HomeMy WebLinkAbout2668 GATEWAY RD; ; FPC2018-0268; PermitI I 'k, 14:181:i I crqty of Carlsbad Print Date: 10/18/2021 Permit No: FPC2018-0268 Job Address: 2668 GATEWAY RD, CARLSBAD, CA 92009-1782 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel if: Track if: Valuation: $0.00 Lot if: Occupancy Group: Project if: #of Dwelling Units: Plan if: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check if: Fire Alarm Applied: 08/06/2018 Issued: 10/02/2018 0EV12023 Finaled Close Out: 05/26/2021 Inspector: Final Inspection: Project Title: UPTOWN BRESSI RANCH Description: UPTOWN BRESSI: BUILDING G -FIRE ALARM Applicant: RIVER FIRE AND SECURITY INC 8920 ACTIVITY RD. if STE SAN DIEGO, CA 92126-4458 (858) 752-6250 FEE AMOUNT FIRE Sprinkler Monitoring $371.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Submittal Package for: Building G Northwest Corner of Gateway Road & El Fuerte Street Carlsbad, CA 92009 River Fire and Security 8920 Activity Road, Suite J San Diego, CA 92126 Contains Cutsheets and CSFM Listings for: Fire Alarm Control Panel Remote Annunciator Cellular Communicator Document Cabinet Smoke Detector Manual Pull Station Input Module Horn/Strobe Fire Bell D 0 IFP-75B Honeywell I Farenhyt Series Intelligent Fire Alarm Control Panel IFP-75 / IFP-75B The IFP-75 (red) and IFP-75B (black) are intelligent analog/ addressable Fire Alarm Control Panels (FACP). IFP-75 has a single line circuit (SLC) loop for connecting addressable detectors, which can support 75 IDP/SK sensors and 75 IDP/SK modules or 75 SD devices per loop. For System Sensor devices the overall point capacity to a maximum of 150 points per panel, or for Hochiki devices the overall point capacity to a maximum of 75 points per panel. IFP-75 has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. To network panels together use the SK-NIC network interface card. Copper wire or fiber optic cable panel connectivity can be used within the same networked system. IFP-75 has a built-in dual-line digital and IP communicator with an optional cellular communication module, Form C trouble relay, and two programmable Form C relays. IFP-75 has powerful features such as detector sensitivity, day/nightthresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert. The IFP-75 supports a variety of devices, including PA- 2000, P4-1000 or 84-100 remote annunciator, 5824 serial/ parallel printer interface module (for printing system reports), RPS-1000 power module, and lOP, SK or SD devices. FEATURES & BENEFITS Network support for up to 32 Sites Built-in support for up to 75 IDP/Sl< detectors and 75 IDP/SK modules or 75 SD SLC devices Four line LCD display with 40 characters per line Available in a red or black cabinet IFP-75 can be surface or flush mounted Built-in USB interface for programming Programmable date setting for Daylight Saving Time JumpStart Au to Programming feature for easy programming Built-in dual phone line, digital alarm communicator! transmitter (DAd), IP or optional cellular technologies Network card allows copper network connection with a multi-mode or single-mode fiber connection Option Firmware can be upgraded in the field Supports up to four SWIFT wireless gateways. Each gateway can have up to 49 wireless devices Supports Class B (Style 4) and Class A (Style 6 or Style 7 configuration for SLC, and SBUS Built in synchronization for appliances from AMSECO, Gentex', System Sensor . and Wheelock Reports events to central station by point or by zone IFP-75 Technical Specifications SPECIFICATIONS Physical: Overall Dimensions: 15.12" H x 12.71W x 3.33" D Weight: 25 lbs. Color: Red or Black Environmental Operating Temperature: 32°F to 120°F (0°Cto49°C) Humidity: 0 to 93°/s relative humidity (non- condensing) ELECTRICAL: IFP-75 Primary AC: 120 VAC c; 60 Hz, 900mA Total Accessory Load:2.54 @ 27.4 VDC power-limited Standby Current: 165 mA Alarm Current: 310 mA Battery Charging Capacity: 7 to 35 AH Battery Size: 7 AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. APPROVALS NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service Other Approvals: UL Listing; CSFM (pending); COA (pending); OSHPD (CA) (pending), FM (pending) APPROVED RELEASING SOLENOIDS Asco T8210A107 24VDC 3Amax 0 H Asco 8210G207 24VDC 3Amax 0 H COMPATIBLE DEVICES See the data sheets listed below for a complete listing of the IDP, SK, SWIFT or SD devices. 350361 - IDP Device Protocol data sheet 53623 - SK Device Protocol data sheet 350360-SD Device Protocol data sheet 351615 & 351617- SWIFT devices ORDERING INFORMATION IFP-75 - Intelligent Fire Alarm Control Panel. Red IFP-75B - Intelligent Fire Alarm Control Panel Black SBUS ACCESSORIES RA-2000, RA-1000, RA-1000R, RA-100, RA-2000GRAY- Remote annunciators. RPS-1000 - Power Supply 5496- NAC Expander 5824- Serial/Parallel Module 5880- LED I/O Module 5865-3/-4 - LED Annunciator 6883- Relay Interface MISCELLANEOUS ACCESSORIES SKSS-3 - Software Suite. Provides programming, upload/download and event reporting RBB - Remote Battery Box Cabinet. Use for backup batteries up to 35 AH. Dim: 16W x 10" H x 6" 0 SK-SCK - Seismic Compliance Kit SK-NIC - Network Interface Card SK-NIC-KIT- Network Interface Card in Cabinet SK-FML - Multi Mode Fiber Card SK-FSL - Single Mode Fiber Card CELL-MOD - Cellular Communicator in Plastic Enclosure CELL-CAB-SK - Cellular Communicator in Metal Enclosure with lock and key For a complete listing of all compliance approvals and certifications, please visit www.farenhyt.com, Microsoft. Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. All other trademarks are the property of their respective owners. This document is not intended to be used for nstallation purposes. We try to keep our product information up-to date and accurate. We Cannot coverall specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, Please call 800-446-6444. For more information www.farenhyt.com Honeywell 12 Clintonville Road Northford, Cl 06472 800-328-0103 www.farenhyt.com Dec 351605lRev Al 03/17 6 2017 Honeyweil International Inc, Honeywell Farenhyt Remote Annunciator RA-1 000 The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels (FACPs). The RA- 1000's keypad and display match the built-in annunciator of the IFP-1 000 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on as alarms, supervisories, troubles, system silenced and AC power losses occur. Features 80-character backlit LCD display (4 lines with 20 characters on each line) Tactile and audible feedback Accepts user codes or fire fighter's key Larger keypad buttons for system reset and silence RS-485 interface to panel Operation and appearance is identical to IFP-1000 built-in annunciator Install up to eight RA-1000s per FACP Support for simultaneous use of multiple RA-1000s On-board piezo sounder audibly indicates alarms, troubles, and supervisories Five status LEDs for alarm, supervisory, trouble, silence and AC power conditions Available in red or light gray Wiring lengths up to 6000 ft. from the FACP (depending on wire gauge and number of devices on SBUS) UL listed, complies with NFPA 72 CSFM approved MEA D SILENT KNIGHT by Honeywell Agency Listings ; 429-92-E Vol IX US MEA RA-1 000 Installation The RA-1000 can be surface or flush mounted. Use the optional trim ring for surface mounts. When flush mounting an electrical box is optional. If using an electrical box, use a 4S, single-gang, or double-gang box. Compatibility The RA-1000 is compatible with the following FACPs: IFP-11000ECS Emergency Communication System with Fire Alarm Control Panel lFP-100ECS Emergency Communication System and Fire Alarm Control Panel lFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel lFP-50 Intelligent Fire Panel P/N 350071 Rev D Copyright © 2012 Honeywell International Inc. FleXpUtTM is a Trademark of Silent Knight Jumpstart® is a Registered Trademark of Silent Knight IFP-1 000 FACP RA-1000 RA-1000 RA-1000 woo mom Up to 8 RA-1000 per system 80-character backlit LCD display (4 lines with 20 characters each) Wiring lengths up to 6000 ft. from the control panel Specifications Physical Height: 7.4" (18.8 cm) Width: 9.1" (23.1 cm) Depth: 1.5" (3.8 cm) Shipping Weight: 2.8 lbs (1.3 kg) Color RA-1000R: Red RA-1000: Gray Electrical Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Approvals NFPA72 UL Listed; CSFM 7170-0559: 135; MEA429-92-E Vol. IX; FM Approved Ordering Information RA-1 ODOR Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. RA-1000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 58601R Red Trim Ring. For surface mounting. 5860TG Gray Trim Ring. For surface mounting. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0503 Page 1 of 2 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Silent Knight Model lFP-75, Fire Alarm Control Unit, automatic, manual, local, remote station (PPU), central station (PPU), releasing (water deluge only). Model IFP-75 System Components: 5860 Remote Annunciator 6855 Remote Annunciator 6860 Remote Annunciator 5496 NAC Expander 5880 LED I/O Module 5865-3 Remote LED Annunciator 5865-4 Remote LED Annunciator 5883 Relay Interface 5824 Serial/Paralell Printer Interface Module 5895XL Power Supply SK-NIC Network Inerface Card SK-N IC-KIT Network Interface Card in Cabinet SK-FML Mulit Mode Fiber Card SK-FSL Single Mode Fiber Card CELL-MOD Celullar Communicator in Plastic Enclosure CELL-CAB-SK Cellular Communicator in Metal Enclosure with Lock & Key RBB Remote Battery Box (16"WX10'HX6"D) SK-SCK Seismic Complaince Kit RATING: Primary Operating Power Supply: 120VAC, 60HZ, 1.5A Secondary Operating Power Supply: 24VDC, 3.1A, 35Ah INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a commercial fire alarm control unit for use with separately listed initiating and This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0503 Page 2 of 2 indicating devices. Refer to listee's Installation Instruction Manual for details. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Rv' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Dec From Tyco Security Products Ensure your installations are future-ready, with LTE Features That Make a Difference: Uses LTE network for high- speed, reliable and low-cost communications to an IF receiver Automatically switches to 3G (HSPNHSPA+) if LTE service is not available Compatible with control panels that communicate using Contact ID or SIA (300 baud) formats Full event reporting 4 on-board inputs with NC, NO or SEOL supervision 4 on-board outputs (open collector) Activation and initialization via website or mobile interface provided by C24 Communications View communicator status directly from your mobile phone to support on-site or remote troubleshooting Compatible with Sur-Gard® System l-IP/ll/lll/IV/5 monitoring station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery UL 864 listed CSFM listed Due to rapidly-evolving cellular technologies, 2G/3G network sunsets are already on the horizon - with some having already been completed. Now's the time to adopt and adapt. Switch to LTE today, to offer customers long-lasting investment protection, and reduce your future truck rolls. The LE401 OCF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System I-IF/II/lll/IV/5). The LE401 OCF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SlA (300 baud) format. The LE401 OCF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010, 2013, and 2016 editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFFA72 2010) or 1 hour (NFFA72 2013/2016) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The LE401 OCF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the LE401 OCF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the FSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. Dec From Tyco Security Products In instances where the control panel does not support Contact ID or SIA (300 baud), the LE401 OCF has inputs pre- set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IP linecard of the monitoring station receiver (Sur-Gard System l-IP/11/111/lV/5). Activating & Initializing the Unit Activating and initializing the LE401 OCF can be done using the website interface provided by C24 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance C24 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost allocated to maintenance. UL Listing The LE401 OCF is UL listed under File S4019, Listing guide UO)O<, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the LE401OCF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013/2016 guidelines the LE401 OCF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the LE401 OCF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The LE401 OCF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: LE401 OCF-AT .............. Universal Wireless Commercial Fire Alarm Communicator Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the LE401 OCF requires use of the 4MB (NFPA72 2010) or 5001<13 (NFPA72 2013/2016) rate plans to support the supervision requirements. Specifications Dimensions ................................................ 11-1/2 x 10 x3" (290 mm x 254 mm x 75 mm) InputVoltage.............................................................120 VAC Current Draw ..............................................200 mA (standby) 400 mA (transmitting) Operating Environment ................32° to 120° F (0° to 49° C) Weight...........................................................12.8 lbs (5.8 kg) Optional Acessories Model Description LTE-1 5ANT 15 ft extension antenna LTE-25ANT 25 ft extension antenna LTE-50ANT 50 ft extension antenna CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1273:0506 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Security Controls95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 Email: dnita@tycoint.com DESIGN: Model LE401OCF LIE interface. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a interface for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. 01-11-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Fire Document Box The FDB is the perfect fit to meet the demanding code requirements today. NFPA 72 10.18.2.1.2.8 states that a cabinet must be "prominently labeled 'FIRE ALARM DOCUMENTS'." An internal galvanized sleeve holds the documents safely and securely. The sleeve is easily removable to allow storage of a 1.5" 3 ring binder or other media. The galvanized sleeve also contains 2 hooks for key rings or thumb drives, a place for several business cards, a cutout for a 1.4 Oz. can of test gas and a slot where a standard CD "jewel" case can be stored. Access to the documents is via a high security lock with a 3/4" barrel. Standard Features: Overall Dimensions are: 12" Wide x 13.1" High x 2.25" Deep 3/4" barrel lock to secure door Piano Hinged Door w/Notes Sticker Removable document holder can hold 1" of 8.5" x 11" paperwork Powder Coat Red Finish 16 Gauge CRS construction Embossed: Key Ring Hooks Business Card Holder CD Case Slot 1.4 Oz. can of detector smoke Custom screening with your logo Key Ring Hooks Detector Smoke Business Card Holder CD Jewel Case installation & Inspection Notes WAIIIIIIWW - NFPA Made In U.S.A. ISO 900i --1 REGISTERED COMPANY ADA L Lock w/ 3/4" barrel Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2008 ED0447 LT10505 Rev.A Oct. 2010 1/2 No Excuses, Just Solutions! ,YESPACE AGE ELECTRONICS, INC. Specifications: The Fire Document Box (FDB) shall be constructed of 16 gauge cold rolled steel (CRS); it shall be painted with a durable red powder coat paint. The front door shall be lettered with the words "FIRE ALARM DOCUMENTS" in White indelible letters 1" in height. The door of the FDB shall be locked with a keyed lock, 3/4" barrel. The cabinet shall contain a 16 gauge galvanized CRS sleeve. This sleeve shall allow for the storage of 1" of paper, test and inspection records, manuals and other important documents. The sleeve shall also facilitate the hanging of key rings and thumb drives (for data storage) along with business cards and space for a CD "jewel" case. The unit shall also contain a 1 .4oz can of smoke detector test gas. Adheared inside the door shall be a "Notes" label for the recording of valuable information such as AHJ approvals, various system codes and the location of hard to find devices. If so desired, the internal sleeve (held in by 2 wing nuts) may be removed and the space used to insert a 1.5" 3 ring binder. rotc I015UYr wvt kE('Oiti' OF ctt%IPt ETI()5 TI1 C 1%qKC.II(I' kPtIII r QI'IR III. FIEVAMR111111 11-1 AStFUPftI.kF ton vlvr::, 'H RI 11111 NOTES: System Access: System Level Code - Ev25l3 UlOSO! ReVS FOB Do Sticker .I 3ec.AckEkVcck. ckOrccVcev,ed St.IqMAOIICS 9t-4t723 Notes Sticker inside FDB Door Ordering Information: Part # Description SSU00672 FDB Fire Document Box SSU00673 FDB Custom Logo/lock (ask for Form FD10498 to order custom box) CKI Replacement 1.4 Oz Test Gas This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0447 LT1 0505 Rev.A 2/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TC1-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFi, IFX/A and IFX/D enclosures. Models ACE-1 1, ACE-1 2 and ACE-1 3, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct VI operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal IDP-Photo, IDP-Photo-T and IDP-PhotoR The IDP-Photo is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the IDP-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors. Features Sleek, low-profile design Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the lDP-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3601 visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (System Sensor® PN RA100Z) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed DSILENT KNIGHT by Honeywell MEA US L 225-02-E Vol. V IDP-Photo (Base not Included) Installation The IDP-Photo and IDP-Photo-T plug into a compatible IDP-series detector base. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors Compatibility The IDP-Photo, IDP-Photo-T and IDP-PhotoR are compatible with the following IDP-series detector bases: B21OLP 6" Mounting Base B501 4" Mounting Base B224B1 6" Isolator Base B224RB 6" Relay Base B200SR 6" Sounder Base The IDP-Photo, IDP-Photo-T and IDP-PhotoR are compatible with the following FACPs: IFP-2000 I RPS-2000 Intelligent Fire Panel IFP-2000ECS Emergency Communication System with Fire Panel lFP-1000 I ECS Intelligent Fire Panel IFP-100 I ECS Intelligent Fire Panel IFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel P/N 350280 Rev G Copyright © 2015 Honeywell International Inc. I I..................................................................... Wiring IDP-Series Detector Mounting Bases Wiring IDP-Series Detector Mounting Bases Specifications* Ordering Information Physical IDP-Photo Photoelectric Smoke Detector Height: 2.0" (5.0 cm) lDP-Photo-T Photoelectric Smoke Detector with Diameter: 4.1" (10.4 cm) installed in B501 base Thermal (135°F) Electrical IDP-PhotoR Photoelectric smoke detector, remote Operating Voltage: 15-32 VDC test capable, for use with DNR (W) duct SLC Standby and Alarm Current: 300 pA smoke detector Accessories Environmental Operating Temperature RA100Z Remote LED Annunciator. IDP-Photo: 321 - 120°F (0°C - 49°C) XR2B Detector Removal Tool. A removal and lDP-Photo-T: 321 - 100°F (0°C - 38°C) replacement tool for IDP plug-in detectors. Includes the T55-127-000. Humidity: 10% - 93% non-condensing M02-04-01 Detector Test Magnet. Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135°F M02-09-00 Test Magnet with Telescoping Handle. (57°C) XP-4 Extension Pole for XR2B. Extends from Velocity: 0 —4000 fpm (0 - 20 m/sec) (suitable for 5— 15 ft. installation in ducts) T55-127-000 Detector Removal Head. lDP-Photo Insect Screen Hole Size: 0.016" (0.41 mm) BCK-200B Black Detector Kit. For IDP-series nominal detectors. * Unless otherwise noted, specifications apply to IDP-Photo and IDP-Photo-T. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications KNIGHT are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. by Honeywell For Technical Support, Please call 800-446-6444. www.farenhyt.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0149 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 464-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywell.com DESIGN: Models IDP-PHOTO, IDPPHOTOR*, IDP-PHOTO-T, lDP-ACCLIMATE, SK-PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model lDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models IDP-PHOTO and IDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. 3242-1653:209) and DNRW (OSFM Listing No. 3242_1653:210)*. Models 5K-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW (OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. 02-01-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt Addressable Single Action and Dual Action Pull Stations IDP-Pull-SA & IDP-Pull-DA The IDP-Pull-SA is a single action pull station requiring only one motion to activate the station. The IDP-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight IFP-series fire alarm control panels (FACPs). Features Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) Meets ADA requirement for 5 lbs maximum pull force to active Shell, door, and handle molded from durable LEXAN® Reliable analog communications for trouble-free operation Braille text on station handle Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled Rotary address switches for fast installation UL Listed, including UL 38, Standard of Manually Actuated Signaling System Installation The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double- gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor PN BG-TR) trim ring if the station is being semi-flush mounted. SILENT KNIGHT by Honeywell Agency Listings MEA 67-02-E Vol. IX For IDP Pull DA IDP-Pull-SA IDP-Pull-DA Compatibility The IDP-Pull-SA and lDP-Pull-DA are compatible with the following FACPs: IFP-2000/RPS-2000 Intelligent Fire Panel IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel P/N 350286 Rev E © 2010 Honeywell International Inc Compatible FACP Wiring IDP-Pull-SA & IDP-Pull-DA Pull Stations Specifications* Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Operating Current (LED flashing): 300 jA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 321 - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Ordering Information IDP-Pull-SA Single Action Pull Station lDP-Pull-DA Dual Action Pull Station Accessories BG-TR Optional trim ring. SB-I/O Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to lDP-Pull-SA and IDP-Pull-DA. D SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472- by Honeywell 1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0157 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Model IDP-PULL-SA manual pull box. Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 09-08-09 fm TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Farenhyt IDP-Minimon The IDP-Minimon is a compact and light weight addressable monitor module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Minimon acts as an interface to contact devices, such as waterfiow switches and pull stations. The IDP-Minimon supports Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features Single contact monitor Small and lightweight size allows for flexible mounting options Support for Class B wiring Fully supervised Rotary address switches for fast installation Analog communications UL Listed Installation The IDP-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. D SILENT KNIGHT by Honeywell Agency Listings Ut MEA 457-99-E Vol. V IDP-Minimon Compatibility The IDP-Minimon is compatible with the following FACPs: lFP-2000 / RPS-2000 Intelligent Fire Panel lFP-1000 / ECS Intelligent Fire Panel IFP-100 / ECS Intelligent Fire Panel lFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel P/N 350279 Rev F Copyright © 20131-loneywell International Inc Other Devices Wiring the IDP-Minimon Specifications Physical Height: 1.3" (3.3 cm) Width: 2.8" (7 cm) Depth: 0.5" (1.3 cm) Shipping Weight: 1.2 oz (37 g) Electrical Operating Voltage: 15 - 32 VDC Standby Current: 375 pA; 600 pA max (communicating, IDC shorted) End-of-Line Resistance: 47K Initiating Device Circuit Wiring Resistance: 1,5002 max SLC Loop Resistance: 402 max. Wire Length: 6" mm. Environmental Operating Temperature: 32°F - 120°F (0°C - 49°C) Humidity: 10% - 93% non-condensing Ordering Information IDP-Minimon Miniature Monitoring Module This document is not intended to be used for installation purposes. We try to keep our SILENT product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 It Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell 800-446-6444. www.farenhyt.com Made in the U.S.A. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0155 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev@honeywell.com DESIGN: Models IDP-Relay-6, SK-Relay-6, relay module, IDP-Control-6, SK -Control-6, supervising control module, IDP-Monitor-10, SK-Mon-10, input monitor module, IDP-Zone-6, SK-Zone-6 six zone interface module, IDP-Monitor, IDP-Minimon, IDP-Zone, SK-Monitor, SK-Minimon, SK-Zone monitor modules, IDP-Control, lDP-Relay, SK-Control, SK-Relay, control modules, IDP-Monitor-2, SK-Monitor-2, dual monitor modulesand *IDP..RELAYMON..2 *SK..RELAYMON..2 with 2 input/2 output relay modules. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: If an external power supply is used for Model SK-Zone-6 and IDP-Zone-6, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. XLF: 7300-0028:0219 *Rev. 10-25-11 mt This listing is based upon technical data submitted by the applicant. the test results and/or other data but does not make an independent verification CSFM Fire Engineering of any claims. staff has reviewed This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR® F Indoor Selectable- Output Horns, E Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: - 15, 30, 75, 95, 110,135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices Compatible with MDL3 sync module Listed for wall mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING & A1111.1U1 O;~ LISTED S552 FM app'oved except 7125-1653 0504 S40 Or ALERT rrrodeis 7135-1653 0503 3057303. 3057072 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 1/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/9-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, [-Series products, when used with the Sync.Circuit'' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor [-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor [-Series Model listed to U[ 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shalt be a System Sensor Sync-Circuit model MDL3 listed to U[ 464 and shall be approved for fire protective service. The module shalt synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (000 to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR'2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.61 x 4.7'W x 1.91 D (143 mm Lx 119 mm W x 49 mm 0) Compact Wall-Mount Dimensions (including lens) 5.26"L x 3.46" W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6'[ x 4.7'Wx 1.25'D(143mm Lx 119 mm W 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45W x 1.25" D 033mm Lx 88mm W x 32mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 cd and 30 Cd. UL Current Draw Data Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, (15-115 cd) Candela Range Coded 3.1 KHz Coded High High 43 42 47 43 54 54 DC Input 8-17.5 Volts 15cd 30cd 16-33 Volts lscd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.lKTemporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes 5 3.46 1.25 .27 00 itlilifi OoGoOaOoOe o0o,e0o10 Compact Horn = Horns L-Series Dimensions —1.91 3.46 1.25 5.27 _ Compact Strobe! Horn Strobe -4.70 —s - 1.91 1.25 .w. 5T Li Strobe / Horn Strobe L-Series Ordering Information Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red HAL Horn, Red P2WL 2-Wire, Horn Strobe, White HWL Horn, White P2GRL 2-Wire, Compact Horn Strobe. Red HGRL Compact Horn, Red P2GWL 2-Wire, Compact Horn Strobe. White HGWL Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBRL Wall Surface Mount Back Box, Red Wall Strobes SBBWL Wall Surface Mount Back Box, White SAL Strobe, Red SBBGRL Compact Wall Surface Mount Back Box, Red SWL Strobe, White SBBGWL Compact Wall Surface Mount Back Box, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have "ALERT" marking on cover 3825 Ohio Avenue • St. Charles, IL 60174 ...$ Phone: 800-SENSOR2 ©23'7SpslerrrSensor, Fax: 630-377-6495 Product spec'codo's uso1uctto change wdhoa: notice, Vrsrlsyatee'ce-sor.corrr for current product informut on. nclucrng he latest version of "is data sheet sensor,com AVOSB6503 • 03/17 SENSOR" www, system CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL @ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135—AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.KireyevhoneyweIl.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walllrim Rings: *TR2 and TR-2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listees data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listees printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listees Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER The Symbol of Protection These vibrating type bells are designed for use as lire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. BELLS PBA-AC & MBA-DC UL, ULC, and FM Approved Sizes Available: 6' (150mm). 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note I) -40° to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproofbackbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -300 to 150°F (-340 to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .1 2A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .1 2A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10 (250) 24VDC MBA- 10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .1 7A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10(250) I20VAC PBAI20I0 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-l. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, • Phone: 866-572-3005/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. 45400776 - REV V-I PAGE I OF 2 01/13 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance (E)POTTER The Symbol of Protection Bells Dimensions Inches (mm) Fig. I BELLS PBA-AC & MBA-DC Wiring (rear view) Fig. 3 A.C. BELLS WHITE (IN) WHITE (OUT) FROM CONTROL PANEL OR PRECEDING BELL B BLACK (OUT)LACK (IN) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRE!) USE [N AND OUT LEADS AS SHOWN, NOTES: I. WHEN USING AC BELLS. TERM INATEEACH EXTRA WIBESEPARATEI.YAFTER LASTBEI,L. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. I))VG I6.I XWC.I- IN.! DWG) 70-2 4 14" (lOS) Installation I. The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90' AFF and not less than 6' below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). IWOM -I Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y-I PAGE 2 OF 2 01/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0328:0119 Page 1 of 1 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Models 513624-153075, 5B624-75110, PBA246, PBA248, PBA2410, PBAI206, PBAI208, PBA12O1O, *pBD..126 *pBD_128, *pBD.1210 *pBD.246 *PBD.248 * PBD-2410 vibrating bells. Suitable for outdoor use when used with Model BBK-1 backbox. Models are AC or DC powered and available in 6", 8" and 10'. Models MBA-6, -8 and -10 bells, suitable for outdoor use when used with Model BBX-1 backbox. Refer to listees data sheet for detailed product description and operational considerations. RATING: PBA-246, -248, -2410: 24 VAC PBA-1206, -1208, -12010: 120 VAC MBA-6, -8, -10: 12or24VDC *pBD.426 -128, -1210: 12VDC, .12A *pBD.246 -248, -2410: 24VDC, .06A INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. *Revision 01-31-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division