Loading...
HomeMy WebLinkAbout2641 GATEWAY RD; 101; FPC2020-0211; PermitCL7city of PERMIT REPORT S Carlsbad Print Date: 04/08/2021 Permit No: FPC2020-0211 Job Address: 2641 GATEWAY RD, # 101, CARLSBAD, CA 92009-1754 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2131912500 Track #: Applied: 12/17/2020 Valuation: $95,008.96 Lot #: Issued: 12/29/2020 Occupancy Group: Project #: Finaled Close Out: 04/08/2021 #f Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: PANDA EXPRESS -SPRINKLER TI (28 HEADS) Applicant: FPContractor: WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC MARIO MACK 13630 DANIELSON ST 13630 DANIELSON ST P0 WAY, CA 92064-6830 POWAY, CA 92064-6830 (858) 513-4949 (858) 513-4949 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads S $553.00 TotaF Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov QUICK RESPONSE GL mum a BE FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION AUTOMATIC SPRINKLERS GL SERIES RECESSED PENDENT TO MEET IBC-ASCE/SEI 7 CODES FOR SEISMIC AREAS C, D & E The Globe Quick Response GL Series Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature, the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The use of the 4112" diameter recessed escutcheon allows for 1" of clearance around the sprinkler body, and meets the IBC-ASCEISEI 7 requirements for use in seismic design categories C, D & E. The sprinkler and escutcheon are not factory assembled. Assembly is done at the time of installation. TECHNICAL DATA See reverse side for Approvals and Specifications. 'Temperature Ratings - 135°F (570C), 155°F (68°C), 175°F f (790C), 200°F (930C), 286°F (141°C) ; ) Water Working Pressure Rating - 175 psi (12 Bars) / Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass QUICK RESPONSE Bulb seat - copper • Spring - nickel alloy • Seal - teflon RECESSED PENDENT Bulb - glass with alcohol based solution, 3mm size WITH OPTIONAL 41/2" SEISMIC Escutcheon Assembly - steel RECESSED ESCUTCHEON SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER BULB N.F.P.A. MAXIMUM CLASSIFICATION TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY 1350F/155°F 570C1680C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F1200°F 79°C193°C YELLOW/GREEN 150°F 66°C HIGH 286°F 141°C BLUE 225°F 107°C 4O77AIRPARKDRIVE, STANDISH, MICHIGAN 48658 989-846-4583 9 FAX989-846-9231 APRIL 2009 A-24E0 BULLETIN GL2801-EQ QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES RECESSED PENDENT TO MEET IBC-ASCE/SEI 7 CODES FOR SEISMIC AREAS C, D & E SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES 2.8 (39 metric) 1/2' NPT 2 1/4" (5.7 cm) 4.2 (59 metric) 1/2' NPT 2 1/4' (5.7 cm) Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester' 7.8 (111 metric) 1/2' NPT 2 1/4" (5.7 cm) 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'cULus LISTED CORROSION RESISTANT - POLYESTER MUST BE SPECIFIED ON ORDER. APPROVALS STYLE SIN K 135°F 155°F 175°F 200°F **286F cULus LPC CE NYC - DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C FM MEA101-92-E GL2801 2.8 X X X X X X - - - x GL4201 4.2 X X X X X X - - - X PENDENT GL5601 5.6t X X X X X X X X X X RECESSED GL8101 7.8t X X X X X X X - - X GI-8106, 8.1t X X I X I X X X I X I X I X X t5.6K ORIFICE, 7.8K ORIFICE AND 8.11< ORIFICE LISTED FOR ALL HAZARDS. °286°F cULus LISTED ONLY. t 1/2' RECESSED ESCUTCHEONS ARE REQUIRED FOR FM APPROVED SPRINKLERS. ORDERING INFORMATION SPECIFY Quantity • Model Number . Style Orifice • Thread Sizes • Temperature Finishes desired Quantity - Recessed Wrenches - P/N 325391 (1/2"); 1/8'MIN. P/N 325401, Rev. F (L.O.) 5/8° MAX. - 1/2' AD). 7/8' MAX. -3/4'ADJ. • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed) GLOBES PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty, please refer to Price List Terms and Conditions of Sale (Our Price List). 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX989-846-9231 1-800-248-0278 www.globespnnkIer.com CROSS SECTIONS —4 112' DIA.- 7/8'-4'DIA.MIN. 1° x 1/2' HOLE IN cElUNG REDUCER —129/32' DIA.- 1' MIN. 13/4' MAX. PENDENT WITH OPTIONAL IBC SEISMIC RECESSED ESCUTCHEON GLb)13E FIRE SPRINKLER CORPORATION APRIL 2009 PRINTEDU.S.A. BULLETIN GL2801-EQ GLbRE FIRE SPRINKLER CORPORATION DESCRIPTION AND OPERATION QUICK RESPONSE "THE INCH" MODEL GL5606 ONE INCH ADJUSTABLE CONCEALED PENDENT WITH COVER PLATE TO MEET lB C-A SCE/SEI 7 CODES FOR SEISMIC AREAS C, D & E The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It provides sprinkler operation approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified, when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. The 4 1/2" diameter cover plate allows for 1" clearance around the sprinkler body, and meets the IBC-ASCE/SEI 7 requirements for the use in seismic design categories C, D & E. The GL Series Concealed Sprinkler may be virtually invisible, as it does not interrupt the "smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate. The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off' designed cover plate is easilyinstalled and with a nominal I" inch of adjustment makes it easier to get a proper fit at the ceiling. Operation of the sprinkler occurs when heat build-up causes the solder holding the cover plate to the support shell to melt, allowing the cover plate to fall clear. Continued heat build-up causes the 3mm glass bulb to burst, allowing the deflectorto drop down and distribute water in an approved pattern to extinguish or control the fire. TECHNICAL DATA See reverse side for Approval and Specifications. Temperature Ratings- 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate 155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate Water Working Pressure Rating - 175 psi 112 Bars) Factory tested hydrostatically to 500 psi (34 Bars) - Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE Frame - bronze. Deflector - brass. Screw - brass 4 1/2" diameter plate Bulb Seat - brass • Spring - nickel alloy • Seal - teflon WHITE Bulb - glass with alcohol based solution, 3mm size ADJUSTABLE Drop Pin - stainless steel • Cover Plate - brass CONCEALED PENDENT Upper Escutcheon Assembly - plated steel NOTE: Globe's wrench P/N 332765 must be used to install this sprinkler. SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION BULB COLOR TEMPERATURES CEILING TEMPERATURE ORDINARY 1350F/ 1550F 57°C /680C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F / 200°F 79°C /93'C YELLOW/GREEN 150°F 66°C 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 (989) 846-4583 • FAX 989-846-9231 APRIL 2009 A-38-EQ BULLETIN GL5606-EQ REV#2 QUICK RESPONSE MODEL GL5606 ONE INCH ADJUSTABLE CONCEALED PENDENT WITH COVER PLATE TO MEET IBC-ASCE/SEI 7 CODES FOR SEISMIC AREAS C. D & E SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES Chrome 5.6 (80 metric) 1/2" NPT 2 1/2" (6.4 cm) White NOTE: METRIC CONVERSIONS ARE APPROXIMATE. APPROVALS SIN K 135°F (57°C) 155°F (68°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) STYLE MODEL FACTOR with plate with plate with plate with plate with plate c1JLus 135°F (57°C) 135°F (57°C) 155°F (68°C) 155°F (68°C) 155°F (68°C) Adjustable Concealed GL5606 5.6 X X X X X X Pendent CROSS SECTION 7/8" -4" DIX. MIN. HOLE IN CEILING DIV. DROP PIN 2 3/4" MAX. I 7/8" MIN. SUPPORT SHELL CEILING COVER PLATE 41/2" CEILING PLATES WHITE 135°F PART# WHITE 155°F PART# CHROME 135°F PART# CHROME 155°F PART# 332822 332828 332821 332827 ORDERING INFORMATION SPECIFY Quantity • Model Number Style Orifice • Thread Sizes • Temperature Finishes desired Quantity - Adjustable Concealed Wrenches - P/N 332765 GLt)BE FIRE SPRINKLER CORPORATION APRIL 2009 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty, please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.gIobesprinkler.com PRINTED U.S.A. BULLETIN GL5606-EQ REV#2 .rc QUICK RESPONSE SERIES GL-QR SERIES GL-QRJCNV UPRIGHT CONVENTIONAL D QUICK RESPONSE SERIES GL-QR SERIES GL-QRISW PENDENT VERTICAL SIDEWALL 00012 IVNIQ VIP" gliiR3 FIRE SPRINKLER CORPORATION QUICK RESPONSE A U TO MA TI C SPRINKLERS GL SERIES UPRIGHT ° PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response Series GL-QR Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the ap- plicable standards. It offers the additional feature of greatly in- creased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used ad- visedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Series GL-QR sprinkler proven ac- tuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the inter- nal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. C9 Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (79°C), 200°F (93°C), 286°F (141°C) 0 a, Water Working Pressure Rating - 175 psi (12 Bars) QUICK RESPONSE Factory tested hydrostatically to 500 psi (34 Bars) HORIZONTAL LPCB/CE Maximum low temperature glass bulb rating is -67°F (-55°C) SIDEWALL HORIZONTAL Frame - bronze • Deflector - brass • Screw - brass SERIES GL-QRISW SIDEWALL Lodgement Wire - stainless steel • Bulb seat - copper SERIES GL-QRISW Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION BULB COLOR TEMPERATURES CEILING TEMPERATURE ORDINARY F H 1oi F 57 G bd C ORANGE/RED 38 C INTERMEDIATE 700F 7cyc93c YELLOW/GREEN 150 F 66C HIGH 141 C BLUE 725 F 107C MAR 2018 GFS-100a (Formerly A-20) QUICK RESPONSE A U TO MA TIC SPRINKLERS UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL. "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4 (5.7cm) Chrome White Polyester' 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester 2.3 8.0 (115 metric) I 3/4'NPT (20mm) 27/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 29/16". °FINISHES AVAILABLE ON SPECIAL ORDER. 3AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. LISTINGS/APPROVALS K TEMPERATURE NYC - DOB _____ 135°F 155°F 175°F 200°F 286°F STYLE SIN FACTOR HAZARD' cULus FM LPCB2 CE MEA (57°C) (68°C) (79°C) (93°C) (141°C) 101-92-E GL2815 2.8 LH X X X X X X -- X GL4215 4.2 LH X X X X X X --- -- --- X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115° 8.0°(WNPT) LH/OH X X X X X -' X --- -- -- X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X X GL4201 4.2 LH X X X X X X - X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101° 8.0° (W NPT) LH/OH X X X X X X - - . .X - - GL8106 8.0 LH/OH X X X X X X X X ( X VERTICAL GL5632 5.6 LH X X X X X X X -- SIDEWALLt GL8133 8.0 .LH X X X X X X -- GL2826 2.8 LH X X X X X X - -- - X HORIZONTAL GL4226 4.2 LH X X X X X X --- --- SIDEWALL GL5626 5.6 LH/OH X X X X X X X - X GL5627a 5.6 LH/OH X X X X X --- --- X X GL8127 8.0 LH/OH X X X X X X - CONVENTIONAL GL5624 5.6 LH/OH X X X X X --- --- X X - (OLD STYLE) GL8125 8.0 LH/OH I X X X I X X --- -- --- X -- 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. BINSTALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. fUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD "1/2" NPT, FOR RETROFIT ONLY 2LPCB REF. NO. 147c/05 ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity • SIN • Style • Orifice products found to be defective in material or workmanship for a Thread Size • Temperature Finishes desired period of one year from date of shipment. Quantity - Wrenches - PIN 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). GLBE FIRE SPRINKLER CORPORATION MAR 2018 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.gIobesprinkler.com PRINTED U .S.A. GFS-1 00a (Formerly A-20) QUICK RESPONSE A U TOMA TI C SPRINKLERS Bonn NIFFA 6 L ___ GL SERIES DRY TYPE FIRE SPRINKLER CORPORATION RECESSED PENDENT TO MEET IBC-ASCE/SEI 7 CODES FOR SEISMIC AREAS C. D & E DESCRIPTION AND OPERATION The Globe Quick Response Series GL-QR/DRY Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Globe Quick Response Series GL-QRIDRY Pendent Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's Series GL-QR/DRY sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. The use of the 41/2" diameter recessed escutcheon allows for 1" of clearance around the sprinkler body, and meets the IBC-ASCE/SEI 7 requirements for use in seismic design categories C, D & E. The sprinkler and escutcheon are not factory assembled. Assembly is done at the time of installation. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C) 155°F (68°C), 175°F (79°C) 200°F (93°C), 286°F (141°C) Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass• Screw - brass Bulb Seat - brass• Spring - nickel alloy' Seal - teflon Retainer - brass • Pin - stainless steel Torsion Spring - stainless steel• Orifice Insert - brass Bulb - glass with alcohol based solution, 3mm size 3/4"NPT or 1"NPT • Outer Tube - galvanized steel pipe Inner Tube - stainless steel SERIES GL-QRJDRY RECESSED PENDENT WITH OPTIONAL 41/2" SEISMIC RECESSED ESCUTCHEON NOTE: Globe's wrench P/N 337014 must be used to install this sprinkler. 0 SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY 135°F/155°F 57°C/68°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C193°C YELLOW/GREEN 150°F 66°C HIGH 286°F 141°C BLUE 225°F 107°C DEC 2017 GFS-505a-EQ (Formerly A-55EQ) CROSS SECTION .. , . - . ' ...,.-TEEFIT11NG I I,.. ANSI 616.3 CLASS 150 OR r ANSI 616.4 CLASS 125 PENDENT WITH OPTIONAL IBC SEISMIC RECESSED ESCUTCHEON QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE RECESSED PENDENT TO MEET lB C-AS CE/SEI 7 CODES FOR SEISMIC AREAS C, D & E SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH FINISHES 5.6 (80 metric) 3/4' or 1"NPT cULus Variable to 48" FM Variable to 36' Chrome White Polyester2 8.0 (115 metric) 1"NPT NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 2cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS K THREAD 135°F 155°F 175°F 200°F 286°F NYC-DOB STYLE SIN FACTOR SIZE HAZARD' (57°C) (68°C) (79°C) (93°C) (141°C) *FM cULus MEA 101-92-E GL5635 5.6 1'NPT LH/OH X X X X X X X X RECESSED GL5636 5.6 3/4"NPT LH/OH X X X X X -- X X PENDENT GL8135 8.0 1"NPT LHIOH X X X X X --- X X 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. "FM APPROVED FOR 155°F (68°C) AND 200°F (93°C) ONLY. LH: LIGHT HAZARD; OH: ORDINARY HAZARD IMPORTANT INSTALLATION DATA Globe GL Series Dry Pendent Sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit. When installed in a wet system extending into a freezing area see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs. Please refer to our Dry Caution Sheet for further important installation data. ORDERING INFORMATION SPECIFY MPr Quantity ° SIN• Style" Orifice Temperature Finishes desired• Quantity - Recessed Wrenches - PIN 337014 ° Quantity - Protective Caps - P/N 327109-cap (Friction Fit Recessed) "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used. GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). I ; FIRE SPRINKLER CORPORATION DEC 2017 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.gIobesprinkler.com PRINTED U.S.A. GFS-505a-EQ (Formerly A-55EQ)