HomeMy WebLinkAbout6133 INNOVATION WAY; ; FPC2018-0176; Permit4City of PERMIT REPORT Carlsbad CARLSBAD, CA 92009-1772 Work Class: Fire Sprinklers Track #: Lot #: Project #: DEV2017-0113 Plan #: Construction Type: Orig. Plan Check #: Plan Check U: Permit No: FPC2018-0176 Status: Closed - Finaled Applied: 06/11/2018 Issued: 06/25/2018 Finaled Close Out: 02/12/2020 Inspector: Final Inspection: Print Date: 10/21/2021 Job Address: 6133 INNOVATION WAY, # 101, Permit Type: FIRE-Construction Commercial Parcel #: 2132612400 Valuation: $621,658.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: ACOUSTIC ALES BREWING COMPANY Description: HYDRO ACOUSTIC ALES BREWERY -SPRINKLER TI (41 HEADS) FPContractor: BRIAN SULLIVAN 1975 SPANISH OAK WAY VISTA, CA 92081-7383 (760) 716-9226 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Permit No: FPC2018-0176 Fire Sprinklers Status: Approved - Ready to Issue Applied: 06/11/2018 DEV2017-0113 Issued: Permit Finaled: Inspector: Final Inspection: (?ity of C arlsbad Print Date: 06/18/2018 Job Address: 6133 Innovation Way, 101 Permit Type: FIRE-Construction Commercial Work Class: Parcel No: 2132612400 Lot #: Valuation: $621,658.00 Reference #: Occupancy Group: Construction Type: # Dwelling Units: Bathrooms: Bedrooms: Orig. Plan Check #: Plan Check #: Project Title: ACOUSTIC ALES BREWING COMPANY Description: ACOUSTIC ALES BREWERY - SPRINKLER TI (41 HEADS) Applicant: SULLY FIRE PROTECTION BRIAN SULLIVAN 760-727-3444 Fire Prevention Contractor: SULLY FIRE PROTECTION 1975 Spanish Oak Way VISTA, CA 92081-7383 760-716-9226 FEE AMOUNT FIRE NFPA 13 or 13R System 7- 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $0.00 Balance Due: $536.00 Fire Department 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ' 6133 INNOVATION WAY # 101 ACOUSTICALES BREWERY-SPRINKLER TI (41 HEADS) FiRE PER 1635Faraday1 DEV20170h13 2132612400 iE Phone: 760-6d 6/11/2018 FPC20I 8-0176 Project Information Project Name AC0t'1,c, At4c tci Project Address 14 'p4i)oVAT,o4 t.ÜAY SiyWe. 9___________ Scope of Work MOW'( ($4 _P144._YsTft'Pap... _14ir .:54PPVCr14f Associated Building Permit #(if applicable) I9 _2at7 ke Spider System: 'Ni1ber dfthsers 4. 'Nber oPheads E1'e A'bnn :'E trsnbor of ydrats 0 Sprinkler Monitoring 0 Other 0 New system. Tenant Improvement Contractor Fnformation Company Name cI41' ftPE P&T04 tcr7ccei OAX WAY sta4k TM qua pp?cartName ItP ~%iU1iVA4 Phone 760_71t - ____Email 50 LF 9@ Aol.. CoWl -Contractor License Number and rypeO. tI 70iO Exp ate - - City Business Lic r 405 Signature Date Dennis Grubb and Associates, LLC Assisting Cities Build Safe communities To: City of Carlsbad 1635 Faraday Ave Carlsbad, CA 92008 Date: 6/14/18 DGA #: C8288 Carlsbad Permit #: FPC20I8-0176 Attention: Fire Prevention Department Project Address: 6133 Innovation Way PLAN TYPE O Alarm Sys (new) U Architectural New- 0 Sprinkler TI 7-100 Heads U Underground 0 Lg 0 Sm U Special Extinguish Sys U Spray Booth: # U Hazardous Material (Non H) U Special Hazard: U Other: U Alarm Sys (TI) U AS Monitoring U Architectural: R-1 A-2 U HPS U Sprinkler New U Sprinkler 13D 0 <100 0 > 100 Risers: U Hood Suppression Sys U Fire Pump U Pre-Action System U AST/UST U Compressed/Med Gas U Solar System U Chem Class: 0<10 0 10-25 0 26-100 LI> 100 U Conditional Use Permit U Site PLAN STATUS Z APPROVED: The plans have been reviewed for compliance to applicable agency codes and standards. The plans are approved for issuance for applicable permit(s) pending the approval of any other applicable County/City agencies. U NOT APPROVED: The plans have been reviewed for compliance to applicable agency codes and standards. Corrections are required before the plans can be approved. See the attached correction letter. Comments: Fees: $165 6550 Van Buren Blvd, Ste F, Riverside, CA. 92503 (800) 9757395 * (951)772-0007 t2 Bulletin 909 Rev. B R 11ab,le Model N25 (SIN RA09I 2) K25.2 (360 metric) Early Suppression Fast Response Sprinkler w CD Co 0 Co CD Product Description The Reliable Model N25 Early Suppression Fast Re- sponse Sprinkler (ESFR/Quick Response Storage Sprin- kler) is intended for use against severe fire challenges. This sprinkler is designed to respond quickly to growing fires and deliver a heavy water discharge to "suppress" rather than control." The Model N25 ESFR sprinkler utilizes a levered fus- ible alloy solder link in either a 165°F (74°C) or a 212°F (100°C) rating. FM Global considers this a "Quick Re- sponse" storage sprinkler for use per FM Data Sheet 8-9. The sprinkler has a Nominal K Factor of 25.2 (metric 360). The smaller deflector and frame provide a broad, very symmetrical, hemispherical pattern capable of sup- pressing tires between sprinklers in high storage height areas and at the same time retaining a high momentum central core to penetrate and suppress fires occurring directly beneath the sprinkler in low storage height ar- eas. The N25 ESFR sprinkler is also less susceptible to damage due to smaller deflector and frame design. The lighter N25 ESFR passed rough use and abuse test in the labs without plastic protectors. Application and Installation The Model N25 is an ESFR sprinkler is intended for installation in accordance with NFPA 13 and as a OR Storage Sprinkler for use in all FM Loss Prevention Data Sheets as well as approval of the Authority Having Ju- risdiction. Model N25 ESFR Sprinkler Design Criteria General guidelines: Orientation: Pendent, deflector should be parallel with the ceiling or roof. System Type: Wet Pipe Systems Only Maximum area of coverage: 100 ft2 (9.3m2), greater coverage area are allowable in some cases. Minimum area of coverage: 64 112 (5.8m2) Maximum slope ceiling: 2/12 pitch (9.50) Maximum spacing: 12 ft (3.7m) for building heights up to 30 ft (9.1m) and 10 feet (3.1m) for building heights greater than 30 ft (9.1m) Minimum spacing: 8 feet (2.4m) Deflector distance from walls: At least 4 inches (102mm) from walls, and no more than one-half the allowable distance permitted between sprinklers. Deflector to Top of Storage: at least 36 in (914mm). Deflector to ceiling Distance: 6 - 18 in (152 - 457mm). Center Line of Thermal Sensing Element To Ceiling Distance: 4 - 17 in (101.6 - 425mm). Listings and Approvals FM Approved as a quick response storage sprinkler. CNBOP-PlB Technical Approval. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Technical Data: Sprinkler Maximum Ceiling Sprinkler Identification Classification Temperature Link Frame Temperature Number Color Color (SIN) OF I °c OF I DC Ordinary 165 1 74 Black Uncolored 100 .1 38 RA0912 Intermediate 212 100 White White 150 66 Material Data: Frame Deflector Load Screw Lever Strut Link Assembly Cap Washer Kick Spring Stainless Stainless Stainless Beryllium Nickel i Beryllium Stainless Brass Bronze Steel Steel Steel Soldered Brass Nickel Steel RAME WASHER, KICK SPRING, LINK ASSEMBL CAP LEVER STRUT LOAD SCREW [DEFLECTOR I 909FG02A Fig. 1 Storage Type NFPA FM Open Frame (that is, no solid shelves) Refer to NFPA t3, Single, Double, Multiple-Row, or Portable Rack Storage Chapters 16 and 17. Refer to FM 8-9. of Class l-IV and Group A or B Plastics Solid Pile or Palletized Storage of Class l-IV Refer to NFPA 13, Refer to FM 8-9. and Group A or B Plastics Chapters 14 and 15. Idle Pallet Storage Refer to NFPA 13, Refer to FM 8-24.Chapter 12. Rubber Tire Storage Refer to NFPA 13, Chapter 18. Refer to FM 8-3. Rolled Paper Storage (Refer to the standard) Refer to NFPA 13, Chapter 19. Refer to FM 8-21. Flammable Liquid Storage (Refer to standard) Refer to NFPA 30. Refer to FM 7-29. Aerosol Storage (Refer to the standard) Refer to NFPA 30B. Refer to FM 7-31. Automotive Componejits In Portable Racks Refer to NFPA 13, Refer to FM 8-1 and 8-9. (Control mode only; refer to the standard) Chapter 20. TABLE 1 COMMODITY SELECTION AND DESIGN CRITERIA OVERVIEW FOR MODEL ESFR-25 PENDENT SPRINKLERS 191 Installation Data Sprinkler . Type Thread Size "K" Factor Maximum Working Finish us Met- nc Pressure Pendent 1' NPT 25.2 360 175 psi (12,1 bar) Bronze Only (Al) Maintenance The Model N25 ESFR Sprinkler should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinkler with soap and water, ammo- nia or any other cleaning fluid. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging until used, to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Once operated, automatic sprinklers cannot be reassem- bled and reused. New sprinklers of the same size, type and temperature rating must be installed. A cabinet of re- placement sprinklers should be provided for this purpose. Model N25 ESFR Sprinkler Specification Sprinklers shall be Early Suppression Fast Response (ESFR) pendent suppression mode sprinklers specifically tested and [FM Approved] for commodity storage applica- tions. Sprinkler frame and deflector to be of bronze con- struction. Fusible link assembly shall utilize the strut and lever principle of operation with approved fast response black-painted or white-painted beryllium-nickel thermal element. Water seal shall consist of a Teflon-coated Bell- yule spring washer and brass cap assembly containing no plastic parts. ESFR sprinklers shall have a nominal K-factor of 25.2 with 1" NPT threaded end connections. Sprinkler temperature rating shall be [Ordinary 165°F (74°C)) [Inter- mediate 212°F (100°C)). j- WRENCH FLAT -------. -- _jj__-- LINK ASSEMBLY 1.85(47MM) 03SJ 3.4(86.4MM) 1.55 FRAME ARMS L_. 1.6 (40.6MM) OIA. ---I OOSFGOIA Fig. 3- Model Ni Wrench Use only the Model Ni sprinkler wrench for removal and installation. Any other type of wrench may damage the sprinkler. Note: When handling sprinklers, hold sprinklers only on frame arms and do not apply any force on the link as- sembly. Sprinklers should be tightened between 22 - 30 ft-lbs (29.8 - 40.7 Nm) torque. Sprinklers not tightened to recommended torque may cause leakage or impairment of the sprinkler. Damage sprinklers must be replaced im- mediately. Ordering Information Specify: Temperature rating Thread type 1" NPT or ISO 7-131 Fig. 2 The equipment presented in this bulletin is lobe installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address 0 Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/17 P/N 9999970454 Installation Data Sprinkler Thread Size "K" Factor Maximum Finish WorkingType us Met- Tric Pressure Pendent 1" NPT 25.2 360 175 psi (12,1 bar) Bronze Only (i1) Maintenance The Model N25 ESFR Sprinkler should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinkler with soap and water, ammo- nia or any other cleaning fluid. Remove any sprinkler that has been painted (other than factory applied) or damaged: in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging until used, to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Once operated, automatic sprinklers cannot be reassem- bled and reused. New sprinklers of the same size, type and temperature rating must be installed. A cabinet of re- placement sprinklers should be provided for this purpose. Model N25 ESFR Sprinkler Specification Sprinklers shall be Eatly Suppression Fast Response (ESFR) pendent suppression mode sprinklers specifically tested and [FM Approved] for commodity storage applica- tions. Sprinkler frame and deflector to be of bronze con- struction. Fusible link assembly shall utilize the strut and lever principle of operation with approved fast response black-painted, or white-painted beryllium-nickel thermal element. Water seal shall consist of a Teflon-coated Bell- vile spring washer and brass cap assembly containing no plastic parts. ESFR sprinklers shall have a nominal K-factor of 25.2 with 1" NPT Threaded end connections. Sprinkler temperature rating shall be [Ordinary 165°F (74°C)) [Inter- mediate 212°F (100°C)]. J .- WRENCH FLAT 2.1(53.3MM) -.---. / )UW(ASLV 1.85(47MM) 03 - -- 0 1.85 G /L D8LECTOR—.1/\' I FRAME ARMS mn 1.6 (40.8MM) 01k J 900FGOIA Fig. 2 Fig. 3- Model Ni Wrench Use only the Model Ni sprinkler wrench for removal and installation. Any other type of wrench may damage the sprinkler. Note: When handling sprinklers, hold sprinklers only on frame arms and do not apply any force on the link as- sembly. Sprinklers should be tightened between 22 - 30 ftlbs (29.8 - 40.7 Nm) torque. Sprinklers not tightened to recommended torque may cause leakage or impairment of the sprinkler. Damage sprinklers must be replaced im- mediately. Ordering Information Specify: Temperature rating Thread type 1" NPT or ISO 7-131 The equipment presented in this bulletin is to be installedin accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled ® (800)4,31-1588 Sales Offices W Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. Reliab'le (914) 829-2042 Corporate Offices www.reliabIesprinlder.com Internet Address EG. Printed in U.S.A. 11/17 P/N 9999970454 FireLockTM V36, K5.6 ModeIsV35T V3606 Ataukc 4O.6O. Dry Type Pendants Technical Specifications: :Standard and Quick Response Models: V3606 and V3605 Style: Rendent, Recessed Pendent or Intermediate Level Pendent FY! 'j - flJ Nominal Orifice Size: ½/13.mm s..4 •:.. fl fl Flush Sleeve and Plain Intermediate Extended Recessed Skirt Barrel Approvals/Listings: LEM See Victaulic Publication 10.01 for-more details. Product Description: The Model V36 Series Dr' Type Pendent and Recessed Pendent Sprinklers have been redesigned utilizing stainless steel internal components. The V36. Dry Sprinkler is used in special applications, such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Model V3606 and V3605 Intermediate Level Pendent sprinklers incorporate a water shield plate to, prevent water from higher level sprinklers from interfering with normal operation. These intermediate level sprinklers are designed for use in intermediate levels of-rack storage or other open grate storage arrangements, where they may be exposed to upper level or-ceiling level sprinklers. Coverage For coverage area and sprinkler placement, refer.to NFPA 13 or applicable standards. Job/Owner System No. Location Contractor Submitted By 'Date Orificeinsert: Stainless steefp.er UNS S30300 K-Factor: 5:6lmp.I8.1 Si.' Nominal Thread Size: 1 NPT/33.7 mm Max. Working Pressure: 175'psi/1200 kPa FaètoryHydrostatic Test: 100%@ 500 psi/3450 kPa Mini Operating Pressure: 7psi/48-kPa Temperature Rating: See chart on page 3. For K-Factor when pressure is measured in Bar, multiply Si. units by 10.0. Exaggerated for clarity Spec Section Paragraph Approved.. Date victaulic.com ISprinklers I FireLock" 'K56,'V36 I Publication 40.60 40.60 3123 Rev I Updated 03/2018 0.2018vic1au1ic Company. All rights reserved. 1 4 tauiiC. victaulic.com I Sprinklers I FireLock I K56,-V36l.PubIication4060 Material Specifications: Accessories Deflector: Brass per UNS .C22000 or Stainless Steel per U.NSS30400 Bulb: Glass with glycerin solution BulbNominal Diameter: U 'Standard: 5:0mm Li Quick Response: 3.0 mm SpliiSpacer:.StainlesssteeI:perUNS'.S3O300 Load Screw:Brass :perUNSC36000 Pip Cap: Stainless steel per UNS S30300 Spring Seal Assembly: Teflon2 coated Beryllium nickel alloy and stainless steel per UNS 530300 :Frame: Die cast .brass Outer Tube: Galvanized steel pipe InnerTiube: Stainless..steel: per .UNS 'S:30400 Escutcheon/Plate: 1010 - 10.18 mild steel and stainless steel Torsion Spring:.SST Wire Installation Wrench: Model V36 Open. End. and Recessed Wrenches fit all V36 Series frames. SpriAlder.Finil:. Plain brass 'Li :Chrorne.läted Li White painted3 4 Li Flat black painted-3 Li .Cutom pairtted3 Li VC-2505 55, 200;'286sR0n1y Li Wax4 For cabinets and. other. accessories referto separate sheet; 2.Teflon is registered trademark of Dupont,co. Not available on the Intermediate Level Style Pendent. 4 U Lisled'for'corrosion resistance. UL Listed and FM'Approved for corrosion reststance NOTE Weather resistant, escutcheon available upon request. 40.60 3123 Rev I Updated 03/2018 © 2018 Viclaulic Company. Alirights reserved. victaulic.com 12' , ICt9UIic victaulic.com I Sprinklers I FieLock® I K5.6,'V36 IPblication.40:60 Approvals/Listings: Model APPROVALS/LISTINGS V3606- V3606 V3605 V3605 'OriflceSlze•(Inches) -½ ½ ½ ½ Orifice Size (mm) 13 13 13 13 Nominal 1< Factor Imperial 5:6- .5.6 5.6 5.6' -NominalK Factor 5.1.6 . 8.1 -8.1 81 8.1 Response Quick. Quick Standard Standard Deflector Type -Pendent Recessed Pendent Pendent .Recessed-Pendent Approved Temperature Ratings 135?F/570C. 135°F/57°C. 135°F1570C. 135F/S7°C. 155°F/68C 155°F/680C 1550F/68°C 155F/68X cULus 200°F/93°C 200°F/93°C 2000F/930C 2000F/93°C 286'F/141°C 286°F/141°C 2860F/141*C 286°F/1410C ..135:F/57:C 1350F/570C . 1350F/5rC 135°F1570C FM 15568 155°F/68°C 1550F/680C 200 F/93 C. 200 F/93 C 2869F/141°C 286'F/141°C ° For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.. Note: 'Listings and approval as of. printingTemperatures.are listed forAll hazards .and,approved .(orV3605.and .V3606 dry sprinklers-up-to 48 length. Dimensions: NOTE The "A ",dimension of a dry sprinkler; which extends into a freezer from a wet piping system, must.take into account the wall or ceiling, thickness of the freezer. See IMPORTANT INSTALLATION INFORMATION later in thisdocument. - - Tee with same outlet size --- ------çj as sprinkler thread size. -Tee with same outlet size Tee will, same outlet see ,, as, size. . as sprinkler thread size. ,/'\,. See'imporlant Installation I /"\,t See "Important Installation -See important Installation Information", toter in this this document 1 Information", later in Information", later. in.this document document,I NPT 1" NPT HPT A iw Mis. Dia. (Min. 1W) jHole in Ceiling - Mi t die 1W) iWMin.Dia. TI, r Hole In Ceiling TwoPiece T__.,J Escur eon 21h* Min' _ -I AL TL35010..J oiij Flush Intermediate Level Pendent Tee with same outlet size Tee with same outlet size as sprinkler thread size. r---n -Tee with same outlet size Fr" 11_. as sprinkler thread size. See tmportoat,lnstallation ... as-size. thread'size. I 4J See'Important Installation Information* later in S - this document ee "Important Installation . Information",later in this INPT Information",later in this --- document iNPT T document lWMin.Dia. (Min .1141 otem Ceiling -(Mm. 1W) ______A '5'5 (tutin J Hot ?'Min 01a ein Ceiling 3W-Mis. - Two Piece I Min. Escutcheon - .. ceihngCup 1-1 Plain Barrel ______________ 2% Do- Extended Recessed 40.60 3123 Rev I Updated 03/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 3 . \tuhc victaulic.com I.SprinkIers ,l',FireLockell .K5:6, V36 I Publication 4060 C°' lmportant.lnstatlation'.Iñformation: FOr; detailed instállation.instructions, see .publication t.40. No. .1 Victaulic Model V36 Series Dry sprinklers should be installe'd'in'accordance with 'NFPA .13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler Wrench- may be used with extreme care for lengths up to approximately Excessive 'force: may .'distort-the frame thus destroying the unit. No. 2 Dry sprinklers MUST be.-installedi.only, into the outlet of a cast or malleable iron tee. No.3'DO NOT install dry sprinkl.ersinto any 'couplirgs or threaded elbows. In addition, DO NOT install dry sprinklers into any fitting that interferes with :thread penetration NOTE :Theendseal of the dry sprinkler MUST NOT bottom out in the fitting. HEATED SPACE Diameter of hole Is dependent uponthe type of escutcheon selected. Space must he sealed to present condanwtion (roass See Note -,--,-'-. '--" - 'Insulation - Vortingofmer NOTE: T'he'A dimension ol,a- dry spririkler,,which extends ,into a- freezer from; a. wet piping system, must lake into account the wall or ceiling thickness of the' Freezer. The minimum length of the dry sprinkler should not be less than the lengths specified. in the following table, plus the 'thickness of-the freezer's wall or ceiling ("A". "C" -s- "0"). Refer to the drawing for a representation of the "A" dimension. DO NOT attempt to.modlfy dry sprinklêrs,.since.lhey,are manufactured to this specific "N' dimension. Thefollowing table is used when [he-ambient temperature is maintained between .40'-F/4* C and60"F/16"C around the wet piping'system. Ambient Temperature Exposed to Discharge End of Sprinkler Etcposed Minimum Barrel Length °F/°C inches/mm -40"F/4C 50°F/,1 09C '60"F/1 6C 40 0 0 0 4 0 0 0 30 0 0. -1 0 0 0 20 4 0 0 1.02 0 0 10 8 1 0 -12 '203 25 0 12 1. 0., -18 305 76 0 -10 14 4 1 -23 356 102 25 ~20 '14 6 -29 356 152 '76 -30' 16' 8' 4 -34 406 203 102' -40 18 8 4 -40 457 203' 102 -50 '20 '10 '6 -46 508 254 152, -60 20 10. 6. -Si 5O8 254: 1S2' Note: Exposed minimum barrel lengths are inclusive up to 30-mph/48-kph wind 'velocities COLD SPACE' -TYPICAL SLEEVE 'ANOSKIRT 'CONFIGURATION FOR UAMPLEONLY 40.60 3123 Rev I Updated 03/2018 0 2018 Viclaulic Company. All rights reserved. victaulic.com "4 s-,/'(ct1aIu1ic victaulic.com ISprinkIers .1 FireLock K56, V36 I Publication 40.60 Distribution Patterns: Models V3605, V3606 Penderd, Recessed Pendent & intermediate Level Pendent Distribution Patterns— Trajectory 7;pst 48 kPa IS psi- 103 kFa 30 psi '207.kPa 4 4 4, 2' 4 6 8. 10' 12' 14' 06m Urn .1.8m 2.4n lOan 37ni 43m 7ps1 —..—.. 15 psi 30p51 48kPa 103 Ida 207kPa NOTES: Data shown isapproxirnate and can vary due to differences in installation These graphs Illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLockTM automatic sprinklers. They. are provided as information for guidance in avoiding obstructions to sprinklers and should not he used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire. Codeorthe authority, having'jurisdiction .for.specific iriformatiowregarding. obstructions, ',spacing limitations:and areaof coverage requirements. Failure Ia follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline otthewaterway. B. 2.4 m :6 1.8 m 4, 1.2 m 2 0.6m 0 40.60 3123 Rev I updated 03/2018 0 2018 Victaulic Company. All rights reserved. victaulic.com 5 \4taUuic victauuic.com lSpnnklersl FireLock® I .K56, V36l Publication 40.60 Ratings: 'AvailableWrenches: All, glass, bulbs, are rated for- tern, peraturesfrom -Mode[V360pen End -arid Recessed Wrenches fit all -67°F/-550C to.those shown in table. below V36. S'eries.frames Sprinkler Temperature Classification -Temperature—FfC Glass Bulb Color Nominal Temperature' Rating Maximum Ambient Temperature Allowed Ordinary 135°1`157°.0 1009F/38°C Orange Ordinary 155°F/68°C 100°F/38°C Red Intermediate 200°F/93°C 150°F/650C Green Intermediate 2869F/141°C 2250FJ107°( 'Blue Extra High 8 360°F/1 82°C 300°F/149°C Purple - Open - No Bulb - - AWARNING - Always read and understand installation, care, and maintenance instructions, supplied witheach box of'sprin-- klers, before proceeding with installation of any sprinklers. , Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstructiOn, must be strictly foIIowed Painting, plating, or any re-coating of sprinklers (otherthan that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. O s The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance, and inspection requirements,. refer-ft the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler, systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. lf you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044.0031 USA, Telephone: O 001.610-559-3300. Installation Note Reference should always be made tothe -100 Victaulic.Fieldlnstallation'Handbook for This product shall be manufactured 'hyVictardieor to Victmjlicspecificalions. All, products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed, in accordance with current Victaulic installation/assembly instructions, products for complete installation and assembly data, and aae,available in POP format Victautic.reserves the rigfit.to change-product specifications and.standard equipment on our website'at-www.viclaUlic.com. without noticeandwithout incurring obligations. Warranty Trademarks Refer to the'Warronty section of the current Price List or contact Victaulic for details. Victaulic and Firetock' are registeredtrademutks of Victaulic Company. 40.60 3123 Rev I Updated 03/2018 © 2018 Victaulic Company. All rights-reserved. ',,tauIc victaulic.com 6: tq a Fire Protection Products Workfwtd Contact : www.tyco-flre.com Series TYFRB, 5.6 Kafactor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General .Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY3I.3) and Pendent TY323 Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light OT ordinary hazard, commercial occupan- cies such as banks, hotels ,and shop- ping malls.. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment. provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling-and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permaneh tly damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation orcause it to operate prematurely. .' %Page NOTICE The TYCO Series TY-FRB Sprinklers described herein must Me installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance Of these devices. The owner is responsible for main- taming their fire protection . system and devices -in proper operating con- dition. Contact the installing contrac- tor or produOt manufacturer With any questions. Sprinkler identification Number (SIN) TY313 .....Upright 5.6K, 112NPT .Pendent 5.6K, 1/2'NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (121 bar) 250 psi (17.2 barV The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato-ries, Inc. (DL). Discharge Coefficient K=5.6 GPM/psi (80,6 UPM/bar ½) Temperature Rating Refer to Table A Finishes Sprinkler 'Refer to Table B RecesedEscutcheott White Coated, Black Coated, Chrome Plated, or 8iass Plated Physical Characteristics Frame ....................... . ..... :Bronze Button ......................Brass/Copper Sealing Assembly . Stainless Steel w/TEFLON Bulb ................................. Glass, Compression Screw .................Bronze. Deflector ..........................Bronze JULY 2017 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flOw.. Design Criteria The TYCO Series TY-FRB 56 K-factor, Upright (TY3I3) and Pendent (TY323 Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. TFPI72 -r/frrV TFPI72 Page 2.of 4 Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread, connections per ISO 7-1 4 - Bulb indicated on Deflector, can be provided on special request. 5 - Compression Screw 'ESCUTCHEON PLATE 1/2' 7/16 (11,1 mm) 6 - Deflector* DEFI.ECTOR * SEATING SURFACE NPT** 'NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 7/16 (11,1 mm) NOMINAL MAKE-IN (50,: 2- (50,8 mm) , (3,m I WRENCH IFM _N/ '9 _J 1/2' NPT DEFLECTOR* 2-7/8"(73,Omm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE'l SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6K-,FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation The TYCO Series TWFRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. -General Instructions Do not install any bulb:-type, sprinkler if the bulb is cracked or there is a loss of liquid fromthebu'lb. With the sprin- 'lder'held horizontally, a-small ài.rbubbie shoUld be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135F (S7°C), and: 3132' inch (2,4 mm) for the 286°F (141°C) tem- perature ratings. A Ieaktight 1/2, inch NPT sprinkler joint should be obtained by applying a 'minimum to maximum torque of 7 to 14 fL-Ibs:, (,5, to 19',O' Nm. Higher levels, of torque can distort the sprinkler Inlet with consequent leakage or impairment -of 'the-sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate, by under-- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent'Sprinklers The Series TY-,FRB upright and Pendent Sprinklers must be: installed 'in accordance with the following instructions. .Step i..lnstafl.Pendent sprinklers in the pendent position. Install upright spnn- klërs in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence-to Figure 1; apply the-W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft-lbs. (9,5 to .15,0 'Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinkler's must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or 'Style 20 Mounting Plate 'over the sprinkler threads, and with pipe-thread sealant applied: to the pipe threads,,' hand:-tighten the sprinkler into the sprinkler fitting. ,.Step Z. Tighten the 'sprinkler into the sprinkler 'fitting using only the 'W-Type 7 Recessed: Sprinkler Wrench (Figure 3).. With reference to Figure 1, apply. the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers'7 to 14 ft.-Ibs. (9,5 to 19,0 Nm. Step C. After ceiling installation and finishing; slide on' the Style '15' or Style' 20 'Closure over the Series TY-FRB Sprinkler and push the Closure over the, MountingPlate until its flange:cornes.in contact with the ceiling. WRENCHRECESS (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER' WRENCHING AREA FIGURE 3 W.TYPE7RECESSED SPRINKLER WRENCH TFPI.72 Page 3 of 4 Care and Maintenance The TVCO SeiiesTY-FRB, 5.6K-factor, Uptight (TY313) and Pendent (TY323) Sprinklers must e maintained and ser- viced in accordance with this section. Sefore.ctosirg afire ;protection.system main control valve ior maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may he affected by this action. Absence of the outer piece of an escutcheon, which is used to cover• a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently, dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion, must be replaced Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, shouldbe replaced ifthey cannot be completely cleaned by wiping The sprinkler with :a cloth or thy brushing it with a sdftbristlebrush. Care must be exercised to avoid damage to. the sprinklers before, during, and after installation. Sprin- klers damaged thy dropping, striking, ' wrenchtwist/sllppage, orthelike, must be replaced. Also, replace any sprin- kler that has ,a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the ,." inspection; testing,and..maintenanceof their fire protection system and devices in compliance with this document, as well as with the applicable Standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), inaddition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained thy .a qualified linspec- tion Service in accordance with local requirements and/or nationalcodes. 2-7/8' DIA (73,0 mm) 2-1/4'DlA. FACE OF [ (57,2 mm) SPRINKLER FITTING I L FLUSH 3/8±5116' (95±7.i9;n /\_ MOUNTING 1/8, SURFACE CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TY-FRB PLATE 3/4"(19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (T"23) WITH TWO PIECE 518 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 27/80 DIA. (73,0 mm) FACE-OF SPRINKLER L. 2-1/4' DIA. FITTING (57,2 mm) (7964)\ 1/2'(12,7mm) _1 FLUSH MOUNTING /' 1/8' j SURFACE/ - \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TY-FRB PLATE 7/8' (22,2 inm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1I2INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON Recessed-Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish,,. P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N; 56'000-6=387 Specify: W-Type 7 Sprinkler Wrench, PIN 56-850-4-001 Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or f'endent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N. (specify, referto-Table. Llmited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. Whenpiacing an order, indicate the full product name and Part Number 3. TFPI72 Page 4 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED 1 POLYESTERC 135°F (57°C) Orange UPRIGHT (TY313) 155°F (68°C) Red 175°F (79°C) Yellow and 1,-2,3,4,5,6 PENDENT (TV323) 200°F(93°C) Green 286°F (141°C) Blue 5.6 1/2" NPT _______________ 135°F (57°C) Orange RECESSED PENDENT (TY313) Figures 4a and 5b 1,2,3,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories. Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact TYCO Fire Protective Products, Enschede, Netherlands, TeL 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. WherePolyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15 (1/2" NPT) 5/8' Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2" NPT) 1/2' Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6K-FACTOR SPRINKLERS -xxx SPRINKLER 1 TEMPERATURE FINISH 1 RATINGS P/N*77_X(X_ SIN L370 5.61< UPRIGHT (1/2- NPT) TY313 371 5.61< PENDENT (1/2' NPT) 1Y323 Use suffix "I' forASOJ-1 connection; for example, 77-370-4-175-I NATURAL BRASS PURE WHITE (RAL9010)** POLYESTER SIGNAL WHITE (RAL9003), POLYESTER JET BLACK RAL9005 POLYESTER 9 CHROME PLATED 135 1359F (57°C) 155 155°F(68°C) 175 175-F (79-C) 200 200°F (93°C) 286 286°F (141°C) Eastern Hemisphere sates only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION GLOBAL HEADQUARTERS I 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright.@2017 Tyco Fire:Products,.LP. Alirights reserved t Ca TEFLON is a registered trademark of DuPont Fire Protection Products