Loading...
HomeMy WebLinkAbout2628 GATEWAY RD; 135; FPC2019-0151; PermitCCity of PERMIT REPORT Carlsbad Print Date: 10/18/2021 Permit No: FPC2019-0151 Job Address: 2628 GATEWAY RD, # 135, CARLSBAD, CA 92009-1777 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2132621900 Track #: Applied: 07/02/2019 Valuation: $135,605.00 Lot #: Issued: 11/25/2019 Occupancy Group: Project #: Finaled Close Out: 05/25/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: EBULLITION BREW WORKS -SPRINKLER MONITORING FPContractor: RIVER FIRE AND SECURITY INC 8920 ACTIVITY RD, U STE SAN DIEGO, CA 92126-4458 (858) 752-6250 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov SUBMITAL BOOK FOR: EBULLITION 2628 GATEWAY RD STE. 105 CARLSBAD CA 92009 RIVER FIRE AND SECURITY 8920 ACTIVITY RD. STE. J SAN DIEGO CA 92126 C 1 896646 CUTSHEETS AND CSFM LISTINGS FOR: INPUT MODULES - -- -------___ FPC20I9-0151 2628 GATEWAY RD #135 EBULLITION BREW WORKS - SPRINKLER MONITORING 2132621900 7/2/2019 FPC20I9-0151 j 5/31/19 SILENT TFarenhyt KNIGHT by Honeywell IDP-Minimon Agency Listings The IDP-Minimon is a compact and light weight addressable monitor module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Minimon acts as an interface to contact devices, such as waterilow switches and pull stations. The IDP-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features Single contact monitor Small and lightweight size allows for flexible mounting options Support for Class B wiring Fully supervised Rotary address switches for fast installation Analog communications UL Listed Installation The IDP-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. IDP-Minimon Compatibility The IDP-Minimon is compatible with the following FACPs: IFP-2000 I RPS-2000 Intelligent Fire Panel IFP-2000ECS Emergency Communication System with Fire Panel IFP-1000 / ECS Intelligent Fire Panel IFP-100 I ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel P/N 350279 Rev G Copyright© 2015 Honeywell International Inc CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION DPW OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY7550 Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models lDP-Relay-6, SK-Relay-6, relay module, lDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, lDP-Zone-6, SK-Zone-6 six zone interface module, lDP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, lDP-Control, IDP-Relay, SK-Control, SK-Relay, control modules, lDP-Monitor-2, SK-Monitor-2, dual monitor modules,and IDP-RELAYMON-2, *SKRELAYMON2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions andfor other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division