Loading...
HomeMy WebLinkAbout6023 INNOVATION WAY; ; FPC2018-0361; PermitPERMIT REPORT (City of Carlsbad Print Date: 10/21/2021 Job Address: 6023 INNOVATION WAY, # 200, Permit Type: FIRE-Construction Commercial Parcel #: 2132611400 Valuation: $0.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: CARLSBAD, CA 92009 Work Class: Fire Alarm Track #: Lot #: Project U: Plan #: Construction Type: Orig. Plan Check U: Plan Check U: Permit No: FPC2018-0361 Status: Closed - Finaled Applied: 11/05/2018 Issued: 11/27/2018 Finaled Close Out: 08/12/2021 Inspector: Final Inspection: Project Title: Description: EZOIC - BLDG A 2ND FLR & ROOF - FIRE ALARM TI Applicant: FPContractor: CVA SECURITY CHULA VISTA ALARM INC JAMES RODRIGUEZ 6175 PROGRESSIVE AVE, U STE 400 6175 PROGRESSIVE DR, U STE 400 SAN DIEGO, CA 92154-6647-SAN DIEGO SAN DIEGO, CA 92154-6648 (619) 585-9111 (619) 585-9111 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FIRE ALARM SYSTEM ADDITION - I IR1IA I EZOIC TENANT IMPROVEMENT BLDG A - 6023 INNOVATION WAY CARLSBAD, CA 92009 - - - FPC20I8-0361 6023 INNOVATION WAY #200 EZOIC - BLDG A - FIRE ALARM TI 2132611400 11/19/2018 FPC20I8-0361 FUEGO ENGINEERING & DESIGN INC PREPARED FOR: CHULA VISTA ALARM INC P.O. BOX 212731 6175 PROGRESSIVE AVE. SUITE 400 CHULA VISTA CA, 91921 SAN DIEGO, CA 92154 CELL: (619)610.8637 PHONE: 619-585-9111 OFFICE: (619)796-3360 - PROJECT: EZOIC TENANT IMPROVEMENT BLDG A - 6023 INNOVATION WAY CARLSBAD, CA 92009 Model Number Description CSFM# ES-200X FIRE LITE FIRE CONTROL PANEL (EXISTING) 7165-0075:0500 MMF-301 FIRE LITE ADDRESSABLE MINI-MONITOR MODULE 7272-0075:0185 CRF-300 FIRE LITE ADDRESSABLE RELAY MODULE 7272-0075:0185 RTSI51 KEY SYSTEM SENSOR REMOTE TEST/RESET STATION 7300-1653:0212 P2WL SYSTEM SENSOR HORN-STROBE WALL 7300-1653:0503 SWL SYSTEM SENSOR STROBE WALL 7300-1653:0504 P2WK SYSTEM SENSOR HORN-STROBE WALL, WP 7125-1653:0188 SWK SYSTEM SENSOR STROBE WALL, WP 7300-1653:0187 S . FUEGO ENGINEERING & DESIGNINC PREPARED FOR: CHULA VISTA ALARM INC P.O. BOX 212731 6175 PROGRESSIVE AVE. SUITE 400 CHULA VISTA CA, 91921 SAN DIEGO, CA 92154 CELL: (619) 610-8637 PHONE: 619-585-9111 OFFICE: (619)796-3360 S S S Intelligent Addressable FACP Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTMF). Features Listed to UL Standard 864, 10th edition Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator over AlarmNet Optional CELL-MOD or CELL-CAB-FL GSM Central Station Communicator over AlarmNet® Automated activation of the ECC-50/100 Emergency Command Center ECC-FFT Firefighter Telephone option Compatible with SWIFT® wireless devices Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address Four built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices Notification Appliance Circuit End of Line resistor matching Four programmable function keys for ease of maintenance Two programmable relays and one fixed trouble relay Built-in Programmer Integral 80-character LCD display with backlighting Real-time clock/calendar with automatic daylight savings control History file with 1,000 event capacity Addressable sounder base compatibility Multi-criteria detector (smoke, heat, CO) with programmable response Control module delay timer Automatic detector sensitivity testing (NFPA 72 compliant) Automatic device type-code verification Point trouble identification Waterfiow selection per module point Alarm verification selection per detector point DF-60957:B 8 Fire Lrre®Atarms Maintenance alert warns when smoke detector dust accumula- tion is excessive One-person audible or silent walk test with walk-test log and printout System alarm verification selection per detector point PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP Supports LiteSpeedTm and CLIP protocols SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire Single addressable SLC loop which meets NFPA Class B and Class A requirements 198 addressable device capacity (99 addressable detectors and 99 modules) Compatible with Fire-Lite's addressable devices (refer to the SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NA CS) Four independently programmable output circuits. Circuits can be configured for the following outputs: - Style Y (Class B) - Style Z (Class A) Silence Inhibit and Autosilence timer options Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability Selectable strobe synchronization per NAG 2.5 A special application, 250mA regulated, total power for NAGs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A with Communicator by Honeywell General The ES-200X is the latest intelligent addressable Fire Alarm Control Panel (FACP) from Fire-Lite Alarms. The ES-200X comes with a pre-installed communicator and supports up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the ES-200X programs just like Fire-Lite's other addressable products, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status.(alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicators Internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting Is available using the CELL-MOD or CELL-CAB-FL. DF-609573 • 3/6/2018 - Page 1 of 4 PROGRAMMING AND SOFTWARE Autofrogramming (iearr mode) reduces installation time Custom English labels (per point) may be manually entered or selected from an internal librar' file Two programmable Form-C relay outputs 99 software zones Continuous fire protection during online programming Program Check automatically catches common errors not linked to an' zone or input point OFFLINE PROGRAMMING: Create the entire program in your office using FS-TOols, a Windows®-based software package, and uplbad/download system programming locally. Offline program- ming fiquires an ethernet connection. FS-Tools is available on www.firelite.com. User- interface LED INDICATORS Fire Alarm (red) CO Alarm (red) AC Power (green) Supervisory (yellow) Trouble (yellow) Ground fault (yellow) Batterfault (yellow) Disabled (yellow) Mainteance (yellow) Commjnication (yellow) Alarm Silenced (yellow) F1-F4 Programmable Function Keys (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge Alarm Silence Drill (Manual Evacuate) Four (4) programmable function keys Reset (lamp test) PRODUCT LINE INFORMATION ES-200X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre-installed communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. (For ES-200XC, refer to DF-60958.) FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.firelite.com. CELL-CAB-FL/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the ES-200X. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- 75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional BB-55F for mount- ing. BAT Series: Batteries, see data sheet DF-52397. PRN Series: UL listed compatible event printer. Uses, tractor-fed paper. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps. COMPATIBLE ANNUNCIATORS ANN-SO: Remote LCD annunciator mimics the infoimation dis- played on the FACP LCD display. Recommended wire type is un- shielded. ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. ANN-110: LED Driver Module provides connections to a user sup- plied graphic annunciatof: (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure: (See DF- 6024 1.) ANNRLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-SIPG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. SD365: Addressable low-profile photoelectric smoke detector. Lite- Speed only. 5D3654V: Addressable low-profile photoelectric smoke detector. Ivory. LiteSpeed and CLIP mode. 5D3651: Addressable low-profile photoelectric smoke detector with thermal sensor. LiteSpeed only. S0365T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. LiteSpeed and CLIP mode. SD365R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. LiteSpeed only. SD365R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. Lite- Speed and CLIP mode. H365: Low-profile 135°F fixed thermal sensor. LiteSpeed only. H3654V: Low-profile 135°F fixed thermal sensor. ivory. LiteSpeed and CLIP mode. H365R: Low-profile, intelligent, rate-of-rise thermal sensor. Lite- Speed only. H365R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. LiteSpeed and CLIP mode. H365H1: Low-profile intelligent 190F/88*C fixed thermal sensor. LiteSpeed only. H365HT-IV: Low-profile intelligent 190F/88°C fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. Legacy Devices CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD3551: Addressable low-profile photoelectric smoke detector with thermal sensor. 5D355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. SD355CO: Addressable, low-profile device that provides fire, heat, and carbon monoxide (CO) detection. H355: Fast-response, low-profile heat detector. 7-7 9" Page 2 of 4— DF-60957:8 • 3/6/2018 S S P_.~ H355R: Fast-response, low-profile heat detector with rate-of-rise option. H355HT: Fast-response, low-profile heat detector that activates at 190°F188°C. AD355: Low-profile, intelligent, "Adapt" multi-sensor detector (13350LP base included). B200SR: Addressable sounder base. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. D355PL: InnovairFIex low-flow non-relay duct-detector housing; includes SD355R. DNR: lnnovairFlex low-flow non-relay duct-detector housing. (Order SD355R1SD365R separately.) DNRW: InnovairFIex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order SD355R1SD365R separately.) Addressable Modules MMF-300: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A)lDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style YIZ (Class BI A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0° (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-I2LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). ISO-6: Six-fault isolator module. Mount one or two modules in a BB- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE: LiteSpeed Wireless Gateway W-SD355: LiteSpeed intelligent, wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-SD355T: Intelligent wireless photo/heat detector. W-H355: LiteSpeed Intelligent wireless fixed-temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W-CRF: LiteSpeed Intelligent wireless relay module. W-BGI2LX: LiteSpeed Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the ES-200X, see the following data sheets (document num- bers): S0365 Series (DF-61010), H365 Series (DF-61011), A0355 (DF- 52386), BG-I2LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF- 52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 Series (DF-52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series! MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF- 52356), SD355!5D355T (DF-52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series detection devices such as the CP300/CP350, SD300(7)/5D350(T) and older modules such as the M300, M301, M302, C304, and BG-IOLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. DF.60957:13 • 3/6/2018 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges Intelligent Signaling Line Circuits................................................ Addressable device capacity ................................. ................. 198 NFPA Standards Programmable software zones................................................. 99 The ES-200X complies with the following NFPA 72 Fire Alarm Sys- Annunciators ............................................................................. 16 tems requirements: - LOCAL (Automatic, Manual, Waterfiow and Sprinkler Supervi- Electrical Specifications sory). - AUXILIARY (Automatic, Manual and Waterfiow) (requires AC Power: 120/240 VAC, 50/60 Hz, 3.25 A. Wire size: minimum 14 4XTMF). AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, super- REMOTE STATION (Automatic, Manual and Waterfiow) vised. 1 - Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For Capacity: 7-18 AH (ES-200X cabinet holds maximum of two 18 AH reverse polarity signaling of alarm and trouble, 4XTMF is batteries.) required.) Communication Loop: Supervised and power-limited. - PROPRIETARY (Automatic, Manual and Waterfiow). Notification Appliance Circuits: Terminal Block provides connec- - CENTRAL STATION (Automatic, Manual and Waterflow, and tions for four NACs, Style V (Class B) or Style Z (Class A). Special Sprinkler Supervised). Application power. Power-limited, supervised circuitry. Maximum - OT, PSDN (Other Technologies, Packet-switched Data Net- signaling current per circuit: 2.5 amps special application, 250mA work) regulated. End-of-Line Resistor: 4.7k ohm, % watt (P/N 71252 UL - IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). listed) for Style Y (Class B) NAC; system capable of 1.9 kQ -22 kQ - CBC 2007 (Seismic) ELR range. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. - - • - - - - - Two Programmable Relays and One Fixed Trouble Relay: Con- agency Listings and Approvals tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). The listings and approvals below apply to the basic ES-200X control Form-C relays, non-power-limited, non-supervised, panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be In process. Consult factory for Cabinet Specifications latest listing status. Door: 19.26° (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72° UL: S624 (1.82 cm.) deep. Backbox: 19.00° (48.26 cm.) high x 16.65° (42.29 FM approved cm.) wide x 5.25 (13.34 cm.) deep. Trim Ring (TR-CE): 22.00° CSFM: 7165-0075:0500 (55.88 cm.) high x 19.65° (49.91 cm.) wide. FDNY: COA#6261 Shipping Specifications NOTE: See DF-60958 for ULC-fisted model. Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5° (57.15 cm.) wide x 8.5" (21.59 cm.) deep. AlarmNet®, Fire-Lite® Alarms, SWIFT®, and System SensorS are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. This document Is not intended to be used for Installation purposes. We try to keep our product Information up-to-date and accurate. Iso 9001 We cannot cover all specific applications or anticipate all requirements. ____ All specifications are subject to change without notice. :b U .J a 0 Uuii'iT'SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Country of Origin: USA www.firelite.com Page 4 of 4— DF-60957:B -31612018 I -] CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0500 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneyweltcom DESIGN: Models ES-50X and ES-200X Addressable Fire Alarm Control Units. Automatic, manual, waterfowl, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. The ES-50X is a compact version of the ES-200X. The ES-50X has 50 addressable device capability and 2 Notification Appliance Circuits with a 3.0 amps total 24VDC output in Alarm. The ES-200X has 198 addressable device capability and 4 Notification Appliance Circuits with 3.0amps total 24VDC output in Alarm expandable to 6.0amps with Model PWRMOD24. The Model IPOTS-COM provides Phone and IP communication. Models ES-50X and ES-200X system components are as follows [POTS-COM POTS and IP Communicator 4XTMF Transmitter Module ANN-80 Remote Annunciator Module ANN-100 Remote Annunciator Module ANN-I/O LED Driver Module ANN-S/PG Serial/Parallel Interface Module ANN-RLY Form-C Relay Module ANN-LED Annunciator Module ANN-RLED Annunciator Module CELL-MOD GSM Communicator DP-ES-R Dress Panel Model ES-200X system components are as follows: PWRMOD24 NAC Power Expander Module Refer to the listee's data sheet for additional detailed product description and operational considerations. RATING: 120/240Vac 50/60Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units, emergency alarm system control units and process 01-31-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed.. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other S Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0075:0500 Page 2 of 2 management equipment for use with separately listed compatible initiating and indicating devices. Refer to Manufacturers Installation Instruction Manual for details. NOTE: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. 01-31-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 3O,2019 is Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division S df-52121:b• E-325 MMF.300(A) Series, MDF300(A) jJ Flre•LuTeALarms Addressable Monitor Modules by Honeywell I .......................... . General Four different monitor modules are available for Flre'Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 is a standard-sized module (typically mounts to a 4° [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. MMF-301 is a miniature monitor module (a mere 1.3° (3.302 cm) H x 2.75" (6.985 cm) W x 0.5° (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind the device it monitors. MMF-302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF.300 Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each mod- ule Is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Cir- cuit (I DC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used to replace M300 modules in existing systems. MMF-300 APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class J, I MMF-300 (Type H) A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300 OPERATION Each MMF-300 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-300 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Maximum operating current: 375 hA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125° (5.398 cm) deep box. MMF-301 Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. df-52121:b. 11/13/08—Page 1 of 4 1415 0 1 ADDRESS o 1 13()2 1 2 ? LOOP 10 5 I 7 61 9 8 76 I TENS ONES oil 11w Il4 uQJ 110 - I 10 I il II iI The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- ing. The MMF-301 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm devices. The MMF-301 can be used to replace M301 modules in exist- ing systems. MMF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301 OPERATION Each MMF-301 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). MMF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 hA. Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65° (1.651 cm) deep. Wire length: 6° (15.24 cm) minimum. MMF.302 Interface Module LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. MMF-302 APPLICATIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302 OPERATION Each MMF-302 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-302 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 VA (LED flashing). EOL resistance: 3.91K ohms. External supply voltage (between Terminals 13 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125° (5.398 cm) deep box. MDF.300 Dual Monitor Module The MDF-300 Dual Monitor Module is intended for use in intel- ligent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel-controlled LED. NOTE: The MDF-300 provides two Class B (Style B) IOC circuits ONLY. Class A (Style D) 10C circuits are NOT supported in any application. MDF-300 SPECIFICATIONS Supports compatible two-wire smoke detectors. Normal operating voltage range: 15 to 32 VDC. Supervises IDC wiring and connection of ext Maximum current draw: 6.4 mA (LED on). source. __!7±Maximum ooeratlna current: 750 uA (LED flashino. High noise (EMF/RFI) immunity. 10 • SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 — 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation. Page 2014— df-52121:b ° 11/13/08 Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 320 to 120°F (00 to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. S MDF-300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address '26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300 are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S3705 ("A" suffix models) FM Approved CSFM: 7300-0075-185 MEA: 72-01-E Product Line Information NOTE: "A" suffix indicates ULC Listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. df-52121 :b • 11/13/08 - Page 3 of 4 FireLite® and LiteSpeed® are registered trademarks of Honeywell International Inc. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. 13M • . . We cannot cover all specific applications or anticipate all requirements. Bilr&MIN; & MANIMINIIIIING All specifications are subject to change without notice. QUALITY SYSTEMS Made ln the U.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— df-52121:b • 11/13/08 I DIP ccc 0 CRF-300(A) df-60379:A1 • E-400 CRF.300(A) Relay Module (a Flre.uTeALarms by Honeywell The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTM is a communication protocol developed by Fire'Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. intelligent devices communicate in a grouped fashion. if one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically Identifies these devices to the control panel. internal circuitry and relay powered directly by two-wire SLC loop. integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 .iA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. High noise immunity (EMF/RFI). • Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 —99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls Include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4 (10.16 cm) square x 2.125° (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5ms) Coded 30 VDC 0.5 A Inductive (UR2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A df-60379:A1 ° 08/04/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA:72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. S LfteSpeed is a trademark and Fire-Lite® Alarms Is a registered trademark of Honeywell International Inc. C2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. This document Is not intended to be used for Installation purposes. Iso 9001 We try to keep our product Information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENINEING A MMIIAC1URINA All specifications are subject to change without notice. QUALITY SYSTEMS Made lnthe U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.flrelite.com Page 2012— df-60379:A1 • 08(04/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 - Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev@Honeywell.com DESIGN: Models MDF-300,(MMF-301 ,)MMF-300, MMF-302, MCF-300 monitor modules; Models (CRF-300 nd CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: S *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2018 . Listing Expires June 30, 2019 Authonzed By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM SENSOR Duct Smoke Detector Accessories Expand the versatility of the lnnovairFlex" line of duct smoke detectors with System Sensor notification and test accessories. SMOKE Available Accessories Duct smoke detector accessories add functionality to the duct APA1 51 Piezo Annunciator smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All MHR Mini-Horn, Red System Sensor duct smoke detectors and accessories are UL listed. MHW Mini-Horn, White The APA1S1 piezo annunciator, which replaces the APA451 with RA1 OOZIRA100ZA Remote Annunciator a new, improved look, provides an audible alarm signal, a red LED RTS151 Remote Test Station to indicate alarm status, and a green LED to indicate power status. RTS151KEY Remote Test Station with Key It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to RTS2 Multi-Signaling Accessory comply with NFPA 90A. ADS Add-On Strobe The MHR and MHW SpectrAlert Advance mini-horns feature RTS2-AOS Multi-Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTS151 and RTS151 KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS1 51 KEY test Station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2-AOS multi-signaling accessories are designed to work with InnovairFIex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push Agency Listings button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The ADS (Add-On Strobe) is an optional accessory included with the RTS2-AOS model. LISTED APPROVEO Specifications, Duct Smoke Detector Accessor APA1 51 Piezo Annunciator Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49°C (32°F to 120°F) Relative Humidity 10 to 93% non-condensing Wire Gauge 12 to I8AWG Dimensions 4.6H x 2.9Wx .45D Voltage Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or FWR Operating Voltage 8 to 33 VDC (9 to 33 VDC with Sync-Circuit' Module) Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC 17 mA RMS max. at 8 to 173 Volts FWR 29 mA RMS max. at 16 to 33 Volts DC 25 mA RMS max. at 16 to 33 Volts FWR Temperature Range 0°C to 49°C (32°F to 120°F) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3 kHz Wire Gauge 12to18AWG Dimensions 4.6'H x 2.9W x 0.45'D Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 12 mA Dimensions 4.6 - H x 2.8W x 1.3'D ies Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Test Switch 10 VA @32 VDC Reset Switch 10 VA @32 VDC Alarm Response Time 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14t0 18AWG Dimensions 4.8Hx2.90YWx1.4D RTS 151 KEY -Remote Test Power Requirements Station wit h Key Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current 105 mA max. Alarm ResponseTime 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14to18AWG Dimensions RTS2 and-RTS2-AOS Multi Voltage 4.6'Hx2.75Wx1.80 -signaling Accessory 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8Wx5.3Hx 1.6D S For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. I SMOKE T1. LL* RTS151 ULS4O11 RTS151 KEY ULS2S22 APA151 UL54011 RTS2-AOS UL S2522 RA100Z UL S2522 MHW UL S4011 MHRULS4O11 AOS SYSTEM 3825 Ohio Avenue. St. Charles, IL 60174 wdwge C2OIO System Senso • .*W .tc mnon l SENSOR' Phone: 800-SENSOR2 Fax: 630-377-6495 w50423-OO1 -2/10. #2309 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL • FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: Models RTS151[RTS151and RA100Z Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. S 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM SENSOR Indoor Selectable. Output Horns, Strobes, and Horn Strobes for Wall Applications R E System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on wall units: 15, 30, 75, 95, 110,135, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices Compatible with MDL3 sync module Listed for wall mounting only The System Sensor L.Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING APPROVED USTED S5512 FM approved except S 7125-16530504 $4017 for ALERT models 7135-1653:0553 3057383.3057072 r Specifications i Arch itect/Enquneer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync'Circuit'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1'2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6L x 4.7W x 1.91"D (143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" Lx 3.46" W x 1.91" D (133 mm Lx 88 mm W x 49 mm D) Horn Dimensions 5.6L x 4.7W x 1.25D(143 mm Lx 119 mm W x 32 mm D) Compact Horn Dimensions 5.25 Lx 3.45W x 1.25" D (133mm Lx 88mm W x 32mm D) Full Wave Rectified (RNR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. 0 UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 O UL Current Draw Data UL Max. Strobe Current Draw (rnA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.lKTemporal High 93 156 53 73 119 140 164 190 242 3.lKTemporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts - - FWR Input 15cd 30cd 75cd 95cd llOcd 135cd 185cd Temporal High • 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9. Coded High 85 90 90 S 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. Horn L-Series Dimensions 1.91 Is— 3.46 —1 1.25 5.27 U Compact Strobe I Horn Strobe 3.46 L i 1.25 Le00 .27 .00000010,00i 600000, 0000 Compact Horn S L-Series Ordering Information Wall Horn Strobes Horns P2RL 2-Wire, Horn Strobe, Red HRL Horn, Red P2WL 2-Wire, Horn Strobe, White HWL Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL Compact Horn, Red P2GWL 2-Wire, Compact Horn Strobe, White HGWL Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBRL Wall Surface Mount Back Box, Red Wall Strobes SBBWL Wall Surface Mount Back Box, White SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have FUEGO" marking on cover All -ALERT models have "ALERT" marking on cover 5ys7Epu7 3825 Ohio Avenue • St. Charles, IL 60174 52017 System San=. • Phone: 800-SENSOR2 • Fax: 630-377-6495 Product opecificatisnu subject to chango w13r0ut notice. tosS systernuensoccom SENSOR www.systemsensor.com AVoS865o3 • 03/17 for Current product information, inctudng the blest version at this data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135 --AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.KireyevhoneywelI.com DESIGN: System Sensor Indoor 2-wire and *4wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, .P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and P4WL Wall Horn Strobes; PC2RL,PC2WL, PC4RL and *pC4wL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, . Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. Walilrim Rings: *TR2 and *TR2W CeilingTrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2018 Listing Expires' June 30, 2019 Authorized By: DAVID CASTLLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDCIFWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAWD CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: .System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyev@honeywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. S Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2018 Listing Expires' June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. 02-14-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authonzed By: DAVID CASTILLO, Program Coordinator Fire Engineering Division O SYSTEM $ SENSOR Outdoor Selectable- Output Horns, Strobes, and Horn Strobes SpectrAlert"' Advance outdoor selectable-output horns, strobes, and horn strobes are rich with features that cut installation times and maximize profits. 9 104 1 U - LPM S 00 P Features Automatic selection of 12-or 24-volt operation at 15 and 15/75 S candela Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150,177,and 185 Plug-in design with minimal intrusion into the back box Tamper-resistant construction Universal mounting plate for wall- and ceiling-mount units Mounting plate shorting spring tests wiring continuity before devices are installed Weatherproof per NEMA 4X, IP56 Listed to UL 1638 (strobe) and UL 464 (horn) Rated from —40°Fto 151°F Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Compatible with System Sensor synchronization protocol and legacy SpectrAlert products Agency Listings . MEA SIGNAUNG 653:187 (outdoor strobes) USTED 5401 (chimes, horn strobes, horns) APPROVED approved 7125-1653.1885-0" 51,0bps. chime strobes) 53593001400, and alert strobes) 3023572 MEA452.05-E 7135-1653:189 (horns, chimes) The SpectrAlert Advance series offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. SpectrAlert Advance outdoor horns, strobes, and horn strobes can be used indoors or outdoors in wet or dry applications, and can provide reliable operation from —40°F to 151°F. Like the entire SpectrAlert Advance product line, these devices include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. All horns, strobes, and horn strobes use a universal mounting plate with an onboard shorting spring that tests wiring continuity before the device is installed, protecting devices from damage. In addition, field-selectable candela settings, automatic selection of 12-or 24- volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Arch itect/Engineer Specifications 0 General SpectrAlert Advance outdoor horns, strobes and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110,115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ________ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per ULThe strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DCJFWR or regulated 24 DCJFWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24V nominal) InputTerminai Wire Gauge 12to18AWG Ceiling-Mount Dimensions (including lens) 6.8 diameter x 2.5 high (173 mm diameter x 64mm high) Wall-Mount Dimensions (including lens) 5.6'L x 4.7'W x 2.5'D (142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6Lx4.7'Wx 1.3D(142 mm Lx 119mmWx33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) ST Lx 5.1 -W x 2.0' D (145 mm Lx 130 mm W x 51 mm D) Ceiling-Mount Weatherproof Back Box Dimensions (SA-WBBC) 7.1 diameter x 20' high (180 mm diameter x 51 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0456.c02 Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Standard 15 123 Candela Range 15/75 142 30 NA 75 NA 95 NA 110 NA 128 66 71 148 77 81 NA 94 96 NA 158 153 NA 181 176 NA 202 195 115 NA NA 210 205 . UL Current Draw Data IUL Max. Strobe1 ICurrent11Drawl(mAIYLl Ii 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 IllL Max. Current i II r. StandardLCandela Range (15-IItI 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low . Non-Temporal High 129 151 76 86 101 160 184 194 201 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For 1< series products used at low temperatures, listed candela Horn and Horn Strobe Output (dBA) ratings must be reduced in accordance with this table. - - - ')A-%I-I. M.......I Strobe OutputIjU Listed Candela Candela rating at -40°F 15 Do not use below 32F 30 15/75 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Switch Position Sound Pattern dB o—II. Volts DC FWR 10—j Volts DC FWR Reverberant DC FWR Anechoic DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2-wire horn strobe. AOS0455-002 SpectrAlert Advance Dimensions R FA Is 51' if Wall weatherproof back box fl- 2.5' I Ceiling-mount horn strobes 2 O Ceiling weatherproof back box SpectrAlert Advance Ordering Information Wall HornStrobes CeilingHornStrobes P2RKt2-Wire Horn Strobe, Standardcd, Red, Outdoor PORK 2-Wire HornStrobe, Standard cd, Red, Outdoor P2RHK 5 2-Wire HornStrobe,High cd, Red, Outdoor PC2RHK 2-Wire Horn Strobe, High cd, Red, Outdoor P2WK*f2-Wire Horn Strobe, Standardcd, White, Outdoor PC2WK2-Wire, HornStrobe, Standard cd, White, Outdoor P2WHKt2-Wire Horn Strobe, High cd, White, Outdoor PC2WHK2-Wire, HornStrobe High cd, White, Outdoor P4RK5 4-Wire Horn Strobe, Standard cd, Red, Outdoor PC4WK4-Wire, Horn Strobe, Standard cd, White, Outdoor P4WK 4-Wire HornStrobe, Standardcd, White, Outdoor PC4WHK4-Wire, Horn Strobe, High cd, White, Outdoor P2RHK-1 202 -Wire Horn Strobe, Highcd, Red, Outdoor,120 V CeilingStrobes Wall Strobes SCRK Strobe,Standard cd,Red, Outdoor 5RK 5 Strobe, Standard cd,Red, Outdoor SCRHKStrobe, Highcd, Red, Outdoor SRHK*tStrobe, High cd,Red, Outdoor SCWKStrobe, Standard cd, White, Outdoor SWKtStrobe, Standardcd, White, Outdoor SCWHKStrobe, Highcd, White, Outdoor SWHK*f Strobe, High cd, White, Outdoor Horns HRK Horn,Red, Outdoor Notes: Add '-P'to model number for plain housing (no 'FIRE' marking on cover), e.g., P2RK-P. t Add '-R'to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WI? and WTPW. 'Standard cd"reters to strobes that include 15,15/75, 30, 75,95, 110, and 115 candela serrings,'High cd'refers to strobes that include 135,150,177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM $ SENSOR' 3825 Ohio Avenue. St. Charles, IL 60174 Phone: 800-SENSOR2 . Fax: 630-377-6495 C29 System Sensor. Prodon5speons subject socSrango wthotit nnsentoinronnaindedrng the lreotseoion of this dots sheet A05.0456.022.11109. fl55 uolswiu-j 6uu09u15u3 eiIj ioeuipi000 weJ5oJd 'oriusvz ainva :AG pzuoqny 610Z IOE eunr saildx3 5u.'is11 8IO 'o Apr :penssl ewa Jamb Jo/RUB SU0ipt1J4SUi uo!eiiisui aaqs eep s,aas ol J.J9 euajij3 UO!eIIe4SUi JO s4UaWaJ!nbeJ ieuoiwjado I09JJ0 A4!JOA oj pasn aq jou pjnoqs 6uiSii sail -palsil wasl aqj 10 uoljepuawwooe.i io juawasiopue ue jou Si 6uiis1i S!14.j. swielo Aue jo UOi4e3iJUaA juapuadapui ue aeW 40U seop jnq ejep jamo ioipue SIflS9J Isal am pamaiAoi semi gels 6uuaau16u3 aild VUS0 we3ldde aql Aq pawwqns eep leo!uqoal uodri peseq si 6uisii s!qi tiq -si- paiQaJJO3. Sl!eP JOJ lBflUBLAJ uoipnilsul uoilelielsul SeeS!I 04 iejej uOIl!P3 01.0 L VddN m!M eouepiooe U! (uo!1en3eAe 1B404 io) 18U6!S uoilenDeA3 wJeW 9JI=l UJ84E leiodwel aqipne asjnd-99j4j en!ou!s!p a4l 84eJ0ua6 UBO seqoJs/ewiqo .io seqoJ/wo Aiuo esn Joopul pue epow 94eAijd jol eqeins si uoies ew!43 4unow IIBM io 6Uil!ab esn .ioopno io .ioopui ioj eqeins aie X!JjflS - 44iM SGOJ4S/WO s4!un ioJuoo wieie aig eiqwdwoo palsil Ale4eJedes q4IM pasn uaqm suoie3ildde peJ!edw! 5uieaq aq .ioj wawdinbe pue seoue!ldde 6u11eu6is jol eqe!ns seqoJjs/ewimp .io seqoisiwoq se pejsi- :-WAOddy Ieqei in pue 6u!4eJ eoupea Jeqwnu japow eweu S8a45fl :jyjj uoqoipsunl 6u!ne4 Apioq;ne em 04 ejqedeooe ieuuew e Ui pue se3ueuipio pue sepoo eqeoidde SuoI43nJ4sui uo!4ellesui pe4uUd s,ees m!M eouepi000e u :NOIj1VjSNI M/3A M9 1, S80J1/UJ0H (10 I-i JMd/OA cc-gi o 91I. - g seqoJ4/ewiq3 pue S0Jj9/UJ0 piepueg :pjyj suo!4eJep!suoo leUcReJedo pue uoid!Josep lonpoid PIIB49P leuo!!ppe J0j Jqqqs eep s,ee4s11 01 ieaj (6uiiie) M08M-vs. pue (6uiiie) o9M-vS (IleM) MGM-YS (heM) 99M-vS siepow sexoq peq looid jaqleam iosueg walsAs eq m1!M pasn UeqM x VLJ2N peei We PUB (3099+ 01 o.o -) J. 1.9 1.+ o wojj seJn4eJedwe4 e SU0leO!dde J00Pfl0 jol eqe!ns BiB sepow Xfl5 , 6u!Je4al OU IM 6uisnoq weld JOJ ,, X!Jns Aq pamollol eq Aew Jo BSfl J00Pfl0 io Joopu! 6uqeipui ,>, XijjnS aqj Aq POMOIIOJ eq IeW S8pOJ pe4e0!pui eSIM iamflo sseun Aiuo esn JOOpU! JOJ pepUe4Ul eie siepow liv eJnsopue punoi edA4 ai!M-Jnoj .seqOJIS/uJOH HMi'od pue H3d Mod V-3d siepo,g eJnsopue Jeln6ue4oeJ 'adA eJ!M-ifloi saqoJ/woH HMt7d PUB Hi'd Md d 9I8POtJ ainsopue punoi 'adA4 eJ!M-oM seqoJ9/uJoH HM3d PUB HJ3d M3d 3d sapoj aJnsopue Jein6uepei 'adAl BJIM-0M S80J49/UJ0H HMd pue HZd Md d sapoj seqoJ/ew!q3 MSHO pue HSHO siepovi WOO' hIeMAeUoq©AeAaJ!NJ!w!pelA :I!ew3 60CL-8t' (cog) XBd LLZ9-t'8 (coz) A9AaJ>4 liwipehA :peUo3 1.09 1 selJeq3 eAy o!qo ggCoUI pul jlamA9uOHo ij pa4eJodJoou!ufl Josues wescg :3111 U11VdLPl ONftJV3H 31-11 lOd S331A30 V1Iv1V 381-1 -- 91.L :Q003j'3 1. jo I. 868d 991.O99 -9I.L 0N ONIISI1 33IMI3S ONI1Sfl VJV1OOId ONI1Sfl SiVlIJ.VW 9NIOiIfl9 - ONIHNION3 3th iVHSIVtN Mild 31VJ.S H1 dO 331±10 N0l1331O1d 3JId '9 AIJ.S3IOd 10 iN3lNJ.IVd3a VINH0dIiV3 601) C S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL a; . FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 6 LISTING SERVICE w4~ LISTING No. 7300-1653:0187 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir.Kireyev©honeywell.com DESIGN: Models SWK, SWHK, SCWK, SCWHK, SRK, SRHK, SCRK and SCRHK strobe lights intended for indoor or outdoor use and may be mounted on the wall or the ceiling. These strobe lights are suitable for outdoor use at an operating temperature range of -40°F to 150°F (-40°C to 66C)* rating and are NEMA 4X rated when used with the Listed models SA-WBB (wall), SA-WBBW (Wall) or the model SA-WBBC (ceiling), SA-WBBCW (Ceiling) weatherproof back boxes. May be followed by suffix -P for plain housing with no lettering. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights for general signaling. For indoor or outdoor use. Refer to listee's S Installation Instruction Manual for details. NOTE: Not approved for public mode and not to be used as an evacuation signal for the hearing impaired. *Corrected 07-22-10 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division