HomeMy WebLinkAbout6023 INNOVATION WAY; ; FPC2018-0110; PermitCi of PERMIT REPORT Carlsbad Print Date: 10/21/2021 Job Address: 6023 INNOVATION WAY, CARLSBAD, CA 92009-1741 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: DEV05109 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: BRESSI RANCH LOT 23 Description: LIFT -LOT 23 "BLDG A" SPRINKLER MONITORING Applied: 04/16/2018 Issued: 06/13/2018 Finaled Close Out: 02/07/2019 Inspector: Final Inspection: Permit No: FPC2018-0110 Status: Closed - Finaled Fire Alarm Applicant: FPContractor: CVA SECURITY CHULA VISTA ALARM INC JAMES RODRIGUEZ 6175 PROGRESSIVE AVE, # STE 400 6175 PROGRESSIVE DR, # STE 400 SAN DIEGO, CA 92154-6647-SAN DIEGO SAN DIEGO, CA 92154-6648 (619) 585-9111 (619) 585-9111 FEE AMOUNT FIRE Expedited Plan Review Per Hour - Office Hours $132.00 FIRE Sprinkler Monitoring $371.00 Total Fees: $503.00 Total Payments To Date: $503.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Hc'19-4-cmo Alt SPRINKLER MONITORING SYSTEM SUBMITTAL LIFT - LOT 23 6021 & 6023 INNOVATION WAY CARLSBAD, CA 92009 0 FUEGO ENGINEERING & DESIGN INC PREPARED FOR: CHULA VISTA ALARM INC P.O. BOX 212731 6175 PROGRESSIVE AVE. SUITE 400 CHULA VISTA CA, 91921 SAN DIEGO, CA 92154 CELL: (619)610.8637 PHONE: 619-585-9111 OFFICE: (619)796-3360 PROJECT: LIFT-LOT 23 6021 & 6023 INNOVATION WAY CARLSBAD, CA 92009 Model Number Description CSFM# MS-9200UDLS FIRE LITE FIRE CONTROL PANEL 7165-0075:0208 3G4010-CF DSC CELLULAR FIRE COMMUNICATOR 7300-1273:0161 SD355 FIRE LITE ADDRESSABLE SMOKE DETECTOR 7272-0075:0194 H355 FIRE LITE ADDRESSABLE HEAT DETECTOR 7270-0075:0195 302-AW-135 FIRE LITE WEATHER PROOF HEAT DETECTOE 7270-0021:0001 BG-12LX FIRE LITE ADDRESSABLE PULLSTATION 7150-0075:0184 MFF-301 FIRE LITE ADRESSABLE MINI- MONITOR MODULE 7300-0075:0185 MDF-300 FIRE LITE ADDRESSABLE DUAL MONITOR MODULE 7300-0075:0185 CRF-300 FIRE LITE REALY MODULE 7300-0075:0185 MR-101/C MULTI VOLTAGE AUXILIARY RELAY 7300-1004:0101 55U00672 FIRE DOCUMENT BOX N/A PS-12120 BATTERY 12VDC, 12 AMP N/A PS-1270 BATTERY 12VDC, 7 AMP N/A . FUEGO ENGINEERING & DESIGN INC PREPARED FOR: CHULA VISTA ALARM INC P.O. BOX 212731 6175 PROGRESSIVE AVE. SUITE 400 CHULA VISTA CA, 91921 SAN DIEGO, CA 92154 CELL: (619) 610-8637 PHONE: 619-585-9111 OFFICE: (619)796-3360 [I MS.9200UDLS(E) Rev 3 Intelligent Addressable FACP with Built-In Communicator General The Fire-Lite MS-9200UDLS Rev 3 with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This compact intelligent addressable control panel has an extensive list of powerful features. While the MS-9200UDLS Rev 3 may be used with an SLC configured in the CLIP (Classic Loop Interface Protocol) mode, it can also operate in LiteSpeedTM mode—Fire'Lite's latest polling technology—for a quicker device response time. LiteSpeed's patented technology polls 10 devices at a time. This improvement allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification cir- cuits in under 10 seconds. With Litespeed polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The MS-9200UDLS Rev 3's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, additional secondary ANN-BUS, and increased power for the resettable and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polar- ity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. It also allows remote and local programming of the control panel using the PS-Tools Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows® XP or greater, a compatible modem, and PS-Tools—the Fire'Lite Upload/Download software kit—may serve as a Service Termi- nal. This allows download of the entire program or upload of the entire program, history file, walktest data, current status and system voltages. The panel can also be programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus devices, AD355 (LiteSpeed), USB port, NAC circuit diagnostics, a new report has been added to the walk- test that lists untested devices, new device types added: audio telephone type code for ACC 25/50ZST, Photo Supervisory and auto-resettable Drill (non-latching). The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary tele- phone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9200UDLS is used in this document to refer to both the MS-9200UDLS and the MS-9200UDLS(E) FACPs (Fire Alarm Control Panels). DF-60601 Al • Al -60 Fure.LlTeeALarms by Honeywell Features Listed to UL standard 864, 9th edition. On-board DACT. Remote site or local USB port upload/download, using PS- Tools. Four (4) Style Y (Class B) NAC circuits, which can be con- verted to four (4) Style Z (Class A) circuits with optional ZNAC-92 converter module. (Up to 6.0 amps total NAC power when using optional XRM-24B.) Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules or LCD-80F, ANN-80 or Legacy ACS Annunciators. ANN-BUS for connection to following optional modules (cannot be used if ACS annunciators are used): - ANN-80(-W) Remote LCD Annunciator - ANN-I/O LED Driver - ANN-S/PG Printer Module - ANN-RLY Relay Module - ANN-LED Annunciator Module - ANN-RLED Annunciator Module alarms only - ROME Relay Option Module Enclosure ACS/TERM: - ACS Annunciators: Up to 32 Legacy ACM Series annun- ciators (ACM-16AT or ACM-32 series). Cannot be used if ANN-BUS devices are used. - Terminal-mode Annunciators: Up to 32 Legacy LCD-80F remote annunciators. DF-60601:A1 .12107/2010—Page 1of6 EIA-232 printer/PC interface (variable baud rate) on main circuit board, for use with optional UL-listed printer PRN-6F. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterflow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 rn), See installation manual for wire tables. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (CMF-300 or CMF-300-6). The four Class B NACs can be converted to four Class A NACs with optional ZNAC-92 converter module. Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum 24V0C system power output is shared among all NAC circuits and 24V0C special-application auxiliary power outputs. Total available output is 3.0 amps. Using the optional XRM-24B transformer increases 24VDC output to 6.0 amps. PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Three Form-C relay outputs (two programmable) 99 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package (order programming kit PS-Tools, separately). Upload/ download system programming locally to the MS- 9200UDLS Rev 3 in less than one minute. USB upload/download programming with standard Male-A to Male-B cable. User Interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Alarm Silenced (yellow) System Trouble (yellow) Maintenance/Presignal (yellow) Disabled (yellow) Battery Fault (yellow) Ground Fault (yellow) KEYPAD CONTROLS Acknowledge/Step Alarm Silence Drill System Reset (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys Enter Product Line Information MS-9200UDLS: 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, sin- gle printed circuit board mounted on chassis, and cabinet. 120 VAC operation. MS-9200UDLSE: Same as MS-9200UDLS, except with 240 VAC operation. 4XTMF Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. ZNAC-92: Optional converter module which converts four (4) Style V (Class B) NAC circuits to four (4) Style Z (Class A) cir- cuits. PK-CD Programming software for Windows®-based PC com- puter (cable not included), available on www.firelite.com. DP-9692: Optional dress panel for MS-9200UDLS Rev 3. TR-CE: Optional trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB- 55F for mounting. BAT Series: Batteries, see data sheet DF-52397. XRM-24B(E): Optional transformer. Increases system power output to 6.0 amps. Use XRM-24BE with MS-9200UDLS Rev 3(E). PRTIPK-CABLE: Cable printer/personal computer interface cable; required for printer or for local upload/download pro- gramming and updating panel firmware. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT-2I2UD, IPDACT Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT tele- phone output ports for internet communications over customer provided ethernet internet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. (See data sheet DF-60407 or DF-52424 for more information.) S S Page 2of6—DF-60601:A1. 12/07/2010 S S IPBRKT: Mounting kit for IPDACT-212U0 in common enclo- sure. IPSPLT: V-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. COMPATIBLE ANNUNCIATORS ANN-80(-W): LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD dis- play. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with red enclo- sure (see DF-60241). ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241). ANN-RLY: Relay Module, which can be mounted inside the cabinet, provides 10 programmable Form-C relays. (See DF- 52431.) ROME: Relay Option Module Enclosure. Provides one ANN- RLY Relay Module already installed. The ROME Series pro- vides mounting space for one additional Relay Module or one addressable Multi-module. (See Installation Sheet PN 53530.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ACM-8RF: Relay module provides 8 Form-C 5.0 amp relays. ACS-LED Zone Series: LED-type fire annunciators capable of providing up to 99 software zones of annunciation. Available in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. LCD-80F (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more Information on Compatible Annunciators for use with the MS-9200UDLS Rev 3, see the following data sheets (doc- ument numbers) ACM-8RF (DF-51555), ACS/ACMSeries (DF- 52378), LDM Series (DF-51384), LCD-80F (DF-52185). LITESPEED COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. 5D355: Addressable low-profile photoelectric smoke detector. 5D355T: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. 5D355R: Addressable remote test capable detector for use with D355PL or DNR(W) duct smoke detector housings. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fixed high-temperature detector that activates at 190F/88C. AD355(A): Low-profile, intelligent, "Adapt" multi-sensor detec- tor (B35OLP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitivity test. D355PL: Innovair Flex low-flow non-relay duct-detector hous- ing. SD355R included. DNRW: Innovair Flex low-flow non-relay duct-detector hous- ing, with NEMA-4 rating. Watertight. (Order 5D355R sepa- rately.) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0° (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style 0 option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. OF-60601:AI • 12/07/2010 - Page 3d 6 CMF-300: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0 (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0 (10.16 cm.) box, surface mount using the SM13500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. 1300: Fault Isolator Module. This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 opera- tion). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. MMF-302-6: Six-zone interface module for compatible conven- tional two-wire detectors. Mount one or two modules in a BB- 2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a 1313-617. CRF-300-6: Six Form-C relay control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a 1313-617. NOTE: 1) For more information on Compatible Addressable Devices for use with the MS-9200UDLS Rev 3, see the following data sheets (document numbers): AD355 (DF-52324), BG-12LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-60379), CMF/CRF Series (DF-52130), CP355 (DF-52383), D355PL (DF- 52398), H355 Series (DF-52385), 1300 (DF-52389), MMF-300 SerieslMDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF- 302-6 (DF-52356), SD355/S0355T (DF-52384). 2) Legacy 300 Series detection devices such as the CP300/CP350, SD300(T)/ SD350(T) and older modules such as the M300, M301, M302, C304, and BG-IOLX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard LiteSpeed protocol. Please consult factory for further information on previous 300 Series devices. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel manual for wiring details. S Page 4ot6—DF-60601:A1 • 12/07/2010 DF60601:AI 12/07/2010—Page 50f6 S SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits . 1 Addressable device capacity..........................................198 Programmable software zones.........................................99 ACS Annunciators ............................................................32 ANN-bus devices..............................................................16 Electrl~la €pecf ications AC Power: MS-9200 Rev 3:120 VAC, 60 Hz, 3.0 amps. MS-9200UDLS Rev 3E: 240 VAC, 5 0 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery charger capacity: 7 AH - 18 AH batteries. Up to two 18 Ah batteries can be housed in the FACP cabinet. Larger batteries require an external battery charger such as the CHG- 75 or CHG-120, and a separate battery cabinet such as the BB-26 or NFS-LBB. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style V (Class B) for a total of four Style V (Class B) or with an optional ZNAC-92 module con- verts to four Style Z (Class A) NACs. Maximum signaling cur- rent per circuit: 2.5 amps. End-of-Line Resistor: 4.71K ohm, 1/2 watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to panel documentation and Fire-Lite Device Compatibility Docu- ment for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps © 30 VAC (resistive). Form-C relays. Special Application Non-resettabie Power (24 VDC Nomi- nal): Jumper selectable (JP4) for conversion to resettable power output. Up to 1.0 amp total DC current available from each output. Power-limited. Special Application Resettable Power (24 VDC nominal): Jumper selectable (JP6) for conversion to non-resettable power. Up to 1.0 amp total DC current available. Refer to the Fire-Lite Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 300 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Unless used with Teldat VISORALARM, requires dedicated business telephone number with a mini- mum of 5 volts DC (off-hook voltage). Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12° (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65° (42.29 cm.) wide x 5.20° (13.34 cm.) deep. Trim Ring (IR-CE): 22.00° (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 270C/60 - 80°F. NFPA Standards The MS-9200UDLS Rev 3 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow, and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be con- nected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler Supervisory). - CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). - OT, PSDN (Other Technologies, Packet-switched Data Network) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9200UDLS Rev 3 control panel. In some cases, certain mod- ules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S624 FM approved CSFM: 7165-0075:0208 MEA: 120-06-E For ULC-listed version, see DF-60599. FireLite® Alarms® is a registered trademark of Honeywell International Inc. Wheelock® is a registered trademark of and ExcederrM is a trademark of Cooper Notification. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. This document is not intended to be used for installation purposes. I so ooi We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MMIFRC11fflNC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.flrelite.com Page 6of6—DF-60601:A1 • 12/07/2010 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION 7mi OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7165-0075:0208 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev©Honeywell.com DESIGN: Models MS-9200U0 and MS-9200UDLS a ressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *MS..9200UDLS panel also suitable for high-rise application for use with Model ECC-50/100 emergency voice evacuation panel (CSFM # 6911-0075:0226). 5 This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 11-12-13gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed f\ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other is Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Dec 0 From Tyco Security Products 3G technology from DSC! Features That Make a Difference: Uses HSPA (3G) network for high-speed, reliable and low- cost communications to an lP receiver Automatically switches to 2G (EDGE/GPRS) if 3G service is not available Compatible with control panels that communicate using Contact ID or SIA (300 baud) formats Full event reporting 4 on-board inputs with NC, NO or SEOL supervision 4 on-board outputs (open collector) Activation and initialization via automated telephone activation system (VRU), web-user or mobile interface provided by C24 Communications View communicator status directly from your mobile phone to support on-site or remote troubleshooting Compatible with Sur-Gard® System I-IP/lI/lll/IV/5 monitoring station receivers Includes UL listed power supply, transformer and 7 Ah rechargeable battery UL 864 listed S • CSFM listed The 3G401OCF connects the alarm control panel to the Cellular network and reports alarm signals directly to a monitoring station receiver (Sur-Gard System l-IP/11/110V/5). The 3G401OCF uses the Cellular network to ensure low-cost, high-speed and reliable alarm communications and is compatible with control panels that communicate using the Contact ID or SIA (300 baud) format. The 3G401OCF is compliant with the latest requirements for Communications Methods as per UL864 and NFPA72 2010 and 2013 Editions. It can be used in Fire Monitoring applications as a single communications technology, in which case any failure of the communications path shall be annunciated at the supervising station within 5 minutes (NFPA72 2010) or 1 hour (NFPA72 2013) of the failure, or it can be used as part of a multiple communications technologies (for example in conjunction with a DACT). When used as a back-up provision shall be made to monitor the integrity of each communication path and failure of any communications path shall be annunciated at the supervising station and at the protected premises within not more than 24 hours of the failure. How it Works The 3G401OCF can be used as either a Sole Communicator or as a Backup Communicator. When being used as a Sole Communicator the 3G401OCF will replace the phone line connection on the panel and as soon as it detects that an alarm needs to be transmitted it will send the alarm across the Cellular network immediately. When being used as a backup the communicator assesses the connection to the PSTN phone line, and only in the event of a phone line failure will it send all alarm traffic across the Cellular network to the monitoring station. In instances where the control panel does not support Contact ID or SIA (300 baud), the 3G401OCF has inputs pre-set to transmit fire alarm, fire supervisory or system trouble. Alarm signals are transmitted directly without the need of a clearinghouse to the IF linecard of the monitoring station receiver (Sur-Gard System l-IP,ll/lll/IV/5). Dec From Tyco Security Products S Activating & Initializing the Unit Activating and initializing the 3G401 OCF can be done using the automated telephone activation system ('JRU), mobile interlace or web-user interlace provided by C24 Communications. No special tools are required. Mobile Site for Easy Installation and Comprehensive Maintenance C24 Communications mobile site (m.connect24.com) makes the installation a simple process and offers intuitive trouble-shooting features, cutting down on time and cost allocated to maintenance. UL Listing The 3G4011 OCF is UL listed under File S4019, Usting guide UO)O<, as a sole or backup communicator for Commercial Fire monitoring installations. When used as a sole communicator under NFPA72 2010 guidelines the 3G401 OCF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window. When used as a sole communicator under NFPA72 2013 guidelines the 3G401 OCF will send its heartbeat once every 5 minutes to monitor connectivity with the supervising station within the 1 hour window. When used as a backup communicator the 3G401 OCF will monitor the other communication method (DACT) and send a daily test transmission to the supervising station. CSFM Listing The 3G401 OCF has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. Ordering Information: 3G4O1 OCF-USA .......... Universal Wireless Commercial Fire Alarm Communicator (U.S. Model/SIM Card Included) Rate Plan Cost-effective rate plans have been negotiated and are available through authorized master resellers. Contact your monitoring station or visit www.connect24.com to find a master reseller. When used as a sole communicator, the 3G401 OCF requires use of the 4MB (NFPA72 2010) or 500kB (NFPA72 2013) rate plans to support the supervision requirements. Specifications Dimensions ................................................ 11-1/2 x 10" x3° (290 mm x 254 mm x 75 mm) Input Voltage.............................................................120 VAC Current Draw ..............................................200 mA (standby) 400 mA (transmitting) Operating Environment ................32° to 120° F (00 to 49° C) Weight ........................ ................................... 12.8 lbs (5.8 kg) Optional Acessories Model Description GS-1 5ANT 15 ft extension antenna (internal use) GS-25ANT 25 ft extension antenna (internal/external use) GS-50ANT 50 ft extension antenna (internal/external use) S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION MIW4~ OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1273:0161 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Digital Security ControIs95 Bridgeland Ave, Toronto, Ontario M6A 1Y7 Canada Contact: Dan Nita (905) 760-3000 Fax (905) 760-3020 I dnita@tycoint.com DESIGN: Model 3G4010CF RF Communicator (GSM-GPRS/3G) signaling device. It is intended for use as a standalone communication technology (standalone unit). It may also be used as a backup communication technology in conjunction with a DACT. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 V, 50/60 Hz, 0.3 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as communicator signaling device for use with a separately listed fire alarm control unit. Refer to listee's Installation Instruction Manual for details. Q 06-03-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division °.- SD355(A)5 SD355T(A), SD355R(A) Flre.LlTeeAtarms Addressable Photoelectric Smoke Detectors by Honeywell I =1301 General The S0355(A) and SD355T(A) addressable, low-profile plug- in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's Address- able Fire Alarm Control Panels (FACPs). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (570C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annun- ciator capability is available as an optional accessory (PIN RA100Z(A)). The SD355R is a remote test capable detector for use with D355PL or DNR(W) duct smoke detector hous- ings. Features SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. SD355 with B35OLP base SD355T with B35OLP base Applications Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white LEXAN®. 5D355(T) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation 5D355(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0° (10.16 cm) square box with plaster ring. 4.0° (10.16 cm) octagonal box. 3.5° (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps" or branches are permitted for Style 4 (Class B) wiring. SD355R mounts in a 0355PL or DNR(W) duct detector housing. Direct Decade entry of address: 01 - 99 with MS-9200 series, and 01 - 159 with MS-9600 series. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-In tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 ml sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5° (8.89 cm) or 4.0° (10.16 cm) octagonal box, or 4.0° (10.16 cm) square electrical box (using a plaster ring — included). Other system features: Fully coated circuit boards and superior RFltransient pro- tection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA100Z). dt-52384:b.3/12/1O—Page 1 of 2 Operation Each S0355/T/R uses one of 99 possible addresses on the MS-9200 series and up to 318 (159 on each loop) on the MS- 9600 series Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The SD355/T/R addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar chamber, the SD355/T/R is approximately two times more responsive than most photo- electric sensors. This makes it a more stable detector. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-9200 series or MS-9600 series addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-9200 series or MS- 9600 series for record keeping. Specification Voltage range: 15-32 VDC (peak). Standby current: 300 pA @ 24 VDC. LED current: 6.5 mA © 24 VDC (latched "ON"). Air velocity: 4,000 ft/mm. (20 rn/sec.) maximum. Diameter: 6.1" (15.5 cm) installed in B350LP base. Height: 2.1" (5.33 cm) installed in B350LP base. Weight: 3.6 oz. (102 g). Operating temperature range: for SD355(A): 0°C to 49°C (32°F to 120°F); for SD355T(A): 0°C to 38°C (32°F to 100°F). SD355R(A): installed in a DNR(W) -20°C to 70°C (-4°F to 158°F). Temperature: 0°C - 49°C (32'F - 120°F). Relative humidity: 10% - 93%, non-condensing. Listings Listings and approvals below apply to the SD355(A) and 5D355T(A) detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed, file S1059. ULC Listed, file S1059. CSFM approved: file 7272-0075:194. MEA approved: file 243-02-E. FM approved. Product Line Information NOTE: "A" suffix indicates ULC-Listed mode!. SD355: Adressable photoelectric detector; B35OLP base included. SD355A: Sames as SD355 with ULC Listing (B35OLPA base included). SD355T: Same as SD355 but with thermal element; B35OLP base included. SD355TA: Same as S0355T with ULC Listing (13350LPA base included). SD355R: Remote test capable addressable photoelectric detector for use with a D355PL or DNR(W) duct detector hous- ing. B350LP(A): Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0° (10.16 cm) square box with or without plaster ring, 4.0° (10.16 cm) octagonal box, 3.5° (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5° (3.81 cm). B224RB(A): Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0° (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5° (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5° (3.81 cm). B224B1(A): Plug-in System Sensor Isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). Diameter. 6.2° (15.75 cm). Mounting: 4.0° (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5° (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5° (3.81 cm). B200SR: Sounder base capable of producing temporal-3 or steady sound output. ACCESSORIES: RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B35OLP(A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501 (A) base only. RMK400: Recessed mounting kit. For use with 850 1(A) base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR20: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. T55-127-010:Detector removal tool without pole. BCK-200B: Black detector covers, box of 10. WCK-200B: White detector covers, box of 10. S S FlashScan® registered trademark of Honeywell International Inc. Bay- blend® Is a registered trademark of Bayer Corporation. 02010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document Is not Intended to be used for Installation purposes. We try to keep our product Information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. IMINESUNI a MANUEZ1U1111IN QUALITY SYSTEMS All specifications are subject to change without notice. For more Information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.flreiite.com Page 2 of 2- df-52384:b • 3/12/10 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0194 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Viadim ireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kirey oneywell.com DESIGN: Models 5D350, SD350T, SD355, 5D355R*, 5D355T and AD355 photoelectric type smoke detectors. Model 5D350T and 5D355T has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC - INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. All units are suitable for open areas and inside duct installations with air velocities between 0-4,000 FPM. Models 5D355 and 5D355R* are also approved for installations inside Fire-Lite Duct Housing D355PL (CSFM Listing No. 3242-0075:221) and System Sensor Duct Housing DNRW (CSFM Listing No. 3242-1653:210). NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev. 01-11-2010fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division df-52385:A • E-710 S H355(A) Series Intelligent Addressable Thermal Detectors (a RreLITeALarms by Honeywell Addressable Devices 1-'t1t1 S The Fire.Lite Alarms H355 Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors are designed to provide open-area protection and are intended for use with the Flre.Lite's addresable Fire Alarm Control Panels (FACPs). The H355(A) and H355R(A) sensors provide fixed tempera- ture alarm detection at 135°F (57°C). The H355R(A) sensor also responds to rate-of-rise conditions of greater than 15°F (8.3°C) per minute. The H355HT(A) is a fixed high-tempera- ture detector that activates at 190°F (880C). These thermal detectors provide cost effective, addressable property protec- tion in a variety of applications. Two LEDs on each sensor light to provide a local, visible sen- sor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z). Features SLC loop: Two-wire SLC loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry of address: 01 - 159 with MS-9600, 01 —99 with MS-9200UD. Architecture: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type identifica- tion. Built-in tamper resistant feature. Built-in functional test switch activated by external magnet. Operation: Factory preset at 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate-of-rise triggers at 15°F (8.3°C) per minute for the H355R(A). 360°-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Visible LEDs "blink" every time the unit is addressed. Mechanicals: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and main- tenance. Separate base allows interchange of photoelectric, ionlza- lion and thermal sensors. Other system features: Remote test feature from the panel. Walk test with address display. Low standby current. H355 with B35OLP base 94-5V plastic flammability rating. Options: Remote LED output connection to optional RA400Z remote LED annunciator. Recessed (RMK400) or surface (SMK400E) base mount- ing kits. Installation H355(A) Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Mount base (all base types) on box that is at least 1.50 (3.81 cm) deep. Suitable boxes include: 4.00 (10.16 cm) square box. 3.5° (8.89 cm) or 4.0° (10.16 cm) octagonal box. Single-gang box (except relay or isolator base). NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7-taps" or branches are permitted for Style 4 (Class "B") wiring only. Applications Use thermal detectors for protection of property. Construction These detectors are constructed of off-white Bayblend®. The F$355(A) Series plug-in intelligent thermal detectors are designed to commercial standards and offer an attractive appearance. Operation Each H355(A) Series detector uses one of 159 (MS-9600) or 99 (MS-9200UD) possible addresses on a control panel SLC loop. it responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its elec- tronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The H355(A) Series offers features and performance that repre- sent the latest in thermal detector technology. df-52385:A • 12117/08 - Page 1 of 2 Specifations Diameter: 6.1' (15.5 cm) installed in B35OLP(A). Height: 2.1 (5.33 cm). Weight: 4.8 oz. (137 g). Installation temperature: -4°F to 100°F (-20°C to 38°C). Humidity range: 10% to 93% relative humidity (noncon- densing). LED current: 6.5 mA @ 24 VDC. Mounting: B35OLP(A) flanged base, included Fixed-temperature setpolnt: 135°F (57°C) for the H355(A) and H355R(A); 190°F (88°C) for the H355HT(A). Rate-of-rise detection: responds to greater than 15°F (8.3°C) per minute. Listings and Approvals Listings and approvals below apply to the H355(A) Series detectors. in some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. MEA approved: file 387-02-E UL Listed, file S2517 ULC Listed (models H355A, H355RA, H355HTA) CSFM approved: file 7270-0075:195 FM approved Product Line Information NOTE: A" suffix indicates ULC-Listed model. H355: intelligent thermal sensor; B35OLP base included. H355A: Same as H355 but with ULC Listing (13350LPA base included). H355R: Same as H355 with rate-of-rise feature; B35OLP base included. H355RA: Same as H355R but with ULC Listing (13350LPA base included). H355HT: intelligent fixed high-temperature thermal detector; B350LP base included. H355HTA: Same as H355HT but with ULC Listing (13350LPA base included). B350LP(A): Plug-In detector base (included). Dimensions: 6.1° (15.5 cm). Mounting: 4.0° (10.16 cm) square box with or without plaster ring, 4.0° (10.16 cm) octagonal box, 3.5° (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB(A): Plug-In System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224Bl(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DF-52389). Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0° (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501 BH-2(A): Plug-in System Sensor standard sounder base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting boxes have a minimum depth of 1.5" (3.81 cm). 6501 BHT-2(A): Plug-in System Sensor temporal tone sounder base. Voltage range: 15 to 32 VDC peak. _....p Standby current: 300 pA @ 24 VOC (one communication every five seconds with LED blink enabled). fl ACCESSORIES: RA400Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B35OLP(A) bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with B501 (A) base only. RMK400: Recessed mounting kit. For use with B501 (A) base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. Fire-Lite® Alarms Is a registered trademark of Honeywell International Inc. Bayblend® is a registered trademark of Bayer Corporation. 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document Is not Intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. -_ We cannot cover all specific applications or anticipate all requirements. INIFIRINC & MfNIMtURINO All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2- di-52385:A • 12/17/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL S FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0075:0195 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyev©Honeywell.com DESIGN: Models H350, H355, and H355HT fixed temperature heat detectors. Models H350R and dei ate-of-rise with fixed temperature heat detectors. Refer to listee's data sheet for product description and operational considerations. RATING: H350, H355, and H355HT 135° F fixed temperature H350R and H355R 15° F rate-of-rise H355HT 190° F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. NOTE: Rev. 05-06-05JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division df -50673: Rev • F-850 302 Series 8FIM-LITer ALarms Rate-Anticipation Heat Detectors by Honeywell Conventional Initiating Devices General The Thermotech 302 Series rate-anticipation heat detectors operate within a controlled range of two to three degrees of their set points, regardless of the speed or rate of temperature rise. These detectors are available in either 135°F (57.2°C) or 194°F (90°C) ratings. The 302 Series are normally-open devices designed espe- cially for fire detection and alarm systems. Features Immediate response. The 302 Series activate whenever ambient air temperature reaches a detector's setting, elimi- nating the thermal time lag inherent in conventional heat detectors. Eliminates false alarms. The 302 Series do not respond to momentary temperature fluctuations below the selected temperature. Universal application. The 302 Series can be used in all areas for any type of occupancy. Self-restoring. Hermetically sealed. Shock resistant, corrosion resistant, and tamper-proof. Principles Of Operation . The 302 Series rate-anticipation heat detectors respond and activate the fire alarm immediately whenever the ambient tem- perature reaches the preset temperature setting. Under rapid heat rise conditions, the rate-anticipation feature enables the detector to respond one to three degrees ahead of the setting. At the same time, however, it does not respond to momentary temperature fluctuations below the selected protection level, thus eliminating false alarms. When temperature drops back down below the protection level, the detector automatically resets itself. Dimensions (Model 302) Total overall length: 4-1/8" (10.48 cm). Base diameter: 2° (5.08 cm). Electrical Ratings 6-125VDC 5amps 6-25V0C lamp 125VDC 0.5 amp Application Information 302 Series detector have a smooth ceiling UL rating of 50' x 50' (15.24 x 15.24 meters) and are the only type of heat detec- tors having such a rating on both fixed temperature and rate anticipation. lVIpho1.9 Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S539 (302-AW-135/-194; 302-ET-135/-194; 302-135-194) FM Approved: (302-AW-135/-1 94; 302-ET-135/-194; 302-1351-194) CSFM: 7270-0021:001 1271 dlal.tll FINE SILVER CONTACT POINTS EXPANSION STRUTS HIGH EXPANSION SENSING SHELL 0.040 ANODIZED A.UMINUM HEAT ANTICIPATION CONTROL SLEEVE SET-TING SCREW DEVCON HERMETIC SEAL Cut-Away View dt-50673:Rev • 02/03/09 - Page 1 of 2 Thermotech Model 302 Series Rate-Anticipation Heat Detectors Model Number Description Refer To 302-135 135°F Interior Vertical Mounting Note 1 below 302-194 194°F Interior Vertical Mounting 302-AW-135 135°F All-Weather Vertical Mounting Note 2 below 302-AW-194 194°F All-Weather Vertical Mounting 302-ET-135 135°F All-Weather Vertical Mounting Note 3 below 302-ET-194 194°F All-Weather Vertical Mounting 302-EPM-135 135°F Explosion Proof Mounting Note 4 below 302-EPM-194 194°F Explosion Proof Mounting AP-P Decorative white plastic adaptor plate for mounting 302 and 302-AW to 4° outlet box. NOTE 1: For interior mounting in any atmosphere that is compatible with terminal-screw-type connections. UL rating 50 x 50(15.24 x 15.24 meters). NOTE 2: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox when the all-weather leads are properly spliced to 'THW" or equivalent type wire. NOTE 3: Hermetically sealed for moisture-proof or dust-proof installations. Requires no special backbox. Has plastic hexagonal wrench grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover, or any outlet box. NOTE 4: Explosion-proof for installation in hazardous locations. Has hexagonal wrench-grip bushing with 1/2" (1.27 cm) conduit threads for attachment to threaded hub cover of Series JL fixture fitting as manufactured by Killark Electric Co., or equal. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. This document Is not Intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. 1l?*lNI & MANlfMURINt All specifications are subject to change without notice. QUALITY SYSTEMS Made ln the U.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firellte.com Page 2 of 2— df-50673:Aev • 02/03/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0021:0001 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Thermotech lnc.,2900 North 1000 West, Ogden, UT 84414 Contact: A. Mark Headley (801) 782-2233 F (801) 782-1746 Email: therrnotechinc@hotm . co DESIGN: Models 302, 302H, 302AW, El and 302EPM heat detectors. Units are open circuit, 1350 F, 1940 F fixed temperature and rate-of-rise type heat detectors. Models 302 and 302-H are for indoor use. Models 302-El or 302-AW are for all weather use. Model 302-EPM is suitable for use in Class I, Groups C and D and Class II, Groups E, F and G hazardous locations. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6-125 VAC or VDC, 125 VDC 1350 F, 1940 F fixed temperature and rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models 302, 302-ET and 302-AW are for intended for vertical mount and Models 302-H is intended for horizontal mount only. MARKING: Listee's name, model number, electrical and temperature rating and UL label. APPROVAL: Listed as fixed temperature and rate of rise type heat detectors for use with separately listed compatible fire alarm control units. Rev. 05-01-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (a Fire uTeALarms by Honeywell ----- BG-12LX . Addressable Manual Pull Station DF-52013:C. E-100 S S General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs). Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Builtin bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[131); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VOC. Maximum SIC loop voltage: 28.0 VDC. Maximum SIC loop current: 230 VA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is "T= I usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600 Series, 1 - 99and MS-9200UDLS, 1 —50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with dearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-lU or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4° (10.16 cm) square electrical box, and shall be installed within DF.52013:C "09/02/2009—Page 1 0t2 the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-110: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S711 MEA: 67-02-E CSFM: 7150-0075:184 FM Approved Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. S FlreLite Is a registered trademark of Honeywell International Inc. 02009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document Is strictly prohibited. This document Is not intended to be used for Installation purposes. Iso 9001 We try to keep our product Information up-to-date and accurate. . . We cannot cover all specific applications or anticipate all requirements. IfllNfl $MNflIFMTII1XC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more Information, contact Fire. Ute Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.flrelite.com Page 2 of 2— DF-52013:C • 09/022009 S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS lNC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 Email: vladimir.kireyevHoneywell.com DESIGN: Models BG-12, BG-125, BG-12NC, BG-12W, BG-I2LW, BG-12WP, BG-I2LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-12SP, BG-12LR, BG-12LRA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-12L0B, BG-12LPS, BG-12LPSP, BG-12SL, UT-PSi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed productdescription and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-1 2WP, BG-1 2W, BG-1 2LW and BG-1 2LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAViD CASTILLO, Program Coordinator Fire Engineering Division df-52121:b• E-325 MMF-300(A) Series, MDF-300(A) 8 FlreuTeALarms Addressable Monitor Modules by Honeywell General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302). MMF-300 is a standard-sized module (typically mounts to a 4° [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. MMF-301 is a miniature monitor module (a mere 1.3" (3.302 cm) H x 2.75' (6.985 cm) W x 0.5° (1.270 cm) D) used to supervise a Class B (Style B) circuit of dry-contact input devices. Its compact design allows the MMF-301 to often be mounted in a single-gang box behind the device it monitors. MMF-302 is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. MDF-300 is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact Initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. MMF..300 Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each mod- ule is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Cir- cuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300 can be used to replace M300 modules in existing systems. MMF-300 APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class 017 =-Z" &CI•)72 t N $Ufl(.) NSOLOLNILSTtG 1 '1 01~ . - MMF-300 (Type H) A) initiating Device Circuit. A 471< ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300 OPERATION Each MMF-300 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-300 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Maximum operating current: 375 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301 Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. df-52121:b.11/13/08—Page lof4 Q1 I 14 ° i IADDRESS o 1 12 1 -' 2 12 11 0~. LOOP 1 5 57 8 76 I TENS ONES o L&j Q 0 -J -_J LU • -4 c I co The MMF-301 Mini Monitor Module can be installed in a sin- gle-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mount- ing. The MMF-301 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. it provides a two-wire initiating device circuit for normally-open-contact fire alarm devices. The MMF-301 can be used to replace M301 modules in exist- ing systems. MMF-301 APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. MMF-301 OPERATION Each MMF-301 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). MMF-301 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum operating current: 375 VA. Maximum IDC wiring resistance: 1,500 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3° (3.302 cm) high x 2.75° (6.985 cm) wide x 0.65' (1.651 cm) deep. Wire length: 6 (15.24 cm) minimum. MMF.302 Interface Module LED latches steady to indicate alarm on command from control panel. The MMF-302 Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The MMF-302 can be used to replace M302 modules in existing systems. MMF-302 APPLICATIONS Use the MMF-302 to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. jiirj1IiF1.1J;T_t1L.Ai Each MMF-302 uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). MMF-302 SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Maximum operating current: 270 pA (LED flashing) EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% 1093% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF.300 Dual Monitor Module The MDF-300 Dual Monitor Module is intended for use in intel- ligent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel-controlled LED. NOTE: The MDF-300 provides two Class B (Style B) lOG circuits ONLY. Class A (Style 0) IOC circuits are NOT supported in any application. MDF-300 SPECIFICATIONS S Supports compatible two-wire smoke detectors. Normal operating voltage range: 15 to 32 VDC. Supervises IDC wiring and connection of ext , Maxlmum current draw: 6.4 mA (LED on). source. Maximum operating current: 750 pA (LED flashing). High noise (EMF/RFI) immunity. 100, Maximum IDC wiring resistance: 1,500 ohms. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series EOL resistance: 47K ohms. panels, 01 —99 on other compatible systems. Temperature range: 32° to 120°F (0° to 490C). LED flashes during normal operation. Humidity range: 10% to 93% (non-condensing). Page 2of4—df-52121:b. 11/13/08 Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125' (5.398 cm) deep. MDF..300 AUTOMATIC ADDRESSING The MDF-300 automatically assigns itself to two addressable points, starting with the original address. For example, if the MDF-300 is set to address '26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300 are 0, 2, 4, 6, or only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300, MMF-302, and MDF-300 modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The MMF-301 module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S3705 ("A" suffix models) FM Approved CSFM: 7300-0075-185 MEA: 72-01-E Product Line Information NOTE: "A" suffix indicates ULC Listed mode!. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. df-52121 :b • 11/13/08 - Page 3 of 4 Fire-Lite® and UteSpeed® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. MAUMMIUMIR All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4of4—df-52121:b. 11/13/08 df-60379:A1 • E-400 CRF-300(A) Relay Module (2) ii re• LiTeALarms by Honeywell Aidressa6ië1Di] The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTM is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settabte) will identity the module to the con- trol panel, so as to differentiate between a control module and a relay module. TC2 ,,..,_c, •I•t a CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on. Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 490C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25° (3.175 cm) deep. Mounts to a 4° (10.16 cm) square x 2.125° (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum Current Voltage Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (LJR=5ms) Coded 30 VDC 0.5 A Inductive (UR=2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A High noise immunity (EMF/RFI). • Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 —99 on MS-9200UDLS(A) and MS-9050U0(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction dt-60379:A1 • 08/04/09— Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA: 72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. LlteSpeed is a trademark and Fire-Lite® Alarms Is a registered trademark of Honeywell international Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. _______________ Iso 9001 we try to keep our product information up-to-date and accurate. _____________ 9330333=1 • ., We cannot cover all specific applications or anticipate all requirements. ______________ fNINEEIIN S MRMJFA11JIlJNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firellte.com Page 2012— df-60379:A1 • 08/04/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Vladimir Kireyev (203) 484-7161 Fax (203) 484-7309 E ii: vIadimir.kireyevHon 41; DESIGN: M e s MDF-300, MMF-301 M F-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: S *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 5 Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division -'-, .------.----. AIR PRODUCTS AND CONTROLS in Control MR-100, 200 SERIES MULTI-VOLTAGE CONTROL RELAYS PRODUCT DESCRIPTION The MR Series Multivoltage Control Relays offer SPDT or DPDT I 0Amp resistive contacts which may be operated byone of four input control voltages. A single relay may be energized from a voltage source of 24VDC, 24VAC, I 2OVAC or 230VAC by wiring to appropriate input terminals. Each relay position contains.a red LED which indicates the relay coil is energized. Relays may be "snapped apart" from a standard 4 module assembly and used independently. These Devices areldeal for applications where local contacts are required for system status, remote contacts for control of electrical loads and general purpose switching.They are suitable for use with HVAC,Temperature Control, Fire Alarm, Security, Energy Management and Lighting Control Systems. _ FEATURES + Relays maybe energized from a voltage source of 18 to 35VDC orVAC, I 2OVAC or 230VAC + Each relay position contains a red LED, which illuminates when the coil is energzed.This provides a time saving device when checking an installed system - no metering is required Single, dual or triple relay modules may be "snapped apart" from standard 4-position master DC control inputs are polarized •• For continuous duty use at 24VAC, 24VDC, I 2OVAC, or 230VAC Available in dust resistant enclosures with LED viewing port(s) IC versions mounted in enclosures + /CIR versions with red covers for NYC and other uses . IT versions come complete with track mounting hardware which facilitates CSFM LISTED installation in standard cabinets + IJL recognized relays rated at 10,000,000 mechanical operations MEA ACCEPTED UL listed as Control UnitAccessory RECOGNIZED COMPONENT WIRING (TYPICAL FOR ONE MODULE POSITION) MR-101 SPOT CONTACT RESISTWE 7A3OVDC, 1G' 0 IS5VAC. 7A C 250WC NWCTWE 25P 1251250VAC (N.C4 33 NP 12512VAC (NO.) MR-201 OTOTNTACTS RESISTIVE: lAO 331/DC ISA C 1251/AC. 1A C 301/AC IIUCflVE .2SHP 1251301/AC (NC. .33 P 125250VAC(N.O.) S RELAY ENERGIZED LED --10- 0 0. NOTE: DCCOIL INPUT, IS - POLARIZED I= INPUT -00 0 CONTROL • I 'T 1 T VOLTAGES 24VAC C ktE1 ;24VDC ISIM - I) I •' EXD'Zl C. I20VACO2lmA -3._N H 2VAC lEnA -3. _12 LI Air Products and Controls is a Brand of Apollo America A 25 Corporate-Drive HALMA Auburn Hills,-.Ml 48326 (248) 332-3900 Phone GROUP (888) 332-2241 Toll free COMPANY (248) 332-8807 Fax www.ap-c.com Distributed PRODUCT SPECIFICATIONS 5 -- - -.-. ..... •(S( I II * .Acn flOCILA JJI1 Urn., I I rvw.,r MODEL MODULE CONFIGURATION MOUNTED MOUNTED COVER FILE FILE 1 73-'92-E FILE NUMBER: POSITIONS PER POSITION H X W X D H X W X 0 MATERIAL S3403 7300-1004 3.25" (82mm) MR-101/T 1 SPDT 2.125" (54mm) UOXX2 :106 1.50' (38mm) Grey MR-IOIIC 1 SPDT 5.125" (130mm) ABS-94V0 UOXX Vol. 14 ________ 3.125" (79mm) 2.50" (63mm) Plastic UOXX2 _______ :101 RedUOXX7 MR-IOI/C/R 1 SPDT ABS-94V0 Vol. 22 Plastic 3.25" (82mm) MR-104/T 4 SPDT 8.50" (215mm) UOXX2 :106 1.50" (38mm) Plated MR-1 04/C 4 SPDT 5.125" (130mm) 18ga UOXX 9.50" (241 mm) 2.50" (63mm) CRS UOXX2 Vol. 14 :101 RedUOXX7 MR-I 041C1R 4 SPDT 18ga CRS 3.25" (82mm) MR-2011T 1 DPDT 2.125" (54mm) UOXX2 :106 1.50" (38mm) Grey MR-20111C 1 DPDT 5.125" (130mm) ABS-94V0 UOXX Vol. 16 3.125" (79mm) 2.50" (63mm) Plastic UOXX2 ________ :101 RedUOXX7 ______ MR-201/C/R 1 DPDT ABS-94V0 Vol.22 Plastic 3.25" (82mm) MR-2041T 4 DPDT 8.5" (215mm) UOXX2 :106 1.50" (38mm) Plated MR-204/C 4 DPDT 5.125" (130mm) 18ga UOXX 9.50" 1241 mm) 2.50"(63mm) CRS UOXX2 UOXX7 Vol. 16 :101 4 DPDT :: Red MR-2041C1R ga ____________ __________ _____________ RS COIL VOLTAGE: MR-100: 24(18-35)VDC, 24(18-35)VAC, 120VAC, 230VAC MR-200: 24(18-35)VDC, 24VAC, 120VAC, 230VAC (Pull in voltage: 75% of nominal max. @ 25°C; Drop out voltage: 25% of nominal mm. @ 25°C) POLARIZED: DC input only ENERGIZED LED INDICATOR: One per module position CURRENT REQUIREMENT: Per module position: MR-100 Series = 48mA max! MR-200 Series = 69mA max CONTACT RATINGS: 7A © 28V0C /10A (NO:1/6HP, NC:1/8HP) © 120VAC / 7A © 230VAC CONTACT CONSTRUCTION: Dry Form "C" ENVIRONMENTAL: 32°F to 120°F (0°C to 49°C) @ 85% RH (@ 32°F), Non-condensing, Non-freezing WIRING: Solid or stranded; #14 to #22 AWG terminals /T VERSIONS: 3.5" wide, low profile plastic snap track provided with mounting screws IC VERSIONS: Backbox: 18ga CRS, plated with 1/2" conduit knockouts top and bottom *UO)0Kc0ntr01 Unit Accessories, System; 2Component; 7=Certified for Canada NOTICE: The information contained In this document is intended only as e summary and is subject to change without notice. The products described have specific lnstructlonalfinstalletion documentation, which covers various technical, approval, code, limitation and liability Information. Copies of this documentation along with any gen- eral product warning and limitation documents, which also contain Important Information, are provided with the product and are also available from Air Products and Controls Inc. The information contained In all of these documents should be considered before specifying or using the products. Any example applications shown are subject to the most current enforced local/national codas, standards, approvals, certifications, and/or the authority having jurisdiction. All of these resources, as well as the specific manufacturer of any shown or mentioned related equipment, should be consulted prior to any implementation. For further information or assistance concerning the products. contact Air Products and Controls Inc. Air Products and Controls Inc.reserves the right to change any and all documentation without notice. ©Air Products and Controls Inc. 2012 DS-RL-2 D120607 [1 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0. FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:0101 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America lnc.25 Corporate Dr. Auburn Hills, MI 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel@apollo-fire.com DESIGN: Models MR-101/C, *MRioi/cIR *MR101SsEIc *MRioiSsE/C/R MR-104/C, *MR104/C/R *MR104SSE/C, *MR104SSE/C/R, MR-201/C, MR-201/CrR, *MR201sSE/c *MR201SSE/CIR, MR-204/C, MR204/C/*R, *MR 204 SSE/C *MR204ssE/cIR PAM-1, PAM-2, PAM-3, PAM-4, PAM-SD, RlC-1, RIC-2, RIC-3, RlC-4, MRRlC301/*C, MR-RIC-301/C/R, MRRIC305*/C, * MR-RlC-305/C/R, MRRIC401*/C, *MRRIC401/C/R, MRRIC405*/C and *MRR1C405/CIR relay modules. *Models MR-lTM/C and MR-ITM/C/R relay modules (with test mode). Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm control units. Refer to manufacturers Installation Manual for details. 0 NOTE: 1. Formerly Air Products and Controls, Inc. *Rev. 04-03-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division p N (ç • p S S ACE-Il FIRE DOCUMENT BOX The FDB is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. Along with your fire alarm software you can store your test & inspection documents, service records, manuals & AS built drawings for the system. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. Standard Features: 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 1hdeep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard Wcat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information _ ISO 11 Mo mlvw RIJERED W NFPA ___ COMPANYWNWIEWH Made InIU.S.A. VW Z Space Age Electronics, Inc. 2013 ED0447 LT10505 Rev.0 1/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! IrSPACE AGE ELECTRONICS, INC. Specifications: The fire alarm documents box (FDB) shall be constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. P,op.tyInton1tIon Minim,,, Roqired Don,n,.nt,tim, (SIG-FUN) C.iliilcstiCnt Wid Appmvnis 16.1 Sy.l.m InnInhiJon Co,a-m h IEflbS,FN*adl.t 41..,nno...nodm.,,,a,.nat nnnlab, F- fib 16.5 Anhodly HnnIog J1.dion F0 F- Ilk_______________ in canoe. Fa .0kb.. .flb.q. Eq,IpnanI IntObmEiOi, ia-anafl.. _/ •,.0.n,,EO.0IlLpk UOin.ca*nd *c.MA0nbM Slkllsifl) W.I.lk0b. 6T10644 hIll Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SU00672 Fire Document Box RED '!AElectnl!Inc. \\ SSU00673 Custom screening with your Logo 800.486.1723 Toll Free EA0315 10 pack door legend sheet 508485.09 508.48547 This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0447 Lii 0505 Rev.0 2/2 S S Ip Terminals (mm) F3.4-1 F2 - Quick disconnect 0 16.35 tabs, 0.250" x 0.032" - Mate with AMP. INC FASTON '250" series I— 7.95 —I iIO8 5.95 (151) W. 3.86 (98) H: 3.70 (94) HT: 3.94 (100) Tolerances are +/- 0.04 In. (/- 1mm) and +/- 0.08 In. (1- 2mm) for height dimensions. All data subject to change without notice. Absorbent Glass Mat (AGM) technology for superior performance Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.0.T., I.A.T.A., F.A.A. and C.A.B. certified U.L. recognized under file number MH 20845 Nominal Voltage........................................................................12 volts (6 cells) Nominal Capacity 20-hr. (600mA to 10.50 volts) .......................................................12.0 AH 10-hr. (1.1A to 10.50 volts) ............................................................11.0 AN 5-hr. (2.1f\ to 10.20 volts) ............................................................10.5 AN 1-hr. (7.25A to 9.00 volts) .............................................................7.25 AN 15-mm. (21.5A to 9.00 volts)..............................................................5.38 AN Approximate Weight ...........................................................7.92 lbs. (3.59 kg) Energy Density (20-hr. rate) ...............................1.69 W-h/1n3 (103.41 W-h/1) Specific Energy (20-hr. rate) ..............................18.18 W-h/lb (40.08 W-h/kg) Internal Resistance (approx.) ......................................................20 milliohms Max Discharge Current (7 Mm.) ...............................................36.0 amperes Max Short-Duration Discharge Current (10 Sec.)................120.0 amperes Shelf Life (% of nominal capacity at 68°F (20°c)) 1 Month ......................................................................................................97% 3 Months.....................................................................................................91% 6 Months ....................................................................................................83% Operating Temperature Range Charge .. ........................................................... -4°F(-20°C)to 122°F(50°C) Discharge ....................................................... -40°F(-40°C)to 140°F(60°C) Case......................................................................................................ABS Plastic Power-Sonic Chargers ........................................... PSC-122000A, 122000A-C Discharge Characteristics MEN C-0 I!! 111100 m~iiii,§P"gpml"wm 111111101111 0MI M 1101 0 On IiiEIiIU•IIiRU Shelf Life & Storage S Standing Period (Months) 8.0 NENROMERE ssai a 60 ir•ui j•, RENNEWE 100 .2 (5 80 0 a 40 M Q. M 0 0 2 4 6 8 10 12 14 16 18 20 14.0 13.0 0 I.._ E (68°F) (32°F) 1: 20 15 10 30 Discharge Time vs. Discharge Current --- -- --- --- t'uuI NEE NEE so III I•• 1.2 2.4 6 12 24 36481 2 4 6 810 20 40 mm h ci Discharge Time 100 0 1 2 3 4 Years [Ambient remperature 20C (687) Float 2.25 Charging -2.30 Voltage V/Cell ii HH iii Life Characteristics in Stand-By Use Life Characteristics in Cyclic Use 120 100 80 0 a 60 U C .9 40 C 20 0 0 0.60 1.2 2.4 6.0 12 24 Discharge Current (A) Cycle Applications: Limit initial current to 3.6A. Charge until battery voltage (under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7 volts until current drops to under 120mA. Battery is fully charged under these conditions, and charger should be disconnected or switched to float" voltage. °F1oar or Stand-By" Service: Hold battery across constant voltage source of 13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Note: Due to the self-discharge characteristics of this type of battery, it is imperative that they be charged within 6 months of storage, otherwise permanent loss of capacity might occur as a result of sulfation. 1 .4 ::~ 1 1 77 Li Discharge Depth 100% IDiachalgu Depth 5011. I Discharge Depth 30 Discharge Current 0.2C (Final Voltage 1.7VICell) Charge Current: 0.IC I I I r- 3. Ambient Temperature: 20°C to 25°C (68°F to 77°F) I I I I I I 200 400 600 800 1000 1200 Number of Cycles Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for "C-Series downloads, such as product catalogs, material safety data sheets (MSDS), ISO Switch Mode Chargers" and "Transformer Type A and F Series". Please contact our certification, etc.. Technical department for advice if you have difficulty in locating suitable models. 02011. Power-Sonic Corporolion. All rights resereed. All tredemarllo we the property of their respectine owners. Mooa 1210F1 ..-.- 12W 7 0"W ] ' rnmin Fl - Quick disconnect tabs, 0.187" x 0.032"- Mate with AMP. INC. Ft F2 FASTON "187° series 32 -3.4-1 -OR - II1IIII1i I45 =K 6.35 F2 - Quick disconnect tabs, 0.250"x0.032" F63 _______ .=0.8 .=0.8 - Mate with AMP. INC FASTON '250" series Physical Dimensions: in (mm) I v HT ri n LJ H MODEL P3-1270 Fl == L 10 L:5.95(151) W:2.56(65) H:3.70(94) HT: 3.86(98) Tolerances are +1-0.04 in. (/- 1mm) and +1- 0.08 In. (+/-2mm) for height dimensions. All data subject to change without notice. Absorbent Glass Mat (AGM) technology for superior performance Valve regulated, spill proof construction allows safe operation in any position Power/volume ratio yielding unrivaled energy density Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.0.T., I.A.T.A., F.A.A. and C.A.B. certified U.L. recognized under file number MH 20845 Performance Specifications Nominal Voltage........................................................................12 volts (6 cells) Nominal Capacity 20-hr. (350mA to 10.50 volts) ........................................................7.00 AH 10-hr. (650mA to 10.50 volts) .......................................................6.50 AH 5-hr. (1.2A to 10.20 volts) ............................................................6.00 AH 1-hr. (4.5A to 9.00 volts) ..............................................................4.50 AH 15-mm. (14A to 9.00 volts) .................................................................3.50 AH Approximate Weight ...........................................................4.80 lbs. (2.18 kg) Energy Density (20-hr. rate) ................................1.49 W-h/in3 (90.95 W-h/1) Specific Energy (20-hr. rate) ..............................17.50 W-h/lb (38.58 W-h/kg) Internal Resistance (approx.) ......................................................23 milliohms Max Discharge Current (7 Mm.) ...............................................21.0 amperes Max Short-Duration Discharge Current (10 Sec.)..................70.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C)) 1 Month ......................................................................................................97% 3 Months.....................................................................................................91% 6 Months ....................................................................................................83% Operating Temperature Range Charge .. ........................................................... -4°F(-20°C)to 122°F(50°C) Discharge ....................................................... -40°F(-40°C)to 140°F(60°C) Case......................................................................................................ABS Plastic Power-Sonic Chargers ................................................ PSC-12800A, 12800A-C