Loading...
HomeMy WebLinkAbout2634 GATEWAY RD; ; FPC2018-0148; PermitPERMIT REPORT Ccity of Carlsbad Print Date: 10/18/2021 Permit No: FPC2018-0148 Job Address: 2634 GATEWAY RD, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2132621900 Track #: Valuation: $2,368,710.88 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: UPTOWN BRESSI RANCH Description: SPROUTS -INSTALLATION OF NEW FIRE ALARM SYSTEM Fire Alarm Applied: 05/15/2018 Issued: 05/31/2018 DEV12023 Finaled Close Out: 05/26/2021 Inspector: Final Inspection: FPContractor: KOR FIRE ALARM AND ELECTRONIC SECURITY 17853 SANTIAGO BLVD, # STE 107-216 VILLA PARK, CA 92861-4113 (714) 349-1435 FEE AMOUNT FIRE New Alarm System $1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov SUBMITTAL BOOKLET FOR Sprouts Carlsbad 2634 Gateway Road Carlsbad, CA 92009 \ LJ FIRE & SECURITY "Our Knowledge Is Your Security" 17853 Santiago Blvd., Ste 107-216 Villa Park, CA 92861 California State License: 1036776 www.boschsecurity.com 0 BOSCH , Invented for life Four initiating zones (expandable to eight); up to 20 two-wire smoke detectors per zone ' Built-in DACT Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A NAC power supply ' Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module Programmable through front panel interface, remote FMR-7033 Liquid-crystal Display (LCD) Keypads, remote programming software (RPS), or DX401OV2 or DX4020 The FPD-7024 Fire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. They are listed by UL for central station, local, auxiliary, and remote station systems. The FPD-7024 FACPs support four on-board initiating zones that can be expanded to eight using the FPC-7034. Each initiating zone supports two-wire and four-wire detectors configurable as Class A , Style D or Class B, Style B loops. Each zone can support up to 20 two-wire detectors, or any number of four-wire detectors depending on available power. Each FACP has a built-in digital fire alarm communicator transmitter (DACT). Enhance the FPD-7024 conventional system features by adding a D7039 Multiplex Expansion Module. Adding a D7039 Multiplex Expansion Module to the FPD-7024 turns the conventional FACP into an addressable FACP. The D7039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 19 to 59 and expands system users to 100. Notification Appliance Circuits (NACs) Two Class A, Style Z or Class B, Style Y NACs provide up to 4 A of regulated 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, California March, steady, pulsed, and synchronized output for Wheelock, Gentex, or System Sensor notification appliances. User Interface A viewing port in the locked control panel enclosure door shows the system status light-emitting diodes (LEDs) and liquid-crystal display (LCD) while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing off-normal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all FMR-7033 LCD Keypads connected to the system. 2 I FPD-7024 Fire Alarm Control Panels I Organized Event Display Sorts alarm, trouble, and supervisory events into categories and allows scrolling through specific events. History Buffer The system stores events in a 99-event history buffer. Notice The number of events that can be stored in the history buffer increases to 499 with the addition of a D7039 Multiplex Expansion Module. Central Station Reporting The FPD-7024 FACPs send reports to two telephone numbers (or IP addresses with a DX4020 Network Interface Module installed) with full single, double, and backup reporting. They communicate in BFSK, SlA, Contact ID, Modem lIla2, and 4/2 and 3/1 Tone Bursts. Dirty Smoke Detector Monitoring All on-board zones and FPC-7034 zones are continuously monitored for smoke detectors signaling a dirty condition using the Bosch Chamber Check feature and CleanMe protocol. If a detector's smoke chamber is dirty, the detector sends a CleanMe signal on the two-wire loop or a dirty detector signal on the addressable loop. The control panel annunciates that there is a dirty detector on the loop or the address. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head. Accessories The FPD-7024 enclosure has space for additional accessory modules and two D1218 (18 Ah) batteries or two D126 (7 Ah) batteries. Region Certification USA FCC ESVAL04B7024 - FM - CSFM 7165-1615:0227 - - FDNY- #6024 CoA Brazil ANATEL 0383111855 USA UL UOJZ: Control Units, System (ANSI/UL 864) Compatible Products The following products are compatible with the FPD-7024 FACP: Category Product ID Product Description Batteries and D126 12V, 7 A battery Power Supplies D1218 12V, 18 Ah battery D7038 Remote NAC power supply Detectors For two-wire detector compatibility, refer to FPD-7024 Smoke Detector Compatibility List Technogram (P/N: F01U010790) Keypads and 07030X Eight-point LED annunciator Annunciators (eight red) 07030X-52 Eight-point LED annunciator (two yellow, six red) D7030X-58 Eight-point LED annunciator (eight yellow) D7032 Eight-point LED annunciator expander (eight red) FMR-7033 LCD fire system keypad FMR-7036 LCD annunciator Modules 0132B Smoke detector reversing relay module D184A Local energy kit D185 Reversing polarity module D275 EOL power supervision module FPC-7034 Four-point expander 07039 Multiplex expansion module Option Bus 07035 Octal relay module Devices 07035B Octal relay module in box DX401OV2 USB/serial interface module 0X4020 Network interface module 8420 Ethernet Communicator 8420-CN Ethernet Communicator for China NAC Devices Refer to FPD-7024 Device Compatibility List Technogram(P/N: F01U010791) The following additional products are compatible with the FPD-7024 Addressable FACPs: Category Product ID Detector Heads 07050 and Bases D7O5OTH D7050-B6 Modules D7042 D7042B 07044 Product Description Addressable Photoelectric Smoke Detector Head Addressable Photoelectric Smoke and Heat Detector Head Detector Base Multiplex eight-input remote module Multiplex eight-input remote module in box Multiplex single-input module D7044M Mini multiplex single-input module D7048 Multiplex octal driver D7048B Multiplex octal driver in box D7052 Multiplex dual-input module D7053 Multiplex input-output module Pull Stations FMM-7045 Single-action manual station FMM-7045-D Double-action manual station FPD•7024 Quant. Component 1 FPD-7024 board in a static-resistant bag 1 Enclosure 1 Lock set with two #1358 (D102) keys (P1 N: F01U083084) 1 Transformer (P/N: FO 1U033706) 6 2.21 k() end-of-line (EOL) resistors (P/N: F01U034504) 1 Hardware pack 1 Literature pack Notice For the FPD-7024 to be addressable, a D7039 Multiplex Expansion Module must be installed. The D7039 is purchased separately. FPD•7024-LC Quant. Component 1 FPD-7024 board in a static-resistant bag 1 Hardware pack 1 Literature pack FPD-7024-LT Quant. Component 1 FPD-7024 board in a static-resistant bag 1 Enclosure 1 Lock set with two 41358 (D102) keys (PI N: F01U083084) 6 2.21 kU end-of-line (EOL) resistors (P/N: f0iU034504) 1 Hardware pack 1 Literature pack FPD-7024-A Quant. Component 1 FPD-7024-A board in a static-resistant bag 1 Enclosure 1 Lock set with two 41358 (D102) keys (P1 N: F01U083084) 1 Transformer (P/N: F01U033706) 6 2.21 kfl end-of-line (EOL) resistors (P/N: F01U034504) 1 Hardware pack 1 Literature pack FPC•7024-FK1 Quant. Component 1 FPD-7024FACP 1 1`220-86E 6-in. (15.24-cm) diameter, 4-wire base with EOL relay 1 F220-P photoelectric spot smoke detector 1 FMM-100SATK manual station (red) 2 D162@24 2-ft (60.96-cm) dual modular phone cord 2 D166@24 RJ31X phone jack Electrical Current (alarm): 380 mA Current (standby): 200 mA Power (primary): 120 VAC, 1.2 A maximum, 60 Hz or 240 VAC 0.75 A maximum, 50 Hz Environmental Environment: Indoor, dry Relative Humidity: Up to 95%, non-condensing Temperature (operating): +32°F (0°C) to +120°F (+49°C) Mechanical Properties Color: Red Dimensions (HxWxD): 20.8 in. x 15 in. x 4.3 in. (52.8 cm 38.1 cm 10.9 cm) Material: Cold-rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) Indicating Device Circuits (IDC) Current: 44 mA maximum per loop Line resistance: 1500 Voltage: 24 VDC nominal 4 I FPD-7024 Fire Alarm Control Panels I Outputs NAC: 24 VDC nominal, 4 A maximum On-board Relays: Three Form C contacts rated at 5 A, 28 VDC Off-board Relays: Up to two D7035 Octal Relay Modules with each providing eight Form C relay outputs; contacts rated at 5 A, 28 VDC In an addressable system, up to 20 D7053 Multiplex Input-Output Modules are allowed per bus fora total of 40 Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. FPD-7024 FACP Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone Order number FPD-7024 FPD-7024-LC FACP without Enclosure and Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone Order number FPD-7024-LC FPD-7024LT FACP without Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone. Available only in Latin America. Order number FPD-7024-LT FPD-7024-A Fire Alarm Control Panel for Anatel Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone. Has Anatel approval for use in Brazil. Order number FPD-7024-A D102 Replacement Key Replacement key (#1358) for LOCK-1358 and the D1O1 lock. Order number 0102 Accessories Basic Fire Panel Kit Four-zone FACP with one four-wire photoelectric smoke detector and base with EOL relay, one two-wire horn/strobe, one manual station, and two RJ31X phone jacks with dual modular phone cords. Order number FPC-7024-FK1 R.pres.nt.d by, An,erlcan, Europe, Middle East, Africa, Asia-Pacific, China, America Latina, Bosch Security Systems. Inc. Bosch Security Systems B.V. Robert Bosci, (SEA) rte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Busch Ltdo Security Systems Division 130 Perinton Parkway P.O. Boo 80002 Systems 201 Building. NO. 333 Fuqaun Road Via Anhanguera, Km 98 Fairport. New York, 14490, USA 5617 BA Kindhovnn, The Netherlands 11 Blshan Street 21 North IBP CEP 13060-900 Phone: 01 800 289 0098 Phone: • 3140 2577 284 Singapore 173943 Changning District, Shanghai Campinas. Sao Paulo. Brazil Fax: +1 585 223 9180 Fax: +3140 2577 330 Phone: +65 6571 2808 200335 China Phone: +55 19 2103 2860 security.szles@os.bosch.com ensea.securitysysternscpbosch.cum Fan: +65 6571 2699 Phase 08621 22181111 Fan: n55 19 2103 2862 www.boschsecurity.us www.boschsecurity.cum apr.secuntysystemn@bosch.com Fax: *86 2122182398 aI.securitysystemsbosch.com www.bnschsecurity asia www.boschsecurity.com.cn wv.'w.botchsecurjty.com O Botch Security Systems 2013 ( Data subject to change without notice 2692228235 1 an, '/9, 22. Feb 2013 www.boschsecurity.com 0 BOSCH Invented for life Enables full two-way IP communication using Plug-in Cellular Communicators Plug and Play installation makes future radio technology changes easy Compatible with new and most deployed Bosch control panels Supports remote installation of cellular modules for improved signal The B450 Conettix Plug-in Communicator Interface is a four-wire powered SDI2, SDI, or option bus device that provides two-way communication with compatible control panels over commercial cellular networks using a plug-in communicator (available separately). Use B450 in combination with a plug-in communicator for primary or backup alarm communication, remote panel programming and other remote applications. The B450 supports Conettix IP protocol with full authentication, 256 bit AES encryption and resistance to Denial of Service attacks. It is a reliable way to add cellular network communications to existing or new commercial security and fire installations. B450 system overview Callout - Description Callout - Description Compatible Bosch control 6- Cellular carrier network panel Panel data bus (SD12, SDI. or 7-Internet/LAN/WAN Option) B450 Plug-in Communicator 8- Remote Programming Interface Workstation 2 I B450 Conettix Plug-in Communicator Interface USB connection for B450 9-Bosch Conettix IP receiver configuration (D6600, D6100i, or D6100IPv6) B44x Plug-in Cellular Communicator (available separately) Conettix IP communication The B450 uses Conettix IP protocol which supports: Full event code reporting and administration Flexible supervision intervals Resistance to Denial of Service attacks 128, 192 or 256-bit AES encryption Anti-replay and anti-substitution Switch addressing Use the address switch to easily assign a bus address or setup for USB or SMS configuration where required. Easy configuration For most installations, the default B450 settings allow installation with no device programming required. An address switch allows easy bus address selection. For customized network settings, the B450 supports a USB configuration menu, or configuration via SMS. B Series and GV4 Series control panels support limited keypad and RPS programming of B450 settings. LEDs Three LEDs provide status and troubleshooting information about the module and its connection. LED Description Heartbeat Indicates the system status of the B450 and its connection to the panel. RX Indicates when an inbound packet is received on the bus. TX Indicates when an outbound packet is transmitted on the bus. Region US NIST FIPS 197 FCC Part 15 Class B UL 365 UL 636 UL 864 1JL985 UL 1023 UL 1076 UL 1610 SIA CP01:2010 False Alarm Reduction California State Fire Marshall (CSFM) -Certified Fire Department of New York (FDNY) - Certified Canada CAN/ULC S303 CAN/ULC S304 ULCS545 ULC-ORD C1023 ULC-ORD C1076 ICES-003 - Digital Apparatus Rogers - Certified North PTCRB - Certified America Europe CE - EN50130-4, EN61000-6-3, EN60950 Australia A-tick - Certified Region Certification Europe CE 2014/30/EU EMC Directive (EMC); 2014/35/EU Low-Voltage Directive (LVD); 2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equip- ment(RoHS) USA CSFM see our website FDNY- #6173 CoA Brazil ANATEL 2708-14-1855 Mounting considerations Find a location with acceptable signal strength on your wireless network. Mount the B450 Conettix Plug-in Communicator Interface into the interior of a compatible enclosure via the 3-hole mounting pattern using the supplied mounting screws. Wiring considerations The B450 connects to a control panel using a data bus connection via the module's terminal strip, or the module's interconnect wiring connectors. For data bus powered installations outside the compatible control panel enclosure, follow the maximum wiring distances in the technical specifications. For further installations power from a compatible auxiliary power supply. Quantity Component 1 B450 Conettix Plug-in Communicator Interface 1 Hardware pack 1 Interconnect cable wiring 1 Quick Start Guide (hardcopy) 08103 0203 1 Literature (mini-CD) Applications Tera Term (for USB B450 configuration) HyperTerminal (for USB B450 configuration) Technical -specifications RPS version 5.16 or higher Electrical Installed Bus Current Standby: 8450 with 13440/1344 1/13442/13443 Function Option/SDI SDI2 - Details (operating) 60 mA Alarm: B450 with B440/B441/B442/B443 = P Event Y V TCP protocols 180 mA Reporting only supported on Voltage (operating) (8450 bus operation): 12 VDC nominal SDI2 Environmental Remote V V Requires Relative humidity Up to 93% at +32°C (+90°F) non-condensing Program (RPS Bosch Cellular or A-link) service or Operating 0°C to +50°C (+32°F to + 122°F) other cellular temperature network access Mechanical Configure N V GV4/13 Series Board dimensions 79 mm x 128 mm x 38 mm (3.11 in x 5.03 in x B450 from v2.03+, AMAX 1.50 in) control panel vX.X, Solution (RPS, A-link) vX.X Wiring Personal N Y Requires Data bus wire 12 AWG to 22 AWG Notification compatible gauge via SMS or control panel Email and cellular USB cable USB cable (Type A to A male-to-male) - not plan supplied Remote N Y. Requires Data bus wire Maximum Distance Security Bosch Cellular length - wire size: Control App service or 22 AWG (0.65 mm) --> 12 m (40 ft) other cellular 18 AWG (1.0 mm) -->30 m (100 ft) network 16 AWG (1.3 mm) -->48m(158ft) access 12 AWG (2.0 mm) --> 122 m (400 ft) Using a separate power supply, such as the Ordering-information t B520 Auxiliary Power Supply Module B450 Conettix Plug-in Communicator Interface connected to the 8450 within the specification Supports two-way I P communication over using a plug- listed above, the wire distance can be extended up to300m(l000ft) in Cellular Communicator for compatible SD12, SDI or option bus control panels. Compatibilities Order number B450 Control panels B5512/B4512/63512 (B5512E/845 12E/ Accessories B3512E with firmware v2.03 and higher) B440 Conettix Plug-in Cellular Communicator 09412GV4/07412GV4/D7212GV4 (vl.00.oxx+) Dual technology 3G EVDO/CDMA cellular 09412GV3/07412GV3/D7212GV3 09412GV2/07412GV2/7212GV2 (v7.06) communicator for secure two-way I P communication FPD-7024(vl.03+) on the Verizon Wireless network. AMAX 2000/2100/3000/4000 Order number B440 CMS 618 CMS 40 B441 Conettix Plug-in Cellular Communicator Solution 2000/3000 Multi-function CDMA cellular communicator for secure Cellular 8440 Conettix Plug-in Communicator, Cellular (3G) two-way IP communication on the Verizon Wireless communicators B441 Conettix Plug-in COMA Cellular network. Communicator Order number B441 B442 Conettix Plug-in GPRS Cellular Communicator B443 Conettix Plug-in HSPA+ Cellular B442 Conettix Plug-in GPRS Cellular Communicator Communicator Multi-function cellular communicator. For use in Latin America. Enclosures 810 Order number B442 Bli 4 I B450 Conettix Plug-in Communicator Interface B443 Conettix Plug-in HSPA+ Cellular Communicator Multi-function 3G/4G cellular communicator providing IP communication over a GSM/GPRS/EDGE/UMTS/ HSPA+ cellular network. For use in Latin America and Canada. Order number B443 Represented by; American: Europe, Middle East, Africa: Asia-Pacific: Chinar America Latina: Bosch Security Systems, Inc. Bosch Security System; B.V. Robert Bosch (SEA) Pie Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Busch Ltda Security Systems Division 130 Perinton Parkway P.O. Boo 80002 Systems 201 Building, No. 333 Fuqoan Road Via Anhanguera, Km 98 Fairport. New York, 14450, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP T5P 13065-900 Phone: -1800 289 0096 Phone: • 3140 2577 284 Singapore 573943 Changning District, Shanghai Campinas. Sao Paulo, Brazil Fax:*1 585 223 9180 Fax: +3140 2577 330 Phone: +69 6571 2808 200339 Chioa Phone: +55 19 2103 2860 tecurity.sates@us.bosch.com nmea.seccritysystems@bos*h.com Fax: +65 6571 2699 Phone +8621 22181111 Fax: *551921032862 www.boschsecurity.us www.bcschsecurity.cnm apr.securitysystems@busch.com Fax: +86 21 22182398 latam.bonciisecurity@bosch.com www.boschsecurity.asia www.koschsecurity.com.co www.bouchsecnrity.com Bosch Security Systems 2014 1 Data subject to change without notice 110361662511 an. V16, 04. Nov 2014 www.boschsecurity.com 0 BOSCH Invented for life Secure Conettix IP communication from compatible Bosch panels to Bosch receivers using Verizon 3G EVDO/CDMA Remote programming and monitoring of compatible Bosch panels Personal SMS message and e-mail notification options Direct configuration from Bosch Remote Programming Software (RPS), eliminating the need for separate configuration Simple LED status information and advanced keypad diagnostics available The cellular communicator enables 3G EVDO and CDMA secure two-way IP communication over the Verizon cellular networks. Typical applications are: Alarm reporting to a central station Remote panel programming through Remote Programming Software Remote monitoring and control through a mobile application Personal notification using SMS The cellular communicator is built for a wide variety of secure commercial and industrial applications. Flexible end-to-end path supervision, 128-bit to 256-bit AES encryption and anti-substitution features make cellular communicator especially suited for use in high security and fire monitoring applications. Developed for the military, CDMA technology offers long service life with resistance to hacking and jamming. The cellular communicator's dual technology radio uses high speed 3G EVDO when available or switches to CDMA if required. Note: Cellular capability requires an appropriate data plan from Bosch. Callout - Description 7 - Remote PC's network connection 2 - Compatible control panel 8 - Remote PC running RPS 3 - Antenna cable 9 - Personal SMS notification 4 - Magnetic base antenna 10— Ethernet connection BOSCH Callout - Description 1 —Cellular communicator 2 I B440-C Conettix Plug-in Cellular Communicator 5 - Base station on wireless 11 -Central montoring station carriers network 6-- IP network cloud 1T1iT4r.1,T. Conettix UP communication via Cellular In addition to the security provided by the network operator, the cellular communicator uses our Conettix IP protocol that supports: Flexible polling intervals Resistance to Denial of Service attacks 128-bit to 256-bit AES encryption with Cypher Block Chaining Anti-replay/anti-substitution keys Easy Installation, troubleshooting, and maintenance No networking expertise required at field site (no firewall or router settings) No PC or special tools required for installation and troubleshooting Service plans and settings managed through RPS Diagnostic LEDs for on-site troubleshooting LED Function Blue (heartbeat) System status indicator Red Unacceptable signal strength Yellow Marginal signal strength 1 Green Good signal strength 2 Green Very good signal strength Remote programming of Bosch control panels The cellular communicator supports secure RPS programming of compatible Bosch control panels. Personal notification and control The cellular communicator supports the Bosch Remote Security Control mobile application and can be configured for SMS personal notification reports to mobile phones or e-mail addresses. Region Certification USA Verizon Open Development Certified Region Certification USA UL UL 365 - Police Station Connected Bur- glar Alarm Units UL UL 636- Holdup Alarm Units and Sys- tems UL UL 864- Standard for Control Units and Accessories for Fire Alarm Systems UL UL 985 - Household Fire Warning Sys- tem Units UL UL 1023- Household Burglar Alarm Sys- tem Units Region Certification UL UL 1076- Proprietary Burglar Alarm Units and Systems UL UL 1610- Central Station Burglar Alarm Units CSFM see our website FCC Part 15 Class B FDNY- 6173 CoA FDNY- 6174 CoA FDNY- 6196 CoA Mounting considerations The module plugs into any compatible control panel, available in a variety of enclosures. Wiring considerations The module connects to any compatible control panel without tools or physical wiring for power. When used with the B450 Conettix Plug-in Communicator Interface, the B450 is wired to the control panel data bus. The cellular module has a screw on SMA antenna connection. Cellular service considerations The module is shipped pre-activated for Bosch Cellular service on the Verizon cellular network. A valid service contract is required prior to ordering. Compatibilities Control panels B9512G/B9512G-E, B8512G/B8512G-E B6512 B6512/B5512/B4512/B3512, B5512E/ B4512E/B3512E control panel with firmware v2.03 or higher (direct insertion) The B440 is compatible with most Bosch control panels when used with a B450 Conettix Plug-in Communicator Interface. Refer to the B450 datasheet for complete control panel compatibility listings. Cellular EVD0 rev A CDMA2000 1xRTT Cellular technology compatibility Device Cellular networks 2G 3G GPRS HSPA+ (CDMA) (CDMA) (GSM) (GSM) B44fY X X 8441* X 8442* X Device Cellular networks 2G 3G GPR$ HSPA+ (CDMA) (CDMA) (GSM) (GSM) B4435 X X 'Check for availability in your region. Quantity Component 1 Cellular module 1 Antenna 1 Literature pack Electrical Current Standby: 35 mA (operating) Alarm: 150 mA Voltage (operating) 12 VDC nominal Radio Verizon CDMA dual band radio 850 MHz and 1900 MHz Environmental - Environment Environmental Class Ill - Indoor Relative humidity 5 - 93% at +32°C (+90°F) non-condensing Operating -10°C to +55°C (+14°F to + 131°F) temperature Mechanical Board dimensions 2 in x 3.68 in x 0.60 in (50 mm x 93.5 mm x 15.25 mm) Antenna (included) Magnetic base omni-directional 8.2ft(2.5 m) cable with SMA connector B440-C Conettix Plug-in Cellular Communicator Dual technology 3G EVDO/CDMA cellular communicator for secure two-way IP communication on the Verizon Wireless network. Activate the module by emailing at: installer.services@us.bosch.com, or by calling Bosch Installer Services (800-289-0096). Order number 6440-C Represented by: E. rope, Middle East, Africa: Bosch Security Systems B.V. P.O. Boo 80002 5600 JO Findhooen. The Netherlands Phone: + 3140 2577 284 emea.securitysystams@bosch.com emea.boschsecurity.com Germany: Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbpjnn Germany www.boschsecurity.com North America: Bosch Security Systems. Inc. 130 Pcrinton Parkway Fairport. New York, 14450, USA Phone: +1800 289 0096 Fan: +15852235180 onlinehelp@us.boschr.nm www.boschsecurity.us Auto-Pacific: Robert Bosch (SEA) Pte Ltd. Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2608 Fax: o65 6571 2699 apr.secaritynystems@bosch.com www.boschsecurity.asla © Bosch Security Systems 2016 Data subject to change without notice 231924a4875 an, V1, 29. Jul 2016 Abm s_ L,.m.., 1i. CD D CD =0>CD CD - 4W (am fl_ -1 Alarm Systems I FMR 7033 LCD - Al I— Ii1L1il ed for1k: Compatible with the FPD-7024 FACP Two-line, 32-character, alphanumeric LCD display Status LEDs identify alarm, trouble, supervisory, and silenced conditions Address setting by jumper Remotely control system commands and programming Passcode protection controls system access Low profile design The FMR-7033 LCD Keypad combines remote annunciator and controller functions for fire alarm systems controlled by the FPD-7024 Fire Alarm Control Panel (FACP). It operates identically to the user interface on the FPD-7024 FACP. You can connect up to four FMR-7033 keypads to an FPD-7024. The FMR-7033 allows remotely starting local system tests, system programming, system control, and viewing the system's event log. Passcode protect access to system functions allowing installation in areas open to the general public. The two-line, 32-character LCD (liquid-crystal display) annunciates system status and events. The top line provides general system status information, while the bottom line identifies specific devices or instructions. An internal sounder signals alarm, supervisory, and trouble conditions and annunciates keystrokes during programming and control procedures. Four status LEDs indicate supervisory, alarm, trouble, and silenced conditions. A pull-out slide with operating instructions fits behind the mounting base. Certifications and Approvals Region Certification USA UL UL864, 9th edition FM CSFM 7165-1615:227 Control Unit (Non High- Rise) FDNY- #6024 CoA Installation/Configuration Notes Compatible Products The following products are compatible with the FMR-7033 LCD Keypad: Category Product ID Product Description Control Panels FPD-7024 FACP Keypads and An- D7030X LED annunciator nunciators D7030X-S2 LED annunciator D7030X-58 LED annunciator Mounting Surface mount or mount the FMR-7033 on a single-gang or four-inch square back box. www.boschsecurity.com Wiring Guidelines Do not share keypad wiring with multiplex, telephone, or notification appliance circuit (NAC) wiring. Use a minimum of 22 AWG (0.8 mm) four-wire cable; do not use twisted pair or shielded cable. Note A minimum of 18 AWG (1.2 mm) cable is needed for NEC-N FPA-72. Do not exceed 1000 ft (305 m) between the control panel and the remote keypads. Do not exceed 4000 ft (1219 m) of keypad wiring per system. Number of keypads Do not connect more than four keypads. Place up to two keypads along any single 1000 ft (305 m) run of 22 AWG (0.8 mm) wire. Three keypads can be used on any single 1000 ft (305 m) run of 18 AWG (1.2 mm) wire. Parts Included Quant. Component 1 LCD keypad 1 Literature pack Technical Specifications Enclosure Design Dimensions (HxWxD): 4.6 in. x 6.3 in. x 1.2 in 12 cm x 16 cm x3 cm) Environmental Considerations Environment: Indoor, dry Relative Humidity: Up to 95%, non-condensing Temperature (Operating): +32°F to + 122°F (0°C to +50°C) Power Requirements (Option Bus) Current (alarm): 100 mA Current (standby): 80 mA Voltage (operating): 12 VDC nominal Ordering Information FMR•7033 LCD Keypad FMR-7033 Combines remote annunciator and controller functions for fire alarm systems controlled by the FPD-7024 Fire Alarm Control Panel Americas: Europe, Middle Eust, Africa: AoioPocifIo: Represented by Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Systems 130 Perinton Parkway P.O. Box 00002 11 Bishan Street 21 Fairport. New York, 14450. USA 5600 JB Eindhoven. The Netherlands Singapore 573943 Phone: 1 800 281 0096 Phone: * 3140 2577 284 Phone: n65 6571 1600 Fax: *1 585 223 9180 Fax: .31 40 2577 330 Fax: 565 6071 2690 secunity.sales@us.bosch.com emea.securitysysterns@bosch.cem apr.securitysystcms@bosch.com www.beschsecarity.us www.boschsecarity.uom www.bnschsecarity.com © Bosch Security Systems Inc. 2009 ( Data subject to change without notice T2394629771 (Cur: en-US. V6, 3 Dec 2009 Fire Alarm Systems I D7044 Multiplex Single-input Module I O BOSCH Invented for life D7044 Multiplex Single-input Module Use with D7024, DS9400M, or FPD-7024 Addressable FACPs Fits into a standard double-gang or four-inch square back box Easy addressing using rotary switches Low current draw UL Listed Fil The D7044 Multiplex Single-input Module connects a normally-open (NO) contact to the multiplex bus of a D7024, DS9400M, or FPD-7024 Addressable Fire Alarm Control Panel (FACP). Use the D7044 supervised input in a Class B configuration. All operating power for the input module is drawn from the FACP. Note D7024 and DS9400M are not listed under UL864, 9th edition. Rotary switches allow convenient address setting. An on-board status LED on the module indicates normal, alarm, and trouble conditions and is visible on the module or on an attractive, low-profile faceplate. Installation/Configuration Notes Compatible Products The following products are compatible with the D7044 Multiplex Single-input Module: www.boschsecurity.com Certifications and Approvals - Region Certification - USA UL AMCX: Central Station Alarm Units (UL1610, UL1635), AOTX: Local Alarm Units (UL464, UL609), APAW: Police Station Alarm Units (UL365, UL464), and NBSX: Household Burglar Alarm System Units (UL1023) UL864, 9th edition FM CSFM 7165-1615: 147 7165-1615:227 NYC-MEA 12-92-E, Vol. 14 Category Product ID Product Description Control 07024 Addressable FACP Panels 07024-EXP Addressable FACP for export DS9400M Addressable FACP FPD-7024 Addressable FACP Modules D7039 Multiplex expansion module Mounting Mount the D7044 on a double-gang or four-inch square back box. Wiring Make connections to the terminals on the rear of the D7044. All terminals can accommodate up to 12 AWG (2.3 mm) wire; however, follow wiring guidelines specified by the National Electrical Code (NFPA-70). All wiring is power limited and supervised. Note Supervise the input loop with the supplied EOL resistor. Parts Included Quant. Component 1 07044 module 1 2.21 kf) end-of-line (EOL) resistor (P/N: 25899) 1 Literature pack 1 Hardware pack I - . Technical Specificatuons. ... -. — Circuit Designation MUX Bus: Supervised Class A (Style 6) SLC or Class B (Style 4) SLC Input: Supervised Class B (Style B) IDC Environmental Considerations Environment: Indoor, dry Relative Humidity: Up to 93% non-condensing Temperature (operating): +32°F to + 120°F (0°C to +49°C) Input Type: One normally-open (NO) contact input supervised by a 2.21 kO EOL resistor (P/N: 25899) Mechanical Properties Color: White Dimensions: 43125 in. (10.9 cm) square by 1.0625 in. (2.7 cm) deep Material: ABS plastic Weight: 3.90z(110g) Power Requirements (supplied from FACP's MUX bus) Current: 0.55 mA Voltage (minimum): 8 V peak (12 VDC nominal) LOrdengInf&i- : D7044 Multiplex Single-input Module D7044 Connects a normally-open (NO) contact to the multiplex bus of a 07024. DS9400M, or FPD-7024 Addressable FACP Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport. New York. 14459. USA Phone: +1600 289 0096 Fax: +1585 223 9180 security.sates@us.bosch.com svww.boschsecurity.us Earope, Middle East, Africa: Bosch Security Systems B.V. P.O. Boo 80002 5600 JB Eindhoven, The Netherlands Phone: • 3140 2577 284 Fax: *31 40 2577 330 emea.securitysystems@bnsch.com www.boschsecuri'y.cnm Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: *65 6571 2600 Fax: *65 6571 2698 apr.securitysystems@bonch.com www.boschsecurity.cnm © Bosch Security Systems Inc. 2009 I Data subject to change without notice T1312426379 I Cur: en-US, VS. 3 Dec 2009 Fire Alarm Systems I D7052 Multiplex Dual-input Module BOSCH Invented for life- D7052 Multiplex Dual-input Module The D7052 Multiplex Dual-input Module connects normally-open (NO) contacts to the multiplex bus of a D7024, DS9400M, or FPD-7024 Addressable Fire Alarm Control Panel (FACP). Use the D7052 for two Class B (Style B) supervised inputs or one Class A (Style D) input. All operating power for the input module is drawn from the FACP. Note The D7024 and DS9400M are not listed under UL864, 9th edition. Rotary switches allow convenient address setting. An on-board status LED on the module indicates normal, alarm, and trouble conditions and is visible on the module or on an attractive, low-profile faceplate. Certifications and Approvals Region Certification USA UL UL864, 9th edition FM CSFM 7165-1615: 147 71651615:227 NYC-MEA 12-92-E, Vol. 14 Use with D7024, DS9400M, or FPD-7024 Addressable FACPs Fits into a standard double-gang or four-inch square back box Easy addressing using rotary switches Low current draw UL Listed 'Instal Iation/Configuration Notes - - Compatible Products The following products are compatible with the D7052 Multiplex Dual-input Module: Category Product ID Product Description Control D7024 Addressable FACP Panels D7024-EXP Addressable FACP for export DS9400M Addressable FACP FPD-7024 Addressable FACP Modules D7039 Multiplex expansion module Mounting Mount the D7052 on a double-gang or fou r-inch square back box. Wiring Make connections to the terminals on the rear of the D7052. All terminals can accommodate up to 12 AWG (2.3 mm) wire; however, follow wiring guidelines specified by the National Electrical Code (NFPA-70). All wiring is power limited and supervised. Note Do not use shielded wire. Note Supervise Class B input loops with the supplied EOL resistors. A Class A loop does not require an EOL resistor. www.boschsecurity.com Parts Included Quant. Component 1 07052 module 2 2.21 kO end-of-line (EOL) resistors (P/N: 25899) 1 Literature pack 1 Hardware pack Technical Specifications Circuit Designation MUX Bus: Supervised Class A (Style 6) SLC or Class B (Style 4) SLC Input: Supervised Class A (Style D) IDC or Class B (Style B) IDC Environmental Considerations Environment: Indoor, dry - Relative Humidity: Up to 93% non-condensing Temperature (operating): +32°F to + 120°F (0°C to +49°C) Inputs Type: Two normally-open (NO) Class B (Style B) contact inputs or one Class A (Style D) contact input supervised by a 2.21 kO EOL resistor (P/N: 25899) Mechanical Properties Color: White Dimensions: 4.3125 in. (10.9 cm) square by 1.0625 in. (2.7 cm) deep Material: ABS plastic Weight: 3.9 oz (110 g) Power Requirements (supplied from FACPs MUX bus) Current: 0.55 mA Voltage (minimum): 8 V peak (12 VDC nominal) Ordering Information D7052 Multiplex Dual-input Module D7052 Connects normally-open (NO) contacts to the multiplex bus of a 07024, DS9400M, or FPD-7024 Addressable FACP Americas; Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone; 11800 280 0096 Fax; *1 585 223 9180 security.salesus.bosch.com www.boschsecurity us Europe, Middle East, Africa; Bosch Security Systems B.V. P.O. Bee 80002 5600 JS Eindh000n, The Netherlands Phone: * 3140 2577 284 Fax: *31 40 2577 330 emea.securitysystnrns@bnscn.com www.boschsecurity.com Asia-Pacific; Represented by Robert Botch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax; *65 6571 2698 apr.socuritysystems®bosch.cow www.boschsecurity.ccm © Bosch Security Systems Inc. 2010 I Data subject to change without notice T1312455947 1 Car: en-US, V6, 4 Jul 2010 Fire Alarm Systems I D7053 Multiplex Input-output Module D7053 Multiplex Input-output Module Use with D7024 Addressable FACPs Fits into a standard double-gang or four-inch square back box Easy addressing using rotary switches Low current draw UL Listed The D7053 Multiplex Input-output Module is a general purpose device that monitors a normally-open (NO), supervised contact device and provides a separately controlled Form C relay output. It is used whenever an NO contact must be connected to the multiplex bus of a D7024 Fire Alarm Control Panel (FACP) and a separately-controlled output relay is desired. The D7053 connects to the multiplex bus in either a Class A or Class B configuration. All operating power for the D7053 module is drawn from the control panel's multiplex bus. Rotary switches allow convenient address setting. An on-board status LED on the module indicates normal, alarm, and trouble conditions and is visible on the module or on an attractive, low-profile faceplate. Parts Included Quant. Component 1 07053 module 2.21 kO end-of-line (EOL) resistor (P/N: 25899) Literature pack Certifications and Approvals Listings and UL UOXX: Control Unit Accessories, System Approvals: (UL864 9th edition) CSFM 7165-0801: 177 Factory Mutual Research Security you can rely on. BOSCH 2 1 D7053 Multiplex Input-output Module Installation/Configuration Notes Compatible Products The following products are compatible with the D7053 Multiplex Input-output Module: Environment: Indoor, dry Radio Frequency No false alarm on critical frequencies in Category Product ID Product Description Interference (RFl) the range from 26 MHz to 950 MHz for Control 07024 Addressable FACP Immunity: field strengths less than 30 V/rn Panels D7024-EXP Addressable FACP for export Relative Humidity: - - Up to 93% non-condensing Modules 07039 Multiplex expansion module Temperature (operating): - - -- - +32°F to +120°F (0°C to +49°C) - - Mounting Mount the D7053 on a double-gang or four-inch square back —w-- Type: One normally-open (NO) Class B input supervised by a box. 2.21 kO EOL resistor Wiring Make connections to the terminals on the rear of the D7053. All terminals can accommodate up to 12 AWG (2.3 mm) wire; Color: White however, follow wiring guidelines specified by the National Dimensions: 4.3 in. (10.9 cm) square by 1.1 in. Electrical Code (NFPA-70). All wiring is power limited and (2.7 cm) deep supervised. Material: ABS plastic Weight: 3.9 oz (110 g) Note: Do not use shielded wire. Supervise the Class B input loop with the supplied EOL resistor. Alarm: Reports alarm and point number to FACP Relay: One set of Form C (NO/C/NC) contacts rated for 120 VAC at 05A, 24 VDC at 1.0 A, resistive loads only Trouble: Reports trouble and point number to FACP Current: ieirrients 0.70 mA Voltage (minimum): 12 VDC nominal (8 V peak minimum) D7053 Multiplex Input-output Module 07053 Americas: Europe, Middle East, Africa: Asia-Pacific: Bosch Security Systems Bosch Security Systems B.V. Bosch Security Systems Pte Ltd BOSCH 130 Penrtton Parkway P.O. Box 80002 38C Jalan Pemimpin Fairport, New York, 14450, USA 5600 JB Erdhoven, The Netherlands Singapore 577180 Phone:+1 585 223 4050 Phone:+31 (0) 40 27 83955 Phone:+65 6319 3450 Fax+ 800 289 0098 Fax:+31 (0) 40 27 86668 Fax:+65 6319 3499 securtty.salus@us.bosch.com emes.securitysystems@boxch.com apr.socuriIysystemsibosch.com httpJ/www.boachsecunty.us http:/Iwww.boschsecunty.com http-J/v.ww.boschsecunty.com Data subject to change without notice I Printed in USA I 50593en-01 19.ian 2006 0/ ~F7 Invented for life manua~ staftns j Easy addressing with rotary switches Low current draw Key-lock reset Replaceable scored acrylic breakrod option Terminal connections ADA compliant UL Listed The FMM-7045 Series Multiplex Manual Stations are UL Listed fire alarm initiating devices that can be connected along with other multiplex devices on the D7039 Multiplex Expansion Module. The FPD-7024 or D7024 Addressable Fire Alarm Control Panel (FACP) supervises the entire multiplex loop, including the FMM-7045 or FMM-7045-D manual stations, for troubles, alarms, and ground fault conditions. Because each manual station occupies only one address on the multiplex bus, it can be addressed for any point within the 9 to 255 range allowed by the multiplex expansion module. These manual stations are generally installed near building exits such as stairways and doors, allowing persons evacuating the building to activate the fire alarm. They have optional scored acrylic breakrods and a pull handle that locks in the activated position, to allow easy identification of alarm activation points. These manual stations are high-quality units constructed entirely of non-toxic materials. They have a low profile and rounded edges to fit most design applications. All components are painted or have plated surfaces to inhibit corrosion. Non-corroding screw terminals are provided for wire connections. They are manufactured in conformance with the standards set forth in the Americans with Disabilities Act (ADA). Functions Alarm Action The single-action FMM-7045 has a white pull-down lever in its center. The dual-action FMM-7045-D has a white push lever above the white pull-down lever in its center. Pulling down the pull-down lever latches it into place and sends an alarm signal to the control panel over the multiplex bus. The pull-down lever cannot be reset unless the correct key is inserted into the manual station's lock and the unit is opened. The latching lever can then be restored to its normal position. Certifications and Approvals Region Certification USA UL UNIU: Boxes, Non-Coded (UL38) CSFM 7150-1615: 122 NYC-MEA 12-92-E, Vol. 14 ADA Complies with Americans with Disabilities Act ADA 4.28.3 NFPA Complies with National Fire Protection Association NFPA 72 www.boschsecurity.com Installation/Configuration Notes Compatibility Information The FMM-7045 Series Multiplex Manual Stations are compatible with a FPD-7024 FACP or a D7024 FACP with firmware revision 2.0 or greater with a D7039 Multiplex Expansion Module. Addressing Addresses are set using three rotary switches. Refer to the 07024 FACP Operation and Installation Guide (P/N: 31499) or the FPD-7024 Operation and Installation Guide (P/N F011J008458) and the FMM-7045, FMM-7045-D Multiplex Addressable Manual Stations Installation Instructions (P/N: F011J001402) for programming information. Mounting The FMM-7045 manual stations are for indoor use only. Note If a pull station is needed for outdoor use or in an unheated area, use an FMM-100 Series Pull Station rated for the environment and wired to a multiplex module within the interior of the building. The FMM-7045 manual stations flush or surface mount on a standard four-inch square back box with a single-gang mud ring so that the total depth of the box is at least 2.25 in. (5.7 cm). Note The FMM-7045 does not fit an FMM-100BB-R Back Box. Wiring The terminal block accepts wiring up to 12 AWG (2.3 mm) in diameter. Refer to the 07039 Installation Instructions (P/N: 38685) for multiplex wiring information. Parts Included Quant. Component 1 Manual station 1 FMM-100GR Scored Acrylic Breakrod 1 D102 Key (1358) 1 Literature pack Technical Specifications Environmental Considerations Environment: - Dry, indoor Radio Frequency No alarm on critical frequencies in the range Interference (RFI) from 26 MHz to 950 MHz at field strengths Immunity: less than 30 V/rn. Temperature (Operating): +32°F to +120°F (0°C to +49°C) Mechanical Properties Dimensions (H x W x 0): 4.75 in. x 3.75 in. x 3.25 in. (12 cm 9.5 cm 8.2 cm) Material: Die cast zinc alloy and steel Power Requirements Current Draw Alarm: 0.55 mA (Mux Bus Average): Standby: 0.55 mA Voltage (Operating): 12 VDC nominal (provided by the MUX bus) Ordering Information FMM-7045 Single-Action Manual Station FMM-7045 A UL Listed fire alarm initiating device that can be connected, along with other multiplex devices: on the 07039 Multiplex Expansion Module and is supervised by the FPD-7024 or 07024 Addressable FACE' FMM-7045-D Double-Action Manual FMM-7045-D Station A UL Listed fire alarm initiating device that can be connected: along with other multiplex devices, on the 07039 Multiplex Expansion Module and is supervised by the FPD-7024 or 07024 Addressable FACE' Accessories D102 Replacement Key D102 Replacement key (#1358) for the 0101 lock. FMM-100GR Scored Acrylic Break Rods FMM-100GR Scored acrylic rods (12 per package) Americas: Bosch Security Systems, Inc. 130 Poninton Parkway Fairport. New York. 14450. USA Phone: *1 BOO 289 0096 Fax: +1585 223 9180 security.sales®usbosch.com wwwboschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5800 JB Eindhoven, The Netherlands Phone: ° 3140 2577 284 Fax: +3140 2577 330 emea.securitysystoms@boscl:.co:o www.bnschsecunty.com Asia-Pacific: Represest.d by Rxbert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +55 6571 2600 Fax: *65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.com © Bosch Security Systems Inc. 2009 I Data subject to change without notice T1953041035 Cur: en-US, VB. 7 Dec 2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1615:0227 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model FPD-7024 fire alarm control unit. Power limited, local, automatic, manual, coded, noncoded, remote station (PPU), proprietary (PPU), central station (PPU), waterfiow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: FPD-7024; Control Unit FPC-7034; 4-Zone Expander FMR-7033, FMR-7036; Keypad D7035, D703513; Expanded Relay Module D185; Reverse Polarity Module D7039, *FPEj039; MUX Expander D7042, 07042B, D7044, D7044M, D7052, D7053; Mulitplez Expander Module D7048, D704813; Octal Driver Module B440, B441, B443; Cellular Modules B450; Interface Module *FLM 7024 ISO MUX Bus Isolator Module RATING: 120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Revsjon 02-15-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This iisting is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 3O,2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 0 l—j— I UJ I HT H Ua Ps.1213 ND DZ(/E17 + A 812IitIiL8IOMHi GtEMEM 7777 Absorbent Glass Mat (AGM) technology for superior performance Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.0.T., I.A.T.A., F.A.A. and C.A.B. certified U.L. recognized under file number MH 20845 IIprmane1SIifi(i mown" S Nominal Voltage ........................................................................ 12 volts (6 cells) Nominal Capacity 20-hr. (900mA to 10.50 volts) .......................................................18.0 AH 10-hr. (1.7A to 10.50 volts) .............................................................17.0 AH 5-hr. (3.2A to 10.20 volts) ............................................................16.0 AH 1-hr. (lilA to 9.00 volts) .............................................................11.1 AH 15-mm. (34.3A to 9.00 volts)..............................................................8.58 AH Approximate Weight ........................................................12.60 lbs. (5.72 kg) Energy Density (20-hr. rate) .................................1.53 w-h/in3 (93.51 W-h/1) Specific Energy (20-hr. rate) ...............................17.14 w-h/Ib (37.79 w-h/kg) Internal Resistance (approx.) ......................................................14 milliohms Max Discharge Current (7 Mm.) ...............................................54.0 amperes Max Short-Duration Discharge Current (10 Sec.)................180.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C)) 1 Month ......................................................................................................97% 3 Months.....................................................................................................91% 6 Months ....................................................................................................83% Operating Temperature Range Charge .. ........................................................... -4°F(-20°C)to 122°F (50°C) Discharge ....................................................... -40°F (-40°C) to 140°F (60°C) Case......................................................................................................ABS Plastic Power-Sonic Chargers .... PSC-122000A, 124000A, 122000A-C, 124000A-C P5-12180 F2: Quick disconnect AMP, INC. Faston tabs, 0.250" x 0.032" PS-12180 NB2: Tin plated brass post with 5mm nut & bolt connectors —7.95-H 14 0 6JJ12 L 7.13 (181) W: 3.00 (76) H: 6.59 (167) HT: 6.59 (167) Tolerances are +1-0.04 in. (+1- 1mm) and /- 0.08 in. (/- 2mm) for height dimensions. All data subject to change without notice. Alasuhang otic - - —ww1powersonicTtom cturprig is rot - necessary tinhs 100%atcapacit - - - - - I - . is required. - _ N 5°C - (41 - F) Charging betas use is necessa to help recover - - - - - - - - " _ may fad to r tot capacity. Donol 40° 30C 20C I - - (104°F) _(860F) _(68°F)-f--- let baltanesreac - this state. 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) !!!ii•IiiIi1I lIII•IIIIP!I IIIIlUI!!i1I111 L1IIIIUIiiUU IIIEIIIUIII•I 14.0 13.0 > 12.0 0) a 11.0 (5 .E 10.0 E 0 I- 9.0 8.0 --- --- --- ... U'MEN kniIuI I NEEMSEE NIEMENI•_ _ T 20 15 10 E I- 2 0) (5 o I 'I) 30 E 10 100 0n 15 0 0 Discharge Depth 100% Discharge Depth 50 Discharge Depth 30% Discharge Current 0.2C (Final Voltage 1.7V/Cell) Charge Current: 0.IC I I Ambient Temperature: 20°C to 25°C (68°F to 77°F) I I I I I I 200 400 600 800 1000 1200 Number of Cycles 120 100 80 Shelf Life & Storage Discharge Characteristics Discharge Time vs. Discharge Current 1.2 2.4 6 12 2436481 2 4 6 810 2040 mm h "I Discharge Time Life Characteristics in Stand-By Use - Ambient Temperature 20C (68F) 1E7 -T --r 2.25 - Charging 2.30 V/Cell Voltage ii III 0 1 2 3 4 (104°F) Years (68°F) (32°F) Life Characteristics in Cyclic Use 0.90 1.8 3.6 9.0 18 36 Discharge Current (A) Cycle AppllcaUons: Limit initial current to 5.4A. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 18OmA. Battery is fully charged under these conditions, and charger should be disconnected or switched to "float" voltage. "Float" or "Stand-By" Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Note: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for "C-Series downloads, such as product catalogs, material safety data sheets (MSDS), ISO Switch Mode Chargers" and "Transformer Type A and F Series". Please contact our certification, etc.. Technical department for advice if you have difficulty in locating suitable models. ContactIInformation 'AVA' .I.1'L'-.] 1[''i.]ii• DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel: +1-619-661-2020 Tel: +1-619-661-2030 Tel: +1-619-661-2020 Tel: +1-650-364-5001 Fax: +1-619-661-3650 Fax: +1-619-661-3648 Fax: +1-619-661-3648 Fax: +1-650-366-3662 national-sales@power-sonic.com customer-service@power-sonic.com support@power-sonic.com btttery@power-sonic.corn CORPORATE OFFICE • 7550 Panasonic Way San Diego, CA 92154 • USA • Tel: +1-619-661-2020 ° Fax: +1-619-661-3650 408 IM CM Ii1L1iI • for 1k: FPPi\1AC8A4C Remote N otification Applliace Circuit (RNAC) Power SuppOy Use the FPP-RNAC-8A-4C power supply to add four additional notification appliance circuits to a fire alarm control panel (when connected via the option bus), or as a NAC power supply for fire-protective signaling systems (when connected directly to the NAC output). The additional notification appliance circuits can be NFPA 72, Class B (Style Y) or Class A (Style Z). This regulated power supply provides up to 8 A of power that is used to operate both continuous and intermittent loads. This 8 A of power can be distributed through the four output circuits and auxiliary power circuit. The FPP-RNAC-8A-4C power supply is UL Listed for use in commercial fire alarm applications. Functions Compatible Control Panel Connections The FPP-RNAC-8A-4C power supply is compatible with any UL Listed control panel that uses reverse polarity supervised notification outputs with 12 VDC or 24 VDC regulated outputs. It is also compatible with the following Bosch Control Panels: D7022 Two-zone Conventional FACP D8024 and D10024A Analog FACPs 8Aof power Fully supervised outputs Configurable for NAC output or constant auxiliary power Regulated 24 VDC output (nominal) with over-current protection Built-in NAC patterns Four Class B (Style Y) or Class A (Style Z) circuits Form C trouble relay Status indicator on control panel when connected to the option bus. Ground fault indication Charger control monitor - For the D7022 conventional panel and the D8024 and D10024A analog panels, the FPP-RNAC-8A-4C connects through a NAC circuit. No option bus connection is necessary. D7024 Four-zone Addressable FACP DS9400i Four-zone FACP DS9400M AddressiFire FACP - Connect up to two FPP-RNAC-8A-4C power supplies to a D7024, DS9400i, or DS9400M Control Panel. The control panel can individually control each of the four NAC outputs for each FPP-RNAC-8A-4C power supply. Only the four NAC outputs of a single FPP-RNAC-8A-4C will be synchronized. FPD-7024 or FPA-1000-UL FACP - Connect up to four FPP-RNAC-8A-4C power supplies to an FPD-7024 or an FPA-1000-UL control panel. Each RNAC's four NAC outputs will be synchronized and can be individually controlled for a total of 16 synchronized circuits. NAC Output Patterns The NAC circuits can be set to produce the following output patterns: Steady Temporal Code 3 Pulsed California March o Wheelock Synch Gentex Synch System Sensor Synch www.boschsecurity.com Temperature (operating): +32°F to + 120°F (0°C to +49°C) Inputs (NAC) Response Time (input to output): 10 ms maximum Mechanical Properties Color: Red Dimensions (HxWxD) 20.4 in. x 14.8 in. x 4.1 in. without door: (52 cm 38 cm x 10.4 cm) Material: cold-rolled steel Base: 18 gauge (1.2 mm) Cover: l9 gauge (1.lmm) Outputs (auxiliary) Current(output): 850 mA maximum Voltage (output): 24 VDC (regulated) Outputs (NAC) Output per circuit: 2.5 A maximum Output (total): 8 A (all NAC and auxiliary outputs) Voltage (output): 24 VDC (regulated) Voltage (standby): -24 VDC (regulated) Outputs (trouble and ac trouble relays) Contact Type: Form C Rating (contact): 1.5 A at 32 VDC 2 I FPP-RNAC-8A-4C Remote Notification Appliance Circuit (RNAC) Power Supply Status Displays There are eight local status display LEDs on the FPP-RNAC-8A-4C's printed circuit board that show the following conditions: AC OK System Trouble Ground Fault Input Active Trouble Output 1, 2, 3, and 4 DIP Switch Settings If connected to the fire alarm control panel's option bus, the FPP-RNAC-8A-4C needs its own option bus address. Set this address through the DIP switches. Set the DIP switches to choose: NAC or power supply output NAC Input Variable option AC Delay Time UC rtificationsandAppróvals Category Product ID Product Description Four-wire Smoke Detectors Refer to Technogram (P/N: F01U010790) NAC Devices Refer to Technogram (P/N: F01U010791) Wiring All wiring is connected to the power supply board by lift-gate terminals that can accept up to 12 AWG (2.3 mm) wire. Parts Included Quant. Component 1 FPP-RNAC-8A-4C board 1 AE4 Large Enclosure (red), vented 4 2.21 kO end-of-line (EOL) resistors (P/N: F01U034504) For retrofitting applications, allowable EOL values are in the range ofik!) to 20 kO 1 Hardware pack Region - Certification - - USA UL UOXX: Control Unit Accessories, System icalspecifications (ANSI/UL 864, 9th edition) and UTRZ: Power-supply Units (UL 1481) Environmental Considerations FM CSFM 7300-1615:228 FDNY- #6024 CoA fflstaUaon/ConfiguratnNotes ' Compatible Products The following products are compatible with the FPP-RNAC-8A-4C RNAC Power Supply: Category Product ID Product Description Batteries D126 12 V, 7 Ah battery D1218 12V, 18 An battery D1224" 12V, 24 Ah battery D1238" 12 V, 38 Ah battery Up to two 18 Ah batteries fit in the enclosure "Requires BATB-40 Battery Box Magnetic Door Holders D3708 Brass-Plated Wall-Mount D370C Chrome-Plated Wall-Mount D37 1B Brass-Plated Floor-Mount D37 1C Chrome-Plated Floor-Mount Power Requirements Current (input): 4.5 A maximum (RMS) Power (primary input): 120 VAC, 60 Hz or 220 VAC, 50 Hz Voltage (battery): 24 VDC nominal Ordering Information FPP-RNAC-8A-4C Remote Notification FPP-RNAC•8A-4C Appliance Circuit (RNAC) Power Supply Adds four additional notification appliance cir- cuits to a fire alarm control panel Accessories D102 Replacement Key D102 Replacement key (#1358) for the 0101 lock. www.boschsecurity.com 4 I FPP-RNAC-8A-40 Remote Notification Appliance Circuit (RNAC) Power Supply Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone +1800 289 0096 Fax: +1 585 223 9180 security.sales®us.bosch.com www.boschsecurity.us Europe, Middle East, Africa Bosch Security Systems B.V. P.O. Box 80002 1600 JB Eindhoven, The Netherlands Phone: n 3140 2577 284 Fax: .31 41 2577 330 omoo.securitysystems@bosch.com www.boachsecurity.com Asia.Paciftw Represnoted by Robert Busch (SEA) Pie Ltd, Security Systems 38C Jalan Pern:mpin Singapore 577180 Phone: *65 6319 3453 Fax: *65 6319 3499 apr.sxcurityxystews®hosch.com www.bouchsecwity.com Bosch Security Systems inc. 2009 I Data subject In change without notice T2727277451 I Car: en-US, V4, 16 Jul 2009 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1615:0228 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolskius.bosch.com DESIGN: Model FPP-RNAC-8A-4C Remote NAC Power Supply. The FPP-RNAC-8A-4C is a Remote Notification Appliance Circuit (NAC) Power Supply/Expander. The device connects to the Option Bus of the D7024, FPD-7024 or FPA-1000 Fire Alarm Control Panel (FACP) and is designed to add four additional NAC Circuits and an Auxiliary Output to the system. Refer to listee's data sheet for detailed product description. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, and UL label. APPROVAL: Listed as a remote NAC Power supply for use with listee's separately listed alarm control units. 03-05-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not ®rvz an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Absorbent Glass Mt (AGM) technology for superior - .. performance • Valve regulated, spill proof construction allows sale operation in any position 14. • Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) c. ,c Anrim,prI frr trnnrinrt hv nir fl fl T I A TA PA A nd Nominal Voltage ..... ................................................................... 12 volts (6 cells) Nominal Capacity 20-hr. (350mA tD 10.50 volts) ........................................................7.00 AH 10-hr. (650mAto 10.50 'volts) .......................................................6.50 AN 5-hr. (1.2A to 10.20 volts) ..... ....................................................... 6.00AH 1-hr. (4.5A to 9.00 volta) ....... ....................................................... 4.SOAH 15-mm. (14A to 9.00 volts) .................................................................3.50 AN Approximate Weight ...........................................................4.80 lbs. (2.18 kg) Evergy Density (20-h r. rate) J......... ....................... 1.49 W-h/in3 (90.95 WI-h/1) Specific Energy 20-hr. rate ..............................17.50 W-h/Ib (38.58 W-h/kg) Internal Resistance (approx.) ......................................................23 miiliohms Mx Discharge Current (7 Ain.) ...............................................21.0 amperes Max Short.Duiitlon Discharge Current (10 Sec.)..................70.0 amperes Slelf Life (% of nominal capcity at 68°F (20°C)) Month......................................................................................................97% 3 Months......................................... 91% 6 Months .................................... 1 '1...............................................................83% Operating Temperature Range Charge .. ............................ . .......... ..................... -4"F(-20°C)to 122°F( 50°C) Dischrge .......................... ........... ................... 40°F(40°C)to 140°F(60°C) Case ........................................ . ............................................................... ABS Plastic Power-Sonic Chargers ...... ........... ............................... PSC-12800A, 12800A-C I ' I C.A.B. certified :; • U.L. recognized under file number MH 20845 Fl- Quick disconnect tabs, 0.187" x 0.032' - Mate with AMP. INC. Ft F2 FASTON '187" series p3.24, i-a4-i —OR— 4.75 6.35 F2 - Quick disconnect labs, 0.250" x 0.032' •-"n.e '_'0.8 -Mate'with AMP. INC FASTON "250" series 1 J @ w 0 ffl fl' - -:° HT H MOOCt. P5-1270,, W:2.56 (65)H:3:7O Tolerances are /- 0.04 in. (+1- imm) and +/- 0.08 in. +/- 2mm) for heiZht dimensions. All data subject to change without notice. Shelf Life & Storage __!!nMM'"0q 10 !!! Imams I ii!IiIIi P" 0111 milli I.mH-uu-.II. 0 U - - -. - - - 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) 8.0 -r - - - ' char9Isrct necessay unios 100% ci capadt - -_ - - Is required. - - - - - - (41 - F) r Use s0008ssa) . toltalpr000ver - full capacity. - - ChaWrneyfail torestorefull a capacity. Donot 40°C :- 3 C -- -- -F - 20°C - (104°F). .(68°F es teibreac - 1_I )4........ L .....(86 I °F) this stiite. °. 100 0 to 80 C 0 I:; 0. 13.0 1.2 2.4 6 12 24 36481 2 4 6 810 20 40 -'i min h Discharge Time Life Characteristics in Stand-By Use - Ambient Temperature 20C (68'F) --7 Float 2.25 - ______ Charging Voltage 2.30 V/Cell II [H ill 0 1 2 3 4 Years Life Characteristics in Cyclic Use 100 1:: 4° 20 S n 120 10C 80 U 00 60 0 C 2 40 C 20 0 --- --- --- ---- -- - 0 200 400 600 800 1000 1200 Number of Cycles Discharge Toischarge I Discharge Depth 100% Depth 50 Depth 30% - 1. Discharge Current 0.2C (Final Voltage 1.7V(Cell) -2. Charge Current: 0.IC I I 3. Ambient Temperature: 20°C to 26°C (68°F to 77°F) I I I I I - Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certification, etc.. Discharge Time vs. Discharge Current --- __ --- u_ 10,34 MEN le ii.kq'I'ME U &NN 111101 IN_01I.._ E - Ia 0.35 0.70 1.4 3.5 7.0 14 Discharge Current (A) Cycle Applications: Limit initial current to 2.IA. Charge until battery voltage (under charge) reaches 14!4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 70mA. Battery is fully charged under these conditions, and charger should be disconnected or switched to "float' voltage. "Float" or "Stand-By" Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Noe: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. E' Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to the Charger Selection Guide in our specification sheets for "C-Series Switch Mode Chargers' and °Transfermer Type Aand F Series'. Please contact our Technical department for advice if you have difficulty in locating suitable models. DOMESTICSALES I CUSTOMERSERViICE TECHNICAL SUPPORT I INTERNATIONAL SALES I Tel: +1-619-661-2020 Tel: +1.619-661-2030 I Tel: +1-619-661-2020 Tel: +1-650-364-5001 Fax: +1-619-661-3650 } Fax: +1-619-661-3648 Fax: -1-619-661-3648 Fax: +1-650-366-3662 L_nationai-sales@p er-sdnic.com J_ customer-service@powe-sonic.com [_ support@power-sonic.Com CORPORATE OFFICE • 7550 Panasonic Way San Diego, CA 92154 • USA • Tel: +1-619-661-2020 • Fax: +1-619-661-3650 02,11 IM 02011. P-,-Sonic Creporeeon.A5 ,Itt,to reserved. SI Oede,ee,k, e,e Sc prew,ty 01 their respective 20 15 10 a E 2 Cs to U I In 30 E 1 10 (104° F) (68°F) (32°F) 6,:- SYSTEM SENSOR Selectable-Output Horns, Strobes, and Horn Strobes SpectrAlert Advance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units: 15,15/75, 30,75,95,110,115,135,150,177,and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MDL sync module The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGPIAUNG LISTED APPROVED 1101 /(hrnt'S, horn strobes, horns) 3023572 5S5I2 strobes) IMEA approve d 7125-1653 lOS ),ndoor suobnst /125-1653185 Shorn strobes, MFA452-05-f chime strobes) 7135-1653189 (hort's, drones) SpectrAlert Advance Dimensions 5. CD d 6' Wall-mount horn strobes Ceiling-mount horn strobes Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Wall Horn Strobes Ceiling Strobes P2Rt 2-Wire Horn Strobe, Standard cd*, Red SCR Strobe, Standard cd, Red P2RH 2-Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red P2WC 2-Wire Horn Strobe, Standard cd, White SCWC Strobe, Standard cd, White P2WH 2-Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White P4R° 4-Wire Horn Strobe, Standard cd, Red Horns P4RH 4-Wire Horn Strobe, High cd, Red HR Horn, Red P4W 4-Wire Horn Strobe, Standard cd, White HW Horn, White Wall Strobes Accessories SR°5 Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red SRH°5 Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall, White SW° Strobe, Standard cd, White BBSC-2 Back Box Skirt, Ceiling, Red SWH° Strobe, High cd, White BBSCW-2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes TR-HS Trim Ring, Wall, Red PC2R 2-Wire Horn Strobe, Standard cd, Red TRW-HS Trim Ring, Wall White PC2RH 2-Wire Horn Strobe, High cd, Red TRC-HS Trim Ring, Ceiling, Red PC2W°t 2-Wire Horn Strobe, Standard cd, White TRCW-l-IS Trim Ring, Ceiling, White PC2WH° 2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd,White Notes: Add -P10 model number for plain housing (noFlREmarking on Cover), e.g., P211-P t Add -SP to model number foFUEGOmarkirig on cover. e.g., P2R-SP. rstandard cdrefers to strobes that include 15,15/75,30,75,95, 110, and 115 candela settings. High cd'refers to strobes that include 135, 150,177, and 185 candela settings. 5"S7EII_,1 2OO9 5yscenr Sensor 3825 Ohio Avenue. Sr. Charles, IL 60174 5 ftJ5 Phone: 800SENSOR2 . Fax: 630-377-6495 UL Current Draw Data tIJ Strobe Current IDraw T1(mAT1 h'I.1 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 17/ NA NA 281 251 UL Max. Current Draw (mA DC Input RMS), 2-Wire Horn 8-17.5 Volts 15 Strobe, 15/75 Standard Candela 16-33 Volts 15 Range 15/75 (15-11 S cd) 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 66 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low IIJ CurrentDraw (mA DC Input 132 154 RMS), 2-Wire Horn Strobe, 16-33 Volts 135 150 80 177 High Candela 185 90 Range 105 161 (1135-185 cd) FWR Input 184 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal 1-ugh 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC FWR DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 /5 81 81 88 84 96 92 71 Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 711 85 85 90 90 97 98 Coded Low 75 75 81 81 88 85 96 92 Settings 7. 8, arid 9 are not available on 2-wire horn strobe. A05-3395-A01 SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or lull-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30, 75,95,110, 115, 135, 150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 l-Iz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern.These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4/16 x 41 V16 21/8-inch back box.The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DCJFWR or regulated 24 DC/FWR' Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18AWG Ceiling-Mount Dimensions (including lens) 6.8 diameter x 2.5 high (173 mm diameter x 64 mm high) Wall-Mount Dimensions (including lens) 5.6 Lx 4.7-W x 2.5 D (142 mm Lx 119 mm x 64mm D) Horn Dimensions 5.6Lx4.7-Wx 1.3D(142 mm Lx 119mmWx 33 mm D) Wall-Mount Back Box Skirt Dimensions (885-2, BBSW-2) 5.9-L x 5.0W x 2.2 D (151 mm Lx 128 mmW x 56 mm D) Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1- diameter x 2.2-high (180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS, TRW-HS) 5.1 Lx 4.8W x 0.35'D (145 mm Lx 122 mm W x 9 m D) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, TRCW-HS) 6.9 diameter x 0.35 high (175 mm diameter x 9 m high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-A95-U07 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes" four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as °horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes" can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CAS TILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL ij77 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0186 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: VIadimir.KireyevhoneyweIl.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15, 15/75, 30, 75, 95, 110, 115, *135 *150 *177 *185cc1 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. Rev. 03-11-10fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division II[OFrnT(yAVNL(III GENESIS SERIES • Description: 14 AWG 2/C SOL FPLP-CL2P Compliance: UL Standards 13 & 1424; NEC Articles 725 & 760 Construction: Conductor 14 AWG Solid Bare Copper No. of Conductors 2 Insulation Type Plenum PVC Color Blk, Red Thickness 0.007" nom. Diameter 0.078" nom. Lay Length 3.0" nom. Jacket Type Plenum PVC Color Red Thickness 0.015" nom. Diameter 0.180" nom. Legend (Ink Print) HONEYWELL P/N 4513 2C14 3038058 (ETL) FPLP OR CUP C(ETL)US FT6 75C (RoHS) W/O# XXXXXX-XXXXXX XXXXFT DEVICE/ZONE A B C D E F 12 3 4 5 6 789 Properties: Temperature Rating -20 to 75°C Operating Voltage 300 Volts max. Capacitance 32 pf/ft nom. Impedance 59 Ohms nom. DC Resistance 2.5 Ohms/M' at 20°C Flame Rating UL 910, NFPA 262, C(UL) FT6 REV A 09/01/10 OA HruaflepueL,10 GENESIS SERIES CABLE L' 2 - tILi Description: 18 AWG 2/C SOL FPLP Compliance: UL Standard 1424; NEC Article 760 Construction: Conductor 18 AWG Solid Bare Copper No. of Conductors 2 Assembly Tubed jacket over twisted insulated conductors Insulation Type Plenum PVC Color Bik, Red Thickness 0.007" nom. Diameter 0.054" nom. Lay Length 1.75" nom. Jacket Type Plenum PVC Color Red Thickness 0.015" nom. Diameter 0.134" nom. Legend (Ink Print) HONEYWELL 18 AWG 2/C (ETL) FPLPICL2P 3038058 75C WIO# XXXXXX-XXX C(ETL) FT6 XXXXFT DEVICE/ZONE ABCDEFI23456789 Properties Temperature Rating -20 to 75 °C Operating Voltage 300 Volts max. Capacitance 24 pf/ft nom. Impedance 65 Ohms nom. DC Resistance 6.5 Ohms/M' at 20°C Flame Rating UL 910, CSA FT6 Construction: Conductor 18 AWG Solid Bare Copper No. of Conductors 4 Assembly Tubed jacket over untwisted insulated conductors Insulation Type Plenum PVC Color BIk, Red, Ylw, Gm Thickness 0.007' nom. Diameter 0.054" nom" Lay Length Straight Jacket Type Plenum PVC Color Red Thickness 0.015" nom. Diameter 0.156" nom. Legend (Ink Print) HONEYWELL 18 AWG 4/C (ETL) FPLP/CL2P 3038058 75C WIO# XXXXXX-XXX C(ETL) FT6 XXXXFT DEVICEZONE ABC DEFI2 3456 789 Properties Temperature Rating -20 to 75 °C Operating Voltage 300 Volts max. Capacitance 24 pf/ft nom. Impedance 65 Ohms nom, DC Resistance 6.5 Ohms/M' at 20°C Flame Rating UL 910, CSA FT6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7161-1487:0100 Page 1 of 1 CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: GENESIS CABLE SYSTEM7701 95TH Street, Pleasant Prairie, WI 53158 Contact: Orville Allen (262) 947-0720 Fax (262) 947-0724 Email: orville@genesiscable.com DESIGN: Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-150, Foam PP, HDPE or LDPE Assembly: 2 to 12 insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gitto/Global Corp., Grade GA-91-84, GPT-45, GA5033, GA93016 Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, NEC Article 760, and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, Type "FPL" and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. Rev. 06-18-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results arid/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division