Loading...
HomeMy WebLinkAbout2177 SALK AV; 165; AS070244; PermitPermit No: AS070244 Job Address: 2177 SALK AV Permit Type: SPRINK Parcel No: 2120210300 Lot #: 0 Status: ISSUED Applied 10/9/2007 Approved: 10/15/2007 10/20/21, 4:51 PM AS070244 Permit Data City of Carlsbad Sprinkler Permit Reference No.: 0 Issued: 10/15/2007 PC #: Inspector: Project Title: SPEC SUITE #165 T.I. FIRE SPRINKLER INSPECTION Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: RIO SD PLAZA II MASTER LLC C/O NEWPORT NATIONAL CORPORATION 1525 FARADAY AVE #100 CARLSBAD CA Fees ($) Add'I Fees ($). Total ($) 0 Balance ($) 65 0 65 0 i/i i. September 20, 2007 Sprinkler 41a MICROFAST® AND MicrofastHP® QUICK I KJ F16 l:II[.c1u.YM RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com DESCRIPTION Viking Microfast® and MicrofastHP11 Quick Response Pendent Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes and temperature ratings and K-Factors to meet design requirements. The special Polyester and TeflonO coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflone and Polyester coat- ings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV MUPPVW FM Approved: Class 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-H5407984C-PDA VAS Approved: Certificate G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved: Ref. No. 096e/03 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, and 0786-CPD-40130 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 41d and Design Criteria on page 41e for cULus and FM approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers 12282 and 12290 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pres- sure (HP) sprinklers can be identified by locating "250" stamped on the deflector. All other Part Nos. not mentioned above are rated to.a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on The Viking Corporation's Web site at http:llwww.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Pip Cap Attachment: Brass UNS-C36000 Ejector Spring (for Sprinkler 12104): Stainless Steel For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated Form No. F081296 Replaces page 41a-f, dated August 2, 2007. (Updated VdS Approval.) - Sprinkler 41 b September 20, 2007 MICROFAST® AND I FII I1G Mic rofastHP® QUICK R ESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order MicrofastO and MicrofastHPa Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflone = N Temperature Suffix (°F/0C): 135°/68° =A, 155°/68° = B, 175°/79° = D, 2000/930 = E, and 286°/141° = G For example, sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F168 °C temperature rating = Part No. 06662BA6 Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for coated and/or recessed sprinklers: Part No. 12144W/B** (available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIVE CAPS MUST USE WRENCH 12144W/13. **A 1A" ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast5 and MicrofastHP11 Quick Response Pendent Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Fla ts Protective Sprinker Cop 10896 Figure 1: Standard Sprinkler Wrench 10896W/B - Sprinkler Wrench 12144V/B* for installing coated and/or recessed pendent sprinklers with protective caps. ®®A 1/2' ratchet is required (not available from Viking). Carefully slide the wrench sideways around the protective cap, ensuring engage- ment with the sprinkler wrench flats. September 20, 2007 Sprinkler 41c MICROFAST® AND MicrofastHP® QUICK N IF(IIs1G:SPRINKLERS RESPONSE PENDENT The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient ' Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155°F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 00) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 41d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. ram Sprinkler 41 d September 20, 2007 ROFAST® AND fastHP® QUICK :W:4JJEMJrREiSP(0NSE PENDENT RINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs©vikingcorp.com Approval Chart Temperature KEY I I Microfast® and MicrofastHP Finish Quick Response Pendent Sprinklers Escutcheon (5 applicabIo} Maximum 175PSI (12 bar) WWP - Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base Part SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Number' NPT BSP U.S. metric2 Inches mm cULus4 FM° NYC- VdS LPCB CE Standard Orifice 06662B VK302 1/2 15 mm 5.6 80.6 2-1/4" 58 1 AiX, B1Y A3X, 133Y AiX, B1Y F3 A3X C3X, D3Y13 C3X, D3Y15 Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 AiX, B1Y A2X, 132Y AiX, B1Y -- -- E313 - 12104 VK352 3/4" 20 mm 8.0 115.2 2-1/4" 58 -- -- - F3 - -- -- 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 AiX, B1Y - AiX, B1Y A3 - -- - Small Orifice" 067181310 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 AiX, B1Y A2X AiX, B1Y -- -- -- - 06720B10 VK331 1/2" 15 mm 4.2 60.5 2-1/4" 58 AiX, B1Y -- AiX, B1Y -- -- -- - 06932B VK331 -- 10 mm 4.2 60.5 2-3/8" 60 -- -- -- A3 - F214 - Maximum 250 PSI (17 bar) WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base Part SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Number' NPT BSP U.S. metric2 Inches mm cULus4 FM NYC" VdS LPCB 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 AiX, B1Y - AiX - -- -- -- Maximum 250 PSI (17 bar) WWP Small Orifice" 1229010 VK342 1/2" 115 mm 2.8 40.3 2-3/16" 1 56 1 AiX, B1Y - AiX -- -- -- I - Approved Temperature Ratings A -135°F (57 °C), 155°F (68 °C), 175°F (79 °C), Approved Escutcheons °F °C), °F °C) 200 (93 and 286 (141 Approved Finishes B - 135°F (57 °C), 155°F (68 °C), 175°F (79 "C), 1 - Brass, Chrome-Enloy, White Polyester78, X - Standard surface-mounted escutcheon or the Viking °F °C) and 200 (93 C -155°F (68 °C), 175°F (79 °C), 200°F (93 °C), Black Polyester7'8, and Black Teflon"' Microfast'° Model F-i Adjustable Escutcheon12 Y - Standard surface-mounted escutcheon or the Viking and 286 °F (141 °C) D - 155 °F (68 °C), 175 °F (79 °C), and 200 °F 2 - Brass and Chrome-Enloy'° 3 - Brass, Chrome-Enloy, White Polyester8, Microfaste Model F-i Adjustable Escutcheon or recessed (93 °C) and Black Polyester8 with the Viking Micromatic5 Model E-1 or E-2 Recessed E - 155 °F (68 °C), 175 °F (79 °C), and 286 Escutcheon °F (141 °C) F - 155 °F (68 °C) Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. ° FM Approved for use only in wet-pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. cULus Listed as corrosion resistant. 8 Other colors are available on request with the same Listings and Approvals as the standard colors. Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. 10The sprinkler orifice is bushed. 11Accepted for use City of New York Department of Buildings, MEA Number 89-92-E, Vol. 16. 12The Viking Microfast'5 Model F-i Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 13(E Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. '(E Certified Standard EN 12259-1 EC-certificate of conformity 0786-CPD-40130. MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. September 20, 2007 Sprinkler 41 e MICROFAST® AND "4r11 I FII I4J I:II[.1.u.JM MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer to the Approval Chart on page 41d) cULus Listing Requirements: Microfast and MicrofastHP® Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Aooroval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699,- Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Size: 2-5/16' (58.7 mm) minimum 2-1/8' 2-1/2' (63.5 mm) maximum (54 mm) 1/2' NPT _ (15 rim) 2-1/4' 1-5/8' (58 mm) (41 mm) Pendent Sprinkler 06662B (VK30E) 1-3/4' (44.5 mm) Installed with a standard 1/8' surface- mounted escutcheon. (IiI) 2' II UI 1-1/2' (38,1 mm) (508 mm) \Ik J .2!! Minimum Maximum Installed with a Microfast Model F—i Adjustable Escutcheon Figure 3: Sprinkler VK302 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 1-3/4' (44,5 mm) Maximum 1-1/8' (28,6 mm) Minimum Sprinkler 41f September 20, 2007 ICROFAST® AND '411 Ki t:C:*jjMMrREiS1cP0NSE crofastHP® QUICK PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Road, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcsvikingcorp.com 2-1/8' Ceiling Opening Size: 2-1/8' (54 rim) 2-5/16' (58.7 mm) minimum (54 mm) 2-1/2' (63.5 mm) maximum Installed with a Micr'omatic Model E-1 Recessed Escutcheon ~Lj 1-1/8' (28.6 rim) (50.8 ) Minimum Maximum __________ Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler VK302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_081296 Replaces page 41a-f, dated August 2, 2007. (Updated VdS Approval.)