Loading...
HomeMy WebLinkAbout6023 INNOVATION WAY; ; FPC2018-0377; Permit4bty of PERMIT REPORT Carlsbad Print Date: 10/21/2021 Permit No: FPC2018-0377 Job Address: 6023 INNOVATION WAY, CARLSBAD, CA 92009 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132611400 Track #: Applied: 11/21/2018 Valuation: $0.00 Lot #: Issued: 12/10/2018 Occupancy Group: Project #: Finaled Close Out: 08/12/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: LIFT SPEC SUITES -SPRINKLER TI (71 HEADS) SUITES 110, 120, 130, 140 Applicant: FPContractor: INDUSTRIAL FIRE SPRINKLER CO INDUSTRIAL FIRE SPRINKLER CO INC STEVE SCOTT 3845 IMPERIAL AVE 3845 IMPERIAL AVE SAN DIEGO, CA 92113-1702 SAN DIEGO, CA 92113-1702 (619) 266-6030 (619) 266-6030 x107 FEE AMOUNT FIRE NFPA 13 or 13R System' 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: '$0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov INDUSTRIAL FIRE SPRINKLER CO., INC. CA LIC.C-1 6 558084 HI LIC. C-20351 Co LIC. 11-1058 UT LIC. 7336958-5501 VA LIC. 2705 125390A LIFT SPEC'SUITES 6023 Innovation Way Carlsbad,. CA.' CONTENTS Material Cut- Sheets 3845 Imperial Ave., San Diego, CA., 92113 • Phone (6.19) 266-6030 • Fax (619) 266-6035 Page 1 of 4 NJI 1(J1p1®MICROFAST@ QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = 0, 200°/93° = E, and 286°/141 = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. I Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 4 "II I KjF1Gi®MICROFASTO QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1 :AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 F (65 C) Green High 286 °F (141 °C) 225 ¶ (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap-----." Wrench Flat ., , Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_052114 17.10.05 Rev 17.1 Page 3 of 4 MICROFAST® QUICK 'J I III'1G ® I:ll['Lw RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart i(UL) Temperature KE I I Microfast Quick Response VfX Finish A I Y ) I 4— Escutcheon (if applicable Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals' SIN ___ Number' _ _______ U.S. I metric2 Inches mm cULus LPCB NYC8 CE NPT I BSP 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 NOTICE 56 VdSJ Al, B2 -- -- See footnote 7 tJ PI :r I ' Limited 7177 riyii ?17F1.JI Office) I VK300 1 1/2" I 15 mm I 5.6—T--806 2-3/16 56 1 Al, B2 I -- -- Isee footnote 7.1 -- Approved Temperature Ratings Approved Finishes A- 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 1 - Brass, Chrome, White Polyester5'6, and Black Polyester56 286°F (141°C) B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT6 Footnotes I Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 17.10.05 Rev 17.1 Page 4 of 4 ® MICROFAST® QUICK ''SJ II(ItIG III[sLU'7MA RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY 'I Microfast® Quick Response - I Fnsh AIX4—Escutcheon(ffapp)icable)i Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN (Refer also to Design Criteria below.) NPT I BSP U.S. I metric2 Inches mm 12978 VK300 1/2 15 mm 5.6 I 80.6 2-3/16 56 Al, B2 NOTICE - Product Below - Limited Availability 7T1lLocal Viking t.Jifl 06661B VK300 1 1/2" 1 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 1 - Brass, Chrome, White Polyesters, and Black B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Polyester5 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Aporoval Requirements: The Microfast'5 Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. I Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2 (Replaced wrench 10896W/B with 21475M/B) Page 1 of 6 "J I KJF1Gi®MICROFAST@ QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 I Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION I The Viking MicrofastO Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors I are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. I 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 [} VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 I A LPCB Approved: Certificate 096e/06 CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). I Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 ' Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 I For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate I suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G I Form No. F_033314 18.06.21 Rev 18.1 Replaces Form No. F_033314 Rev 17.1 (Updated MED approval; added LPCB certificate number) Page 2 of 6 MICROFAST® QUICK N I I(IIS1G® III[siU'1M.. RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 00) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2 ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Wrench Flat clip Protective Sprinkler - .- Cap Figure 1: Standard Sprinkler Wrench 10896W/B I I I I I Form No. F_033314 18.06.21 Rev 18.1 I I I I I I I I I Page 30f6 NIKJNG* @ MICROFAST® QUICK l.iII[.flU'7W RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLEV/.0 Li :! 1ll1! .TEMPERATURE RATING Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature2 Bulb Color U o or Ordinary 135 °F (57 0C) 100 °F (38 °C) Orange Ordinary 155 °F (68 00) 100 °F (38 00) Red Intermediate 175 °F (79 00) 150 °F (65 °C) Yellow Intermediate 200 °F (93 00) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 00) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 18.06.21 Rev 18.1 *4 Page 4 of 6 MICROFAST® QUICK 4J II(IF1Gi l.l:II[.1..u.Lw RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) The Viking Microfast5 Quick Response KEY Finish Pendent Sprinkler VK302 AIX4— Escutcheon (if applicable) Maximum 175 PSI(12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals3 Part SIN style ______ K-Factor Length (Refer also to Design Criteria.) Number' NPT BSP U.S. metric' Inches mm cULus' VdS LPCB ((7 0., 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1ZB1Y,D2,C2X Al A1ZB1Y D1ZCIY D1W 19780 VK302 Pendent 1/2" -- 5.6 80.6 2-1/4 58 -- -- -- -- -- D3 21354 VK302 Pendent -- 15 mm 56 80.6 1 2-1/4 58 -- -- -- -- -- 03 INOTICE Product TIBelow Local VikingT.Jilrnj 06662B VK302 .Pendent 1 1/2" 15 mm 1 5.6 1 80.6 1 2-1/4 58 A1Z, B1Y, D2, C2X I -- -- -- -- 18021 VK302 I Pendent 1 1/2" 15mm 5.6 1 80.6 1 2-1/4 58 A1X,B1Y Al I A1X,B1Y I D1X,C1Y7 I D1W Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175°F 1 - Brass, Chrome, White W- Recessed with the Model F-i Adjustable Escutcheon only (79 °C), 200 °F (93 °C), 286 °F (141 °C) Polyester56, Black Polyes- X - Standard surface-mounted escutcheon or the B - 135 °F (57 °C), 155 °F (68 °C), 175 °F ter'-' Viking Micromatic5 Model E-1 Recessed Escutcheon (79 °C), and 200 °F (93 °C) 2 - ENT5 Y - Standard surface-mounted escutcheon or the C - 155 °F (68 °C), 175 °F (79 °C), and 3-Chrome Viking Microfast5 Model F-i Adjustable Escutcheon, or recessed with the Viking Micro- 200 °F (93 °C) matic5 Model E-1, E-2, or E-3 Recessed Escutcheon D - 155 °F (68 °C), 175 °F (79 °C), 200°F Z - Standard surface-mounted escutcheon or the (93 °C), 286 °F (141 °C) Viking Microfast5 Model F-i Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Vikings current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1 EC-certificate of constancy of performance 0832-CPR-50021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listinq Requirements: The Viking Microfast Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 18.06.21 Rev 18.1 Page 5of6 MICROFAST® QUICK ¼J I iiriG® lulIIEU'Lf. RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs®vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY The Viking Microfast5 Quick Response v Finish AIX 4— Escutcheon (it applicable) Pendent Sprinkler VK302 Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style (Refer also to Design Criteria.) NPT I BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2" 1 15 mm 5.6 80.6 2-1/4 58 A1Z, B1 Y, D2X, C2 L.11teE - Product B Limited VAvailability 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 I Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings x - Standard surface-mounted escutcheon or the 135°F (57 "C), 155 °F(68 °C), 175°F (79 °C), 200 °F Viking Micromatic Model F-i Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon 135 -F (57 °C), 155°F (68 °C), 175°F (79 °C), and 1-Brass, Chrome, White Polyester', V - Standard surface-mounted escutcheon or the 200 °F (93 °C) and Black Polyester4 Viking Microfast" Model F-i Adjustable Escutcheon, C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 or recessed with the Viking Micromatic Model F-i °F (141 "C) or E-2 Recessed Escutcheon D - 155°F (68 °C), 175°F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfast® Model F-i Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM ADDroval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. I I I Form No. F_033314 18.06.21 Rev 18.1 Page 6 of 6 MICROFAST® QUICK '%I I KJ F1 RESPONSE PENDENT SPRINKLER VK302 (K5.6) - The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com I Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) L. 2-1/2" (64 mm) maximum NPT 1 2-118"—*'I (54 mm) (45 Min. m (57 m) m) (51 mm) j(32 m) Installed with a standard Installed with a Microfast Note: At maximum, adapter 1/8" surface-mounted Model F-I Adjustable is exposed 1/2" (13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon 2-II8"... (54 mm) 4• I 1-3/4" (45 mm) Max. 1-1/8" T 1-1/8" (29 mm) 2" (29 mm) Min. (51mm) Mm. Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum Installed with a Installed with a Model Model E-I Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-I and E-2 Recessed Escutcheons I Form No. F_033314 18.06.21 Rev 18.1 Replaces Form No. F_033314 Rev 17.1 (Updated MED approval; added LPCB certificate number)