Loading...
HomeMy WebLinkAbout2653 GATEWAY RD; ; AS090088; PermitCity of Carlsbad Sprinkler Permit Permit No: AS090088 Job Address: 2653 GATEWAY RD Permit Type: SPRINK Parcel No: 2131911900 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 7/31/2009 Approved: 7/31/2009 Issued: 7/31/2009 Inspector: Project Title: TWIG HAIR LOUNGE T.I. FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: Fees ($) Add'l Fees ($) Total ($) Balance ($) 130 0 130 0 AS OO'OU Material Data Submittal Twig Hair Lounge 2653 Gateway Road, Suite 104 Carlsbad, CA 92008 Jul -30 09 10:49a AAR Fire Sprinklers 16194454052 p-S tqcal F/re & Building Products Technical Services: Tel: (800) 381-93121 Fax: (800) 791-5500 Series TY-FRB— 2.8, 4.2, 5,6, and 8,0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the 'INSTALLER WARNING' that provides cautions with respect to handling and instal- lation of sprinkler systems and corn- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a tire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tänt coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their tire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers• 1Y1131 - Upright 2.8K, 1/2"NPT TY1231 - Pendent 2.8K, 1/2"NPT Ff2131 - Upright 41K, 1/2"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.6K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT Ff4131 - Upright 8.01K, 3/4'NPT Ff4231 - Pendent 8.01K, 3/4"NPT TY4831- Upright 8.0K, 1/2"NPT TY4931- Pendent 8.0K, 1/2"NPT Page 1 of 10 AUGUST, 2007 TFPI7I I ESCUTCHEON I PLATE SEATING SURFACE 112 NPT I I (57,2 mm) 7116(11,1 mm) NOMINAL MAKE-IN Jul-30 09 10:50a AAA Fire Sprinklers 16194454052 p.7 Page 2 of 10 TFPI7I STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR (11 1,11 mm) I FRATS NOMINAL I 7/16 MAKE-IN H (55.6 mm) 2-3/16 1/2' NPT SSP DEFLECTOR * H— 2-7/8"(73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5-Compression 7-Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TVI13I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16' (11,1 mm) PLATE SEATING NOMINAL SURFACE MAKE-IN NPT 2-3/16' (55,6 mm) f 1-lIT (38,1 mm) W STYLE 10 or 20 RECESSED ESCUTCHEON NOMINAL 4 MAKE-IN 2-3116" WRENCH FLATS (55,6 mm) 3 SSP DEFLECTOR* h — 2-7/8"(73,0 mm) DIA PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3-Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT 2-7/8" (73,0 mm) DIA. 1/2" (12,7 mm) NOMINAL MAKE-IN 2-1/4" (57,2 mm) CROSS SECTION Jul •30 09 10:50a ARA Fire Sprinklers 16194454052 p.8 TFPI7I Page 3 of 10 1/2" NPT 7/16"(11,1 mm) NOMINAL MAKE-IN ESCUTCHEON PLATE SEATING SURFACE 7 2-3/16_ (55,6 mm) 1-1/2" (36.1 mm) SSP DEFLECTOR* STYLE 10 or 20 RECESSED s* ESCUTCHEON JR'1L'I. FLATS 3 112* NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4- Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5-Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT(TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) PLATE SEATING 3/4. NOMINAL SURFACE MAKE-IN F_ — 1 2-5/16" _JJ NPT (58,7 mm) W (39.7mm) 1-9/16 STYLE 30 0r40 RECESSED SSU* ESCUTCHEON DEFLECTOR WRENCH FLATS SSP DEFLECTOR* - 2-7/8" (73,0 mm) DIA. 3/4" NPT PENDENT RECESSED PENDENT UPRIGHT - Frame 3-Sealing 4- Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5-Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (Y4131) AND PENDENT (7Y4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Ju130 09 10:51a RAR Fire Sprinklers 16194454052 p.9 Page 4of 10 TFP171 7/16' (11,1 mm) 1/2" NOMINAL SSU' NPT MAKE-IN DEFLECTOR t'AlIENCHIt 6 2-3/16 5 (57,2 mm)1-9/16" 3 (39,7mm)FLATS SsP * DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5-Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (Y4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient 1< = 2.8 GPM/psi112 (40,3 LPM/barl'2) K = 4.2 GPM/psi112 (60,5 LPM/bar112) K = 5.6 GPM/psi112 (80,6 LPM/barl'2) K = 8.0 GPM/psi112 (115,2 LPM/bar12) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. Jul.30 09 10:51a AAA Fire Sprinklers 16194454052 p.lo Page 5 of 10 TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE IPOLYESTER 2.8 1/2' PENDENT (TY1231) and UPRIGHT (TYII3I) 135°F157*C Orange 123,5 155°F/68"C Red 175"F179°C Yellow 200"FI93°C Green 286"F1141°C Blue NPT RECESSED PENDENT crviair Figure 6 135"F/57"C Orange 1, 2, 5 155'F/68"C Red 175°F/79°C Yellow 200"F193"C Green 135F/57"C Orange RECESSED PENDENT (TY1231) Figure 7 155"F/68°C Red 175F/79°C Yellow 200"F/93°C Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (n'2131) 135°F/57°C Orange 1,2 155°F/68"C Red 175"F179"C Yellow 200"F/93C Green 286°F/141°C Blue 135'F/57"C Orange RECESSED PENDENT (TY2231)* Figure 8 155°F168°C Red 175"F/79C Yellow 200"F/93°C Green RECESSED PENDENT (TY2231)" Figure 9 135"F/57C Orange 155"F/68C Red 175F/79"C Yellow 200°F/93°C Green NOTES: 1Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (314" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Jul -30 09 10:51a AAA Fire Sprinklers 16194454052 p.11 Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE POLYESTER LEAD' COATED - 5.6 PENDENT (TY3231) and UPRIGHT (1'Y3131) 135°F/57'C Orange 1, 2, 3, 4, 5, 6, 7 Blue 1,2,3, 5 155°F168'C Red 175'F179°C Yellow 200'F193°C Green 286'F1141'C 1/2' NPT 135'F/57'C Orange ' 1,2,4.5 Green ' N/A RECESSED PENDENT (1V3231) Figure 10 155°F168°C Red 175°F179'C Yellow 200'F/93'C 135'F/57'C Orange 1, 2, 3,4, 5 Green N/A RECESSED PENDENT (rY3231)' Figure 11 155'F168'C Red 175°F/79'C Yellow 200'F193'C - 8.0 PENDENT (TY4231) and UPRIGHT (TY4131) 135'F/57'C I Orange 1,2, 3,4,5, 6,7 Blue 1,2.5 155'F/68°C Red 175°F/79°C Yellow 200'F/93°C Green 286'F/141'C 3/4, NPT RECESSED PENDENT (1Y4231)* Figure 12 135°171571C Green 1,2,4,5 Yellow N/A 155'F/68°C Orange 175'F179'C Red 20OFI93°C RECESSED PENDENT (TY4231)" Figure 13 135'F/57°C Orange 1,2.3,4. 5 Green N/A 155'F168°C Red 175'F179°C Yellow 200'1`193'C - 8.0 1/2' NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135'F157'C Orange 1,2,4,5, 6 Blue 1, 2, 5 155°F168'C Red 175'F/79'C Yellow 200°F/93'C Green 286°F/141°C NOTES: Listed by Underwriters Laboratones,'Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31.53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. Installed with Style 10 (1/2' NPT) or Style 40 (3/4' NPT) 3/4' Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2' NPT) or Style 30 (314' NPT) 1/2' Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Jul -30 09 10:52a RAR Fire Sprinklers 16194454052 p.12 TFPI7I Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME I WHITE LEAD BRASS PLATED IPOLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/20 RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/40 RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (YY3131) OR 1/2" 175 PSI (12.1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4,, RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (TY4931) 1/2' and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL): and, the Approval by the City of New York. TABLE C, MAX/MUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the '2860F/141°C temperature ratings. A leak tight 1/2 inch NPrsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak fight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40.7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Jul-30 09 10:52a AAA Fire Sprinklers 16194454052 p.13 Page 8 of 10 - 2-718'DIA. (73,0 mm) I (19,1 mm) (15,9±6,4 mm) 2-1/4 01k I ii (6,4 mm) FACE OF (57.2 mm) 7- MOUNTING PLATE' FITTING __ ___________ 118 SPRINKLER I MOUNTING CLOSURE SERIES 1-5/16' SURFACE ________________ TY-FRB 13116"(20,6 mm) FIGURE 6 SERIES TY.FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7)8' 01k - 5/6t1/4 ______________ (73.0 mm) 3/4' (19,1 mm) r (15,9±6,4 mm) 2-1/4- DIA. 1/4' (6.4 mm) I I SPRINKLER FITTING PLATE I _ 2 rnJ FACE OF mm MOUNTING MOUNTING I SURFACE CLOSURE SERIES 1-1/4'(31,8 mm) TYFRB 3/4"(19,1 mm) FIGURE SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI7I - 2.718' OLA. - (73,0mm) 1/2±1/8' 112"(12,7 mm) r (12.7±3,2 mm) 2-1/4' DIA. 114"(6,4 mm) I I FACE OF 17-57,2 mm) MOUNTING SPRINKLER PLATE I I FITTING 1/& (3,2 mm) MOUNTING / SURFACE//I (33.3 mm)l CLOSURE SERIES TY-FRB 1-1/16'(27.0 mm) FIGURE 7 SERIES TYFRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL. ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8' DIA. (73.0 mm) 1/2±1/8' I 112'(12,7 mm) r (12,7±3.2 mm) 2-1/4' DIA. 114"(6,4 mm) I FACE OF .2 MM) MOUNTING I SPRINKLER PLATE FrrTING 1(8' \ MOUNTING SURFACE SERIES 1-114"(31,8 mm) CLOSURE TYFRB 1"(25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and al/personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- Ju130 09 10:53a AAA Fire Sprinklers 16194454052 p.14 TFPI7I - 2-7/8" CIA. 5/8±1/4' (73,0 mm) - (191 mm) - (15.9±6,4 mm) 2-1/4' CIA. 1/4' (6,4 mm) FACE OF MOUNTING SPRINKLER PLATE 57.2 FITTING 1/8' MOUNTING SURFACE SERIES 1-1/4'L31,8 mm CLOSURE 'rY-FRB 3/4" (19.1 rnnl) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" CIA. 5/8±1/4" (73,0 mm) '•'""'l 314"(19.1 mm) (15,916,4 mm) 2.1/4" DIX J 1/4" (6,4 mm) FACE OF (57,2 MOUNTING SPRINKLER PLATE FITTING 1/8] MOUNTING SURFACE/ CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16"(20.6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 2-7/8'DIA. 112±118" (73,0 mm) 1/2" (12,7 mm) r (12.7±3.2 mm) 2-1/4' CIA. I 1/4!'(6,4 mm) FACE OF MM MOUNTING I SPRINKLER PLATE I I FITTING 57,2 /71 / i /= MOUNTING SURFACE CLOSURE /J I \ SERIES 1-1/4" (31,8 mm TY.FRB 1' (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8' CIA. 112±118' (73,0 mm) 117 (12,7 mm) [(12.7±3.2 mm) .,_. 2-1(4" CIA 1/4' (6,4 SPRINKLER PLATE I FITTING 1 m m) I - (3.2 , j , 1 FACE OF ;.2mml NTING MOUNTING I t \ MOUNTING _ SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) Ty-FRO 1-1/16"(27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT pleted, to verity the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END 'A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B' USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified - WRENCH RECESS PUSH WRENCH IN TO 'ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. Jul-30 09 10:53a AAA Fire Sprinklers 16194454052 P.15 Page 10 of 10 TFPI7I PIN 57-XXX-X-XXX I L MODEL/SIN 330 2.8K UPRIGHT (112"NPT) TY1131 331 2.8K PENDENT (112'NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3I4NPT) 1Y4131 391 8.0K PENDENT (3/4"NPT) TY4231 360 8.0K UPRIGHT (1/2"NPT) TY4831* 361 8.0K PENDENT (1/2'NPT) TY493 I I t 135 SPRINKLER 155 175 200 286 RATING 1 NATURAL BRASS 155'F/68C 4 WHITE POLYESTER 175F/79C 3 WHITE (RAL9O1O)' 200°F/93C 9 CHROME PLATED 286F/141'C 7 LEAD COATED Eastern Hemisphere sales only. TABLED PART NUMBER SELECTION SERIES TV-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation. corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBPs sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor). (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table D). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish. P/N (specify). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Jul-30 09 10:48a AAA Fire Sprinklers 16194454052 p.3 Dyna-Flow® High Strength Steel Pipe The original high-strength lightwall sprinkler pipe with hydraulics superior to Schedule-10. Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule- 10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule- 10, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job Cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." Specifications NPS Nominal 1.0. W. WI. (H20 Filled) Pal WtIl.ift (21') Wt,t.ilt (24') Wtjljlt (25') In; mm In; mm Lbsrn; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 11/4' 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 11% 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2.203 2.104 3.79 37 1.634 1,868 1,946 50 56.0 3.1 5,64 37 741 847 883 2W 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3.314 3.387 7.18 19 1,351 1,544 1,608 80 64.2 5.0 10.69 19 613 700 729 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 1616 19 809 925 963 Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and UN. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA- 13 and NFPA- 14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. 0 <~> 9 Listed Approved Listed Dyna-Flow/Super Flo is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Flo is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. Additional Benefits Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as easy roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. 16100 S. Lathrop• Harvey, IL 60426 Customer Service: tqco/F/owcor?tro/ allied 11350 Norcom Rd. • Philadelphia, PA 19154 (800)882-5543 TUBE & CONDUIT 2525 N. 27 th Ave. 'Phoenix, AZ 85009 Fax 708-339-1806 S2-3 Jul-30 09 10:49a AAA Fire Sprinklers 16194454052 P.4 c® US US1ID Fig. 25 - Surge Restrainer Size Range - One size fits 3/4 thru 2 pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed pn1y when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4 thru 2. Patent #5,344,108 OFFICE/MANUFACTURING FACIUTY • 375 SAMPSON AVE. • CORONA. CA 92870 • P1-I: 951.7375509 • FAX: 951.737.8030 CUSTOMER SERVICE • 8007855255 www.Wko.com IMPERIAL MAX REC. LOAD LBS. METRIC* PIPE ROD PIPE ROD 112 3/8 400 10 314 318 400 20 10 1 3/8 400 25 10 1 1/4 3/8 400 32 11) 11/2 3/8 400 40 10 2 318 400 5D 10 21/2 3/8 600 65 to 3 3/8 600 80 II) 31/2 3/8 600 10 4 3/8 1000 100 10 5 1/2 1250 125 12 6 1/2 1250 8 1250 200 12 Order Part #300m Note: 1/2 Ring Hanger not <FM> approved 1/2 and 3/4 inch pipe 5 thru 8 Inch pipe Jul-30 09 10:49a AAA Fire Sprinklers 16194454052 p.5 H P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER 1 thru 4 mcli pipe LISTED FOR STEELICPVC SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - c® 203-EX 2551 . Approval guide - Pipe Hangers OSHPD OPA-060 I See Website. CONFORMS WITH: Federal Specification WW-H-171 (Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION - Per NFPA13, 13R, I3D and CPVC manufacturers instructions. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - ' Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. pipe A 0 T , LOM 2.5250 '14 2.1392 2.M50 T i 112 72673 2.9110 _2_ 2.lO4C 3.2516 2112 3.492C 4-1159 + LI A 60268 5202 o 1.5768 1/08