Loading...
HomeMy WebLinkAbout2742 STATE ST; 103; FPC2021-0023; PermitEM PERMIT REPORT 4ity of Cailsba'd Print Date: 05/11/2021 Job Address: 2742 STATE ST, # 103, CARLSBAD, CA 92008-1628 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2031811900 Track #: Valuation: $154,357.20 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2021-0023 Status: Closed - Finaled Applied: 02/16/2021 Issued: Finaled Close Out: 05/11/2021 Inspector: Final Inspection: Project Title: Description: LOFTY COFFEE -FIRE ALARM TI (NEW NOTIFICATION APPLIANCES, ADDRESSABLE, 4 DEVICES) Applicant: FPContractor: JJJ ENTERPRISES JJJ ENTERPRISES MARIO AGUERO MARIO AGUERO 115 MARKET PL 115 MARKET PL ESCONDIDO, CA 92029-1353-SAN DIEGO ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 x209 (760) 747-3050 x209 FEE AMOUNT FIRE Reinspection (per inspection) $193.00 FIRE TI Fire Alarm System $620.00 Total Fees: $813.00 Total Payments To Date: $813.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov mn ENCLU ~ I FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS LOFTY COFFEE TENANAT IMPROVEMENT 2742 STATE STREET, SUITE 103 CARLSBAD, CA 92008 FIRE ALARM SYSTEM MATERIAL DATA SHEETS FIRE ALARM SYSTEM BILL OF MATERIALS NOTIFIER NMM-100P ADDRESSABLE MODULES CSFM# 7300-0028:0230 SYSTEM SENSOR PC2WL, SCWL, P2RL - CEILING & WALL MOUNTED HORN/STROBE & STROBE CSFM# 7135-1653:0503, 7125-1653:0504 /, I "1• Monitor Modules NMM-1 00(A), NMM.1 OOP(A), NZM-1 00(A), and NDM.100(A) for FireWarden Series Four different monitor modules are available for Notifier's FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-con- tact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-IOOP(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTM is a communication protocol that greatly increases the speed of communication between analog intel- ligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new infor- mation, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. NMM-100(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 99 on FireWarden-100- 2, 01 - 50 on FireWarden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (lDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- open dry-contact alarm activation devices. May also be used DN-6999:E NOTIFIER® hi AA/40 — n'pp aaa'a. Intelligent Addressable Devices NMM-100(A) (Type H) to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. NMM-100(A) OPERATION Each NMM-10C(A) uses one of the available module addresses on ar SLC loop, It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (DC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady On alarm (subject to current limitations on the loop). NMM-100A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IOC Voltage: 11 Volts. EOL resistance:.47K Ohms. Temperature range: 32"F to 120"F (0"C to 49"C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NMM-100PA) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. DN-6999:E • 07/30/2015— Page 1 0t4 Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address': 01-99 on FireWarden-100-2, 01 - 50 on FireWarden-50. 1415 0 1 ADDRESS 0 1 12/ 11 J4 1 LOOP 10 5 TENS ONES Ii.- II O Lij QIU ( - I-•- ujll r —ii SO ci —.i i 4::: ..cn The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-IOOP(A) is intended for use in intelli- gent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two- wire initiating device circuit for normally-open-contact fire alarm and security devices. NMM-100P(A) NMM-IOOP(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. NMM-IOOP(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). NMM-IOOP(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. NZM-100(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address:, 01 —99 on FireWarden- 100-2, 01 —50 on FireWarden-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two-wire conventional smoke detectors. It trans- mits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style 0 application. NZM-100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals TIO and Til): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. Page 2014— ON-6999:E • 07/30/2015 NDM-100(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class 8) /DC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. NDM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and '27". NOTE: "Ones" addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and reg- ulations. These modules are intended for power-limited wir- ing only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635. ULC: S635. FM Approved. ° CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100); 7300-0028:0237 (NDM-100). MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100). Product Line Information NOTE: "A" suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM-IOOP(A): Monitor module, miniature. NZM-100(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. DN-6999:E • 07/30/2015 - Page 3 of 4 Notifier® and FireWarden® are registered trademarks and LiteSpeedTM and FireWatchlM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I So 9001 We try to keep our product information up-to-date and accurate. 1 1 We cannot cover all specific applications or anticipate all requirements. ENINMINS All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6999:E •07/3012015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0230 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules; and *NzM1006 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7300-0075:0185' 08-23-11 rev. mt TI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division SYSTEM SENSOR Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15. 30, 75, 95, 115, 150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only Agency Listings SIGNALING - LISTED APPROVED I. S5512 FM approVed aecept Fl25•165.OSO4 S4011 for.ALERT rroeIs 7133-1653:e03 305736T The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws anD modern aesthetics. With white and red plastic housings, wall and celing mountng options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceilingmount strobes and horn strobes include a variety of features that increase their application versatility while simplifying "istallation. All devices feature a plug-in design with minimal intrusici- into the ba:k box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate 'so installers can mount them to a wide array of back boxes. With an onboard shoring spring, installers can test wiring continuity before the device is installed. Installers can also easily adept devices 10 a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volurle selections. L-Series Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for lire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage . Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) InputTerminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 rnrn high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P. 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AV0586800 UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A . 158 191 150 N/A 189 228 177 N/A 226 264 DC Input 8-17.5 Volts 15cd 30cd 16-33 Volts 15cd 30cd 75çd 95cd 11 5c 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1KTemporal High 111 164 69 94 147 163 184 229 257 3.1KTemporal Low 103 . 163 54 88 143 155 185 212 252 3.1K Non-Temporal High iii 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 115cd 150cd 177c Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3. 1 K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low . 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data jJ.]flLlaI.I Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 '7 ' 3.1 KHz Non-Temporal High 84 ' 89 89 8 3.1 KHz Non-Temporal Low • 77 83 83 " AVIDS68OO L-Series Dimensions 2.47 1.37 "— 2.50 —'- II Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire. Horn Strobe, White Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White @2017 Svstom Sense, 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject Lo change wio tic. Visit systensns.com SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 ''CUflIOdCI Ina On; udOthOatesoes,on oftn,scIaashoet 5y5ijj : . SEM,SORL Indoor Selectable , 1 Output Horns, Strobes, and '- Horn Strobes for t Wall Applications System Sensor L-Series audible visible notification ."- 1, products are rich with features guaranteed to cut r installation times and maximize profits with lower current draw and modern aesthetics. ' —."-- Features Updated Modern Aesthetics - The System Sensor L-Series offers the most versatile and Small profile -devices for Horns and Horn Strobes - easy-to-use line cf horns, strobes, and horn strobes in the industry Plug-in design with minimal intrusion into the back box with lower current draws and modern-aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, Tamper-resistant construction and FUEGO-printed devices. System Sensor L-Se:es can Automatic selection of 12- or 24-volt operation at 15 and 30 meet virtually any application'requirement. candela Field-selectable candela settings on wall units: The L-Series line of wall-mount horns, strobes, arid horn strobes 15. 0, 75, 95, 110, 135, and 185 •, '- include a variety of features that increase their application versatilty Horn rated at 88+ dBA at 16 volts ' . ' while simplifying installation. All devices feature pUg-in designs with minimal intrusion into the back box, making iretallations fast Rotary switch for horn tone and two volume selections and foolproof whie virtually eliminating costly and time-consuming o Mounting plate for all standard and all compact wall units 'ground faults Mounting plate shorting spring check wiring continuity before , device installation . •' To further simplify installation and protect devices from constructicn Electrically.compatible with legacy SliectrAlert and SpectrAlert damage, the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring, so installers can test wiring Compatible with MDL3 sync module , continuity before The device is installed. - Strobes and.Horn Strobes listed for.wall mounting only, Installers can also easily adapt devices to a suit a wide range Horns listed for wall or ceiling use of application requirements using field-selectable candela set:ings, automatic selection of 12- or 24-volt operation, and a rotary switcf- for horn tones with two volume selections. - Agency Listings SIGNALING, OQfl LISTED - -,-------- - - - - - - . - S5512 FM oporoved exc,eo/ 7125-165304 - - - - S4011 for ALERT r000elo "135-1653:05,13 - - - - 30s7382, 30L?072 - -- - AVCESR5-05 • 2122'2016• Page 1 L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 1 /2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync'Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110. 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync'Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/ic x 21/e-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage . Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 1210 18AWG Wall-Mount Dimensions (including lens) 5.6"L x 4,7"W x 1.91'D (143 mm Lx 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" L x 3.46' W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6'i x 4.7"W x 1.25"D (143 mm Lx 119 mm x 32 mm D) Compact Horn Dimensions 5.25" Lx 3.45" W x 1.25" D (133 mm Lx 88 mm W x 32 mm D) Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 Cd and 30 cd. AVDS865.05 • 2/2212018 - Page 2 Sound Pattern . dB 8-17.5 Volts DC 16-33 Volts DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High . 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded Hiah 42 43 54 UL Current Draw Data 8-17.5 Volts 16-33 Volts Candela • DC . DC FWR Candela 15 88 43 60 Range 30 143 •63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 DC Input 8-17.5 Volts 15cd 30cd 16-33 Volts 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 . 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 . 51 . 71 119' 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.lK Temporal Low 91 154 45 66 112 133 160 . 185 235 3.1K Non-Temporal High 99 162 69 . 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts l5cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 83 107 156. 177 198 234 . 287 Temporal Low 68 91 145 . .165 185 223 271 Non-Temporal High .. 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197. . 235 283 3.1K Temporal High .81 . 105 155 177 196 . 234 284 . 3.1K Temporal Low . 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 .. 131 . 177 . 204 230 264 326 3.1K Non-Temporal Low . 77 .102 156 177 199 . 234 291 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR Temporal . High 84 89 89 2 Temporal . Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low . 76 . 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 . 82 7 3:1 KHz Non-Temporal High 84 . 89 89 8 3.1 KHz Non-Temporal 'Low 77 83 83 9* . . Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes. Temporal coding must he provided by the NAC. If the NAC voltage is held constant, the horn output remains constantly. on. . . AVDSS65-05 • 212a'2018 • Page 3 L 14 32 mm AOE'49-00 Horn A0554-01 Wall Surface Mount Back Box SBBRL/SBBWL 4.70' (11.94 cm) ---------- 1.91" (4.85 cm) A . j'1fl (3.18 mm) 5.67" III (1cm) Lj Strobe, Horn Strobe A0550-00 L-Series Dimensions 32 met A0548.00 A054 7.00 A055700 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL L-Series Ordering Information Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO P4RL 4-Wire, Horn Strobe, Red P4WL 4-Wire, Horn Strobe, White Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Horns* HRL Horn, Red HWL* Horn, White HGRL* Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Walt Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover). All -SP models have FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. 'Horn-only models are listed for wall or ceiling use. 5 4#ç77I7 3825 Ohio Avenue • St. Charles, IL 60174 .02OI8SYSteO'SeOSO ., Phone' 800-SENSOR2 • Fax . 630-377-6495 SpéCCO'iOfl$ Subiect tOCh4TTO withO,nOtic. Viol syslontse,'so, COO' ENsoR TO' current product inforntation, irciuding the iCIest version of this Clara ShOL www.systemsensor.com AVDS5-05 • 212z'2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL idommilam - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listees printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sissonhoneyweII.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-82, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walllrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 91 Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division SYSTEM RECORD OF COMPLETION This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data, or calculations as necessary to provide a complete record. Form Completion Date: Supplemental Pages Attached: n/a PROPERTY INFORMATION Name of property: Lofty Coffee - Fire Alarm TI Address: 2742-2752 State Street, Carlsbad, CA 92008 Description of property: Retail/Office Name of property representative: Address: Phone: Fax: E-mail: INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATION Installation contractor: JJJ ENTERPRISES Address: 115 MARKET PL, ESCONDIDO, CA 92029 Phone: 760-747-3050 Fax: 760-747-7561 E-mail: INFO@JJJENT.COM Service organization: SAME AS ABOVE Address: Phone: Fax: E-mail: Testing organization: SAME AS ABOVE Address: Phone: Fax: E-mail: Effective date for test and inspection contract: n/a Monitoring organization: GMS Address: 1127 LOMA AVE. LONG BEACH, CA 90804 Phone: 888-467-1119 Fax: E-mail: Account number: J71035 Phone line 1: Means of transmission: Cell Entity to which alarms are retransmitted: DOCUMENTATION On-site location of the required record documents and site-specific software: DESCRIPTION OF SYSTEM OR SERVICE Phone line 2: Phone: NEXT TO FACP This is a: D New system 0 Modification to existing system Permit number: FPC-2021 -0004 NFPA 72 edition: 2019 4.1 Control Unit Manufacturer: NOTIFIER Model number: NFW-1 00x 4.2 Software and Firmware Firmware revision number: 26 4.3 Alarm Verification This system does not incorporate alarm verification. Number of devices subject to alarm verification: N/A Alarm verification set for seconds (p.1 of 3) .1 SYSTEM RECORD OF COMPLETION (continued) SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120 VAC Overcurrent protection: Type: CIRCUIT BREAKER Branch circuit disconnecting means location: HOUSE PANEL 5.1.2 Secondary Power Type of secondary power: BATTERIES Location, if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode (hours): 24 HOURS 5.2 Control Unit This system does not have power extender panels 0 Power extender panels are listed on supplementary sheet A CIRCUITS AND PATHWAYS Control panel amps: 5 AMPS Amps: 20 Number: HM-37 In alarm mode (minutes): 5 MINUTES Pathway Type Dual Media Pathway Separate Pathway Class Survivability Level Signaling Line N/A N/A B I Device Power N/A N/A B 1 Initiating Device N/A N/A B 1 Notification Appliance N/A N/A B Other (specify): N/A N/A N/A N/A REMOTE ANNUNCIATORS Location ANN-80 KEYPAD (EXISTING) MAIN ENTRY OF BOTH BUILDING INITIATING DEVICES Type Quantity Addressable or Conventional Alarm or Supervisory Sensing Technology Manual Pull Stations 1 (EXIST) ADDRESSABLE ALARM DRY CONTACT Smoke Detectors 5 (EXIST) ADDRESSABLE ALARM/SUPV PHOTOELECTRIC Duct Smoke Detectors 8 (exist) 2 new CONV W/ADDR MOD SUPV PHOTOELECTRIC Heat Detectors 1 (EXIST) ADDRESSABLE ALARM HEAT Gas Detectors 0 N/A N/A N/A Waterfiow Switches 1 (EXIST) N/A N/A DRY CONTACT Tamper Switches 2 (EXIST) ADDRESSABLE SUPV DRY CONTACT (p.2 of 3) SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible 0 N/A Visible 1 (NEW) SYSTEM SENSOR STROBE Combination Audible and Visible 2 (NEW) SYSTEM SENSOR STROBE HORN 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices N/A HVAC Shutdown 2 Fire/Smoke Dampers N/A Door Unlocking N/A Elevator Recall EXISTING Elevator Shunt Trip EXISTING Ansul/Hood 1 INTERCONNECTED SYSTEMS This system does not have interconnected systems. D Interconnected systems are listed on supplementary sheet CERTIFICATION AND APPROVALS 12.1 System Installation Co racto This syste s spec i been lIed according to all NFPA standards cited herein. Sign ted name: VINNIE BRUZZI Date: / Organi.... Title: FORMAN Phone: 760-747-3050 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: SAME AS ABOVE Printed name: Date: Organization: Title: Phone: 12.3 Acceptance Test Date and time of acceptance test: Installing contractor representative: Jim McKinley Testing contractor representative: Jim McKinley ( ACCEPTANCE TESTING Property representative: AHJ representative: (p. 3 of 3)