HomeMy WebLinkAbout6211 EL CAMINO REAL; ; FPC2021-0007; PermitPERMIT REPORT 4LCIty of Carlsbad Print Date: 06/21/2021 Job Address: 6211 EL CAMINO REAL, CARLSBAD, CA 92009-1604 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers' Parcel #: 2131001500 Track #: Valuation: $0.00 Lot U: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Project Title: Description: MILLIPORE SIGMA SPRINKLER TI (8 HEADS UNDER MEZZANINE) Permit No: FPC2021-0007 Status: Closed - Finaled Applied: 01/21/2021 Issued: Finaled Close Out: 06/21/2021 Inspector: Final Inspection: Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MICHAEL LOVELY 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 x1727 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov .000000 I cosco S. ..•I. S... •.• Fire Protection San Diego Branch Office 4990 Greencraig Lane San Diego, CA 92123 (858) 444-2000 fax: 444-2056 CA Lic.: C-16 #577621 www. coscofi re. corn MATERIAL SUBMITTAL Date: 1-19-2021 MILLIPORE MEZZANINE T.I. 6211 EL CAMINO REAL CARLSBAD, CA 92008 JOB # 1O.CA_ All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: MJ Lovely Los Angeles • San Francisco 0 Orange • Fresno • San Diego • Seattle Page 1 of 6 "J II(IIS1E® MICROFAST® QUICK l.1:II[.1iu,7w RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcscvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 [) VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 C) LPCB Approved: Certificate 096e106 WARNING: Cancer and Reproductive Harm- www.P65Warnings.ca.gov CE Certified: Standard EN 12259-I, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-CII000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G Form No. F033314 19.10.14 Rev 19.2 Replaces Form No. F_033314 Rev 19.1 (Added ENT; updated FM language.) Page 2 of 6 MICROFAST® QUICK l:II[.u.LIv RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A %" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap- Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F033314 19.10.14 Rev 19.2 Page 3 of 6 MICROFAST® QUICK NIKJNG4® RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135 OF (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Ml Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) .40 Carefully slide the wrench sideways around the protective cap, ensuring engagement with -111114— the sprinkler wrench flats Figure 2: Wrench 13655W1B for Recessed Pendent Sprinklers Form No. F033314 19.10.14 Rev 19.2 Page 4 of 6 MICROFASTO QUICK J lKIF1Gj SPRINKLER VK302 (K5.6) l.l:lI[.,i..7Iv RESPONSE PENDENT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart .1 (UL) The Viking Microfast® Quick Response KEY Finish Pendent Sprinkler VK302 A3X—Eon(ftapplibI Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals3 Part SIN K-Factor Length (Refer also to Design Criteria.) Number1 I Style NPT 7B—SP U.S. metric2 Inches mm cULus4 VdS LPCB CE 8 I:: 12979 VK302 Pendent 1/2° 15 MIT 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, C1Y Dl 19780 VK302 Pendent 1/2° -- 5.6 80.6 2-1/4 58 -- -- -- -- -- D3 21354 VK302 Pendent - 15 mm 5.6 80.6 2-1/4 58 -- -- -- -- -- 03 i.iti uct Below - Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1/2° 1 15 mm 5.6 1 80.6 1 2-1/4 58 A1Z, B1Y, D2, C2X 1 AIX, B1Y -- I -- I -- 18021 IVK3021 Pendent 1 1/2" 1 15 mm1 5.6 1 80.6 1 2-1/4 58 I Al I AIX, B1Y I DIX, CIY7 Dl Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175°F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 OF (93 °C), 286 OF (141 °C) Polyester56, Black Polyes- Viking MicromaticP Model E-1 Recessed Escutcheon B - 135 OF (57 °C), 155 OF (68 °C), 175 OF ter56 V - Standard surface-mounted escutcheon or recessed with the Viking Micromatic (79 °C), and 200°F (93 °C) 2- ENT5 Model E-1, E-2, or E-3 Recessed Escutcheon C - 155 OF (68 °C), 175 OF (79 °C), and 3-Chrome Z - Standard surface-mounted escutcheon 200 OF (93 °C) O - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), 286 OF (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-50021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA - _UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F033314 19.10.14 Rev 19.2 Page 5 of 6 MICROFAST® QUICK Kj _; l:II[.1u'7..Th RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY I The Viking Microfase Quick Response nnisi . Rx~ Pendent Sprinkler VK302 I Escutcheon cpØcabte) Maximum 175 PSI (12 Bar) WWP ----- Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 L.),E.E - Product Below Limited y. 7iiii7 Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Temperature Ratings Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F X - Standard surface-mounted escutcheon or the (93 SC), 286 F (141 °C) Approved Finishes Viking Micromatic Model E-1 Recessed Escutcheon B - 135 ¶ (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 1 -Brass, Chrome, White Polyester4, Y - Standard surface-mounted escutcheon or recessed 200 F (93 C) and Black Polyester' with the Viking Micromatic Model E-1 or E-2 C - 155 ¶ (68 °C), 175 °F (79 °C), 200 ¶ (93 °C), 286 2 - ENT5 Recessed Escutcheon °F (141 °C) Z - Standard surface-mounted escutcheon D - 155 ¶ (68 °C), 175 ¶ (79 °C), 200 °F (93 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation auidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F033314 19.10.14 Rev 19.2 Page 6 of 6 MICROFAST® QUICK %I N 1KJI1G iU'7W RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum NPT Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon 1-i 2-1/8" (54 mm) 1-3/4" (45 mm) Max. - 1-1/8" ia (29 mm) 2.... Mm. (51 mm) Max RUFF Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 1-1/8" (29 mm) Mm. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 19.10.14 Rev 19.2 Replaces Form No. F_033314 Rev 19.1 (Added ENT; updated FM language.) ot Cock Cover Check Mo' 7O900DAOSY beat LJIb(.. ES-7O9DCDA Job Name - Contractor Job Location Approval Engineer - Contractor's P.O. No. Approval - Representative Series 709DCDA Double Check Detector Assemblies Sizes: 3" -10" Series 709DCDA Double Check Detector Assemblies are designed exclusively for use in accordance with water authority containment requirements. It is mandatory to prevent the reverse flow of fire protection system substances, i.e. glycerin wetting agents, stagnant water and water of non-potable quality from being pumped or siphoned into the potable water line. Benefits: Detects leaks. . . with emphasis on the cost of unaccountable water; incorporates a meter which allows the water utility to: Detect leaks underground that historically create great annual cost due to waste. Provide a detection point for unauthorized use. It can help locate illegal taps. Modular check design concept facilitates maintenance and assembly access. All sizes are standardly equipped with resilient seated OSY shutoff valves, 5/s" x 3/4" meter and ball type test cocks. Features Body construction fused epoxy coated cast iron Replaceable bronze seats Maximum flow at low pressure drop Compact for economy combined with performance Design simplicity for easy maintenance Furnished with %" x 3/4" bronze meter No special tools required for servicing Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a potable water supply. Degree of hazard present is determined by the local authority having jurisdiction. The unit shall be a complete assembly including UL listed resilient seated OSY shutoff valves and test cocks. The unit shall be UL/FM approved with UL/FM approved OSY shutoff valves. The auxiliary line shall consist of an approved backflow preventer and water meter. The assembly shall meet the basic requirements of ASSE 1048; A'MNA Std. C510 for Double Check Valves. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be a Watts Series 709DCDA. Check Assembly Module Features a modular design concept which facilitates complete maintenance and assembly by retaining the spring load. First and second check valve spring modules are not interchangeable. Now Available WattsBox Insulated Enclosures. For more information, send for literature ES-WB. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Inquire with governing authorities for local installation requirements please contact Watts Technical Service. Watts reserves the right to change or modily product design, construction, specifications, or materials with- Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequentty sold. X%IWATM Materials Body: Seat: Disc Holder: Trim: Check Valve Discs: Test Cocks: Models Suffix: Epoxy coated cast iron Bronze Bronze Stainless steel Rubber Bronze OSY ULJFM outside stem and yoke resilient seated gate valves CFM cubic feet per minute meter GPM gallons per minute meter LF 4' - 10" without shutoff valves Dimensions - Weights Pressure - Temperature Temperature Range: 33° F - 110°F (05 - 43°C) continuous, 140°F (60°C) intermittent Maximum Working Pressure: 175p5i (12.1 bar) Standards AWNA Standard 0510 Approvals S <@> NU-1c ,CP C U Approved QD 13.64 io Approved by the foundation for Cross-Connection Controland Hydraulic Research at the University of Southern California. Sizes 4" - 10° approved for horizontal and vertical "flow up'. Size 3" approved for horizontal only. Factory Mutual approved 4" - 10" vertical "flow up". A------------------------------------------------- SIZE DIMENSIONS WEIGHT In. in. A mm C in. mm D in. mm in. E mm in. L mm in. A mm I in. mm in. U. mm W/OSYt gates lbs. kgs. 3 40 1016 18% 479 3½ 89 12 305 24 610 14 356 3 76 14 356 190 86 4 52 1321 223/4 578 33/4 95 17 432 34 864 15 381 6 152 14 356 403 183 6 1 621/2 1588 1 301/8 765 41/2 114 21 533 411/2 1054 16 406 7½ 191 16 406 727 330 8 75 1905 373/4 959 1 51/2 140 26 660 52 1321 17 432 1 9 229 1 21 533 1327 602 10 90 2286 1 453/4 1162 1 61/2 165 32 813 64 1626 18 457 1 101/4 260 1 25 635 2093 949 * Service clearance for check assembly from center. tULJFM approved backflow preventers must include UL/FM approved OSY. Capacity *Typical maximum system flow rate (7.5 ft/Sec.) **UL rated flow .T. FT ....... l_.._...._.. jJ,uI a...... i••••• iii•i' ...... i••= ==__. ______ t•i• A•••U •••••i•••••• __.___ III ••••••i••••• .____ I lI l'I .I1I lI Il -UI •11 F•iIi== i•__ ---- ---- LI I II Il II Il II 9111 .lII1I •jlil jMI ------ __I UI •i ---- ! r ;I •!' III,, j' IUI ____ • i•• i•i• ._ i____.• 'UiN U &II ._ I____.• .T. I mui I I I • 1. %VWATIS® USA: T: (978) 689-6066 • F: (978) 975-8350 • Watts.com Canada: T: (905) 332-4090 • F: (905) 332-7068 • Watts.ca Latin America: T: (52) 81-1001-8600 • Watts.com ES-709DCDA 0638 © 2019 Watts WARNING Cancer and Reproductive Harm- wwwP65Warnings.ca.gov Expansion Plate G-1 Escutcheon Ai Form No. F_122698 19.08.12 Rev. 19.1 Replaces Form No. F_122698 Rev. 18.P65 (Removed F-i Escutcheon) Page 1 of 9 SPRINKLER ESCUTCH- "\j I I(IF1G ® SPR EONS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking sprinkler escutcheons are ornamental plates used with 3/8" NPT (10 mm BSP)*, ½" NPT (15 mm BSP)*, and 3/4' NPT (20 mm BSP)* frame-style pendent and sidewall* sprinklers. The escutcheons are installed between the sprinklers and the ceiling or wall for a pleasing appearance. They are available with several finish options to meet design requirements. Viking recessed and adjustable escutcheons provide a low-profile decorative re- cessed sprinkler installation. The E-i Recessed Escutcheon may be recessed up to 5/8" (16 mm). The Model G-1 Recessed Escutcheon allows horizontal sidewall Ail& E-1 Escutcheon sprinklers to be recessed up to 1/2" (13 mm). The two-piece design of Viking's recessed and adjustable escutcheons allows in- stallation and testing of the sprinklers prior to installing the ceiling or wall. Viking's ( Model E-1 and G-1 Escutcheons feature a slip-on design, while the Model E-2 and E-3 escutcheons are threaded (outer cup threads onto the adapter). The Viking adjustable and recessed escutcheons are made to allow for minor E-2 Escutcheon adjustments due to pipe or ceiling pitch. These escutcheons can be removed and reinstalled, allowing access above removable ceiling panels for servicing building equipment without shutting down the sprinkler system and removing the sprinkler. Viking standard 1/8" (3 mm) style flat and 1" (25 mm) style raised surface-mount- ed escutcheons have a one-piece design. *Refer to the specific sprinkler technical data page for the escutcheon(s) listed and approved for use with the sprinkler. E-3 Escutcheon 2. LISTINGS AND APPROVALS Refer to the specific sprinkler technical data pages for sprinkler listings and approvals. Sprinklers must be specifically listed and/or approved for recessed installation. When using Viking Model E-1, E-2, E-3, and G-i escutcheons for recessed applications, refer to technical data describing the sprinkler model to be used to verify whether the sprinkler is listed and/or approved for recessed installa- tions. NOTE: Viking's thread-on style Model E-2 and E-3 Recessed Escutcheons Raised Surface Mount Escutcheon carry the same listings and approvals as the slip-on style Model E-1 Recessed Escutcheons. Model E-3 Recessed Escutcheon also meets IBC-ASCE/SEI 7 Now Codes for Seismic Areas C, D, and E. Flat Surface Mount Escutcheon Page 2 of 9 I N F(lF1G l.I:II[.1.iu.Lw SPRINKLER ESCUTCH- EONS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking sprinkler escutcheons are ornamental plates used with 318" NPT (10 mm BSP)*, 1/2" NPT (15 mm BSP)*, and %" NPT (20 mm BSP)* frame-style pendent and sidewall* sprinklers. The escutcheons are installed between the sprinklers and the ceiling or wall for a pleasing appearance. They are available with several finish options to meet design requirements. Viking recessed and adjustable escutcheons provide a low-profile decorative recessed sprinkler installation. The E-1 Recessed Escutcheon may be recessed up to 5/8" (16 mm). The Model G-1 Recessed Escutcheon allows horizontal sidewall sprinklers to be recessed up to 1/2" (13 mm). The two-piece design of Viking's recessed and adjustable escutcheons allows installation and testing of the sprinklers prior to installing the ceiling or wall. Viking's Model E-1 and G-1 Escutcheons feature a slip-on design, while the Model E-2 and E-3 es- cutcheons are threaded (outer cup threads onto the adapter). The Viking adjustable and recessed escutcheons are made to allow for minor adjustments due to pipe or ceiling pitch. These escutcheons can be removed and reinstalled, allowing access above removable ceiling panels for servicing building equipment without shutting down the sprinkler system and removing the sprinkler. Viking standard 1/8" (3 mm) style flat and 1" (25 mm) style raised surface-mounted escutcheons have a one-piece design. *Refer to the specific sprinkler technical data page for the escutcheon(s) listed and approved for use with the sprinkler. LISTINGS AND APPROVALS Refer to the specific sprinkler technical data pages for sprinkler listings and approvals. Sprinklers must be specifically listed and/or approved for recessed installation. When using Viking Model E-1, E-2, E-3, and G-1 escutcheons for recessed applications, refer to technical data describing the sprinkler model to be used to verify whether the sprinkler is listed and/or approved for recessed installations. NOTE: Viking's thread-on style Model E-2 and E-3 Recessed Escutcheons carry the same listings and approvals as the slip-on style Model E-1 Recessed Escutcheons. Model E-3 Recessed Escutcheon also meets IBC-ASCE/SEl 7 Codes for Seismic Areas C, D, and E. TECHNICAL DATA Specifications: Slip-on Style Model E-1 Recessed Escutcheons Depth of Outer Cup: 1-1/16" (27 mm) Outside Diameter of Outer Cup: 3-1/16" (78 mm) Depth of Center Adapter Ring: 11/32" (9 mm) +1- 1/32" (1 mm) Adjustment Range: Flush to 5/8" (16 mm) recessed NOTE: Escutcheon adapter is stamped "Viking Model E-1". Available since 1987. Threaded Style Model E-2 Recessed Escutcheons Depth of Outer Cup: 13/16" (21 mm) Outside Diameter of Outer Cup: 3-1/8" (80 mm) Depth of Center Adapter Ring: 21/32" (17 mm) Adjustment Range: 27/32" (21 mm) total adjustment with %" (13 mm) maximum recess available. NOTE: Face of escutcheon adapter may extend up to 11/32" (9 mm) beyond edge of escutcheon cup. Available since 2000. Threaded Style Model E-3 Recessed Escutcheons Depth of Outer Cup: 13/16" (21 mm) Outside Diameter of Outer Cup: 5-1/8" (130 mm). Depth of Center Adapter Ring: 21/32" (17 mm) Adjustment Range: 27/32" (22 mm) total adjustment with ½" (13 mm) maximum recess available. Note: Face of escutcheon adapter may extend up to 11/32" (9 mm) beyond edge of escutcheon cup. Form No. F122698 19.08.12 Rev. 19.1 Page 30f9 INKLER ESCUTCH- "NJ SPR EONS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Available since 2012. D. Slip-on Style Model G-1 Recessed Escutcheons (US Patent No. 8,376,060) Depth of Outer Cup: 1-1/16" (27 mm) Outside Diameter of Outer Cup: 4" (102 mm) Depth of Center Adapter Ring: 1-7/16" (37 mm) Adjustment Range: Up to 5/8" (16 mm) total adjustment available for use with ceilings sloped up to 8/12 (33.7°). May be recessed up to 1/2' (13 mm), depending on degree of slope. NOTE: The face of escutcheon adapter may extend up to 1/2" (13 mm) beyond the edge of the escutcheon cup. NOTE: Escutcheon adapter is stamped Viking Model G-1". Available since 2007. E. Expansion Plate (optional) Base Part No. 12620 for use with Model E-1 and E-2 Escutcheons. May also be used with dry recessed sprinklers, dry standard adjustable sprinklers, and flat plate concealed sprinklers. Outside Diameter: 5" (127 mm) Inside Diameter: 2-3/16" (56 mm) Available since 2005. Base Part No. 13128 for use with Domed Concealed Sprinklers. Outside Diameter: 5" (127 mm) Inside Diameter: 2-15/32" (63 mm) for Part No. 13128. Available since 2005. Base Part No. 16340 for use with Concealed Sprinkler VK636. Outside Diameter: 5-5/16" (135 mm) Inside Diameter: 2-3/8" (61 mm) Available since 2010. F. Standard Flat and Raised Surface-Mounted Escutcheons Depth of Escutch'eons: Flat: 1/8" (3 mm), Raised: 1" (25 mm) Available since 1972. Material Standards: Slip-on Style Model E-1 Recessed Escutcheons: Cold Rolled Steel UNS-G10080 or Stainless Steel UNS-530400 Threaded Style Model E-2 and E-3 Recessed Escutcheons: 24 ga. (1 mm) thick 1010-1018 mild steel Model G-1 Recessed Escutcheons Adjustable Escutcheons: Cold Rolled Steel UNS-G10080 Expansion Plate (optional): Cold Rolled Steel UNS-G10080 Standard Flat and Raised Surface-Mounted Escutcheons: Flat Style Part Numbers 01960A, 01015A, 02960A, and 05464A: Cold Rolled Steel UNS-G10080. Flat Style Part Numbers 09488, 07526, and 09596*: Stainless Steel UNS-543000 * These may also be special ordered and manufactured from Brass (nonmagnetic material). Contact the manufacturer for more information. Raised Style Part Numbers 01961B and 01016A: Brass UNS-C26000 or UNS-C26800. Ordering Information: (Also refer to the current Viking price list.) Viking recessed and adjustable escutcheons are available as escutcheon packages (includes outer cup and adapter). Order Viking escutcheons by adding the appropriate suffix for the finish to the base part number. Model E-1, E-2, E-3, and G-1 Recessed Escutcheons: To order as an escutcheon package (includes outer cup and adapter), specify the appropriate package part number from Table 1. Standard Flat and Raised Surface-Mounted Escutcheons: Specify the flat or raised escutcheon part number from Table 1. Finish Suffix: Bright Brass = B, Polished Chrome = F, White Polyester = M-/W, and Black Polyester = M-/B. Form No. F_122698 19.08.12 Rev. 19.1 Page 4 of 9 1IF(IFs1G® l:IIs1.i.,JW SPRINKLER ESCUTCH- EONS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com For example, the Model E-1 Recessed Escutcheon for 1/2" NPT sprinkler, Brass finish = Part No. 06419AB. The 1/2" Model E-1 Recessed Escutcheon is also available in Antique Brass, Brushed Copper, Brushed Chrome, and Brushed Brass as standard finishes. NOTE: Sprinklers are not included and must be ordered separately. 4. INSTALLATION If the proposed installation of Model E-1, E-2, E-3, or G-1 Escutcheons requires recessing any of the heat-sensitive operating el- ement, some Authorities Having Jurisdiction may limit the use, depending on the occupancy classification. Refer to the Authority Having Jurisdiction prior to installation. The use of quick response sprinklers may also be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. All escutcheon styles are made to thread onto the sprinkler head prior to installing the sprinkler into the filling. The escutcheon must be attached to the sprinkler prior to applying pipe-joint compound or PTFE tape to the sprinkler threads. NOTE: Sprinklers with protective caps or bulb shields must be contained within the caps or shields before applying pipe-joint compound or tape. Refer to the appropriate sprinkler technical data page for additional warnings and installation instructions and then install the escutcheons according to the following sequence. Model E-1, E-2, E-3, and G-1 Recessed Escutcheons: (Refer to Figures 1-5.) Step 1: Install all piping and cut the sprinkler nipple so that the reducing coupling is at the desired location and centered in a minimum 2-5/16" (59 mm) to a maximum 2-1/2" (64 mm) diameter opening in the ceiling or wall for Model E-1 or E-2 Escutcheons, 2-5/16" (59 mm) to 4-1/2" (115mm) for Model E-3, or 2-5/8" (66 mm) to 3-3/4 (95 mm) for Model G-1 Escutcheons. Step 2: Secure the escutcheon adapter onto the sprinkler by hand turning the adapter clockwise onto the sprinkler threads. The face of the adapter should rest on the shoulder of the sprinkler wrench boss. Step 3: Apply a small amount of pipe-joint compound or PTFE tape to the external threads of the sprinkler only, taking care not to allow a build-up of compound in the sprinkler inlet. NOTE: Sprinklers with protective caps or bulb shields must be contained within the caps or shields before applying pipe-joint compound or tape. Step 4: Install the sprinkler into the coupling using the special recessed sprinkler wrench only, taking care not to over-tighten or damage the sprinkler operating parts. DO NOT use the escutcheon, sprinkler deflector, or fusible element to start or thread the sprinkler into a filling. Step 5: Test the system as required and repair all leaks. If a thread leak occurs, normally the unit must be removed, new pipe- joint compound or PTFE tape applied, and then reinstalled. This is due to the fact that when the joint seal leaks, the sealing compound or tape is washed out of the joint. Step 6: Remove plastic protective sprinkler caps and bulb shields AFTER the wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operat- ing elements. To remove the bulb shields, simply pull the ends of the shields apart where they are snapped together. To remove caps from frame style sprinklers, turn the caps slightly and pull them off the sprinklers. SPRINKLER CAPS AND BULB SHIELDS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Retain a protective cap in the spare sprinkler cabinet. Step 7: After installing the ceiling or wall with the required opening size, press on or thread on (depends on the style of escutch- eon used) the outer escutcheon cup until the flanges touch the surface of the ceiling or wall. (NOTE: If the optional escutcheon expansion plate is used, first slide it onto the escutcheon cup. The flange on the expansion plate should touch the surface of the ceiling or wall.) With the slip-on style Model E-1 Recessed Escutcheon, the maximum adapter recess is 5/8" (16 mm). With the threaded style Model E-2 and E-3 Recessed Escutcheons, the maximum recess is /2" (13 mm). Note: The face of the escutcheon adapter may extend up to 11/32" (9 mm) beyond edge of escutcheon cup, resulting in 27/32" (21 mm) total adjustment range. With the slip-on style Model G-1 Recessed Escutcheon, the maximum adapter recess is 1/2" (13 mm). DO NOT modify the unit. If necessary, re-cut the sprinkler drop nipple as required. Form No. F_122698 19.08.12 Rev. 19.1 Page 5 of 9 ® "I IF(IIIG l:IIEu.Lw SPRINKLER ESCUTCH- EONS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Standard Flat and Raised Surface-Mounted Escutcheons: Step 1: Install all piping and cut the sprinkler nipple so that the reducing coupling is at the desired location and centered in a maximum 2-1/2" (64 mm) diameter opening in the ceiling or wall. Step 2: Secure the escutcheon onto the sprinkler by hand turning the escutcheon clockwise onto the sprinkler threads. (The convex surface of the escutcheon must face toward the deflector of the sprinkler.) Step 3: Apply a small amount of pipe-joint compound or PTFE tape to the external threads of the sprinkler only, taking care not to allow a build-up of compound in the sprinkler inlet. NOTE: Sprinklers with protective caps or bulb shields must be contained within the caps or shields before applying pipe-joint compound or tape. Step 4: Install the sprinkler into the coupling using the special sprinkler wrench only, taking care not to over-tighten or dam- age the sprinkler operating parts. DO NOT use the escutcheon, sprinkler deflector, or fusible element to start or thread the sprinkler into a fitting. Step 5: After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the installation standards. Make sure the sprinkler is properly tightened. If a thread leak occurs, normally the unit must be removed, new pipe-joint compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal leaks, the sealing compound or tape is washed out of the joint. Step 6: Remove plastic protective sprinkler caps and bulb shields AFTER the wall or ceiling finish work is completed where the sprinkler is installed and there no longer is a potential for mechanical damage to the sprinkler operat- ing elements. To remove the bulb shields, simply pull the ends of the shields apart where they are snapped together. To remove caps from frame style sprinklers, turn the caps slightly and pull them off the sprinklers. SPRINKLER CAPS AND BULB SHIELDS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE! Retain a protective cap in the spare sprinkler cabinet. DO NOT modify the unit. If necessary, re-cut the sprinkler drop nipple as required. Disassembly: The outer cups of Viking adjustable and recessed escutcheons can be removed and reinstalled without removing the sprinklers to allow access above the ceiling or to replace it, if necessary. For slip-on style Model E-1 or G-1 Recessed Escutcheons, remove the outer cup simply by pulling it outward and away from the wall or ceiling. To remove the outer cup of the threaded style Model E-2 and E-3 Recessed Escutcheons, turn it counterclockwise to un- thread it from the adapter. If it is necessary to remove the entire unit, the system must be removed from service. Refer to maintenance instructions on the appropriate sprinkler technical data page and follow all warnings and instructions. OPERATION Refer to the sprinkler technical data page for the sprinkler model used. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking sprinklers and escutcheons are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_122698 19.08.12 Rev. 19.1 Page 6 of 9 IF(IF1Gi ll:II[.1u'Lm SPRINKLER ESCUTCH- EONS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Base Part Number I Material I Style I Sprinkler Thread Size I Available Finishes I Outside Diameter Standard Flat and Raised Surface-Mounted Escutcheons 01960A Steel Flat 112" (15 mm) B, F 3-5/16" (84 mm) 09488 Stainless Steelft Flat 1/2" (15 mm) F, JN 3-5/16" (84 mm) 01015A Steel Flat 3/4" (20 mm) F 3-5/16" (84 mm) 02960A Steel Flat 1/2" (15 mm) B, F, MIW, M/B 2-3/4" (70 mm) 07526 Stainless Steeltt Flat 1/2" (15 mm) F, MAN, JN 2-3/4" (70 mm) 05464A Steel Flat 3/4" (20 mm) B, F, MAN 2-3/4" (70 mm) 09596 Stainless Steeltf Flat 3/4"(20 mm) F, JN 2-3/4" (70 mm) 01961B Brass Raised 1/2" (15 mm) F 3-1/16" (78 mm) 01016A Brass Raised 3/4" (20 mm) F 3-1/16" (78 mm) E-1 Slip-on Style Recessed Escutcheon Packages (includes adapter and outer cup) 11123 Steel Recessed Slip-on 3/8" (10 mm) F, MAN 3-1/16" (78 mm) 06419A Steel Recessed Slip-on 1/2" (15 mm) B, F, MAN, M/B 3-1/16" (78 mm) 07902 Stainless Steel Recessed Slip-on 1/2" (15 mm) F, MAN, JN 3-1/16" (78 mm) 20123 Stainless Steel Recessed Slip-on 3/4" (20 mm) F, MAN, JN 3-1/16" (78 mm) 20369 Steel Recessed Slip-on 3/4" (20 mm) B, F, MAN, M/B 3-1/16" (78 mm) E-2 Threaded Escutcheon Packages (includes adapter and outer cup) _Style _Recessed 11038 Steel Recessed Threaded 1/2" (15 mm) F, MAN 3-1/8" (79 mm) 20130 Steel Recessed Threaded 3/4" (20 mm) F, MAN 3-1/8" (79 mm) E-3 Threaded Escutcheon Packages (includes adapter and outer cup) _Style _Recessed 18347 Steel Recessed Threaded 1/2" (15 mm) F, MAN 5-1/8" (130mm) 20135 Steel Recessed Threaded 3/4" (20 mm) F, MAN 5-1/8" (130mm) G-1 Recessed Escutcheon Package (includes adapter and outer cup) 14315 Steel Recessed Slip-on 1/2" (15 mm) B, F, MAN, M/B 4" (102 mm) 20133 Steel Recessed Slip-on 3/4"(20 mm) B, F, MAN, M/B (102 mm) Optional Expansion Plates Available Separately 12620 Steel E-1, E-2 Recessed (10, 15,&20 mm) B, F, MM, MMSBWl64I (127 mm) 13128 Steel Domed Concealed 1/2" & 3/4" (15 & 20 mm) F, MAN 5" (127 mm) 16340 Steel Concealed (for Sprinkler VK636) 3/4" (20 mm) F, MAN 5-5/16" (135 mm) Escutcheon Finishes: B = Bright Brass, F = Polished Chrome, MAN = White Polyester, M/B = Black Polyester, JN = Electroless Nickel PTFE, MI SW1641 = Navajo White Paint, B/A = Antique Brass, B/B = Brushed Brass, F/B = Brushed Chrome, EJB = Brushed Copper. Note: Other colors are available on request with the same listings and approvals as the standard colors. See Sherwin-Williams® Color AnswersTM Interior Color Selection color chart. ttEscutcheons 09488, 07526, and 09596 may also be special ordered and manufactured from Brass (non-magnetic material). Contact the manufac- turer for more details. Table I Form No. F_122698 19.08.12 Rev. 19.1 :h: mm) (1 mm) Adjustable Adapter Ring 2-1/8" Adjustable (54 mm) Outer Cup 1:t16 (27 mm) 3-1/16" (3 mm) (78 mm) Ceiling/Wall Opening: 2-5/16" (59 mm) Minimum 2-1/2" (64 mm) Maximun io (ID mm; ion: I) Page 7 of 9 'tj I KJ SPRINKLER ESCUTCH- EONS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs®vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com IMPORTANT NOTES Per the current edition of NFPA 13: "Escutcheons used with recessed, flush-type, or concealed sprinklers shall be part of a listed sprinkler assembly." The Viking Corporation will not authorize the sale of unlisted recessed sprinkler assemblies nor assume any liability involving recessed sprinkler assemblies that are not considered cULus Listed, FM Approved, or in full compliance with NFPA requirements". Listings and approvals vary, depending on the sprinkler model, temperature rating, finish, and occupancy classification. I WRN1NG]I Viking products are manufactured and tested to meet the rigid requirements of the approving agency. The sprinklers are de- signed to be installed in accordance with recognized installation standards. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: painting , plating, coating, or modification, may render the sprinkler inoperative and will nullify the approval and any guarantee made by The Viking Corporation. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to the ap- propriate sprinkler data page. Viking sprinklers are designed to be installed in accordance with the latest edition of Viking technical data, the latest standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards whenever applicable. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. Figure 1: Installation of a Slip-on Style Model E-1 Recessed Escutcheon with 5/8" (16 mm) Maximum Recess. Form No. F_122698 19.08.12 Rev. 19.1 Maximum Recess: 1/2" (13 mm) Ceiling/Wall Opening: 2-5116" (59 mm) Minimum 2-11211 (64 mm) Maximum Threaded Adjustable 2-118" Outer Cup 13/16" (21 mm) 3132" Iuii____ 3-1/8" Jpr] (79mm) (2mm) : I A iI Maximum Extension: 1 11/32" (9mm) I Maximum Extension: 11/32" (9mm) Page 8 of 9 NIwI(I l:II[.11u'Lw SPRINKLER ESCUTCH- i I EONS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Depth: 21132" Threaded Adjustable (17mm) Adapter Ring—\ , Figure 2: Installation of a Thread-on Style Model E-2 Recessed Escutcheon with 27/32" (21 mm) Total Adjustment. I Ll Threaded Adjustable Adapter Ring , T, T ll!_']_~e~', Allows 1" (25 mm) Depth: Annular Space for 21/32" Seismic (17 mm) Applications Ceiling/Wall Opening: 2-5/1611 (69 mm) Minimum 4.1/2" (115 mm) Maximum Maxlum Recess: 1/2" (13mm) Threaded Adjustable 2-1/8" Outer Cup (54_'!I1i 4, - 1 13/16" 1. (21 mm) _____________ 3/32" 4 (2 mm) (130 mm) Figure 3: Installation of a Thread-on Style Model E-3 Recessed Escutcheon with 27/32" (21 mm) Total Adjustment. Form No. F_122698 19.08.12 Rev. 19.1 Page 9 of 9 NIKJW SPRINKLER ESCUTCH- EONS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Adjustable Outer Cup 1/8" (3 mm) Adjustable Outer Cup Maximum Recess: 1/2" (13 mm) 2-5/8" 4" (66 mm) (102 mm) (27 mm) Figure 4: Installation of the Model G-1 Recessed Escutcheon with up to 1/2" (12.7 mm) Adjustment. Quick Response HSW Sprinkler installed with the Model 0.1 Recessed Escutcheon Keep the leading edge of the HSW deflector parallel with the ceiling Shown with sprinkler installed at the peak of a sloped ceiling with spray directed down the slope. (Refer to the appropriate sprinkler technical data page for listings and approvals.) Figure 5: Model G-1 Recessed Escutcheon Installed with a Residential HSW Sprinkler below a sloped ceil Form No. F_122698 19.08.12 Rev. 19.1 Replaces Form No. F_122698 Rev. 18.P65 (Removed F-i Escutcheon) tIED APPROVED 'Approval Details and Umilations, eebslta at wvov.anvllintl.cem or Anvil' Sales Representative. NVIL DUCTILE IRON THREADED FITTINGS .(~)AWIL FIG, 3201 900 Elbow FIGURE 3201 I 900 ELBOW Nominal Size Maximum I Dimension A Approx. Wt. Each Working PressureA In. (mm) PSI (kPo) In. (mm) Lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 1/4 500 1.75 0.90 32 3450 44.45 0.41 1½ 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 50 3450 57.15 0.84 A - Working Pressure Ratings are for reference only and based on Scn. 40 pipe. For the latest U1/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASIM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/UIC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATI ON APPROVALI1Vii' Project: . DApproved Address: 0 Approved as noted Contractor: . El Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1 .15 4E~NVIL DUCTILE IRON THREADED FITTINGS (~)Ar*JVIL FIG, 3224 Cap I [A FIGURE 3224 - CAP Nominal Size I Maximum Working PressureA Dimension A I Approx. WI. Each In. (mm) PSI (kPo) In. (mm) Lbs. (kg) 1 500 1.16 0.32 25 3450 29.46 0.15 Fl4 500 1.28 0.43 32 3450 32.51 0.20 P12 500 1.33 0.60 40 3450 33.18 0.21 2 500 1.45 0.91 50 3450 36.83 0.41 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. c®uS € USTED APPROVED For Listings/Approval Details and Limitations, visit our website at www.snvilivlt.com or contact an Anvil' Solos Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile sfrength.than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: 1J Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: - Notes 1: Notes 2: SPF/01-1 .15 NVIL DUCTILE IRON THREADED FITTINGS (~)AWIL FIG, 3221R Reducing Coupling c®vs USTED APPROVED For Ustings/Approval Details and Umitatlons, visit our website at www.anvllinll.com or contact an Anvil' Sales Representative. FIGURE }*iI: REDUCI NG I,i1IJ1IRl[c Nominal Size MaximumDimension A Approx. Wt. Each Working PressureA In. (mm) PS! (kPo) In. (mm) Lbs. (kg) 1 x Vs 500 1.69 0.39 25x!5 3450 42.92 0/8 1 xY4 500 1.69 0.53 25x20 3450 42.92 0.24 1/4 x Y4 500 2.06 0.64 32x20 3450 52.32 0.29 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASIM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening con cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than Four turns. PROJECT INFORMATI ON APPROVAL STAMP Project: J Approved Address: []Approved as noted Contractor: U Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-5.1 9 FM Approved and Fully Listed Sprinkler Pipe Wheatland's A53 Schedule 40 steel fire sprinkler pipe is UL® Listed and FM Approved, sizes 1-6 NPS, for use in fire sprinkler pipe applications, and is suitable for welding, threading and grooving. 8 NPS Schedule 40 is FM Approved but not UL Listed. Approvals and Specifications The product meets or exceeds the following standards: ASTM A53, Type F, Grade A, 1-4" ASTM A53, Type E, Grade B, 2-8' ASME B36.10M Federal Specification WW-P-404 Manufacturing Protocols The weld seam of Wheatland's A53 ERW Grade B is heat- treated after welding to 1,400° F; we slowly cool the steel in order to toughen it and reduce its brittleness. Our products are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Wheatland's SureThreadT° standard steel pipe is hot-formed and heated during tube formation-not just the edges. As the coiled steel reaches 2,450° F, rollers bend the steel into a cylindrical shape, and the pressure and heat fuse the edges together. There are no flash forms in this process, allowing for a continuous weld. It all adds up to an extremely strong yet easily machinable pipe. Our 1-4" SureThread product is a full- bodied annealed product. Finishes and Coatings The average weight of zinc coating shall not be less than 1.8 ounces per square foot of surface (inside and outside). When galvanized pipe is bent or otherwise fabricated to a degree that causes zinc coating to stretch or compress beyond the limit of elasticity, some flaking of the coating may occur. Wheatland's MIC SHIELD'" antimicrobial coating, when initially applied to the inner wall of the pipe, acts as a sanitizing agent WEIGHTS AND DIMENSIONS CHART NOM. OD NOMINAL WT./FT. WT./LBS. NPS INCHES WALL H2O FILLED FT. 11 1.315 0.133 2.052 1.68 11/4 1.660 0.140 2.919 2.27 11/2 1.990 0.145 3.601 2.72 2 2.375 0.154 5.109 3.66 21/2 2.875 0.203 7.871 5.80 3 3.500 0.216 10.783 7.58 4 7 4.500 0.237 16.311 10.88 5 5.563 0.258 23.262 14.63 6 6.625 0.280 31.498 18.99 8° 8.625 0.322 50.210 28.58 8 NPS Schedule 40 is FM Approved but not UL Listed @ C@ <.~P.OVE>D to clean the contact surface. MIC SHIELD coating thereafter adheres to the pipe wall, serving as a protective coating that guards against contamination by impeding the attachment of microbes to the pipe wall. This limits the opportunities for corrosion from microbiological organisms in the water supply when the sprinkler pipe is initially installed. The integrity and benefits of this protection can be preserved through a combination of additional and routine treatment options outlined in NFPA 13. MIC SHIELD coating is available for Wheatland black steel pipe, sizes 1-6" and 8" upon request. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Bar coding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: - - WIS080416 700 South Dock Street infowheaUand.com Sharon, PA 16146 wheatland.corn 1J Wlieatland Tube P 800.257.8182 Follow us on Twitter: A DIVISION OF ZEKELNAN INDUSTRIES F 724.346.7260 - dWheatlandTube USTSD APPROVED itngslApproval Details and Limitations, our website at www.anvitintl.com or act an Anvil' Sates Representative. 4E~~~ DUCTILE IRON THREADED FITTINGS ANVIL FIG. 3205 Straight Tee Ir A A --1 FIGURE 3205 1I:1.[ci:Ii ill Nominal Size Maximum Dimension A Approx. Wt. Each Working Pressurea. in. (mm) PSI (kPo) In. (mm) Lbs. (kg) 1 500 1.50 0.85 25 3450 38.10 0.39 P/4 500 1.75 1.22 32 3450 44.45 0.55 1½ 500 1.94 1.55 40 3450 49.27 0.70 2 500 2.25 2.45 50 3450 1 57.15 1 Ill A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest ULJULC, and FM pressure ratings versus pipe schedule, please visit onvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: LJApproved as noted Contractor: El Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1 .15 C®US LISTED Fig. 25 - Surge Restrainer Size Range - One size fits 3/4' thru 2' pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed çn!y when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4' thru 2". Patent #5,344,108 / I 1: : 3 I; II II •' if Iii (II I: / 1. ,•—..• \ __./ OFFICE/MANUFACTURING FACIUTY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com NOTICE TO PROSPECTIVE BUSINESSES - STATEMENT OF INTENDED USE Various processes and situations in commercial and industrial establishments can create fire and life safety hazards. In order to provide a reasonable degree of safety to life and protection of property, specific requirements have been established in the Fire, Building, and Life Safety Codes. This is not intended to be a complete list, but merely a tool to help us assist you in assessing your business as a fit in our community and suitability in a particular building. You are encouraged to exercise your right to ask questions of the property owner or leasing agent, of neighboring businesses and of all City departments. To help us assess what particular laws apply to your business, please provide the following information: PART I - Building Information Business Name: rev%e-p- Business Address: (,J/' Number of Buildings: 1 Type of Construction: Square Footage: 7tvo PART II - Questionnaire [Yes] [No] Will your store or handle an aggregate quantity aerosol products in excess of 500 lbs. [Y] [)] Will you install or operate a stationary lead-acid battery system more than 100 gallons. [Y] [)C] Will you produce dust or loose combustible fibers in excess of 100 cubic feet. [ Y ] [')4 Will you be storing more that 2500 cubic feet of combustible materials (boxes, rubber). [Y] [>K] Will you store, handle or use compressed gases; (Table 105-A) [ N] Will you produce, store or handle crvogens. (Table 105-13) [Y] [X Will you engage in the business of dry cleaning. [Y] ['] Will you conduct an operation which produces combustible dusts (i.e. flour, magnesium). VN [ N] Will you have any explosives or blasting agents. [ Y ] [] Will you store, handle, use or dispense flammable or combustible liquids. [ N] Will you store, transport on site, dispense, use or handle hazardous materials. (Table 105-C) [$ [ N] Will you have over 500 square feet of high-piled combustible storage. (>12 feet) [Y] [)(] Will you store, handle or use liquefied petroleum gases (LPG). [ Y ] Will you melt, cast, heat treat or grind more than 10 lbs. of magnesium. [Y] 14 Will you have a motor vehicle fuel-dispensing station. [Y] [J Will you manufacture more than 1 gallon of organic coating per day. [Y] [)] Will you operate an industrial baking or drying oven. N] Will you operate a place of assembly (Drinking, Dining, or Gathering) for more than 50 people. [Y] [)(j Will you store or handle radioactive materials. [j [ N] Will you have a refrigeration system with >220 lbs. Group Al or >30 pounds of any other refrigerant. [Y] 21. Will you operate a repair garage for servicing or repairing automobiles. [Y] [(] 22. Will you be conducting hot work (welding, cutting or use flame producing devices or torches). [ Nri 23. Will you apply flammable or combustible liquids (Spray booth, Dip tank, Powder Coating, Rolling). [Y] 24. Will you store over 1000 cubic feet of tires in an outside area. [ Y ] [] 25. Will you store, lumber, wood chips, hogged material or plywood in excess of 200 cubic feet. [Y] [J 26. Is your building equipped with automatic fire sprinklers. If YES then: ,)eJ [ N ] Calculated sprinkler system GPM/Sq.Ft. Design Area (i.e. 3/3000 Density and certification information can usually be found on labels on the main sprinkler system riser for each system) Pipe Schedule (non-calculated) sprinkler system, Date system installed ,2. 00 Early Suppression Fast-Response (ESFR) sprinkler system - PSI / ESFR /K Factor Other type Sprinkler System - list type and location: Date of last sprinkler system 5 year certification (Title 19 OCR): L C20JO D Fire sprinkler alarm monitoring company: 5-ka.......) ej L;/ S 27. Is your building equipped with automatic fire detection (smoke detector, heat detector, manual pull). ] [N ] Date of last alarm system certification: Alarm monitoring company: -54- 4-,., I Sec Lu_riv c/..dIO nA5 ) PART Ill - Intended Use Statement Number of employees: I qq Hours of operation: S Joji M . 9 L T W 7 2 'I AfF2,4 S - gJ1 Describe the method of disposing of combustible or hazardous waste materials: SUBMIT LETTER: Submit a signed, legible letter (preferably type written and on your company's letterhead) stating your intended use for the property. In the letter, describe materials you will be storing and using on the property. Explain the method of storage (e.g. racks, pallets), storage dimensions, and where the materials will be located on the property. Describe how you will be using the materials. Explain any alterations to the building that are planned. (See attached example). SUBMIT SITE PLAN/FLOOR PLAN: Submit site plan drawn to rough scale showing the property size and location, building size and location on property: both in square feet. Show all exit doors, fire extinguishers, fire hose cabinets, special fire or life safety systems, and any item(s) marked "yes" in Part II. (See attached example). FIRE EXTINGUISHER REQUIREMENTS: Light Hazard occupancy (office, classrooms, medical offices, etc.) Provide a minimum of (1) 2A10BC rated fire extinguisher mounted in an accessible conspicuous area. One extinguisher is required for every 6000 square feet and the travel distance to afire extinguisher shall not exceed 75 feet from any point. Ordinary Hazard occupancy (mercantile storage, dining areas, and display, warehouses, light manufacturing) Provide a / minimum of (1) 2A2013C rated fire extinguisher mounted in an accessible conspicuous area. One extinguisher is required for every 3000 square feet and the travel distance to a fire extinguisher shall not exceed 75 feet from any point. Extra Hazard occupancy (Hazardous Materials, flammable liquid, vehicle repair, cooking areas, woodworking uses) Provide a minimum of (1) 4A4013C rated fire extinguisher mounted in an accessible conspicuous area. One extinguisher is required for every 2000 square feet and the travel distance to a fire extinguisher shall not exceed 50 feet from any point. []Kitchen Hood System - One Class K fire extinguisher shall be placed within 30 feet of all grease cooking operations in a commercial kitchen. (No "A or C" rating shall be mounted near kitchen hood system.) NOTE: These are typical minimum requirements. The inspector may require more fire extinguishers due to special operations or processes being used. For example spray booths, special electrical hazards, exotic metals, and other situations will require increased protection. 7. HAZARDOUS MATERIALS DECLARATION )( THIS BUILDING WILL USE HAZARDOUS MATERIALS IN EXCESS OF NON-REPORTABLE AMOUNTS. []THIS BUILDING WILL NOT USE HAZARDOUS MATERIALS OR USES NON-REPORTABLE AMOUNTS. NON-HANDLER DECLARATION A hazardous material may be broadly defined as any material that because of its quantity, concentration, or physical or chemical characteristics; poses a significant, present, or potential hazard to human health and safety, property, or to the environment. A hazardous material includes, but is not limited to any substance or material which the handler or the administering agency has a reasonable basis for believing would be injurious a person's health and safety or harmful to the environment if released into the work place or surrounding areas. By signing below, I declare that the above named business, organization, or occupant will not handle a hazardous material or mixture containing hazardous material which has a quantity at any one time during the reporting year equal to, or greater than, a total weight of 500 pounds, or a total of 55 gallons, or 200 cubic feet at standard temperature and pressure for compressed gas. Print Name and Title of Declarer: Declarer Signature: Fire Department Representative:____________________________________________________________________________ PART IV - High Piled Combustible Storage: In Article 2 of the City of Carlsbad Fire Code, high pile combustible storage is defined as: Storage of combustible materials [product and/or packaging] in closely packed piles (floor storage) or combustible materials on pallets, in racks, or on shelves where the top of storage is greater than 12 feet in height. High piled combustible storage also includes certain high hazard commodities, such as rubber tires, group A plastics, flammable liquids, idle pallets, and similar commodities, where the fop of the storage is greater than 6 feet in height. It is very important to contact our office prior to consideration of storing high-piled combustible storage. Many of the permit requirements must be built into your building. If your building is not approved for high-piled combustible storage it may be cost prohibitive. For example; if you have a pipe schedule sprinkler system - no high piled storage is permitted until the system is calculated. A fire inspector can assist you with fire department requirements. THIS BUILDING WILL NOT BE USED FOR HIGH-PILED COMBUSTIBLE STORAGE. THIS BUILDING WILL BE USED FOR HIGH-PILED COMBUSTIBLE STORAGE. "Permit is Required." Contact the Carlsbad Fire Department for permit requirements. THIS BUILDING IS A SPECULATION BUILDING WITHOUT A TENANT AT THIS TIME. The tenant will be notified to contact the fire department prior to use of the building. TO OBTAIN A STAMP FROM THE FIRE DEPARTMENT YOU MUST BRING THE FOLLOWING ITEMS TO THE FIRE PREVENTION OFFICE: THIS FORM COMPLETED, A SIGNED, LEGIBLE LETTER (PART III, NUMBER 4.) A SITE PLAN/FLOOR PLAN (PART III, NUMBER 5.) FIRE DEPARTMENT STAMP: THE FOLLOWING PERMITS ARE REQUIRED: PERMIT INFORMATION SHEETS WILL BE PROVIDED FOR REQUIRED PERMITS. PERMITS WILL ONLY BE ISSUED BY A FIRE INSPECTOR. PLEASE CONTACT OUR OFFICE AT 760.602.4660 TO SCHEDULE AN INSPECTION. Occupant Emergency Information See reverse side for explanations GENERAL INFORMATION: Business Name: 2'i, -. on fia / DBA/AFA/FKA: Effective Date: Street Address Suite/Apt - City: Cpr-/$Jct.d State: C/i' ZIP+4:g2cx9 new construction, name change, or ownership change: a new occupant moving in and the previous'occupant/business has moved out sharing the above address with another occupant/business by the name of: Mailing Address (only if different than above): Phone: _____ ext Fax: _________________________________________________ Generic E-mail: Number of employees: i46 Senior Person: 130 f'tCCoff9tI-_Title: ,,C0 cIlj/7( /tlq(- Describe Property Use: Hazardous Material: - Notes/Special Concerns: Thomas Guide: Cross Street: City License/Permit #: Fire Station #: Phone: _____ Water Company: Zone: PROPERTY INFORMATION: Landlord/Property Owner Name: - S Phone: _____ Address: Contact Person Name: Title: Occupancy Code: Roof Type: SOFT: Stories: _______HPS: _______ HPM:________ Fire Sprinklers: Basement: ___Target Hazard: HM Handler: FD Permit: EMERGENCY CONTACT INFORMATION: (24 Hour number - usually home phone) 1st Person to contact: 7?ei.e.Voh u..v-c Title: _ /fv Phone: (7(0) q3(,-359' 1 2nd Person to contact: Fn IA_/tc Title: oct Ili y /tfcjr Phone:(7iO) 7,-9Jc?g 3rd Person to contact: Title: kC19V Phone: (S7') Alarm Company: 3 *,i 4_Phone: L LJpT1 Li I F'LJ r1EJ ___ I R i rE1 '4 14 'a 1 4 I IILiLJi I - I Ir WINSOME I ! i[u1u1u] I X- Ili S ..