Loading...
HomeMy WebLinkAbout1770 FAIRLEAD AV; ; FA120033; PermitCity of Carlsbad Fire. Alarm Permit Permit No: FA120033 Job Address: 1770 FAIRLEAD AV Permit Type: FALARM Parcel No: 2150203301 Lot #: 0 Reference No.: Status: FINAL Applied 8/21/2012 Approved: 8/21/2012 Issued: 8/21/2012 PC #: Inspector: Project Title: VOSCANA BLDG 9 NEW/RESIDENTIAL Applicant: . . Owner: HCI SYSTEMS, INC 1354S. PARKSIDE PL ONTARIO, CA 858-560-7000 Fees ($) Add'l Fees ($) Total ($) Balance ($) 322 0 322 . 0 I CASSIA ROAD (EXISTING) all.UfE~Wd7l m.. 171r.17 Im VICINITY MAP CITY Of OCEANSIDE K04 WAY ye NOT TO SCALE \..... \ CITY OF VISTA MOAB SITE CITY OF \ ;(#• - OD SANMARcOS GA PACIFIC \ if OCEAN / CITY OF ENCINITAS HCI Systems Inc. FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Fire Alarm System Complete Material Submittal Prepared for: Voscana Flats - Condominiums Building #9 ,LJ Cassir5adat Poinsettia Ldne;. Cars 1 ad, California FIRE iT APF H) Subject to field in--, .,:1uired tests, notations h@feon. in Correspondence Mth apWficablereons. Tie L of l not be hek or any B Ontario • San Diego • Irvine • Northern California Corporate Office: 1354 South Parkside Place, Ontario, CA 91761 Phone: (877) 331-2084 FAX: (909) 628-7774 24-Hour Service: (909) 628-8886 Website:www.hcisystems.net Voscana Flats - Condominiums Building #9 Cassia Road at Poinsettia Lane, Carlsbad, California Manufacturer Device Model # Description C.S.F.M. # BOSCH FPD-7024 Fire Alarm Control Panel 7165-1615:0147 Include With: D7039 Multiplex Expansion Module BATB.40 Battery Box 7300-1615:0188 INTERSTATE SLA1146 26 Amp Hour Sealed Lead Acid Battery BOSCH D7050 Addressable Photoelectric Smoke Detector 7272-1615:175 Include With: D7050-116 Standard Detector Base 7300-1615:176 BOSCH D255 Conventional Heat Detector 7270-1615:0116 Include With: D253 Standard Detector Base 7300-1615:0115 BOSCH D7052 Multiplex Dual Input Module 7165-1615:0147 BOSCH D7044M Multiplex Mini Single-Input Module 7165-1615:0147 BOSCH D7053 Multiplex Input-Output Module 7165-1615:0147 BOSCH FMM-07045 Addressable Manual Pull Station 7150-1615:0122 BOSCH W.HSW 15CD Wall-Mounted Horn Strobe, White 7125-1615:0168 BOSCH W-STW 15CD Wall-Mounted Strobe, White 7125-1615:0168 BOSCH MIZ-24S-W Piezoelectric Mini-Horn, White 7135-1615:0150 BOSCH D370C Electromagnetic Door Holder 3550-1615:0164 O BOSCH Invented for life LFPD-.7-,O24)Fire Alarm Control Panels The(ffD-7O24JFire Alarm Control Panels (FACPs) can be used in commercial and public building applications such as schools, universities, manufacturing plants, and health care facilities. They are listed by UL for central station, local, auxiliary, and remote station systems. The FPD-7024 FACPs support four on-board initiating zones that can be expanded to eight using the FPC-7034. Each initiating zone supports two-wire and four-wire detectors configurable as Class A, Style D or Class B, Style B loops. Each zone can support up to 20 two-wire detectors, or any number of four-wire detectors depending on available power. Each FACP has a built-in digital fire alarm communicator transmitter (DACT). Enhance the FPD-7024 conventional system features by adding a D7039 Multiplex Expansion Module. Adding a D7039 Multiplex Expansion Module to the FPD-7024 turns the conventional FACP into an addressable FACP. The D7039 adds up to 247 addressable points to the base system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases the number of programmable relay outputs from 19 to 59 and expands system users to 100. Four initiating zones (expandable to eight); up to 20 two-wire smoke detectors per zone Built-in DACT Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A NAC power supply Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module Programmable through front panel interface, remote FMR-7033 Liquid-crystal Display (LCD) Keypads, remote programming software (RPS), or DX401OV2 or DX4020 [Functions Notification Appliance Circuits (NACs) Two Class A, Style Z or Class B, Style Y NACs provide up to 4 A of regulated 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be programmed to provide Temporal Code 3, California March, steady, pulsed, and synchronized output for either Wheelock or System Sensor notification appliances. User Interface A viewing port in the locked control panel enclosure door shows the system status light-emitting diodes (LEDs) and liquid-crystal display (LCD) while maintaining system keypad security. Unlocking the enclosure door provides access to the system controls for silencing off-normal conditions, zone bypassing, detector resetting, testing, other fire functions, and programming. These functions are also available on all FMR-7033 LCD Keypads connected to the system. Organized Event Display Sorts alarm, trouble, and supervisory events into categories and allows scrolling through specific events. History Buffer The system stores events in a 99-event history buffer. Note The number of events that can be stored in the history buffer increases to 499 with the www.boschsecurity.com addition of a D7039 Multiplex Expansion Category Product ID Product Description Module. Keypads and D7030X Eight-point LED annunciator Central Station Reporting Annunciators (eight red) The FPD-7024 FACPs send reports to two telephone D7030X-S2 Eight-point LED annunciator numbers (or IP addresses with a DX4020 Network (two yellow, six red) Interface Module installed) with full single, double, and D7030X-S8 Eight-point LED annunciator backup reporting. They communicate in BFSK, SIA, (eight yellow) Contact ID, Modem lila2, and 4/2 and 3/1 Tone Bursts. D7032 Eight-point LED annunciator expander Dirty Smoke Detector Monitoring (eight red) All on-board zones and FPC-7034 zones are continuously FMR-7033 LCD fire system keypad monitored for smoke detectors signaling a dirty condition FMR-7036 LCD annunciator using the Bosch Chamber Check feature and CleanMe Modules D132B Smoke detector reversing relay protocol. If a detector's smoke chamber is dirty, the module detector sends a CleanMe signal on the two-wire loop or a D184A Local energy kit dirty detector signal on the addressable loop. The control D185 Reversing polarity module panel annunciates that there is a dirty detector on the D275 EOL power supervision module loop or the address. The Chamber Check feature signals a dirty smoke chamber using the LED on the detector head. FPC-7034 _____ Four-point expander (Dr0.9 Multiplex expansion module Accessories The FPD-7024 enclosure has space for additional Option Bus D7035 Octal relay module Devices accessory modules and two D1218 (18 Ah) batteries or D7035B Octal relay module in box two D126 (7 Ah) batteries. DX401OV2 USB/serial interface module DX4020 Network interface module [certifications and Approvals NAC Devices Refer to FPD-7024 Device Compatibility List Technogram (P/N: F01U010791) Region Certification The following additional products are compatible with the FPD-7024 Addressable FACPs: USA UL UOXX: Control Unit Accessories, System (ANSI/UL 864) Category Product ID Product Description FM Detector Heads D7050 Addressable Photoelectric Smoke CSFM 7165-1615:0227 FIRE ALARM and Bases Detector Head CONTROL UNIT (COMMERCIAL) D7050TH Addressable Photoelectric Smoke FCC ESVAL04B7024 and Heat Detector Head FDNY- #6024 D7050-86 Detector Base CoA Modules D7042 Multiplex eight-input remote Brazil ANATEL 0383-11-1855 module D7042B Multiplex eight-input remote module in box [Installation/configuration Notes I D7044 Multiplex single-input module D7044M Mini multiplex single-input module Compatible Products D7048 Multiplex octal driver The following products are compatible with the FPD-7024 D7048B Multiplex octal driver in box FACP: D7052 Multiplex dual-input module Category Product ID Product Description D7053 Multiplex input-output module Batteries and D126 12 V, 7 Ah battery Pull Stations FMM-7045 Single-action manual station Power Supplies D1218 12 V, 18 Ah battery FMM-7045-D Double-action manual station D7038 Remote NAC power supply Detectors For two-wire detector compatibility, refer to FPD-7024 Smoke Detector Compatibility List Technogram (P/N: F01U010790) [Parts Included Quant. Component 1 FPD-7024 board in a static-resistant bag 1 Enclosure (P/N: 30897) 1 Lock set with two #1358 (D102) keys (P/N: F01U009775) 1 Transformer (P/N: F01U008702) 6 2.21 kUend-of-line(EOL) resistors (P/N: 25899 or 4998113202) 1 Hardware pack 1 Literature pack Note For the FPD-7024 to be addressable, a D7039 Multiplex Expansion Module must be installed. The D7039 is purchased separately. Technical Specifications Electrical Current (alarm): 8O) Current (standby): (OOm) Power (primary): 120 VAC, 1.2 A maximum, 60 Hz or 240 VAC, 0.75 A maximum, 50 Hz Environmental Environment: Indoor, Relative Humidity: Up to 95%, non-condensing Temperature (operating): +32°F to +120°F (0°C to +49°C) Mechanical Properties Color: Red Dimensions (HxWxD): 20.8 in. x 15 in. x 4.3 in. (52.8 cm 38.1 cm 10.9 cm) Material: Cold-rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) Indicating Device Circuits (IDC) Current: 44 mA maximum per loop Line resistance: 1500 Voltage: 24 VDC nominal Outputs NAC: 24 VDC nominal, 4 A maximum On-board Relays: Three Form C contacts rated at 5 A, 28 VDC Off-board Relays: Up to two D7035 Octal Relay Modules with each providing eight Form C relay outputs; contacts rated at5A,28VDC In an addressable system, up to 20 D7053 Multiplex Input-Output Modules are allowed per bus for a total of 40 Trademarks Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. uses the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringing the trademark. Chamber Check is a registered trademark of Bosch Security Systems, Inc. in the United States. CleanMe is registered trademark of GE InterIogix in the United States and/or other countries. Wheelock is a trademark of Cooper Wheelock, Inc. System Sensor is a registered trademark of System Sensor, a brand of Honeywell International, Inc. in the United States and/or other countries. I Ordering Information FPD-7024 FACP FD7O24) Four detector zones (expandable to eight); up to 20 two we S moke detectors per zone FPD-7024•LC FACP without Enclosure and FPD-7024•LC Transformer Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone FPD•7024-LT FACP without Transformer FPD7024•LT Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone. Available only in Latin America. www.boschsecurity.com An,orluem Europe, Middle East, Africa: Aeie.Poeific. Represented by Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Systems 130 Porinton Parkway P.O. Box 80002 11 Bishan Street 21 Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943 Phone: *18002890096 Phone:, 31402577 284 Phone: *66 6258 5511 Fox: *1 585 223 9180 Fox: +3140 2577 330 Fax: +65 6571 2698 secority.sales@us.bosch.com emea.socoritysystems@bnsch.com apr.securitysystems@bosch.com www.boschsecority.os www.boschsecurity.com www.boschsecurity.usia © Bosch Security Systems Inc. 20111 Data subject to change without notice 137612828271 Cur: en-US, V12. 22 Mar 2011 o BOS'CH Invented for life (D7039)Multiplex Expansion Module El The (703Multiplex Expansion Module is designed to enhance the conventional features of the D7024 or FPD-7024 Fire Alarm Control Panel (FACP). The D7039 connects directly to the FACP and results in a total of up to 255 addressable points. The D7039 also increases the number of relay outputs (to 58 on the D7042 control panels and 59 on FPD-7024 control panels), adds an additional 400 events to the history buffer for a total of 499 non-volatile events and also allows for up to 100 system users (an addition of 84 PINs from the base system). The D7039 can be programmed remotely from a PC using the RPS Remote Programming Software. Note The D7024 is not listed under UL864, 9th edition. [ertifications and Approvals Region Certification USA UL UL864, 9th edition FM CSFM 7165-1615:147 7165-1615:227 NYC-MEA 12-92-E, Vol. 14 Has two Class B (Style 4) multiplex buses (supports addresses 9 to 255) Provides one Class A (Style 6) multiplex bus (supports addresses 9 to 128) Expands number of user codes to 100 PINs Increases event history buffer to 499 events Compatible with RPS Easy to install I Installation/Configuration Notes Compatible Products The following products are compatible with the D7039 Multiplex Expansion Module: Category Product ID Product Description Control D7024 Addressable and conventional FACP Panels D7024-EXP Addressable and conventional FACP for ex- port FPD-7024 Addressable and Conventional FACP Mounting Considerations The D7039 mounts onto the control panel board inside of the control panel's enclosure using connector pins. The D7039 Input-Output board mounts to the inside wall of the enclosure for field wiring. Wiring Considerations Refer to control panel's installation guide for additional wiring requirements. www.boschsecurity.com 2 1 P7039 Multiplex Expansion Module Maximum Impedance: 50 Oat +20°C (+68°F) nominal Distance (approximate) Size 1170m 1.0mm2 1810 rn 1.5 mm2 3800 ft 18AWG 5950ft 16AWG Note Do not use shielded cable. Twisted pair is acceptable but not recommended. Note If used in fire applications, a minimum of 18 AWG wire is required. Parts Included Quant. Component 1 D7039 board 1 D7039 Input-Output board 3 Standoffs for input-output board 4 Standoffs for D7039 board 1 Literature pack [Technical Specifications Environmental Considerations Environment: Indoor, dry Power Requirements Current (load): 100 mA maximum each bus Current (alarm and standby): 15/ _max ii Resistance (bus wiring): 500 maximum Voltage (bus): 12 VDC nominal Voltage (input) 24 VDC nominal [Ordering Information (b7039 Multiplex Eipánsi Module (D7O (Enhancse the cnvntional features of thi D7024orFPY7024 0Fie Alarm Control Panel) ((FACP) providihg tótal of up to 255 address-) Americuor Pooch Security Systems. Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: *1 585 223 9180 securlty.sules@as.boschcom www.boschsecurlty.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Boo 80002 5600 JB Eindhoxen, The Netherlands Phone: 3140 2577 284 Fax: *31 40 2577 330 emeu.securisysystems@bosch.com www.boschsecurity.com Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Blshan Street 21 Singapore 573943 Phone: *65 6258 5511 Fax: *65 6571 2698 apr.socaritysystems@busch.com www.boschsecurlty.com © Bosch Security Systems Inc. 2010 I Data subject to change without notice T2593898763 I Cur: en-US, V6. 4 Jul 2010 Fire Alarm Systems I BATB Series Battery Boxes BOSCH Invented for. if i (BATB)Series Battery Boxes UL Approved Holds up to four auxiliary batteries The BATB Series Battery Boxes are a distinctive red for use in fire alarm systems. The(BATB-40)provides a single level (two battery capacity) of battery storage with an optional shelf that increases the battery capacity to four batteries. The BATB-80 has a mounted shelf and holds up to four batteries. Note The actual number of batteries the battery box can support depends on the size and weight of the batteries. Refer to Technical Specifications for specific information. These battery boxes are used with the following battery types: Gel-cell Nicad Sealed Lead-acid Wet-cell [Certifications and Approvals Region Certification USA UL NBSX: Household Burglar Alarm System Units (UL1023), UTOU: Control Units and Accessories - Household System Type (UL985), UOXX: Control Unit Accessories, System (UL864) CSFM 7300-1615: 188 I Installation/Configuration Notes I Compatibility Information The following products are compatible with the BATB Series Battery Boxes: Category Product ID Product Description Batteries: D126 12 V, 7 Ah Battery D1218 12V, 18 A Battery D1224 12 V, 24 Ah Battery D1238 12 V, 38 Ah Battery D1240 12 V, 4 Ah Battery Mounting Considerations The battery box with its batteries is heavy. Select a mounting location and method that can support the total weight of the battery box and up to four batteries. www.boschsecurity.com 2 IBATB Series Battery Boxes When mounting the battery box on wooden studs, use lag bolts. When mounting on cement walls, concrete anchors (not supplied) are required. Warning Do not mount on metal studs. Refer to the control panel's installation guide for information on calculating the number and type of auxiliary batteries needed for your application and for specific mounting location requirements for the auxiliary batteries. Wiring Considerations Refer to the control panel's installation guide for information on calculating the number and type of auxiliary batteries needed for your application and for specific requirements for wiring the auxiliary batteries. [Parts Included BATB-40 Quant. Component 1 Battery box (no shelf) with D101 (#1358) lockset 1 Literature pack BATB-80 Quant. Component 1 Battery box with shelf and D101 (#1358) lockset 1 Literature pack BATB-SHELF Quant. Component 1 Optional shelf 1 Hardware pack 1 Literature pack Batteries Total Dimensions (H x W x D) BATB-80: Four Weight Combined Total: 200 lb (90.7 kg) On Shelf (maximum): 100 lb (45.4 kg) Mechanical Properties Color: Red Dimensions (H x W x D): 22 in. x 21 in. x 7.5 in. (55.9 cm 53.3 cm 19 cm) Material 18 gauge (1.2 mm) cold-rolled steel Weight (without shelf): 27.5 lb (12.5 kg) [OrderingInformation BATB-40 Battery Box (BATB-40) The BATB-40 Battery Box holds two dry or wet cell batteries. The box can be used with fire alarm systems or intrusion systems. BATB-80 Battery Box with Shelf BATB-80 The BATB-80 Battery Box holds up to four dry or wet cell batteries. The box can be used with fire alarm systems or with intrusion systems. BATB-SHELF Optional Battery Shelf BATB-SHELF An optional battery shelf for the BATB-40. It allows two additional batteries to be placed in the battery box. Accessories D102 Replacement Key D102 Replacement key (#1358) for the D101 lock. Technical Specifications 1 Battery Box Capacities Batteries Total Dimensions (H x W x D) BATB-40 without shelf: 21 in. x 20.75 in. x 7.25 in. (53.3cmx52.7cmx 18.4 cm) BATB-80 bottom: 12.25 in. x 20.75 in. x 7.25 in. (31.1 cm 52.7 cm 18.4 cm) On shelf: 9.2 in. x 20.75 in. x 7.25 in. (23.2 cm 52.7 cm 7.25 cm) Number of Batteries BATB-40: Two BATB-40 with shelf: Four Ameflsoo, Europe, Middle East, Africa: Aoia.Paelflo: Represented by Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd. Security Systems 130 Perinton Parkway P.O. Boo 80002 11 Blshan Street 21 Fairport, New York, 14450, USA 5800 JO Eindhooen, The Netherlands Singapore 573943 Phone: +1800 289 0096 Phone: * 31402677 284 Phone: *65 6258 5511 F-*1 585 223 9180 Fax: +3140 2077 330 'ax: +65 6571 2898 security.salos@us.bosch.com emea.securItysystems@bosch.com apr.securitysystems@bosch.com www.boschsecurity.us www.boschsecurity.com www.boschsecurity.com C Bosch Security Systems Inc. 2010 I Data subject to change without notice T19B6540683 I Cur: en-US, V7, 4 Jul 2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7165-1615014 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model 07024 fire alarm control unit. Power limited, local, automatic, manual, noncoded, remote station, central station, waterflow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: (bMN; Control Uni~ D7034; 4-Zone Expander D7033; Keypad 07035, D703513; Expanded Relay Module 25899; End-of-line Resistor D184A; City Tie Kit 0185; Reverse Polarity Module D7014; Class A Adapter D7039; MUX Expander D7038; Remote NAC Expander D7015; Class ANAC Module D7042; Eight Zone Expander D704213, 07044, 07044M, 07052; Multiplex Expander Module D7048, 0704813; Octal Driver Module 07053; Multiplex Input/Output Module RATING: 120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 8th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum 07-05-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Listing No. 7165-1615:0147 Page 2 of 2 Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly 7165-0801:177 07-05-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWIIT, Deputy State Fire Marshal Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE CAL F1 E LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: APPROVAL: (7300-1615:018 Page 1 of 1 7300-- FIRE ALARM CONTROL UNITACCESSORIESIMISC. DEVICES BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com Models and BATB-80 control unit enclosures. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listees name, model number, and UL label. Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 01-06-2005KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division o BOSCH Invented for life D7050 Series Addressable Photoelectric Smoke and Smoke Heat Detector Heads Connects to the multiplex bus of the D7024 Addressable FACP Superior dust immunity Exclusive Chamber Check self-diagnostics Automatic sensitivity test features Easy disassembly for cleaning The Photoelectric Smoke and Smoke Heat Detector Heads are UL Listed, open-area photoelectric smoke detectors designed for use with commercial fire protective signaling systems and household fire warning systems (see NFPA 72, the National Fire Alarm Code). They are compatible with the D7024 Addressable Fire Alarm Control Panels (FACPs). They detect large smoke particles by scattering light from a pulsed infrared source operating with a gated, high-speed, photodiode infrared sensor. The symmetry of the optical chamber allows 3600 uniform smoke entry, but minimizes external light entry. Use both of these smoke detectors for detection circuits installed in areas where personnel are present. The D7050TH has an added fixed-temperature sensor. This expands the detector application to confined areas where a fire increases air temperature slowly and where there is a substantial increase in air temperature before the fire breaks confinement, such as furnace rooms, closets, and other confined areas. [Functions Detector Head and Base System The D7050 Photoelectric Smoke and Smoke Heat Detector Heads are part of a compound system of detector head and base. The detector base installs over a back box and contains all the wiring. The detector head attaches to the base by aligning the head with the base and turning it clockwise. No tools are required for installation other than the hex key used to tighten the tamper screw. Each detector head requires a D7050-B6 detector base. Chamber Check Self-diagnostics The detector meets NFPA guidelines for sensitivity testing, because you can visually inspect the detector and check the flash rate of the LED. If the calibration is out of factory-listed range, the LED on the detector double flashes once every 3 sec to 8 sec. Follow the instructions provided with the detector to clean it. The detector also sends a dirty chamber report to the control panel. LED Operation When the detector is operating normally, the LED flashes once every 3 sec to 8 sec. In alarm, the detector flashes at least once per second. Magnetic Test Feature Test the detector's operation by placing the SM K-TM Test Magnet next to the detector's LED for three www.boschsecurity.com consecutive flashes. This causes the detector to send an alarm. [çtifications and Approvals Listings and UL UROX: Smoke - Automatic Fire Detectors (UL268) Approvals: UL UROX7: Smoke - Automatic Fire Detectors certified for Canada (ULC529) cULus CSFM 7272-1615: 175 Factory Mutual Research NYC/MEA(12-92-E, Vol. 14) Complies with: Hong Kong Fire Services Department (HKFSD) Installation/Configuration Notes I LIhnical Specifications 1 Environmental Considerations Radio Frequency Interfer- No alarm or setup on critical frequencies in the ence (RFI) Immunity: range of 26 MHzto950 MHz forfield strengths less than 50 V/rn Temperature +32°F to + 100°F (0°C to +38°C) (normal operating): Note: The environment where these detectors are installed must be within the specified normal operating temperature limits. Mechanical Properties Color: Off-white Dimensions 4 in. x 1.3 in. (10.2 cm x 3.3 cm) (diameter x D): Material: High-impact, fire-retardant ABS plastic Power Requirements Compatible Products The following products are compatible with the D7050 Smoke Detector and the D7050TH Smoke Heat Detector: Category Product ID Product Description Control Panels D7024 FACP D7024-EXP FACP for export Detector Bases D7050-136 Two-wire base Remote DRA-12/24 12/24 VDC remote annunciator Annunciators TParts Included Quant. Component 1 Detector head 1 Literature pack Current (alarm): Current (standby): Power-up Time: 22 sec maximum Voltage (minimum): 8 VDC peak from the multiplex bus I Ordering Information LHead D7050TH Addressable Photoelectric Smoke and Heat D7050TH Detector Head Hardware Accessories DRA-12/24 Remote Annunciator (12/24 VDC) DRA-12/24 DT-2 Detector Removal Tool DT-2 SMK-TM Test Magnet SM K-TM Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: +31 40 27 83955 Fax: +31 40 27 86668 emea.securitysystoms@hosch.com www.boschsecurity.com Americas: Bosch Security Systems 130 Perioton Parkway Fairport, New York. 14450. USA Phone: +1800 289 0096 Fax: *15852239180 security.saies@us.bosch.com www.boschsecurity.us Asia-Pacific.- Bosch Security Systems Pre Ltd 38c Jalan Pemin,pin Singapore 577180 Phone: +65 6319 3450 Fax: *65 6319 3499 apr.securitysystnms@bosch.com www.boschsecurity.com Represented by Bosch Security Systems 2006 I Data subject to change without notice F1331774731 I Cur: en-US, V4, 3 Mar 2006 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. [7272-1615:OTJ Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model(7050) D7050TH and *D705ODH addressable photoelectric type smoke detectors. Model D7050TH employs an integral 1350 fixed temperature heat sensor. This heat sensor is intended for use only as a supplemental device to assist the smoke detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Supplied by Model D7024 series fire alarm control unit through a multiplex bus. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, *date code and UL label. APPROVAL: Listed as photoelectric smoke detectors for use only with listee's separately listed Model D7024 (CSFM Listing No. 7165-1615:147) series fire alarm control unit. Units must be connected to the multiplex bus of the fire alarm control unit for both power and signaling. Model D7050 and D7050TH are intended for use with listee's Model D7050-136 Base (CSFM Listing No. 7300-1615:176). Model D705ODH is intended for use with listee's Model D343 duct detector housing (CSFM Listing No. 3240-1615:181). Rev. 05-29.2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not ~ an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marsha! Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (00-1615:0176) Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: *Mode (50_B63(2 wire) detector base. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed smoke detector base for use with listee's separately listed compatible Models D7050 series smoke detector (CSFM Listing No. 7272-1615:175) and fire alarm control units. Recert. 04-22-2007 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marsha! Fire Engineering Division o BOSCH Invented for life D254/D255 )Fixed-temperature Heat Detector Heads Mounts on low-profile six-inch diameter base Easy head removal for cleaning and servicing Available in 135°F (57°C) or 190°F (88°C) fixed settings Optional latching alarm LED Tamper-resistant locking base Smooth ceiling rating of 2500 ft2 (232 m2) Mechanical heat sensor Use these detectors for indoor confined areas where a fire increases air temperature slowly and where there is a substantial increase in air temperature before the fire breaks confinement. Furnace rooms, closets, bathrooms, and other confined areas are appropriate applications for fixed temperature detectors. Note These heat detectors are intended for detection circuits that protect property. Use smoke detectors to protect personnel. Use the D254 (response-rated at 135°F [57°C]) in areas where the ambient temperatures do not exceed 100°F (381C). Use the D255 (response-rated at 190°F [880C]) in areas where the ambient temperatures do not exceed 150°F (660C). The D254 and(D255.Fixed Temperature Heat Detectors operate in 12 and 24 VDC detection circuits using a variety of Bosch detector bases. A latching steady-on LED is available when these heads are used with the D253 24 VDC base or the D271S 12 VDC base. [Functions Detector Head and Base System These heat detectors have two components: the detector base and the detector head. The bases are permanently attached and wired to back boxes. The interchangeable heads quickly detach for replacement and cleaning without affecting the circuit wiring. Detection Method These heat detectors use a push-rod activated by a bi-metal disk to manually close internal contacts and initiate an alarm condition. The disk, which deflects at a pre-determined temperature, snaps back to its original shape when the temperature drops, opening the contacts and canceling the alarm signal. This simple design results in stable detectors that are dependable and have a long operational life. They are unaffected by barometric pressure and air flow and remain reliable over a wide range of conditions. www.boschsecurity.com -71 LCertificationS and Approvals Technical Specifications Environmental Considerations Certification USA UL UQGS: Heat -Automatic Fire Detectors (UL521) CSFM 7270-1615: 116 July 2008 NYC-MEA 284-91-E, Vol. II Installation/Configuration Notes Compatible Products The following products are compatible with the D254 and D255 Heat Detector Heads: Category Product ID Product Description Control Panels D7022 Conventional FACP 07024 Conventional FACP 07024 Addressable FACP 09124 Addressable FACP Detector Bases D250A Two-wire conventional detector base (12 VDC or 24 VDC) 0253 Two-wire conventional detector base (24 VDC) D27 1S Addressable smoke and heat detector base (12 VDC) D291M Master addressable detector base (24 VDC) D29 1S Addressable detector base (24 VDC) Mounting The detector base installs over a back box and contains all the wiring. The detector head attaches to the base by hand. Align the head with the base and turn it clockwise. No tools are required for installation other than the hex key used to tighten the tamper screw. Wiring Refer to the installation instructions for the specific base for detailed wiring requirements. Temperature 0254: +32°F to +100°F (0°C to +38°C) (ambient): D255: +32°F to +150°F (0°C to +66°C) Mechanical Properties Color: Bone white Dimensions (diameter x D): 6 in. x 2 in. (15.2 cm x 5cm) Response Time: <120sec Power Requirements Voltage (operating): 12 VDC or 24 VDC LOrdering Information D254 Fixed-temperature (135°F [57°CJ) D254 Heat Detector Head Fixed-temperature (135°F [5 7°C]) mechani- cal heat detector head for use in 12 VDC or 24 VDC nominal circuits; requires a base. Ø255 Fixed.temperature(19O0F8Cfl [eat Detector Head)_________ Fixed temperature (190'F [88 cal heat detector head for use in 12 VDC or 24 VDC nominal dirtuits; reuirsa bases [Parts Included Quant. Component 1 D254 or 0255 detector head 1 Hardware pack 1 Literature pack Americas: Bosch Security Systems. Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: *1 800 289 0096 Fax: *1 585 223 9180 security.sales@usbosch.com wwwboschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Boo 80002 5600 JO Eindhoven, The Netherlands Phone: 3140 2577 284 Fax: +3140 2577 330 emea.secsriiysystems@bosch.com www.boschsecurity.com Asia-Pacific: Represented by Robert Bosch ISEA) Pte Ltd. Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: +65 6571 2698 apr.securitysystems@bosch.com www.boschsecarity.com C Bosch Security Systems Inc. 2010 I Data subject to change without notice T1474428043 I Cur: en-US, VS. 4 Jul 2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: APPROVAL: XLF: (7270-1615:0116] Page 1 of I 7270 -- HEAT DETECTOR BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com Model D254 andp2 heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, temperature rating and UL label. Listed as a system heat detector for use with Models D250 and D253 bases (CSFM Listing No. 7300-1615:115) and separately listed compatible control units. [eJJfl[e] 01-04-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: BOSCH SECURITY SYSTEMSI30 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.woIski@us.bosch.com DESIGN: Models D250A,I31)261A, D261 W, D261AW, D270, D280, D280A, D290, D321 and D336A detector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible smoke and heat detectors and fire alarm control units. NOTE: Combined 7300-0801:124 & 128 into 7300-0801:114 XLF: 7300-0410:0132 01-04-2005KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Invented for life D7052 Multiplex Dual-input Module Use with D7024, DS9400M, or FPD-7024 Addressable FACPs Fits into a standard double-gang or four-inch square back box Easy addressing using rotary switches Low current draw UL Listed The(D7052)Multiplex Dual-input Module connects normally-open (NO) contacts to the multiplex bus of a D7024, DS9400M, or FPD-7024 Addressable Fire Alarm Control Panel (FACP). Use the D7052 for two Class B (Style B) supervised inputs or one Class A (Style D) input. All operating power for the input module is drawn from the FACP. Note The D7024 and DS9400M are not listed under UL864, 9th edition. Rotary switches allow convenient address setting. An on-board status LED on the module indicates normal, alarm, and trouble conditions and is visible on the module or on an attractive, low-profile faceplate. [Certifications and Approvals Region Certification USA UL UL864, 9th edition FM CSFM 7165-1615: 147 7165-1615:227 NYC-MEA 12-92-E, Vol. 14 [Installation/Configuration Notes Compatible Products The following products are compatible with the D7052 Multiplex Dual-input Module: Category Product ID Product Description Control D7024 Addressable FACP Panels D7024-EXP Addressable FACP for export DS9400M Addressable FACP FPD-7024 Addressable FACP Modules D7039 Multiplex expansion module Mounting Mount the D7052 on a dou ble-gang or fou r-i nch square back box. Wiring Make connections to the terminals on the rear of the D7052. All terminals can accommodate up to 12 AWG (2.3 mm) wire; however, follow wiring guidelines specified by the National Electrical Code (NFPA-70). All wiring is power limited and supervised. Note Do not use shielded wire. Note Supervise Class B input loops with the supplied EOL resistors. A Class A loop does not require an EOL resistor. www.boschsecurity.com 2 I p7052 Multiplex Dual-input Module [—Parts Included Quant. Component 1 D7052 module 2 2.21 kf) end-of-line (EOL) resistors (P/N: 25899) 1 Literature pack 1 Hardware pack Technical Specifications Circuit Designation MUX Bus: Supervised Class A (Style 6) SLC or Class B (Style 4) SLC Input: Supervised Class A (Style D) IDC or Class B (Style B) IDC Environmental Considerations Environment: Indoor, dry Relative Humidity: Up to 93% non-condensing Temperature (operating): +32°F to + 120°F (0°C to +49°C) Inputs Type: Two normally-open (NO) Class B (Style B) contact inputs or one Class A (Style D) contact input supervised by a 2.21 kf) EOL resistor (P/N: 25899) Mechanical Properties Color: White Dimensions: 4.3125 in. (10.9 cm) square by 1.0625 in. (2.7 cm) deep Material: ABS plastic Weight: 3.9oz(110g) Power Requirements (supplied from FACP's MUX bus) Current: 1Q55 mA) Voltage (minimum): 8 V peak (12 VDC nominal) Ordering Information D7052 Multiplex Dual-input Modit 1D7052) Connects normally-open (NO) contacts to7t7he multiplex bus of a D7024, DS9400M. ) FPD-7024 Addressable FACPJ Amerlcos Europe, Middle East, Africa: Asia-Pacific: Represented by Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd. Security Systems 30 Perinton Parkway P.O. Boo 80002 11 Bishan Street 21 Fairport, New Turk, 14450. USA 5600 JS Eindhoven, The Netherlands Singapore 573943 Phone: *1800289 0096 Phone: * 31402577 284 Phone: +65 6258 5511 Fan: +1585 223 9180 Fuo: *31 40 2577 330 Fax: +65 6571 2698 security.saIes@us.bosch.com ernoa.sncuritysystems@bosch.com apr.securitysystems@bosch.com www.boschsecurlty.us www.boschsecurity.com www.boschsecurlty.com O Bosch Security Systems inc. 2010 Data subject to change without notice T1312455947 ) Cur: en-US. V6, 4 Jul 2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I KAUiLa _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. t1651615i147 Page 1 of 2 CATEGORY: 7165— FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model D7024 fire alarm control unit. Power limited, local, automatic, manual, noncoded, remote station, central station, waterfiow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: D7024; Control Unit 07034; 4-Zone Expander D7033; Keypad D7035, D7035B; Expanded Relay Module 25899; End-of-line Resistor 0184A; City Tie Kit D185; Reverse Polarity Module D7014; Class A Adapter 07039; MUX Expander D7038; Remote NAC Expander D7015; Class A NAC Module D7042; Eight Zone Expander D7042B,(b04A D7044M ,1D7052jMultiplex Expander Module D7048, D7048B; Octal Driver Module (MuItiplex Input/Output Module RATING: 120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 8th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum 07-05-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ' the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Listing No. 7165-1615:0147 Page 2 of 2 Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly 7165-0801:177 07-05-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Invented for life (7O44M Multiplex Mini Single-input Module HUNDREDS TENS .ES. Use with D7024, DS9400M, or FPD-7024 Addressable FACPs Fits into a standard single-gang back box Easy addressing using rotary switches Low current draw UL Listed The Multiplex Mini Single-input Module connects Category Product ID Product Description a normally-open (NO) contact to the multiplex bus of a Control D7024 Addressable FACP D7024, DS9400M or FPD-7024 Addressable Fire Alarm Panels Control Panel (FACP). Use the D7044M supervised input in D7024-EXP Addressable FACP for export a Class B configuration. All operating power for the input DS9400M Addressable FACP module is drawn from the FACP. FPD-7024 Addressable FACP Rotary switches allow convenient address setting. Modules D7039 Multiplex expansion module Note The D7024 is not listed under UL864, 9th Mounting edition. The D7044M fits in a single-gang back box to which the device it is monitoring is attached. Wiring [Connections Certifications and Approvals for the D7044M are made using the 16 AWG (1.5 mm) flying leads from the device. All wiring is power limited and supervised. Region Certification USA UL UL864, 9th edition Note Do not use shielded wire. FM Note Supervise the input loop with the supplied EOL CSFM 7165-1615:147 resistor. 7165-1615:227 NYC-MEA 12-92-E, Vol. 14 Parts Included Quant. Component [Instal lation/Configuration Notes 1 D7044M module Compatible Products 1 2.21 kUend-of-line(EOL) resistor (P/N: 25899) The following products are compatible with the D7044 1 Literature pack Multiplex Single-input Module: www.boschsecurity.com 2 I P7044M Multiplex Mini Single-input Module Technical Specifications Circuit Designation MUX Bus: Supervised Class A (Style 6) SLC or Class B (Style 4) SLC Input: Supervised Class B (Style B) IDC Environmental Considerations Environment: Indoor Relative Humidity: Up to 93% non-condensing Temperature (operating): +32°F to + 120°F (0°C to +49°C) Input Type: One normally-open (NO) contact input supervised by a 2.21 ko EOL resistor (P/N: 25899). Mechanical Properties Color: White Dimensions (HxWxD): 1.5625 in. x 2.75 in. x 0.6875 in. (4 cm x 7 c x 1.75 cm) Material: ABS plastic Weight: 2.902(82 g) Power Requirements (supplied from FACP's MLIX bus) Current: (0.55 Voltage (minimum): 8 V peak (12 VDC nominal) Ordering Information CRT944M_Multiplex Mini Single-input duk)_________ (Connects a normally-open (ö) contact, multiplex bus of a D7024. DS9400Mo tftD-7024 Addressable FACe Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1800 289 0096 Fan: +1 085 223 9180 security.sales@us.bosch.com www.boschsecurlty.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. 000 80002 5600 JB Elndhonen, The Netherlands Phone: u 3140 2577 284 Fan: +3140 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific: Represented by Robert Bosch (SEA) Ftc Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: *65 6298 5511 Fan: *65 6571 2698 apr.securitysystems@bnsch.com www.boschsecurity.com C Bosch Security Systems Inc. 2010 I Data subject to change without notice 71312435979 I Cur: en-US, V6, 4 Jul 2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7165-16150147) Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Model D7024 fire alarm control unit. Power limited, local, automatic, manual, noncoded, remote station, central station, waterfiow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: D7024; Control Unit D7034; 4-Zone Expander D7033; Keypad D7035, D7035B; Expanded Relay Module 25899; End-of-line Resistor 0184A; City Tie Kit D185; Reverse Polarity Module D7014; Class A Adapter D7039; MUX Expander D7038; Remote NAC Expander D7015; Class A NAC Module D7042; Eight Zone Expander D7042B,lD7044 D7044M,(D7052)Multiplex Expander Module D7048, D704813; Octal Driver Module (D7053)Multiplex Input/Output Module RATING: 120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 8th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum 07-05-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ' the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marsha! Fire Engineering Division Listing No. 7165-1615:0147 Page 20f2 Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly 7165-0801:177 07-05-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marsha! Fire Engineering Division o BOSCH Invented for life (D7053)Multiplex Input-output Module Use with D7024, DS9400M, or FPD-7024 Addressable FACPs Fits into a standard double-gang or four-inch square back box Easy addressing using rotary switches Low current draw UL Listed ep Ll The73)Multiplex Input-output Module is a general purpose device that monitors a normally-open (No), supervised contact device and provides a separately controlled Form C relay output. The D7053 connects to the multiplex bus in either a Class A (Style 6) or Class B (Style 4) configuration. All operating power for the D7053 module is drawn from the control panel's multiplex bus. Rotary switches allow convenient address setting. An on- board status LED on the module indicates normal, alarm, and trouble conditions and is visible on the module or on an attractive, low-profile faceplate. Note The D7024 and DS9400M are not listed under UL864, 9th edition. Certifications -and Approvals Region Certification USA UL UL864, 9th edition FM CSFM 7165-1615: 147 7165-1615:227 NYC-MEA 12-92-E, Vol. 14 [istallation/Configuration Notes Compatible Products The following products are compatible with the D7053 Multiplex Input-output Module: Category Product ID Product Description Control D7024 Addressable FACP Panels D7024-EXP Addressable FACP for export DS9400M Addressable FACP FPD-7024 Addressable FACP Modules D7039 Multiplex expansion module Mounting Mount the D7053 on a double-gang or four-inch square back box. Wiring Make connections to the terminals on the rear of the D7053. All terminals can accommodate up to 12 AWG (2.3 mm) wire; however, follow wiring guidelines specified by the National Electrical Code (NFPA-70). All wiring is power limited and supervised. Note Do not use shielded wire. Supervise the Class B input loop with the supplied EOL resistor. www.boschsecurity.com 2 7053 Multiplex Input-output Module [Parts Included Quant. Component 1 D7053 module 2.21 kf) end-of-line (EOL) resistor (P/N: 25899) Literature pack Technical Specifications Circuit Designation MUX Bus: Supervised Class A (Style 6) SLC or Class B (Style 4) SLC Input: Supervised Class B (Style B) IDC Environmental Considerations Environment: Indoor. d Radio Frequency Interfer- No setup or alarm on critical frequencies in ence (RFl) Immunity: the range from 26 MHz to 950 MHz for field strengths less than 30 V/rn Relative Humidity: Up to 93% non-condensing Temperature (operating): +32°F to +120°F (0°C to +49°C) Inputs Type: One normally-open (NO) Class B (Style B) contact input super- vised by a 2.21 kO EOL resistor (P/N 25899). Mechanical Properties Color: White Dimensions: 4.3125 in. (10.9 cm) square by 1.0625 in. (2.7 cm) deep Material: ABS plastic Weight: 3.90z(110g) Outputs Alarm: Reports alarm and point number to FACP Relay: One set of Form C (NO/C/NC) contacts rated for 120 VAC at 0.5 A, 24 VDC at 1.0 A, resistive loads only Trouble: Reports trouble and point number to FACP Power Requirements (supplied from FACP's MUX bus) Current: Voltage (minimum): 8 V peak (12 VDC nominal) Ordering Information 7O53 Muitipleilnpüt-oüiput Module (D7053) Monitors a. normal oei (NO), supervised) contact device and pi'o°'vies a separately con- t Form C Iaiou'tput Y Americas: Bosch Security Systems. Inc. 130 FermIon Pathway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 2239180 security.salos@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Boo 80002 5600 JB Elndhouen, The Netherlands Phone: * 3140 2577 284 Fax: 3140 2577 330 omea.socuritysystems@bosch.cum www.boschsecurity.com Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: *65 6258 5511 Fax: +65 6571 2698 apr.socuritysystoms@bosch.com www.boschsecority.com O Bosch Security Systems Inc. 2010 I Data subject to change without notice T1314224907 I Cur: en-US, V6. 4 Jul 2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-16150) Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski©us.bosch.com DESIGN: Model D7024 fire alarm control unit. Power limited, local, automatic, manual, noncoded, remote station, central station, waterfiow and sprinkler supervisory service. Refer to the listee's data sheet for additional components description. System components: D7024; Control Unit D7034; 4-Zone Expander D7033; Keypad D7035, D703513; Expanded Relay Module 25899; End-of-line Resistor D184A; City Tie Kit D185; Reverse Polarity Module D7014; Class A Adapter D7039; MUX Expander D7038; Remote NAC Expander D7015; Class ANAC Module D7042; Eight Zone Expander 07042B,[D7044) D7044M,(b7052)Multiplex Expander Module D7048, D7048B; Octal Driver Module 1O)Multiplex Input/Output Module RATING: 120 VAC primary; 24 VDC Secondary INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as a fire alarm control unit for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 8th Edition Standard. NOTE: 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum 07.05-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Listing No. 7165-1615:0147 Page 2 of 2 Retard/Reset/Restart period shall not exceed 30 seconds. 2. Formerly 7165-0801:177 07-05-05 it This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marsha! Fire Engineering Division o BOSCH Invented for life (FMM-704§)Series Multiplex Addressable Manual Stations Easy addressing with rotary switches Low current draw Key-lock reset Replaceable scored acrylic breakrod option Terminal connections ADA compliant UL Listed The Series Multiplex Manual Stations are UL Listed fire alarm initiating devices that can be connected along with other multiplex devices on the D7039 Multiplex Expansion Module. The FPD-7024 or D7024 Addressable Fire Alarm Control Panel (FACP) supervises the entire multiplex loop, including the FMM-7045 or FMM-7045-D manual stations, for troubles, alarms, and ground fault conditions. Because each manual station occupies only one address on the multiplex bus, it can be addressed for any point within the 9 to 255 range allowed by the multiplex expansion module. These manual stations are generally installed near building exits such as stairways and doors, allowing persons evacuating the building to activate the fire alarm. They have optional scored acrylic breakrods and a pull handle that locks in the activated position, to allow easy identification of alarm activation points. These manual stations are high-quality units constructed entirely of non-toxic materials. They have a low profile and rounded edges to fit most design applications. All components are painted or have plated surfaces to inhibit corrosion. Non-corroding screw terminals are provided for wire connections. They are manufactured in conformance with the standards set forth in the Americans with Disabilities Act (ADA). Functions Alarm Action The single-action FMM-7045 has a white pull-down lever in its center. The dual-action FMM-7045-D has a white push lever above the white pull-down lever in its center. Pulling down the pull-down lever latches it into place and sends an alarm signal to the control panel over the multiplex bus. The pull-down lever cannot be reset unless the correct key is inserted into the manual station's lock and the unit is opened. The latching lever can then be restored to its normal position. Etifications and Approvals Region Certification USA UL UNIU: Boxes, Non-Coded (UL38) CSFM 7150-1615: 122 NYC-MEA 12-92-E, Vol. 14 ADA Complies with Americans with Disabilities Act ADA 4.28.3 NFPA Complies with National Fire Protection As- sociation NFPA 72 www.boschsecurity.com ConfigurationNotes Compatibility Information The FMM-7045 Series Multiplex Manual Stations are compatible with a FPD-7024 FACP or a D7024 FACP with firmware revision 2.0 or greater with a D7039 Multiplex Expansion Module. Addressing Addresses are set using three rotary switches. Refer to the D7024 FACP Operation and Installation Guide (P/N: 31499 or the FPD-7024 Operation and Installation Guide (P/ N F01U008458) and the FMM-7045, FMM-7045-D Multiplex Addressable Manual Stations Installation Instructions (PI N: F01U001402) for programming information. Mounting The FMM-7045 manual stations are for indoor use only. Note If a pull station is needed for outdoor use or in an unheated area, use an FMM-100 Series Pull Station rated for the environment and wired to a multiplex module within the interior of the building. The FMM-7045 manual stations flush or surface mount on a standard four-inch square back box with a single-gang mud ring so that the total depth of the box is at least 2.25 in. (5.7 cm). Note The FMM-7045 does not fit an FMM-100BB-R Back Box. Wiring The terminal block accepts wiring up to 12 AWG (2.3 mm) in diameter. Refer to the D7039 Installation Instructions (PI N: 38685) for multiplex wiring information. [Parts Included Quant. Component 1 Manual station 1 FMM-100GR Scored Acrylic Breakrod Technical Specifications 7 Environmental Considerations Environment: Dry, indoor Radio Frequency No alarm on critical frequencies in the range Interference (RFI) from 26 MHz to 950 MHz at field strengths Immunity: less than 30 V/rn. Temperature (Operating): +32°F to +120'F (0°C to +49°C) Mechanical Properties Dimensions (HxWx D): 4.75 in. x 3.75 in. x3.25 in. (12 cm 9.5 cm 8.2 cm) Material: Die cast zinc alloy and steel Power Requirements Current Draw (Mux Bus (Alarm: 0.55 mAL Average): (Standby.. 0.55 mA) Voltage (Operating): 12 VDC nominal (provided by the MUX bus) Ordering Information I FMM-7045 SijtAction Manual iiio (FMM-7045) A UL Liste5d fire alarm initiating device that c) be connected, along with other multiplex de-) vices, on çhe D7039 Multiplex Expansion ule and is superv1e the FP D7 Addressable FACT) FMM-7045-D Double-Action Manual FMM-7045-D Station A UL Listed fire alarm initiating device that can be connected, along with other multiplex de- vices, on the D7039 Multiplex Expansion Mod- ule and is supervised by the FPD-7024 or D7024 Addressable FACP Accessories D102 Replacement Key D102 Replacement key (#1358) for the D101 lock. FMM-100GR Scored Acrylic Break Rods FMM-100GR Scored acrylic rods (12 per package) 1 D102 Key (1358) 1 Literature pack Americas, Europe, Middle East, Africa: Bosch Security Systems, Inc. Bosch Security Systems B.V. 130 Fermion Parkway P.O. Boo 80002 Fairport, New York, 14450, USA 5600 JB Eindhonen, The Netherlands Phone: -18002890096 Phone: + 3140 2577 284 Fan: +1585 223 9180 Fax: +3140 2677 330 socurity.salos@us.bosch.com omea.securitysystems@bosch,com www.boschsecurlty.us www.boschsecurity.com O Bosch Security Systems Inc. 2010 I Data subject to change without notice T1953041035 I Car: en-US, VS. 4 Jul 2010 Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6258 5511 Fax: *65 6571 2698 apr.necuritysystems@bnsch.com www.boschsecurlty.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: (7150-1615:0122) Page 1 of 1 7150-- FIRE ALARM PULL BOXES BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com Models, FMM462, FMM462-D, FMM-325A, FMM-325A-D (FMM-704) and FMM-7045-D fire alarm manual pull stations. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinance and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as manual pull stations for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. NOTE: FORMERLY: 7150-0801:131 Rev. 12-15-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not ¶,... an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division O BOSCH Invented for life W-HS Series Wall-mount Multi-candela Horn Strobes The Cooper Wheelock Exceder Series Horn Strobes feature a sleek modern design that incorporates high reliability and high-efficiency optics to minimize current draw. The reduced current draw allows for a greater number of devices on the two-wire notification appliance circuit. This, in combination with eight candela options in one appliance, no tools needed for changing settings, voltage test points, 12 V or 24 V DC operation, the universal mounting base, and multiple mounting options results in a reduced cost of ownership. These horn strobes provide eight candela settings and three sound settings on each appliance. All the switches to change these settings can be set without a tool and are located behind the appliance to prevent tampering. The separate universal mounting base can be easily mounted to five industry-standard back box types. They can also be pre-wired to allow full testing of the circuit wiring before the appliance is installed and the surface finished. These wall-mounting horn strobes also feature voltage test points for taking readings with a volt meter for troubleshooting or AHJ inspection. Sleek modern aesthetics Multiple voltages (12 VDC or 24 VDC) Voltage test points Eight strobe candela options and three horn volume options Universal mounting base Environment-friendly low current draw [Certifications and Approvals Certification USA UL ULSZ: Audible-signal Appliances (ANSI/UL 464), UUKC: Signaling Appliances and Equipmentforthe Hearing Impaired (ANSI! UL 1971) CSFM 7125-0785:168 Canada ULC UEESC: Visual and Visual-audible Signal Appliances, Fire Alarm (CAN/ULC-S525, CAN/ULC-S541, CAN/ULC-S526, ULC- S527), ULSZC: Audible Signal Appliances and Accessories, Fire Alarm (CAN/ULC- S525, ULC-S527) Cooper Wheelock has also designed these horn strobes to comply with: US ADA ADAAG Equivalent Facilitation Guidelines ANSI ANSI 117.1 FCC Tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. NEC National Electrical Code NFPA NFPA72 www.boschsecurity.com 2 I W,-HS Series Wall-mount Multi-candela Horn Strobes jtallation/Configuration Notes Compatibility Horn: These horns provide a selectable Continuous or Code 3 horn tone when connected directly to the Fire Alarm Control Panel (FACP). They can also provide a synchronized Code 3 Horn tone when used in conjunction with an FACP that incorporates the Cooper Notification sync protocol, a Cooper Notification Sync Module, or the Cooper Notification Power Supply. The Horn Appliances can be field set for High (HI), Medium (MED), or Low (LO) dBA sound output. Strobe: These strobes provide a non-synchronized strobe appliance when connected directly to a Fire Alarm Control Panel (FACP), or provide a synchronized strobe appliance when used in conjunction with an FACP that incorporates the Cooper Notification sync protocol, a Cooper Notification Sync Module, or the Cooper Notification Power Supply. They are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. Note Strobes are not designed to be used on coded systems in which the applied voltage is cycled on and off. Compatible Products The following Bosch Security Systems, Inc. products are compatible with the Cooper Wheelock Exceder Series Horn Strobes: Category Product ID Product Description Control Panels FPA-1000-uL1 Compact Fire Panel FPD-70241 Conventional or Addressable2 FACP D10024A3 Analog FACP D80243 Analog FACP D91243 Addressable FACP D70243 Conventional or Addressable2 FACP D70223 Conventional FACP Modules SM-12/24-R Synchronization module (red) DSM-12/24-R Dual synchronization module (red) Power Supplies FPP-RNAC-8A-4C1 Remote Notification Appliance Circuit (RNAC) Power Supply PS-24-8MC1 Power supply with built-in syn- chronization protocol 1 These products have built-in Cooper Notification synch protocol. 2 When used with a D7039 Multiplex Expansion Module, the FPD-7024 or the D7024 becomes an addressable FACP. For synchronization, use the SM or DSM modules with these control panels. Mounting Considerations The Universal Mounting Base supplied with each horn strobe can be pre-wired. With the supplied Contact Cover in place, the pre-wired circuit can be checked for continuity before the horn strobes are mounted. The horn strobes snap onto the pre-installed Universal Mounting Bases with the Contact Covers removed and can be secured to the base with an optional securing screw. The Universal Mounting Base flush mounts on single-gang, double-gang, 4 in. square, 4 in. octal, 3.5 in. octal, and 100 mm European-type back boxes. Wiring Considerations The wiring terminals on the Universal Mounting Base accept two appliance wires with diameters between 12 AWG (2.3 mm) and 18 AWG (1.2 mm) at each terminal. [Parts Included Quant. Component 1 Horn Strobe appliance 1 Universal mounting base 1 Contact cover 1 Hardware pack Two pan head mounting screws One securing screw 1 Literature - Installation Instructions Technical Specifications Audible Patterns and Ratings Pattern Volume Sound Output1 Setting 8.0V 12.0V 17.5V Continuous: High: 83 dBa 88 dBa 91 dBa Medium: 79 dBa 82 dBa 86 dBa Low: 72 dBa 76 dBa 79 dBa Code 32: High: 80 dBa 84 dBa 86 dBa Medium 74 dBa 78 dBa 82 dBa Low: 68 dBa 72 dBa 76 dBa 16.0 V 24.0 V 30.0 V Continuous: High: 91 dBa 93 dBa 96 dBa Medium: 86 dBa 89 dBa 92 dBa Low: 78 dBa 82 dBa 85 dBa Code 32: High: 86 d8 89 dBa 91 dBa Medium 81 dBa 85 dBa 84 dBa Low: 74 dBa 78 dBa 80 dBa 1 Sound output is a minimum UL rating based on sound power measurements at a distance of 10 ft (3 m) in a reverberant test room per UL464. 2 The Code 3 temporal pattern (1/2 second on, 1/2 second off, 1/2 second on, 1/2 second off, 1/2 second on, 1-1/2 second off and repeat) is specified by ANSI and NFPA 72 for standard emergency evacuation signaling. Note The Code 3 temporal pattern should be used only for fire evacuation signaling and not for any other purpose. Environmental Considerations Environment: Indoor, dry Relative Humidity: 93±2% maximum, non-condensing Temperature (operating): +32°F to + 120°F (0°C to +49°C) Mechanical Properties Candela Ratings3: 15 cd, 15/75 cd4, 30 cd, 75 cd, 95 cd. 110 cd, 135 cd, or 185 cd Dimensions: 5.24 in. x 4.58 in. x 2.19 in. (133.1 mm x 116.4 mm x 55.7 mm) Material: Molded plastic enclosure incorporating a Xenon flashtube and Lexan lens. Volume Settings: 90db, 95db, or 99 d When set for 12 V operation, strobe devices are only approved by UL to be set at 15cd or 15/75 cd and only to be powered by DC not FWR. Although this product is UL Listed at 15 cd, it provides 75 cd on axis. Power Requirements Horn and Strobe Current Draws 24 V nominal (16.0 V to 33.0 V ranee) Voltage Volume Current Draw Type Setting DC: High: 15 cd: 82 mA, 15/75 cd: 95 mA, 30 cd: 102 mA, 75 cd: 148 mA, 95 cd: 176 mA, 110 cd: 197 mA, 135 cd: 242 mA, 185 cd: 282 mA Medium: 15 cd: 73 mA, 15/75 cd: 83 mA, 30 cd: 87 mA, 75 cd: 139 mA, 95 cd: 163 mA, 110 cd: 186 mA, 135 cd: 230 mA, 185 cd 272 mA Low: cd: 75 mA, 30 cd: 87 mA, 75 cd: 139 mA, 95 cd: 157 mA, 110 cd: 184 mA, 135 cd: 226 mA, 185 cd: 267 mA Horn and Strobe Current Draws FWR: High: 15 cd: 133 mA, 15/75 cd: 138 mA, 30 cd: 138 mA, 75 cd: 216 mA, 95 cd: 258 mA, 110 cd: 289 mA, 135 cd: 357 mA, 185 cd: 384 mA Medium: 15 cd: 112 mA, 15/75 cd: 126 mA, 30 cd: 126 mA, 75 cd: 201 mA, 95 cd: 247 mA, 110 cd: 272 mA, 135 cd: 340 mA, 185 cd: 378 mA Low: 15 cd: 106 mA, 15/75 cd: 120 mA, 30 cd: 120 mA, 75cd: 196 mA, 95cd: 235 mA, 110 cd: 265 mA, 135 cd: 331 mA. 185 cd: 375 mA 12Vnominal (8.0 Vto 17.5Vrange) Voltage Volume Current Draw Type Setting DC: High: 15 cd: 125 mA, 15/75 cd: 159 mA Medium: 15 cd: 122 mA, 15/75 cd: 153 mA Low: 15 cd: 120 mA, 15/75 cd: 148 mA Voltage (input) Regulated Range 12VDC 8.0Vto17.5V 24 VDC or Vrms 16.0 V to 33.0 V Current Draw is the same for the Continuous Horn and Code 3 Horn Settings. Trademarks Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. uses the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringing the trademark. Cooper Notification, Cooper Wheelock, Wheelock and Exceder are either trademarks or registered trademarks of Cooper Wheelock, Inc. which is a division of Cooper Menvier, a Cooper Industries, Ltd. company. Lexan is a registered trademark of General Electric Corporation, USA, in the United States and other countries. Ordering Information W•HSR Wall-mount Multi-candela Horn W-HSR Strobe (two-wire, 12/24 V, red) Rectangular red two-wire horn strobe field-se- lectable for three volume options and eight candela oDtions. (W-HSW) ire,12/V,whI Rectangular white two-wire horn strobe be ( field-selectable for three volume options and) fght candela opsj www.boschsecurity.com Americas Europe, Middle East, Africa: Asia-Pacific; Represented by Bosch Security Systems. Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd. Security Systems 130 Perinton Parkway P.O. Boo 80002 11 Bishan Street 21 Fairport, New York, 14450, USA 5600 .JB Eindhoven, The Netherlands Singapore 573943 Phone: +1800 289 0096 Phone: * 3140 2577 284 Phone: +65 6258 5511 Fax: -1585 223 9180 Fax: +3140 2577 330 Fax: +65 6571 2698 security.sates@usbosch.com emea.secoritysystems@bosch.com apr.securitysystoms@bosch.com wmw.boschsecurily.us www.boschsecurity.com www.boschsecorlty.com Q Bosch Security Systems Inc. 2010 I Data subject to change without notice T6888480011 I Cur: en-US, V2, 4 Jul 2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (125-0785:016i) Page 1 of 1 CATEGORY: 7125 - FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe,lhorn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) orI(white). Additionally, a 'C' may be added for ceiling models and/or a '- NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. Rev. 9-24-09 fm 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Fire Alarm Systems I W-ST Series Wall-mount Multi-candela Strobes 21BOSCH IInvented forlife W-ST Series Wall-mount Multi-candela Strobes Sleek modern aesthetics Multiple voltages (12 VDC or 24 VDC) Voltage test points Eight strobe candela options Universal mounting base Environment-friendly low current draw The Cooper Wheelock Exceder Series Strobes feature a sleek modern design that incorporates high reliability and high-efficiency optics to minimize current draw. The reduced current draw allows for a greater number of devices on the two-wire notification appliance circuit. This, in combination with eight candela options in one appliance, no tools needed for changing settings, voltage test points, 12 V or 24 V DC operation, the universal mounting base, and multiple mounting options results in a reduced cost of ownership. These strobes provide eight candela settings. All the switches to change these settings can be set without a tool and are located behind the appliance to prevent tampering. The separate universal mounting base can be easily mounted to five industry-standard back box types. They can also be pre-wired to allow full testing of the circuit wiring before the appliance is installed and the surface finished. These wall-mounting strobes also feature voltage test points for taking readings with a volt meter for troubleshooting or AHJ inspection. Tcertifications and Approvals Region Certification USA UL UUKC: Signaling Appliances and Equipment for the Hearing Impaired (ANSI/UL 1971), UVAV: Visual-signal Appliances for Fire-protective Signaling Systems (ANSI/UL 1638) CSFM 7125-0785:168 Cooper Wheelock has also designed these strobes to comply with: ADA ADAAG Equivalent Facilitation Guidelines ANSI ANSI 117.1 FCC Tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. NEC National Electrical Code NFPA NFPA72 [Installation/Configuration Notes Compatibility Strobe: www.boschsecurity.com These strobes provide a non-synchronized strobe appliance when connected directly to a Fire Alarm Control Panel (FACP), or provide a synchronized strobe appliance when used in conjunction with an FACP that incorporates the Cooper Notification sync protocol, a Cooper Notification Sync Module, or the Cooper Notification Power Supply. They are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. Base flush mounts on single-gang, double-gang, 4 in. square, 4 in. octal, 3.5 in. octal and 100 mm European- type back boxes. Wiring Considerations The wiring terminals on the Universal Mounting Base accept two appliance wires with diameters between 12 AWG (2.3 mm) and 18 AWG (1.2 mm) at each terminal. Note Strobes are not designed to be used on coded systems in which the applied voltage is Parts Included cycled on and off. Compatible Products The following Bosch Security Systems, Inc. products are compatible with the Cooper Wheelock Exceder Series Strobes: Category Product ID Product Description Control Panels FPA-1000-UL1 Compact Fire Panel FPD-70241 Conventional or Addressable2 FACP D10024A3 Analog FACP D80243 Analog FACP D91243 Addressable FACP D70243 Conventional or Addressable2 FACP D70223 Conventional FACP Modules SM-12/24-R Synchronization module (red) DSM-12/24-R Dual synchronization module (red) Power Supplies FPP-RNAC-8A-4C1 Remote Notification Appliance Circuit (RNAC) Power Supply PS-24-8MC' Power supply with built-in synchronization protocol 1 These products have built-in Cooper Notification synch protocol. 2 When used with a D7039 Multiplex Expansion Module, the FPD-7024 or the D7024 becomes an addressable FACP. For synchronization, use the SM or DSM modules with these control panels. Mounting Considerations The Universal Mounting Base supplied with each strobe can be pre-wired. With the supplied Contact Cover in place, the pre-wired circuit can be checked for continuity before the strobes are mounted. The strobes snap onto the pre-installed Universal Mounting Bases with the Contact Covers removed and can be secured to the base with an optional securing screw. The Universal Mounting Quant. Component 1 Strobe appliance 1 Universal mounting base 1 Contact cover 1 Hardware pack Two pan head mounting screws One securing screw 1 Literature - Installation Instructions [Technical Specifications Environmental Considerations Environment: Indoor, dry Relative Humidity: 93±2% maximum, non-condensing Temperature (operating): +32°F to +120°F (0°C to +49°C) Mechanical Properties Candela Ratings1: 15 cd. 15/75 cd2, 30 cd, 75 cd, 95 cd, 110 cd, 135 cd, or 185 cd Dimensions: 5.24 in. x 4.58 in. x 2.19 in. (133.1 mm x 116.4 mm x 55.7 mm) Material: Molded plastic enclosure incorporating a Xenon flashtube and Lexan lens. 1 When set for 12 V operationstrobe devices are only approved by UL to be set at 15cd or 15/75 cd and only to be powered by DC not FWR. 2 Although this product is UL Listed at 15 cd, it provides 75 cd on axis. W-ST Series Wall-mount Multi-candela Strobes 1 3 Power Requirements Strobe Current Draw 24 V nominal (16.0 V to 33.0 V range) Voltage Current Draw Type DC/FWR: (15 cd: 57 mA 15/75 cd: 70 mA, 30 cd: 85 mA, 75 cd 135 mA, 95 cd: 163 mA, 110 cd: 182 mA, 135 cd: 205 mA, 185 cd: 253 mA 12 V nominal (8.0 Vto 17.5 V range) Voltage Current Draw DC: 15 cd: 110 mA, 15/75 cd: 140 mA Voltage (input) Regulated Range 12VDC 8.0Vto17.5V 24VDCorVrms 16.0Vto33.0V Trademarks Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. uses the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringing the trademark. Cooper Notification, Cooper Wheelock, Wheelock and Exceder are either trademarks or registered trademarks of Cooper Wheelock, Inc. which is a division of Cooper Menvier, a Cooper Industries, Ltd. company. Lexan is a registered trademark of General Electric Corporation, USA, in the United States and other countries. LOrdering Information W-STR Wall-mount Multi-candela Strobe W-STR (two-wire, 12/24 V, red) Rectangular red two-wire strobe that is field-selectable for eight candela ootions. (WSTW Wall-mount Milii-candela jire, 12/24 V, white)) Rectangular white two-wire siht1 jfield-selectable for eight candela op) www.boschsecurity.com 4 I W-ST Series Wall-mount Multi-candela Strobes Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JO Eindhoven, The Netherlands Phone:o 3140 2577 284 Fax: -3140 2577 330 emea.securitysystems@bosch.com www.boschsecurlty.com Asia-Pacific: Robert Bosch (SEA) Pte Ltd. Security Systems 11 Bishan Street 21 Singapore 573943 Phone: *65 6258 5511 Fax: *65 6571 2698 apr.securitysystems@bosch.com www.boschsecurity.asia Represented by O Bosch Security Systems 20111 Data subject to change without notice T6889056011 I Cur: en-US, V3, 1 Jul 2011 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (71 25-0785:0168 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover©cooperindustries.com DESIGN: Exceder Series: Models ST strobe,horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or(white). Additionally, a 'C' may be added for ceiling models and/or a -NR' may be added for non-resettable models. For non -NR models and optional S' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marsha! Fire Engineering Division O BOSCH Invented for life MIZ Series Piezoelectric Mini-horns These Wheelock mini-horns are dual-tone alarm devices listed for indoor use under UL464 for Audible Appliances. They combine a low current draw for a high sound output and offer field-selectable tone settings for temporal (Code 3) or continuous horn tones. They use either filtered DC or unfiltered full wave rectified (FWR) input voltage. All inputs are polarized for standard reverse polarity supervision. They can be synchronized when used with the SM (single) and DSM (dual) Synchronization Modules or a compatible control panel. If not synchronized, the temporal sound patterns could overlap and not be distinctive. Available in red for high visibility or off-white to blend in with room decor, these notification appliances offer the durability of high impact thermoplastic construction, easy installation through two-wire circuitry and single-gang box compatibility. They are ideal audible notification appliances for signaling alarms in individual rooms in apartments, hotels, motels, and offices. ECertifications and Approvals Cooper Wheelock, Inc. holds these Listings and Approvals: Operates on 24 VDC, filtered or unfiltered Field-selectable settings for temporal (Code 3) or continuous horn High sound output (90 dBA at 10 ft [3 m]) Low current draw on two-wire loop Low temperature compensation Designed to meet or exceed NFPA/ANSI standards Convenient mounting on any standard single-gang box Flush or surface mounting options Certification USA UL UCST: Audible Signal Appliances, General Siganal (UL464), ULSZ: Audible Signal Appliances (UL464) FM CSFM 7135-0785: 115 and 7135-0785: 150 ULC-5525-99: Canadian UL Standard for Audible Signal Appliances for Fire Alarm Systems City of Chicago Bureau of Fire Protection NYC/MEA(151-92-E, Vol. 39) Complies with: American National Standards Institute (ANSI) National Fire Protection Association (NFPA) [istallation/Configuration Notes 1 Compatible Products The following products are compatible with the MIZ Series Mini-horns: 0 www.boschsecurity.com Category Product ID Product Description Control FPA-1000-UL Compact Fire Panel Panels FPD-70241 Addressable FACP FPD-7024 Conventional FACP D7024' Addressable FACP D7024 Conventional FACP D80242 Analog FACP D91242 Addressable FACP D10024A2 Analog FACP Modules SM-12/24-R Single synchronization module (red) DSM-12/24-R Dual synchronization module (red) 1 When used with a D7039 Multiplex Expansion Module, the FPD-7024 or D7024 becomes an addressable fire alarm control panel (FACP). 2 For synchronization, use the SM or DSM Synchronization Modules with these control panels. Mounting Considerations Mount these mini-horns on the indicated back boxes for the indicated applications: Conduit Surface Flush Applications Mounted Mounted Single-gang, wiremold Single-gang, deep Wiring The input terminals accept wires with diameters between 18 AWG (1.2 mm) and 12 AWG (2.3 mm). [Parts Included 1 Quant. Component 1 MIZ-245-R or MlZ-245-W Mini-horn 1 Hardware pack 1 Literature pack Mechanical Properties Dimensions (H x W x D): 4.5 in. x 2.75 in. x 1.375 in. (11.4 cm 7.0 cm 3.5 cm) Material: High-impact thermoplastic Power Requirements Maximum Horn Current (RMS, (VDC: 26 mA) operating): FWR: 43 mA Voltage (nominal input): 24 VDC or FWR Voltage (operating range): 16 V to 33 VDC or FWR Sound Output (UL Reverberant Room) at loft (3m) Continuous: 16 VDC: 79 dBA 24 VDC: 83dBA 33 VDC: 85 dBA Temporal (Code 3): 16 VDC: 75 dBA 24 VDC: 78 dBA 33 VDC: 81 dBA Note The sound output for the temporal Code 3 is lower than in Continuous mode because the time that the horn is off is averaged into the sound output rating. While the horn is producing a tone in temporal Code 3 modes, its sound pressure is the same as the Continuous mode. Ordering Information MIZ-245-R 24 V Mini-horn (red) MIZ-24S-R Red, 24 VDC dual-tone alarm device with low current draw, high sound output, and field-se- lectable settings for temporal (Code 3) or con- tinuous horn tones tMlZ-245W 24 V Miiihiii(hite) lZ-24S) White, 24 VDC dual-tone alarm device withi current draw, high sound output, and field-se- lectable settings for temporal (Code 3) or con- juous horn toneP [Technical Specifications Environmental Considerations Relative Humidity: Up to 93%, non-condensing Temperature (Operating): +32°F to +120°F (0°C to +49°C) Americas, Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone, 01800 289 0096 Fax: +1585 223 9180 securlty.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa, Bosch Security Systems B.V. P.O. 800 80002 5600 JR Eindhooen, The Netherlands Phone, * 3140 2577 284 Fan: +3140 2077 330 emea.securitysystems@bosch.com www.boschsecurlty.com Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 073943 Phone: *65 6208 5511 Fax: +65 6571 2698 apr.secaritysystems@bosch.com www.boschsecurity.com C Bosch Security Systems Inc. 2010 I Data subject to change without notice T1121702539 I Cur, en-US, VS. 4 Jul 2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7135-07850150 Page 1 of 1 CATEGORY: 7135 —AUDIBLE DEVICES LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Models MIZ-12S, and MIZ-245 electronic horns. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: MlZ-12S = 12V Nominal, 8-17.5V DC, 17mAmax. [Mlz-24= 24V Nominal, 16-33V DC, 24mAmax. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. For indoor use only. Models MIZ-125 and MlZ-245 are suitable for synchronization when used in conjunction with Models *sM..12/24 SMX-12/24, DSM-12/24, DSMX-12/24 (CSFM Listing No. 7300-0785:132) Sync Control Modules. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: *Rev 8-21-09 FM This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not . an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marsha! Fire Engineering Division o BOSCH Invented for life (D370)Series Wall-mount Door Holders LL4 ThD370)Series electromagnetic door holders are rugged die-cast devices for holding doors. These electromagnetic door holders allow control of doorways in alarm conditions. Typical applications are in stairways or other exit pathways where it is desirable to restrict airflow yet allow free emergency access. Functions Power and Holding Force The D370 Series door holders accept power from 24 VAC, 24 VDC, or 120 VAC sources. Depending on how they are wired and the amount of current, they can supply from 35 lb to 110 lb of holding force. Certifications and Approvals Region Certification USA UL SZNT: Releasing Devices, Ordinary Locations (UL864) CSFM 3550-1615:164 Hong Kong HKFSD Attractive design, sturdy cast construction with brass (B) or metallic powder-coat (C) finish 24 VAC, 24 VDC, or 120 VAC 12 AWG (2.3 mm) to 22 AWG (0.8 mm) terminals Holding force between 35 lb and 110 lb A variety of available extension rods allow mounting in difficult locations Wall-mount using standard single-gang back boxes or surface-mount using D372B and D372C back boxes [Installation/Configuration Notes J Mounting Considerations The D370B (brass) and D370C (metallic powder-coat) holders are for wall-mounted applications and can be flush-mounted on standard single-gang back boxes or surface-mounted on the D372B and D372C back boxes. The D372 back boxes complement the finish of the D370 electromagnet component that mounts in them. Extension rods are available in lengths from 1 in. (2.5 cm) to 4 in. (10 cm) to allow installation in applications where the door does not swing to within 3 in. (7.5 cm) of the back box. Wiring Considerations Wire the D370B (brass) and D370C (metallic powder-coat) holders through knockouts in the back or the sides of the back boxes. The terminals accept wires from 12 AWG (2.3 mm) to 22 AWG (0.8 mm). www.boschsecurity.com [Parts Included —71 Quant. Component 1 Door magnet 1 Catch plate 1 Nut plate 1 Mounting template 1 Hardware pack 1 Literature pack [Technical Specifications Environmental Considerations Relative Humidity: Up to 95%, non-condensing Temperature (operating) +32°F to + 120°F (0°C to +49°C) Mechanical Properties Dimensions Catch Plate (diameter x depth)': 2.25 in. X 2.25 in. (5.7 cm 5.7 cm) Electromagnet (H x W x D)2: 4.625 in. x 2.75 in. x 2 in. (11.7 cm 7 c x 5.1 cm) 1 The diameter of the magnet plate is 1.75 in. (4.4 cm). 2 The electromagnet component extends 0.875 in (2.2 cm) from the mounting surface when surface mounted. It extends 1.125 in. (2.9 cm) into the back box. Power Requirements Current Draw (24 V installations) 24 VAC: 19 mA 4vDc Current Draw (120 V installations) Common and High 20 mA Voltaee Terminals: Common and Low 100 mA Voltage Terminals: Voltage (supply): 24 VAC, 24 VDC, or 120 VAC Ordering Information D370B Wall-Mount Door Holder with Brass D370B Finish Door holder with brass finish accepts power from 24VAC, 24 VDC, or 120 VACsourcesand, depending on wiring and current, can supply from 35 lb to 110 lb of holding force 'OC Wall-Mount Door Holder with (D370c c Powder-coat Finish holder with metallic powder-coat fiJ pts power from 24 VAC, 24 VDC, orL VAC sources and, depending on wirin) current, can supplyfrom 35 lb to 110 lb of) D372B Surface-mount Back Box (brass) D372B Brass-dated metal surface-mount back box D372C Surface-mount Back Box (metallic D372C powder-coat) metal surface-mount back box with metallic powder-coat finish D373B Extension Rod (brass, 2.5 cm [1 in.]) D373B 2.5 cm (1 in.) extension rod with brass finish; package of five D373C Extension Rod (metallic D373C powder-coat, 2.5 cm 11 in.]) 2.5 cm (1 in.) extension rod with metallic pow- der-coat finish; package of five D374B Extension Rod (brass, 3.8 cm D374B [1.5 in.]) 3.8 cm (1.5 in.) extension rod with brass fin- ish; package of five D374C Extension Rod (metallic D374C powder-coat, 3.8 cm [1.5 in.]) 3.8 cm (1.5 in.) extension rod with metalliic powder-coat finish.; package of five D375B Extension Rod (brass, 5.1 cm 12 in.]) D375B 5.1cm (2 in.) extension rod with brass finish; package of five D375C Extension Rod (metallic D375C powder-coat, 5.1 cm 12 in.]) 5.1cm (2 in.) extension rod with metallic pow- der-coat finish; package of five D376B Extension Rod (brass, 7.6cm [3 in.]) D376B 7.6 cm (3 in.) extension rod with brass finish; package of five D376C Extension Rod (metallic D376C powder-coat, 7.6 cm 13 in.]) 7.6 cm (3 in.) extension rod with metallic pow- der-coat finish; package of five D377B Extension Rod (brass, 10.2 cm D377B 14 in.]) 10.2 cm (4 in.) extension rod with brassfinish; package of five [Ordering Information D377C Extension Rod (metallic D377C powder-coat, 10.2 cm (4 in.]) 10.2 cm (4 in.) extension rod with metallic powder-coat finish; package of five D378 Extension Rod Wrench Kit D378 Wrench kit for installing extension rods and door holders D379 Swivel-Base Mounting Drill Fixture D379 Fixture for locating and drilling a through hole for mounting a magnetic door holderon a door. www.boschsecurity.com 4 16),370 Series Wall-mount Door Holders Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450. USA Phone: +1800 289 0096 Fax: +1585 223 9180 socurity.saIes@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Boo 80002 5600 JB Eindhoven, The Netherlands Phone: * 3140 2577 284 Fax: +3140 2577 330 emea.socuritysystems@bosch.com www.boschsecurity.com Asia-Pacific: Represented by Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: 065 6258 5511 Fax: *65 6571 2698 apr.securitysystems@bosch.com www.beschsecurity.com Bosch Security Systems Inc. 20101 Data subject to change without notice T287B263179 (Cur: en-US, V5, 4 Jul 2010 ir CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3550-16150164) Page 1 of 1 CATEGORY: 3550 -- DOOR CLOSER/HOLDERS/RELEASING DEVICES LISTEE: BOSCH SECURITY SYSTEMS130 Perinton Parkway, Fairport, NY 14450 Contact: Jon Wolski (585) 678-3323 Fax (585) 678-3263 Email: jon.wolski@us.bosch.com DESIGN: Models D370BfD370C D371 B, D371 C, D372B, D372C door closer/holders. Refer to listee's data sheet for additional detailed product description and operational consideration RATING: 24V AC/DC, 110VAC INSTALLATION: In accordance with listee's printed installation instructions and applicable codes and ordinances. The unit is intended to be mounted in a horizontal position only. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as door closer/holders for use with separately listed compatible detectors and fire alarm control units. XLF: 3550-1039:0100 01-04-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division