Loading...
HomeMy WebLinkAbout5545 FERMI CT; ; FPC2018-0117; Permit4bty of PERMIT REPORT. Carlsbad Print Da te: 10/20/2021 Permit No: FPC2018-0117 Job Address: 5545 FERMI CT, CARLSBAD, CA 92008-7324 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2121303700 Track #: Applied: 04/23/2018 Valuation: $339,802.06 Lot #: Issued: 05/04/2018 Occupancy Group: Project #: Finaled Close Out: 10/20/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: TAYLORMADE -ALARM TI (PHASE 3) Applicant: FPContractor: JJJ ENTERPRISES . THE STEINHILBER CORPORATION SALOMON GOMEZ 533 S VINEWOOD ST 115 MARKET PL . ESCONDIDO, CA 92029-1924 ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 (760) 747-3050 x216 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov mriplop EHUFFpnom FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS TAYLOR MADE PHASE 3- OFFICE RENOVATION 5545 FERMI COURT CARLSBAD, CA 92008 FIRE ALARM SYSTEM MATERIAL1DATA SHEETS Al P V-Plex is the patented polling loop technology that literally defines price and performance on a simple pair of wires. By using two wires instead of four, V-Flex offers significant advantages over home run wing or the conventional four-wire multiplex—providing economical expansion of peripheral devices and point identification to your central monitoring station. 11 ir:I THE INDUSTRY'S LEADING ADDRESSABLE TECHNOLOGY Benefits Reduced Costs Since each V-Flex sensor can be installed using two wires for power and data—including existing wiring in many cases—costs are substantially reduced. Reduced Power Consumption V-Plex devices draw minimal amounts of current, minimizing the need for auxiliary power supplies. Fast, Accurate Identification and Response Point ID allows you to quickly and easily pinpoint the source of alarm or trouble from the keypad and communicate the information to the proper authorities—and lets you bypass protection at any specific point. Reduced Time and Labor V-Flex offers a labor and time-saving maintenance feature that gives you the ability to diagnose and pinpoint defects. As a result, installation and service professionals can arrive at the site already knowing the exact location of the problem. Service calls become much more efficient, saving you the time and labor costs associated with repeat visits. Reduced Maintenance Costs V-Plex can initiate functional smoke detector testing from a VISTA-32FB, VISTA-1 28FBP or VISTA-250FBP series system keypad—automatically logging results locally and sending them to a monitoring center. This drastically reduces system maintenance costs when annual tests or inspections are performed. Honeywell's V-Flex addressable technology offers many new and exciting innovations while fully supporting existing addressable loop products. You'll experience efficiencies in installation and reliability that will add up quickly on your bottom line. Begin experiencing the V-Flex advantage today' ACCESSORIES K DT7500SN V-Plex DUAL TEC Motion Sensor 35 or 50' 01 m or 15m) lenses Pattern containment and pattern shaping through K-Band microwave technology 0, 50, 100 lbs (0, 23, 45 Kg) selectable pet immunity with optional lens 5193SD/5193SDT One Piece Photoelectric Smoke Detector 5193SD1 features (135°F/570C) heat sensor 4959SN Addressable I Overhead Door Contact Rugged aluminum housing and adjustable L bracket type magnet Standard gap: 2" (51 mm) Tamper 4193SN/4293SN Micro-miniature V-Plex Adapter Makes any hardwired device V-Plex ready Built-in serial number for addressing One supervised, one unsupervised zone 1S2500SN V-Plex PIR Motion Sensor 35' or 50' (llm or 15m) lenses 0, 40, 80 lbs (0, 18, 36 Kg) selectable pet immunity with optional lens 2695N V-Plex Holdup Switch Fully supervised Reset key for testing and reset of alarm Stainless steel protective cover 49398N Addressable Surface Mount Contact Traditional "39" style with snap on cover to conceal mounting screws Standard gap: 1.25" (32mm) 5 (1.5m) CL II jacketed cable 41905N Two Zone Remote Point Module DIP switch programmable Left Zone-EOLR supervised, open or closed circuit sensors Right Zone-unsupervised, closed circuit sensors FG1625SN FlexGuard FlexCore signal processor Selectable sensitivity Easy installation with - - FG-701 Tester No minimum range 25 (9.6m) max range 4191 SN-WH Recessed 1/2" (12.7mm) diameter case Standard gap: 7/8" (22mm) Programmable recessed contact with built-in RPM (Remote Point Module) Also available with steel door adapter 41 01 SN Relay Module Form C contacts rated at 2A, 28VACNDC with contact supervision One class B B/style B EOLR supervised aux. - - input zone Operating and power and communication with control via V-Plex loop 4208SNF Universal Class A & Class B Expander Module Provides up to six class B supervised zones and converts two panel zones to class A supervised zones Powered from addressable loop or DC power supply Serial number addressing via DIP switch 4297 Polling Loop Extender Module Isolates and protects different areas of protection - - • Extends loop distance Separate DC input, no loop current drain 4208SN Universal Eight Zone Remote Point Module Remote expansion zone module Supports serial number application VISTAKEY Access Control Now, you can quickly and easily add access control every time you install a VISTA commercial security system. VistaKey maximizes security investments by integrating access control, intrusion detection and fire detection into a single system. You can offer your customers 1-15 doors of seamless integration, and a unique combination of security and access control features: Arms and disarms security system with access card Conveniently connects to the V-Plex bus Tracks employee door entry and locks/unlocks doors on schedule Restricts access based on job function, time or location Events can be recorded to the VISTA event log; printer optional VPLEX-VSI V-Plex Short Isolator Detects and isolates polling loop branches with complete or resistive shorts, and overload or defective polling loop devices on initial power up Can be used to isolate - burglary devices from fire devices, increasing life safety and protection LED indicator reduces troubleshooting time and maintenance costs Powered directly from the V-Plex two-wire polling loop Can be placed on any major or minor branch in any configuration on the polling loop For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 www.honeywell.com LAIPLe(8Rf0 February 2011 0 2011 Honeywell International Inc. Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1645:0127 Page 1 of I CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad©honeywell.com DESIGN: Models 4193SN, *4193 SNP zone expander modules and 4190SN 2-Zone Expansion Module.The modules are accessories for use with Ademco fire alarm control panels supporting polling loop devices. They are intended to be connected to the control unit's polling circuitry and provide point identification for devices which are provided only with a set of dry contacts. Models must be installed within the control panel cabinet or inside a UL listed enclosure. For fire alarm, the supervised zone must be used. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 8-12 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use only with Ademco's separately listed fire alarm control units. NOTE: Formerly 7300-0078:178 *Rev 12-27-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires, June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division