Loading...
HomeMy WebLinkAbout6023 INNOVATION WAY; ; FPC2017-0334; PermitPERMIT REPORT (äty of Carlsbad Print Date: 10/21/2021 Job Address: 6023 INNOVATION WAY, CARLSBAD, CA 92009-1741 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: LIFT LOT #23 -SPRINKLER >100 -BUILDING A Permit No: FPC2017-0334 Status: Closed - Finaled Applied: 11/14/2017 Issued: 01/16/2018 Finaled Close Out: 08/12/2021 Inspector: Final Inspection: Applicant: FPContractor: INDUSTRIAL FIRE SPRINKLER CO INDUSTRIAL FIRE SPRINKLER CO INC STEVE SCOTT 3845IMPERlAL AVE 3845 IMPERIAL AVE SAN DIEGO, CA 92113-1702 SAN DIEGO, CA 92113-1702 (619) 266-6030 (619) 266-6030 x107 FEE AMOUNT FIRE NFPA 13 System > 100 heads (includes 1 riser) $832.00 Total Fees: $832.00 Total Payments To Date: $832.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Bressi Ranch Lot. # 23 Carlsbad, Ca. L_Ii I-•- FPC20170343 6021 Innovation WAY LIFT LOT#23- SPRINKLER >100- BUILDING B (J 12128/2017 FPC20I7-0343 Lift Lot # 23 CONTENTS Hydraulic Calculations Material Cut Sheets FPC20I7-0334 6023 Innovation WAY LIFT LOT #23 - SPRINKLER >100(478/2 RISERS)- BUILDING A & B 11/14/2017 FPC20I7-0334 3845 Imperial Ave., San Diego, CA., 92113 0 Phone (619) 266-6030 • Fax (619) 266-6035 draulic Calculations. for Project Name: Drawing3 Location: Drawing Name: Building B 1ST & 2nd Floor Piping Design Remote Area Number: I Remote Area Location: BLDG B LEV 1 Occupancy Classification: Ordinary Group I Commodity Classification: N/A Calculation Date: 12/19/2017 Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: 0.150g pm/ft2 1500.00ft2 (Actual 1514.94ft2) 127.50ft2 Upright 13 Type of System: WET Volume of Dry or PreAction System: N/A In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node I Type: Allowance at Source 250.00 at Node: 69 Type: Hydrant Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 511.88 @55.642 Water Supply Information: Name of Contractor: Address: Phone Number: Authority Having Jurisdiction: Notes: Automatic peaking results Name of designer: Left: 55.890 Right: N/A LAk@ M.E.P.CAD, Inc. AutoSPRINK® 12 02.0.61.0 1 12/19/201711:19:39AM Page 1 S Job Number: 1 - LIFT LOT #23 Report Description: Ordinary Group 1(1) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Hydrant 69 250.00 250.00 0 50.117 c Sprinkler 101 19.31 19.31 5.6 11.890 Sprinkler 104 19.31 19.31 . 5.6 11.896 Sprinkler 105 19.47 19.31 5.6 12.090 Sprinkler 106 19.52 19.31 5.6 12.149 Sprinkler 107 19.58 19.31 5.6 12.226 Sprinkler 108 19.58 19.31 5.6 12.226 Sprinkler 109 19.74 19.31 5.6 12.423 Sprinkler 110 19.80 19.31 5.6 12.505 Sprinkler 111 20.13 19.31 5.6 12.920 Sprinkler 112 20.53 19.31 5.6 13.445 Sprinkler 113 20.57 19.31 5.6 13.496 Sprinkler 114 20.63 19.31 5.6 13.577 Sprinkler 115 23.69 19.31 5.6 17.900 c Most Demanding Sprinkler Data , © M.E.P.CAD, Inc. Ig AutoSPRINK® 12 v12.0.61.0 12/19/2017 11:19:42AM Page 3 Hydraulic Graph Job Name: Drawing3 N 1.85 Remote Area Number: 1 Date: 12/19/2017 100 Water Supply - Summary Sheet go-:- Node: 1 80-- :Static Pressure 74.000 511.88 c 73.727 7O—- 511 .88c 55.642 4925.00 @ 56.000 CL 40 30 S stem demand curve 0_V.LLLLLLhhhhhhhh1 111111111 IllIllIll 111111111 liii liii 111111111 I 111111 I I I I I I I I 0950 1900 2850 3800 4750 5700 6650 7600 8550 9500 Flow - gpm L 1,© M.E.P.CAD, Inc. i( AutoSPRINK® 12 02.0.61.0 12/1912017 11:19:41AM Page 2 Job Name: Drawing3 Remote Area Number: fl Date: 12/19/2017 Pipe _Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total Friction(PO 101 13-6 5.6 1931 1 (See Notes) 0-8 120 11.890 Route I Sprinkler, T(5-0) 5-0 0.121948 0.289 5 12-10 19.31 1.0490 6-8 0.691 5 12-10 1% 8'-6 120 12.870 0024744 7 12'-10 1678 13800 8'-6 0.210 7 12-10 19.47 1/4 8'-6 120 . 13.081 Flow (q) from Route 3 8 12 36.25 0.102865'-10 1.3800 8'-6 0.874 ' 8 12'-10 2013 1Y (See Notes 911-1 120 13.955 Flow (q) from Route 9 4E(3'-O), T(6'-O) 0.232848 9 12'-10 56.38 1.3800 109-1 25.402 9 12'-10 11/4 (See Notes) 0'8 120 . 39.357 P0(6-0) 6-0 0.203995 0.289 10 12'-2 56.38 1.4180 6-8 1.360 10 12-2 3 8-8% 120 41.006 0.003173 ii 12'-2 56.38 3.3340 8'-8% 0.028 ii 12'-2 40.20 3 5'-3% 120 41.034 Flow (q) from Route 2 0.008588 12 12'-2 96.59 3.3340 0.046 12 12'-2 6048 3 (See Notes) 911% 120 41.079 Flow (q) from Route 5 1(15-0) 0.021114 13 12-2 157.07 3.3340 24'-111A 0.527 13 12-2 10481 3 (See. Notes 52 120 41.606 Flow (q) from Route 7 T(15-0) 0.054363 14 12-2 261.88 3.3340 20-2 1.095 14 12'-2 3 7'-i'/2 120 42.702 0.054363 3.081 15 5'.-O% 261.88 3.3340 7-1% 0.386 15 5'-O% 3 (See Notes) 11-1 120 46.169 CV(21 6) BV(13 51/2) 1 2 0060642 0.678 16 3'-6 261.88 32600 36 01/2 2.185 ©M.E.P.CAD, Inc. AutoSPRlNK®12vi2.0.61.O 1 12/19/2017 11:21:33AM Page 1 Job Name: Drawing3 Remote Area Number: n Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices E Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable are added directly to (Pf) and shown as a negative value. Fitting F (00) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow Actual ID Total (Foot) Friction(Pf) 16 3-6 3 (See Notes) 30 120 49.032 E(10-2%) 4BOR 10'-2% 0.055979 1.299 17 0'-6 261.88 3.3140 13'-2 0.738 17 0-6 6 (See Notes) 13'3 140 51.069 2E(23 1%) 46'-2% 0001787 1.951 18 40 7.26188 63400 0.106 18 4-0 6 (See Notes) 49500 101 72'7 150 53.126 3EE(3 11) T(16 10) 0005250 19 40 26188 0531 19 4-0 250.00 10 (See Notes) 51'0 150 53.657 Flow (q) from Route 14 2EE(5 8) 11'-4 0001713 -1.301 4 -11-0 51188 80360 624 0.107 4 -1-0 10 (See Notes) 8'-7% 140 52.463 E(36 1) BFP(3000) 36-1 0000539 -1.734 3 30 51188 104600 448 3024 3 3-0 8 (See Notes) 911 140 53.753 2E(31'-7/2) 63'-3 0001524 1.734 2 1 0 51188 84500 724 0110 2 -1-0 12 (See Notes) 60'0 150 55.598 Water Supply 0000746 1 1 0 51188 95320 60 0 0045 0.00 55.642 Hose Allowance At Source Total(Pt) Route 1 11 511.88 104 13-6 5.6 19.31 1 (See Notes) 0-8 120 11.896 •••••Route 2••••' Sprinkler, T(5 0) 5-0 0.122005 0.289 20 12'-10 19.31 1.0490 6-8 0 691 20 12'-10 2.53 1% 6-71/2 120 12.877 Flow (q) from Route 18 0040282 21 12'-10 2184 13800 6 0.267 21 12-10 19.52 1% (See Notes) 41% 120 13.143 Flow (q) from Route 4 T(6 0) 6-0 0 131260 24 12'-10 - 41.36 1.3800 10 1% 1.328 ,©M.E.PCAD, Inc. AutoSPRlNK®12v12.O.61.O 1 12/19/2017 11:21:33AM Page 2 Job Name: Drawing3 Remote Area Number: fl Date: 12/19/2017 Pipe Information - Node 1 Elev I (Foot) K-Factor Flow added this step Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) - Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 24 12'-10 20.53 1% (See Notes) 01 8 120 14.471 Flow (q) from Route 10 P0(6 0) 6-0 0 242406 0.289 25 12'-2 61 89 1 4180 6 8 1 616 25 12-2 21/2 5-8 120 16.376 0004698 28 12 2 4020 27050 5-8 0.027 28 12'-2 1v4 (See Notes) 0'8 120 16.403 P0(6-0) 6-0 0.109112 -0.289 30 12-10 40.20 1.4180 6-8 0.727 30 12'-10 1% (See Notes) 162'1 120 16.841 E(3'O) 3E(3'-O), C(6'-O), T(6'-O) 24-0 0.124545 31 12'-lO 40.20 1.3800 186-1 23.176 31 12'-10 1% (See Notes) 0'B 120 40.017 PO(6'-O) 6-0 0.109112 0.289 11 12'-2 - 40.20 1.4180 6-8 0.727 41.034 Total(Pt) Route 2:~l 105 13'-6 5.6 19.47 i (See Notes) 0'8 120 12.090 •••''Route 3••••• Sprinkler T(5'-O) 5-0 0.123840 0.289 7 12'-10 19.47 1.0490 5-8 0.702 13.081 Total(Pt) Route 3 106 13'-6 5.6 19.52 1 (See Notes) 0-8 120 12.149 •••• Route 4 Sprinkler, T(5 0) ,5-0 0 124405 0.289 21 12'-10 19.52 1.0490 6-8 0.705 13.143 Total(Pt) Route 4 107 13-6 5.6 19.58 1 (See Notes) 0'8 120 12.226 ••"•Route 5••••• Sprinkler 1(5-0) 5-0 0.125129 0.289 32 12-10 .. 19.58 1.0490 5'-8 0.709 32 12-10 1% 8'-6 120 13.224 0.000040 34 12-10 0.52 1.3800 8 -6 0.000 34 12-10 19.58 8'-6 120 13.224 Flow (q) from Route 6 0.034555 35 12-10 L . : 20.10 1.3800 I 8-6 0.294 ,©M.E.P.CAD, Inc. AutoSPRINK®12v12.0.61.O 1 12/19/2017 11:21:33AM Page 3 Job Name: Drawing3 Remote Area Number: 1 Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step q Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (N) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit psi Elev(Pe) Node 2 Elev 2 (Foot) . Total Flow Actual ID Total (Foot) Friction(P 35 12-10 19.80 11/4 8-6 120 13.518 Flow (q) from Route 8 0.122851 38 12'-10 39.91 1.3800 8-6 1.044 38 12-10 20.57 1% (See Notes) 81'1 120 14.562 Flow (q) from Route 11 2E(3'-O), T(6'-O) 12-0 0.265106 - -0.000 39 12-10 60.48 1.3800 93-1 24.680 39 12-10 11/4 (See Notes) 0'8 120 39.242 PO(6'-O) 6-0 0.232256 0.289 12 12-2 - 60.48 1.4180 6-8 1.548 41.079 Total(Pt) Route 5 108 13-6 5.6 19.58 1 (See Notes) 0-8 120 12.226 ••••• Route 6•"•• Sprinkler, T(5'-O) 5-0 0.125132 0.289 34 12-10 .: 19.58 1.0490 5-8 0.709 13.224 Total(Pt) Route 6 109 13-6 5.6 19.74 1 (See Notes) 0'-8 120 12.423 Route 7"" Sprinkler, T(5'-O) 5-0 0.126991 0.289 42 12'-10 - 19.74 1.0490 58 0.720 42 12-10 19.06 11/4 (See Notes) 4'l% 120 13.431 Flow (q) from Route 17 T(6'-O) 6-0 0.116596 43 12-10 - 38.80 1.3800 10'- 11/2 1.179 43 12-10 20.63 1% (See Notes) 0'.8 120 14.611 Flow (q) from Route 12 P0(6-0) 6-0 0.224853 0.289 47 12-2 59.43 1.4180 6'-8 1.499 47 12'-2 21.69 21/2 14-4 120 16.399 Flow (q) from Route 20 0.017215 48 12-2 81.12 2.7050 14-4 , 0.247 48 12-2 21/2 15-0 120 16.645 0.008178 51 12-2 54.25 2.7050 15-0 , 0.123 51 12-2 11,'4 (See Notes) 0'8 120 16.768 PO(60) 6-0 0.189957 -0.289 53 12-10 54.25 1.4180 , 6-8 1.266 , © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 1 12/19/2017 11:21:33AM Page 4 Job Name: Drawing3 Remote Area Number: S Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step q Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit PSI Elev(Pe) Node 2 Elev 2 (Foot) - Total Flow (Q' Actual ID Total (Foot) Friction(Pf) 53 12-10 1% (See Notes) 70'2 120 17.745 T(6'O) 2E(3-0) T(6 0) 18-0 0216824 55 1210 5425 13800 882 19118 55 12'-10 11/4 (See Notes) 51'10 120 36.864 2T(6'-O) 12'-0 0.061098 -0.000 57 12'-l0 27.36 1.3800 63'-10 3.900 57 12'-10 1% (See Notes) 0'8 120 40.763 P0(6'O) 6-0 0.053527 0.289 59 12'-2 27.36 1.4180 6-8 0.357 59 _____ 12'-2 ________ _____ 26.89 ________ 3 ______ 11,-1 120 41.409 Flow (q) from Route 15 0.002954 60 12'-2 ' 54.25 3.3340 11-1 0.033 60 12'-2 50.56 3 (See Notes) 1'51/2 120 41.442 Flow (q) from Route 13 T(15'-O) , 0.009990 13 12'-2 104.81 3.3340 1656 0.164 41.606 Total(Pt) Route 7 110 13'-6 5.6 19.80 1 (See Notes) 0-8 120 12.505 •••"Route 8•"•• Sprinkler, T(5'0) 5-0 0.127769 0.289 35 12'-10 19.80 1.0490 5-8 0.724 .13.518 Total(Pt) Route 8 111 13'-6 5.6 20.13 1 (See Notes) . 0-8 120 12.920 Route Sprinkler, T(5'0) 5-0 0.131684 0.289 8 12-10 20.13 1.0490 5-8 0.746 13.955 Total(Pt) Route 9 112 13'-6 5.6 20.53 1 (See Notes) 0-8 120 13.445 ••••• Route lO••••• Sprinkler, E(2'-O) 2-0 0.136625 0.289 61 12'-10 .' 20.53 1.0490 2-8 0.364 61 12'-10 1% (See Notes) 4'4V2 120 14.098 T(6'-O) 6-0 0.035933 24 12'lo 20.53 1.3800 10-4% 0.373 14.471 Total(Pt) Route 10 lk,©M.E.P.CAD, Inc. ffi AutoSPRlNK®12v12.0.61.0 1 12/19/2017 11:21:33AM Page 5 Job Name: Drawing3 Remote Area Number Date 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID ces Fittings & (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting!Device (Equivalent Length) Fixed Pressure Losses, when are added directly to ne n as gative a Fitting Pf Friction Loss Per Unit (psi) Elev(Pe) applicable, Node 2 Total Flow Actual ID (Foot) Friction(Pf) 113 13-6 5.6 20.57 1 (See Notes) 0-8 120 13.496 •••• Route 11 Sprinkler. T(5'-O) 5-0 0.137111 0.289 38 12-10 20.57 1.0490 5'8 0.777 14.562 Total(Pt) Route 11 114 13'-6 1 5.6 20.63 1 (See Notes) 0-8 120 13.577 Route 12 Sprinkler. E(2'-O) 2-0 0.137873 0.289 65 12'-10 20.63 1.0490 2-8 0.368 65 12'-10 1v4 (See Notes) 441/2 120 14.234 T(6'-O) 0.036261 43 12'-10 20.63 1.3800 rl 0.377 14.611 Total(Pt) Route 12 115 13'-6 1 5.6 23.69 1 (See Notes) 0-8 120 17.900 Route 13 Sprinkler, T(5'-O) 5-0 0.178038 0.289 67 12-10 23.69 1.0490 5-8 1.009 67 12-10 26.87 14 (See Notes) • 86-6 120 19.198 Flow (q) from Route 16 6E(3'-0), T(6'-0) 24-0 0.190334 -0.000 _____ 68 _________ 12'-10 _________ 50.56 _______ 1.3800 109-6 20.843 68 12'-10 11/4 (See Notes) 0'8 120 40.041 P0(6-0) 6-0 0.166749 0.289 60 12-2 OR V10,11 50.56 1.4180 6'-8 1.112 41.442 Total(Pt) Route 13 69 3-6 250.00 6 (See Notes) 4-6 140 50.117 ••••• Route 14'•••• Hydrant, E(23'-l%) 23'-1V2 0.001640 1.951 73 -1-0 '4 250.00 6.3400 27'-7% 0.045 73 10 - 6 (See Notes) 23'-9 150 52.113 T(16'-10) 16-10 0.004818 -0.000 6 -1-0 250.00 4.9500 40 '-7 0.196 6 -11-0 10 (See Notes) 990l/2 150 52.309 EE(5'-8) 5-8 0.000455 1.301 19 -4-0 '010 250.00 8.0360 104'-8% 0.048 53.657 Total(Pt) Route 14 , © M.E.P.CAD, Inc. AutoSPRINK® 12 v1 2.0.61.0 1 12/19/2017 11:21:33AM Page 6 Job Name: Drawing3 Remote Area Number: Date: 12/19/2017 Pipe Information Node 1 Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Pressure Losses, applicable, are added directly to (PQ and shown as a negative value. Fitting (Foot) Pf Friction Los: Per Unit Elev(Pe) Node 2 Elev2 Total Flow Actual ID Total (Foot) Friction(Pf) 75 12'-10 26.89 1% (See Notes) 0-8 120 40.766 ••"• Route 15..... Flow (q) from Route 19 PO(6-0) 6-0 0.051864 0.289 76 12-2 26.89 1.4180 6-8 0.346 76 12-2 3 11-1 120 41.400 0.000807 59 12-2 26.89 3.3340 • 11-1 0.009 41.409 Total(Pt) Route 15 48 12-2 1% (See Notes) 0-8 120 16.645 "" Route 16""' P0(6-0) 6-0 0.051774 -0.289 77 12-10 26.87 1.4180 6-8 0.345 77 12-10 ____________ 11/14 (See Notes) 363 120 16.702 ' T(6-0) 6-0 0.059097 67 12-10 ON 26.87 1.3800 42-3 2.496 19.198 Total(Pt) Route 16 32 12-10 1% 6-7% 120 13.224 ••••• Route 17•••• 0.031302 42 12-10 i.6 MWIN 19.06 1.3800 6-7% 0.207 13.431 Total(Pt) Route 17 5 12-10 1% 8-6 120 12.870 Route 18 0.000745 20 12-10 2.53 1.3800 8 -6 0.006 12.877 Total(Pt) Route 18 55 12-10 1% (See Notes) 56-11 120 36.864 •••• *Route 19••••• E(3-0), T(6'-O) 9-0 0.059199 -0.000 75 12-10 26.89 1.3800 65-11 3.902 VMOMM 40.766 Total(Pt) Route 19 25 12-2 21/2 15'-0 120 16.376 ••"• Route 20••••• 0.001500 47 12-2 21.69 2.7050 15-0 0.023 16.399 Total(Pt) Route 20 CM,© M.E.P.CAD, Inc. rij AutoSPRINK® 12 v1 2.0.61.0 1 12/19/2017 11:21:33AM Page 7 Job Name: Drawing3 Remote Area Number: 1 Date: 12/19/2017 IvLI Actual Inside Diameter 4.87 = F Schedule 40 Steel Pipe Inside Diameter) Factor Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 tti fl ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connecti fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run I U Union WirF Wirsbo WMV Water Meter Valve Z Cap ,©M.E.P.CAD, Inc. AutoSPRlNK®12v12.0.61.0 1 12/19/2017 11:21:33AM Page 8 eydraulic Calculation for Project Name: Drawing3 Location: Drawing Name: Building B 1ST & 2nd Floor Piping Design Remote Area Number: 2 Remote Area Location: BLDG B LEV 2 Occupancy Classification: Ordinary Group I Commodity Classification: N/A Calculation Date: 12/19/20.17 Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: 0.1 50g pm/ft2 1500.00ft2 (Actual 1514.94ft2) 127. 50ft2 Upright 13 Type of System: WET Volume of Dry or PreAction System: N/A In-rack Demand: N/Agpm at Node: N/A Hose Streams: 0.0 gpm at Node: I Type: Allowance at Source 250.00 at Node: 69 Type: Hydrant Total Water Required (including Hose Streams where applicable): From Water Supply at Node 1: 512.06@58.010 Water Supply Information: Name of Contractor: Address: Phone Number: Authority Having Jurisdiction: Notes Automatic peaking results Name of designer: Left: 58.760 Right: N/A f&© M.E.P.CAD, Inc. AutoSPRlNK® 12 v12.0.61.0 2 12/19/201711:22:4OAM Page 1 IC4 _____________ _____________ _______ Job Number: 1 7 LIFT LOT #23 Report D escription: Ordinary Group 1(2) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Hydrant 69 250.00 250.00 0 52.485 c Sprinkler 201 19.31 19.31 5.6 11.890 Sprinkler 202 19.34 19.31 5.6 11.930 Sprinkler 203 19.40 19.31 5.6 12.003 Sprinkler 204 19.58 19.31 5.6 12.219 Sprinkler 205 19.59 19.31 5.6 12.234 Sprinkler 206 19.63 19.31 5.6 12.288 Sprinkler 207 19.71 19.31 5.6 12.390 Sprinkler 208 19.82 19.31 5.6 12.529 Sprinkler 209 19.92 19.31 5.6 12.650 Sprinkler 210 20.33 19.31 5.6 13:174 Sprinkler 211 21.07 19.31 5.6 14.150 Sprinkler 212 21.12 19.31 5.6 14.222 Sprinkler 213 23.25 19.31 5.6 17.244 c Most Demanding Sprinkler Data . © M.E.P.CAD. Inc. i]Y AutoSPRINK® 12 v12.0.61.0 12/19/2017 11:23:34AM Paae 1 Hydraulic Graph Job Name: Drawing3 N 1.85 Remote Area Number: 2 Date: 12/19/2017 ioo--- Water Supply —: - [Summary Sheet go Node 80—. Static Pressure 74.000 512.06 J@ 73.727 70 60— 512.06@58.01 4925.00 @ 56.000 S stem demand curve 30- 10 0__1r.LU.LLLhhhhhhhhhhhhhhhhh1 111111111 111111111 11111111 11111111 liii I I II I II I I I 0950 1900 2850 4750 5700 6650 7600 8550 9500 Flow - gpm S iA,© M.E.P.CAD, Inc. AutoSPRINK® 12 02.0.61.0 12/19/2017 11:22:41AM Pape 2 Job Name: Drawing3 Remote Area Number: Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equuv. Length Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value. Filling (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) 17 Total Flow (Q) Actual ID Total Friction(PO 201 29'-1 5.6 19.31 1 (See Notes) 0'8 120 11.890 ' Route I Sprinkler, T(5'-O) 5-0 0.121948 0.289 22 28-5 . 19.31 1.0490 68 0.691 22 28-5 1% 8-6 120 12.870 .004911 0.004911 '-6 23 28-5 7.00 1.3800 8-6 0.042 23 28-5 19.34 1 6'-7% 120 12.912 Flow (q) from Route 2 0.056981 26 28-5 H 26.34 1.3800 6'-7% 0.378 26 28'-5 19.63 1% (See 6-8 120 13.289 Flow (q) from Route 6 T(6'-O) 0.159630 27 28-5 45.98 1.3800 11-8 1.864 27 28'-5 21.07 1Y 2 (See Notes) 0'6 120 15.154 Flow (q) from Route 11 P0(8-0) 8-0 0.132774 0.217 29 27-11 • 67.04 1.6540 8-6 1.129 29 27-11 21/2 6'-O% 120 16.499 0010047 33 27'-11 6064 27050 6 01/2 0.061 33 27'-11 11/2 (See Notes) 0'6 120 16.560 P0(8 0) 8-0 0.110263 -0.217 36 28'-5 60.64 1.6540 8'-6 0.937 36 28'-5 1% (See Notesi / 165'3 120 17.280 E(40) 3E(4'O), C(8'-O), T(8'O) 32-0 0.089096 37 28'-5 60.64 1.7280 197-3 17.574 37 28'-5 11/2 (See Notes) 0'6 120 34.855 P0(8-0) 8-0 0.110263 0.217 40 27'-11 60.64 1.6540 8-6 0.937 40 2711 51.63 3 5-8 120 36. 009 Flow (q) from Route 3 0.011343 41 27'-11 112.26 3.3340 5-8 0.065 41 27-11 5548 3 (See Notes) 9'- 111/2 120 36.073 Flow (q) from Route 7 T(1 5'-O) 15-0 0.023846 44 27-11 167.74 3.3340 24-111/2 0.595 1.,©M.E.P.CAD, Inc. F11 AutoSPRlNK®12v12.O.61.O 2 12/19/2017 11:22:43AM Page 3 Job Name: Drawing3 Remote Area Number: n Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fillings & Devices E Length (Foot) Length (Foot) C Factor Total(Pt) Notes Filling/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P1) and shown as a negative value. Fitting F (00) Pf Friction Loss Per Unit Elev(Pe) Node 2 Elev2 00) Total Flow Actual ID Total (Foot) Friction(Pf) 44 27'-11 94.32 3 (See Notes) 6'O% 120 36.669 Flow (q) from Route 4 E(7 0) 7'-0 0054433 45 27'-11 26206 33340 13 % 0.710 45 27'-ii 3 22-101/2 120 37.379 0054433 9.909 15 5 0% 26206 33340 22'-101/2 1.244 15 5-% 3 (See Notes) 11-1 120 48.532 CV(21 6) BV(13 5%) 34-111/2 0.060720 0.678 16 3 6 262 06 3 2600 36 0% 2.188 16 3-6 3 (See Notes) 3'-0 120 51.398 E(10-2%) 4BOR 10-21/2 0056051 1.299 17 0'-6 1 26206 33140 13 2 0.739 17 0-6 6 (See Notes) 13'3 140 53.435 2E(23--1%) 46'-21/2 0001789 1.951 18 4-0 26206 63400 0106 18 4-0 6 (See Notes) 72'7 150 55.493 3EE(3 11) T(16 10) , 0005256 19 4-0 262.06 4.9500 0 532 4-0 10 V-21/2 19 250.00 10 (See Notes) 51'0 150 56.025 Flow (q) from Route 14 2EE(5 8) 11-4 0001714 .1.301 4 -11-0 51206 80360 624 0.107 4 -i'-o 10 _______ (See Notes) 87% 140 54.831 E(36 1) BFP( 3 000) 36-1 0.000539 -1.734 3 3 0 - 512.06 104600 44 8 3 024 3 3-0 8 (See Notes) 911 140 56.121 2E(31'71/2) 63'-3 0.001525 1.734 2 -1-0 512.06 8.4500 72-4 0.110 2 -1-0 12 (See Notes) 60'0 150 57.965 Water Supply 0000746 1 1 0 51206 95320 60 0 0045 0.00 58.010 Hose Allowance At Source Total(Pt) Route 1 1 512.06 ,©M.E.P.CAD, Inc. AutoSPRlNK®12v12.0.61.0 2 12/19/2017 11:22:43AM Page 4 Job Name: Drawing3 Remote Area Number: fl Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) - , Total Flow (Q) Actual ID Total (Foot) Friction(Pf) 202 29-1 5.6 19.34 1 (See Notes) 0'8 120 11.930 ••••• Route 2•••'. Sprinkler, T(5'-O) 5-0 0.122324 0.289 23 28-5 . 19.34 1.0490 5-8 0.693 12.912 Total(Pt) Route 2 203 29'-1 5.6 19.40 1 (See Notes) 0'8 120 12.003 •••••Route3••'• Sprinkler, T(5'-O) 5-0 0.123014 0.289 46 28'-5 • 19.40 1.0490 5-8 0.697 46 28-5 12.31 11/4 8-6 120 12.989 Flow (q) from Route 18 0.080281 49 28-5 31.71 1.3800 8-6 0.682 49 28-5 19.92 11/4 (See Notes) 90'2V2 120 13.671 Flow (q) from Route 9 4E(3'-0), T(6'-0) 18-0 0.197810 -0.000 50 28'5 : 51.63 1.3800 108'-2% 21.402 50 28'-5 11,i2 (See Notes) 0'6 120 35.074 P0(8 0) 8'-O 0081882 0.217 52 27-11 5163 16540 8 6 0696 52 27-11 3 8'-4 120 35.986 0.002695 40 27'-11 51.63 3.3340 0.022 36.009 Total(Pt) Route 3 204 29-1 5.6 19.58 1 (See Notes) 0-8 120 12.219 ••••• Route 4•'•• Sprinkler, T(5'-O) 5-0 0.125066 0.289 54 28-5 :. 19.58 1.0490 5-8 0.709 54 28'-5 1% 8-6 120 13.217 0.001849 56 28-5 4.13 1.3800 8 -6 0.016 56 28-5 19.59 iv4 6'7% 120 13.233 Flow (q) from Route 5 0.046917 58 28-5 23.72 1.3800 6-7% 0.311 58 28-5 19.82 11/4 (See Notes) 68 120 13.543 Flow (q) from Route 8 1(6-0) 6'-O 0.144339 62 28-5 43.54 1.3800 11-8 1.686 ,©M.E.P.CAD, Inc. Fjj AutoSPRlNK®12v12.0.61.0 2 12/19/2017 11:22:43AM Page 5 Job Name: Drawing3 Remote Area Number: O Date: 12/19/2017 Pipe Information Node 1 Elev I (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) :i: Total Flow (Q) Actual ID LengthTotal (psi) Friction(Pf) 62 28-5 21.12 11/2 (See Notes) 0'6 120 15.229 Flow (q) from Route 12 P0(80) 8'-0 0124179 0.217 63 2711 6466 16540 86 1.056 63 27-11 6.41 1 2/2 14'-4 120 16.501 Flow (q) from Route 20 013476 0.013476 '-4 64 27'-11 7106 27050 144 0.193 64 27-11 21/2 15-0 120 16.695 0006639 66 27'-11 4847 27050 15'-0 0.100 66 27-11 11/2 (See Notes) 0'6 120 16.794 P0(8-0) 8'-0 072861 0.072861 '-6 -0.217 70 285 4847 16540 86 0.619 70 28'-5 1% (See Notes) 71'9 120 17.197 T(60) 2E(3-0) T(6 0) 18'-0 0176016 71 28'-5 4847 13800 89 15795 71 28'-5 11/4 (See Notes) 50'11 120 32.992 2T(6 0) 12-0 0.049636 -0.000 72 28'-5 24.45 1.3800 62'-11 3.124 72 28-5 11/2 (See Notes) 0'-6 120 36.115 P0(80) 8-0 0020547 0.217 74 27'-11 2445 16540 86 0.175 74 27'-11 24.02 3 11-1 120 36.507 Flow (q) from Route 16 0002398 78 27'-11 4847 33340 11 1 0.027 78 27'-11 4585 3 (See Notes) 1'51/2 120 36.533 Flow (q) from Route 13 1(150) 15'-0 0008219 44 27--11 9432 33340 16 0.135 36.669 Total(Pt) Route 4 205 29-1 5.6 19.59 1 (See Notes) 0-8 120 12.234 ••• Route 5 ..... Sprinkler, T(5 0) 5-0 0 125207 0.289 56 28 5 19 59 1 0490 5 8 0 710 13.233 Total(Pt) Route 5 , 0 M.E.P.CAD, Inc. rll AutoSPRINK® 12 02.0.61.0 2 12/19/2017 11:22:43AM Page 6 Job Name: Drawing3 Remote Area Number: r L di Date: 12/19/2017 Pipe Information Node 1 Elev I (Foot) K-Factor Flow added this step q Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pt) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) -' ' Total Flow (Q Actual ID Total (Foot) Friction(Pf) 206 29'-1 5.6 19.63 1 (See Notes) 0-8 120 12.288 •••'' Route 6••••• Sprinkler T(50) 5-0 0.125718 0.289 26 28'-5 19.63 1.0490 6-8 0.712 13.289 Total(Pt) Route 6 207 29'-1 5.6 19.71 1 (See Notes) 0-8 120 12.390 ••"•Route 7••••' Sprinkler, T(5-0) 5-0 0.126686 0.289 79 28'-5 [ 19.71 1.0490 5-8 0.718 79 28'-5 15.44 1% 8'-6 120 13.397 Flow (q) from Route 17 0.097176 80 28'-5 1, - 35.16 1.3800 8-6 0.826 80 28'-5 20.33 1% (See Notes) 80'2% 120 14.223 Flow (q) from Route 10 2E(3'-0),T(6-0) 12-0 0.226015 -0.000 81 28'-5 55.48 1.3800 92'-2% 20.838 81 28'-5 11/2 (See Notes) 06 120 35.061 P0(8-0) 8-0 0.093558 0.217 41 27-11 55.48 1.6540 8'-6 0.795 36.073 Total(Pt) Route 7 208 29'-1 5.6 19.82 1 (See Notes) 0'-8 120 12.529 ""Route 8"'' Sprinkler, T(5 0) 5-0 0.127997 0.289 58 28'-5 19.82 1.0490 6-8 0.725 13.543 Total(Pt) Route 8 209 29-1 5.6 19.92 1 (See Notes) 0-8 120 12.650 ''••Route9••••' Sprinkler, T(5'-O) 5-0 0.129142 0.289 49 28'-5 19.92 1.0490 5-8 0.732 13.671 Total(Pt) Route 9 210 29-1 5.6 20.33 1 (See Notes) 0-8 120 13.174 •••• *Route lO••••• Sprinkler, T(5'-O) 5-0 0.134084 0.289 80 28'-5 . 20.33 1.0490 5'-8 0.760 14.223 Total(Pt) Route 10 211 29-1 5.6 21.07 1 (See Notes) 0-8 120 14.150 "" Route ll"" Sprinkler, E(2-0) 2-0 0.143246 0.289 82 28-5 21.07 1.0490 2-8 0.382 ©M.E.P.CAD, Inc. ffi AutoSPRINK®12v12.O.61.O 2 12/19/2017 11:22:43AM Page 7 Job Name: Drawing3 Remote Area Number: 2 Date: 12/19/2017 Pipe Information Elev I Flow added Fillings & Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Filling/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv Length) Fixed Pressure Losses, when Node 2 Total Flow Actual ID Length Loss Per Unit applicable, are added directly Total (Foot) (psi) Friction(Pf) to (P1) and shown as a (Foot) negative value. 82 28'-5 1% (See 2'10 120 14.821 Notes) 6'-0 :'-- - 27 28'-5 21.07 1.3800 0.037674 T(6-0) 8'-lO 0.332 7. 15.154 Total(Pt) Route 11 212 29'-1 5.6 21.12 1 (See 0-8 120 14.222 •••.• Route 12••••. Notes) Sprinkler, 2'-O 0.289 83 28'-S 21.12 1.0490 0.143920 E(2'-O) 2'-8 0.384 83 28-5 1% (See 2'10 120 14.895 Notes) 62 28-5 21.12 1.3800 0.037852 T(6'O) 8'-lO 0.334 15.229 Total(Pt) Route 12 213 29'-1 5.6 23.25 1 (See 0-8 120 17.244 ••••'Route13•••• Notes) Sprinkler, 5-0 0.289 84 28'-5 23.25 1.0490 0.171993 T(5 0) 6-8 0 84 28'-5 22.60 1% (See 84'7/2 120 18.507 Notes) Flow (q) from Route 15 24-0 -0.000 85 28'-5 4585 1 3800 0.158823 6E(3-0) T(6 0) 108 17250 85 28-5 11,4 (See 0'6 120 35.758 Notes) 8-0 0.217 78 27'-11 45.85 1.6540 0.065744 P0(8-0) 8-6 0.559 36.533 Total(Pt) Route 13 69 3'-6 250.00 6 (See 4-6 140 52.485 •'' Route 14 - Notes) Hydrant, 23'-VA 1.951 73 -11-0 250.00 6.3400 0.001640 E(23'-l%) 277h,4 0.045 73 10 6 (See 23-9 150 54.481 Notes) T(16'-10) 16-10 0.004818 -0.000 6 -1-0 250.00 4.9500 40'7 0.196 6 -i'-o 10 (See 991 01/2 150 54.676 ___ ______ ___________ Notes) 5'-8 1.301 - 19 -4-0 .'• 250.00 8.0360 0.000455 EE(5-8) 104'-8% 0.048 56.025 Total(Pt) Route 14 , 0 M.E.P.CAD, Inc. @11 AutoSPRINK® 12 v12.0.61.0 2 12/19/2017 11:22:43AM Page 8 Job Name: Drawing3 Remote Area Number: 2 Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step Nominal ID Fittings & Devices Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when are added directly to (Pt) and shown as a negative value. Fitting Pf Friction Loss Per Unit (psi) Elev(Pe) applicable, Node 2 Aa, Total Flow Actual ID (Foot) Friction(Pf) 64 27'-11 1% (See Notes) 0-6 120 16.695 Route 15-- P0(8-0) 8-0 0.017755 -0.217 86 28-5 22.60 1.6540 8-6 0.151 86 28-5 iv4 (See Notes) 37'91/2 120 16.629 T(60) 0.042892 84 28-5 22.60 1.3800 4391/ 1.879 18.507 Total(Pt) Route 15 87 28-5 24.02 11/2 (See Notes) 0-6 120 36.114 •••• Route 16. Flow (q) from Route 19 PO(8-0) 8-0 0.019878 0.217 88 27-11 24.02 1.6540 8'-6 0.169 88 27-11 3 11,-1 120 36.499 0.000654 74 27'-11 24.02 3.3340 0.007 36.507 Total(Pt) Route 16 54 28'-5 1¼ 8'-6 120 13.217 ••••• Route 17•••• 0.021217 79 28-5 15.44 1.3800 8-6 0.180 13.397 Total(Pt) Route 17 22 28'-5 1¼ 8-6 120 12.870 ••••• Route 18•"•• 0.013939 46 28-5 12.31 1.3800 8'-6 0.118 12.989 Total(Pt) Route 18 71 28-5 1¼ (See Notes) 56-0 120 32.992 "" Route 19''" E(3-0), 1(6-0) 90 0.048021 -0.000 87 28-5 ______ 24.02 1.3800 65-0 3.122 36.114 Total(Pt) Route 19 29 27-11 2% 15-0 120 16.499 •••••Route 20•••• .000157 0.000157 '-0 63 27'-11 6.41 2.7050 15-0 0.002 16.501 Total(Pt) Route 20 © M.E.P.CAD, Inc. Lffl AutoSPRlNK® 12 v12.0.61.0 2 12/19/2017 11:22:43AM Page 9 Job Name: Drawing3 Remote Area Number: 2 Date: 12/19/2017 IiiI Actual Inside Diameter 4.87 = Factor Schedule 40 Steel Pipe Inside Diameter) Value Of 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 irr - ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connectic fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD, Inc. rig AutoSPRINK® 12 v12.0.61.0 2 12/19/2017 11:22:43AM Page 10 eydraulic Calculations. for Project Name: Drawing2 Location:, Drawing Name: Building A 1ST& 2nd Floor Piping rev 10-31-17 Design Remote Area Number: 3 Remote Area Location: BLDG A LEV I Occupancy Classification: Ordinary Group I Commodity Classification: N/A Calculation Date: 12/19/2017 Density: 0.150gpm/ft2 Area of Application: 1500.0.0ft2 (Actual 1561.73ft2) Coverage per Sprinkler: 100.00ft2 Type of sprinklers calculated: Upright No. of sprinklers calculated: 12 Type of System: WET Volume of Dry or PreAction System: N/A In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: 46 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node 46: 494.23@46.637 Water Supply Information: Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes Automatic peaking results Left: N/A Right: N/A (© M.E.P.CAD, Inc. AutoSPRINK® 12v12.0.61.0 3 12/19/201712:47:32PM Page 1 S Job Number: 1 - LIFT LOT #23 Reoort Descriotion: Ordinary GrouD I (3) Device Actual Flow. (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Hydrant 76 250.00 250.00 0 41.419 c Sprinkler 101 19.50 19.50 5.6 12.125 Sprinkler 102 19.51 19.50 5.6 12.132 Sprinkler 103 19.52 19.50 5.6 12.146 Sprinkler 104 19.52 19.50 5.6 12.153 Sprinkler 105 19.68 19.50 5.6 12.345 Sprinkler 106 19.69 19.50 5.6 12.365 Sprinkler 107 19.79 19:50 5.6 12.494 Sprinkler 108 19.81 19.50 5.6 12.517 Sprinkler 109 20.28 19.50 5.6 13.115 Sprinkler 110 20.29 19.50 5.6 13.132 Sprinkler 111 23.29 19.50 5.6 17.290 Sprinkler 112 23.35 19.50 5.6 17.382 c Most Demanding Sprinkler Data 1, © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 12/19/2017 12:48:04PM Page 1 Hydraulic Graph Job Name: Drawing2 S N 1.85 Remote Area Number: 3 Date: 12/19/2017 1O0 .. SWater upply __[_SurnrnarYSheet Node: 46 80-i Available Supply Static Pressure 74.000 494.23..@ 73.744 60 : - - 492500 @ 56000 50-- P4,23@ 46.637 Zn 40 :: i :____ _ Is stem demand curve 20 0—.IIJJ.LLIJ!IIIIIIIIIIIIItIII 111111111 111111111 111111111 111111 I 11111111 II II I I I 0950 1900 2850 3800 4750 5700 6650 7600 8550 9500 Flow - gpm S (,© M.E.RCAD, Inc. AutoSPRINK® 12 02.0.61.0 12/19/2017 12:47:34PM Page 2 J6b Name: Drawing2 Remote Area Number: 3 Date: 12/19/2017 Pipe Information Node 1 Elev (Foot) K-Factor Flow added this step (q) Nominal ID Fillings & Devices Equiv. Length Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses,. when applicable, are added directly to (P1) and shown as a negativevalue. Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total Friction(P1) 101 13'-6 5.6 19.50 1 (See Notes'/ 0-8 120 12.125 ••••'Routel••••. Sprinkler,, T(5'-O) 5-0 0.124177 0.289 I 12'-10 19.50 1.0490 68 0.704 1 12'-10 iv4 9'3 120 13.118 0.025072 2 . 12'-10 16.90 1.3800 0.232 2 12-10 19.68 1/4 7'-g 120 13.350 Flow (q) from Route 5 ., 0.104576 3 12-10 36.58 1.3800 0.810 3 12-10 20.28 1% (See 8'-s% 120 14.160 Flow (q) from Route 9 T(6'-O), P0(6-0) 12-0 0.236498 0289 4 12'-2 56.86 1.3800 . 2051/2 4.840 4 12'-2 21,4 10-5 120 19.290 0.004444 5 12-2 39.02 2.7050 10'-5 0.046 5 • 12-2 i 1/4 (See 0'8 120 19.336 - 6-0 Notes ' 0.117827 -0.289 6 12-10 39.02 1.3800 6-8 0.786 6 12-10 5.45 1,4 (See Notes) 145'8 120 19.833 P0(8-U), Flow (q) from Route 1 15 T(80) 16-0 0.050194 7 12-10 44.46 1.7280 - 8.115 7 12-10 1% (See Notes) 0'8 120 27.947 P0(6-0) 6'-0 0.150064 0.289 10 12'-2 44.46 1.3800 6-8 1.000 10 12-2 3 10'-5 120 29.237 0.002045 13 12'-2 .44.46 3.3340 10'-5 0.021 13 12-2 41.90 14'-O 120 29.258 Flow (q) from Route 2 0.006982 15 12-2 86.36 3.3340 14'-0 0.098 15 122 42.00 3 14-0 120 29.356 Flow (q) from Route 3 . 0014536 16 12-2 128.36 3.3340 14-0 0.203 ,©M.E.P.CAD, Inc. AutoSPRlNK®12v12.0.61.O 3 12/19/2017 12:50:59PM Page 1 Job Name: Drawing2 Remote Area Number: 3 Date: 12/19/2017 Pipe Information Elev i Flow added Fillings & Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent (Foot) Pf Friction Fitting Length) Elev(Pe) (q) Equiv. Fixed Pressure Losses, when Node 2 Elev 2 Total Flow Actual ID Length Loss Per Unit applicable, are added directly Total (Foot) (Q) (psi) Friction(Pf) to (PQ and shown as a (Foot) - negative value. 16 12'-2 3386 3 14'-0 120 29.559 Flow (q) from Route 12 0.022415 17 12'-2 162.23 3.3340 14-0 0.314 17 12'-2 2684 3 14-0 120 29.873 Flow(q) from Route 16 0.029754 21 12'-2 189.07 3.3340 14-0 0.417 21 12'-2 27 . 23 3 14'-0 120 30.290 Flow (q) from Route 6 0.038165 0.534 23 12'-2 EM -z 216.30 3.3340 1 23 12-2 27.92 3 (See - 0% 120 30.824 Notes Flow (q) from Route 14 E(7-0),T(15'-0) 0.047777 28 12-2 244.23 3.3340 1.676 28 12-2 3 7'-l% 120 32.500 0.047777 3.081 7-1% 0.340 29 5-0% 1 DOM - 244.23 3.3340 29 5-0% 3 (See 11-1 120 35.920 Notes) 34'11 / 0.678 30 3'-6 244.23 3.2600 0.053296 CV(21'-6), BV(13'-5%) 36'-0% 1.920 30 3-6 . 3 (See 3'-0 120 38.518 Notes) , 0.049198 25 0'-6 244.23 3.3140 E(10'-2%), 6BOR 0.649 25 0'-6 6 (See 13'3% 140 40.466 Notes) 46'-2Y2 0.001571 1.951 0.093 27 -4-0 244.23 6.3400 2E(23--1 %) 27 4-0 6 (See 26'8 150 42.510 Notes) , 32 -4-0 244.23 4.9500 0.004614 E(7'-lO%) 346% 0.159 32 4-0 8 (See 45'7% 150 42.669 Notes) , 0.867 33 -6-0 244.23 6.4470 0.001274 2EE(4'-9%) 56 0.070 33 -6'-0 6 -0 2 50.00 8 (See 354'11% 150 43.607 Notes) Flow (q) from Route 13 1(18 8%) 0004694 168 34 11-0 49423 64470 1.754 ,©M.E.P.CAD, Inc. @11 AutoSPRINK®12v12.0.61.0 3 12/19/2017 12:50:59PM Page 2 Job Name: Drawing2 Remote Area Number: 3 Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fillings & Devices Equiv. Length Length (Foot) C Factor Total(Pt) Notes Filling/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P1) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) Total Flow (Q) Actual ID Total Friction(Pfi 34 -1-0 10 (See Notes) 149'4% 150 43.193 2EE(5-8) 1 E(1 4) 0001605 36 11-0 49423 80360 172 0276 36 -1-0 • 10 (See Notes) 8'7% 140 43.469 E(36'-oh), BFP(-3.000) 36'-0% -1.734 39 3'-0 : 494.23 10.4600 4481/ 3.023 3-0 8 (See Notes) 91-1 140 44.758 2E(31-7%) 63'-2h 0.001428 1.734 42 -1'-0 494.23 8.4500 72'3/ 0.103 42 -11-0 12 (See Notes) 60'0 150 46.595 Water Supply 0.000699 46 -11-0 494.23 9.5320 60'-0 0.042 0.00 46.637 Hose Allowance At Source Total(Pt) Route I 46 494.23 102 13-6 5.6 19.51 1 (See Notes' 0-8 120 12.132 •••Route 2••••• Sprinkler, T(5'-O) 5-0 0.124242 0.289 47 12'-10 19.51 1.0490 5-8 0.704 47 12-10 2.60 1 ' 9'-3 120 13.125 Flow (q) from Route 19 0041177 48 12'-10 2210 13800 0.381 48 12'-10 19.79 i/ (See Notes) 103'O% 120 13.506 Flow (q) from Route 7 T(6 0) P0(6 0) 12-0 0134421 0.289 13 12 2 4190 13800 115'-0'/2 15.463 29.258 Total(Pt) Route 2 103 13'-6 5.6 19.52 1 (See Notes) 0'8 120 12.146 •••" Route 3•"•• Sprinkler, T(5'-O) 5'-0 0.124372 0.289 50 12-10 : 19.52 1.0490 6-8 0.705 50 12-10 1% 9-3 120 13.140 53 12 2.67 0.000824'-10 1.3800 0.008 53 1210 19.52 1 1/4 9-3 120 13.147 Flow (q) from Route 4 0.041480 55 12-10 22.19 1.3800 0.384 , © M.E.P.CAD, Inc. @JU AutoSPRINK® 12 v1 2.0.61.0 3 12/19/2017 12:50:59PM Page 3 Job Name: Drawing2 Remote Area Number: 3 Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step q Nominal 'D Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit Total (ps Elev(Pe) Node ,2 Elev 2 (Foot) Total Flow Actual ID (Foot) Friction(Pf) 55 12-10 19.81 11/4 (See Notes) 103'-0Y2 120 13.531 Flow (q) from Route 8 T(6-0), PO(6'-O) 12-0 116-01/2 0.135055 0.289 15 12'-2 42.00 1.3800 15.536 29.356 Total(Pt) Route 3 104 13'-6 5.6 19.52 1 (See Notes) 0'-8 120 12.153 •••••Route 4••••• Sprinkler, T(5'-O) 5-0 0.124440 0.289 53 12-10 19.52 1.0490 5'-8 0.705 13.147 Total(Pt) Route 4 105 13-6 5.6 19.68 1 (See Notes) 0'-8 120 12.345 Route 5 ..... Sprinkler, T(5-0) 5-0 0.126260 0.289 2 12'-10 19.68 1.0490 5-8 0.715 13.350 Total(Pt) Route 5 106 13-6 5.6 19.69 1 (See Notes) 0-8 120 12.365 •••• Route 6 Sprinkler, T(5-0) 5-0 0.126443 0.289 61 12'-10 19.69 1.0490 5'-8 0.717 61 12'-10 16.85 11/4 7-9 120 13.370 Flow (q) from Route 20 0.104368 62 12-10 36.54 1.3800 7-9 0.809 62 12'-10 20.29 1% (See Notes) 8'-5% 120 14.179 Flow (q) from Route 10 T(6-0), P0(6-0) 12-0 0.236300 0.289 64 12'-2 ' ¶ 56.83 1.3800 20-5% 4.836 64 12'-2 17.84 21/2 14-0 120 19.304 Flow (q) from Route 17 0.014771 65 12-2 74.68 2.7050 140 0.207 65 12'-2 12.77 21/2 14-0 120 19.511 Flow (q) from Route 11 0.019780 66 12-2 87.45 2.7050 14-0 0.277 66 12'-2 21/2 14'-0 120 19.788 0.010039 69 12-2 60.61 2.7050 14-0 0.141 69 12-2 1% (See Notes) 147'0 120 19.929 PO(6'-O) 2T(6-0), P0(6-0) 24'-0 0.060590 21 12'-2 27.23 1.3800 -- r 171-0 10.361 ,©M.E.P.CAD, Inc. AutoSPRlNK®12v12.0.61.0 3 12/19/2017 12:50:59PM Page 4 Job Name: Drawing2 Remote Area Number: 3 Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step q Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (PQ and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (ps . Elev(Pe) Node 2 Elev 2 (Foot) = Total Flow Actual ID Total (Foot) Friction(PO 30.290 Total(Pt) Route 6 107 13-6 5.6 19.79 1 (See Notes) 0'-8 120 12.494 •••••Route 7••••• Sprinkler, T(5'O) 5'O 0.127663 0.289 48 12-10 i A 19.79 1.0490 6-8 0.723 13.506 Total(Pt) Route 7 108 13'-6 5.6 19.81 1 (See Notes) 0'-8 120 12.517 "Route8 Sprinkler, T(5-0) 5-0 0.127885 0.289 55 12'-10 19.81 1.0490 5-8 0.725 13.531 Total(Pt) Route 8 109 13'-6 5.6 20.28 1 (See Notes) 0-8 120 13.115 •••••Route 9••••• Sprinkler, T(5'-O) 5-0 0.133522 0.289 3 12-10 .:s1 20.28 1.0490 5-8 0.757 14.160 Total(Pt) Route 9 110 13-6 5.6 20.29 1 (See Notes) 0-8 120 13.132 ••••• Route 10•••• Sprinkler, T(5 0) 5-0 0.133689 0.289 62 12'-10 20.29 1.0490 6-8 0.758 14.179 Total(Pt) Route 10 111 13'-6 5.6 23.29 1 (See Notes) 0-8 120 17.290 ••••• Route 11.. Sprinkler, T(5-0) 5-0 0.172419 0.289 71 12-10 23.29 1.0490 5-8 0.977 71 12-10 1% (See Notes) 3271/2 120 18.556 T(6'-O), PO(6'-O) 12-0 0.014925 0.289 65 12-2 12.77 1.3800 0.666 19.511 Total(Pt) Route 11 112 13'-6 5.6 23.35 1 (See Notes) 0'-8 120 17.382 ••'••Route 12•••'' Sprinkler, T(5 0) 5'-O 0.173263 0.289 73 12'-10 23.35 1.0490 6-8 0.982 73 12'-10 10.52 1¼ (See Notes) 105'l% 120 18.652 Flow (q) from Route 18 T(6'-O), PO(6'-O) 12'-O 0.090660 0.289 16 12-2 33.86 1.3800 117-1% 10.618 29.559 Total(Pt) Route 12 ,©M.E.P.CAD, Inc. rOjj AutoSPRINK®12v12.O.61.0 3 12/19/2017 12:50:59PM Page 5 Job Name: Drawing2 Remote Area Number: 3 Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step q Nominal ID Fittings & Devices (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Pressure Losses, applicable, are added directly to (PI) and shown as a negative value. Le Equiv. Fitting (Foot) Pf Friction Loss P Unit Elev(Pe) Node 2 9ev2 00) - Total Flow Actual ID (Foot) Friction(Pf 76 4-6 250.00 6 (See Notes) 4'-6 140 41.419 "•• Route 13.".. Hydrant, E(23'-l%) 23-1% 0.001640 1.951 78 -6-0 250.00 6.3400 27'-7% 0.045 78 -6'-0 6 (See Notes) 22'11% 150 43.415 PO(16-101/4) 16101/4 .004818 0.004818 '-10 33 -6'-0 1• 250.00 4.9500 39-10 0.192 43.607 Total(Pt) Route 13 69 12-2 21/2 9-11% 120 19.929 ••"• Route 14"••' 0.003329 75 12-2 33.37 2.7050 0.033 75 12'-2 21/2 4-0% 120 19.962 0.002394 77 12'-2 ; 27.92 2.7050 4O1/ 0.010 77 12'-2 1% (See Notes) 1470 120 19.972 PO(6'O) 2T(6'-O), P0(6-0) 24-0 0.063464 23 12'-2 27.92 1.3800 171'-0 10.852 30.824 Total(Pt) Route 14 75 12-2 1% (See Notes) 0-8 120 19.962 "" Route 15"" PO(6'O) E(3 0) 9-0 0003087 -0.289 79 12'-10 545 13800 9 8 0030 79 12-10 11/2 (See Notes) 105'9% 120 19.703 T(8 0) E(4 0) P0(8 0) 20'-0 0.001033 0.000 6 12'-10 545 1.7280 125 0 130 19.833 Total(Pt) Route 15 66 12'-2 1% (See Notes) 147-0 120 19.788 "••Route 16•••• PO(6'O) 2T(6 0) P0(6 0) 24'-0 0.058976 17 12'-2 26.84 1.3800 171'-0 10.085 29.873 Total(Pt) Route 16 4 12'-2 21/2 14'-0 120 19.290 Route 1.7 ..... 0001045 64 12'-2 1784 27050 14 0 0.015 19.304 Total(Pt) Route 17 , © M.E.P.CAD, Inc. F11 AutoSPRINK® 12 v12.0.61.0 3 12/19/2017 12:50:59PM Page 6 Job Name: Drawing2 Remote Area Number: 3 Date: 12/19/2017 Pipe Information Elev I Flow added Fillings & Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) V Fitting/Device (Equivalent (q) Equiv. (Foot) Pf Friction Fitting Length) Elev(Pe) Fixed Pressure Losses, when Node 2 Elev 2 Total Flow Actual ID Loss Per Unit applicable, are added directly Total (Foot) (Q) (psi) Friction(PO to (PO and shown as a 00) negative value. 71 12'-10 1 9-3 120 18.556; •••••Route 18•••.. 0.010418 9-3 73 12'-10 10.52 1.3800 0.096 18.652 Total(Pt) Route 18 1 12-10 9'-3 120 13.118 Route 19 ... . 0.000784 0.007 47 12'-10 2.60 1.3800 13.125 Total(Pt) Route 19 50 12-10 1,'4 9-3 120 13.140 "Route 20"• 0.024922 0.231 61 12-10 16.85 1.3800 13.370 Total(Pt) Route 20 , © M.E.P.CAD, Inc. !j AutoSPRINK® 12 v12.0.61.0 3 12/19/2017 12:50:59PM Page 7 Job Name: Drawing2 Remote Area Number: 3 Date: 12/19/2017 I Actual Inside Diameter 4.87 =F Schedule 40 Steel Pipe Inside Diameter) Factor Value Of 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backfiow Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11W Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connectic fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out Ply Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD, Inc. F11 AutoSPRINK® 12 v12.0.61.0 3 12/19/2017 12:50:59PM Page 8 Oydraulic Calculations for Project Name: Drawing2 Location: Drawing Name: Building 'A 1ST & 2nd Floor Piping rev 10-31-17 Calculation Date: 12/19/2017 Design Remote Area Number: 4 Remote Area Location: BLDG A LEV II Occupancy Classification: Ordinary Group I Commodity Classification: N/A Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated No. of sprinklers calculated: 0.150g pm/ft2 1500.00ft2 (Actual 1562.08ft2) 100.00ft2 Upright 12 Type of System: WET Volume of Dry or PreAction System: N/A In-rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm at Node: 46 Type: Allowance at Source 250.00 at Node: 76 Type: Hydrant Total Water Required (including Hose Streams where applicable): From Water Supply at Node 46: 494.90 @55.571 Water Supply Information: Name of Contractor: Address: Phone Number: Name of designer: Authority Having Jurisdiction: Notes: Automatic peaking results Left: N/A Right: N/A 1&© M.E.P.CAD, Inc. AutoSPRlNK® 12 02.0.61.0 4 12/19/201712:48:47PM Page 1 mmm S Report Description: Ordinary Group 1(4) Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Hydrant 76 250.00 250.00 0 50.347 c Sprinkler 201 19.50 19.50 5.6 12.125 Sprinkler 202 19.52 19.50 5.6 12.145 Sprinkler . 203 19.55 19.50 5.6 12.189 Sprinkler 204 19.57 19.50 5.6 12.208 Sprinkler 205 19.62 19.50 5.6 12.280 Sprinkler 206 19.68 19.50 5.6 12.346 Sprinkler 207 19.86 19.50 5.6 12.571 Sprinkler 208 19.90 19.50 5.6 12.633 Sprinkler 210 20.24 19.50 5.6 13.060 Sprinkler 211 20.29 19.50 5.6 13.133 Sprinkler 212 23.55 19.50 5.6 17.678 Sprinkler 213 23.63 19.50 5.6 17.799 c Most Demanding Sprinkler Data . © M.E.P.CAD. Inc. 'i1!I AutoSPRINK® 12 v12.0.61.0 12/19/2017 12:49:01PM Pane 1 Hydraulic Graph Job Name: Drawing2 N 1.85 Remote Area Number: 4 Date: 12/19/2017 100— WaterSupply - [_SurnrnarY Sheet Node: 46 80-- - - Available Supply Static Pressure 74.000 494.90 c 73.743 70— - 60H -- 494.90 55.571 . . 25.56.O00 CD 50— (0 - ID - 40—— S stem demand curve 30- 20 10 0...U.LLLLLLuIIIIIIuI 111111111 111111111 111111111 1111111 I I II liii II III II I I I I I I I I I 0950 1900 2850 3800 4750 5700 6650 7600 8550 9500 Flow - gpm lk..©M.E.P.CAD, Inc. AutoSPRINK®12v12.0.61.0 12/19/2017 12:48:49PM Paqe2 Job Name: Drawing2 Remote Area Number: 4 Date: 12/19/2017 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) (q) Equiv. Length) Fixed Pressure Losses, when ---.--- Node 2 Elev 2 : - Total Flow Actual ID Length Loss Per Unit applicable, are added directly Total (Foot) V - (Q) (psi) Friction(Pf) to (Pf) and shown as a (Foot) negative value. 201 29'-1 5.6 19.50 1 (See 0-8 120 12.125 ' Route I Notes) / Sprinkler, 5'-O 0.289 8 28'-5 19.50 1.0490 0 124177 T(5 0) 6-8 0.704 8 28-5 1% 9-3 120 13.118 0002281 9 28'-5 463 13800 9 0.021 9 28-5 19.52 1/4 9'- 120 1393 13. Flow (q) from Route 2 0.048482 11 28'-5 24.14 1.3800 0.448 ii 28-5 19.86 (See 10501/2 120 13.588 Notes) Flow (q) from Route 7 12-0 0.289 12 27'-9 4400 13800 0147158 2E(3 0) P0(6 0) 117 01/2 17.222 12 27-9 35.33 14-0 120 31 .099 Flow (q) from Route 15 0005966 14 27'-9 7932 33340 14'-0 0.084 14 27-9 44.02 3 14-0 120 31.182 Flow (q) from Route 3 0013502 18 27'-9 12335 33340 14'-0 0.189 18 27-9 35.83 3 14-0 120 31 .371 Flow (q) from Route 12 021642 0.021642 '-0 19 27'-9 15918 33340 140 0.303 19 27-9 28.30 14'-O 120 31.674 Flow (q) from Route 16 0029294 20 27'-9 18748 33340 14 0 0.410 20 27-9 28.44 14'-0 120 32.085 - Flow (q) from Route 5 0038039 22 2T-9 - 21591 33340 14'-0 0.533 22 27'9 28.98 3 (See ii'-O% 120 32.617 Flow (q) from Route 14 14-0 0.000 - - -. 26 27'-9 244.90 3.3340 0.048021 2E(7 0) 25'-0% 1.204 26 27-9 3 16-7 120 33.821 6.756 28 12'-2 24490 32600 0053567 15 0.835 ,©M.E.P.CAD, Inc. §1 AutoSPRlNK®12v12.O.61.0 4 12/19/2017 12:51:56PM Page 1 Job Name: Drawing2 Remote Area Number: 4 Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices E Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable are added directly to (Pt) and shown as a negative value. Fitting F Pf Friction Loss Per Unit (psi) (psi) Elev(Pe) Node 2 e 2 (Foot) 1 Total Flow Actual ID Total (Foot) Friction(Pf) 28 12'-2 3 7-1% 120 41.412 0048021 3.081 29 5'-0% 24490 33340 7 1% 0.341 29 51-0% 3 (See Notes) l'i 120 44.834 CV(21 6) BV(13 5%) 34'-ii% 0.053567 0.678 30 T-6 244.90 3.2600 36 0% 1 930 30 3-6 3 (See Notes) 3'0 120 47.442 E(10-2%) 6BOR 10'-2% 0049449 1.299 25 0'-6 24490 33140 13-2% 0.652 25 0-6 6 (See Notes) 13'3% 140 49.393 2E(23 1%) 46'-2V2 0001579 1.951 27 4-0 24490 63400 0094 27 4-0 6 (See Notes) 268 150 51.437 E(7 10%) 7-10% 0004637 32 4-0 24490 49500 34 6% 0.160 32 4-0 8 (See Notes) 45'7% 150 51.597 2EE(4 9%) 91 7% 0001281 0.867 33 -6'-0 24490 64470 0071 33 -6'-0 250.00 8 (See Notes) 35411% 150 52.535 Flow (q) from Route 13 T(18 8%) 18'-8% 0004706 -2.168 34 -11-0 49490 64470 373 8 1.758 34 -11- 10 (See Notes) 149'43h 150 52.126 2EE(5 8) E(1 V-4) 22'-8% 0.001609 36 1 0 494.90 8 0360 172 1 0 277 36 -11-0 10 (See Notes) 8'7% 140 52.403 E(36 0%) BFP( 3000) 36-0% 0.000506 -1.734 39 3 0 494 90 104600 44'-8% 3 023 39 3-0 8 (See Notes) 91 1 140 53.692 2E(31 71/2) 63-2% 0001432 1.734 42 -11-0 49490 84500 72 0.104 42 ______ -11-0 __________ 12 (See Notes) 60'0 1.50 55.529 Water Supply 0 000701 46 -11-0 494.90 9.5320 60'-0 0.042 &@ M.E.P.CAD, Inc. Fig AutoSPRINK® 12 v12.0.61.0 4 12/19/2017 12:51:56PM Page 2 Job Name: Drawing2 Remote Area Number: 4 Date: 12/19/2017 Pipe Information Elev I Flow added Fittings & Length C Factor Total(Pt) Notes Node 1 (Foot) K-Factor this step Nominal ID Devices (Foot) Fitting/Device (Equivalent Fitting (Foot) Pf Friction Elev(Pe) q Equiv. Length) Fixed Pressure Losses, when Node 2 Elev 2 ;. Total Flow Actual ID Length Loss Per Unit applicable, are added directly (Foot) (Q) (Foot) Total (ps Friction(Pf) to (Pt) and shown as a (Foot) negative value. 0.00 55.571 Hose Allowance At Source 46 494.90 Total(Pt) Route 1 202 29-1 5.6 1.52 1 (See 01-8 120 12.145 " Route 2..... Notes) Sprinkler, T(5'-O) 5-0 0.124366 0.289 9 28'-5 :' 19.52 1.0490 5'8 0.705 13.139 Total(Pt) Route 2 203 29'-1 5.6 19.55 1 (See 0'-8 120 12.189 "" Route 3""' Notes) Sprinkler, 5'-O 0.289 35 28'-5 19.55 1.0490 0.124779 T(5-0) 5'-8 0.707 35 28'-5 1% 9'-3 120 13.185 0.002213 37 28-5 4.55 1.3800 9 -3 0.020 37 28-5 19.57 1% 93 120 13.206 Flow (q) from Route 4 0.048392 9-3 0.448 38 28-5 24.12 1.3800 38 28'-5 19.90 1% (See 10601/2 120 13.653 Notes) Flow (q) from Route 8 12-0 0.289 14 27'-9 44.02 1.3800 0.147311 2E(3-0), P0(6-0) If :. 117-0% 17.240 31.182 Total(Pt) Route 3 204 29-1 5.6 19.57 1 (See 0-8 120 12.208 ''•'Route 4'•••• Notes) Sprinkler,- 5'-0 0.289 37 28'-5 19.57 1.0490 0.124963 T(5'-O) 68 0.708 13.206 Total(Pt) Route 4 205 29-1 5.6 19.62 1 (See 0-8 120 12.280 ••••• Route 5•"• Notes) Sprinkler 5-0 0.289 , 41 28-5 19.62 1.0490 0.125644 T(5-0) 5'-8 0.712 41 28-5 14.87 1V4 8'-9 120 13.281 Flow (q) from Route 17 0.093834 43 28-5 - 34.50 1.3800 8-9 0.821 43 28'-5 20.24 1% (See 9'5% 120 14.102 Notes) Flow (q) from Route 9 6-0 45 28'-5 54.74 1.3800 0.220413 T(6'-O) 15-51/2 3.409 © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.61.0 4 12/19/2017 12:51:56PM Page 3 Job Name: Drawing2 Remote Area Number: 4 Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly (Pf) and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) • Total Flow (Q) Actual ID Total (Foot) Friction(Pf)•to 45 28'-5 1% (See Notes) 08 120 17.511 P0(6-0) 6'-0 0.220413 0.289 49 27-9 54.74 1.3800 6-8 1.469 49 27-9 21/2 14'-0 120 19.270 0008314 51 27'-9 5474 27050 14'-0 0.116 51 27-9 54.97 1 2/2 14'-0 120 19.386 Flow (q) from Route 6 0030090 52 27'-9 10971 27050 14'-0 0.421 52 27-9 11.34 2% 14'-O 120 19.808 Flow (q) from Route 11 0.036094 56 27'-9 - 121.04 2.7050 14 0 0.505 56 27'-9 21/2 14'-0 120 20.313 0.022053 58 27'-9 92.74 2.7050 14 0 0.309 58 27'-9 1% (See Notes) ) 08 120 20.622 P0(6 0) 6'-0 0.065628 -0.289 60 28-5 28.44 1.3800 6-8 0.438 60 28'-5 1% (See Notes 150'0 120 20.770 (6-0) T(6-0), PO(6'-O) /18-0 0.065628 0.289 20 27-9 28.44 F13800 168'-0 11.025 32.085 Total(Pt) Route 5 206 29'-1 5.6 ____ 19.68 __________ 1 ________ (See Notes) / 08 120 12.346 •••••Route 6••••• Sprinkler, T(5-0) 5'-0 0.126269 0.289 63 28-5 - -.. - 19.68 ______ 1.0490 5'-8 0.716 63 28-5 15.00 1 ,'4 8-9 120 13.351 Flow (q) from Route 18 0.094735 67 28'-5 34.68 1.3800 8 0.829 67 28'5 - 20.29 1% (S 9.51/2 120 14.180 Flow (q) from Route 10 T(6-0) 0.222171 68 28'-5 54.97 1.3800 15-5% 3.436 68 28-5 11% (See Notes) 0'8 120 17.616 PO(6'-O) 6'-0 0.222171 0.289 51 27-9 54.97 1.3800 F 6-8 1.481 1&©M.E.P.CAD, Inc. Fjj AutoSPRlNK®12v12.0.61.O 4 12/19/2017 12:51:56PM Page 4 Job Name: Drawing2 Remote Area Number: 4 Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step Nominal ID Fittings & Devices Equiv. Length (Foot) Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length). Fixed Pressure Losses, when are added directly to (Pf) and shown as a negative value. Fitting (Foot) . Loss Per Unit Elev(Pe) Node 2 Elev 2 (Foot) .. Total Flow Pf ction Actual ID Total (Foot) (psi) applicable, Friction(Pf) 19.386 Total(Pt) Route 6 207 29'-1 5.6 19.86 1 (See Notes) 0'-8 120' 12.571 ••••Route7•••• Sprinkler, T(5'-O) 5-0 0.128393 0.289 11 28-5 19.86 1.0490 68 0.728 13.588 Total(Pt) Route 7 208 29-1 5.6 19.90 1 (See Notes) 0-8 120 12.633 ••••• Route 8••• Sprinkler, T(5'-O) 5-0 0.128981 0.289 38 28'-5 19.90 1.0490 5'-8 0.731 13.653 Total(Pt) Route 8 210 29'-1 5.6 20.24 1 (See Notes) 0'-8 120 13.060 "" Route 9"" Sprinkler, T(5'O) 5-0 0.133002 0.289 43 28'-5 20.24 1.0490 5'-8 0.754 14.102 Total(Pt) Route 9 211 29-1 5.6 20.29 1 (See Notes) 0-8 120 13.133 •••" Route l0•'''• Sprinkler, T(5'-O) 5-0 0.133695 0.289 67 28'-5 20.29 1.0490 5'-8 0.758 14.180 Total(Pt) Route 10 212 29-1 5.6 23.55 1 (See Notes) 0-8 120 17.678 ••'•' Route 11 Sprinkler, T(5 0) 5-0 0.175993 0.289 70 28'-5 23.55 1.0490 5--8 0.997 70 28-5 11/4 (See Notes) 33'7% 120 18.964 T(6 0) 6-0 0011974 72 28'-5 1134 13800 39 71/2 0.475 72 28'-5 1% (See Notes) 01 8 120 19.439 P0(6 0) 6-0 0011974 0.289 52 27'-9 1134 13800 6 8 0080 19.808 Total(Pt) Route 11 213 29'-1 5.6 23.63 1 (See Notes) 0-8 120 17.799 ••••• Route 12•••• Sprinkler, T(5 0) 5-0 0.177105 0.289 74 28'-5 - 23.63 1.0490 6-8 1.004 74 28'-5 12.21 11/4 (See Notes) 107'11/2 120 19.091 Flow (q) from Route 19 T(6-0), P0(6-0) 120 0.100668 0.289 18 27-9 35.83 1.3800 119-1% 11.991 , © M.E.P.CAD, Inc. rij AutoSPRINK® 12 02.0.61.0 4 12/19/2017 12:51:56PM Page 5 Job Name: Drawing2 - Remote Area Number: 4 Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fittings & Devices Equiv. Length Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P0 and shown as a negative value. Fitting (Foot) Pf Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) . i Total Flow Actual ID Total (Foot) Friction(Pt) 31.371 Total(Pt) Route 12 76 -1-6 250.00 6 (See Notes'i / 4'-6 • 140 50.347 '••• Route 13•.... Hydrant, E(23-1%) 23-1% 0.001640 1.951 78 -6-0 250.00 6.3400 27'-7% 0.045 78 -6'-0 6 (See Notes) 22'11% 150 52.343 PO(16'-lO%) 16101/4 0.004818 33 -6-0 250.00 4.9500 39-10 0.192 52.535 Total(Pt) Route 13 58 27-9 21/2 9111,/2 120 20.622 ••••• Route 14• 0011202 44 27'-9 6431 27050 11% 0112 44 27-9 21/2 4'-O% 120 20.733 0002564 80 27'-9 2898 27050 4 0% 0.010 80 27-9 1% (See Notes) 0'8 120 20.744 P0(6 0) 6-0 0067978 -0.289 81 28'-5 - - --. 2898 13800 6 8 0.453 81 28-5 1% (See Notes) 1500 120 20.908 T(6 0) T(6-0), P0(6-0) 18'-0 0.067978 0.289 22 27-9 28.98 1.3800 168'-0 11.420 32.617 Total(Pt) Route 14 44 27-9 1% (See Notes) 01 8 120 20.733 " Route 15 • P0(6 -0) 6'-0 0.098042 -0.289 82 28'-5 -,' 35.33 1.3800 6'-8 0.654 82 28-5 11/2 (See Notes ' 251'93h 120 21.098 E(4 -0) 21(8'-O), E(4'-O) 24-0 0.032793 0.000 83 28'-5 -. 35.33 1.7280 275-9% 9.045 83 28'-5 1% (See Notes) 0'8 120 30.142 PO(6'-O) 6'-0 0.098042 0.289 84 27'-9 . . 35.33 1.3800 6'-8 0.654 84 27-9 3 10'-5 120 31.085 - 0001336 12 27'-9 3533 33340 10 0.014 lk,©M.E.P.CAD, Inc. AutoSPRINK®12v12.O.61.O 4 12/19/2017 12:51:56PM Page 6 Job Name: Drawing2 Remote Area Number: O fl Date: 12/19/2017 Pipe Information Node 1 Elev 1 (Foot) K-Factor Flow added this step (q) Nominal ID Fillings & Devices Equiv. Length Length (Foot) C Factor Total(Pt) Notes Fitting/Device (Equivalent Length) Fixed Pressure Losses, when applicable, are added directly to (P0 and shown as a negative value. Fitting (Foot) Pt Friction Loss Per Unit (psi) Elev(Pe) Node 2 Elev 2 (Foot) L Total Flow Actual ID Total 00) Fructuon(PO 31.099 Total(Pt) Route 15 56 27'-9 1¼ (See Notes) 0'8 120 20.313 •••'• Route 16•••.. P0(6 -0) 0.065047 85 28'-5 28.30 1.3800 6 8 0.434 85 28-5 11/4 (See Notes) 150'0 120 20.457 T(6 -0) T(6 0) P0(6 0) 181-0 0.065047 0.289 19 27'-9 28 30 1 3800 168 0 10 928 31.674 Total(Pt) Route 16 8 28-5 11/4 8'-3 120 13.118 '•••.Route17••••• 0019789 41 285 1487 13800 83 0.163 13.281 Total(Pt) Route 17 35 28'-5 1¼ 8'-3 120 13.185 •••" Route 18••••• 0.020100 63 28'-5 15.00 1.3800 8 0.166 13.351 Total(Pt) Route 18 70 28-5 9'-3 120 18.964 "•• Route 19••••• 0 013734 74 28'-5 12.21 1.3800 0.127 19.091 Total(Pt) Route 19 , © M.E.P.CAD, Inc. AutoSPRINK® 12 02.0.61.0 4 12/19/2017 12:51:56PM Page 7 Job Name: Drawing2 Remote Area Number: 4 è Date: 12/19/2017 iLen itf ji / Actual Inside Diameter 4.87 = F Schedule 40 Steel Pipe Inside Diameter) Factor Value Of C 100 130 140 150 Multiplying Factor 0.713 1.16 1.33 1.51 Effiffliffi ALV Alarm Valve AngV Angle Valve b Bushing BalV Ball Valve BFP Backflow, Preventer BV Butterfly Valve C Cross Flow Turn 90° cplg Coupling Cr Cross Run CV Check Valve DelV Deluge Valve DPV Dry Pipe Valve E 90° Elbow EE 45° Elbow Eel 11 %° Elbow Ee2 22W Elbow f Flow Device fd Flex Drop FDC Fire Department Connectk fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap f,© M.E.P.CAD, Inc. @JR AutoSPRlNK® 12 v1 2.0.61.0 4 12/19/2017 12:51:56PM Page 8 f fc- ~p t-+ , 0~k3 Page 1 of 6 MICROFAST® QUICK N IF(II1G l:II[.1u.7M RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in Approval Charts. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class 2020 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. [ WARNING: cancer and Reproductive Harm-//i\www.P65Warnngs.ca.gov TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Nominal K-Factor: 5.6 U.S. (80.6 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Overall Length: 2-3/4' (68 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring - Exposed, Screw and Pip cap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 by first adding the appropriate suffix for the sprin- kler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F / 57°C = A, 155°F / 68°C = B, 175°F /79°C = D, 200°F / 93°C = E, and 286°F / 141 °C = G For example, sprinkler 12997 with a Brass finish and a 155 °F / 68 °C temperature rating = Part No. 12997AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017). Wrench for recessed and/or wax coated sprinklers: Part No. 13655W/B** (available since 2006) *A 11z ratchet is required (not available from Viking). Form No. F_060914 19.02.21 Rev 19.1 Replaces form F_060914 Rev. 17.1.P65 (Removed F-i Escutcheon.) Page 2 of 6 MICROFAST® QUICK 'r RESPONSE HORIZONTAL I IF(II1GJ SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive fusible link disengages, the pip cap and spring are released, and the waterway is opened. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is available through a network of domestic and interna- tional distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Figure 1: Standard Sprinkler Wrench 21475M1B Form No. F_060914 19.02.21 Rev 19.1 Page 3 of 6 MICROFAST® QUICK 41KJ:N7G I*l:II[u'Lw RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 11! •TEMPERATURE RAT Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature' Bulb Color U o or Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and ENT Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with Polyester, and ENT coatings. Step 1: Carefully slide the wrench sideways around the deflector, ensuring en- gagement with the sprinkler wrench flats. Sprinkler wrench 13655W/B** must be used for installing wax coated sprinklers. ** A 1/2" ratchet is required (not available from Viking) Step 2: Carefully press the wrench onto the sprinkler wrench flats. Figure 2: Wrench 13655W/B for Recessed Sprinklers Form No. F 060914 19.02.21 Rev 19.1 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 1(UL) Temperature KEY I I Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 Finish For Light or Ordinary Hazard Occupancies AIX*- Escutcheon (itapplicable)I Maximum 175 PSI (12 Bar) WWP Deflector must be located 4" to 12" (102 mm to 305 mm) below the ceiling. Base Part Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals3 Number' SIN Style _____ ______ _____ ________ ______ (Refer also to Design Criteria on page 43x.) NPT BSP U.S. metric2 Inches mm cULus4 LPCB 12997 VK305 HSW 1/2" 15 mm 5.6 80.6 2-11/16 68 A1W, 61X, -- C2W, D2Z -- -- 19782 VK305 HSW 1/2" -- 5.6 80.6 2-11/16 68 - - -- E3 IIDIIProduct Limited TAvailability Local Viking Office) 12121 VK305 HSW 1/2' 15mm 5.6 80.6 1-11/16 68 A1W, B1X, C2W,D2Z - Approved Temperature Ratings A - 135 °F (57 CC), 155 °F (68 °C), 175 °F (79 °C), 200 F (93 °C), and 286 °F Approved Finishes Approved Escutcheons (141 C) W - Installed with standard surface-mounted escutcheons B - 135 °F (57 °C), 155 °F (68 CC), 175 °F 1 - Brass, Chrome, White Poly-ester -', X - Installed with standard surface-mounted escutcheons or (79 °C), and 200 °F (93 °C) and Black Polyester' .6 recessed with the Viking Micromatic® Model E-1, E-2, or C - 155 °F (68 °C), 175 °F (79 °C), 200 °F 2 - ENT5 G-1 Recessed Escutcheon (93 °C), and 286 F (141 °C) 3 - Chrome Z - Installed with standard surface-mounted escutcheons or D - 155 °F (68 °C), 175 °F (79 °C), and 200 recessed with the Viking Micromatic Model E-1 ¶ (93 °C) E - 155 °F (68 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. DESIGN CRITERIA - UL (Also refer to Approval Chart 1.) cULus Listing Requirements: Quick Response Horizontal Sprinkler VK305 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. Locate with the deflector 4" to 12 (102 mm to 305 mm) below the ceiling. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Align the top of the deflector parallel with the ceiling. Locate no less than 4" (102 mm) from end walls. Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_060914 19.02.21 Rev 19.1 Page 5 of 6 MICROFAST® QUICK N41KJN7G14 ls:lIEu.7M RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY Quick Response Sidewall Sprinklers Finish AIXI— Escutcheon (if applicable) Maximum 175 PSI WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals34 Number' SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches mm 12997 VK305 1/2" 1 15 mm 5.6 80.6 2-11/16 68 A1Y, B1X NOTICE)j7j I:j7. • Limited Availability ('f7ThTILocal !IIW17I.Jllt 12121 1 VK305 1/2" 15 mm 1 5.6 80.6 2-11/16 1 68 AIY, SiX Approved Temperature Ratings Approved Escutcheons A- 135 °F (57 °C), 155 °F (68 °C), 175 IfliS Approved Finishes x - Installed with standard surface-mounted escutcheons or recessed °F °C), SC), (79 200 F (93 and 286 with the Viking Micromatic® Model F-i F-2, E-3, or G-1 Recessed °F (141 °C) 1 - Brass Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 Y - Installed with standard surface-mounted escutcheons °F (79 °C), and 200 °F (93 °C) Footnotes 'Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Viking vertical sidewall sprinklers may be installed pendent or upright. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Horizontal Sidewall Sprinkler VK305 is FM Approved as a quick response Non-Storage sidewall sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_060914 19.02.21 Rev 19.1 Page 6 of 6 lvii i.jrio i tv WuII..,r RESPONSE HORIZONTAL N41KJW*j TECHNICAL DATA SIDEWALL SPRINKLER vwnc iw'c rn The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 2-3/4" (68 mm) H 2-7/16" (62 mm) Wall Opening Size: Installed with a Standard 2-5/16" (58.7 mm) minimum 1/8" Surface-Mounted 2-1/2" (63.5 mm) maximum Escutcheon 3: Sidewall Sprinkler Dimensions with a Standard Escutcheon Minimum I Minimum 1-5/8" 1-3/4" f (41 mm) (45 (45 1__ 2-1/8" (54 mm) ___ 1 (54 mm) 2-1/4" 2-5/8" (57 No mm) (67 mm) Maximum Maximum Wall Opening Size: Installed with the Installed with the 2-5/16" (58.7 mm) minimum Micromatic Model El Threaded Model E-2 2-1/2" (63.5 mm) maximum Recessed Escutcheon Recessed Escutcheon Figure 4: Sidewall Sprinkler VK305 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_060914 19.02.21 Rev 19.1 Replaces form F_060914 Rev. 17.1.P65 (Removed F-i Escutcheon.) S Page 1 of 6 N41KJW*j MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatingscan be used in decorative applications where colors aredesired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class Series 2000 EJ VdS Approved: Certificates G414009 and G414010 LPCB Approved (E CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B. 175 °F (79 C) = D, 200 °F (93 C) = E. 286 °F (141 C) = G For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories (Also refer to the current Viking price list.) Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 6 \,J II(IIS1G® MICROFAST@ QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: Standard Wrench: Part No. 21475M/13 (available since 2017). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A %" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap F~ ME, — Figure 1: Standard Sprinkler Wrench 21475M1B Form No. F_033314 17.10.05 Rev 17.2 Page 3 of 6 \J II(IF1G® - MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient ' Bulb Color u Classification Temperature Rating' Ceiling Temperature' Ordinary 135 °F (57 C) 100 °F (38 C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) 4* Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F033314 17.10.05 Rev 17.2 Page 4 of 6 MICROFAST® QUICK 'J I KI IiIG SPRINKLER VK302 (K5.6) RESPONSE PENDENT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) The Viking Microfast Quick Response c-- Temperature KEY Pendent Sprinkler VK302 I. Finish A&' Escutcheon (i applicable) Maximum 175 PSI(12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals3 Part SIN ye I K-Factor Length (Refer also to Design criteria.) Number' NPT BSP U.S. metric' Inches mm cULus' VdS LPCB (E 7 12979 VK302 Pendent 1/2" 1 15 mm 5.6 60.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, C1Y -- 19780 VK302 Pendent 1/2" -- 5.6 80.6 2-1/4 58 -- -- -- -- -- D3 21354 VK302 Pendent -- 15mm 5.6 80.6 2-1/4 58 -- -- -- -- -- 03 - uct Below - Limited Availability (Contact Local Viking Office) 06662B VK302 Pendent 1 1/2" 15 mm 1 5.6 1 80.6 1 2-1/4 58 A1Z, B1Y, D2, C2X -- -- -- -- 18021 VK302 Pendent 1 1/2" 15 mm1 5.6 1 80.6 1 2-1/4 58 AiX, B1Y Al I AiX, B1Y I Dlx, Cly8l D1X, C1Y9 Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 OF (57 °C), 155 OF (68 °C), 175 OF 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 OF (93 °C), 286 OF (141 °C) Polyester56, Black Polyes- Viking Micromatic Model E-1 Recessed Escutcheon B - 135 OF (57 "C) 155 OF (68 °C), 175 OF ter" Y - Standard surface-mounted escutcheon or the (79 °C), and 200 OF (93 °C) 2 - ENT5 Viking Microfast Model F-i Adjustable Escutcheon, or recessed with the Viking Micro- C -155°F (68 °C), 175°F (79 °C), and 3-Chrome mati& Model E-1, E-2, or E-3 Recessed Escutcheon 200 OF (93 °C) Z - Standard surface-mounted escutcheon or the 0- 155 OF (68 °C), 175 OF (79 °C), 200°F Viking Microfast Model F-i Adjustable Escutcheon (93 °C), 286 OF (141 °C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. "Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA - UL (Also refer to Approval Chart I above.) cULus Listing Requirements: The Viking MicrofastO Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 5 of 6 4 MICROFAST® QUICK ,J II(II1G RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY The Viking Microfase Quick Response Finish Pendent Sprinkler VK302 AIX4— Escutcheon (it applicable) Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals' Number' SIN Style (Refer also to Design Criteria.) NPT BSP U.S. metric2 Inches 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 1 58 1 A1Z, B1Y, D2X, C2 1.)il.E - ProductI:1P'l Limited 1' 7llIy (Contact Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1 1/2" 15 mm 5.6 80.6 21/4 1 58 1 A1Z, B1Y Approved Escutcheons Approved Temperature Ratings x - Standard surface-mounted escutcheon or the A - 135°F (57 °C), 155°F (68 °C), 175 °F (79 °C), 200 °F Viking Micromatic' Model E-i Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon B - 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), and 1- Brass, Chrome, White Polyester', Y - Standard surface-mounted escutcheon or the 200 °F (93 °C) and Black Polyester' Viking Microfastn Model F-i Adjustable Escutcheon, C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 or recessed with the Viking MicromaticE Model E-i °F (141 °C) or E-2 Recessed Escutcheon D - 155°F (68 °C), 175°F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon or the Viking Microfast Model F-i Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM ArovaI Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 6 of 6 MICROFAST® QUICK II(II1G ® J i.iIII1U.7M RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 2-5/16" (59 mm) minimum (15 mm) - 2-1/2" (64 mm) maximum NPT\ 21 _____ (57 mm) i j(;m) Installed with a standard Installed with a Microfast Note: At maximum, adapter 1/8" surface-mounted Model F-I Adjustable is exposed 112" (13 mm) escutcheon Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon O Ceiling Opening Size: - 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum I.2II8" J :' ........._........._J: (54 mm) 1-3/4" (45 mm) Max. W) I 1-1/8" T (29 mm) 2" Min. (Sqn;fl) 1-1/8" (29 mm) Mm. Installed with a Installed with a Model Model E-I Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Horizontal Sidewall Vertical Sidewall U/P S February 3, 2014 Sprinkler 43u 'J II(JI1G° l.l:IIru.7M QUICK RESPONSE SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Quick Response Vertical and Horizontal Sidewall Sprinklers are small thermo- sensitive glass bulb spray sprinklers available with various finishes and temperature ratings to meet design requirements. The special Polyester, PTFE, and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in Approval Charts. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 Refer to Approval Chart 1 and Design Criteria on pages 43w-x for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 43y for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2004. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Deflector: U.S.A. Patent No. 4,296,816 Thread Size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Viking Technical Data may be found on Material Standards: The Viking Corporation's Web site at Frame Casting: Brass UNS-C84400 or QM Brass http:I/www.vikinggroupinc.com. Deflector: Copper UNS-C19500 for horizontal sidewall sprinklers. Brass The Web site may include a more recent UNS-C2300 for vertical sidewall sprinklers, edition of this Technical Data Page. Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring - Exposed, Screw and Pip cap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/\N, Black Polyester = M-/B, Black PTFE = N, and ENT = JN Temperature Suffix: 135°F / 68°C = A, 155°F / 68°C = B, 175°F / 79°C = D, 200°F / 93°C = F, and 286°F / 141 °C = G For example, sprinkler 12997 with a Brass finish and a 155 °F / 68 °C temperature rating = Part No. 12997AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Form No. F_060504 Replaces page 43u-z, dated March 23, 2012. (Added ENT Finish) S Sprinkler 43v February 3, 2014 ® QUICK RESPONSE pJ II(II1G l:II[.u.7M SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for recessed sprinklers with protective shields: Part No. 13655W/B** (available since 2003) **A W ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Quick Response Horizontal and Vertical Sidewall Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributoror contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Wrench Fl a tShietd Sprinkler otl 10896 Figure 1: Standard Sprinkler Wrench 10896W/B Protective Sprinkler Shield Sprinkler Wrench 13655W/B* for Recessed Horizontal Sidewall Sprinklers Fit the wrench over the sprinkler and protective shield as shown. IlENote 1/2' ratchet is required. (Not available from Viking.) Figure 2: Wrench 13655W/B for Recessed Horizontal Sidewall Sprinklers S L February 3, 2014 Sprinkler 43w QUICK RESPONSE 'J I FJ l.1:IIE7M SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1:AVAILABLE SPRINKLERli'alJ; Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature Ordinary 135 OF (57 °C) 100 OF (38 °C) Orange Ordinary 155 °F(68 °C) 100 °F(38 °C) Red Intermediate 175 OF (79 °C) 150 OF (65 °C) Yellow Intermediate 200 OF (93 °C) 150 oF (65 °C) Green High 286 OF (141 °C) 225 OF (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, Black PTFE, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, Black PTFE, and ENT .Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with Polyester, PTFE, and ENT coatings. Approval Chart I (UL) Temperature KEY I Quick Response Sidewall Sprinklers Finish I For Light or Ordinary Hazard Occupancies I AIX4-Escutclleon (if applicable)I Maximum 175 PSI (12 Bar) WWP Deflector must be located 4" to 12" (102 mm to 305 mm) below the ceiling. Base Part Sprinkler Thread Size _______ Nominal K-Factor Overall Length Listings and Approvals3 Number' SIN Style _____ _________ ______ ______________ _____________________ ______ _________ (Refer also to Design criteria on page 43x.) ____________________________________ NPT BSP U.S. I metric2 Inches mm cULus4 I NYC I LPCB I I 12997 VK305 HSW 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y,B1X, I I C2W,D2Z 12983 VK306 vsw u/P 1/2" 15 mm 5.6 80.6 2-1/4 58 -- -- -- -- -- Approved Temperature Ratings Approved Escutcheons A - 135 OF (57 °C), 155 OF (68 °C), 175 W- Installed with standard surface-mounted escutcheons F (79 °C), 200 OF (93 °C), and 286 OF X - Installed with standard surface-mounted escutcheons or (141 C) Approved Finishes the Viking Microfast® Model F-i Adjustable Escutcheon, B - 135 OF (57 DC), 155 OF (68 °C), 175 OF - Brass, Chrome, White Poly-ester'.', or recessed with the Viking Micromatic® Model E-1, E-2, (79 °C), and 200 OF (93 °C) Black Polyester 5.6 and Black PTFE5 or G-i Recessed Escutcheon C - 155 OF (68 °C), 175 OF (79 °C), 200 OF 2 - ENT5 Y - Installed with standard surface-mounted escutcheons or (93 °C), and 286 OF (141 °C) the Viking Microfast5 Model F-i Adjustable Escutcheon D - 155 OF (68 °C), 175 OF (79 °C), and 200 Z - Installed with standard surface-mounted escutcheons or OF (93 °C) recessed with the Viking Micromatic Model E-i Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. Sprinkler 43x February 3, 2014 'I II(IF16i® l:II[.1u'YM QUICK RESPONSE SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESIGN CRITERIA - UL (Also refer to Approval Chart 1 on page 43w.) cULus Listing Requirements: Quick Response Horizontal Sprinkler VK305 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. Locate with the deflector 4" to 12" (102 mm to 305 mm) below the ceiling. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Align the top of the deflector parallel with the ceiling. Locate no less than 4" (102 mm) from end walls. Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Approval Chart 2 (FM) Temperature KEY Quick Response Sidewall Sprinklers Finish Al X 4— Escutcheon (if applicable) Maximum 175 PSI WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals34 Number' SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric' Inches mm 12997 VK305 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y, B1X 12983 VK306 1/2" 15 mm 5.6 80.6 2-1/4 58 A2Z Approved Temperature Ratings Approved Escutcheons X - Installed with standard surface-mounted escutcheons or the Viking A- 135°F (57 °C), 155°F (68 "C), 175 Approved Finishes Microfast Model F-i Adjustable Escutcheon, or recessed with the °F (79 °C), 200 °F (93 °C), and 286 1 - Brass Viking Micromatic Model E-1, E-2, or G-1 Recessed Escutcheon °F (141 °C) 2 - Brass and Chrome Y - Installed with standard surface-mounted escutcheons or the Viking 8 - 135 °F (57 °C), 155 "F (68 °C), 175 Microfast Model F-i Adjustable Escutcheon °F (79 °C), and 200 °F (93 °C) Z - Installed with standard surface-mounted escutcheons only. Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4 Viking vertical sidewall sprinklers may be installed pendent or upright. February 3, 2014 Sprinkler 43y "\J I I(IF1G ® l:II[.q•.rM QUICK RESPONSE SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Horizontal Sidewall Sprinklers VK305 and Vertical Sidewall Sprinkler VK306 are FM Approved as a quick response Non-Storage sidewall sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Volt Opening Size: 2-5/16' (57.2 mm) minimum 2-1/2' (63.5 rim) maximum 2-1/16 (52.4 mm) Minimum E... 2-7/16 2-11/16' (61.9 mm) (25mm 1/2 (15 mm) NPT 2-5/8' (66.7 mm) Installed with the Maximum 1/8' (3.1 mm) standard Installed with the MicroFast surface -mounted escutcheon Model F-i Adjustable Escutcheon Figure 3: Sidewall Sprinkler VK305 Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Maximum Recess: 1/2' (12.7 mm) Adjustable Adapter Ring Depth: 1-1/16's (27 mm) Sprinkler 43z February 3, 2014 tJ II(II%IG® l:II[.11.rM QUICK RESPONSE SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Wall Opening Size: 1-5/8 I 2-5/16 (57.2 mm) rnifllmUm 1-3/4 (41.3 ) 2-1/2 (635 mm) maximum Minimum I Minimum P 2-1/4' 2-5/8' (57,2 mm) (67 mm) Maximum Maximum (54 mm) -- I 2-1/4' (58 mm) 1/2' (15 rim) NPT Installed with the Micromatic Installed with the Threaded Vertical Sidewall Model E-1 Recessed Escutcheon Model E-2 Recessed Escutcheon Sprinkler VK306 Figure 4: Sidewall Sprinkler VK305 Dimensions with the Model E-1 and E-2 Recessed Escutcheons and Vertical Sidewall Dimensions VaIl Opening Size with the Model G-1 Escutcheon: -- r 2-5/8' (66 mm) minimum / (3.2 mm) 3-3/4' (95 mm) maximum Adjustable Outer Cup (66 mm)(1O2mm) 1-1/16' (27 mm) Figure 5: Sidewall Sprinkler VK305 Dimensions with the Model G-1 Recessed Escutcheons Form No. F_060504 Replaces page 43u-z, dated March 23, 2012. (Added ENT Finish) The Cost Effective. Replacement for Schedule 10 Realizing the growing need of fire protection systems systems with a working pressure of 300 psi or less. in commercial and residential construction, Bull Please check with appropriate sources for up-to-date Moose Tube has added Eddy Flow to its . listings and approval information. comprehensive line of sprinkler pipe products. Eddy Flow is a specially engineered replacement for schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL listed (for U.S. and Canada) for roll grooving and welding for use in fire protection COMPARISON As an added benefit, it is more economical to use than schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's larger ID provides an opportunity for downsizing and further cost savings. OEM Mavm I Mao ma 11/4 111/2 1.660 11 1.530 1 442 - [i.o 38 1.98 1 too 1.900 1.728[ 1.682 1.610 344l 1.00 2 2.375 2.157 2.067 [2.78 tOO 1.00 121/2 2.875 F 2.705 2.635 2.469 1.66 3F 3.500 3.334 3.260 3.068 1.00 1.00 ____ 4.5OO4.3ioj[_4.260 1 4.026j[ i.pp._j —1—.00--- * Corrosion Resistance Ratio BENEFITS Dual Certified to ASTM A135 and A795. FM Approved for roll grooved, and welded, and plain-end application in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. UL Listed (for US and Canada) and FM Approved for use with Victaulic' FIT Fittings in plain end applications. Lightweight - saves shipping costs, and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Floor stock available in various lengths produced in Casa Grande (AZ), Gerald (MO), and Masury (OH). Also can be ordered in custom lengths.. Can be used for wet and dry* systems. * Eddy Flow can be hot dipped galvanized to meet FM'S requirement for dry systems. PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, C L us @ A Chesterfield, MO 63017 contact your salesperson today at BULL MOOSE TUBE COMPANY (800) 325-4467 (800) 325-4467 or (636) 537-2600 USED /nMMT, FAX: (636) 537-2645 in the USA, or from Canada ______ www.bullmoosetube.com call (800) 882-4666 AcRcompany e-mail:saIes@buIlmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer of quality pipe products. Our Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube made the decision to have them approved and listed for your peace of mind. Our Sch. 10 and Sch. 40 have been through the same rigorous testing as our other fine pipe products. Schedule 10 Pipe Bull Moose Tube's Sch. 10 and Sch. 40 pipes are made to ASTM A135 and ASTM A795. These products are typically supplied with our protective coating but can be supplied without the coating so they can be hot-dip galvanized to meet FM requirements for use in dry systems in accordance with the zinc coating specifications of ASTM A795 or ASTM A53. All Schedule 10 and Schedule 40 pipe has a pressure rating of 300 PSI. I ir JJ@ii II Pmom_II_' _I 1 1.315 1.097 1.41 lbs/ft 91 11/4 [__1.66p 1.442 1.81 lbs/ft 61 1 1/2 1.900 1.682 1 2.09 lbs/ft 61 [2 2.375 2.157 2.64 lbs/ft 37 21/2 2.875 2.635 3.53 lbs/ft 30 [3 3.500 3.260 - 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft - 19 Schedule 40 Pipe I_I mmamsm I Basm ,I mom P MM P 1 1.315 1.049 1.68 lbs/ft 70----- [__1 6-60 1.380 2.27 lbs/ft 51 [11/2 1.900 1.610 2721, [ 44 2.375 2.067 3.66 lbs/ft 30 [21/2 2.875 2.468 5.80 lbs/ft 30 [3 3.500 3.068 7.58 lbs/ft 4 4.500 [. 4.026 10.80 lbs/ft L 19 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. - ----;, - 1819 Clarkson Road For additional information, u - Chesterfield, MO 63017 A6 '800' 325-4467 contact your salesperson C US (.,) I I BULL. MOOSE TUBE COMPANY / FAX: (636) 537-2645 t d t '800' 325-4467 today a / or (636) 537-2600 in the USA, LISTED --- www.bullmoosetube.com ______ or from Canada FM ACROcompany e-mail: saIesbuIImoosetube.com call (800) 882-4666 APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 12/09 . S Sta4_$..e p & Supply, Inc. THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS. ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES. TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE, AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM. SCHEDULE 10 -- Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal O.D. I.D. Weight I Foot psi T. 1.315 1.097 1.410 700 1-1/4" 1.660 1.442 1.810 1200 1-1/2 1.900 1.682 2.090 1200 2.375 2.157 2.640 2300 2-1/2" 2.875 2.635 3.530 2500 3.500 3.260 4.340 1290 4.500 4.260 5.620 1000 5.563 5.295 7.780 1010 6.625 6.357 9.300 1020 8.625 8.249 1 16.960 780 8" wall thickness is 0.158, not SCH10 or 0.148" wall thickness. COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. Chemical Requirements. Percent (Product) C Mn P I S I Other Specification Grade max max max max ASTM A53 A 0.250 0.950 0.05 0.045 - 1 Residual elements max: Cu-0.40, Ni-0.40, Cr-0.40, Mo-0.15 and V-OS. These live elements combined shall not exceed 1%. Mechanical Properties-Tensile Requirements Strength-psi. Yield Tensile Specification Grade Min Max Min Max ASTM A53 A 30,000 - 48,000 - NOTE: Elongation requirements vary with nominal area of test specimen and specified minimum tensile strength of the steel grade. 9615 S. Norwalk Blvd., Santo Fe Springs, CA 90670 . (562) 695-5555 • FAX: (562) 692-1054 . www.statepipe.com . S c2z J7 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 100 REVERSIBLE BEAM CLAMP 3/4" MOUTH SIZE - 3/8' and 1/2" rod. MATERIAL - Ductile iron. FINISH - Plain, E.G. and H.D.G. LISTINGS - c US 203-EX 2551 Approval guide - Pipe Hangers FUNCTION - Hanger assembly attachment to steel flange with thickness of less than 3/4". INSTALLATION - Per NFPA 13 with set screw up or down. Torque - 3/8= 60 inchlbs. or 1/2= 125 inch lbs. In the absence of a torque wrench, engage set bolt finger tight then additionally tighten 1/3 turn. FEATURES * Listings allow installation with set screw up or down - see drawings. * Maintains CONSTANT HANGER CENTER-LINE, with set screw up or down. * Flat throat back to prevent twisting on flange during installation. ORDERING - Part #, rod size and finish. 1/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 162 UNIVERSAL RESTRAINING STRAP Nut optional, if insufficient rod dimension rVA SIZE- One size fits both 3/8" and 1/2" rod or set screw. Available lengths 4' and longer. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - cus 203-EX 2551 PATENT - No. 5,897,088 FUNCTION - To enhance hanger attachment in areas subject to Earthquakes. INSTALLATION - Install tight to structure and component parts Minimum return on strap: 1" L-dimension is measured from hanger rod center to the strap end. FEATURES * Fast installation for new construction or retrofit. * Requires no hanger disassembly to install. IMPORTANT NOTE: "No Nut Is Required" When installed tight to structure and component parts. (See drawings provided) ORDERING - Part # and L-dimension. 1/08 The purlin lip is not capable of supporting NFPA 13 fire sprinkler pipe at 1(wt.) +250 lbs mm. When manufacturers specify 200 lbs. max. 5's . 0 1;?0§'o P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 551 REVOLVER THREADED BRACKET SIZE - 3/8" rod. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and S.S. LISTING/APPROVAL - cus 203 - EX 2551 PATENT - No. 6,568,642 FUNCTION - Listed to support max. 4" Steel, CPVC or Copper pipe. Listed hanger component per NFPA 13. INSTALLATION - per NFPA 13. Space by pipe type. Install on vertical mounting surface of wood, concrete or steel. Center hole accepts 3/8" and 1/2" NFPA 13 fasteners. ADDITIONAL UL LISTED FASTENERS PER NFPA 13 FOR STEEL PIPE LOADS -SEE TABLES.. 000 1 2.0312 tø 1 3/8 11.250 FEATURES * Universal fastener array for enhanced mounting. * Double fastener installation allows: Vertical - Hangs plumb from first fastener. Stops wood splitting along the grain. Horizontal - When vertical space is limited. * Radius -Tapped orifice: Aligns rod for easy thread engagement and eliminates structural deficiencies associated with rod inserts. * No speed/pal nuts required. ORDERING - Part # and finish. UL Fasteners Locations 1@ BorE 3@ A-C-E ® ® 2@ B-E 3@ B-D-F ® 2@ A-C 4@ A-C-D-F Wood — No Pre Drill Mm. Mm. Max. Fastener Qty Pipe Steel - 114 or #14 Tek Min. Mm. Max. Thickness Qty. Pipe Steel - #10 SMS or #905 Mm. Mm. Max. Thickness Qty Pipe 1/4x1 '/2 Lag I 2 14 GA. 1 3 18 GA. I 2',t 24 24 2 3 3 4 #I4x I V2 SMS I 2 16 GA. 1 2 V2 2 4 2 4 20 GA. 2 3 44 #I6x2DS 2 2 18 GA. I 2Y2 3 4 2 3 22 GA. 3 3 Wood - Thru 5/8" Gyp. 20 GA. * 1 2 I/4x2 Lag I 2 2 4 @BONLY 2 3 3 4 DS Drive Scr,v #14 2 SMS I 2 SMS = Sh,,I Meol Screw 2 4 22 GA. 3 2 /2 .agt.gBoIl Gyp=Gyp— 8ord 1/09 M5iII 1O11A TAN D RA I N Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve cLus FM 3,/411 111 11/411 11/211 211 APPROVED (Tr..J j Tri:EST 41 PUSH -_ __ 2* l mitc•- __- - WI lic MOO(L 'The AGF Manufacturing Inc. Model 1011 TESTANDRAIN® matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system, with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. 'The Model 101 1A complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). 'The Model 101 1A TESTANDRAIN® is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. 'Available in a full range of sizes from 3/4" to 2' NPT and BSPT, with all specifiable orifice sizes %" (2.8K), 7A6" (4.2K), ½" (5.6K), 17/32" (8.0K), 5/s" (11.2K, ELO), 3/4" (14.0K, ESFR), and K25 as required by NFPA 13, 2007 Edi- tion (see reverse). The included UL/FM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. 'Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-piping outlet. 'Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. 'A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. 'Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1) stem packing, and (1) stem washer ae avail- able for all TESTANDRAIN® valves. Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. \ LL1II Wmaim TESTANDRAIN is a registered trademark of AOF Manufacturing Inc. CS1011A 10/09 DIMENSIONS MODEL 1011 - FRONT VIEW Orifice Size Available: /8", /16", ½", 17/32*, ELO (5/s)*, ESFR (3/4*)* & K25** SIZE A B C D E F G H 3/," 7A6" 11/2 23A6" 35/8 33/8 113/16" 4A6" 63/8 (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 79A" 1½" 23A6" 35/8 33/8' 11A6" 4A6" 63/8" (191 mm) 1 (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4 715A6" 111A6" 29/16" 41/4 35/8" 115A6" 59/16" 51/2 (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1½" 815A6" 113A6 31/4 51/16" 3/8" 25/8 81/4 107/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2" 815A6" 113A6" 31/4" 51A6" 3/8" 25/8" 81/4" 107/8 ' (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) * Available on 11/4" to 2" size units only ** Available on 1112" and 2" size units only THE MODEL 1011 PROVIDES ALL OF THE FOLLOWING... From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow... using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterf)ow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.1 7.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than /2" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve MODEL 1011 - PLAN VIEW MATERIALS Handle: Steel Stem: Rod Brass Ball: C.P. Brass Body: Bronze Valve Seat: Impregnated Teflon® Indicator Plate: Steel Relief Valve: Bronze Bypass Fittings: Brass Bypass Tubing: Nylobraid APPROVALS UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM Mt A;' 'k I AGF Manufacturing Inc. I I 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 I Fax: 610-240-4906 I www.testandrain.com Job Name: Architect: Engineer: Contractor: Can be installed on bar joists or 1-beams Thumb spring retainer allows for ease of positioning Snap-off bolt head helps enable easy installation and inspection of seismic sway braces No assembly required No loose parts Meets NFPA-13 requirements for seismic sway bracing Material: Steel C@US <8> OSHPD APPROVED Part Number I Finish Flange Thickness FT I A I B I c I CSBBARJEG Electrogalvanized 1/4 - 1/2 I 2' 3" I 21/2" CSBBARJHD Rot-Dip Galvanized 1/4" - 1/2" 2" 3" 21/2" UL Loads Brace Direction to Structure Service Pipe Size Rating Parallel 1'- 10" 3,000 lb Perpendicular 1"- 12" 3,740 lb FM Loads Brace Direction to Structure I I Service Pipe Size Horizontal Capacity per Installation Angle from Vertical 30° - 44° I 450 - 590 60o - 740 I I 750 - 90° Parallel I N/A 1,410 lb I 2,110 lb 2,540 lb I 2,830 lb Perpendicular N/A 1,740 lb 1,710 lb 2.060 lb 2,300 lb PENTAIR FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association. Inc. UL. UR, cUL, cUR. cULus and cURus are registered certification marks of UL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative. Improper installation. misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2016 Pentair All rights reserved Pentair. CADDY, CADWELO, CRITEC, ERICO. ERIFLEX, ERITECI-I and LENTON are owned by Pentair or its global affiliates. All other trademarks are the properly of their respective owners. Pentair reserves the right to change specifications without prior notice. +PENTAIR The Quick Grip Lateral Brace, part of the CADDY line of fire sprinkler bracing systems from Pentair, is designed to help simplify installations when bracing service pipe for seismic or other catastrophic events. It features an innovative design for quick attachment of brace pipe to service pipe saving time and money. Easy two-step installation elminates extra trips between structure and service pipe Works with 1" and 1 1/4 (25 mm and 32 mm( brace pipes to reduce inventory Yellow tips provide a visual indicator that the bolts have been properly torqued Easy installation with an impact wrench from the bottom side of the clamp Meets NFPA-13 requirements for seismic sway bracing Material: Steel Finish: Electrogalvanized c@us ~'~ OSHPD APPROVED Part Number Pipe Size Height Width H W CS80G0250EG 2 1/2' 5 7/16" -57/8" 6 3/4" CS8000300EG 3" 6 1/8' - 6 1/2" 7 1/2" CSBQG0400EG 4' 7 1/8' -7 1/2" 8 3/4" CSB060600EG 6' 9 1/4" - 9 5/8" 113/4" CSBQG0800EG 8" 11 3/8" -11 13/16' 13 7/8" UL Loads Part Number Service Pipe Schedule Lateral 1" Brace Pipe 1 1/4" Brace Pipe CS8060250E6 . Dyna-Flow® 2.015 lb 2.015 lb 10 2,015 lb 2,015 lb 40 2,015 lb 2,015 lb CSB000300EG Dyna-Flow® 2,015 lb 2,015 lb 10 2,015 lb 2,015 lb 40 2,015 lb 2,015 lb CSB000400EG Dyna-Flow® 2.015 lb 2.015 lb 10 2,015 lb 2.015 lb 40 2,015 lb 2.015 lb cl +PENTAIR fl fl UL Loads Part Number Service Pipe Schedule Lateral 1" Brace Pipe 1 1/4" Brace Pipe C5B050600E6 Mega-Flow 2,015 Lb 2.015 Lb 10 2.015 Lb 2.015 Lb 40 2.015 lb 2,015 lb CS8060800EG 10 2.015 lb 2,015 lb 40 2,015 lb 2,015 lb FM Loads Part Number Service Pipe Schedule Lateral Horizontal Capacity per Installation Angle from Vertical 30° - 44° 45° - 59° 60° - 74° 75° - 90° LighLwaLL 1,410 lb 2.000 Lb 2,450 Lb 2.740 Lb CSBQG0250EG 10 1.410 Lb 2,000 lb 2,450 Lb 2,740 lb 40 1,410 Lb 2,000 Lb 2.450 Lb 2,740 Lb CSB060300EG Lightwatt 1.190 Lb 1,680 lb 2,060 Lb 2.300 Lb 10 1,190 Lb 1,680 Lb 2,060 Lb 2,300 lb 40 1,190 Lb 1,480 Lb 2,060 Lb 2.300 lb CS80G0400EG Lightwalt 1.190 Lb 1,680 Lb 2.060 lb 2,300 Lb 10 1.190 lb 1,680 Lb 2.060 lb 2.300 Lb 40 1,190 Lb 1.680 Lb 2,060 Lb 2,300 Lb CS60G0600EG LightwalL 870 Lb 1,230 Lb 1.510 Lb 1,690 Lb 10 870 Lb 1,230 Lb 1,510 Lb 1,690 Lb 40 970 Lb 1,370 Lb 1,680 Lb 1,870 lb CSBOG0800EG 0.188" lWatt Thickness) 790 Lb 1.110 Lb 1,360 Lb 1,520 lb 40 790 Lb 1.110 lb 1.360 Lb 1.520 Lb Dyna-Flow is a registered trademark of Allied Tube & Conduit Corporation. FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL, UR, cUL. cUR, cULus and cURus are registered certification marks of UL LLC. WARNING Pentair products shalt be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product mattunction, property damage, serious bodily injury and death and/or void your warranty. © 2016 Pentair ALL rights reserved Pentair, CADDY. CADWELD, CRLTEC. ERICO. ERIFLEX. ERLTECH and LENTDN are owned by Pentair or its global affiliates. Alt other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. P >' ENTAIR Use for both Lateral and longitudinal sway brace applications Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Slotted design grabs service pipe for added gripping strength Meets NFPA-13 requirements for seismic sway bracing xr~ L1J IF Material: Steel c®us K€ OSHPD APPROVEO Part Number Pipe Size A B CSBSTUO100EI3 1" 67/8" 1" CSBSTUO125EG 1 1/4' 73/8" 1" CSBSTUO150EG 1 1/2" 73/4' 1' CSBSTU0200EG 2" 8 1/8" 13/16" CSBSTU0250EG 2 1/2" 8 7/8' 1 3/16" CSBSTU0300EG 3" 93/8" 13/16" CSBSTU0400EG 4" 10 5/8" 1 1/2" CSBSTU0500EG 5' 12 1/8" 1 1/2" CSBSTU0600EG 6" 135/8" 2" CSBSTUO800EG 8" 15 3/4" 2' CSBSTU1000EG 10" 18" 2" CSBSTUO100ND 67/8" 1" CSBSTUO125HD I 1/4 73/8" 1'• CSBSTUO15OHD 11/2" 73/4" 1" CSBSTU0200HD 8 1/8" 13/16" CSBSTU025OHD 21/2" 87/8" 1 3/16" CSBSTU0300HO 93/8" 13/16" CSBSTU0400HD 10 5/8" 1 1/2" CSBSTU0500HD 5' 121/8" 1 1/2' PENTAIR Part Number Pipe Size A B CSBSTU0600HD 6" 13 5/8 2" CSBSTU0800HD 8' 153/4" 2' CSBSTU1000HD 10 18' 2' UL Loads (Listed for Restraints) - Part Number Dyna-Flow® Service Pipe Sch 10 Service Pipe Sch 40 Service Pipe CSBSTUO100xx N/A 655 lb 655 lb CSBSTU0125xx 655 lb 655 lb 655 lb CSBSTU0150xx 655 lb 655 lb 655 lb UL Loads Listed for Sway Braces) Lateral Longitudinal Part Number Dyna-Flow® Service Pipe EZ FLOWTM Service Pipe Sch 10 Service Pipe Sch 40 Service Pipe Dyne-Flow® Service Pipe EZ FLDWTM Service Pipe Sch 10 Service Pipe Sch 40 Service Pipe CSBSTU0200xx 3,000 lb N/A 3,000 lb 3,000 lb N/A N/A N/A N/A CSBSTU0250xx 3,000 lb N/A 3,000 lb 3,000 lb 2.015 lb N/A 2,015 lb 2.015 lb CSBSTU0300xx 3.000 lb N/A 3,000 Lb 3,000 lb 2.015 lb N/A 2,015 lb 2,015 lb CSBSTU0400xx 3,000 lb 3.000 lb 3.000 Lb 3.000 lb 2.015 lb N/A 2.015 lb 2,015 lb CSBSTU0500xx N/A 3,000 lb 3,000 lb 3,000 lb N/A N/A 2,015 lb 2.015 lb CSBSTU0600xx N/A 3.000 lb 3,000 lb 3.000 lb N/A 2,015 lb 2,015 lb 2.015 lb CSBSTU0800xx N/A N/A 3.000 lb 3,000 lb N/A N/A 2.015 lb 2.015 lb CSBSTU1000xx N/A N/A 3.000 lb 3.000 lb N/A N/A 3,000 lb 3,000 lb FM Loads (Lighlwalt, Sch 10 and Sch 40 Service Pipes) Horizontal Capacity per Installation Angle from Vertical Pert Number Lateral Longitudinal 30o -44o 450 - 59° 60° - 74° 75° - 90° 30° - 44° 45 -590 60o - 74° 75° - 90° CSBSTUO100xx 860 lb 1,220 lb 1.500 lb 1,670 lb 970 lb 720 lb 860 lb 960 lb CSBSTU0125xx 860 lb 1,220 lb 1,500 lb 1,670 lb 970 lb 720 lb 860 lb 960 lb CSBSTU0150xx 860 lb 1.220 lb 1,500 lb 1.670 lb 970 lb 720 lb 860 lb 960 lb CSBSTU0200xx 1.530 lb 2.160 lb 2.650 lb 2,960 lb 870 lb 690 lb 830 lb 930 lb CSBSTU0250xx 1,530 lb 2,160 lb 2,650 lb 2.960 lb 870 lb 690 lb 830 lb 930 lb CSBSTU0300xx 1.530 lb 2.160 lb 2.650 lb 2.960 lb 870 lb 690 lb 830 lb 930 lb CSBSTU0400xx 1,570 lb 2,220 lb 2,720 lb 3,030 lb 1,550 lb 1.390 lb 1,680 lb 1.870 lb CSBSTUOSOOxn 1,570 lb 2,220 lb 2.720 lb 3,030 lb 1,550 lb 1.390 lb 1,680 lb 1.870 Lb CSBSTU0600xx 1.980 lb 2,810 lb 3,440 lb 3.840 lb 1.470 lb 1,170 lb 1,410 lb 1.570 lb FM Loads (0.188" wall and Sch 40 Service Pipes) Horizontal Capacity per Installation Angle from Vertical Part Number Lateral Longitudinal 30° - 440 45 - 59° 60o -740 75° - 90° 30° - 44° 45° - 59° 60° - 74° 75° - 90° CSBSTU0800nx 2,040 lb 2,890 lb 3,540 lb 3,950 lb 1,200 lb 1,700 lb 2.090 lb 2,330 lb CSBSTU1000xx 2,040 lb 2.890 lb 3,540 lb 3.950 lb 1,200 lb 1,700 lb 2,090 lb 2.330 lb II PENTAIR Dyna-Flow is a registered trademark of Allied Tube & Conduit Corporation. FM is a registered certification mark of FM Approvals LLC. LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL. UR, cUL. cUR, cULus and cURuu are registered certification marks of UL LLC. WARNING Pentair products shall be installed and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.penlair.com and from your Pentair customer service representative. Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product matfunction, property damage, serious bodily injury and death and/or void your warranty. © 2016 Pentair All rights reserved Pentair, CADDY. CADWELD, CRITEC. ERICO. ERIFLEX. ERITECH and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. MC14DDY PENTAIR Universal design allows one product to attach directly to concrete, wood, bar joist or I-beam adapters Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Use for both lateral and longitudinal sway brace applications Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Center bolt does not require tightening Meets NFPA®-13 requirements for seismic sway bracing A Material: Steel C(&US <~~> OSHPD APPROVED Part Number Finish Hole Size HS A B C CSBUNIV050EG Etectrogatvanized 9/16" 5 1/4' 4" 1 5/8" CSBUNIV075EG Eleclrogalvanized 13/16" 5 1/4" 4" 15/8" CSBUNIV05OHD Hot-Dip Galvanized 9/16" 5 1/4" 4" 1 5/8" UL Loads Brace Type Service Pipe Size Rating Pipe 1"- 10" 3,000 lb 1/4" Thick Angle 1" -8" 2,015 lb FM Loads Brace Type Service Pipe Size Horizontal Capacity per Installation Angle from Vertical 300 - 44 450 - 590 60o - 74o 75 - 900 Pipe N/A 1,620 lb 2,300 tb 2,820 lb 3,140 lb al +PENTAIR FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association. Inc. UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC. WARNING Pentair products shall be instaLled and used only as indicated in Pentair's product instruction sheets and training materials. Instruction sheets are available at erico.pentair.com and from your Pentair Customer service representative. Improper instattation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. © 2016 Pentair Alt rights reserved Pentair. CADDY. CADWELD, CRITEC. ERICO. ERIFLEX. ERITECH and LENTON are owned by Pentair or its global affiliates. Alt other trademarks are the property of their respective owners. Pentair reserves the right to Change specifications without prior notice. PENTAIR ES-757DCDA/757NDCDA Job Name _______________________________________ Contractor Job Location Approval Engineer Contractors P.O. No. Approval Series 757DCDA, 757NDCDA Double Check Detector Assemblies Sizes: 21/2 ' —loll 65 - 250mm) Series 757DCDA, 757NDCDA Double Check Detector Assemblies are used to prevent backflow of non-health hazard pollutants that are objectionable but not toxic, from entering the potable water supply system. The 757DCDA, 757NDCDA may be installed under continuous pressure service and may be subjected to backpressure and backsiphonage. Series 757DCDA, 757NDCDA is used primarily on fire line sprinkler systems when it is necessary to monitor unauthorized use of water. Features Extremely compact design 70% Lighter than traditional designs 304 (Schedule 40) stainless steel housing & sleeve Groove fittings allow integral pipeline adjustment Patented tn-link spring check provides lowest pressure loss Unmatched ease of serviceability Available with grooved butterfly valve shutoffs May be used for horizontal, vertical or N pattern installations Replaceable check disc rubber Specifications The Double Check Detector Assembly shall consist of two independent tn-link check modules within a single housing, sleeve access port, four test cocks and two drip tight shutoff valves. Tr-link checks shall be removable and serviceable, with- out the use of special tools. The housing shall be constructed of 304 Schedule 40 stainless steel pipe with groove end con- nections. Tr-link checks shall have reversible elastomer discs and in operation shall produce drip tight closure against reverse flow caused by backpressure or backsiphonage. The bypass assembly shall consist of a meter, which registers in either gal- lon or cubic measurement, a double check backflow assem- bly and required test cocks. Assembly shall be a Watts Series 757DCDA, 757NDCDA. Representative 757000ABFG 757NDCDAOSY NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with with-INWAM out prior notice and out incurring any obligation to make such changes and modifications on Watts products previously or subsequeney sold. S Available Models Suffix: OSY - UL/FM outside stem and yoke resilient seated gate valves BFG - UL/FM grooved gear operated butterfly valves with tamper switch 5y FxG - Flanged inlet gate connection and grooved outlet gate connection 5y GxF - Grooved inlet gate connection and flanged outlet gate connection 5y GxG - Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory* *Consult factory for dimensions Dimensions - Weight Materials Housing & Sleeve: 304 (Schedule 40) Stainless Steel Elastomers: EPDM, Silicone and Buna-N Tr-link Checks: Noryl®, Stainless Steel Check Discs: Reversible Silicone or EPDM Test Cocks: Bronze Body Nickel Plated Pins & Fasteners: 300 Series Stainless Steel Springs: Stainless Steel Pressure - Temperature Temperature Range: 33°F - 140°F (0.5°C - 60°C) Maximum Working Pressure: 175psi (12.1 bar) Approvals Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The Unversity of Southern California (FCCCHR-USC) AWWA C551-92 **).SSIF/40 4e OPUS C®US&d 1048 B64.5 (**BFG & OSY Only) 757DC13A, 757NDCIJA SIZE (ON) DIMENSIONS WEIGHT in. mm A in. mm ClOS in. mm D in. mm 6 in. mm H in. mm I in. mm J in. mm P in. mm 7570CDA lbs. kgs. 757NDCDA lbs. kgs. 2½ 65 30/4 781 16/8 416 3½ 89 291/16 738 211/2 546 15½ 393 813A6 223 133A6 335 139 63 147 67 3 80 3134 806 18/8 479 3W16 94 30¼ 768 221/4 565 171/8 435 9346 233 14½ 368 159 72 172 78 4 100 333/4 857 22/4 578 4 102 33 838 231/2 597 18½ 470 915,46 252 15346 386 175 79 198 90 6 150 1 431/2 1105 1 301/8 765 1 51/2. 140 443/4 1137 33¼ 845 233A6 589 13'A& 332 19 483 309 140 350 159 8 200 1 493/4 1264 1 373/4 959 1 6W16 170 54½ 1375 401/8 1019 27/16 697 1511A6 399 213/1 538 494 224 569 258 10 250 1 571/4 1467 1 453/4 1162 1 8346 208 1 66 1676 1 491/2 1257 321/2 826 175A& 440 24 610 795 361 965 438 757DCDABFG, 757NDCDABFG 11(LJI DIMENSIONS WEIG in. mm A in. mm C in. mm 0 in. mm 6 in. mm H in. mm I in. mm J in. mm P in. mm 757DCDABFG lbs kgs. 757NDCDABFG lbs. kgs. 2½ 65 273/4 705 8 203 31/2 89 29/ 759 211/2 546 1415A6 379 813A 223 13 330 70 32 78 35 3 80 281/4 718 8346 211 311A6 94 30A6 779 22Y4 565 15V16 392 9346 233 13½ 343 68 31 81 37 4 100 29 737 815A6 227 3A6 94 311346 811 231/2 597 16Y4 412 915,46 252 14 356 75 34 98 44 6 150 361/2 927 10 254 5 127 43346 1097 33Y4 845 19W16 500 131,46 332 1 14½ 368 131 59 171 78 8 200 423/, 1086 12/4 311 61/2 1 65 51V16 1297 40Y8 1019 235A6 592 1 l5hh/16 399 1 183A 462 1 275 125 1 351 159 Noryl® is a registered trademark of General Electric Company. 4" (100mm) Service flow Rated Flow *UL Rated Flow N V H 100 200 300 400 500 600 700 800 gpm 380 760 1140 1520 1900 2280 2660 3040 1pm 7.5 13 fps Psi 24 20 16 0. 12 E 8 4 0 0 0 psi 12 10 6 4 0 Capacity Series 757DCDA, 757NDCDA flow curves as tested by Underwriters Laboratory. Flow characteristics collected using butterfly shutoff valves Horizontal ______ Vertical ------N - Pattern 21A" (65mm) PSI Service Flow Rated Flow *UL Rated Flow 14 d q EE rrn o 50 100 150 200 250 300 350 gpm 0 190 380 570 760 950 1140 1330 1pm 7.5 15 fps Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. Rated Flow identifies maximum continuous duty performance determined by AWWA. UL Flow Rate is 150% of Rated Flow and is not recommended for continuous duty. AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than lofps. 6" (150mm) SI Service Flow Rated Flow *UL Rated Flow 12 N ______ ______ ____ -. 10 H 0 6 00 4 0 0 300 600 900 1200 1500 gpm 0 1140 2280 3420 4560 5700 1pm 7.5 12 fps 3" (80mm) psi Service flow Rated flow *UL Rated Flow 12 10 — z 6-~' 4 0 0 100 200 300 400 500 gpm 0 380 760 1140 1520 1900 1pm 7.5 15 fps psi 8" (200mm) Service Flow Rated flow 111 Rated Flow 12 4J N 10 00 H 8 Cd, 6 4 EE 2 0 500 1000 1500 2000 2500 gpm 0 1900 3800 5700 7600 9500 1pm 7.5 10 fps 10" (250mm) Service flow Rated flew UL Rated Flow I I LIi 0 500 1000 1500 2000 2500 3000 3500 gpm 0 1900 3800 5700 7600 9500 11400 13300 1pm 7.5 10 fps AtIlitDi Inquire with governing authorities for local installation requirements It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes. S %WArrS® USA: Tel: (978) 689-6066 • Fax: (978) 975-8350 • Wattscom Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • Watts.ca Latin America: Tel: (52) 81-1001-8600 ES-757DCDA_757NDCDA 1730 © 2017 Watts