Loading...
HomeMy WebLinkAbout2742 STATE ST; 103; FPC2021-0027; PermitPERMIT REPORT rf ity of Carlsbad Print Date: 05/12/2021 Job Address: 2742 STATE ST, # 103, CARLSBAD, CA 92008-1628 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2031811900 Track #: Valuation: $154,357.20 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Project Title: Description: LOFTY COFFEE CO -SPRINKLER TI (10 HEADS) Permit No: FPC2021-0027 Status: Closed - Finaled Applied: 03/04/2021 Issued: 03/16/2021 Finaled Close Out: 05/12/2021 Inspector: Final Inspection: Applicant: - FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 . (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov OITA14 FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS LOFTY COFFEE 2742 STATE STREET, SUITE 103 CARLSBAD, CA 92008 Page 1 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 'iIi(iI1 SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth coiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a ow- profile cover assembly that provides up to %" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is cULus Listed as indicated In the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 WARNING: Cancer and Reproductive Hann. www.P65Wamings.ca.gov VdS Approved: Certificate G4080021 Vmd LPCB Approved: Certificate number 096e112 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249 cj CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate 0832-MED-1003 Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMethc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-051000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 2 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 41I II(II1i SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-051000 Cover Adapter: Cold Rolled Steel UNS-G1 0080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 or Stainless Steel UNS-S30400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 - 13503A for Brass finish and 13503JN for ENT finish. VK463 - HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 "F (68 "C) = B, 175 "F (79 "C) = D, 200 "F (93 "C) = E For example, sprinkler VK463 with a 155 °F (68 "C) temperature rating = 13667AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 °F (57 "C) UL (139 "F (59 "C) FM and LPCB) = A, 165 "F (74 "C) = C For example, cover 13504 with a Polished Chrome finish and a 165 "F (74 "C) temperature rating = 13504FC. Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 "F (57 "C) UL (139 "F (59 "C) FM and LPCB) = A, 165 "F (74 "C) = C For example, cover 21876 with a 165 "F (74 "C) temperature rating = 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135 "F (57 "C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Wrench Part No. 14047W/B (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a /2" ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731 A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 3of7 MIRAGE® STANDARD AND QR CONCEALED PENDENT "sJ IIII1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384.5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE TEMPERATURE RATINGSAND1llFI:l* Sprinkler Sprinkler Maximum Nominal Ambient Temperature Rating of Cover - Cover Plate Large Cover Square Cover Temperature Temperature Ceiling Assembly (Required) Base Part Plate Base Part Plate Base Part Bulb Color Classification Rating' Temperature Number' Number' Number3 Ordinary 155 °F (68° C) 100 °F (38 °C) 135°F (57 °C) cULus 13504 or 218765 13642 or 218755 15394 Red 139 °F (59 °C) FM and LPCB _ ____________ Intermediate 175 °F (79° C) 150 °F (65° C) 165 °F (74 °C) 113504 or 218765 1 13642 or 2187551 15394 1 Yellow Intermediate 1 200 °F (93° C) 150 °F (65° C) 165 °F (74 °C) 113504 or 21876 13642 or 2187551 15394 Green Cover Plate Finishes': Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings4: ENT Footnotes 'The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. (/$P cUs7b4, -4. 0 C) N1KIN I All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers Figure 2: Square Cover Assembly 15394 Form No. F_103005 18.10.11 Rev 18.2.P65 Page 4 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT 'III(jIt1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269.818.1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com - art 1(UL) Approval Ch Sprinkler Temperature Rakng Cover Plate Temperature Rating I Mirages Concealed Pendent Sprinklers VK462 and VK46 AWl. Cover Plate Finish KEY Thread Nominal Maximum Listings and Approvals4 Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria) Base Part No.' Inch mm U.S. metric' Pressure cULus5 NYC VdS7 F LPCB (( f 12 [ ( Standard Response Applications 13503A VK462 1/2" - 5.6 80.6 175 psi (12 bar) - -- AY1,CZ1 AY1,BZ1 AY1, CZ18 AY3 - 19785A VK462 1/2" - 5.6 80.6 175 psi (12 bar) - - - -- AY2, CZ2 21356A VK462 - 15 5.6 80.6 175 psi (12 bar) - -- - - - - AY2, CZ2 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1, AV1, BX16 - - -- AY3 -- AS3, BT3 13503JN'1 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1,AV1, BX16 - - -- - -- __________ AS3, BT3 13667A VK463 1/2" 15 56 80.6 1 250 psi (17.2 bar)3 I AV1, BX1 AV1, BX16 - -- - - - Cover Plate Assembly Temperature Ratings19 Sprinkler Temperature S - 135°F (57 °C) cover 21876 or 21875 (large diameter) Cover Plate Assembly Finishes10 Ratings T - 165 OF (74 °C) cover 21876 or 21875 (large diameter) 1 - Polished Chrome, Brushed Chrome, Bright Brass, Antique A- 155°F (68 °C) OF °C) V - 135 (57 cULus Listed cover 13504, 13642 (large Brass, Brushed Brass, Brushed Copper, Painted White, diameter), or 15394 (square cover plate) B - 175 OF (79 °C) and 200 OF x - 165 OF (74 °C) cover 13504, or 13642 (large diameter) Painted Ivory, or Painted Black (93 °C) Y- 135 OF (57 °C) cover 13504 LPCB Approved as 139 OF 2 Brass C - 200 OF (93 °C) (59 °C) 3 Stainless Steel Z - 165°F (74 °C) cover 13504 Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1:1999 + A1:2001 + A2:2004 + A3:2006, Certificate G4080021. 8 CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD40249. The 135/139 OF cover has an orange label. The 165°F (74 °C) cover has a white label. '° Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11 cULus Listed as corrosion resistant. 12 IVIED Certified, Standard 12259-1, EC-certificate 0832-MED-1003. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 5 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT N41KJNG SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1) cULus Listing Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS ADoroval Requirements: The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. Follow installation guidelines of current standards, CEA4001VdS and EN 12845. These sprinklers can only be installed in LH and OH occupan- cies, except in 0H4. NOTES: Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: Prepare the sprinkler key. Remove the plastic cover. Hold the sprinkler with the wrench and fasten it. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 6 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) I — I —SprinklerTemperatureRating CoverplateTemperatureRahng I Mirages Standard Response concealed Pendent Sprinkler VK462 AW1+ Cover Plate Finish KEY Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum FM Approvals' Part No.' I I Water Working I (Refer also to Design Criteria below.) Inch mm I U.S. I meti1c2 I Pressure 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AWl, BX1,AY2, BZ2 Cover Plate Assembly Temperature Rating&4 Cover Plate Assembly Finishes' °F °C) Y - 139 (59 cover 21875 or 21876 Sprinkler Temperature Ratings z - 165 °F (74 °C) cover 21875 or 21876 1 - Polished Chrome, Brushed Chrome, Bright A - 155 °F (68 °C) W - 139 °F (59 °C) cover 13504, 13642 (large diameter), or Brass, Antique Brass, Brushed Brass, B -175°F (79 *C) and 200°F (93 °C) 15394 (square cover plate) Brushed Copper, Painted White, Painted X - 165 °F (74 °C) cover 13504, 13642 (large diameter), or Ivory, or Painted Black 15394 (square cover plate) 2 - Stainless Steel Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 Page 7 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT N11a I1G SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler and Adapter Assembly Protective cap - Sprinkler Wrench removed 0. ---- Part No. 14047WB** Step F Carefully slide the wrench sideways around the deflector and pins 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: t Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047WB** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise I to 1-1/2 turns beyond finger tight. Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 112" ratchet is required (Not available from Viking) kler arms Sprinkler wrench fla 1/2" (15 mm) NPT 2-9/16" (65 mm) EJ Maximum 2-1/16" (52 mm) Minimum 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13/16" (21 mm) below the sprinkler body. Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_103005 18.10.11 Rev 18.2.P65 Replaces Form No. F_103005 Rev 18.2 (Added P65 Warning.) Page 1 of 6 N411UNG4 MICROFAST® QUICK 11il:II[.q1..yIy RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera. ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV € FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 I-PCB Approved: Certificate 096e106 [~ WARNlNG Cap= and RepdijcUve fam CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 ji CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1 EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart I and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) .cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar) Approvals ONLY is 5 psi (0.35 bar). The minimum operating pressure for LPCB and CE Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F (57 °C) =A, 155°F (68 °C) = B, 175°F (79 °C) = D, 200°F (93 °C) = E, 286°F (141 °C) = G Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) Page 2 of 6 MICROFAST® QUICK J IF(IFSIG l:IIiu.yv RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W1B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfas& Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap - 40 Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 19.02.21 Rev 19.1 Page 3 of 6 NIKJNG4 MICROFAST® QUICK l:II[i..yIy RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient ' Classification Temperature Rating' Ceiling Temperature' Bulb Color u Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/ for recessed pendent sprinklers ** A 1/2" ratchet is requin (not available from Vikin Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 19.02.21 Rev 19.1 Page 4 of 6 MICROFASP QUICK 1II(II1G l:ll[.u.LIv RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Ternpera ure The Viking Mucrofast® Quick Response KEY Pendent Sprinkler VK302 Al i— Escutcheon (W appcobIe) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread d i• ze Nominal Overall Listings and Approvals' Part SIN K-Factor Length (Refer also to Design Criteria.) Number' style NPT BSP U.S. 'metric' Inches mm cULus4 VdS LPCB - 12979 VK302 Pendent 1/2" 15 mm 56 80.6 2-1/4 58 A1Z,131Y,D2,C2X Al A1Z,B1Y D1ZClY 0-1 19780 VK302 Pendent 1/2" -- 5.6 80.6 2-1/4 58 - -- -- - D3 - 21354 VK302 Pendent -- 15mm 5.6 80.6 2-1/4 58 - -- -- - - 03 NOTICE - rl:I lability (Contact Local Viking liJiflj 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X -- -- - - - 18021 VK302 Pendent 1/2" 15mm 5.6 80.6 2-1/4 58 AiX, B1Y Al AiX, BIY D1X, dY7 Dl - Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 OF (57 °C), 155 OF (68 °C), 175 OF 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 OF (93 °C), 286 OF (141 °C) Polyester56, Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B - 135 OF (57 °C), 155 OF (68 °C), 175 OF ter' .6 Y - Standard surface-mounted escutcheon or recessed with the Viking Micromatic® (79 °C), and 200°F (93 °C) 2- ENT5 Model E-1, E-2, or E-3 Recessed Escutcheon C - 155 OF (68 °C), 175 OF (79 °C), and 3 - Chrome Z - Standard surface-mounted escutcheon 200 OF (93 °C) D -155°F (68 °C), 175°F (79 °C), 200°F (93 °C), 286 °F (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. "Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. 1 CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-50021. MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA- UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Page 5of6 MICROFAST® QUICK l.l:ll[.qu'7M RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384.5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) -Temperature KEY The Viking Microfast° Quick Response Fin:sh Pendent Sprinkler VK302 A1X4- Escutcheon (if appcabte) Maximum 175 PSI (12 Bar) WWP Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' NPT .BSP u.s. 1 metric' Inches mm Number' Style (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 ]:!58 A1Z, B1Y, D2X, C2 NOTICE___ Product Belo!'ILimited Availability TlLocaY7l Viking Office) 06662B I VK302 Pendent j 1/2" I 15 mm 1 5.6 80.6 1 2-1/4 1 58 1 A1Z, B1Y, D2X, C2 18021 1 VK302 Pendent J 1/2" 1 15 mm 1 5.6 80.6 2-1/4 1 58 1 A1Z, B1Y Approved Temperature Ratings Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 CC), 200 °F X - Standard surface-mounted escutcheon or the (93 CC), 286 F (141 °C) Approved Finishes Viking Micromatic® Model E-1 Recessed B - 135 F (57 °C), 155 ¶ (68 SC), 175 F (79 °C), and 1 - Brass, Chrome, White Polyester4, Escutcheon 200 °F (93 C) and Black Polyester4 Y - Standard surface-mounted escutcheon or recessed C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT' with the Viking Micromatic Model E-1 or E-2 °F (141 °C) Recessed Escutcheon D - 155 °F (68 °C), 175 ¶ (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA- FM (Also refer to Approval Chart 2 above.) FM Aooroval Requirements: The Viking Microfast° Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Page 6 of 6 1H(II%1G MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" - 2-5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum NPT\ -- jk--44 (45 mm) Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon (54 4m4 Installed with a Model E-1 Recessed Escutcheon A.~:o _ (54 mm) - 1-1/8" (29 mm) 2" — (51 mm) Installed with a Model E-2 Thread-on Recessed Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 1-1/8" (29 mm) Mm. Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) Page 1 of 4 NI . . MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS ctJLus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. ,, WARHiNG Cww and Ra Han / • WWWFWW8fKqPALGW 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated SDrinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141 = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: -Part No. 21475M/B (available since 2017) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 18.10.11 Rev 17.1.P65 Replaces Form No. F_052114 Rev 17.1 (Added P65 Warning.) Page 2 of 4 \IK1 MICROFAST® QUICK I 4 .M 7 RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1 :AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature 2 Ordinary 135 °F (57 C) 100 °F (38 °C) Orange Ordinary 155°F(68C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 C) Yellow Intermediate 200 °F (93 C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap -..........___ Wrench Flat Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_052114 18.10.11 Rev 17.1.P65 Page 3 of 4 N II(iriG: MICROFAST® QUICK 4 l:II[.r..u.7..If RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) KEY Microfast® Quick Response Upright Sprinkler VK300 A14 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals SIN Number 1 NPT BSP U.S. metric2 Inches mm cULus VdS I LPCB NYC8 C 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, 132 -- -- See footnote 7. NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 06661B I VK300 1/2" 1 15 mm 1 5.6 I 80.6 1 2-3/16 56 I Al, 132 -- -- Isee footnote i.I - Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 1 - Brass, Chrome, White Polyester56, and Black Polyester5'6 °F 286 (141°C) 2 - ENT6 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 8 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA -UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 18.10.11 Rev 17.1.P65 Page 4 of 4 NlKING 4 MICROFAST® QUICK l:Il[.1.u.JM RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) I-e4V%-VV KEY Microfast® Quick Response ,,. Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm 12978 VK300 1/2° 15 mm 5.6 80.6 2-3/16 56 Al, B2 NOTICE - Product rn Limited Availability Local 1.JIll 06661B VK300 1 1/2" 1 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F (141°C) 1 White Polyester', and Black pBoI;ass ::;ehrome B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT6 Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Methc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Aooroval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus andlor NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F052114 18.10.11 Rev 17.1.P65 Replaces Form No. F_052114 Rev 17.1 (Added P65 Warning.) c®us LISTED <19> AVPI1OVII C;] 4 Q_ NFPA SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE SIZE (IN) O.D. (IN) ID. (IN) CRR** WEIGHTIFT WATER FILLED WEIGHT BUNDLE SIZE 1 1315 1.097 15.27 1.41 lbs/ft 1.820 91 1-114 1.660 1.442 - 9.91 -- ir 181I6s/f( 11 2518 - 61'i 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 J[ 2.64Ibs/ft 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lb9ft 5.893 30 3 iL 3500 ][ 3.260 334 II 44LbS/ft It 7,957 II 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE OLD. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1.315 1.049 1.00 1.68 lbs/ft 2,055 70 1-1(4 1 1660 1,380 11 100 ][2271bs/ft j{ 2918 ][ - Si 1-112 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 II 2.067 ][ 1.00 [ 3.66 lbs/ft )t 5.114 30 2-1/2' 2.875 2.468 1.00 5,80 lbs/ft 7.875 30 3* ][ 3.500 3.068 II 1,00 7.581bs/ft II 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 4On1avaiabfe in CaM G,an*teAZ Ccuion Re6stam Ratio pr latest UI Wrectaty Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from Indentations and projections from the end of the pipe to the groove. All loose paint, scale, dht chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ( For Additional Information Contact (800) 325-4467 - www.builmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkscn Road thestef1ekt MO Ceakl, MO lntWA Casa Grand AZ DatlTX Masur OH 63017 Buli Moose Tubes Schedule 10 and Schedule 40 are FM Approved and UL Listed (for IJ.S and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube'sr Schedule 10 and Schedule 40 pipes are hot dipped galvanized to rneetASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. Dull Moose lube's°Eddythread4Q ADVANTAGES OF BULL MOOSE TUBES EOOVTHPEAO 400 U is a lightweight replacement for .. Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. e Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers tower freight costs. Supplied with EDDY GUARD 1110 MIC preventative coating. EDDVTHREAD 40® SPECIFICATIONS NOMINAL PIPE 00. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR1 LB/FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-114 jI 1.650 1.418 j[ 1.00 j 2.070 11 2.754 A Si 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2.3?SJLZ.123JL 1.00 J[j 4.842 [ 30 Cortos1an ResLtane Ratio per latest UL Directory Listing r c®us LISTED Mo A, ONFSA NFPA PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's Instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 wwwbulImoosetube.com Or From Canada Call: (800) 882.4666 sales8buItmoosetube.com 1819 CIarkon Road thesterfield,MO Geratd.MO Kent WA CasaGrande,AZ Dailas,TX Masur0H 63017 Bull Moose Tube's* Eddylite is a lightwall threadable pipe manufactured in NPS 1 through 2". Eddylit& is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite is manufactured to meet the requirements of ASTM Al 35 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. ADVANTAGES OF BULL MOOSE TUBES EDDYLITE Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight dose to Schedule 30: compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CPR) NOMINAL STANDARD INSIDE UL Ut. WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER Ft FILLED SIZE 1 1.315 1,137 0.13 7.47 1.260 1.700 91 1-114 II 1660 ( 1.482 008 [ 479 )[ 1617 ][ 2364 61 1-112 1.900 1.712 0.12 4.53 1.967 2.965 61 2 _j[ 2.375 j[ 2.177 0.16 J1 4.31 11 2.617 II 4.230 II 37 ] *Cortosicn ReSIstanCe Ratio per latest UI. Directory Listing r c®us LISTED I APPItfNEO NFPA PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to Installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ( For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetubetom 'tD i 1819 Clarkson Road Chesterfield, MO Gerald. MO Kent,WA Cam GrandeAZ Dallas,TX ma" 0H eCKWAAW 63017 Dull Moose Tube's Eddy Fto ADVANTAGES OF BULL MOOSE TUBES EDDY FLOW Li is a specially engineered Certified to ASTM Al 35 and A795 Type E, Grade A. replacement for Schedule 10. FM approved for roll grooving and welding for use in wet systems. offering better flow characteristics UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well Lightweight - saves shipping costs and offers easier handling. as UL Listed (for U.S. and Canada) Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM'S & UL requirement for dry systems. As an added benefit, it is more Supplied with EDDY GUARD 110 MIC preventative coating. economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, NPS O.D. EDDY FLOW EDDY FLOWID WEIGHT WATER FILLED BUNDLE Eddy Flows' larger ID provides SIZE (IN) (IN) (ID) CRR PER FL Wt SIZE an opportunity for downsizing and further cost savings. I-It4 1.660 1.530 1.98 1.222 2,019 61 1.12 1,900 1.728 II 3.44 .11 1,844 - 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 [ 2.875 2.705 II 1.66 2.809 ft 5.299 II 30 3 3.500 3.334 1.00 3.361 7.144 19 - 41L 4.500 J1 4.310 j[ 1.00 II 4.968 ][ 11.290 J[ 19 (OrWSQfl Resistance Ratio per latest UL Directory Listing r ®S LISTED <19> I APP1tOVW NFPA PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ( For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 salesbullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gefald,MO Kent WA CasaGrandeAZ DaUaTX Wd" OH 63017 7 Dull Moose Tube's Ultra Eddy is ADVANTAGES OF DULL MOOSE TUBES ULTRA EDOV Li a versatile product that can be Certified to ASTM Al 35 and A795 Type E. Grade A. roll grooved, welded, and used with FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. UL listed (for U.S, and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight -saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule S approved roll grooved, welding and Pressflt Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy4l offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. ISIPS OLD. ULTRA ULTRA EDDYO WEIGHT WATER BUNDLE (IN) (IN) EDDY (ID) CRR*I PER Ft FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-14 1.660 - II 1.546 [ 1.40 1.107 1.920 61 1-112 1.900 1,786 1.11 1,274 2360 61 [2j 2.375 Jj 2.261 ][ 1.00 1.604 3.344 IL 37 1 * Ps.sflt is a RegisteedTradema,k of Vtctaulk company of America 'Cairosien Resistance Ratto per latest ULDrestoy Listing c®us LISTED <> APPROVED u ,4oN NFPA' PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paInt, scale, dIrt, chIn grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly; causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 salesbulImoosetube.com U 1819 Clarkson Road ChesterfieictMO Getatd,MO Kent WA CasaGnndeZ DaUas,TX Mur0H Pf" MCI MW 63011 NIPS (IN) 1 1-1/4 1-112 2 2-112 3 4 c®us LISTED APPfiOVU Ui] I4ONFSA NFP 0.D0 1.315 1.660 1.900 2.375 LD.(in) 1,201 1,546 1.786 2.261 ULTRA EDDY' EmptyWeight(iblft) 0.868 1.107 1,274 1.604 ter$ilIedWeightOb/ft) 1.359 1.920 2.360 3.344 C.R.R. 2.17 1.40 1.11 1.00 O.Dn) " • 1.660 1.900 1 2.375 2.875 3.500 4.500 ID(In) 1.530 t 1,728 2,203 2,705 3334 4310 EmplyWit(b/ft) 1,222 1.844 2,330 2.809 3361 1 4,968 EDDY FLOW' techd Weight (htft) 2,019 2.860 1 1,982 i 5299 7 144 1 11,290 C.R.R. 1.98 F? 3.44 2.78 1.66 1.00 1.00 0.D.(iIi) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1,a(in) 1.097 1,442 1.682 2.157 2435 3.260 4,260 SCHEDULE 10 Emptyit(Ib/ft 1.410 1.810 2.090 2.640 3.530 4.340 5.620 .ftteIIed Weight (Ihft) 1.820 2.518 3.053 4.223 5.893 7,957 11.796 C.R.R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 00 (ii) 1.315 1.660 1.900 2.375 D (in) 1137 i 1,482 1.712 2,177 EDDYLJTE' EmpyWe1gtt(Ib(ft) 1,260 1,617 1,967 2,617 l Water-Filled Weight (th/ft) 1.700 2.364 2965 4.230 MR. 013 008 012 016 I 0.D n) 1.295 1.650 1.900 2.375 : LD,n 1.083 1,418 1.645 2.123 EDDHRD Empty 'it Ob/ft) 1.461 2.070 2.547 3.308 400 'WatIkd Weight (Ib1ft) 1.860 2.754 3.468 4.842 C.R.R. 1.00 1.00 1.00 1.00 OD(in) 1.315 1,660 1,900 ' 2.375 2,875 3,500 4,500 LDn) 1049 I 1380 1,610 2,067 1 2,469 3068 4,026 S EDULE CH Empty iWçt (lb/fr) 1.680 2.270 2.120 ( 3.660 F 5.800 7,580 10,800 teiFllledWe,ghtØb/ft) 2055 2918 3602 5114 7875 10783 16.316 CRR ; .OQ) L 1-09_ 1.00 _L 1 _L _1.00 ; C For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales1bullmoosetube,Corn 1819 Clarkson Road chesterfiekiMO Gerald, MO IntWA CasaGrandeZ DallasTX Mast 0H su 63017 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE -- ULTRA EDDY 0.868 SCHEDULE 10 1.410 I EDDYUTE* 1,260 EDDYTh READ 4O ' 1.461 SCHEDULE40 1.680 - ULTRA EDDY' ::, 1.107 EDDY FLOW' 1,222 SCHEDULE 10 1.810 1-1/4 EDDYLP 1.617 EDDYTHREAD 40' - - 2.070 SCHEDULE 40 1 1270 ULTRA EDDY' 1.274 EDDY FLOW' 1.844 SCHEDULE 10 : 2.090 , - EDDYLITE' 1.967 EDDYTHREAD4O' 2,547 [ SCHEDULE 40 2.720 ULTRA EDDY 1.604 EDDY FLOW' 2.330 SCHEDULE 10 2.640 EDDYUTP 2.611 EDDYThREAD4O. 3.308 SCHEDULE 40 3.660 - EDDY FLOW' 2.809 2112 - SCHEDULE 10 3.530 SCHEDULE 40 5.800 EDDY FLOW' 3.361 3 -, SCHEDULE 10 4.340 - SCHEDULE 4Q* ': 7,580 EDDY FLOW' 4.968 4 SCHEDULE 10 5.620 - SCHEDULE 40* - 10.800 6 SCHEDULE 10 9.289 8 SCHEDULE 10 16.940 '0aIAaiFabH H Casa GzancH,AZ. 91 1.659 1,896 1,975 91 2,695 3,079 3,208 91 2,408 2,752 2,867 70 2,148 2,454 2,557 70 2.470 2.822 2,940 61 jj 1,418 H 1,621 11688 61 U 1,565 11 1,789 1,864 61 j 2,319 2,650 2,760 61 J1 2,071 1' 2,367 2,466 51 2,217 :-: 2,534 . 2,639 51 j 2,431 2,178 2,894 61 1,632 1,865 1,943 61 2,362 2,700 2,812 61 2,677 3.060 3,187 61 2.520 2,880 3,000 44 2,353 2,690 2,802 44 2513 2,872 2,992 37 1,246 U 1,424 ' 1,484 37 1,810 2,069 2.155 37 2,051 2.344 2,442 37 2,033 2,324 2,421 30 2,084 2,382 2,481 30 2,306 2,635 2,745 1,770 2,022 2,107 30 2,224 2,542 2,648 3,654 4,176 4,350 1,341 1,533 1,596 19 t 1,732 1,979 1 2,062 3,024 3.456 fl 3,601 1,982 2,265 2,360 19 2,242 2,563 2,670 4.309 4,925 5,130 10 1,951 2,229 2,322 7 2,490 2.846 2,965 c®us LISTED APPHDVEO FPAt 10 Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or CompressionlGrooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing ( ft.) According to HLF for the 2006 & 2009 IBC (ASCE7-05 ) & cp for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20ft. 25ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1114 1361 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 2 112 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 6481 531 1 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 12351 10121 867 726 40 40 40 40 40 37 34 32 30 1 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC ( ASCE ?OS ) & Q for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft. 25 ft, 30 ft, 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1 1.25 1 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 1 19 18 1 114 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 BULL MOOSE TUBE CCLVIPANV 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 3254467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED j /4ONA "PA ( For Additional Information Contact (800) 325.4467 www.bullrnoosetube.com Or From Canada Call (800) 882-4666 sales(bulIrnoosetube corn 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa GmndeAZ Dallas, TX masurA ON 63017 11 MechancaT0 STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic Mechanical-I'5 Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-I outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts, All sizes of Style 920 and 920N are rated at 500psi/345OkPa working pressure on Schedule 10 and 40 carbon steel pipe, They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface, Additionally, the Vic-Tap 11'5 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating; Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "r nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. "Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Approved Date www.victaulic.com vcTAuLIc IS A REGISTERED TRADEMARK OF vlclAuuc COMPANY. '5 2017 vlcrAuLic COMPANY. ALL RIGHTS RESERVED. REVJ j(ctauIicr DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi13450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T Bolted Branch Outlets STYLES 920 AND 920N Ma, W06 Appro'. rv~ :- - 920~ 500 1.50 2.00 2.53 1.61 5.35 2.75 3.1 50 s 3450 38.1 51 64 - 41 136 70 1.5 - N (a) * 500 - 1.50 1.97 -4-- 2.53 -.----- 1.61 -.-- 5.35 2,75 4- -.------.------ 3.1 20 3450 38.1 50 64 - 41 136 70 15 - 1 (a) 920~ 500 - 1.50 1.85 2.53 ' 1.61 5.35 2.75 3,0'"' 25 3450 38.1 47 64 - 41 36 70 1.4 - 1/4(à) tU 500 1.75 2.05 2.75 3.00 1,61 5.35 3.00 3.5 -- 3.2 32 3450 , 44.5 52 70 76 41 136 76 1.7 1.5 1112 (a) t' 92014 500 1.75 2.03 2.75 ' 3.12 1.61 5.35 3.25 - 3.6 3.2 40 3450 44.5 * -o 52 70 79 41 136 83 1.7 1.5 2½ . ½ (a) § '* - 92014 500 ISO -r- - 2.21 2.74 - 1.82 -.-- 5.64 2.75 ---- 3.0 - 65 '< 15 3450 33.1 56 70 46 143 70 14 - Y4 (a) §0 - , 500 ISO 2.18 2.74 1.82 5,64 2.75 3.0 20 A I 3450 38.1 55 70 - 46 143 70 1,4 - ((a) § 500 1.50 2.06 2.74 1.32 5.64 2.75 2.9 25 3450 38.) 52 70 - 46 143 70 1.4 - I 'is f (a) u 500 1.75 2.30 3.00 3.25 1.82 6.29 3,00 3.5 3.2 32 3450 44.5 58 76 83 46 160 76 1.7 1.5 116 f (a) a -014 500 2.00 2.28 3.00 3.25 1.82 6.26 3.25 3.6 3.3 40 3450 50.8 58 76 83 46 159 83 1.7 1.6 76.1 1/2 (a) y - A 300 1.50 2.22 2.75 2.25 6.46 3.18 3.9 15 2065 38.1 56 70 57 164 81 1.8 - (4 (a) 300 1.50 I 2,19 I N 2.75 2.25 6.46 3.18 3.9 20 2065 38.1 56 70 - 57 164 81 1.8 - 1 (a) -ON 300 1.50 2.07 2.75 2.25 6.46 3.18 3.8 25 2065 38.1 53 70 - 57 164 81 1.7 - I/o (a) 500 1.75 2.30 3.00 3.31 4 1.92 6.29 4 3.00 3.5 3.2 32 3450 44.5 58 76 84 49 160 76 1.6 1.5 1½ (a) 500 . 2.00 2.28 3.00 3,31 1.92 6.29 3.25 3.5 3.3 40 , 3450 50.8 58 76 84 49 160 , 83 1.6 1.5 3 ½ (a) 920N 500 1,50 2.52 3.05 2.28 6.15 2,75 3.4 30 X 15 3450 38.1 64 78 - 58 156 70 1.6 - 1/4 (a) 3 500 150 2.49 3.05 2.28 6.15 2.75 3.4 20 3450 38.1 63 78 - 58 156 70 1.6 - 1 (a) 500 4 1.50 - 2.33 3.06 2.28 6.15 2.75 3.3 25 3450 38.1 61 78 53 156 70 1.6 - I 'I. (a) tD 500 1.75 255 3.25 3.56 2.28 615 3.00 3.8 3.7 32(b) I 3450 44.5 65 83 90 58 156 76 1.8 1.8 1 1/2 (a) f 500 . 2.00 2.78 3.50 3.56 2.28 615 3.25 4.1 3.8 40(b) L 3450 50.8 71 ' 89 90 58 156 83 1.9 1.8 2(a) 920N 500 I 2.50 2.75 350 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 635 70 89 90 58 172 99 2.3 2.1 3½ 2 920N 500 2.50 3.00 3,75 2.44 6.72 3.88 3.8 90 50 3450 635 76 - 95 62 171 99 - 1.8 TABLE CONTINUED ON PG. 3 " Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. t Center of run 10 end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify"BSPT" clearly on order, (b)For 76.1 mm threaded outlet, specify 21W BSPT clearly on order. Vds approved for fire protection services ri LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. wwW.vlctaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF vICTAuuC COMPANY. 0 2017 V)CTAUUC COMPANY. ALL RIGHTS RESERVED. 11,022 JctauIic' CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 11 M7 Ell 77f mt;fi 11110111111111111 STYLES 920 AND 920N Si7e No lZe'~Ufe4i alrl3rp.I1[.nI . rir 'V I -- _____________ TABLE CONTINUED FROM PAGE 2 4 Vi (a) a 920N 500 1.50 3.03 3.56 2.69 7.01 2,75 3.7 100 15 -- 3450 38.1 77 90 - 68 178 70 1.8 - 34(3) a 92014 500 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 76 90 - 68 178 70 1.8 - I (a a - 500 1.50 2.88 3.56 2.69 7.01 -------4.. 2.75 3.6 25 3450 38.1 73 90 - 68 178 70 1.8 - 1 ¼ (a) la N 500 1.75 3.08 3,76 4.00 2.69 7.01 3.00 4.0 3.6 32(b) 3450 44.5 78 96 102 68 178 76 1.9 1.8 1 'Ii (a) ta N 500 2.00 3.28 4.00 -- 0 4.00 2.69 1- 7.01 - 3.25 - -- 4.2 - 3.9 40(b) 3450 50.8 83 102 102 68 178 83 ----4- 2.0 1.9 2(a) la 9201`1 500 230 3.25 4.00 4.00 2.69 7.01 3.88 5.0 4.6 50 -- 3450 633 83 102 102 68 178 99 2.3 2.1 2½(a) 8 920 500 2.75 2i8 4.00 4,00 2.69 7.34 4.63 5.8 5.0 65 3450 69.9 73 102 102 68 186 118 2.6 2.3 76.1 mm 920 500 2.75 2.88 4,00 2.69 7.34 4.63 6.4 , 3450 69.9 73 - - 102 68 186 118 2.9 920 500 3.50 3,31 4.50 4.12 - 2.69 7.73 S.12 8.4 6.4 - - 80 3450 88.9 84 114 105 68 , 196 130 3.8 2.9 108.0 < o - N 9z0 500 - 1.75 ' 3.08 3.78 2.63 7.64 3.05 5.0 32 3450 443 78 96 - 67 194 78 -.a-- 2.3 - ---a--- 11/2 (3)0 920N 500 2.00 3.28 4.00 2.63 7.64 3.25 5.0 - 40 3450 50.8 83 102 - 67 194 83 , 2.3 - 2 (a) 9201') 500 230 3.25 4.00 2.63 7.64 - 4.00 4.0 so 3450 63.5 83 02 - 67 194 102 1.9 - 76.1 mm 920 500 2.75 2.88 4.00 4.00 2.63 7.64 4.29 8.0 7.8 3450 69.9 - 73 102 102 67 , 194 109 3.6 3.5 3(a) 920 500 3.50 ' 3.31 4.50 450 2.63 ' 7.63 4.88 6.8 6.5 80 3450 88.9 , 84 , 114 114 67 194 124 - 3.1 5.0 5 , 1½ (a) 8 920 500 2.00 4.03 4.75 4.75 3.16 9.70 3.69 7.4 7.6 125 40 3450 50.8 102 121 121 80 246 94 I 3.4 3.4 2 90 500 2.50 4.00 4.75 V 4.75 3.16 9.70 V 4.38 8,2 0 8.0 50 3450 633 102 121 - 121 80 246 II) 3.7 , 3.6 2½ (a) t 90 500 2.75 4,75 4,75 3.16 9.70 4.63 8.3 ' 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 76.1 mm 920 500 2.75 ' 3.75 4.75 3.16 8.0 a 3450 69.9 95 - 21 80 246 118 - 3.6 3(a) t 920 500 p 350 3.81 5.00 4.63 3.16 9.70 V 5.31 8.4 8.8 80 3450 88.9 97 127 118 _80 246 135 32 4.0 a 1330 x 2 920N 500 2.50 3.75 4.50 3.17 8.00 - 3.88 8.0 50 3450 63.5 95 114 - 81 203 99 3.6 - 920 500 3.50 3.81 ' 5.00 3.00 9.46 5.31 8.0 80 3450 88.9 97 127 - 76 240 135 3.6 TABLE CONTINUED ON P6.4 DIMENSIONS ;1 1 1 X-1 W-0 A rr GROOVED OUTLET -1 7 1 S W.- IM, j# FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-I cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HOPE pipe Sizes from 2 x W/50 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 9201'1 housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another $ Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victauUc.com '(It1J(ctauliicr VICTAuLIC IS A REGISTERED TRADEMARK OF VICTAuLIC COMPANY. 0 2017 VCTAULIC COMPANY. ALL RIGHTS RESERVED. 1LO2 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 r1v MiJ. I I'MrAl 11 STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 1103 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HOPE pipe Sizes from 2 x W/50 x 15 Trim through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920Ni housings cannot be mated to one another to achieve cross connections. NO." IP'euW61 Diniemions Weight Each 7& TABLE CONTINUED FROM PAGE 3 1397 X 11/i t 920N 500 200 3.78 4.50 3.30 8.23 325 7.0 40 - 3450 50.8 96 114 84 209 83 3.2 2t 500 2.50 3.75 4.50 3.30 8.23 388 9.0 50 3450 500 63.5 1.75 95 4.43 114 5.13 - 5.13 84 3.79 209 9.15 99 3.25 4.1 5.1 - 4.8 6 • 1 1/4 (a) " 150 32(b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 1½ (a) I-a 500 I '- 2.00 4.40 5.13 5.13 3.79 -.----.4------'- 9.15 -. 3.25 5.4 5.1 40(b) 3450 50.2 112 130 130 96 232 83 2.4 2.3 ___ 2(a) ta - - 500 2.50 - -,- 4.38 5.13 ..- 5.13 3.79 -_-I- 9.15 --• 3.88 6.0 5.6 50 3450 63.5 Ill 130 130 96 232 99 2.7 2,5 2½ 920 500 2.75 4.01 5,13 a .- 5.12 3.69 10.51 - 4.63 - - 8.3 -. 7.6 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 76.1 0 920 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 - 132 94 267 118 - 3.8 3(a) I- 920 500 - 3.50 4,31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4(a) I-a 920 500 4.50 3.81 5.75 5.36 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 I 1/2 0) 920N 500 2.00 4,41 5.13 3.63 9.40 3.25 7.8 40 , 3450 50.8 112 130 - 92 239 83 3.5 - 2 920N 500 2,50 4,38 5.13 3.63 9.40 ' 3.88 8.0 50 , 3450 63.5 111 130 - 92 239 99 , 3.6 - 76.1 mm 9 20 500 2,75 4,38 5.50 5,13 3.63 9.40 ' 4.63 9.5 9.5 3450 69.9 Ill 140 130 92 239 118 4.3 4.3 3 - 940 500 3.50 - 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 1080mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 - 137 , 92 , 239 155 - 4.5 920 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 100 3450 114.3 96.80 146 - 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate), t Available with grooved or female threaded outlet. Specify choice on order. I- Center of run to end of fitting. 4 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. wwwvictauUc.com ictaullie 'JICTAuuC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 '/ICTAIJUC COMPANY. ALL RIGHTS RESERVED. Ar. ____________ 1iO2_4 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 4/200 x 100 mm Size Style IMaiilo,l, No Presure(dl Dimensions Im TABU CONTINUED FROM PAGE 4 1 165.1 r N 500 1,50 388 - 4.56 3.79 9.34 2.75 8.0 25 3450 38.1 99 16 - 96 237 70 3.6 - 114 500 1.75 4.43 -4- 5.13 . 3.79 9,34 ---------. 3,25 8.4 -4.--. 32 3450 44.5 . 113 130 - 96 237 83 3.8 - 1½ (a) to - 500 2.00 4.41 . 5.13 -.---e--- 5.13 3.79 -----4--------"- 9.34 3.25 8.4 5,4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2(a) t N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 Ill 130 130 96 237 99 3.9 2.7 76,1 mm 4. 500 - _._..____ 2,75 - 4.01 __._....._ 5.13 __•. 5.21 __,_ 3,63 10.51 4,63 .• - 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 3(a) to -.- 920 500 330 4.31 530 - - 5.13 3.63 a- -. 10.51 --•-• 5.31 - --------- 10.2 8.4 30 3450 88.9 110 -#--_ 140 130 92 267 135 4.6 3.8 4(a) t° 920 500 4.50 3.81 .-.+- 5.75 - 5.38 -- 3.63 -. -4. 10,51 6.25 . -.---- 10.5 - 8.4 100 920 3450 500 114.3 2.75 97 5.44 146 ---a.--- 6.19 137 - .... 6.25 92 4.81 267 12.42 159 4.50 4.8 11.6 3.8 11,6 8 x 2 (a)t 200 50 3450 69.9 138 157 159 122 316 114 5.3 - 5.3 2½ (a) 1' 920 500 2.75 5.07 6.19 - 6.19 4.81 12.42 - 4,50 11.6 11.6 65 -a 3450 69.9 129 157 157 122 316 114 5.3 5.3 761 mm, 920 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 3.450 69.9 133 - 159 122 316 116 - 5.3 3(a) to 920 500 330 5.31 6.50 630 4,81 12,42 5.31 12.6 11,6 80 3450 88.9 135 165 I a 165 122 316 135 5.7 5.3 4(a) to 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 125 tOO 3450 114.3 122 171 162 122 316 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. if Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings: (a) British Standard female pipe threaded outlet is available as listed. Specify"BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2/2" BSPT clearly on order, § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 9201\1 housings cannot be mated to each other to achieve cross connections. www.victaulic.com v1CTAuuc Is A REGISTERED TRADEMARK OF VICTAuLtC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. / ctauIic' 1102,..5 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cy and Ky Values I Values for flow of water at +60F/+16°C are shown in the table below. Formulas for Cy/K, Values: AP Q, C 2 Q = C x Where: = Q2 Where: Q = Flow (GPM) - K 2 0 = Flow (m3/hr) = Pressure Drop (psi) V P = Pressure Drop (Bar) C = Flow Coefficient Q = K x /6_P KV = Flow Coefficient Exaggerated for clarity Equivalent Outlet Size 40 Carbon Length of Schedule Steel Pipe OUTLET 1SIZE 1 ) I ½ 0.840 2 - 11 15 j 21.3 94 34 1.050 16 20 26.7 4 - 13.7 1.315 3 8 - 21 25 .33.7 18 1 '/4 1.660 5 ½ 6 50 48 32 42.7 429 411 1 ½ 1.900 11 11 53 53 4 0 98.3 . 45.4 2 2.375 9 10½ 112 104 50 603 96 891 2 ½ 2.875 20 12'/2 119 150 65 ! 730 102 _128.5 76.1 mm 3.000 16 151 76.1 138.1 _- 3.500 14 15 ½ 249 237 80 889 213.4 203.1 4 4,500 20 22 421 401 100 114.3 360.8 I 343.6 Hazen-Williams coefficient of friction is 120. 'Pipe with a wall thickness of O.165ini4.2mm. 1 FireLock Innovative Groove System (IGS) outlet www.victaulic.com Ac- IIA2_6 tauiicvICTAULIC IS A REGISTERED TRADEMARK OF VICTAUUC COMPANY. D 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Rijn Size Outlet Size Pipe App(oval Rated Wofling Preisures Agency - psi&Pa 21/2 -6 2.875 - 5,625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2.875 - 4.500 - ---- Al ----- OF 2755 300 2155 300 ----------------- 2755 300 1999 290 1599 - 232 2496 352 21/2 -4 65-100 73.0-114.3 2065 2065 2065 1999 1599 2496 21/2 -4 2.875 - 4,500 All SF 300 300 300 290 232 762 65-100 73.0-114.3 5.625 -.---- ------ o 2065 300 2065 300 2065 250 1---- 1999 290 1599 232 2496 362 ______ 6 ISO 68.3 6.625 -• ------.----- ' ------4. 30 40 2065 -----.- 300 2065 300 1724 300 p ------'4-----------•--.•-----',--------.. 1999 290 1599 232 2496 352 6 150 168.3 ' 2065 2065 2065 999 1599 2496 8 8.625 1 10,40 400 -- - - - 145 - 200 219.1 ' 2755 - - - 1000 8 ___--- 8.625 1 300 250 - 145 - 200 219.1 2065 - 1724 1000 8 8.625 34 30,40 300 - 300 - 145 - - 200 219.1 ' ' 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyne-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC.TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4 - 87100 - 200 MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-8a11 Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4/100mm, 57125mm, 6/150mm and 87200 mm diameter pipe. The Style 931 comes with a 2W/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. www.victaultc.com ,,j(ctaulIcr vlcTAuuc Is A REGISTERED TRADEMARK OF vIcTAuuc COMPANY. 02017 vICTAULIC COMPANY. ALL RIGHTS RESERVED. REU1 11027 STYLES 920 AND 920N INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com %,4'ctaulic 11.02 1480 REV N UPDATED 12/2017 '/ICTAULlC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 '/ICTAULIC COMPANY. ALL RIGHTS RESERVED. 1t492J. iml STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 4'4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1Y4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Date Approved Date___________________________________ www.victaulic.com - vlcrAuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vicrAulic COMPANY. ALL RIGHTS RESERVED. taukc W2J DIMENSIONS IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 STYLE 922 mches/mm Diameter 9D Dimensions a - - - inches/millimeters 1 1/4 ½ 32 15 1 3/16 30.2 1.30 33.0 1.83 46.5 1.10 27.9 3.87 98.3 2.56 65.0 1.0 0.45 20 Y4 l/6 30.2 1.28 32.5 1.83 46.5 1.10 27.9 3.87 98.3 2.56 65.0 1.1 0.50 1 25 1 /6 30.2 13,16 . 30.2 -I---- 1.52 38.6 1.42 36.1 2.18 55.4 1.95 49.5 1.10 27.9 1.22 31.0 - -------,--.---------,------ 3.87 98.3 4.08 103.6 2.56 65.0 2.56 650 ------.-.- 1.2 0.54 - ____ 1.2 0.54 1½ 16 40 15 ~ 20 11/16 . 30.2 1.40 35.6 1.95 49.5 1.22 31.0 4.08 103.6 2.56 - 65.0 1.2 0.54 1 25 13/16 30.2 1 3/, 30.2 1.64 41.7 1.66 42,2 2.30 58.4 - 2.19 55.6 1.22 31.0 1.46 37.1 4.08 103.6 4.60 116.8 2.56 65.0 2.56 65.0 1.3 0.59 1.3 0.59 2 16 50 15 'Y4 20 13A6 30.2 1.64 41.7 2.19 55.6 1.46 37.1 4.60 116.8 2.56 65.0 1.4 0.64 1 25 1 /,6 30.2 1.88 47.8 - ---- -- .- 2,54 64.5 - 1.46 37.1 - - -6--- 4.60 116.8 - 2.56 65.0 1,5 0.68 21/2 x ½ 65 15 1/6 - 30.2 1,91 48.5 2,44 62.0 - 1.71 43.4 5.40 137.2 2.56 - 65.0 1,6 0.73 3/4 20 13/16 30.2 1,89 48.0 2.44 62.0 1,71 43.4 5.40 137.2 2.56 65.0 1.6 0.73 13/16 30.2 2.13 54.1 2.79 , 70.9 1.71 43.4 5.40 137.2 2.56 65.0 1.6 0.73 - 1 25 ½ 76.1 mm X 15 13/16 30.2 1.91 48.5 2.44 - 62.0 1.71 43.4 5.50 139.7 2.56 65.0 1.6 0.73 V4 20 j3/3 30.2 1.89 48.0 2.44 62.0 1.71 43.4 5.50 139.7 2.56 , 65.0 1.6 0.73 1 25 1 /66 30.2 2.13 54.1 2,79 70.9 1.71 43.4 - 5.50 139.7 2.56 - 65.0 1.7 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com \41 tauIicP vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 viciuuc COMPANY. ALL RIGHTS RESERVED. 1042.2 RVG STYLE 922 JPS CARBON STEEL PIPE HOLE CUT PRODUCTS 10.52 PERFORMANCE Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL Run Size x Outlet Size 213, Section 16) (C=120). FT 76.1 mm x Jr Hazen-Williams coefficient of friction is 120 www.victaulic.com Zictaulfe VICTAULIC IS A REGISTERED TRADEMARK OF vlClAutJc COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 ictaulic viciuic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 viciuuc COMPANY. ALL RIGHTS RESERVED. _______________ 10,52 LZML3Mii x'iIU llui iJ SMITH ..., COOPE IW INTERNATIONAL Ductile Iron Threaded Fittings - - - Lisfii6ciflcafions - branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP Ductile iron castings conform to ASTM A536 c &us LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 - 650 300 c®uS <~> APPROM LISTED Fig. 35E 390° Elbow Size in Part a A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0,3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E3014 1.94 18 36 1.1 35E 3020 2,25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 - 3iJ Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x 3/4 35RE3012006 1.45 1.63 35 70 0,6 1-1/4x1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-1/4 35RE3014012 182 1.88 18 36 1.0 2x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35RE3020006 1.60 1.97 18 36 1.0 2x 1 35RE3020010 1.73 2.02 16 32 1.2 2x 1-1/4 35RE3020012 1.90 2.10 12 24 1,3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 1 35RE3024014 2.16 2.51 -6 -12 2.2 2-1/272 2 35RE3024020 2.39 1 2.60 6 12 2.5 Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 1 20 1 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 80 160 0.3 3/4 3513006 1.31 30 60 0.5 1 3513010 1.50 25 50 0.7 1-1/4 35T3012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 1 3513024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-7664)076 • FAX (323) 890-4456 • wwwsmirhcooper.com c@.LUS <~~ Fig. 35RT3 - Reducing Tee LISTED Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x 1/2 35R13006004 1.20 1,20 1.22 60 120 0.4 1 x 1/2 35R13010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x3/4 35R13010006 1.38 1.38 1.45 25 50 0.6 1 x3/4x3/4 35R13010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 35R13010006010 1.50 1.45 1.50 25 50 0.7 1-1/4x1/2 35RT3012004 1.34 1.34 153 20 40 0.8 1 1/4x1/2x1 1/4 35RT3012004012 175 153 1 25 50 09 1-1/4,x3/4 35R13012006 lAS 1.45 1.62 15 30 0.9 .1-1/4x3/4x1-1/4 35RT3012006012 115 - .62 115 20 40 1.0 1-1/4x1 - 35R13012010 1.58 1.58 1.67 15 30 1.0 1-1f4x1x1/2 35RT3012010004 1.34 1.26 153 25 50 0.7 1-1/4x1x3/4 35R13012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x1x1 35R13012010010 1.58 1.50 1.69 20 40 0.9 . 1-1/4x1x1-1/4 35R13012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35RT3014004 ir = .1 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35R13014004012 1.81 1.56 1.88 24 48 1.1 1-112x1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 35RT3014006012 1.94 1.66 188 20 40 1.1 1-1/2x3/4x1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2xlx1/2 35R13014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2xlx1 35R13014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-112x1-1/4 . 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35RT3Ô14012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4x3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35R13014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35R13014012012 1,82 115 . 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2x1/2 35R13020004 1.49 1.49 ir 10 20 1.5 2x3/4 35R13020006 1.60 1.60 1.97 10 20 1.6 2x1 35R13020010 1.73 1.73 202 8 16 1.7 2x1x2 35R13020010020 2.25 2.02 2.25 8 16 1.9 2x1-1/4 35R13020012 1.90 1.90 2.10 8 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35R13020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35R13020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x 1-1/4 35R13020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 1 35R13020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1x1-1/4 35813010012 1.67 1,67 1.58 20 40 0.9 lx1-1/2 35813010014 1.80 1.80 1.65 15 30 1.0 1-1/4xlxl-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35813012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 35813012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4x2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 358T3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-76640076 • FAX (323) 8904456 • wwwsmthcoper.com 112 A Fig. 3503 - Straight Coupling with Ribs Size in Pad Number A in - Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1,63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 1 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 3.00 9 2.2 C@US <e> APPROVED LISTED Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in PCklD Weight lb Inner Master 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 35R03010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 12 x 1 (not hex) I 35RC3020010 1 2.81 1 20 40 1 1.0 Fig. 35HB3 -Hex Bushing Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35HB3010004 1.06 180 360 0.2 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-112x1 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2 x 35HB3020010 1.38 40 80 0.6 2x1-1/4 35HB3020012 1.38 40 80 0.6 2x 1-1/2 35H83020014 1.38 40 80 0.6 Fig. 355P3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 1 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 mim .01fla Fig. 35U 3- Union with Brass Seat Size in Part Number _______________ A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 1 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-7664)076 • FAX (323) 8904456 0 wsmithooercom A. A. Size in Part Number ____ A in Packing Weight lb Inner Master 1 35X 3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 1 2.25 6 12 2.8 c®us Fig. 3313- Cross LISTED Fig. 35R13 - Reducing Cross Size in Part Number I A in B in Packing Weight lb Inner I Master 1-1/4 x1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2x1 35RX3014010 1.80 1.65 12 24 1.4 2x1 35RX3020010 1 2.02 1.73 8 16 2.0 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 1 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3 - Ream Clamp Size in Part Number A in Packing Weight I lb Inner I Master 3/8 35BC3003 0.75 100 200 0.3 1/2 35BC3004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL • TOLL FREE I-800-76640076 • FAX (323) 8904456 • www.smiihcooper.com 114 than ?rfnaf 10falb NtLeaa than rwrw SAMMYS® FOR WOOD No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured In the U.S.A. anvM a adeo dernonstitUan at wwwjtwbulldex.com 1(4' 8002957 GSTIOO 1/4x1' 210 (7/16'OSB) 25 125 670 (3/4' Ply) 1t4 8003957 GST200 1/4x2' 1760 (Fir) 25 125 3/8' 8007957 GST 10 114c1* 210 (7l16 OSB) 300 25 125 670 (3/4' Ply) 3/8 8008957 GST20 114x2 1760 (Fli) 850 1475 25 125 3/8' 8068925 GST2O-SS 1/4 x2' 1760 (Fir) 850 25 125 #14 Black (T 3/8' 8009925 GST2S-380 318x2-112' 2113 (Fir) 1500 25 'IT S -1 Nut Driver 318' 8010957 GST30 114x3 2060 (Fir) 1500 1475 25 125 Part#8113910 3/8' 8069925 GST3OSS 1/4*3' 2060 (Fir) 25 125 1/7 8013925 GST2 114x2" 1760 (Fir) 25 125 IT 8015925 GST3 1/4*3' 2275 (Fir) 25 125 f4i*r5yer fl49L0 a WA1*CWx'W7TA E~ v eaL SPKM 1dM ORWNWER The nut drivers were ned with a unique splrti-cff feature which provides fast and safe installation each time. When the face of the driver comes into corflicctwfth the material you are instating Irdo, continue drflhlng anti nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations, 00W Re Pac#8/l49L0 'Mayr rgqintmanufacturer. MR, ~ OTOM VS Not less than 7noa*mtWidth - (1-117pI7p not tessthan 21/7jrenaJwWth4'35'pipe 4 Mlfrrvn 2.11? from bottom for brariM eo.MThtoium3°fron bot- tom. toni for maIn fneo Eupfty TNo rmtmanIrieft not am to Tor Ndw POM mAV on /1 WA been ft I- lJ1t L. No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. ThlvP — .., leqmha video dmeosden\ w,wMwbuIIdex.comJ Eliminates distortion of threaded rod. Accommodates up to 3 '/° x 12 pitch roof. 'Mows 17° deflection from vertical. Saves time from traditional methods. Reduces installation costs. C. Manufactured in the U.S.A. 25 125 I 3110 t l-J/4 i'IUD fe wou veruca I L Dim. Lumber 903 Dim. Lumber 1/7 8303957 SH-GSTICST 2.0 51160-3/4' 1-3/4' 1406 @ 45'off vertical Dim. Lumber May require pre.dnlflng connuf I mist manufacturer. ø27 25 125 .1.'.:: - "u-- • I t #14 Black Nut Driver Part ft 8113910 Pre-drill a 5I8 hole with a regular drill or hole saw. Insert SST screw into #14 black nut driver. With wing nut and washer on bolt, insert wing nut through surface, and begin installation. I When bolt is secure and nut driver spins free, stop drill motor and remove. Pre-Cast Hollow Core SST screw is now ready to receive 1I4, 3/8, or Metric all Concrete thread rod or bolt stock. I . 3/8 8064925 SST 30 1/4 it 3 450 (Lath & Plaster) 25 125 404 (2 Layers 5/8 Rock) 3/16 eyelet to accommodate common wire size. [CC approvals can be found at v.ltwbuildex.com under Evaluation Report # ER-5367. I Approvals Substrate Part Number Model Point Description Overal Total Length Ultimate Pullout (Ibs) Max Gauge ICC Test Box Case Load (Ibs) Oty Oty - j__ICC STEEL 8107957 CWSD 1 Teks 1/4 x 1 2 472 (20g) 16 a. 170 (20ai)'25'ni'125 -[ICC STEEL 8190957 CWSD 15 Gimlet 1/4x 1-112 2.3/4 472 (20 g 20 ga. 170 (20 ga.) 25 125 WOOD Teks 1393 (Fir) [JcC STEEL 8108957 CWSDZ Teks 1/4x2 3-1/4 472 (20 ga) 16 ga. 170 (20 ga.) 25 121 CWIT ICC 8110910 COAT Installation Ted 1 Installation Toot Ones not comply will, ROHS requienents Part #8110910 -Adaptor Plug (a) The Pole Tool and Universal Socket Kit Socket Driver for SAMMYS (b) provide easy and safe installation for. Socket Driver for Ceiling Wire Screws (c) Socket Driver for 1(4" Standard Nut Drivers (d) - Sammys - Jack Chain Stud Plug for Viper or Ladd Powder Actuated Attachment (e) - Threaded Rod - Wire (Items not sold seperately) - Penal Rod - Screws - Ceiling Screws Wawa video d°) for retrofit and hard-to-reach projects in witwbufldeLcom wood and steel. S. MMYS *—DUTrTE STAY UP TO CODE! -, t.fta3*y.r ,ifts. 015 V4ATD Fit! Complies with NFPA 13 Code Changes. Flashing for dry pendant sprinklers subject to extreme temperature changes. One piece construction is easy to install, Pipe diameter markings ensure accurate fit. EPDM temperature range of -65°F to +250°F. 1/4"- 1-1/8" 1-3/4' 20 4003910 1 114". 2' 4-3/4" 3 10 1004910 2 1-3/4" - 3-1/4" 6-1(4" 4" ioJ L_ 8123910 Pole Tool 6 (3'- 6) 1 - 8124910 Pole Tod 12'(4'-12') 1 8125910 Pole Tool 18(6-18) 1 8126910 Pole Tool 24'(8'- 24') 1 8127910 Sammys Socket Driver 8128910 Ceding Wire Socket Driver for wire and chain 8129910 Universal Pole Tool Socket Kit 1/2°, 3/4', and 1" threading Magnetic strip for ease of use Pocket Sized Lightweight 3-vial design for measurement of 01, 45°, and 900 angles APPROVALS 8007957 GST 10 3/8 Vertical CPVC 11/2' 300 I.1/2' 8020957 SWG 10 3/8' Horizontal CPVC 1.1/2' 300 1-112' 8008957 GST2O 3/8' Vecal 21I2" __ 850 fl/2 4 75 i1/ZJ 8068925 GST2O-SS 3/8" Vertical 2-112' 850 1-112' - L.00957 GST3Q 318" Vertical 4" 1500 1-1/2" 4" 1475 1-1/2" j 8009925 GST25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25'380 3/8" Horizontal 8021957 SWG 20 3/8' Horizontal 2-1/2' - 3""" 1050 1-1/2' --j SWO 20-SS 3/8" Horizontal 2-1/2" 07R2i5 850 1.1/2' 8269957 SH-G$T/CST2O 3/8' 45' Angle off Vertical 2-112" 850 1-1/2' 269957 $H-G$T/CST 20 3/8" 45" Angle off Vertical 00 _J 8139957 SH-GSTZO 3/8" 17"AngteoffVertical 1050 1-1/2' 4 1475 1-1/2' 8038957 PSTR 1 3/8" Vertical 4". 1500 .035' 4" 1475 . .105' 8037957 DSTR 1-1/2 3/8" Vertical 1500 .035" 4" 1475 .105' 8039957 OSTR 516 3/8 Vertical 4 1500 037 4 1475 8045957 DST 516 3/8' Vertical 4 1500 .188' 4" 1475 .188" 8046957 TEK5O 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8' Horizontal 4" 1500 .037" 4" 1475 .060' 8056957 SWOR 516 3/8' Horizontal 1500 037 41475 060 8054957 SWOR1-1/2 3/8' Horizontal 4" 1500 .037" 4" 1475 .060" r8 957 STRI3/8" 17" Angle off Vertical 4' 1500 .035" 4" 1475 105'I 8268957 SHTEK 50 3/8" Vertical 70" Angle off Vertical 2-1/2" 4" 850 1500 8150922 XP20 3/8" Vertical 2-1/2" 850 .027" 8153922 XP 35 3/8" Vertical 4" 1500 .060" L 8294922 SW 20 3/8' Vertical or up to 45" 2" 750 027" 2" -635 .02T 8295922 SXP35 3/8" Vertical orupto89° 3-1/7 1250 .060" 2' 635 .029' 8293957 SWXP35 3/8" Horizontal 3-1/2" 1250 SAMMYS FOR CONCRETE -PIPE HANGER I 8059957 CST 20 3/8" Vertical 4" 1475 3000 j 8061957 SWC2O 3/8' Horizontal 4" 1475 3000 8150922 XP 20 3/8' Vertical 2-1/2" 850 Pre-Pour Structural @ 3000p5i 8150922 XP 20 3/8" Vertical 2-1/2' 850 Post-Pour Range llLWC!53SPCF(lbs/ft3) 8150922 XP 20 3/8" Vertical 250 .035' 8153922 XP 35 3/8' Vertical 250 185 o2r 8181922 XP 200 114" Vertical 185 .02r i 8294922 SW 20 3(8' Vertical 170 :c 45' 80 02 8295922 SXP35 3/8" Val 8293957 SWXP 35 3/8' Horizontal 80 .060" 8153922 XP 35 3/8' Vertical - 500 .060" Max 4 trade size EMT &6 trade sze RMC, IMC, and rigid PVC conduit 294922 SXP2O 3/8' Vertical 283 .027' Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SW 35 3/8" Vertical 500 .060' Max 4 trade size EMT& 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SW 35 3/8' Horizontal 500 .060' Max 4 trade size EMT & 6 trade sza RMC, IMC. and rfid PVC conduit 8149957 CZ2000 1/4' or 318" Onto Vertical Rod Gau9eNo. 229a. - 20 g Nominal Decimal Equivalent: .030' .036" 'SWG 25-340 Maximum pipe size in composite wood joist allowed by UL is 3-1)2" SWG 25-380 Masimum pipe size in wood timber or pilot allowed by UL is4" SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1)2' -SWG 20 Maximum sise size in wood timber or best allowed by UL is 2' Complies w/ NEC Standards a16 go, 14 12a.1!8' 3116" 1114" .048" .060" .075" .105" .125" .188" .250' UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: S times weight of water-tilted schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UI were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-puriin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Prese was completed using (.030') or 22 gauge steel metal deck. Sammye Nut Drivers Special nut drivers were designed lobe used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500.1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at w,itwbuildex.com Sammys for Seismic Please visit www.ltwbulldex.com for our current Seismic product offerring, Vibratory Environments For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported, Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model lIRoot Diameter GST 20 .182" 1/8" GST 25-380 280" 7/32" SWG 20 .187 1/8" SWG 25-380 280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling, NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com YL W ED £UOL5TCASUSIFUJUJ*fl -n Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Manufactured in the U.S.A. Products EM Contact information MUCfl DJSA Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 Fig. 25 - Surge Restrainer Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer Is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-UNE 1375 Sampson Ave • Corona, CA 92879 9 800.786.5266 • FAX: 951.737.0330 Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish — Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved C@03 U3TEO Seismic Restraints System Size Range - Secures 3/8" thru 7/8' hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD), For additional load; spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 D OFFICE/MANUFACTURING FACILITY . 1375 SAMPSON AVE. . CORONA, CA 92879. PH; 951731.5599. FAX; 951.737.0330 CUSTOMER SERVICE 800.786.5266 www.tolco.com H. 200-2/2 to 200-8 Fig. 200 Fig. 200$ Fin. 200 - "Trimline" Adjustable Band Hanaer (Cooper B-Line Flu. B3170NA ®TOIcO' Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper 6-Une Fig. B3170NFF Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Une Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes, Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design ' keeps adjusting nut from separating with hanger. Hanger is easily 44 installed around pipe, For hanger with non-captured nut order Fig. 200S, (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2° (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and H 200-1 200.2 Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). 9. Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FMDS2-0. Fig. 200C Fig. 200F 1 fltiu. 200-/2 Pipe 1/2" )IIb Size (15) Rod Size /8"-16 3/8" in.in. (79.4) 2I8" (MM) (66.7) Approx.: IW ii . 11 (5.0) 200-I4 3/4° (20) /8°-16 31/8" (79.4) 2I2" (63.5) 11 (5.0) 200-1 1" (25) I"-16 3I8" (85.7) 2I8" (66.7) 12 (5.5) 200-1I4 1/4" (32) /8"-16 33/4" (94.0) 2f8" (73.0) 13 (5.9) 200_1112 1/2" (40) /8"-16 3/8" (98.4) 2/8" (73.0) 14 (6,4) 200-2 (50) I8"-16 41/2" (114.3) (76.3) 15 (6.9) 200_21/2 21/2 ' (65) /8"-16 5/8' (142.9) 41/8" (104.7) 27 (12.3) 200-3 - 3° (75) /8"-16 57/' (149.1) 4" (101.6) 29 (13,3) 200-3/2 31/2" (90) /8"-16 7/8' (187.3) 51/4" (133.3) 34 (15,6) 200-4 4" (100) I8°-16 7/8" (187.3) 5" (127.0) 35 (16,0) 200-5 (125) 1/2"_13 9/8" (231.8) 6I4" (158.7) 66 (30.2) 200-6 (150) 1/"3 101/8" (257,2) 53/4" (171.4) 73 (33.4) 200-8 8" (200) 1/"_13 131/8" 1 (333.4) 8f4" 1 (222.2) 136 (62.3) All dimensions in charts and on drawings are In Inches. Dimensions shown in parentheses are In millimeters unless otherwise specified. Pill- go COOP B-Line Fig. 200-21Iz to 2004 ®YOLW c®Us LISTED Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: . (1/2" (15mm) thru 2" (50mm)) Flared edges ease Installation for all pipe €1, types and protect CPVC plastic pipe from abrasion. Captured design ' keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. '••., ....]- (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. . Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) . in the USA (UL) and Canada (cUL.) for steel and CPVC plastic pipe and 206-1 to 200-2 Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10, Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Part No. 200M8-1/2 Pipe 1/2 Size (15) RodlTI1w MB A I 31/8° (79.4) I 2I8 B (66.7) Approx.W I 11 (5.0) 200M10-1/2 1/2' (15) M10 31/8" (19.4) 2I8" (66.7) 11 (5.0) 200M8-3/4 3/4" (20) M8 31/8" (79.4) 21 /2" (63.5) 11 (5.0) 200M10-3/4 3/4' (20) MIO 31/8" (194) 2112' (63.5) 11 (5.0) 2001V18-1 1° (25) MB 3%" (85.7) 2I8° (66.7) 12 (5.5) 200M1-1 1" (25) M10 318" (85.7) 218" (66.7) 12 (5.5) 200M8-11/4 11/4' (32) MB 33/4" (94.0) 2I8' (73.0) 13 (5.9) 200M10-11/4 11/4° (32) M10 33/4" (94.0) 2I8" (73.0) 13 (5.9) 200M8-1 '/2 11/2" (40) MB 3/8° (98.4) 2/8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) M10 3718" (98.4) 218" (73.0) 14 (6.4) 200M8-2 (50) MB 41/2" (114.3) (76.3) 15 (6.9) 200M10-2 2° (50) M10 41/2" (114.3) 3" (76.3) 15 (6.9) 200M-21/2 21/2" (65) M10 5I" (142.9) 41/8' (104.7) 27 (12.3) 200M-3 3" (75) M10 5I8' (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) M10 7 /8" (187.3) 51/4" (1333) 34 (15.6) 200M-4 4° (100) M10 7/8" (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4° (158.7) 66 (30.2) 200M-6 (150) M12 101/8 (257.2) 6/4" (171.4) 73 (33.4) 200M-8 8' (200) M12 131/8" (3334) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. pp- 00 COOP B-Line Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Th '1 !'.i Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Fumished with /8°-16 or 1/2°13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada"" (cUL). Conforms to Federal Specification WW-H-171 E & A-A-11 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. Part f~o. • 200H-2-3/8 Pipe 2" in.in. Size RodTIh: (50) I8°-16 4/16' A (115.9) "-r- 3/32" B L1!J,J1.FYlwãI. i.r. (81,7) 48 (21.8) 200H-2-1/2 (50) 1/2"..13 4I32" (119.8) 3I8" (85.7) 45 (20.4) 200H-2112-318 21/2" (65) /8'-16 5/16" (134.9) 323/32' (94.4) 59 (26.7) 200H-21/2-112 21/2' (65) 1/2 -13 515/32' (138.9) 3/8" (98.3) 56 (25.4) 200H-3-3/8 (75) /8'-16 53/4" (146.0) 327/32' 1 (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"..1357/8" (148.1) 331/32' (100.8) 60 (27.2) 200Il-4-I8 4" (100) /8'-16 6I8" (174.6) 4/16° (112.7) 76 (34.5) 200H-4-1/2 4" (100) 1/20.13 71/32" (178.6) 419/32' (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PP_ 00 COOPER B-Line Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZT System Compatible Program* Certified to NSF/ANS/Std 61 -G *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. -u © 2012 Fire Protection Products, Inc. FPPt, LubeRtO are registered trademarks of Fire Protection Products, Inc. FGGIBM/CZ", Blaze-Master®, RowGuard Gold® and Corzan® are registered trademarks of Noveon IP Holdings Corp. IN is U.S.A. Description Pipef it® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FBC,y`." *FBCV System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipef it® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com WW © 2012 Fire Protection Products, Inc. FPPFi, LubeFit5 are registered trademarks of Fire Protection Products, Inc.bA FBC', BlazeMaster®, RowGuard Gold® and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FBC44/WA SYSTEM COMPATI&E *FBCTI System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance; Clear amber liquid. Packaging; 1 gl. (6/case) 5g1.Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product Is registered with CI-IEMTREC, a 24-hour emergency hot//ne. They may be reached at 1 800 424-9300. © 2013 Fire Protection Products, Inc. FPPF, ThreadR& are registered trademarks of Fire Protection Products, Inc. MADE W u,&A.