HomeMy WebLinkAbout2656 GATEWAY RD; 140; FPC2018-0403; Permit( PERMIT REPORT ity of Carlsbad Print Date: 10/18/2021 Permit No: FPC2018-0403 Job Address: 2656 GATEWAY RD, # 140, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132622100 Track #: Applied: 12/12/2018 Valuation: $113,260.00 Lot #: Issued: 12/20/2018 Occupancy Group: Project #: Finaled Close Out: 05/26/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: RICHARD WALKER'S PANCAKE HOUSE -REVISED PLANS FOR SPRINKLER TI (32 HEADS) FPContractor: BRIAN SULLIVAN 1975 SPANISH OAK WAY VISTA, CA 92081-7383 (760) 716-9226 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads $553.00 FIRE Plan Resub (3rd&Subsequent Submittal/hr) $136.00 Total Fees: $689.00 Total Payments To Date: $689.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Sully Fire Protection 1975 Spanish Oak Way Vista, California C16 701590 HYDRAULIC CALCULATIONS FOR New Horizontal Sidewall Sprinklers for Tenant Improvement of Exterior Dining Area Richard Walker's Pancake House The Square @ Bresi Ranch Carlsbad, California 92009 0 ( iIoP.i€.." ogJ P4%1IS7 4ij4,ç FILE NAME: Pancake-HSW-REVI.sdf DATE: 22,2019 -Design Data- OCCUPANCY CLASSIFICATION: Light Hazard DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS FLOWING: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE REQUIRED AT SOURCE: PRESSURE AVAILABLE AT SOURCE: SPRINKLER ORIFICE SIZE: 0.10 gpm/1'2 Exterior Dining Area ± 786 ft' 290 ft2 maximum coverage for Sidewalls 5 Horizontal Sidewall Sprinklers 146.7 gpm 246.7 gpm 146.7 gpm @ 44.0 psi 73.4 psi 5.6 Notes: Hydraulic design label for existing system indicated 81.588 psi required at a flow of 479.75 gpm at the base of the riser. These calculations were performed with a source point at the base of the riser, and those values reduced by 10%. 91 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 2/22/2019 C:\HASS FILES\PANCAKE-HSW-REV1.SDF JOB TITLE: Pancake - Sidewalls WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 73.4 73.3 479.8 73.4 247.0 44.0 Available pressure is 29.4 psi (40%) greater than required pressure. AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 247.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 147.0 GPM DENSITY NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE AREA REQ. ACT. (FT) (PSI) (GPM) (FT2) (GPM/FT2) 1 13.0 K= 5.60 27.4 29.3 290.0 0.100 0.101 1A 13.0 - - - - 32.4 --- 2 13.0 K= 5.60 26.8 29.0 290.0 0.100 0.100 2A 11.5 - - - - 32.4 --- 3 13.0 K= 5.60 27.6 29.4 290.0 0.100 0.101 4 13.0 K= 5.60 27.2 29.2 290.0 0.100 0.101 4A 13.0 - - - - 29.2 --- 5 13.0 - - - - 27.2 --- 6 13.0 K= 5.60 28.8 30.1 290.0 0.100 0.104 A 11.5 - - - - 37.0 - - - B 11.5 - - - - 37.1 - - - C 11.5 - - - - 32.4 - - - D 11.5 - - - - 32.2 - - - E 11.5 - - - - 32.3 - - - F 11.5 - - - - 33.1 - - - G 11.5 - - - - 33.2 - - - H 11.5 - - - - 37.7 - - - TOR 11.5 - - - - 38.3 - - - SOURCE 0.0 SOURCE 44.0 147.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 2/22/2019 C:\HASS FILES\PANCAKE-HSW-REV1.SDF JOB TITLE: Pancake - Sidewalls PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -29.3 1.049 PL 10.00 PF 5.0 1 13.0 5.6 27.4 29.3 10.9 120 FTG 2ET PE 0.0 1A 13.0 0.0 32.4 0.0 0.264 TL 19.00 PV Pipe: 2 -29.0 1.049 PL 10.00 PF 4.9 2 13.0 5.6 26.8 29.0 10.8 120 FTG 2ET PE 0.6 2A 11.5 0.0 32.4 0.0 0.259 TL 19.00 PV Pipe: 3 -29.4 1.049 PL 6.00 PF 4.0 3 13.0 5.6 27.6 29.4 10.9 120 FTG 2ET PE 0.6 D 11.5 0.0 32.2 0.0 0.265 TL 15.00 PV Pipe: 4 -29.2 1.049 PL 0.50 PF 2.0 4 13.0 5.6 27.2 29.2 10.8 120 FTG ET PE 0.0 4A 13.0 0.0 29.2 0.0 0.262 TL 7.50 PV Pipe: 5 0.0 1.049 PL 13.00 PF 0.0 5 13.0 0.0 27.2 0.0 0.0 120 FTG ---- PE 0.0 4 13.0 5.6 27.2 29.2 0.000 TL 13.00 PV Pipe: 5A -29.2 1.049 PL 2.50 PF 2.5 4A 13.0 0.0 29.2 0.0 10.8 120 FTG ET PE 0.6 E 11.5 0.0 32.3 0.0 0.262 TL 9.50 PV Pipe: 6 -30.1 1.049 PL 4.00 PF 3.6 6 13.0 5.6 28.8 30.1 11.2 120 FTG 2ET PE 0.6 F 11.5 0.0 33.1 0.0 0.277 TL 13.00 PV Pipe: 7 69.6 1.610 PL 16.00 PF 3.9 A 11.5 0.0 37.0 0.0 11.0 120 FTG T PE -0.6 1A 13.0 0.0 32.4 0.0 0.162 TL 24.00 PV Pipe: 8 40.3 1.610 FL 11.50 PF 0.7 1A 13.0 0.0 32.4 0.0 6.4 120 FTG ---- PE 0.6 2A 11.5 0.0 32.4 0.0 0.059 TL 11.50 PV Pipe: 8A 11.3 1.610 PL 4.40 PF 0.0 2A 11.5 0.0 32.4 0.0 1.8 120 FTG ---- PE 0.0 C 11.5 0.0 32.4 0.0 0.006 TL 4.40 PV Pipe: 8B 11.3 1.610 FL 15.00 PF 0.2 C 11.5 0.0 32.4 0.0 1.8 120 FTG ET FE 0.0 D 11.5 0.0 32.2 0.0 0.006 TL 27.00 PV Pipe: 9 -18.1 1.610 FL 8.00 PF 0.1 D 11.5 0.0 32.2 0.0 2.9 120 FTG ---- PE 0.0 E 11.5 0.0 32.3 0.0 0.013 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 2/22/2019 C:\HASS FILES\PANCAKE-HSM-REV1.SDF JOB TITLE: Pancake - Sidewalls PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 10 -47.3 1.610 PL 5.50 PF 0.8 E 11.5 0.0 32.3 0.0 7.5 120 FTG E PE 0.0 F 11.5 0.0 33.1 0.0 0.079 TL 9.50 PV Pipe: 11 -77.4 1.610 PL 0.75 PF 0.1 F 11.5 0.0 33.1 0.0 12.2 120 FTG ---- PE 0.0 G 11.5 0.0 33.2 0.0 0.197 TL 0.75 PV Pipe: 12 -77.4 1.610 PL 14.50 PF 4.4 G 11.5 0.0 33.2 0.0 12.2 120 FTG T PE 0.0 H 11.5 0.0 37.7 0.0 0.197 TL 22.50 PV Pipe: 13 -69.6 3.068 PL 11.50 PF 0.2 A 11.5 0.0 37.0 0.0 3.0 120 FTG T PE 0.0 B 11.5 0.0 37.1 0.0 0.007 TL 26.50 PV Pipe: 14 -69.6 3.068 PL 58.00 PF 0.5 B 11.5 0.0 37.1 0.0 3.0 120 FTG T PE 0.0 H 11.5 0.0 37.7 0.0 0.007 TL 73.00 PV Pipe: 14A -147.0 3.068 PL 9.00 PF 0.6 H 11.5 0.0 37.7 0.0 6.4 120 FTG 2E PE 0.0 TOR 11.5 0.0 38.3 0.0 0.028 TL 23.00 PV Pipe: 15 -147.0 3.260 PL 11.50 PF 0.7 TOR 11.5 0.0 38.3 0.0 5.7 120 FTG CG PE 5.0 SOURCE 0.0 SRCE 44.0 (N/A) 0.021 TL 34.50 PV NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 50110279 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.100 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.2 ft/sec at pipe 11. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 2/22/2019 C:\HASS FILES\PANCAKE-HSW-REV1.SDF JOB TITLE: Pancake - Sidewalls Available pressure at source node SOURCE under full flow conditions is 73.36 psi with a flow of 296.48 gpm. PIPE FITTINGS TABLE User Pipe Table Name: KEN CUSTOM.PIP PAGE: A MATERIAL: 40 HMC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell T LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv BlHdTe R K -------------------------------------------------------- TeeRun TeeRun 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 2.00 2.00 1.610 4.00 8.00 1.00 9.00 6.00 1.00 10.00 10.00 8.00 3.00 3.00 3.068 7.00 15.00 3.00 16.00 10.00 1.00 13.00 10.00 15.00 0.00 0.00 PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D R Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv TeeRn 3.260 6.70 17.50 7.00 22.00 13.00 1.00 18.00 13.00 0.00 E Co N SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 2/22/2019 C:\HASS FILES\PANCAKE-HSM-REV1.SDF JOB TITLE: Pancake - Sidewalls a) 0 0 U) U) a) 4JC U)4J a)ra 4J0 U) ..-a)4) E-0 0(D 44 ro a)a) _) eU) a) 0U) a)0 zoo 'cz -a) 4) U) a) Q) Q) 0 U) .a) U) U) U) a) a) c 0.. a) .04J a) •H OU) U) 0 0 a) 0 z III N 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N (0 1fl N ,-4 0 -0U)-1-- SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 2/22/2019 C:\HASS FILES\PANCAKE-HSW-REV1.SDF JOB TITLE: Pancake - Sidewalls WATER SUPPLY CURVE 84+ 77+ *\\\\Q\\\\\\\\\\\* <-73.3 psi 8 480 gpm Flow Test Point 70+ 63+ P 56+ R I E I S S 49+ U I R I E I X 42+ P I S I I 35+ 28+ 21+ 14+ LEGEND I X = Required Water Supply I 44.00 psi 0 247.0 gpm 7+ I 0 = Available Water Supply I 73.37 psi 0 247.0 gpm 0++-+---+----+-----+ ------+ --------+ --------+ ---------+ -----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) it, ' tqca Worldwide www.tyco-fire.com Contacts Series TYFRB - 5,6 and 8,0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description TYCO Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Hori- zontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) are decorative 3 mm glass bulb type spray sprinklers designed for use in hydrau- lically calculated sprinkler systems in light hazard, commercial occupancies such as churches, restaurant seating areas, hotels, educational facilities, offices, etc. With their coverage up to 16 ft (4,9 m) wide by 24 ft (7,3 m) long, they are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Hori- zontal sidewall (HSW) sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable. The fast response thermal sensitivity rating of the Series TY-FRB, 3 mm bulb type sprinklers provides for a quick response extended coverage (QREC) rating for many of the coverage areas detailed in Tables B and C. The recessed version of the Series TY-FRB Extended Coverage Horizontal Sidewall Sprinkler utilizes either a two- piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutch- eon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush side- IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 wall position, or a two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Recessed Escutcheon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush sidewall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe lengths to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. EMM The Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. AUGUST 2018 Sprinkler Identification Numbers (SINs) TY333 .EC HSW, 5.6K, 1/2 in. NPT TY4332 ... EC HSW, 8.0K, 3/4 in. NPT TFP296 TFP296 Page 2 of 8 Components DEFLECT( 1 - Frame HAT 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector* 7 - Ejection Spring 6* * Temperature rating is indicated on Deflector or adjacent to orifice WRENCH seat on Frame. 7 FLATS 1/20** NPT 7/16" (11,1 mm) 4/ CENTERLINE 7/16 (39,7 mm) OF SPRINKLER I WATERWAY (11,1 mm) NOMINAL MAKE-IN 1-1/2 I ** Pipe thread connections per i ISO 7-1 can be provided on (38,1 mmiH special request. 7/16 2-3/16 (55,6 mm) (11,1 mm) FIGURE 1 SERIES TV-FRB (TY3332) EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER 5.6K-FACTOR, 1/2 INCH NPT 6* * Temperature rating is Indicated on Deflector or adjacent to orifice WRENCH cant ,n Frame 7 FLATS 3/4" ** NPT ......iI 7/16" (11,1 mm) ri 1-1/2° CENTERLINE I Th38,1 mm) OF SPRINKLER ( WATERWAY 12,7 mm) NOMINAL ** MAKE-IN Pipe thread connections per I 1-1/2' ISO 7-1 can be provided on (381 mm) special request. 9/16" • 2-1/4" (14,3 mmi (57,2 mm) FIGURE 2 SERIES TY-FRB (TV4332) EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER 8.0 K-FACTOR, 314 INCH NPT Components DEFLECT( 1 - Frame HAT 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector* 7 - Ejection Spring Technical Data Approvals UL and C-UL Listed FM and NYC Approved (Refer to Table A for complete approval infor- mation including corrosion resistant status, as well as the Design Criteria section per- taining to special design considerations.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K=5.6 gpm/psi"2 (80,6 Ipm/barl/2) K=8.0 gpm/psi112 (115,2 1pm/barll2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table E. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Button ......................Brass/Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector .........................Copper Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria TYCO Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizon- tal Sidewall Sprinklers Quick and Stan- dard Response (Light Hazard) must be installed and utilized in Light Hazard Occupancies, under smooth ceilings as outlined in the appliable installation standard recognized by the Approval Agency (e.g., UL recognizes NFPA 13, and FM recognize the FM Loss Preven- tion Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applicable, is to be used for recessed installations. TFP296 Page 3 of 8 BULB _____________________ K-FACTOR SPRINKLER TEMPERATURE LIQUID SPRINKLER FINISH(5)__ T—CHROME TYPE RATING COLOR NATURAL POLYESTERC BRASS PLATED 135°F (57°C) Orange 56 1/2 in EC HSW (TY3332) 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow NPT 135°F (57°C) Orange 5.6 1/2 in. RECESSED EC HSW 1, 2,4 155°F (68°C) Red NPT (TY3332) 175°F (79°C) Yellow 135°F (57°C) Orange 5.6 1/2 in. RECESSED EC HSWb 1,2,3,4 155°F(68°C) Red NPT (TY3332) 175°F (79°C) Yellow 135°F (57°C) Orange 8.0 3/4 in. EC HSW (TY4332) 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow NPT 135°F (57°C) Orange 8.0 3/4 in. RECESSED EC HSW8 1, 2, 4 155°F (68°C) Red NPT (TY4332) 175°F (79°C) Yellow 1, 2, 3, 4 135°F (57°C) Orange 8.0 3/4 in. RECESSED EC HSWb 1, 2, 3, 4 155°F (68°C) Red NPT (TY4332) 175°F (79°C) Yellow Notes: Listed by Underwriters Laboratories, Inc. (UL) per Table C Listed by Underwriters Laboratories, Inc. for use in Canada per Table C Approved by Factory Mutual Research Corporation (FM) per Table D Approved by the City of New York under MEA 354-01-E Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed corrosion-resistant sprinklers. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable Installed with Style 20(1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable Frame and deflector only TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) SPRINKLER FINISH K-FACTOR SPRINKLER TYPE NATURAL I CHROME POLYESTER BRASS PLATED EC HSW 5.6 (TY3332) 1/2 in. 250 PSI (17,2 BAR) NPT RECESSED EC HSW OR (TY3332) 175 PSI (12,1 BAR) EC HSW 8.0 3/4 in. (1Y4332) (SEE NOTE 1) RECESSED EC HSW NPT (TY4332) Notes: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-Ui.); and, the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE TFP296 Page 4 of 8 5.6K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER (TY3332) R Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum eRating sPonse Area(11, Flow(2), Pressure(2), Distance(3), Temperature Spacing(4), ft x ft (m x m) gpm (1pm) psi (bar) Inches (mm) °F Rating, ft (m) Quick 16 x 16(4,9 x 4,9) 26(98) 21.6(1,48) 4 to 12 (100 to 300) 135, 155, 175 10(3,1) Quick 16 x 18(4,9 x 5,5) 29 (110) 26.8(1,85) 4 to 12 (100 to 300) 135, 155, 175 10(3,1) Quick 16 x 20 (4.9 x 6,1) 32 (121) 32.7 (2,25) 4 to 6(100 to 150) 135 10(3,1) Quick 16 x 22 (4,9 x 6,7) 35 (133) 39.1 (2,70) 4 to 6(100 to 150) 135 10(3,1) Standard 16 x 20(4,9 x 6,1) 32 (121) 32.7 (2,25) 4 to 6(100 to 150) 155 10(3,1) Standard 16 x 22 (4,9 x 6,7) 35 (133) 39.1 (2,70) 4 to 6 (100 to 150) 155,175 10(3,1) 8.0K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER (TY4332) Response Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum Rating Area(1JT, Flow(2), Pressure(2), Distance(3), Temperature Spacing(4), ft x ft (m x m) gpm (1pm) psi (bar) Inches (mm) °F Rating, ft (m) Quick 16 x 16 (4,9 x 4,9) 26 (98) 10.6 (0,73) 4 to 12 (100 to 300) 135, 155, 175 10 (3,1)/13 (4,0)(5) Quick 16 x 18(4,9 x 5,5) 29(110) 13.1 (0,90) 4 to 12 (100 to 300) 135, 155, 175 10(3,1)/13 (4,0)(5) Quick 16 x 20 (4.9 x 6,1) 32 (121) 16.0(1,10) 4 to 6(100 to 150) 135 10 (3,1)/13 (4,0)(5) Quick : 16 X 20(4.9 X 6,1) 33(125) 17.0 (1,17) 4 to 12 (100 to 300) 135 10 (3,1)/13 (4,0)(5) Quick 16 x 22 (4,9 x 6,7) 35 (133) 19.1 (1,32) 4 to 6(100 to 150) 135 10 (3,1)/13 (4,0)(5) Quick 16 x 22(4,9 x 6,7) 36(136) 20.3(1,59) 4 to 12 (100 to 300) 135 10 (3,1)/13 (4,0)() Quick 16 x 24(4,9 x 7,3) 39 (148) 23.8(1,64) 4 to 6(100 to 150) 135 10 (3,1)/13 (4,0)(5) Quick 16 x 24(4,9 x 7,3) 40 (151) 25.0 (1,72) 4 to 12 (100 to 300) 135 10 (3,1)/13 (4,0)(5) Standard 16 x 20 (4.9 x 6,1) 32 (121) 16.0 (1,10) 4 to 6 (100 to 150) 155 - 10 (3,1)/13 (4,0)(5) Standard 16 x 20 (4.9 x 6,1) 33 (125) 17.0 (1,17) 4 to 12 (100 to 300) 155 10 (3,1)/13 (4,0)(5) Standard 16 x 22 (4,9 x 6,7) 35 (133) 19.1 (1,32) 4 to 6(100 to 150) 155,175 10 (3,1)/13 (4,0)(5) Standard 16 x 22 (4,9 x 6,7) 36(136) 20.3 (1,59) 4 to 12 (100 to 300) 155,175 10 (3,1)/13 (4,0)(5) Standard 16 x 24 (4,9 x 7,3) 39 (148) 23.8 (1,64) 4 to 6 (100 to 150) 155,175 10 (3,1)/13 (4,0)(5) Standard 16 x 24(4,9 x 7,3) 40(151) 25.0 (1,72) 4 to 12 (100 to 300) 155,175 10(3,1)/13 (4,0)(5) Notes: Backwall (where sprinkler is located) by sidewall (length of throw) Requirement is based on minimum flow in gpm from each sprinkler. The indicted residual pressures are based on the nominal K-factor. The centerline of the sprinkler waterway is located 7/16 in. (11,1 mm) below the deflector (Ref. Figures 1 and 2). Minimum spacing is for lateral distance between sprinklers located along a single wall, otherwise adjacent sprinklers (i.e., sidewall sprinklers on an adjacent wall, on an oppo- site wall, or pendent sprinklers) must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized. Minimum spacing is 13 ft (4,0 m) when design pressure exceeds 175 psi (12,1 bar), otherwise the minimum spacing is 10 ft (3 m). TABLE C UL AND C-UL LISTING COVERAGE AND FLOW RATE CRITERIA TFP296 Page 5 of 8 5.6K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER (1Y3332) Coverage Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum ReRs1onse ating Area('( Flow(2), Pressure(2), Distance(3), Temperature Spacing(4), fix ft (m x m) gpm (1pm) psi (bar) Inches (mm) Rating, F ft (m) Quick 16 x 16(4,9 x 4,9) 26(98) 22(1,51) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 18(4,9 x 5,5) 30(114) 29(2,00) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 20 (4.9 x 6,1) 33 (125) 35 (2,41) 4 to 12 (100 to 300) 135,155 10(3,1) Standard 16 x 16(4,9 x 4,9) 26 (98) 22 (1,51) 4 to 12 (100 to 300) 175 10(3,1) Standard 16 x 20 (4,9 x 6,1) 30 (114) 29 (2,00) 4 to 12 (100 to 300) 175 10(3,1) Standard 16 x 22 (4,9 x 6,7) 33 (125) 35 (2,41) 4 to 12 (100 to 300)) 175 10(3,1) 8.0K EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER (TY4332) Response Coveraqe Minimum Minimum Deflector-to-Ceiling Sprinkler Minimum Rating Area(11 Flow(2), Pressure(2), Distance(3), Temperature Spacing(4), fix ft (m x m) gpm (1pm) psi (bar) Inches (mm) °F Rating, ft (m) Quick 16 x 16(4,9 x 4,9) 32(121) 16(1,10) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 18(4,9 x 5,5) 36(136) 20(1,38) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 20(4.9 x 6,1) 40(151) 25 (1,72) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 22 (4,9 x 6,7) 44(167) 30 (2,06) 4 to 12 (100 to 300) 135,155 10(3,1) Quick 16 x 24(4,9 x 6,7) '48(182) 36(2,48) 4 to 12 (100 to 300) 135,155 10(3,1) Standard 16 x 16(4,9 x 4,9) 32(121) 16 (1,10) 4 to 12 (100 to 300)) 175 10(3,1) Standard " 16 x 18(4,9 x 5,5) 36(136) 20 (1,38) 4 to 12 (100 to 300) 175 10(3,1) Standard 16 x 20(4.9 x 6,1) 40(151) 25 (1,72) 4 to 12 (100 to 300)) 175 10(3,1) Standard 16 x 22 (4,9 x 6,7) 44(167) 30 (2,06) 4 to 12 (100 to 300) 175 10(3,1) Standard 16 x 24(4,9 x 6,7) 48 (182) 36 (2,48) 4 to 12 (100 to 300) 175 10(3,1) Notes: Backwall (where sprinkler is located) by sidewall (length of throw) Requirement is based on maintaining both minimum flow and minimum residual pressure. The centerline of the sprinkler waterway is located 7/16 in. (11,1 mm) below the deflector (Ref. Figures 1 and 2). Minimum spacing is for lateral distance between sprinklers located along a single wall, otherwise adjacent sprinklers (i.e., sidewall sprinklers on an adjacent wall, on an oppo- site wall, or pendent sprinklers) must be located outside of the maximum listed protection area of the extended coverage sidewall sprinkler being utilized. TABLED FM COVERAGE AND FLOW RATE CRITERIA TFP296 Page 6 of 8 WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END 'B" USED FOR 3/4" NPT MODELS) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation TYCO Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizon- tal Sidewall Sprinklers Quick and Stan- dard Response (Light Hazard) must be installed in accordance with this section. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm). A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 lb-ft (9,5 to 19,0 N.m). A leak tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 to 20 lb-ft (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-FRB EC Sidewall Sprinkler The Series TY-FRB EC Sidewall Sprin- klers must be installed in accordance with the following instructions: Step 1. Horizontal sidewall sprinklers are to be installed with their center- line perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the deflector is to face towards the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 3). With reference to Figures 1 and 2, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. Series TY-FRB Recessed EC Sidewall Sprinkler The Series TY-FRB Recessed EC Sidewall Sprinklers must be installed in accordance with the following instructions: Step 1. Horizontal sidewall sprinklers are to be installed with their center- line perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the deflector is to face towards the ceiling. Step 2. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 4). With reference to Figure 1 or 2, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step 4. After the wall has been installed or the finish coat has been applied, slide on the Style 10, 20, 30, or 40. Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the wall. Care and Maintenance TYCO Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizon- tal Sidewall Sprinklers Quick and Stan- dard Response (Light Hazard) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire pro- tection system that it controls, per- mission to shut down the affected fire protection system must be obtained from the proper authorities and all per- sonnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent oper- ation may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to Installa- tion Section.) Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP296 Page 7 of 8 5/8±1/4" (15,9±6,4 mm) MOUNTING - FACE OF SURFACE SPRINKLER FITTING CLOSURE 2-7/8" DIA. SERIES (73,0 mm) 2-1/4" DIA. TY-FRB EC MOUNTING - (57,2mm) PLATE (3,2 mm) 1-1/4" (31,8 mm) 3/4" (19,1 mm) 3/4" (19,1 mm) 1/4 (6,4 mm) FIGURE 5 SERIES TY-FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACOTR, 1/2 INCH NPT 5/8±1/4" - (15,9±6,4 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING MOUNTIN CLOSURE 1 2-7/8 DIA. SERIES (73,0 mm) TY-FRB EC 2-1/4 01k (57,2 mm) PLATE 1 4 1/8" (3,2 mm) 1-1/4" (31,8 mm) 3/4" (19,1 mm) 3/4" (19,1 mm) 1/4" (6,4 mm) FIGURE 7 SERIES TY-FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT 1/2±1/8' - (12,7±3,2 mm) MOUNTING FACE OF SURFACE . SPRINKLER FITTING CLOSURE 1 2-7/8 DIA. SERIES (73,0 mm) TY-FRB EC 2-1/4" 01k 2mm) MOUNTING PLATE (57, (3,2 mm) 1-1/4" (31,8 mm) 1/2" (12,7 mm) 1" (25,4 mm) - 1/4 (6,4 mm) FIGURE 6 SERIES TY-FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 1/2±1/8 (12,7±3,2 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING f CLOSURE 1 2-7/8 DIA. SERIES (73,0 mm) 2 1/4" DIA. TV-FRB EC 2 mm) MOUNTING PLATE 1/8 (3,2 mm) 1-1/4" (31,8 mm) 1/2" (12,7 mm) 1(25,4mm) 1/4(6,4mm) FIGURE 8 SERIES TY-FRB RECESSED EC SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT TFP296 Page 8 of 8 57-XXX-X-XXX II I SPRINKLER FINISH I 1 NATURAL BRASS I TEMPERATURE I I SIN I - 3 PURE WHITE (RAL9010) RATING I I I POLYESTER I 135 135°F (57°C) 376 I 5.6K EC HSW TY3332 - I 4 SIGNAL WHITE (RAL9003) I 155 155°F (68°C) 396 8.0K EC HSW 1Y4332 POLYESTER I - 1 175 175°F(79°C) 5 JET BLACK (RAL9005) POLYESTER 9 1 CHROME PLATED TABLE SERIES TY-FRB EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLERS PART NUMBER SELECTION Limited Warranty For warrany terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assembly with NPT Thread Connections Specify: Series TY-FRB, (specify SIN), Extended Coverage Horizontal Side- wall Sprinkler, K=(specify), (specify) temperature rating, (specify) finish, P/N (specify from Table F) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 194401 Telephone +1-215-302-0700 Alto e2olaJoft.,00n Controfo. AD ,ihto noonrood. AD specifications ond other inton,,otion ohownwn,e current no of document ronlnIo. dodo ondo,. nobjootto ohonaowlthooi notion. Johnson NATIONAL FIRE PROTECTION ASSOCIATION nod NFPA n,e ,ogIotond trodonobo Of National Fan P,Otoot,on Aa,ociotia Controls TEflON i o,00loto,nd nodoandt of EnRoot