Loading...
HomeMy WebLinkAbout4020 JAMES DR; ; AS160122; Permit10/21/21, 2:44 PM AS160122 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS160122 Job Address: 4020 JAMES DR Status: ISSUED Permit Type: SPRINK Applied 5/5/2016 Parcel No: 2070226500 Approved: 5/27/20.16 Lot #: 0 Reference No.: . Issued: 5/27/2016 PC #: Inspector: Project Title: JAMES RESIDENCE SFft INSTALL NEW FIRE SPRINKLER SYTEM Applicant: INNOVATIVE FIRE PROTECTION INC STE 101 8779 COTTONWOOD AV SANTEECA (619) 593-8200 (619)593-9133 Owner: MARTINET FAMILY TRUST 04-06-00 1236 WASHINGTON ST KEY WEST FL Fees ($) Add'l Fees ($) Total ($) Balance ($) 303 0 303 . 0 1/1 DOMESTIC WATER- LINE 3 11 10 4 0 D. 16" 12 0 SEE DETAIL BRASS OR .W-3 COPPER 10 I PRIVATE PUBLIC 8 NOTES: REFER TO DRAWING W-3 FOR SPECIFICATIONS OF 9 17.5" INSTALLATION OF SERVICE LINE AND APPURTENANCES. I DISTRICT TO SET METER AND BALL VALVE, ALL OTHERS TO BE INSTALLED BY CONTRACTOR. I 3.' DOMESTIC WATER LINE MATERIAL WILL BE IN 6 CONFORMANCE TO CODE. 4. ALL 2" OR SMALLER COPPER JOINTS SHALL BE PRESS—CONNECT IN CONFORMANCE WITH SPECIFICATIONS. t SIDEWALK SEE W-3, W-8, 07 OR W-9 ITEM DESCRIPTION I SPEC/DWG cl)COPPER, ITYPE 'K' , SOFT] 15057 30 LB. ZINC ANODE LEAD WIRE I W-25 2" X 1" COPPER TEE (PRESS—CONNLCT) 1"90'_ COPPER _BEND _(PRESS—CONNECT) NOT USED 1" ANGLE METER STOP #37 ARMORCAST_ METER _BOX _(OR _EQUIVALENT ) 1" BALL VALVE 1" WATER METER BY DISTRICT BRASS UNION I AS 1 60122 4O2O JAMES DR 8 9 2" FIRE APPROVED _SYSTEM _WATER _LINE _(SIZE _TO_BE_ _BY_ _MARSHAL) FIRE I 1" DOUBLE CHECK VALVE WITH SHUT OFF VALVES (LEAD FREE) I REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT /4 - 02 /16 IDISTR-ICT 1 02/16 I' DOMESTIC WATER SERVICE'CONNECTION WITH FIRE SPRINKLER SYSTEM ENGINEER DA TE STANDARD DWG.NO. W - A INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR JAMES RESIDENCE 4020 JAMES DRIVE CARLSBAD, CA 92008 FLLE NUMBER: C6210 DATE: MAY 19, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 144 sq. ft. COVERAGE PER SPRINKLER: 20'X20'-400 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 1 sprinkler TOTAL SPRINKLER WATER FLOW REQUIRED: 21.0 gpm TOTAL WATER REQUIRED (including hose) : 26.0 gpm FLOW AND PRESSURE (@ BOR) : 21.0 gpm @ 29.0 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: SAN DIEGO COUNTY FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. B CD In 0 --1 (I) 0 0 0 WE SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/19/2016R0GRAM FILES\HRS SYSTEMS\JP CALCS\JAMES RESIDENCE(1HD) .SDF JOB TITLE: JAMES RESIDENCE 0 N 0 0 0 0 0 0 0 0 0 0 0 U) 10 (N 0 I U)U)w n 124 U) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/19/2016ROGRAM FILES\HRS SYSTEMS\JP CALCS\JAMES RESIDENCE(1HD) .SDF JOB TITLE: JAMES RESIDENCE NFPA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 0 PRESS. 0 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 86.5 70.0 500.0 86.4 26.0 49.9 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 - 0.0 SOURCE 49.9 26.0 2 0.0 - - - - 45.8 - - - 2A 0.0 - - - - 42.8 - - - D 0.0 - - - - 42.4 - - - C 0.0 - - - - 36.9 - - - 2B 0.0 HOSE STREAM 35.7 5.0 2C 0.0 - - - - 35.5 - - - 3A 5.0 - - - - 32.8 - - - 3B 7.0 - - - - 30.6 - - - 3 9.0 - - - - 29.0 - - 4 11.0 - - - - 27.8 - - - 4A 11.0 - - - - 24.8 - - - 5 15.0 - - - - 21.6 - - - 6 15.0 - - - - 20.2 - - - 7 15.0 - - - - 19.0 - - - 101 15.0 - - - - 20.2 - - - 102 15.0 - - - - 20.2 - - - 103 15.0 K= 4.90 18.4 21.0 9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/19/2016ROGRAM FILES\HRS SYSTEMS\JP CALCS\JAMES RESIDENCE(1HD) .SDF JOB TITLE: JAMES RESIDENCE NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pè) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 Source 0.0 16.00 150 4.2 1 0.0 49.9 26.0 2A 1(1.000 T: 6.0 7.00 0.0 2 0.0 45.8 26.0 0.995 G: 1.0 23.00 0.181 4.2 Pipe: 2 0.0 Fixed Pressure Loss Device 2 0.0 45.8 26.0 D 3.0 psi, 26.0 gpm 2A 0.0 42.8 26.0 Pipe: 3 0.0 0.0 2.00 150 0.3 2A 0.0 42.8 26.0 C L1.000 ---- 0.00 0.0 D 0.0 42.4 26.0 1.025 2.00 0.157 0.3 Pipe: 4 0.0 Fixed Pressure Loss Device D 0.0 42.4 26.0 2B 5.5 psi, 26.0 gpm C 0.0 36.9 26.0 Pipe: 5 H.S. 5.0 Disch 1.00 150 1.3 C 0.0 36.9 21.0 2C L1.000 T: 7.0 7.00 0.0 26 0.0 35.7 26.0 1.025 8.00 0.157 1.3 Pipe: 6 0.0 0.0 2.00 150 0.2 2B 0.0 35.7 21.0 3A L1.000 ---- 0.00 0.0 2C 0.0 35.5 21.0 1.025 2.00 0.105 0.2 Pipe: 7 0.0 0.0 40.00 150 2.6 2C 0.0 35.5 21.0 3B E1.500 ---- 0.00 -2.2 3A 5.0 32.8 21.0 1.610 40.00 0.012 0.5 Pipe: 8 0.0 0.0 3.00 150 2.2 3A 5.0 32.8 21.0 3 L1.000 E: 3.0 10.00 -0.9 36 7.0 30.6 21.0 1.025 T: 7.0 13.00 0.105 1.4 Pipe: 9 0.0 0.0 3.00 150 1.6 3B 7.0 30.6 21.0 4 F1.000 Er 7.0 7.00 -0.9 3 9.0 29.0 21.0 1.101 10.00 0.074 0.7 Pipe: 10 0.0 0.0 2.00 120 1.2 3 9.0 29.0 21.0 4A A1.000 ---- 0.00 -0.9 4 11.0 27.8 21.0 1.049 2.00 0.142 0.3 Pipe: 11 0.0 Fixed Pressure Loss Device 4 11.0 27.8 21.0 5 3.0 psi, 21.0 gpm 4A 11.0 24.8 21.0 Pipe: 12 0.0 11.2 7 8.00 150 3.2 4A 11.0 24.8 9.8 6 F1.000 E: 7.0 12.00 -1.7 5 15.0 21.6 21.0 1.101 B: 5.0 20.00 0.074 1.5 NotE SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/19/2016R0GRAM FILES\HRS SYSTEMS\JP CALCS\JAMES RESIDENCE(1HD).SDF JOB TITLE: JAMES RESIDENCE Pipe Tag K-fac Add Fl Add Fl To Fit: L C Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf/ft. Pipe: 13 0.0 0.0 65.00 150 5 15.0 21.6 9.8 7 F1.000 23:10.0 10.00 6 15.0 20.2 9.8 1.101 75.00 0.018 Pipe: 14 0.0 0.0 12.00 150 101 15.0 20.2 0.0 F1.000 E: 7.0 7.00 6 15.0 20.2 0.0 1.101 19.00 0.000 Pipe: 15 0.0 0.0 1.00 150 102 15.0 20.2 0.0 F1.000 E: 7.0 7.00 6 15.0 20.2 0.0 1.101 8.00 0.000 Pipe: 16 0.0 21.0 103 48.00 150 6 15.0 20.2 -11.2 103 F1.000 2L: 2.0 22.00 7 15.0 19.0 9.8 1.101 4B:20.0 70.00 0.018 Pipe: 17 4.90 21.0 Disch 1.00 150 7 15.0 19.0 0.0 F1.000 E: 7.0 7.00 103 15.0 18.4 21.0 1.101 8.00 0.074 Pipe: 18 0.0 21.0 103 72.00 150 5 15.0 21.6 -9.8 6 F1.000 4E:28.0 43.00 7 15.0 19.0 11.2 1.101 3B:15.0 115.00 0.023 NOTES (HASS) Calculations were performed by the HASS 8.5 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.029 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (Pt) (Pe) Not (Pf) 1.4 0.0 1.4 0.0 0.0 0.0 0.0 0.0 0.0 1.3 0.0 1.3 2.7 0.0 2.7 INNOVATIVE FIRE PROTECTION, INC. 8779 COTTONWOOD AVENUE SUITE 101 SANTEE,CA 92071 HYDRAULIC CALCULATIONS FOR JAMES RESIDENCE 4020 JAMES DRIVE CARLSBAD, CA 92008 FILE NUMBER: C6210 DATE: MAY 19, 2016 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL/LIGHT DENSITY: .05 gpm/sq. ft. AREA OF APPLICATION: 376 sq. ft. COVERAGE PER SPRINKLER: 16'X16'-256 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 26.3 gpm TOTAL WATER REQUIRED (including hose): 31.3 gpm FLOW AND PRESSURE (@ BOR) : 26.3 gpm @ 21.9 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: INNOVATIVE FIRE PROTECTION, INC. DESIGN/LAYOUT BY: JOE PLASSMEYER AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 711148 CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 16080621 HRS SYSTEMS, INC. 0 CO 0 0 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 5/19/2016ROGRAM FILES\HRS SYSTEMS\JP CALCS\JAMES RESIDENCE(2HD) .SDF JOB TITLE: JAMES RESIDENCE 0 0 0 0 0 0 0 0 0 0 0 0 00 ('4 0 0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 5/19/2016ROGRAM FILES\I-IRS SYSTEMS\JP CALCS\JAMES RESIDENCE(2HD) .SDF JOB TITLE: JAMES RESIDENCE NFPA MATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 86.5 70.0 500.0 86.4 31.3 47.1 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 31.3 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 26.3 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE NOTES (FT) (PSI) (GPM) 1 0.0 SOURCE 47.1 31.3 2 0.0 - - - - 41.3 - - - 2A 0.0 - - - - 38.3 - - D 0.0 - - - - 37.8 - - - C 0.0 - - - - 31.8 - - - 2B 0.0 HOSE STREAM 30.0 5.0 2C 0.0 - - - - 29.7 - - - 3A 5.0 - - - - 26.8 - - - 3B 7.0 - - - - 23.9 - - - 3 9.0 - - - - 21.9 - - - 4 11.0 - - - - 20.6 - - - 4A 11.0 - - - - 15.1 - - - 5 15.0 - - - - 11.1 - - - 6 15.0 - - - - 7.6 - - - 7 15.0 - - - - 8.9 - - - 101 15.0 K= 4.90 7.0 13.0 102 15.0 K= 4.90 7.4 13.3 103 15.0 - - - - 8.9 - - - 'SPRINKLER SYSTEM HYDRAULIC ANALYSIS . Page 4 DATE: 5!19/2016R0GRAM FILES\HRS SYSTEMS\JP CALCS\JAMES RESIDENCE(2HD) .SDF JOB TITLE: JAMES RESIDENCE NFPA PIPE DATA Pipe Tag K-fac -Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) NotE To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pfi'ft. (Pf) Pipe: 1 Source 0.0 16.00 150 5.9 1 - 0.0 47.1 31.3 2A K1.000 T: 6.0 7.00 0.0 2 0.0 41.3 31.3 0.995 G: 1.0 23.00 0.255 5.9 Pipe: 2 0.0 Fixed Pressure Loss Device 2 0.0 41.3 31.3 D 3.0 psi, 31.3 gpm 2A 0.0 38.3 31.3 Pipe: 3 0.0 0.0 2.00 150 0.4 2A 0.0 38.3 31.3 C - L1.000 ---- 0.00 0.0 D 0.0 37.8 31.3 1.025 2.00 0.221 0.4 Pipe: 4 0.0 Fixed Pressure Loss Device 0 0.0 37.8 31.3 23 6.0 psi, 31.3 gpm C 0.0 31.8 31.3 Pipe: 5 H.S. 5.0 Disch 1.00 150 1.8 C 0.0 31.8 26.3 2C L1.000 T: 7.0 7.00 0.0 2B 0.0 30.0 31.3 1.025 8.00 0.221 1.8 Pipe: 6 0.0 0.0 2.00 150 0.3 2B 0.0 30.0 26.3 3A L1.000 ---- 0.00 0.0 2C - 0.0 29.7 - 26.3 1.025 2.00 0.160 0.3 Pipe: 7 0.0 0.0 40.00 150 2.9 2C 0.0 29.7 26.3 33 E1.500 ---- 0.00 -2.2 3A 5.0 26.8 26.3 1.610 40.00 0.018 0.7 Pipe: 8 0.0 0.0 3.00 150 - 2.9 3A 5.0 26.8 26.3 3 L1.000 E: 3.0 10.00 -0.9 3B 7.0 23.9 - 26.3 1.025 T: 7.0 13.00 0.160 2.1 Pipe: 9 0.0 0.0 3.00 150 2.0 33 7.0 23.9 26.3 4 F1.000 E: 7.0 7.00 -0.9 3 9.0 21.9 26.3 1.101 10.00 0.113 1.1 Pipe: 10 0.0 0.0 2.00 120 1.3 3 9.0 21.9 26.3 4A A1.000 ---- 0.00 -0.9 4 11.0 20.6 26.3 - 1.049 2.00 0.216 0.4 - Pipe: 11 0.0 Fixed Pressure Loss Device 4 11.0 20.6 26.3 5 5.5 psi, 26.3 gpm 4A 11.0 15.1 26.3 Pipe: 12 0.0 10.0 7 8.00 150 4.0 4A 11.0 15.1 16.3 6 F1.000 E: 7.0 12.00 -1.7 5 15.0 11.1 26.3 1.101 B: 5.0 20.00 0.113 2.3 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 5/19/2016ROGRAM FILES\HRS SYSTEMS\JP CALCS\JAMES RESIDENCE(2HD) .SDF JOB TITLE: JAMES RESIDENCE Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node! Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot. (Q) Disch Act ID (ft.) T Pf!ft. (Pf) Pipe: 13 0.0 13.3 102 65.00 150 3.5 5 15.0 11.1 13..0 101 F1.000 2B:10.0 10.00 .0.0 6 15.0 7.6 16.3 1.101 75.00 0.047 3.5 Pipe: 14 . 4.90 13.0 Disch 12.00 150 0.6 6 .15.0 7.6 0.0 F1.000 E: 7.0 7.00 0.0 101 15.0 7.0 13.0 1.101 19.00 0.031 0.6 Pipe: 15 4.90 13.3 Disch 1.00 150 0.3 6 15.0 7.6 0.0 F1.000 E: 7.0 7.00 0.0 102 15.0 7.4 13.3 . 1.101 8.00 0.032 0.3 Pipe: 16 0.0 13.3 102 48.00 150 1.3 7 15.0 . 8.9 13.0 101 F1.000 2L: 2.0 22.00 0.0 6 15.0 7.6 10.0 . 1.101 43:20.0 70.00 0.019 1.3 Pipe: 17 0.0 0.0 1.00 150 0.0 103 15.0 8.9 0.0 F1.000 E: 7.0 7.00 0.0 7 15.0 8.9 0.0 1.101 8.00 0.000 0.0 Pipe: 18 0.0 0.0 72.00 150 2.2 5 15.0 11.1 10.0 6 F1.000 4E:28.0 43.00 0.0 7 15.0 8.9 10.0 1.101 3B:15.0 115.00 0.019 2.2 NOTES (HASS) : Calculations were performed by the HASS 8.5 computer program under license no. 16080621 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.062 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 12.9 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Not Recordall® Disc Meters Badger Meter Lead-Free Bronze Alloy, Sizes 5I8 5/8t1 x 3/4', 3/411 & 1" NSF/ANSI Standards 61 and 372 Certified .*.. .•,.,L. I....4 '--". 4, c f - - Model LP-5/8", 5/8" x 3/4" Model 25-5/8,5/8" x 3/4" Model 35-3/4" - Model 55-1" Model 70-1' DESCRIPTION The Recordall Disc Series meters meet or exceed the most recent revision of AWWA Standard C700 and are available in a lead-free bronze alloy. The meters comply with the lead-free provisions of the Safe Drinking Water Act, are certified to NSF/ANSI Standards 61 and 372 (Trade Designations: MLP-LL M25-LL, M35-LL, M55-LL, M70-LL) and carry the NSF-61 mark on the housing All components of the lead-free bronze alloy meter (housing, measuring element, seals, and soon) comprise the certified system. Applications: For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. Operation: Water flows through the meter's strainer and into the measuring chamber where it causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanently sealed register. The follower magnet is connected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register or encoder face. Operating Performance: The Recordall Disc Series meters meet or exceed registration accuracy for the low flow rates (95%), normal operating flow rates (100 ± 1.5%), and maximum continuous operation flow rates as specifically stated in AWWA Standard C700. Construction: Recordall Disc meter construction, which complies with ANSI/AWWA standard C700, consists of three basic components: meter housing, measuring chamber and permanently sealed register or encoder. The meter is available in a lead-free bronze alloy with externally-threaded spuds. A corrosion-resistant engineered polymer material is used for the measuring chamber. Magnetic Drive: Direct magnetic drive, through the use of high-strength magnets, provides positive, reliable and dependable register coupling for straight-reading or AMR/AMI meter reading options. Tamper-Proof Features: Unauthorized removal of the register or encoder is inhibited by the option of a tamper detection seal wire screw, TORX° tamper-resistant seal screw or the proprietary tamper-resistant keyed seal screw. Each can be installed at the meter site or at the factory. RDM-DS-00464-EN-03 AWWA (October 2015) Maintenance: Badger Meter Recordall Disc Series meters are designed and manufactured to provide long-term service with minimal maintenance. When maintenance is required, it can be performed easily either at the meter installation or at any other convenient location. To simplify maintenance, the register, measuring chamber, and strainer can be replaced without removing the meter housing from the installation. No change gears are required for accuracy calibration. Interchangeability of parts among like-sized meters and meter models also minimizes spare parts inventory investment. The built-in strainer has an effective straining area of twice the inlet size. Connections: Tailpieces/Unions for installations of meters on various pipe types and sizes, including misaligned pipes, are available as an option. Meter Spud and Connection Sizes Model L!, Size x Laying Designation Length ,,B ,, Bore Dia. Coupling Nut and Spud Thread Tailpiece Pipe Thread (NPT) LP 5/8" x 7-1/2" 5/8" 3/4 (5/8") 1/2" 5/8'x3/4" x 7-1/2" 5/8'3I4" 1(3/4") 3/4" 25 5/8" x 7-1/2" 5/8" 3/4 (5/8") 1/2" 5/8" x3/4" x 7-1/2" 5/8' 3/4" 1" (3/4") 3/4" 3/4" x 7-1/2" 3/4" 1(3/4") 3/4" 35 3/4" x 9" 3/4" 1" (3/4") 3/4" 3/4"xl" x 9" 3/4" 1-1/4(1") 1" 55 V. x 10-3/4" 1" 1-1/4(1") 1" 70 V. x 10-3/4" 1" 1-1/4(1") V. I AS1 rool 22 4020 JAMES DR Product Data Sheet Recordall® Disc Meters, Lead-Free Bronze Alloy, Sizes 518','518"x314'1'314"& 1" SPECIFICATIONS Model LP Model 25 Model 35 Model 55 Model 70 (5/8' & 5/8" x 3/4") (5/8" & 5/8" x 3/4") (3/4") (111) (111) Typical Operating 0.5 ... 20gpm 0.5 ... 25gpm 0.75 ... 35gpm 1 ... 55gpm 1.25...70 gpm Range (0.11.. .4.5 m3/hr) (0.11.. .5.7 M3 /hr) (0.17.. .7.9 M3 /hr) (0.23.. 12.5 m3/hr) (0.28... 16 m3/hr) (100%± 1.5%) 0.25 gpm 0.25 gpm 0.375 gpm 0.5 gpm 0.75 gpm Low Flow (0.057 m3/hr) (0.057 M3 /hr) (0.085 m3/hr) (0.11 m3/hr) (0.17 m3/hr) Mm. 95% Mm. 98.5% Mm. 97% Mm. 95% Mm. 95% Maximum Continuous logpm 15 gpm 25 gpm 40 gpm 50gpm (2.3 m3/hr) (3.4 ml/hr) Operation (5.7 m3/hr) (9.1 M3 /hr) (11.3 M3 /hr) 5/8" size: 5/8" size: Pressure Loss 2 psi @ 10 gpm 3.5 psi @ 15 gpm at Maximum (0.14 bar @2.3 m3/hr) (0.24 bar @3.4 m3/hr) 5 psi @25 gpm 3.4 psi @40 gpm 6.5 psi @50 gpm Continuous 5/8" x 3/4" size: 5/8" x 3/4" size: (0.37 bar @5.7 m3/hr) (0.23 bar @9.1 ml/hr) (0.45 bar @ 11.3 M3 /hr) Operation 1.5 psi @ 10 gpm 2.8 psi @ 15 gpm (0.10 bar @2.3 m3/hr) (0.19 bar @3.4 m3/hr) Maximum Operating 80° F (26° C) Temperature Maximum Operating 150 psi (10 bar) Pressure Measuring Nutating disc, positive displacement Element Available in NL bronze and engineered polymer to fit spud thread bore diameter sizes: Meter 5/8" size: I Connections 5/8' or I 5/8" ON 15 mm) I 3/4" ON 20 mm) I 1' ON 25 mm) I 1" ON 25 mm) 3/4" (DN 15 mm) 5/8" x 3/4" size: I 3/4" ON 15 mm) MATERIALS Model LP (5/8"&5/8"x3/4") Model 25 (5/8"&5/8"x3/4") Model 35 (3/4") Model 55 (1") Model 70 (1") Meter Housing Lead-free bronze alloy Housing Bottom Plates Lead-tree bronze alloy, cast iron, engineered polymer Cast iron, lead-free bronze alloy Measuring Chamber Engineered polymer Disc Engineered polymer Trim Stainless steel Strainer Engineered polymer Disc Spindle Engineered polymer Stainless steel Stainless steel Engineered polymer Stainless steel Magnet Ceramic Ceramic Ceramic Polymer bonded Ceramic Magnet Spindle Engineered polymer Stainless steel Stainless steel Engineered polymer Stainless steel Register Lid and Shroud I Engineered polymer, bronze Page 2 RDM-DS-00464-EN-03 AWWA October2015 25 Reco,dalf - _7 Gallons 3. II'OI Oo: 25 •iA Recosdall" - feol§ ...7 Cubic Feet .3.: ........ 0,09 °'2' _.. ~_o ;_0,07 m3 0,03_ oi_o,_oioj 0,06 0,04 o.s Product Data Sheet DIMENSIONS Meter Size Model A Laying Length B Height Reg. C Centerline Base Width Approx. Shipping Weight 5/8"and 5/8"x 3/4"(15 mm) LP 7-1/2 (190 mm) 3.70 (94 mm) 1.26(32mm) 3.75" (95 mm) 3 lb (1.4 kg) 5/8" (15 mm) 2 7-1/2 (190 mm) 4-15/16" (125mm) 1-11/16" (42 mm) 4-1/4" (108 mm) 4-1/2 lb (2 kg) 5/8" x 3/4" (15 mm) 7-1/2" (190 mm) 4-15/16" (125 mm) 1-11/16" (42 mm) 4-1/4" (108 mm) 4-1/2 lb (2 kg) 3/4" (20 mm) 35 7-1/2(190 mm) 5-1/4" (133 mm) 1-5/8(41 mm) 5" (127 mm) 5-1/2 1b(2.5 kg) 3/4" (20 mm) 9(229mm) 5-1/4(133 mm) 1-5/8" (41 mm) 5" (127 mm) 5-3/4 lb (2.6 kg) 3/4" xl" (20 mm) 9(229mm) 5-1/4" (133 mm) 1-5/8" (41 mm) 5" (127 mm) 6 lb (2.7 kg) 1(25mm) 55 10-3/4" (273 mm) 6" 052 mm) 2-1/32" (52 mm) 6-1/4" (159 mm) 8-3/4 lb (3.9 kg) 1" (25 mm) 701 10-3/4" (273 mm) 6-1/2 (165 mm) 2-5/16(59mm) 1 7-3/4" (197 mm) 1 11-1/2 lb (5.2 kg) REGISTERS I ENCODERS Standard—Sweep-Hand Registration The standard register is a straight-reading, permanently sealed magnetic drive register. Dirt, moisture, tampering and lens fogging problems are eliminated. The register has a six-odometer wheel totalization display, 360" test circle with center sweep hand, and flow finder to detect leaks. Register gearing is made of self-lubricating engineered polymer, which minimizes friction and provides long life. The multi-position register simplifies meter installation and reading. The register capacity is 10,000,000 gallons (1,000,000 ft', 100,000 m3). A Model 25 register is used in the following example: Model Gallon Cubic Feet Cubic Meter LP 10 1 0.1 25(5/8") 10 1 0.1/0.01 25(5/8" x 3/4") 10 1 0.1/0.01 35 10 1 0.1 55 10 1 0.1 70 10 1 0.1 Optional—Encoders for AMR/AMI Reading Solutions AMR/AMI solutions are available for all Recordall Disc Series meters. All reading options can be removed from the meter without disrupting water service. Badger Meter encoders provide years of reliable, accurate readings for a variety of applications and are also available pre-wired to Badger Meter approved AMR/AMI solutions. See details at www.badgermeter.com. October 2015 RDM-DS-00464-EN-03 AWWA Page 3 Recordalle Disc Meters, Lead-Free Bronze Alloy, Sizes 5/8','518"x314','314"& 1" PRESSURE LOSS CHARTS Rate of Flow in Gallons per Minute Model LP 518 Model LP 5/8' x 3/4' 1 10 100 25 20 15 10 a) 0 5 0 Model 25 5/8" 1 10 100 in ,n san 25 20 15 0 10 a) 0- 5 0 Ii Page 4 RDM-DS-00464-EN-03 AWWA October2015 Product Data Sheet PRESSURE LOSS CHARTS (CONTINUED) Rate of Flow in Gallons per Minute Model 25 5/8 x 3/4" Ii4s:IsI - ______. — __ NOW __ - — _____.. - NO - — ___. - _____u — _ ______. - ____u _ NO MEMO — ------u r • Model 353/4" 1 1 0 100 2 4 6 6 7fl 40 6(1 Rn 25 20 to 0 15 vi 10 toO. 01 a 0 5 0 Model 55 1" 1 - 10 100 — _____fl — ______. - . — ______. - ______. I - ______. • — ______. -WE __. — ______. - ______. _. • _. October2015 RDM-DS-00464-EN-03AWWA Pages Recordalle Disc Meters, Lead-Free Bronze Alloy, Sizes 518','518"x314"' 314"& 1" PRESSURE LOSS CHARTS (CONTINUED) Rate of Flow in Gallons per Minute Model 701" 1 10 100 — -____. —mom Mm 20 - — —No — _____. - — ____. -ME __ Ui MEME __ ___ _. £WAMME 10 — -___. — ______. — ----n- — — -____. - — -____. — — - EEEWAmm"Emmi —WMENIM MMMMW $ - --------=-- ____ =MM ME — __. ACCURACY CHARTS Model IF 5/8 .1 10 in inn Model LP 5/8' x 3/4" 1.0 10 100 Page 6 RDM-DS-00464-EN-03 AWWA October2015 Product Data Sheet ACCURACY CHARTS (CONTINUED) Model 25 5/8 1.0 -. 10 100 Model 25 5/8' x 3/4" 1 1.0 10 100 Model 35 3/4" .1 1.0 10 100 October2015 RDM-DS-00464-EN-03 AWWA Page 7 ..,.,-,,- _.-•w—_•4- '.- - -_-.,,w. —-:---- ..—,--- - -. ,-,-.----- - Recordall Disc Meters, Lead-Free Bronze Alloy, Sizes S/8 5/8"x 3/4' 314"& 1" ACCURACY CHARTS (CONTINUED) Model 551" 1 1.0 10 100 Model 70 1" 1 1.0 10 -.100 Making Water VisibIe MAKING WATEhSIBLEnd PEC(MDALL ate rcqlatsied traderritiks ofOadyor Meter, Inc. Otheror Jernarkcappearing in thipdoc un/cot ara t1w.. property oc their recpecticc entities [UQ Or, c-jiltinuaus ,esuarch, rit -,dut. nriPruven act; sitd ci hcnce.rncnta. 0edqer Meter rcrar664 tha rkjht t'u chatii.iu product or pvstern cptciftciitionc without n011c4. except to iho r°ct-'ilt an out.srandiny contractual chtiqaticn cdtt. 0 2.015 Baiqet Meict, Inc. All tlqhtp reserved. www.badgerrneter.com The Americas I Badger Mete; l 445 rawi In....eLi..7 04 I PU Ens 346036 001w,,ukcc WI 5322';-8536 I ,/08-37E-4337 i 411-355-0400 Mexico I Cadger Mater de 1.3s Americas, S.A. cIa C.V. I PedrO Luc 0ew3,, N32 I Esq. Angelina N'24 1 Colonia G,,aduiuisc he (PU lu50 t MO/co. 06 I MOUo Europe, Middle East and Africa I Badger Meter Eu,opaGrnbH I No, ilnon Stf 7(-1 720/' 14,',tO,its I Otmany Europe. Middle East Branch Office I 8a48eMcterhi,r'1re I 10 31442 1 01,031 Sikca Own. Hcad Quailcr tId13. Wi'q ', 4)ffkc 1003 1 Oihe:!iOt'L 1 971 4-371 POliO Coach Rep ablici badgerMeter Czech Republic cr0, I M.,l4uu, 2062/26 I6A 114 Erie, C7.e1 Ee1,ubl,c I 6421-5-4426411 Slovakia I Badger Meter Slovakia cr0. I Ernest,,, )OWIP t 831 0_1 0, ti,iac, 51waki 1 +421-2-6463 8331 ASia Padlic 6ad9er Meter I 80 MerOIc 11a'eslc PcI! 21-110 PirLwav Pa,a/c' I 0e9.3pow 4492')Oj 165-r3346426 China I Sadger Mote, I7. 282 '4 h3ee21,c.',o ilih./r,I1anq 12,ct,,:i Shun ha Oh/rn PUt tot a 56-21-9763 tat) Loqacy Document ilunihrs IIDM-OS-0t6162, 63.14,45. ce., an-I 73 ZURN Model 950XL WILKINS Double Check Valve Assembly Application Designed for installation on water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. Standards Compliance (All sizes approved horizontal. Vertical approvals as listed below.) ASSE® Listed 1015 (vertical 3/4", 1 1/4", 1 1/2" & 2") IAPMO® Listed (vertical 1 1/4-2") CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern Cali- fornia (vertical 3/4") City of Los Angeles Approved (vertical 1-1/4-2") NYC MEA 426-89-M VOL 3 Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM, NSF Listed Springs Stainless steel, 300 series Features Sizes: 3/4", 1", 11/2", 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI 131 .20.1 Options (Suffixes can be combined) LI - with full port QT ball valves (standard) L - less ball valves fl U - with union ball valves S - with bronze "Y" type strainer TCU - with test cocks "vertical" up V - with union swivel elbows (3/4" & 1") fl OSY - with OS & Y gate valves FDC - with fire hydrant connection (2" only) FT - with integral male 45° flare SAE test fitting L PF - with Z-BiteTM push fit connections* (1/2-1 "only) PR - with ZPressTM press fit connections* *Fittings ship in box with valve and must be threaded into valve by hand on site. Accessories fl Repair kit (rubber only) fl Thermal expansion tank (Model XI) LI QT-SET Quick Test Fitting Set D'LLBJ Dimensions & Weights (do not include pkg.) DIME NSIONS_(a proximate) WEIGHT MODEL A UNION LESS WITH SIZE A BALL B LESS BALL C D E F G BALL BALL VALVES VALVES VALVES VALVES mm in. mm in. Imm in. Immmm in. mm in. I mm in. I mm in. lbsl kg I kg 3/4 20 111/4 286 121/2 318 7 178 1 1/2 38 3 76 31/2 89 3 76 15 381 5 1 2.3 7 3.2 1 25 1121/4 311 137/8 353 7 178 1 1/2 38 3 76 3 1/2 89 3 76 173/4 451 8 3.6 12 5.4 11/4* 32 151/2 419 181/2 470 109/16 268 2 51 31/2 89 41/2 114 41/2 114 211/2 546 16 7.3 22 10 11/2 40 171/8 435 191/8 486 109/16 268 2 1 51 31/2 89 41/2 114 41/2 114 223/4 578 16 7.3 22 10 2 50 181/4 460 20 508 109/16 268 2 51 131/2, 89 41/2 114 141/2 114 251/8 638 16 7.3 28 12.7 *Size 1-1/4" Discontinued Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Rev. D Date: 4/15 Document No. BF-950xL Product No. Model 950XL www.zurn.com I Page l of 2 3.2 6.3 9.5 12.6 15.8 [iii 1!i 103 - Flow Characteristics 0 Rated Flow (established by approval agencies) MODEL 950XL 3/4", 1", 1 1/4", 1 1/2" & 2" (STANDARD & METRIC) FLOW RATES (us) 1.26 2.52 3.8 5.0 15 15 (20mm) 0 10 10 _ _ _ uj 5 5 U, Ui 0 0 20 40 60 80 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec lOft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 1 63 95 52 78 1 105 167 DIRECTION OF FLOW OUTDOOR INSTALLATION INDOOR INSTALLATION Specifications The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM 8 584), the seat rings and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance with- out removing the device from the line. The Double Check Valve Backflow Preventer shall be a ZURN WILKINS Model 950XL. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Page 2 of 2 Item Description 1 Manifold Body, Male Thread x Male Thread 2 Inline Check Valve, Spring Loaded 3 Flow Switch with Retard 4 Drain Valve, with optional pressure relief valve 5 Pressure Gauge, 0-300 psi National Fire Products, LLC RESI-RISERTM The RESI-R1SER1M is a pre-assembled, compact, attractive fire sprinkler riser unit for residential sprinkler systems in accordance with NFPA 13, 13R and 13D. The RESI-RISERTM manifold is manufactured as a one- piece casting that is air-tested for leaks. Raised lettering on both sides allows the RESI-RISERTM to be installed to the right or left and easily identifies the flow direction and Test and Drain outlet. Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring. The flow switch has dual SPDT switches and a retard of 0-90 seconds. An optional "all in one" cost saving combination Pressure Relief Valve/Test and Drain Valve is available. The RESI-RISERTM unique design gives the ability to be installed within standard 2 x 4 frame construction. Every size RESI-RISERTM fits within a 2 x 4 wall framed at 16 inches on center. Technical Data Sizes: 1", 1Y", 11/z', and 2" Style: Thread x Thread Listing: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi Pressure Relief Valve/Test and Drain US Patent 1* 6,076,545 RESl-RISERTM Size Chart Description 1" 11/4" 1>'2" 2" H eight* 13" 13" 13" 13" Width** 10-3/4" 11-1/2" 12" 12-1/2" Depth 3-1/2" 3-1/2" 3-1/2" 3-1/2" Drain Size 1/2" 1" 1" 1" Dimensions include all spacing needed to operate drain valve and remove flow switch cover * Without check valve ** With or without pressure relief valve © National Fire Products, LLC (800) 5287978 Pressure Loss Tables Pressure Loss in 1" Resi-Riser Pressure Relief/Test and Drain How it Works L Normal Position - Static Pressure 0 10 15 20 25 30 35 40 Flow (gpm) Pressure Loss in 1-1/4" Resi-Riser Relieving Pressure Exceeding 175 psi Lj ': IA i1"i'' ,IiIIII1I 0 10 15 20 25 30 35 40 45 50 55 60 Flow (gpm) Pressure Loss in 1-1/2" Resi-Riser Manual Open - Drain C r Flow Switch Test U • a 8 6 C) 2 -----v--- n L1i11 1JP 'I --------------------I I I I I I I 0 10 15 20 25 30 35 4045 50 55 60 65 70 75 80 Flow (gpm) Pressure Loss in 2" Resi-Riser Locked Closed for Hydrostatic Test 11TI[I1I 3 CL . ITJ I fA - H1L1J1ITLI1 0 15 25 35 45 55 65 75 85 95 Flow (gpm) © National Fire Products, LIC (800) 528-7978 Page 1 of & SENJU SPRINKLER CO.,LTD.0 . Residential Lead Free Flat Concealed Sprinkler Pendent, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on arid/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. Th Mode! ..R::S is to he used in we pipe residential sprinlder ystems.f.or P_ne and Manufactured Homes per NJFPA13D; wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/ha11'2) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWAIAs Water Utility Council, and California Assembly Bill #1953 as having les than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and J/1 of any other authorities havinqjurisdictiorz. hi the event of this condition, consult the authorities having juriSdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. U085160 Date Feb/09/2015 Page 2 of 8 II TECHNICAL DATA Approvals: UL05 Listed, NSF-61 -G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1 bar) Discharge Coefficierit (Nominal K-Factor): K4.9 GPM/psi°'° (70.6 LPM/b3r12) Temperature Rating: 1621 (72°C) Sprinkler with 140'F (60°C) Cover Plate 175°F (79°C) Sprinkler with 162°F (72°C) Cover Pav Color Code (Sprinkler) 162°F (72°C): Uncolored 1751 (790C): White Color Code (Cover Plate) 1401 (60°C): No Mark 1621 (72°C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, ivory, Seige,B10wn,o1ack, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senu Sprinkler representative with any custom orders. Please see chart an Page 8 for more detail. Physical Characteristics: Ref. Figure 1 OPERATION 2- i 6' (b 52mm) Markin Lot No. Year of Manufacture El -SIN 5S6464 -K-factor: (4.9 Temperature Rating: 162r/72c E UL Mark or I 75F/79c - Control No. : 6P37 -NSF Murk: tdSF-61-13 RES SPKR Body (Copper Alloy) (D Deflector (Phosphorus Bronze) CD Cookef (FIFE) - - ® Fusible Metal (Solder) a) Hoot Collector (Copper) 0 cover Pinto Assembly r 3-t" (83mrn) or 2- 4"square (068mm) FIGURE 1. Model RC-RES K4.9 Col., Cod SIN s58464 K—factor: K4.9 Tenaperalure Rating I62F/72c or iSP/inc UL Mork COVER PLATE SPRINKLER (lop view) (Bottom view) FIGURE 1-1. Marking (Color Cod?J In case of fire, the solder component that holds toge;ier the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops dov to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal ccmponents of the sprinkler to fall apart. This leads to allow the water now to be distributed on the affected by fire area. (Ref. FigL1T6 2) Normal Condition Cover Plate 0per3:ion =# Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative purpose only) Document No. U085160 Date Feb/09/2015 DESIGN CRITERIA Page 3 of 8 The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. ...... .. .• T.spray.from-the sarir.kleris.distriAuteLi.radically.outward and downward from the spiinkler..defl.ector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray b partitions, room dividers; overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of design sprinklers as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. Document No. U085160 Date . Feb/09/2015 Page 4 of & A minimum discharge 0.1GPMlsq.ft. [4.07LPMIsq.m] over the design area' comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. TABLEA. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model SS8464 Maximum Ordinary Intermediate - Coverage Maximum Temperature Rating Temperature Rating Deflector Minimum Area(a)Spacing 162T (72°C) 175T (79°C) to Installation I Spacing Flow (b) Pressure (b)- Flow0'> I Pressure(D) Ft. Ft. Ft. Ceiling Type Ft. (m xm) (m) GPM PSI GPM PSI (m) (LPM) (bar) (LPM) (bar) Smooth 12x12 12 13 7.0 13 7.0 Ceilings (3.7x3.7) (3.7) (49.2) (0.48) (49.2) (0.48) 3/8 to 7/8 Inches. 14x14 14 13 7.0 13 7.0 Beamed (4.3x4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Ceilings per NFPA '-- ... ----3 ... ..7.0'--- .44 ..-- '---3.2 Conceed (4.9x4.9) (4.9) (49.2) (0.48) (53.0) (0.57) or 13 (2.4) Installed in beam 18x18 18 17 12.0 18 13.5 3/8 to (5.5x5.5) (5.5) (64.3) (0.83) (68.1) (0.93) 7/8 inches 20x20 20 21 18.4 - below (6.1x6.1) (6.1) (79.5) (1.27) - bottom of beam. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. (C) For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Document No. U085160 Date .Feb/09/2015 Page . 5 of 8 Use a torque of 7 to 14 ft.lbs (9.5 to 19.ONm) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Installing Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material insfthe .c r.pJint;o.theProt.ecti.va Cap-Before. the install itionaf4the-ceiliog, fhespr.iokferJostaftalioncan he started with.. the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the Tolerance Limit of Ceiling Level indicator on'the Protective Cap to check for proper installation height (Ref. Figure 3). Make a Space Here Do NOT Ave. Y' (6.4mm) Over-Tighten Groove on the Sprinkler ) Min. ,"(3,2mm) nre Limit of Ce lin Level Protective cop (Coi'ing Mounting Surface/ of the Socket Mouni:ing Sur ___ Wrench (45 Ceiling Hole Diameter Socket J CORRE] INCORRECT! . I FIGURE 3. INSTALLATION FIGURE 41 Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No. U085160 Date . Feb/09/2015 Step 3 Pull down FIGURE 5. PROTECTIVE CAP REMOVAL - b Ot e Cu LCJ co Mo Screw Deflector Cover Plate Assembly [ 2-W'(68mm) j or 3-jY4" (83mm) or 2- 5/a'square (068mm) FIGURE 6 INCORRECTj ICORRECT1 I INCORRCTI FIGURE 7. INSTALLATION (CORRECT OR INCORRECT) Document No. U085160 Date . Feb/09/2015 Page :7 of 8 RE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. VOTES - Wet pipe sprinkler systems must be maintained at a minimum temperature of 40 F/4 t to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. pip railoh for thaiiilénàne.öf the f1re protection system, permission to ôioiéth7ñài,Yorifröf valve rnListbé obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire nvoMng such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 100'F / 38°C Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No. U085 160 Date Feb/09/2015 Page : 8 of S ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC-RES (SIN: S58464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162"F (72°C) or 175'F (79°C) Cover Plate Assembly: 2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattern 2-5/8 Round, 140°F 0 0 - - 0 0 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 - - - - - - 0 0 2-5/8' Round, 162°F 0 - - - - - - 0 0 3-1,'4" Round, 1.62°F.,...0.....:..l_ . . . -..-., . . Tools for Installation of Model: RC-RES Socket for Model RC-RES Wrench & Socket for Model RC-RES Cap Remover RC Document No. U085160 Date : Feb/09/2015 2 Fl Res 30, 49, 58 & 76 Recessed Pendent / Fl Fl Res 30, 49, 58 & 76 Recessed Pendent / FP Fl Res 30, 49, 58 & 76 Fl Res 44 & 58 Fl Res 44 SWC CCP Pendent Recessed HSW/F2 Bulletin 135 Rev. M 1143 -ble CO Model Fl Residential Sprinklers for Design Density of .05 gpm1ft2 Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpmllt2 Types: F1 Res 30 Pendent Fl Res 30 Recessed Pendent/F2 Fl Res 30 Recessed Pendent/FP Fl Res 49 Pendent Fl Res 49 Recessed Pendent/Fl Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Recessed Pendent/Fl Fl Res 58 Recessed Pendent/FP Fl Res 76 Pendent Fl Res 76 Recessed Pendent/Fl Fl Res 76 Recessed Pendent/FP Fl Res 30 CCP Pendent Fl Res 49 CCP Pendent Fl Res 58 CCP Pendent Fl Res 76 CCP Pendent Fl Res 44HSW Fl Res 44 Recessed HSW/F2 Fl Res 58HSW Fl Res 58 HSWX KRes58 HSWX Fl Res 58 HSW Recessed HSW/F2 Fl Res 44 SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model Fl Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model Fl Res 44 SWC Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass-bulb and low profile decorative design. The Fl Res Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: 1/2" NPT (R½) K-Factor: 3.0 (43.2) (Actual) - Fl Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (83.5) (Actual) - Fl Res 58 Pendent & HSW Sprinkler 7.6 (109)(Actual) - Fl Res 76 Pendent Sprinkler 4.4(63) (Actual) - Fl Res 44 HSW Sprinkler Density: Minimum 0.05 gpm/ft2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 i-i escutcheon, /4 (19mm) adjustment 2 l/e HOLE 0/A. — (57.2=n] 1 I5/I6 o. I [49.2mm] I TURN COLLAR UNTIL - - -4 .- I X I/2 REDUCER TIGHT AGAINST SPRINKLER FACE OF FITTING TO WRENCH BOSS. DIM/8ENSION. [ CEILING 3/8 .-I I (Fl ESCUTCHEON) 3/8-7/8" (P2 ESCUTCHEON) ADJUSTMENT A A ':4... 3.2mm] I 2 27/32 014, I 2mm] mm,. I[72 Application Model Fl Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R, or 132013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are Escutcheon*, Fl or F2, Data: the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pen- dent sprinklers use only the Model D sprinkler Wrench; for installing Models Fl Res Recessed Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model Fl Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" mark- ing must face ceiling. Type Adjustment "A" Face of fitting to ceiling Deflector Distance below bottom of beam Inch (mm) Inch (mm) Inch (mm) Inch (mm) Fl 3/4 (19.0) Mm. Recessed = 1/a(41,3) /a(9.5) 1/4 (44.4) Max. Recessed =/e (22.2) V/a (28.6) 1(25.4) F2 1/2 (12.7) Mm. Recessed = 1/a (41.3) 3/a (9.5) 1/4 (44.4) Max. Recessed = V/a (28.6) /a (22.2) 11/4 (31.7) * Note: Escutcheons Fl or F2 may be used with Model Fl Res 49, 58 & 76 Recessed Pendent Sprinkler Model Fl Res 30 Recessed Pendent / F2 S iviooei i-i ties iu, 'es, ou & lb iena€ nt • Model Fl Res 49. 58 & 76 Recessed Pendent / Fl Fig. 1 Fig. 2 Technical Data: F1 Res 30 Pendent and Recessed Pendent (SIN R3511) Thread Size I Nominal Orifice Inch (mm) Max. Pressure psi (bar) I Sprinkler Temp. Rating I Max. Ambient Temp. I Actual K Factor I Sprinkler Length I Inch (mm) I °C °F /2"NPT (R V2) I 2;/" (8.2) 175 (12) I 155 I 175 68 79 I 100 38 3.0 (43.2) 2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (1550 80c) Intermediate Temp. Rating (1750F1790C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (Llmin) Pressure PSI (bar) Flow GPM (11mm) Pressure PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0 (0,48) 8(30,3) 7.0(0,48) Smooth ceilings 11/4 104(31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4.3) 10(37,8) 11(0,76) 10(37,8) 11(0,76) Beamed Ceilings per NFPA 13D, 13R (31.71044.4) using F2 escutcheon 8(2,4) X 16(4,9 X 4.9) 16(4,9) 13(49) 18.8(1,3) 0113 installed in beams 11/4 to 13/416 13(49) 18.8 (1,3) For Ceiling types refer to NFPA 13, 13R or 13D 2. Technical Data: Fl Res 49 Pendent and Recessed Pendent (SIN R3516) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size I Inch (mm) Pressure Temp. Rating Ambient Temp., K Length °C OF °C psi (bar) Factor Inch (mm) ½" NPT L (R 1/2) I h6" (11) 175 (12) I 155 175 68 79 100 150 I 38 66 I 4.9 (70.6) 2.25 (57) Ordinary Temp. Rating I Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (1550Fi8°C) (1750F1790C) Ft x Ft (m x m) Ft (m) to Ceiling Spacing Flow Pressure Flow Pressure GPM (Limin) PSI (bar) GPM (1/mm) PSI (bar) Inch (mm) Ft (m) 12 x 12(3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) Smooth Ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 13(49) 7,0 (0,48) 13 (49) 7.0(0,48) 1 t 4(25.4 to 102) using Fl escutcheon. 16 x 16 (4,9 x 4,9) 16(4,9) 13(49) 7.0 (0,48) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 130, 131R or 13 installed in 8 (2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17(64,3) 12(0,83) 17(64,3) 12(0,83) beams 11/4 to 1/4 (31.7 to 14.4) using F2 escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20 (75,7) 16.7 (1,14) 20 (75,7) 167(1,14) to 1/4 (25.4 t044.4) using Fl ___________________ ______________ escutcheon For Ceiling types refer to NFPA 13, 13R or 130 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector MinimumI Max. Coverage area Max. Spacing (155°F/68°C) (1750F/790C) Ft x Ft (mx m) Ft (m) to Ceiling Spacing Flow Pressure Flow Pressure GPM( Llmin) PSI (bar) GPM (1/mm) PSI (bar) Inch (mm) Ft (m) 12 x 12(3,6 x 3,6) 12(3,6) 15(57) 9.4(0,65) 15(57) 9.4(0,65) Smooth Ceilings 4 to 8(100 to 203) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 16 (60,5) 10.6(0,73) 16(60,5) 10.6 (0,73) 4 to 8(10010203) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 12.0 (0,83) 17(64,3) 12.0 (0,83) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 15.0(1,0) 19(72) 15.0(1,0) 41/4 to 8(108 to 203) using F2 escutcheon, 4108(100 to 203) 20 x 20 (6,1 x 6,1) 20(6,1) 22 (83,2) 20.2 (1,4) 22 (83,2) 20.2 (1,4) using Fl escutcheon Technical Data: F1 Res 58 Pendent and Recessed Pendent (SIN R3513) Thread Nominal Orifice I Max. I I Sprinkler I I Max. Actual Sprinkler Size Inch (mm) I Pressure Temp. g Ratin Ambien t Temp. I K Factor I Length I °F I °C I °F °C psi (bar) I Inch (mm) ½' NPT (R/2) I ½' (13) I 175(12) 155 175 68 I I 79 I 100 150 I 38 I 66 5.8 (83.5) 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (1550Fi8ç) (175°F/790C) Ft x Ft (m x m) Ft (m) to Ceiling Spacing Flow Pressure Flow Pressure GPM (1/mm) PS( GPM (Llmin) PSI (bar) Inch (mm) Ft (m) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6 (0,53) 16(61) 7.6 (0,53) Smooth Ceilings 11/4 104(31.7 to 102) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6 (0,53) 16(61) 7.6 (0,53) 1 t 4(25.410 102) using Fl escutcheon. 16x 16(4,9x4,9) 16(4,9) 16(61) 7.6(0,53) 16(61) 7.6(0,53) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 10.8 (0,75) 19(72) 10.8 (0,75) 11/4 to l/4 (31.71044.4) using F2 escutcheon, 1 t 13/4 (25.4 to 20 x 20(6,1 X 6,1) 20(6,1) 22(83,3) 14.4(1,0) 22(83,3) 14.4 (1,0) 44.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 130 3. Techiikal Data: Fl Res 76 Pendent and Recessed Pendent (SIN R7618) fl prj I Max. Sprinkler I Max. K Sprinkler Nominal Orifice Pressure Temp. Rating Ambient Temp. I Length Si2 Inch (mm) psi (bar) Factor Inch (mm) I (ROA /32" (13.5) 175(12) 155 175 68 79 I 100 150 I I 38 66 7.6(109) I 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Max. Spacing (1550Fi80C) (175°F/790C) Top of Deflector to Ceiling Sin Flow Pressure Flow GPM Pressure Ft :)c Ft (m x m) Ft (m) Inch (mm) Ft (m) PSI (bar) (LMiin) PSI (bar) 12 12(3,6 x 3,6) 12(3.6) 21(79,5) 7.6(0,53) 21(79,5) 7.6 (0,53) Smooth Ceilings 41/4 to 8 (108 to 203) using F2 escutcheon. 14x 14 (4,3x4,3) 14(4,3) 21(79,5) 7.6(0,53) 1 21(79,5) 7.6(0,53) 4to8(100t0203) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 7.6 (0,53) 21(79,5) 7.6 (0,53) Beamed Ceilings per NFPA 3D, 13R or 13 installed in 8(2,4) 18x 16(5,5 x 5,5) 18(5,5) 21(79,5) 7.6(0,53) 21(79,5) 7.6 (0,53) beams 41/4 to 8(108 to 203) us- ing F2 escutcheon, 4 to 8(100 20 x 20(6,1 X 6,1) 20(6,1) 23(87,1) 9.2(0,63) 23(87,1) 9.2 (0,63) to 203) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Wlodel Fl Res 30, 49, 58 & 76 CCP Pendent* * Not listed for corrosion resistance. 2 5/8' [65.7mm] 0/A. 2 5/to" 0/A. HOLE /N CEILING [58.7mm] - cu° , ..- 1"x1/2" REDUCER CUP I / CEILING IIIj MAX. 'FACE OF FITTING J TO FACE OF CEILING DIMENSION COVER ADJUSTMENT I HEIGHT 3 5/16" 0/A. 135FC04E [84. /mm] Fl RES 30, 49, 58 & 76 CCP FEND. Fig. 3 Note: The Fl Res 76 will use a 1" x Y4" reducer. CCP Cover Plate Data: "A" "B" "C" Deflector Distance below bottom Cover Adjustment CCP Height of beam Inch (mm) Inch (mm) Inch (mm) 1/2 (12.7) 15/16 (24) ½ (13) - 1(25.4) 5/16(7,9) 3/4 (19) V2 (13)- 1(25.4) Model Fl Res 30, 49, 58 & 76 RrpccPd Pn1ent / FP N-' pusr1-or1I1r1rau-01 i suuui iui I 2 5/8" 0/A. [66.7mm] —HOLE IN CEILING - 2 5/16" 0/A. - [58.7mm] - CUP I I - I X 1/2 REDUCER CEILING I 7 1/2" 1[38. 1mm] MAX. FACE OF FITTING - "- TO FACE OF CEILING OIMENSION 1/2" [13mm] MAX. 'A" FP ADJUSTMENT Fl RES 49 PENDENT/FP Fig, 4 FP Escutcheon Data: "B" "A" Deflector Distance below bottom FP Position Inch (mm) of beam Inch (mm) Max. Recessed /16(11) Y2(12.7) Mm. Recessed /16 (24) 1 1(25.4) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. r,il Technical Data: F1 Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) Thread Nominal I Max. CCP Assembly Max. I K 1 I Sprinkler I Size Orifice Pressure I Rating Ambient Temp. I Factor Length I °F °C Inch (j) psi (bar) Inch (mm) I ½" NPT (R½) I 2l/" (8.2) 175(12) 135 100 38 3.0 (43.2) 2.25(57) Ordinary Temp. Rating Max. Coverage area Max. Spacing (1550F/68°C) Top of Deflector to Ceiling Minimum Ft x Ft (m x m) Ft (m) Inch (mm) Spacing Flow Pressure GPM (Llmin) PSI (bar) Ft (m) 12x 12(3,6x3,6) 12(3.6) 8(30,3) 7.0(0,48) Smooth Ceilings ½ to 1(13 to 25.4) using CCP. ½t0 1(13t025.4) using FPescutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 11(37,8) 13.4 (0,92) beams ½ to 1(13 to 25.4) using CCP. ½ to 1(13 to 25.4) using FP escutcheon. For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) Nominal CCP Max. Max. Thread Orifice Assembly Ambient K Sprinkler Size Inch Pressure Temp. Temp . Factor Length (mm) psi (bar) Rating Inch (mm) OF IOC OF IOC 112"NPT /16" (11) 175 (12) 135 57 100 38 4.9(70.6) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum Max. Spacing (155°F/68°C) Top of Deflector to Ceiling area FtxFt (in xin) Ft (in) Inch (mm) Spacing Ft (in) Flow Pressure GPM (Um in) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) Smooth Ceilings 1/2 to 1(13 to 25.4) using 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) CCP. '/2 to 1(13 to 25.4) using FP escutcheon. 16 x 16(4,9 x 4,9) 16(4.9) 14(53) 8.2 (0,56) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(13 to 25.4) using 8(2.4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68,1) 13.5(0,93) OCR ½ to 1(13 to 25.4) using FP escutcheon. 20 x 20 (6,1 x 6, 1) 20(6,1) 20(75,7) 1 16.7(1,14) 1 For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Thread Nominal I Max. I CCP Assembly I I Max. I K Sprinkler Size Orifice I Pressure Temp. Rating I Ambient Temp. i Factor Length OF . I °C I OF C Inch (mm) psi (bar) I I Inch (mm) ½" NFl (R½) 1/2" (13) 175(12) 135 57 100 ff38 5.8 (83.5) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum Max. Spacing (1550 80C) Top of Deflector to Ceiling area Ft x Ft (in x m) Ft (m Inch (mm) Spacing) Ft (m) Flow Pressure GPM (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6 (0,53) Smooth Ceilings '/2 to 1(13 to 25.4) using CCP. 1/2 to 1(13 to 25,4) using FP escutcheon, 14 x 14 (4,3 x 4,3) 14(4,3) 16(61) 7.6 (0,53) 16 x 16 (4,9 x 4,9) 16(4.9) . 16(61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1/2 to 1(13 to 25.4) using CCP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 19(72) 10.8 (0,75) Y2 to 1(13 to 25.4) using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) 14.4(1,0) For Ceiling types refer to NFPA 13, 13R or 13D r/" WALL DIMENSION FACE OF FITTING TO 1/4" MIN. 1.8mm] I [3 I 2 1/4" HOLE 0/A. - [5 7.2mm] [3 2mm] CEILING TO I DEFLECTOR ' X '/2" REDUCER DIMENSION 7, ~: 16 'DIAH 1 :[4.9.2mm] 2 27 /32" 0/A. [72.2mm] TURN - COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. —H 1/2' [13mm] IJ5FG05-O ADJUSTMENT El RES 58 & 44 HSW/F2 Fig. 5 Model Fl Res 44 & 58 Recessed HSW/F2 F2 escutcheon, 1/2' (13mm) adjustment Escutcheon, F2, Data: Face of Fitting 1 Type Adjustment to wall Inch (mm) Inch (mm) F2 V2(13) 3/16 - hh/;6 (4.7-17.4) ..'-.--'.-..-...'..-. ..•..c -j'--'-- - Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Temp. Rating I Ambient Temp. Length OF °C I OF °C HNPT Inch (mm) i psi (bar) I Factor Inch (mm) I [_(f3/4) /32" (13.5) 175 (12) J I 135 100 I 150 38 66 I 7.6 (109) I I 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing I (155°F/68°C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (1/mm) PSI (bar) 12 x 12(3.6 x 3,6) 12(3,6) 21(79,5) 7.6(0,53) Smooth Ceilings ½ to 1(13 to 25.4) using CCP. 1/2 to 1(13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 21 (79,5) 7.6 (0,53) 16 x 16 (4,9 x 4,9) 16(4,9) 21(79,5) 7.6(0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ o 1(13 to 25.4) using CCP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 22 (83,3) 8.4 (0,58) ½ to 1(13 to 25.4) using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 25(94,6) 10.8 (0,74) For (e11ing types reler to NFPA 13, 13R or 13D Model Fl Res 44 & 58 HSW Technical Data: F1 Res 44 HSW & HSW/F2 (SIN R3531) Thread Nominal I Max. I Sprinkler Max. Ambient K Sprinkler Size I Orifice I I Pressure I Temp. Rating ___________________ Temp Factor Length Inch (mm) psi (bar) Inch (mm) °F °C ½" NPT (R½) /8" (10) 175(12) 155 175 68 I 79 100 150 38 66 _OFIOC 4.4(63) 2.45(62) [;J Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F179°C) Top of Deflector to Ceiling Inch (mm) PSI (bar) Minimum Spacing Ft (m) Flow GPM (Umin) Pressure PSI (bar) Flow GPM (Um() Pressure 12 x 12 (3,6 x 3,6) 12(3,6) 12 (45,4) 7.5 (0,52) 12 (45,4) 7,5 (0,52) 4 to 6(100 to 152): ½(13) recessed using F2 escutcheon 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 14 (53,0) 10.2 (0,71) 14 (53,0) 10.2 (0,71) 16 X 16(4,9 x 4,9) 16(4,9) 16(60,6) 13.3(0,92) 16 (60,6) 13.3 (0,92) 16 x 18(4,9 x 5,5) 16(4,9) 18(68,1) 16.8(1,16) 18(68,1) 16.8 (1,16) 18 x 18(5,5 x 5,5) 18(5,5) 19(72,0) 18.7 (1,29) 19(72,0) 18.7 (1,29) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4( 1,89) 12 x 12(3,6 x 3,6) 12(3,6) 14(53,0) 10.2 (0,71) 14(53,0) 10.2 (0,71) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 14 x 14 (4,3 x 4,3) 14(4,3) 16(60,6) 13.3(0,92) 16(60,6) 13.3 (0,92) 16 x 16(4,9 x 4,9) 16(4,9) 17(64,4) 15.0(1,04) 17(64,4) 15.0(1,04) 16 x 18(4,9 x 5,5) 16(4,9) 20(75,7) 20.7(1,43) 20(75,7) 20.7(1,43) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4(1,89) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: Fl Res 5811SW & HSW/F2 (SIN R3533) Escutcheon, F2, Data: Nominal Max. Sprinkler Max. Sprinkler Face of Fitting Thread Orifice Ambient K Length Adjustment Pressure Temp. Rating Type to wall Size Inch Temp. Factor Inch Inch (mm) Inch (mm) ___________ psi (bar) (mm) °F I °C OF I °C (mm) ______ 3/18 -11/16 Y2' NPT 155 68 100 38 F2 /2(13) /2 (13) 175(12) 5.8 (83.5) 2.45 (62) (4.7- 17.4) ______ ____________ _______ ______________ (R'/2) 175 I 79 150 I 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (1550F168°C) (1750F/790C) Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) PSI (bar) 12 x 12(3,6 x 3,6) 12(3.6) 16(60,6) 7.6(0,53) 16(60,6) 7.6 (0,53) 4 to 6(100 to 152); 14 x 14 (4,3 x 4,3) 14(4.3) 18(68,2) 9.7(0,69) 18 (68,2) 9.7 (0,69) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 13.2(0,91) 21(79,5) 13.2(0,91) 112(13) recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 25 (94,7) 18.6(1,28) 25(94,7) 18.6 (1,28) 8(2,4) 16 x 20(4,9 x 6,1) 16(4,9) 29(109,8) 25.0 (1,73) 29(109,8) 25.0(1,73) 12 x 12(3,6 x 3,6) 12(3,6) 22(83,3) 14.4(l .0) 22(83,3) 14.4 (1,0) 6 to 12 (152 to 305): ½(13) recessed 14 x 14(4,3 x 4,3) 14(4,3) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 16 x 16 (4,9 x 4,9) 16(4.9) 26(98,4) 20.1(1,39) 26 (98,4) 20.1 (1,39) using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 31(117,4) 28.6 (1,97) 31(117,4) 28.6(1,97) or Ceiling types refer to NFPA 13, 13R or 13D 7. Model Fl Res 44 SWC * Not listed for corrosion resistance. TprihniiiI mitq. PlPac iM W( (SIN P'1i 4 to 12" Vt (10160mm To I I/4 (31.75mm) Mo,im*m 304.80mm) 1mm Of fUtng To WolF O,,ne**,on PUSH ON COVER. THEN 11)6W TO ADJUST UNTIL flGHT ADAINTIT WALL. IX I/2 Rd** R000mmood;0 ri -:• (8Am) TURN COLLAR uNnL I7CHT AGAINST SPRINKLERWRENCH 121/32 BOS S. [42.07-] El RES 44 SWC Fig. 6 * Nominal Max. Cover I Max. I Sprinkler Thread Orifice Pressure Temp. I Ambient K Length Size Inch (mm) psi (bar) Rating I Temp. Factor Inch (mm) Y2" NPT (R½) /8" (10) 175(12) 135 57 100 38 4.4(63) 2.45(62) Ordinary Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (l55mFI68°C) Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49,2) 8.7 (0,60) 4t06(100to 152); 14 x 14 (4,3 x 4,3) 14(4,3) 14 (53,0) 10.2 (0,71) 16 x 16 (4,9 x 4,9) 16(4,9) 17 (64,3) 15.0(1,1) ½ (13) recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 19(71,8) 18.7(1,13) 8(2,4) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4(l.89) 12 x 12(3,6 x 3,6) 12(3,6) 14(52,9) 10.2 (0,71) 6 to 12 (152 to 305); ½ (13) recessed 14 x 14(4,3 x 4,3) 14(4,3) 15(56,7) 11.7(0,81) 16 x 16(4,9 x 4,9) 16(4,9) 18(68,1) 16.8(1,16) using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 20(75,6) 20.7 (1,43) For Ceiling types refer to NFPA 13, 13R or 13D 91 MndcI I(PcccR I-lWY (I iriLr\ Technical Data: Fl Res 58 HSWX (SIN RA3533) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure I Temp. Rating ___________ Temp. _________ Factor Length Identification Inch (mm) j psi (bar) Inch (mm) OFb OC Number (SIN) °F bc Bulb Y2" NPT (R½) V2" (13) 175(12) 155 175 I 68 79 100 150 38 I 66 5.8 (835) 2.45 (62) RA3533 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F168°C) Intermediate Temp. Rating (175°Ff79°C) lop of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (1/mm) Pressu re PSI (bar) 18 x 20 (5,5 x 6,1) 18(5,5) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4t06(100to 152); /2 (13) recessed using F2 escutcheon 8(2,4) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26,8(l.85) 16 x 22 (4,9 x 6,7) 16(4,9) 33(125) 32.4 (2,23) 33(125) 32,4 (2,23) 16 x 24 (4,9 x 7,3) 16(4,9) 38(144) 42.9 (2,96) 38(144) 42.9 (2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4 (3,75) 42(160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18(5,5) 35(133) 36.4 (2,5) 35(133) 36.4 (2,5) 6 to 12 (152 to 305); 1/2 (13) recessed using F2 escutcheon 16 x 22 (4,9 x 6,7) 16(4,9) 38(144) 42.9 (2,96) 38(144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42(160) 52.4(3,6) 42(160) 52.4 (3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9 (4,34) 46(174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 130 MndcI Fl SR HWY (RiiIh FACE OF FITTING To WALL DIMENSION - 2 1/4' HOLE 0/A. [5 7.2mm] IX 1/2" REOUCER - I 15/16OIA.j -F - i TURN COLLARCOLLAR UNTIL '' TIGHT AGAINST SPRINKLER WRENCH BOSS. I35FCO8 —H --1 11/16" MIN. '-I [318mm] I 1/8" I CEILING TO [3.2mm] DEFLECTOR I DIMENSION _ I 2 27/32' 0/A. [72.2mm] 1/2" [13mm] ADJUSTMENT Fl RES 58 HSWX Fig. 7 0 Technical Data: KRes58 HSWX (RA3593) I Nominal Max. Max. Sprinkler Sprinkler Thread I I Orifice Pressure Ambient K Length Identification Size Inch (mm) I J psi (bar) Temp. Factor Inch (mm) Number (SIN) °F Link 112" NPT 1/2" (13) 175(12) 100 (R 112) 38 5.8 (83.5) 2.45 (62) RA3593 Ordinary Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (165°F174°C) Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) 18 x 20 (5,5 x 6, 1) 18(5,5) 29(109) 25(1,72) 4 to 6(100 to 152); 20 x 20 (6,1 x 6,1) 20(6,1) 30 (114) 26.8(1,85) 16 x 22(4,9 x 7,3) 16(4,9) 33(125) 32.4 (2,23) ½ (13) recessed using F2 escutcheon 16 x 24 (4,9 x 7,3) 16(4,9) 38(144) 42.9 (2,96) 8(2,4) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4 (3,75) 18 x 20 (5,5 x 6, 1) 18(5,5) 35(133) 36.4(2,5) 6 to 12 (152 to 305); Y2 (13) Recessed 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9(2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42(160) 52.4(3,6) using F2 escutcheon 14 x 26(4,3 x 7,9) f 14(4,3) 46(174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model Fl Res 30, 49, Fl Res 58, Fl Res 76 and Fl Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guide- lines and the applicable installation standard. Deflector- to-ceiling distance listing shall be l"to 8" maximum, only for FlRes 49. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish- specify]. Resi- dential pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58, SIN R351 1, R3516 & R3513 (Bulletin 135). Model Fl Res 49 & 58 Recessed Pendent/Fl, Model Fl Res 30, 49 & 58 Recessed Pendent! F2, Model Fl Res 30,49 & 58 Recessed Pendent/ FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-F)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector-to-ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded *DuPont Registered Trademark 10. o r cold head cup with 3 mm glass bulb containing no p lastic parts, and having a temperature rating of [155°F (8°C)] [175°F (791C)]. Sprinklers shall have a nomi- nl K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish— spec- ify]. Recessed escutcheon assembly shall be a steel, tv.Io-piece escutcheon [with ½" adjustment (Model F2)] [v'th 3/4" adjustment (Model Fl)] [of push-on and thread off design with 1/2" adjustment (Model FP)]. Standard fin- is h shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Vodel Fl Res 30, 49 & 58 Recessed Pendent/F1] [Model El Res 30, 49 & 58 Recessed Pendent/F2] [Model Fl Res 30,49 & 58 Recessed Pendent/FP] SIN R351 1, R3516 & R3513 (Bulletin 135). IViodel Fl Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 44, Fl Res 58 Horizontal Sidewall, Fl Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- *DuPont Registered Trademark 11. leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (740C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed. The Fl Res 58 HSW is also available with low lead frame, Fl Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and Fl Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish— specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, Fl Res 58, Fl Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish— specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3%" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). I Model Fl Res 76 Recessed Pendent/Fl, Model Fl Res 76 Recessed Pendent/F2, Model Fl Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7,6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish- specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjust- ment (Model F2)] [with 3/4" adjustment (Model El)] [of push-on and thread off design with 1/2" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent/ Fl] [Model Fl Res 76 Recessed Pendent/F2] [Model Fl Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/1t2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (570C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. J. Concealed pendent sprinklers shall be Reliable Model Fl Res 76 CCP, SIN R7618 (Bulletin 135). Finishes (1) Standard Finishes Sprinkler F1 F2 FP Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black White Painted Polyester(') Coated Special Application Finishes Sprinkler Fl, F2, FP Escutcheons Electroless Nickel PTFE(Teflon)(2) Electroless Nickel PTFE (Teflon) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Chrome Dull Chrome Dull (1) Other finishes and colors are available on special order. Consult factory for details. cULus listed Corrosion Resistant Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Cover Plate Finish *DuPont Registered Trademark The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the united States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. A121111, Recycled lieliabl (800) 431-1588 Sales Offices %V Paper (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 06/15 P/N 9999970235