HomeMy WebLinkAbout6133 INNOVATION WAY; ; FPC2017-0123; Permit (2)(10 k70tyof PERMIT REPORT Carlsbad Print Date: 10/21/2021 S Permit No: FPC2017-0123 Job Address: 6133 INNOVATION WAY, CARLSBAD, CA 92009-1728 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132612400 Track #: Applied: 05/11/2017 Valuation: $218,969.08 Lot #: Issued: 06/12/2017 Occupancy Group: Project #: Finaled Close Out: 08/12/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: HOUSE OF AIR -SPRINKLER TI 7-100 HEADS (76) FPContractor: SYMONS FIRE PROTECTION INC 12155 PAINE PL POWAY, CA 92064-7154 (619) 588-6364 FEE S AMOUNT FIRE Expedited Plan Review Per Hour - Office Hours S $132.00 FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $668.00 Total Payments To Date: $668.00 • Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 011 Hydraulic Overview , . . . D Job Number: 17-0085 Renort flesrxintjnn- I inht k7t1rrt Rpctiirpr1 Aran ('stir- (It Job - Job Ne,*,e, Dmçn EngN000 17-0085 Francisco Ibarra Jab Name: House of Air TI Phone (619)588-6364 FAX (619)588-6805 Addysse I 6133 Innovation Way State CodJfioatjantUoemse beebe, C16 682025 Addme. 2 Carlsbad, CA AJIJ Carlsbad Fire Department MAce,, 3 Jab siteiSttliding 6133 Innovation Way System Dentay P000 eltWpbootiafl 0.loogpmlft2 900.0oft2 (Actual 916.85ft2) Meat Denstndtn Sp,i-ddec teSt Hose 500am, 5.6 K-Factor 14.82 at 7.000 100.00 Cooe,ege Pet Spebtte, Nombo, olspebkle,, Cabotated 130.0oft2 10 System P,euae Canard syltetfl Floe, co- 56.864 160.65 Total Domand 260.65 @56.864 Ploesen Rost.N +17.044(23.1%) Supplies Check Point Gauges Node Name Flow(pm) Hose Flowlgpm) Static(psil Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(ppm) 1 Water Supply 2000.00 100.00 74.000 70.000 BOR 40.142 25.36 160.65 FPC20I7-0123 6133 INNOVATION WAY House of Air Tl.cad Water Supply at Node 1 (2000.00, 100.00, 74.000, 70.000) 100- 111 1 tatic Pressure 74.000 70- 00070.00 60 - 60.65 @ 56.864— CL 60.65 with hose streams 50- FILM 40- System demand curve 30- 10- 0- - UJIIII UJJUJJ LLWIJ. .LLLLLLL' U.IJJ.LLL° 111111111 11111111 4000 W920016002000 2400 3200 2800 3600 Water flow, gpm ,®M.E.P.CAD, Inc. M AutoSPRlNK®12v12.0.57.0 5/4/2017 2:09:22PM Page 1 01 lmyqtakqao-~wn Job Number: 17-0085 Reoort Descriotion: Liaht Hazard- Reduced Area Calc (1 Job '-.• I - -. - . .:. Job Otoobot 17-0085 00ign Cflgbo.r Francisco Ibarra Job Name: House of Air TI Stat. Cortaoatlorsluoenoo Nunnbor C16 682025 Add, 010 1 6133 Innovation Way MIJ Carlsbad Fire Department Mdtm.o 2 Carlsbad, CA Job SlloiBtJtdsig 6133 Innovation Way AdJt0103 Motot,çsomo House of Air Tl.cad System Remote Area(s) Most Domottottg Spthtldor Data 5.6 K-Factor 14.82 at 7.000 000opgfloy Light Hazard- Reduced Area Caic Job 50110 Ha.. AOoxxaroo Al Soato. 100.00 DenSIty 0.l00gpmlft2 Pt.. o1Ap0000tlon 900.00ft2 (Actual 916.85ft2) Adda(onot Moo. Sp0pte. Node Flow(ppm) 010ttbet OfSpPttdoxcol0100tltd 10 Cavotogo Pet Sptbntdot 130.00ft° AunoPe.k Moult,: Pt...,.. Fat Rotnoto Moo(s) bojaoatl To Most Rortoto Area Left: 56.687 2088.69ga1 Total Hoax So- 100.00 Systonn Flow Donnond 160.65 Total OWlet RoqMod (InoN01ttg Hose Alonooro.) 260.65 M.xin,an Pn055j.o Unbotattoo ta Loops 0.000 Moalnnotn VoMolty Above Gtoond 14.82 between nodes 7 and 39 Mao)tt,onVolodty Undo, Gtootoo 1.62 between nodes 4 and 6 Vabotro "POCKY otOWt Pipos Vobono oattaotly at Day Plyos Supplies Node Name Hose Flow (gpm) Static (psi) Residual (psi) Flow (gpm) Available Total Demand (psi) (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 100.00 74.000 70.000 I 2000.00 73.908 I 260.65 56.864 17.044 Contractor Cattttao101 flwnbor 55 Cartoon Name Gustavo Ortega Cottony TOtS PM Name at CoIt.otor Nu Build Petane (619) 995-6882 Extension tlddteto 1 FAX Addt000 2 Evtnoil Mdtosa3 10tSb-SIte , © M.E.P.CAD, Inc. AutoSPRINK® 12 02.0.57.0 5/4/2017 2:09:24PM Page 2 011Hydraulic Graph Job Number: 17-0085 Renôrt flpstrintinn I inht Hi,rd- Rpdtu-p1 Ari (Ir (I' Water Supply at Node I 100— 90T 80— tatic Pressure 74.000 70— 2000.00 @ 70.000 60— 160.65 t 56.864 260.65 with hose streams 0 50— 40— S istern demand 30— curve 20— 10— 0_111L1l1.1.I.l.1.l.1.1hhhhhhhhhhhhhhhhh1111111111 111111111 IllIllIll 111111111 III 111111 0400 800 1200 1600 2000 2400 2800 3200 3600 4000 Water flow, gpm Hydm,k G,Ph Water Supply at Node 1 Sk Pore 74.000 RldI. Pm,o Tog Cotd By Tom BytnBd By 70.000 @ 2000.00 Carlsbad Fire Department Jenifer Mael Aflibb Pmsswo at Itmo 01 ToOl 0010 OOTOZI limo of Tent 73.908@260.65 4.202017 Peak System BenW,d Hydrant NumberS L000l1on 56.864 @ 160.65 H20918 6133 Inovation way Sy,10nr00rw411rd01ng Hum Atbumos atHobto) Hydrant Elovotlon 56.864 @ 260.65 379 , © M.E.P.CAD, Inc. 51 AutoSPRINK® 12 02.0.57.0 5/4/2017 2:09:25PM Page 3 Job Number: 17-0085 Pnnrt fl,'nniinn- I i,.ht Dua,I,.wl A, ii BOR 100-: go- 80— -Static Pressure 74.000 70— 000.00 t 70.000 in - 0. - I °1 40—--- 160.65 40.142 260.65 with hose streams 30- 20- S stem demand curve 10--- 0 I.I.I.I.I..L.i 111111111 111111111 II 111111 liii II II I I I I I I I I I I I I I I I I I I I I I I I I 0100 800 1200 1600 2000 2400 2800 3200 3600 4000 Water flow, gpm Kyd,auav Graph 8CR Guile; blue N/A ResIdual; P- N/A Available Pvenu,e RI Thee Of Teal N/A 000e,nOenraua 40.142 © 160.65 Sterno eualbnuv,eeeaealuveuvee elSosee) 40.142 © N/A , © M.E.P.CAD, Inc. AutoSPRINK® 12 v12.0.57.0 5/4/2017 2:09:25PM Page 4 Job Number: 17-0085 Reoort Descriotion: Lioht Hazard- Reduced Area Calc 11' Node Elevation(Foot) Fttings Pressure(psi) Discharge(gpm) 41 35-0 P0(16-5%) 25.310 42 2-9 T(3-7%) 7.694 43 2-9 C(6-7%) 7.896 44 2-9 T(10-11) 9.013 45 2-9 T(3'-71/.) 8.852 46 34-0 P0(16-51/.) 25.738 47 35-0 P0(16-51/2) 25.310 48 34-0 P0(16-51/2) 25.738 49 35-0 P0(16-51/2) 25.310 50 34-0 P0(16-51/2) 25.738 51 35-0 P0(16-51/2) 25.310 52 34-0 P0(16-5%) 25.738 53 35-0 P0(16-5%) 25.310 54 34-0 P0(16-5%) 25.738 55 35-0 P0(16-51/2) 25.310 56 34-0 P0(16-51/2) 25.738 57 35-0 P0(16-51/2) 25.310 58 34-0 P0(16-51/2) 25.747 59 35-0 P0(16-51/2) 25.320 60 35-0 P0(16-51/2) 25.324 61 34-0 P0(16-51/2) 25.750 62 34-0 P0(16-51/2) 25.745 63 35-0 P0(16-5%) 25.317 64 35-0 P0(16-5%) 25.325 65 34-0 P0(16'-51/2) 25.751 66 34-0 P0(16-5%) 25.741 67 35-0 P0(16-51/2) 25.314 68 35-0 P0(16-5%) 25.326 69 34-0 P0(16-5%) 25.752 70 34-0 P0(16-51/2) 25.738 71 35-0 P0(16-51/2) 25.248 72 35-0 P0(16-51/2) 25.327 73 34-0 P0(16-51/,) 25.753 74 34-0 P0(16-51/2) 25.738 75 35-0 P0(16-51/2) 25.310 76 35-0 P0(16-51/2) 25.327 1 -5-0 ST(44-8) 56.864 160.65 101 2-9 SFr(-7.360) 7.360 15.19 102 2-9 Srr(-11.875) 11.875 19.30 103 2-9 Sr(-7.554) 7.554 15.39 104 2-9 Sr(-11.591) 11.591 19.07 105 2-9 Spr(-7.214) 7.214 15.04 106 2-9 Spr(-7.404) 7.404 15.24 107 2-9 Sr(-7.000) 7.000 14.82 108 2-9 Sr(-7.185) 7:85 15.01 109 2-9 Spr(-8.060) 8.060 15.90 110 2-9 Spr(-7.861) 7.861 15.70 2 -5-0 LtE(16-7) 42.828 3 -5-0 LtE(22-01/2) 56.844 4 -5-0 42.770 5 34-0 LtE(11'-4) 25.804 6 1-0 BOR 40:42 7 2-9 T(16'-51/2), LtE(5'-6) 33.668 8 34-0 P0(16-51/2) 25.757 9 34-0 T(37'-81/2) 25.783 10 35-0 P0(16-51/2) 25.328 11 35-0 P0(16-51/2) 25.351 12 34-0 P0(16-5%) 25.782 - 13 34-0 P0(16-51/.) 25.750 14 35-0 P0(16-51/2) 25.322 15 35-0 P0(16-51/2) 25.351 16 34-0 P0(16-51/2) 25.781 , © M.E.P.CAD, Inc. L11 AutoSPRINK® 12. v12.0.57.0 5/4/2017 2:09:27PM Page 5 ON INode Analysis I Job Number: 17-0085 Report Description: Liqht Hazard- Reduced Area Caic (1' Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 17 34-0 PO(16'-5Y2) 25.744 18 35-0 P0(16-51/2) 25.316 19 35-0 P0(16-5%) 25.351 20 34-0 P0(16-51/2) 25.781 21 34-0 P0(16-51/2) 25.738 22 35-0 P0(16-5%) 24.512 23 35-0 P0(16-5%) 25.351 24 34-0 P0(16-51/2) 25.781 25 34-0 P0(16-51/2) 25.738 26 35-0 P0(16-5%) 25.310 27 35-0 P0(16-51/2) 25.351 28 34-0 P0(16-51/.) 25.781 29 34-0 P0(16-5%) 25.738 30 35-0 P0(16-51/2) 25.310 31 34-0 P0(16-51/2) 25.738 32 35-0 P0(16-51/2) 25.310 33 34-0 P0(16-51/2) 25.738 34 35-0 P0(16-51/.) 25.310 35 34-0 P0(16-51/2) 25.738 36 35-0 P0(16-51/2) 25.310 37 34-0 P0(16-51/2) 25.738 38 35-0 P0(16-51/2) 25.310 39 2-9 T(S'-71/2) 12.940 40 34-0 P0(16-51/2) 25.738 ,©M.E.P.CAD, Inc. 1]AutoSPRINK®12v12.0.57.0 5/4/2017 2:09:27PM Page 0 IHYdraulic Analysis Job Number: 17-0085 Report Description: Light Hazard- Reduced Area Calc_(1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary Route ..... BL 1.4080 14.82 3.05 120 0.017816 12-0 Pt 0.214 107 105 2-9 2-9 14.82 5.6 7.000 7.214 Sprinkler 12-0 Pe Pv BL 1.4080 29.86 6.15 120 0.065132 0-9 Pt 0.480 105 42 2'-9 2-9 15.04 5.6 7.214 7.694 Sprinkler, 1(6-71/.) 6-71/2 7-41/2 Pe Pv BL 2.1040 45.05 4.16 120 0.019713 10-3 Pt 0.202 42 43 2-9 2-9 15.19 7.694 7.896 Flow (q) from Route 3 10-3 Pe Pv BL 2.1040 90.69 8.37 120 0.071929 4-71/2 Pt 1.118 43 44 2-9 2-9 30.25 + 15.39 7.896 9.013 Flow (q) from Route 2 and 4 T(10'-11) 10-11 15-6% Pe Pv BL 2.1040 122.29 11.28 120 0.125051 15-0% Pt 3.926 44 39 2-9 2-9 31.60 9.013 12.940 Flow (q) from Route 5 E(5-51/2), T(10'-11) 16-4 31-5 Pe Pv BL 2.1040 160.65 14.82 120 0.207162 69-61/2 Pf 20.729 39 7 2-9 2'-9 38.36 12.940 33.668 Flow (q) from Route 6 3E(5-51/2), 1(10-11), LtE(5'-6) 30-61/2 100-0% Pe Pv BL 2.6350 160.65 9.45 120 0.069237 44-10% Pt 4.819 7 22 2-9 35-0 33.668 24.512 E(8-3), Z, P0(16-51/.) 24-81/2 69-71/2 Pe Pv -13.976 RN 2.6350 128.33 7.55 120 0.045695 1-0 P1 0.798 22 21 35-0 34-0 24.512 25.738 P0(16-5%) 16-5% 17-51/2 Pe Pv 0.428 FM 6.3570 127.99 1.29 120 0.000624 10-0 Pf 0.006 21 17 34-0 34-0 25.738 25.744 10-0 Pe Pv FM 6.3570 129.43 1.31 120 0.000637 10-0 Pf 0.006 17 13 34-0 34-0 1.44 25.744 25.750 Flow (q) from Route 14 10-0 Pe Pv FM 6.3570 131.61 1.33 120 0.000657 10,-0 Pt 0.007 13 8 34-0 34-0 2.18 25.750 25.757 Flow (q) from Route 13 10-0 Pe Pv FM 6.3570 134.46 1.36 120 0.000683 0-7 Pt 0.026 8 9 34-0 34-0 2.85 25.757 25.783 Flow (q) from Route 12 1(37-81/2) 37-8% 38-31/2 Pe Pv FM 6.3570 160.65 1.62 120 0.000950 11,-a Pt 0.021 9 5 34-0 34-0 26.19 25.783 25.804 Flow (q)from Route 7 LtE(11'-4) 11-4 22-4 Pe Pv FR 6.3570 160.65 1.62 120 0.000950 33-0 Pt 0.031 5 6 34-0 1-0 25.804 40.142 f(-0.000), BOR 33-0 Pe Pv 14.306 UG 6.3570 160.65 1.62 150 0.000629 26-0 Pt 0.027 6 4 1,-0 -5-0 40.142 42.770 LtE(17'-l) 17-1 43-1 Pe Pv 2.601 UG 7.7100 160.65 1.10 150 0.000246 150-0 Pf 0.058 4 2 -5-0 -5-0 42.770 42.828 3E(22'-11½), LtE(16'-7) 85'-6 235-6 Pe Pv UG 8.3900 160.65 0.93 140 0.000185 20-51/2 Pt 14.016 2 3 -5-0 -5-0 42.828 56.844 3LtE(22'-01/2), f(-14.000) 66'-2 86'-71/2 Pe Pv UG 7.7100 160.65 1.10 150 0.000246 30-0 Pt 0.020 3 1 -5,-0 -5-0 56.844 56.864 GV(5'-l%), S, T(44'-8) 49-9% 79-9% Pe Pv 100.00 Hose Allowance At Source 1 260.65 Gib ..... Route 2 ..... BL 1.4080 15.01 3.09 120 0.018252 12-0 P1 0.219 108 106 2'-9 2'-9 15.01 5.6 7.185 7.404 Sprinkler 12-0 Pe Pv BL 1.4080 30.25 6.23 120 0.066722 0-9 Pt 0.492 106 43 2'-9 2-9 15.24 5.6 7.404 7.896 Sprinkler, C(6'-71/2) 6-71/2 7-4% Pe Pv =. ..... Route 3 ..... BL 1.4080 15.19 3.13 120 0.018663 11-3 Pt 0.333 101 42 2'-9 2'-9 15.19 5.6 7.360 7.694 Sprinkler, T(6'-71/2) 6-7% 17-10% Pe Pv Route ..... BL 1.4080 15.39 3.17 120 0.019117 11-3 Pt 0.342 103 43 2'-9 2-9 15.39 5.6 7.554 7.896 Sprinkler, C(6'-71/2) 6'-7% 17-101/2 Pe Pv , © M.E.P.CAD, Inc. fflAutoSPRINKO 12 02.0.57.0 5/4/2017 2:09:28PM Page 7 -M Job Number: 17-0085 Report Description: Light Hazard- Reduced Area Calc_(1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary =. ..... Route S ..... BL 1.4080 15.70 3.24 120 0.019835 10-0 Pf 0.198 110 109 2-9 2'-9 15.70 5.6 7.861 8.060 Sprinkler 10-0 Pe Pv BL 1.4080 31.60 6.51 120 0.072338 4-4 Pt 0.792 109 45 2-9 2-9 15.90 5.6 8.060 8.852 Sprinkler, 1(6-71/2) 6-71/2 10-111/2 Pe Pv BL 2.1040 31.60 2.92 120 0.010229 15-9% Pt 0.162 45 44 2-9 2-9 8.852 9.013 15'91/2 Pe Pv =. ..... Route 6 ..... BL 1.4080 19.07 3.93 120 0.028406 10-0 Pt 0.284 104 102 2-9 2-9 19.07 5.6 11.591 11.875 Sprinkler 10-0 Pe Pv BL 1.4080 38.36 7.90 120 0.103560 3-8 Pt 1.065 102 39 2-9 2-9 19.30 5.6 11.875 12.940 Sprinkler, 1(6-71/2) 6-71/2 10-31/2 Pe Pv - Route 7 ..... FM 4.2600 5.13 0.12 120 0.000011 10-0 Pt 0.000 73 77 34-0 34-0 25.753 25.753 10-0 Pe Pv RN 2.6350 5.13 0.30 120 0.000118 1-0 Pt 0.002 77 76 34-0 35-0 25.753 25.327 P0(16-51/2) 16-51/2 17-51/2 Pe Pv -0.428 BL 2.6350 5.13 0.30 120 0.000118 173-51/2 Pt 0.024 76 27 35-0 35-0 25.327 25.351 P0(16-51/2) P0(16-5%) 32-111/2 206-5 Pe Pv RN 2.6350 5.13 0.30 120 0.000118 1-0 Pt 0.002 27 28 35-0 34-0 25.351 25.781 P0(16-51/2) 16-5% 17-51/2 Pe Pv 0.428 FM 6.3570 5.13 0.05 120 0.000002 10-0 Pt 0.000 28 24 34-0 34-0 25.781 25.781 10-0 Pe Pv FM 6.3570 10.27 0.10 120 0.000006 10-0 Pt 0.000 24 20 34-0 34-0 5.14 25.781 25.781 Flow (q) from Route 8 10-0 Pe Pv FM 6.3570 15.46 0.16 120 0.000013 10-0 Pt 0.000 20 16 34-0 34-0 5.19 25.781 25.781 Flow (q) from Route 9 10-0 Pe Pv FM 6.3570 20.75 0.21 120 0.000022 10-0 Pt 0.000 16 12 34-0 34-0 5.28 25.781 25.782 Flow (q) from Route 10 10-0 Pe Pv FM 6.3570 26.19 0.26 120 0.000033 9,-5 Pt 0.002 12 9 34-0 34-0 5.45 25.782 25.783 Flow (q) from Route 11 1(37-81/2) 37'-81/2 47-2 Pe Pv Route ..... RN 2.6350 32.32 1.90 120 0.003564 1-0 Pt 0.062 71 70 35-0 34-0 32.32 25.248 25.738 Flow (q) from Route 20 P0(16-51/2) 16-51/2 17-5% Pe Pv 0.428 FM 4.2600 32.66 0.74 120 0.000350 10-0 Pt 0.004 70 66 34-0 34-0 0.34 25.738 25.741 Flow (q) from Route 15 lU-U Pe Pv FM 4.2600 31.22 0.70 120 0.000322 10-0 Pt 0.003 66 62 34-0 34-0 25.741 25.745 10-0 Pe Pv FM 4.2600 29.04 0.65 120 0.000282 10-0 Pt 0.003 62 58 34-0 34-0 25.745 25.747 10-0 Pe Pv FM 4.2600 26.19 0.59 120 0.000233 10-0 Pt 0.002 58 61 34-0 34-0 25.747 25.750 10-0 Pe Pv FM 4.2600 20.75 0.47 120 0.000151 10,-0 Pt 0.002 61 65 34-0 34-0 25.750 25.751 10,-0 Pe Pv FM 4.2600 15.46 0.35 120 0.000088 10.-0 Pt 0.001 65 69 34-0 34-0 25.751 25.752 10,-0 Pe Pv FM 4.2600 10.27 0.23 120 0.000041 10,-0 Pt 0.000 69 73 34-0 34-0 25.752 25.753 10,-U Pe Pv RN 2.6350 5.14 0.30 120 0.000119 1,-0 Pt 0.002 73 72 34-0 35-0 25.753 25.327 P0(16-5%) 16-51/2 17-5% Pe Pv -0.428 (,®M.E.P.CAD, Inc. MjAutoSPRINKO12v12.U.57.0 5/4/2017 2:09:28PM Page 8 0 N IHYdraulic Analysis D Job Number: 17-0085 Report Description: Light Hazard- Reduced Area Calc_(1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary BL 2.6350 5.14 0.30 120 0.000119 173-51/2 Pt 0.025 72 23 35-0 35-0 25.327 25.351 P0(16-51/2) P0(16-51/2) 32-111/2 206-5 Pe Pv RN 2.6350 5.14 0.30 120 0.000119 1-0 Pt 0.002 23 24 35-0 34-0 25.351 25.781 P0(16-51/2) 16-51/2 17-51/2 Pe 0.428 jPv =. ..... Route 9 ..... RN 2.6350 5.19 0.31 120 0.000121 1-0 Pt 0.002 69 68 34-0 35-0 25.752 25.326 P0(16-51/2) 16-51/2 17-5% Pe -0.428 Pv BL 2.6350 5.19 0.31 120 0.000121 173-51/2 Pt 0.025 68 19 35-0 35-0 25.326 25.351 P0(16-51/2) P0(16-51/2) 32-111/2 206-5 Pe Pv RN 2.6350 5.19 0.31 120 0.000121 1-0 Pt 0.002 19 20 35-0 34-0 25.351 25.781 P0(16-51/2) 16-51/2 17-5% Pe 0.428 Pv Route 10 ..... RN 2.6350 5.28 0.31 120 0.000125 1-0 Pt 0.002 65 64 34-0 35-0 25.751 25.325 P0(16-51/2) 16-5% 17-5% Pe -0.428 Pv BL 2.6350 5.28 0.31 120 0.000125 173-51/2 Pf 0.026 64 15 35-0 35-0 25.325 25.351 P0(16-5%) P0(16-51/2) 32-111/2 206-5 Pe Pv RN 2.6350 5.28 0.31 120 0.000125 1-0 Pt 0.002 15 16 35-0 34-0 25.351 25.781 PO(16'-5'/.) 16-5% 17-5% Pe 0.428 Pv Route 11 ..... RN 2.6350 5.45 0.32 120 0.000132 1-0 Pt 0.002 61 60 34-0 35-0 25.750 25.324 PO(16'-51/2) 16-5% 17-5% Pe -0.428 Pv BL 2.6350 5.45 0.32 120 0.000132 173-51/2 Pt 0.027 60 11 35-0 35-0 25.324 25.351 P0(16-51/2) P0(16-5%) 32-11% 206-5 Pe Pv RN 2.6350 5.45 0.32 120 0.000132 1-0 Pt 0.002 11 12 35-0 34-0 25.351 25.782 P0(16-5%) 16-5% 17-5% Pe 0.428 Pv Route 12 ..... RN 2.6350 2.85 0.17 120 0.000040 1-0 Pt 0.001 58 59 34-0 35-0 25.747 25.320 P0(16-51/2) 16-51/2 17-5% Pe -0.428 Pv BL 2.6350 2.85 0.17 120 0.000040 173-51/2 Pt 0.008 59 10 350 35-0 25.320 25.328 P0(16-51/2) P0(16-51/2) 32-11% 206-5 Pe Pv RN 2.6350 2.85 0.17 120 0.000040 1-0 Pt 0.001 10 8 35-0 34-0 25.328 25.757 P0(16-51/2) 16-5% 17-5% Pe 0.428 Pv =. ..... Route 13 ..... RN 2.6350 2.18 0.13 120 0.000024 1-0 Pt 0.000 62 63 34-0 35-0 25.745 25.317 P0(16-51/2) 16-51/2 17-5% Pe -0.428 Pv BL 2.6350 2.18 0.13 120 0.000024 173-5% Pt 0.005 63 14 35-0 35-0 25.317 25.322 P0(16-5%) P0(16-5%) 32-11% 206-5 Pe Pv RN 2.6350 2.18 0.13 120 0.000024 1-0 Pt 0.000 14 13 35-0 34-0 25.322 25.750 P0(16-51/2) 16-51/2 17-51/2 Pe 0.428 Pv Route 14 ..... RN 2.6350 1.44 0.08 120 0.000011 1-0 Pt 0.000 66 67 34-0 35-0 25.741 25.314 P0(16-51/2) 16-51/2 17-5% Pe -0.428 Pv BL 2.6350 1.44 0.08 120 0.000011 173-51/2 Pt 0.002 67 18 35-0 35-0 25.314 25.316 P0(16-51/2) P0(16-51/2) 32-11% 206-5 Pe Pv RN 2.6350 1.44 0.08 120 0.000011 1-0 Pt 0.000 18 17 35-0 34-0 25.316 25.744 P0(16-51/2) 16-5% 17-5% Pe 0.428 Pv Route 15 ..... RN 2.6350 0.05 0.00 120 0.000000 1-0 Pt 0.000 57 56 35-0 34-0 0.05 25.310 25.738 Flow (q) from Route 16 P0(16-51/2) 16-51/2 17-5% Pe 0.428 Pv FM 4.2600 0.05 0.00 120 0.000000 10-0 Pt 0.000 56 54 34-0 34-0 25.738 25.738 10-0 Pe Pv 71 . ©M.E.P.CAD, Inc. MAutoSPRINKO12v12.0.57.0 5/4/2017 2:09:28PM Page 9 s . - Hydra-uIu7An -aIysus I Job Number: 17-0085 Report Description: Light Hazard- Reduced Area Calc (1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary FM 4.2600 0.09 0.00 120 0.000000 10-0 Pt 0.000 54 52 34-0 34-0 0.05 25.738 25.738 Flow (q) from Route 25 10-0 Pe Pv FM 4.2600 0.14 0.00 120 0.000000 10-0 Pt 0.000 52 50 34-0 34-0 0.05 25.738 25.738 Flow (q) from Route 17 10-0 Pe Pv FM 4.2600 0.18 0.00 120 0.000000 10-0 Pt 0.000 50 48 34-0 34-0 0.05 25.738 25.738 Flow (q) from Route 23 10-0 Pe Pv FM 4.2600 0.23 0.01 120 0.000000 10-0 Pt 0.000 48 46 34-0 34-0 0.05 25.738 25.738 Flow (q) from Route 18 10-0 Pe Pv FM 4.2600 0.28 0.01 120 0.000000 40-3 Pt 0.000 46 74 34-0 34-0 0.05 25.738 25.738 Flow (q) from Route 21 2E(13-2) 26-4 66-7 Pe Pv FM 4.2600 0.34 0.01 120 0.000000 10-0 Pt 0.000 74 70 34-0 34-0 0.06 25.738 25.738 Flow (q) from Route 19 10-0 Pe Pv Route 16 ..... FM 6.3570 0.09 0.00 120 0.000000 10-0 Pf 0.000 35 37 34-0 34-0 25.738 25.738 10-0 Pe Pv FM 6.3570 0.05 0.00 120 0.000000 10,-0 Pt 0.000 37 40 34-0 34-0 25.738 25.738 10,-0 Pe Pv RN 2.6350 0.05 0.00 120 0.000000 1-0 Pt 0.000 40 41 34-0 35-0 25.738 25.310 P0(16-51/2) 16-51/2 17-5% Pe Pv -0.428 BL 2.6350 0.05 0.00 120 0.000000 14321,4 Pt 0.000 41 57 35-0 35-0 25.310 25.310 P0(16-51/2) P0(16-5%) 32-111/2 176-2 Pe Pv =...... Route 17 ..... FM 6.3570 0.18 0.00 120 0.000000 10,-0 Pt 0.000 31 33 34-0 34-0 25.738 25.738 10,-0 Pe Pv FM 6.3570 0.14 0.00 120 0.000000 10,-0 Pt 0.000 33 35 34-0 34-0 25.738 25.738 10,-0 Pe Pv RN 2.6350 0.05 0.00 120 0.000000 1,-0 Pt 0.000 35 36 34-0 35-0 25.738 25.310 P0(16-5%) 16-51/2 17-5% Pe Pv -0.428 BL 2.6350 0.05 0.00 120 0.000000 143-2'/z Pt 0.000 36 53 350 35'-0 25.310 25.310 PO(16'-51/2) PO(16'51/2) 32111/2 176-2 Pe Pv RN 2.6350 0.05 0.00 120 0.000000 i-a Pt 0.000 53 52 35-0 34-0 25.310 25.738 P0(16-51/2) 16-51/2 17-5% Pe Pv 0.428 =. ..... Route 18 ..... FM 6.3570 0.28 0.00 120 0.000000 10-0 Pt 0.000 25 29 34-0 34'-0 25.738 25.738 , 10,-0 Pe Pv FM 6.3570 0.23 0.00 120 0.000000 10,-0 Pt 0.000 29 31 34-0 34-0 25.738 25.738 ia-a Pe Pv RN 2.6350 0.05 0.00 120 0.000000 1-0 Pt 0.000 31 32 34-0 35-0 25.738 25.310 P0(16-51/2) 16-51/2 17-51/2 Pe Pv, -0.428 BL 2.6350 0.05 0.00 120 0.000000 143-21/2 Pt 0.000 32 49 35-0 35-0 25.310 25.310 P0(16-51/2) P0(16-51/2) 32-111/2 176-2 Pe Pv RN 2.6350 0.05 0.00 120 0.000000 1-0 Pt 0.000 49 48 35-0 34-0 25.310 25.738 P0(16-51/2) 16-5% 17-5% Pe Pv 0.428 =. ..... Route 19 ..... FM 6.3570 0.34 0.00 120 0.000000 10-0 Pt 0.000 21 25 34-0 34-0 25.738 25.738 10-0 Pe Pv RN 2.6350 0.06 0.00 120 0.000000 1-0 Pt 0.000 25 26 34-0 35-0 25.738 25.310 P0(16-51/2) 16-51/2 17-5% Pe Pv -0.428 BL 2.6350 0.06 0.00 120 0.000000 173-51/2 Pt 0.000 26 75 35-0 35-0 25.310 25.310 P0(16-51/2) 2P0(16-51/,) 49-5 222-101/2 Pe Pv , © M.E.P.CAD, Inc. MAutoSPRINKO 12 02.0.57.0 5/4/2017 2:09:28PM Page 10 Hydraulic Analysis Job Number: 17-0085 Report Description: Light Hazard- Reduced Area Calc_(1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Upstream Discharge K-Factor Pt Pn Fittings Eq. Length - Total Length Summary RN 2.6350 0.06 0.00 120 0.000000 1-0 Pt 0.000 75 74 35-0 34-0 25.310 25.738 P0(16-5%) 16-51/2 17-5% Pe 0.428 lPv Route 20 ..... BL 2.6350 32.32 1.90 120 0.003564 173-5% Pt 0.736 22 71 35-0 35-0 24.512 25.248 P0(16-51/2) P0(16-51/.) 32-111/2 206-5 Pe Pv Route 21 ..... RN 2.6350 0.05 0.00 120 0.000000 1-0 Pf 0.000 47 46 35-0 34-0 0.05 25.310 25.738 Flow (q) from Route 22 P0(16-51/2) 16-5% 17-5% Pe 0.428 Pv =. ..... Route 22 ..... RN 2.6350 0.05 0.00 120 0.000000 1,-0 Pf 0.000 29 30 34-0 35-0 25.738 25.310 P0(16-51/2) 16-51/2 17-5% Pe -0.428 Pv BL 2.6350 0.05 0.00 120 0.000000 143-21/2 Pf 0.000 30 47 35-0 35-0 25.310 25.310 P0(16-51/.) P0(16-51/2) 32-111/2 176-2 Pe Pv =. ..... Route 23 ..... RN 2.6350 0.05 0.00 120 0.000000 1-0 P1 0.000 51 50 35-0 34-0 0.05 25.310 25.738 Flow (q) from Route 24 P0(16-51/2) 16-51/. 17-5% Pe 0.428 Pv Route 24 ..... RN 2.6350 0.05 0.00 120 0.000000 1-0 P1 0.000 33 34 34-0 35-0 25.738 25.310 P0(16-5%) 16-51/2 17-51/2 Pe -0.428 Pv BL 2.6350 0.05 0.00 120 0.000000 143-2% Pt 0.000 34 51 35-0 35-0 25.310 25.310 P0(16-51/2) P0(16-5%) 32-11% 176-2 Pe Pv =. ..... Route 25 ..... RN 2.6350 0.05 0.00 120 0.000000 1-0 Pt 0.000 55 54 35-0 34-0 0.05 25.310 25.738 Flow (q) from Route 26 P0(16-51/2) 16-51/2 17-5% Pe 0.428 Pv Route 26 ..... RN 2.6350 0.05 0.00 120 0.000000 1,-0 Pt 0.000 37 38 34-0 35-0 25.738 25.310 P0(16-51/2) 16-51/. 17-51/2 Pe -0.428 Pv BL 2.6350 0.05 0.00 120 0.000000 143-21/2 P1 0.000 38 55 35-0 35-0 25.310 25.310 P0(16-51/2) P0(16-5%) 32-111/2 176-2 Pe Pv lEquivalent Pipe Lengths of Valves and Fittings (C=120 Only) I Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter k 4.87 ) = Factor IC Value Multiplier Value Of C 100 Multiplying Factor 0.713 130 140 150 1.16 1.33 1.51 (. © M.E.P.CAD, Inc. MAutoSPRINK@ 12 02.0.57.0 5/4/2017 2:09:28PM Page 11 Hydraulic Analysis I Job Number: 17-0085 neporr uescripuon: LIgm -iazara- reauceatrea Laic (1) Flow Velocity HWC Friction Loss Length IPressure P=am Diameter Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream I Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BalV Ball Valve DR Drop Velocity fps BFP Backflow, Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DelV Deluge Valve SP Sprig Pt Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe Pe Pressure due to elevation difference between indicated points E 90° Elbow UG Underground Pv Velocity pressure at a point in a pipe EE 45° Elbow Eel 11W Elbow Ee2 221W Elbow Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node IT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PlV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap . © M.E.P.CAD, Inc. NJ AutoSPRINK® 12 v12.0.57.0 5/4/2017 2:09:28PM Page 12 f CC 2,0 J `+ - Di 13 tqca Worldwide Contacts www.tyco-fire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM and VdS Approved CE Certified Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/bar112) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) JANUARY 2013 Finishes Sprinkler: Natural Brass, Chrome Plated, Pure White (RAL 9010) and Signal White (RAL 9003). Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFP172 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector, can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON * 6 7/16" _______ I NOMINAL : I (11,1 mm) (50,8 mm) MAKE-IN I 1-3/8" 2" (50,8 mm) _______ WF _______ (34,9 mm) 14 Fl 1/2" NPT** DEFLECTOR * 2-7/8' (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS /(USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin' ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) - 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) MOUNTING \ 1/8 J \ - ___ __ _______ FLUSH 3/8±5/16 (9,5±7,9 mm) , T_ (3,2 mm) SURFACE _____ CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. FITTING - (57,2 mm) 5/16±1/4" / (7,9±6,4 mm) \ 1/2" (12,7 mm) I—. FLUSH ZIn MOUNTING / \ . J I SURFACE/// ,j \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8(34,9mm) TY-FRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON rp TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX I I SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 370 5.6K UPRIGHT (1/2 NPT) TY313 4 SIGNAL WHITE (RAL 9003) 371 5.6K PENDENT (1/2 NPT) TY323 3 PURE WHITE (RAL 9010)°° Use suffix "I' for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS - PART NUMBER SELECTION - Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (SIN), K=5.6, (Upright or Pendent) Sprinkler Quick Response, (specify) temperature rat- ing, (specify) finish, P/N (Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 135 135°F(57°C) 155 155°F(68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286°F (141°C) GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. t TEFLON is trademark of The DuPont Corporation. tqCo Fire Suppression & Building Products Technical Services 800-381-9312 I +1-401-781-8220 www.tyco.fire.com Series DS-1 Dry-Type Sprinklers 5,6K Pendent. UDriqht, and Horizontal Sidewall Standard Response, Standard Coverage General Description TYCO Series DS-1 Dry-Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Standard Response (5 mm Bulb) and Standard Coverage, are decorative glass bulb automatic sprin- klers typically used where: pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures; for example, sprinkler drops from unheated portions of buildings sprinklers and/or a portion of the connecting piping may be exposed to freezing temperatures; for example, sprinkler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through a wall to protect unheated areas of a building such as loading docks, over- hangs, and building exteriors sprinklers are used on systems that are seasonably drained to avoid freezing; for example, vacation resort areas NOTICE Series DS-1 Dry-Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association, in addition to IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 the standards of any other Authorities Having Jurisdiction. Failure to do so may impair the performance of these devices. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manu- facturer should be contacted with any questions. Series DS-1 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Model/Sprinkler Identification Numbers (SINs) TY3255 - Pendent TY3155 - Upright TY3355 - Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved LPCB Approved: Ref No. 094a/11 CE Certified: EN 122.59-1 NYC Approved under MEA 352-01-E Refer to Table A. Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1-inch NPT (Standard Order) ISO 7-Ri Discharge Coefficient K = 5.6 GPM/psi112 (80,6 LPM/barll2) Temperature Ratings Refer to Table A. MAY 2011 Finishes Sprinkler: Natural Brass, Chrome Plated, White Polyester Escutcheon: White Coated, Chrome Plated, Brass Plated Physical Characteristics Inlet.....................Copper Plug ....................Copper Yoke ..............Stainless Steel Casing ...............Galvanized Carbon Steel Insert ...................Bronze Bulb Seat ..........Stainless Steel Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze Frame ...................Bronze Guide Tube.........Stainless Steel Water Tube.........Stainless Steel Spring.............Stainless Steel Sealing Assembly. . . Beryllium Nickel w/Teflon' Escutcheon ..........Carbon Steel 'DuPont Registered Trademark ii jTFP500 Page 2 of 10 TY3255 Pendent TY3255 Pendent TY3355 Horizontal Sidewall with top of Deflector-to-Ceiling with Standard with Standard Escutcheon distance of 4 to 12 inches Recessed Escutcheon (Figure 5) (100 to 300 mm) (Figure 3) with Wide Flange with Deep Escutcheon with Standard Escutcheon Recessed Escutcheon (Figure 6) (Figure 9) (Figure 4) without Escutcheon with Deep Escutcheon Temperature Bulb Color (Figure 7) (Figure 10) Rating Code TY3155 Upright without Escutcheon (Figure 13) Escutcheon without (Figure 8) SPRINKLER FINISH Natural Chrome White Natural Chrome White Natural Chrome White Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F (57°C) Orange 1,23,5 1,2,5 1,2,3,4,5 1,2,4,5 1*,2*,3**,4,5 1*2*4,5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue N/A 4, 5 360°F (182°C) Mauve N/A 1°, 2*, 5 N/A Notes Listed by Underwriters Laboratories, Inc. (maximum order 4. Loss Prevention Certification Board and CE conformity length of 48 inches) apply to these temperature ratings only Listed by Underwriters Laboratories for use in Canada 5. Approved by the City of New York under MEA 352-01-E (maximum order length of 48 inches) * Light and Ordinary Hazard Occupancies Only Approved by Factory Mutual Research Corporation ** Light Hazard Occupancies Only (maximum order length of 48 inches) N/A - Not Available TABLE A SERIES DS-1 STANDARD RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS - LABORATORY LISTINGS AND APPROVALS - PLUG WITH INLET SEALING ASSEMBLY YOKE SPRING INLET BAND WATER II II TUBE CASING GUIDE - INSERT - TUBE BULB 71. FRAME SEAT 5mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 1 SERIES DS-1 STANDARD RESPONSE DRY-TYPE SPRINKLERS - ASSEMBLY - - WRENCH RECESS WRENCH 02 (_ FLAT , PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 7 SPRINKLER WRENCH I TFP500 Page 3 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 2-3/4to48 1-3/4" DIA. (69,9 to 1219,2 mm) (44,5 mm) IN 1/4' (6,4 mm) INCREMENTS FACE OF CEILING 2-3/16±1/8" 3" DIA. (55,6 ± 3,2 mm) (76,2 mm) FIGURE 3 PENDENT TY3255 WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-3/4' to 48" (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) 2-1/4' DIA. INCREMENTS (57,2 mm) FACE OF CEILING FIGURE 4 PENDENT TY3255 WITH STANDARD RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: —3 1/2" DIA. 1/2' to 46' (88,9 mm) (12,7 to 1168,4 mm) I I IN 1/4' (6,4 mm) 2-1/2" DIA INCREMENTS _ FACOF _ (63,5 5 mm CEILING 4-1/4" ± 1/8" (108,0 ± 3,2 mm) FIGURE 5 PENDENT TY3255 WITH DEEP ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 5 to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING FIGURE 6 PENDENT TY3255 WITHOUT ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48' (127,0 to 1219,2 mm) IN 1/4' (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING - SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 7 UPRIGHT TY3 155 WITHOUT ESCUTCHEON TFP500 Page 4 of 10 ORDER LENGTHS: 2-3/4 to 48" (69,9 to 1219,2 mm) IN 1/4' (6,4 mm I ) INCREMENTS 4' ± 1/8' (101,6 3,2 mm) ± FACE OF FACE OF 1 DIA. - SPRINKLER MOUNTING (44,5 mm) FITTING SURFACE 3" DIA. (76,2 mm) SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16' CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 8 TY3355 HORIZONTAL SIDEWALL WITH STANDARD ESCUTCHEON Operation When TYCO Series DS-1 Dry-Type Sprinklers are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly (Figure 1) in the Inlet of the Sprinkler. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet, allowing the sprinkler to activate and flow water. Design Criteria ORDER LENGTHS: FACE OF 1/2' to 45-3/4" (12,7 toll 62,1 mm) MOUNTING IN 1/4" (6,4 mm) INCREMENTS SURFACE - FACE OF 2-1/2' DIA. (63,5 mm) SPRINKLER FITTING 4-13/16±1/8" (122,2 ± 3,2 mm) TYCO Series DS-1 Dry-Type Sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 require- ments. For more information on LPCB Approval, contact TYCO Fire Suppression & Building Products at the following office: SPRINKLER FITTING (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 9 TY3355 HORIZONTAL SIDEWALL WITH DEEP ESCUTCHEON ORDER LENGTHS: 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 2-1/4" (57,2 mm) FACE OF 1 DEFLECTOR TO - SPRINKLER I MOUNTING SURFACE II 3.5* 5/16" SPRINKLER FITTING (7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 10 TY3355 HORIZONTTAL SIDEWALL WITHOUT ESCUTCHEON Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 Sprinkler Fittings Install 1-inch NPT Series DS-1 Dry-Type Sprinklers are to be installed in the 1-inch NPT outlet or run of the following fittings: malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125). Do not install Series DS-1 Dry-Type Sprinklers into elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow. The unused outlet of the threaded tee is plugged as shown in Figure 12. You can also install Series DS-1 Dry-Type Sprinklers in the 1-inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. TFP500 Page 5 of 10 Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area' 40°F (4°C) 50°F (10°C) 60°F (16°C) Minimum Exposed Barrel Length, Inches (mm)2 40°F (4°C) 0 0 0 30-F (-1-C) 0 0 0 20°F (-7°C) 4 (100) 0 0 10°F (-12°C) 8 (200) 1 (25) 0 0-F (-18-C) 12 (305) 3(75) 0 -10°F (-23°C) 14 (355) 4 (100) 1 (25) -20°F (-29°C) 14 (355) 6 (150) 3 (75) -30°F (-34°C) 16 (405) 8 (200) 4 (100) -40°F (-40°C) 18 (455) 8 (200) 4 (100) -50°F (-46°C) 20 (510) 10 (255) 6 (150) -60°F (-51°C) 20 (510) 10 (255) 6 (150) Notes For protected area temperatures that occur between values listed above, use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE B EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS - MINIMUM RECOMMENDED LENGTHS - The configuration shown in Figure 13 is only applicable for wet pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry-Type Sprinkler has the minimum exposure length depicted in Figure 11. Refer to the Exposure Length section. For wet pipe system installations of 1-inch NPT Series DS-1 Dry-Type Sprinklers connected to CPVC piping, use only the following TYCO CPVC fittings: 1" x 1" NPT Female Adapter (P/N 80145) 1" x 1" x 1" NPT Sprinkler Head Adapter Tee (P/N 80249). For dry pipe system installations, use only the side outlet of maximum 2-1/2- inch reducing tee when locating Series DS-1 Dry-Type Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 12 to assure complete water drainage from above Series DS-1 Dry-Type Sprinklers and the branch line. Failure to do so may result in pipe freezing and water damage. LL.1tLg Do not install Series DS-1 Dry-Type Sprinklers into any other type fitting without first consulting the Technical Services Department. Failure to use the appropriate fitting may result in one of the following: Failure of the sprinkler to operate prop- erly due to formation of ice over the Inlet Plug or binding of the Inlet Plug. Insufficient engagement of the Inlet pipe-threads with consequent leakage. Drainage In accordance with the minimum requirements of the National Fire Protection Association for dry pipe sprinkler systems, branch, cross, and feed-main piping connected to Dry Sprinklers and subject to freezing temperatures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use Table B to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the connecting pipes due to conduction. The exposed barrel length measure- ment must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. Refer to Figure 11 for an example. For protected area temperatures between those given above, the minimum recommended length from the face of the fitting to the outside of the protected area may be determined by interpolating between the indicated values. Clearance Space In accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13, when connecting an area subject to freezing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry-Type Sprinklers must be sealed. Due to temperature differences between two areas, the potential for the formation of condensation in the sprinkler and subsequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry-type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. RUN OUTLET PLUGGED PRINKLER FITTING TO DRY (SEE DESIGN SYSTEM CRITERIA SECTION) DSB-2 INTENDED FOR FREEZER STRUCTURES FIGURE 12 SPRINKLER FITTING - UNHEATED AREA - TO WET SIDE SYSTEM OUTLET IiJ7J PLUGGED DSB-2 SPRINKLER INTENDED Ti FITTING FOR FREEZER I I (SEE DESIGN i-L CRITERIA STRUCTURES SECTION) FIGURE 13 SPRINKLER FITTING - HEATED AREA - ,TFP500 Page 6of 10 FACE OF SPRINKLER - - FITTING EXPOSURE ________ LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES FIGURE 11 - EXPOSURE LENGTH - STRAP TIES 111I (ENDS ON OPPOSING SIDES OF BOOT) DSB-2 BOOT J ADHESIVE 1-3/4 DIA. - (44,5 mm) CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 DRY SPRINKLER BOOT WITH PENDENT SERIES DS- I DRY-TYPE SPRINKLER 1-3/4 DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE I STRUCTURE DSB-2 BOOT STRAP TIES (ENDS ON DS-1 OPPOSING SHOWN WITH SIDES OF STANDARD BOOT) ESCUTCHEON FIGURE 15 MODEL DSB-2 DRY SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY-TYPE SPRINKLER I ,TFP5OO Page 7 of 10 Installation TYCO Series DS-1 Dry-Type Sprinklers must be installed in accordance with the following instructions. NOTICE Series DS-1 Dry-Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Refer to the Design Criteria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 360°F (182°C) rating. Obtain a leak-tight 1-inch NPT sprinkler joint by applying a minimum-to- maximum torque of 20 to 30 ft. lbs. (26,8 to 40,2 Nm). Higher levels of torque may distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under or over- tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Install pendent sprinklers only in the pendent position; install upright sprinklers only in the upright posi- tion. The deflector of a pendent or upright sprinkler is to be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their centerline of waterway perpendic- ular to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. With a non-hardening pipe-thread sealant such as Teflon applied to the Inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Wrench-tighten the sprinkler using either: a pipe wrench on the Inlet Band or the Casing (Figure 1). the W-Type 7 Sprinkler Wrench on the Wrench Flat (Figure 2). Apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat. Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guide- lines were followed. After removal, inspect the sprinkler for damage. 4. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling! wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance TYCO Series DS-1 Dry-Type Sprinklers must be maintained and serviced in accordance with the following instructions. NOTICE - Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (Figure 1) to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protection system control valve and drain the system before removing the sprinkler. Exercise care to avoid damage before, during, and after installation. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never repaint factory-painted Cover Plates. When necessary, replace cover plates with factory-painted units. Non-factory applied paint can adversely delay or prevent sprinkler operation in the event of a fire. Replace sprinklers that: were damaged by dropping, striking, wrench twisting, wrench slippage, or the like. were modified or over-heated. have cracked bulbs or have lost liquid from the bulbs. Refer to the Installation Section in this data sheet. are leaking or exhibiting visible signs of corrosion. Responsibility lies with owners for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other Authorities Having Jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Automatic sprinkler systems are recom- mended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. *DuPont Registered Trademark ,JTFP5OO Page 8 of 10 Limited Warranty Products manufactured by Tyco Fire Suppression and Building Products (TFSBP) are warranted solely to the original Buyer against defects in material and workmanship when paid for and properly installed and main- tained under normal use and service. This warranty will expire twelve (12) months from installation or eighteen (18) months from delivery, whichever occurs first. No warranty is given for products or components manufac- tured by companies not affiliated by ownership with TFSBP or for products and components which have been subject to misuse, improper instal- lation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with appli- cable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFSBP shall not be respon- sible for sprinkler system design errors or inaccurate or incomplete infor- mation supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possi- bility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a partic- ular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name, including description and Part Number (P/N). Dry Sprinklers When ordering 5.6 K-Factor Series DS-1, Standard Response , Standard Coverage (5 mm Bulb), Dry-Type Automatic Sprinklers, specify the following information: Model/SIN Pendent TY3255, Upright TY3155, or Horizontall Sidewall TY3355 Deflector Style Order Length Dry-Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 10, as applicable. After the measurement is taken, round it to the nearest 1/4 inch increment. Inlet Connections 1-inch NPT or ISO 7-R1 Temperature Rating Sprinkler Finish Escutcheon Style and Finish, as applicable Part Number from Table B. Part numbers are for 1-inch NPT standard order sprinklers. Orders for all other sprinkler assemblies must be accom- panied by a complete description. Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002. This Part Number includes one Boot, two Strap Ties, and 1/3 oz. of Adhesive (a suffi- cient quantity for installing one boot). SPRINKLER FINISH NATURAL BRASS WHITE POLYESTER CHROME PLATED CHROME PLATED ESCUTCHEON FINISH (1) WHITE WHITE CHROME WHITE I TEMPERATURE RATING (2) 0 135°F (57°C) 1 155°F (68°C) 2 175°F (79°C) 3 200°F (93°C) 4 286°F (141°C) 5 360°F (182°C) ORDER LENGTH (3) 055 5.50" 082 8.25" 180 18.00" 187 18.75" 372 37.25" 480 48.00" I Ii TFP500 Page 9 of 10 P/N* 60 - XXX - X - XXX MODEL/SIN 96 Pendent with Standard TY3255 1 Escutcheon (1" NPT) (Figure 3) 93 Pendent with Deep 1Y3255 4 Escutcheon (1" NPT) (Figure 5) 97 Pendent with Standard TY3255 Recessed Escutcheon (1° NPT) (Figure 4) 92 Pendent without TY3255 ro Escutcheon (1° NPT) (Figure 6) NATURAL BRASS BRASS PLATED Sidewall with Standard TY3355 94 Escutcheon (1° NPT) (Figure 8) 53 Sidewall with Deep TY3355 Escutcheon (1° NPT) (Figure 9) 54 Sidewall without TY3355 Escutcheon (1° NPT) (Figure 10) 98 Upright without TY3155 Escutcheon (1' NPT) (Figure 7) Notes * Use Prefix "I" for ISO 7-R1 Connection; for example, 1-60-961-1-180). Escutcheon Finish applies to sprinklers provided with escutcheons. 286°F (141°C) and 360°F (182°C) temperature ratings apply to non-recessed sprinkler assemblies. Dry-Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 10, as appli- cable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 inch increment. TABLE C SERIES DS-1 STANDARD RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS - PART NUMBER SELECTION - ,TFP5OO Page 10 of 10 Copyright © 2007, 2011 Tyco Fire Suppression & Building Products. All rights reserved.