 125 \\. 3-1/2 x 12 pilch roof 1tj2? 1/4 x2 J/ 9 38 4Y)- Also available in stainless steel 8141957 4704 SH-GST3O 1!4x3 4795 30S ' 1/4x 3 25 1094 25 10 94 125 -2-- • . - Use #14 Nut Driver (black) - -' 8137957 4700 SH-DSTR 1 1/4-20 x 1 25 5 38 125 1JQi 25 938 1251. -. ,,"-,' ,------"-- - "-.- - A W TM Directly.. ' • PatentPending. . , - ,,J:vIIwl J'II.O . •:. - dedR0dOtt , - . Steel . Screw Box Weight Case via irom Approvak Part# tern # Model Descriptions Qty. (per 125) Qty DeG &PutH - :, -, . -• •••- . .. .. j1 IL 22-20 8150922 500 XP 20 Sammy 0Xp,ess 20 25 103 125 ItI 18-16 815-3922 503 31, T7 T3 S • •5 ----------• ...... '\ . S3rnn1yX-Pres Uninstallt:J 35 .. jt- - . . 8151910 501 XPIT Sammy X-Press It 1 1.02 - . . . S • - .. Installation Tool - S (Kit includes: Sleeve Bit Receiver Hex Wrench and 25164 Drill Bit) ---E4 S S - S . (D Ins -talled '25j641190`1 - 1 .- 2 1/2 THRU 8 INCH PIPE Fig. 200 - "Trimline" Adjustable Band Hanger C®U$ LISTED Size Range - 1/2 thru 8" pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2 thru 8) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2' thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4' thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200WON. Order By - Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 2% 400 11 3/4 3/8 8mm orlomm 31/8 21h 400 11 1 3/8 8mm or 10mm 3% 2% 400 12 11/4 3/8 8mm or 10mm 3Y4 2/8 400 13 11/2 3/8 8mm or 10mm 37/s 2/e 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21h 3/8 10mm 55/8 41A 600 27 3 3/8 10mm 57/e 4 600 29 31h 3/8 10mm 7% 51/4 600 34 4 3/8 10mm 73A 5 1000 35 5 1/2 12mm 91/b 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 I CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25 - Surge Restrainer Size Range - One size fits 3/4' thru 2" pipe. Material - Steel Function - Designed to be used in conjunction with TOLCOTM Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed gniy when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4' thru 2". Patent #5,344,108 C®US LISTED k . ! F/I /1 1/ 7, - OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 75 - Swivel Attachment Size Range - 3/8 Rod Attachment Material - Carbon Steel Function - There are three recommended applications for this product: May be used as a Branch Line Restraint for structural attachment to anchor bolt, beam clamp, etc. May be used in a pitched or sloped roof application, to meet requirements of NFPA 13 (2002) Sec 9.1.2.5. May be used as an upper attachment with short hanger rod to omit seismic bracing (per UBC97). Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support up to 4' pipe. Meets requirements of Uniform Building Code (UBC) 1997 Table 0, Section 3.B. Finish - Electro-Galvanized Order By - Figure number cL.u:.usrD May be used as a structural attachment component of a branch line restraint OFFICEIMANUFACTIJRING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5268 www.tolco.com