HomeMy WebLinkAbout6211 EL CAMINO REAL; ; FPC2021-0049; Permit4LCity0f PERMIT REPORT Carlsbad Print Date: 06/17/2021 Permit No: FPC2021-0049 Job Address: 6211 EL CAMINO REAL, CARLSBAD, CA 92009-1604 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2131001500 Track #: Applied: 04/08/2021 Valuation: $55,114.35 Lot #: Issued: 04/22/2021 Occupancy Group: Project #: Finaled Close Out: 06/17/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: MILLIPORE SIGMA - ALTERATION TO EXISTING FIRE ALARM SYSTEM (2 HORNS/STROBES) FPContractor: iii ENTERPRISES SALOMON GOMEZ 115 MARKET PL ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 x216 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Duet $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, -Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov MTE!ISES FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS MILLIPORE SIGMA T.I. 6211 EL CAMINO REAL FIRE ALARM SYSTEM cjMATERIAL DATA SHEETS SYSTEM SENSOR Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95,115,150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Agency Listings SIGNAUNG LISTED S5512 FM approved except 71 25-16534504 $4011 for ALERT models 3057383 - The System Sensor L-Series, offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings wall and ceiling mounting options, System Sensor L-Series can meet virtLally any application requirement. The entire L-Serias proiuct line of ceiling-mount strobes and horn strobes include a varie:y of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming groJnd faults. To further simplif, instaiation, the L-Series utilizes a universal mounting plate s;D installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requ-emen:s using field-selectable candela settings, automatic selection of 2- or 24-vct operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SynceCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Seriesproducts shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light-shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range . 10 to 93% non-condensing Strobe Flash Rate 0 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18AWG Ceiling-Mount Dimensions (including lens) 6.8 diameter x 25 high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9 diameter x 3.4 high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) . Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AV0S86800 UL Current Draw Data IIIETIMMIR. I-ImMN M-1 I'M II ----- wIi 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 DC Input 8-17.5 Volts 15cd 30cd 16-33 Volts 15cd 30cd 75cd 95cd 11 5c 150cd - 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1KTemporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Switch Position Sound Pattern ----------------...,- dB --•---.---- 8-17.5 Volts DC --•- 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AV0S86800 L-Series Dimensions 2.47 1.37 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes SCRL Strobe, Red PC2RL 2-Wire, Horn Strobe, Red SCWL Strobe, White PC2WL 2-Wire, Horn Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White 5 TElVi 3825 Ohio Avenue • St. Charles, IL 60174 .. ©2Ol7SysIeflSensor. P Product specifications cat ass subject arc rothcut nobce. teat systetesensor.cronr SEItJSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 current product nfroroatro AVOS8 rr. including the thtest versroo & this data sheet. O8Oi • 03/I7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL rl ff _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE N7 LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc 3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneyweIl.com DESIGN: Systeni Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *p4\fJj Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: - BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walllrim Rings: *TR2 and *TR2W Ceilinglrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is- not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDCIFWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division