HomeMy WebLinkAbout2208 PALOMAR AIRPORT RD; ; FPC2020-0145; PermitPERMIT REPORT Qty of Carlsbad Print Date: 06/17/2021 Job Address: 2208 PALOMAR AIRPORT RD, CARLSBAD, CA 92011 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2130201800 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0145 Status: Closed - Finaled Applied: 08/20/2020 Issued: 10/05/2020 Finaled Close Out: 06/17/2021 Inspector: Final Inspection: Project Title: Description: WESTERN FLIGHT HANGERS -REVISION TO PLANS TO REPLACE BAD FIRE ALARM PANEL (2208/2210 PALOMAR AIRPORT RD) Applicant: FPContractor: COSCO FIRE PROTECTION INC COSCO FIRE PROTECTION INC JAMES GRIMES 1075W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (619) 508-9701 FEE AMOUNT FIRE Plan Review Per Hour - Office Hours $136.00 FIRE Reinspection (per inspection) . $193.00 FIRE Sprinkler Monitoring $383.00 FIRE Sprinkler Monitoring AddI Inspection $136.00 Total Fees: $848.00 Total Payments To Date: $848.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314-1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov . Fire alarm system cut sheets & California State Fire Marshal Listing sheets for: WESTERN FLIGHT 2208 & 2210 PALOMAR AIRPORT ROAD CARLSBAD, CA 92011 cosco. S. .,•S S .• Fire Protection 4990 GREENCRAIG LANE SAN DIEGO, CA 92123 (858) 444-2000 L S 0 Kidde Catalog Small Building Fire Alarm Solutions United Technologies Technology that saves lives Conventional Fire Alarm Systems FX-1ORD, FX-1OR, FX-5RD, FX-5R FDNY COA 6230 Overview These systems incorporate features designed to simplify installation, operation and maintenance, including front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with CleanMe® -compatible smoke detectors, these con- trol panels provide intelligent type features such as remote mainte- nance alert and automatic drift compensation that significantly reduce the chance of a false alarm and simplify maintenance calls. Kidde systems are powerful enough to meet the demands of today's life safety installations while leaving plenty of room to grow in the future. They support Class A operation by combining pairs of on-board lDCs or NACs to provide the necessary Class A circuits. For example, the FX-10RD comes factory set to support 10 Class B lDCs and 4 NACs. But it can be field-configured to provide 5 Class A lDCs (no Class B IDC's), and 2 Class A NACs - or any other com- bination of circuits that fall within the circuit-pairing parameters. Standard Features Available in 5, and 10 zone (IDC) models CleanMe® feature provides remote annunciation of a dirty detector Automatic drift compensation with select detectors reduces false alarms and extends dust life Listed to ANSI/UL 864 9th Edition Models with fully integrated upload/download DACT enables PC programming Zone or NAC pairs convertible to single Class A circuits Combination Waterflow and Supervisory lDCs NACs programmable by zone and individually selectable for notification appliances, continuous, temporal outputs, or coded Front panel programmable simplifies installation and servicing Precision synchronization with compatible notification appli- ances and optional audible silence over two wires a On-board relays for Alarm, Supervisory and Trouble Optional serial bus relay modules are programmable for Com- mon, Zone, or Matrix activation Optional serial bus remote annunciator family One person walk-test (audible or silent) Optional City Tie and Reverse Polarity Modules Trim ring available for semi-flush mounting Kidde brand conventional fire alarm systems consist of 5 and S 10 zone fire alarm control panels (FACP), an optional integrated upload/download DACT (dialer), intelligent/analog type detec- tor features, serial annunciator modules, and serial remote relay modules. All FACPs and components are Listed to the 9th edition of the ANSI/UL 864 standard and CSFM/FDNY approved. 11 FX-10RD FX-5RD Class BlDCs Up to 10 Upto5 Class AlDCs Upto5 Upto2 Class BNACs Upto4 Upto2 Class A NACs Up to 2 1 NAC Power 7.0 amps 3.5 amps Auxiliary power 0.5 amps 0.5 amps Notes: Class A operation will reduce the number of available Class 8 W and/or NACs, depending on the panel configuration. See Specifications for details. S Page 1 of 8 DATA SHEET K85005-0126 Not to be used for Installation purposes. Issue 1 Application Kidde conventional fire alarm systems provide smoke and fire de- tection, occupant notification and off-premises signaling for small- to medium-sized buildings. Each IDC can be configured for either Class B or Class A opera- tion and one of eight operating modes: Alarm —with or without smoke detector verification including discrimination of contact devices Waterflow Alarm; Waterilow Alarm/Supervisory (Combination IDC); Supervisory (Latching/non-latching); Monitor (non alarm or supervisory) Signal Silence Drill Cross zoning NACs may also be configured for either Class B or Class A operation. Additionally, NACs can be individually configured for one of six outputs. These are Genesis, Genesis (AN silenceable), Continuous, Temporal, Coded, and City Tie. The Genesis selec- tion allows independent horn control over two wires and provides precision synchronization of notification appliances, all without the need for a signal master accessory. When configured for compatible notification appliances, the Alarm Silence function will silence connected audible appliances but strobes will remain active until the panel is reset. When Genesis Mode is selected, both the horns and strobes on compatible notifi- cation appliances will be synchronized across all NACs. Note: Zones may be selected for either latching or non-latching operation. Always check with your AHJ regarding approval of silencing audible while leaving strobes flashing. Panel LED Display The following system LEDs display the panel's status: Alarm - panel is in the alarm state; Trouble - panel is in the trouble state; Supervisory - panel is in the supervisory state; Power - indicates the status of the AC power source; Disable - indicates when any IDC, NAC, relay or the DACT is disabled; Annunciator Trouble - indicates trouble on the remote an- nunciator bus; Battery Trouble - indicates battery or charging problems; Ground Fault - indicates a short between any panel circuit and ground; Walk Test - indicates that one or more lDCs are in the walk test mode; Alarms Silenced - indicates that the panel is in the alarm state with one or more NACs silenced. Water/low - indicates that one or more circuits have detected an active waterilow switch. Service Detector - indicates the presence of a dirty detector with CleanMe® compatible ESL smoke detectors. Remote Disconnect - indicates off site communication has been disabled. Each IDC has a disable switch and three LEDs: Alarm - red - indicates that the IDC is in the alarm state; Trouble - ye/low - indicates that the IDC is in the trouble state or is disabled (when flashing); Supervisory/Monitor - yellow - indicates that the IDC is in the supervisory state or the monitor state (when flashing). Each NAC also has a disable switch and a trouble/disable LED. Detectors with intelligent features at a conventional price When combined CleanMe® - -compatible smoke detectors, - Kidde systems provide intel- ligent features at a conventional i5iicélfa CleanMe® detector drifts out of the UL sensitivity range, Kidde's patented remote maintenance reporting sends an alert to the control panel. This feature reduces the chance of a false alarm and simplifies service calls. In addition, CleanMe® -compatible smoke detectors have built-in drift compensation that extends the time between cleanings. If cleaning is ever necessary, it is literally a snap with the Kidde exclusive replaceable optical chamber. For a complete list of CleanMe® compatible smoke detectors, visit http.-IlKidde-fire.com. Status indication with the DACT/Dialer installed The optional upload/download dialer's LCD display provides two lines x 16 characters of text. For programming, the top line displays the programming step and the lower line displays the selected option. All system events are displayed on the LCD with custom zone messages. During normal operation, the LCD will display-any-off-normal condition present in the panel. S Page 2 of 8 DATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 The Remote Relay Module mounts on a plastic track inside an MFC-A cabinet. Uptotwo RRM24s can be mounted in an FSRRM-St I snap track Up to two FSRRM-St Is can be mounted in an su,puoc M MFc-A. S Power Connections N L Cabinet Main AC From 120 Vac, 15 A, 60 Hz wiring block Dedicated branch circuit and fuse '•1 holder II Fuse Dual transformer 0 AC wiring block\ N2 '0 1 L2 ee N L o o / Main Tie wrap Main controller mounts transformer board 181 o o © o' Mounting studs J4 o o ® ' Plug connector Upload/Download DACT/Dialer Options Off-premise communication A fully integrated upload/download dialer is available for reporting events to a monitoring facility. The DACT also supports uploading or downloading of system configuration, status and event history. The DACT is programmable for either single or dual line opera- tion. It also supports split and dual reporting for two digital alarm receivers. The DACT brings additional features to the panel including a 32-character alphanumeric LCD display, local or remote PC pro- gramming and an event history log. Remote Annunciators and Relays The serial bus standard on Kidde conventional control panels is another installation time-saver. This circuit allows the connection of Remote System Indicators (FSRSI), Remote Zone Indicators (FSRZI- A, FSRZI-SA) and Remote Relay Modules (FSRRM24) over a four- wire (data and power) circuit. Annunciator and relay modules can be installed up to 1,000 feet from the panel on 18-gauge wire. Modules are also available for City Tie (CTM) and Reverse Polarity (RPM) connections. Remote Relay Module fl The DACT/Dialer installs be- hind the front panel display. Note: All panel versions are available with factory installed DACT See order table for ordering informa- tion. The built-in DACT/Dialer is a multifunc- tion module that provides communi- cations, modem Capability, and LCD display functions. Its primary function is as a Digital Alarm Communica- tor Transmitter (DACT). As a DACT, it transmits event messages to a Digital Alarm Communicator Receiver (DACR) at a monitoring facility. The monitoring facility then notifies the fire department and other responsible parties of the event. Programmable options include split or dual reporting to two DACRs. The DACT module can also be used as a modem to connect the panel to both local and remote computers for uploading and downloading of con- figuration data (programming), panel status and event history. For security, the modem can be configured to ac- cept programming on incoming calls or it can be required to call a prepro- grammed number before accepting downloads and sending uploads. The DACT module can be configured to work as all of the above, or as only an LCD display or LCD display and modem. The Remote Relay Module (FSRRM24) is one feature of the system that sets these systems apart from other panels in their class. This module has five Form C relays rated at 1 amp each. It can be configured to function in either a zone relay mode or a common system mode. When configured in the zone relay mode, relays energize when the as- sociated IDC is active. The module can be configured for activation by lDCs 1 through 5 or lDCs 6 through 10. One relay is automatically associated with - each IDC. When configured in the common system mode, relays energize or de-energize when the panel changes state. One relay is available OopflOol 000105 TO 005,00*. cou.ions,o.l for each of the following 05oo.005ouroj functions: Alarm, Supervi- sory, Trouble, Power Loss, Monitor. 240101C IN-UT SOouu I our, I C SCINO C Nd I I Puw.ru01 1 I po.0,o,On To n.ed.Vc. The FSRRM24 mounts on a plastic snap track and can be installed in an MFC-A enclosure. The panel will support two RAMs of each configuration for a total of six on the 10-zone panel. Page of 8 K85005-0126 Issue 1 FSRA10, FSRA10C Wiring From control panel or 24V0C Supply From control panel Page 4 of 8 F 24V - Il 11.ij•i•jjijPIII iUil! I F MIN RI_iiiiU ,FBIIE 24V 24V To next remote module C C ON: Group 1 OFF: Group 2 Remote Annunciators — This family of systems has several remote annunciation options. The serial remote annunciator bus can be run up to 1000 feet (305 m) on untwisted - non-shielded 18-gauge cable. Several annunciator models round out the - family to provide a range of features and functions. As many as three an- nunciator modules may be mounted in a standard electrical box, sharing an attractive trim plate that blends with any decor. T The FSRSI can be installed alone or with one or more FSRZI-As. The FSRSI and FSRZI-A require trim plates (ordered separately). These are available in one, two or three gang models. Each panel will support two FSRSls. — Remote Zone Indicator r (FSRZI-SA) — The FSRZI-SA indicates — zones in the Alarm or Su- pervisory state. It contains five red and yellow LEDs for Common, Zone, or Matrix activation. Depending on the >— jumper setting, the LEDs will indicate either lDCs 1- 5 or 6 >— - 10. The panel supports two T1lIj modules for each selection, and can be jumper selected IL to provide Alarm or Supervi- sory sory indications. — Remote System Indicator — Remote Zone Indicator (FSRSI) (FSRZI-A) The FSRSI is ideal for The FSRZI-A is used to common system annuncia- — indicate zones in the alarm tion. It includes five LEDs state. It contains five red and a local silence/lamp -, LEDs. Depending on the test switch. The LEDs mdi- — jumper setting selected, cate power status, alarm, - -- the LEDs will indicate either supervisory, trouble and >...., lDCs 1 through 5 or lDCs 6 ground fault. The silence co...-.x. through 10. The panel can i switch will silence the support two modules pro- onboard trouble sounder grammed for each selection. ifactive. The switch can V IN i IN also be used to initiate a lamp test of the LEDs on all connected FSRSls and FSRZI-As. pan. d To Ca dm10. f I TOn.x,d*. FSUIM Graphic Driver/Interface The FSUIM is a universal interface module that can be used by to drive graphic annunciators. It also allows control panels to control, or be controlled by, other control panels. The FSUIM provides five supervised switch inputs and nine dry contact relay outputs. Nine LEDs provide visual confirmation when each relay is energized. The FSUIM is shipped with a plastic snap track for mounting in an MFC-A enclosure. K85005-0126 - Issue 1 FSRA10, FSRA10C Remote LED annunciators The FSRA10 is a remote annunciator with capacity for up to ten zones. It includes ten bi-color LEDs (red/yellow) for indicat- ing active zones, and ten yellow LEDs for indicating zone troubles. The (C) option adds common control switches. Both ver- sions mount to standard North American 4-inch square electrical boxes. A surface box is also available. Works only with 10 zone panel. From Control panel Or ZOVDC powe, supply From Control panel or ZCVDC ow pe, supply Control panel I Remote Annunciator Specifications ___ _____ rGeneral - - Agency Listings I UL864 (S3000), ULC, CSFM [Remote Anunis - -FSRS1oti itor FsRzu:NFsRzI-sKnote Zone Iditfl Maximum per System All panels: 2 10 zone panel: 4 5 zone panel: 2 Current Requirements Standby: 17 mA Alarm: 56 mA Standby: 8 mA Alarm 76 mA Voltage Range Minimum: 18.8 Vdc; Maximum: 27.3 Vdc Maximum Circuit Capacitance - 0.03 pF Maximum Circuit Resistance 13 Ohms Wire Size 18- 12 AWG (0.75 mm2 - 2.5 mm2) Mounting - ANSI/NEMA OS 1-1996 1-3 gang electrical box Operating Environment Temperature: 32 - 1200 F (0- 490 C); Humidity: 93% RH, non-condensing [o ay WuFSRRM24 Configured for Common Mode Maximum per system 10 zone panel: 4; 5 zone panel: 2 All panels: 2 Current Requirements Standby: 10 mA; Alarm: 70 mA Standby: 26 mA; Alarm: 70 mA Voltage Range - Minimum: 18.8 Vdc; Maximum: 27.3 Vdc Contact Rating 1 A@ 30 Vdc Maximum Circuit Capacitance 0.03 pF Maximum Circuit Resistance 13 Ohms Wire Size 18- 12 AWG (0.75 mm2 -2.5 mm2) oun ing Mounting Single FSRRM24 mounts in plastic track (included) or up to two FSRRM24s in an FSRRM-S1 111" track ordered separately. FSRRM24s should be installed in an MFC-A enclosure. Operating Environment Temperature: 32 - 120° F (0 - 490 C); Humidity: 93% RH, non-condensing Dimensions 2-3/4° W x 3-3/8" H x 1-1/2° D (65.9 mm W x 85.7 mm H x 38.1 mm D) ------------------------------ F-Series Remote Annunciators - FSR-AIO . FSRA10C Common Controls No - I Yes Compatibility - 10-Zone Panels Only. Dimensions 5-5/8" x 81/2" x 1 ½" in (14.3 cm x 21.4 cm x 3.8 cm) Mounting North American 4-inch square electrical box Power Wiring 18 to 12 AWG (0.75 to 2.50 sq mm) Data Wiring 18 to 12 AWG (0.75 to 2.50 sq mm) twisted pair (6 twists per foot minimum) Operating voltage 18.8 to 27.3 Vdc Supply must be UL/ULC listed for fire protective signaling systems. Do not use FACP accessory power outputs that are interrupted when the panel is reset. Standby current - 17 mA Alarm current 98 mA Operating environment Temperature: 32 to 120 °F (0 to 49 °C); Humidity: 0 to 93% RH, noncondensing at 90 °F (32 °C) FSUlMUniversaIInputModule -- - - - -- - Mounting MFC-A enclosure Wire size 12 to 18 AWG (0.75102.5 sq mm) Operating voltage 21.2 to 27.3 Vdc Circuit capacitance 003 pF, max. Circuit resistance 13 ohms, max. Switch inputs Quantity: 5 End-of-line resistor: 4.7 k ohms ½ W Relay outputs Quantity: 9 Type: Common Style: Form C Contact rating 30 Vdc at 1 A (resistive load) Standby Current - 53 mA Alarm Current 114 mA - Operating environment Temperature: 0 to 49 °C (32 to 120 °F); Humidity: 0 to 93% RH, noncondensing at 32 °C (90 °F) S Page of 8 DATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 D4 0.0 01 hhi II 0 Dimensions !M1. bTf 3 D4 Five- 19.5 in 3.75 in 9.13 in 10.5 in 14.23 in zone (49.5 cm) (9.5 cm) (23.2 cm) (26.67 cm) (36.14 cm) Ten- 30 in 3.75 in 7.75 in 21.27 in 15.0 in zone (76.2 cm) (9.5 cm) (19.7 cm) (54.0 cm) (38.1 cm) Add 1½ inches (3.81 cm) to Dl and 05 dimensions for trim kit Control Panel Specifications CóntroIPanels , Fx-5RD 7 Initiating Device Circuits - IDCs (Available combinations shown at right) Class B 10 8 6 4 2 0 5 3 1 Class A 0 1 2 3 4 0 1 2 Notification Appliance Circuits - NACs (Available combinations showr at right) Class B 4 2 2 0 5 EE 2 0 Class A 0 1 1 E2 0 1 Power Supply 7.5 amps total 4.25 amps total NAC Voltage Rating 24 Vfwr Maximum NAC current 2.0 amps each, 7.0 amps total 2.0 amps each. 3.5 amps total AC Input 120 Vac 60 Hz... 230 Vac 50/601-lz... 2.2 amps - 1.1 amps 1.25 amps 0.6 amps Base Panel Current Draw Standby... Alarm... 128 mA 242 mA 104 mA 224 mA Pan& Battery Charge Capacity (sealed lead acid onm Up to two 24 Ph batteries, 18 Ph in cabinet Up to 24 Ph, 10 Ah max in cabinet * Auxiliary Current 0.5 amps max. May be programmed as resettable. Auxiliary Output 24 Vdc regulated lDC Alarm Current 3.0 mA (Consult detector compatibility list p/n 3101019-EN for maximum detectors per circuit) IDC Circuit Maximum loop resistance: 26 Ohms; Maximum loop capacitance: 0.03 tJF lDC Operating Voltage 16.9 to 29 Vdc UL Detector ID 100 Alarm Contact (normally open Form C) 30 Vdc @ 1 A (resistive load) Trouble Contact (Form C) 30 Vdc @ 1 A (resistive load) Supervisory Contact (normally open Form C) . 30 Vdc @ 1 A (resistive load) Operating Environment Temperature: 32 - 1200 F (0- 49° C); Humidity: 5 - 93% RH, non-condensing Terminals (wire gauge) . 18- 12 AWG (0.75 mm2 -2.5 mm2) Asynchronous Serial Communications Maximum resistance: 13 Ohms; Maximum capacitance: 0.03 pF Agency Listings . UL864 (53000), ULC-S527, CSFM, FDNY If larger batteries are required, use an external battery cabinet. ______________________ Receivers Supports two receivers with two phone numbers each Communications Protocol Contact ID (SIA DC-OS), 4/2 (SIA DC-02 P3) Programming Front panel controls or PC with appropriate software Telephone line connection Two RJ31X (plug-to-plug) cords supplied with DACT Telephone lines Two or one loop start lines on the public switched telephone network. Pulse or DTMF. Telephone wall connector RJ31X/CA31X equiv. or RJ38X/CA38X equiv. Communications Compliance Industry Canada CS-03; FCC/CFR 47 Parts 15 & 68; NFPA 72; UL 864; ULC S527 Operating Environment Temperature: 32-120° F (0-49° C); Humidity: 93% RH, non-condensing Current requirements Standby: 65 mA; Alarm: 107 mA Agency Listings UL864 (S3000), CSFM, FDNY Page 6 of 8 DATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 Ordering Information Part Description Number Control Panels Ship Wt. lb. Conventional Fire Alarm Control Panel, Red - 10 Class B lDCs and 4 Class B NACs, 7.OA NAC power, (Pairs of FX-10RD lDCs and NACs convertible to single Class A circuits), upload/download DACT/modem, 120VAC power source, 30.5 (13.8) 24VDC output Conventional Fire Alarm Control Panel, Red -5 Class B lDCs and 2 Class B NACs, 3.5A NAC power, (Pairs of lDCs FX-5RD and NACs convertible to single Class A circuits), upload/download DACT/modem, 120VAC power source, 24VDC 24.4 (11.1) F-TR1M35R Semi-flush trim ring for FX-5RD 1.7 (0.8) F-TRIM10R Semi-flush trim ring for FX-10RD 2.2 (1.0) Note: remove 'D in model number to order panel without the upload/download dialer in the panel Related Items F-XTR120 Expander Transformer, 120 Vac - For FX-10 only 4.0 (1.8) EOL3 6-1 1 Required UL listed End of Line Resistors - One 3.6K Ohm and one 1.1K Ohm. One required for each IDC configured as combination waterflow and supervisory. 0.1 (0.5 EOL-P1 Required ULC listed End of Line Resistor Plate - includes one 1.1K, 3.61K and 4.71K Ohm resistor 1.0 (0.5) 'Off Premises Communications F-DACT Upload/dowload digital Communicator/modem/LCD module (Mounts in control panel) 1.0 (0.5) CTM City Tie Module (Requires 4" square or 2-gang North American electrical box) 1.0 (0.5) RPM Reverse Polarity Module (Requires MFC-A or other listed fire alarm enclosure) 3.0 (1.4) Remote Annunciation FSRSI Remote System Indicator - Includes LEDs for display of Power, Alarm, Supervisory, Trouble and Ground Fault, trouble sounder and silence/lamp test switch. Single gang trim plate included, multi-gang plates ordered separately. Mounts in a single or multi-gang North American electrical box. 0.3 (0.1) FSRZI-A Remote Zone Indicator - Includes red LEDs for five lDCs. Single gang trim plate included, multi-gang plates ordered separately. Mounts in single or multi-gang North American electrical box. 0.3(0.1) . FSRZI-SA Remote Zone Indicator- Includes LEDs for five lDCs. Single gang trim plate included, multi-gang plates ordered separately. Mounts in single or multi-gang North American electrical box. Jumper selected Alarm (red) or Supervisory (amber) indications. 0.3 (0.1) FSAT1 Annunciator Trim Plate, 1 gang 0.1 (0.05) FSAT2 Annunciator Trim Plate, 2 gang 0.1 (0.05) FSAT3 Annunciator Trim Plate, 3 gang 0.1 (0.05) FSAT4 Annunciator Trim Plate, 4 gang 0.1 (0.05) FSRA1 0 Single Unit 10 zone remote annunciator for FX-10 K-FSRA10C Single Unit 10 zone remote annunciator for FX-10 (with common controls) K. FSUIM Common Function Graphic Driver/Interface - 9 relays and 5 switch inputs for common system indicators and controls Remote Relay Module FSRRM24 Remote Relay Module - Five Form C relays. Configurable for IDCs 1-5, or 6-10, or common system indications or 0.4 (0.2) matrix mode-Requires MFC-A or other listed fire alarm enclosure. . FSRRM-S11 11" Mounting track. Holds up to two FSRRM24s. 0.4 (0.2) Accessories MFC-A Multi-function Cabinet (fire alarm accessory enclosure) 7.0 (3.2) Page 7of8 DATA SHEET K850050126 Not to be used for installation purposes. Issue 1 2 Kid de wm.(i.s Irrvn4 -- Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: Kic.de,com/EnaineeredSvstems Kidde is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 © 2016 United Technologies Corporation. All rights reserved. Page 8 of 8 DATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 I S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM' 0 LISTING SERVICE LISTING No. 7165-1657:0102 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 United States Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com DESIGN: Models FireShield series FS302x, FS502x, FS1004x, *Models FireShield Plus FSP302x, FSP502x, FSP1004x, *Models FireworX series FX-3x, FX-5x, FX-10x and *Models FSC- series E-FSC302x, E-FSC502x, E-FSC1004x fire alarm control units. The suffix 'x may include any of the following alpha and/or numbers: G, R, G-2, GF, GD, RD, GC or *F. Models FSDACT and *F..DACT digital alarm communicator transmitter. Local, auxiliary, central station, remote station, automatic, manual, waterfiow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. *This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly 7165-1591:102, 7165-1501:129 7-29-10 ma :.. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division I S 9 0 © TELGUARD TG=7FS LTE-A P/N:TG7LAF01 CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS t COMMERCIAL FIRE PRODUCT FEATURES Certified for use on the AT&T LTE network for long, sunset- free installation. 1- Meets UL 864 requirements for sole, primary or backup path communications. 1- Minimizes false alarms by providing dual paths for self-tests. I- Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LIE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2016 Edition of NFPA 72, the TG-7FS LIE-A can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LIE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-A because of the new sixty minute supervision mode. The TG-7FS LIE-A can also be installed as a-backup path and upgraded to sole path at a later date. Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories ACID 12, ACID 35, ACID 50, ACID 100: 12/35/50/100 feet of low loss, high performance cable. HGDL-0: High gain directional antenna. EXDL-0: External antenna. ri LJ UL Listings Commercial Fire 864 control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected------ burglar alarm units and systems 1610 • central station burglar alarm units; Line security servcies Residential 985 Household fire warning systems 1023 Household burglar alarm systems ULC Listings S545 • Canadian household fire warning systems S304 • Canadian commercial burglary alarm systems C0123 • Canadian household burglary alarm systems For the most Current product specifications and ()L Listings visit www.Telguard.com. S TG=7FS LTE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD Telguard, a Division of Telular corporation • 3225 Cumberland Blvd SE • Suite 300 Atlanta, GA 30339 USA 800-229-2326, Option 5 www.Telguard.com copyright t2017 Telular corporation • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Models TG7LM02, TG7LA001, TG7LAA01, TG7LA002, TG7LAF01, TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF01, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DAd. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 11-27-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Models Available Single-circuit Models 5601P 135°F Fixed Temperature / Rate-of-Rise 5602 194°F Fixed Temperature / Rate-of-Rise 5603 135°F Fixed Temperature 5604 194°F Fixed Temperature Dual-circuit Models 5621 135°F Fixed Temperature / Rate-of-Rise 5622 194°F Fixed Temperature / Rate-of-Rise 5623 135°F Fixed Temperature 5624 194°F Fixed Temperature S Product Overview Multiple configurations available to satisfy a broad range of installations: Single- and dual-circuit models Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing available for residential installations (model 5601P) Easy to use terminal screws that provide a more positive wiring connection A broader range of back box mounting options: Single gang 3.5" and 4" Octagonal 4" square with square to round plaster ring Reversible mounting bracket for flush and surface mount installations ®MEA LISTED APPROVED approved S2101 3016008 199-03-8 7270-1209:227 System Sensor's 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit mod- els are offered, each available for low- and high-temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activa- tion. The ROR element of the fixed/ROR models is restorable, to accommodate field-testing the unit. Installation flexibility. To satisfy a variety of installations, the 5600 series easily mounts to single-gang and octagonal back boxes. These models also accommodate four-square back boxes, when used with a square to round plaster ring. The mounting bracket is reversible to allow for flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in degrees Fahrenheit and Celsius. Fixed temperature models are identified "FX", while combination fixed/rate-of-rise units are marked "FXJROR' The 5600 series also provides a post-activation indicator in the form of a collector. Once the detector has been activated, the collector drops from the unit, to easily identify the specific unit in alarm. Engineering Specification Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally .open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed tem- perature thermal sensor, or a combination fixed temperature/rate-ot-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mount- ing to 3'/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connec- tions shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combina- tion fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Electrical Specifications Operating Voltage / Contact Ratings 6 - 1.25 VAC / 3A 6 - 28VDC / 1A 125VDC / O.3A 250VDC / 0.1A Physical Specifications Maximum Installation Temperature Alarm Temperature Rate-of-Rise Threshold 5601P, 5603. 5621, and 5623: 100°F (38°C) 5601P, 5603, 5621, and 5623: 135°F (57°C) 15°F (8.3°C) rise per minute 5602, 5604, 5622, and 5624: 150°F (656°C) 5602, 5604, 5622, and 5624: 194°F (90°C) (models 5601P, 5602, 5621, and 5622 only) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Input Terminals 14-22 AWG Weight 6 oz. (170 grams) Mounting 31h-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Ordering Information Model Circuit Identification Method on Exterior Temperature Rating Activation UL Protected spacing -10 Foot Ceiling* 5601P Single None 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature . 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C)______ -Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. S U - 5601P 5602, 5622 5603, 5623 5604, 5624 5621 System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor - Far East System Sensor - India Ohio Avenue Ph: 905.812.0767 Ph: 86.29.8832.0119 Ph: 85.22.191.9003 Ph: 91.124.237.1770 x.2700 •3825 St. Charles, IL 60174 Fx: 905.812.0771 Fx: 86.29.8832.5119 Fx: 85.22.736.6580 Fx: 91.124.237.3118 Ph: 800/SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor - Australia System Sensor - Russia Fx: 630/377-6495 Ph: 44.1403.891920 Ph: 65.6273.2230 Ph: 613.54.281.142 Ph: 70.95.937.7982 www.systemsensor.com Fx: 44.1403.891921 Fx: 65.6273.2610 Fx: 613.54.281.172 Es: 70.95.937.7983 02005 System Sensor. The company reserves the right to change product specifications without notice. A05.0351-001.3/05.#1402 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM n LISTING SERVICE LISTING No. 7270-1653:0167 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: System Sensor Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models 5601 5601 P, 5602, 5621, and 5622 combination fixed-temperature and rate-of-rise type and Models 5603, 5604, 5623, and 5624 fixed-temperature mechanical heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Models 5601, 5601P, 5603, 5621, & 5623 have a fixed temperature of 135°F. Models 5602, 5604, 5622, & 5624 have a fixed temperature of 194°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, temperature/electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details and UL directory for dimensions. NOTE: Formerly 7270-1209:227 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering the test results and/or other data but does not make an independent verification of any claims. staff has reviewed This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division