Loading...
HomeMy WebLinkAbout1905 CALLE BARCELONA; 211; AS110127; PermitCity of Carlsbad Sprinkler Permit Permit No: AS110127 1905 CALLE Job Address: BARCELONA Permit Type: SPRINK Parcel No: 2550120400 Lot #: 0 Reference No.: PC #: Status: PENDING Applied 8/25/2011 Approved: Issued: Inspector: Project Title: BODYROK-SUITE 211 T.I.-SPRINKLER Applicant: Owner: Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 AS i ~o ~ ~-+ FIR E :3fl INKLER'S. INC. BODYROK THE FORUM AT CARLSBAD 1905 CALLE BARCELONA, BLDG 1, SUITE #211 CARLSBAD, CA 92009 FIRE SPRINKLER SUBMITTALS MANUFACTURER DATA SHEETS ** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/SIN. V2704 AND V2708 QUICK RESPONSE These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. The design incorporates state-of-the-art, heat responsive, frangible glass bulb design (standard or quick response) for prompt, precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 2) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up to 3/4719 mm of adjustments. UPRIGHT PENDENT RECESSED (V2703 AND (V2707 AND PENDENT V2704) V2708) (V2707 AND V2708) SPRINKLER OPERATION The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient temperature rises causing the liquid in the bulb to expand. When the ambient tem- perature reaches the rated temperature of the sprinkler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE For coverage area and sprinkler placement, refer to NFPA 13 standards. TECHNICAL SPECIFICATIONS Models/SIN.: V2703, V2704, V2707, V2708 9 Style: Pendent, Upright or Recessed Pendent ACCESSORIES Nominal Orifice Size: ½'/13mm K-Factor: 561mp /8.1 SI!' Installation Wrench: Nominal Thread Size: ½ NPT/15mm • Open End: V27 Max. Working Pressure: • Recessed: V27-2 175 psi/1200 kPa FM Global Finishes: 250p5i/1725kPa UL • Plain brass Factory Hydrostatic Test: • Chrome plated 100% © 500p5i/3450kPa • White painted** Ih Mm. Operating Pressure: 7psi/48kPa • Black painted** Temperature Rating: See charts on page 2 & 3 • Custom painted** Proprietary nickel Teflon* coating** MATERIAL SPECIFICATIONS For cabinets and other accessories refer to Upright Deflector: Bronze per UNS C22000 separate sheet. Pendent Deflector: Bronze per UNS C51000 NOTE: Weather resistant recessed escutcheons Bulb: Glass with glycerin solution. available upon request. Bulb Nominal Diameter: Standard: 5.0 mm A For K-Factor when pressure is measured in Quick Response: 3.0mm Bar, multiply S.I. units by 10.0. Load Screw: Bronze per UNS C65100 * Teflon is a registered trademark of Dupont Co. Pip Cap: Bronze per UNS C65100 **UL Listed for corrosion resistance in all Spring: Beryllium nickel configurations. Exaggerated for clarity Seal: Teflon tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com vicrAuLic IS A REGISTERED TRADEMARK OF VICTAUUC COMPANY. C 2010 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV H bj6taulicr 40.10 1 11 FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE Orifice Size (inches) Orifice Size (mm)4. Nominal K Factor Imperial Nominal K Factor S.I. Response Deflector Type Adjustment ½' 5.6 8.1 Standard Upright ½' 5.6 8.1 Standard Pendent ½' 13 5.6 8.1 Standard Recessed Pendent uptoN'- ½' 13 5.6 8.1 Quick Upright ½' 13 5.6 8.1 Quick Pendent ½' 13 5.6 8.1 Quick Recessed Pendent Up to Y4 Approved Temperature Ratings F~/U Agency by 135'F/57'C 135'F/57'C 155'F/681C 155'F/68'C 135'F/57'C 135'F/57°C 135'F/57'C 135'F/57'C 175'F/79'C 175'F/79'C 155'F/68'C lSS°F/68'C 155'F/68'C 1SS'F/68'C UL 200'F/93'C 200'F/93'C 175'F/79'C 175'F/79'C 175'F/79'C 175'F/79'C 286'F/141'C 286'F1141'C 200'F/93'C 200'F/93'C 200'F/93'C 200'F/93'C 360'F/182'C 360'F/182°C 286'F/141'C 286'F/141'C 286'F/141'C 135'F/57'C 135'F/57'C 135'F/57'C 135'F/57'C 135'F/57'C I55'F/68'C 155'F/68'C 155'F/68'C 155'F/68'C 155'F/68'C 135'F/57'C ULC 175'F/79'C 175'F/79'C 175'F/79'C 175'F/79'C 175'F/79'C I55'F/68'C 200'F/93'C 200'F/93'C 200 'F/93'C 200'F/93'C 200'F/93'C 175°F/79'C 286'F/141'C 286'F/141'C 286'F/141'C 285'F/141'C 286'F/141 'C 200'F/93'C 360'F/182'C 360°F/182'C 135'F/57'C 135'F/57'C t3S'F/57'C 135'F/57'C 155'F/68'C 155'F/68'C 135'F/57'C I55'F/68'C 155'F/68'C I3S'F/57'C FM U 175'F/79'C 175'F/79'C 155'F168C 175'F/79'C 175'F/79°C lSS'F/68'C 200'F/93'C 200'F/93'C 175'F/79'C 200'F/93'C 200'F/93'C 175'F/79'C 286'F/141'C 286'F/141'C 200°F/93'C 286'F/141'C 286'F/141'C 200'F/93'C 360'F/182'C 360'F/182'C 135'F/57'C 135°F/57'C I35'F/57'C 135'F/57'C 135'F157'C 155' 1 75'F/68 'C F/79'C 155'F/68'C t5S'F/68'C 155'F/68'C 155'F/68'C 135'F/57'C NYC/MEA U 62-99-E S 175'F/79'C I75'F/79'C I75'F/79'C 175'F/79'C 1SS'F/68'C 200'F193'C 200'F/93'C 200'F/93'C 200'F/93'C 200'F/93'C 175'F/79'C 286'F/141'C 286'F/141'C 286'F/141'C 286'F/141'C 286'F/141'C 200'F/93'C 360'F/182°C 360'F1182'C 135'F/57'C I35'F/57'C 135'F/57'C 135'F/57'C - 135'F/57'C I55'F/68'C 155'F/68'C ISS'F/68'C 155'F/68'C 155'F/68'C 135'F/57°C CSFM U 7690-0531r112 175'F/79'C 175'F/79'C 175'F/79'C 175'F/79'C 175'F/79'C 155'F/68'C 200'F/93'C 200'F/93'C 200'F/93'C 200'F/93'C 200'F/93'C t7S'F/79'C 286'F/141'C 286'F/141'C 286'F/141'C 286'F,'141'C 286'F/141'C 200'F/93'C 360'F/182'C 360'F/1 82'C t35'F/57'C 135'F/57'C 155'F/68'C 135'F/57'C 155'F/68'C I35'F/57'C LPCB 175'F/79'C 175 Ff79 C 175'F/79'C 175'F/79'C None None 200'F/93'C 200'F/93'C 200'F/93'C 200'F/93'C 286'F/141'C 286'F/141'C 360'F/182'C 135'Ff57'C 135'F/57'C 135'Ff57'C 135'F/57'C 155'F/68'C 155'F/68'C 135'F/57'C 155'F/68'C 1SS'F/68'C 135 Ff57 C VNIIPO 175'F/79'C 1 75'F/79'C I55'F/68'C 175'F/79'C 175'F/79'C 155'F/68'C 200'F/93'C 200'F/93'C 175'F/79'C 200'F193'C 200'F/93'C 75 F/79 C 286'F/141'C 286F/141'C 200'F/93'C 286'F/141'C 286'F/141'C 200'F/93'C 360'F/182'C 360'F/182'C ZSTZ ZSTX K-ZSTZ K-ZSTX ccc I55'F/68 ' C 1SS'F/68'C None 155'F/68'C 155'F/68'C None 200'F193'C 200'F/93'C 200'Ff93'C 200'F/93'C F Listings and Approvals as of printing. All are approved open, except for areas designated 'No'. For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with /2' adjustment escutcheon only - quick response .- www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. -U1 iiie 40.102 REV H FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE 40.10 RATINGS All glass bulbs are rated for temperatures from -67°F/-55°C to those shown in table below. raiThTTT1M Cla ifica ji on ldenlificafion-~~~ Ordinary A 35 57 100 38 M11 Orange Ordinary C 155 68 100 38 Red Intermediate E 175 79 150 65 Yellow Intermediate F 200 93 150 65 Green High 286 225 Blue 141 107 Extra High K 4 360 182 300 149 Purple -* M Open — No Bulb * Standard response only. All are approved openexcept for areas designated 'No'. 150/65 if wax coated. ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number S Style Temperature Rating K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number www.victaulic.com vICTAuLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. RE V jA _r_ ta uI i C 40.103 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40.10 C V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE WARNING A WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. O s Painting, plating, or any re-coating of sprinklers (other than that sup- plied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association document NFPA 25 that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may ________ have additional maintenance, testing, and inspection requirements that must be followed. IN If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044.0031 USA, Telephone: 001-610-559-3300. DIMENSIONS Standard Pendent - V2707, V2708 Standard Upright - V2703, V2704 I 33RWW I 4 fl RiVal Valin 41 2Wl mm r33 60 mm HOWVX/ TL l%l 25 mm ½" Adjustment Recessed - V2707, V2708 (drawing not to scale) 2W/HO mm MaxHole 275 1 mm Mm Hole Typical Ceiling ri 1 T- f ,304 7mm m 131.7 I'll,., Finished Surface 30 nm 43 mm MAXIMUM RECESS 75 min MAXIMUM EXTENSION www.victaulic.com An—telul—af VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 4010 4 REV H 24 mm FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE 40.10 DIMENSIONS 3/4" Adjustment Recessed - V2707, V2708 (drawing not to scale) 75 mm MAXIMUM EXTENSION AVAILABLE WRENCHES Sp,inke, Type V27-2 Recessed V27 Open V2707,V27O8Pendent yes yes V2707, V2708 Recessed Pendent yes - V2703, V2704 Upright yes yes Models/S.I.N. V2707, V2708 K5.6 standard pendent and recessed pendent distribution patterns - trajectory 10' 3.0m 1. 2.4m 1.8m 4, 1.2m 2' 0.6m 2' 4' 0.6m 1.2m 7ps1 48 kPa See notes on next page. El DISTRIBUTION PATTERNS 4 4 S 4 4 4 4 4 4 4 4 4 4 6' 8' 10' 12' 14' 1.8m 2.4m 3.0m 3.7m 4.3m 15 psi 30p11 103kPa 207kPa S www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2010 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV Ant-s -U1 i a 4010.5 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE DISTRIBUTION PATTERNS Models/S.I.N. V2703, V2704 K5.6 standard upright distribution patterns - trajectory 0. 3.Om! 2.4m 6 1.8m 4, 1.2m 0.6m 444 4444,, S 2 4 6 8. 10' 12 0.6,,, 1.2,,, 1.8m 2.4m 3Cm 3.7m 7ps1 15 psi 30 psi 48 W 103kPa 207kPa 14 16 4.3m 4.9,,, NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NIPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 40.10 2544 REV H UPDATED 07/2010 iCtQUII VICTAULIC IS A REGISTERED TRADEMARK OF ITAULI COMPANY. 02010 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. Cr