Loading...
HomeMy WebLinkAbout2668 GATEWAY RD; 170; FPC2019-0166; Permitcity of PERMIT REPORT Carlsbad Fire Permi t Print Date: 10/18/2021 Permit No: FPC2019-0166 Job Address: 2668 GATEWAY RD, # 170, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132622100 Track #: Applied: 07/23/2019 Valuation: $233,097.29 Lot #: Issued: 07/29/2019 Occupancy Group: Project #: DEV12023 Finaled Close Out: 05/26/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: UPTOWN BRESSI RANCH Description: WOOD RANCH BBQ- SPRINKLER TI (48 HEADS) Applicant: FPContractor: PARAMOUNT FIRE SYSTEMS INC PARAMOUNT FIRE SYSTEMS INC JAMES CHENEY P0 BOX 713194 8069 WING AVE SANTEE, CA 92072-3194 EL CAJON, CA 92020-1245 (619) 562-6247 (619) 562-6247 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 760-602-8561 f I www.carlsbadca.gov HYDRAULIC SYSTEM This Building Is Protected By A Hydraulically Designed Automatic Sprinkler System PROJECT: WOOD RANCH GRILL TENANT IMPROVEMENT CONTRACTOR: DESIGNED BY PARAMOUNT FIRE SYSTEMS, INC. REMOTE AREA: AREA 1; EXTERIOR DINING AREA REMOTE AREA: HAZARD: LH _X_ OH-1 OH-11 - EH-1 EH-11 RES - NFPA STANDARD: NFPA13 EDITION: 2013 SYSTEM TYPE: WET AREA/SPRINKLER: 225 SQ. FT. USED; 225 SQ. FT. ALLOWED MANUFACTURER: TYCO MODEL TYPE K-FACTOR SIZE DEGREE QTY SEE FIRE SPRINKLER LEGEND ON FP1 CALCULATION DATA: DENSITY/AREA: .10 GPM/SF OVER Entire Area (Dining Patio) END SPRINKLER: 22.5 GPM @ 16.1 PSI. NO. OF SPRINKLERS FLOWING: 10 HOSE STREAM ALLOWANCE: 100 GPM. RACK DEMAND: NA DEMAND: AT BASE OF RISER 242.1 GPM @ 49.1 PSI AT PUMP DISCHARGE NA GPM @ NA PSI AT SOURCE 342.1 GPM @ 49.1 PSI FPC20I9-0166 2668 GATEWAY RD #170 WOOD RANCH BBQ - SPRINKLER TI (48 HEADS) DEV12023 2132622100 7123/2019 FPC20I9-0166 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 7/22/2019 C:\CALC FILES\PARAMOUNT\WOOD RANCH.SDF JOB TITLE: WOOD RANCH GRILL AREA 1 WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) BR 108.0 89.2 502.0 98.8 342.1 49.1 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 342.1 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 242.1 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) BR 1.0 SOURCE 49.1 242.1 TR 14.8 - - - - 42.9 - - - 1 14.8 - - - - 40.6 - - - 2 14.8 - - - - 39.0 - - - 3 14.8 - - - - 38.7 - - - 4 14.8 - - - - 28.4 - - - 5 12.0 - - - - 25.2 - - - 6 12.0 - - - - 24.8 - - - 7 12.0 - - - - 22.6 - - - 8 12.0 - - - - 21.8 - - - 9 12.0 - - - - 21.8 - - - 10 12.0 - - - - 22.5 - - - 11 12.0 - - - - 23.9 - - - 12 12.0 - - - - 23.9 - - - 13 14.8 - - - - 33.4 - - - 101 12.0 K= 5.60 23.4 27.1 102 12.0 K= 5.60 18.7 24.2 103 12.0 K= 5.60 17.2 23.2 104 12.0 K= 5.60 18.1 23.8 105 12.0 K= 5.60 16.1 22.5 106 12.0 K= 5.60 18.0 23.8 107 12.0 K= 5.60 16.7 22.9 108 12.0 K= 5.60 19.0 24.4 109 12.0 K= 5.60 17.8 23.6 110 12.0 K= 5.60 22.5 26.6 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 7/22/2019 C:\CALC FILES\PARAMOUNT\WOOD RANCH.SDF JOB TITLE: WOOD RANCH GRILL AREA 1 PIPE DATA S S S PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1. 242.1 4.310 PL 13.75 PF 0.2 BR 1.0 SRCE 49.1 (N/A) 5.3 120 FTG ---- PE -6.0 TR 14.8 0.0 42.9 0.0 0.013 TL 13.75 PV Pipe: 2 242.1 3.334 PL 26.67 PF 2.3 TR 14.8 0.0 42.9 0.0 8.9 120 FTG 3L PE 0.0 1 14.8 0.0 40.6 0.0 0.047 TL 49.17 PV Pipe: 3 242.1 3.334 PL 12.00 PF 1.6 1 14.8 0.0 40.6 0.0 8.9 120 FTG T PE 0.0 2 14.8 0.0 39.0 0.0 0.047 TL 34.49 PV Pipe: 4 117.8 3.334 PL 29.00 PF 0.4 2 14.8 0.0 39.0 0.0 4.3 120 FTG ---- PE 0.0 3 14.8 0.0 38.7 0.0 0.012 TL 29.00 PV Pipe: 5 124.3 1.728 PL 20.33 PF 10.6 2 14.8 0.0 39.0 0.0 17.0 120 FTG T PE 0.0 4 14.8 0.0 28.4 0.0 0.336 TL 31.62 PV Pipe: 6 124.3 1.728 PL 7.50 PF 4.4 4 14.8 0.0 28.4 0.0 17.0 120 FTG 2L PE 1.2 5 12.0 0.0 25.2 0.0 0.336 TL 13.14 PV Pipe: 7 27.1 1.728 PL 7.50 PF 0.4 5 12.0 0.0 25.2 0.0 3.7 120 FTG T PE 0.0 6 12.0 0.0 24.8 0.0 0.020 TL 18.79 PV Pipe: 8 97.2 1.728 PL 0.75 PF 2.6 5 12.0 0.0 25.2 0.0 13.3 120 FTG T PE 0.0 7 12.0 0.0 22.6 0.0 0.213 TL 12.04 PV Pipe: 9 49.8 1.728 PL 12.00 PF 0.7 7 12.0 0.0 22.6 0.0 6.8 120 FTG ---- PE 0.0 8 12.0 0.0 21.8 0.0 0.062 TL 12.00 PV Pipe: 10 3.5 1.728 PL 8.25 PF 0.0 8 12.0 0.0 21.8 0.0 0.5 120 FTG L PE 0.0 9 12.0 0.0 21.8 0.0 0.000 TL 11.07 PV Pipe: 11 -43.2 1.728 PL 13.00 PF 0.6 9 12.0 0.0 21.8 0.0 5.9 120 FTG ---- PE 0.0 10 12.0 0.0 22.5 0.0 0.048 TL 13.00 PV Pipe: 12 -91.2 1.728 PL 7.67 PF 1.5 10 12.0 0.0 22.5 0.0 12.5 120 FTG ---- PE 0.0 11 12.0 0.0 23.9 0.0 0.190 TL 7.67 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 7/22/2019 C:\CALC FILES\PARANOUNT\WOOD RANCH.SDF JOB TITLE: WOOD RANCH GRILL AREA 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 26.6 1.728 PL 2.17 PF 0.0 11 12.0 0.0 23.9 0.0 3.6 120 FTC ---- PE 0.0 12 12.0 0.0 23.9 0.0 0.019 TL 2.17 PV Pipe: 14 -117.8 1.728 PL 9.83 PF 10.7 11 12.0 0.0 23.9 0.0 16.1 120 FTG 2TL PE -1.2 13 14.8 0.0 33.4 0.0 0.304 TL 35.23 PV Pipe: 15 -117.8 1.728 PL 3.00 PF 5.2 13 14.8 0.0 33.4 0.0 16.1 120 FTG TL PE 0.0 3 14.8 0.0 38.7 0.0 0.304 TL 17.11 PV Pipe: 16 27.1 1.080 PL 2.00 PF 1.4 6 12.0 0.0 24.8 0.0 9.5 120 FTG T PE 0.0 101 12.0 5.6 23.4 27.1 0.198 TL 7.00 PV Pipe: 17 47.4 1.080 PL 2.00 PF 3.9 7 12.0 0.0 22.6 0.0 16.6 120 FTC T PE 0.0 102 12.0 5.6 18.7 24.2 0.558 TL 7.00 PV Pipe: 18 23.2 1.080 PL 10.00 PF 1.5 102 12.0 5.6 18.7 24.2 8.1 120 FTC ---- PE 0.0 103 12.0 5.6 17.2 23.2 0.149 TL 10.00 PV Pipe: 19 46.3 1.080 PL 2.00 PF 3.7 8 12.0 0.0 21.8 0.0 16.2 120 FTG T PE 0.0 104 12.0 5.6 18.1 23.8 0.534 TL 7.00 PV Pipe: 20 22.5 1.080 PL 12.00 PF 2.0 104 12.0 5.6 18.1 23.8 7.9 120 FTC E PE 0.0 105 12.0 5.6 16.1 22.5 0.140 TL 14.00 PV Pipe: 21 46.7 1.080 PL 2.00 PF 3.8 9 12.0 0.0 21.8 0.0 16.4 120 FTG T PE 0.0 106 12.0 5.6 18.0 23.8 0.542 TL 7.00 PV Pipe: 22 22.9 1.080 PL 9.00 PF 1.3 106 12.0 5.6 18.0 23.8 8.0 120 FTC ---- PE 0.0 107 12.0 5.6 16.7 22.9 0.145 TL 9.00 PV Pipe: 23 48.0 1.080 PL 1.08 PF 3.5 1.0 12.0 0.0 22.5 0.0 16.8 120 FTC T PE 0.0 108 12.0 5.6 19.0 24.4 0.571 TL 6.08 PV Pipe: 24 23.6 1.080 PL 8.00 PF 1.2 108 12.0 5.6 19.0 24.4 8.3 120 FTC ---- PE 0.0 109 12.0 5.6 17.8 23.6 0.153 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 7/22/2019 C:\CALC FILES\PARAMOUNT\WOOD RANCH.SDF JOB TITLE: WOOD RANCH GRILL AREA 1 PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 26.6 1.080 PL 2.25 PF 1.4 12 12.0 0.0 23.9 0.0 9.3 120 FTG T PE 0.0 110 12.0 5.6 22.5 26.6 0.191 TL 7.25 PV NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 16071188 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.061 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 17.0 ft/sec at pipe 6. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. -Available pressure at source node BR under full flow conditions is 92.86 psi with a flow of 446.60 gpm. PIPE FITTINGS TABLE User Pipe Table Name: STANDARD1.PIP PAGE: G MATERIAL: Eddyf low HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.728 5.64 11.29 2.82 12.70 8.47 1.41 14.11 14.11 11.29 3.334 10.49 22.49 7.50 23.99 14.99 1.50 19.49 19.49 22.49 4.310 13.94 27.87 8.36 30.66 16.72 2.79 27.87 27.87 27.87 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page, 5 DATE: 7/22/2019 C:\CALC FILES\PARANOUNT\WOOD RANCH.SDF JOB TITLE: WOOD RANCH GRILL AREA 1 PAGE: H MATERIAL: Eddythread HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngE11 ChkVlv Hf yVlv GatVlv AlmChk DPV1v NPTee 1.080 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 LEGEND Available pressure 98.75 psi @ 342.1 .gpm Required pressure 49.09 psi @ 342.1 gpm Avail. OnSite Demand PresE 98.75 psi @ 242.1 gpm Req. OnSite Demand Press. 49.09 psi @ 242.1 gpm Source Supply Curve System Demand Curve Available at Source 121). 100. G A U 80. G E P R 60. E S S U R 40.' E p 20. S 1 [oP -14. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 7/22/2019 C:\CALC FILES\PARAMOUNT\WOOD RANCH.SDF JOB TITLE: WOOD RANCH GRILL AREA 1 WATER SUPPLY ANALYSIS Static: 108.00 psi Resid: 89.20 psi Flow: 502.0 gpm 12(180240 300 360 420 480 540 600 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 7/22/2019 C:\CALC FILES\PARAMOUNT\WOOD RP.NCH.SDF JOB TITLE: WOOD RANCH GRILL AREA 1 WATER SUPPLY CURVE 108*\\ I \\ \\ \\ 99+ \\ I \\ I \\ 90+ * <-89.2 psi @ 502 gpm Flow Test Point 81+ P 72+ RI El SI S 63+ UI RI El 54+ x SI I 45+ ) I 36+ 27+ 18+ LEGEND 'I I, I X = Required Water Supply 49.09 psi @ 342.1 gpm 9+ I 0 = Available Water Supply I 98.75 psi ® 342.1 gpm I it 0++_+_ - -+- - - -+ -----+ ------+ --------+ --------+ ---------+ -----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) tqca Worldwide www.tyco-fire.com Contacts Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TV- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE I The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) 1Y313 .......Upright 5.6K, 1/2 NPT 1Y323 ......Pendent 5.6K, 1/2 NPT Technical Data Approvals UL and C-UL Listed FM and VdS Approved CE Certified Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar) *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/ps1112 (80,6 LPM/bar1/2) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) JANUARY 2013 ,•- ----. T1I Finishes Sprinkler: Natural Brass, Chrome Plated, Pure White (RAL 9010) and Signal White (RAL 9003). Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 2" (50,8 (50,8 mm) I 1-3/8" (34,9 mm) DEFLECTOR * PENDENT WF Fl 2-7/8" 3,0 mm) DIA. RECESSED PENDENT TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression 3 - Sealing Screw ESCUTCHEON PLATE 1/2' 7/16' (11,1 mm) Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN CROSS SECTION UPRIGHT FIGURE 1 SERIES TV-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE MA I 7/16 I (11,1 mm) I NOMINAL MAKE-IN 2" (50,8 mm) 1/2" NPT** STYLE 15 or 20 RECESSED ESCUTCHEON Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. - 2-7/8 DIA. (73,0 mm) 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER FITTING - 5/8 (15,9 mm) FLUSH 3/8±5/16 (9,5±7,9 mm) ) \ I MOUNTING / SURFACE/ • L (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON - 2-7/8 DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4° DIA. FITTING - (57,2 mm) 5/16±1/4' 1/2° (12,7 mm) (7,9±6,4 mm) FLUSH / MOUNTING . J SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8"(34,9mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N* 77 - XXX - X - XXX I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2NPT) TY313 4 SIGNAL WHITE (RAL 9003) 371 5.6K PENDENT (1/2 NPT) 1Y323 3 PURE WHITE (RAL 9010)" Use suffix °I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS - PART NUMBER SELECTION - Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (SIN), K=5.6, (Upright or Pendent) Sprinkler Quick Response, (specify) temperature rat- ing, (specify) finish, P/N (Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TF13770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 135 135°F(57°C) 155 155°F (68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. t TEFLON is trademark of The DuPont Corporation. Mechanical-I® STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic Mechanical_i® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HOPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 110 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T' nitrite Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved Date JOB/OWNER System No. Location Para www.victaulic.com vIcTAULIC IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. © 2012 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV..M JtaUIic' 11.02._i DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N Size ax. Work e,,ur,C Dimensions Approx. Weight Each 920N 500 1.50 2.00 2.53 1.61 : 2.75 3.1 50 . 1S' 3450 38.1 51 64 - 41 136 70 1.5 - ~(a)a 920N 500 3450 1.50 38.1 1.97 2.53 50 64 - 1.61 41 5.35 136 2.75 70 1 3.1 - 13 J'L1 a1 920N 500 3450 i 130 38.1 1.85 2.53 64 1.61 ±U 5.35 136.20 2.75 3.0 J _1 V. (a) fai 920N r'32j 500 3450 1.75 44.5 2.05 2.75 52 .q 3.00 .61 L. 5.35 136 3.00 7...1.7 3.5 3.2 1.5 f.(1½(a)fa( Wta_920N 500 3450 1.75 44.5 2.03 2.75 52 I 70 3.12 79 1.61 41 5.35 136 3.25 83 3.6 1.7 3.2 1.5 21/2 ½ (a) 920N 65,.a15ritl 500 3450 1.50 38.1 2.21 2.74 70 56 - 1.82 46 5.64 143 2.75 70 3.0 1.4 - -- 920N , 20 1(o)a 500 3450 500 150 38.1 1.50 218 274 55 70 2.06 2.74 - 182 46 1.82 564 143 5.64 275 70 2.75 30 1.4 2.9 - . 920N 3450 38.1 52 70 - 46 143 1 70 1.4 - V. t (a) a' 920N 500 1 75 2.30 3.00 3.25 1.82 629 3.0.0 3.5 3.2 32 .. 3450 44.5 58 76 83 46 160 76 .....1.5 .11/2 6(a) a' 920N 500 200 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 ½ Ia) 920N 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 .15 . 2065 38.1 56 70 - 57 164 81 1.8 - j34 (a) .., 920N 2 300 150 2.19 275 - 2.25 6.46 3.18 3.9 1.8 : ,!"51(a) 920N 2065 300 38.1 1.50 56 70 2.07 2.75 57 225 164 6.46 81 3.18 3.8 .. 25 2065 38.1 53 70 - 57 164 81 1.7 - 11/4 (al 500 1.75 2.30 3.00 3.31 1.92 6.29 i 3.00 3.5 3.2 920N 32 i 3450 44.5 58 76 84 1 49 160 76 1.6 13 " ' V. (a) a 1 920N - A401...1! 500 200 2.28 3.00 3.31 1.92 6.29 3.25 3.5 3.3 3450 50.8 58 76 84 49 160 83 1.6 1.5 3 ' . .Y. (a) a I 920N 500 1.50 2.52 3.05 2.28 6.15 2.75 3.4 80 i,r 15.l 3450 38.1 64 78 - 58 156 70 1.6 - V. (a) a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 4 . -20&-1i 3450 38.1 63 78 - 58 156 70 1 1.6 - 1(a) ft N * •25fi 920 500 3450 150 38.1 1 2.38 3.06 61 78 - 2 .28 58 1 6.15 156 2.75 70 3.3 1.6 - aJ _ .1 ¼ (a) fa1 920N 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 a 132 (b)'j 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 ½ (a) fat N 40 (b) 920 ,........................ .............. 500 3450 2.00 50.8 2.78 3.50 71 89 3.56 90 2.28 58 6.15 156 3.25 83 4.1 1.9 3.8 1.8 -.47' 2(a) a' 920N 500 2.50 2.75 350 .............................................................. 3.56 2.28 6.75 3.88 4.9 4.6 3450 63.5 70 89 90 58 172 99 2.3 2.1 3½-a'.2, " 920N 500 2.50 3.00 3.75 2.44 6.72 3.88 3.8 190 50P'( 3450 63.5 75 - 95 62 171 1 99 - 1.8 ..Fa,TA6LE CONTINUED L.IPG.'3 t4a AaAff Pbt Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 2W BSPT clearly on order. § Vds approved for fire protection services ci LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com j'tauIic VICTAULIC IS A REGISTERED TRADEMARK OF vIcTAuLIC COMPANY. 02012 vlcTAuuC COMPANY. ALL RIGHTS RESERVED. 11.02..2 REVM A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: Has a Corrosion Resistance Ratio of 1.0 Has a Pressure Rating of 300 psi Is Lighter Weight Than Schedule 40 Is Approved by Factory Mutual and Listed by Underwriters Laboratories Is Produced in Accordance to ASTM A-135 and A-795 Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves Is Produced From Steel With Excellent Properties of Strength and Threadability . Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 9iT 1 1 461 1.083 70 11/4 2,070 1.418 51 r 1 1/2 2,547 1,654 44 V 2 4 3,308 2123 30 CORROSION RESISTANCE RATIOS 11/4 100 100 11/2 100 100 2 100 100 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems V TV V s V 1819 Clarkson Road For additional information, C US - Chesterfield, MO 63017 contact your salesperson today at V •.V V flLA MOflE TUBE (800) 325-4467 FAX: (636)537-2645 (800) 325-4467 o636) 537-2600 in the USA, or from Canada U V www.bullmoosetube.com CH (800) 882-4666 FM V A (CREV4 company e-mail:sa1es(bullmoosetube.com APPMVED All Information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the light to change product specifications without notice and without incurring obligation. 8/08 UM AP1WflO Oa Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 STRAIGHT TEE Noi*a1 Size Dimension A Appiox. WI. Each Lbs.(k) 54 0.69 0.09 0.04 54 0.81 014 8. 251 •. law 34 095 0.21 .10 24t3 0.10 54 1.17 0.31 15 2845 0.14 1.31 0.50 20 J21 23 1 1.50 0.79 25 3810 0.36 1% 135 1.19 32 44.45 054 1½ 1.94 157 On 021 2 2.25 2,43 50 57.Lc 1)0 254 210 4.33 65 6836 1.96 3 3.08 6.37 80 1823 4 339 11.03 9621 50 6 5.13 25.98 150 :30.30 11.78 MATERIAL SPECIFICATIONS Dimensional: Fittings: ASME B 16.3 Unions: ASME 816.39 Bushirs/Plugs; ASME 816.14 Material: ASTM A-l?7 Galvanizing:: ASTM A-i 53 Hot Dip Galvanizing) Threoding*: ASME 8L'20.1 Pressure Rating: Fflings: ASME 816.3 Unions: ASME 816.39 bushings/Plugs: ASME 816.14 Pressure Testn:: All malleable iron fittings are tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions are UL listed and FM Approved. British Standard threading per BS 21 available upon request. http://www.anvilintl.comlProductSearchlPrintProduct.aspx?lid=43 81 1/8/2014 Print Page 2 of 5 . 49E?~~~ Malleable Iron Screwed Fittings - Class 150 I Ad?tbUWAWCV.d ** Snfl REDUCING TEE Nominal Size _____ Dimensions Approx. W1. A . 4 0.97 0.97 0.98 0.24 43 24.64 2484 2439 0.11 14 1.04 IN 1.03 0.27 * ½ 10 2&.2 242 22.16 0.17 15 is 3 20 122 30.99 1.22 20. 1.20 30.4$ 0.37 Oil 1.36 1.36 1.26 0.49 _.1L_ 2454 165& 32.00. ~ i.O - a 1.12 1.22 08 t a, - 3121 -- A. -- 33.27 0.45 010 20 14 20 8 1.05W 32.61 1.OS 2647 1.08 21.43 0.36 016 _jj_ 1.12 23.45..45 1.12 . 1.13 23.10 0.39 0.18 ½ V lit) 30.0. 1.20 JMO 1.22 ..JPZ2L 0.43 .01Q_ 1.45 1.45 1.37 0.62 25 35.83 33.83 1 23.4' 0.28 -% ._J_ T 25 i 33J0 1.18 29.91 3810 1.500,63 0.29 m L26 th 1,36 0.48 1 32.00 734S 3454 0.22 17 ifl 1T43 036 15 20 3420 20.45 34.54 (125 T 1.50 1.36 1.50 0.67 25 13610 1 3424 3610 1 0.30 - W 1 1.26 0.53 IS 32.00 T 304814 1.37 1.31 0.61 20 1.2041~36 a al _5lO 0.71 25 gig _ 10 79.91 1 7991 32.23 0.23 ½ 15 1.26 3220 1 1.26 32.410 1.36 34.54 0.62 1 0.28 Il .20 131 28.45 1.37' 73.45 U5 3633 'TW 0.31 1¼ 32 1.67 42-42 1.67 410 138 441.13 T94 0.43 25 1½ 1.80 1.80 1.65 1.07 447 1 4112 45.12 1 41.11 0.49 2 7.02 2.02 1.73 1.45 5(1. 5L31.. Sill .4794.0.445 Dimensional: Fittings: ASME B16.3 Unions: ASME 816.39 Bushings/Plugs: ASME B 1614 Material: ASIM A.197 Galvanizing: ASTM A.153 (Hot Dip Galvanizing) Threading*: ASME B1.20.) Pressure Rating: Fittings: ASME 816.3 Unions: ASME 816.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron fittings ore tested For through wall porosity using on air under water process. Agency Approvals: All malleable iron Fittings and unions are UL listed and FM Approved. * British Standard threading per BS 21 ovaitabte upon request. REDUCI NG TE Nominal She Dimensions Appiex. Vh. Each B ½ "T 25 1.58 40.93 IN 34.54 16U 42.47 0.82 0.31 s 17, 32 'J.75 4445 133 03.36 -or 44.45 095 0A3 T 1.45 1.31 1.62 0.75 14 _.ZL. 3683 .33.21..41.15..0 1 158 1.45 1.61 0.8 1 1.75 14,4~__ IS -i*111- 34.04 - . 3ZO LS3 3684 014 (Lid ir- 20 1.45 36. 1.31 7843 1.62 1 41.15 0.82 Q.7 1½ 37 1 25 T 25 441.93 167 47.42 0.94 0.43 1W 32 1.7 13UNU 4445 U 4t4 f08 0.49 ir 116 1.44 0.78 10 32.041 33,50 0. 5 134 1.53 0. 43404 3684 0.38 14 1.45 1.45 1.62 0,92 9.83 136A3 25 4013 40.1 i 4242 1.04 0.41 _ W 41? 1.88 4715 1.8g 47.15 i.á 4623 1.34 021 T 50 iiO. 1 53.34 2]6 1 5234 1,90 48.26 1.65 0.15 http://www.anvilintl .com/ProductSearch/PrintProduct.aspx?lid=43 80 1/8/2014 Print Page 4 of 5 Malleable Iron Screwed Fittings - Class 150 REDUCING l Nomiral Size Dimensions ____ ApproL Wilach A -B C ir Wi 1.9 1.66 1.94 1.2i-- 1.5 ~ 6 918 ass _2L 8.U1 6 32.00 42J3 1W 40 1.94 49.28 1.75 4435 1.94 4928 .29 0.59 20 T -1T 130 1.80 [Of 25 4.91 3210 4572 0.49 1 TW 1.82 1.6? 1.88 1.23 75 3? 46.23 41.62 4115 0.56 1% 1.94 I.80 1.94 -ITS- 40 9.2 4512 49.28 0,0 11 132 1.45 L1 1.04 0 19.6? ?L$ 44.45 0.41 114 40 1½ 32 1 .25 1.65 4 15 1.58 40.13 1.80 J5.12 .. 1.17 0.53 1! 32 44.23 '1 82 L7F 44.45 L8U 41.75 = 0.40 1W 04 188 1.94 1.45 ..JL.. 48.22 41.15 49.28 0.L16 2 2.10 2.10 1.90 1.82 .50J4 J&3L. 48.24 0 - ½ 1.41 1.41 1.66 ---T-UF 15 3W 1$.&1 42.16 0.47 20 132 38.61 132. 3341 1.75 44.45 1.14 0.S' 1½ 40 1 5 1.65 41,91 1.65 41.91 180 4512 L2 0.58 PA 1.82 1i2 1.88 1.43 32 46.23 49.23 31.15 045 2 2.W 2.16 207 119 50 54.83 54.8.4 5133 0.86 .15 7 50 225 5715 18$ 41.13 225 51.15 189 026 14 2 2.25 1.97 2.25 1.93 20 50 5735 50.04 57,15 0.88 1 1 ....iL_ 1.81 .45. Vi 1.75 HIS 1.81 1-4-9 1.39 .0.6& 511 2.25 57,15 2.02 32.31 2.25 51.15 2,06 0.9? 2$ 114 1.0 US IT 1.64 11 32 4J4 44.45 3234 0.14 1½ 1 1.88 TF 180 37 . 40 51.31 47.75 3(26 0.72 '2S 'TEO 2.25' 2.09 50 51.13 5134 $1.15 0.95 1 173 1.65 2.07 1.57 25 4.194 OR 5131 0.11 2 114 1.90 1.82 2.10 1.71 $0 1½ 40 ..32...... 48.26 46.23 .53.34 0.18 lW ...JL. 2.02 5:120 1.94 49 R 2.16 . 54,816 1.88 _051 2 2.25 2.16 2.2S 2.21 .59 51.15 ..J424 51.15 ....1.0.21_ A I 1.49 3125 1.49 31.85 188 41.15 1.53 0.69 . 20 1.60 40.64 1.60 40M 1.91 54104 1.63 0.14 • 25 r -17Y--i 43.94 43.94 51.31 -iiu 021 2 17 32 1.90 48.26 '190 43.24 2.10 5334 1.91 0.89 so "iW 2.02 2.02 2.16 2.12 40 . 51.31 5?,!! 54.86, 0.96 W 240 2.60 2.39 .15 ...JL.. 64.04 ._64.04 6031 1.43 HoOrml REDUCING TEE Dimensions Approx. Wl.Eadi _____ g C Err Cm, 21h 65 21h 65 20 1.7 44.20 liT 4420 2.32 59.93 167 [7? 'F 25. IN 41.50 1.87 41.5.0 W 6Ci20 2.84 1-29 1%" ...2L_ 2.04 5(8? 2.04 51.82 2.45 4Z 3.09 [40 1½ _4Q_ 2.16 216 _i 231 3,29 1.49 3 80 2.89 88 -- 3 $o -- ri1' 41.5 47.0 6429 _____ 169 _____ T 25 20 50.80 1W 50.80. F 61.56 1W [80 1W" 32 2.17 3512 211 .5511 2,14 6940 4.2a 02 1'W' j.... 2.29 58.?7 2.29 38.11 2.80 11.32 4.4 2.02 2 ....JIL. .2.52 6401 2.52 .. H O? 2.89 .13,41 4.90 2L ..Z., 2½ 2.83 2.83 259 5.69 4 100 4 164) ______ ,$_, V4Q 4940 84.61 __ 3,4. 1½ ._45_ 3.05 11.41 3.05 71.41 3.51 89.15 83 3.81 40 3.30 8397 TW 4.3.32 91.44 40 9.25 4.20 http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?I id=43 80 1/8/2014 Malleable Iron Screwed Fittings - Class 150 _c®uI 4> - LIT APPROVED idtk. W.P SM* R.c.sw4Iv4. Print Page 2 of 3 90' ELBOW Nominal site Dimension A Approx. Wt. Each &(kg) 0.69 0.06 6 1153 403 0.81 0.10 8 2051 0. OS 36 0.95 0.15 .10 2413 0.01 1.12 022 22.45 0.10 1.31 0.36 20 33.21 816 1 130 0.57 25 32.10 026 1% 1.15 0.87 32 #45 840 Ph 1.94 1.16 020 2 2.25 1.81 50 5116 0.82 24 2.10 323 65 43.58 1.41 3 3.08 4.82 80 /2.23 lit 4 3.79 8.41 100 161/ . 6 5.13 19.96 150 130.30 1 2.05 Dimensional: Fittings: ASME B16.3 Unions; ASME 816.39 Bushings/Plugs: ASME 816.14 Material: ASTM A..197 Galvanizing: ASTM A 153 (Hot Dip Galvanizing) Threading': ASME 81.20.1 Pressure Rating: Fittings: ASME B16.3 Unions: ASME 81 6.39 Bushings/Plugs: ASME 816.14 Pressure Testing. All malleable iron fittings ore tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron fittings and unions are UL listed and FM Approved, Brit,oh Stondord threading per BS 21 ovailobte upon mqueit. http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=43 70 1/8/2014 UM APVMM X.=* Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 1REDUCI NG I1.ELBOW NaimndSize Dhmfons Appiox.Wl.Each A 8 x 024 0.76 0.08 3:6 10.80 020 0.04 1 0.81 0.85 Oil lOw 6 20.51 21.59 0,05 0.88 0.90 0.13 lod 22.35 22.86 0.06 0.97 0,98 0.16 15:8 24.64 24.89 0111 1.04 1.03 0.19 15:10 28.42 8616 0.09 Lii 113 0.26 20X 10 20.45 2810 012 1.20 3.22 0.29 20A 15 30.48 30.99 013 11% 1.18 L26 0,35 25:W 29.91 37.00 0.14 1 x½ 1.26 1.36 0.42 25X ;5 3100. 3.5' . . Oil I x4 1.37 1.45 0.47 25:20 3412? 36.83 01 14x½ 1.34 1.53 0.54 32:15 34.04 388.6 0.24 16z/ L45 1.62 0.62 32:20 .94,83 41.1.5 (128 U6x 1 156 3.67 0.13 3205 40.13 4742 0.33 1Mx7h 1.38 165 0.65 411:15 35115 41.91 (U9 132 1.15 0.74 4020 38.61 44.45 0114 1½: 1 1.65 1.80 0.88 4& 25 41.91 45] 0.40 155:1% 1.82 1.88 1,03 4002 4413 47.15 047 2:55 1.50 1.89 0.93 501-15 *10 48.01 0.42 2x V4 1.60 1.91 1.04 50:20 1(164 50.04 0.41 lxi 1,13 2.02 3.28 50415 43?4 51.31 0.55 215 1.90 2.30 1.36 10:37 48.26 53.34 0.62 2:155 2.02 2.16 131 504O 51.31 5484 0.68 Dimensional: Fittings: ASME 816.3 Unions; ASME B 16.39 Bushings/Plugs: ASME 816.14 Material: ASTM Al 97 Galvanizing: ASTM A.353 (Hot Dip Galvanizing) Threading*, ASME 81.20.1 Pressure Rating: Fittings: ASME 81 6.3 Unions: ASME 1316.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron Fittings are tested For through wall porosity using an air under water process. Agency Approvals: All malleable iron fittings and unions ore UL listed and FM Approved. ' Brush Standord threoding per BS 21 ovoiloble upon requex?. REDUCI NG 90 ELBO' Mamm Size Oimensiomal A B ' hi. 6qn) W 255:155 2.16 231 220 65 r 40 6315 1.00 24:7 2.39 7.60 2.55 65x50 603! 66.04 1.16 3:2 732 7.89 3.35 80:50 44.01 13.41 152 3:255 2.83 2W 4.12 80:85 1189 15.95 1,51 4:2 2.12 3.43 5.01 180:50 69.09 81.17 40 330 3.60 6.65 180:80, 1 8362 9154 3.07 http://www.anvilintl.comfProductSearchlPrintProduct.aspx?1id43 71 1/8/2014 Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 WID AN'RDVEO wboI --.N iiiiJ!ti tlomtnoi Size Dimension A Approx. WI. Each 0.96 0.05 .6 24.3.6 002 1.06 0.00 6 26.l 004 1.16 0.12 10 2946 005 1,34 0.17 15 34,04 008 132 0.77 20 3841 011 1 1.61 0.43 25 4242 020 1% 1.93 0.65 37 48.02 02? 1½ 2.15 0.86 54.61 01? 2 2.53 135 50 6426 061 21h 2.80 2.33 65 1115 1.06 3 3.18 3.36 80 8011 1.52 4 3,69 539 100 8113 .254 Dimensional: Fittings: ASME B16.3 Unions ASME 816.39 Bushings/Plugs: ASME B16.14 Material: ASTM A.197 Galvanizing: ASTM A. 153 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME B16.3 Unions: ASME B16.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using an air under water process. Agency Approvals: All malleable iron Fittings and unions are UL listed and FM Approved. British Standard threading per BS 21 available upon request. http://www.anvilintl.comlProductSearchlPrintProduct.aspx?lid=43 74 1/8/2014 Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 I1u APPIOVED 100W. IN' 141VNWWNW*W0t S#.,R.. REDUCI NG COUi I'Ic NOMInOI Sz, Dimension A Approx, WI. Each 1.00 0.07 SX4 NO 0.03 1.13 0.09 106 2.10 004 1,13 0.10 1x8 28.10 005 1.25 0.13 iS6 31.15 006 1,25 0,13 3115 006 1.25 0.14 1S. 10 31.15 AN xl6 1.44 0.18 3438 OR 1.44 0.20 34.58 0 09 1.44 021 70,10 34.38 0.10 1.44 022 20,15 34.58 0.10 11 1,69 0.34 25x15 42.93 0.15 1.69 0.36 2520 4293 0.16 1%x4 2.06 047 32!5 5732 Gill ly4x% 2.06 0.51 32 jr 20 5232 0.73 1!4l 2.06 0.57 32425 $732 1)26 11h x 1h 2.31 0.62 4015 50.42 028 2.31 0.66 4020 5361 0.23 1½x1 2.31 0.73 4025 .58141 0.23 1xi14 2.31 0.80 40,32 58161 £136 Dimensional: Fittings: ASME 816.3 Unions: ASME 816.39 Bushings/Plugs: ASME 816.14 Material: ASTM Al 97 Galvanizing: ASTM A153 (Hot Dip Galvanizing) Threading*: ASME 81.201 Pressure Rating: Fillings: ASME B16.3 Unions: ASME 816.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using on air under water process. Agency Approvals: All malleable iron fittings and unions are UL Listed and FM Approved. 8r16sh Standard threading per 8$ 21 ovoiloble upon request. REDUCING COUPL hLL Honilnol Site Dimension A Approx. Wt. Etuh 2X% 2.81 0.94 505. ,. 11.37 0.43 2 x V4 2.81 0.99 SO 70 1131 0,43 2x1 2,81 1.03 302$ 7131 047 211h 2.81 1.17 50x32 11.31 0.53 2x14 2.81 125 50 g 44 71.31 051 2%xB4 3.25 1.81 65r32 V35 an 2½x155 3.25 1.90 4S40 QSS 026 - 2%x2 3.25 2.04 4550 . 8'235 . 0.93 3 x 1 3.69 2.48 2025 tV3 732 3z1A 3.69 80x22 9323 1.16 3x 11h 3.69 2.67 8010 9333 7.21 3x2 3.69 2.78 80x50 53.33 1.76 3 x 2 3.69 3.23 80165 9333 1.41 4 x 2 4.38 4.43 14V 4 50 fiLlS 701 4x21 4.38 4.81 10r45 111.25 2.21 40 4.38 3,29 100 g 80 fiLlS 2.40 http://www.anvilintl.com/ProductSearchlPrintProduct.aspx?lid=4379 1/8/2014 Print Page 2 of 3 CM tw W. 4; 44 Malleable Iron Screwed Fittings Class 150 um ROVO thO 01 WM1 wrMr 5w., RS*. t4omlncl Dimensions ___1._ Approx. A 8 C __________ Size WI. Each _____ &(W) t(nen2 kOzxt k(tiU lktl8) saw 1/4 0.44 0.28 0,38 0.04 ___L._ " R65 0,02 ______ Sam __ 16 0.48 0.31 0.44 0.06 !L._ 12.19 1 121 113 0.02 cow ½ 036 0.38 036 0.08 15 14.2) 9S 14.22 8.04 (oted 1 0.63 0.44 063 0.13 20 I&00 1.1.18 16.00. 0.05 cow 1 0.75 0.$0 0.81 0.20 25 1925 12.10 2031 0.09 ,., 'iW 0.80 0.56 0.94 0.32 32 2022 14.22 2388 0.15 cow 11h 0.83 0.62 1.13 0.43 40 2L20 ISIS 78,10 020 Cold 'u1uu 2 0.88 0.68 1.31 0.67 so N14 149 1 33.27 0.88 COWW 465 24 1.07 0.14 1.50 1.11 ii e ;o .a.ie ( ..A 1.13 OR 1.69 1.53 80 WO 2022 4223 029 go[ , r 4 Lfl 1.00 - 2.11 180 3W 25.40 - 1,23 . IW a" 6 1.40 1.25 - 4.00 ISO 3254 3115 - 185 Dimensional: Fittings: ASME B1&3 Unions: ASME B 16.39 Bushings/Plugs: ASME B16.14 Material: ASTM A-197 Galvanizing: ASTM A- 153 (Hot Dip Galvanizing) Threading*: ASME 81.20.1 Pressure Rating: Fittings: ASME 816.3 Unions: ASME 816.39 Bushings/Plugs: ASME 816.14 Pressure Testing: All malleable iron fittings are tested for through wall porosity using an air under water process. Agency Approvals: All malleable iron fittings and unions are UL listed and FM Approved. firithh 5andord threading per BS 21 ovaitobte upon request. h4://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=4378 1/8/2014 , w1 Print Page 2 of 3 Malleable Iron Screwed Fittings - Class 150 Itoiiinal Size Dimension A Approx. WI. Each 4e0 thkg2 053 0.03 6 13144 001 0.63 0.05 S i.co 002 0.74 0.07 10 18.80 - 003 ½ 0.87 0.11 15 2110 0.05 0.97 0.18 20 24,64 0.08 1.16 0.30 75 .2846 0.14 114 1.28 0.44 37 3151 0.20 1½ 1.33 0.55 334 025 2 1.45 0.85 50 36.83 0.21 21h 1.70 1,49 65 4118 0.68 3 1.80 220 80 45.12 1.00 3½ 1.90 3,02 90 4826 1.31 4 2.08 3.79 icti 5183 1.72 6 2.55 &77 150 64.17 1.98 - S.ççd hm Sdo4 ldOcMMxMJ. MATERIAL SPECIFICATIONS Dimensional: Fittings: ASME 816.3 Unions: ASME B 16.39 Bushings/Mugs: ASME B16.14 Material: ASTM A-i 97 Galvanizing: ASTM A153 (Hot Dip Galvanizing) Threading*: ASME 51.20.1 Pressure Rating: Fittings: ASME 816.3 Unions: ASME 816.39 Bushings/Plugs: ASME B 16.14 Pressure Testing: All malleable iron liftings ore tested For through wall porosity using on air under water process. Agency Approvals: All malleable iron fittings and unions ore UL Listed and FM Approved. 8nhh 5tondord threading per BS 21 ovailobte upon request. hq://www.anvilinti.com/ProductSearch/PrintProduct.aspx?lid=4373 1/8/2014 Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2" thru 8" pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21h" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650°F Finish - Mu. Galvanized. For Stainless Steel materi- als, order TOLCOTm Fig. 200WON. Order By - Figure number and pipe size Dimensions 'Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 31A 2% 400 11 3/4 3/8 8mm or 10mm 31,4 2½ 400 11 1 3/8 8mm or 10mm 3% 24 400 12 11/4 3/8 8mm or 10mm 3Y4 27A 400 13 1½ 3/8 8mm or 10mm 37A 27A 400 14 2 3/8 8mm or 10mm 41h 3 400 15 2½ 3/8 10mm 55A 41,4 600 27 3 3/8 10mm 57A 4 600 29 31h 3/8 10mm 73A 51/4 600 34 4 3/8 10mm 7% 5 1000 35 5 1/2 12mm 91/a 61/4 1250 66 6 1/2 12mm 10½ 6Y4 1250 73 8 1/2 12mm 131A 8Y4 1250 --- 136 Page 55 D OFFICEIMANUFACTURING FACILITY. 1375 SAMPSON AVE. CORONA, CA 92879. PH: 951.737.5599 - FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25 - Surge Restrainer Size Range - One size fits 314" thru 2" pipe. Material - Steel Function - Designed to be used in conjunction with TOLCOT111 Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the bank hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 6-2.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed pAly when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure.number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 D OFFICE/MANUFACTURING FACILITY • 1315 SAMPSON AVE. CORONA, CA 92819 • PH: 951.137.5599 • FAX: 951.131.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Component of State of California OSHPD Approved C .. Seismic Restraints System .' Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fg. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8' rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish - Dimensions 'Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F --750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 D OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA. CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 113 - Standard Hex Nut Size Range - Size l/4" thru 11/2U Material - Carbon Steel Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number size and finish Dimensions • Weights Width Width Rod Across Across Approx. Size Flats Points Thickness wt.iioo 1/4 7/16 1/2 7/32 .7 5/16 1/2 37/64 17/64 1.1 3/8 9/16 21/32 21/64 1.6 1/2 3/4 55/64 7/16 3.7 5/8 15/16 1 /a2 35/64 7.3 3/4 11/ 1 /16 41/64 12.0 7/8 1 /16 1/64 3/4 19.0 1 1/2 1/4 55/64 28.0 1'/4 1 /8 2/ 1/16 54.0 1'/2 21I4 21 /32 1/32 94.0 Fig. 115 - Flat Washer Size Range - Sizel/4° thru 11/21' Material - Carbon Steel Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number size and finish Dimensions • Weights Rod Size Outside Diameter Approx.Wt./100 1/4 3/4 .7 5/16 1 1.5 3/8 1/ 3.9 1/2 1/4 7.7 5/8 7.3 3/4 2 11.0 7/8 21/4 19.0 1 2/4 22.0 1'/ 3 26.0 1/2 3 /2 39.0 Fig. 114 - Heavy Hex Nut Size Range - Sizell4" thru 1I2" Material - Carbon Steel Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Dimensions • Weights Width Width Rod Across Across Approx. Size Flats Points Thickness Wt./100 1/4 1/2 37/64 15/64 1.2 5/16 9/16 21/32 19/64 1.7 3/8 11/16 51/64 23/64 3.1 1/2 7/8 1/6 31/64 6.5 5/8 1/16 1'/ 39/64 12.0 3/4 11/4 1/64 47/64 19.0 7/8 121/32 55/64 30.0 1 11/8 1% 63/64 43.0 1 /4 2 2/16 1/32 79.0 1/2 23/8 2/4 115/,131.0 Fig. 117 - Lock Washer Size Range - Sizel/4° thru 3/4" bolt Material - Carbon Steel Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number size and finish Dimensions • Weights Rod Size Outside Diameter Approx. Wt./100 3/8 11/16 .6 1/2 7/8 1.3 5/8 1/16 2.4 3/4 11/4 4.0 Page 63 Office/Manufacturing Facility. 1375 Sampson Ave. • Corona, CA 92879 • Ph: 951.737.5599 Fax: 951.737.0330 Customer Service • 800.786.5266 www.tolco.com STEEL - Pipe Hanger Approvals 8038957 - STR 1 3/3' Vertical 4 1500 035 4 1475 105 j 8037957 DSTR 11/2 38 '2 rtical 4 1500 035 4 1475 105 DSTR 516 IT - Vertical 4 1500 - 037' 4 - - 1475 105' 8045957 DST 516 3'8 Vertical 4 1500 188 4 1475 188 8046967 E80 3/8 VerSe-nI 4 1500 253 4' 1475 188 8055957 SWDR1 3/8 Horizontal 4 1500 037 4 1475 060' WiR 516 '8 - Horizontal 4' 1500 037 4 1475 060 8054957 SViDR 1-1/2 3,8r Horizontal 4 100 037 4 1475 060 57 SH-DSTR I 3/8' 17 Anqle off Vertic.al 4 1500 035 4 1475 - 105 8150922 XP 20 3'8 Vertical 2-1/2 853 327 4 1475 105 816922 XP 35 3/8 Vertic-al 3-1/2 1250 00 2 940 75 025' 8294922 8XP20 S V rh Iorapto45 2 750 027 2 635 029 - 8,Voruo8 32 - 10 060 2 65 2 8293957 SWXP 35 3/8' Horizontal 3-1/2' 1250 .060' ly FM C@u s WOOD. Pipe Hanger Approvals 8007957 GSJ 10- "3/8' Verticol - CPVO 1-1/2 300 1-11 2- 8020957 SWG 10 38 Horizontal CPVC 1-12 300 1-1/2 G S T_ 20 3'S' - V rtical 21/2 850 1-1/2 4 1475 11/2 8068925 GOT 20-SO 3/8 Vertical 2 1/2 850 1-112- to 11 O57 GST.'30, 18 Vertical 4 1530 1-1,2 4 - 1475 1-1/2 - 8009925 GST25-380 3'S Horizontal 4 1500 1-112 s,:23o 3/8 Horizontal 1'3-V2" 4' 1500 11/2 - 8021957 SWG 20 38 Horizontal 21 '2 3 1050 1-1!2 03925 J3 2-SS 3/8 Horizontal 2-1/2 850 1-1/2 8139957 SH-GST2O 18 17° Angle off Vertj 3 1350 1 112 4 1475 1-1/2' 8'i4167SHSTn30' 3/8 - 17'AnoIB off Vstrtjcl 4 15Q 1-1,2 4' 1475 -- I 1/2' CONCRETE - Pipe Hanger Approvals RJ &AM9ntJ - Size -. - Direction -e - T'Iriffiewrz ,gfl Load (Ibs) ' PSI Pipe Size - - - '8059957 CS120 - 3/8 'ertical - 4 1475 - 8061957 SWO 20 3'8 H riont I 4 1475 37 XP 20 3/8 VeiticrS - 2.1/2 - 850 -- 8150922 XP 20 3/8' Vertical 2-1/2' 850 Post-Pour Range II LWC 15 35 PCF (lbs/fl3) '-0 SWG 25-380 MaxImum pipe size In composite wood joist allowed by (/L is 3-1/2' SWG2S-380 Maximum Pipe sin ln wood dmbwm joist allowed byULls4' SWG 20 Maximum Pipe size In composite wood joist allowed by UL Is 2-1/7 SWG 20 Maximum Pipe size Inwood timber w joist allowed by UL is 3' - Sammys° and Truss-I Hai are registered trademarks of ITW Buildex and Illinois Tool Works, Inc. 02008 flW Ba/idea and usa/s Test Works, Inc. REV.0308 SSS40 - UL and FM tests were performed in compliance with NFPA 13 Standards, Fastening requirement Omen weight of water-filled schedule 40 pIpe plus 250 pounds. MMYS - 5 5iMM ,1- -- ------------- ---------------- www.itwbuildex,com 800-BUILDEX INTUMESCENT SEALANT APPLICATIONS SpecSeal® LCI Sealant has a broad application base designed to seal a wide variety of common penetrations in fight commercial and grouped residential construction. Penetrant types include insulated and non-insulated metallic pipes and tubes, non-metallic pipes and tubes, and common electrical service and power distribution, telephone, data, and TV cabling. This product is also used in conjunction with other SpecSeal® Products such as SpecSeal® Firestop Collars and Wrap Strips to protect larger plastic pipes. See Table A for a summary application list. PRODUCT DESCRIPTION SpeeSeal® LCI Sealant is a versatile and economical intumescent product intended for firestopping a wide array of applications in small commercial or grouped residential construction and other structures with similar applications. SpecSeal® LCI Sealant is available in a single grade that has excellent caulk- ing properties as well as high build properties on vertical or overhead surfaces. This single grade may be caulked (standard cartridge or bulk loaded), knifed or troweled. In addition, SpecSeat® LCI Sealant does not contain PCB's or asbestos. SpecSeal® LCI Sealant is storage stable (when stored according to the manufacturers recommenda- tions), and will not separate or shrink when dried. SpecSeal® Series LCI Sealant will adhere to all com- mon construction and penetrant materials and contains no solvents that might adversely effect plastic pipes or cable jackets. Economical: High performance without the high price! Highly Intumescent: Expands up to 8 times. Excellent Smoke Seal Water Resistant : Will not re-emulsify, when dry. Water-Based for easy installation, cleanup, and disposal. Acoustically Tested: Reduces noise transmission Safe Low VOC's, No Solvents, Non-Halogenated Paintable PERFORMANCE SpecSeal® LCI Sealant is the basis for systems that meet the exacting criteria of ASTM E814 (UL1479) and ASTM E1966 (UL2079) as well as to the lime-temperature requirements of ASTM El 19 (UL263). LCI provides up to a 2-hour fire rating for typical service penetrations through concrete or wood floors, concrete or masonry walls, as well as gypsum board walls (3-hour for metallic pipe, conduit and tubing). SpecSeal® LCI Sealant meets Class A finish requirements for Flame Spread and Smoke Development when tested in accordance with ASTM E84 (UL723). SpecSeal® LCI Sealant is also acoustically tested, demonstrating excellent sound attenuation properties. PHYSICAL PROPERTIES SYSTEM COMPATIBLE Color Red Odor Mild Latex Density 9.0lb/gal (1.08 kg4.) pH 9.0 In Service Temperature I~ 130°F (54°C) Flame Spread 0* Smoke Developed 5' STC Rating 62 (ASTM EOOIASTM 0919) VOC Content 0.ts (EPA Method 241A51M 03960) Shelf Life 2 yrs Volume Expansion lox Free Expansion Storage Temp. ~ 130°F(54°C) TdeASrME84MJ23laI l4%sifow'a)oo96lho FILL, VOID OR CAVITY MATERIALS FOR USE IN JOINT SYSTEMS AND THROUGH-PENETRATION F1RESTOP C us SYSTEMS. SEE UL DIRECTORY OF PRODUCTS CERTIFIED ® FOR CANADA AND UL FIRE RESISTANCE DIRECTORY. I APPROVB) 523 SPECIFICATIONS The tirestopping sealant shall be a water-resistant, intumescent latex sealant. The sealant when exposed to high heat or flame shall exhibit a tree expansion of up to 8 times its original volume. The tirestopping sealant shall contain no water soluble nor hygroscopic ingredients and shall be acoustically tested. The sealant shall be ULClassified and/or FM approved and tested to the requirements of ASTM E814 (UL1479) and shall meet Class A finish requirements when tested in accordance with ASTM E84 (UL723). SPECIFIED DIVISIONS DIV. 7 07840 Through-Penetration Firestopping DIV. 13 13900 Special Construction Fire Suppression & Supervisory Systems DIV. 15 15250 Mechanical Insulation - Fire Protection DIV. 16 16050 Basic Electrical Materials & Methods 99 Technical Service 1-800-992-1180 511 Product Data Sheet • Series LCt lntumesent Sealant • FOD-5062 06/2001 9-TI. www.stfflrestop.com Fig 1: METALLIC PIPES- Concrete1Masonry Floors & Walls Fig 2: INSULATED METALLIC PIPES - ConcretelMasonry Floors & Walls Steel Sleeve Metallic LCI Pipe Se alant Metallic LCI ICI Sealant __[IIIII"L.. Mineral Wool LCI Sealant Concrete Sleeve Floor Pipe ..,Seaiant _________ Steel \ I Concrete (Both Sides) I IRMi Sleeve \ Floor Mineral I' Wool mineral 4 Wool j±}Concrete Pipe Insulated teWall Insulated Wall Assembly Metallic Pipe UL System No. C-AJ-1353 UL System No. W-J-1098 UL System No. C-AJ-5138 F Rating: 3 Fir •l Rating: 0Hr F Raft 2Hr•T Raft l/4,3'4& 1 Hr F Rating: 2Hr•TRathg:3I4 or 1 Hr Sled or Iran Pipe: d2", Copper Poe: <4" Sled or Iron PDe:<8", Copper Ppe:<4 Steel or lrce Pipe: 6 Copper Pj,e:4" Annulus: 0" 102" Mt*s:0" " PeCaeei1ng: Max. mineral wool Insulation. Sealant Depth: 1/4" Sealant jj " Annulus: 1/4"lo 1-5 Sealant: 1/2" Forning Matmial:Ncxn4pmlaetal wool (2 1I4"Dlh) Forming: Noiu 4 pcf mineral w (do) Pipe Size 1.5 2.0 3.0 4.0 5.0 Diameter 0) Opening (in.) 6.0 7.0 8.0 10 12 14 26 TWO Sin. Pipe 0.11 0.5" 0.840 0.3 0.6 1.6 3.0 4.8 6.9 9.5 12.4 19.5 28.1 38.3 132.6 1.315 0.1 0.4 1.4 2.8 4.6 6.7 9.3 12.2 19.3 27.9 38.1 132.4 Vt MrI.kjt2 1.5" 1.900 1.1 2.4 4.2 6.4 8.9 11.9 18.9 27.6 37.8 132.0 5S MrI4*yby2.5 2.375 0.7 2.0 3.8 6.0 8.5 11.5 18.5 27.2 37.4 131.6 Mi*yt4 2.5" 2.875 0.1 1.5 3.3 5.4 8.0 10.9 18.0 26.7 36.9 131.1 3.500 0.7 2.5 4.7 7.2 10.2 17.2 25.9 36.1 130.3 3.5" 4.000 1.8 3.9 6.5 9.4 16.5 25.1 35.3 129.6 4.500 0.8 3.0 5.6 8.5 15.6 24.2 34.4 128.7 6" 6.625 1.1 4.0 11.1 19.7 29.9 124.2 8" 8.625 4.9 13.6 23.8 118.0 100.8 IMPORTANT NOTE: Na tablets for eatmaton purposes only. Consult UL Fire Resistance Directory or Sli Product &Apptcalion Guide for npedftc installation reiremenfa and Irnitaftons Meftic Ezthnatiei Table available upon request Fl 3: ELECTRICAL, DATA OR COMMUNICATIONS - Gypsum Walls Cable RCI Sealant LCI Sealant Bundle (Both Sides) [[j Non-Metallic oth Sides) Conduit Gypsu Wallboardm Gypsum Assembly Wallboard Assembly UL System No. W-L-3169 UL System No. W-L-2241 F Rating: 1.2 Hr.lRating: 1.4 and 1/4 F Rating: 1,2 Hr.TRating: 0, 1/4,1,1-314 Up to 4-1/2-cable bundle <2" Rigid PVC or ENMT, CPVC, ABS Annulus: 0t0 ½• Sealant 5/0" Annulus: 0-1". Sealant 5/8" TABLE A: APPliCATIONS TESTED AND CLASSIFIED FOR FIRE RESISTANCE Metallic Pipes including steel, iron, or copper pipe and tubing. Nonmetallic Pipes, Conduits & Tubing including PVC, CPVC, ABS, and PEX. Electrical & Electronic Cabling including service entrance, power distribution, computer, telephone, and television. Metal Ductwork including HVAC, bath and dryer vents. Insulated Pipes including heating, cooling, and condensation applications. Complete Wood Floor ttrestopping package for electhcal, plumbing, HVAC, telephone, and television. SD Product Data Sheet • Series 10 Intumescent Sealant • FOD-5062 06/2007 Technical Service 1800-992-1180 = www.stltlreStop.com Sill. INSTALLATION INSTRUCTIONS GENERAL: Areas to be protected must be clean and free of oil, loose dirt, rust or scale. Installation temperatures must be between 35°F (2°C) and 100°F (38°C Allow product to dry a minimum of 24 hours before exposure to moisture. SYSTEM SELECTION: Selection of an appropriate firestop system design is critical to the fire protection process. Space limitations preclude highly detailed Information pertaining to individual application systems. Please consult the Product & Application Guide as well as the UL® Fire Resistance Directory for additional Information. FORMING: Some installations may require forming as either an integral part of the system or as an option to facilitate installation. In systems where forming Is required, mineral wool baits with a minimum nominal density of 4 PCF (64 kgi3) are generally required. Cut forming material oversize to allow for tight packing. Position forming material to allow for the proper depth of fill material. FILL MATERIAL: SpecSeal® LCI Sealant may be installed by caulking using a standard caulking gun or from bulk containers using a bulk loading caulk gun, or by manually troweling using a mason's trowel or putty knife. If the sealant tends to pull back from a surface, clean the surface with a damp rag or sponge and reapply. Work sealant into all areas exercising care to eliminate voids or seams. The surface of the sealant can be smoothed using a putty knife dipped in water. Adding water to the sealant itself is not recommended. Sealant (when dry) may be painted using most non-solvent based paints. Wood Floor Lc,r..__J Sent Assembly LCI Wood Floor Sealant Assembly UL System No. F-C-1074 UL System No. F-C-5043 F Rating: 1 & 2 H °T Rating: ¼, ½ and 1 Hr F Rating: 1 & 2 Hr - I Rating: 1/4 and 1 Hr Steel, Iron or Copper: 4• Chase wall optional. Steel, Iron or Copper: 4 Annulus: 0to 1"• Sealant: 5/8-bottom, Wtop Pipe covering: V'Fiber Glass, Mineral fiber or AS/PVC • Chase wall optional. Annulus: 010 1° Sealant: 5/8 bottom, -top. In gypsum wallboard penetrations, apply a minimum cove bead of 1/4" (6 mm) at the interface of the penetrant with both exterior wall surfaces. SMOKE SEALING: In some applications including firestop collars, SpecSeal® LCI Sealant is recommended as a smoke seal. It is suggested In these applications that the sealant be applied t both sides of walls. In floor applications, a seating bead is suggested top and bottom. LIMITATIONS: SpecSeal® LCI Sealant is water- based and cures through the evaporation of water. Low temperatures as well as high humidity may retard drying. Non-porous or Impermeable backing materials, plates, or coatings may retard the drying process. Do not paint or seal in any way that pre- vents contact with air until sealant has dried through completely. This product has been designed to be safe with plastics and has been used extensively and successfully with a variety of different types of plastic pipes, tubes, and plastic cable insulations. Variations in these materials however, make it impossible to guarantee compatibility. STI strongly recommends that the user consult with the manufacturer of the pipe, tubing, or cable in question regarding any known sensitivities or potential restrictions before applying this product. I Fig. 4: BARE & INSULATED METALLIC PIPES - Wood Floor Assemblies I Insulated Metallic Sealant LCI 1JJj Metallic Pipe LCI Sealant I Fig. 5BARE& INSULATED METAWC PIPES - Gypsum wails I III LCI Sealant Metallic III Ill (Both Sides) Pipe 1,1 Insulated I I I I I I LCI Sealant Metallic (Both Sides) LCI Sealant (Both Sides) G AC Una walfboarcHr y sum Set Assembly III Ill Assembly UL System No. W-L-1222 F Rating: 1,2 Hr • I Rating: ¼, V4, 1 Hr Steel or Iron pipe: 8 Copper pipe: 4 Annulus: 0-to 2. Sealant: 5/8 Assembly JJL4_1]J UL System Nos. W-L-5121, W-L-5122 F Rating: 1,2 Hr•T Rating: 1 Hr & 1/4 Hr Steel or Iron pipe: 6 Copper pipe: 4 Pipe covering: Max. 2-fiber glass, WAD/PVC or 2minera1 fiber Annulus: 0t0 1-1/2'. Sealant: 5/8 UL System No. W-L-8025 F Rating: 1,2 Hr • I Rating: 1,4 Hr AC Line Set: Two copper tubes, one with 3/4 AB/PVC and thermostat wire Annulus: 0t0 1 • Sealant 5/8 9d STI. Technical Service 1800992i180 STI Produd Data Sheet • Series L(i intumescent Sealant • FOD-5062 06/2007 www.stltlrestop.com CAT. NO. DESCRIPTION LCI300 Sealant 10.1 oz Tube LCl305 Sealant 5 Gal Pail LC1320 Sealant 20 oz Sausage LC1329 Sealant 29 oz Quart Tube 18.2 Cu In (300 ml) 1,155 Cu In (19.0 Liters) 36 Cu in. (592 ml) 52 Cu in, (858 ml) MAINTENANCE No maintenance is normally required, however a periodic inspection of rated barriers is recommended to make sure that any new openings, modifications of previously installed firestops, or areas exhibiting physical damage, have been properly sealed or repaired. Subsequent sealing or repairs should be accomplished using SpecSeal® products per the original approved design. RETROFIT: When adding or removing penetrants, care should be taken to minimize damage to the seat. Reseal using SpecSeal® products per the approved design. NOTE: New penetrants of a different nature than the original design may require a totally new tirestop design or extensive modifications to the existing design. Reseal all openings as per the requirements of the modified design. TECHNICAL SERVICE Specified Technologies Inc. provides toll free technical support to assist in product selection and appropriate installation design. UL Systems, Material Safety Data Sheets and other technical information is available through the Technical Library at www.stilirestop.com. PRECAUTIONARY INFORMATION Consult Material Safety Data Sheet for additional information on the safe handling and disposal of this material. AVAILABILITY SpecSeat® Series LCt Sealant is available from authorized STI distributors. Consult factory or website for the names and locations of the nearest sates representatives or distributors. desSSSSeM The industry's most versatile sealant provides the tirestopping solutions for a wide range 01 combustible and noncombustible applications. Water-based intumescent sealant expands up to 8x! reaSps Three grades of intumescent wrap strips provide an unmatched combination of flexibility, economy, and expansion (up to 30Xl. Systems for plastic pipes including FR Polypropylene up to 8' trade size! SSC& RMStOp Easy to install, economical protection for ABS and PVC pipes (both solid and foam core) as well as CPVC, PVDF, and FRPP. LCC Collars are available up to 4 and SSC Collars are avail- able up to & trade size. Ftrestop Mortar Lightweight, versatile and economical! The best choice for large or complex installations. $SP Ftrestop Putty Available both in bar form and in pads, potty provides easy retrofit for through-penetrations and economical protection for electrical bones. Penstt® Silicones Sealants and loam for through-penetrations and construction joints. Unexcelled aging charac- teristics and flexibility. Etastomeric Joint Seats New economical products for sealing construction joints. Choose caulk or spray applied products tested to UL2079. CITY OF NEW YORK MEA 211-01-M IMPORTANT NOTICE: All statements, technical information, and recommendations contained herein are based upon testing believed to be reliable, but the accuracy arid completeness thereof is not guaranteed. WARRANTY Specified Technologies Inc. manufactures its goods in a manner to be free of defects. Should any defect occur in its goods (within one year), Specified Technologies Inc., upon prompt notification, will at its option, exchange or repair the goods or refund the purchase Noe. LIMITATIONS AND EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS EXPRESSED OR IMPLIED (INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE) AND UNDER NO CIRCUMSTANCES SHALL SPECIFIED TECHNOLOGIES INC. BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL PROPERTY DAMAGE OR LOSSES. PRIOR TO USE, THE USER SHALL DETERMINE THE SUITABILITY OF THE PRODUCT FOR ITS INTENDED USE, AND THE USER ASSUMES ALL RISKS AND LIABILITY FOR SUBSEQUENT USE. No statement or recommendation not oontained herein shall have any force or effect unless in an agreement signed by officers of seller and manufacturer. MADE IN THE USA -COPYRIGHT © 2008 SPECIFIED TECHNOLOGIES, INC. Specified Technologies Inc. 200 Evans Way. Somerville, NJ 08876 I Toll Free: 800-992-1180• F: 908.526.9623 ST1 Product Data Sheet • Series 1(1 Intumescent Sealant • FOD-5062 06/2007 Technical Service 1-80D-9921180 = www.stlflrestop.com .STI.