Loading...
HomeMy WebLinkAbout7750 EL CAMINO REAL; A; FPC2021-0160; PermitPERMIT REPORT · Fire Permit Print Date: 01/28/2022 Job Address: 7750 EL CAMINO REAL, # A, CARLSBAD, CA 92009-8517 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel#: Valuation: Occupancy Group: #of Dwelling Units: 2161241600 Track#: $178,109.44 Lot#: Project#: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: SWEET GREEN -SPRINKLER Tl {27 HEADS) Applicant: TITAN FIRE PROTECTION INC ANTONIO ROSARIO 1341 DISTRIBUTION WAY, # 14 VISTA, CA 92081-8843-SAN DIEGO (619) 306-6926 FEE FIRE NFPA 13 or 13R System 7-100 heads Total Fees: $553.00 Fire Department Total Payments To Date: $553.00 (cityof Carlsbad Permit No: FPC2021-0160 Status: Closed -Finaled Applied: 08/26/2021 Issued: Fina led Close Out: 01/28/2022 Inspector: Fina l Inspection: FPContractor: TITAN FIRE PROTECTION INC 1341 DISTRIB UTION WAY, # STE 14 VISTA, CA 92081-8843 {760) 295-3436 Balance Due: AMOUNT $553.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov . ,, ~re l'l'ott!ct1brrebnttactor-llcense-#'!l8'Z80'' FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 21669 -Sweet Green 77~0 El Camino Real, Bldg C r, Suite A Carlsbad CA, 92009 \IIKINGi TECHNICAL DATA Page 1 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to ½" (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assem- bly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is cULus Listed as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS L®"' cULus Listed: Category VNIV ~ FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 ~ VdS Approved: Certificate G4080021 LIQ LPCB Approved: Certificate number 096e/12 I Ii\ WARNING. cancer and Rep,oduclive Harm-I L_D www P65warn,ngs ca gov ( E CE Certified: Standard EN 12259-1 , EC-certificate of conformity 0786-CPD-40249 @ CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) $-MED Certified: Standard EN 12259-1 , EC-certificate 0832-MED-1003 Refer to Approval Chart 1 Design Criteria for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating "250" stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). tMetric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-C51000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Form No. F _103005 18.10.11 Rev 18.2.P65 Replaces Form No. F _ 103005 Rev 18.2 (Added P65 Warning.) Page 2 of 7 \IIKINGi TECHNICAL DATA MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 K5.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-C51000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 or Stainless Steel UNS-S30400 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. VK462 -13503A for Brass finish and 13503JN for ENT finish. VK463 -HP Base Part No. 13667 A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E For example, sprinkler VK463 with a 155 °F (68 °C) temperature rating = 13667 AB. Standard Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper= E-/B, Painted White= M-/W, Painted Ivory= M-/1, Painted Black= M-/B Temperature Suffix: 135 °F (57 °C) UL (139 °F (59 °C) FM and LPCB) = A, 165 °F (74 °C) = C For example, cover 13504 with a Polished Chrome finish and a 165 °F (74 °C) temperature rating= 13504FC. Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Temperature Suffix: 135 °F (57 °C) UL (139 °F (59 °C) FM and LPCB) = A, 165 °F (7 4 °C) = C For example, cover 21876 with a 165 °F (74 °C) temperature rating= 21876C NOTE: The cULus Listings for the square cover plate 15394 are for the 135 °F (57 °C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 14047W/B (available since 2006), or 8. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a ½" ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F _103005 18.10.11 Rev 18.2.P65 Page 3 of 7 'JIKINGi TECHNICAL DATA MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 KS.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 135 °F (57 °C) cULus Ordinary 155 °F (68° C) 100 °F (38 °C) 1----......:.-......:. ______ 13504 or 218765 13642 or 218755 15394 Red 139 °F (59 °C) FM and LPCB Intermediate 175 °F (79° C) 150 °F (65° C) 165 °F (74 'C) 13504 or 218765 13642 or 218755 15394 Yellow Intermediate 200 °F (93° C) 150 °F (65° C) 165 'F (74 'C) 13504 or 218765 13642 or 218755 15394 Green Cover Plate Finishes•: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Sprinkler Finishes: Brass and ENT Corrosion Resistant Coatings•: ENT Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. • The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. 5 Stainless Steel versions are not available with any finishes or paint. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers Form No. F_103005 18.10.11 Rev 18.2.P65 3-5/16" (84 mm) Figure 2: Square Cover Assembly 15394 Page 4 of 7 \IIKINCG TECHNICAL DATA MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 KS.6 The Viking Corporation, 21 0 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Maximum Listings and Approvals• SIN Size K-Factor Water Working (Refer also to Design Criteria) Base Part No.' Inch U.S. metric2 Pressure cULus5 NYC VdS' LPCB E • 12 mm Standard Response Applications 13503A VK462 1/2' 5.6 80.6 175 psi (12 bar) AY1, CZ1 AY1 , BZ1 AY1, CZ18 AY3 @ 19785A VK462 1/2" 5.6 80.6 175 psi (12 bar) AY2, CZ2 21356A VK462 -15 5.6 80.6 175 psi (12 bar) Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1,BX1, AV1, BX16 AS3, BT3 13503JN11 VK462 1/2" 15 5.6 80.6 175 psi (12 bar) AV1, BX1, AV1, BX16 AS3,BT3 13667A VK463 1/2" 15 5.6 80.6 250 si 17.2 bar 3 AV1, BX1 AV1, BX1 6 Sprinkler Temperature Ratings A· 155 °F (68 °C) B -175 °F (79 °C) and 200 °F (93 °c) C • 200 °F (93 °C) Cover Plate Assembly Temperature Ratings'·" S -135 °F (57 °C) cover 21876 or 21875 (large diameter) T -165 'F (74 °C) cover 21876 or 21875 (large diameter) V -135 °F (57 °C) cULus Listed cover 13504, 13642 (large diameter), or 15394 (square cover plate) X -165 °F (74 'C) cover 13504, or 13642 (large diameter) Y -135 °F (57 °C) cover 13504 LPCB Approved as 139 °F (59 ·c; Z -165 °F (74 °C) cover 13504 Footnotes AY2,CZ2 AY3 Cover Plate Assembly Finishes•• 1 -Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 2 -Brass 3 -Stainless Steel 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 The Water Working Pressure rating is stamped on the deflector. • This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. 7 VdS Approved, standards VdS 2344:2005-12, VdS 2100-25:2008-01, and EN 12259-1 :1999 + A 1 :2001 + A2:2004 + A3:2006, Certificate G4080021. • CE Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249. • The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label. 10 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. 11 cULus Listed as corrosion resistant. " MED Certified, Standard 12259-1, EC-certificate 0832-MEO-1003. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. Form No. F _103005 18.10.11 Rev 18.2.P65 \IIKINGi TECHNICAL DATA Page 5 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 KS.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1-----------·---~~-----------------·------~ --··- t J: · , Ir , ; I ',;' r I : ; , I.' I JI (, .' J r 1 ,, r 1,) , ~), i , 1 I f,, r r i I) cULus ust;na Requirements: Mirage® Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed as quick response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard, Group II. • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be Installed In neutral or negative pressure plenums only. YdS Approval Requirements: a) The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. b) This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. c) Follow installation guidelines of current standards, CEA4001VdS and EN12845. These sprinklers can only be installed in LH and OH occupan-cies, except in OH4. NOTES: Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type 'Domed-CCP' shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation: 1. Prepare the sprinkler key. 2. Remove the plastic cover. 3. Hold the sprinkler with the wrench and fasten it. 4. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_103005 18.10.11 Rev 18.2.P65 \IIKlt«G TECHNICAL DATA Page 6 of 7 MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 KS.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com I ~ -~ ------------------~------- ;' ;);)(')'/:ii r,!l-tf 1 ) (; /ii) i ~; ,,' • , I 11 ,II 1 .,,. .,,,~ r 1 t.1~);1 ,.,;,,•_,f1,,.,,',,_,J,., •[,1 ,1', fl' _,:)r1!l.'t.,r /,"',_,.) I~'' '• Ir I \( Sprinkler Base Part No.' SIN NPT Thread Size Nominal K-factor Maximum Water Working Pressure Inch J mm U.S. I metric' 13503A VK462 112" I 15 5.6 I 80.6 175 psi (12 bar) Sprinkler Temperature Ratings A -155 °F (68 °C) a -175 °F (79 °C) and 200 °F (93 °C) Cover Plate Assembly Temperature Ratings'·• Y -139 °F (59 °C) cover 21875 or 21876 Z -165 °F (74 °C) cover 21875 or 21876 W -139 °F (59 °C) cover 13504, 13642 (large diameter), or 15394 (square cover plate) X -165 °F (74 °C) cover 13504, 13642 (large diameter), or 15394 (square cover plate) Footnotes FM Approvals3 (Refer also to Design Criteria below.) AW1, BX1,AY2. 822 Cover Plate Assembly Finishes5 1 -Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 2 -Stainless Steel ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additiona approvals. • The 139 °F (59 °C) cover has an orange label. The 165 °F (74 °C) cover has a white label. 5 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. I I J ) I' JI I ( ; ) I I , I ",I ( : ,'} I I 1 l•J, 1: I I 1 , r 1 _,' 1 J EM Approval Requirements: Viking Concealed Pendent Sprinkler VK462 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NF PA criteria. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F _103005 18.10.11 Rev 18.2.P65 Page 7 of 7 I TECHNICAL DATA MIRAGE® STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 KS.6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047WB** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047WB** NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047WB** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Step 2: t t 2-1/4" (57 mm) diameter opening required in the ceiling. Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Sprinkler frame arms Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) 1/2" (15 mm) NPT \ NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16" (21 mm) below the sprinkler body. 2-1/16" (52 mm) Minimum 2-3/4" (70 mm) or 3-5/16" (84 mm) Figure 4: Sprinkler Dimensions and Cover Installation Form No. F_1 03005 18.10.11 Rev 18.2.P65 Replaces Form No. F _ 103005 Rev 18.2 (Added P65 Warning.) TECHNICAL DATA Page 1 of 6 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired . In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS ~®"' cULus Listed: Category VNIV ~ FM Approved: Class Series 2000 8 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 ,LJO.,, LPCB Approved: Certificate 096e/06 It\ WARHING. Cancer end Reproductive Harm-~ www.P65Waml"9$.ca.p ( E CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 @ CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) @ MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1 /2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap -ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G FormNo.F_033314 19.02.21 Rev19.1 Replaces Form No. F _033314 Rev 18.1.P65 (Removed F-1 Escutcheon.) Page 2 of 6 TECHNICAL DATA MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B. B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) C. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) ** A ½" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F _051808. Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) 8 . Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact.The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap--....;;.. Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F _033314 19.02.21 Rev 19.1 [ Page 3 of 6 TECHNICAL DATA MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES I -- I - ,:,11 1 : ,: l I ,('1;1 ! 111 1, ' :., 1 1 r 1 ;; I , 1 f I 'Jr 1 1 r 1 1 l i' I 1 (1:r11 1rr1 1 r 'J 1 ,, , r, i I ,. 1 1 1;..... , r t, 1 1 1 , ~ .1 , 1 ! r 1 ~J 1 , . , I , ,-,. r .II• J f r ,1 I , ., ,; : 1 l •, ! ' ( ~) 11 ', , I I I I l'J I , I I I:, , I I" I I , I Ordinary 135 °F (57 °C) 1 oo °F (38 °c) Orange Ordinary 155 °F (68 °C) 1 oo °F (38 °c) Red Intermediate 115 °F (79 °c) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (1 01 °c) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes ' The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. Sprinkler wrench 13655W/B** for recessed pendent sprinklers •• A 1/2" ratchet is required (not available from Viking) For ENT coated automatic sprinklers, the waterway is coated. Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F _033314 19.02.21 Rev 19.1 Page 4 of 6 \IIKlm TECHNICAL DATA MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (KS.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Base Thread Size Part SIN Sprinkler Number' Style NPT BSP 12979 VK302 Pendent 1/2" 15mm 19780 VK302 Pendent 1/2" 21354 VK302 Pendent 15 mm Approved Temperature Ratings A-135 'F (57 'C), 155 'F (68 'C), 175 'F (79 'C), 200 'F (93 'C), 286 'F (141 'C) Nominal Overall K-factor Length U.S. metric' Inches mm 5.6 80.6 2-1/4 58 5.6 80.6 2-1/4 58 5.6 80.6 2-1/4 58 Approved Finishes Listings and Approvals' (Refer also to Design Criteria.) cULus• VdS LPCB A1Z,B1Y,O2,C2X A1 A1Z,B1Y D1Z,C1Y 01 Approved Escutcheons X -Standard surface-mounted escutcheon or the Viking Micromatice> Model E-1 Recessed Escutcheon en:• 03 03 B -135 'F (57 'C), 155 'F (68 'C), 175 'F (79 'C), and 200 'F (93 'C) 1 -Brass, Chrome, White Polyester"·•, Black Polyes- ter'·• 2-ENT° Y -Standard surface-mounted escutcheon or recessed with the Viking Micromatic"' Model E-1, E-2, or E-3 Recessed Escutcheon C -155 'F (68 'C), 175 'F (79 'C), and 200 'F (93 'C) D -155 'F (68 'C), 175 'F (79 'C), 200 'F (93 'C), 286 'F (141 'C) 3-Chrome Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. Z -Standard surface-mounted escutcheon 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. • Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. • cULus Listed as corrosion-resistant. • Other colors are available on request with the same Listings and Approvals as the standard colors. 7 CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-S0021. • MED Certified, Standard EN 12259-1, EC-0832-MED-1003. cULus Ustjng Reaujrements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. FormNo.F_033314 19.02.21 Rev19.1 'JIKINGi TECHNICAL DATA Page 5 of 6 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Base Part Number' SIN Sprinkler Style Thread Size Nominal K-factor Overall Length FM Approvals' BSP U.S. metric2 Inches mm (Refer also to Design Criteria.) 18021 80.6 2-1/4 A1Z,B1Y Approved Temperature Ratings A-135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °c), 286 °F (141 °C) B -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C -155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C) D -155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Approved Finishes 1 -Brass, Chrome, White Polyester', and Black Polyester' 2-ENT5 Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. Approved Escutcheons X -Standard surface-mounted escutcheon or the Viking Micromatic., Model E-1 Recessed Escutcheon Y -Standard surface-mounted escutcheon or recessed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon Z -Standard surface-mounted escutcheon 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. • Other colors are available on request with the same Approvals as the standard colors. 5 FM approved as corrosion proofing for corrosive environments. I IJ. ,I(" I (,,'I I '1 1·' ; ,',I 1 J r I r I!;, 1 ,, "1, I r i, ) 11 ,' , ) EM Approval Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance Information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. FormNo.F_033314 19.02.21 Rev19.1 Page 6 of 6 'JIKINGi TECHNICAL DATA MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (KS.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1/2" Installed with a standard 1/8" surface-mounted escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum Figure 3: Sprinkler Dimensions with a Standard Escutcheon t 5 I Installed with a Model E-1 Recessed Escutcheon 1-1/8" (29 mm) Min. Installed with a Model E-2 Thread-on Recessed Escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 1-1/8" (29 mm) Min. Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F _033314 19.02.21 Rev 19.1 Replaces Form No. F _033314 Rev 18.1.P65 (Removed F-1 Escutcheon.) '\IIKINGi TECHNICAL DATA Page 1 of 4 MICROFAST• QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlklnggrouplnc.com 1. DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS c@• cULus Listed: Category VNIV ~ FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric .. ) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) I ft\ WARNING. c-end R~•· Harm-I L.l::!, www.P65wam,ngs.ca.gov 'cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers· Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap -ENT plated Ordering Information: {Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-18, and ENT = JN Temperature Suffix (°FrC): 135°/57° = A, 155°/68° = B, 175•n9• = D, 200•193• = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 •c temperature rating= Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A {available since 1971 ) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F _052114 19.10.14 Rev 19.1 Replaces Form No. F _052114 Rev 17.1.P65 (Added ENT; updated FM language.) "IKINGi TECHNICAL DATA Page 2 of 4 MICROFAST., QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlklnggrouplnc.com 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfas~ Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1 AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 135 °F (57 °C) 100 °F (38 •q Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings1: White Polyester. Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes ' The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied lo the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coaled automatic sprinklers. the waterway is coaled. Protective Sprinkler Cap----~ Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F _052114 19.10.14 Rev 19.1 Page 3 of 4 '\IIKINGi® TECHNICAL DATA MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (KS.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlkinggrouplnc.com Approved Temperature Ratings Approved Finishes A -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °c), and 286 °F (141 °C) B -155 °F (68 °C). 175 °F (79 °C). 200 °F (93 °C), and 286 °F (141°C) 1 -Brass, Chrome, White Polyesters6, and Black Polyester66 2-ENT6 Footnotes 'Base part number is shown. For complete part number. refer to Viking's current price schedule. 'Metric K-fador measurement shown is when pressure is measured in Bar. When pressu-e is measured in kPa, <ivide lhe melric K-faclo, shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. ' Listed by Undefwrilers Laboratories Inc. for us in the U.S. and canada ' Other cok>rs are available on request with the same Listings and Approvals as the standard colors. • cULus Listed as corrosion resistant ' Meets New York City requirements. elfectMt July 1, 2008 • Accepted for use, City of New York Board of Standards and Appeals, calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E. Vol. 16. cULus Listing Requirements: The Viking Microfastt' Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F _091699. Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F _05211 4 19.10.14 Rev 19.1 '\IIKINGi TECHNICAL DATA Page 4 of 4 MICROFAST® QUICK RESPONSE UPRIGHT SPRINKLER VK300 (KS.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.v lklnggrouplnc.com Approved Temperature Ratings A-135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B -155 °F (68 °C), 175 °F (79 "C), 200 °F (93 °C), and 286 °F (141°C) Footnotes Approved Finishes 1 -Brass, Chrome, White Polyester5, and Black Polyester5 2 -ENTS ' Base part number is shown. For complete part number, refer lo Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pres.sure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. 5 Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. EM Approyal Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum watef supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and denector distance below the ceiling. NOTE: The FM Installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F _052114 19.10.14 Rev 19.1 Replaces Form No. F _052114 Rev 17.1.P65 {Added ENT; updated FM language.) Page 1 of 6 QUICK RESPONSE 'JIKINCG TECHNICAL DATA DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlklnggrouplnc.com 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry sys- tems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS ,@■ cULus Listed: Category VNIV ~ FM Approved: Classes 2013 and 2015 NYC Approved: MEA 89-92-E Volume 15 I ,1\ WARNING: Cancer and Reproductive Harm-I ~ www.P65wam.,,gs ca_gov Refer to Approval Chart 1 and Design Criteria on page 105d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1 • NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. • Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Covered by the following U.S. Patents: 8,636,075 and 10,220,231 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraulic Steel Tube Support {Internal): Stainless Steel UNS-S30400 Barrel: Steel Pipe UNS-G10260. Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: {Also refer to the current Viking price list.) Form No. F _031793 19.10.14 Rev 19.2 Replaces Form F_031793 Rev. 19.1 ( AMPrl FNT· 11nti:::itPrl FM l:::inn11:::inP \ Page 2 of 6 \IIKINGi I TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlkinggrouplnc.com Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A" dimension) to sprinkler base part number. Order in a specific length noted as the "A" dimension. The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) for the adjustable standard style, 3" to 47" (76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a "made-to-order" basis: Recessed Dry Pendent up to 65-1/2" (1,664 mm). Adjustable Standard Dry Pendent up to 63-1 /2" (1,613 mm). Plain Barrel Dry Pendent up to 65" (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK176 with a Chrome finish and a 155 °F (68 °C) temperature rating, and "A" length of 10" = Part No. 08383UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 07297W/8 (available since 1991) B. Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) .. A ½" rat.chet is required (not available from Viking). Sprinkler Guard: Chrome, with no listings or approvals, for installation on dry pendent sprinklers made after May 1994 only (Part No. 08954). Replacement Escutcheons: A. Adjustable Standard Dry Escutcheon: Base Part No. 07741 B. Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to exli1guish or control the fire. 6. INSPECTIONS, TESTS & MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Quick Response Dry Pendent Sprink- ler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty. refer lo Viking's current list price schedule or contact Viking directly. St ep l: Carefully slide the wrench sidewoys oround the sprinkler deflector. \.Jr-ench Flo.t Protectiv e Spr-inkler- Shielci VIKING ,,.., Q Figure 1 : Standard Sprinkler Wrench 07297W/B Sprinkler \Jrench 07565\JIB•• MUSt be used For instolling recessed dry sprinklers ~ Step 2: Corefully press the wrench upword ond turn slightly to ensure engogerwnt with the sprinkler wr ench Flo ts. ••A 1/2' ratchet~ required (Not ovail- oble tr-OM Viking) CT ' _i I • I L ...... r l l Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers Form No. F _031793 19.10.14 Rev 19.2 Page 3 of 6 '\IIKINCG TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlklnggrouplnc.com TABLE 1. AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coatlngl-': White Polyester and ENT in all temperature ratings Footnotes ' The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant PolyHter and ENT coatings have passed the standard corrosion test required by the approving agencies Indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof. Prior to Installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring Is exposed on sprinklers with Polyester and ENT coatings. • When installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time Is not in itself an Indication of corrosion and should not be treated as such. All sprinklers Installed In corrosive environments should be replaced or tested as described In NFPA 25 on a more frequent basis. For 'A' DiMension: I. DeterMine the distonce f'roM the f'oce of' the tee t o the f'inished ceiling. 2. Round to the neorest 1/2' (12.7 MM) between 1-1/2' ond 45-1/2' <38.1 MM ond 1,156 MM). NOTE: The def'lector will be loco ted opproxiMo tely 3-7 /16' (87.3 MM) below the ceiling. with 1' (25.4 MM) upword ond 1' (25.4 MM) downword odjustMent. A l~-- Finished Ceiling 1-1/2'--t-~ (38.1 MM) dioMeter 3-1/16' (77.8 MM) Deflector o t MiniMuM distonce below ceiling. MiniMUM ceiling opening dioMeter: 1-3/4' (44.5 MM) MoxiMuM ceiling open ing diOMeter: 2-1/4' (57 MM). 13/16' (20.6 MM) --Sleeve f'inish Motches escutcheon. Deflector O t MOXiMUM distonce below ceiling. NOTE: To loco te t he def'lector o t the MiniMuM distonce below the ceiling, with no downword odjustMent o.vo.ilo.ble, order the dry pendent sprinkler 1' <25.4 MM) shorter thon the 'A' diMension. NOTE: To locote the def'lector ot the MoxiMuM distonce below the ceiling, with no do wnword odjustMent a. vo.ilo.lole, order the dry pendent sprinkler 1 • (25.4 MM) longer thon the 'A' diMension. Figure 3: Adjustable Standard Dry Pendent Sprinkler Form No. F_031793 19.10.14 Rev 19.2 Page 4 of 6 QUICK RESPONSE \IIKINGi TECHNICAL DATA DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.viklnggrouplnc.com Sprinkler Thread Size Nominal K-Factor Order Length Increment Listings and Approvals' SIN Style (R•fer also lo DH Criteria be-. Base Part No.' NPT BSP U.S. metric' Inches mm cULus$ NYC' VdS LPCB CE 08383U VK176 Adjustable 1" 5.6 80.6 112· 12.7 A1 ,A5 A1 16457U Standard 25mm 80.6 1/2" 12.7 A1,A5 08385U Adjustable 1· 5.6 80.6 1/4" 6.35 B2,B6 B2 VK180 16453U Recessed -25mm 80.6 1/4" 6.35 82, 86 08387U VK172 Plain 1' 5.6 80.6 1/2" 12.7 A3 A4 16455U Barrel 25mm 80.6 112· 12.7 A3 Approved Finishes and "A" Dimensions • Approved Temperature Ratings 1 -Chrome or White Polyester' sprinkler with a Chrome or White Polyester Sleeve and Escutcheon A· 155 °F (68 °C), 175 °F (79°C), 200 "F (93 ·c), and 286 "F (141 •q 8 • 155 °F (68 °C), 175 °F (79°C), and 200 "F (93 "C) with "A' dimensions 1-1/2" to 45-1/2" (38.1 mm to 1.156 mm) 2 -Chrome or White Polyester' with "A" dimensions ~1/4" to 47-1/2" (82.5 mm to 1,207 mm) 3 • Chrome, Brass, White Polyester', or ENT7 with "A" dimensions 3" to 4T (76.2 mm to 1,194 mm) 4 -Chrome or Brass with "A" dimensions 3" lo 4T (76.2 mm to 1,194 mm) 5 -ENT' sprinkler with an ENT' Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) 6 -ENT' with "A" dimensions ~1/4" to 47-1/2" (82.5 mm to 1,207 mm) Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. • This chart shows the listings and approvals available al the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. s Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15. 7 cULus Listed as corrosion resistant. NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-81 tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklefs. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F _031793 19.10.14 Rev 19.2 Page 5 of 6 '\IIKINGi I TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlklngcorp.com h h lkl I I I I I I I . . Sprinkler Base SIN Part No.1 __ 08_3_8_3_U_-1 VK176 16457U Style Adjustable Standard 08385U i----1-64-5-3-U----t VK180 Adjustable Recessed t--_08_3_8_7U_---t VK172 16455U Plain Barrel Approved Temperature Ratings A-155 °F (68 "C), 175 °F (79 °C), 200 °F (93 "C), and 286 "F (1 41 •q B -155 °F (68 °C), 175 °F (79°C), and 200 °F (93 °C) Thread Size Nominal K-factor Order Len h Increment NPT BSP U.S. metrlc3 Inches mm FM Approvals4 (Refer alw to Design Crlwla below.I 1· 5.6 80.6 1/2" 12.7 A1 25mm 80.6 112· 12.7 A1 1· 5.6 80.6 1/4" 6.35 B2 25mm 80.6 1/4" 6.35 B2 1· 5.6 80.6 1/2" 12.7 A3 25mm 80.6 1/2" 12.7 A3 Approved Finishes and "A" Dimensions 1 -Brass, Chrome, White Polyester, or ENT6 sprinkler with a Brass, Chrome, White Polyester, or ENT6 Sleeve and Escutcheon with "A" dimensions 1-1/T to 45-1/2" (38.1 mm to 1,156 mm) 2 -Brass, Chrome, White Polyester, or ENP with "A" dimensions 3-1/4" to 47-1/'Z' (82.5 mm to 1.207 mm) 3 -Brass, Chrome, White Polyester, or ENT6 with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. • K-Factor applies for standard lengths ("A" Dimensions indicated above). ' Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. • This chart shows the FM Approvals available at the lime of printing. Other approvals may be In process. Check with the manufacturer for any ad-ditional approvals. 5 FM approved as corrosion resistant. NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-81 tees. When selecting other CPVC fittings , contact Viking Technical Services. EM Approval Reautceroeots; The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (indud- ing 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design. ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F _ 091699 -Care and Handling of Sprinklers. Also refer to Form F _080614 for general care, installation, and maintenance Information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and s1andards, whenever applicable. MiniMUM ceiling opening, 2-1/8' (54 MM) dioMeter. MoxiMUM ceiling opening: 2-112· (63.5 MM> dioMeter. For 'A' Dil'lension I. Deter-Mine the olistonce froM foce of tee to the finished ceiling. 2. Round to neorest 1/4' <6.35 MM) between 3-1/4' <82.5 MM) onol 4 7-1/2' (1,207 MM), NOTE, Sprinkler will be recessed opproxiMo tely 5/16' <7.9 MM) obove the finished ceiling with 5/8' <15.8 MM) verticol ooljustMent ovoiloble. Dutsiole olioMeter, 1-5/16' (33.4 MM) <sane as 1' (25 MM) Schedule 40 pipe>. 'A' DiMension: Deter-Mine the olistonce froM the foce of the tee to the bose of the sprini<ler. 2. Rounol up to the next highest 112· <12.7 MM) lncre- Ment be tween 3' (76.2 MM) o.ncl 47' (1,194 MM). 1-5/8' (48.3 MM) _l_ Figure 5: Plain Barrel Dry Pendent Sprinkler Page 6 of 6 \IIKINCG TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 490S8 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlkinggroupinc.com r--lnsto.ll 1 inch NPT threo.ded / end of dry pendent sprinkler ~-~,....._ ___ _____,.., into the 1 inch NPT outlet 30'F (-l'C) 0 0 0 2o·r <-7'C> 4 <100> o o IO'F (-12'C) 8 (203) I (25.4) 0 O'F <-18'C) 12 <305> 3 <76> 0 -IO'F (-23'C) 14 <356) 4 <102) I <25.4> -20'F <-29'C> 14 <356> 6 <152> 3 (76) -30'F -40"F -so·r <-46"C> 20 <508> 10 <254 6 <152> -60"F <-Sl"C) 20 (508> 10 <254 6 <152> _j Celling 1-1/2' (38.1 MM) --a-~ dio.Meter (Protected Areo.) of o. Mo.lleo.ble iron tee fit ting per ANSI B 16.3 (Clo.ss 150) or co.st iron threo.ded tee fitting per ANSI 16.4 (Clo.ss 125) only. MiniMUM ceiling opening diaMeter: 1-3/4' (44.5 MM) Mo.xiMuM ceiling opening dio.Meter: 2-1/ 4 • (57 MM). ,--------Seo.I the cleo.ro.nce 3-1/16' (77.8 MM) Sleeve finish --Mo.tches escutcheon spo.ce o.rounci the sprinkler to o. void leo.k- o.ge o f o.ir Into the protected o.reo. o.nd consequent forMo.tion of condenso.te a.round the fro.Me, which could inhibit opero. t ion or co.use preMo.t ure opero.- tion. Refer to Figure 7 below. If huMidity o.nd teMp- ero. ture differ entio.l co.uses condenso.tion on the exposed dry sprinkler, consider wro.pping t he exposed bo.rrel with insulo. tion, foo.M insulo. ting to.pe, or equivo.lent. Deflector o. t MiniMuM disto.nce below ceiling Deflector o.t MaxlMuM distance below ceiling •The protected o.reo. refers to the o.reo. below t he celling. The O.Mbient teMpero. ture is the teMpero. ture o. t the discho.rge end of the sprinkler. Up to 2' (50.8 MM) adjustMent available. Note, To loco.te t he deFlector at the MiniM1..1M dis tar,ce below the ceiling. with no upwo.rd adjustMent avail- able, order the dry pendent sprink-ler 1· (25.4 MM) shorter than the "A" diMension. Note, To loco."te "the deflector at the MOXiMUM distance below the celling, with no downward o.djustMent nvail- o.ble, order the dry pendent sprink-ler 1 • (25.4 MM) longer than the "A· diMension, For protected o.reo. teMpero.tures tho.t occur between the vo.lues listed, use the next cooler teMpero.ture. ••The MlniMuM required bo.rrel length is not the so.Me o.s the 'A" diMension. Refer to Figures 3-5 for the "A" diMension. NOTE: Exposed MiniMUM bo.rrel lengths o.re inclusive up t o 30 Mph wind velocities, Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler Is Shown) Form No. F _031793 Seal (or equivo.lent Method) Cleo.ranee Opening Dry Sprinkler Seal on the Exterior of the Ceiling Insulated Ceiling Seo.I Dry Sprinkler Seal \./lthin the Ceiling Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) 19.10.14 Rev 19.2 Replaces Form F _031793 Rev. 19.1 IArlrlPrl l=NT· 11nrl~IPl'I FM l~nn11~nP \ SCHEDULE 10 & SCHEDULE 40 "'~ I FM APPROVED ANO UL LISTED SPRINKLER PIPE --·------- Bull Moose Tube's• Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube• made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's• Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 sta.ndards.All products are stencilled to meet FM & UL specifications. c®usLISTED ~ APPfllMII m -~ OAFU Nf1IJ(' ~-............. -----. SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILL.ED BUNDLE 51.ZE (IN) (IN) (IN) CRR•• WEIGHT/FT WEIGHT SIZE 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-1/4 -J[_ 1.660 JC 1.442 ·Jr:-=_ 9.91 7C 1.811bslft JC' 2.s18 =:Jc= 61 1-1/2 1.900 1.682 7.76 2.09 lbslft 3.053 61 2 ~I[~ 2.375 JC 2.157 -L~ 6.27 =r 2.64 lbs/ft IL: 4.223 ""=:Jc= 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft S.893 30 3 _Jl_ 3.500 _:L 3.260 _JL_ 3.54 _J[ 4.34 lbs/ft ll 7.957 ~L__ 19 4 4.500 4.260 2.50 5.62 lbslft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. 1.0. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 ~r= 1.660 -IC 1.380 ~c_ 1.00 =11 2.27 lbs/ft JC 2.918 _:C_. S1 1-112 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 : JL: 2.375 _JL 2.067 "Jr-= 1.00 -7[ 3.66 lbstft JC 5.114 =ic 30 2-112• 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 _3• ___ IL_ 3.500 --ic. 3.068 JL 1.00 -7 7.58 lbJ/ft IL 10.783 =ic..= 19 4• 4.500 4.026 1.00 10.80 lb.sift 16.316 19 •Only IYlilalllt Iii Casa Grllldt. Al • •cocr~ Rtsls~ R.ltlo ptr latt1t UL OlrtctOl'f LK1lng PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to Installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from Indentations and projections from the end of the pipe to the groove. All loose paint, scale. dirt. chips. grease, and rust must be removed prior to installation. Failure to take these Important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ~Ot!!J auu.-...-.-- For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clatbon Road Chesterfield. MO 6301 7 G«ald, MO Kent.WA Casa Grande AZ www.bullmoosetube.com sales@bullmoosetube.com Dallas, TX M~OH EDDYTHREAD 40® ~£>· I A LIGHTWEIGHT SCHEDULE 40 REPLACEMENT PIPE Bull Moose Tube's• Eddythread 40• is a lightweight replacement for Schedule 40 that has a Corrosion Resistance Ratio of t • c®usLISTED ~ APPIIIMD m NFPA' ~ -o~.--==-=----- ADVANTAGES OF BULL MOOSE TUBE? EOOVTHREAO 409 • Has a Corrosion Resistance Ratio of t .0. • Has a pressure rating of 300 psi. • ls lighter weight than Schedule 40. • Is approved by Factory Mutual and listed by Underwriters Laboratories. • Is produced in accordance to ASTM A 135 and A795 Type E, Grade A. • Can be used with standard Schedule 40 threaded fittings, couplings, and valves. • Is produced from steel with excellent properties of strength and threadablllty. • Can be used in wet. preaction, and deluge type sprinkler systems. • Can be hot dipped galvanized to meet FM's requirement for dry systems. • Offers lower freight costs. • Supplied with EDDY GUARD 11• MIC preventative coating. EOOVTHREAO 40-SPECIFICATIONS NOMINAL PIPE 0.0. 1.0. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR• LB./FT WEIGHT SIZE 1.295 1.083 1.00 1.461 1.860 70 1-1/4 -,c 1.650 _JC 1.418 :JC 1.00 -=:JC 2.070 =r= 2.754 -:i[_ 51 __J - 1-112 1.900 1.654 1.00 2.547 3.468 44 2 -1 ,---2.375 -· 7,- 2.123 :JC 1.00 =-=L: 3.308 :::JC 4.842 =._JC__ 30 •(o,roslotl RtslslMl<t btlo ptt l,tttl UL Olrtcto,y Ustlng PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to Installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt. chips. grease, and rust must be removed prior to Installation. Failure to take these Important steps may result In Improper coupllng assembly, causing leakage. Also, check the manufacturer's Instructions for the specific fitting used. ~oe ~111i11:Xaa:'ftaa~ For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road ~MO 63017 Gerald, MO Kint.WA CasaG,m.AZ. www.bullmoosetube.com salesObullmoosetube.com Dallas. TX MIISOI) OH !S EDDY LITE® THE SUPERIOR LIGHTWALL THREADABLE "'~ I Bull Moose Tube's• Eddylite• is a lightwall threadable pipe manufactured in NPS 1 • through r. Eddylite• is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite• is manufacttired to meet the requirements of ASTM A 135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®usLISTED <8> APPROVED m NFPA. ---o~• .......,...._..*--~ -- 6 AOVANTAGES OF BULL MOOSE Tueee ECCYLITee • Standard outside diameter, unlike some other llghtwall threadable pipe products. • Lighter in weight than Schedule 40. • Superior burst strength and corrosion resistance ratio compared to other llghtwall threadable pipe products. • Exceptionally strong, meets or exceeds ASTM A 135 minimum yield requirements. • Can be used with standard couplings. fittings. and valves. • Freight savings. • Lower sprinkler system costs without compromising service life. • Better hydraulics than Schedule 40. • Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thiclcness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAl STANDARD INSIDE UL UL WEI.GHT WATER PIPE SIZE (IN) 0.0. (IN) DIAMETER (IN) THREADED UNTHREADED PER Ft FILLED t 1.31S 1.137 0.13 7.47 1.260 1.700 1-1/4 __ il 1.660 JC_ 1.482 ~[ 0.08 _j[ 4.79 ][ 1.617 J[ 2.364 1-1/2 1.900 1.712 0.12 4.53 t .967 2.965 2 ~, 2.375 ,r-2.177 jf_ 0.16 --=ic 4.31 J[ 2.617 :=c 4.230 •corrosion Rtilstan<t Ratio ptr latest UL Olttctory L11tlng PIPE PREPARATION BUNDLE SIZE 91 --c 61 6t -r~ J ._____ 37 For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket. pipe surfaces should be free from Indentations and projections from the end of the pipe to the groove. All loose paint. scale. dirt, chips. grease, and rust must be removed prior to Installation. Failure to take these Important steps may result In improper coupling assembly, causing leakage. Also, check the manufacturer's Instructions for the specific fitting used. ~-~ n ~~'1\.811~ For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfleld. MO 63017 Gerald. MO kentWA casa Grandt AZ. www.bullmoosetube.com salesObu.llmoosetube.com Dallas. TX ~OH EDDY FLOW® THE COST EFFECTIVE REPLACEMENT FOR SCHEDULE 10 "1~ I Bull Moose Tube's• Eddy Flo~ is a specially engineered replacement for Schedule t 0, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed {for U.S. and Canada) for roll grooving and welding. As an added benefit. it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow1S-larger ID provides an opportunity for downsizing and further cost savings. c®usLISTED ~ APPNMII m NFPA" ,~\ 0'1FS4 -==-=---.-- ----~ ADVANTAGES OP BULL MOOSE TUBP EOOY FLOW" • Certified to ASTM A 135 and A795 Type E, Grade A. • FM approved for roll grooving and welding for use In wet systems. • UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use In wet dry, preaction, and deluge type sprinkler systems. • Lightweight -saves shipping costs and offers easier handling. • Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. • Can be supplied roll grooved or plain end. • Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. • Supplied with EDDY GUARD 11• MIC preventative coating. NPS O.D. EDDY FLOW-EDDY FLOW-WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR* PER FT. WT. SIZE 1-1/4 1.660 1.530 1.98 1.222 2.019 61 1-1/2 =-.l_ 1.900 7C 1.728 . J[ -3.44 :=JC 1.844 ~L 2.860 ~c 61 2 2.375 2.203 2.78 2.330 3.982 37 2-112 __ --=c· 2.875 -=-L 2.705 -~c 1.66 =ic 2.809 -~c 5.299 _-.-JC 30 3 3.S00 3.334 1.00 3.361 7.144 19 4 --4.S00 ---4.310 ~c ,.oo ::JC 4.968 -=ic 11.290 ~c 19 •corrosion Rtslsrara Ratio ptt lalHt UL DirKtoly lifting PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to Installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips. grease, and ru.st must be removed prior to Installation. Failure to take these Important steps may result In improper coupling assembly, causing leakage. Also, check the manufacturer's Instructions for the specific fitting used. ~~ D -......~naa~ For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clark.son Road Chesterfield. MO 63017 Gerald. MO KentWA c:asa Grand@. AZ www.bullmoosetube.com salesObullmoosetube.com Dallas. TX Masu,y. OH 7 ULTRA EDDY® ~~ I THE SUPERIOR SPRINKLER PIPE Bult Moose Tube's• Ultra Ed~ is a versatile product that can be roll grooved, welded, and used with Press-flt* Products. c®usLISTED <@> APPRIMD w --OAFSA -=-==---................. 'Ii a ADVANTAGES OP BULL MOOSE TUBE:9 ULTRA ECCY., • Certified to ASTM A 135 and A 795 Type E, Grade A. • FM approved for roll grooving and welding for use In wet systems. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preactlon, and deluge type sprinkler systems. • Lightweight -saves shipping costs, offers easier handling. • Multidimensional: Can be used with all Schedule S approved roll grooved, welding and Pressflt• Products for pressures up to 175 psi. • Designed to generic Schedule S tolerances for easy lnterchangeablllty with all approved or listed fittings. • Can be supplied roll grooved or plain end. • With a larger ID than other products on the market today, Ultra Eddy•offers substantial improvements in hydraulics. This Improvement allows for downsizing within the system which offers the opportunity for additional cost savings. • Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS o.o. ULTRA ULTRA EDDY• WEIGHT WATER BUNDLE (IN) (IN) EDOV-(ID) CRR** PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 =_JC 1.660 -=c 1.546 ==-1c 1.40 =7L. 1.107 ~c 1.920 ,c 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 ---ir-2.375 --·1( 2.261 --ir -1.00 --1r 1.604 7L 3.344 ~, 37 • Ptmtll is t lltglrttftd Tlldtmwk of Vlct.1ulk Company of Amtfta •• Conaslon Rtsist,nct Rltlo Ptf llttst UL OlrKtoly Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to Installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from Indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these Important steps may result in Improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ~Dt0 -...~n.aa00//1tlWIII/JJi For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 CJalbon Road Chesterf1eld. MO 63017 Gerald, MO Kint.WA casa Grandt. AZ. www.bullmoosetube.com sales@bullmoosetube.com Dallas, TX M~OH NPS (IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 0.0 (in) j 1 .315 1.660 1.900 2.375 1.0 (.,) . 1 1.201 1.546 1.786 2.261 ULTRA mov-I I .. -Wtii# . -I 0.868 1.107 1.274 1.604 _EilJP-tY . -(b'lt) . --riled -' 1.359 1.920 2.360 3.344 '!!-:---· ~(b'ft), -C.R.R. -I 2.17 1.40 1. 11 1.00 o.o.Gn) 1r 1.660 : r 1.900 2.375 II 2.875 T 3.500 ll -4_:_~~ 1.0. C.,I -71 1.530 : [ 1.728 2.203 JI 2.705 [ __ 3.334 . l I_ ~.310 EOOY R.OW-I! -~Wei!llt ~ ! I 1.222 :I 1.844 2.330 II 2.809 [ 3:36L JL -~.968 ~ Wtlght ~. I n 2.019 ;I 2.860 3.982 JI 5.299 ll 7,144· Jf 11 .290 C.R.R. _::_] 1.98 3.44 J 2.78 JI 1,66 J[ 1.00 ·1_ 1.00 o.o.on) -j 1.315 1.660 1.900 2.375 2.875 3.500 4.500 SCHEDUU r __ J.O.(ll) __ 1 1.097 1.442 1.682 2.157 2.635 3.260 4.260 10 ~~~~] 1.410 1.810 2.090 2.640 3.530 4.340 5.620 1.820 2.518 3,053 4.223 5.893 7,957 1 t .796 C.R..R. ··1 15.27 9.91 7.76 6.27 4.92 3.54 2.50 o.o. (in) _j 1.315 1.660 :1 1.900 1[ 2.375 ----·- . 1.0.Gn)_ 7 1.137 •L 1,482 :L 1.n2 J[ _2.177 EDDYUTr Ii EITlpty~~(~f_ I 1.260 If 1.617 7 I 1.967 1r~2.617 _Wat«-FlledWtight (b1i)~' 1.700 1r 2.364 : I 2.965 11 ~.230 c:R.R. J 0.13 0.08 ; I 0,12 ll -0.16 o:o.on> I 1.295 1.650 1.900 2.375 ~I ~~~ 1.083 1.418 1.645 2.123 1.461 2.070 2.547 3.308 1.860 2.754 3.468 4.842 c®usLISTED I [ C.R.R._ 1 1.00 1.00 1.00 1.00 [ 0.0. (in). II 1.315 r 1.660 1r 1.900 ;r 2.375 lf 2.875 11-3.500 71 4.500 1~ I 1.0. (Ji) JI 1.049 ( 1.380 : r 1.610 :1· 2.067 ll -2.469 Ir 3.068 · 1 l 4.026 ~ l _ Enw Weiglt (b'iij" _l I 1.680 2.270 II 2.720 : l 3.660 Ir 5.800 II 7.580 '1 10.800 Water·FledWel!1lt (b'ft); I 2.055 2.918 II 3.602 '. ( 5.114 II 7.875 1l 10.783 I 1~J16 Af1ID'BI I CJtR. 11 1.00 1.00 ·:1 1.00 If 1.oo_JL 1.00 II 1.00 I 1.00_ W_A_~~ ~~ For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 salesObullmoosetube.com n 1819 Clat1c.son Road Chesttffleld.MO G«ald, MO Kent.WA Cesa Grandt. Al. Dallas, TX ~OH auu.. ...... -n.aa~ 63017 9 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDY-0.868 91 t,659 1,896 1,975 SCHEDULE 10 1.410 91 2,695 3,079 3,208 , Ir EDOYUTE'" 1.260 91 2,408 2.752 2.867 1.461 70 2,148 2,454 2,557 1.680 10 2,470 2,822 2,940 1.107 -]-61 -:r 1,418 ---ir 1,621 _--=-ii--_ 1,688 1.222 "J 61 j[ 1,565 --J[ 1,789 :_ _I[_~ 1,864 ,.,, .. I SCHEDULE 10. ,i 1.810 j[ 61 :f _ 2,319 _JL 2,650 ~JL=._ 2,760 r-"""'-UIIT,-a ·,1 1 .617 _: [ 61 __;c 2.011 --~c. 2,367 -J L .=-2,466 2.070 -: [ 51 _ ;C-2,211 ~~]L 2,534 =-j [:: -2,639 2.270 ~L -51 ~-~[ 2,431 -=ic 2.778 ~c 2,894 1.274 61 1,632 1,865 1,943 1.844 61 2,362 2,700 2,812 1-1/2 I ........ , ..... w ...... ~.,. . -. 2.090 61 2,677 3,060 3,187 '"~•1•p,A 1.967 61 2,520 2,880 3,000 2.S47 44 2,353 2.690 2.802 2.720 44 2,513 2,872 2,992 1.604 ~r-37 --;r-1,246 =--ic ,.424 _ 7 r-1,484 2.330 _Jr____ 37 _ -i I 1,810 -1r~ 2,069_--]I_-2,155 . -it--:· _ _1 [ . -. ]1 _-_--. _-ii--2 I ""'"''' ..... "" ..... ,v I 2.640 -I -37 2,051 _ _2,3-!'1. 2,442 ,.,...,...., ...... r--2.617 :-:-J L --= _ 31 : ][ _2,033 -1r -~;32~· . -JI 2.~1 3.308 I l ----30 . 7[ 2,084 ll -2)82_ -Jr -2,481 I 4. --· ·--_--... ~--I'-3.660 _JL 30 :__JL 2,306 _JL 2,635 __ JL 2,74S c®us LISTED I 2-, 12 EDDY.no~ I 2.809 1,770 2,022 2,107 scHEOutiSo I 3.S30 30 2,224 2,542 2,648 <§> SCHEDULE_.icV I S.800 3,654 4,176 4,350 I EDDY FLOW-. n--3.361 JI ll , ... , -11 1,533 r--1,596 APIWt'ED 3 scHeDuLE 10 -1 r 4.340 19 1,979_ I_ 2,062 SCHEDULE 40~ IL 7.580 _ 1,132 JI 3,456 L 3,601 L 3,024 JL Ci] ._, !!~ I EDDY FLOwi I 4.968 1,982 2,265 2,360 .. SCHEDULE 10 _ I 5.620 19 2,242 2,563 2,670 NFPA. -=c=-SCHEDULE 40• I 10.800 4,309 4,925 5,130 6 SCHEDULE 10 IC 9.289 lC 10 :7l 1,951 =_JC 2,229 ~c 2,322 • SCHEDULE 10 ] 16.940 7 2,490 2,846 2,96S 10 • Only AVliWllt In Casa Grnlt. Al.. BULL MOOSE TUBE .. ~ I ENGINEERED SPRINKLER PIPE SWAY BRACE CHARTS 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED <f9 Ci] NFPA" APPIMD ---o~• ................ --~ .....,,_,. Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or CompreHlon/Grooved Coupllnga Max Zone of Influence Load (FpwJ lbs. Max. Transverse and 4-way Brace Spacing ( ft.) ••• According to Pipe Transverse Brace Spacing• HLF for the 2006 & 2009 IBC ( ASCE 7-05) & Cp for NFPA-13 shown in BOLD TYPE Size 20 ft 25 ft. 30 ft 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 :Z.75 3.00 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1 1/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1012 867 726 40 40 40 40 40 37 34 32 30 29 28 26 Bull MooH Tube EDDYTHREAD 40 st .. , Pipe Joined by Threading, Bonding or CompreHlon/Grooved Coupling• Max Zone of Influence Load (F/lll'J lbs. Max. Transverse and 4-way Brace Spacing ( ft.) ... According to Pipe Transverse Brace Spacing• HLF for the 2006 & 2009 IBC ( ASCE 7-05) & Cp for NFPA-13 shown In BOLD Size 20 ft. 25 ft. 30 ft. 1 119 95 11/4 218 175 1 112 312 250 2 518 414 ~e D ~MDIIDaanala~ 78 143 205 339 TYPE 35 ft 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 67 56 40 40 36 31 28 25 24 123 103 40 40 40 35 31 28 26 175 147 40 40 40 37 33 30 28 291 243 40 40 40 40 36 33 30 For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Claitson Road Chesterfleld. MO 63017 Gerald. MO Kent.WA Casa Grande, AZ 2.00 2.25 2.50 2.75 22 21 20 19 25 23 22 21 26 25 23 22 29 27 26 24 www.bullmoosetube.com salesObullmoosetube.com 3.00 18 20 21 23 Dallas, TX Masury.OH 11 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N V1ctauhc Mechanical-T9 Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole Is cut oversize to receive a "holefinder• locating collar which secures the outlet In posItIon permanently. A pressure responsive gasket seals on the pipe 0.0. Cross-type connections can be achieved by ut1l1Z1ng two upper housings of the same style and size, with the same or differing branch sI2e connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieYe a cross connection. Style 920 and Style 920N Mechamcal-T outlets are available with grooved or female threaded O<Jtlet Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available. supplied with plated bolts All sizes of Style 920 and 920N are rated at 500ps1/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on h,gh denSJty polyethylene or poly- butylene (HOPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true go• angle when permanently attached to the pipeline surface. Addrt10nat/. the V1e-Tap 1ra hole cutting tool, wh1Ch alows for hole cutting capab ~ties on pressunzed systems utit,zes the Style 920 Mechan,cal-T In coniunct,on with the Series 726 V,c-Ban Valve to create the Style 931 Vic-Tap II Mechamcal-T unit. See page 8 for further 1nformat1on. STYLES 920 AND 920H STYLE 920 CIIOSS PATENTED MATERIAL SPECIFICATIONS Housingltoating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coaling. Ductile iron conforming to ASTM A-395, grade 65-45-15. Is available upon special request. • Optional: Hot dipped galvanized Gasket: (Specify choice*) JOB/OWNER System No. _________ _ location ___________ _ www.victaulic.com • Grade "E" EPDM EPDM (Green color code) Temperature range -30°F to +230°F/-34°C to +ll0°C Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, 01I-free air and many chemical services. UL ClasSJfied In accordance with ANSI/NSF 61 tor cold +86°F/..-30°C and hot +180°F/+82°C NOT RECOMMENDED FOR PETROLEUM SERVICES • Grade "T" nitrile N1tnle (Orange color code) Temperature range -20°F to +l80°F -29°C to +82'C. Recommended for petroleum products, air with 011 vapors, vegetable and mineral oils within the spec1f1ed temperature range. Not recommended for hot water serv ces over +l50°F/+66°C or for hot dry air over + 140°F/+60°C. *Services bsted are General Service Recommendat10ns only. It should be noted that there are sennces tor which these gaskets are not recommended. Reference should always be made to the latest V1ctaullc Gasket Select on Guide for spec1f1c gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel trackhead meehng the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183 CONTRACTOR ENGINEER Submftted By ________ _ Spec Sect ____ _ Para ____ _ Dale ____________ _ Approved __________ _ Date _____________ _ VICfAIJLr IS;, RlGl5r[RLD 'RAOU,<AA~ Of ,ICIA'JL~ t;OMPANY O 2011 VICUULJ". CO>.tPAN, ALL pr,,us RtSUl'/Ul. REV_ i ~t.aulic' --02_1 CARBOl-4 STEEL PIPE • HOLE CUT PRODUCTS Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMAU THREADED O\ITlET • Provides a direct branch connection at any location where a hole can be cut In the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechantcal-T cross assemblies • Pressure rated up to 500psi/3450kPa on steel pipe; also available for use with HOPE pipe • Sizes from 2 x ½"/50 x 15mm through 8 x 4"/200 x 100mm IMPORTANT NOTES: ,, ,'r ,_•Ill-'> I ,t.......i,~ '20 laclin .. -920H 2 X 1J (a)a nv" <o 15 >, (a) D 92)~ 20 Ql)~ l¼(al to 9::J'~ 32 I Y, (a) ta 40 9~0>1 212 " 4,0'1 65 \4 (a)~• 9,0'J 10 1 CoH> 92m, 25 'i"tt'<a)u 9201, 32 I II, t '•) 0 9;01, 40 7~., ,. 1> la) 9i0t, IS 921)'1 l(a., 9L0~ 25 I '{,}) o 9>0~ 32 1 'I (a) 0 910~ 4) 3 " 1,J {a) D 92,)" 60 15 !<. la) o 92 ~ }O I (.)' 9);)'-1 ;s ':4 ca, ta 92u, 32 lb) 920',j 2 (a1" 920'4 so 3•, X } 9JtJ" YO so ... JI "' ..,,,.,, I pol .P• 500 3.,50 ,OU 3A)U 00 3•'0 ')0 l4'J c;;ryo w,o 5,0 w;o $00 J45J soc 3450 <01 3450 \J( 3450 l.O 2065 300 20<:S j()o 20 S sco 3451 500 3410 ,Oo 34',U ,oo l•SO ,Oo 14',( 500 34>0 ',()() ¼,C 500 (450 s~o !45J I ~M ~ l •• llt>d>H .000 -I SO 2.10 JS I 'I I :,0 1.91 38 50 I SO e, 38 41 I 7, 2US 44~ "2 1 <; 2 0' 44 'i '2 I SU ~LI lo SI> I Sll 218 38 55 . so 106 381 s, 75 230 H )< 20Cl 2,8 508 Sil , l 22 .. Ja 56 I SO l 19 38. 56 I ,O 2.0 38 s, I "S 2 30 445 58 2.00 '28 5J8 ,g 1)0 l ',l 381 (,4 ',o .t.t!Y '8 6J 1,0 na 18 6 I 1, ; ')~ 44 5 6, 2 '0 ~ 8 ;,s 2 '.,() 2/5 63> IQ 2 so ](YJ 03 5 76 'HI '1/JIL "3d,oo -2.,3 .. l '3 ~4 l ol €• 27, 70 : ' 70 : 4 10 774 10 274 7J 300 lb HlO 76 rs 7J '•5 7 2 5 70 30:.) '6 300 76 3.0, 78 ;os 78 3.06 le 3 2, 83 ,so 8~ 3,0 89 ll ,., . r.,-,. lndoel - l.00 0 1 ·2 ]Q l J >l4 33 84 l 56 90 l So 90 1S6 90 3 5 Y5 TABLE CONTINUED ON PG. 3 1W y ........ ltoeo ,,_ -1 ~I 5 15 4 136 161 l, 4 ljo 161 ,h 41 136 161 us " 1;ti 16' S '5 41 136 8] 64 14' I 81 5,,. •c 11~ ) "' S~4 46 143 182 ,. 29 ~ 1(,(1 1 82 !J 2t> 4G 15,, 25 c46 57 64 225 64Q s· 16': ns 16 57 lf4 • O] b . u 49 IOI. 1.Y, u29 49 60 1 co ,8 1r,o L ,.,.6 6 ,, Se l:,o .,:,..::8 ~ I' ,,, 156 ~ 28 • I'- 58 bo :.28 . ]', 58 I ,o 2.78 b 75 58 'TL 44 6J2 ~, , .. 11 .02 ~ .. ,.--·' l Tu,. Cn, 1f-1 IKl,n I Un, ,LbJ, -I ;f, t,t 2 7,:: 7() 2 C 70 J ,, n lOO lb 3 ., SJ 215 /0 '75 '0 275 ·o '00 /1, I LS 83 318 8 318 81 3.18 SI JOO -6 315 Sl ,I, ' 10 C 5 ro . ,, /J ,uo '6 3 25 Sl l 88 gQ 3 83 ~ .. 31 1' l 1 15 ,o 14 l, 17 lo " lO 14 IQ ' 4 }9 4 1' I H, ,· 30 lo 3.9 0 ,g I/ 35 ltS 35 '6 3.4 16 l4 16 ; ' 16 l8 '.8 ·11 0 IQ 2' l2 15 31 1$ 32 • 5 3., < l 1P. 38 I • 41, l I ,8 18 Style 920 and Style 920N 'lous,ngs cannot be rnated ro one d'IOtber to ach,e~e cross connections "lem,,, of run to eng,ig,·d p,p., end ferndlt> thredded outlt>t onlt (d,men>1om dppro~1rnote) r Available w,th grooved or female threaded outlet. Specif> cho,ce on order www.vic:taulic.c:om t Cent• r of run to enc.I of fim'lg # Female threaded outlets are available to NPT and BSPT soec,f,cauons ~ '>e0 r,19e 7 for Fire Prott>et1on JJJprovah and prt',sure rdt1ngs. (a) 811t1sl ',tanda•d fer'ldl pi~ thredced , Hlet is ava1labk· d, I st!'d Sp('ofy 8'PT clearlv on order (b)For 76.1 mm trreaded Ol-tlet specify n,· BSPf clearly O'I order. § 'Ids appro.ed for fire protect on ser"ces " _P( B approved for fin protection se•v,r.t s :: Approved for use in Ch1N by I ,anj,n Appro,als Compary '/J" ,Alo · IS A RLGISTERl:.0 H>ADWARK Of VJ"IA JU:-CC~PANY C 201/ ;r.rA U:: C0MP~N'I AL. RIGH JS HLSLRV£D 11.()2_2 CAReoN STEEL PIPE • HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS ,, ti "'. '. A;:,"• ,. F ~ . .. Ill . •'I.,.' ft• "18rEd> I I 1,-vu "' l 1~ ~~=,. ,;o ~ I" TM fi<L '1! 'Y 1(,,,, 1111<!-• !';. .... , ~ ..,. .... .... '~ IMllu Lit,. Ll>t, """ noiw ~ ------~. II TAIILE CONTINUED FROM PAGE 2 4 , (.l a 920N soo j 0' J"" 'Ol 27' J v 100 IS 34 l 3o 9 8 0 (l 18 ••(;;/a Y,ON 510 '0 lf)I) JS6 }.bQ 701 us j 7 t 20 145) lo 6 90 18 78 10 18 V, 11.,, 0 \JO J~ ) 88 l 'o zou 01 1.15 3o 2< 9;0,1 >45 J lo 7 l 9 '8 /8 70 18 GROOVED OUTLET .. (;;).,, 9,0t, •oo 308 l 7o 400 Jo9 701 l.00 40 16 32 (bJ 14~0 44 .... 18 9,-11)2 68 '78 I~ I~ '.8 czo~ 500 2(} 1.2e 400 ·100 269 /\)' ~ 2c: 42 39 3451 so,; 83 101 I0~ 08 78 El .o •c y z <.o q;o~. ,oo 250 ; 2, 400 4 00 2 6') /01 •.88 4o I 3.!r.;) 61.S 8l 10. 10. 6d le ~'I l3 V O]O S'lC L < 2 R~ 100 100 l >fl ,.1 4.63 ~" ~o 34$0 6llll ".l 102 10. 6a 186 I'd ,i> 23 ' 5JO • J 289 -100 1~' "34 4o3 6~ t 751mrnl 920 w 34SO 69~ '3 10, ~8 1~6 118 2Y l~/ I 9.-.\..1 !:-.,t) 3 50 J Jl 4 5 4 '2 }_6l "73 '. 12 ~4 u4 ,45·1 38 I i4 114 JS 8 % El l.8 )'J FEMALE THREADED OUTLn l08 3 7o lo' /64 lQ~ <.) 10'! 0 I '(Jo 9,QN '00 ~ X ---2U 34 ) 445 78 % 114 ·g 13 I\, C.,·1> 0'0N <.>o ]00 '.12 400 16' 764 J jS • Provides a direct branch connection at 40 J4<'J sua Sl 102 194 ,, 13 any location where a hole can be cut j ,., 920t. ,o • '>G 'JS 40() H,' 764 4 ·o 40 in the pipe ~ 34'U 63 < 8; 10: 6 194 ~l 19 /'f lmml ~~ ,(_)) 2 ' 2 ·~ 100 400 2 ,-,1 7"4 ·129 80 '8 • A pressure responsive gasket provides 3450 o9<J l 10; IC. 0 194 ,:, 1? b the seal 3 (a) 920 <oJ l ,o lll 4 S·1 • so .! -:,l /bl 4 88 68 •5 80 34',() ijo9 d-1 11-: I 4 6 I /4 24 J.1 ,o • Request Publication 11.03 for s I Y, (.a) t ~20 <t> ) 0) 403 475 4 ,s 1.1n 9. 0 , cf., ,_,. lo Mecharncal-T cross assemblies 125 )( 40 1450 ',() 8 102 12 17' 80 210 9,1 l I H l(a,t 9,0 <Ci) 250 ◄O) I 5 •I 15 '16 Q 0 .; 18 81 8) • Pressure rated up to 5OOps1/345OkPa so l4SJ ~J s IOl 121 1}1 80 1·16 II 37 .l6 on steel pipe; also available for use l½ fa) t 9,0 ,oc rs 3 63 4 '5 ~ 7$ 3 lo 9"0 41:;3 81 '9 with HOPE pipe ~ 345) &;O ~. 11 12' 80 "'46 118 38 36 ,00 2 75 3 ""S 4,..,.~ 3 JI\ 9·0 45) 8.0 • Sizes from 2 x W/50 x 15mm It.I rrm 11 920 3.1<0 699 9 12 ~o '46 118 36 through 8 x 4'/200 x 100mm 3 I.,) t JO ; 0 381 00 l6' 3.1 Q 0 C )I 8• .. 920 ,G eo 14'0 SP 91 12 18 80 ]46 135 ,.a 4) IHO x 9l0'1 <'O ',o j ' 4 ,!) 3 ? 80) ,.88 80 34'v 6" 9, 14 e1 2Gl 09 36 9:0 ,:,o ;so 381 ,oo lOO 946 >31 ~o l4SO ~89 9, Ii '6 240 q5 lb TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: •• Cerce• ot run to engaced pipe end female chreaded outlet only (d,men51ons appro•imalP Style 920 and SC) le 920M housings ca'lnot be Avail.lb!, w,ch grooved or f<crn.ik> thr£ .ided outl;>r Sp••c,fy ro1ce on orr:l.-1 matt>d ro one another I Cer-cer ol run to end of fitting. to ach,e-,e cross co-inect,ons , Fcmdl • chri>aded ourkc, arP .ivailabk· co \lPT dnd 3Sl'T s~ ,f,cariom. 1P See page 7 for, re Protection appro•.,als and pressure ratings. (al Bri11sh Standard female p pe cl'-readed o .. 11e1 ,s a·,a1lable as I seed Specify 't1S:>1 clearly on order (bJro, /61 mm threadt>d outk>t, pec1fy 21 ,· BSPT de<1rly on orckr ~ Vd, opprovt'Cl for firp µ1otec. t,on ser '" E'S a l PCB approved for tire protection services ;, App"Jved (or u ,e II C nInJ by T d'1JII Ac.prov,ih Cornpan\ www.victaulic:.com W' l~iJLr IS A RlGl>J(RlD RAOlMAIW Of vC [l,'JLJ; GO'APANV C 201/ '11:IAvLr. COMPANY. All Rr.H IS R£5lR'llO REVJ4 ~ctaulic:! .J 02_3 CARBOh STEEL PIP£ HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS "',t 'Jl,1,., p ... ,, I), ~ ... , ' "'"1,"!' 1Run ~ 16,.IIDCf:I I I rar YU ., , ~lfl ~-5tu ?,O 1 .. J!!<I, w, .. w 'I lnd!tt "' pol ..... .... .... ~ t,,d,ft _, noo ,P1 ., -----TABLE CONTINUED FltOII PAGE 3 397 >< 11,t n.N ;oo '00 , /8 .150 3'0 8 ,,; lJ 0 V 40 3-lSO SOI! % 1 ~4 219 8, ;] l 2 t JlON sou 15) 3 75 4 SO 3 !O €23 lo~ 90 t so l450 {:.) > 9' 1 4 34 }'Jq 'l'l 4' IV 6 I• .l) ,()() 11, <43 S.13 S 13 l 9 91) l JS ' 150 " l2 (0) no1-. ,450 44 < 12 30 lO 9t> :')2 83 B GROOY[D OUTUT '00 :oo 44.J 5.13 'ii' , Q t: 15 J 25 S4 92 N ;~so >, F 11 • JO • JO 96 :::1.2 ~3 2.4 2 (al to 92cN ,oo 2.'D 4 JS 513 ,n , -9 9.IS 188 6." so 34,0 ol 5 11' '30 '10 % 232 )9 r 21, 9]J ,00 275 4.01 SP 5 1. ; ,,g 0.51 •ll>l •!, I 65 3450 ~9.~ 1'0 130 JO 9~ i6, 18 38 \ /6lenrri0 ~JO 500 275 .i I~ S 21 36'! 10.~1 463 T 345() 69) ,~ lol ')4 ,67 18 t 3(.; t 920 500 J so 'll 550 S '3 369 1051 5 JI 99 \\ 80 34SO 88.\1 10 ·•o JO 94 )67 . ;, 4, 4 (3 to 9L) ',00 450 331 s J ~JO ,69 IC. S 2S 10 100 34',0 114 3 1• 46 I' 94 ,c,, I J 46 FEMALE THREADED OUTLET l''i(a soo 2 0 441 o l ,6l 94) 3 }5 /3 1~90 x •O 9'?'1 J4,0 'JS 11 30 92 139 a~ ,, 2 (d' 92!)'1 ,co 2 )0 4 Ja , 1 ,63 9·'-1 !88 BJ • Provides a direct branch connection al so :4~0 63.S 11 130 QO ]lU 99 l6 any location where a hole can be cut 6.1mm 9:J ,00 27, 4 33 <s, S 3 l 61 Qto 4 63 9' ,n the pipe 14 0 699 11 1~0 no q: 23° 118 43 3 Q:O 500 3 so 41' '<~ S'l lol 940 5 ;1 8, • A pressure responsive gasket provides 80 '4 0 889 11() 140 l,U 02 39 h l7 the seal 1oe.0mm ...,;o '00 4 ,o 445 , lS l t,l o•o b '2 J•SO 1·.13 113 137 "2 ,>) 55 • Request Pubhcat1on 11.03 tor 4 o,o 5X 450 )di S '5 )o3 94J c-25 1eo Mechanical-T cross assemblies 100 !4SQ 114 J %SO 1'6 ,n l " 159 8] TABU CONTINUED ON PG. 5 • Pressure rated up to 500psi/345OkPa •• Center of run to engaged p,pe end female threaded outlet onl, (d1men;,ons appro<imate). on steel pipe; also available for use with HDPE pipe t Avd11dble with grooved or femal-' thredded outlt>t <;pecify choire on orrJt•• Center of run to end of fim'lg • Sizes from 2 x ½'/50 x 15mm F0 mdlt> thrCd<led outl'ts are ctVd Llble to NPT dnd BSPTso ·c1f1c-n,ons through 8 x 4'/200 x 100mm ~ See page 7 for Fire Protection approvals and pressure ratings. (J) Brmst StandJ•d fer1ak p1p1:: threaded OJtk t is available a, listed Spec,fi (b)For lo.I mm th•eaded outlet, spl'c1fy 2/," BSPT cl~arly O'l order ~ Vds approved for fire protect on services a PCB apprO\led for foe protection ,e,v,ccs IMPORTANT NOTES: ,' ApprO\led for use 1n (.h,l"a by l1an11n /lpprovals Compal"y :,t) le 920 and Style 920N "lous,nqs cannot be mated to one Jriott'er ro ach,ese cross connect,ons. www.victaulic.com VJ"TAULr IS A RLr.lSrERrn fl>,1,0tf.<AH~ Of VICTALILIC CC~PANY. C 201 I ·1r.!At<UC COMPA"f/ ..... KICHTS RlS[RVlD 1102_4 BSPr cleJrly on ord1.:r "''· I.ti$, >z 4.8 n s 21 t 25 '6 H 84 38 84 !8 11 ·~ q,; 43 140 o4 0 45 CARSO • STEEL PIPE • HOLE CUT PRODUCTS Mechanical -T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOV£D OUTlET FEMALE THREAD£D DUTlET • Provides a direct branch connection at any location where a hole can be cut tn the pipe l!.-i , Brooch I 1v....-:., ... lncbn ,mm 16, " 25 1¼:, 32 )V1\a) t~ 40 2lolt 50 lb.I mn, H,,)tl' 80 4 ta) ta '00 8 " 2 "111 200 so 1'.? .a) t 65 761mm::, J (a) ta 80 ◄ (altc 100 ,1 ... \f.tt ""· ,. p ... , ", .. .,:i I 920 .. Poi ~20N ii.P.a o,o'II S lO 14'() ',.()'I/ ', )I) 34 1 9,0'1/ '·JO l4',) 920'1 ',U ,.,) 9:0 ',:)() 34'' 9..:0 ',OQ 34cJ Q}O 5()() 34~0 910 SJO 3450 'l}J 9./0 34,0 910 '0(J ,450 910 :,oo 3450 920 SO) 14:,0 ,Cf~ vs • •• T .. "4, """ WU .... .... .... .,,. ---TAIL[ CONTINUED FROM PAGE 4 3 e~ 1 ,•) .l8 99 II 14, ' 3 -l-1 I 1 IJ( l <>) 441 ' l ' 3 so~ I ] 1,0 ll0 2 'JO 4 38 '> l '> l ol' I I no 130 21, 40' '> l ., 2 090 110 IJO 1] 3 ,O 4' 'so >13 8d~ 110 HO '3, 150 ; SI '75 5 38 ' 4 3 97 14~ 137 r~ 5~4 6'9 6 25 i>'J'• U8 •:;,_ '59 ., 507 o'9 6 Q 0'-14 IN IJ I. < "j .( j 6 25 o'H H oQ 3.< !:! ii h.50 t,SQ 889 '3.., ·,;~ '6, 4' 4o 0 ' ,8 '14' i:z 1 ·o. 11.02 .\,'<" "~ .•• i .,, ' l ,~, G,v, 1fl' '( .,,.. ........ -u... Lb\; -, ... -.,, . - 19 lH 2/5 80 '1(~. J37 70 3.6 l 79 ~34 3, 5 ~4 96 l'7 83 '8 319 Q l4 lL> H 54 96 ]'1 83 l.8 ;• l 19 C )4 J sa 85 '>.0 96 2'/ 99 H 1 o' 10 5' ., ?3 80 7.6 02 2o7 1'8 39 34 1 o' 10 5 :, ,I 'O: f4 "2 167 1< -16 38 It•' Ill'.; 62:i 10S o4 9] J/.17 159 48 38 48 1]42 450 16 l'b 1/2 ,15 1'4 53 ~.3 4 8 12 42 450 116 110 J2 ,16 14 s.; 481 I 4} 456 I o 2. ,16 0 ' 48 1 •. 4] > l 1.26 I ; 2: 316 13' ~.3 H' 141 o:> •s' ,: .... 2: llr S9 ~.9 > I • A pressure responsive gasket provides the seal • • Certe• of run to engaged p,Pf' end, f Pmale threaded outl0 t ontv Cdimens,ons approximat<"' • Request Publication 11.03 for Mechanical-T cross assemblies t A·,a,IJble with grooved or female threaded outlet Specify cro,ce on order. ~ ( ertt'' of run to end of fitting ~ Female threaded outlets are Jva,lable to ~Pl and 3SPf spec,ficat,ons a) \ee pdgr• for Fr" Protl'ction dpprovdls ,ind pressurt' ratlrg, • Pressure rated up to 500pst/3450kPa on steel pipe; also available for use with HOPE pipe (al Briti;h Stdndard fernak? p pe trreadeJ ot.tlet 1s available as ~sted Specify "BS"T' cl.::ar~ on order. • Sizes from 2 x ½"/50 x 15mm through 8 x 4·1200 x 100mm IMPORTANT NOTES: Style 920 and ~t~le 92ON housings cannot be ma11>J to each otherto ach1e·1e cross connections www.victaulic.com (b)Fo, 76 I mm th1eaded outlet, ,peufv 7' ,· BSPT deady on O1de1 !I Vds approved for fire proteuion ser · Iles o LPCB approved for fire protcc uon services 0 App•o•,,-d for use ,n C ~ina by Tian11r Aop,O\iab Compan1 VICIAIJLII' IS AR GIST(PLO ,RAO(MAPK Of VICIA ,II<: C0MPAN( 0 :1111 VICJAIJLr. COMPANY AU. RIGII S RlSUl'/lO. RH_N ~ctaulic:! CARBON STEEL PIPE · HOLf CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechan1cal-T fittings can best be expressed in terms of the pressure d:fference across the nlet and branch. The pressure difference can be obta ned from the relationship below. @ Cy and Kv Values I Values for flow of water at +60°F/+16°C are shown 1n the table below. Fonnulas for Cy iK. Values: Where: Q = Flow (GPM) tiP = Pressure Drop (psi) C, = Flow Coefficient l,,qgerJCed tor cta11ty ,1 3 Ii, l(M ~--w ,6, 1 ' 315 ) . 25 Jl7 'A 16W l2 421 5 ' 1 I? 1900 40 9~' } 2,05 so l3 ~ 2½ lBh bS 730 ,o 7t>.1 "'"' , .;(}(.I ,,,· le I 3 JSOO oO <>i_<9 14 4 7 "50J 100 114 3 ,o I H.uer-WiU ams coeff,c ent of friction ,s 120. • P,rt: with a wan th1(kne5s of O 165,n /4 2mm •• 1 • Firel 0< k'" lnnovat ve Groove System (IGS) outlet www.victaulic.com ,r 1AULJI" IS A RlGISTf.REO TPAOEMARK O VIC'. A<ILIC CGMPANY. C 2017 •tr TAIJL1C COMPANY ALL HIGH'S PlSf.RVUJ 1102_6 4 0 6 10 , 1, ' IS •, ;, 6P = Q1 K.,,' Q = K. x _Ji,p so I].) 53 4> t • I} ''6 I) 10. Joi ''S }49 2 l 4 421 ;6C8 Where: Q = Flow (m1/hr) 6P = Pressure Drop (Bar) K.,, = Flow Coefficient )4 In l.7 JI IS ·IS 4 I Sl IS I 104 S91 ;o · 28.S :31 1031 401 3~36 ~ct.aulid in:,_ CAR!iOH STEEL PIPE HOLE CUT PROOUCTS Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS 11.02 The 1nformat,on provided below ts oased on the latest I sting and approval data at the t,me of publ1cat1on. Listings/Approvals a,e subJect to change and/or add1t1ons by the approvals agencies. Contact v,ctauhc for performance on other p,pe and the latest listings and approvals . .:, I ' • I !,, ' " ' , ' '-• f 1 • ),.' J' ,/w r ~ • I , ~ t ~~ ,_:_ I ,_ I ~ I UL ~ ,~ L'CI ~ 11/l -6 ).81' -66.5 Al ·o.40 IL'() •100 400 290 .3, !~ 65 -150 73.0-108; r 0s )JC) 27'5 1./'19 599 .·1% 11/2 -4 1875-4',0'J ~I Jf 100 30~ lO) )90 lll >f, 6<-100 30 -141 206) WoS 2065 1m 1590 ;496 21/2 • • U/5-4 500 Al 300 lOJ 301 :90 :;2 ,ti2 bS -100 7,0-1141 20o5 20o) 2005 19')9 59Q ~40t> ~ 0025 l 4 10 JOO 10, 2>0 :"0 :;z lt,2 1~s • 70b5 2065 Jl]J 19\l~ '599 .. 1<,t) ~c,lS 3,4 l0,40 lOJ ,o J JOO .90 .d~ l6, 0 lt8 > 2C65 }0o5 }065 11Jq(, 599 t·l'-16 8 862, 2'/2 10 40 4.0 •45 2'JO I 2'91 rss 1000 8 8.6)5 3.4 10 JOO .so •4~ 100 1 9 I 2C',:, 17l4 1000 8 P.o15 l~ ~o 40 JOO JO) ,!) 200 [91 /065 )OoS 1001 NOTE:S. 10 refers to L1;ted/Appro"ed Schedule 10 ,red spnnklt!r pipe 40 refers to Listed/Approved Schedule 40 Sl"el sprinkler pipe Dr refo>r, to L, ,ted/Approved Dyno-Flow steel spnn,lt'r piP<' n1dnufacturl'd by Arm r,(d11 TuhP Compdnv Sr refers to 1sted/Appro"ed Super-Ho steel spr,nkler pipe manufactured b'I All ed lube and (o'ldu11 Co·pora11on. VIC-TAP It HOLE cumNG TOOL FOR 4 -8"/100 -200MM CARBON STEEL PIPE www.victaulic.com The Vic-Tap II hole cutting tool 1s designed for use with the Style 931 Vic-Tap II Mecharncal-T urnt, which is a combination of the Style 920 Mecharncal-T and Senes 726 Vte-BaU Valve The Vic-Tap II 1s capable of tapping into carbon steel pipe systems under pressures up to 500pst/3450kPa. The Style 931 VIC-Tap II Mechamcal-T unit IS a full port bal valve whlCh can be mounted on 4'/IOOmm, 5'/125mm, 6'/150mm and 8°/200 mm diameter pipe. The Style 931 comes with a 2 ½0/65mm grooved outlet. The drtU motor 1s an electric motor with ground fault c1rcu1t interrupter (GFCI) in accordance with safety codes. For more 1nformatton. refer to pubhcat1on 24.01. VICIA1JLr IS A R[CMlHHJ RAOtMAR~ Of ~J:IA IUC MM~ANV C 201/ VICfAI u·:: COMPANY. AU. Pt':ftlS R[S[R'/lD REV_H ~taulic' 1. 02_7 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION WARRANTY NOTE Reference should always te made to the 1-100 Vtetauhc Field lnstallaton Handbook for the product you are 1nstall1ng. Handbooks are included with each shipment of V1ctauhc products for complete installation and assembly data, and are available in PDF format on our website at www.v1ctauhc.com. Refer to the Warranty section of the current Price List or contact V1ctauhc for details. This product shall be manufactured by V1ctauhc or to V1ctauhc specifications All products to be installed 1n accordance with current V1ctaulic installation/assembly instructions. V1ctauhc reserves lhe right to change product spec1f1cat1ons, designs and standard equipment without notice and without incurring obhgat,ons. For complete contact information, v1s1t www v1ctaul c.com ~ctaulic' 11.02 1480 REY N UPOATED 12/2017 '/ICTAUIIC IS A Rf(,ISTFRFD TPMFMAR~ OF ~ICTAU I(. COMPANY O :>01-'/k:.TAUI IC WMPAN'I Al RIGHTS RFSfRVfO l 02 Firelock® Outlet-T STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, ¾, and l '/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1 ¼ through 76.1 mm/32 to 76. l mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300psi/2068kPa and VdS rated up to 16bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes: Contact Victaulic for other optional coatings. •consult Section 10.01 for specific listings/approvals. SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS I Ill ~ MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. JOB/OWNER System No. _________ _ Location ___________ _ www.victaulic.com Gasket: • Grade "E" EPDM -Type A {Violet color code). Firelock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry {oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel {North America, Latin America, Asia Pacific) • Red enamel {Europe) CONTRACTOR ENGINEER Submitted By ________ _ Spec Sect _____ Para ___ _ Date ____________ _ Approved __________ _ Date ____________ _ VICTAULIC IS A REGISTERED TRADEMARK OF VICTAUUC COMPANY. C 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. q[/ G ~taulic' 10 S2_i IPS CARBON STEEL PIPE • HOL£ CUT PRODUCTS 10.52 Firelock® Outlet-T STYLE 922 DIMENSIONS NonHn,,I S11e I Hole I I Apprn, _ _ mch('<,/mm D~,1mete~-__ D nl('ll~1on<, -rn,h_:_., r~tll~mf:ll'r<, WC'1p,hl Lich [ P-T 8,.,... .-OQ~W,.S I Plt 41.J>OIJJA t• •1 tf ! Z W<.a 1¼ X ½ 11/16 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 ¾ P/i6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.S 46.5 27.9 98.3 65.0 0.50 l 1½, 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 l½ X ½ 1½, 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 ¾ 1½, 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 l 1½, 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 584 31.0 103.6 650 0.59 2 X ½ l 1/i6 1.66 2.19 1.46 4.60 2.56 1.3 so 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 ¾ l ½6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 11/t(i 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2Y, X ½ 1½, 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.S 62.0 43.4 137.2 65.0 0.73 ¾ I 1/i6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 l½, 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X ½ 11/ .. 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 650 0.73 ¾ 11/16 1.89 2.44 1.71 s so 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 l l/16 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). ------------------------------------------------ www,victaulic,com VICTAULIC IS A REGISTERED TRADEMARK Of VlCTAULIC COMPANY. C 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.S2 2 ~taulic' REY_G IPS ~ARBON STEEL PIPE -HOLE CUT PRODUCTS Firelock® Outlet-T STYLE 922 PERFORMANCE www.victaulic.com Ru11S11t JOuth!Sm 213 S,rt1on 161\C 120) FT I E.qup,.-ilt•nt lt·nKth ol I 1nrh SrhPduh -lO Sh I l P1rw (pt r UL [ -~ --~ .. ~ -~ I¼ X I 8.5 32 25 2.6 I½ X 1 8.5 40 25 J 2.6 2 X I 8.5 so 25 2.6 2½ X 1 8.5 65 25 2.6 I 8.5 76.1 mm X 25 2.6 • Hazen-Williams coefficient of friction is 120 VICTAULJC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2009 VICTAULJC COMPANY, ALL RIGHTS RESERVED. qfV G 10.52 ~taulic' 10.52_3 Firelock® Outlet-T STYLE 922 INSTALLATION WARRANTY NOTE Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com ~taulic· 10.52 3355 REV G UPDATED 12/2009 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2009 VICTAULIC COMPANY. All RIGHTS RESERVED. 10 ,2 Ductile Iron Threaded Fittings INTE R NATI O NAL Ductile Iron Threaded Fittings Specifications • <©> branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • Ductile iron castings conform to ASTM A536 • Fitting dimensions conform to ASME 816.3 • Bushings and plugs conform to ASME B16.14 • Fittings are 100% air tested • NPT threads on all fittings conform to ASME B1.20.1 c@us LISTED <G> APPROVED • Independent lab verification that fittings meet applicable chemical & physical properties • Manufacturing facilities are ISO 9001 :2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 Fig. 3SE 3 -90° Elbow c@us ~ LISTED Size Part Number A Pacldn Weight in in nn r ast r lb 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 175 25 50 0.8 1-1/2 35E 3014 1.94 18 36 11 2 35E 3020 2.25 10 20 1 8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 3SRE3 -90° Reducing Elbow Size Part Number A B Pacldna Weight in in in Inner Master lb 3/4 X 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 X 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 X 3/4 35RE3010006 1.38 1.45 so 100 0.4 1-1/4 X 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 1·1/4x1 35RE3012010 ,_ 1 58 . 1.67 30 60 07 1-1/2 X 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-l/2x3/4 35RE3014006 1.52 1 75 25 50 07 l-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 X 1-1/4 35RE3014012 1~ 1 88 -18 -1.82 ,_ 36 1 0 2 X 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 X 3/4 35RE3020006 1 60 1.97 18 36 1.0 2x1 35RE3020010 1.73 2.02 16 32 1.2 2x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 X 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 X 1-1/2 35RE3024014 2.16 251 6 12 2.2 2-1/2x2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 3SF 3 -45° Elbow Size Part Number A Packln Weight in in nner aster lb 1/2 35F 3004 0.88 150 300 0.2 3/4 35F3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 IA 1-1/4 35F 3012 129 25 so 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 3ST 3 -Tee Size Part Number A Packin Weight ffi } in in nner er lb 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 05 1 35T 3010 1.50 25 50 07 1-1/4 35T 3012 1.75 10 20 1 1 ~'p;-t 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2 4 2-1/2 35T 3024 2.70 4 8 43 111 S\IITH-COOPF.R l.\:TERNATlON,\I;' • TOLL FREE 1-800-706-()(>70 • F.\X (32J) 890--H5o • \\Ww.~mirln:oopcr.cum Fig. 35RT3 -Reducing Tee c@us ~ LISTED Size Part Number A B C Packina Weight In in in in inner Mattt•r lb 3/4 X 1/2 35RT3006004 1 20 1 20 1 22 60 120 0 4 1 X 1/2 35RT3010004 1 26 1 26 136 30 60 0.6 1 X 1/2 X 1 35RT3010004010 150 1 36 1 50 30 60 06 IX 3/4 35RT3010006 1 38 1 38 1 45 25 50 06 1 X 3/4 X 3/4 35RT3010006006 1.38 1.31 1 45 35 70 0.6 1 X 3/4 X 1 35RT3010006010 _, 50 .__ 1 45 1 50 25 50 0.7 1-1/4 X 1/2 35RT3012004 1 34 1.34 1.53 20 40 0.8 1 _ _!,-1/4 X 1/2 X 1-1/4 35RT3012004012 1 75 1 53 1 75 25 50 09 1-1/4 X 3/4 35RT3012006 ,_ 1.45 1.45 1 62 15 30 0.9 1-1/4 X 3/4 X 1-1 /4 ,_ 35RT3012006012 175 1 62 1 75 20 40 1.0 1-1/4 X 1 35RT3012010 1.58 1.58 ,_ 1 67 15 30 1 0 ,_ 1-1/4 )I 1 X 1/2 35RT3012010004 1 34 1.26 1 53 25 50 0.7 1-1/4 X 1 X 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0 8 1•1/4X 1 X 1 35RT3012010010 158 150 1 69 20 40 0.9 1-1/4 X 1 X 1-1/4 35RT3012010012 1.75 1 69 1.75 15 30 1 0 1-1/2 X 1/2 35RT3014004 1 41 1 41 1 66 16 32 1 0 1-1/2 X 1/2 X 1-1/4 35RT3014004012 1.81 1 56 1 88 24 48 1 1 ,_ 1-1/2 X 1/2 X 1-1/2 35RT3014004014 1.94 ...J...66 1 94 12 24 1 2 -1-1/2 X 3/4 35RT3014006 1.52 1.52 1 75 16 32 1.1 1-1/2 X 3/4 X 1-1/4 35RT3014006012 1 94 1 66 1 88 20 40 1 1 1-1/2 X 3/4 X 1-1/2 35RT3014006014 1 94 1.75 1.94 18 36 1 2 1-1/2x 1 35RT3014010 1 65 1 65 1 80 12 24 1 2 1-1/2 X 1 X 1/2 35RT3014010004 1.44 1 25 1 69 20 40 08 1-1/2 X 1 X 3/4 35RT3014010006 1.50 144 1 75 16 32 09 1-1/2 X 1 X 1 35RT3014010010 1.65 1.50 1 80 16 32 1.0 1-1/2 X 1 X 1-1/4 35RT3014010012 182 1 67 188 12 24 1 2 1-1/2x 1 X 1-1/2 35RT3014010014 1 94 1 80 1 94 12 24 1.3 1-1/2x 1-1/4 35RT3014012 1 82 1 82 1 88 12 24 1 4 1-1/2 X 1-1/4 X 1/2 35RT3014012004 1 41 1 34 1 66 16 32 0.9 1-1/2 X 1-1/4 X 3/4 35RT3014012006 1.52 1 45 1 75 16 -32 1 0 1-1/2 X 1-1/4 X 1 35RT3014012010 1.65 1 58 1 80 16 32 1 1 1-1/2 X 1-1/4 X 1-1/4 35RT3014012012 1 82 1 75 1 88 14 28 1.3 1-1/2X 1-1/4 X 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1 4 2 X 1/2 -35RT3020004 1 49 1 49 1 88 10 20 1 5 2 X 3/4 35RT3020006 1.60 1 60 1.97 10 20 1.6 ,_ --2x1 35RT3020010 1 73 1 73 2.02 8 16 1 7 2xlx2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 X 1-1/4 35RT3020012 1 90 1 90 210 8 16 1.9 -2 X 1-1/4 X 2 35RT3020012020 2.25 2.10 2.25 8 16 20 2x1-1/2 ~RT3020014 --202 202 2 16 8 16 2.1 2 X 1-1/2 X 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x 1-l/2x3/4 35RT3020014006 160 1.52 1 97 10 ,_ 20 ._ 1 4 2x 1·1/2 x 1 35RT3020014010 1.73 1 65 202 8 16 15 2x 1-1/2x 1-1/4 35RT3020014012 1 90 1 82 210 8 16 1 7 -2 x l-1/2x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1 8 Fif. 35BT3 -Ball Head Tee Size Part Number A B C Packlna Weight in in in in lnnar IMHler lb 3/4 X 1 35BT3006010 1 45 1.45 1.37 30 60 0.6 1 X 1-1/4 35BT3010012 1 67 1 67 15L -20 40 0.9 t---tlt-----t A B 1 X 1-1/2 35BT3010014 180 1.80 1 65 15 30 1.0 1·1/4 X 1 X 1-1/2 -35BT3012010014 1 88 1 80 1 82 15 30 _12 1-1/4 X 1-1/2 35813012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 35BT3012020 2.10 210 1 90 10 20 1 6 1-1/2 X 1-1/4 X 2 35BT3014012020 2.16 2.10 2.02 10 20 1 8 1-1/2x2 35813014020 2 16 2.16 202 8 16 1 8 S\IIT I I-COOPER INTER~K rlO"\AL • TOLL FREE 1-800-761>-0076 • FAX U.B) 890~56 • \1·ww.~mirhcoopcr.wm 112 c@us ~ Fif. 3SCP3 -Straight Cor,plint with Ribs LISTED Size Part Number A Packing Weight in in inner Master lb 1/2 35CP3004 1.38 200 400 0 1 3/4 35CP3006 163 100 200 0.2 --,-,--,~ 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 Ir 2.00 ,~ 35 70 -,--0.5 ,--,--1-1/2 35CP3014 2.19 25 50 0.7 35CP3020 ,--,-1 2 -2 2.62 15 30 2-1/2 35CP3024 3.00 9 18 2.2 Fit. 3SRC3 -Hex Redacint Cor,plinf Size Part Number A Packing Weight in in Inner Master lb 1 X 1/2 35RC3010004 1.69 80 160 0.3 1 X 3/4 35RC3010006 1.69 60 120 0.4 ,--,---1-1/4 X 3/4 35RC30 I 2006 2.06 40 80 0.6 2 x 1 {not hex) 35RC3020010 2.81 -20 ,-40 -,-1.0 Fig. 3SHB3 -Hex Bashtn, Size Part Number A Pacldna Weight in in Inner Master lb 1 X 1/2 35HB3010004 1.06 180 360 0.2 1 X 3/4 35HB3010006 1 06 180 360 01 ,--,--1-1/4 X 1 35HB3012010 1.19 90 180 0.2 °1-'112 X 1 35HB3014010 1.25 ,-75 -,--150 0.4 ,--,--1-1/2 X 1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 ,-40 -,~ 80 0.6 ~ ,--,--2x 1-1/4 35HB3020012 1.38 40 80 0.6 ,_ 2x 1-1/2 ,--35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head /'lag ize Part Number A Pacldn Weight in in nner aster lb ~A 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 06 Fif. 3SU 3 -Union with Brass Seat Size Part Number A Packina Weight in in Inner Master lb 1 35U 3010 2.19 20 40 1.0 _1-1/4 -35U3012 2.50 15 30 1.2 ----,--1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 -6 -,-12 2.4 113 S!\IITII-COOPER IN'TER:"\.\TIONAI/ • TOLL FREE 1-800-76M)076 • F\X (.~2.,)89<1-4456 • www.,mirhcoopcr.com 4tt I (»J,il.l.n"{ i'LUS I Ductile Iron Fittings -Class 300 UL/FM c@us~ Flf. 3SX 3 -Cross LISTED Size Part Number A Packing Weight in in inner Master lb 1 35X 3010 150 20 40 09 1-1/4 35X 3012 1.75 12 24 1 4 ,-,----,--1-1/2 35X 3014 1.94 8 16 1 8 2 35X 3020 ,-225 6 -12 2.8 Fif. 3SRX3 -Redacinf Cross Size Part Number A B Packlna Weight in in In Inner Master lb 1-1/4 X 1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2xt 35RX3014010 180 1 65 12 24 1.4 2x1 35RX3020010 2.02 1.73 8 16 2.0 Fif. 3SC 3 -Cap Size Part Number A Packing Weight in in inner Master lb 1/2 35C 3004 0 87 300 600 01 3/4 35C3006 097 200 400 0 1 -,--,~ -1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1 28 ,-70 -,-140 0.4 -,~ -,--,--1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 ,_ 25 -,-50 -,-08 -,-2-1/2 35C3024 1.70 18 36 1 6 Fif. 3SBC3 -Beam Clamp Size Part Number A Packing welgllt in in inner Master lb 3/8 35BC3003 0.75 100 200 0.3 1/2 35BC3004 r-0 75 80 160 05 S\IITII-COOPER INTER~K f'l0"1AL • TOLL FREE t-800-766-0070 • FAX U.B) 890~.in • www.!>mithcoopcr.com 114 INSTALLATION INSTRUCTIONS FOR WOOD & STEEL 1. Insert the appropriate nut driver into a l'B' or 1/2' portable drill. 2. Insert the SAMMY~ into the #14 {black) nut driver (pin 8113910). Drill should be in a vertical position. 3. Push the face of the nut driver tight to the member. Begin installation when the nut dliver spins freely on the SAMMYS. stop drill and remove. 4. The SAMMYS Is now ready to receive 1/4", l'B~ 112· or metric all thread rod, boh stock. (The 112' requires the #14SW red nut driver} Note: When installing DSTR, follow the above lnstn.H:tions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. . I , .HORIZONTAL, ,_ -----~---~--~ -- 1. Insert the appropriate nut dnver into a l'B' or 112· po,table driR. 2. lnserl the SAMMYS into the #14SW /red) nut driver (pin 8114910). With drill unit in a horizontal position and at a right angle to the struclura/ member, begin installation. 3. When the nut driver spins freely on the SAMMYS, stop the drill and remove. 4. The unit is now ready to recewe 114", l'B". M10, MB or metric all thread rod or bolt stock. Note: When installing SWOR, follow the above insl!IJclions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in put/in steel. INSTALLATION INSTRUCTIONS FOR CONCRETE INSTALLATION STEPS - 1. Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pnHirill the concrete member to a depth of 2· with a hammerhota,y hammer drill set on impact mode. 2. Alter pre-drilling has been completed, install the SLEEVE TOOL over the bit {the bit should remain in the drill), and insert the #14 (black) nut driver (pin 8113910) into the opposite end (see Vertical Installation note above). 3. Insert the CST screw into the nut driver. 4. Place tip of screw into the pre-drilled hole. tum impact/drill unit to drill mode and begin Insertion. When the nut driver spins freely on the CST screw. installation is complete. Stop and remove drill. 5. The concrete screw is ready to receive 114'. l/8", 1tr, or metric all thtead rod or bolt stock. (#14SW red nut driver used with 11r screw} Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so w/U destroy the pullout factor of the screw. 1. Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit. pnHJriH the concrete member to a depth of r with a hammer/ rotary hammer drill set on impact mode 2. After pre-drilling has been completed, install the SLEEVE TOOL O'lef the bit (the bit should remain in the drilQ, and insert the #14SW {red) nut driver (pin 8114910) into the opposite end. 3. Insert the SWC screw into the nut driver. 4. Place tip of screw into the pre-drilled hole, tum impact/drill unit to driH mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. 5. The SWC screw is ready to receive 114', 318" or metric alf thread rod Of bolt stoc/c. Note: Use a 1200 mwmum RPM drill for installation. Note: Do not install concrete screws while the dnlJ unit is in impact mode - doing so will destroy the pullout factor of the fastener. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed wtlll a unique spl~ feature whH;li provide$ a fast and safe 1nstalation each bme. When the tace of Ille driver comes into C011!act with the material you are onstaang Into, ccntinue dnlng until nut <river spins free. ~ Is lllen com~. Warranty reqlires Ille use of the appropriate nut drNer for instalalions. 3 -·-.•:.' ... ,,. :·: ~c, SAMMrs· FOR STEEL SAMMYS' FOR STEEL -Vertical Application ' 1114 Blade Nut Driver Pait# 8113910 #14SWRed Nut Driver Part# 8114910 App/1cat1on Product Features • Made with Teks ~ self-driling fasteners • no pre-drilling required. • lnstaUs into steel range from 20 gauge -112" thicknesses. • Saves time from tradibonal methods. • Reduces instaHation costs. • Quick to instal using the Sammys Nut Driver with an 18V cordtess dril/driver. • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. • Made in the U.S.A. ..atc}J • .,. ~" www.itwbulldtx."1tll Apprcv,ii-s Rod P.1,.. \lcdt" Sc-e-~ U t1""J:e UL Tt1-:,t F\1 ..,.e'St ~1m M,H Bet :_i-,t S :J• '4u~~r Oescnp1ons P J ou! o, l0Jd os LOJd lb, Tti1d Th (.k Q•·, ... , , VERTICAL MOUNT 114" 8024957 DSlR 100 • 114-20 x 1" TEKS 3 1510 (20 ga.) .036"-20ga 3116" 25 125 114" 8025967 DST 100 114-14 x 1' TEKS 3 446 (20ga.) 036'-20ga 3.16" 25 125 1/4' 8026957 DST150 114-14x 1-112" TEKS 3 970 (16ga.) 036'-20ga 3116' 25 125 114' 8027957 DST200 114-14x2"TEKS3 446 (20ga.) .035·.20ga 3116" 25 125 114' 8030957 TEK500 12-24 x 1-112" TEKS 5 3125 (3.'16") .188" -3116" 112" 25 125 ®-12 318' 8038957 DSTR 1' 114-20 x 1' TEKS 3 1510 (20ga.) 1500 1475 .036"-20ga 3116" 25 125 ~1?. 318" 8037957 OSTR 1-112' 12-24 x 1-112" TEKS 5 1510 (3116") 1500 1475 060"-16ga. 112" 25 125 ®,~ 318' 8039957 OSTR516 • 511&-18x 1-1WTEKS3 2200 (20 ga.) 1500 1475 036"-20 ga 3116' 25 125 446 (20ga.) 318' 8040957 DST 10 114-14 x 1' TEKS 3 970 (16 ga.) .036'-20ga 3116" 25 125 3.8' 8077925 DSTt~ 1/4-14x 1'TEKS 3 446 (20ga.) 036"-20 ga 3116' 25 125 970 (16ga.) 318' 8041957 DST 15 1/4-14 x 1-112' TEKS 3 446 (20ga.) .036'-20ga 3116' 25 125 970 (16ga.) 318' 8078925 DSTtS.SS 1/4-14x 1-112'TEKS3 446 (20ga.) .036"-20ga l '16" 25 125 970 (16ga.) 318" 8042957 DST20 1/+14x2"TEKS3 446 (20ga.) 036"-20 ga 3116" 25 125 970 (16ga.) 3/8" 8043957 DST25 114-14 x 2-111' TEKS 3 446 (20ga.) 036'-20ga 3116" 25 125 970 (16ga.) 318" 8044957 OST30 114-14 x 3' TEKS 3 446 (20ga.) 036"-20ga 3116' 25 125 970 (16 ga.) ~<:12 318' 8045957 DST516 511&-18x 1·1/4"TEKS3 1500 (3116") 1500 1475 .125'-118' 3116" 25 125 ~1:? 318' 8046957 TEKSO 12-24 x 1-111' TEKS 5 3125 (3116") 1500 1475 .250"-114' 112" 25 125 112" 8031925 OST2.0 114-14 x 2" TEKS 3 446 (20ga.) 188"-3.16" 114" 25 125 970 (16ga.) 1/2" 8033925 DSTR1.0' 114-20 x 1' TEKS 3 1510 (20 ga.) .036'-20ga 3116' 25 125 12' 8034925 DSTR516 • 511&-18x 1-1/4'TEKS3 2220 (20ga) .036'-20ga 3,116' 25 125 112" 8035925 DST5.T6 5116-18 x 1-1/4"TEKS 3 1500 (3116') .125'-118" 3/16" 25 125 112" 8036925 TEK5.0 12-24 x 1-112" TEKS 5 3125 (3116") 188"-3116' 1/2" 25 125 'lnckldes retainv,g nut e SPECIAL NUT DRIVER SYSTEM: The nut driwrs were designed with a Llrique spin-<Jlf fea!Ure which prDYides a fast ancl safe instala!JOO each time. When the face of the driver comes into contact wittt the matenal you are lnstalng into, conbnue drilng unnt nut dnver spins free hslillatioo Is then complete. Wamnfy requites the use o/ the appropriate nut~ for lll5talations. I APPROVALS SWG10 8008957 GST20 8068925 GST20-SS 8010957 GST30 8009925 GST25-380 8022925 SWG25-380 8021957 SWG20 8073925 SWGZO.SS 8269957 SH-GST/CST 20 8269957 SH-GSTICST 20 8139957 SH-GST20 318" 318" 318" 318" 318" 318" 318" 318" 318" 318" 318" Honzontal Veltical Vefbcal Vertical Vartical Honzontal Honzontal Horiz:0ntal 45 • Ang,e off Vemcal 45• Ang,e off Vertical 1 r AntJe o11 Vertical CPVC 1-112" 300 2-1/2" 850 2-112' 850 4" 1500 4" 1500 3-112" • 4~ 1500 2-1/2'" • 3""' 1050 2-1/2" 850 2-112" 850 4• 1500 3' 1050 1.112· 1-112" 4· 1-112" 1-1/2" 1-112" 1-112" 1-112" 1-112" 1-112" 1-112" 1-112" 4• 1475 1475 1475 1 1-112" 1-112" 1-1/2'" SAMMYS FOR STEEL· PIPE HANGER ---Min Steel Thick Max Steel Thick • 8038957 OSTR 1 318' Ve!!Jcal 8037957 OSTR 1-112 318" Veftical 8039957 OSTR 516 318" IJe<tical 8045957 OST 516 318' Vettical 8046957 TEK50 318" Vertical 8055957 SWDR1 318' Horizontal 8066957 SWDR516 318' Horizontal 8054957 SWOR 1-112 318" Horizootal 8137957 SH-OSTR 1 318" 17° Angte off Vertical 8268957 SH-TEK50 318' Verbcal 70° Angle off l/eflical 8150922 XP20 3/W' Vertlcal 8153922 XP35 l'W' VeltJcal 8294922 SXP20 318' Ver1Jeal Of up to 45• 6295922 SXP35 318" \let1ical or up lo 89° 8293957 SWXP35 :i.:s· Honzontal WI FOR CONCRETE· PIIE HANGER 8059957 CST20 3,g· Yenacal 8061957 SWC20 l/8' Horizontal 8150922 XP20 318" Vertical 8150922 XP20 318' Vertical 4" 1500 4' 1500 4• 1500 4" 1500 4' 1500 4• 1500 4• 1500 4· 1500 4· 1500 2-112" 850 4· 1500 2-112" 850 4• 1500 2' 750 3-112" 1250 3-112" 1250 2-112· 850 2-112" 850 .035" .035' .03T .188' .250' .03T .o3r .o3r .035" .02r .060" 027' 060' .060" 4' 4• 4' 4" 4• 4" 4" 4" 4· 'l' 4' 'l' 4' 2' 2" 1475 1475 1475 1475 1475 1475 1475 1475 1475 940 1475 940 1475 635 635 4• 1475 4· 1475 Pre-Pw Strudtnl @ 3000psi f'o6I.Pour Range II LWC s 35 PCF (lbsMI') .105" .105" 105" .188' 188" .060' .060" .060" .106" .029' 105" .029" .125" .029" 029" 3000 3000 PJrt \1 d Rea "1ocnt UL .oJO UL ~I n S:ee ~umber O t> Size D •ec: en R11 ng Os '"'h,c,c"ess SAMMYS FOR STEEL· LUMINAIRE FITTING 8150922 XP20 3M 8153922 XP35 318" 8181922 XP200 114' 8294922 SXP20 318' 8295922 SXP35 318" 8293957 SWXP35 318" Vertical Vertical Vertical Vertical 45• Vertical 90• Honzontal 185 250 185 250 185 250 170 80 250 80 80 .02r .035' .02r .035' .02r .035" .02r .02r .060' ,060" 060" Pan ~lode Roa 1,tcu•t LL Loaa UL M,• S:e,I L sted ,l.i,ohcJt en ~umter Size D1rect1cr R1t1ng !os Th1dr-,e':l--, SAMMYS FOR STEEL· CONDUIT, TUBING, ANO CABLE 8150922 XP20 3/8" Vel1ical 8153922 XP35 3/8" Vel1ical 8294922 SXP20 318. Vertical 8295922 SXP35 3M Vertical 8293957 SWXP35 3/8" Hoozontal 8149957 CZ2000 114' or 318" Orto Vertical Rod Sheet Steel Gauges Gell9I No. 22 ga. 20 ga. Nominal Decimal Equivalent .030' .036" 'SWG 25-380 MaJonun Pl!'" s,:i." ~-.! jlllstall>wed by UL .. 3-1/2" ·SWG 25-380 Ma.1.rr<Jm pipe Slfftn OIOOd tlmberorjoos[ aboledb) IJl io4" ·-swG M • 2-1/2" 283 500 283 500 500 18ga. .048' .027' .060" .02r .060" .060" 1'ga. .060' Max 4 trade size EMT, RMC. and IMC & 5 trade Size rigid PVC condull Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigjd PVC cornnt Max 4 trade size EMT. RMC. and IMC & 5 lrade size rigjd PVC a>ndlnt Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit Max 4 lrade Size EMT & 6 trade sze RMC. IMC, and ngid PVC condutl UL Listed 4516 • CatJle Hanger. cat No. C.22000 Pleoom Rated. 14ga. .075" Compies w/ NEC Standatds 12ga. 105" 1,r .125" ll18" .188" 1/4" .250' UL cami,ln:e 'A'th NEC Star,cta,ds, UL anli FM casts-• performed ,n arnl)llanca with NfPA 13 S!Mdamo. Fnlenlng IIQ<llremerc S llfflK weq,t of W31e!'.flld sehedule 40 pipe s-,s 250 pc,unds, SPECIAL NOTES Engln-rlng Note In 1996, the anchors listed by UL were tested in plate steel that measured . 1ss· and .118' Subsequent tesbng was done for z-purlm applications in May 1997 using ( 03T) or 20 gauge steel. Most recently in 2008, tesbng wrth the new Sammy X-Press was completed us,ng ( 0301 or 22 gauge steel metal deck Sammysc Nut Drivers Speaal nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for 1nstalation, the driver spms freely on the screw after instalabon 1s complete and elim,nates the expected wnst snap, reduces over-torque, and prevents screw fa1klre. Steel Screws Due to variabons In hardness of certain metals. it should be noted that our self-driltng screws for steel wil experience different dril speeds. 500-1500 RPM dnn speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.rtwbuildex.com Sammy• for Seismic Please visit www.ltwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory enYlronments. special care should be taken not just for building attachments but also for the hangers or assembles being supported. Consuh local code authorities for accepted anchoring devices. Composite Jolst/Trun Truss manufacturers vary instalation recommendabons for comp051te )Oisl UL testing was completed to vaidate that Sammys and Sidewinders SWG 20 and SWG 2>380 can be installed into the lop cord of a truss. Sammy GST 20 can be installed into the center ol the lower cord of a composite joist. Penetrauon of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-dnllng may be reqU1Ced by J()ist manufacturers. If so, pre-dril pilot hole 1/8' srnaler than root diameter of fastener Consutt the table below: Model Root Diameter Hole S,ze GST20 .182" 1 8' GST2S-380 1so· 1m· SWG20 182 118' SWG25-380 280" 1m· To increase efficiency of the Installation process, sleeve tools. bd receivers, and wood bits are available for pre-driling. NFPA/NEC Standards Al UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authonty Having Jurisdiction to confirm application and usage. UL Listings / FM Approvals UL and FM reports are available at www.1twbuildex.com ~ ~ ,.._ --~M~.-c...a---.... .r.m .. _,oat--.-: ... Tec~nlcal Drawlns,s . . . . Technical drawings are available and can be downloaded at www.itwbuildex.com 1r1 the following formats· .dwg, .dxf, and .igs. Made In the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service. (800) BUILDEX Option #1 Me< h,1r11c di Anc t1011nq Systpn1~~ KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3. 7 Table 5 -Load adjustment factors for 1/4-in. diameter Hilti KWIK HUS-EZ I in uncracked concrete1•2 Edge distance in shear Spacing factor Edge distance Spacing factor II to and away Cone. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 .L toward edge from edge factor in shear' uncracked concrete I AN I RN I AV /RI/ /RI/ / HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1(2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a i 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 0 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a C 0 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a 0 ,-3-1__.@_ (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a -----.E ~-S 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a Q) 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 0 C: C ·-4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 0) --(127) :a £ 5 0.93 0.80 0.70 0.89 Q) gi 5-1/2 (140) 0.98 0.83 0.72 0.93 Ol Q) 6 (152) 1.00 0.86 0.74 0.97 al .i! ........... ~ 7 (178) 0.92 0.78 1.00 -.c 8 (203) 0.98 0.82 s- Ol C 9 (229) 1.00 0.86 ·o 10 (254) 0.89 0) C. 11 (279) 0.93 en 12 (305) 0.97 14 (356) 1.00 Table 6 -Load adjustment factors for 1/4-in. diameter Hilti KWIK HUS-EZ I in cracked concrete1.2 Edge distance in shear Spacing factor Edge distance Spacing factor II to and away Cone. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 .L toward edge from edge factor in shear' cracked concrete I AN I RN f AV !RI/ JR\/ f HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a ~ 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 0 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a C: 0 (89) n/a 0 3-1__.@_ 0.99 0.80 0.71 0.64 0.76 0.92 ::;E 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a &E ~-:-4-1,lll (105) 0.86 0.75 0.66 0.97 1.00 0.81 0 C: 4-1/2 (114) 1ii ·7 0.89 0.77 0.68 1.00 0.85 ]lg 5 (127) 0.93 0.80 0.70 0.89 u,,, 5-1/2 (140) 0.98 0.83 0.72 0.93 gi, 8l ~~ 6 (152) 1.00 0.86 0.74 0.98 7 (178) 0.92 0.78 1.00 E£ 8 1203) 0.98 0.82 C> C: 9 (229) 1.00 0.86 ·o "' 10 (254) 0.90 Q. en (279) 11 0.94 12 (305) 0.98 14 (356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, f AV' assumes an influence of a nearby edge. If no edge exists, then f ,v • f ,.,,. 4 Concrete thickness reduction factor in shear, f...,.. assumes an influence of a nearby edge. If no edge exists, then f HV -1.0. c::=:::J If a reduction factor value Is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. m Hilti, Inc. (US) 1-800-879-8000 I www.us.hitti.com I en espanol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 321 Me< ll,1111< dl ArH llorn1q Systerns 3.3. 7 KWIK HUS-EZ I (KH-EZ I} Carbon Steel Screw Anchor Table 7 -Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck1,2,3,4,5,s,7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension • q,N0 Shear· <1>V0 Tension -<1>N0 Shear· <1>V0 anchor thread embed. l•c = 3,000 psi 'c = 4,000 psi f'c = 3,000 psi f 'c = 4,000 psi 'c = 3,000 psi 'c = 4,000 psi '"c = 3,000 psi f'c = 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb(kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb(kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNG 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 1/4 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNG 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 -Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck1•2•3•4•5•6•7.a Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension -q,N0 Shear -<1>V0 Tension • <1>N0 Shear -q,V0 anchor thread embed. ''c = 3,000 psi f 'c = 4,000 psi lf'c = 3,000 psi V'c = 4,ooo psi f"c = 3,000 psi V'c = 4,ooo psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in.(mm) lb(kN) lb(kN) lb (kN) lb (kN) lb (kN) lb(kN) 1-5/8 280 305 610 610 330 360 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) UNG 2-1/2 605 700 610 610 635 735 1/4 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) 1-5/8 280 325 915 915 330 380 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) UNG 2-1/2 605 700 915 915 635 735 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h"°"' (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. f'c = 3,000 psi f 'c = 4,000 psi (20.7 MPa) (27.6 MPa) lb (kN) lb (kN) 610 610 (2.7) (2.7) 610 610 (2.7) (2.7) 915 915 (4.1) (4.1) 915 915 (4.1) (4.1) 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by a ...... = 0. 75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth -a. ..... = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth -a.,...., = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espariol 1-800-879-5000 I Hilti (Canada) Corp. t -800-363-4458 I www.hllti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3. 7 Figure 2 -Installation of Hlltl KWIK HUS-EZ I (KH-EZ J} In sofflt of concrete over steel deck floor and roof assemblies Min. 4-1/2" Min. 1-1/4" -- Min. 4•1/2" ~ FIUteedge Min. 12• (typical) (ridge) Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. ~ 3.3. 7 .3.2 Canadian Limit State design II Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 -Steel resistance for Hilti KWIK HUS-EZ I carbon steel screw anchor1.2 Nominal Internal anchor thread Tensile3 Shear' Shear6 diameter diameter N.., v.., V ""·"" in. (UNC) lb (kN) lb(kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N.., = A,.,. <I>, f.,.. Ras noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with v_ < A ... v <I>, 0.6 fut, Ras noted in CSA A23.3-14 Annex D, 5 Seismic shear values determined by seismic shear tests with V ...... < A ... v <I>, 0.6 f,,. Ras noted in CSA A23.3-14 Annex D. See section 3.1 .8. 7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espanol 1-800-879-5000 I Hitti (Canada) Corp. 1-800-363-4458 I www.hiltl.ca I Anchor Fastening Technical Guide 2016 323 MP< l1,u11cJI Arn IHmnq Systerns 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 -Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 Iii Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 AnchorO.D. ct. in. 1/4 (mm) (6.4) Effective embedment2 in. 1.18 1.92 het (mm) (30) (49) Minimum nominal embedment2 hnom in. 1-5/8 2-1/2 (mm) (41) (64) Minimum concrete thickness in. 3-1/4 4-1/8 h,,,., (mm) (83) (105) Critical edge distance in. 2.00 2.78 cac (mm) (51) (71) Minimum spacing at critical edge distance in. 1.5 5min,cac (mm) (38) Minimum edge distance in. 1.50 cmln (mm) (38) Minimum anchor spacing at minimum edge distance for s > in. 3.0 (mm) (76) Mininimum hole depth in concrete in. 2 2-7/8 ho (mm) (51) (73) Minimum specified ultimate strength futa psi 125,000 (N/mm") (862) Effective tensile stress area in2 0.045 A,.,N (mm") (29.0) Steel embed. material resistance factor for reinforcement <I> -0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R -0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R -0.65 D.5.3 Factored steel resistance in tension N.., lb 3,370 D.6.1.2 (kN) (15.0) Factored steel resistance in shear v .. , lb 750 D.7.1.2 1/4-20 UNG (kN) (3.3) internal thread lb 335 Factored steel resistance in shear, seismic v..,_"' (kN) (1.5) Factored steel resistance in shear V lb 725 D.7.1 .2 3/8-16 UNG sar (kN) (3.2) internal thread lb 620 Factored steel resistance in shear, seismic V SN,eq (kN) (2.8) Coeff. for factored cone. breakout resistance, uncracked concrete k ... -, -10 D.6.2.2 Coeff. for factored cone. breakout resistance, cracked concrete k,,, -7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked cone.• lj/eN -1.0 D.6.2.6 Anchor category --3 1 D.5.3 (c) Concrete material resistance factor <I>. 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R 0.75 1.00 D.5.3 (c) Condition B5 Factored pullout resistance in 20 MPa uncracked concrete6 lb 665 1,645 0.6.3.2 N pr.uncr (kN) (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concrete6 N lb 340 815 D.6.3.2 pr,c, (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete6 lb 275 815 D.6.3.2 Npr,eq (kN) (1.2) (3.6) 1 Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. 2 See figure 1 of this section. 3 The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section D.2. 4 For all design cases, lllc.N = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k.,c,l or uncracked concrete (k •. ..J must be used. 5 For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. 6 For all design cases, lll •.• ~ 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hitti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espanol 1 ·800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3. 7 Table 16 -Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels1•2 Min. effective Allowable load3 Ultimate load Hanger rod size embedment h .. in. Tension lb Shear lb4•5 Tension lb Shear lb4·5 1/4-20 UNC 485 1,930 1-3/8 455 1,810 3/8-16 UNC 755 3,025 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimension! configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear~ val\Je$ should consider the SCtew 01' threaded rod steeC strength. Figure 3 -Installation of Hilti KWIK HUs-EZ I (KH-EZ I) in hollow core concrete 3.3. 7 .4 Installation Instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3. 7 .s Ordering information1 Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/box KH-EZ 1/4x1-5/8 11/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/2 I 1/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/8 I 3/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/2 I 3/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in Inches. m Hilti, Inc. (US) 1-800-879-8000 I www.us.hilti.com I en espariol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hllti.ca I Anchor Fastening Technical Guide 2016 327 @TOLCO Fig. 25 -Surge Restrainer Size Range -One size fits 3/4" thru 2" pipe Material -Pre-Galvanized Steel Function -Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals -Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish -Pre-Galvanized Order By -Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344, 108 c@m UfflD COOPER 8-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 ,,,, COOPER B-Line TCLCO www.tolco.com NI Be□· Re1,1~1or 8, J .'L )'.) Fig. 98 -Rod Stiffener Size Range -Secures 3/8" thru 7/8" hanger rod Material -Carbon Steel Function -Secures channel to hanger rod for vertical seismic bracing. Approvals -Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load. spacing and placement information relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines Finish -Electro Galvanized Note -Available in HOG finish or Stainless Steel materials. Order By -Figure number Fig. 99 -All Thread Rod Cut to Length Size Range -Secures 3/8" thru 7/8" rod in 1" increments Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -Figure number, rod diameter, rod length and finish Fig. 100 -All Thread Rod Full Lengths Size Range-Secures 3/8" thru 7/8" rod in 10' lengths Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F WtJ100 1/4 240 215 12 318 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3no 3360 169 4960 4420 222 1¼ 8000 7140 360 1½ 11630 10370 510 Component of State of @ California OSHPD Approved e 'IL a una Seismic Restraints System Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 7/8 2710 3no 2420 3360 ■ OFrlCUMANUFACTURING FACILITY· 137, SAMPSON ~VE • CORO~A CA 92879 • P~ 951 737 S599 • FAX 0517370330 CUSTOMER SERVICE • 800 786 )266 www.tolco.com Pipe Hangers Fig. 200 -"Trimline" Adjustable Band Hanger (Cooper B-Une Fig. B3170NF) Fig. 200F -"Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Une Fig. B3170NFF) ®TOLCO c@ us Fig. 200C -"Trimllne" Adjustable Band Hanger with Plastic Coated (Cooper B-Une Fig. B3170NFC) Fig. 200S -"Trlmline" Adjustable Band Hanger with Non-Captured Nut La'rEI ~ Size Range: Fig. 200 -112" {15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: • (112" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. • (2112" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (112" (15mm) thru 8" f200rrvn)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) {J/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1192A, Type 1 O and Manufacturers Standardization Society ANSVMSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343'C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS2-0. Pipe Size Rod Size Part No "' mm •112 112• (15} 3/a"-16 za.3/4 3/4" (20} 3/a"-16 •1 1· (25} 3/a"-16 -11/4 11/4" (32) 3/a"-16 •1112 P/2" (40) 3/a" -16 •2 2· (50) 3/a"-16 •2112 21/2" (65) 3/a"-16 -3 3• (75) 3/a"-16 -31h 31/2'' (90) 3/a"-16 20IM 4• (100) 3/a"-16 211N 5• (125) W'-13 .. 6" (150) 112•-13 .. s· (200} 1/2''-13 Fig. 200C A ,n 1mmi ,n 31/a" (79.4) 25/a" 311s· (79.4) 2112· 33/a" (85.7) 25/g" 33/4" (94.0) 27/a• 37/a" (98.4) 27/s" 4112" (114.3) 3• 55/g" (142.9) 41/s" 57/a" (149.1) 4• 73/a" (187.3) 51/4" 73/g" (187.3) 5" 91/s" (231.8) 61/4" 101,a• (257.2) 63/4" 131/s'' (333.4) 83/4" B 1mm (66.7) (63.5} (66.7) (73.0) (73.0) (76.3) (104.7) (101.6) (133.3) (127.0) (158.7) (171.4) (222.2) Flg.~11o~2 Fig. 200F Approx Wt /100 lbs kg I 11 (5.0) 11 (S.O) 12 (S.5} 13 (S.9) 14 (6.4) 15 (6.9) 27 (12.3) 29 {13.3} 34 (15.6) 35 (16.0') 66 (30.2) 73 (33.4) 136 (62.3) Fig. ~1/z. :zoo.S/4 fig. ~21/z lo 200-8 Ag.200 Fig. 200S All dimensions lo charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless othefWise specified. Ag. 200M -"Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 -112" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: • (112" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (2112" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed r12• (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(-¼" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplfed with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM OS 2-0. Pipe Size Rod Size Part No ,n mm ,n 2Dllll8-1h 112• (15) MS 31/s" 2GOM1•1h 112• {15) MlO 31/s" 2111118-3/4 l/4" (20) MS 31/s" 2GOM1cµ/4 3/4• (20) M10 31/s" 2DIIIIB-1 1· (25) MS 33/s" 2GOM1•1 1· (25) Ml O 33/s" 2DIIIIB-11 /4 l1/4" (32) MS 33/4'' 2GOM1•11,, 11/4" (32) M10 33/4" 2DIIIIB-11 h 11/2" (40) MS 37/s" 211111t1•11h 1112· (40) M10 37/s" 2DIIIIB-2 2· (50) MS 41/2'' 2GOM1•2 2· (50) MlO 41/2'' 2GDM-2"h 2112· (65) MlO 55/a" 2GDM-3 3• VSJ M10 57/s" 2111111-31 h 3112" (90) MlO 73/s" 20llll-4 4• (1()0) Ml O 73/a" 2111111-5 5• (125) M12 91/s'' 21111M 6" (150) M12 101/s" 2GOIH s· 1200) M12 131/a" A 1mm1 ,n {79.4) 25/a" (79.4) 2.5/s" {79.4) 21/z'' {79.4) 21'2" (85.7) 2.5/s" (85.7) 2.5/s" (94.0) 27/s" (94.0) 27/g" (98.4) 27/s" (98.4) 27/s· (114.3) 3• (114.3) 3• (142.9) 41/s" (149.1) 4• (187.3) 51/4" (187.3) 5• (231.8) 61/4" (257.2) 63/4" (333.4) 8¾" B 1mm, (66.7) {66.7) (63.5) (63.5) (66.7) (66.7) (73.0) {73.0) (73.0) (73.0} (76.3) (76.3) (104.7) (101.6) (133.3) (127.0) (158.7) (171.4) (222.2) Pipe Hangers Fig. 200-1 ID 200-2 Approx. Wt /100 lbs 1kg1 11 {5.0) 11 (5.0) 11 (5.0) 11 (5.0) 12 (5.5) 12 (5.5) 13 (5.9) 13 (5.9) 14 (6.4) 14 (6.4) 15 (6.9) 15 (6.9) 27 (12.3) 29 (13.3) 34 (15.6) 35 (16.0) 66 (30.2) 73 (33.4) 136 (62.3) (' A <i'TDLCO c@us Uffll Fig. 200-1'2. :zoo.3/• Fig. 200-2½ ID 200-8 All dimensions in charts and on drawings are in inches. Dimensions shown 111 parentheses are In mimmeters unless otherwise specified. Pipe Hangers Fig. 200H -Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (100mm} trapeze pipe size. Material: Steel -Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with 3/s"-16 or 1/2"-13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada·· (cUL). Conforms to Federal Specification W'N-H-171 E & A-A-1192A. Type 10 and Manufacturers Standardization Society ANSVMSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. Pipe Size Rod s,ze A Part IJo ,n mm ,n 1mm1 ,n 20DH-2.3/I 2" (50) 3/a"-16 49'16" (115.9) 37/32" 20IIH-2-1h 2· (50) 1'2"-13 423/32" (119.8) 33/g" ~1h.3Ja 2112· (65) 3/s"-16 5Sf15" (134.9) 323/32• 20DH-21J2-1h 21/2" (65) ½"-13 515/32" (138.9) 37/s" 20DH-3-3/1 3• (75) 3/s"-16 5¾" (146.0) 327/32" 20DH-3-1h 3• (75} 112•-13 57/s" (148.1) 331/32• 2IJIIIM.3/I 4" (100) 3/a"-16 67/e" (174.6) 47116" 2IJIIK+1h 4• I (100) ½"-13 71/32" (178.6) 419/32" B A B Approx. Wt /100 imm1 lbs 1kgl (81.7) 48 (21.8) (85.7) 45 (20.4) (94.4) 59 (26.7) (98.3) 56 (25.4) (97.6) 63 (28.6) (100.8) 60 (27.2) (112.7) 76 (34.5) (1116.7) 73 (33.1) • Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. "All sizes are UL Listed to support up to 8' pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. f)T OLCO c@us UITBJ Al dimensions in charts and on drawings are in inches. Dimensions shown in parentheses ate in milfimeters unless otherwise specifted. Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining• and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F. LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFi~ is not harmful to the skin. Design Criteria/Data • Water dispersible • Applies equally well to wet or dry surfaces • Suitable for all types of pipe lines, including potable water • Excellent working range -10° to 150° • Will not support bacteria • Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe • FGG/BM/CZ'w System Compatible Program• • Certified to NSF/ ANS/Std 61 -G *FBC'M System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 UONSHEAO AVE CARLSBAD, CA 92010 TEL+ 1 760 599-1168 + 1800344-1822 FAX + 1 800 344-3775 Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. •• C 2012 Fire Protection Products, Inc. FPPi-, LubeFi~ are registered trademarks of Fire Protection Products, Inc. • 1j FGGIBMICZ", Blaze-Maste,., RowGuard Gold" and Corzan• are registered trademarks of Noveon IP Holdings Corp. ~ IN u ...... Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 2Ib (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. SRN DIEGO SERL, INC. 7635 RONSON ROAD • SAN DIEGO, CA 92111 • TEL: 858-278-3270 • FAX: 858-278-2950 E-MAIL: sales@sandiegoseal.com • VISIT US AT: www.sandiegoseal.com PTFE Thread Sealant Tapes Made In the USA ur thread sealant tape breaks clean without shredding r warping, identifying it as a product that can be trusted o perfonn reliably when the job is completed and the ressure is on. I h-Dens Thread Sealant Ta Standard Grade Our standard grade PTFE Thread Sealant Tape is for those applications that do not require the sealing properties of a premium grade thread sealant This is intended to be used for general purpose sealing in pipe threads. The standard density virgin PTFE sealant tape permits quick, dean, economical sealing of male pipe threads of all sizes and reduces the risk of system contamination common with liquid and paste sealants. tis effective and efficient so you can use less tape. • Tears cleanly ... seals neatly • aua sealing: This premium high density PTFE sealant tape pennits quick, clean sealing of male pipe threads of all sizes and eliminates the risk of system contamination common with liquid and paste sealants. • Self-lubricating: The self-lubricating quality of this unsintered tape makes joints easy to assemble and disassemble, and extends the fatigue life of sealed connections. • Durable: Totally maintenance free premium high density PTFE thread sealant tape i virtually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (-240°C) to +500°F (+260°C), and pressures from hard vacuum to 10,000 PSI. Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. *FBC'M System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+ 1760599-1168 + 1 800 344-1822 FAX+ 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF TH IS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. C 2012 Fire Protection Products, Inc. FPPI'", LubeFi~ are registered trademarks of Fire Protection Products, Inc. FBC'", BlazeMaster3, FlowGuard Gold9 and Corzan• are registered trademarks of Noveon IP Holdings Corp. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIG 1 gl. 5 gl. 55gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Features • Heavy Duty Cutting Oil • Excellent Tool Life • Chlorine Free • All types of ferrous metal or pipe • Improved Surface Finish • Low Odor • Low Smoke FBe SYSTEM COMAI.TlBlE ·FBC'M System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gol~. BlazeMaste,.e, and Corzan® pipe and fittings. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears~ Manufacturing to be compatible with Flameguarcr pipe and fittings. 3198 LIONStEAD AVf. CARLSBAD, CA 92010 TEL + l 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. •• C 2013 F,re Protection Products, Inc. FPPf', ThreadRC'-are registered tJademarks of Are Protecdon Products, Inc. • .... ~ -· ........ Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hotline. They may be reached at 1 800 424-9300 . Pipe. Clamps TOLCOTIII Fig. 25 -Surge Restrainer Size Range: -One size fits 3/4" 120mm) thru 2' (40mm) pipe. Material: -Pre-Galvanized Steel Function: -Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 201 0 edition, 9.2.3.4.4.1 and 9.2.3.4.4 4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: -Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Part number and band hanger, size from 3/4' (20mm) thru 2' (40mm). Patent #5,344, 108 Part No. 25 Approx. Wt/100 Ills. lktl 4.8 12.21 I ' ' ' . ' ' . ' ',, '_tJJ_-,,._.. -~/\ ,' , ~I' ' ':, / ./' --:-<:~\. " .... ,, " "' . ' '' '' -----...... .. .. .. ---.. .. .. . .. , , , '. , . ,': .. , . . , . ' .. .. . .. .. .. -::, .. .. , .. ~: ~:::: ...... 1:@111 Uffll All dimensions 1n charts and on drawings are in inches. Dimens1011s shown 1n parentheses are 1n m,nimeters unless otherwise specified. Eaton 99 B-Line series Pipe Hangers & Supports Beam Clamps TOLCO™ Fig. 65 -Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening TOLCO'11 Fig. 65XT • Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) Size Range: Fig. 65 -l/2'-13 rod sizes, and 5/e'-11 rod sizes Fig. 65XT -3/a'-16 rod size (see below ) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" 090mm}. Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed In the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, 3/s'-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe 1/2'-13 rod will support 1/2" 115mm) thru 8" 1200mm) pipe Component of State of California OSHPD Approved Seismic Restraints System c®• Uffll s/i D Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD}. For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Set Screw and Locknut Included Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Part number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D No. 65-1/z 65-SJI Part No. A 1/2" -13 5/8" -11 11/4" (31.71 11/4" (31.7) in.. tl/2" 1'/2" Inn) i•. (38.1) 3/4" (38.11 3/4" Mac Rec. Load • lbs. (kN) 1130 (5.02) 1130 (5.02) Inn► in.. 119.0) 1" (19.01 1· Approx. Wt./100 lbs. (kg) 55 124.9) 55 (24.9) • Maximum loads tor clamp with set screw in up or down position. Note: See page 27 for recommended setscrew torque. (mm) (25.4) 125.4) Fig. 65XT .3/a -Beam Clamp c®• ~ Uffll Feature: Extruded holes allow for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 -28.0 Lbs. (1 2.7kg) Design Load: 730 Lbs f3 25kNl Finish: Plain or Electro-Galvanized Order By: Part number and finish Approvals: Underwriters Laboratories Listed in the USA (UL} and Canada (cUL). and Factory Mutual Engtneenng Approved (FM) for up to 4" 1100mm) pipe. Note: See page 27 for recommended setscrew torque. E in.. lnnl 9/16" (14.31 9/15" (14.31 Set Screw and Locknut Included 13/( 134.9) 1!tf' 122.2) All dimensJOOs n charts and on drawings are In inches. D1menStOOs shown In parentheses are In m1ll1meters unless otherwise specified. Eaton 33 8-L1ne series Pipe Hangers & Supports TOLCO™ Fig. 69R -Retrofit Capable Beam Clamp Retaining Strap Size Range: 3/a'-16 & 1/2'-13 rod 4" (101,6mm) thru 16" (4064mm) lengths Note. longer lengths are available consult factory Material: Pre-Galvanized Steel Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13. Features: Beveled locking slot• Is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown In Section "A-A" or inverted. Allows easy 1nstallat1on for new construction or retrofit applications. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind, such as a hex nut or the beveled locking slot of the Fig. 69R will provide a more secure reliable installation. Approvals: Underwriters l aboratories Listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in the Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load spacing and placement information relating OSHPD projects, please refer to the Seismic Restraint System Guidelines. Finish: Pre-Galvanized Order By: Part number, length, and finish. Note: Minimum return on strap Is 1 " 125.4mm) * Patent #5,947,424 Slot Width For Use With Part No. in. (mm) 69R-l/l,-L 1/J&" (11.1) B3033-3/a, B3034-3/s, B3031-3/a, 65-3/s, 65XT-3/a, 66-3/s 69R-1/2-L 9/15• (14.3) B3033-1/2, B3034-1/2, 65-1/2, 66-1/2 Length Specify Specify Beam Clamps Component of State of California OSHPD Approved Seismic Restraints System A-A All dimenst0ns in charts and on drawings are In inches. D1mens1oos shown 1n parentheses are In m1lhmeters unless otherwise specified. B-Line series Pipe Hangers & Supports 38 Eaton TOLCO -' . l' ,l. IP l' . ,lll)..:l' () '· ,llh . \I' www.tolco.com NIBCO H,·'IISIC'1 1. 1 ) . UU8 Fig. 98 -Rod Stiffener Fig. 988 -Rod Stiffener w/Break-off Bolt Head Size Range -Secures 3/8" thru 7/8• hanger rod Material -Carbon Steel Function -Secures channel to hanger rod for vertical seismic bracing. Approvals -Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development CQSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish -Electro Galvanized Note -Available in HOG finish or Stainless Steel materials. Order By -Figure number Fig. 99 -All Thread Rod Cut to Length Size Range -Secures 3/8" thru 7/8" rod in 1 " increments Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -Figure number, rod diameter, rod length and finish Fig. 100 -All Thread Rod Full Length Size Range -Secures 3/8" thru 1 ½• rod in 10' lengths Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Component of State of California OSHPD Approved Seismic Restraints System FIG. 98 FIG. 988 Dimensions Rod Ma.x. Rec. Load Lbs. Size For Service Temp 650°F 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 Note -Available in Electro-Galvanized and Dimensions • Weights HOG finish or Stainless Steel materials. Max Rec. Load Lbs. Order By -Figure number, rod diameter and finish Rod For Service Temps Size 650°F 1/4 240 3/8 730 1/2 1350 5/8 2160 3/4 3230 7/8 4480 1 5900 1¼ 9500 11h 13800 ■ omCEJMANUFACTURIN6 FACIUTY • 1375 SAMPSON AVE •CORONA, CA 92879•PH 951 7JI 5599 •FAX 951 7370330 CUSTOMEI SQMCE • 800786 5266 www.talco.com Approx. WU100 12 29 53 84 123 169 222 360 510 SAMMY$® FOR WOOD SAMMYs·• FOR WOOD -Vertical Application ' #14 Black NutDnwr Patt iJ 8113910 #14 SW Red Nut Driver Part# 8114910 Appl,cat,on Producr Features l'lotlffl il1an T--~ l'lot-. .... 3"......., lhCl<nes$ (2,. t Tl (dlplh"'..,. ytlflcll rntmbtf) Composite I Truss ' '' • No pre-drilling required • Quick to ,nstaa using the Sammy Nut Driver with an 18V cordless dnlVdriver. • Saves lime from tradibonal methods. • Reduces lnstaffalion costs. • Manufactured In the U S A ~pcr-:,JI~ R;l: P.H1 l\tc\~el S:rt>1i1 l.ltmltr> ..... T~.,, F\ITt''>t 5('1. :,, S .:.t' r'-tumbe-• 0t-5C' C' ,: ,, P.,lki,,t lb-s Li... lJ C''> L:,,.ll1 lb.-.. Jty -...·, VERTICAL MOUNT 114" 8002957 GST 100 1/4 x 1· 210 (7116" OS8) 25 125 670 (314" Ply) 114" 8003957 GST200 14x2' 1760 (Fr) 25 125 ® 318" 8007957 GST10 114 I 1" 210 (7116"058) 300 25 125 670 (314" Ply) 318" 8008957 GST20 14 x 2' 1760 (Fr) 850 1475 25 125 318" 8068925 GST20,SS 114 X 2' 1760 (Fr) 850 25 125 318" 8009925 GST25-380 3/8x 2-112" 2113 (Fir) 1500 25 125 3/Pf' 8010957 GST30 114 x3" 2060 (Fr) 1500 1475 25 125 318" 8069925 GST30-SS 1413" 2060 (Fir) 25 125 1fl" 8013925 GST2 114 I '2" 1760 (Fir) 25 125 1/2' 8015925 GST3 1413" 2275 (Fr) 25 125 e SPECIAL NUT ORNER SYSTEM: The nut drnlers wem cleslgned W1111 a l#ltqlle spilH>ff reature which pm,des a fast and safe ~anon each bme When the laced tile dlNer comes lfl1o cootac:t with ll'le malenal you are mlal111!J onto. c:ontlnue crtlfing unlll nut dtlver spins free lnstalabon ~ then cc,mQiete. Warrant, requ,t9$ the use d tile awopnate nut dnve, to, mtallations. I SIDEWINDER·" FOR WOOD -Horizontal Application ··~~{ Nut Driver Part# 8114910 App/1cat1on Product Features Not less than 2 nominal wldlh (1-1/2') up 10 3-112" pipe; not le$$ than 3" (2-1/21 nominal width 4• & 5· pipe ._____. M1n1mum 2-112" from bottom for branch lines. M'1n1mum 3" from bot· tom for main lines. Exception Thi$ requirement shal not apply 10 2· 01 lhicker nailing strip$ resting on rop of steel belll11$. )If Floor Joist • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drilVdnver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured In lhe U.SA ~)d P1rt ScreA Ul!Hnate UL Te'): Bc1. ~ 1 , AporcJJl'S St.!t' \umt>er \,1od~ o~.,L'lCt J(i') P'4/lout Its LC'JC lt'S Otw c.·. HORIZONTAL MOUNT 1/4' 8019957 SWG200 1/4 X 2" 1725 (Fw) 25 125 318" 8020957 SWG10 1/4 X 1' 622 (Fir) 300 25 125 318' 8021957 SWG20 1/4 X 2" 1725 (Fw) 1050 25 125 1'8' 8073925 SWG20-SS 1/4 X 2" 1725 (Fir) 850 25 125 J/8"" 8022925 SWG 25-380 J/8 X 2·1/2' 2249 (Fir) 1500 25 125 l8" 8023925 SWG30 1/4 X 3" 1884 (F~) 25 125 'May rtqUlr& ~ cond,dst ma11Jfactwer SAMMYS SWIVEL HEAD™ FOR WOOD -Swivel Application #14Blacx Nut Drive, Part# 8113910 #14 SH Orange Nut Driver Part# 8273910 Appl1cat1on Product Features • Eliminates distortion of threaded rod. • Accommodates up to 3 ½' x 12 pitch roof. • Allows 17" deflection from vertical. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in lhe U.SA ~.,;,d p )rt Ser~~ lj t1,.,...J:e i. •• L Te-,• l~dC =\1 ·-:.".,t ',1 '1 Bot ..... ApcL.1JI, S,u t>t_,mb?r M ... cel De'1Ul►•ic~-, ='l, ,.:lit o-, lb'S ... .:-Jd 1t':t T!iid ~t.·~-. Jt, .. •. SWIVEL MOUNT J/8' 8139957 SH--GST 20 1/4 X '2' 1257 (Fir) 1050 1475 25 ~ 31-S-8269967 SH-OST/CST 20 S/16 x 1-3/4" 1903 Dim. lumber 1500 1406@ 45"olf vertlC8I 850@45° 25 Dtin.Llrier 903 Dim. lumber 1/2" 8J03957 SH-GST/CST 2.0 S/16 x 1-314" 1406 @ 45'oll vertical 25 125 04m. LLn!ber • May rtQ1,,rw prl-<lrillng: consut)OISt manu'3dllllf