HomeMy WebLinkAbout2511 GATEWAY RD; ; FPC2017-0268; Permit4ity of PERMIT REPORT Carlsbad Print Date: 10/20/2021 Permit No: FPC2017-0268 Job Address: 2511 GATEWAY RD, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2132600200 Track #: Applied: 09/21/2017 Valuation: $8,833,352.40 Lot #: Issued: 10/06/2017 Occupancy Group: Project #: Finaled Close Out: 05/03/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: VIASAT COLD SHELL OFFICE/MANUF BUILDING 13 -FIRE ALARM Applicant: FPContractor: PYRO-COMM SYSTEMS INC PYRO-COMM SYSTEMS INC CHARLES KRETZING 15531 CONTAINER LN 5115 AVENIDA ENCINAS, #G HUNTINGTON BEACH, CA 92649-1530 CARLSBAD, CA 92008-4387 (714) 902-8000 (760) 930-6014 FEE AMOUNT FIRE New Alarm System -__$1,227.00 Total Fees: $1,227.00 Total Payments To Date: $1,227.00 -- -- Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov I FE7C 2 QfJ4g Pyro-Comm Systems, Inc. 5115 Avenida Encinas, Suite G C10 #612153 Carlsbad, CA 92008 (760) 930-6014 Fax (760) 930-6015 ViaSat Cold Shell Bldg 13 Fire Alarm System Submittal I MFG. MODEL # DESCRIPTION CSFM I Notifier NFS-320SYS Control Panel 7165-0028:0243 Notifier UDACT Dialer 7165-0028:0243 Notifier BAT-12260 Batteries N/A I Notifier NFS-LBB Battery Backbox N/A Spaceage SSU00685 Storage Cabinet N/A Notifier FSP-851 Smoke Detector 7272-0028:0206 I Notifier B21OLP Bases 7300-1653:0109 Notifier NBG-12LX Pull Station 7150-0028:0199 Notifier FDM-1 Dual Monitor Module 7300-0028:0219 I Notifier FMM-1 Monitor Module 7300-0028:0219 Sys. Sensor P2W Wall Horn/Strobe 7125-1653:0188 09/19/17 Job #2017409 A DN-60637:F NOT IFIER® Fire Alarm System by Honeywell iIntelligentaFire Alarm Control Panels General I (NFS"320SY1(E) Intelligent Addressable I I The NFS-320SYS intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. As a stand-alone small-to-large system, or as a large network, the ONYX Series of products meet virtually every application requirement. The modular design of the ONYX Series makes system plan- ning easier. The panel can be configured with just a few devices for small building applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional peripheral equipment to suit the application. NOTE: Unless called out with a version-specific "E" at the end of the part number, "NFS-320SYS" refers to models NFS-320SYS and NFS-320SYSE; similarly, "CPU-320SYS" refers to models CPU-320SYS and CPU-320SYSE. Features Certified for seismic applications when used with the appro- priate seismic mounting kit. Approved for Marine applications when used with listed com- patible equipment (see DN-60688). One isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 0r7. Up to 159 detectors (any mix of ion, photo, thermal, or multi- sensor) and 159 modules (NO. manual stations, two-wire smoke, notification, or relay). 318 devices maximum. Standard 80-character display. Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC, ONYXWorks, NFS-3030, NFS-640, and NCA). - Standard network for up to 103 nodes (NFS2-3030, NFS2- 640, NFS-320(C), NFS-320SYS, NCA-2, DVC, ONYX- Works, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP- 300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC is used in network paging. 6.0 A switch mode power supply with four Class NB built-in Notification Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization. Built-in Alarm, Trouble, and Supervisory relays. VeriFire® Tools online/offline program option. Sort Mainte- nance Reports by compensation value (dirty detector), peak alarm value, or address. Autoprogramming and Walk Test reports. Optional universal 318-point DACT. 80-character remote annunciators (up to 32). EIA-485 annunciators, including custom graphics. Printer interface (80-column and 40-column printers). History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. Alarm Verification selection per point, with tally. Positive Alarm Sequence (PAS) Presignal. Silence inhibit and Auto Silence timer options. March time/temporal/California two-stage coding/strobe syn- chronization. Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate. CNFS-32O Full QWERTY keypad. Charger for up to 200 hours of standby power. Non-alarm points for lower priority functions. Remote ACK/Signal Silence/System Reset/Drill via monitor modules. Automatic time control functions, with holiday exceptions. Surface Mount Technology (SMT) electronics. Extensive, built-in transient protection. Powerful Boolean logic equations. FLASHSCAN® INTELLIGENT FEATURES Poll 318 devices in less than two seconds. Activate up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - nine levels. Pre-alarm ONYX intelligent sensing - nine levels. Day/Night automatic sensitivity adjustment. Sensitivity windows: - Ion —0.5 to 2.5%/foot obscuration. - Photo —0.5 to 2.35%/foot obscuration. - Laser (VIEW®) —0.02 to 2.0%/foot obscuration. - Acclimate® PIusTM - 0.5 to 4.0%/foot obscuration. - InteIIiQuadTM - 1.0 to 4.0%/foot obscuration - InteIIiQuad1M PLUS - 1.0 to 4.0%/foot obscuration Drift compensation (U.S. Patent 5,764,142). Degraded mode - in the unlikely event that the CPU- 320SYS microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU-320SYS NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature. Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing. DN-60637:F • 08/09/2012 - Page 1 of 6 Maintenance alert (two levels). Self-optimizing pre-alarm. FSL-751 (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY Revolutionary spot laser design. Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831524). Addressable operation pinpoints the fire location. No moving parts to fail or filters to change. Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATES PLUSTM LOW-PROFILE INTELLIGENT MULTI-SENSOR Detector automatically adjusts sensitivity levels without oper- ator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. FlashScan or CLIP (classic") mode compatible with NFS2- 640, NFS-320. Low-temperature warning signal at 40°F ± 5°F (4.44°C ± 2.77°C). FSC-851 INTELLIQUADTM ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. Six sensitivity levels. FCO-851 INTELLIQUA DTTM PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR Detects all four major elements of a fire. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. Six sensitivity levels. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). Low-pressure CO2 listed. VOICE AND TELEPHONE FEATURES Integrates with FireVoice-25/50 Series. Integrates via serial connection with FireVoice-25/50ZS(T) Series. Telephone applications require ZST versions. HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 A POWER SUPPLY (6.0 A IN ALARM) 120 or 220/240 VAC. Displays battery current/voltage on panel (with display). FlashScan, Exclusive New World-Leading Detector Protocol At the heart of the NFS-320SYS is a set of detection devices and device protocol - FlashScan (U.S. Patent 5539,389). FlashScan is an all-digital protocol that gives superior precision and high noise immunity. I I SLC Intelligent Loop I Up to 32 J s mote DR DEVICES FAPT-851 Acclimate PluSTM — — — — — - Es FSL-751 FlashScan® VIEW® FSC-851 Intelliquad NBG-12LX FMM-1 FAM-1 XP6I10 6 ... FSP-851 FtashScan® photo I/O Modules 110000 10000 etc. IDC Relay Contact FDu-80 FDII-80 FDU-80 EIA -485 ± EtA -485 2048 annunciator/control points KDM-R2 display I MW ACM-8R AcM/AEM-24AT LDM-32 Relay Control LED Annunciator Custom Graphics Optional 318 point UDACT Dual phone 10 Central Station Sample System fN F3 EtA -232 Options "C" cabinet size shown PRN Printer Page 2 of 6— DN-60637:F • 08/09/2012 I 1 I I I I I I In addition to providing quick identification of an active input device, this new protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS-320SYS to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two sec- onds. The microprocessor-based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic informa- tion, such as device address during Walk Test. ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS-320SYS with industry-leading smoke detection capa- bility. These complex algorithms require many calculations on each reading of each detector, and are made possible by the very-high-speed microcomputer used by the NFS-320SYS. Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, such as those caused by electrical interference. Maintenance Warnings: When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value, usually indicative of a hardware problem in the detector; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre- alarm sensitivity can also be selected, based on predetermined levels of alarm. Pre-alarm operation can be latching or self- restoring, and can be used to activate special control functions. Self-Optimizing Pre-Alarm: Each detector may be set for "Self- Optimizing" pre-alarm. In this special mode, the detector learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to con- sider readings from nearby sensors in making alarm or pre- alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. Field Programming Options Autoprogram is a timesaving feature of the NFS-320SYS. It is a special software routine that allows the NFS-320SYS to learn" what devices are physically connected and automatically load them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installa- tion, even if only a portion of the detectors are installed. Keypad Program Edit (with KDM-R2) The NFS-320SYS, like all NOTIFIER intelligent panels, has the exclusive feature of pro- gram creation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS-320SYS software is such that each point entry car- ries its own program, including control-by-event links to other points. This allows the program to be entered with independent per-point segments, while the NFS-320SYS simultaneously monitors other (already installed) points for alarm conditions. VeriFire® Tools is an off line programming and test utility that can greatly reduce installation programming time, and increase con- fidence in the site-specific software. It is Windows®-based and provides technologically advanced capabilities to aid the installer. The installer may create the entire program for the NFS-320SYS in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Placement of Equipment in Chassis and Cabinet The following guidelines outline the NFS-320SYS's flexible sys- tem design. Rows: The first row of equipment in the cabinet mounts in the chassis shipped with the CPU. Mount the second, third, or fourth rows of equipment in a CHS-4 Series chassis. Other options are available; see your panel's installation manual. Wiring: When designing the cabinet layout, consider separation of power-limited and non-power-limited wiring as discussed in the NFS-320SYS Installation Manual. Positions: A chassis offers four basic side-by-side positions for components; the number of modules that can be mounted in each position depends on the chassis model and the size of the individual module. There are a variety of standoffs and hardware items available for different combinations and configurations of components. KDM-R2 Controls and Indicators Program Keypad: QWERTY type (keyboard layout, below). 12 LED indicators: Power; Fire Alarm; Pre-Alarm; Security; Supervisory; System Trouble; Signals Silenced; Points Dis- abled; Control Active; Abort; Pre-Discharge; Discharge. Membrane Switch Controls: Acknowledge/Scroll Display; Sig- nal Silence; Drill; System Reset; Lamp Test. LCD Display: 80 characters (2 x 40) with long-life LED back- light. Ordering Information "Configuration Guidelines" on page 4 "Networking Options" on page 4 "Auxiliary Power Supplies and Batteries" on page 4 "Audio Options" on page 4 "Compatible Devices, ElA-232 Ports" on page 4 "Compatible Devices, ElA-485 Ports" on page 4 "Compatible Intelligent Devices" on page 4 "Enclosures, Chassis, and Dress Plates" on page 5 "Other Options" on page 5 I n I 1 I I I I I I DN-60637:F • 08/09/2012 - Page 3 of 6 CONFIGURATION GUIDELINES NOTE: Stand-alone and network systems require a main display. On stand-alone systems, the panel's keypad provides the required display. On network systems (two or more networked fire panel nodes), at least one NCA-2, NCS, or ONYX Works annunciation device is required. NCA-2: Network Control Annunciator, 640 characters. On net- work systems, the NCA-2 connects to (and requires) an NCM or HS-NCM network communications module. Mounts in a row of FACP node or in two annunciator positions. CPU-320SYS: Central processing unit with integral 3.0 A (6.0 A in alarm) power supply for an NFS-320SYS system. includes CPU factory-mounted on a chassis one Signaling Line Circuit; installation, programming and operating manuals. Order one per system or as necessary on a network system. CPU-320SYSE: Same as CPU-320SYS but requires 220 VAC, 1.5 A, (3.0 A in alarm). DP-DISP2: Dress panel for top row in cabinet with CPU- 320SYS/E installed. BMP-1: Blank module for unused module positions. BP24: Battery plate, required. NETWORKING OPTIONS NCM-W, NCM-F: Standard Network Communications Modules. Wire and multi-mode fiber versions available. See DN-6861. HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed network communications modules that can connect to two nodes. Wire, single-mode fiber, multi-mode fiber, and media conversion mod- els are available. See DN-60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN-6971. ONYXWorks: UL-listed graphics PC workstation, software, and computer hardware. See DN-7048 for specific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. See DN-60499. AUXILIARY POWER SUPPLIES AND BATTERIES ACPS-610: 6.0 or 10 A addressable charging power supply. See DN-60244. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and trans- fer relay, and overcurrent protection. Mounts on two of four posi- tions on a CHS-4L or CHS-4 chassis. See DN-5952. FCPS-24S6/-24S8: Remote 6 A and 8 A power supplies with battery charger. See DN-6927. BAT Series: Batteries. NFS-320SYS uses two 12 volt, 18 to 200 AH batteries. See DN-6933. AUDIO OPTIONS NFV-25/50: 25 watt, 25 yAMS, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, and single-/dualchannel Class A or Class B speaker circuits. See ON-7004. NFV-25/50DA: Single channel, 25 Watt, 25 VRMS, Distributed Audio Panel. Interfaces with the NFV-25/50. See DN-60048. NFV-25/50DAZS: Single channel, 25 Watt, 25 Vrms, Distributed Audio Panel. Interfaces with the NFV-25/50ZS(T). Can be auto- matically activated via the Zone System serial communication link from the NFV-25/50ZS(T). See DN-60049. NFV-25/50ZS: 25 watt, 25 Vrms, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- ital message generator, zone splitter module (ACC-ZSM), zone page module with keypad (ACC-ZPMK). See DN-7003 NFV-25/50ZST: 25 watt, 25 Vrms, emergency Voice Evacuation Control Panel (VECP) with integral commercial microphone, dig- Page 4 of 6- DN-60637:F • 08/09/2012 ital message generator, zone splitter module (ACC-ZSM), zone page module with keypad (ACC-ZPMK). See DN-60337. COMPATIBLE DEVICES, EIA -232 PORTS PRN-6: 80-column printer. See DN-6956. VS4095/S2: Printer, 40-column, 24 V. Mounted in external back- box. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACP5 and/or peripherals. See DN-6870. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by pow- ered-up switch selection) by point to be red, green, or yellow; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT, expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM48A: ONYX Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A, expands the ACM-48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. LCD-80/FDU-80: 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See LCD- 80/-80TM (DN-3 198) and FDU-80 (DN-6820). LCD2-80: Terminal mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See DN-60548. LDM: Lamp Driver Modules LDM-32, LDM-E32, and LDM-R32; remote custom graphic driver modules. See DN-0551. SCS: Smoke control stations SCS-8, SCE-8, with lamp drivers SCS-8L, SCE-8L; eight (expandable to 16) circuits (HVAC only). See DN-4818. TM4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit. Mounts in panel module position (single-address-style) or in CHS2-M2 position. See ON- 6860. UDACT: Universal Digital Alarm Communicator Transmitter. See DN-4867. UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides posi- tive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from lBMt-compatible PCs (requires optional programming kit). Up to 256 programmable codes. See DN-3404. COMPATIBLE INTELLIGENT DEVICES BEAMHK: Heating kit for transmitter/receiver unit of FSB- 200(S) below. See DN-6985. BEAMHRK: Heating kit for use with the reflector of FSB-200(S) below. See DN-6985. BEAMLRK: Long-range accessory kit, FSB-200(S) below. BEAMMRK: Multi-mount kit, FSB-200(S) below. BEAMSMK: Surface-mount kit, FSB-200(S) below. FSB-200: Intelligent beam smoke detector. See DN-6985. FSB-200S: Intelligent beam smoke detector with integral sensi- tivity test. See DN-6895. I I I I 1 I I I I I I I FSC-851: FlashScan IntelliQuad Advanced Multi-Criteria Detec- tor. See DN-604 12. FCO-851: FlashScanintelliQuad PLUS Advanced Multi-Criteria Fire/CO Detector. See DN-60689. FSI-851: Low-profile FlashScan ionization detector. See DN- 6934. FSP-851: Low-profile FlashScan photoelectric detector. See DN-6935. FSP-851T: Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6935. FSP-851 R: Remote-test capable photoelectric detector for use with DNR(W) duct detector housings. See DN-6935. FST-851: FlashScan thermal detector 135°F (57C). See ON- 6936. FST-851 R: FlashScan thermal detector 135°F (57°C) with rate- of-rise. See DN-6936. FST-851H: FlashScan 190°F (88°C) high-temperature thermal detector. See DN-6936. FAPT-851: FlashScan Acclimate Plus low-profile multi-sensor detector. See DN-6937. FSL-751: FlashScan VIEW laser photo detector. See DN-6886. DNR: InnovairFIex low-flow non-relay duct-detector housing (order FSP-851/FSP-851R separately). Replaces FSD-751PL/ FSD-751 RPL. See DN-60429. DNRW: Same as above with NEMA4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. B224B1: Isolator base for low-profile detectors. See DN-60054. B21OLP: Low-profile base. Standard U.S. style. Replaces B71OLP. See DN-60054. B501: European-style, 4° (10.16 cm) base. See DN-60054. B200S: Intelligent programmable sounder base, capable of pro- ducing a variety of tone patterns including ANSI Temporal 3. Compatible with sychronization protocol. See DN-60054. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN-60054. FMM-1: FlashScan monitor module. See DN-6720. FDM-1: FlashScan dual monitor module. See DN-6 720. FZM-1: FlashScan two-wire detector monitor module. See DN- 6720. - FMM-101: FlashScan miniature monitor module. See DN-6 720. FCM-1: FlashScan NAC control module. See DN-6 724. FCM-1-REL: FlashScan releasing control module. See DN- 60390. FRM-1: FlashScan relay module. See DN-6 724. FDRM-1: FlashScan dual monitor/dual relay module. See DN- 60709. NBG-12LX: Manual fire alarm station, addressable. See ON- 6726. ISO-X: Isolator module. See DN-2243. XP6-C: FlashScan six-circuit supervised control module. See DN-6924. XP6-MA: FlashScan six-zone interface module; connects intelli- gent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R: FlashScan six-relay (Form-C) control module. See ON- 6926. XP10-M: FlashScan ten-input monitor module. See DN-6923. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB4 Series Enclosure: The NFS-320SYS mounts in a CAB- 4 Series enclosure (available in three sizes, B-D). The backbox and door are ordered separately. It requires BP2-4 battery plate. A trim ring is available for semi-flush mounting. EQ Series Cabinets: EQ series cabinets will house amplifiers, power supplies, battery chargers and control modules. EQ cabi- nets are available in three sizes, "B" through "D". See ON- 60229. CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. For a full list of required and optional equipment, see DN-60688. CHS4: Chassis for mounting optional equipment. CHS4L: Low-profile four-position Chassis. DP-1B: Blank Dress panel. Provides dead-front panel for unused tiers. NFS-LBB: Battery Box (required for batteries larger than 26 AH). NFS-LBBR: Same as above but red. BB-UZC: Backbox for housing the UZC-256 in applications where the UZC-256 will not fit in panel enclosure. Black; for red, order BB-UZC-R. SEISKIT-CAB: Seismic mounting kit. Required for seismic-certi- fied applications with NFS-3205Y5 and other equipment mounted in CAB-4 Series Enclosures. Includes battery bracket for two batteries up to 26 AH. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. SEISKIT-PS/214: Seismic mounting kit for the FCPS-2456/58 and CAB-PSi. Includes battery bracket for two 7 AH or 12 AH batteries. OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 4I1UDAC: Digital alarm communicator. See DN-6746. IPDACT-2/2UD, IPDACT Internet Monitoring Module: Con- nects to primary and secondary DACT telephone output ports for internet communications over customer-provided ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mount- ing an IPDACT-2/2UD onto the panel chassis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT: Y-adaptor option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket. Red; for black, order IPENC-B. IPGSM-DP: Internet and Digital Cellular Fire Alarm Communi- cator. Provides selectable configurable paths: cellular only, IP only, or IP primary with cellular backup. Connects to the primary and secondary ports of a DACT. Replaces IPGSM-COM. See DH-60695. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panel's installation manual, the SLC manual, and the Device Compatibility Document. DN-60637:F • 08/09/2012 - Page 5 of 6 I I I U I I I I I SYSTEM SPECIFICATIONS System Capacity Intelligent Signaling Line Circuits .........................................1 Intelligent detectors .........................................................159 Addressable monitor/control modules ..............................159 Programmable software zones...........................................99 Special programming zones...............................................14 LCD annunciators per CPU-320SYS/E (observe power)..................................................................32 ACS annunciators per CPU-320SYS/E ........................ 32 addresses x 64 points Specifications Primary input power, CPU-320SYS board: 120 VAC, 50/60 Hz, 5.0 A. CPU-320SYS/E board: 220/240 VAC, 50/60 Hz, 2.5 A. Total output 24 V power: 6.0 A in alarm. NOTE: The power supply has a total of 6.0 Amps of available power. This is shared by all internal circuits. Standard notification circuits (4): 1.5 A each. Four-wire detector power: 1.25 A. Non-resettable regulated power outputs: 1.25 A each. Battery charger range: 18 AH - 200 AH. Use separate cabi- net for batteries over 26 AH. Float rate: 27.6 V. Shipping Weight CPU-320SYS:16.95 lb (7.69 kg). CPU-320SYSE: 17.2 lb (7.80 kg). Cabinet Specifications NFS-320SYS sytems can be installed in CAB-4 Series cabinets (three sizes with various door options, see DN-6857). Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0— 49°C and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C. However, the useful life of the systems standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. There- fore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15-27°C. Agency Listings and Approvals The listings and approvals below apply to the basic control panel. In some cases, certain modules may not be listed by cer- tain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL Listed: S635. ULC Listed: S635. FM Approved. CSFM: 7165-0028:0243. FDNY: COA#6085. When used with the CAB-BM Marine System, appropriate seismic bracket, and marine approved devices, these ONYX fire alarm control panels are approved by the following agen- cies: US Coast Guard: 161.002/50/0 (Standard 46 CFR). Lloyd's Register: 11/600013 (ENV 3 category). American Bureau of Shipping. NOTE: For information on the CAB-BM marine system, see DN-60688. Standards The NFS-320SYS complies with the following UL Standards and NFPA 72, IBC, and CBC Fire Alarm Systems requirements: UL 864, 9th Edition (Fire). UL 1076 (Burglary). LOCAL (Automatic, Manual, Waterflow and Sprinkler Super- visory). AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). REMOTE STATION (Automatic, Manual and Waterflow) (requires 4XTMF). PROPRIETARY (Automatic, Manual and Waterflow). Not applicable for FM. EMERGENCY VOICE/ALARM. OT, PSDN (other technologies, packet switches, data net- work.) IBC 2000, IBC 2003, IBC 2006, IBC2009 (Seismic). CBC 2007 (Seismic). I F] I I 1 NoTI.FIRE.NErM, lntelliOuad°M, and ONYXWorksTM are trademarks; and Acclimate® PlusTM, FlashScan®, NOTIFIER®, ONYX®, VeriFire®, and VIEW® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. IBM® is a registered trademark of IBM Corporation. @2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I iso ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 933=1=1 We cannot cover all specific applications or anticipate all requirements. 111111111110111111 UNFAMMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the u.S.A. I For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. - www.notifier.com Page 6 of 6— DN-60637:F • 08/09/2012 1 dn-4867:b • D-160 (UDATCT) NOTIFIER® Universal Digital Alarm Communicator Transmitter by Honeywell Annunciator Control Systems General r r The Universal Digital Alarm Communicator Transmitter (UDACT) is designed for use on the Notifier NFS-320, NFS2- 640, NFS2-3030, NFS-640 and NFS-3030 Fire Alarm Control Panels and on the NCA-2 and NCA Network Control Annunci- ator. When used in conjunction with the NCA-2 network con- trol annunciators the UDACT can report the status of all control panels on NOTl.FIRE.NETTM. The UDACT transmits system status to UL listed Central Station Receivers via the public switched telephone network. NOTE: The UDACT can also be used with legacy panels. Please refer to the UDACT manual for more information. The UDACT is compact in size and may be mounted externally in a separate cabinet. EIA-485 annunciator communications bus and regulated 24-volt connections are required. The UDACT is capable of transmitting the status of software zones (Alarm and Trouble), System Trouble, Panel Off-Normal, Supervisory, Bell Trouble, Low Battery, and AC Fail. The UDACT is capable of transmitting all of the zone and point sta- tus associated with each panel. When the UDACT is used with the , NFS-3030, NFS2-3030, and NCA-2 it is capable of reporting up to 2,040 points. Reporting may be in the form of points or zones (refer to the UDACT manual for specific reporting parameters). The first 568 points transmitted may be programmed for a variety of types, including fire, waterfiow, supervisory, etc. Remaining points transmitted are for fire alarm only. NOTE: Descriptions regarding point capacity, listed above, are for receivers which receive in Ademco Contact ID format. See chart on page 2 for compatible receivers. Features Maximum of 14 point trouble messages transmitted per hour. Dual phone lines. Dual telephone line voltage detect. Surface Mount Technology. Compact in size: 6.75' x 4.25" (17.145 x 10.795 cm). Built-in programmer. Built-in 4-character red 7-segment LED display. Manual Test Report function. Manual Transmission Clear function. Mounts in a separate enclosure (ABS-8RB or UBS-1). Communicates vital system status including: - Independent zone fire alarm. - Independent zone non-fire alarm. - Independent zone trouble. - Independent zone supervisory. - AC (mains) Power Loss (programmable). - Low Battery and Earth Fault. - System Off-Normal. - 12 or 24 hour test signal. - Abnormal Test Signal per new UL requirements. - EIA-485 Communication Bus Failure. Annunciation of UDACT Troubles including: loss of phone lines, communication failure with either Central Station, total communications failure. Troubleshoot Mode converts keypad to DTMF touchpad. Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kissoff, Comm Fail, Primary Line Seize, Secondary Line Seize and Modem Communications. Open Collector relay driver for Total Communications Fail- ure or UDACT trouble. Real-time clock. Extensive transient protection. Simple EIA-485 interface to host panel. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL Listed: S635 ULC Listed: CS100 Vol. VII MEA: 328-94-E; 317-01-E3 CSFM: 7300-0028:174; 7165-0028:214; 7165-0028:224; 7170-0228:216; 7170-0028:223; 7165-0028:243, 7170- 0028:244 INDUSTRY CANADA: 2132 6030 A FCC: 1W6-USA-20723-AL-E FM Approved Communication Formats 3+1 Standard • 4+1 Standard • 4+2 Standard 4+1 and 4+2 Ademco Express • Ademco Contact ID dn-4867:b • 03/27/09 - Page 1 of 4 I I [1 I I I I ABS-8RB for remote mounting [9.94'(25.2476cm)H x 4.63(1 1.7602cm)W x 2.5"(6.35cm)D] NOTE: Ademco Contact ID must be used for independent zone reporting. Type Mode Feature Ademco Contact ID format only) Use Type Mode to identify reports to Central Station as: Fire Alarm Burglary Supervisory 24 hour Non-Burglary Pull Station High Temperature Heat Detector Low Temperature Waterflow Low Water Pressure Duct Detector Low Water Level Flame Sensor Pump Failure Smoke Zone Electrical Specifications Standby current: 40 mA. Current while communicating: 75 mA. Maximum current while communicating and with open collec- tor output activated: 100 mA. Voltage: Regulated 24 volts. Range: 21.2 to 28.2 volts. Ordering Information (UDA•1CT: Universal Digital Alarm Communicator Transmitter. Includes operating and programming instructions, and mount- ing hardware. MCBL-7: DACT phone cord, 7 ft (2.13 m) long (two required). ABS-8RB: Metal enclosure for externally mounting UDACT up to 6,000 ft./1828.8 m from host FACP. 9.94° H x 4.63° W x 2.50° D (cm: 25.248 H x 11.760 W x 6.350 D). UBS-1: Metal enclosure. Includes viewing window and optional relay mounting capability. R-10E: SPDT Form-C relay. Contacts rated for 10 A @ 115 VAC. Connects to open collector relay driver. R-20E: DPDT Two Form-C relays. Contacts rated for 10A @ 115 VAC. Connects to open collector relay driver. FBD-1: Ferrite bead kit. Use for remote mounting only. ROM1-UDACT: EPROM upgrade kit. I I Ii Iii I I I UDACT shown in UBS-1 Page 2 of 4— dn-4867:b • 03/27/09 I Format # (Addresses 16 & 42) Ademco 685 (1) Silent t csoo FBI CP220FB Osborne Hoffman Models 1&2 Radionics 6000/6500 (5) Sescoa 3000R (7) SurGuard MLR-2 (9) 0 4 + 1 Ademco Express X X X 1 4 + 2 Ademco Express X X(8) X 2 3 + 1 IStandardI1800I2300 X (2) X X(4) X X(5,6) X X 3 (NOT USED) EX 4 3 + 1 /Standard/1900/1400 X (2) X(4) X X X 5 (NOT USED) 6 4 + 1 /Standard/1800/2300 X (2) X X(4) X X(5) X X 7 (NOT USED) 8 4 + 1 /Standard/1900/1400 X X (2) X(4) X X X 9 (NOT USED) A 4 + 2 /Standard/1900/2300 X X (2) X X(4) X X(5) X X B (NOT USED) C 4 + 2 /Standard/190011400 X X (2) X(4) X X X D (NOT USED) E Ademco Contact ID X X X X F (NOT USED) With 685-8 Line Card with Rev. 4.4d software. With 9002 Line Card Rev. 9035 software or 9032 Line Card with 9326A software. Rev. 4.0 software. FBI CP220FB Rec-1 1 Line Card with Rev. 2.6 software and a memory card with Rev. 3.8 software. Model 6500 with Rev. 600 software. Model 6000 with Rev. 204 software. With Rev. B control card at Rev. 1.4 software and Rev. C line card at Rev. 1.5 software. Model 2 only. Version 1.62 software. dn-4867:b • 03/27/09 - Page 3 of 4 I NOTI.FlRE.NETTM is a trademark and Notifier@ is a registered trademark of Honeywell International Inc. ©2006 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I O 9001 We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. OINNIN g MAMR1131RIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 4 of 4— dn-4867:b • 03/27/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 1_50028T02J\ Page 1 of 4 CATEGORY: 7165- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyevhoneyweU.com DESIGN: Models NFS2-640, NFS-320/C (R), andi SISiSJfire alarm control units. Local, auxiliary, remote station (PPU), proprietary (PPU), central station (PPU), manual, automatic, waterfowl and sprinkler supervisory services. Also suitable for releasing service, Process Management and Emergency Voice/Alarm communication System * Model numbers may be followed by an 'R" suffix representing the enclosure color being red. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: ACM-8R, -16AT, -32A, -24AT, 48A; Annunciator Control Modules ACPS-610, AMPS-24; Addressable power supply/charger ADP413, -A4, -1, -2, DP-D1SP2; Dress Panel AEM-16AT, -32A, -24AT, -48A; Annunciator Expander Modules AFM-16A, -16AT, -32A; Annunciator Fixed Modules AKS-1 B; Annunciator Key Switch APS2-6R; Power supply BB-100, -200, NFS-LBB/-LBBR; Battery Boxes BGRA-SCS, BGRB-SCS; Smoke Control Station BMP-1; Blank Module BP4, BP24; Battery Dress Plates CAB-314 Series; Enclosure CAB-RP, CAB-RPR; Cabinets CEF-SCS; Smoke Control Station CHS4, CHS-4N, CHS4L; Chassis CPU2-640, CPU-320SYS; CPU Board CRT-2; Display Terminal DP-1B; Blank Panel DPA-1A411/2, DP-DISP2; Dress Panel DPI-232; Panel Interface DR-A4, DR-A4B, DR-A4BR, DR-A4R; Door Assembly DR-AA4, DR-AA413, DR-AA4BR, DR-AA4R; Door Assembly DR-133F; Door Assembly DR-134, DR-13413, DR-B4BR, DR-134R; Door Assembly DR-C4, DR-C413, DR-C4BR, DR-C4R; Door Assembly DR-D4, DR-D4B, DR-D4BR, DR-D4R; Door Assembly Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ov operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator I Fire Engineering Division I Listing No. 7165-0028:0243 I EQ Series; Cabinets Page 2of4 EQBB-B4, EQBB-C4, EQBB-D4; Backbox Assembly I EQDR-B4, EQDR-C4, EQDR-D4; Door Assembly FCM-1, FCM-1-REL; Releasing Control Module FCPS-24S6, -24S8; Field Charger/Power Supply FDM-1; Dual Monitor Module I FDRM-1:Multiple Module with two Relay Outputs FDU-80/-80G; Remote Annunciator FIRSTVISION-LCDIENC; Interactive Firefighters display/enclosure l FRM-1; Relay Module FTM-1; Control Module FZM-1 FMM-1, FMM-1 01; Monitor Modules HS-NCM-W/-MF/-SF/-WMF/-WSF/-MSSF; High Speed Network Control Modules I IPDACT-2/-2UD; IP Fire Alarm Communicator ISO-X; Isolator Module KAPS-24, CPS-24; Power Supply I KDM-R2; Keyboard Display Module LCD-80, -160; Annunciators LCD-80TM; Annunciator Terminal Module LCD LCD2-80; Remote Annunciator I LDM-32/-E32/-R32; Lamp Driver Module LEM-320/ELEM-320; Loop Expander Module NBG-12LRA; Agent Releasing Abort Station I NBG-12LX; Addressable Manual Pull Station NCA, NCA-2; Network Communication Annunciator NCM-W, -F; Network Control Module NCS4-W-ONYX, NCS4-F-ONYX; Network Control Station I NCS5-W-ONYX, NCSS-F-ONYX; Network Control Station NFS-LBB/NFS-LBBR; Battery Box/Red NFS-320SYS; Chassis I NFV-25150, NFV-25150Z5/ZST; Voice Evacuation Control Panels NFV-25/50DA, NFV-25/50DAZS; Distributed Audio Panels ONYXWorks-EW/-NW-/NF/-HNW/-HNMF/-HNSF/-TS/-EW-TS/-NF-TS/-HW-TS/ -HNMFT/-HNSFT/-HNWT; PC workstation for NOTI.FIRE.NET, Wire/Fiber/ I with Touch screen monitors PRN-6; Printer RKS-S; Remote Security Key Switch I RPT-W, -485W; Repeater Wire RPT-F; Repeater Fiber RPT -485FW; Repeater Fiber/Wre RSA-SCS, RSB-SCS, RSC-SCS, RSD-SCS, RSE-SCS; Smoke Control Station I SBB-A3F; Backbox Assembly SBB-A4, SBB-A4R, SBB-AA4, SBB-M4R; Backbox Assembly SBB-134, SBB-B4R-L8, SBB-C4, SBB-C4R; Backbox Assembly I SBB-D4, SBB-D4R; Backbox Assembly Rev. 10-29-13 gt I .. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTIL.LO, Program Coordinator I Fire Engineering Division Listing No. 7165-0028:0243 Page 3 of 4 SCE-8; Smoke Control Expander SCS-8L; Smoke Control Lamp Driver Station SCE-8L; Smoke Control Expander Lamp SCS-8; Smoke Control Station STS-1; Security Tamper Switch TM-4; Transmitter Module TR-A41-B3NI-B4/-C4/-D3N/-D4; Trim Ring UDACT-2; Universal DACT UZC-256; Universal Zone Coder VP-213; Dress Panel XP5-Cl-M; Transponder Modules XP6-C; Supervised Control Modules XP6-MA; Six Zone Interface Modules XP6-R; Six Relay Control Modules XP10-M(A); Ten Input Monitor Modules XPM-8L; Transponder Monitor Modules The following models are intended for use on NFS2-640 only: AA-30, -100, -120; Amplifiers ACT-1, -2, -4, -25, -70; Audio Coupling Transformer ADDR-B4/-B4R/-C4/-C4R/-D4/-D4R; Door Assemblies AMG-E; Audio Message Generator AVL-1; Audio Voice Link BDA-25V/-70V; Backup Digital Audio Amplifiers CHS2-M2, CA-1, CA-2; Chassis CMIC-1, CMIC-RP; Microphone Assembly DAA-5025/-5070; Digital Audio Amplifiers DAA-5025F/DAA-5025SF; Digital Audio Amplifiers DAA-507OFIDAA-5070SF; Digital Audio Amplifiers, Fiber Mode DAA-75 Series; Digital Audio Amplifiers DAA-7525, DAA-7525F, DAA-7525SF; Digital Audio Amplifiers DAA2-5025/-5070/-7525; Digital Audio Amplifiers DAX-3525/-3570/-50251-5070; Digital Audio Amplifiers DS-AMP/E; Digital Series Audio Amplifier DS-BDA; Digital Series Backup Amplifier DS-DB; Digital Series Distribution Board DS-FM, DS-RFM, DS-SFM; Digital Series Fiber Module DVC; Digital Voice Command DVC-EMI-EMF/-EMSF; Digital Voice Command Extended Memory Module DVC-RPU; Remote Paging Unit FFT-7, -7S; Fire Fighter's Telephone FHS; Fireman's Handset FPJ; Fireman's Phone Jack RM-1, RM-1 SA; Remote Microphone Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator I Fire Engineering Division Listing No. 7165-0028:0243 Page 4 of 4 TELH-1; Telephone Assembly XPIQ; Transponder Quad Intelligent Audio INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Label APPROVAL: Listed as fire alarm control units suitable for use in high-rise applications when used in conjunction with separately listed compatible initiating and indicating devices. *Control units may be used with Notifier's First Command NFC-50/100 emergency voice evacuation panals (CSFM # 6911-0028:0265). This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: 1. For Fire Alarm Verification feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 Seconds. 2. Combined with 7170-028:244 *Rev. 10-29-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I DN-6933:C1 • E-205 i(BA7fSeries Batteries E Sealed Lead-Acid by Honeywell General BAT Series Batteries are Power Sonic brand batteries. BAT Series (or Power Sonic brand) batteries are recommended for secondary power or backup power for all NOTIFIER fire alarm control equipment. Features Provide secondary power for control panels. Sealed and maintenance-free. Overcharge protected. Easy handling with leakproof construction. Ruggedly constructed, high-impact case (ABS, polystyrene, or polypropylene, depending on models). Long service life. Compact design. Agency Listings and Approvals The listings and approvals below apply to BAT Series Batteries. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Recognized Components: MH20845 (Power-Sonic) 6933c0v.jpg Ordering Information BAT-1250-BP: 10-unit bulk pack of BAT-1250 (12 V 5 AH) BAT-1270-BP: 5-unit bulk pack of BAT-1270 (12 V 7 AH) BAT-12120-BP: 4-unit bulk pack of BAT-12120 (12V 12 AH) BAT-12180-BP: 2-unit bulk pack of BAT-12180 (12 V 18 AH) BP: 2-unit bulk pack of BAT-12260 (12 V 26 AH) BAT-12550: single battery (12 V 55 AH) BAT-121000: single battery (12 V 100 AH) Part Number Reference & Specifications Battery Description DIMENSIONS Part Power ______ _______ Nominal Nominal Capacity Width Depth Height Height over terminal Weight Number Sonic Part Number Voltage f2Ohr. in. mm in. mm in. mm in. mm lb. kg. rate A. H. BAT-1250 PS-1250 12 5 sealed 3.54 90 2.76 70 -4.02 102 4.21 107 zr- i--- BAT-i 270 PS-1270 12 7 sealed 595 151 256 65 3.7 94 3.86 98 4.8 2.18 BAT-12120 PS-12120 12 12 sealed 5.95 151 386 98 3.7 94 3.94 100 792 3.59 BAT-12180 PS-12180 12 18 sealed 7.13 181 2.99 76 6.57 167 6.57 167 12.6 5.8 LBAT-12260; PS-12260 12 26 sealed 6.56 167 6.97 177 4.92 125 4.92 125 17 7.71 BAT-12550 PS-12250 12 55 sealed 19.04 230 654 138 11 8.2 208 8.98 228 36 16.33 BAT-121000 PS-121000 12 100 sealed 12 305 6.6 68 8.2 1208 8.98 1228 68 30.84 DN-6933:C1 • 7/13/2011 - Page 1 of 2 6.51-13 6.01-12 ' 5.01-10 M 05 4.51 g 8 L Characteristic Discharge Curves t 2 3 5 10 2030 60 2 3 5 10 2030 minutes ..- hours Discharge Time © 20°C (68°F) 120% Effect of Temperature on Capacity 100% . 80% (0 of . 60% U (a om 40% 20% 0% -20'-10* 0° 10° 20° 30° 40° 50° 60° Temperature (Degrees C.) MENEM@ usm a PAP NA 2. a PEP 0 100% 90% 0 80% 70% (If 60% >S C) a 50% Co C) 40% 0% Charging is NOT necessary unless 100% of capacity is required. Charging before - (4 iF) use is necessary to help recover - full capacity. - s— L Charge may failtorestore full capacity. - - 40°C 30°C - 20°C - (104°F) (86°F) (68°F) DO NOT let batteries reach this state. 0 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) at left: PS-121000 Shelf-Life and Storage O N-- MINE NUNN 16111ME111101 EMINER 1 91 uoiuIi!!i1 Rema iIul -III 1.2 2.4 14.0 V 13.0 V 12.0 V Co 11.0 V is C 10.0v 9.oV 8.0 V Iv! i600 6 12 24 36481 2 4 6 810 20 40 MINUTES x HOURS Discharge Time - at left: PS-121000 Discharge Characteristics Batteries display trademarks of the manufacturer. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I 0 9001 We try to keep our product information up-to-date and accurate. - dl We cannot cover all specific applications or anticipate all requirements. iLlHlNL & MNIMt1uRIN9 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6933:C1 • 7/13/2011 DN-6040:A2 • E-191 0 NOTIFIER® by Honeywell Power Supplies General CHG-1 20 Battery Charger The CHG-1 20 is a state-of-the-art battery charging system designed for use with NOTIFIER Fire Alarm Control Panels (FACPs). It is designed to charge lead-acid batteries between 25 and 120 ampere-hours (AH). Features Charges sealed lead-acid batteries. Automatic float-type battery charger. Rated for batteries of 25 to 120 ampere-hours. Obtains full float voltage within 48 hours. For use on any 24-volt FACP which can handle the speci- fied batteries and can disable the local charger. AC Fail delay (central station applications) per latest NFPA requirements. Form-C Trouble contact. Dual outputs, for easy load distribution. Diagnostic LEDs: - Primary AC On - Charger Trouble. - Ground Fault. - Hi Charge. - Lo Charge. - Battery Voltage Level (3 LEDs). - Low Battery. Black or red NFS-LBB(R) battery cabinet (optional). Field-selectable input voltage, 120 VAC or 230 VAC. Charges: - 26 AH batteries within 9 hours. - 55/60 AH batteries within 20 hours. - 120 AH batteries within 38 hours. NOTE: Values per NOTIFIER testing. Construction and Operation The CHG-1 20 consists of a PC board and mounting chassis. Charging current is provided automatically when the battery voltage falls below the charger's output voltage. Applications Use the CHG-120 when batteries required for standby are rated between 25 to 120 AH. CHG.1 20 Specifications Primary AC (T131): —115 VAC, 60 Hz, 2A. - 230 VAC, 50 Hz, 1 A. Form-C relay (TB3): 5 A at 30 VDC. Float charge voltage: 27.6 VDC. Maximum charging current: 4.5 A. Fuses F1-F3: 15 A. Battery sizes: 26 AH to 120 AH. Charging time (to charge two fully discharged batteries): - 25 AH = 9 hours. - 55 AH/60 AH = 20 hours. —120 AH = 38 hours. Installation The CHG-120 has a variety of mounting options. It can be mounted in either a CAB-4 Series backbox or remotely in the NFS-LBB Battery Backbox. Install the CHG-120 within 20 feet (6.096 m) of the main FACR When mounting in a CAB-4 Series backbox: The CHG-1 20 can be mounted in the main power supply position, on the lower left of the CAB-4 Series backbox. Using self-tapping screws, the CHG-120 can be mounted in the lower right position (normally, where the batteries are mounted) of the CAB-4 Series backbox. When mounting remotely in the NFS-LBB: The CHG-120 mounts in the left position of the backbox. NOTE: Only one 55 AH battery or two 26 AH batteries will mount with the charger board in the NFS-LBB. NFS-LBB Battery _Box Battery Configuration& The battery backbox can mount configurations of batteries as follows: Without CHG-120 mounted internally: - Up to two 26 AH batteries. - Up to two 55/60 AH batteries. -One 100 AH battery. With CHG-1 20 mounted internally: - Up to two 26 AH batteries. - One 55/60 AH battery. -One 100 AH battery. ON-6040:A2 • 10/18/2012 - Page 1 of 2 CHG-1 20 Features I I I I I I Voltage Selection Switch for 115 VAC or 230 VAC operation \ iSA replaceable fuses - provide short circuit and overload protection Form-C Relay to other devices - Two output circuits to toad (power supply, sax, power supply, amplifier, etc.( _25 AH-120 AH Battery Connections Optional Ammeter Connection Open collector Trouble Daisy Chain Connections - External Trouble input -LBBBattery Backbox I NOTE: When 100 AH batteries are required, a NFS-LBB is required to mount each 100 AH battery. The CHG-120 can mount in either the CAB-4 Series backbox or in a third NFS-LBB in this configuration. Product Line Information CHG-120: Battery charger circuit board and mounting chassis. Includes mounting hardware and installation instructions. BAT-1 2260: 26 AH, 12-volt, sealed lead-acid battery. Order as bulk pack BAT-12260-13P, contains two. See data sheet DN- 6933. BAT-12550: 55 AH, 12-volt, sealed lead-acid battery. See data sheet DN-6933. BAT-121000: 100 AH, 12-volt, sealed lead-acid battery. See data sheet DN-6933. (FS.LBT: Battery Backbox - holds up to two BAT-1 2550 55 AH batteries or one BAT-121000 100 AH battery. Dimensions: Box: 24.0 (61.0 cm) wide x 14.0 (35.6 cm) high x 7.75 (19.7 cm) deep. Door: 24.125 (61.3 cm) wide x 14.25 (36.2 cm) high x (door adds 0.063 [approx. 0.16 cm] to depth), black. NFS-LBBR: Same as NFS-LBB above but painted red. Compliance with Codes and Standards The CHG-120 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems. UL 1481 Power Supplies for Fire Alarm Systems. CAN/ULC-S527-M87. Agency Listings and Approvals The listings and approvals below apply to the basic CHG-1 20. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S674. ULC: S635. FM: Approved. CSFM: 7315-0028:0189. MEA: 195-97-E, 345-02-E. FDNY: #6114. I I NOTIFIER® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I I ISO 9001 This document is not intended lobe used for installation purposes. We try to keep our product information up-to-date and accurate. - • • We cannot cover all specific applications or anticipate all requirements. llNI MIM1URIN QUALITY SYSTEMS All specifications are subject to change without notice. Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. I www.notifier.com - Page 2 of 2— ON-6040:A2 • 10/18/2012 1 Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 % deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard %"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information I I I I I SIGNALING '"FAD LISTED ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to. upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. ISO %P,01 - \ REGISTERED NFPA COMPANY Made ln\U.S.A. .1 Space Age Electronics, Inc. 2009 ED0549 LT10559 Rev.D 1/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! I I I SPACE AGE ELECTRONICS, INC. Specifications: The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector P,apn,ty Information MlnIn,a,,,Roq,I,dDocun,ntatIon (SIG-FUN) Ce,tlflcalionn and App,ovals 16.1 SystemInIOIIOtionCOnI,ndo, , a 6.5 Adho,5y Having jlaindk ion. Co,,Mo.,osIa,.aoo.,00n,q I,.*000,(. 00____ Equipment Information on.000l.utsia..o,g, eGa.ansllln ., 1T10644 R.n. I Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations Ordering Information: Part # Description (ssu00J685?j Fire Alarm Storage Cabinet RED I I I Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! SSU00686 Custom screening with your Logo Check out our Infinity line eFAD single gang 2 Gig digital storage solutions (IAMEFAD) This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0549 LT10559 Rev.D 2/2 I I I I I DN-6935:D • 1-1-202 i (FSP-8§i(A) Series NOTI Fl ER® Intelligent Plug-In Photoelectric 0 Smoke Detectors with FlashScan® by Honeywell I Intelligent/Addressable Devices General Notifier FSP-851 (A) Series intelligent plug-in smoke detectors with integral communication provide features that surpass con- ventional detectors. Detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. The FSP-851 (A) photoelectric detector's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the FSP- 851 T(A). The FSP-851 R(A) is a remote test capable detector for use with DNR(A)/DNRW duct detector housings. FSP-851(A) series detectors are compatible with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACP5). FlashScan® (U.S. Patent 5,539,389) is a communication proto- col developed by Notifier that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. if one of the devices in the group has new information, the panel's CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of earlier designs. Features Sleek, low-profile design. Addressable-analog communication. Stable communication technique with noise immunity. Low standby current. Two-wire SLC connection. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Optional remote, single-gang LED accessory. Dual LED design provides 3600 viewing angle. Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan systems only). Remote test feature from the panel. Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only). Built-in functional test switch activated by external magnet. Built-in tamper-resistant feature. Sealed against back pressure. Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. 94-5V plastic flammability rating. SEMS screws for wiring of the separate base. Optional relay, isolator, and sounder bases. Specifications Sensitivity: 0.5% to 2.35% per foot obscuration Size: 2.1' (5.3 cm) high; base determines diameter. - B21OLP(A): 6.1" (15.5 cm) diameter. - B501 (A): 4.1" (10.4 cm) diameter. - B200S(A): 6.875" (17.46 cm) diameter. \ r - (FsP-85A) in B2IOLP(A) Base - B200SR(A): 6.875" (17.46 cm) diameter. - B224RB(A): 6.2" (15.748 cm) diameter. - B224B1(A): 6.2' (15.748 cm) diameter. Shipping Weight: 5.20z. (147g). Operating Temperature range: FSP-851(A), 0°C to 49°C (32°F to 1200F). FSP-851T(A), 0°C to 38°C (32°F to 1000F). Low temperature signal for FSP-851T(A) at 45°F +1- 10°F (7.22°C +1- 5.54°C). FSP-851 R(A) installed in a DNR(A)/DNRW, -20°C to 70°C (-4°F to 1580F). ULIULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 m/ mm.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (57C). DETECTOR SPACING AND APPLICATIONS Notifier recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m) and higher. For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at system sensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 300pA @ 24VDC (one commu- nication every five seconds with LED enabled). LED Current (max.): 6.5mA @ 24 VDC ("ON"). Installation FSP-851(A) plug-in detectors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and remove detectors without using a ladder. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: I) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation DN-69350• 12/08/2011 —Page 1 0t2 I I Li I i I I I I I I I I I I sheet 156-1380 for device limitations between isolator modules and isolator bases. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ULListed:S1115. ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP-851TA). MEA Listed: 225-02-E. FM Approved. CSFM: 7272-0028:0206. Maryland State Fire Marshal: Permit #2122 BSMI: C1313066760036. CCCF: Certif. # 2004081801000017 (FSP-851 T) Certif. #2004081801000016 (FSP-851). U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B21OLP(A)). Lloyd's Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B21OLP(A)). Product Line Information NOTE: "A" suffix indicates ULC Listed model. Low-profile intelligent photoelectric sensor. Must be mounted to one of the bases listed below. FSP.851 A: Same as FSP-851 but with ULC listing. FSP-851T: Same as FSP-851 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-851TA: Same as FSP-851T but with ULC listing. FSP-851 R: Low-profile intelligent photoelectric sensor, remote test capable. For use with DNRAIDNIRW. FSP-851 RA: Same as FSP-851 R but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: For details on intelligent bases, see DN-60054. B21OLP(A): Standard U.S. flanged low-profile mounting base. B21OLPBP: Bulk pack of B21OLP; package contains 10. B501(A): Standard European flangeless mounting base. B501 BP: Bulk pack of B501; package contains 10. 13200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tempo- ral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form-C. Rating: 2.0 A @ 30 VDC resistive: 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B22461(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases ACCESSORIES F110: Retrofit flange to convert B21OLP(A) to match the B71OLP(A) profile, or to convert older high-profile bases to low- profile. Fl 1OBP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04.-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-01 0: Detector removal tool without pole. BCK-200B: Black detector covers for use with FSP-851 (A) only; box of 10. WCK-2006: White detector covers for use with FSP-851 (A) only; box of 10. -Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I I I I I I I I I I iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 9313=1=1 We cannot cover all specific applications or anticipate all requirements. EIIIIINE81INS & MMIKMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. I www.notifier.com Page 2 of 2— DN-6935:D • 12/0812011 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 27208ro2063 Page 1 of I CATEGORY: 7272 - SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC I LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 I Email: vladimir.kireyev©honeywell.com DESIGN: Models FSP-751, HPX-751, FSP-751T, FSH-751, FAPT-751, FAPT-851sR85:1 FSP851R* and FSP-851T photoelectric type smoke detectors. Models FSP-7511 and I FSP-851T employ a 135°F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances I and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible I base and fire alarm control units. Models FSP-751, FSP-751T, FAPT-751, FAPT-851, FSP-851, FSP851R*, FSP-851T are suitable for open areas and inside duct installation with air velocities between 0-4000 fpm. Model HPX-751 is suitable for open areas with air I velocities between 0-300 fpm. Model FSH-751 is suitable for open areas with air velocity between 0-4000 fpm. NOTE: Combined with 7272-0028:208 The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-07-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I DN-60054: E i Intelligent Bases M070 FO E 0 B501 (A), B200S(A), B200SR(A), 21OLP(A), B2241B1(A), B224RB(A), by Honeywell I Mounting Kits, and Accessories - I General Intelligent FlashScan® and CLIP mounting bases and kits pro- vide a variety of ways to install NOTIFIER detectors in any application. Intelligent detectors can be mounted in either flanged or flangeless bases depending on junction box selec- tion (see Junction Box Selection Guide). Across this product line, detectors plug in easily to the base with SEMS screws; and models employ various 12 to 24 AWG wire ranges. Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one Form-C contact relay for control of auxiliary functions such as door clo- sure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in temporal and non-temporal pattern versions depending on whether the signal is to be used for evacuation purposes. Specifications Diameter: - B501: 4.1(104 mm). - B224B1, B224RB, B21OLP: 6.1° (155 mm) - B200S/SR: 6.875° (17.46 cm). Wire gauge: - B224Bl, B224RB: 14 to 24 AWG. —B21OLP, B501, B2005/SR: 12to24AWG. Temperature range: - B224Bl, B224RB, B200S/SR: 32°F to 120°F (0°C to 49°C). - B210LP, B501: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F * 1.1°F) per ULC. However, the useful life of the sys- tem's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humid- ity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Electrical Ratings FOR B200S/SR: External supply voltage: 16 to 33 VDC (VFWR) Standby current: 500 pA maximum. Alarm current: - B200S: 25 mA maximum at high-volume setting; 15 mA maximum at low-volume setting. - B200SR: 35 mA maximum. SLC operating voltage: 15 to 32 VDC. SLC standby current: 300 pA. isç>) Flangeless Mounting Base Flanged Mounting Base B501(A) 21OLP(A) B200S(A), B200SR(A) B224RB(A) Sound output: measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone). - B200S, high-volume: Greater than 85 dBA minimum. - B200S, low-volume: Greater than 75 dBA minimum. - 6200SR: Greater than 85 dBA minimum. FOR B224RB, 82248!: Operating voltage: 15 to 32 VDC (powered by SLC). Standby ratings: <500 pA maximum @ 24 VDC. Set time (B224RB only): short delay 55 to 90 msec; long delay 6 to 9 seconds. Reset time (B224RB only): 20 msec maximum. Relay characteristics (B224RB only): two-coil latching relay; one Form-C contact; ratings (ULJCSA): 0.9 A @ 125 VAC, 0.9 A @ 110 VDC, and 3.0 A © 30 VDC. Product Line Information INTELLIGENT BASES B501: Flangeless mounting base. B501 A: Flangeless mounting base, ULC Listed. B501 BP: Bulk pack of B501 (10). (21OLPt Flanged mounting base. B21OLPA: Flanged mounting base, ULC listed B21OLPBP: Bulk pack of B21OLP (10). B200S: Intelligent addressable sounder base capable of pro- ducing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and cus- tom tone. B200SA: Same as B200S with ULC-listing. B200SR: Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. B200SRA: Same as B200SR with ULC-listing. I DN-60054:E • 7/22/2011 - Page 1 of 2 I B224RB: Relay base. B224RBA: Relay base, ULC Listed. B224B1: Isolator base. B224B1A: Isolator base, ULC Listed. MOUNTING KITS AND ACCESSORIES SMB600: Surface mounting kit, flanged. F110: Retrofit flange for converting high-profile bases to low- profile. F110BP: Bulk pack of F110 (10). F210: Accessory flange ring for B21OLP(A) base (new design). 6-inch diameter. F210BP: Bulk pack of F210 (10). RA100Z: Remote LED annunciator. RA100ZA: Remote LED annunciator, ULC Listed. M02-04-00: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR213: Detector removal tool for current heads (T55-127-010 included). XR2: Detector Remove Tool for use with low profile detector heads, and FSL-751. XP-4: Extension pole for XR2/B (5 to 15 ft/i .524 to 4.572 m). T55-127-010: Detector removal head. BCK-200B: Black detector kit, package of 10 (for use with photo and ion detectors). WCK-200B: White detector kit, package of 10 (for use with photo and ion detectors). Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S91 1 ULC Listed: S911 FM Approved MEA: 22-95-E, 205-94-F Vol. 2; 257-06-E CSFM: 7300-1653:0126, 7135-1653:0213, 7300-0028:0173, 7300-1653:0109 Junction Box Selection Guide Base Models Single Gang 3.5" Oct. 4.0" Oct. 4.0" Sq. 4.0' Sq. with 3.0' mud ring 50 mm 60 mm 70 mm 75 mm B200S, B200SR Yes Yes Yes Yes Yes No No No No B501 No Yes No No Yes Yes Yes Yes No Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes Yes Yes No No No Yes Yes NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. FlashScan®, NOTIFIER® and System Sensor® are registered trademarks of Honeywell International Inc. @2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EN11111111111111 & MMI1llIE All specifications are subject to change without notice. I I QUALITY SYSTEMS Made in the U.S. A. I For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-60054:E • 7/22/2011 1 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION I OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE CAL LISTING No. 1653:0109D Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyevhoneywell.com DESIGN: Models B401, B401 B, B401 R, B401 BR, B401 BR-750, B401 R-750, B402B, B40413, B404BT, B406B, B501, B501B, 14506587-002, B501BH, 13501BHT,B401BH, B110LP, B110RLP, B11ORLP750, B112LP, B114LP, B114LPBT, B116LP and(B210jdetector bases. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation and UL label. APPROVAL: Listed as detector bases for use with separately listed compatible detectors. NOTE: Formerly 7300-1209:128 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division C" BG2LT Addressable Manual Pull Station DN-6726: D • H-240 ?6) NOTIFIER® by Honeywell Intelligent/Addressable Devices The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except Fire Warden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/o) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. . Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on CLIP protocol loops. Up to 159 NBG-1 2LX stations per loop on FlashScan® pro- tocol loops. Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Th(NBG-I2LX, Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4 (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1-159 on FlashScan® systems, 1-99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or DN-6726:D.4/13/2012—Page 1 of 2 I 4 (10.16 cm) square electrical box, and shall be installed I within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. I Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. I The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. I Product Line Information (NBG120X Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-1/0: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. LJL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E. CSFM: 7150-0028:0199. FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). BSMI: C1313066760047. U.S. Coast Guard. Lloyd's Register. I . FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. I NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. @2012 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. iso 9001 We try to keep our product information up-to-date and accurate. 93M=1=1 We cannot cover all specific applications or anticipate all requirements. MINFE111111 9 WIRMIG All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-6726:1) • 4/1312012 I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7150-0028:0199 Page 1 of 1 CATEGORY: 7150 - FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: vladimir.kireyev@honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-1 2-LO, NBG-1 2LOB, NBG-1 2W, NBG-1 2LW, NBG-1 2NC, NBG-1 2WP, NBG-1 2LWP, NBG-1 NBG-1 2LA, NBG-1 2PS, NBG-1 2LSP, NBG-1 2LPS, NBG-1 2LPSP, NBG-12SP, NOT-BG12LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12L0, NBG-I2LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct JJ operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I I I (MR-i(A), FMM1O1 (A), FZM-1(A) &(FDM.1(A) Monitor Modules with FlashScan® DN-6720:C • H-220 NOTI FIE R® by Honeywell General Four different monitor modules are available for Notifiers intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). G~MMM-f(A) is a standard-sized module (typically mounts to a 4 [10.16 cm] square box) that supervises either a Style D (Class or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3 (3.302 cm) H x 2.75' (6.985 cm) W x 0.5 (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super- vises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. öM-T(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class tFfllItfI(A) (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. I I I DN-6720:C 1 10/06/2010 - Page 1 of 4 FMM.1 01 (A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. 1415 0 1 ADDRESS 0 1 l 10~. 2 1 -'" 2 1 5 11 LOOP ____ 8 7 8 76 I TENS ONES The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-1O1(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-1O1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensirig. Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65° (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. FZM-1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops, 01 —99 on CLIP loops. LED flashes during normal operation; this is a programma- ble option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1 (A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELA across terminals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.91K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4 (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2125° (5.398 cm) deep box. oil I Lu .jII _J Lu 11:3 0 ii Page 2 of 4— DN-6720:C • 10/06/2010 I __ I (.!pMI(A) Dual Monitor Module The FDM-1 (A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive I addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits I ONLY Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS I Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). I Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA I EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 320 to 120°F (0° to 49°C). I Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING I The FDM-1 (A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1 (A) is set to address "26", then it will automatically I assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-l(A) are 0, 2, 4, 6, 0r8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. IACAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only.- The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 FM Approved CSFM: 7300-0028:0219 MEA: 457-99-E U.S. Coast Guard: I I - 161.002/23/3 (AFP-200: FMM- 11-101, FZM- 1) - 161.002/42/1 (NFS-640: FMM- 11-101) Lloyd's Register: —03/60011/El (FMM-11-101, FZM-1) - 94/60004/E2 (AFP-200: except FOM- 1) —02/60007 (NFS-640: FDM- 1) FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 (NFS2-3030) Product Line Information NOTE: "A" suffix indicates ULC-listed model. çM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. b(A): Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. DN-6720:C • 10/06/2010 - Page 3 of 4 I I I I I I FlashScan® and NOTIFIERV are registered trademarks and FireWatchTm is a trademark of Honeywell International Inc. @2010 by Honeywell International Inc. All rights reserved. Unauthorized use I of this document is strictly prohibited. I iso goal This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. cma • • We cannot cover all specific applications or anticipate all requirements. lLlHlN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161 FAX: (203) 484-7118. I www.notifier.com I Page 4 of 4— DN-6720:C • 10/06/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. j002T0 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC, DEVICES I LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 I Email: vladimir.kireyevhoneywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM FMM-101, FZM-1, FSM-101,bM' I FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM.1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances I and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. I APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. I NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. I I I I I Rev. 10-24-11 mt I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I " an endorsement or recommendation of the item listed. operational requirements or installation criteria. Refer to This listing should not be used to verify correct listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division IF r o in Sy5!n5or SYSTEM $ SENSOR Selectable-Output Horns, Strobes, and Horn Strobes SpectrAlert' Advance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. I I Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. I Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30 75, 95, 110, 115 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MDL sync module Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. I I I Agency Listings SIGNAUNG TED APPROVED S401 (d,,,ne, horn strobes. ho,n,) 3023572 5551 2 (sothes) 0 MEA approved Undwr strobes) 77:22:-1653,186 -16S3-188 (horn strobes, M5A452-00-E chime strobes) 7135-1653 189 ho,n5Vh,n,e5) I I I SpectrAlert Advance General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 1718-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with he Sync.Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 175 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30, 75,95,110,115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector syslem.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern.These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder, The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 2/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12to18AWG Ceiling-Mount Dimensions (including lens) 6.8-diameter x 2.5 high (173 mm diameter x 64 mm high) Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5D (142 mm 119 9mm W x 64 mm D) Horn Dimensions 5.6L x4.TWx1.3D(142 mm Lxi 19 mmWx 33 mm D) Wall-Mount Back Box Skirt Dimensions (BBS-2, BBSW-2) 5.9 Lx 5.0W x 2.2 D (151 mm Lx 128 mm W x 56 mm D) I Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1 diameter x 2.2- high (180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions (sold as a 5 pack) (TR-HS, TRW-HS) 5.7- Lx 4.8W x 0.35' 0(145 mm Lx 122 mm W x 9 m D) Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRC-HS, TRCW-HS) 6.9- diameter x 0.35 high (175 mm diameter x 9 m high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. PS, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. 'I 605-0895-087 I I I I I I I I I I I I I I I I I I I UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 )raw (mA RMS), 2-Wire Horn Strobe, Standard Can DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA DC Input RMS), 2-Wire Horn 16-33 Volts 135 150 Strobe, High 177 Candela 185 Range (135-185 cd) FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal 1-ugh 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC FWR DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 75 Coded High 82 82 88 88 93 92 101 101 8 Coded Medium 78 78 85 85 90 90 97 98 95 Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe A05-0395-007 Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 SpectrAlert Advance Dimensions WJJ.L strobes Wall-mount II (1lII1;III.1'IIlIiTii7.x4 7.1- l2.25- Wall back box skirt Ceiling back box skirt I SpectrAlert Advance Ordering Information ... Wall Horn Strobes Ceiling Strobes I '2 2-Wire Horn Strobe, Standard cd*, Red SCR Strobe, Standard cd, Red P2RH 2-Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red \ 2-Wire Horn Strobe, Standard cd, White SCW Strobe, Standard cd, White I P2WH 2-Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White P4R 4-Wire Horn Strobe, Standard cd, Red Horns P4RH 4-Wire Horn Strobe, High cd, Red HR Horn, Red P4W 4-Wire Horn Strobe, Standard cd, White HW Horn, White I Wall Strobes Accessories SR Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red SRHt Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall, White I SW Strobe, Standard cd, White BBSC-2 Back Box Skirt, Ceiling, Red SWW Strobe, High cd, White BBSCW-2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes TR-HS Trim Ring, Wall, Red PC2R 2-Wire Horn Strobe, Standard cd, Red TRW-HS Trim Ring, Wall White I PC2RH 2-Wire Horn Strobe, High cd, Red TRC-HS Trim Ring, Ceiling, Red PC2W*f 2-Wire Horn Strobe, Standard cd, White TRCW-HS Trim Ring, Ceiling, White PC2WH 2-Wire Horn Strobe, High cd, White I PC413 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White U Notes: Add "-Pto model number for plain housing (no FlRE"nrarkir-ig on cover), e.g., P2R-P. Add "-SP" so model number for "FUEGO" marking on cover, e.g., P2R-SP. *"Standard cd' refers to strobes that include 15,15/75, 30, 75,95, 110, and 115 candela sertings."High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. I t"'\ C2009 System SYSTEM 3825 Ohio Avenue. St. Charles, IL 60174 SENSOR' Phone: 800-SENSOR2 . Fax: 630-377-6495 wera product inf—tim, McItAing the latest versim of this data sheet I I I I I I *Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. [7125-1653:018J Page 1 of 1 CATEGORY: 7125— FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P21R, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. 'K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..WBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8- 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. I I I 1 I I I I I I I I