Loading...
HomeMy WebLinkAbout1630 FARADAY AVE; ; FPC2021-0102; PermitPERMIT REPORT Fire Permit Print Date: 01/12/2022 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: 1630 FARADAY AVE, CARLSBAD, CA 92008-7313 FIRE-Construction Commercial Work Class: 2121302200 Track#: $1,224,143.20 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: ELAGO -SPRINKLER Tl (86 HEADS) FEE FIRE NFPA 13 or 13R System 7 -100 heads Fire Sprinklers Total Fees: $553.00 Total Payments To Date: $553.00 Fire Department C cityof Carlsbad Permit No: FPC2021-0102 Status: Closed -Finaled Applied: 06/09/2021 Issued: 07/08/2021 Finaled Close Out: 01/12/2022 Inspector: Final Inspection: Balance Due: AMOUNT $553.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov tqca. Worldwide I Contacts www.tyco-fire.com Series TY-B, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers described in this data sheet are standard response, standard cov- erage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, com- mercial occupancies such as banks, hotels, shopping malls, factories, refin- eries, and chemical plants. The recessed version of the Series TY-B Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-B Sprinklers are described in Tech- nical Data Sheet TFP352. Sprinkler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 IIJ-iAA◄ The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Numbers (SINsJ TY315 .... Upright 5.6K, 1/2 in. NPT .... Pendent 5.6K, 1/2 in. NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* • The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato• ries, Inc. (UL). Discharge Coefficient K = 5.6 GPM/psi¼ (80,6 LPM/bar¼) Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................ Bronze Button ...................... Brass/Copper Sealing Assembly ... Stainless Steel w/TEFLON Bulb ............................... Glass Compression Screw ................. Bronze Deflector .................•........ Bronze AUGUST 2018 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Loss Preven- tion Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. TFP152 TFP152 Page 2 of4 Components: 1 -Frame 2 -Button 4 -Bulb 5 -Compression Screw * Temperature rating is indicated on Deflector. ** Pipe thread connections per ISO 7-1 can be provided on special request. 3 -Sealing Assembly 6 -Deflector* DEFLECTOR* ESCUTCHEON PLATE SEATING SURFACE 1/2' 7/16" (11,1 mm) NPT** NOMINAL MAKE-IN STYLE 15 or 20 RECESSED ESCUTCHEON 7/16' (11,1 mm) NOMINAL MAKE-IN 2" (50,8mm) j CROSS SECTION 1/2' NPT** UPRIGHT I 2· (50,8 mm) I f 1-3/8" I J (34,9mm) WRENCH FLATS DEFLECTOR* I-2-7/8' (73,0 mm) DIA. PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT {TY315) AND PENDENT (TY325) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE WRENCH RECESS (USE ONLY END 'A') FIGURE2 W-TYPE6 SPRINKLER WRENCH WRENCH RECESS t PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE3 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation The TYCO Series TY-B, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) to 3/32 in. (2,4 mm) for the 360°F (182°G) tempera- ture ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N•m). Recessed Pendent Sprinklers The Series TY-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N•m). Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 15 or Style 20 Closure over the Series TY-8 Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TY-8, 5.6 K-factor, Upright (fY315) and Pendent (fY325) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) Thereafter, annual inspections per NFPA 25 are required; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. TFP152 Page 3 of4 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER FITTING 2-1/4' DIA. (57,2 mm) 3/8±5/16' ,?I~ I I MOUNTING 5/8" (15,9 mm) FLUSH {9,5±7,9mm) v~ SURFACE c:r;=!:z::i;:~ CLOSURE SERIES TY-8 MOUNTING PLATE 1-3/8" (34,9 mm) 3/4" (19,1 mm) FIGURE4 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8' DIA. (73,0 mm) FACE OF SPRINKLER FITTING 2-1/4" DIA (57,2 mm) 5/16±1/4' (7,9±6,4 mm) 1/2" (12,7 mm) FLUSH I /~~&JI:::;:;;;;;;;~ MOUNTING SURFACE =l_J 1/8" (3,2mm) -+--------+ CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) 7/8" (22,2 mm) TY-8 PLATE FIGURES SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY (TY325) WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-8 Upright or Pendent (specify) Sprinkler, SIN (specify), K=S.6, Standard Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table B) Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify•) finish, PIN (specify•) Specify: Style 20 Recessed Escutch- eon with (specify•) finish, P/N (specify•) • Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP152 Page4 of 4 BULB SPRINKLER RNISH !71 K SPRINKLER TEMPERATURE LIQUID I I POLYESTER0 TYPE RATING COLOR NATURAL CHROME BRASS PLATED 135°F (57°C) Orange UPRIGHT 1 ss°F (68°C) Red (TY315) and 175°F (79°C) Yellow PENDENT 200°F (93°C) Green 1, 2, 3, 4, 5, 6, (TY325) 2a6°F (141 ·q 5.6 Figure 1 Blue 1/2 in. 360°F (182°C) Mauve NPT 13s•F (S7°C) Orange RECESSED 1ss°F (6a0c) Red PENDENT 175°F (79°C) Yellow 1, 2, 3, 4, (TY325)* Figures 4 and 5 200°F (93°C) Green 2a6°F (141°C) Blue 1, 2 Notea: 1, Ust&d by Underwriters Laboratories, Inc. (UL} 2. Listed by Underwriters Laborato,lo,;, Inc. fo, use In Canada (C-UL) 3. Approved by FIIA Global (FI\A Approvals) 4. Approved by the Loss Prevention Certification Soard (LPC8 Rel, No. 007k/03) 5. VdS Approved (For details contact Johnson Controls, Ensch&de, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377) 6. Approved by the Loss Prevention Certlficallon Board (LPCB Ref. No. 094a/05) 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, tho sprinklers are UL and C-UL Listed as CorToalon-Ro,;lstant Sprinklers. • Installed with Style 15 (1/2 In. NPT) 5/8 In. Total Adjustment Recessed Escutcheon, as applicable •• Frame and deflector only N/A -Not AppPcablo TABLE A SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS P/N* 77 -XXX -X -XXX I I SIN SPRINKLER FINISH 570 5.6K UPRIGHT (1/2 in. NPn TY315 1 NATURAL BRASS 571 5.6K PENDENT (1/2 in. NPn TY325 3 PURE WHITE (RAL9010) .. POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER 5 JET BLACK (RAL9005) POLYSTER 9 CHROME PLATED ' Use suffix "I" for ISO 7·1 connection; for example, 77-570-4-175-1 0 Eastern Hemisphere sales onty ••• OPEN indicates aprinkler assembly without Glass Bulb, Button. and Sealing Assembly TABLES SERIES TY-8 UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 1400 Pennbrook Parkway, lanadale, PA 19448 I Telephone +1-215-382-0700 MA..TIONAi. ~ PfW1T!CTION ASSOCIATtON ~d NFPA ■,• ,.i•.ct tt■d.-natk• of NMtoml '""• Ptot<Ktkin AaAoc.l■tkin, f'lllOtr,ll••• .. .t:ter.db~O,OUPont 135 155 175 200 286 360 000 TEMPERATURE RATINGS 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 2a6°F (141°C) 360°F (182"C) OPEN ... Johnson ~Jg, Controls