HomeMy WebLinkAbout2708 GATEWAY RD; ; FPC2017-0172; Permit4Cityof PERMIT REPORT . Cd, rlsbad Print Date: 10/21/2021 Permit No: FPC2017-0172 Job Address: 2708 GATEWAY RD, CARLSBAD, CA 92009-1730 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132631100 Track #: Applied: 06/21/2017 Valuation: $358,824.65 Lot #: Issued: 08/10/2017 Occupancy Group: Project U: Finaled Close Out: 09/13/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: Description: C3 KIDS CHURCH BLDG C -SPRINKLER (116) FPContractor: INDUSTRIAL FIRE SPRINKLER CO INC 3.845 IMPERIAL AVE SAN DIEGO, CA 92113-1702 (619) 266-6030 FEE AMOUNT FIRE NFPA 13 System> 100 heads (includes 1 riser) $832.00 FIRE Reinspection (per inspection) $187.00 Total Fees: $1,019.00 Total Payments To Date: $1,019.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov INDUSTRIAL FIRE SPRINKLER CO., INC. CA LIC.C-16 558084 HI LIC. C-20351 Co LIC. 11-1058 UT LIC. 7336958-5501 VA LIC. 2705 125390A C3 KIDS CHURCH 2708 GATEWAY ROAD CARLSBAD, CA 92008 HYDRAULIC CALCULATIONS MATERIAL LIST TECH DATA FILE COPY FPC20I7-0172 2708 GATEWAY RD 3845 Imperial Ave., San Diego, CA., 92113 Phone (619) 266-6030 Fax (619) 266-6035 iarauiic uaicuiations for Project Name: C3 Kids Church 0 Location: 2708 Gateway Rd., Carlsbad, CA 92008, Drawing Name: Fire Sprinkler Piping Plan.cad 0 Calculation Date: 6/10/2017 Design Remote Area Number: Remote Area Location: Occupancy Classification Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: Type of System: In-rack Demand: Hose Streams: 1 Kids Activity Area Light Hazard 0.l0gpm/ft2 1500.00ft2 (Actual 1 558.50ft2) 196.00ft2 Upright 17 Wet Volume of Dry or PreAction System: N/A gpm at Node: N/A 100.00 at Node: 1 Type: Allowance at Source N/A Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 518.86 @96.36 Water Supply Information: Name of Contractor: Kingdom Builders Address: 2588 El Camino Real Suite# F337, Carlsbad, CA 92008 Phone Number: 760-855-6331 Name of designer: Freddy Atcaraz Authority Having JurisdictionCity of Carlsbad Fire Department Notes: k@ M.E.P.CAD, Inc. AutoSPRlNK® 12 02.0.61.0 1 6/10/201711:09:02AM Page 1 Actual Fl Minimum Flow Device (gpm) (gpm) K-Factor (K) Job Ha Report Descriptiort b:Z8( iIire (psi) Sprinkler 151 28.52 19.60 5.6 25.93 Sprinkler 152 26.55 19.60 5.6 22.48 Sprinkler 153 25.60 19.60 5.6 20.90 Sprinkler 154 25.69 19.60 5.6 21.05 Sprinkler 155 32.77 19.60 5.6 34.24 Sprinkler 156 27.48 19.60 5.6 24.07 Sprinkler 157 24.59 19.60 5.6 19.29 Sprinkler 158 22.87 19.60 5.6 16.68 Sprinkler 159 22.03 19.60 5.6 15.48 Sprinkler 160 22.11 19.60 5.6 15.59 Sprinkler 16.1 . 32.09 . 19.60 5.6 32.83 Sprinkler 162 25.64 19.60 5.6 20.96 Sprinkler 163 21.36 19.60 5.6 14.56 Sprinkler 164 21.93 19.60 5.6 15.33 Sprinkler 165 20.36 19.60 5.6 13.21 c Sprinkler 166 19.60 19.60 5.6 12.25 Sprinkler 167 19.67 19.60 5.6 12.34 c Most Demanding Sprinkler Data f,©M.E.P.CAD, Inc. AutoSPRlNK®12v12.0.61.0 6/10/2017 11:09:04AM Page 3 emote Area Number: 1 Date: 6/10/2017 - Pipe Information Elev I Flow added Fittings & Length i C Total(Pt) Notes Jode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Equiv. Fixed Pressure Losses, when Fitting (Foot) Pf Friction Loss Per Unit'applicable, Elev(Pe) Elev 2 Total Flow 'ode 2 (Foot) Actual ID Length (psi) are added directly Total (Foot) Friction'P to (P1) and shown as a (Foot)negative value. 166 18'-11 5.6 19.60 1 (See '-6 120 0 • 12.25 ' Route 1 Sprinkler, Notes) T(5'-O) 5'-O 0.125357 0.22 116 18'-5 19.60 1.0490 5• 0.69 116 18'.5 19.67 1% 8-6 120 13.16 Flow (q)from Route 2 0119267 115 18-5 3927 13800 8'-6 101 115 18'-5 20.36 1 8'-71/2 120 14.17 Flow (q) from Route 3 0.258254 114 18-5 5963 13800 8-71/2 223 114 18'5 21.93 1/4 1 1 1/2 120 16.40 Flow (q) from Route 5 0 460947 113 18-5 8156 13800 1-1% 051 113 185 21.36 1% 7'-7% 120 16.91 Flow (q) from Route 4 0.708901 112 18-5 1 R. 10292 13800 IMM711--R~ 771/ 540 112 18'-5 25.64 1% (See 6'-5 120 22.31 _____ __ Notes) Flow (q)from Route 11 6'-0 PI 56 18-5 128.56 1.3800 1.069746 T(6 -0) 12-5 13.28 56 18'-5 32.09 1% c. (See 1'-8 ________ 120 35.59 Notes) Flow (q) from Route 16 PO 6-0 1.615440 0.72 55 16'-9 160.64 1.3800 -8 7'-8 12.39 55 16-9 3 12'-0 120 48.69 0.024555 53 16'-9 160.64 3.2600 12'-0 0.29 53 16'-9 151.86 3 12'-O 120 48.99 Flow (q) from Route 6 51 16-9 31250 84092 32600 12'0 101 51 16'-g 106.36 3 82'-3% 120 50.00 Notes) Flow (q)from Route 10 3fE(6'-8%) 20'-2 4.28 6'-1 O% 418.86 10 0.144581 3.2600 102-51/2 14.82 10 6'-10Y2 3 (See 7'-8 120 69.09 Notes) 48'-4% 2.77 5 0-6 rtsr 418 86 32600 0.144581 2f(-0.00),CV(21-6), 56-1 8.11 BV(13 5V2) 2M(6-8%) , © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 1 6/10/2017 11:09:05AM Page 4 emote Area Number: 1 Date: 6/10/2017 Pipe _Information Elev i Flow added Fittings & Length C Factor Total(Pt) Notes lode 1 (Foot) K-Factor this step Nominal ID es (Foot) Fitting/Device (Equivalent Equiv. Length) Fixed Pressure Losses, when applicable, are added directly Fitting (Foot) Pf Friction Loss Per Unit Elev(Pe) Elev 2 Total Flow Friction(PU lode 2 (Foot) Actual ID Length (Foot) ( Total (ps to (Pf) and shown as a (Foot) negative_value. 5 0'-6 4 (See 3'-6 140 79.96 Notes) 17-11 0.028873 1.52 21'-5 0.62 4 -3'-O 418.86 4.2800 E(17'-11) 4 4-0 4 (See 11'2 150 82.10 Notes) 19-2% 3 4-0 418.86 4.2300 0.026910 E(19'2%) 30'-4% 0.82 3 -3'-O 4 (See 7'O 140 82.92 Notes) BFP(-12.00), E(17'-11) 17-11 0.028873 -3'-O ~im2 418.86 4.2800 24'-11 12.72 2 -3-0 4 (See 27'0 150 95.64 Notes) Water Supply 0.026910 I -31-0 418.86 4.2300 27'-O 0.73 100.00 96.36 Hose Allowance At Source i 518.86 Total(Pt) Route I 167 18'-11 5.6 19.67 1 (See 0'-6 120 12.34 •••.' Route 2'.... Notes) Sprinkler, E(2-0) 2-0 0126225 0.22 117 18-5 1967 1.0490 2'-6 032 117 18'-5 Iv4 8'6 120 12.87 0033198 116 18-5 IN 1967 13800 8 6 028 13.16 Total(Pt) Route 2 165 18'-11 5.6 20.36 1 (See 0'6 120 13.21 •• Route 3•'• Notes) Sprinkler, T(5'-O) 6-0 0.134454 0.22 115 18'-5 20.36 1.0490 5'-6 0.74 14.17 Total(Pt) Route 3 163 18'-11 5.6 T 21.36 1 (See 4'61/2 120 14.56 ••• Route 4•••.• Notes) Sprinkler, 10-0 0.22 113 18-5 21.36 1.0490 0147035 2T(5-0) 14'-61/2 214 16.91 Total(Pt) Route 4 164 18'-11 5.6 T 21.93 1 (See 0'-6 120 15.33 ..... Route 5••• Notes) Sprinkler, T(5'-O) 50 0.154285 0.22 114 18'-5 21.93 1.0490 5'-6 0.85 ,©M.E.P.CAD, Inc. AutoSPRlNK®12v12.0.61.O 1 6/10/2017 11:09:05AM Page 5 mote Area Number: 1 Date: 6/10/2017 Pipe _Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes lode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Equiv. Length) xed Pressure Losses, when Fitting (Foot) tion Loss Per Unit Elev(Pe) Total Flow lode 2 Actual ID Length l added directly (Foot) (psi) Friction(Pf) to (P1) and shown as a (Foot) negative value. 16.40 Total(Pt) Route 5 159 18'-11 5.6 22.03 1 (See 0'-6 120 15.48 Route 6•• Notes) Sprinkler, T(5'-O) 5-0 0.155648 5' 6 0.22 109 18'-5 22.03 1.0490 0.86 109 18'-5 22.11 11/4 8'-6 120 16.55 Flow (q) from Route 7 0.148077 18's kgg108 ED 44.15 1.3800 8'-6 1.26 108 18'-5 22.87 1% 8'-61/2 120 17.81 Flow (q) from Route 8 0320522 107 18-5 6701 13800 8-6% 274 107 18'-5 24.59 1y4 8'9Y2 120 20.55 Flow (q) from Route 9 0571518 106 18'-5 91.61 1.3800 8-9/2 5.02 106 18'-5 27.48 11/4 (See 65 120 25.58 Notes) Flow (q) from Route 14 54 18-5 11909 13800 0928507 1(6-0) 1153 54 18'-5 32.77 1Y4 (See 1'8 120 37.11 Notes) Flow (q) from Route 17 6-0 0.72 53 16'-9 151.86 1.3800 7'B 1.455774 11.16 PO(6'-O) 48.99 Total(Pt) Route 6 160 18'-11 5.6 22.11 1 (See 0'-6 120 15.59 ••••'Route 7••••' Notes) Sprinkler, E(2'-O) 2-0 0.156708 0.22 110 18'-5 22.11 1.0490 2'-6 0.39 110 18'-5 i1/ 8'-6 120 16.20 0.041215 109 18'-5 2211 13800 8'-6 0.35 16.55 Total(Pt) Route 7 158 18'-11 5.6 22.87 1 (See 0'-6 120 16.68 .... Route 8••••• ____________________ ________ Notes) Sprinkler, T(5'-O) 5-0 0.166755 0.22 108 18'-5 22.87 1.0490 66 0.92 17.81 Total(Pt) Route 8 ,©M.E.P.CAD, Inc. jAutoSPRlNK®12v12.0.61.O 1 6/10/2017 11:09:05AM Page 6 153 18'-1I 5.6 25.60 1 (See 0'6 120 Notes) 5-0 0.205455 5-6 103 18'-5 25.60 1.0490 103 18'-5 25.69 8'-6 120 0195448 102 18-5 51.29 1.3800 8'-6 102 18'-5 26.55 11/4 85.61/2 120 0.422864 101 18-5 77.84 1.3800 , 8-6% 101 18-5 28.52 11/4 (See 1621/2 120 Notes) 6-0 0.753312 21'-21/2 52 18'-5 106.36 1.3800 52 18'-5 1% (See 18 120 Notes) 6-0 0.753312 51 16-9 106.36 1.3800 7-8 162 18'-11 5.6 25.64 1 (See Notes) 0'6 120 5-0 0205997 112 18-5 2564 1.0490 6-6 154 18'-11 1 5.6 25.69 1 (See Notes) 0'6 120 2'0 0206824 104 18-5 2569 10490 2'-6 104 18-5 1% 8'-6 120 0054396 103 18-5 li 2569 1 13800 8 6 -. Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as a negative value. Elev(Pe) Friction(Pf) 19.29 •'• Route 9''••' Sprinkler, 1.05 0.22 20.55 Total(Pt) Route 9 20.90 ***--Route 10'•••• Sprinkler, T(5'-O) 0.22 1.13 22.24 Flow (q) from Route 12 1.66 23.91 Flow (q) from Route 13 3.62 27.53 Flow (q) from Route 15 T(6'-O) 15.97 43.50 PO(6'-O) 0.72 5.78 50.00 Total(Pt) Route 10 20.96 •••••Routell'''•' Sprinkler, T(5'-O) 0.22 1.13 22.31 Total(Pt) Route 11 21.05 ''"'Route 12''..' Sprinkler, E(2-O) 0.22 0.52 21.78 0.46 22.24 Total(Pt) Route 12 Pipe Information Elev 1 Flow added Fittings & Length C Factor 4ode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) (q) Equiv. Fitting (Foot) Pf Friction Loss Per Unit Elev 2 Total Flow Total Jade 2 (Foot) (Q) Actual ID (psi) (I::) 157 18'-11 5.6 24.59 1 (See 0'6 120 Notes) 1.0490.5-6 - 0190778 107 18-5 2459 11- .JI I I_i I ISIS emote Area Number: 1 Date: 6/10/2017 ,©M.E.P.CAD, Inc. jAutoSPRINK®12v12.O.61.0 1 6/10/2017 11:09:05AM Page 7 11.1 IC4$ll¼... %.JJ IWaO S.J$I%Ap*..,II emote Area Number: I Date: 6/10/2017 W Pipe _lnformati ode 1 Elev i (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Length (Foot) Length (Foot) C Factor Total(Pt), Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value. Fitting Pf Friction Loss Per Unit (psi) Elev(Pe) 1ode 2 Total Flow Actual ID (Foot) Friction(Pf) 152 18'-11 5.6 26.55. 1 (See Notes) 0'-6 120 22.48 .. '• Route 13..... Sprinkler, T(5'-O) 5-0 0.219806 0.22 .102 18'-5 26.55 . 1.0490. 5'-6 1.21 23.91 Total(Pt) Route 13 156 18'-l1 1 5.6 27.48 1 (See Notes) 0'6 120 24.07 ..... Route 14 ..... Sprinkler, T(5'-O) 5-0 0.234188 0.22 106 18'-5 27.48 1.0490 6-6 1.29 25.58 Total(Pt) Route 14 151 18'-11 5.6 28.52 ______________ 1 ________ (See Notes) 0'-6 120 25.93 . ... Route 15..... Sprinkler, T(5'-0) . -0 0.250833 0.22 101 _________ 18'-5 ___ 28.52 1.0490 5'6 1.38 27.53 Total(Pt) Route 15 161 18'-l1 5.6 32.09 1 (See Notes) 0'-6 120 32.83 .... Route 16..... . Sprinkler, T(5'-O) 5-0 0.311987 0.22 111 18'-5 32.09 1.0490 5'-6 1.72 111 18'-5 11/4 (See Notes) 4'l 120 34.76 T(6'-O) 6-0 0.082055 56 18'-5 32.09 1.3800 10-i 0.83 35.59 Total(Pt) Route 16 155 18'-11 5.6 32.77 1 (See Notes) 0'-6 120 - 34.24 ----.*Route 17..'.' Sprinkler, T(5'-O) 5-0 0.324428 0.22 105 18'-5 32.77 1.0490 5'.6 1.78 105 18'-5 11/4 __ (See Notes) 4'l 120 36.25 T(6 -0) 6-0 0.085326 54 18-5 32.77 1.380 10-1 0.86 37.11 Total(Pt) Route 17 ,©M.E.P.CAD, Inc. ]AutoSPRlNK®12v12.0.61.0 1 6/10/2017 11:09:05AM Page 8 I flit 1- Si'.? I SISIO Sit 1141 I_il I emote Area Number: 1 Date: 6/10/2017 IiiiLr Actual Inside Diameter 487 F cto 7(Schedule 40 Steel Pipe Inside Diameter) Factor Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 450 Elbow Eel 11 %° Elbow Ee2 221,40 Elbow f Flow Device fd Flex Drop FDC Fire Department Connectic fE 90° FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PlV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° I Tr Tee Run U Union WirF Wirsbo I WMV Water Meter Valve I Z Cap ,©M.E.P.CAD, Inc. AutoSPRlNK®12v12.0.61.0 1 6/10/2017 11:09:05AM Page 9 Jot Re 15C 135 120 105 90 (0 a. :: 45 30 15 Hydraulic Graph Name: C3 Kids Church N 1.85 note Area Number: I Date: 6/10/2017 Water Supply I Summary Sheet [_ Node:1 Available Supply Static Pressure 124.00 518.86 123.87 - - - -......... 500.00 @ 117.00 4186 f 95.36 518.86 with Hose Allowance at Source System demand curve _..-II1.1Jj_1..jJJ .lIIIIllI I!I!IIltl IllIllIul 111111111 liii II I I 11111 III I I I I I I I I - 0900 1800 2700 3600 4500 5400 6300 7200 8100 9000 Flow - gpm ) ) 1S.© M.E.P.CAD, Inc. rfl AutoSPRINK® 12 02.0.61.0 6/10/2017 11:09:03AM Page 2 1-jycirauluc aIcuIations for Project Name: C3 Kids Church Location: 2708 Gateway Rd., Carlsbad, CA 92008, Drawing Name: Fire Sprinkler Piping Plan.cad Calculation Date: 6/10/2017 Design Remote Area Number: Remote Area Location: Occupancy Classification: Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: 2 Classroom I & 2 Light Hazard 0.logpm/ft2 1500. 00ft2 (Actual 990.03ft2) 196.00ft2 Pendent 12 Type of System: Wet Volume of Dry or PreAction System: N/A In-rack Demand: N/A gpm at Node: N/A Hose Streams: 100.00 at Node: I Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 386.46 @83.87 Water Supply Information: Name of Contractor: Kingdom Builders Address: 2588 El Camino Real Suite# F337, Carlsbad, CA 92008 Phone Number: 760-855-6331 Name of designer: Freddy Alcaraz Authority Having Jurisdictioncity of Carlsbad Fire Department Notes: © M.E.P.CAD, Inc. AutoSPRlNK® 12 02.0.61.0 2 6/10/201711:13:23AM Page 1 Actual FI• - Minimum Flow Device (gpm) (gpm) K-Factor (K) Job Number: 17-872 Report Description Light Hazard (2) P re (psi) Sprinkler 251 30.00 19.60 5.6 28.70 Sprinkler 252 26.86 19.60 5.6 23.00 Sprinkler 253 25.47 19.60 5.6 20.68 Sprinkler 254 24.29 19.60 5.6 18.81 Sprinkler 255 24.33 19.60 5.6 18.87 Sprinkler 256 28.58 19.60 5.6 26.04 Sprinkler 257 23.38 19.60 5.6 17.43 Sprinkler 258 22.35 19.60 5.6 15.93 Sprinkler 259 21.04 19.60 5.6 14.12 Sprinkler 260 20.93 19.60 5.6 13.97 c' Sprinkler 261 19.60 1.9.60 5.6 . 12.25 Sprinkler 262 19.64 19.60 5.6 12.31 Most Demanding Sprinkler Data ©M.E.P.CAD, Inc. AutoSPRINK®12v12.0.61.0 6/10/2017 11:13:25AM Page 3 .dLl I flAP I I'... .JJ 8 .I%JO '.JI ILlS LIPS emote Area Number: 2 Date: 6/10/2017 W Pipe Information Op Node 1 Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot' Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value. Fitt Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) 2 Elev 2 (Foot) R-11Mode .. Total Flow (Q) Actual ID Total (Foot) Friction(PU 261 10'-O% 5.6 19.60 1 (See Notes) 37'-4% 120 12.25 Route I Sprinkler, E(2'-O), 2T(5' -O) 12'- 0.125357 - 211 .18'-5 19.60 1.0490 61 211 • 18-5 19.64 1 ' 14'-6 120 14.80 Flow (q) from Route 2 0.119104 210 18-5 3924 13800 14'6 173 2 10 18'-5 20.93 1 2-6% 120 16.53 Flow (q) from Route 3 0262614 209 18'-5 6017 13800 26% 067 209 18-5 21.04 1 3- 120 208 17. Flow (q) from Route 4 0457362 208 18-5 Yk 8121 13800 3-8 169 208 18-5 22.35 1/4 5-1 % 120 18.88 Flow (q) from Route 5 0.717066 207 18•-5 103.56 1.3800 51 11/ 3.66 207 185 23.38 1/4 6-5 120 22.55 Flow (q) from Route 6 T(6-0) 1.044960 60 18'-5 126.94 1.3800 12-5 12.97 60 18-5 28.58 1% V-8 120 35.52 Flow (q) from Route 11 PO(6'-O) 6-0 1.521322 0.72 59 16-9 15552 1.3800 7-8 11 66 59 16-9 3 10-0 120 47.90 023124 0.023124 1-0 57 16-9 15552 32600 10-0 023 57 169 130.94 3 115-9% 120 48.14 Flow (q) from Route 7 3fE(6'-8%) 20-2 0071589 4.28 10 6 10% - 28646 32600 135-11% 9.73 10 6'-101/2 3 (See Notes) 7'8 120 62.15 2f(-0.0O), CV(21-6), BV(13'-5%), 2fE(6-81/2) 48'-41/2 0.071589 2.77 5 0,-6 286.46 3.2600 56-1 4.01 5 0-6 4 (See Notes) 3'6 140 68.93 E(17-11) 17-11 0014297 1.52 4 3-0 28646 T47.2800 21-5 031 ,©M.E.P.CAD, Inc. ]AutoSPRINK®12v12.0.61.0 2 6/10/2017 11:13:26AM Page 260 101-0 5.6 20.93 1 (See Notes) 3610 120 7-0 0.141515 210 18'-5 20.93 1.0490 43'10 259 10-0% 5.6 21.04 1 (See Notes) 350 120 12'-O 0.142956 209 18'-5 21.04 1.0490 47'0 258 101-0 5.6 22.35 1 (See 34'3% 120 Notes) 7-0 208 18'-5 22.35 1.0490 41'-3% 0.159790 11.1 I C4I I IL.. SJL? I R..1O .II 11.1$ *111 emote Area Number: 2 Date: 6/10/2017 W ripe Information Elev I Flow added Fillings & Length C Factor Jode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Filling (Foot) Pf Friction Loss Per Unit (q) Equiv. Elev 2 Total Flow Total 4 d 2 ode (Foot) Actual ID Length (psi) (Foot) (Foot) 4 3'0 4 (See 11 '-2 150 Notes) 19-2/2 3 -3-o 286.46 4.2300 0.013325 30'-4Y2 3 4-0 4 (See 7'-O 140 Notes) 17-Il 0.014297 2 4-0 286.46 4.2800 24'-11 2 30 4 (See 27'-0 150 Notes) 0013325 1 -3'-0 28646 42300 27-0 100.00 1 386.46 262 10'- 01/2 5.6 19.64 1 (See 37'6 120 __ Notes) 9.0 0.125881 46-6 212 18'-5 19.64 1.0490 212 18'-5 iy4 8'6 120 0.033107 211 18'-5 19.64 1.3800 8-6 ' MW Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value. Elev(Pe) Friction(Pf) 70.75 E(19'-2%) 0.40 71.16 BFP(-12.00), E(17'-11) 12.36 83.51 Water Supply 0.36 83.87 Hose Allowance At Source Total(Pt) Route 1 12.31 • • • 'Route 2 • • • • Sprinkler, 2E(2'-O) T(5'-O) -3.64 5.86 14.52 0.28 14.80 Total(Pt) Route 2 13.97 •• '• Route 3''''' Sprinkler, E(2'-0), T(5'-O) -3.64 6.20 16.53 Total(Pt) Route 3 14.12 ..... Route 4''''' Sprinkler, E(2'-O), 2T(5'-O) -3.64 6.72 17.20 Total(Pt) Route 4 15.93 ''''Route 5•••'' Sprinkler, E(2'-0), T(5'-O) - -3.64 6.60 18.88 Total(Pt) Route 5 - ,©M.E.P.CAD, Inc. AutoSPRlNK®1202.0.61.0 2 6/10/2017 11:13:26AM Page 5 a&i I Nut I 1¼.. ¼/%J I .I¼4O sjt 11.11 I_tI I emote Area Number: 2 Date: 6/10/2017 W Pipe Information OF Elev 1 Flow added Fittings & Length C Factor Total(Pt) Notes Mode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent I Equiv. Length) Fixed Pressure Losses, when Fitting (Foot) Loss Per Unit Elev(Pe) Elev 2 Total Flow 1ode 2 Actual ID Length Si applicable, are added directly Total (Foot) (Foot) (Foot) Friction(Pf) to (P1) and shown as a negative value. 257 10'-0Y2 5.6 23.38 1 (See 38'5 120 17.43 Route 6 • Notes) Sprinkler, E(2-0), 2T(5'-O) 12-0 0.173695 -3.64 207 18'-5 23.38 1.0490 50'-5 8.76 22.55 Total(Pt) Route 6 254 10'-O% 5.6 24.29 1 (See 36-6 120 18.81 . • . Route 7 Notes) Sprinkler, 12-0 -3.64 204 18'-5 24.29 1.0490 47'6 0.186423 -6 .186423 8.85 E(2'-O), 2T(5'-O) 204 18'-5 24.33 1/4 171 01,4 120 24.03 Flow (q) from Route 8 0.177013 203 18'-5 48.62 1.3800 17'01,4 3.02 203 18'-5 25.47 1% 8'-9% 120 27.05 Flow (q) from Route 9 0.385852 202 18'-5 74.08 1.3800 8'-9% 3.39 202 18-5 26.86 1Y4 (See 6'5 120 30.44 Notes) Flow (q) from Route 10 T(6'-O) 6'-0 0.683866 58 18-5 100.94 1.3800 12'-5 8.49 58 18'-5 30.00 1% (See 18 120 38.93 Notes) Flow (q) from Route 12 6'-O 0.72 57 16'-g 130.94 1.3800 1.106744 '0(6'0) 7'-8 8.49 48.14 Total(Pt) Route 7 255 10101,4 5.6 24.33 1 (See 35-9Y2 120 18.87 ***-*Route 8 Notes) Sprinkler, 2E(2 0) T(5 0) 91 0 0.186967 -3.64 205 18' 5 24 33 1 0490 8 38 205 18'-5 j1/4 8'-6 120 23.61 0049174 204 18-5 2433 13800 86 042 24.03 Total(Pt) Route 8 253 101-0Y2 5.6 25.47 1 (See 37'-2 120 20.68 ' • • Route 9 Notes) Sprinkler, 12'-0 -3.64 203 18'-5 25.47 1.0490 0.203467 E(2'-O), 2T(5'-O) 49'-2 10.01 27.05 Total(Pt) Route 9 ,©M.E.P.CAD, Inc. P.3,g AutoSPRlNK®12v12.0.61.0 2 6/10/2017 11:13:26AM Page 6 lid IlCilil'..,. '.J%J 1S1¼40 '.jltUflsll emote Area Number: 2 Date: 6/10/2017 W Pipe Information Elev i Flow added Fittings & Length C Factor Total(Pt) Notes 'ode 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent (q) ________ Equiv. Length) Fixed Pressure Losses, when Fitting (Foot) . Pf Friction Elev(Pe) lode 2 Elev 2 Total Flow Actual ID Length Loss Per Unit applicable, are added directly (Foot) (Foot) (Foot) Total (ps ' Friction(Pf) to (P1) and shown as a negative value. 252 10'-O% 5.6 26.86 1 (See 37'4 120 23.00 .... Route 10. Notes) Sprinkler, 12'-0 -3.64 202 18'-5. 26.86 1.0490 0.224533 E(2-O), 2T(5'-o) 11.08 30.44 Total(Pt) Route 10 256 10'- 01/2 5.6 1 28.58 1 (See 37'5% 120 26.04 Route 11 Notes) Sprinkler, E(2 0) 2T(5 0) 12'-0 0251798 -3.64 206 18-5 2858 1 0490 1245 206 18'-5 1% (See 4'1 120 34.85 Notes) T(6'-O) 0.066224 60 18'-5 28.58 1.3800 0.67 35.52 Total(Pt) Route 11 251 10'-0Y2 5.6 1 30.00 1 (See 35'-8 120 28.70 ... Route 12 Notes) Sprinkler, E(2'-O), 2T(5'-O) 12'-0 0.275552 -3.64 201 18'-5 30.00 1.0490 47'-8 13.13 201 18'-5 1% (See 4'1 120 38.20 _______ Notes) T(6'-O) 6'-0 0.072472 58 18'-S 30.00 1.3800 10,-I 0.73 38.93 Total(Pt) Route 12 ,©M.E.P.CAD, Inc. ]AutoSPRINK®1202.0.61.0 2 6110/2017 11:13:26AM Page IL? ICIuSfl.... .J%I 1%hl.40 S.?IlL1IL?Sp emote Area Number: 2 Date: 6/10/2017 09 W Actual Actual Inside Diameter 4.87 F Schedule 40 Steel Pipe Inside Diameter) ac or Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 'D egen ALV Alarm Valve AngV Angle Valve b Bushing BaIV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DeIV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11 %° Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connectk fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ik~, Inc. jAutoSPRlNK®12v12.0.61.0 2 6/10/2017 11:13:26AM Page 0 1800 2700 3601 7200 8100 4500 uu 6300 Flow - gpm 9000 Z©M.E.P.CAD, Inc. F0 AutoSPRINK®12v12.0.61.0 6110/2017 11:13:24AM Pape ) 0 60 Job Name: C3 Kids Church Remote Area Number: 2 150- 120 135 105 45 30 90 15 Water Supply Summary Sheet Node: 1 Available Static Pressure 386.46 - Supply at 123.93 124.00 ------_..14500.00 @ 117.00 286.46 386.46 83.87 with Hose Allowance at Source System demand curve_______ ....111IJJ.J.!J.LtIIIIIII 111111111 IllItlIll tltttllll liii liii 111111111 III lilt I I I I I Hydraulic Graph N 185 Date: 6/10/2017 Flexible Sprinkler Drops Unbraided Flexible Sprinkler Connection Data Sheet EASYFLEX Flexible Sprinkler Drops are designed to significantly reduce labor and installation costs. By eliminating the need for pipe culling and midline connections, you save valuable time and money. Easyflex flexible sprinkler connections offer braided and unbraided flexible hoses in 2',3',4',5', and 6' with top loading or front loading brackets for variety of ceiling and wall applications: T-Bars, metal studs, hat channels, wood beams, concrete sidewalls, and more. The system is qualified to be installed at commercial, hotel, retail, restaurants, cultural, entertainment, educational, government, healthcare, and religious buildings. EASYFLEX Flexible Sprinkler Drops Appliance Standards National Fire Protection Association (NFPA): NFPA 13: Standard fdr the Installation of Sprinkler Systems NFPA 13D : Staridard for the Installation of Sprinkler Systems in One and Two-Family Dwellings and Manufactured Homes NFPA 13R : Standard for Installation of Sprinkler Systems in residential Occupancies up to and including four stories in height NFPA 13 Section 9.2.1.3.3.3: No hangers are required for flexible connections as tong as the length does not exceed 6ft. American Soóiety for Testing and Methods (ASTM): ASTM C635 : Standard specifications for the manufacture, performance, and testing of metal suspension systems for acoustical tile and lay-in panel ceilings ASTM C636 : Standard practice for installation of metal ceiling suspension systems for acoustical tile and lay-in panels Underwriter's Laboratories, Inc. (ULIULC), cUL us 2443: Standard for flexible sprinkler hose with fittings for fire protection service International Building Code (IBC) Section 1621 /American Society of Civil Engineers (ASCE) 79.6.2.6.2 &9.6.2.6.2-2: Flexible Sprinkler Connections are an alternative solution to install without seismic escutcheons Job Name: Engineer / Architect: Job Location: Wholesaler: Submittal Date: Contractor: t.'D.2O•16O1 WEST OFFICE Toll Free (888) 577-8999 • info©easyflexusa.com EAST OFFICE Toll Free (855) 388-2600 • info@easyflexeast.com EHNICAL SPECIFrI00 11ONS UNBRAIDED FLEXIBLE HOSE SPECIFICATIONS Lengths 28 4048 60 and 67 Hose Stainless Steel 304 Outlet 1/2 or 3/4 Nut & Nipple Zinc-Plated Steel Hose Type Unbraided Sealing Gasket EPDM/ NYLON / Isolation Ring Max. Ambient 225eF Temperature Rating Max. Working 175 psig Pressure Rating * No hangers and seismic escutcheons required Required torque to assemble reducer and nipple with the flexible hose :50 ft-lb Minimum Bend Radius Connection 6" (UUULC) * DO NOT bend within 2.52 inches from connection nuts Inlet 1'NPT Outlet 1/2"or3/4NPT C@US FRICTION LOSS DATA LISTED EFU Series Unbraided Hose EX6276 TBS-PA Bracket Systems Length (in.) utlet K-Factor Max. Number of 90'Bends Equivalent Length of 1 In. I °:° n Schedule 40* Pipe, ft. 5.6 18 3/4" 8.0 3 83 UL: 6" minimum bend radius, where C=120 MD.2:) 1601 WEST OFFICE Toll Free (888) 577-8999 • info@easyflexusa.com EAST OFFICE Toll Free (855) 388-2600 • info@easyflexeast.com MODEL 475DAV T I ____A ____ 2JRN 47 /4741AV wffLK#Ns Reduced Pressure Detector Assembly Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. The Model 4750A/475DAV shall provide protection where a po- tential health hazard exists. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance ASSE® Listed 1047 (4" thru 8") AWWA Compliant C550 UL® Classified (4" thru 10") C-UL® Classified (4" thru 10") FM® Approved (4" thru 8") NYC MEA 170-02-M VOL 2 (4-8") Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (4" thru 8") NSF® Listed-Standard 61, Annex G* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) Materials Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM, NSF Listed Springs Stainless steel, 300 series Features Sizes: 4", 6", 8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 Class 125 Relief Valve discharge port: 2 1/2" - 6" - 2.75 sq. in. 8" - 10" - 3.69 sq. in. (NSFtt ,I Options (Suffixes can be combined) E) - with OS & Y gate valves (standard) D L - less shut-off valves (grooved body connections) El LM - less water meter E] - with remote reading meter - with gpm meter (standard) El - with cu ft/min meter LI V - vertical flow up configuration O G - with groove end gate valves El FG - with flanged inlet gate connection and grooved outlet gate connection O MS - with integral relief valve monitor switch BGVIC - with grooved end butterfly valves with integral supervisory switches E] P1 - with post indicator gate valve Accessories E] Air gap (see spec sheet BF-AG) 0 Repair kit (rubber only) E] Thermal expansion tank (Model XT) O Valve setter (Model FLS or MJS0rMJFS) E] Gate valve tamper switch (OSY-40) El QT-SET Quick Test Fitting Set Dimensions & Weights (do not include pkg.) DIMENSIONS (approximate) WEIGHT MODEL 475DA & B B B c C c LESS OS&Y WITH 475DAV A WITH GATE WITH BFLY LESS GATE OS&Y OS&Y WITH BFLY 0 GATE GATE BFLY SIZE VALVES VALVES VALVES OPEN CLOSED VALVES VALVES VALVES in. mm in. I mm in. I mm in. mm in. I mm in_jim in. mm in. I mm lbs. I kg lbs. kg lbs. I kg" 4" 4750A 1 185/16 465 30 762 27314 705 21 533 223/4 578 181/4 464 91/2 241 8 203 113 51.3 303 iTi 151 68.5 187/8 479 361/2 927 32 813 181/2 470 223/4 578 18114 464 91/2 241 8 203 113 51.3 303 151 1811/16 351/2 902 321/8 816 25 635 301/8 68.5 50A 765 233/4 6u3 101/2 267 10 254 187 84.9 487 221 243 110.2 50AV 21 533 42 1067 351/4 895 21 533 301/8 765 233/4 603 101/2 267 10 254 187 84.9 487 i 110.2 p 4"475DAV 50A 29 77 1168 429/16 1081 347/16 875 373/4 959 291/4 743 13 330 13 330 421 191.1 897 4Wä 246.3 50AV 305/16 770 531/2 1359 469/16 1183 305/16 770 373/4 959 291/4 743 13 330 13 330 421 191.1 897 29 737 471/2 1207 447/16 1129 34 7/16 875 406.8 75DA 453/4 1162 353/8 899 135/16 338 13 330 439 199.3 1113 042 625 283.5 50AV 305/16 770 56 1/2 1435.50 5/16 1278 305/161770 453/4 1162 353/8 89 35/16 338 13 330 439 199.3 1112 '504.t' 625 283.5 Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Rev. C Date: 12113 Document No. BF-475DA&V Patent No. 5,913,331 Product No. Model 475DA & 475DAV www.zur.c©m I Page 1 of 2 Flow Characteristics 0.0 I Rated Flow (cstablishcd by approval agcncics) (UL curve) MODEL 4750A & 475DAV 4" & 6" (STANDARD & MET IC) FLOW RATES (us) 25.2 50.5 75.7 100.9 0 U) 0. U) U) 0 -J W U) U) W a. 0 400 800 1200 FLOW RATES (GPM) MODEL 475DA & 475DAV 8" & 10" (STANDARD & METRIC) 0.0 63.1 FLOW RATES (us) 126.2 (0.... 20 15 10 5 0 138 S 0. 103 0 -j 69 w Ix U) 34 U) W 0. 1600 189.3 — 138 a —I X C,) 10., C,) 0 1000 2000 3000 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 MODEL SIZE in. mm DIMENSIONS (approximate) Al SETTER END TO END FLS in. mm Al SETTER END TO END MJS in. mm 4 100 315/161 795 295/16 745 6 150 34 3/4 884 323/4 832 8 200 47 1194 445/8 1133 10 250 51 1295 47 1194 WI. VERTICAL INSTALLATION OUTDOOR INSTALLATION Specifications The Reduced Pressure Detector Assembly shall be ASSE® Listed 1047, and supplied with full port OS & Y gate valves. The main body and access covers shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter. The Reduced Pressure Detector Assembly shall be a ZURN WILKINS Model 475DA or 475DAV. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Rabies, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zssrn.com Page 2 of 2 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: C-3 Childrens' Church SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 2708 Gateway Road CITY: Carlsbad PHONE: ( 619) 266.6030 (Industrial Fire Sprinkler Company) FAX NUMBER: (619) 266.6035 Largest Building (ft.2): Sprinkled? Construction Type:_________________ SECTION B: TO BE COMPLETED BY CONSULTANT. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): north of Gateway Road east of El Fuerte TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 124 PSI Hydrant Number (if applicable):H62100 Elevation of test: 413 Feet QalWi J. Pitot Tube,-. eading PSI Correspbnding Total Flow: 4,500 GPM Residual Pressure 117 PSI Atpeakdemand this water system is capable of providing a fire flow discharge @ 20 psi in excess of 8,000 GPM. However, this exceeds the District's 10 fps maximum velocity criteria. Therefore, the maximum allowable fire flow is 4,500 gpm. 1 Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: Name: Jennifer R. Mae[, P.E. Eng. Lic. No. (if applicable): C69606 Signature: 61 Title/Org: Pt Manager Date: 05/17/2017 I QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL QUICKESPONSE A U TOMA TI C SPRINKLERS CL SERIES UPRIGHT ° PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable stan- dards. It offers the additional feature of greatly increased safe- ty to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is ab- sorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings -. 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze ° Deflector - brass ° Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy Seal - teflon Bulb - glass with alcohol based solution, 3mm size °SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AS AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 5C ORANGE/RED INTERMEDIATE HIGH ars ono YELLOW/GREEN 200 fr , CJCt BLUE APR 2017 GFS-100a (Formerly A-20) 4 QUICK RESPONSE A U TOMA TI C SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE i LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4' (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome White Polyester3 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4' (5.7cm) Black Polyester23 8.0 (115 metric) 3/4"NPT (20mm) 2 7/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 29/16". 2FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD' cULus FM LPC CE NYC-DOB MEAIOI-92-E 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) GL2815 2.8 LH X X X X X X -- - - X GL4215 4.2 LH X X X X X X --- - - X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 8.0* LH/OH X X X X X X -- - - X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH - X X X X X X -- - -- X GL4201 4.2 LH X X X X X X -- - -- X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8I0I 8.0* LH/OH X X X X X X -- - - X GL8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X - SIDEWALLt GL8133 8.0 LH X X X X X X -- -- - -- GL2826 2.8 LH X X X X X X --- - -- X HORIZONTAL GL4226 4.2 LH X X X X X X --- - -- X SIDEWALL GL5626 5.6 LH/OH X X X X X X X - - X GL5627' 5.6 LH/OH X X X X X -- -- X X - GL8127 8.0 LH/OH X X X X X X -- --- - CONVENTIONAL GL5624 j 5.6 LH/OH X X X X X -- --- X X j X - (OLD STYLE) GL8125 1 8.0 LH/OH X j X j X j X I X -- -- X -- 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4 TO 12° BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. INSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. fPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. fUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD *1/2"NPT ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured ° Quantity ° Model Number • Style Orifice products found to be defective in material or workmanship fora ° Thread Size • Temperature ° Finishes desired period of one year from date of shipment. ° Quantity - Wrenches - P/N 325390 (1I2") For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). Wma GL613z. FIRE SPRINKLER CORPORATION APR 2017 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989.846-4583 FAX 989.846-9231 1-800-248-0278 www.globesprinkIer.com PRINTED U.S.A. GFS-1 00a (Formerly A-20) Special Note: The purlin lip is not capable of supporting NFPA 13 fire sprinkler pipe at 1(wt.) +250 lbs mm. When purlin manufacturers specify 200 lbs. max. P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 551 REVOLVER Im SIZE - ROD: 3/8" SIZE - SYSTEM PIPE: 4" max. MATERIAL - Carbon Steel or S.S. (Type 304). 1 3/8 1.250 t 00 W9 in /1'IØ 12.0312 FINISH - Mu. Galvanized. LISTING/APPROVAL - c(20"203 - EX 2551 PATENT - No. 6,568,642 FUNCTION - Attachment component of an AFCON hanger. To support horizontal piping. INSTALLATION - Per NFPA 13 and these instructions. Install on vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawing. Center mounting hole accepts 3/8" and 1/2" fasteners. SPECIAL c®us FASTENERS PER NFPA 13- See table. FEATURES * Universal fastener array for enhanced mounting. * Hangs plumb from one fastener. * Radius -Tapped Rod Bore: Improves thread engagement and eliminates structural deficiencies associated with rod inserts. * No backing nuts required. ORDERING - Part # and finish. I STEEL PIPE MOUNTING FASTENERS I Steel - #14 SMS or #14 Tek Steel - #io mis or #905 'Wood Pipe Qty. Mm. Qty. Pipe Mm. Qty. Pipe Size Thickness Size Thickness Size 1/4 x I /2 LS I 2 14 GA. 1 3 18 GA. 1 2 Yz 24 24 2 3 #14 x I /2 SMS I 2 16 GA. 1 2 Y2 3 4 2 4 2 4 20 GA. 2 3 #I6x2DS 2 2 18 GA. I 2'/2 4 4 3 4 2 3 22 GA. 3 3 Wood - Thru 5/8" Gyp 3 4 114x2 LB I 2 20 GA. 2 *1 2 4 * @BONLY 2 3 SMS Sheet Nicol Screw DS- Drive Screw #14x2SMS I 2 3 4 LS-La5Screw 22 GA. 3 2 V2 Gyp= GypsttmBoard 2 4 TckTck Screw Fastener Locations I l© BorE 3@ A-C-C ® ® 2@ B.0 3@ 8.0-F ® 2© A-C 4@ A-C.0.F 11/15 S Features & Benefits Solid, one-piece, cold formed and machined anchor Entire system requires only one driver *self-dril ling (except for self-tapping threads point HangerMate LG for steel applications anchors) Heads precision drilled and gimlet point tapped to twin-lead threads with slot accept 3/8-16 for wood applications or 1/4-20 threaded components gimlet point EZE270 twin-lead threads adapter allows for concrete applications installation of 1/2-13 threaded rod !!!!!k_ self-drilling components special threads point LG style allows MP style for steel, wood installation of or concrete applications threaded rod systems into light-gage metals MP style can be used in metal, wood or concrete, reducing the number of parts that need to be stocked Different thread and point styles available to meet the requirements of specific application materials Special hex nuts supplied as required Many styles UL listed and/or FM approved (see table inside) Ease assembly of HVAC, fire sprinkler, refrigeration, piping, and electrical systems for ceiling- or wall-mounted applications HANGEAA&ze, Threaded Rod Anchoring System HangerMate® anchors were designed to speed installation of fire sprinkler, HVAC, refrigeration, general piping, and electrical systems. They can also be used to install strut channels, cable trays, suspended ceiling grids, bridle rings and eye-rods. HangerMate anchors can replace beam clamps, powder-actuated stud pins, eye sockets, or ceiling flanges, and eliminate labor-intensive operations such as pre-punching or drilling of steel components. Power of One The entire system has been re-engineered so only one driver is needed for all anchor sizes (except HangerMate LG anchors), regardless of the substrate material. Preparing concrete applications is accomplished with a standard 1/4" drill bit. Head Styles Two head styles are available: HangerMate vertical-mount anchors feature a tapped head end-drilled to permit in-line mounting of head threaded rod systems HangerMate side-mount anchors feature a cross-drilled and tapped head to permit side-mounting of threaded rod systems cross-drilled head Both head styles feature a wide array of thread and point styles for use in steel, concrete, masonry or wood applications, including the MP style that can be used in all three materials. Many styles are Factory Mutual (FM) approved or Underwriters Lab (UL) listed (see following pages). Find out just how versatile and beneficial the HangerMate anchoring system can be. rj Elco Construction Products ELCO . 1301 Kerr Drive • Decorah, IA 52101 1.800.435.7213 Fax: 563.387.3540 www.elcoconstruction.com 0 HangerMate® Tlided Rod Anchoring System Steel Applications* Vertical Mount - End-Drilled Head 1/4-20 .060 -250 .250 I ..j EZG 160 1/4-20X1 #3 point N/A N/A N/A N/A 3/8-16 .060 -125 .125 EZG450 1/4-20X1 #2 point 4" 0.125' 3/8-16 .060 -250 .250 EZG470 1/4-20X1 #3 point 4" 0.125" 40 12 ga. 3/8-16 .060 -250 .250 EZG471 1/4-20X1 #3 point w/nuts 4" 0.060" 40 16 ga. 3/8-16 .060 -250 .250 EZG490 1/4-20X1-1/2 #3 point 4" 0.125" 40 12 ga. 3/8-16 .060 -250 .250 EZG491 1/4-20X1-1/2 #3 point w/nuts 4" 0.060" 40 16 ga. - 3/8-16 .060 -250 .250 EZG530 1/4-20X2 #3 point 4" 0.125" 3/8-16 .060 -250 .250 EZG540 1/4-20X3 #3 point 3/8-16 .187 -500 .500 EZG510 1/4-20X1-1/2 #5 point 4" 0.125" 4' 0.125" 3/8-16 .060 060 -500 EZG511 1/4-20X1-1/2 #5 point w/nuts 4" 0.060" 40 16 ga. t 1/4-20 26 ga. -.187" EZG610 1/4-20 collapsing insert N/A N/A N/A N/A CM 3/8-16 26 ga. -.187" EZG580 1/4-20X1; use with EZG610 2.5" 22 ga. 4° 12 ga. 3/8-16 26 ga. -.187" EZG590 1/4-20X1; use with EZG610 3.5" 18 ga. 4" 12 ga. 3/8-16 26 ga. -.187° EZG600 1/4-20X1; use with EZG610 4" 16 ga. 4" 12 ga. Horizontal Mount - Cross-Drilled Head 1/4-20 .060 -250 .250 EZH 155 1/4-20X1 #3 point iii N/A ••---i N/A N/A - 0 N/A 3/8-16 .060 -125 .125 EZH455 1/4-20X1 #2 point 3/8-16 .060 -250 .250 EZH475 1/4-20X1 #3 point 3/8-16 .060 -250 .250 EZH476 1/4-20X1 #3 point w/nuts 4° 0.060" 4° 16 ga. 3/8-16 .060 -250 .250 EZH495 1/4-20X1-1/2 #3 point 3/8-16 .060 -250 .250 EZH496 1/4-20X1-1/2 #3 point w/nuts 4" 0.060" 4° 16 ga. 3/8-16 .187 -500 .500 EZH515 1/4-20X1-1/2 #5 point 3/8-16 .060 -500 .500 EZH516 1/4-20X1-1/2 #5 point w/nuts 4" 0.060" 40 16 ga. 3/8-16 .060 -250 .250 EZH535 1/4-20X2 #3 point NOTE: It is the responsibility of the installer to determine the application-specific details under which a code approval or listing was granted. Contact Elco Construction Products for more information. tCollapsing insert EZG610 can be used alone to install 1/4-20 threaded components or with EZG580, EZG590 or EZG600 hangers to install 3/8-16 threaded components. *Installation in Steel or Wood Applications: Use EZE215 drive socket (see next page). Hex drive will automatically disengage when anchor is seated. 0 HangerMate*readed Rod Anchoring System Wood Annhications* Vertical Mount - End-Drilled Head 1/4-20 EZG315 5/16X2-1/4 NA NA 3/8-16 EZG650 5/16X2-1/4 4" 4" 3/8-16 EZG670 5/16X3 4" 4" Horizontal Mount - Cross-Drilled Head — Rod Size -ElcoI.rNo. 'I1fPi)i II!PipeI1: th'ilPipefTft: 1/4-20 EZH320 5/16X2-1/4 NA NA 3/8-16 EZH665 5/16X2-1/4 3-1/2° Concrete Applications* * Vertical Mount - End-Drilled Head T? ii. • 1/4-20 EZG365 5/16X2-1/4 NA NA 3/8-16 EZG73O 5/16X2-1/4 4' Horizontal Mount - Cross-Drilled Head 1/4-20 EZH370 5/16X2-1/4 NA NA 3/8-16 EZH735 5/16X2-1/4 40 Steel, Wood or Concrete Vertical Mount - End-Drilled Head 1/4-20 EZG910 1/4-10X2 NA NA 3/8-16 EZG930 1/4-10X2 Horizontal Mount - Cross-Drilled Head 3/8-16 EZH935 1/4-10X2 NA NA All Materials - Adapter for Hanging 1/2" Rodt 1/2-13 EZE270 NA NA Simply install any 3/8" HangerMate anchor as required, then thread EZE270 adapter into it. Use of adapter does not increase performance value of 3/8° HangerMate anchor. Check corresponding 3/8" anchor spec sheet for load-carrying capacity and add appropriate safety factor. Installation Tools EZE215 Drive Socket ____ EZE220 Drive Sleeve EZE240 Drill Bit Adapter c:c:1J5 EZE320 25/64 Drill Bit with Stop Collar EZE34O ANSI 1/4" Tanged Drill Bit for _Hammer _Drills ANSI 1/4'SDS EZE350 Drill Bit for Rotary Hammer Drills NOTE: It is the responsibility of the installer to determine the application-specific details under which a code approval or listing was granted. Contact Elco Construction Products for more information. EZE36O 7/32" Tanged Drill Bit for Hammer Drills EZE380 7/32' SDS Drill Bit for Rotary Hammer Drills Tool for EZG580/ EZE290 EZG590/EZG600/ lz_~± EZG610 components ELY100 Drill Bit Adapter for 7/32" drill bit ** Installation into Concrete/Masonry Applications Insert tanged bit (EZE340) in bit holder (EZE240), or use SOS bit (EZE350). Drill hole, then slide concrete drive socket (EZE220) over bit and onto hex. Insert anchor into socket and install. Parts can also be installed in concrete using standard 1/4" masonry bit to drill hole and use EZE215 drive socket to set anchor. Steel Applications S Average Ultimate Value (lbs)* End-Drilled Anchors EZG160 114-20 I 1,14-20 786 1139 1738 2376 4694 5994 EZG450 3/8-161 1/4-20 922 1351 2273 2488 N/A N/A .EZG470 3/8-161 1/4-20 786' 1139 1738 2376 4694 5994 EZG471 3/8-161 1/4-20 3435 4024 4279 4692 5812 5909 EZG490 3/8-16 1/4-20 786 1.139 1738 2376 4694 5994 EZG491 3/8-16 1/4-20 3435 4024 4279 4692 5812 5909 EZG510 8-1611/4-20 N/A. N/A N/A N/A : 3677 5207 EZG511 8-1611/4-20 3435 4024 4219 4692 5812 5909 EZG530 8-1611/4-20 .786 1139 1738 2376 4694 5994' EZG540 3/8-16 1/4-20 786 1139 1738 2376 4694 5994 Cross-Drilled i Anchors 1?I flf:4iI- 1- EZH155 1/4-2011/4-20 1739 1944 2420 2570 2809 2809 EZH455 3/8-16 1/4-20 1860 2071 2516 2606 N/A EZH475 3/8-16 1/4-20 1739 1944 2420 2570 2809 2809 EZH476 3/8-16 1/4-20 2756 2753 2809 2809 2809 2809 EZH495 3/8-16 1/4-20 1739 1944 2420 2570 2809 2809 EZH496 3/8-16 1/4-20, 2756 2753 2809 2809 2809 2809 EZH515 3/8-1611/4-20 N/A N/A N/A N/A 3529 3529 EZH516 3/8-16 1/4-20 2756 2753 2809 2809 2809 2809 EZH535 3/8-161 1/4-20 2756 2753 2809 2809 2809 2809 Product and Warranty Information Code listings and approvals require that HangerMate- anchors be installed with HangerMate drive sockets. Shoulders of installed HangerMate anchors must be flush to the metal, masonry or wood substrate materials. HangerMate anchors should not be subjected to vibratory or shock loads resulting from such applications as anchorings for reciprocating machinery, crane rails or hoists. Care should be taken to not damage HangerMate anchors or the substrate into which they are installed when loading pipe, installing cable tray, or otherwise suspending components from HangerMate anchors. Failure to do so may result in significant loss of holding power. As with all cutting tools and fasteners, normal safety precautions should be observed to avoid electrical installations, other utilities and reinforcement bars; careful use will provide the utmost safety and reliability. The wearing of safety glasses by users and persons in the vicinity is required by Federal Law. This literature was prepared as an introductory summary of the HangerMate threaded rod anchoring system from Elco Construction Products and is not, therefore, intended to describe all hazards, limitations, warnings, precautions, etc. pertaining to the use of the product. The information and data presented herein are believed to be accurate and reliable, however, due to the wide variety of possible intervening factors, the suitability of the product for the use intended is the sole responsibility of the user. Specifications and other information contained herein supersede all previously published material and are subject to change without notice. All HangerMate anchors are warranted to be manufactured free from defects in material and workmanship. Under this warranty, Elco Construction Products will provide, at no charge, replacement product for any HangerMate anchors proven to be defective when installed in accordance with our published recommendations and in applications considered by us as suitable for this product. This warranty is in lieu of any and all warranties, expressed or implied, and in no case will Elco Construction Products be liable for incidental, liquidated or consequential damages. Light-gage Steel App tions ejsJ Max. Pipe Diameter 2.5' 350 4- Min. Steel Thickness 22 ga. 18 ga 16 ga Ultimate Tensile Load' Gage 26 1 22 1 20 1 18 16 Ultimate Tensile Load 1 848 1 1025 1 1153 1 1410 1880 Wood Applications Average Ultimate Value (lbs)* End-Drilled Anchors EZG315. 1/4-20 1 5/16-14 1 2487 1 2162 1, 1768 EZG650 3/8-16 5/16-14 2487 2162 1768 EZG670 3/8-16 5/16-14 2487 2162 1 1768 Cross-Drilled Anchors EZH320 ' 1/4-20 5/16-14 ' 1801 1460 1451 EZH665 3/8-16 5/16-14 1801 1460 1451 Concrete Applications Average Ultimate Value (lbs)* End-Drilled Anchors EZG365 1 1/4-20 1 5/16-14 1 2188 EZG730 1 3/8-16 5/16-14 1 2188 Cross-Drilled Anchors EZH370 1 1/4-20 5/16-14 2767 EZH735 1. 3/8-16 5/16-14 2767 HangerMatee MP Anchors - End-drilled Product Only Average Ultimate Value (lbs) Application Material Performance Values: End-drilled Product Only Southern Pine 1541 16 ga steel 880 14 ga steel 1106 12 ga. steel 1754 1/8" steel 2505 Concrete (3300 psi) 2933 * Performance Testing Notes: The loads indicated are average ultimate values achieved under laboratory conditions and appropriate safety factors should be applied for design purposes. NFPA (National Fire Protection Assoc.) minimum fastening requirements are five times the weight of a 15 foot section of water filled pipe plus 250 lbs. This is 1475 lbs. for 4" pipe. All test values were obtained using 3/8-16 rod. When 1/4-20 rod is used, the strength of the rod may be less than the pull-out values of the anchors. Loads were determined by testing products in the orientation for which they were designed to be used. End-drilled parts were pulled in line with the anchor's axis while cross-drilled parts were tested with the force perpendicular to the axis. Elco Construction Products 1.800.435.7213 0 fax: 563.387.3540 www.elcoconstruction.com m tnas . Avdei iFonn HangerMate, iForm and Infastech are registered trademarks of Infastech Intellectual Properties Pte Ltd. AvdelO is a registered trademark of Avdel UK Ltd. ©2011 Infastech Intellectual Properties Pte Ltd. All rights reserved. NFPAI3 PIPE ROD 1 W 5W1.+250 UL TEST LOAD 1 3/8 30.75 403.75 750 1114 3/8 43.95 469.75 750 11/2 318 54.15 520.75 750 2 3/8 1 76.95 634.75 1 750 21/2 3/8 118.35 641.75 1 850 3 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 2650 8 1 1/2 1 711.00 3805.00 4050 I thru 4 Inch pipe LISTED FOR STEELICPVC 1/2 & 3/4 Inch pipe 5 thru 8 Inch pipe P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER SIZE - ROD- 3/8' or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel. FINISH - Mu. Galvanized to G-90 specification. LISTING/APPROVAL - tam 203-EX 25511"- 8" .62 Approval guide - 1"- 8" OSIIPD OPA-0601 See Website. Conforms to Federal Specification WW-H- 171 E type 10, and Manufacturers Standardization Society SP-69, type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe component of an AFCON hanger. To support horizontal steel, CPVC or copper pipe. INSTALLATION - Per these instructions including NFPA 13 and the CPVC manufacturers instructions. FEATURES * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 9/15 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON#300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger: To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. 51 V Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER- AFCON will NOT warrant against the failure of its products when used in combination with other products, pans or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non.AFCO,V products have been, or are used. 1/08 Can be installed on bar joists or 1-beams Thumb spring retainer allows for ease of positioning Snap-off bolt head helps enable easy installation and inspection of seismic sway braces No assembly required No loose parts Meets NFPA®-13 requirements for seismic sway bracing Material: Steel Finish: Electrogalvanized c®us <is> OSHPD APPROVED Jrul t5$1 f * , M CSBBARJEG 1/4" - 1/2 2" 3" w_ Parallel - 10 3.000 tb ,I,' t1 1' iPerpndictiLar 1 1 12 3 40 Lb NINE 3Oaw— ç Amm as Parallel N/A 1.410 lb 2.110 lb 2.540 Lb 2.830 lb PeIpendicula v J N/A 1 740 lb . i7lO Lb :Z0 2300 Lb FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL. UR, cUL. cUR, cULus and cURus are registered certification marks of UL LLc. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. - © 2017 Pentair All rights reserved Pentair. CADDY. CADWELD, CRITEC, ERICO, ERIFLEX. ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. ___ +PENTAIR Universal design allows one product to attach directly to concrete, wood, bar joist or I-beam adapters Snap-off bolt head helps enable easyinstallation and inspection of seismic sway braces Use for both lateral and longitudinal sway brace applications Works with 1' through 2' brace pipes and 1/4" angle iron braces to-reduce' inventory Center bolt does not require tightening Meets NFPA®-13 requirements for seismic sway bracing —14- Material: Steel Finish: Electrogalvanized c®us <8> OSHPD APPROVED U A' Par'AINumbeI 1 ) Wc-?'t F4 r X: 114ZAI — Mal CSBUN 9/6 / 4 / CSBUN 0 1316 5/ 14 &. npf MAR i'al"MURM 11 -MON. Pipe 1" :10' 3,000 Lb - 1/4 Thick~A!jgi w1 ..,8 20151b atl It pe il W1,111"I'M lamnamp M s oJ T Pipe N/A 1,620 lb 2,300 Lb 2,820 lb 3,140 Lb FM is a registered certification mark of FM Approvals LLc. LTD. NFPA is a registered trademark of National Fire Protection Association. Inc. UL. UR, cUL. cUR, cULus and cURus are registered certification marks of UL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2017 Pentair ALL rights reserved Pentair, CADDY. CADWELD, CRITEC, ERICO. ERIFLEX, ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. ___ +PENTAIR Use for both lateral and longitudinal sway brace applications Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1" through 2" brace pipes and 1/4 angle iron braces to reduce inventory Slotted design grabs service pipe for added gripping strength Meets NFPA0-13 requirements for seismic sway bracing Material: Steel Finish: ElectrogaLvanized c®s <a> OSHPD APPROVED Part Number Pipe Size A B CSBSTU0100EG 1" 67/8' 1" CSBSTUO125EG 1 1/4 73/8" 1" CSBSTUOI50EG 1 1/2' 73/4 CSBSTU0200EG 2' 81/8" 13/16" CSBSTU0250EG 2 1/2' 8 7/8' 13/16" CSBSTU0300EG 93/8" 13/16" CSBSTU0400EG 10 5/8' 1 1/2' CSBSTUO500EG 12 1/8' 1 1/2" CSBSTU0600EG 135/8" 2" CSBSTUO800EG 8" 15 3/4" 2" CSBSTU1000EG 10" 18' 2' UL Loads (Listed for Restraints) Part Number ' Dyna-Flow® Service Pipe Sch 10 Service Pipe Sch 40 Service Pipe CSBSTU0100xx N/A 655 lb 655 lb CSBSTU0125xx 655 Lb 655 lb 655 lb CSBSTU0150xx 655 Lb 655 lb 655 lb ___ 4PENTAIR io F®i COT rcePipe jSeeP ePqe' SercePpe Sercep ercePip ServePpe ServicePip CSBSTU0200xx 3,000 Lb N/A 3.000 Lb 3.000 Lb N/A - N/A N/A N/A SBS CT1J0250xx' :3.000 iby' NW,k S'3 000 lb' 3.00O.Lbf Lb ' .2.015 N/A!D, " : 2O•1 Lb' ,. .,. CSBSTU0300xx 3.000 Lb N/A 3.000 lb 3.000 Lb .2.015 lb N/A 2.015 Lb 2.015 Lb CSBSTU0400X 3.000lb't 900.L? 'L 3,000 t .,3.00Ptb7i '2.015Lb'2.015 Lb) CSBSTU0500xx N/A 3.000 Lb 3.000 lb 3.000 lb N/A N/A 2,015 lb 2.015 lb CSBSTUO6O0xx N/A L 000 Lb 3000 lb 3 000 lb ' N/A 2015 lb ', 2015 lb I , 2 015 lb ,.. CSBSTU0800xx N/A N/A 3,000 lb 3.000 lb N/A N/A 2.015 lb 2.015 Lb -CSBSTU1O00x N/Ai $N/A ' 3.000li 3.000lb' /A: 'V' lb.• :;., , Part __ Vi J All 594 60j o$ 044 607 f 96 CSBSTUO100xx 860 lb 1.220 lb 1.500 lb 1.670 lb 970 lb 720 Lb 860 Lb 960 lb CS8STU0125xx 860 lb 1 220 Lb ',,1 500 Lb t 1 670 lb 970 lbt, k 720 Lb ' 860 lb "'c "-' 960 (V CSBSTU0150xx 860 lb 1,220 lb 1.500 Lb 1.670 lb 970 lb 720 lb 860 lb 960 lb ,CSBSTU02O0x" '1530 (b'' -' .2,160 ib'i' 41650 Lb .2,960Lb 870lb 690 Ib' 'L 830 tb' .''93Olb"f' CSBSTU0250xx 1.530 lb 2,160 lb 2.650 Lb .2.960 lb 870 lb 690 lb 830 Lb , 930 Lb CSBSTU0300xx 530 lb t 2,160 lb '2.650 Lb' 2 960 lb 870 lb 690 lb F , 830 lb " ,930 lb CSBSTU0400xx 1.570 lb 2.220 lb 2.720 Lb 3,030 lb 1,550 lb 1.390 lb 1,680 lb 1.870 lb csBsTuo5o0xr'..1,57oit j.2.220 Lb 2 , 2.7 3,030 ,3,030Lb ' i.390ibj '.'.*1,680lb. ."1,870ib CSBSTU0600xx 1,980 lb 2.810 lb 3,440 lb 3,840 lb 1.470 lb 1.170 lb 1.410 lb 1.570 lb ak'uJe 559 6074 75 304ç 4559 60 CSBSTU0800xx 2,040 lb 2.890 lb 3.540 lb 3.950 Lb 1.200 lb 1.700 Lb 2.090 Lb 2.330 lb 'CS8STU100Oxx, 4?.P0Lbit _ 2.890lb ",";3 5401 'F, _39j'. ?00J• _ L''\ '2,090tb'iii. ' ___2.330tb, Dyne-Flow is registered trademark of Allied Tube & Conduit Corporation. FM is a registered certification mark of FM Approvals LLC. LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL, UR, cUL. cUR, cULus and cURus are registered certification marks of UL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair Customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage. serious bodily injury and death and/or void your warranty. . . © 2017 Pentair All rights reserved - Pentair, CADDY. CADWELD. CRITEC. ERICO. ERIFLEX. ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the properly of their respective owners. Pentair reserves the right to change specifications without prior notice. LI PENTAIR The Quick Grip Lateral Brace, part of the CADDY line of fire sprinkler bracing systems from Pentair. is designed to help simplify installations when bracing service pipe for seismic or other catastrophic events. It features an innovative design for quick attachment of brace pipe to service pipe saving time and money. Easy two-step installation elminates extra trips between structure and service pipe Works with 1" and 1 1/4 (25 mm and 32 mm) brace pipes to reduce inventory Yellow tips provide a visual indicator that the bolts have been properly torqued Easy installation with an impact wrench from the bottom side of the clamp Meets NFPA®-13 requirements for seismic sway bracing Material: Steel Finish: Electrogalvanized C&U, OSHPD APPROVED Part Number Pipe Size Height Width H W CSBQG0250EG 2 1/2 5 7/16 -57/8 63/4" CSBQG0300EC 3" 6 1/8 - 6 1/2 7 1/2 CSBQG0400EG 4" 7 1/8" - 7 1/2" 8 3/4" CSBQG0600EG 6" 9 1/4 -95/8 113/4" CSB060800EG 8' 113/8 -11 13/16' 137/8" UL Loads Part Number Service Pipe Schedule LateraL 1" Brace Pipe 1 1/4' Brace Pipe CSB000250EG Dyna-Ftow® 2,015 Lb 2.015 Lb 10 2,015 Lb 2.015 Lb 40 2.015 lb 2.015 lb CSBQG0300EG Dyna-Flow® 2.015 Lb 2.015 Lb 10 2.015 Lb 2.015 Lb 40 2.015 tb 2,015 lb CSB000400EG Dyna-Flow® 2,015 lb 2.015 Lb 10 2.015 Lb 2,015 lb 40 2.015 lb 2,015 lb +PENTAIR jP& A AL UL Loads NW Part Number Service Pipe Schedule Lateral 1'. Brace Pipe 1 1/4 Brace Pipe CSBQG0600EG Mega-Flow 2,015 lb 2.015 lb 10 2,015 Lb 2,015 lb 40 2.015 Lb 2,015 lb CSBQG0800EG 10 2.0151b 2.015 lb 40 2.015 lb 2.015 Lb FM Loads Part Number Service Pipe Schedule Lateral Horizontal Capacity per Installation Angle From Vertical 30o - 440 45° - 59° 60° - 74° 75° - 90° CSBQG0250EG Lightwall 1.410 lb 2.000 lb 2.450 lb 2.740 Lb 10 1.410 lb 2,000 lb 2.450 lb 2.740 lb 40 1.410 lb 2,000 lb 2,450 Lb 2.740 lb Lightwall 1.190 Lb 1,680 lb 2.060 lb 2.300 lb CSB000300EG 10 1.190 Lb 1,680 lb 2.060 lb 2.300 lb 40 1,190 Lb 1,680 lb 2.060 lb 2.300 lb CSBQG0400EG Lightwall 1.190 lb 1.680 lb 2,060 lb 2.300 lb 10 1,190 lb 1,680 lb 2.060 lb 2.300 lb 60 1,190 lb 1,680 lb 2,060 lb 2.300 lb CSBQG0600EG LightwalL 870 lb 1.230 lb 1.510 lb 1.690 lb 10 8701b 1.230 lb 1,510 lb 1.690 lb 40 970 lb 1,370 lb 1.680 lb 1.870 lb CSBOGOBOOEG 0.188"(Wait Thickness) 790 Lb 1,110 lb 1.360 lb 1,520 lb 40 790 lb 1,110 lb 1.360 lb 1.520 lb Dyna-Flow is a registered trademark of Allied Tube & Conduit Corporation. FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is registered trademark of National Fire Protection Association, Inc. UL. UR. cUL, cUR, cULus and cURus are registered certification marks of UL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentairs product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2017 Pentair Alt rights reserved Pentair, CADDY. CADWELD, CRITEC, ERICO, ERIFLEX. ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. ___ +PENTAIR Flexible Coupling PfC Ughi-duty Flexible Coupling t AV. 4D.. FMI10- 0Fu-rvlech 0 MECH. I MME CASTING LC1 y- 25 33.7 500 55 92 42 3/8X55- 2 UL FM 1 1.321 3.45 2.16 3.62 1.65 VdS LPCB 32 42.4 500 65 104 44 UL FM 1A 1.669 3.45 256 4.14 1.74 3/8X55-2 VdS LPCB 40 48.3 500 70 110 44 3/8X55-2 UL FM 1~ 1.900 3.45 2.15 4.33 1.74 VdS LPCB 50 60.3 500 83 124 44 YL FM 2 2.375 3.45 3.27 4.88 1.74 318X55- 2 VdS LPCB 65 73.0 500 96 1 45 - 43 318X55-2 UL FM 2½ 2.875 3.45 3.78 5.63 1.78 LPCB 65 76.1 500 100 145 45 318X552 UL FM 2~ 3.000 3.45 3.94 5.71 1.78 - VdS LPCB 80 88.9 500 115 160 45 112X702 UL FM 3 3.500 3.45 4.53 6.30 1.18 VdS LPCB 100 108.0 500 138 190 50 112X702 UL FM 4 4.250 3.45 5.43 7.48 1.97 - LPCB 100 114.3 500 145 198 50 112X10- 2 UL FM 4 4.500 3.45 5.11 1.80 1.97 VdS LPCB 125 133 450 162 225 51.0 518X80-2 UL FM 5 5.250 3.10 6.38 8.86 2.01 LPCB 125 139.7 450 169 230 52 518X802 UL FM 5 5.500 3.10 6.65 9.06 2.05 VdS LPCB 125 141.3 450 170 232 51 518X802 UL FM 5 5.563 3.10 6.69 9.13 2.01 LPCB 150 159.0 450 190 254 52 518X85- 2 UL FM 6 6.250 3.10 7.48 10.00 2.05 . LPCB 150 165.1 450 196 260 52 518X85 2 UL FM 6 6.500 3.10 7.72 10.24 2.05 LPCB 150 168.3 450 200 265 52 5/8X85-2 UL FM 6 6.625 3.10 7.87 10.43 2.05 VdS LPCB 200 219.1 450 258 350 60 314X115 2 UL FM 8 8.625 3.10 10.24 13.78 2.37 VdS LPCB 250 273.0 300 337 406 65 718X140 2 UL FM 10 1 10.150 2.07 13.27 16.00 2.56 VdS 300 323.9 300 372 460 64 718x140-2 UL FM 12 12.750 2.07 14.65 18.11 2.52 350 317.0 225 428 520 72 718X140 3 UL FM 14 14.842 1.6 16.85 20.45 2.85 400 426.0 225 476 570 73 8 140-3 UL F 16 16.772 1.6 18.74 22.45 2.87 . ' cj :--V, 125 139.7 450 168 228 51 518X80-2 U I F M 5 5.500 3.10 6.61 898 2.01 165 168.3 450 200 265 52 51BX85 2 UL FM 6 6.625 3.10 7.87 10.43 2.05 250 273.0 300 320 395.0 64 3/0120-2 UL FM 10 10.750 2.07 12.60 15.55 2.52 NO 4_10 I 25 33.7 500 59 100 44 318X55-2 I FM 1 1.327 3.45 2.33 3.94 1.74 VdS LPCB 32 42.4 500 66 105 45 X55 UL FM 1¼ 1.669 3.45 2.60 4.13 1.78 VdS LPCB 40 48.3 500 72 112 45 318X55 UL FM 1¼ 1.900 3.45 2.84 4.41 1.78 VdS LPCB 50 60.3 500 85 130 45 /8X55- UL FM 2 2.375 3.45 3.35 5.12 1.78 VdS LPCB 65 73.0 500 98 140 45 , x UL FM 2¼ 2.875 3.45 3.86 5.52 1.78 - LPCB 65 76.1 500 101 145 45 3/8X55- UL FM 2¼ 3.000 3.45 3.98 5.71 1.77 VdS LPCB 80 88.9 500 115.0 168 46 1/2X70-2 UL FM 3 3.500 3.45 4.53 6.62 1.82 VdS LPCB 100 108.0 500 140 197 52 1/2X70-2 UL FM 4 4.250 3.45 5.51 7.76 2.05 LPCB 100 114.3 500 146 200 52 UL FM 4 4.500 3.45 5.75 7.88 2.05 1/2X70- 2 VdS LPCB 125 133 450 165 226 52 5/8X85.2 UL FM 5 5.250 3.10 6.50 8.90 2.05 LPCB 125 139.7 450 170 235 52 5! X85 UL FM 5 5.500 3.10 6.69 9.25 2.05 VdS LPCB 125 141.3 450 172 235 52 5!8X852 UL FM 5 5.563 3.10 6.77 9.25 2.05 LPCB 150 159.0 450 190 267 52 518X85- UL FM 6 6.250 3.10 7.48 10.51 2.05 LPCB 150 165.1 450 198 262 52 5/8X85-2 UL FM 6 6.500 3.10 7.80 10.32 2.05 LPCB 150 168.3 450 202.0 265 52 5!8X85- 2 UL FM 6 6.625 3.10 7.95 10.43 2.05 VdS LPCB 200 219.1 450 260.0 342 62 3/0115-2 UL FM 8 8.625 3.10 10.24 13.45 2.44 VdS LPCB 250A 267.4 300 318 396 63 310120.2 UL FM 10 10.528 2.07 12.52 15.60 2.48 250 273.0 300 327 420 63 iixs- 2 UL FM 10 10.750 2.07 12.88 16.54 2.48 LPCB 300A 318.5 300 364 456 63 7 X140 UL FM 12 12.539 2.07 14.33 17.95 2.48 300 323.9 300 370 465 63 7 8 140 UL FM 12 12.750 2.07 14.57 18.30 2.48 350 355.6 300 415 TiW 72 7/8X140-3 UL FM 14 14.000 2.07 16.34 20.08 2.84 350 377.0 225 435 535 72 7/8X140 3 FM 14 14.842 1.6 17.13 21.05 2.84 400 406.4 300 468 575 72 X1403 UL FM 16 16.000 2.07 18.43 22.64 2.84 400 426.0 225 490 592 72 7/8X140 4 FM 16 16.772 1.6 19.29 23.30 2.84 500 529.0 225 b95 70 76 7!8X140 4 20 20.827 1.6 23.43 27.56 3.00 ITrIh 1G Rigid Coupling 65 76.1 300 100 140 45 318X55-2 UL FM 2¼ 3.000 2.07 3.94 5.52 1.77 80 88.9 300 114 15 15 318X55-2 UL FM 3 3.500 2.07 4.50 6.30 1.78 100 108.0 300 135 5 1 UL FM 4 4.250 2.07 5.30 7.28 1.97 100 114.3 300 140 117 50 1/2X70-2 UL FM 4 4.500 2.07 5.51 7.36 1.97 125 139.7 300 168 225 50 1 - UL FM 5 5.500 2.07 6.62 8.86 1.97 125 141.3 300 110 225 50 1 - UL M 5 5.563 2.07 6.69 8.86 1.97 150 159.0 300 190 252 50 UL FM 6 6.250 2.07 7.48 9.92 1.97 150 165.1 300 1 - UL FM 6 6.500 2.07 7.68 _2_ J.2!_ 150 168.3 300 5 255 50 1 UL FM 6 6.625 2.07 7.87 10.04 1.97 200A 216.3 300 255 320 8 518X85-2 UI M 8 8.516 2.07 10.04 12.60 2.28 200 219.1 300 255 322 58 . U FM 8 8.625 2.07 10.05 12.68 2.28 250 273.0 300 318 410 63 3/4X120-2 UI FM 10 10.750 2.07 12.52 16.14 2.48 Light-duty Rigid Coupling OFu-Mech JECH MODE CASTING Light-duty 900 Elbow I! 50 60.3 300 70 UL FM VdS 2 2.375 2.07 2.75 65 73.0 300 76 UL FM 2½ 2.875 2.07 3.00 65 76.1 300 76 UL FM VdS 2¼ 3.000 2.07 3.00 80 88.9 300 85.5 UL FM VdS 3 3.500 2.07 3.37 100 108.0 300 101 UL FM 4 4.500 2.07 3.98 100 114.3 300 101 UIFMVdS 4 4.500 2.07 3.98 125 139.7 300 124 ULFMVdS 5 5.500 2.07 4.88 150 159.0 300 140 ULFMVdS 6 6.500 2.07 5.50 150 165.1 300 140 - UL FM 6 6.500 2.07 5.50 150 168.3 500 140 ULFMVdS 6 6.625 3.45 5.50 200 216.3 300 175 UL FM 8 8.625 2.07 6.89 200 219.1 300 165 UL FM VdS 8 8.625 2.07 6.50 psf1 MECH - Fu-Mech MEIDE CASTING 25 33:7 500 57 UL FM 1 1.315 3.45 2.24 VdS 32 42.4 500 70 UL FM 1¼ 1.660 3.45 2.75 VdS 40 48.3 500 70 UL FM 1½ 1.900 3.45 2.75 VdS 50 60.3 500 82.5 UL FM 2 2.375 3.45 3.25 VdS 65 73.0 500 95 UL FM 2¼ 2.875 3.45 3.74 65 76.1 500 95 UL FM 2¼ 3.000 3.45 3.74 VdS 80 88.9 500 108 UL FM 3 3.500 3.45 4.25 VdS 100 114.3 500 127 UL FM 4 4.500 3.45 5.00 VdS 125 133.0 500 122 UL FM 5 5.250 3.45 4.80 125 139.7 500 140 UL FM 5 5.500 3.45 5.50 VdS 125 141.3 500 140 UL FM 5 5.563 3.45 5.50 150 165.1 500 165 UL FM 6 6.500 3.45 6.50 150 168.3 500 165 UL FM 6 6.625 3.45 6.50 VdS 200 219.1 500 197 UL FM 8 1 8.625 3.45 7.75 VdS 250 267.4 500 229 UL FM 10 10.528 3.45 9.00 250 273.0 500 229 UL FM 10 10.750 3.45 9.00 VdS 300 318.5 500 254 UL FM 12 12.539 3.45 10.00 300 323.9 500 254 UL FM 12 12.750 3.45 10.00 VdS 350 377.0 300 279 UL FM 14 14.84 2.07 10.98 400 426.0 300 305 UL FM 16 16.77 2.07 12.00 900 Elbow I 25 33.7 500 57 UL FM 1 1.315 3.45 2.24 VdS 32 42.4 500 70 UL FM 1V 1.660 3.45 2.75 VdS 40 48.3 500 70 UL FM 1 1.900 3.45 2.75 VdS 50 60.3 500 82.5 UL FM 2 2.375 3.45 3.25 VdS 65 73.0 500 95 UL FM 2V2 2.875 3.45 3.74 65 76.1 500 95 UL FM 2½ 3.000 3.45 3.74 VdS 80 88.9 500 108 UL FM 3 3.500 3.45 4.25 VdS 100 114.3 500 127 UL FM 4 4.500 3.45 5.00 VdS 125 133.0 500 122 UL FM 5 5.250 3.45 4.80 125 139.7 500 140 UL FM 5 5.500 3.45 5.50 VdS 125 141.3 500 140 UL FM 5 5.563 3.45 5.50 150 165.1 500 165 UL FM 6 6.500 3.45 6.50 150 168.3 500 165 UL FM 6 6.625 3.45 6.50 VdS 200 219.1 500 197 UL FM 8 8.625 3.45 7.75 VdS 250 267.4 500 . 229 UL FM 10 10.528 3.45 9.00 250 273.0 500 229 UL FM 10 10.750 3.45 9.00 VdS 300 318.5 500 254 UL FM 12 12.539 3.45 10.00 300 323.9 500 254 UL FM 12 12.750 3.45 10.00 VdS 350 377.0 300 279 UL FM 14 14.84 2.07 10.98 400 426.0 300 305 UL FM 16 16.77 2.07 12.00 Tee . '114. 44 (4)' 51, 50 60.3 300 70 UL FM VdS 2 2.375 2.07 2.75 65 73.0 300 76 UL FM 2½ 2.875 2.07 3.00 65 76.1 300 76 ULFMVdS 2½ 3.000 2.07 3.00 80 88.9 300 85.5 MVd UL F S 3 3.500 2.07 100 108.0 300 101 U1 FM 4 4.500 2.07 3.98 100 114.3 300 101 UL FM VdS 4 4.500 2.07 3.98 125 139.7 300 124 UL FM VdS 5 5.500 2.07 4.88 150 159.0 300 140 ULFMVdS 6 6.500 2.07 5.50 150 165.1 300 140 U 1 FM 6 6.500 2.07 5.50 150 168.3 500 140 ULFMVdS 6 6.625 3.45 5.50 200 216.3 300 175 U F UL FM 8 8.625 2.07 6.89 200 219.1 300 175 UL FM VdS 8 8.625 2.07 6.89 Light-duty Tee /AV 0~0_Fu-Mech Jfl:ECH MEIDE CASTING Nag ow 32X15 30 300 54.4 88.9 57.2 318X73 Ut. FM 1YiX1!2 1.18 2.07 2.14 3.50 2.25 32X20 30 300 54.4 88.9 57.2 318X73 Ut. FM 1t4X314 1.18 2.07 2.14 3.50 2.25 32X25 30 300 57.7 88.9 57.2 318X73 UL FM 1t6X1 1.18 2.07 2.27 3.50 2.25 40X15 30 300 57.4 88.9 57.2 3/8X73 UL FM 1V2X1/2 1.18 2.07 2.26 3.50 2.25 40X20 30 300 57.4 88.9 57.2 318X73 Ut. FM 1VA3/4 1.18 2.07 2.26 3.50 2.25 40X25 30 300 60.8 88.9 57.2 318X73 UL FM WWI 1.18 2.07 2.39 3.50 2.25 50X15 30 300 63.3 95.3 57.2 318X90 UL FM 2X1/2 1.18 2.07 2.49 3.75 2.25 50X20 30 300 63.3 95.3 57.2 318X90 UL FM 2X314 1.18 2.07 2.49 3.75 2.25 50X25 30 300 66.6 95.3 57.2 3/8X90 UL FM 2X1 1.18 2.07 2.62 3.75 2.25 65X15 30 300 69.9 108.0 57.2 3/8X105 UL FM 2Y2X12 1.18 2.07 2.75 4.25 2.250 65X20 30 300 69.9 108.0 57.2 3/8X105 UL FM 2VX3!4 1.18 2.07 2.75 4.25 2.250 65X25 30 300 73.2 108.0 57.2 3/8X105 Ut. FM 2½X1 1.18 2.07 2.88 4.25 2.25 65X15 30 300 69.9 108.0 57.2 318X105 * UL FM 76.1X1!2 1.18 2.07 2.75 4.25 2.250 65X20 30 300 69.9 108.0 57.2 3/8X105 Ut. FM 76.1X3!4 1.18 2.07 2.75 4.25 2.250 65X25 30 300 73.2 . 108.0 57.2 318X105 UL FM 76.1X1 1.18 2.07 2.88 4.25 2.25 80X25 38 300 145 73 79 1/2X105 UL FM 3X1 1.5 2.07 5.71 2.87 3.11 100X25 38 300 185 72 89 1/2X125 UL FM 4X1 1.5 2.07 7.28 2.83 3.50 100X32 51 300 185 85 95 112X125 UL FM 4X1V. 2.0 2.07 7.28 3.35 3.74 100X40 51 300 185 85 95 1/2X125 UL FM 4X1V2 2.0 2.07 7.28 3.35 3.74 150X25 38 300 254 75 120 5/8X173 UL FM 6X1 15 2.01 10.00 2.95 4.72 150X32 51 300 254 88 120 518X173 UL FM 6X1Y, 2.0 2.07 10.00 3.46 4.72 150X40 51 300 254 88 120 518X173 UL FM 6X1½ 2.0 2.07 10.00 3.46 4.72 3L 'U-Bolt Mechanical Tee um? Aa Fu-Mech . . DJECll1 MEIDECASTING ... -. ..-_.-. .•.-.... .- .• ... ....,., ,....-. IN f 14 )1i 101110 T ST 02 -14,1111 ILI I HER- IN gg- 4it Lam ILL LL -'f$ 00a1otI ft / 'The AGF Manufacturing Inc. Model 1011A TESTANDRAIN® matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system, with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. The Model 101 1A complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). The Model 101 1A TESTANDRAIN® is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. Available in a full range of sizes from 34" to 2" NPT and BSPT, with all specifiable orifice sizes 3/8" (2.8K), 7A6" (4.2K), ½" (5.6K), 17/32" (8.0K), /8" (11.2K, ELO), 3/4" (14.0K, ESFR), and K25 as required by NFPA .13, 2007 Edi- tion(see reverse). The included UL/FM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-piping outlet. Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1) stem packing, and (1) stem washer are avail- able for all TESTANDRAIN® valves. Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. TESTANDRA)N is a registered trademark of AGF Manufacturing Inc. CS10I1A 10/09 DIMENSIONS MODEL 1011A - FRONT VIEW Orifice Size Available: %",/16", 1/2 ', 17/32", ELO (5/8)*, ESFR (3/4)*, & K25** SIZE A B C 0 E F G H 3/4" 7/l6" 11/2 3/8" 3/8" 113A6" 49/16" 6/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) V. 79/16 i' 11/2" 23A6" 35/8" 33/8" 113/16" 49/16" 63/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4" 715/16" 111/16" 29/16" 41/4" 3/8" 11A6" 59/16" 51/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1Y2" 815A6" 113/16" 31/4" 51A6" 3/8" 25/8" 81/4" 10/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2" 815/16" 113/16" 1 31/4" 51/16" 3/8" 25/8" 81/4" 107/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) *Available on 11/4" to 2" size units only "Available on 11/2" and 2" size units only THE MODEL 1011 PROVIDES ALL OF THE FOLLOWING... From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow.., using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterflow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than 1/2" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve MODEL 101IA - PLAN VIEW MATERIALS Handle: Steel Stem: Rod Brass Ball: C.P. Brass Body: Bronze Valve Seat: Impregnated Teflon® Indicator Plate: Steel Relief Valve: Bronze Bypass Fittings: Brass Bypass Tubing: Nylobraid APPROVALS UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Job Name: Architect: Engineer: Contractor: Specifications Size : 2, 2 lIT, 3. 4!'& 6 Working Pressure : 300 psi (21.5 Bars) Test Pressure 600 psi (43.0 Bars) Working Temperature : - 250°F(- 120C) Install in Both Horizontal or Vertical Position Materials Body : Ductile Iron (ASTM A-536) Seat Ring : Brass (ASTM C37700) Clapper : Stainless Steel (ASTM A-240-304) Rubber Ring * : EPDM Srping Stainless Steel (ASTM A-240-304) Hinge Pin : Stainless Steel (ASTM A-240-304) Flow DueTo Friction Loss Curves .UL, ULC Listed & FM Approved Friction Loss Grooved Check Valve( Water at 65F) . 9.0 C#7 8.0 7.0 .5 6.0 . 5.0 0) 4.0 0 3.0 0) 0. 2.0 a 1.5 2 3.0 0.9 0.0 0.7 0.6 E o 03 Z 100 200 300 400 500 700 1000 20 3000 Flow rate in gallons per minute (GPM) Dimensions unit inch (mm). Lb (Kg) - tf.j,* WtUb/Kg)y - 2" 2.37 (60.3) 6.34 (161.0) 3.54 (90.0) 2.80 (71.0) 5.02 (127.5) 2.37(60.3) 4.21 (107.0) 6.24 (2.83) 21/2" 2.87 (73.0) 7.06 (179.4) 3.91 (99.4) 3.19 (81.0) 5.71 (145.1) 2.87(73.0) 4.74 (120.3) 8.80 (4.00) 3" 3.51 (89.1) 7.80 (198.0) 4.29 (109.0) 3.61 (91.6) 6.44 (163.6) 3.51 (89.1) 5.24 (133.0) 13.23 (6.00) 4' 4.50 (114.3) 8.62 (218.9) 4.06 (103.1) 4.25 (108.0) 7.71 (195.9) 4.50 (114.3) 6.49 (164.8) 19.84 (9.00) 6" 6.63 (168.3) 10.38 (2616) 5.12 (130.0) 5.43 (137.9) 9.56 (242.9) 16.63 (168.3) 1 ann (2na2) 12768(17 nn) F P P I Description FPPI's complete line of TrimFit Forged Brass*, Full Port Ball Valves feature forged components machined to exacting specifications. Listed for fire sprinkler systems for trim, test or drain applications, our Full Port Ball Valves are rated 600 PSI for sizes /2" - 11/2" IPS and 300 PSI for the 2" size. Each valve is complete with plastic coated valve handle marked as required by UL. Blow out proof stem. Installation Installation practices consistent with those of the fire sprinkler industry are appropriate for the installation of this product. Always make sure to properly "hold back" the valve and each component being installed to the valve to prevent over tightening or stressing of the valve body. It is also necessary to make sure all components are in proper alignment in the assembly where the ball valve is present. Improper alignment of attached components may create stress on the valve leading to valve failure. Use a suitable thread sealant such as PTFE tape or PipeFit Thread Sealant Paste with PTFE. Never use tape and paste together. We do not recommend the use of anaerobic sealants with this product. The materials used in this sealant type are highly caustic and may cause failure of the synthetic components present in this product. *UUULC Listed 21397 DO NOT USE MORE THAN ONE SEALANT TYPE PER THREADED CONNECTION. DO NOT OVER TIGHTEN THREADS. OVER TIGHTENING WILL CAUSE LEAKS IN THIS AND OTHER THREADED COMPONENTS. Specifications Nomenclature and Material: Part: Material: Nut Steel Handle Steel Stem Gland Brass* Stem Packing PTFE Stem Brass* Body Forged Brass* Ball Disc Pack PTFE Ball Disc Chrome Plated Brass or Forged Brass* End Plug Forged Brass* Part No.: Size: Take-Out: 06-838-00 1/4" IPS 111/16" 06-840-00 1/2" 21/16" 06-842-00 4" 2%" 06-844-00 2W' 06-845-00 1¼" 3/is" 06-846-00 1½" 3Wi6" 06-848-00 4%" *Full port valves have slightly larger "take out" dimensions than standard port valves. You may need to adjust trim components accordingly. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2015 Fire Protection Products, Inc. Contains lead. Not for use in water systems intended for human consumption. c®us <P LISTED APPROVED Fire Sprinkler Pressure Gauges 0-300 psi water 0-300 psi air 0-300 psi air/water Application: Fluid medium which does not clog connection port or corrode copper alloy. Specifically designed for the fire sprinkler industry. Size: 4" (100 mm) Accuracy ± 31213% of span (ASME B40.1 Grade B) Working Range Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating Temperature Ambient: -40°F to 140°F (-40°C to 60°C) Media: max. 140°F (+60°C) Approvals UL listed (UL-393) FM approved Meets NFPA 25 Standards Temperature Error Standard Scale Additional error when temperature changes from reference temperature of 68°F PSI (20°C) +0.4% for every 18° F (10°C) rising or falling. Percentage of span. Window Standard Features Acrylic, ultrasonically welded to case Connection Material: copper alloy Lower mount (LM) - not available for 1'/2" size Standard Series 'Type 110.1Osp 1/4° NPT limited to wrench flat area Bourdon Tube: Material: copper alloy C-type Movement: Copper alloy, silicone dampened Order Options Dia: White plastic with stop pin - black & red lettering water Pointer: Black aluminum air/water Case: Black polycarbonate air The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -300 to 150°F (-340 to 660C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. SIZE INCHES (mm) VOLTAGE MODEL NO. STOCK NO. CURRENT MAX. TYPICAL dB AT1OFT. (3m) (2) MINIMUM dB ATIOFT. (3m) (1) 6(150) 12VDC PBD126 1706012 .12A 85 76 8(200) 12VDC PBD128 1708012 .12A 90 77 10 (250) 12VDC PBD1210 1710012 .12A 92 78 6(150) 24VDC P8D246 1706024 .06A 87 77 8(200) 24VDC PBD24B 1708024 .06A 91 79 10 (250) 24VDC PBD2410 1710024 .06A 94 80 6(150) 24VAC PBA246 1806024 .17A 91 78 8 (200) 24VAC P8A248 1808024 .17A 94 77 10 (250) 24VAC PBA2410 1810024 .17A 94 78 6(150) 120VAC PBA1206 1806120 .05A 92 83 8(200) 120VAC P8A1208 1808120 .05A 99 84 10 (250) 120VAC PBA12010 1810120 .05A 99 86 I SELLS (E)POTTER PBA-AC & PBD-DC The Symbol of Protection ....... ,,,t.. . UL Listed Sizes Available: 6" (150mm), 8" (200mm) and 1011(250mm) Voltages Available: 24VAC I2OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Potter Electric Signal Company •2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833• www.pottersignal.com PRINTED IN USA MKT. #8850001 - REV S PAGE 1 OF 2 MFG. #5400776-5/05 BELLS (E)POTTER PBA-AC & PBD-DC The Symbol of Protection DIMENSIONS INCHES (mm) FIG. I BELLS FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONE THREADED 1/2"CONDUITENTRANCE - 77 -. I0_ (250) ( (200) 6 (150) \\ ( 2 11/16' () DWG, 9776-1 68 53/4k Q (146) Jill, -4 5/84.1 (41) 5- (127) OWG. fl776-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS WHITE (OUT) RED (OUT) WHITE (IN) OR :EjNDT:-OF-UNE OR 0 0 ORFROM CONTROL PANEL 1ELL FROM CONTROL PANEL (OuT) R PRECEDING BELL 0 BLACK PRECEDING BELL ______________ BLACK BLACK (IN) BLACK (IN) _ CAUTION: WHEN ELECTRICAl. SUPERVISION IS REQUIREO USE IN AND OUT LEADS AS SHOWN. NOTES: 1 • OBSERVE POLARITY TO RING D.C. BELLS. RED WIRES POSITIVE (+) BLACK WIRES NEGATIVE (-) CAUTION: WHEN ELECTRICAl. SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING A.C. BELLS. TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL 2. END-OF-UNE RESISTOR IS NOT REQUIRED ON A.C. BELLS. DWG. #776-3 INSTALLATION The bell shall be installed in accordance with NFPA 72 or local Ahj. The top of the device shall be no less than 90" Aff and not less than 6" below the ceiling. Removethe gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REVS PAGE 2 OF 2 MFG. #5400776 - 5/05 (J VSR POTT ER VANE TYPERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Specifications subject to change without notice. Ordering Information Nominal Pipe Size Mode) Part Number 2" DN50 VSR-2 1144402 2 1/2 DN65 VSR-2 1/2 1144425 3' DM80 VSR-3 1144403 3 1/2" - VSR-3 1/2 1144435 DN100 VSR-4 1144404 - VSR-5 1144405 DM150 VSR-6 1144406 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 General Information The Model VSR is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterfiow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. UL, CUL and CSFM Listed, FM Approved,LPCBApproved,Foi CE Marked (EN12259-5) /VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: I8 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps mm. at24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Non-corrosive sleeve factory installed insaddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. I CAUTION I Waterfiow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. SignalPotter Electric PRINTED IN USA MFG. 95401146 - REV L PAGE I OF 4 3/09 VSR R POTTER. VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. I) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6' (15 cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. I). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. Fig. •••••••••• •4•_Ø••fl DONOTLEAI'ECOVEROFFFOR Retard Adjustment ._---... ANE.r!ENDED PERiOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms TIGHTEN NUTS ALTERNATELY MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF \VATERFLOW CAUTION Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect Le 3 © (3 DIRECTION OF \VATERFLO\V ROLL PADDLE IN OPPOSITE DIRECTION ADAPTEI OFWATERFLO\V (Flowing water aclivales 1 h device in one direction only) DN5O ONLY DWG. I1,46-11 USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DWG 211464F Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts Torque Schedule 10 (UL) Schedule 40 (UL) BS-I387 (LPC) ON (VDS) inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-in VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 +.125/-.062 33.0±2.0 20 27 VSR-2 1/2 2.5 - 2.875 73.0 0.120 3.05 0.203 5.16 - - - - VSR-2 1/2 - 0N65 3.000 76.1 - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DNSO 3.500 88.9 0.120 1 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00±125 50.8±2.0 VSR-31/2 3.5 - 4.000 101.6 0.120 3.05 0.226 534---- VSR-4 4 DNIOO 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 vSR-5 5 - 5.563 141.3 0.134 3.40 0.258 6.55 - - - - - VSR-6 6 DNISO 6.625 1683 0.134 3.40 0.280 1 7.11 0.197 5.0 0.157 4 VSR-8 8 DN200 8.625 219.1 0.148 3.76 0.322 1 8.18 1 0.248 6.3 0.177 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG. #5401146 - REV L PAGE 2 OF 4 3/09 Fig. 2 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. ME 00101 . jIi46-& Fig. 7 Mounting Dimensions 3.50 in 2.00 (89.0mm (50.8 234 (59.4 mm)}Ij P DIA. U-BOLT NUT U.BOLTWASHER ) + 5.25 in _____________ (+ 133.4 mm) PIPE SADDLE-1 PtPE— PLASTIC PADDLE— Fig. 8 GREEN GROUND OVG 1146-14 I .1 VSR rd VA P, POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Fig. 4 Switch Terminal Connections Clamping Plate Terminal \ An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8' of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. f(4)56 ______ _______ ;EOLR N - Fig. 5 Typical Electrical Connections CE POWER The Model VSR has two switches, one can be used to operate a central SUITABLE BELL SU station, proprietary or remote signaling unit, while the other contact Notes PANEL is used to operate a local audible or visual annunciator. WATERF A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. WATE LOW ZONE For supervised circuits, see "Switch Terminal Connections" drawing and warning note (Fig. 4). OWait4.12 - - -, Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activatethis device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. U.BOLT__1_______________________ NOMINAL PIPE DIA. +1.75 in (+44.5 MM) FOR ON SO- ON 652-2.5 in .. own 1146-15 -- NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR ON 80- ON 200 3-8 in PRINTED IN USA MFG. 95401146 - REV L PAGE 3 OF 4 3/09 a VSR G.': POTTER VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance - Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 6). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 6) gTtSJtfgJ The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe I. Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken out of service. Disconnect the power source for local bell (if applicable). Identify and remove all wires from the waterfiow switch. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. Re-install the (2) original mounting screws. Reconnect all wires. Perform a flow test and place the system back in service. Fig. 6 REMOVE (2) ORIGINAL MOUNTING scws HOLDING RETARD/SWITCH .-"ZASSEMBLYTO BASE BREAKOUTTHINSECTION OFCOVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING RETARD/SWITCH ASSEMBLY r CREWS DO NOT REMO (2) RETARD HOI. SCREWS (2) LOCATTh (2) LOCATII' BOSSES IN DWG# 1146-10 Removal of Waterfiow Switch To prevent accidental water damage, all control valves should be shut tight and the System completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. Lift detector clear of pipe. PRINTED IN USA MFG. #5401146-REV L PAGE 4 OF4 3/09