Loading...
HomeMy WebLinkAbout2650 GATEWAY RD; ; FPC2018-0158; PermitPERMIT REPORT ((7city of Carlsbad Print Date: 10/23/2020 Permit No: FPC2018-0158 Job Address: 2650 GATEWAY RD, CARLSBAD, CA Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2132620600 Track #: Applied: 05/17/2018 Valuation: $1,414,456.98 Lot #: Issued: 08/09/2018 Occupancy Group: Project #: DEV12023 Finaled Close Out: 10/23/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: UPTOWN BRESSI RANCH Description: CVS: UPTOWN BRESSI BLDG B -FIRE ALARM Applicant: E-TECHSECURITY RICHARD EDWARDS P0 BOX 3000461 ESCONDIDO, CA 92030-0461 (760) 535-6255 FEE AMOUNT FIRE Expedited Plan Review Per Hour - Office Hours $132.00 FIRE New Alarm System $1,227.00 Total Fees: $1,359.0b Total Payments To Date: $1,359.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov A ES-200X Intelligent Addressable FACP with Communicator ffC,7_DtZ --C)1 59 DF-60957: B (2) FIreuTeALarms by Honeywell I aommem=1 General The ES-200X is the latest intelligent addressable Fire Alarm Control Panel (FACP) from Fire-Lite Alarms. The ES-200X comes with a pre-installed communicator and supports up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the ES-200X programs just like Fire-Lite's other addressable products, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-FL Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTMF). Features Listed to UL Standard 864, 10th edition Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator over AiarmNet Optional CELL-MOD or CELL-CAB-FL GSM Central Station Communicator over AlarmNet® Automated activation of the ECC-50/100 Emergency Command Center ECC-FFT Firefighter Telephone option Compatible with SWIFT® wireless devices Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address Four built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices Notification Appliance Circuit End of Line resistor matching Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Built-in Programmer Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1,000 event capacity Addressable sounder base compatibility Multi-criteria detector (smoke, heat, CO) with programmable response Control module delay timer Automatic detector sensitivity testing (NFPA 72 compliant) Automatic device type-code verification Point trouble identification Waterfiow selection per module point Alarm verification selection per detector point Maintenance alert warns when smoke detector dust accumula- tion is excessive One-person audible or silent walk test with walk-test log and printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP Supports LiteSpeedTM and CLIP protocols SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire Single addressable SLC loop which meets NFPA Class B and Class A requirements 198 addressable device capacity (99 addressable detectors and 99 modules) Compatible with Fire-Lite's addressable devices (refer to the SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NACS) Four independently programmable output circuits. Circuits can be configured for the following outputs: - Style V (Class B) - Style Z (Class A) Silence Inhibit and Autosilence timer options Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability Selectable strobe synchronization per NAC 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24 VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A OF-60957:B • 3/6/2018 - Page 1 of 4 PROGRAMMING AND SOFTWARE Autoprogramming (learn mode) reduces installation time Custom English labels (per point) may be manually entered or selected from an internal library file Two programmable Form-C relay outputs 99 software zones Continuous fire protection during online programming Program Check automatically catches common errors not linked to any zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.firelite.com. User interface LED INDICATORS Fire Alarm (red) CO Alarm (red) AC Power (green) Supervisory (yellow) Trouble (yellow) Ground fault (yellow) Battery fault (yellow) Disabled (yellow) Maintenance (yellow) Communication (yellow) Alarm Silenced (yellow) F1-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge Alarm Silence Drill (Manual Evacuate) Four (4) programmable function keys Reset (lamp test) PRODUCT LINE INFORMATION ES-200X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre-installed communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. (For ES-200XC, refer to DF-60958.) FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.firelite.com. CELL-CAB-FLICELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the ES-200X. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- 75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional BB-55F for mount- ing. BAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps. COMPATIBLE ANNUNCIATORS ANN-80: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. ANN-110: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DF- 6024 1.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-SIPG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. S0365: Addressable low-profile photoelectric smoke detector. Lite- Speed only. S0365-IV: Addressable low-profile photoelectric smoke detector. Ivory. LiteSpeed and CLIP mode. SD365T: Addressable low-profile photoelectric smoke detector with thermal sensor. LiteSpeed only. SD365T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. LiteSpeed and CLIP mode. SD365R: Remote test capable addressable photoelectric smoke detector for use with DNR(V duct detector housing. LiteSpeed only. SD365R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR( duct detector housing. Ivory. Lite- Speed and CLIP mode. H365: Low-profile 135°F fixed thermal sensor. LiteSpeed only. H365-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. H365R: Low-profile, intelligent, rate-of-rise thermal sensor. Lite- Speed only. H365R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. LiteSpeed and CLIP mode. H365HT: Low-profile intelligent 190°F/88°C fixed thermal sensor. LiteSpeed only. H365HT-IV: Low-profile intelligent 190°F/88°C fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. Legacy Devices CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(V duct detector housing. 5D355C0: Addressable, low-profile device that provides fire, heat, and carbon monoxide (CO) detection. H355: Fast-response, low-profile heat detector. Page 2 of 4— DF-60957:13 • 3/6/2018 H355R: Fast-response, low-profile heat detector with rate-of-rise option. H355HT: Fast-response, low-profile heat detector that activates at 1 90°F/88°C. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (B35OLP base included). B200SR: Addressable sounder base. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. D355PL: IrinovairFIex low-flow non-relay duct-detector housing; includes SD355R. DNR: InnovairFIex low-flow non-relay duct-detector housing. (Order SD355R1SD365R separately.) DNRW: InnovairFIex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order SD355R/S0365R separately.) Addressable Modules MMF-300: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style V/Z (Class BI A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-I2LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). ISO-6: Six-fault isolator module. Mount one or two modules in a BB- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a 66-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE: LiteSpeed Wireless Gateway W-5D355: LiteSpeed intelligent, wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-SD3551: intelligent wireless photo/heat detector. W-H355: LiteSpeed intelligent wireless fixed-temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W-CRF: LiteSpeed Intelligent wireless relay module. W-BG12LX: LiteSpeed Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with The ES-200X, see the following data sheets (document num- bers): SD365 Series (DF-6 1010), H365 Series (DF-61011), A0355 (OF- 52386), BG-I2LX (DF-52013). CMF-300-6 (DF-52365), CRF-300-6 (OF- 52374), CMF/CRF Series (DF-52 130), CP355 (OF-52383), H355 Series (DF-52385). 1300 (DF-52389). ISO-6 (DF-60485), MMF-300 Series.! MDF-300 (DF-52 121), MMF-300-10 (DF-52347), MMF-302-6 (DF- 52356), SD355/S0355T (DF-52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series defection devices such as the CP300/CP350, SD300(T)1S0350(T) and older modules such as the M300, M301, M302, C304. and BG- IOLX are not compatible with LiteSpeed polling. If The SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R47K and R-3.9K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. DF-60957:8 3/6/2018 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits .1 Addressable device capacity..................................................198 Programmable software zones.................................................99 Annunciators.............................................................................16 Electrical Specifications AC Power: 1201240 VAC, 50/60 Hz, 3.25 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, super- vised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (ES-200X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for four NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4.7k ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 kQ - 22 kQ ELR range. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges NFPA Standards The ES-200X complies with the following NFPA 72 Fire Alarm Sys- tems requirements: - LOCAL (Automatic, Manual, Waterfiow and Sprinkler Supervi- sory). - AUXILIARY (Automatic, Manual and Waterfiow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterfiow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterfiow). - CENTRAL STATION (Automatic, Manual and Waterfiow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) - IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). - CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic ES-200X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:0500 FDNY: COA#6261 NOTE: See OF-60958 for ULC-listed model. AlarmNet®, Fire-Lite® Alarms, SWIFT®, and System Sensor®) are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. ISO 9001 We cannot cover all specific applications or anticipate all requirements. ____________________ All specifications are subject to change without notice. d I I 1 .J E1111111*8111111C & MNIFACT1RJNC QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Country of Origin: USA www.firelite.com Page 4 of 4— DF-60957:13 • 3I6f2018 FlrellTe iarms by Honeywell IPidtTAnnouncement New Addressable Fire Alarm Control Panels March 2018 Fire-Lite Alarms is pleased to announce the availability of our next generation line of addressable fire alarm control panels (FACPs) designed to give fire safety professionals more options for designing small to medium-sized fire systems. The Fire-Lite Endurance Series offers two new addressable FACPs - the ES-50X and ES-200X - that provide support for 50 (ES-50X) or 198 (ES-200X) addressable devices and feature built-in dual path communications, programmable buttons and support for combined fire and CO addressable detection. The new Endurance Series panels offer more connectivity options while decreasing costs with built-in IF and POTS dual path communications (eliminating the need to purchase hardware separately) as well as the ability to add cellular communications for additional backup and reliability. Both panels also include four programmable buttons to perform routine tasks quickly and feature a USB port for easy programing and firmware updates. Additionally, the Endurance Series offers simplified SWIFT® wireless operations featuring a built-in wireless display driver and annunciator saving fire alarm installers time and money on wireless projects. SWIFT® wireless systems simplify installation and are ideal for difficult-to-wire applications such as historically protected structures, buildings with high ceilings or other complex structures that require costly wiring. Contact your preferred Honeywell authorized security equipment distributor for ordering and pricing information. ES-50X 50 POINT ADDRESSABLE FIRE ALARM CONTROL PANEL MS-9050UD ES-200X 198 POINT ADDRESSABLE FIRE ALARM CONTROL PANEL MS-9200UDLS ANN-100 80 CHARACTER LCD REMOTE ANNUNCIATOR NEW CELL-MOD CELLULAR COMMUNICATOR FOR ES-50X AND ES-200X NEW PWRMOD24 3 AMP NAC POWER MODULE XRM-24B Please visit firelite.com for additional information. We appreciate your business and continued support of Fire-Lite Alarms products. FIRE-UTE ALARMS I ONE FIRE-UTE PLACE, NORTHFORD CT 06472 1 203-484-7161 1 Fire-Lite Frc-2j -O( VECTOR SECURITY® FIRE SYSTEM SPEC BOOK CVS PHARMACY Store #10743 SWC Palomar Rd & El Fuerte St Carlsbad, CA 92010 SUBMITTAL PREPARED BY: VECTOR SECURITY, INC. 2500 MAITLAND CENTER PARKWAY, SUITE 105 MAITLAND, FL 327851 866-608-3286 U L Applicant ID No: 100600-262 I Service Center No: 0 I Expires: 31-MAR-2018 I CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: CUMBERLAND, RI Alarm Service Company: (100600-262) Service Center: (100600-262) CVS CAREMARK CVS CAREMARK 200 HIGHLAND CORPORATE DR 200 HIGHLAND CORPORATE DR CUMBERLAND RI 02864-1786 CUMBERLAND RI 02864-1786 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category S8843i UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services) Central Station ***THIS CERTIFICATE EXPIRES ON 31MAR2018*** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" DF-52422 • Al-40 MS.9200UDLS(E) Intelligent Addressable FACP with Built-In Communicator (a Fire LITffALS by Honeywell Adtriessat3I 1.'ll:7 The Fire'Lite MS-9200UDLS is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/ Transmitter) all on one circuit board. This compact, cost effec- tive, intelligent addressable control panel has an extensive list of powerful features. While the MS-9200UDLS may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode, it can also operate in LiteSpeedTM mode-- Fire-Lite's latest polling technol- ogy--for a quicker device response time. LiteSpeed's patented technology polls 10 devices at a time. This improvement allows a fully-loaded panel with up to 198 devices to report an inci- dent and activate the notification circuits in under 10 seconds. With Litespeed polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. (Consult the wire table on page 3 for specific installation instructions.) The MS-9200UDLS's quick-remove chassis protects the elec- tronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. Available accessories include LED, graphic and LCD annunci- ators, and reverse polarity/city box transmitter. The panel is programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming infotmation. NOTE: Unless otherwise specified, the term MS-9200U0LS is used in this document to refer to both the MS-9200UDLS and the MS-9200UDLS(E) FACP5 (Fire Alarm Control Panels). FEATURES On-board DACT. Four Class B or two Class A NAC circuits. - 6.0 amps total NAC power with optional XRM-24. Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Complies with UL 864 9th Edition requirements. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Up to 32 ACM Series (ACM-16AT or ACM-32 series) annunciators or LCD-80F remote annunciators via EIA-485. EIA-232 printer/PC interface (variable baud rate) on main circuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 m.). See wire table on page 3. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum or total 24VDC system power shared between all NAC circuits and auxiliary power outputs is 3.6 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces Installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. DF-52422 • 09/20/06 - Page 1 014 USER INTERFACE LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAINTENANCE/PRESIGNAL (yellow) DISABLED (yellow) BATTERY FAULT (yellow) GROUND FAULT (yellow) KEYPAD CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys ENTER ORDERING OPTIONS MS-9200UDLS(E): 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, Sin- gle printed circuit board mounted on chassis, and cabinet. 4XTMF Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. DP-9692: Optional dress panel for MS-9200UDLS. TR-CE: Trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional BB- 55F for mounting. BAT Series: Batteries, see data sheet DF-52397. XRM-24(E): Optional transformer. Increases system power to 6.0 amps. Use XRM-24E with MS-9200UDLS(E). PRT/PK-CABLE: Cable printer/personal computer interface cable. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. COMPA TIBLE ANNUNCIA TORS ACM-8RF: Relay module provides 8 Form-C 5.0 amp relays. ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applica- tions. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the MS-9200UDLS, see the following data sheets (document numbers) ACM-8RFACM-817 (DF-51555), ACS/ACMSeries (OF- 52378), LOM Series (DF-51384), LCD-80F (DF-52185). LITESPEED COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. 5D355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. AD355: Low-profile, intelligent, "Adapt' multi-sensor detector (133501-P base included). CLIP MODE ONLY BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D350PL: Photoelectric low-flow duct smoke detector. 035ORPL: Photoelectric low-flow duct smoke detector with relay option. MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact Initiating devices. Mounts in standard 4.0' (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appli- aces. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface module mounted Inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9200UDLS, see the following data sheets (document numbers): A0355 (DF-52386), BG-12LX (DF- 520 13), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/ CRF Series (DF-52130), CP355 (DF-52383), D350PUD35ORPL (DF-52398), H355 Series (OF-52385),1300 (DF-52389), MMF-300 SerieslMDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), SD355/SD355T (OF-52384). 2) Legacy 300 Series detection devices such as the AD355, CP300/CP350, 50300(T)/S0350(T) and older modules such as the M300, M301, M302, C304, and BG-IOLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult fec- Page 2 of 4 - DF-52422 • 09120106 tory for further information on previous 300 Series devices. WIRING REQUIREMENTS While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical inter- ference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. SLC Protocol Wire Requirements Distance in Feet (m) Wire Size Wire Type Twisted-pair, shielded 10,000 feet(3,048 m) 12 AWG (3.31 mm2) Belden 9583, Genesis 4410, Signal 98230, WPW D999 Twisted-pair, shielded 8,000 feet (2,438 m) 14 AWG (2.08 mm2) Belden 9581, Genesis 4408, Signal 98430, WPW D995 CLIP Twisted-pair, shielded 4,875 feet (1,486 m) 16 AWG Belden (1.31 mm2) 9575, Genesis 4406, & 4606, Signal 98630, WPW 0991 Twisted-pair, shielded 3,225 feet (983 m) 18 AWG (0.78 mm2) Belden 9574, Genesis 4402 & 4602, Signal 98300, WPW D975 Untwisted, unshielded wire, in or out of conduit 3,000 feet (914 m) 12— 18 AWG (3.31 mm2-0.821 mm2) SIC Protocol Wire Requirements Distance in Feet (m) Wire Size Wire Type Non-Plenum (FPLR): Twisted-pair, unshielded 10,000 feet (3048 m) 12 AWG (3.31 mm2) Genesis 4315, Belden 5020UL Plenum (FPLP): Genesis 4515, Belden 6020UL Non-Plenum (FPLR): Twisted-pair, unshielded 8,000 feet (2.438 m) 14 AWG (2.08 mm2) Genesis 4313. Belden 5120UL Plenum (FPLP): LiteSpeed Genesis 4513, Belden 6120UL Non-Plenum (FPLR): Twisted-pair, unshielded 4,875 feet (1,486 m) 16 AWG (1.31 mm2) Genesis 4311, Belden 5220UL Plenum (FPLP): Genesis 4511, Belden 6220UL Non-Plenum (FPLR). Twisted-pair, unshielded 3,225 feet (983 m) 18 AWG (0.821 mm2) Genesis 4306, Belden 5320UL Plenum (FPLP): Genesis 4506, Belden 6320UL MS-9200UDLS Wire Requirements OF-52422 • 09/20/06 - Page 3014 SYSTEM SPECIFICATIONS SYSTEM CAPACITY Intelligent Signalling Line Circuits .......................................1 Addressable device capacity .......................................... 198 Programmable software zones.........................................99 Annunciators ....................................................................32 ELECTRICAL SPECIFICATIONS AC Power: MS-9200UDLS: 120 VAC, 60 Hz, 3.0 amps. MS- 9200UDLSE: 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery: Two 12 V 18AH lead-acid batteries. Battery charger capacity: 7— 18 AH. MS-9200UDLS cabinet holds maximum of two 18 AH batteries. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style V (Class B) or one Style Z (Class A) for a total of four Style V (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to Fire•Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Power (24 VDC Nominal): Jumper selectable (JP4) for conversion to resettable power output. Up to 0.5 amps total DC current available from each output. Power-limited. Four-Wire Resettable Special Application Smoke Detector Power (24 VDC nominal): Up to 0.5 amps for powering four- wire smoke detectors. Power-limited. Refer to Fire•Lite Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 40 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAG 1 control. Supervised and power-limited. Telephone Interface: Requires dedicated business tele- phone number with a minimum of 7 volts DC. Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. CABINET SPECIFICATIONS Door: 19.26° (48.92 cm.) high x 16.82 (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00° (55.88 cm.) high x 19.65' (49.91 cm.) wide. SHIPPING SPECIFICATIONS Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5' (57.15 cm.) wide x 8.5" (21.59 cm.) deep. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 491C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 270C/60 - 80°F. NFPA STANDARDS The MS-9200UDLS complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - AUTO DETECTOR SELF TEST AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic MS- 9200UDLS control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:208 LlteSpecd1T' is a trademark; and FireLite® Alarms is a registered trademark of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. 02006 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. 9330333=1 We cannot cover all specific applications or anticipate all requirements. EVIRMN a KIIIINAM1111 All specifications are subject to change without notice. IUALITY sysraus Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.flrelite.com Page 4 of 4 - DF-52422 • 09/20/06 df-52417:c • B-90 ANN-80 FureuTe°Atarms 80-Character LCD by Honeywell Serial Annunciator I1 1. Annunciit1 The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point information including device type, zone, Independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. it includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time dur- ing system commissioning. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswltch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, Individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4" square electrical box. Semi-flush mount to single, double, or 4 square electrical box. Use ANN-SB80KlT for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on If an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight ANN-805 can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 49°C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875' (17.46 Cm.) wide x 1.375" (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:211 MEA: 442-06-E The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. di-52417:c • 05/22/09 - Page 1 at 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-BUS communications circuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-BUS accessory mod- ules, It is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (1. Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. Power wire distance limitation is set by 1.2 volt maximum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge IS Gauge 16 Gauge 14 Gauge 0.100 1.852 ft. 4.688 ft. 6,000 ft. *6.000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION ORDERING OPTIONS: The following figure illustrates the wiring between the FACP and ANN-80: Red 80 character LCD Annunciator. ANN-BUS devices. ANN-80-W: White, 80 character LCD Annunciator. = _ 781 432 ANN-BUS Device MS-9050UD ANN-BUS and power wiring are supervised and power-limited. 12345678 ANN-SBSOKIT•R: Red surface mount backbox with angled wedge. ANN-SB80K1T-W: White surface mount backbox with angled wedge. FACP Wiring to ANN-BUS Device FlreLlte® Alarms Is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized USB of this document Is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. Notim- 9331=11=1 We cannot cover all specific applications or anticipate all requirements. ThIlfElf & M11N& All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-52417:c • 05/22(09 df-52121:b• E-325 MM F.300(A) Series, MDF.300(A) 8 Fire uTeALarms Addressable Monitor Modules by Honeywell General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 is a standard-sized module (typically mounts to a 4' [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. MMF-301 is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5 (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind the device it monitors. MMF.302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (iDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeed1M is a communication protocol developed by Fire-Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF-300 Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each mod- ule is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Cir- cuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used to replace M300 modules in existing systems. MMF-300 APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, watertlow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style 0 (Class C21 ow 'E ,I V... J - MMF-300 (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style 0 circuit. MMF-300 OPERATION Each MMF-300 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (openlnormallshort) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-300 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Maximum operating current: 375 pA (LED flashing). Maximum IDC wiring resistance: 1.500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301 Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFt) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. df-52121:b. 11/13/08—Page 1 o14 1415 A DDRESS 0 1 I 13, I[i:: TENS ONES r oH iuj FI UC) .jIl li-j LU -411 }0 15 The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- ing. The MMF-301 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm devices. The MMF-301 can be used to replace M301 modules in exist- ing systems. MMF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301 OPERATION Each MMF-301 uses one of the available module addresses on an SLC loop. it responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). MMF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 pA. Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3' (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65' (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF.302 Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFi) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. it transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. MMF-302 APPLICATIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style 0 (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style 0 application. MMF-302 OPERATION Each MMF-302 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-302 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 491C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF.300 Dual Monitor Module The MDF-300 Dual Monitor Module is intended for use in intel- ligent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel-controlled LED. NOTE: The MDF-300 provides two Class B (Style B) IDC circuits ONLY. Class A (Style 0) 10C circuits are NOT supported in any application. MDF-300 SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Maximum operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 320 to 120°F (0° to 49°C). Humidity range: 10% 1093% (non-condensing). Page 2014— dl-52121:b. 11/13/08 Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 2.125° (5.398 cm) deep. MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address "26", then it will automatically assign itself to addresses "26' and "27". NOTE: "Ones" addresses on the MDF-300 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address, L1 CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125' (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S3705 ("A"suffix models) FM Approved CSFM: 7300-0075-185 MEA:72-01-E Product Line Information NOTE: "A" suffix indicates ULC Listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SM8500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51309. Architects'/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. di-52121:b • 11/13/08 - Page 3 of 4 Fire-Lite® and LiteSpeed® are registered trademarks of Honeywell International Inc. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up.to.date and accurate. dl We cannot cover all specific applications or anticipate all requirements. II(lNI I MNIIIW1lIINI All specifications are subject to change without notice. QUALITY SYSTEMS Made lntfteu.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. - www.flreiite.com Page 4014— dt-52121:b • 11/13/08 March 13, 2003 DF-52374 • E-930 FlrelfferALarms www.flrellte.com GENERAL Fire-Lite's CRF-300-6 six-relay control module provides an intelligent alarm system with six Form-C relays. The first module is addressed from 01 to 154 while the re- maining modules are automatically assigned to the next five higher addresses. Provisions are included for disabling a maximum of three unused modules. A single isolated set of dry relay contacts is provided for each module address, which is capable of being wired for either a normally-open or nor- mally-closed operation. The module allows the control panel to switch these contacts on command. No supervision is provided for the controlled circuit. Each CRF-300-6 module has panel-controlled green LED in- dicators. The panel can cause the LEDs to blink, latch on, or latch off. FEATURES Six addressable Form-C relay contacts. Removable 12 AWG (3.25 mm2) to 18 AWG (0.9 mm2) plug- in terminal blocks. Status indicators for each point. Unused addresses may be disabled. Rotary address switches. Mount one or two modules in a BB-X2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-2F cabinet (optional). Mounting hardware included. SPECIFICATIONS Standby current: 1.45 mA (SLC current draw with all ad- dresses used; if some addresses are disabled, the standby current decreases). Alarm current: 32 mA (assumes all six relays have been switched once and all six LEDs solid ON). Temperature range: 32°F to 120°F (0°C to 490C). Humidity: 10% to 85% noncondensing. Dimensions: 6.8 (172.72 mm) high x 5.8° (147.32 mm) wide x 1.0 (25.40 mm) deep. Shipping weight: 1.1 lb. (0.499 kg) including packaging. Wire gauge: 12 AWG (3.25 mm2) to 18 AWG (0.9 mm2). Maximum SLC wiring resistance: 40 or 50 ohms, panel dependent. Maximum iDC wiring resistance: 40 ohms. Relay current: 30 mA/relay pulse (15.6 ms pulse duration), pulse under panel control. Relay contact ratings: 30 VDC; 70.7 VAC. CRF-300-6 Six-Relay Control Module Section: Addressable Devices < > 0 California State Fire Marshal 7300-0075:205 LISTED APPROVED S3705 lvi EA 55-02-E Current ratings: 3.0 A @ 30 VDC maximum, resistive, non-coded. 2.0 A @ 30 VDC maximum, resistive, coded. 1.0 A @ 30 VDC maximum, inductive (L/R = 2 ms), coded. 0.5 A © 30 VDC maximum, inductive (L/R =5 ms), coded. 0.9 A © 110 VDC maximum, resistive, non-coded. 0.9 A © 125 VAC maximum, resistive, non-coded. 0.7 A © 70.7 VAC maximum, inductive (PF = 0.35), non- coded. 0.5 A @ 125 VAC maximum, inductive (PF = 0.35), non- coded. PRODUCT LINE INFORMATION C RF-300-6: Six-relay control module. I This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all IS09001 requirements. All specifications are subject to change without notice. For more information, contact Fire'Llte Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. I BdlrfUli I MANl1NC1URlN Page 2 of 2 - DF-52374 • 03/13103 1 I I I I 11 I 0 0 ADDRESS DISABLE NONE - ONE TWO THREE WIRING DIAGRAM FROM PANEL OR PREVIOUS DEVICE COMMUNICATION LINE, 32 VOC MAXIMUM. SEE PANEL MANUAL FOR WIRE REQUIREMENTS. TO NEXT DEVICE DF-52013:B e E-100 BG.1 2LX Addressable Manual Pull Station 0 FlreLITe°ALarms by Honeywell Addressablej .14t1 The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that Includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. Specifications a Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC loop current: 230 pA. Ambient Temperature: 32°F to 120°F (0°C to 49°C) Relative Humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F) For use indoors In a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SBA 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4' (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600, 1 - 99 and MS-9200UDLS, 1 —50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4 (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. DF-52013:8• 10/20/2008—Page lot 2 Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. SBA 0: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S711 MEA: 67-02-E CSFM: 7150-0075:184 FM Approved Detail of BREAKAWAY TAB 14 * 5) is 3R.5s 0 13 2 LOOP I Back of station without door Terminal Connections: I SLC (-); 2 SLC (+) sit 1tSW C, __ • Ld '! - I_I Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Patented: U.S. Patent No. 0428,351: 6,380,846; 6,314772; 6,632,108. ROTARY DECIMAL LED * Remove tab to select addresses above 99. FireLite is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. -. Iso 9001 We try to keep our product information up-to-date and accurate. _____________ - We cannot cover all specific applications or anticipate all requirements. NIMINI & MtlIfM11RING All specifications are subject to change without notice. SUALITY SYSTIMS Made In the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-5201 3:B • 10/20/2008 55 with _)LP base df-52384:A • E-160 SD355(A), SD355T(A) ArnihI D,iIoit*ria. 0 FlreuTe°Atarms - U U Smoke Detectors by Honeywell AddressableDevices f General The SD355(A) and SD355T(A) addressable, low-profile plug- in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire'Lite's Address- able Fire Alarm Control Panels (FACP5). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annun- ciator capability is available as an optional accessory (P/N RA400Z). Features SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry of address: 01 - 99 with MS-9200 and MS-9200UD and MS-9200UDLS, and 01 - 159 with MS. 9600, MS-9600LS, and MS-9600UDLS. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5° (8.89 cm) or 4.0 (10.16 cm) octagonal box, or 4.0' (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RE/transient pro- tection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA400Z). SD355T with B350LP base Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white LEXAN®. 5D355(T) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation S0355(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring. 4.0° (10.16 cm) octagonal box. 3.5 (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class B) wiring. df-52384:A • 12/19/08 - Page 1 of 2 Operation Each S0355(T) uses one of 99 possible addresses on the MS- 9200, MS-9200U0 and MS-9200UDLS and up to 318 (159 on each loop) on the MS-9200 series Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The S0355(T) addressable photoelectric sensor's unique uni- polar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) without sending an alarm level signal. Because of its unipolar chamber, the 5D355(T) is approximately two times more responsive than most photo- electric sensors. This makes it a more stable detector. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 7 on inspection, Testing and Maintenance) when installed/connected to a MS-9200, MS-9200UD, MS- 9200UDLS, or MS-9600, MS-9600LS and MS-9600UDLS addressable fire alarm control panel. The results of the sensi- tivity test can be printed off the MS-9200, MS-9200DLS, MS- 9200UD, MS-9600, MS-9600LS or MS-9600UDLS for record keeping. Specifications Voltage range: 15-32 VDC (peak). Standby current: 300 hA @ 24 VDC. LED current: 6.5 mA @ 24 VDC (latched ON'). Air velocity: 4,000 ft/mm. (20 m/sec.) maximum. Diameter: 6.1° (15.5 cm) installed in B350LP base. Height: 2.1' (5.33 cm) installed in B350LP base. Weight: 3.6 oz. (102 g). Operating temperature range: for SD355(A): 0°C to 49°C (32°F to 120°17); for SD355T(A): 0°C to 38°C (32°F to 100°F). Temperature: 0°C - 49°C (32°F - 1200F). Relative humidity: 10% - 93%, non-condensing. Listings Listings and approvals below apply to the SD355(A) and SD3551(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed, file S1059 ULC Listed, file S6963 CSFM approved: file 7272-0075:194 MEA approved: file 243-02-E FM approved Product Line Information NOTE: "A" suffix indicates ULC-Listed model. S0355: Adressable photoelectric detector; B350LP base included. SD355A: Sames as SD355 with ULC Listing (B350LPA base included). SD355T: Same as SD355 but with thermal element; B350LP base included. SD355TA: Same as 5D355T with ULC Listing (B350LPA base included). B35OLP(A): Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 35" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5' (3.81 cm). B224RB(A): Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0' (10.16 cm) octagonal box, or 3.5" (8,89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224Bl(A): Plug-in System Sensor Isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). Diameter: 6.2° (15.75 cm). Mounting: 4.0' (10.16 cm) square box with or without plaster ring, 4.0° (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5' (3.81 cm). B501BH-2(A): Plug-in System Sensor sounder detector base. Diameter: 6.0 (15.24 cm). Mounting: 4.0' (10.16 cm) square box with or without plaster ring. Mounting box has a minimum depth of 1.5° (3.81 cm). B501 BHT-2(A): Plug-in System Sensor temporal tone sounder detector base. ACCESSORIES: RA400Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and 8350LP(A) bases only. SMK400: Surface mounting kit provides for entry of surface wiring conduit. For use with 8501(A) base only. RMK400: Recessed mounting kit. For use with 8501(A) base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. Fire-Lite® Alarms Is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. 52008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. This document is not intended to be used for installation purposes. is0 00i We try to keep our product information up-to-date and accurate. 933CIZE= We cannot cover all specific applications or anticipate all requirements. l?&ld & MNMKFMMC All specifications are subject to change without notice. SUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473 FAX: (877) 699-4105. www.firelile.com Page 2 of 2- dt-52384:A • 12/19/08 E Th SYSTEM SENSOR Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert Advance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and I 1 feld-selectable candela settings for wall and ceiling strobes and horn/strobes. When installing Advance products, first attach a universal mounting plate to a four-inch square, four-inch octagon or double-gang junction box. The two-wire mounting plate attaches to a single-gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SoectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Features Electrically compatible with existing SpectrAlert products Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Plug-in design Field selectable candela settings on wall and ceiling units: 15,15/75, 30, 75, 95, 110,115,135,150,177,185 Same mounting plate for wall- and ceiling-mount units Shorting spring on mounting plate for continuity check before installation 'Tamper resistant construction Outdoor wall and ceiling products rated from -40°F to 15 1°F Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products rainproof per UL 50 (NEMA 3R) Compatible with MDL sync module Agency Listings SIC WAUNG <:M> I'd1EA ) 25.I653186 07d70' ,,obe0 ; 3 125' 73W'I653:18? (-Id— ,uoi,e.) 7125.I53188 ho,wslrobel. USTEO APPROVED approved chi,,,,/15o0e5) 7135.1653 1B9 0,0,0). chio'e) S401 I 3023572 MEMSS05 S5512 03593 SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box or double-gang back box, Two-wife products shall also mount to a single-gang 2 x 4 x 17/a-inch back box.A irnversal morrm.ng plate chat he used for morinring ceiling and wall products. The no::fication appliance circuit wiring shall terminate at the universal mounting plate. Also. SpectrAlert Advance products, when used w.th the Sync-Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 120(24 volts.When used with the Sync-Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 175 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply Strobes and born/strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135 150, 177, 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service The strobe shall Ce wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at li-IL over tire strobe's entire operadnrg voliace range Ihe strobe light shall consist ol a xellon flash tube arid assoiated lens/relleclor syslerrr Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective scrv:ce. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing alt Hz over the strobe's entire operating voltage range The strobe light shall consist of a xenon flash tube and associated lens/reflector system The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern.These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries, Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective serviceThe module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires.Thp module shall mount to a 4/6 x 41 A6 x 7¼-inch back box, The module snail also control two Style? (class B) circuits or one Style 7 (class A) circuit The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature -40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing Ondoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 120C1FWR or regulated 24DC/FWRi Operating Voltage Range' 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12to18AWG Ceiling mount dimensions (including lens) 6.8 diametei x 25 high (173 rnrn diameter x 64 mm high) Wall mount dimensions (including lens) 5,61 x 1,7W x 2 SD (112 mm Lx 119 mm W x 64 mm D) Horn dimensions 5F1 x 4.7W x t3D (147 mm I x 119 mm W x 43 mm Dl Wall-mount back box skirt dimensions (BBS-2, BBSW-2) 591 x 5.0W x 2.2 D (I S1 mmlx 128 mm W x S6 mm Dl Ceiling-mount back box skirt dimensions (BBSC-2, BBScW-2) 7 I diameter x 2.25- high (I SC mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions (SA-WBB) 5.71 x 5,1 'W x 2.0 D (145 mm Lx 130 mm W x 51 mm 0) Ceiling-mount weatherproof back box dimensions (SA-WBBC) 7.1 diameter x 2.0 high (180 mm diameter x SI mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395003 UL Current Draw Data iii rr .'i. .imi ,rImv1;wt.1 iii uI11TrmI 'imtiiita 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75° 142 148 77 81 Temporal Medium 44 49 58 69 30° NA NA 94 96 Temporal (.0w 38 44 44 48 75° NA NA 158 153 Non-temporal High 57 56 69 75 95° NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 L Max. Current -UL Draw (mA RMS), 2-wire Horn/Strobe, Standard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DClnput 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 - 194 201 Non-temporal 1-ugh 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-wire Horn/Strobe, High -Candela Range (1135-118S cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For 1< series products used at low temperatures, listed candela _Horn _and _____________ Output ___________________________________________________ ratings must be reduced in accordance with this table. 24 Volt Nominal 8-17.5 16-33 Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-temooral High 82 82 88 88 93 92 100 100 S Non-temporal Medium 78 78 85 85 90 90 98 98 6 Non-temporal Low 75 75 81 81 88 84 96 92 71 Coded High 82 82 88 88 93 92 101 101 8' Coded Medium 78 78 85 85 90 90 97 98 91 Coded Low 75 75 81 81 88 85 96 92 tSeings 7,8, and 9 are not available on 2-wire horn/strobe. AOS-O3953 ________ 0~~Switch Listed Candela Candela rating at -401F IS 15/75 Do not use below 32°F 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Rechargeable Sealed Lead-Acid Battery PS-1 2180 12 Volt 18.0 Amp. Hrs. Features: Absorbent Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any position. Power/volume ratio yielding unrivaled energy density. Rugged plastic case and cover Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. U.L. recognized under file number MH 20845. 0% PERFORMANCE SPECIFICATIONS NominalVoltage ................................................................................................................................................................12 volts (6 cells in series) Nominal Capacity 20 hour rate (900mA to 10.50 volts) .....................................................................................................................................................18.0 A.H. 10 hour rate (1.7Ato 10.50 volts)..........................................................................................................................................................17.OA.H. 5 hour rate (3.2A to 10.20 volts) .......................................................................................................................................................... 16.OA.H. 1 hour rate (11.1Ato 9.00 volts) ......................................................................................................................................................... 11.1 A.H. 15 min rate (34.3A to 9.00 volts)...........................................................................................................................................................8.6A.H. ApproximateWeight...............................................................................................................................................................12.6 pounds (5.73 kg) Energy Density (20 hour rate) .......................................................................................................1.53 Watt-hours/cubic inch (93.51 tt-hours/1) Specific Energy (20 hour rate)........................................................................................................17.14 Watt-hours/pound (37.71 Watt-hours/kg) Internal Resistance (Fully Charged Battery)..............................................................................................................12 milliohms (approximately) MaximumDischarge Current (< 7 Mm.) ............................................................................................................................................... 54 amperes Maximum Short-Duration Discharge Current (<10 Sec.) ................................................................................................................. 180 amperes Terminal configuration NB ....................................................................................................................Tin plated brass post with 5mm nut & bolt connectors F2 ...............................................................................Quick disconnect tabs, 0.250' x 0.032', mate with AMP. INC. FASTON "250" Shelf Life - ¼ of nominal capacity at 68° F (20° C) 1 Month .................................................................................................................................................................................................97% 3 Months .................................................................................................................................................................................................91% 6 Months .................................................................................................................................................................................................83% Operating Temperature Range Charge...........................................................................................................................................................-4°F (-20°C) to 1220F (500C) Discharge ...........................................................................................................................................................-4°F (-200C) to 140°F (60°C) Case ......................................................................................................................................................................................ABS Plastic To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. to 60 C.) 40 8) LU 0 - ioo I AmbIent Temperature 20C (6FF) 80 II1T1T!! Float Charging Voltage 2.25 -2.30 V/Cell II HHIII 120 a IOC 80 U I Co SC C., C .9 40 C 15 0 0 200 400 600 800 1000 1200 Number of Cycles - \ Diacharge Discharge Depth 100% Depth 60 Depth Discharge 20 _____________ -2. Charge Current: 0.IC 3 Ambient Temperature: 20°C to 25°C (68°F to 77°F) 1. Discharge Current 0.2C (Final Voltage 1.7V/Cell) I . I I I I 14.0 13.0 I mm. _X bra. Discharge Time Discharge Time vs. Discharge Current __Ull E W WIN Z 0 E INNEWEE IN_III I.._.i 0.90 1.8 3.6 9.0 18 36 Discharge Current (A) Physical Dimensions: in. (mm) Terminals I - dft 539 1371 -----...l 7 13(181) Tolerances are .1- 0.04 In. (*l- from) and .1- 0.08 in. (.1- 2mm) for height dimensions. All data subject to change without notice, (104°F) (68°F) (32°F) 20 15 10 5 5 TECHNICAL DATA: PS-12180 Shelf L(e & Storage Discharge Characteristics . Charging- 13% of capacity - -necessayu,Iess isreqlAaed. te 80 Charging before - - - - - - - - use is necessary o (41"F) toherecover 60 - \ .,JfuIIcapacity 8) I Charge may raiI - - - - - - - - - orestore&il 40C 30°C 20°C 1 Do not v u 40 - - (104°F) _(86°capacity. F) - - (66°F)-1--- bat1esread, I I I J_thiss, . :1___ - 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) Life Characteristics in Stand-By Use 0 1 2 3 4 Years Life Characteristics in Cyclic Use CHARGING Cycle Applications: Limit initial current to 5.4A. Charge until battery voltage (under charge) reaches 14.40 to 14.70 volts at 680F (200C). Hold at 14.40 to 14.70 volts until current drops to approximately 180mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to "float" voltage. "Float" or "Stand-By" Service: Hold battery across constant voltage source of 13.50 to 13.80 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. NOTE: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged after 6-9 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. - CORPORATE OFFICE CUSTOMER SERVICE 7550 Panasonic Way Tel: +1-619-661-2030 San Diego, CA 92154 USA Fax: +1-619-661-3648 Tel: +1-619-661-2020 customer-service@power-sonic.com Fax: +1-619-661-3650 national-sales@power-sonlc.com SALES I INTERNATIONAL Tel: +1.650-354-5001 Fax: +1-650-366-3662 batterypower-sonic.com www.power-sonlc.cOm PRINTED IN Ii S,A, 0107 IM r I ULJ zfl n YX The scope of this article covers the installation of wiring and equipment of fire alarm systems including all circuits controlled and powered by the fire alarm system including fire detection and alarm notification, guard's tour, sprinkler waterflow, and sprinkler supervisory systems; circuits controlled and powered by the fire alarm system include circuits for the control of building systems safety functions, elevator capture, elevator shutdown, door release, smoke doors and damper control, fire doors and damper control and fan shutdown, but only where these circuits are powered by and controlled by the fire alarm system. Fire Power Limited Cable: Type FPL, FPLR, FPLP NEC DEFINITIONS FOR ARTICLE 760 Fire Alarm Circuit: The portion of the wiring system between the load side of the overcurrent device or the power-limited supply and the connected equipment of all circuits powered and controlled by the fire alarm system. Fire alarm circuits are classified as either nonpower limited or power limited. Non-Power-Limited: A tire alarm circuit powered by a source that complies with NEC Sections 760-21 and 760-23. Power-Limited (PLFA): A fire alarm circuit powered by a source that complies with NEC Section 760-41. 19 Jacketed Unshielded L1.5 Applications: Fire Protective Signaling Circuits installed in the City of New York. Code Restrictions: Meets the requirements of New York City Local Law 5, and New York State Toxicity. - Features: Available in 500 Ft. or 1000 Ft. Spools. Sequential Footage Markings. Construction: Copper Conductors, Ruoropolymer Insulation and Jacket. - 1 Standard Jacket Color: Red. Color Code Chart 4. JACKETED UNSHIELDED U.S 150'C NOM. NOM. CAR AVG. WE AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART# 18 1 SQL, .198 45 UL, FPLP, NYC LL5 26 (LBS.) 5500 18 2 SOL. .312 45 UL, FPLP. NYC LL5 47 (LBS.) 5501 16 1 SQL. .214 55 UL, FPLP, NYC LL5 36 (LBS.) 5502 16 2 SOL. .345 55 UL, FPLP, NYC LL5 62 (LBS.) 5503 14 1 SQL. .244 60 UL, FPLP NYC LL5 47 (LBS.)5504 14 2. SQL, .374 60 UL, FPLP, NYC 1-1-5 87 (LBS)5506 12 1 SQL. .272, 65 UL, FPLP, NYC 1-1-5 67 (LBS-) 5505 Jacketed Shielded LL5 (Overall Shield) Applications: Fire Protective Signaling Circuits installed in the City of New York. Code Restrictions: Meets the requirements of New York City Local Law 5, and New York State Toxicity. Features: Available in 500 Ft. or 1000 Ft. Spools. Sequential Footage Markings. Construction: Copper Conductors, Fluoropolymer Insulation, Aluminum/Mylar Shield and Fluoropolymer Jacket. Standard Jacket Color: Red. Color Code Chart 4. JACKETED SHIELDED LL5 (OVERALL SHIELD) 1500 C AWG #ICOND. SOL NOM. O.D. NOM. CAP. PF/FT LISTINGS AVG. WT. PER Mfl PART# 18 1 SOL. .202 80 UL, FPLP, NYC LL5 28 (LBS.) 5550 18 2 SOL. .316 80 UL, FPLP, NYC LL5 51 (LBS.) 5551 16 1 SQL. .215 100 UL, FPLP, NYC LL5 42 (LBS.) 5552 16 2 SQL. .343 100 UL, FPLP, NYC LL5 71 (LBS.) 5553 14 1 SQL. .243 110 UL, FPLP, NYC 1-1-5 51 (LBS.) 5554 14 2 SOL. .398 110 UL, FPLP, NYC LL5 93 (LBS.) 5555 12 1 SOL. .276 130 UL, FPLP, NYC LL5 75 (LBS.) 5556 28 Genesis Series Cable toll free 800.222.0060 phone 262.947.0720 fax 262.947.0724 Fire Alarm Jacketed Unshielded Applications: Wiring of Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Risers and Plenums. Feature: Available in 500 Ft. or 1000 Ft. Tangle-Free Boxes, or Spools. Sequential Footage Markings. Construction: Copper Conductors, Polypropylene Insulation, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red or White. Conductor Color Code Chart 4. FIRE ALARM JACKETED UNSHIELDED 75' C AWG #/COND. SOL NOM. O.D. NOM. CAP PF/FT LISTINGS AVG. WE PER MFT PART# 22 4 SQL. .122 15 UL, FPL 15 (LBS.), 4101 22 6 SQL. .144 15 UL, FPL 19 (LBS.) 4102 22 8 SQL. .156 15 UL, FPL 24 (LBS.) 4103 22 10 SQL. .182 15 UL, FPL 31 (LBS.) 4104 22 12 SQL. ,188 15 UL, FPL 37 (LBS.) 4105 18 2 SQL. .134 20 UL, FPL 17 (LBS.) 4106 18 4 SOL. .170 20 UL, FPL 29 (LBS.) 4107* 18 .6 SQL. .192 20 UL, FPL 41 (LBS.) 4108+ 18 '8 SQL. .208 20 UL, FPL 52 () 4109+ 18 10 SQL. .244 20 UL, FPL 68 (LBS.) 4110+ 16 .2 SQL .154 20 UL, FPL 24 (LBS.) 4111 16 4 SOL. .180 20 UL, FPL 43 (LBS.) 4112+ 14 2 'SQL .182 22 UL, FPL 35 (LBS.) 4113+ 14 4 SQL. .214 22 UL, FPL 64 (LBS.) 4114+ 12 2 SOL. .214 22 UL, FPL 52 (LBS.) 4115+ 'Not Twisted +Spools Only Fire Alarm Jacketed Unshielded, Direct Burial Applications: Wiring for Outdoor or Underground. Sunlight Resistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Risers and Plenums, but intended for Outdoor or Underground Use. Features: Available in 500 Ft. or 1000 Ft. Spools. Sequential Footage Markings. Construction: Stranded Copper Conductors, PVC Insulation, High Molecular Weight PVC Jacket Color: Black. Conductor Color Code Chart 4. FIRE ALARM JACKETED UNSHIELDED, DIRECT BURIAL 75' C NOM. NOM. CAR AVG. WE AWG #/COND. STR O.D. PF/FT LISTINGS PER MFT PART# 18 2 STR. .260 19 FPL, CL2 19 (LBS.) 4156 18 4 STR. .295. 19 FPL, CL2 15 (LBS.) 4157 18 6 , STR. .345 19 FPL, CL2 24 (LBS.) 4158 16 2 STR. .282 21 FPL, CL2 31 (LBS.) 4151 14 2 SIR. .310 23 FPL, CL2 37 (LBS.) 4153 14 4 STR. .355 23 FPL, CL2 17 (LBS.) 4154 'Not Twisted 20 Genesis Series Cable toll free 800.222.0060 phone 262.947.0720 fax 262.947.0724 Fire Alarm Jacketed Shielded (Overall Shield) Applications: Wiring of Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Risers and Plenums. Features: Available in 500 Ft. or 1000 Ft. Tangle-Free Boxes, or Spools. Sequential Footage Markings. Construction: Twisted Copper Conductors, Polypropylene Insulation, AluminurrilMylar Shield with Drain Wire applied overall the assembled conductors. Flexible Polyvinyl-Chloride Jacket. Standard Jacket Color: Red or White, Conductor Color Code Chart 4. FIRE ALARM JACKETED SHIELDED (OVERALL SHIELD) 75'C AWG #/COND. SOL NOM. O.D. NOM. CAR PF/FT LISTINGS AVG. WE PER MFT PART4$ 22 4 SOL. .124 31 UL, FPL 17 (LBS.) 4201 18 2 SQL. .138 42 UL, FPL 20 (LBS.) 4202 18 4 SOL. .160 42 UL, FPL 31 (LBS.) 4203 18 6 SQL. .196 42 UL, FPL 50 (LBS.) 4204 18 8 SQL. .212 42 UL, FPL 57 (LBS.) 4205+ 16 2 SOL. .158 46 UL, FPL 29 (LBS.) 4206 16 4. SOL. .186 46 UL, FPL 49 (LBS.) 4207+ 14 2 SQL. .186 52 UL, FPL 40 (LBS.) 4208+ 14 4 SOL. .218 52 UL, FPL 67 (LBS.) 4209+ 12 2 SQL. .218 56 UL, FPL 59 (LBS.) 4210+ i-Spools Only Fire Alarm Zipcord Applications: Wiring of Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Umited Circuits except those in Risers and Plenums. Features: Available in 500 Ft. or 1000 Ft. Tangle-Free Boxes, or Spools. One Conductor Ribbed for Polarity. Sequential Footage Markings, Construction: Copper Conductors Laid Parallel in a Zipcord Style. Integral Polyvinyl-Chloride Insulation. Standard Colors: Red, White, Black. FIRE ALARM ZIPCORD 75'C NOM. NOM. CAR AVG. WE AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART# 18 2 SQL. .105 x .217 17 UL, FPL, C(UL) CMG 18 (LBS.) 4002 16 2 SQL. .116 x.247 17 UL FPL, C(UL) CMG 39 (LBS.) 4003 14 2 SQL. .129 x .273 17 UL, FPL, C(UL) CMG 39 (LBS.) 4004 12 2 SQL. .146 x .307 17 UL, FPL, C(UL) CMG 55 (LBS.) 4005* consult factory for availability Honeywell : Fire Alarm Mid Cap Unshielded Applications: Wiring of Mid-Capacitance Addressable Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Risers and Plenums. Features: Available in 500 Ft. or 1000 Ft. Tangle-Free Boxes, or Spools. Sequential Footage Markings. Construction: Twisted Copper Conductors, Polypropylene Insulation, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red, Conductor Color Code Chart 4. FIRE ALARM MID CAP UNSHIELDED 75 C NOM. NOM. CAP. AVG. WI. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART# 18 2 SOL. .150 15 UL, FPL 17 (LBS.) 4050 - - 16 2 SOL. .170 17 UL, FPL 25 (LBS.) 4051+ 14 2 SQL. .208 19 UL, FPL 36 (LBS.) 4052+ +Spools Only Fire Alarm Mid Cap Shielded (Overall Shield) Applications: Wiring Of Mid-Capacitance Addressable Fire-Protective Signaling Circuits. Sunlight Resistant, Code Restrictions: OK for use with all Power-Limited Circuits except those in Risers and Plenums. Features: Available in 500 Ft. or 1000 Ft. Spools or Reel-in-the-Box. Sequential Footage Markings. Construction: Twisted Copper Conductors, Polypropylene Insulation, Aluminum/Mylar Shield with Drain Wire, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red, Conductor Color Code Chart 4. FIRE ALARM MID CAP SHIELDED OVERALL SHIELD) 75' C NOM. NOM. CAP. AVG. Wt AWG #/COND. SIR O.D. PF/FT LISTINGS PER MFT PART# 18 2 SQL. .150 32 UL, FPL 20 (LBS.) 4070 16 2 SOL. .170 36 UL, FPL 28 (LBS.) 407i-- 14 2 SQL. .210 37 UL, FPL 42 (LBS.) 4072+ +Spools Only 22 Genesis Series Cable toll tree 800.222.0060 phone 262.947.0720 fax 262.947.0724 Fire Alarm Jacketed Unshielded, Riser Rated Applications: Wiring of Fire-Protective Signaling Circuits. Sunlight Resisistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Plenums. Features: Available in 500 Ft. or 1000 Ft. Tangle-Free Boxes, or Spools. Sequential Footage Markings. Construction: Copper Conductors, Polypropylene Insulation, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red or White, Conductor Color Code Chart 4. FIRE ALARM JACKETED UNSHIELDED, RISER RATED 15t AWG #/COND. SOL NOM. O.D. NOM. CAR PF/FT LISTINGS AVG. WE PER MFT PART# 22 4 SQL. .122 15 UL, FPLR/CL2R, C(UL), 171-4 15 (LBS.) 4301 22 - 6 SOL. .144 15 UL, FPLR/CL2R, C(UL), FT4 19 (LBS.) 4302' 22 8 SQL. .156 15 UL, FPLR/CL2R, C(UL), FT4 25 (LBS.) 4303• 22 10 SQL. .182 15 UL, FPLR/CL2R, C(UL), FT4 30 (LBS.) 4304• 22 12 SQL. .188 15 UL, FPLR/CL2R, C(UL), FT4 36 (LBS.) 4305• 18 2 SQL. .138 19 UL, FPLR/CL2R,C(UL), FT4 17(LBS.)4306 184 SOL. .17419 UL, FPLR/CL2R, C(UL), FT4 34 (LBS.) 4307 18 6 SQL. .187 19 UL, FPLR/CL2R, C(UL), FT4 44 (LBS) 4308+ 18 8 SQL. .208 19 UL, FPLR/CL2R, C(UL), FT4 54 (LBS. 4309+ 1810 SOL. .24419 - UL, FPLR/CL2R,C(UL),FT467 (LBS.)4310+ 162 SOL. .16020 UL, FPLR/CL2R,C(UL),FT424 (LBS-) 4311 164 SOL. .18420 UL, FPLR/CL2R,C(UL), FT4 43 (LBS.) 4312+ 142 _ SOL. .18422 UL, FPLR/CL2R,C(UL),FT437 (LBS.)4313+ 14 4 SOL. .214 22 UL, FPLR/CL2R, C(UL), FT4 65 (LBS.) 4314+ 12 2 SQL. .214 22 UL, FPLR/CL2R, C(UL), FF4 55 (LBS.) 4315+ i-Spools Only Consult factory for availability. Fire Alarm Jacketed (Overall Shield), Riser Rated Applications: Wiring Of Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Plenums. Features: Available In 500 Ft. Or 1000 Ft. Tangle-free Boxes, or Spools. Sequential Footage Markings. Construction: Copper Conductors, Polypropylene Insulation, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red Or White, Conductor Color Code Chart 4. FIRE ALARM JACKETED (OVERALL SHIELD), RISER RATED 75 C AWG #/COND. SOL NOM. O.D. NOM. CAR PF/FT LISTINGS AVG. WE PER MFT PART# 22 4 SQL. .126 31 UL, FPLR/CL2R, C(UL), FT4 16 (LBS.) 4401 18 2 SQL. .138 42 UL, FPLR/CL2R, C(UL), FT4 21 (LBS.) 4402 18 4 SOL. .163 42 UL, FPLR/CL2R, C(UL), 1`174 32 (LBS.) 4403 18 -6 SOL. .19642 UL, FPLR/CL2R,C(UL),FT446(LBS.)4404 18 8 SQL. .212 42 UL, FPLR/CL2R, C(UL), FT4 56 (LBS.) 4405+ 16 2 SQL. .158 46 UL, FPLR/CL2R, C(UL), FT4 31 (LBS) 4406 16 4 SQL. .190 46 UL, FPLR/CL2R, C(UL), FT4 49 (LBS.) 4407+ 142 SOL. .19252 UL, FPLR/CL2R, C(UL), FT4 42(LBS.)4408+ 14 4 SQL. .218 52 UL, FPLR/CL2R, C(UL), FT4 72 (LBS.) 4409+ 12 2 SQL. .218 56 UL, FPLR/CL2R, C(UL), FT4 60 (LBS.) 4410+ +Spools Only Honeywell 23 Fire Alarm Zipcord, Riser Rated Applications; Wiring Of Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Plenums. Features: Available in 500 Ft. or 1000 Ft. Tangle-Free Boxes, or Spools. One Conductor Ribbed for Polarity. Sequential Footage Markings. Construction: Copper Conductors, Polyvinyl-Chloride Insulation. Standard Colors: White, Black, Blue, Red. FIRE ALARM ZIPCORD, RISER RATED 75' C NOM. NOM. CAP. AVG. Wt AWG .#/COND. SOL O.D. PF/FT LISTINGS PER MFT PART# 18 2 . SQL. .088 x .196 17 UL, FPLR/CL2R, C(UL), FT4 18 (LBS.) 4422 16 2 SQL. .094 x .200 17 UL, FPLR/CL2R, C(UL), FT4 26 (LBS.) 4423 14 2 SQL. .107 x .220 17 UL, FPLR/CL2R, C(UL), FT4 37 () 4424+ 12 2 SOL.. 124 x .250 17 UL, FPLR/CL2R, C(UL), FT4 52 (LBS.) 4425+ +Spools Only Fire Alarm Mid Cap Unshielded, Riser Rated Applications: Wiring Of Mid-Capacitance Addressable Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Limited Circuits except those in Plenums. Features: Available in 500 Ft. or 1000 Ft. Tangle-Free Boxes, or Spools. Sequential Footage Markings. Construction: Copper Conductors, Polypropylene Insulation, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red, Conductor Color Code Chart 4. FIRE ALARM MID CAP UNSHIELDED, RISER RATED 75 C NOM. NOM. CAR AVG. Wt AWG #/COND. SOL O.D. PF/FT LISTINGS PER Mn' PART# 18 2 SQL. .144 15 UL, FPLR/CL2R, C(UL), FT4 19 (LBS.) 4431 16 2 SOL. .170 17 UL, FPLR/CL2R, C(UL), FT4 26 (LBS.) 4432-i- 14 2 SOL. .208 19 UL, FPLR/CL2R, C(UL FT4 38 (LBS.) 4433+ 12 2 SOL. .256 22 UL, FPLR/CL2R, C(UL), 171-4 60 (LBS.) 4434-i-. +Spools Only Consult factory for availability 24 Genesis Series Cable toll free 800.222.0060 phone 262.947.0720 fax 262.947.0724 Fire Alarm Mid Cap Overall Shield, Riser Rated Applications: Wiring Of Mid-Capacitance Fire-Protective Signaling Circuits. Sunlight Resistant. Code Restrictions: OK for use with all Power-Umited Circuits except those in Plenums. Features: Available in 500 Ft. or 1000 Ft. Spools. Sequential Footage Markings. Construction: Twisted Copper Conductors, Polypropylene Insulation, Auminum/Mylar Shield with Drain Wire, Polyvinyl-Chloride Jacket. Standard Jacket Color: Red, Conductor Color Code Chart 4. FIRE ALARM MID CAP SHIELDED (OVERALL SHIELD) RISER RATED 75' C NOM. NOM. CAP. AVG. WI. AWG #/COND. SOL O.D. PFIFT LISTINGS PER MFT PART# 18 2 SQL. .148 34 UL, FPLR/CL2R, C(UL), FF4 21 (LBS.) 4441 16 2 SQL. .187 '38 UL, FPLR/CL2R, C(UL), FF4 32 (LBS.) 4442 14 2 SQL .212 41 UL, FPLR/CL2R, C(UL, FF4 43 (LBS.) 4443' 12 2 SQL. .260 48 UL, FPLR/CL2R, C(UL, FF4 48 (LBS.) 4444 Consult factory for availability. Honeywell 25 Fire Alarm Jacketed Unshielded, Plenum Rated Applications: Wiring Of Fire-Protective Signaling Circuits. Code Restrictions: OK for use with all Power-Limited Circuits. Features: Available in 500 Ft. or 1000 Ft. Tangle-Free Boxes, or Spools. Sequential Footage Markings. Construction: Copper Conductors, Low Smoke PVC Insulation, Low Smoke PVC Jacket And Ripcord. Standard Jacket Color: Red, Conductor Color Code Chart 4. FIRE ALARM JACKETED UNSHIELDED, PLENUM RATED 75' C NOM. NOM. CAR AVG. Wt AWG #ICOND. SOL O.D. PF/FT LISTINGS PER MFT PART# 22 4 SQL. .122 22 UL, FPLP/CL2P C(UL), FT6 15 (LBS.) 4501 22 6 SQL. .144 22 UL, FPLP/CL2P C(UL), FT6 21 (LBS.) 4502 22 8 SQL. .156 22 UL, FPLP/CL2P C(UL), FT6 28 (LBS) 4503 22 10 SOL. .182 22 UL, FPLP/CL2P C(UL), FT6 33 (LBS.) 45040 22 12 SQL. .188 22 UL, FPLP/CL2P C(UL), FT6 38 (LBS.) 4505 18 2 SOL. .134 24 UL, FPLP/CL2P C(UL), FT6 19 (LBS.) 4506 18 4 SQL. .156 24 UL, FPLP/CL2P C(UL), 1`1-6 32 (LBS.) 4507 18 6 SQL. .192 24 UL, FPLP/CL2P C(UL), F6 45 (LBS.) 4508+ 18 8 SQL. .208 24 UL, FPLP/CL2P C(UL), FT6 58 (LBS.) 4509+ 18 10 SQL. .244 24 UL, FPLP/CL2P C(UL), FT6 74 (LBS.) 4510+ 16 2 SOL. .154 27 UL, FPLP/CL2P C(UL), FT6 26 (LBS.) 4511 16 4 SOL. .180 27 UL, FPLP/CL2P C(UL), FT6 47 (LBS.) 4512+ 14 2 SOL. .182 27 UL, FPLP/CL2P C(UL), FT6 38 (LBS.) 4513+ 14 4 SQL. .214 27 UL, FPLP/CL2P C(UL), FF6 68 (LBS.) 4514+ 12 2 SOL. .214 30 UL, FPLP/CL2P C(UL), F16 55 (LBS.) 4515+ +Spools Only consult factory for availability Fire Alarm Jacketed Overall Shield, Plenum Rated Applications: Wiring 01 Fire-Protective Signaling Circuits. Code Restrictions: OK for use with all Power-Limited Circuits. Features: Available In 500 Ft. Or 1000 Ft. Tangle-free Boxes, or Spools. Sequential Footage Markings. Construction: Twisted Copper Conductors, Low Smoke PVC Insulation, Aluminum/Mylar Shield With Drain Wire Low Smoke PVC Jacket and Ripcord. Standard Jacket Color: Red, Conductor Color Code Chart 4. FIRE ALARM JACKETED SHIELDED (OVERALL SHIELD) PLENUM RATED 75°C NOM. NOM. CAP. AVG. WT. AWG #/COND. SOL O.D. PF/FT LISTINGS PER MFT PART# 22 4 SQL. -.126 53 UL, FPLP/CL2P C(UL, FT6 18 (LBS.) 4601 18 2 SQL. .140 68 UL, FPLP/CL2P C(UL), FF6 22 (LBS.) 4602 18 4 SQL. .168 68 UL, FPLP/CL2P C(UL), FT6 35 (LBS.) 4603 18 6 SOL. .196 68 UL, FPLP/CL2P cjUL, FT6 50 (LBS.) 4604+ 18 8 SQL. .212 68 UL, FPLP/CL2P C(UL), FT6 62 (LBS.) 4605+ 16 2 SQL. .158 77 UL, FPLP/CL2P C(UL), FT6 35 LEIS) 4606 16 4 SQL. .186 77 UL, FPLP/CL2P C(UL), FF6 52 (LBS.) 4607+ 14 2 SQL. .186 86 UL, FPLP/CL2P C(UL), FT6 44 LBS.) 4608+ 14 4 SQL. .218 86 UL, FPLP/CL2P C(UL), FT6 75 LBS.) 4609+ 12 2 SQL. .218 96 UL, FPLP/CL2P C(UL), FT6 63 LBS.) 4610+ +Spools Only 26 Genesis Series Cable toll free 800.222.0060 phone 262.947.0720 fax 262.947.0724 Fire Alarm Midcap Unshielded, Plenum Rated Applications: Wiring Of Mid-Capacitance Addressable Fire-Protective Signaling Circuits. Code Restrictions: OK for use with all Power-Limited Circuits. Features: Available In 500 R. Or 1000 Ft. Spools. Sequential Footage Markings. Construction: Copper Conductors, Auoropolymer Insulation, Low Smoke PVC Jacket and Ripcord. Standard Jacket Color: Red, Conductor Color Code Chart 4. FIRE ALARM MIDCAP UNSHIELDED, PLENUM RATED 75 C NOM. NOM. CAP. AVG. WE AWG #/COND. SOL O.D. PF1FT LISTINGS PER MFT PART# 18 2 SOL. .146 16 UL, FPLP/CL2P C(UL), FF6 21 (LBS.) 4631. 16 21 SOL. .182 16 UL, FPLP/CL2P C(UL), FF6 29 (LBS.) 4632' 14 2 SOL. .210 16 UL, FPLP/CL2P C(UL), FT6 42 (LBS.) 46330 Consult factory for availability. Fire Alarm Midcap Overall Shield, Plenum Rated Applications: Wiring Of Mid-Capacitance Fire-Protective Signaling Circuits. Code Restrictions: OK for use with all Power-Limited Circuits. Features: Available in 500 Ft. or 1000 Ft. Spools. Sequential Footage Markings. Construction: Copper Conductors, Fluoropolymer Insulation, Aluminum/Mylar Shield with Drain Wire, Low Smoke PVC Jacket and Ripcord. Standard Jacket Color: Red, Conductor Color Code Chart 4. FIRE ALARM MIDCAP SHIELDED (OVERALL SHIELD) PLENUM RATED 75' NOM. NOM. CAR AVG. WI. AWG #/COND. SOL O.D. PFIFT LISTINGS PER Mfl PART# 18 2 SQL. .150 32 UL, FPLP/CL2P C(UL), FT6 25 (LBS.) 4641 16 2 SQL. .187 32 UL, FPLP/CL2P C(UL), FT6 39 (LBS, 4642 14 2 SQL. .214 32 UL, FPLP/CL2P C(UL), F16 52 (LBS.) 4643' Consult factory for availability Honeywell 27 HNIR.E175105 - Power-limited Fire Alarm Cable U Underwriters L Laboratories Inc. HNIR.E175105 Power-limited Fire Alarm Cable Page Bottom Print-friendly version Questions? I PrèviousPge I Power-limited Fire Alarm Cable See General Information for Power-limited Fire Alarm Cable GENESIS CABLE SYSTEMS L L C 7701 95TH ST PLEASANT PRAIRIE, WI 53158 USA E175105 Types FPL , FPLP, FPLR. Type FPLP also classified for use as fire alarm cable in New York City. Last Updated on 1998-04-09 Page Top Notice of Disclaimer Questions? IPrevious Page UL Listed and Classified UL Recognized Products Certified Products Components for Canada This page and all contents are Copyright © 2005 by Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the file:///GI/Steve%20Carnahan/HNIR_E 175 1050/o20-%20Power-limited%20Fire%20Alarm%20Cable.htm (1 of 2)4/18/2005 10:23:45 AM }INIR.E175 105 - Power-limited Fire Alarm Cable product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2005 Underwriters Laboratories Inc.®" file:///GlfSteve%20CarnahanIHNIR_E I75105%20-%20Power-limited%20Fire%2OAlarm%20Cabte.htm (2 of 2)4/18/2005 10:23:45 AM CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 4 LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. W2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. ModelW RC2R, Model C2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to + 151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes° can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 11 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL LISTING SERVICE LISTING No. 7272-0075:0194 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Models 5D350, SD350T,(D355SD355R*, 5D355T and AD355 photoelectric type smoke detectors. Model 5D350T and 5D3551 has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 0-4,000 FPM. Models SD355 and SD355R* are also approved for installations inside Fire-Lite Duct Housing D355PL (CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW(CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-11-2010 fm 0' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL Ilk LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-I2LWP, BG-12L, [BG-12L BG-12LA, BG-12PS, BG-12LSP, BG-125P, BG-12LR, BG-12LRA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-12SL, UT-PSi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be. used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 907 MIQ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywelI.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models (CRF-300)and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 15-32V0C INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listees separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CAST1LLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION . OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM IL Ilk LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywelI.com DESIGN: Models MDF-300, MMF-301,M0) MMF-302, MCF-300 monitor modules: Models and CMF-300 control modules: and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations: RATING: 15-32VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: Rev. 05-06-05 JW , This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0075:0190 Page 1 of 1 CATEGORY: 7120 --(ANNUNCIATORS) LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Model LCD-80F remote fire annunciator. Unit is a compactFOcharacter, backlit LCD fire annunciator. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator for use separately listed compatible fire alarm control units. NOTE: XLF: 7120-0028:209 *Rev. 05-06-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM b, LISTING SERVICE LISTING No. 7165-0075:0208 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Models and MS-9200UDLS addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VOC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *MS..9200UDLS panel also suitable for high-rise application for use with Model ECC-50/100 emergency voice evacuation panel (CSFM #6911-0075:0226). This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 11-12-13gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0110 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: 1b'Jë\17.j..V001, *TG7LvA01 0TG7LVF01 and TG-KIT digital cellular communicator system. Models are digital cellular radio alarm transmission devices used to provide a primary (sole or with a back-up) or back-up transmission path using cellular for control communicators. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: 120 Vac INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. *04-07-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0186 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywell.com DESIGN: Synchronous type strobe lights, ModelsERD SRH SW-CLR-ALERT, SWH, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135, *150, *177 *185cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. Rev. 03-11-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division