Loading...
HomeMy WebLinkAboutDWG 501-7A; DEV 2017-0034; CARR RESIDENCE; 01-04GRADING NOTES (IN ADDITION TO THE REQUIREMENTS OF CHAPTER 15.16 OF THE CARLSBAD MUNICIPAL CODE.) 1. THIS PLAN SUPERSEDES ALL OTHER PLANS PREVIOUSLY APPROVED BY THE CITY OF CARLSBAD REGARDING GRADING SHOWN ON THIS SET OF PLANS. 2. APPROVAL OF THIS PLAN DOES NOT LESSEN OR WAIVE ANY PORTION OF THE CARLSBAD MUNICIPAL CODE, RESOLUTION OF CONDmONAL APPROVAL, CITY STANDARDS OR OTHER ADDmONAL DOCUMENTS LISTED HEREON AS THEY MAY PERTAIN TO THIS PROJECT. THE ENGINEER IN RESPONSIBLE CHARGE SHALL REVISE THESE PLANS WHEN NON-CONFORMANCE /S DISCOVERED. 3. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER OR ENGINEER-OF- WORK FROM RESPONSIBILITY FOR THE CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. ALL PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 4. A RIGHT-OF-WAY PERMIT FROM THE CITY ENGINEER WILL BE REQUIRED FOR ANY WORK IN THE PUBLIC RIGHT OF WAY. PRIOR TO PERMIT ISSUANCE, A CERTIFICATE OF INSURANCE AS WE'LL AS ADDmONAL INSURED ENDORSEMENT MUST BE FILED NAMING THE CITY OF CARLSBAD AS AN ADD/T10NAL INSURED ON 71-IE PERMITTEE'S POLICY IN THE MINIMUM AMOUNT OF $1,000,000.00 FOR EACH OCCURRANCE OF LIABILITY. T/;(E INSURANCE COMPANY 00/TING THE POI ICY MUST HA VE A RA 71NG OF "A-OR BETTER AND A SIZE CATEGORY OF CLASS VII OR BETTER AS ESTABLISHED BY "BESTS" KEY RA TING GUIDE. 6. NO WORK SHALL BE COMMENCED UNTIL ALL PERMITS HA VE BEEN OBTAINED FROM THE CITY AND OTHER APPROPRIATE AGENCIES. 7. APPROVAL OF THESE PLANS BY THE CITY ENGINEER DOES NOT AUT1-/0RIZE ANY WORK OR GRADING TO BE PERFORMED UNTIL THE PROPERTY OWNER'S PERMISSION HAS BEEN OBTAINED AND A VALID GRADING PERMIT HAS BEEN ISSUED. 8. NO REVISIONS W,LL BE MADE TO T/-IESE PLANS WITHOUT 71-IE WRITTEN APPROVAL OF 71-IE CITY ENGINEER, NOTED W,TH/N THE REVISION BLOCK, ON 71-IE APPROPRIATE SHEET OF THE PLANS AND THE TITLE SHEET. 9. ORIGINAL ORA W1NGS SHALL BECOME THE PROPERTY OF THE CITY UPON BEING SIGNED BY THE Cl TY ENGINEER. 10. 71-IE ORIGINAL DRAWING SHALL BE REVISED TO REFLECT AS-BUILT CONDITIONS BY THE ENGINEER-OF-WORK PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE CITY. 11. ACCESS FOR ARE AND OTHER EMERGENCY VEHICLES SHALL BE MAINTAINED TO THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. 12. WHERE TRENCHES ARE WITHIN CITY EASEMENTS, A SOILS REPORT COMPRISED OF: (A) SUMMARY SHEET, (B) LABORATORY WORK SHEETS AND (C) COMPACTION CURVES, SHALL BE SUBMITTED BY A PROFESSIONAL ENGINEER OF THE STA TE OF CALIFORNIA, PR/NC/PALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. THE SO/LS REPORT I\ILL BE SUBMITTED TO THE CITY ENGINEER/NG INSPECTOR WITHIN TWO WORKING DAYS OF THE COMPLETION OF FIELD TESTS. 13. A SOILS COMPACT10N REPORT AND COMPLIANCE VER/FICA TION REGARDING ADHERENCE TO RECOMMENDA T10NS OUTLINED IN THE SOILS REPORT IS REQUIRED PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL CONTROLLED GRADING SHALL BE DONE UNDER THE DIRECT10N OF A PROFESSIONAL ENGINEER OF THE STA TE OF CALIFORNIA PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS. ALL FILL OR FUTURE FILL AREAS SHALL BE CONSTRUCTED IN ACCORDANCE 111TH TH£ CITY OF CARLSBAD STANDARD SPECIF/CA T10NS AND THE • EARTHWORK SPECIF/CATIONS " ATTACHED TO THE PRELIMINARY SOILS INVEST1GA 110N. DAILY FIELD COMPACTION REPORTS WILL 8£ SUBMITTED TO THE PROJECT INSPECTOR. 14. A fflECONSTRUCTION MEETING SHAil BE HEl D AT TH£ SITE PRIOR TO TH£ BEGINNING OF WORK AND $HAIL BF ATTFNDED BY All REPRFSENTADYfS RESPONSIBLE FOR CONSTRUCTION, INSPECTION. SUPERVISION. TEST1NG AND ALL OTHER ASP£C7S Of THE WORK, THE CONTRACTOR SHALL REQUEST A PRECONSTRUCT10N MEETING BY CALLING THE INSPECTION LINE AT (760) 438-3891 AT LEAST FIVE(5) WORKING DAYS PRIOR TO START1NG CONSTRUCTION. THE CONTRACTOR WILL THEN BE CONTACTED BY 71-/E PROJECT INSPECTOR TO COORDINATE A DA TE AND TIME FOR THE PRECONSTRUCTION MEETING. APPROVED ORA WINGS MUST BE AVAILABLE PRIOR TO SCHEDULING. THE GRADING PERMIT I\ILL 8£ PROVIDED BY THE PROJECT INSPECTOR AT THE MEETING. 15. Al I tNSPfCDON REQUESTS OTHER THAN FOR PRECONSTRUC110N MEETING W/1 l BE MAD£ BY CAIi /NG IH£ ENG/NEERING 24-HOlJR INSPECTION RFQIJFST llNE AT (760) 438-3891. INSPECTION REOUEST MUST BE RECEIVED PRIOR TO 2; oo P,M. ON THE DAY BEFORE THE INSPECTION IS NEEDED. INSPECTIONS WILL BE MADE THE NEXT WORK DAY UNLESS YOU REQUEST OTHERWISE. REQUESTS MADE AFTER 2: 00 P.M. WILL BE SCHEDULED FOR TWO FULL WORK DAYS LATER. 16. THE O'NNER AND/OR APPLICANT THROUGH THE DEVELOPER AND/OR CONTRACTOR SHALL DESIGN, CONSTRUCT AND MAINTAIN ALL SAFETY DEVICES, INCLUDING SHORING, AND SHALL BE SOLELY RESPONSIBLE FOR CONFORMING TO ALL LOCAL, STATE ANO FEDERAL SAFETY AND HEALTH STANDARDS, LAWS AND REGULAT10NS. 17. THE CONTRACTOR SHALL CONFORM TO LABOR CODE SECTION 6705 BY SUBMITTING A DETAIL PLAN TO THE Cl TY ENGINEER AND /OR CONCERNED AGENCY SHOWING THE DESIGN OF SHORING, BRACING SLOPING OR OTHER PROVISIONS TO BE MADE OF WORKER PROTECT10N FROM THE HAZARD OF CA VINO GROUND DURING THE EXCAVA 110N OF SUCH TRENCH OR TRENCHES OR DURING THE PIP£ INSTALLATION THEREIN. THIS PLAN MUST BE PREPARED FOR ALL TRENCHES FIVE FEET (5') OR MORE IN DEPT/-/ AND APPROVED BY THE CITY ENGINEER AND/OR CONCERNED AGENCY PRIOR TO EXCAVATION. IF THE PIAN VAR/ES FROM THE SHORING SYSTEM STANDARDS ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS. TITLE 8 CALIFORNIA AOMINISTRA TIVE COD£. THE PLAN SHALL BE PREPARED BY A REGISTERED £NG/NEER AT THE CONTRACTORS EXPENSE, A COPY OF THE OSHA f§8~~~~8~. PERMIT MUST 8£ SUBMITTED TO THE INSPECTOR PRIOR TO 18. NO BLASTING SHALL BE PERFORMED UNTIL A VALID BLASTING PERMIT HAS BEEN OBTAINED FROM THE CITY OF CARLSBAD. SUBMIT APPL/CATION FOR BLASTING PERMIT WE'LL IN ADVANCE OF THE SCHEDULING OF BLASTING OPERATIONS. 19. IF ANY ARCHAEOLOGICAL RESOURCE$ AR£ DISCOVERED WITHIN ANY WORK AREA DURING CONSTRUCTION, OPERATIONS WILL CEASE !MMEDIA TELY. AND THE PERM/TT££ WILL NOTIFY THE CITY ENGINEER. OPERA T10NS WILL NOT RESTART UNT1L THE PERM/TT££ HAS RECEIVED WRITTEN AUTHORITY FROM THE CITY ENGINEER TO 00 SO. 20. ALL OPERA T10NS CONDUCTED ON THE SITE OR ADJACENT THERETO, INCLUDING WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR OPERATION OF TRUCKS, EARTHMOVING EQUIPMENT, CONSTRUCTION EQUIPMENT ANO ANY OTHER ASSOC/A TED GRADING EQUIPMENT SHALL 8£ LIMITED TO THE PERIOD BETWEEN 7: 00 A.M. AND 8: 00 P.M. EACH DAY, MONDAY THRU FRIDAY ANO NO EARTHMOVING OR GRADING OPERATIONS SHALL BE CONDUCTl:."D ON Wf:EKENDS OR HOLIDAYS. (A LIST OF CITY HOLIDAYS /S AVAILABLE AT THE ENGINEER/NG DEPARTMENT COUNTER.) 21. ALL OFF-SITE HAUL ROUTES SHALL BE SUBMITTED BY THE CONTRACTOR TO THE CITY ENGINEER FOR APPROVAL TWO FULL WORKING DAYS PRIOR TO BEGINNING OF WORK. 22. IMPORT MATERIAL SHALL BE OBTAINED FROM, AND WASTE MATERIAL SHALL BE DEPOSITED AT, A SITE APPROVED BY THE CITY ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEBRIS OR DAMAGE OCCURRING ALONG 71-1£ HAUL ROUTES OR ADJACENT STREETS AS A RE:SUL T OF THE GRADING OPERATION. 23. BRUSH SHALL BE REMOVED ONLY I\ITHIN THE AREA TO BE GRADED. NO TREES ARE TO BE REMOVED UNLESS SPECIF/CALLY NOTED ON THE PLAN. 24. ALL AREAS SHALL 8£ GRADED TO DRAIN. GRADING RESUL T1NG IN THE PONDING OF WATER IS NOT PERMITTED. ALL EAR THEN SWALES AND DITCHES SHALL HA VE A MINIMUM ONE PERCENT SLOPE. 25. THESE PLANS ARE SUBJECT TO A SIGNED AND APPROVED SWPPP AND/OR SET OF EROSION CONTROL PLANS. EROSION CONTROL SHALL BE AS SHOWN AND AS APPROVED BY TH£ CITY ENGINEER OR AS DIRECTED BY THE PROJECT INSPECTOR. 26. ALL SLOPES SHALL BE TRIMMED TO A FINISH GRADE TO PRODUCE A UNIFORM SURFACE AND CROSS SECTION. THE SITE SHALL 8£ LEFT IN A NEAT AND ORDERLY CONDIT10N. ALL STONES, ROOTS OR OT/-IER DEBRIS SHALL 8£ REMOVED ANO DISPOSED OF AT A SITE APPROVED OF BY THE CITY ENGINEER. 27. ALL SLOPES SHALL BE /RR/GA TED, STABILIZED, PLANTED AND/OR HYDROSEEDED WITHIN TEN (10) DAYS OF THE T1ME WHEN £M1i SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 28. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE CITY OF CARLSBAD LANDSCAPE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT, DRAI\ING NO. ____ , AND/OR AS DIRECTED BY THE CITY ENGINEER OR PLANNING DIRECTOR. !'OG PROJECT No.'185824-5 OAT£: 5-9-17 29. THE OWNER/APPLICANT SHALL INSURE THAT ALL CONTJACTORS SHALL COORDINATE 1HE WORK OF THESE GRADING PLANS WITH THAT SHOW/\ ON BOTH THE LANDSCAPE AND /RR/GA 110N PLANS AND THE IMPROVEMENT PLANS AS REQUIRED FOR THIS WORK IN ACCORDANCE WITH 7HE LANDSCAPE MANUAL lME REQUIREMENTS. 30. WHERE AN EXIST1NG PIPE LINE IS TO BE ABANDON£, AS A RESULT OF THE GRADING OPERA 110N, IT SHALL BE REMOVED WITH/II TWENTY FEET OF BUILDING OR STREET AREAS AND REPLACED WITH PROPERLY CCMPACTED SOILS. IN 01HER AREAS THE PIPE WILL 8£ PLUGGED WITH CONCRETE OR REMOVED AS APPROVED BY THE CITY ENGINEER. 31. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING FACILITIES ( ABOVE GROUND AND UNDER GROUND ) 'MTHIN THE PROJECT SITE SUFFICIENTLY AHEAD OF GRADING TO PERMIT THE REVISION OF iH£ GRADING PLANS IF IT IS FOUND THAT TH£ ACTUAL LOCA T10NS ARE IN CON/l/CT WITH THE PROPOSED WORK. 32. THE CONTRACTOR SHALL NOTIFY AFFECTED UTILITY ~OMPANIES (SEE BELOW) AT LEAST 2 FULL WORKING DA Y.S' PRIOR TO STARTNG GRADING NEAR THEIR FACILITIES AND SHALL COORDINATE 1HE WORK WITH A WMPANY REPRESENTA T1VE. UNDERGROUND SERVICE ALERT (800)422-4133 SDG&E (800)411-7343 AT&T (800)892-0123 T1ME WARNER CABLE {760)438-7741 COX COMMUN/CATIONS (619)262-1122 CITY OF CARLSBAD(STREETS & STORM DRAIN) (760)434-2980 'CITY OF CARLSBAD(SEWf:R,WATER & RECLAIMED WATER) (760)438-2722 'SAN DIEGUITO WATER DISTRICT (760)633-2650 'LEUCADIA WASTEWATER DISTRICT (760)753-0155 'VALLECITOS WATER DISTRICT (760)744-0460 'OL/VENHAIN WATER DISTRICT (760)753-6466 'BUENA SANITATION DISTRICT (780)726-1340 x/330 *AS APPROPRIATE 33. PERMIT COMPLIANCE REQUIREMENTS: A. Fi CONTROLL R G -THE APPL/CAN, HIRES A CIVIL ENGINEER, SOILS ENGINEER, AND OR GEOLOGIST TO GIVE TECHNICAL ADVICE, OBSERVE AND CONTROL THE WORK IN PROGRESS {15.16.120 A.BJ CARLSBAD MUNICIPAL COD£. 8. PRIOR TO f/NAL APPROVAL Of A GRAD/NG 0ERMIT -THE FOLLOWING REPORTS MUST BE SUBMITTED TO TH£ CITY ENGINEER VIA THE PROJECT INSPECTOR { 15.16.120 A.1 OJ CARLSB~D MUNICIPAL CODE: (1) FINAL REPORT BY SUPERVISING GRAD/Nii ENGINEER STA TING ALL GRADING IS COMPLETE. ALL EROSION CONTROL, SLOPE PLANTING AND /RR/GA TION ARE INSTALLED IN CONFORMANCE WITH CITY COD£ AND THE APPROVED PLANS ( OBTAIN SAMPLE OF COMPLIANCE LETTER FROM CITY ENGINEER/NG DEPAR1UENT). (2) AS-BUILT GRADING PLAN. (3) REPORT FROM THE SOILS ENG/fi£ER, WHICH INCLUDES RECOMMENDED SOIL BEARING CAPACITTES, A STATEMENT AS TO THE EXPANSIVE QUALITY OF 1HE SOIL, AND SUMMARIES OF FIELD AND LABORATORY TESTS. 7HE REPORT SHALL ALSO INCLUDE A STATEMENT BY THE SOLS ENGINEER THAT THE GRADING WAS DONE IN ACCORDANCE Wl'H THE REQUIREMENTS AND RECOMMENDA T10NS OUTLINED IN THE PRELIMINARY SOILS REPORT AND ANY SUPPLEMENTS THERETO. ( 4) REPORT 1111H AS-BUil T GEOLOGIC PIAN, IF REQUIRED BY 71-1£ CITY. 34. UNLESS A GRADING PERMIT FOR THIS PROJECT I, ISSUED WITHIN ONE (1) YEAR AFTER TH£ CITY ENGINEER'S APPROVAL, THESE PLANS MAY 8£ REQUIRED TO BE RESUBMITTED FOR PLANCHECK. PLANCHECK FEES WILL BE REQUIRED FOR ANY SUCH RECHECK. 35. IN ACCORDANCE WITH THE CITY STORM WATER STANDAR,S, ALL STORM DRAIN INLETS CONSJRUCTED BY 7HIS PLAN SHALL INCLUDE 'STENCI.S" BE ADDED TO PROHIBIT WASTEWATER DISCHARGE: DOWNSTREAM. STENCILS S!ALL 8£ ADDED TO THE SATISFACTION OF THE CITY ENGINEER. "DECLARATION OF RESPONSIBLE CHARGE" I HEREBY DECLARE 1HA T I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HA VE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND T/-IAT THE CHECK OF PROJECT DRAWINGS #10 SPECIFICAT10NS BY THE CITY OF CARLSBAD DOES NOT RELIEVE ME, AS ENGNEER OF WORK, OF MY RESPONSIBILIT1ES FOR PROJECT DESIGN. FIRM: ENGINEERING DESIGN GROUP ADDRESS: 2121 MON71£L ROAD CITY, STATE:~~M!!'~~Y~L~---- 7ELEPHON£/,: i-JJ.J""!-~='""-----;,''---------- BY: --'-'S,,-<'1=.,,f,-.;d;---='---,. DATE: 0-20-11 RI RIST R.C.E. 0.:=~,;_.=65=1=22~----,---,----- REGISTRAT10N EXPIRAT10N DATE:-~9/,~3=0/~1~7 ___ _ SOILS ENGINEER'S CERTIFICATE onss,0 \~ E. 1?1 No, 65122 E>:p, 09/30/2017 i 1/, I, ERIN RIST, A REGISTERED CIVIL ENGINEER OF THE STA TE CF CALIFORNIA, PRINCIPALLY DOING BUSINESS IN THE FIELD OF APPLIED SOILS MECHANICS HEREBY CERT1FY THAT A SAMPLING AND STUDY OF THE SOIL CONDIT10NS PREVALENT ///THIN THIS SITE WAS MADE BY ME OR UNDER MY DIRECTION ON JULY 15, 2016. TWO CO?IES OF THE SOILS REPORT COMPILED FROM IS sru ' TH MY RECOMMENDATIONS, HAS BEEN SUBMITTED TO THE OFFICE E CIT:r ENGINE R. SIGNED: - RC£ NO.: DA TE: __ ____.,,G--_"2-c...0_·.cn_c.__ _______ _ LICENSE: EXP/RATION DA TE: 9_/3=0-1~1 ~7 __ _ OWNER'S CERTIFICATE No. 65122 E:xp, 09/30/il017 WE' HEREBY CERT1FY THAT A REGISTERED SOILS ENGINEER QA GEOLOGIST HAS BEEN OR WILL BE RETAINED TO SUPERVISE OVER-ALL GRADING ACT1VIJY AND ADVISE ON THE COMPACT10N AND STABILITY OF THIS SITE. IF THIS PROJEGT/tJE:VELOPMENT IS SUBJECT TO A STA TE -REGULA TED SWPPP, ~ ALSO AGREE A QUALIFIED SWPPP PRACT1110NER (QSP) HAS BEEN OR WILL BE RETAINED TO SUPERVISE /MPLEMENTAffON OF TH£ SWPPP IN ACCORDANCE WITH THE CALIFORNIA CONSTRUCT10N ORDER A.VD MUNICIPAL PERMIT, LA TEST VERSION. &:J ERIC CARR ~&?0( @Ad KIMBERLY cXRR DATE <p-e.i..-/7 DATE SOURCE OF TOPOGRAPHY TOPOGRAPHY SHOWN ON THESE PLANS WAS GENERA TEO BY FIELD SURVEY METHODS FROM INFORMATION GATHERED ON 6/9/2016, BY HOPWOOD LAND SURVEYING, PHONE NO. 760. 738.9636. TOPOGRAPHY SHOWN HEREON CONFORMS TO NATIONAL MAP ACCURA,;Y STANDARDS. PROJECT LOCATION THIS PROJECT IS LOCATED WITHIN ASSESSORS PARCEL NUMB£R(S} 205-011-08 7HE CALIFORNIA COORDINATE INDEX OF THIS PROJECT IS: 358-1665 EROSION CONTROL NOTES 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT ERIC CARR AT (760) 434-9270 2. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL T1MES DURING THE RAINY SEASON. ALL NECESSARY MATERIALS SHALL 8£ STOCKPILED ON SITE AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS EMINENT. 3. FOR PROJECTS COVERED BY STA TE SWPPP /Y,VID, IN ACCORDANCE WITH THE CONSTRUCT10N ORDER ISSUED BY 1HE CALIFORNIA REGIONAL WATER QUALITY CONJROL BOARD, THE QUALIFIED SWPPP PRACT1TIONER (QSP) SHALL UPDATE AND MAINTAIN THE WATER POLLUTION CONTROL (WPC) PLAN TO ADDRESS UPDATED SITE CONDITIONS OF THE PROJECT. THE UPDATED WPC PLAN AND UPDATED SWPPP SHALL BE KEPT AT 7HE PROJECT SITE AND MAO£ AVAILABLE TO THE CITY INSPECTOR. ADDITIONAL CONSTRUCTION BMP'S BEYOND THE ORIGINAL APPROVED SWPPP SHALL 8£ PROVIDED It) ADDRESS SITE COND/T10NS NOT ANTIC/PA TED. THE QSP SHALL REPORT BMP DEFICIENCIES TO 1HE CITY INSPECTOR. 7HE QSP SHALL OBTAIN APPROVAL FROM THE QUALIFIED SWPPP DEVELOPER AND THE CITY INSPECTOR REGARDING ANY SIGNIFICANT CHANGES TO BMP DEPLOYMENT. 4. THE CONTRACTOR SHALL RESTORE: ALL EROSION CONTROL DEVICES TO WORKING ORDER TO THE SA TISFACT10N OF THE CITY ENGINEER AFTER EACH RUN-OFF PRODUCING RAINFALL. 5. 71-1£ CONTRACTOR SHALL INSTALL ADDmONAL EROSION CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 6. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATERS CREA TE A HAZARDOUS CONDITION. 7. ALL EROSION CONTROL MEASURES PROVIDED PER THE APPROVED SWPPP AND/OR EROSION CONTROL PLAN SHALL BE INCORPORATED HEREON. 8. GRADED AREAS AROUND THE PROJECT PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPE AT THE CONCLUSION OF EACH WORKING DAY. 9. ALL REMOVABLE PROTECTIVE DEVICES SHOWN SHALL BE IN PLACE: AT THE END OF EACH WORKING DAY WHEN TH£ FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER EACH RAINFALL. 10. ALL GRAVEL BAGS SHALL BE BURLAP TYPE 111TH 3/4 INCH MINIMUM AGGREGRATE. 11. SHOULD GERMINATION OF HYDROSEEOEO SLOPES FAIL TO PROVIDE EFFECT1VE COVERAGE OF GRADED SLOPES (90% COVERAGE) PRIOR TO NOVEMBER 15, THE SLOPES SHALL BE STABILIZED BY PUNCH STRAW INSTALLED IN ACCORDANCE 111TH SECT10N 35.023 OF TH£ EROSION AND SEDIMENT CONTROL HANDBOOK OF 1H£ DEPARTMENT OF CONSERVA 110N, STA TE: OF CALJFORNIA. TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION ALL PERMANENT AND TEMPORARY EROSION CONJROL PLANTING AND /RR/GA TION SHALL BE INSTALLED AND MAINTAINED AS REQUIRED IN SECTION 212 OF THE STANDARD SPECIF/CA T10NS AND THE FOLLOWING: A. HYDROSEEDING SHALL 8£ APPLIED TO: 1. ALL SLOPES THAT ARE GRADED IS: 1 (HORIZONTAL TO VERTICAL) OR STEEPER WHEN THEY ARE: a. THREE FEET · OR MORE IN HEIGHT AND ADJACENT TO A PUBLIC WALL OR STREET. b. ALL SLOPES 4 FEET OR MOR£ IN HEIGHT. 2. AREAS GRADED FLATTER THAN 6: 1 WHEN ANY OF THE FOLLOWING CONDmONS EXIST: a. NOT SCHEDULED FOR IMPROVEMENTS(CONSTRUCTION OR GENERAL LANDSCAPING) WITHIN 60 DAYS OF ROUGH GRADING. b. IDENTIFIED BY THE PARKS AND RECREAT10N DIRECTOR AS HIGHLY VISIBLE: TO 1HE PUBLIC. c. HA VE ANY SPECIAL CONDITION IDENT1FIED BY THE CITY ENGINEER THAT WARRANTS IMMEDIATE TREA lMENT. B. HYDROSEEDED AREAS SHALL BE /RR/GA TED IN ACCORDANCE WITH THE FOLLOWING CRITERIA: 1. ALL SLOPES THAT ARE GRADED 6: 1 OR STEEPER AND THAT ARE: a. THREE TO EIGHT FEET IN HEIGHT SHALL Bf. /RR/GA TED BY HAND WATERING FROM QUICK COUPLERS/HOSE BIBS OR A CONVENT10NAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROVIDING 100% COVERAGE. b. GREATER THAN 8 FEET IN HEIGNT SHALL BE WATERED BY A CONVENTIONAL SYSTEM OF LOW PRECIPITATION SPRINKLER HEADS PROVIDING 100% COVERAGE. 2. AREAS SLOPED LESS THAN 6: 1 SHALL BE /RR/GA TED AS APPROVED BY THE CITY ENGINEER, PRIOR TO HYDROSEEDING. TH£ DEVELOPER SHALL SUBMIT A PROPOSED SCHEME TO PROVIDE /RR/GA TION TO THE CITY ENGINEER. THE PROPOSAL SHALL BE SPECIFIC REGARDING THE NUMBERS, TYPES AND COSTS OF THE ELEMENTS OF THE THE PROPOSED SYSTEM. 3. /RR/GA TION SHALL MAINTAIN TH£ MOISTURE LEVEL OF THE SOIL AT THE OPT1MUM LEVEL FOR THE GROWTH OF TH£ HYDROSEEDED GROWTH. C. HYDROSEEDING MIX SHALL CONSIST OF ALL OF THE FOLLOWING: 1. SEED MIX SHALL CONSIST OF NO LESS THAN: a. 20 lbs. PER ACRE OF ROSE CLOVER b. 20 lbs. PER ACRE OF ZORRO FESCUE c. J lbs. Pl:R ACRE OF E SCHOOL CIA CALIFORNICA d. 4 tbs. PER ACRE OF ACHILLEA MILLEFOLIA e. 3 lbs. PER ACRE: OF AL YSSUM {CARPET OF SNOW) f. 1/2 lb. PER ACRE OF DIMORPHOLECA g. ITEMS c,d,e, AND f OF THIS SUBSECTION MAY 8£ OMITTED ON LOCATIONS WHERE THE AREA BEING HYDROSEEDED IS NOT VISIBLE: FROM EITHER A PUBLIC STRE£T OR RESIDENTIAL STRUCJURES. h. ITEM a OF THIS SUBSECT10N MUST BE INOCULATED WITH A NITROGEN FIXING BACTERIA AND APPLIED DRY EITHER BY DRILLING OR BROADCAST1NG BEFORE HYDROSEEDING,. I. ALL SEED MATERIALS SHALL BE TRANSPORTED TO THE JOBS/TE IN UNOPENED CONTAINERS 111TH THE CALIFORNIA DEPARTMENT OF FOOD AND AGRICUL'/URE CERTIFICATION TAG ATTACHED TO, OR PRINTED ON SAID CONTAINERS. ). NON-PHYTO-TOX/C WETTING AGENTS MAY BE ADDED TO 1HE HYDROSEED SLURRY AT THE DISCRE710N OF THE CONTRACTOR. 2. TYPE 1 MULCH APPLIED AT THE RA TE OF NO LESS THAN 2000 lbs PER ACRE. TYPE 6 MULCH (SJRAW) MAY BE SUBSTITUTED, ALL OR PART. FOR HYDRAULICALLY APPLIED FIBER MATERIAL. WHEN STRAW IS USED IT MUST BE ANCHORED TO TH£ SLOPE BY MEGHAN/CALLY PUNCHING NO LESS THAN 50% OF THE STRAW INTO THE SOIL. 3. FERTILIZER CONSIST1NG OF AMMONIUM PHOSPHATE SULFATE, 16-20-0, WITH 15% SULPHUR APPLIED AT THE RA TE OF 500 lbs. PER ACRE. D. AREAS TO 8£ HYDROSEEDED SHALL 8£ PREPARED PRIOR TO HYDROSEEDING BY: 1. ROUGHENING THE SURFACE TO 8£ PLANTED BY ANY OR A COMB/NATION OF: a. TRACK WALKING SLOPES STEEPER 1HAN 6: 1 b. HARROWING AREAS 6: 1 OR FLATTER 7HA T ARE SUFFICIENTLY FRIABLE. c. RIPPING AREAS THAT WILL NOT BREAK UP USING ITEMS a OR b ABOVE. 2. CONDITION/NG THE SOILS SO THAT IT IS SUITABLE FOR PLANTING BY: a. ADJUSTING THE SURFACE SOIL MOISTURE TO PROVIDE A DAMP BUT NOT SA JURA TED SEED BED. b. THE ADD/T10N OF SOIL AMENDMENTS, PH ADJUSTMENT, LEACHING COVERING SALINE SOILS TO PROVIDED VIABLE COND/T10NS FOR GROWTH. £. HYDROSEEDED AREAS SHALL BE MAINTAINED TO PROVIDE A VIGOROUS GROWTH UNTIL THE THE PROJECT IS PERMANENTLY LANDSCAPED OR, FOR AREAS WHERE: HYDROSEEOING IS THE TH£ PERMANENT LANDSCAPING, UNTIL THE PROJECT IS COMPLETED AND ALL BONDS RELEASED. OJECT SITE WORK TO BE DONE THE GRADING WORK SHALL CONSIST OF THE CONSTRUCT10N OF ALL CUTS AND FILLS, REMEDIAL GRADING, DRAINAGE: FACIL/T1ES, EROSION CONTROL FACILIT1ES, AND PLANT1NG OF PERMANENT LANDSCAPING AND PREPARATION OF AS-BUILT GRADING PLANS, AS-BU/LT G£0LOG/C MAPS AND R£POR7S, ALL AS SHOWN OR REQUIRED ON THIS SET OF PLANS AND 1HE CITY STANDARDS, SPECIF/CA T10NS, REQUIREMENTS, RESOLUTIONS AND ORDINANCES CITED ON THESE PLANS,. THE GRADING WORK SHALL BE PERFORMED IN ACCORDANCE: 'MTH THE FOLLOWING DOCUMENTS, CURRENT AT THE T1ME OF CONSTRUCTION, AS DIRECTED BY THE CITY ENGINEER. 1. CARLSBAD MUNICIPAL CODE 2. CITY OF CARLSBAD ENGINEERING STANDARDS J. THIS SET OF PLANS 4. RESOLUTION NO. NIA DA TED NIA 5. THE STANDARD SPECIF/CATIONS FOR PUBLIC WORKS CONSTRUCT10N (GREEN BOOK). 6. SOILS REPORT AND RE:COMMENDA T10NS BY ENGINEERING DESIGN GRQUP DA TED JULY 15, 2016 .,..__.,._ ,-..,-.. ~ VICINITY MAP .1 7. THE SAN DIEGO REGIONAL STANDARD ORA WINGS AND AS MAY 8£ MODIFIED BY THE CITY OF CARLSBAD STANDARDS • AQUA HEDIONDA LAGOON NOT TO SCALE 8. CALIFORNIA COASTAL COMMISSION DEVELOPMENT PERMIT CONDmONS INDEX OF SHEETS 1. COVER SHEET -NOTES, WORK TO BE DONE 2. MINOR GRADING PLAN 3&4. STORMWA TER POLLUT10N P,'?EVENTJON PLAN(SWPPP) -EROSION CONTROL PLAN LEGAL DESCRIPTION LOT 8 IN BLOCK "H" OF PALISACES, IN THE CITY OF CARLSBAD, COUI/TY OF SAN DIEGO, MAP NO. 1747 APN NO.: 206-011-08 PROJECT ADDRESS 152 SEQUOIA A VE. CARLSBAD, CA 92008 DEVELOPER NAME: ERIC AND KIMBERLY C4RR ADDRESS: 152 SEQUOIA A VE, CARLSBAD. CA 92008 PHONE NO.: (760) 434-9270 REFERENCE DRAWINGS CITY OF CARLSBAD WATER SYSTEM IMPROVEMENT PLANS 159-9, SH£ET 18 OF 92 SHEETS CITY OF CARLSB,O SEWf:R IMPROVEMENT PLANS 124--6, SHEET 4 OF 9 SHEETS EARTHWORK QUANTITIES CUT: CY FILL: 10 CY IMPORT: 0 CY LEGEND (53),,------_,.(58) ~ FG=59.1 I II l/////~I ,/////1 PROPERTY BOUNDARY SETBACKS EXISTING CONTOUR PROPOSED CONTOUR FLOWLINE & FLOW DIRECTION (£) WATER MAIN/ LATERAL (E) SEWER LINE PROP. SPOT ELEVATION (E) SPOT ELEVATION (£) EDGE OF PAVEMENT (£) RETAINING/LANDSCAPE WALL (£) BWG TO BE REMOVED PROPOSED BLDG LIMITS (E) CONCRETE DRIVEWAY TO 8£ REMOVED DATED NIA 9. ENVIRONMENTAL APPROVAL DOCUMENTS DATED NIA 10. STORM WATER POLLUT10N PREVENTION PLAN PREPARED BY ENGWEERWG OfStGN GROUP ) OA-1El1-"'f.16~ 1. SW ,'10. S~ 91ts, "S i:tf. WID NO. 9 375 NIA 11. STORM WATER MANAGEMENT PLAN PREPARED BY---...r,,,:.a....... _____ DATED ----SW/v/P NO.·---- 12. CALIFORNIA STORM WATER QUALITY ASSOC/A TION BMP CONSTRUCTION HANDBOOK AND CAL TRANS CONSTRUCT10N SITE BMP MANUAL. LEGEND UEM No, D£SCR[PTIQN REFERENCE (]) 0 @ (]) ® @ 0 ® DRIVEWAY 5" CONCRETE PAVING OVER SUBGRADE COMPACTED TO 90% R.C. CONCRETE PATIO PAVERS, 48' SQ WITH 6" GRASS STRIP BETWEEN PRP. CONG. GRAVITY WALL PRP. GRAVEL PRP. LANDSCAPE AREA 4 • ATRIUM AREA DRAIN 4" DRAIN PIPE PER SORSD C-9, TYPE C NOS OR EQUIV. SDR-35 6" DRAIN PIPE (PRIVATE) SOR-35 ~1ID'i«wD J.".~.'.'I QUANTITTES 1400 SF 3JO SF 300 SF 670 SF 465 SF 3 EA 50 LF 100 LF ® 12" SQ AREA DRAIN NOS OR EQUIV. IIID 5 EA f',:/,. (£) 3/a' WATER METER TO BE UPGRADED TO -:v--O-w-@) 1 EA EXPORT: 30 CY ~G>--~:J---(E) CHAIN LINK/WOODEN FENCE \!Y 1 • WITH FIRE SPRINKLER SYSTEM PER CMWD STD DWG W-JA REMEDIAL: 1000 SF X 4 FT I>/; ;·:·'(;,'·.I (E) AC PAVING ...... 40 SF =16000 CF=600 CY □ (N) DOWNSPOUTS @2 (N) CMU RETAINING WALL PER SDRSD C-3. HEIGHT LESS THEN 3 FT. !ill (E) %" WATER METER BENCH MARK D£SCR/PT1 LOCATION RECORDED ELEVA TIO ON: : : N: POINT NUMB~R 141 (CLSB-141) OF CITY OF CARLSBAD SJRVEY CONTROL, AS SHOWN ON RECORD OF SURVEY 17271. ELEV.=28.618' DATUM: NAVO 88 f/4' NEW STORM DRAIN PIPE OUTLET AND ROCK l!Y LINED SWALE PER DET 1 AND 2/ SHEET 2 SCOPE OF WORK THE SCOPE OF WORK FOR THIS PROJECT WILL CONSIST OF DEMOLITION OF EXISTING SINGLE FAMILY RESIDENCE AND DETACHED GARAGE AND CONSTRUCTION OF NEW SINGLE STORY FAMILY HOUSE WITH DETACHED GARAGE. POST-CONSTRUCTION BMP TABLE STORMWA TER REQUIREMENTS THAT APPLY: EXEMPT FROM HYDROMOD/FICA 710N? ~ STANDARD STORMWA TER REQUIREMENTS PRIORITY PROJECT REQUIREMENTS N/AEI YES (SEE SVIMP FOR DOCUMENTATION) NO TYPE DESCRIPTION O!INERSHIP J.IAINTENANCE SHEET NO. M4ffi'tENANCE AGREEMENT . . FBEQUENCY TOTAL LOT AREA = 5625 SF 11 AS BUIL T11 TOTAL DISTURBED AREA = 5625 SF bTHIS AREA INCLUDES BUT IS NOT LIMITED TO FF-SITE WORK INCLUDING PUBLIC IMPROVEMENTS AND TEMPORARY DISTURBANCE SUCH AS VEHICLE ,)-ERIN RIST AND EQUIPMENT STAGING AREAS, CONSTRUCT10N RCE 65122 EXP, '.U3QL2Ql 2 DATE WORKER FOOT TRAFFIC, SOIL/GRAVEL PILES, UT1LITY mENCHE:S, BACKFILL curs AND SLOPE KEYWA YS) REVIE\vED BY• TOTAL REPLACED IMPERVIOUS AREA = 2675 SF TOTAL PROPOSED IMPER VIGUS AREA -4188 SF INSPECTOR DATE & SHEET 2 REPLACES SHEET 2 APPROVED ON 7/3/2017 I SH~ET I CITY OF CARLSBAD I SH~ETS I REVIS/ED STORM DRAIN OUTLET STRUCTURE; ADD ILl/z."h'< ROCK SWALE -,oc...-ENGINEERING DEPARTMENT MINOR GRADING PLAN FOR: CARR RESIDENCE TITLE SHEET GR2017-0009 - APPROVED: / L 'J) ✓ JASON S. GE _c ERT -• ,,1 ) Vv :;z;; '?A,._, CITY ENGINE]!!: RCE 6Js 2 EXt-lRES 9130118 •ATE OWN BY: ~ PROJECT NO. DRAWING NO. DATE INITIAL DATE INITIAL DATE INITIAL CHKD BY: :,·c ENGINEER OF WORK REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL RVWD BY: ':,[id DEV2017-0034 501-7A ' ' ... 0 ... :. - □ JJ § 2 G'J 2 C s: OJ m JJ □ JJ ~ 2 G'J 2 C s: OJ m JJ □ JJ ~ ~ 2 C s: OJ m JJ □ JJ Cl ~ ~-G') 2 u, Cl 02 -;" C --1 s: )> [J'J m JJ (£) CMU - RETAINING WALL EOG PROJECT No.: 165624-5 DATE: 5-9-17 FG=59.3 GRADING PLAN 0 10 20 Feet GRAPHIC SCALE: 1 "= 1 o' -o" PRE-DEVELOPMENT IMPERVIOUS/ PERVIOUS AREA NAME IMPERVIOUS PROPERTY TOTAL IMPERVIOUS PERVIOUS AREA PERVIOUS AREA AREA SIZE (SF) SIZE (SF) AREA (%) SIZE (SF) (%) HOUSE, GARAGE, 2675 5625 47-5 2951 52,5 DRIVEWAY POST-DEVELOPMENT IMPERVIOUS/ PERVIOUS IMPERVIOUS TOTAL PROPERTY TOTAL IMPERVIOUS PERVIOUS AREA IMPERVIOUS AREA NAME AREA SIZE (SF) SIZE (SF) AREA (%) SIZE (SF) AREA (SF) HOUSE 1907 DETACHED 1150 4188 5625 74_5 1437 GARAGE DRIVEWAY 1132 O+O:J.OCJ 80,00 ~--+-----------------___ -----I---- 78.00 76.00 74,0Q - 72.00 70,00 63.00 6f5-00 61.00 62.00 ""'" 60,00 -- 58,00 - .56.0C - ,-----ROCK EMBEDDED IN CONCRETE AROUND PIPE AT /-SLOPE FACE. ROCKS EMBEDDED APPROX J" MAX ( ROCK SIZE PER DETAIL 1 / THIS SHEET. I 470-C-2000 CONCRETE OR 2500 PSI, AIR ,(E) SLOPE\ PLACED CONCRETE WITH 1 1/2" X 1 1/2" 17 \ GAUGE STUCCO NETTING. CONCRETE 6" THICK MIN . .. \ ""', ~, r"1-s,J-,,~ ~...,\· I , -,<" "'~"'"--_ -I lJ---)5· -(, --,._ ------,-----._ 1 '. ~ I --CUT DRAIN PIPE AT ANGLE OF THE SLOPE PLAN VIEW -../·., __ _ 1 ---1 -...... <la,I N i·· I ~ • _; • • • • ' I · I -, . ·, '-'I . ' . I • I • _4' J --·_,~:::"( (fi- ! l_NEW ROCK SECTION ___ -EXTEND CONCRETE TO THE -' LINED SWALE BOTTOM OF THE SWALE IN PER DET 1 / LOCATION OF SLOPE THIS SHEET PROTECTION AT PIPE OUTLET 1 POST-CONSTRUCTION SITE DESIGN BMPs: MAINTAIN NATURAL DRAINAGE PATHWAYS AND HYDROLOGIC FEATURES CONSERVE NATURAL AREAS, SOILS, AND VEGETATION MINIMIZE IMPERVIOUS AREA MINIMIZE SOIL COMPACTION IMPERVIOUS AREA DISPERSION RUNOFF COLLECTION 0--1 oo.oc; 80,00 - 78.UO 76.0C /4.0C /2.00 70.00 f----~-------t<E-.;.l-,f/,cQ,cc;liSE-IO-= ~ -~~- bb.00 ' -80,00 16.0CJ !d_()i] -t 7?.0() 1-70.00 ; b8.00 : 66.CO --64. 1076 PERVIOUS AREA BE REMOVED '-\ CONCRETE ' t l'v-r \1r DRIVEWAY i -1 I_ I TW= 0 ~ :igg FF=59,0 -Fe= 6 I /1 l_l : C2.C:O (%) I ,--j_-:-~ ~~.~~ . 1 __ • / ' j -Lf(;=597 - -60.00 5C.OO 25,5 "-\-FS=57 9 FL=58.4-' / 1 s4.oo--rs 1.0\ -FS=58.5-1 ': ------------- 52.00---AREA DRAIN PER _ _ _ ) 54.00 50-00 ---+-----6~~~c=t~R~liH~E~RE __ O_T __ 2+-5-_ o-o--~~~fv1~Ni:r~ER iisb co !J+U~JJO SORSD C-9, TYPE "c" G+:J;j? 52.00 -50,00 SECTION 1-1 SCALE: 1 "= 1 O' -0" 1 ,l•C0,00 ----------------~--------r-I+ 00 --------------~------------l-=_:__-80,00 SECTION 2-2 SCALE: 1 "=10'-0" 0 !-3.3.00 70.00 ~-+-----------~---+-~ 70.00 ; 65.00 R, w. ID.UC /6.0() _ ---,') '1(1 i ' __ , 1, ,' ---t--70,00 + 6B.OO ' ~ 6(J.00 I t-G4.00 _t 62.00 ABBREV/A TIONS CONSTRUCT/ON LEGEND -NEW 24" MIN WIDE 6" f HIGH EARTHEN BERM SECTION J SCALE: 1"=10'-0" ~-J~ FF FP FL IE TW HP FS FG TG (E) CL PL (N) F.Y.SB S.Y.SB RY.SB R.W ( AT THE BASE OF THE : (E) SLOPE. SEE PLAN/ ,,--APPROX 6"¢-8"¢ CLASS 11 /-AT TRANSITION FLATTEN ROCK I BACKING ROCK TYPE / SWALE TO FLOW BACK TO \ THIS SHEET OVER GEOTEXTILE LINING ( STREET PAVEMENT, WEST END \ r·-(E) SLOPE / OF PROPERTY 1 --..----..._ ~-\, TO REMAIN '1, I je;,!~1-t '--\ --18_"_:->cl~E __ ::;-r~-=/:-_JtFfMENT -' I~-------e'-c ~-±" ✓.->--:, I -_ "li-,1:i-, .,.., .6..-~. ,_,--11=-4" • (10.2CM, -I ;;---\\ 3" -0.2C ) ANCHOR 7!'.J" -t;, _5cl<I) 16c4t,1 , ./':IQI£S PLACE -3 ANCHORS PER SQUARE YARD OF GEOTEXTILE MATERIAL 2. INSTALL GEOTEX WOVEN ffi MONOFILAMENT GEOTEXTILE (NO. 117 FT. OR EQUAL) ROCK LINED SWALE (j) NOT TO SCALE , . . -- FINISHED FLOOR ELEVATION FINISHED PAO ELEVATION FLOW LINE CD 5" DRIVEWAY CONCRUE PAVING OVER SUBGRADE COMPACTED TO 90% R.C, r,,\ 48" SQ CONCRETE PAVERS WITH 6" ~ LANDSCAPE STRIP BETWEEN INVERT ELEVATION TOP OF WALL HIGH POINT FINISHED SURFACE FINISHED GRADE TOP OF GRATE EXISTING CENTERLINE PROPERTY LINE NEW FRONT YARD SETBACK SIDE YARD SETBACK REAR YARD SETBACK RIGHT-OF-WAY 1 (3"\ PROPOSED CONG. GRAVITY WALL PER V SDRSD C-9, TYPE C G) PROPOSED GRAVEL AREA @ PROPOSED LANDSCAPE AREA @ 4" ATRIUM AREA DRAIN (D 4" SDR-35 DRAIN PIPE @ 6" SDR-35 DRAIN PIPE (PRIVATE) r;,, 12" SQ. AREA DRAIN, NOS \.V BOX OR [QUIV @ (II) CONCREFE CURB OUTLET __ '-"--" l"Ell 30R30 B-25 f1i\ (E) B WATER METER TO BE \!Y UPGRADED TO 1 " FOR DOMESTIC AND FIRE SPRINKLER SYSTEM A PROPOSED CMU RETAINING WALL PER '!31 SORSD C-J, HEIGHT LESS THAN J' 6:;;;::'.~~~~~~~~~~~~~-) ITI) RIP RAP 5'/ER61' 0155/F'ATOR PER SDRSD ) "=!, tl-40, 1)1'[ 1, ROCK CLAS$ NO. 1 BACKIAJG / ri:i\ NEW STORM DRAIN PIPE OUTLET AND ~-__,, ~ ROCK LINED SWALE PER DET 1 AND 2/ THIS SHEET _,._,_ ~~__...,...,. 11 AS BUIL T11 ERIN RIST DATE RCE 65122 EXP, 9/30/2019 REVIE\./ED BY: INSPECTOR DATE §D-:_~ isr5_=-~ ISD-4I [SQ~~ is5:=B lsD-71 LANDSCAPING WITH NATIVE OR DROUGHT TOLERANT SPECIES & THIS SHEET REPLACES SHEET 2 APPROVED ON 7/J/2017 REVISED STORM DRAIN OUTLET STRUCTURE; ADD ROCK SWALE '!/2<-/1r --;-r,_C- I SH~ET I CITY OF CARLSBAD I SH~ETS I ENGINEERING DEPARTMENT POST-CONSTRUCTION SOURCE CONTROL BMPs: ~c_=--~ [g;__::] [sc:-:] [gc_-:_~ ~ PREVENTION OF ILLICIT DISCHARGES INTO THE MS4 STORM DRAIN STENCILING AND SIGNAGE PROTECT OUTDOOR MATERIALS STORAGE AREAS PROTECT TRASH STORAGE AREAS ADDNL BMPS BASED ON POTENTIAL SOURCES OF RUNOFF POLLUTANTS: ON-SITE STORM DRAIN INLETS -- ---- ' 1 - DATE INITIAL ENGINEER OF WORK ---- -----·" ------- - ---. ---- __ ,. --------- ------------- - --- --------------··- -····· ---- - ----- DATE INITIAL REVISION DESCRIPTION OTHER APPROVAL MINOR GRADING PLAN FOR: CARR RESIDENCE GRADING PLAN GR2017-0009 APPROVED://. ii JASON S, GEL rlERT ' / ,ill, 'I z£ l/J 1q CITY ENGINczER RCE 63912 EXPIRES 9/30/18 [ ATE DWN BY: 8V PROJECT NO. DRAWING NO, DATE INITIAL CHKD BY: CITY APPROVAL RVWD BY: DEV2O17-OO34 5O1-7A I . C, :e N C) 0 UI ... 0 ,c,. ... ' -.i ~ □ JJ ~ 2 Gl 2 C !l: CIJ m JJ □ I 2 Gl 2 C !l: CIJ m JJ □ JJ ~ 2 Gl 2 C s CIJ m JJ □ JJ ~ 2 Gl 2 C s CIJ m JJ TIER 2 CITY STORM WATER POLLUTION PREVENTION PLAN (TIER 2 SWPPP) STORM WATER PQt t UVON PRE,VOO/ON NQTfS GENERAL SUE MANAGEMENT REOUIREMENTS THE FOLLOWING GENEJIAL SITE: MANAGEMENT REQUJREMEN1S SHALL BE ADHERED TD THROUGHOUT THE DURATION OF THE CONSTRUCT/ON WORK (YEAR ROUND): 1. IN CASE EMERGENCY WORK IS REQUIRED, CONTACT ERIC CARR AT CELL PHONE #: (760) 434-9270. 2. D£V/CES SHOWN ON C/1Y APPROVED SHALL NOT BE MOVED OR MODIFIED WITHOUT THE APPROVAL OF THE ENGINEERING INSPECTOR. J. THE CONTRACTOR SHALL RESTORE ALL EROSION CONTROL DE:VICES TO WORKING ORDER TO THE SAT/SFACTTON OF THE CITY ENGINEER AFT£R E:ACH RUN-OFF PRODUCING RAINFALL 4. THE CONTRACTOR SHALL INSTALL ADDITIONAL EROSION CONTROL ME:ASURES AS MAY BE REQUIRED BY THE C/1Y ENGINEER DUE TO UNCOMPLETED GRADING OPERATIONS OR UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE. 5. THE CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PRE:VENT PUBLIC TRESPASS ONTO ARl::AS WHERE IMPOUNDED WATERS CRE:A1f A HAZARDOUS CONDITION. 6, GRADED ARE:AS AROUND THE PROJECT PER/MErrR MUST DRAIN AWAY FROM THE FACE OF THE SLOPE AT THE CONCLUSION OF l::ACH WORKING DAY. 7. ALL REMOVABLE DETECTIVE D£VICES SHALL BE IN PLACE AT THE END OF l::ACH WORKING DAY WHEN THE FIVE (5) DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PERCENT (40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER l::ACH RAINFALL. B. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM AGGREGA1f. 9. ALL EXPOSED DISTURBED ARfAS MUST HAVE EROSION PR01FCTION BMPs PROPERLY JNSTALL£D, THIS INCLUDES ALL BUILDING PADS, UNFINISHED ROADS, AND SLOP£S, 10. ADEQUA1f PERIMErrR PROTECTION BMPs MUST BE INSTALLED AND MAINTAINED AND WILL BE UPGRADED, IF NECESSARY, TO PROVIDE sumCIENT PR01fCTION FROM RUNOFF DURING RAIN EVENTS. 11. ADEQUA1f SEDIMENT CONTROL BMPs MUST BE INSTALLED AND MAINTAINED. 12. ADEQUATE BMPs TO CONTROL OFFS/TE SEDIMENT TRACKING MUST BE INSTALLED AND MAINTAINED. 13. A MINIMUM OF 125% OF THE MATERIAL NEEDED TO INSTALL STANDBY BMPs TO PROTECT THE EXPOSED ARl::AS FROM EROSION AND PREVENT SEDIMENT DISCHARGES, MUST BE STORED ONSITE. AREAS ALRE:ADY PR01fCTED FROM EROSION USING PHYSICAL STAB/LIZA TION OR ESTABLISHED VEGETATION STABILIZATION BMPs ARE NOT CONSIDERED TO BE •EXPOSED" FOR PURPOSES OF THIS REQUIREMENT. 14. THE OWNER/DEVELOPER/CONTRACTOR Musr FOLLOW 'WE:ATHER TRIGGERED" ACTION PLAN AND BE ABLE TO DEPLOY STANDBY BMPs TO PROTECT THE EXPOSED PORTIONS OF THE SITE WITHIN 48 HOURS OF PREDICTED STORM EVENT (A PREDICTED STORM EVENT IS DEFINED AS A 40% CHANCE OF RAIN WITHIN A 5-DAY NATIONAL WfATHER SERVICE FORECAST), ON REQUEST, THE OWNER/DEVELOPER/CONTRACTOR MUST PROVIDE PROOF OF THIS CAPABILITY. 15. DEPLOYMENT OF PHYSICAL OR VEGETATION EROSION CONTROL BMPs MUST COMMENCE AS SOON AS SLOPES ARE COMPIEED. THE OWNER/DEVELOPER/CONTRACTOR MAY NOT RELY ON THE ABIL/1Y TO DEPLOY STANDBY BMP MATERIALS TO PREVENT EROSION OF SLOPfS THAT HAVE BEEN COMPLETED. 16. THE ARl::A THAT CAN BE CLE:ARED, GRADED, AND LEFT EXPOSED AT ONE TIME IS LIMITED TO THE AMOUNT OF ACRl::AGE THAT THE CONTRACTOR CAN ADEQUATELY PROTECT PRIOR TO A PREDICTED RAIN E:VENT. FOR LARGER SITES, GRADING SHOULD BE· PHASED. /T MAY BE NECESSARY TO DEPLOY EROSION AND SEDIMENT CONTROL BMPs IN AREAS THAT ARE NOT COMPLETED, BUT ARE NOT ACTTVELY BEING WORKED BEFORE AOOITTONAL GRADING IS ALLOWED TO PROCEED, AT THE DISCRETION OF THE CITY INSPECTOR. 17. ALL DISTURBED AREAS THAT ARE NOT COMPLErrD AND/OR NOT BEING ACTIVELY GRADED MUST BE FULLY PROTECTED FROM EROSION IF LEFT FOR 14 OR MORE DAYS. THE ABILITY TO INSTALL BMP MATERIALS IN A PROMPT MANNER IS t!QLSUFFICIENT. BMPs NEED TO BE INSTALLED IN THESE ARl::AS. 18. BMPs MUST BE STOCKPILED AT VARIOUS LOCATION THROUGHOUT THE PROJECT SITE: THROUGHOUT THE YEAR. WHENE:VER THERE 15 A 40% CHANCE OR GRE:ATER OF A RAIN WITHIN A THREE (J) DAY FORECAST, THE INSPECTOR WILL VERIFY THAT BMPs ARE ADEQUATELY STOCKPILED. BMPs MUST BE STOCKPILED ANO RE:ADY FOR DEPLOYMENT WHEN THERE IS 50% CHANCE OF RAIN WITHIN 48 HOUR FORECAST. FAILURE TO COMPLY WITH THIS REQUIREMENT COULD RESULT IN THE ISSUANCE OF A STOP WORK NOTICE' OR OTHER ENFORCEMENT ACTION. 19. ALL TREATMENT AND EROSION CONTROL BMPs MUST BE INSPECTED WEEKLY AND PRIOR TO A FORECASrrO RAIN EVENT OF GREATER THAN 50%, AND AFTER A RAIN EVENT. IN ADDITION, TRE:A TM ENT CONTROL BMPs MUST BE SERVICED AS NEEDED THROUGHOUT THE YEAR. 20. IF SELECTED BMP FAILS DURING A RAIN EVENT, /T MUST BE REPAIRED OR IMPROVED OR REPLACED WITH AN ACCEPTABLE ALTERNA1f AS SOON AS IT IS SAFE TO 00 SO. THE FAILURE OF A BMP INDICATfS IT WAS NOT ADEQUA1f FOR THE CIRCUMSTANCES IN WHICH /T WAS USED. REPAIRS ANO REPLACEMENT MUST THEREFORE PUT A MORE ROBUST BMP MEASURE IN PLACE. 21. ALL CONSTRUCTION EMPLOYEES MUST BE TRAINED ON THE IMPORTANCE OF STORM WATER POLLUTION PREVENTION ANO BMP MAINTENANCE. WEA1HE'R TRIGGERED ACTION PlAN THE DEVELOPER SHALL DEPLOY STANDBY BEST MANAGEMENT PRACTTCE ME:ASURES TO COMPLETELY PROTECT THE EXPOSED PORTIONS OF THE SITE WITHIN 48 HOURS OF A PREDICTED STORM E:VENT (A PREDICTED STORM E:VENT IS DEFINED AS A FORECASTED, 40% CHANCE OF RAIN BY THE NATIONAL WEATHER SERVICE), IN ADDITION TO BMPs IMPLEMENTED YEAR-ROUND INCLUDING PERIMETER CONTROL, TRACKING, NON-STORM WATER CONTROL, WASTE MANAGEMENT, AND MATERIALS POLLUTION CONTROL. THE NATIONAL WE:ATHER SERVICE FORECAST SHALL BE MONITORED AND USED BY THE DEVELOPER AN A DAILY BASIS, IF PRECIPITATION IS PREDIC1fD (40% CHANCE OF RAIN), THEN THE NECfSSARY WATER POLLUTION CONTROL PRACTICES SHALL BE DEPLOYED WITHIN 48 HOURS ANO PRIOR TO THE ONSET OF THE PRECIP/TAT/ON. THE DEPLOYMENT OF THE BMPs SHALL INCLUDE BUT NOT BE LIMITE:0 TO GRAVEL BAGS ANO SILT FENCES. A MINIMUM OF 125% OF THE MATERIAL NEEDED TO INSTALL STANDBY BEST MANAGEMENT PRACT/CfS Ml::ASURES TO PROTECT THE EXPOSED ARl::AS FROM EROSION ANO PREVENT SEDIMENT DISCHARGES MUST BE STORED ON-S/TE. AREAS THAT HAVE ALRl::ADY BEEN PROTEC1fD FROM EROSION USING PHYSICAL STABILIZATION OR ESTABLISHED VEGETATION STABILIZATION BMPs AS DErrRMINED BY THE CITY OF CARLSBAD ARE NOT CONSIDERED TO BE 'EXPOSED• FOR THE PURPOSES OF 'Wl::ATHER TRIGGERED ACTION PLAN". AN ADEQUATE SOURCE OF EQUIPMENT AND WORKERS SHALL BE AVAILABLE FOR DEPLOYMENT OF 'WE:ATHER TRIGGERED BMPs'. EROSION CONTROL HYDRQSEEDING, PlANTJNG AND IRRJGAJON 1. ALL PERMANENT ANO TEMPORARY EROSION CONTROL PLANTING AND IRRIGATION SHALL BE INSTALLED AND MAINTAINED AS REQUIRED IN SECTTON 212 OF THE STANDARD SPECIFICATIONS AND THE FOLLOWING: A HYDROSEEDING SHALL BE APPLIED TO: 1. ALL SLOPES THAT ARE GRADED 6: 1 (HOR/ZONrAL TO VERTICAL) OR STEEPER THEN THEY ARE: a. THREE FEET OR MORE IN HEIGHT AND ADJ/CENT TO A PUBLIC WALL OR STREET. b. ALL SLOPES 4 FEET OR MORE IN HEIGHT. 2. AREAS GRADED RATTER THAN 6: 1 WHEN ANY OF Tl£ FOLLOWING CONDITIONS EXIST: a. NOT.SCHEDULED FOR IMPROVEMENTS (CONSTRUCT/ON OR GENERAL LANDSCAPING) WITHIN 60 DAYS OF ROUGH ;RAO/NG. b. IDENTIFIED BY THE PARKS AND RECRl::AT/ON DIRECTOR AS HIGHLY VISIBLE TO THE PUBLIC. c. HAVE ANY SPECIAL CONDITION IDENTIFIED 81 THE C/1Y ENGINEER THAT WARRANTS IMMEDIATE TREATMENT. .8. HYDROSEEDEO AREAS SHALL 8£ IRRIGATED IN ACJOROANCE WITH THE FOLLOWING CRITERIA: 1. ALL SLOPED THAT ARE GRADED 6:1 OR STEEPER ANO THAT ARE: a. THREE TO EIGHT FEET IN HEIGHT SHALL Bt IRRIGATED BY HAND • WA 1fRING FROM QUICK COUPLERS/ HOSE /'JBS OR A CONVENTIONAL , ' SYSTEM OF LOW PRE:CIPITAT/ON SPRINKLER .'ffADS PROVIDING 100% COVERAGE. b. GREATER THAN 8 FEET IN HEIGHT SHALL Bf WATERED BY A CONVENTIONAL SYSTEM OF LOW PRECIP/TAllON SPRINKLER HEADS PROVIDING 100% COVERAGE. 2. ARE:AS SLOPED LESS THAN 6:1 SHALL BE /Fil/GATED AS APPROVED BY THE CITY ENGINEER, PRIOR TO HYDROSEEOING. Jf/E DEVELOPER SHALL SUBM/T PROPOSED SCHEME TO PROVIDE IRRIGATION TD THE C/1Y ENGINEER. THE PROPOSAL SHALL BE SPECIFIC REGARDING iHE NUMBERS, TYPES, AND COSTS OF THE ELEMENTS OF THE PROPOSED SYSTEM. 3. /RR/GA TION SHALL MAINTAIN THE MOISTURE LiVEL OF THE SOIL AT THE OPTIMUM LEVEL FOR THE GROWN OF THE hYDROSEEDED GROWTH. .C HYDROSEEDING MIX SHALL CONSIST OF ALL OF THE FOLLOWING: 1. SEED MIX SHALL CONSIST OF NO LfSS THAI!: a. 20 lbs. PER ACRE OF ROSE CLOVER b. 20 lbs. PER ACRE OF' ZORRO FESCUE o. J lbs. PER ACRE OF E SCHOOL CIA CALIFORNICA d. 4 lbs, PER ACRE OF ACH/LLE:A M/LLEFOLIA e. 3 lbs. PER ACRE OF ALYSSUM (CARPET CF SNOW) f. ½ lb. PER ACRE OF 0/MORPHOLECA g. ITEMS c, d, e AND f OF THIS SUBSECT/Dll MAY BE OMITTED ON LOCATIONS WHERE THE ARE:A BEING HYDROSEEDE IS NOT VISIBLE FROM EITHER A PUBLIC STREET OR RESIDENTIAL STRUCTURES. h. ITEM a OF THIS SUBSECTION MUST BE INOCULATED WITH A N/TROGEN FIXING BACTERIA AND APPLIED DR'( £/TH£'? BY DRILLING OR BROADCAS/NG BEFORE HYOROSEEDING. i. ALL SEED MA1fRIALS SHALL BE TRANSPORTED TO THE JOBS/TE IN UNOPENED CONTAINl::RS WITH THE CALIFO?NIA OEPAITTMENT OF FOOD AND AGR/CULTIJRE: CERTIFICATION TAG ATTACHED TO, OR PRINTED ON SNO CONTAINERS. j. NON-PHYTO-TOXIC WETTING AGENTS MAY BE ADDED TO THE HYDROSEED SLURRY AT THE DISCRETION OF THE CONTRACTOR. 2. TYPE 1 MULCH APPLIED AT THE RATE OF NO LESS THAN 2000 lbs. PER ACRE. TYPE 6 MULCH (STRAW) MAY BE SUB:TITUTED, ALL OR PART, FOR HYDRAULICALLY APPLIED FIBER MATERIAL. WHfN STRAW IS USED, /T MUST BE ANCHORED TO THE SLOPE BY MECHANICAL Y PUNCHING NO LESS THAN 50% OF THE STRAW INTO THE SOJL. J. FERTILIZER CONSISTING OF AMMONIUM PHOSPHATE SULFATE, 16-20-0, WITH 15% SULPHUR APPLIED AT THE RATE OF 500 lbs. PER ACRE. J2 ARE:AS TO BE HYDROSEEOED SHALL BE PREPAREi> PRIOR TO HYDROSEEDING BY: 1. ROUGHENING TH£ SURFACE TO BE PLANTED 8Y ANY OR A COMBINATION OF; a. TRACK WALKING SLOPfS STEEPER THAN 61 b. HARROWING ARl::AS 6:1 OR FLATTER THAT ARE SUFFICIENTLY FRIABLE. c. RIPPING AREAS THAT WILL NOT BREAK UP USING /'TEMS a OR b ABOVE. 2. CONDITIONING THE SOILS SO THAT IT IS SU/TJBLE FOR PLANTING BY: a. ADJUSTING THE SURFACE SOIL MOISTURE ro PROVIDE A DAMP BUT NOT SATURATED SEED BED, b. THE ADDITION OF SOIL AMENDMENTS, PH IDJUSTMENT, Ll::ACHING COVERING SALINE SOILS TO PROVIDED VIAELE CONOmONS FOR GROwrH. I;_ HYDROSEEDED ARE:AS SHALL BE MAINTAINED TO PROVIDE A VIGOROUS GROWTH UNTIL THE PROJECT IS PERMANENTLY LANDSCAPED OR, FOR AREAS WHERE HYOROSEEDING IS THE PERMANENT LANDSCAPING, UNTIL THE PROJECT IS COMPLErrD AND ALL BONDS RELEASED. 2. ALL SLOPES SHALL HAVE IRRIGATION INSTALLE:J AND BE STABILIZED, PLANTED ANO/OR HYOROSEEDED WITHIN TEN (10) DAYS OF THE TIME WHEN fAf,;1:1 SLOPE IS BROUGHT TO GRADE AS SHOWN ON THE APPROVED GRADING PLANS. 3. SHOUW GERMINATION OF HYDROSEEDED SLOFf:S FAIL TO PROVIDE EffiCIENT COVERAGE OF GRADED SLOPfS (90% COVERAC£) PRIOR TO OCTOBER 1, THE SLOPES SHALL BE STABILIZED BY AN APPROPKIA1f EROSION CONTROL MAmNG MATERIAL APPROVED F!Y THE PUBLIC WORKS INSPECTOR. 4. LANDSCAPING SHALL BE ACCOMPLISHED ON ALL SLOPES AND PADS AS REQUIRED BY THE C/1Y OF CARLSBAD LANDS~APE MANUAL, THE LANDSCAPING PLANS FOR THIS PROJECT, ORi,W/NG NO. N/A , AND/OR AS DIRECTED BY THE C/1Y ENGINEER OR PLANNIWG DIRECTOR. 5. TH£ OWNER/APPLICANT SHALL ENSURE THAT .ILL CONTRACTORS SHALL COORDINA1f THE WORK OF THIS CONSTRUCTON SWPPP SHOWN ON ANY GRADING PLANS, LANDSCAPE AND IFWGATION PLANS AND IMPROVEMENT PLANS AS REQUIRED FOR THIS PROJECT WORK. BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE Erosion Control Sediment Control BMPs Tracking BMPs Control BMPs .§ ,§ .., --C: ./!J C: § Cl Cl :2 ~ ~ j -.E t .., 8l "' ... .!!! 15 .e 0 .s -~ .s "' "al "' 6 o ·i ~ § 8l .§ Best Management Practice* Q) "" ,S "' ~ C: "" 33Ji Ji .E; <...) l!! 1 ii ,S ,!l "' § (8MP) Description ➔ :8 ~ 8l C, " " l ~ "' ec "' -~ Q,) ~ -& ]¾2_ al s ~-~ I :Sl <,) fii C, (/) .s; g, Q~ C, "' .c, <:: -§ 0 ~ eM ·-8l .~ 3: e .., 'f§ ,S " ·a ~ ~ :u l Q) ::, 'ls """ "" .., .,-& o· ~a -g 0 cl:~ i' 0 0 -Q) & l!! " C: .s e c'.ll i 01:! l, a ~ 05 l.il C, vl ~ <'l 01~ er, c,,: er, .s tn& CASQA Designation ➔ I' ... " I<) 0, -"' ,,, ... "' " I<) "' "' ---<o --I I I I 6 6 J., J., ~ J., ~ ~ J., ~ g, g, f:i3 f:i3 f:i3 f:i3 f:i3 Construction Activity Lil CJ (,ij (,ij (,ij (,ij X Gradina/So/1 Disturbance ,,,x... X X ..,,, >< ...,.,.. ~ IX Trench/no /Excavation Stockp/1/nQ Dri/1/nn/Borina Concrete/Asohalt Sawcuttina X Concrete Flotwork Pav/no Condult/Pioe Installation Stucco/Mortar Work Waste Oisoosal Staainn/Lav Down Area Eauloment Maintenance and Fuel/no Hazardous Substance Use /Storaoe Oewaterina Site Access Across Dirt Other flist ): Instructions; lon•Storm Water Waste Management and Materials Mmagement BMPs Pollution Control BMPs C: -,9 fii --.., fii "' >:l E .., C: ~ l § ~ § ~ ,g. .s .la 1 ::, i g, ~ lif C: lg <.'!; j ~ ~ -;,;_ -"' .., "' ~ .,, C: ~~ " fii J e <:: C, ~ e a 0 "" ifil .g ~ -" " .!!! -" "" ct:o o,:+:. " ,<:: .g 1:1') .g ~ "' " "" :u"' i:: ~ -g cJC: " e _-b ~g " 0 -8 ·s ·-0 2 " -.,: " ~o 0 ""<: N 5 ~ d:: ii: c5 & 0 -0 br8 -" ~o ::e er, ::e V, '5l ::e i::e ,,, " I<) -"' ,,, ... "' <o -i i I I I I J, J, J, ~ i i i i ::,: ::,: :a: _,><... _,><... >< '< >< X >< ~ >< ' -fii 2 .Q E -" "' ~"" i§ er, 0 -:,... § ~~ c::e l!! "" " " " 0 ~-C: <:: C: "' 8~ ~~ I<) 0, I I i i >< >< >< OJECT SITE PACIFIC OCfAN SHEET INDEX /. TITLE SHEET ~ ,._.,.. ~ AQUA HEOIONDA LAGOON VICINITY MAP NOT TO SCALE 2. EROSION CONTROL PLAN LEGAL DESCRIPTION/ APN NO. LOT B IN BLOCK "H" OF PALISADES, IN THE CITY OF CARLSBAD, COUNTY OF SAN DIEGO, MAP NO. 1747 1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction. APN NO.: 206-011-0B 2. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwater Quality Association (CASQA) designation number. Choose one or more BMPs you intend to use during construction from the list. Check the box where the chosen activity row Intersects with the BMP column. SITE ADDRESS 152 SEQUOIA A VE. CARLSBAD, CA 92008 3. Refer to the CASQA construction handbook for information and detalls of the chosen BMPs and how to apply them to the project. LEGEND D£SCRIPTION SYMBOL -~ RIEi RAP OJSS/f/AT0¾,;;:::,;:::==..€1:ffl;ifi ==r==pER~SORSITF'fO,~TT'PE 2 IEC-2I ISE-1I /SE-6I ISE-7I PRESERVATION OF EXISTING VEGETATION SILT FENCE (SC-1) PER DET £2/SHT 4 GRAVEL BAGS PER DET E1/SHT 4 STREET SWEEPING AND VACUMING -0----0- I SE_ 1 0 I STORM DRAIN INLET · · PROTECTION !TR-11 IWM-2 IWM-~ IWM-4! IWM-Ej IWM-§ IwM-a IWM-§j STABILIZED CONSTRUCT/ON ENTRANCE PER OET E3/SHT 4 MATERIAL USE STOCKPILE MANAGEMENT SPILL PREVENTION AND CONTROL SOLID WASTE MANAGEMENT HAZARDOUS WASTE MANAGEMENT CONCRETE WAS1E MANAGEMENT SANITARY WASTE MANAGEMENT CROSS-REF CASQA CONSTRUCT/ON BoST MANAGEMENT PRACTICES OWNER'S CERTIFICATE \'£ UNDERSTAND AND ACKNO'id.£DGE THAT \'£ MUST: (1) IMPLEMENT BEST MANAGEMENT PRACTICES (BMPs) DURING CONSTRUCT/ON ACTIVITIES TO THE MAXIMUM EXTENT PRACTICABLE TO AVOID THE MOB/LIZA T/ON OF POLLUTANTS SUCH AS SEDIMENT ANO TO AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCT/ON RELATED POLLUTAN1S; AND (2) ADHERE TO, ANO AT ALL TIMES, COMPLY 'MTH THIS CITY APPROVED TIER 2 CONSTRUCT/ON SWPPP THROUGHOUT THE DURA T/ON OF THE CONSTRUCT/ON ACTIVITIES UNTIL THE CONSTRUCT/ON WORK IS COMPLETE AND SIGNED OFF BY THE CITY OF CALRLSBAD. ,E!!f_9 CARR ~Judl/ fdA,( KIMBERLY 9}RR 7DArr' NAME OF PREPAR':R: ENGINEERING DESIGN GROUP t'i\OF ESS lo~ '\.{.) ".fl AREA OF DISTURBANCE AREA OF DISTIJRBANC£ = -~5=6=25~SF_ (THIS AREA INCLUDES BUT IS NOT LIMITE:D TO OFF-SIT£ WORK INCLUDING PUBLIC IMPROVEMENTS AND TE:MPORARY DIS71JRBANC£ SUCH AS VEHICLE AND EQUIPMENT STAGING AREAS, CONSTRUCT/ON WORKER FOOT TRAFFIC, SOIL/GRA \/EL PILES, UTILITY TRENCHES, BACKFILL CUTS AND SLOPE K£YWA YS) CONSTRUCTION THREAT: CONSTRUCT/ON THREAT TO STORM WATER QUALITY (CHECK BOX): □ HIGH Ill MEDIUM OWNER/ APPLICANT NAM£: £RIC AND KIMBERLY CARR ADDRESS: 152 SEQUOIA A VE'. CARLSBAD, CA 92008 TE:LEPHON£ NO.: (760) 434-9270 EMERGENCY CONTACT NAME: ERIC CARR ADDRESS: 152 SEQUOIA A VE. CARLSBAD, GA 92008 T£L£PHON£ NO.: (760) 434-9270 I SH~ET I CITY OF CARLSBAD ENGINEERING DEPARTMENT · I SH~TS I CITY STORM WATER POLLUTION PREVENTION PLAN (S'IYPPP) QUALIFICAllON OF PREPARER: REGISTERED CIVIL ENGINEER .,-. ~\'ti, E , f? 1 e+. ADDRESS; 212 ~ONllEL ROAD ~ ~;,. <i'..,. CARR RESIDENCE ;;-~ SAN MARCOS, CA 92069 " "' EROSION CONTROL PLAN "' "' No, 65122 E:xp, 09/30/0017 GR2017-0009 /J • ' ii )j, APPROVED: (I I'/ _,,,-;tf JASON S.f/!J~e PHONE NO. (760: BJS-7302 ,,p)' .,_":' ¼"~ EXPIRES 9/30/18 ':/, DATE . ~,.,r a1v1\. 0-+,'+-. CITY ENGINE ;,t< RC£ 63912 I OF CAt.\1 . ·~ ) OWN BY: w, PROJECT NO • DRAWING NO. /' 65122 09/30/17 (,r2,o-L7 . CHKD BY: _ye_ 'V 'ERIN 1ST R.C.E. NO. UC. EXP. DATE DATE RVWD BY: ~ f.f, DEV2017-0034 501-7A I ' w 0 ... .s:,. Cl ~ G') (JI 0 ... ' ..... )> □ JJ ~ 2 GJ 2 C ~ ca m JJ □ JJ ~ 2 G'l 2 C ~ ca m JJ □ JJ § 2 G'l 2 C ~ ca m JJ □ JJ ~ 2 G'l 2 C: ~ ca m JJ (E) POWER POLE TO REMAIN EROSION CONTROL PLAN 20 Feet GRAPHIC SCALE: 1'=10'-0' Nor£: SECTION rut::l 1. SIT POSTS ANO EXCAVATE A 4 x 4 IN (10 BY 10 CM) TRENCH UPSLOPE FROM AND ALONG THE LINE OF POSTS. --------...---:'1/ /..,,--/ NOTES 1. J/4' ROCK IN BURLAP TYPE BAGS. 2. BURY RRST BAG ONE HALF BAG DEPTH. J. PLACE BAGS TWO HIGH. ~~-11,-11'1 ~ ...-flTr _ 4 x 4 TRENCH (10 CM) 2. ATTACH THE FILTER FABRIC ANO EXTEND IT INTO THE TRENCH J. BACKRLL AND COMPACT THE EXCAVATED SOIL. .,..=N~':'--'/ ~::::;.:o T_scA...:..f-=t,.,_N:..:::C=E'---@ • CQ 1-112· CRUSHED ROCK !REFERENCE: CASQA* TR-11 cm * CALIFORNIA STORMWATER QUAL/1Y ASSOCIATION -CALIFORNIA STORMWATER BMP HANDBOOK; CONSTRUCTION EXISTING GROUND PROFILE" .rut/ PROVIDE APPROPRIATE TRANSIT/ON BTWN STABILIZED CONSTRUCTION ENTRANCE AND PUBLIC RIGHT OF WAY SE€ 5-neer '2 ftJ-te. Revl-S'(5D errof!H PRAfµ oll'TU?r .srll.l(c;fl.-l(?E /rf-).D N~J.J f?ock .S/../Af-E. STABILIZED CONSTR. ENTRANCE NOT TO SCALE 1076 r--------------------'lsi-Tffil CITY OF CARLSBAD 'SHEETS! NAME OF PREPARER: _EN<,INEERING DESIGN GROUP ~ ENGINEERING DEPARTMENT 4 ~i<.ifESS:Jo,v. STORM WA QUAUFICA110N OF PREPARER: REGIS"JERED CIVIL ENGINEER ;.• E <, TER POLLUTION PREVENTION PLAN (S\lf>PP) ,,,.;."-'-,c.,\~ • 1?1~ <',;, ADDRESS: 212 MJN11EL ROAD ,, '<? u;, •';, CARR RESIDENCE SAN ~ARCOS, CA 92069 $ No, 65122 'a EROSION CONTROL PLAN !:xp, 09;3012017 GR2017-0009 -I< * PHONE NO. (760) 839-7302 APPROVED: JASON S. GELDERT CITY ENGINEER RCE 63912 EXPIRES 9130118 DATE 65122 09/30/17 R.C.E, NO. UC. EXP. DA 1E DA"JE g~~D BJ~: u ]c_ PROJECT NO. DRAWING NO. RVWD BY: ( fll.. DEV2017 0034 501 7 A CJ JJ i . 2 G1 2 C ~ [!l m JJ ' CJ JJ ~ • 2 G1 2 C ~ [!l m JJ CJ JJ Cl~ ::e -. ~ Cl 2 0 UI G1 .... C 2 .I>, ... C ' "" ~ J:,, [!l m JJ