Loading...
HomeMy WebLinkAbout6005 HIDDEN VALLEY RD; 200; FPC2021-0151; PermitPERMIT REPORT Fire Permit Print Date: 10/13/2021 Job Address: 6005 HIDDEN VALLEY RD, # 200, CARLSBAD, CA 92011-4225 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: Valuation: Occupancy Group: #of Dwelling Units: 2120406600 Track#: $288,362.00 Lot#: Project#: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: PARTNERS ADMIN -SPRINKLER Tl (29 HEADS) Applicant: TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611A S MELROSE DR VISTA, CA 92081-5407 (760) 525-4329 FEE FIRE NFPA 13 or 13R System 7-100 heads Total Fees: $553.00 Fire Department Total Payments To Date: $553.00 {city of Carlsbad Permit No: FPC2021-0151 Status: Closed -Finaled Applied: 08/12/2021 Issued: 09/21/2021 Finaled Close Out: 10/13/2021 Inspector: Final Inspection: FPContractor: TOTAL FIRE PROTECTION INC 1611 S MELROSE PL, # 244 VISTA, CA 92081-5471 (760) 525-4329 Balance Due: AMOUNT $553.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov · Bulletin 014 Rev. L Reliabld Model F1 FR Series Quick Response Standard Spray Model F1 FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F1 FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model F1 FR56 Concealed Sprinkler Types Standard Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler Types Standard Upright Standard Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Recessed Sprinkler Types Standard Pendent Model F1 FR56LL & F1 FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH 5. *NSF Certified to NSF/ANSi Standard 61 Annex G 6. EC Certificate: 0786-CPD-40239 (RA 1414 }, 0786- CPD-40251 (RA 1425), 0786-CPD-40252 (RA 1475) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1 FRXLH & F1 FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1 FRXLH & F1 FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR56, F1 FR56LL, Upright Pendent Vertical Sidewall Horizontal Sidewall y ~ • f .. Conventional Recessed Pendentif 1/F2 '---------' :{;.~i~:._ ·. :., ~ .. ~. ·:.> J ;': Recessed Concealed .___R_ec_e_ss_e_d _ _, Horizontal Sidewall Pendent PendentifP XLH Upright XLH Pendent F1FR42, F1FR42LL, F1FRXLH & F1 FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- XLH Recessed Pendent F 1 /F2 .__ ____ ___, rately controlled amount of special fluid XLH Recessed hermetically sealed inside a precisely Pendent FP manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford , New York 10523 co C i. ::, 0 .J. ~ :0 (D :< r Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. *Pin tie (XLH Onry) Deflector Washer Frame 014FG06A Load Screw Bulb Cup Model F1 FR42, F1 FRXLH Upright Technical data: Thread Max. Min. Temperature Models Discharge Coefficient Response Working Working Finish Size Pressure Pressure Rating F1FR56 K 5.6 **F1 FR56LL<1> F1FR42 Quick 1/2" NPT See See **F1 FR42LL<1> K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature "Finish Table" F1FRXLH Ratings" Table. F1FR28 K 2.8 c,1 Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Deflector Load Screw *Pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape CDA Alloy510 2. Model F1 FR56, Upright, Pendent & Conventional Sprinklers Model F1 FR42, F1 FRXLH & F1 FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Orifice Size us Metric Height Organization Sprinkler Identification Number (SIN) Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2" (15mm) P) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3, 4, 6 7/16" (10mm) 1 /2" NPT (R 1 /2) 4.2 60 2.25" (57mm) 1 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 Conventlonal-lnstall In Upright or Pendent Position 15mm<1) 1/2" NPT (R1/2) 5.6 80 11> cULus listed corrosion resistant (Polyester coated) sprinkler. <2> Polyester coated FM approved sprinkler. 57mm <3> Polyester coated LPCB & VdS approved sprinkler RA 1425, RA 1414 & RA 1475. 1•> Electroless Nickel PTFE (Teflon_.)* Plated -cULus listed Corrosion Resistant Upright Pendent Model F1 FR56LL & F1 FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprlnkler Orifice Size us Metric Height 3,4, 6 Approval Organization Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm) 11> 1/2" NPT (R1/2) 5,6 80 2.25" (57mm) 1, 5 7/16" (11mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1, 5 <1> cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark 3. RA 1425PX2X3X4) RA 1414PX2X3X4) RA1423PX4) RA 141 31•> RA 1421(1X4) RA1411I•> RA1475<3> Conventional Sprinkler Identification Number (SIN) Pendent RA1415 RA1410 Model F1 FR56, F1 FR42, F1 FRXLH & F1 FR28 Quick Response Recessed Pendent Sprinkler<1> Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number Orifice Size us Metric Height (SIN) 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA141 3 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA 141 1 11> Refer to escutcheon data table for approvals & dimensions Model F1 FR56LL & F1 FR42LL Quick Response Recessed Pendent Sprinkler<1> Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Orifice Size us Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 7/16" (10mm) 1 /2" NPT (R 1 /2) 4.2 60 11> Refer to escutcheon data table for approvals & dimensions ModelF1FR56,F1FR56LL,F1FR42, F1FR42LL, F1FRXLH& F1FR28 F1 or F2 Sprinkler Height 2.25" (57mm) 2.25" (57mm) Sprlnkler Identification Number (SIN) RA1415 RA1410 t • X , /2• REIJUClR rACE or FrrTWG 7D TN:£ or CDUNQ OIMDISION AT -R£tfS$ -t-t/2T»mm] AT lilNIUfl RfC£SS • t f15.4mm} T ...:,ss -1/t1T,.,"'""'1 AT JIINMM llfttSS' • f 115..f.mni} J t/4"'(¥,t. [U,,-,J ModelF1FR56,F1FR56LL,F1FR42,F1FR42LL,F1FRXLH& F1FR28 FP Model F1 FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler Thread Size Identification Orifice us Metric Height Organizations Numbers (SIN) ½" (15mm) ½" NPT (R1/2l 5.6 80 2.25" (57mm) 1, 2, 3 RA 1485l2X3> 15mm ½" NPT (R1/2) 5.6 80 2.25" /57mml 3(1) l1> LPC Approval is for pendent position only. l2> cULus Listed corrosion resistant (Polyester coated) sprinkler. <3> Electroless Nickel PTFE (Teflon~)* Plated -cULus listed Corrosion Resistant Vertical Sidewall *DuPont Registered Trademark 4. Sprinkler Type Uoriaht Pendent Deflector to Celling Distance {Min. -Max.) 4" 1102mm) -12" (305mm) 4" /102mm)-12" (305mm) Model F1 FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Si dewall Nominal K Factor Nominal Orifice Thread Size Sprinkler Height Approval Organizations and Type of Approval us Metric Light Hazard Ordinary Hazard ½" (15mm) ½" NPT (R1/2) 5.6 80 P> cULus Listed corrosion resistant (Polyester coated) sprinkler. <2> Polyester coated FM approved sprinkler. 2.63" (67mm) (3> Electroless Nickel PTFE (Teflon•)* Plated -cULus listed Corrosion Resistant 1, 2 1 Sprinkler Identification Numbers (SIN) RA 1435(1X2~3J ~-----------------------------, Horizontal Sidewall FACE OF FlmNG TO FACE OF Cf /LING 0I/JfNSION Ft ESCUTCHEON AT /JAXI/JU/J RECESS • I 125.4mm] AT /JINI/JU/J RECESS • J/B19.5mm} f2 [SCUTCHEON AT /JAXI/JU/J RECESS • J/41l9mm} AT /JINI/JU/J RECESS • J/819,Smm} 2 I/•" HOLE DIA. {57.2mm] TURN COLI.AR UNnL TIGHT AGAINST SPRINKLER WRENCH BOSS. WWW7/21 @ fl £SCtJTCHEON AT /JAXI/JU/J RECESS • I-J/B1J4.9mm] AT /JINI/JU/J RECESS • 2-1/I6"{52.•mm] f2 ESCUTCHEON AT WJ<//JUIJ RECESS • 1-5/81• I.Jmm] AT /JINI/JU/J RECESS • 2-l/l6"{52.4mm} 2 27/J2" DIA {72.2mm] j I fl ESCtJTCHEON 1--J/•1l9mm] ADJUST/.lfNT F2 ESCUTCHEON 1/21I2.lmm} ADJUST/.lfNT (I) 4"-12" {l0I.6mm-J04.8mm] Cf/UNG TO DEFLECTOR RECESSED HSW W/FJ OR F2 ESCUTCHEON (I} F/J APPROVED FOR •• -6" {I0I.6/J/J -I52.4/J/J] Cf/LING TD DEFLECTOR WITH F2 ONLY. Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with F1, F2 or FP escutc heons for "Lig ht Hazard" only. While FM limits use for the same hazard with the F2 escutcheon only. Model F1 FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC 1 Sprinkler Wrench Technlcai Data: Nominal "K" Factor Thread Temp. Rating Max. Bulb Orifice Size Model Ambient Color us Metric Sprinkler Cover Temp ½" (15mm) 5.6 80 ½"NPT F1FR 135°F/57°C 135°F/57°c 100°F/38°C Orange ½" (15mm) 5.6 80 ½"NPT F1 FR 1ss°F/68°c 135°F/57°C 100°Ft38°c Red ½" (15mm) 5.6 80 ½" NPT F1FR 11s°F/79°C 165°F/74°C 100°F/38°c Yellow ½" (15mm) 5.6 80 ½" NPT F1FR 200°F/93°C 165°F/74°C 150°F/6s0 c Green ('> For VdS only = 155°F/68°C Norbulb and 1/2" [12,7mm) adjustment. Model F1 FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technlcal Data: Nominal "K" Factor Thread Temp. Rating Max. Bulb Model Ambient Orifice us Metric Size Sprinkler Cover Temp Color 1/2" (15mm) 5.6 80 ½" NPT F1 FR56LL 200°F/93°C 165°F/74°C 150°F/65°c Green 'DuPont Registered Trademark 5. Sprinkler Approvals Identification Number(SIN) 1 RA1414 1,411', 6 RA1414 1 RA1414 1 RA1414 Sprinkler Approvals Identification Number(SIN) 1, 5 RA141 4 1 1/2" MAX. FACE OF FITTING 1-.. -··-·mTO FACE OF CEILING C~~~G MAX . .r·~1 ~=~li1~b~,=~ ~i'['.:i' :~~ COVER ADJUSTMENT j COVER PLATE ------~ ASSEMBLY J 5/l6 .. DIA. SPRINKLER ____J CONCEALED J /2" ADJUSTMENT 017F"001A Figure 1 Installation Aid A protective cap is included for use during installation. Important: The F1 FR56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1 FRXLH & F1 FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model F1 or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1 FR42LL, F1 FRXLH & F1 FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR42LL, F1 FRXLH & F1 FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1 FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 -24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LUCCP Concealed Sprinkler use the ½" orifice,½" NPT (R1/2), Model F1FR56 & F1FR56LL Pendent Sprinkler with a threaded Model CCP cup which is factory attached to the sprinklers. The Model F1 FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The Model F1 FR56LL Pendent is available only in a rating of 200°F (93°C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model CCP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the F1FR56 and 165°F (74°C) for the FIFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *D uPont Registered Trade Mark 6. 1 " • 1/2" REDUCING Tff OR ELBOW '-.... ··-··-··-----· -k=~=:" --------,--------,, :=~~~~ - --2 5/8" DIA. 2 5/16" 0 HOLE IN CEILING CUP 3/4" CONCEALED, 5/JS" ADJUSTMENT 011,00:rA Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 25/s" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKI ER The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1 FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. Temperature Ratings Sprinkler Max. Ambient Classification Temoerature Bulb Color oc OF Temp. Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green Hiah <1> 141 286 225°F /107°C\ Blue <1> Not available for recessed sprinklers. Escutcheon Data <1> <1> SIN RA1435 -cULus permits use with F1, F2 or FP escutcheons for "light hazard" only, while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR42LL, F1 FRXLH and Model F1 FR56, F1 FR56LL, F1 FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) •DuPont Registered Trademark 7. Finishes <1> Standard Finishes Sorin kier Escutcheon Cover olate<1> Bronze Brass Chrome Chrome Plated Chrome White Polvester Plated Coated <4x5xe) White Painted Soec ial Aoolicatlon Finishes Sorinkler Escutcheon Cover olate<1> Electroless Nickel Electroless Nickel Bright Brass PTFE/Teflon<11>)•<7> PTFE (Teflon<11>l' Briaht Brass<3l Briaht Brass Black Platinn Black Plated Black Plated Black Paint Black Paint<2xe, Black Paint Off White Off White<2X6l Off White Satin Chrome Chrome Dull Chrome Dull c1> Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. c2> cULus Listed only. <3> 200°F (93°C) maximum. c•> cULus listed "corrosion resistance" applies to SIN Numbers RA 1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. cs> FM Approvals finish as "Polyester coated" applies to SIN Number RA 1414, RA 1435 and RA 1425 in standard black or white. cs1 LPCB and VdSApprovedfinish applies only to RA 1425, RA 1414 and RA 1475. C1> cULus listed Corrosion Resistant Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) 9. Cover plate Model 10. Cover plate Thread size 11 . Cover plate Temperature 12. Cover plate Adjustment 13. Cover plate Finish Note: When Model F1 FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable! Product Description Model J11 2 and JL 112 series sprinklers are cULus Listed extended coverage spray sprinklers intended for installation in accordance with NFPA 13. The sprinklers also have cU- Lus Listed Specific Application Criteria for installation under concrete tee construction in accordance with the require- ments documented in this bulletin. Coverage areas up to 400 ft2 (37 m2) per sprinkler with a maximum spacing of up to 20 ft by 20 ft (6.1 m by 6.1 m) are permitted for both Light Hazard and Ordinary Hazard occupancies. Listed flows and pressures for each hazard classification and sprinkler spac- ing are provided in this bulletin. Model J112 and JL 112 se- ries sprinkler are cULus Listed as quick-response sprinklers for Light Hazard occupancies. When used in the Ordinary Hazard occupancies, Model J 112 and JL 112 series sprin- klers are cULus Listed as quick-response for spacings up to 14 ft by 14 ft ( 4.3 m by 4.3 m) and standard-response for other listed spacings up to 20 ft by 20 ft (6.1 m by 6.1 m). Model J112 Pendent and J1 12 Upright sprinklers use a glass bulb operating element and are cULus Listed as Corrosion Resistant Sprinklers when ordered with White Polyester, Black Polyester, or Electroless Nickel PTFE (ENT) finish. Model JL 112 Pendent and JL 112 Upright sprinklers use a fusible link operating element. Model J112 Pendent and Model JL 112 Pendent sprinklers are cULus Listed for use with the Model F2 and Model FP recessed escutch- eons, which provide up to½ inch (13 mm) of adjustment. In addition, for Ordinary Hazard occupancies, the Model J112 Pendent and Model JL 112 Pendent sprinklers are cULus Listed for use with the Model F1 recessed escutcheon that provides up to ¾ inch (19 mm) of adjustment. Application Model J 112 and JL 112 series sprinklers are intended for installation in Light Hazard and Ordinary Hazard occupan- cies in accordance with NFPA 13. The sprinklers must be installed in accordance with the requirements of NFPA 13 for extended coverage spray sprinklers and the require- ments identified in this bulletin. In addition to the installation requirements of NFPA 13, cULus Listed Specific Application Criteria for installation under concrete tee construction is provided in this bulletin. Model J112 and JL 112 Series Sprinkler Summary Model Orientation J112 Pendent JL112 Pendent J112 Upright JL11 2 Upright Bulletin 172 May 2019 Model J112 and JL 112 Sprinklers Extended Coverage Sprinklers for Light Hazard and Ordinary Hazard Model JL 112 Upright Model JL 112 Pendent F1/F2 Recessed Escutcheon Operating Element Glass Bulb Fusible Link Glass Bulb Fusible Link cULus Listed K11 .2 (160 metric) Model J 112 Upright Model J 112 Pendent FP Recessed Escutcheon Table A Sprinkler Identification Number (SIN) RA7216 R7216 RA7326 R7326 www.reliablesprinkler.com Model J112 Pendent Sprinkler SIN RA7216 Technical Specifications Style: Extended Coverage Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 11.2 (160 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Glass Bulb Cup: Bronze Alloy Frame: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Kick Spring: Steel Alloy Deflector: Brass Alloy Sprinkler Wrench Model J1 Model RJ (recessed) Finishes (See Table G) Sensitivity (See Table B) Temperature Ratings 155°F (68°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons F1 -3/4" (19mm) adjustment (Ordinary Hazard only) F2-1/2" (13mm) adjustment FP-1/2" (13mm) adjustment Listings and Approvals cULus Listed cULus Listed as Corrosion Resistant with White Polyester, Black Polyester, and ENT finish only _M_o_d_e_l_J_1_1_2_P_e_n_d_e_n_t_S_p_r_in_k_le_r_C_o_m_p_o_n_e_n_t_s _______________________ .§j.jijij- Wrench Flat Bulb Listed Design Criteria and Sensitivity Max. Spacing Light Hazard Ordinary Hazard Group 1 ft. X ft. (mxm) 12 X 12 (3.7 X 3.7) 14 X 14 (4.3 X 4.3) 16 X 16 (4.9 X 4.9) 18 X 18 (5.5 X 5.5) 20x 20 (6.1 X 6.1) QR = Quick-response SR = Standard-response Bulletin 172 May 2019 Flow gpm (Vm) 30 (114) QR 30 (114) QR 30 (114) QR 33 (125) QR 40 (152) QR Pressure Flow Pressure psi (bar) gpm (1/m) psi (bar) 7.2 (0.50) 30 (114) 7.2 (0.50) QR QR QR 7.2 (0.50) 30 (1 14) 7.2 (0.50) QR QR QR 7.2 (0.50) 39 (148) 12.1 (0.8) QR SR SR 8.7 (0.60) 49 (186) 19.1 (1.3) QR SR SR 12.8 (0.88) 60 (227) 28.7 (2.0) QR SR SR 3" (76mm) Table B Ordinary Hazard Group 2 Flow Pressure gpm (1/m) psi (bar) 39 (148) 12.1 (0.8) QR QR 39 (148) 12.1 (0.8) QR QR 51 (193) 20.7(1.4) SR SR 65 (246) 33.7 (2.3) SR SR 80 (303) 51 .0 (3.5) SR SR Page 2 of 7 www.reliablesprinkler.com Model JL 112 Pendent Sprinkler SIN R7216 Technical Specifications Style: Extended Coverage Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 11 .2 (160 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 fl. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Frame: Brass Alloy Levers: Brass Alloy Cap: Bronze Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Brass Alloy Strut: Copper Alloy Sprinkler Wrench Model J1 Model RJ (recessed) Finishes (See Table G) Sensitivity (See Table C) Temperature Rating* 165°F (74°C) 212°F (100°c) Recessed Escutcheons F1-3/4" (19mm) adjustment (Ordinary Hazard only) F2-1/2" (13mm) adjustment FP-1/2" (1 3mm) adjustment Listings and Approvals cULus Listed •c hrome and white polyester finish is supplied with white link regardless of temperature rating __ Mo_d_e_l_J_1_1_2_P_e_n_d_e_n_t_S_p_r_in_k_le_r_C_o_m....;p_o_n_e_n_t_s _______________________ .. ii•Mif.-lll Link Listed Design Criteria and Sensitivity Max. Spacing ft. X ft. (mxm) 12 X 12 (3.7 X 3.7) 14 X 14 (4.3 X 4.3) 16 X 16 (4.9 X 4.9) 18 X 18 (5.5 X 5.5) 20 x20 (6.1 X 6.1) QR = Quick-response SR = Standard-response Bulletin 172 May 2019 Light Hazard Flow Pressure gpm (Vm) psi (bar) 30 (114) 7.2 (0.50) QR QR 30 (114) 7.2 (0.50) QR QR 30 (114) 7.2 (0.50) QR QR 33 (125) 8.7 (0.60) QR QR 40 (152) 12.8 (0.88) QR QR L1-5/8" (42mm)J Ordinary Hazard Group 1 Flow Pressure gpm (1/m) psi (bar) 30(114) 7.2 (0.50) QR QR 30 (1 14) 7.2 (0.50) QR QR 39 (148) 12.1 (0.8) SR SR 49 (186) 19.1 (1.3) SR SR 60 (227) 28.7 (2.0) SR SR 3' (76mm) Table C Ordinary Hazard Group2 Flow Pressure gpm (Vm) psi (bar) 39 (148) 12.1 (0.8) QR QR 39 (148) 12.1 (0.8) QR QR 51 (193) 20.7 (1.4) SR SR 65 (246) 33.7 (2.3) SR SR 80 (303) 51.0 (3.5) SR SR Page 3 of 7 www.reliablesprinkler.com Model J112 Upright Sprinkler SIN RA7326 Technical Specifications Style: Extended Coverage Upright Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-factor: 11.2 (160 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Glass Bulb Cup: Bronze Alloy Frame: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Kick Spring: Steel Alloy Deflector: Brass Alloy Finishes (See Table G) Sensitivity (See Table D) Temperature Rating 155°F (6a0 c) 200°F (93°G) 2as°F (141 °C) Sprinkler Wrench Model J1 Listings and Approvals cULus Listed cULus Listed as Corrosion Resistant with White Polyester, Black Polyester, and ENT finish only _M_o_d_e_l_J_1_1_2_U_p_r_ig'-h_t_S_p_r_in_k_l_e_r_C_o_m __ p_o_n_e_n_ts ________________________ i/-/iiif- Wrench Flat Bulb 1-5/8' (41mm) Listed Design Criteria and Sensitivity Max. Spacing Light Hazard Ordinary Hazard Group 1 ft. X ft. (mxm) 12 X 12 (3.7 X 3.7) 14 X 14 (4.3 X 4.3) 16 X 16 (4.9 X 4.9) 18 X 18 (5.5 X 5.5) 20x 20 (6.1 X 6.1) QR = Quick-response SR = Standard-response Bulletin 172 May 2019 Flow gpm (Vm) 30 (114) QR 30 (114) QR 30 (114) QR 33 (125) QR 40 {152) QR Pressure Flow Pressure psi (bar) gpm (Vm) psi (bar) 7.2 (0.50) 30 (114) 7.2 (0.50) QR QR QR 7.2 (0.50) 30 (114) 7.2 (0.50) QR QR QR 7.2 (0.50) 39 (148) 12.1 (0.8) QR SR SR 8.7 (0.60) 49 (186) 19.1 (1.3) QR SR SR 12.8 (0.88) 60 (227) 28.7 (2.0) QR SR SR iTirF'Frr: 2-13/16' (71mm) Table D Ordinary Hazard Group2 Flow Pressure gpm (1/m) psi (bar) 39 (148) 12.1 (0.8) QR QR 39 (148) 12.1 (0.8) QR QR 51 (193) 20.7(1.4) SR SR 65 (246) 33.7 (2.3) SR SR 80 (303) 51.0 (3.5) SR SR Page 4 of 7 www.reliablesprinkler.com Model JL 112 Upright Sprinkler SIN R7326 Technical Specifications Style: Extended Coverage Upright Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-factor: 11.2 (160 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Frame: Brass Alloy Levers: Brass Alloy Strut: Brass Alloy Cap: Bronze Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Brass Alloy Finishes (See Table G) Sensitivity (See Table E) Temperature Rating• 165°F (74°C) 212°F (100°C) Sprinkler Wrench Model J1 Listings and Approvals cULus Listed *Chrome and white polyester finish is supplied with white link regardless of temperature rating _M_o_d_e_l_J_L_1_12_U_p_r_ig_h_t_S_p_r_in_k_l_e_r_C_o_m_p_o_ne_n_t_s ______________________ ~-i/-jijji- Wrench Flat Link --1-5/8' (41mm) Listed Design Criteria and Sensitivity Max. Spacing Light Hazard Ordinary Hazard Group 1 ft. X ft. (mxm) 12 X 12 (3.7 X 3.7) 14 X 14 (4.3 X 4.3) 16 X 16 (4.9 X 4.9) 18 X 18 (5.5 X 5.5) 20x 20 (6.1 X 6.1) QR = Quick-response SR = Standard-response Bulletin 172 May 2019 Flow gpm (Vm) 30(114) QR 30 (114) QR 30 (114) QR 33 (125) QR 40 (152) OR Pressure Flow Pressure psi (bar) gpm (1/m) psi (bar) 7.2 (0.50) 30 (114) 7.2 (0.50) QR QR QR 7.2 (0.50) 30(114) 7.2 (0.50) QR QR QR 7.2 (0.50) 39 (148) 12.1 (0.8) QR SR SR 8.7 (0.60) 49 (1 86) 19.1 (1.3) QR SR SR 12.8 (0.88) 60 (227) 28.7 (2.0) OR SR SR i . . • . 2-13/16' (71mm) Table E Ordinary Hazard Group2 Flow Pressure gpm (1/m) psi (bar) 39 (148) 12.1 (0.8) QR QR 39 (148) 12.1 (0.8) QR OR 51 (193) 20.7 (1.4) SR SR 65 (246) 33.7 (2.3) SR SR 80 (303) 51.0 (3.5) SR SR Page 5 of 7 www.reliablesprinkler.com Model J112 and JL 112 Specific Application Criteria for Use Under Concrete Tee Construction cULus Listed The Model J112 and JL 11 2 pendent and upright sprinklers are cULus Listed for installation under concrete tee construction in ac- cordance with the following specific application criteria: • Max. Tee Depth: 2'-6" (0.8m) • Max. Tee Stem Spacing: 7'-6" (2.3m) • Min. Tee Stem Spacing: 3'-O" (0.9m) • Max. Tee Length: 32'-O" (9.8m) or baffles not less than the depth of the tees must be installed so that the longitudinal space between baffles does not exceed 32ft (9.8m) in length. • Max. Deflector distance below Tee: 1" (25mm) • Comply with obstructions to the Sprinkler Discharge Pattern Development requirements of the NFPA13 where deflector is lo- cated above bottom of tee. Application and Installation for Use Under Concrete Tee Figure 5 Model FP Escutcheon Installation Dimensions 2-5/8' DIA. (67mm) -t--+------+-< Hole In Celllng 2.S/16' DIA. --t,J--t (59mm)Cup --3-3/16' (81mm) v t::~=~:v lL..Y !• ·····················T······················~ 1" (25mm) max. J ! 7'-6" (2.3m) max. ! 3'-0' (0.9m) min. Figure 6 1' (25mm) +/-1/4' (6mm) 1-3/8' (35mm) +/-1/4' (6mm) Model F1/F2 Escutcheon Installation Dimensions 1-15/16"DIA. (491ml) 2-318' (60mm) DIA . Hole In Celling 2-13/16"(71mm) Figure 7 Fl: 1/Z' (12mm) +/-3/8' (10mm) t--+,"'T'Tm-,, F2: 3/8' (10mm) +/. 1/4' (6mm) F1:2'(51mm) •/-3/8'(10mm) F2: 2· 1/8' (54mm) +/· 1/4' (6mm) Note: The Model FP, F1 , or F2 may be used for ordinary hazard occupancies. For light hazard occupancies, the Model FP or F2 recessed escutcheon must be used. Model J112 and JL 112 sprinklers with Model F1 recessed escutcheon are not listed for use in light hazard occupancies. Bulletin 172 May 2019 Page 6 of 7 www.reliablesprinkler.com