HomeMy WebLinkAbout3038 VILLETA AVE; ; FPR2017-0257; PermitPERMIT REPORT C cityof Carlsbad Fire Permit Print Date: 03/16/2022 Permit No: FPR2017-0257 Job Address: 3038 VILLETA AVE, CARLSBAD, CA Status: Closed -Finaled Permit Type: FIRE-Construction Residential Work Class: Single Family Fire Sprinkl, Parcel#: Track#: Applied: 06/22/2017 Valuation: $0.00 Lot#: Issued: 08/22/2017 Occupancy Group: Project#: DEV2016-0060 Fina led Close Out: 03/16/2022 #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Inspector: Plan Check#: Final Inspection: Project Title: CYPRESS AT THE PRESERVE Description: REVISED PLANS FOR CYPRESS AT THE PRESERVE/ MODEL/ PLAN 1 / LOT 10-SPRINKLER FEE FIRE NFPA 13D Single Family System (lnsp/Bldg) FIRE NFPA 13D Single Family System (Plan Review) FIRE Plan Review Per Hour -Office Hours Total Fees: $496.00 Total Payments To Date: Fire Department $496.00 FPContractor: NP MECHANICAL INC PO BOX 309 CORONA, CA 92878-0309 (951) 667-4220 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov AMOUNT $121.00 $239.00 $136.00 $0.00 Page 1 of 1 Job Name Building Location System Contract Data File MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951 -667-4220 CYPRESS AT THE PRESERVE PLAN 1 CALC AREA 1 1 PLAN1 CA1 16X16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical CYPRESS AT THE PRESERVE HYDRAULIC DESIGN INFORMATION SHEET Name -CYPRESS AT THE PRESERVE Location -CALC AREA 1 Building -PLAN 1 Date -5/25/17 System No . -1 Contr act No . - Drawing No . -1 Contractor -NP MECHANICAL Calculated By -MG Construction: (X) Combustible OCCUPANCY -LIGHT HAZARD ( ) Non-Combustible Ceiling Height 9 '-0" s y s T E M D E s I G N Type of Cal cul ation : ( )NFPA 13 Residential Number of Sprinklers Flowing: ( )1 (X)2 ( ) Other ( ) Specific Ruling Made by Listed Flow at Start Point -13 Listed Pres . at Start Point -7 MAXIMUM LISTED SPACING 16 x 16 -5 Gpm Psi )NFPA 13R (X)NFPA 13D ) 4 ( ) Date System Type (X) Wet ( ) Dry ( ) Deluge ( ) PreAction Sprinkler or Nozzle Domestic Flow Added Additional Flow Added El evation at Highest Outlet - Note: Gpm Gpm Feet Make RELIABLE Model RFC49 Size 7/16 K-Factor 4 .9 Temperature Rating 165 Calculation Summary Gpm Required 26 .003 C-Factor Used: Psi Required 45 .151 Overhead 150 At BR Underground 150 w A T E R s p p L y Water Flow Test: Date of Test Time of Test Static (Psi) - Residual (Psi) - Flow (Gpm) - Elevation - Location : Pump Rated @ Psi 94 Elev. 66 Other 3750 114 Dat a : Cap. Tank or Reservoir : Cap. Elev. Well Proof Flow Gpm Source of I nformation: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page Date 1 5/25/17 • Water Supply Curve C NP Mechanical CYPRESSATTHEPRESERVE City Water Supply: C1 -Static Pressure . 84.6 C2 -Residual Pressure: 59.4 C2 -Residual Flow 3750 150 140 130 p 120 R 110 E 100 S 90 ,:;-,- S 80 -oz U 70 D3 R 60 E 50 40 30 20 10 1 UT 400 800 1200 1600 Page 2 Date 5/25/17 Demand: 2000 2400 2800 3200 FLOW ( N " 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 D1 -Elevation D2 -System Flow D2 -System Pressure Hose ( Demand ) D3 -System Demand Safety Margin 3600 : 12.127 : 26.003 : 73.935 :5 : 31.003 : 10.661 C2 " Fittings Used Summary NP Mechanical CYPRESS AT THE PRESERVE Fitting Legend Abbrev. Name F NFPA 13 45' Elbow Fsp Flow Switch Potter VSR N* CPVC 90'EII Harvel-Spears o· CPVC Tee -Branch R* CPVC Coupling Tee -Run s NFPA 13 Swing Check T NFPA 13 90' Flowthru Tee Units Summary Diameter Units Length Units Flow Units Pressure Units ½ ¾ 1 1¼ 1½ 2 1 1 1 1 2 2 Fitting generates a Fixed Loss Based on Flow 3 1 0 3 Inches Feet 7 3 1 0 4 7 8 5 6 1 1 5 7 5 6 US Gallons per Minute Pounds per Square Inch 9 11 8 10 1 1 9 11 8 10 2½ 3 3 3 12 13 12 15 2 2 14 16 12 15 Note: Fitting Legend provides equivalent pipe lengths tor fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors 3½ 3 0 0 0 19 17 of 120 except as noted with*. The fittings marked with a• show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values tor fittings not marked with a * will be adjusted in the calculation tor CFactors of other than 120 and diameters other than Sched 40 per NFPA. 4 5 6 8 4 5 7 9 0 0 0 0 0 0 0 0 0 0 0 0 22 27 32 45 20 25 30 35 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date 5/25/17 10 12 14 16 18 20 24 11 13 17 19 21 24 28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 55 65 50 60 71 81 91 101 121 11 Pressure / Flow Summary -STANDARD ~ NP Mechanical Page 4 CYPRESS AT THE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Re . H1 9.0 4.9 7.04 na 13.0 0.05 256 7.0 H2 9.0 4.9 7.04 na 13.0 0.05 256 7.039 H3 19.0 12.97 na H4 19.0 11.24 na H5 19.0 10.33 na 1 10.0 8.45 na D1 10.0 6.99 na D2 10.0 6.98 na 2 10.0 8.5 na 3 10.0 9.31 na 4 20.0 9.4 na D5 20.0 9.9 na 5 20.0 9.9 na D4 20.0 10.8 na 6 20.0 10.8 na D3 20.0 12.53 na 7 20.0 12.53 na 8 20.0 13.53 na 10 20.0 14.74 na 11 20.0 9.94 na 12 10.0 25.11 na 13 10.0 30.9 na 14 10.0 32.88 na TR 10.0 35.75 na BR 2.0 45.15 na 5.0 X 2.0 46.22 na EL -3.0 48.81 na M1 -3.0 54.3 na M2 -3.0 58.52 na CM -3.0 67.0 na 100 -3.0 67.0 na 101 -3.0 67.0 na 102 -3.0 67.0 na 103 -3.0 67.0 na 104 -3.0 67.0 na FT -19.0 73.94 na The maximum velocity is 13.9 and it occurs in the pipe between nodes 3 and 4 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Dia. "C" Fitting or Hyd. Ref. Point Qa Qt Pf/Ft Eqv. Ln. H1 13.00 0.874 0 3.0 to 150.0 0.0 01 13.0 0.0945 0.0 0.0 13.00 H2 13.00 0.874 0 3.0 to 150.0 0.0 02 13.0 0.0945 0.0 0.0 13.00 H3 0.0 0.874 N 7.0 to 150.0 0.0 03 0.0 0.0 0.0 0.0 0.0 H4 0.0 0.874 0 3.0 to 150.0 0.0 04 0.0 0.0 0.0 0.0 0.0 H5 0.0 0.874 N 7.0 to 150.0 0.0 05 0.0 0.0 0.0 0.0 0.0 -13.34 0.874 R 1.0 to 150.0 0.0 01 -13.34 -0.0991 0.0 01 13.00 0.874 2N 14.0 to 150.0 R 1.0 02 -0.34 -0.0001 0.0 02 13.00 0.874 0 3.0 to 150.0 0.0 2 12.66 0.0899 0.0 2 0.0 0.874 0 3.0 to 150.0 0.0 3 12.66 0.0899 0.0 3 -26.00 0.874 0 3.0 to 150.0 0.0 1 -13.34 -0.0990 0.0 0.0 -13.34 3 26.00 0.874 0 3.0 to 150.0 0.0 4 26.0 0.3405 0.0 4 -15.28 0.874 R 1.0 to 150.0 0.0 5 10.72 0.0661 0.0 Pipe Ftng's Total 1.000 3.000 4.000 1.000 3.000 4.000 1.000 7.000 8.000 1.000 3.000 4.000 1.000 7.000 8.000 13.750 1.000 14.750 12.333 15.000 27.333 13.917 3.000 16.917 5.917 3.000 8.917 5.667 3.000 8.667 10.000 3.000 13.000 6.583 1.000 7.583 Pt Pe Pf 7.042 -0.433 0.378 6.987 7.039 -0.433 0.378 6.984 12.968 -0.433 0.0 12.535 11.238 -0.433 0.0 10.805 10.335 -0.433 0.0 9.902 8.448 0.0 -1.461 6.987 0.0 -0.003 6.984 0.0 1.520 8.504 0.0 0.802 9.306 0.0 -0.858 8.448 9.306 -4.331 4.426 9.401 0.0 0.501 Pt Pv Pn Page 5 Date 5/25/17 ******* Notes ****** K Factor= 4.90 Vel = 6.95 K Factor = 4.92 K Factor= 4.90 Vel = 6.95 K Factor= 4.92 Vel = 0 K Factor= 0 Vel = 0 K Factor= 0 Vel = 0 K Factor = 0 Vel = 7.13 Vel = 0.18 Vel = 6.77 Vel = 6.77 Vel = 7.13 K Factor= -4.59 Vel = 13.90 Vel = 5.73 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Dia. "C" Fitting or Hyd. Ref. Point Qa Qt Pf/Ft Eqv. Ln. 0.0 10.72 D5 0.0 0.874 0 3.0 to 150.0 0.0 5 0.0 0.0 0.0 5 10.72 0.874 N 7.0 to 150.0 R 1.0 6 10.72 0.0661 0.0 0.0 10.72 D4 0.0 0.874 0 3.0 to 150.0 0.0 6 0.0 0.0 0.0 6 10.72 0.874 3R 3.0 to 150.0 0.0 7 10.72 0.0661 0.0 0.0 10.72 D3 0.0 0.874 20 6.0 to 150.0 0.0 7 0.0 0.0 0.0 7 10.72 0.874 N 7.0 to 150.0 0.0 8 10.72 0.0661 0.0 8 0.0 0.874 0 3.0 to 150.0 0.0 10 10.72 0.0661 0.0 10 -26.00 0.874 3R 3.0 to 150.0 0 3.0 11 -15.28 -0.1273 0.0 11 0.0 0.874 R 1.0 to 150.0 0.0 4 -15.28 -0.1273 0.0 0.0 -15.28 10 26.00 0.874 2N 14.0 to 150.0 0.0 12 26.0 0.3404 0.0 12 0.0 0.874 N 7.0 to 150.0 0.0 13 26.0 0 .3404 0.0 13 0.0 0.874 0 3.0 to 150.0 0.0 14 26.0 0.3405 0.0 14 0.0 0.874 N 7.0 to 150.0 0.0 TR 26.0 0.3404 0.0 0.0 Pipe Ftng's Total 0.500 3.000 3.500 5.667 8.000 13.667 3.583 3.000 6.583 23.167 3.000 26.167 6.250 6.000 12.250 8.000 7.000 15.000 15.333 3.000 18.333 31.667 6.000 37.667 3.250 1.000 4.250 3.750 14.000 17.750 10.000 7.000 17.000 2.833 3.000 5.833 1.417 7.000 8.417 Pt Pe Pf 9.902 9.902 0.0 0.0 9.902 0.0 0.903 10.805 10.805 0.0 0.0 10.805 0.0 1.730 12.535 12.535 0.0 0.0 12.535 0.0 0.991 13.526 0.0 1.212 14.738 0.0 -4.796 9.942 0.0 -0.541 9.401 14.738 4.331 6.042 25.111 0.0 5.787 30.898 0.0 1.986 32.884 0.0 2.865 Pt Pv Pn Page 6 Date 5/25/17 ******* Notes ****** K Factor = 3.41 Vel = 0 Vel = 5.73 K Factor = 3.26 Vel = 0 Vel = 5.73 K Factor= 3.03 Vel = 0 Vel = 5.73 Vel = 5.73 Vel = 8.17 Vel = 8.17 K Factor= -4.98 Vel = 13.90 Vel = 13.90 Vel = 13.90 Vel = 13.90 Computer Programs by Hydratec Inc. Route 11 1 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point TR to BR BR to X X to EL EL to M1 M1 to M2 M2 to CM CM to 100 100 to 101 100 to 105 101 to 102 102 to 103 103 to 104 104 to 105 104 to CM Qa Qt 26.00 26.00 26.0 5.00 31.0 0.0 31.0 0.0 31.0 0.0 31.0 0.0 31.0 -14.00 17.0 0.87 17.87 0.0 17.87 -0.87 -0.87 0.0 -0.87 17.87 17.87 -31 .00 -13.13 0.0 -13.13 14.00 0.87 0.0 0.87 -14.00 -14.0 Dia. "C .. Pf/Ft 1.101 150.0 0.1106 1.101 150.0 0.1531 1.244 150.0 0.0842 1.244 150.0 0.0845 1.025 150.0 0.2170 0.995 150.0 0.2506 7.98 150.0 0.0 7.98 150.0 0.0 7.98 150.0 0.0 11 .65 150.0 0.0 11 .65 150.0 0.0 7.98 150.0 0.0 11.65 150.0 0.0 7.98 150.0 0.0 Fitting or Eqv. Ln. 2R 2.0 s 9.563 Fsp 0.0 N 7.0 0 5.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 T 5.841 0.0 0.0 3F 40.774 T 52.855 0.0 T 52.855 0.0 0.0 2T 105.71 0.0 0.0 F 17.441 T 80.498 0.0 F 17.441 T 80.498 0.0 T 52.855 0.0 0.0 T 80.498 0.0 0.0 T 52.855 0.0 0.0 Pipe Ftng's Total 8.000 18.562 26.562 2.000 5.000 7.000 5.000 0.0 5.000 65.000 0.0 65.000 1.000 0.0 1.000 28.000 5.841 33.841 324.000 93.629 417.629 295.000 52.855 347.855 381.000 105.710 486.710 175.000 97.939 272.939 532.000 97.939 629.939 542.000 52.855 594.855 207.000 80.498 287.498 542.000 52.855 594.855 Computer Programs by Hydratec Inc. Route 111 Pt Pe Pf 35.749 35.749 6.465 2.937 45.151 0.0 1.072 46.223 2.166 0.421 48.810 0.0 5.491 54.301 4.000 0.217 58.518 0.0 8.482 67.000 0.0 0.002 67.002 0.0 0.001 67.003 67.002 -1.299 -0.001 65.702 67.003 0.0 0.0 67.003 0.0 0.0 67.003 0.0 -0.001 67.002 -1.299 -0.001 65.702 67.002 0.0 -0.002 Pt Pv Pn Page 7 Date 5/25/17 ******* Notes ****** K Factor = 4.35 * * Fixed Loss = 3 Vel = 8.76 Oa=5 Vel = 10.45 Vel = 8.18 Vel= 8.18 * * Fixed Loss = 4 Vel = 12.05 Vel = 12.79 Vel = 0.11 Vel = 0.11 K Factor= 2.18 Vel = 0.01 K Factor = -0.11 Vel = 0.05 Vel = 0.04 Vel = 0.08 Vel = 0 K Factor= 0.11 Vel = 0.09 Windham N.H. USA 03087 ~inal Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point 102 to FT Qa Qt 0.0 -14.00 31.00 31.0 0.0 31.00 Dia. "Cu Pf/Ft 11 .65 150.0 0.0 Fitting or Eqv. Ln. 3T 241.494 0.0 0.0 Pipe Ftng's Total 1439.000 241.494 1680.494 Pt Pe Pf 67.000 67.003 6.930 0.002 73.935 Pt Pv Pn Page 8 Date 5/25/17 ******* Notes ****** K Factor= -1.71 Vel = 0.09 K Factor = 3.61 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Job Name Building Location System Contract Data File MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951-667-4220 CYPRESS AT THE PRESERVE PLAN 1 CALC AREA 2 1 PLAN1 CA2 20X20.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical CYPRESS AT THE PRESERVE HYDRAULIC DESIGN INFORMATION SHEET Name -CYPRESS AT THE PRESERVE Location -CALC AREA 2 Building -PLAN 1 Date -5/25/17 System No . -1 Contract No . - Drawing No . -1 Contractor -NP MECHANICAL Calculated By -MG Construction: (X) Combustible OCCUPANCY -LIGHT HAZARD ( ) Non-Combustible Ceiling Height 9 '-0 " s y s T E M D E s I G N Type of Calculation : ( )NFPA 13 Residential Number of Sprinklers Flowing: (X) 1 ( ) 2 ( ) Other ( )Specific Ruling Made by Listed Flow at Start Point -20 Gpm Listed Pres . at Start Point -16 .7 Psi MAXIMUM LISTED SPACING 20 x 20 Domestic Flow Added -5 )NFPA 13R (X)NFPA 13D ) 4 ( ) Date System Type (X ) Wet () Dry ( ) Deluge ( ) PreAction Sprinkler or Nozzle Additional Flow Added Elevation at Highest Outlet - Note: Gpm Gpm Feet Make RELIABLE Model RFC49 Size 7/16 K-Factor 4.9 Temperature Rating 165 Calculation Summary Gpm Required 20 .024 C-Factor Used: Psi Required 46.390 Overhead 150 At BR Underground 150 w A T E R s p p L y Water Flow Test: Date of Test Time of Test Static (Psi) - Residual (Psi) - Flow (Gpm ) - Elevation - Location: Pump Rated @ Psi 94 Elev. 66 Other 3750 114 Data : Cap. Tank or Reservoir : Cap. Elev. Well Proof Flow Gpm Source of Information : Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page Date 1 5/25/17 Water Supply Curve C NP Mechanical CYPRESS AT THE PRESERVE City Water Supply: C1 -Static Pressure . 84.6 C2 -Residual Pressure: 59.4 C2 -Residual Flow 3750 150 140 130 p 120 R 110 E 100 S 90 -c;T S 80 02 U 70 R 60 03 E 50 40 30 20 1 10 0 1 400 800 1200 1600 Page 2 Date 5/25/17 Demand: 2000 2400 2800 3200 FLOW ( N " 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 01 -Elevation 02 -System Flow 02 -System Pressure Hose ( Demand ) 03 -System Demand Safety Margin 3600 : 16.458 : 20.024 : 70.040 :5 : 25.024 : 14.557 C2 Fittings Used Summary NP Mechanical CYPRESS AT THE PRESERVE Fitting Legend Abbrev. Name F NFPA 13 45' Elbow Fsp Flow Switch Potter VSR N* CPVC 90'EII Harvel-Spears o · CPVC Tee · Branch R* CPVC Coupling Tee -Run s NFPA 13 Swing Check T NFPA 13 90' Flow thru Tee Units Summary Diameter Units Length Units Flow Units Pressure Units ½ ¾ 1 1¼ 1½ 2 1 1 1 1 2 2 Fitting generates a Fixed Loss Based on Flow 3 1 0 3 Inches Feet 7 3 1 0 4 7 8 5 6 1 1 5 7 5 6 US Gallons per Minute Pounds per Square Inch 9 11 8 10 1 1 9 11 8 10 2½ 3 3 3 12 13 12 15 2 2 14 16 12 15 Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CF actors 3½ 3 0 0 0 19 17 of 120 except as noted with*. The fittings marked with a* show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CF actors of other than 120 and diameters other than Sched 40 per NFPA. 4 5 6 8 4 5 7 9 0 0 0 0 0 0 0 0 0 0 0 0 22 27 32 45 20 25 30 35 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date 5/25/17 10 12 14 16 18 20 24 11 13 17 19 21 24 28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 55 65 50 60 71 81 91 101 121 Pressure/ Flow Summary -STANDARD NP Mechanical Page 4 CYPRESS AT THE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. H1 9.0 26.86 na H2 9.0 26.86 na H3 19.0 4.9 16.7 na 20.02 0.05 400 16.7 H4 19.0 21.82 na H5 19.0 22.28 na 1 10.0 26.43 na D1 10.0 26.43 na D2 10.0 26.43 na 2 10.0 26.43 na 3 10.0 26.43 na 4 20.0 22.1 na D5 20.0 21.85 na 5 20.0 21.85 na D4 20.0 21.39 na 6 20.0 21.39 na D3 20.0 17.95 na 7 20.0 20.52 na 8 20.0 21.86 na 10 20.0 23.5 na 11 20.0 22.24 na 12 10.0 31.55 na 13 10.0 35.12 na 14 10.0 36.35 na TR 10.0 38.11 na BR 2.0 46.39 na 5.0 X 2.0 47.11 na EL -3.0 49.56 na M1 -3.0 53.25 na M2 -3.0 57.4 na CM -3.0 63.11 na 100 -3.0 63.11 na 101 -3.0 63.11 na 102 -3.0 63.11 na 103 -3.0 63.11 na 104 -3.0 63.11 na FT -19.0 70.04 na The maximum velocity is 10.71 and it occurs in the pipe between nodes H3 and D3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Dia. "C" Fitting or Hyd. Ref. Point Oa Qt Pf/Ft Eqv. Ln. H1 0.0 0.874 0 3.0 to 150.0 0.0 D1 0.0 0.0 0.0 0.0 0.0 H2 0.0 0.874 0 3.0 to 150.0 0.0 D2 0.0 0.0 0.0 0.0 0.0 H3 20.02 0.874 N 7.0 to 150.0 0.0 D3 20.02 0.2099 0.0 0.0 20.02 H4 0.0 0.874 0 3.0 to 150.0 0.0 D4 0.0 -0.0002 0.0 0.0 0.0 H5 0.0 0.874 N 7.0 to 150.0 0.0 D5 0.0 0.0 0.0 0.0 0.0 0.0 0.874 R 1.0 to 150.0 0.0 D1 0.0 0.0 0.0 D1 0.0 0.874 2N 14.0 to 150.0 R 1.0 D2 0.0 0.0 0.0 D2 0.0 0.874 0 3.0 to 150.0 0.0 2 0.0 0.0 0.0 2 0.0 0.874 0 3.0 to 150.0 0.0 3 0.0 0.0 0.0 3 0.0 0.874 0 3.0 to 150.0 0.0 1 0.0 0.0 0.0 0.0 0.0 3 0.0 0.874 0 3.0 to 150.0 0.0 4 0.0 0.0 0.0 4 -7.41 0.874 R 1.0 to 150.0 0.0 5 -7.41 -0.0334 0.0 Pipe Ftng's Total 1.000 3.000 4.000 1.000 3.000 4.000 1.000 7.000 8.000 1.000 3.000 4.000 1.000 7.000 8.000 13.750 1.000 14.750 12.333 15.000 27.333 13.917 3.000 16.917 5.917 3.000 8.917 5.667 3.000 8.667 10.000 3.000 13.000 6.583 1.000 7.583 Pt Pe Pf 26.863 -0.433 0.0 26.430 26.863 -0.433 0.0 26.430 16.700 -0.433 1.679 17.946 21.824 -0.433 -0.001 21.390 22.279 -0.433 0.0 21.846 26.430 0.0 0.0 26.430 0.0 0.0 26.430 0.0 0.0 26.430 0.0 0.0 26.430 0.0 0.0 26.430 26.430 -4.331 0.0 22.099 0.0 -0.253 Pt Pv Pn Page 5 Date 5/25/17 ******* Notes ****** Vel = 0 K Factor= 0 Vel = 0 K Factor= 0 K Factor = 4.90 Vel = 10.71 K Factor= 4.73 Vel = 0 K Factor = 0 Vel = 0 K Factor = 0 Vel = 0 Vel = 0 Vel = 0 Vel = 0 Vel = 0 K Factor= 0 Vel = 0 Vel = 3.96 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Dia. ..C" Fitting or Hyd. Ref. Point Qa Qt Pf/Ft Eqv. Ln. 0.0 -7.41 D5 0.0 0.874 0 3.0 to 150.0 0.0 5 0.0 0.0 0.0 5 -7.41 0.874 N 7.0 to 150.0 R 1.0 6 -7.41 -0.0334 0.0 0.0 -7.41 D4 0.0 0.874 0 3.0 to 150.0 0.0 6 0.0 0.0 0.0 6 -7.41 0.874 3R 3.0 to 150.0 0.0 7 -7.41 -0.0333 0.0 0.0 -7.41 D3 20.02 0.874 20 6.0 to 150.0 0.0 7 20.02 0.2100 0.0 7 -7.40 0.874 N 7.0 to 150.0 0.0 8 12.62 0.0893 0.0 8 0.0 0.874 0 3.0 to 150.0 0.0 10 12.62 0.0893 0.0 10 -20.03 0.874 3R 3.0 to 150.0 0 3.0 11 -7.41 -0.0333 0.0 11 0.0 0.874 R 1.0 to 150.0 0.0 4 -7.41 -0.0332 0.0 0.0 -7.41 10 20.02 0.874 2N 14.0 to 150.0 0.0 12 20.02 0.2100 0.0 12 0.0 0.874 N 7.0 to 150.0 0.0 13 20.02 0.2099 0.0 13 0.0 0.874 0 3.0 to 150.0 0.0 14 20.02 0.2100 0.0 14 0.0 0.874 N 7.0 to 150.0 0.0 TR 20.02 0.2099 0.0 0.0 Pipe Ftng's Total 0.500 3.000 3.500 5.667 8.000 13.667 3.583 3.000 6.583 23.167 3.000 26.167 6.250 6.000 12.250 8.000 7.000 15.000 15.333 3.000 18.333 31.667 6.000 37.667 3.250 1.000 4.250 3.750 14.000 17.750 10.000 7.000 17.000 2.833 3.000 5.833 1.417 7.000 8.417 Pt Pe Pf 21.846 21.846 0.0 0.0 21.846 0.0 -0.456 21 .390 21.390 0.0 0.0 21.390 0.0 -0.872 20.518 17.946 0.0 2.572 20.518 0.0 1.340 21.858 0.0 1.638 23.496 0.0 -1.256 22.240 0.0 -0.141 22.099 23.496 4.331 3.727 31.554 0.0 3.568 35.122 0.0 1.225 36.347 0.0 1.767 Pt Pv Pn Page 6 Date 5/25/17 ******* Notes ****** K Factor = -1 .59 Vel = 0 Vel = 3.96 K Factor = -1.60 Vel = 0 Vel = 3.96 K Factor = -1.64 Vel = 10.71 Vel = 6.75 Vel = 6.75 Vel = 3.96 Vel = 3.96 K Factor = -1 .58 Vel = 10.71 Vel= 10.71 Vel = 10.71 Vel = 10.71 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point TR to BR BR to X X to EL EL to M1 M1 to M2 M2 to CM CM to 100 100 to 101 100 to 105 101 to 102 102 to 103 103 to 104 104 to 105 104 to CM Qa Qt 20.02 20.02 20.02 5.00 25.02 0.0 25.02 0.0 25.02 0.0 25.02 0.0 25.02 -11 .30 13.72 0.70 14.42 0.0 14.42 -0.70 -0.7 0.0 -0.70 14.42 14.42 -25.02 -10.6 0.0 -10.6 11.30 0.7 0.0 0.70 -11 .30 -11.3 Dia. "C" Pf/Ft 1.101 150.0 0.0682 1.101 150.0 0.1030 1.244 150.0 0.0568 1.244 150.0 0.0568 1.025 150.0 0.1460 0.995 150.0 0.1686 7.98 150.0 0.0 7.98 150.0 0.0 7.98 150.0 0.0 11 .65 150.0 0.0 11 .65 150.0 0.0 7.98 150.0 0.0 11 .65 150.0 0.0 7.98 150.0 0.0 Fitting or Eqv. Ln. 2R 2.0 s 9.563 Fsp 0.0 N 7.0 0 5.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 T 5.841 0.0 0.0 3F 40.774 T 52.855 0.0 T 52.855 0.0 0.0 2T 105.71 0.0 0.0 F 17.441 T 80.498 0.0 F 17.441 T 80.498 0.0 T 52.855 0.0 0.0 T 80.498 0.0 0.0 T 52.855 0.0 0.0 Pipe Ftng's Total 8.000 18.562 26.562 2.000 5.000 7.000 5.000 0.0 5.000 65.000 0.0 65.000 1.000 0.0 1.000 28.000 5.841 33.841 324.000 93.629 417.629 295.000 52.855 347.855 381.000 105.710 486.710 175.000 97.939 272.939 532.000 97.939 629.939 542.000 52.855 594.855 207.000 80.498 287.498 542.000 52.855 594.855 Computer Programs by Hydratec Inc. Route 111 Pt Pe Pf 38.114 38.114 6.465 1.811 46.390 0.0 0.721 47.111 2.166 0.284 49.561 0.0 3.693 53.254 4.000 0.146 57.400 0.0 5.707 63.1 07 0.0 0.001 63.108 0.0 0.001 63.109 63.108 -1.299 0.0 61.809 63.109 0.0 0.0 63.109 0.0 0.0 63.109 0.0 -0.001 63.108 -1.299 0.0 61.809 63.108 0.0 -0.001 Pt Pv Pn Page 7 Date 5/25/17 ******* Notes K Factor= 3.24 * * Fixed Loss = 3 Vel = 6.75 Oa=5 Vel = 8.43 Vel = 6.60 Vel= 6.60 * * Fixed Loss = 4 Vel = 9.73 Vel = 10.32 Vel = 0.09 Vel = 0.09 K Factor= 1.82 Vel = 0 K Factor= -0.09 Vel= 0.04 Vel = 0.03 Vel = 0.07 Vel = 0 K Factor= 0.09 Vel = 0.07 Windham N.H. USA 03087 .. Final Calculations -Hazen-Williams NP Mechanical CYPRESSATTHEPRESERVE Dia. "C" Fitting or Hyd. Ref. Point Qa Qt Pf/Ft Eqv. Ln. 0.0 -1 1.30 102 25.02 11 .65 3T 241.494 to 150.0 0.0 FT 25.02 0.0 0.0 0.0 25.02 Pipe Ftng's Total 1439.000 241.494 1680.494 Pt Pe Pf 63.107 63.109 6.930 0.001 70.040 Pt Pv Pn Page 8 Date 5/25/17 ******* Notes ****** K Factor = -1 .42 Vel = 0.08 K Factor= 2.99 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Job Name Building Location System Contract Data File MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951 -667-4220 CYPRESS AT THE PRESERVE PLAN 1 CALC AREA 3 1 PLAN1CA316X16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical CYPRESS AT THE PRESERVE HYDRAULIC DESI GN INFORMATION SHEET Name -CYPRESS AT THE PRESERVE Location -CALC AREA 3 Building -PLAN 1 Date -5/25/17 System No . -1 Contract No. - Drawing No . -1 Contractor -NP MECHANICAL Cal culated By -MG Const ruction : (X) Combustible OCCUPANCY -LIGHT HAZARD ( ) Non-Combustible Cei l ing Height 9 '-0 " s y s T E M D E s I G N Type of Calculation: ( ) NFPA 13 Residential Number of Sprinklers Flowing: ( )1 (X)2 ( ) Other ( ) Specific Ruling Made by Listed Flow at Start Point -13 Listed Pres . at Start Point -7 MAXIMUM LISTED SPACING 1 6 x 16 -5 Gpm Psi )NFPA 13R (X)NFPA 130 ) 4 ( ) Date System Type (X) Wet ( ) Dry ( ) Deluge ( ) PreAction Sprinkler or Nozzle Domestic Flow Added Additional Flow Added Elevation at Highest Outlet - Gpm Gpm Feet Make RELIABLE Model RFC49 Size 7/16 K-Factor 4 .9 Note: Temperature Rating 165 Calculation Summary Gpm Required 26 .066 C-Factor Used : Psi Required 43.327 Overhead 150 At BR Underground 150 w A T E R s p p L y Water Flow Test : Date of Test Time of Test Static (Psi) - Residual (Psi) - Flow (Gpm) - Elevation - Location: Pump Rated @ Psi 94 Elev. 66 Other 3750 114 Data : Cap. Tank or Reservoir: Cap. Elev . Well Proof Flow Gpm Source of Information : Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page Date 1 5/25/17 Water Supply Curve C NP Mechanical CYPRESSATTHEPRESERVE City Water Supply: C1 -Static Pressure : 84.6 C2 -Residual Pressure: 59.4 C2 -Residual Flow 3750 150 140 130 p 120 R 110 E 100 S 90 rn;T S 80 l I D2 U 70 ( R 60 D3 E 50 40 30 20 l I D1 10 400 800 1200 1600 Page 2 Date 5/25/17 Demand: 2000 2400 2800 3200 FLOW ( N " 1 .85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 D1 -Elevation D2 -System Flow D2 -System Pressure Hose ( Demand ) D3 -System Demand Safety Margin 3600 : 16.458 : 26.066 : 72.170 :5 : 31.066 : 12.426 C2 Fittings Used Summary NP Mechanical CYPRESS AT THE PRESERVE Fitting Legend Abbrev. Name F NFPA 13 45' Elbow Fsp Flow Switch Potter VSR N * CPVC 90'EII Harvel-Spears O * CPVC Tee -Branch R* CPVC Coupling Tee -Run s NFPA 13 Swing Check T NFPA 13 90' Flowthru Tee Units Summary Diameter Units Length Units Flow Units Pressure Units ½ ¾ 1 1¼ 1½ 2 1 1 1 1 2 2 Fitting generates a Fixed Loss Based on Flow 3 1 0 3 Inches Feet 7 3 1 0 4 7 8 5 6 1 1 5 7 5 6 US Gallons per Minute Pounds per Square Inch 9 11 8 10 1 1 9 11 8 10 2½ 3 3 3 12 13 12 15 2 2 14 16 12 15 Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors 3½ 3 0 0 0 19 17 of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a* will be adjusted in the calculation for CF actors of other than 120 and diameters other than Sched 40 per NFPA. 4 5 6 8 4 5 7 9 0 0 0 0 0 0 0 0 0 0 0 0 22 27 32 45 20 25 30 35 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date 5/25/17 10 12 14 16 18 20 24 11 13 17 19 21 24 28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 55 65 50 60 71 81 91 101 121 ,, Pressure / Flow Summary -STANDARD NP Mechanical Page 4 CYPRESS AT THE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Re . H1 9.0 13.24 na H2 9.0 13.24 na H3 19.0 10.38 na H4 19.0 4.9 7.11 na 13.07 0.05 256 7.0 HS 19.0 4.9 7.04 na 13.0 0.05 256 7.039 1 10.0 12.81 na D1 10.0 12.81 na D2 10.0 12.81 na 2 10.0 12.81 na 3 10.0 12.81 na 4 20.0 8.48 na D5 20.0 7.36 na 5 20.0 7.69 na D4 20.0 7.06 na 6 20.0 7.69 na D3 20.0 9.95 na 7 20.0 9.95 na 8 20.0 11.24 na 10 20.0 12.82 na 11 20.0 8.92 na 12 10.0 23.23 na 13 10.0 29.04 na 14 10.0 31.03 na TR 10.0 33.91 na BR 2.0 43.33 na 5.0 X 2.0 44.4 na EL -3.0 46.99 na M1 -3.0 52.5 na M2 -3.0 56.72 na CM -3.0 65.24 na 100 -3.0 65.24 na 101 -3.0 65.24 na 102 -3.0 65.24 na 103 -3.0 65.24 na 104 -3.0 65.24 na FT -19.0 72.17 na The maximum velocity is 13.94 and it occurs in the pipe between nodes 10 and 12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Dia. ucu Fitting or Hyd. Ref. Point Qa Qt Pf/Ft Eqv. Ln. H1 0.0 0.874 0 3.0 to 150.0 0.0 D1 0.0 0.0 0.0 0.0 0.0 H2 0.0 0.874 0 3.0 to 150.0 0.0 D2 0.0 0.0 0.0 0.0 0.0 H3 0.0 0.874 N 7.0 to 150.0 0.0 D3 0.0 0.0 0.0 0.0 0.0 H4 13.07 0.874 0 3.0 to 150.0 0.0 D4 13.07 0.0952 0.0 0.0 13.07 H5 13.00 0.874 N 7.0 to 150.0 0.0 D5 13.0 0.0944 0.0 0.0 13.00 0.0 0.874 R 1.0 to 150.0 0.0 D1 0.0 0.0 0.0 D1 0.0 0.874 2N 14.0 to 150.0 R 1.0 D2 0.0 0.0 0.0 D2 0.0 0.874 0 3.0 to 150.0 0.0 2 0.0 0.0 0.0 2 0.0 0.874 0 3.0 to 150.0 0.0 3 0.0 0.0 0.0 3 0.0 0.874 0 3.0 to 150.0 0.0 1 0.0 0.0 0.0 0.0 0.0 3 0.0 0.874 0 3.0 to 150.0 0.0 4 0.0 0.0 0.0 4 -13.68 0.874 R 1.0 to 150.0 0.0 5 -13.68 -0.1037 0.0 Pipe Ftng's Total 1.000 3.000 4.000 1.000 3.000 4.000 1.000 7.000 8.000 1.000 3.000 4.000 1.000 7.000 8.000 13.750 1.000 14.750 12.333 15.000 27.333 13.917 3.000 16.917 5.917 3.000 8.917 5.667 3.000 8.667 10.000 3.000 13.000 6.583 1.000 7.583 Pt Pe Pf 13.242 -0.433 0.0 12.809 13.242 -0.433 0.0 12.809 10.379 -0.433 0.0 9.946 7.111 -0.433 0.381 7.059 7.039 -0.433 0.755 7.361 12.809 0.0 0.0 12.809 0.0 0.0 12.809 0.0 0.0 12.809 0.0 0.0 12.809 0.0 0.0 12.809 12.809 -4.331 0.0 8.478 0.0 -0.786 Pt Pv Pn Page 5 Date 5/25/17 ******* Notes ****** Vel = 0 K Factor = 0 Vel = 0 K Factor= 0 Vel = 0 K Factor= 0 K Factor = 4.90 Vel = 6.99 K Factor= 4.92 K Factor = 4.90 Vel = 6.95 K Factor = 4.79 Vel = 0 Vel = 0 Vel =0 Vel = 0 Vel = 0 K Factor = 0 Vel = 0 Vel= 7.32 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 F·inal Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point D5 to 5 5 to 6 D4 to 6 6 to 7 D3 to 7 7 to 8 8 to 10 10 to 11 11 to 4 10 to 12 12 to 13 13 to 14 14 to TR Qa Qt 0.0 -13.68 13.00 13.0 -13.68 -0.68 0.0 -0.68 13.07 13.07 -0.68 12.39 0.0 12.39 0.0 0.0 12.39 12.39 0.0 12.39 -26.07 -13.68 0.0 -13.68 0.0 -13.68 26.07 26.07 0.0 26.07 0.0 26.07 0.0 26.07 0.0 Dia. "C" Pf/Ft 0.874 150.0 0.0946 0.874 150.0 -0.0004 0.874 150.0 0.0952 0.874 150.0 0.0864 0.874 150.0 0.0 0.874 150.0 0.0864 0.874 150.0 0.0863 0.874 150.0 -0.1037 0.874 150.0 -0.1038 0.874 150.0 0.3420 0.874 150.0 0.3419 0.874 150.0 0.3418 0.874 150.0 0.3420 Fitting or Eqv. Ln. 0 3.0 0.0 0.0 N 7.0 R 1.0 0.0 0 3.0 0.0 0.0 3R 3.0 0.0 0.0 20 6.0 0.0 0.0 N 7.0 0.0 0.0 0 3.0 0.0 0.0 3R 3.0 0 3.0 0.0 R 1.0 0.0 0.0 2N 14.0 0.0 0.0 N 7.0 0.0 0.0 0 3.0 0.0 0.0 N 7.0 0.0 0.0 Pipe Ftng's Total 0.500 3.000 3.500 5.667 8.000 13.667 3.583 3.000 6.583 23.167 3.000 26.167 6.250 6.000 12.250 8.000 7.000 15.000 15.333 3.000 18.333 31.667 6.000 37.667 3.250 1.000 4.250 3.750 14.000 17.750 10.000 7.000 17.000 2.833 3.000 5.833 1.417 7.000 8.417 Pt Pe Pf 7.692 7.361 0.0 0.331 7.692 0.0 -0.006 7.686 7.059 0.0 0.627 7.686 0.0 2.260 9.946 9.946 0.0 0.0 9.946 0.0 1.296 11.242 0.0 1.583 12.825 0.0 -3.906 8.919 0.0 -0.441 8.478 12.825 4.331 6.070 23.226 0.0 5.813 29.039 0.0 1.994 31.033 0.0 2.879 Pt Pv Pn Page 6 Date 5/25/1 7 ******* Notes ****** K Factor = -4.93 Vel = 6.95 Vel = 0.36 K Factor= -0.25 Vel= 6.99 Vel = 6.63 K Factor = 3.93 Vel = 0 Vel = 6.63 Vel= 6.63 Vel = 7.32 Vel = 7.32 K Factor = -4.70 Vel = 13.94 Vel = 13.94 Vel = 13.94 Vel = 13.94 Computer Programs by Hydratec Inc. Route 11 1 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point TR to BR BR to X X to EL EL to M1 M1 to M2 M2 to CM CM to 100 100 to 101 100 to 105 101 to 102 102 to 103 103 to 104 104 to 105 104 to CM Qa Qt 26.07 26.07 26.07 5.00 31.07 0.0 31.07 0.0 31.07 0.0 31.07 0.0 31 .07 -14.03 17.04 0.87 17.91 0.0 17.91 -0.87 -0.87 0.0 -0.87 17.91 17.91 -31.07 -13.16 0.0 -13.16 14.03 0.87 0.0 0 .87 -14.03 -14.03 Dia. Helt Pf/Ft 1.101 150.0 0.1111 1.101 150.0 0.1537 1.244 150.0 0.0846 1.244 150.0 0.0848 1.025 150.0 0.2180 0.995 150.0 0.2516 7.98 150.0 0.0 7.98 150.0 0.0 7.98 150.0 0.0 11.65 150.0 0.0 11.65 150.0 0.0 7.98 150.0 0.0 11 .65 150.0 0.0 7.98 150.0 0.0 Fitting or Eqv. Ln. 2R 2.0 s 9.563 Fsp 0.0 N 7.0 0 5.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 T 5.841 0.0 0.0 3F 40.774 T 52.855 0.0 T 52.855 0.0 0.0 2T 105.71 0.0 0.0 F 17.441 T 80.498 0.0 F 17.441 T 80.498 0.0 T 52.855 0.0 0.0 T 80.498 0.0 0.0 T 52.855 0.0 0.0 Pipe Ftng's Total 8.000 18.562 26.562 2.000 5.000 7.000 5.000 0.0 5.000 65.000 0.0 65.000 1.000 0.0 1.000 28.000 5.841 33.841 324.000 93.629 417.629 295.000 52.855 347.855 381.000 105.710 486.710 175.000 97.939 272.939 532.000 97.939 629.939 542.000 52.855 594.855 207.000 80.498 287.498 542.000 52.855 594.855 Pt Pe Pf 33.912 33.912 6.465 2.950 43.327 0.0 1.076 44.403 2.166 0.423 46.992 0.0 5.51 1 52.503 4.000 0.218 56.721 0.0 8.514 65.235 0.0 0.002 65.237 0.0 0.001 65.238 65.237 -1.299 0.0 63.938 65.238 0.0 0.0 65.238 0.0 0.0 65.238 0.0 -0.001 65.237 -1.299 0.0 63.938 65.237 0.0 -0.002 Pt Pv Pn Page 7 Date 5/25/17 ******* Notes ****** K Factor= 4.48 * * Fixed Loss = 3 Vel = 8.79 Oa= 5 Vel = 10.47 Vel = 8.20 Vel = 8.20 * * Fixed Loss = 4 Vel = 12.08 Vel = 12.82 Vel = 0.11 Vel = 0.11 K Factor= 2.22 Vel = 0.01 K Factor= -0.1 1 Vel = 0.05 Vel = 0.04 Vel = 0.08 Vel = 0 K Factor= 0.11 Vel = 0.09 Computer Programs by Hydratec Inc. Route 11 1 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point 102 to FT Qa Qt 0.0 -14.03 31.07 31.07 0.0 31 .07 Dia. "C" Pf/Ft 11 .65 150.0 0.0 Fitting or Eqv. Ln. 3T 241 .494 0.0 0.0 Pipe Ftng's Total 1439.000 241.494 1680.494 Pt Pe Pf 65.235 65.238 6.930 0.002 72.170 Pt Pv Pn Page 8 Date 5/25/17 ******* Notes ****** K Factor= -1.74 Vel = 0.09 K Factor= 3.66 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Job Name Building Location System Contract Data File MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951 -667-4220 CYPRESS AT THE PRESERVE PLAN 1 ALT. CALC AREA 1 1 ALT. PLAN1 CA1 16X16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical CYPRESS AT THE PRESERVE HYDRAULIC DESIGN INFORMATION SHEET Name -CYPRESS AT THE PRESERVE Location -ALT . CALC AREA 1 Buil ding -PLAN 1 Date -5/25/17 System No . -1 Contract No . - Drawing No . -1 Contractor -NP MECHANICAL Calculated By -MG Construction: (X) Combustibl e OCCUPANCY -LIGHT HAZARD ( ) Non-Combu stible Ceiling Height 9 ' -0 " s y s T E M D E s I G N Type of Calculation : ( ) NFPA 13 Residential Number of Sprinklers Flowing: ( )1 (X)2 ( ) Other ( ) Specific Ru l ing Made by Listed Flow at Start Point -13 Listed Pres . at Start Point -7 MAXIMUM LISTED SPACING 16 x 16 Domestic Fl ow Added -5 Gpm Psi )NFPA 13R (X)NFPA 13D ) 4 ( ) Date System Type (X) Wet ( ) Dry ( ) Deluge ( ) PreAction Sprinkler or Nozzle Additional Flow Added Gpm Gpm Feet Make RELIABLE Model RFC49 Elevation at Hi ghest Outlet - Note : Size 7/16 K-Factor 4 .9 Temperature Rating 165 Calculation Summary Gpm Required 26 .003 C-Factor Used: Psi Requ i red 51 .530 Overhead 150 At BR Underground 150 w A T E R s p p L y Water Flow Test: Date of Test Time of Test Static (Psi) - Residual (Psi) - Flow (Gpm) - Elevation - Location : Pump Rated @ Psi 94 Elev . 66 Other 3750 114 Data: Cap. Tank or Reservoir: Cap . Elev . Well Proof Flow Gpm Source of Information: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page Date 1 5/25/17 Water Supply Curve C NP Mechanical CYPRESS AT THE PRESERVE City Water Supply: C1 -Static Pressure : 84.6 C2 -Residual Pressure: 59.4 C2 -Residual Flow 3750 150 140 130 P 120 R 110 E 100 S 90 S 80 U 70 D3 R 60 E 50 40 30 20 I 10 -.:;T _n., LTT 400 800 1200 1600 Page 2 Date 5/25/17 Demand: 2000 2400 2800 3200 FLOW ( N " 1 .85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 01 -Elevation 02 -System Flow 02 -System Pressure Hose ( Demand ) 03 -System Demand Safety Margin 3600 : 12.127 : 26.003 : 80.314 :5 : 31 .003 : 4.282 C2 .. Fittings Used Summary NP Mechanical CYPRESS AT THE PRESERVE Fitting Legend Abbrev. Name F NFPA 13 45' Elbow Fsp Flow Switch Potter VSR N * CPVC 90'EII Harvel-Spears O* CPVC Tee -Branch R* CPVC Coupling Tee -Run s NFPA 13 Swing Check T NFPA 13 90' Flow thru Tee Units Summary Diameter Units Length Units Flow Units Pressure Units ½ ¾ 1 1¼ 1½ 2 1 1 1 1 2 2 Fitting generates a Fixed Loss Based on Flow 7 3 3 1 1 0 0 3 4 Inches Feet 7 8 5 6 1 1 5 7 5 6 US Gallons per Minute Pounds per Square Inch 9 11 8 10 1 1 9 11 8 10 2½ 3 3½ 3 3 3 12 13 0 12 15 0 2 2 0 14 16 19 12 15 17 Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with*. The fittings marked with a* show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a* will be adjusted in the calculation for CF actors of other than 120 and diameters other than Sched 40 per NFPA. 4 5 6 8 4 5 7 9 0 0 0 0 0 0 0 0 0 0 0 0 22 27 32 45 20 25 30 35 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date 5/25/17 10 12 14 16 18 20 24 11 13 17 19 21 24 28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 55 65 50 60 71 81 91 101 121 ,., Pressure I Flow Summary -STANDARD NP Mechanical Page 4 CYPRESS AT THE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Re. H1 9.0 4.9 7.04 na 13.0 0.05 256 7.0 H2 9.0 4.9 7.04 na 13.0 0.05 256 7.039 H3 19.0 17.21 na H4 19.0 12.33 na HS 19.0 10.72 na 1 10.0 8.45 na D1 10.0 6.99 na D2 10.0 6.98 na 2 10.0 8.5 na 3 10.0 9.31 na 4 20.0 9.4 na D5 20.0 10.29 na 5 20.0 10.29 na D4 20.0 11 .89 na 6 20.0 11 .89 na 7 20.0 14.96 na 8 20.0 13.85 na 10 20.0 12.5 na 11 20.0 9.71 na D3 20.0 16.78 na A 20.0 16.78 na B 20.0 20.52 na C 10.0 30.64 na D 10.0 33.5 na E 10.0 36.11 na F 10.0 37.62 na TRA 10.0 42.13 na BR 2.0 51.53 na 5.0 X 2.0 52.6 na EL -3.0 55.19 na M1 -3.0 60.68 na M2 -3.0 64.9 na CM -3.0 73.38 na 100 -3.0 73.38 na 101 -3.0 73.38 na 102 -3.0 73.38 na 103 -3.0 73.38 na 104 -3.0 73.38 na FT -19.0 80.31 na The maximum velocity is 13.9 and it occurs in the pipe between nodes 3 and 4 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point H1 to D1 H2 to D2 H3 to D3 H4 to D4 H5 to D5 to D1 D1 to D2 D2 to 2 2 to 3 3 to 1 3 to 4 4 to 5 Qa Qt 13.00 13.0 0.0 13.00 13.00 13.0 0.0 13.00 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 -13.34 -13.34 13.00 -0.34 13.00 12.66 0.0 12.66 -26.00 -13.34 0.0 -13.34 26.00 26.0 -11 .38 14.62 Dia. "C" Pf/Ft 0.874 150.0 0.0945 0.874 150.0 0.0945 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 -0.0991 0.874 150.0 -0.0001 0.874 150.0 0.0899 0.874 150.0 0.0899 0.874 150.0 -0.0990 0.874 150.0 0.3405 0.874 150.0 0.11 72 Fitting or Eqv. Ln. 0 3.0 0.0 0.0 0 3.0 0.0 0.0 N 7.0 0.0 0.0 0 3.0 0.0 0.0 N 7.0 0.0 0.0 R 1.0 0.0 0.0 2N 14.0 R 1.0 0.0 0 3.0 0.0 0.0 0 3.0 0.0 0.0 0 3.0 0.0 0.0 0 3.0 0.0 0.0 R 1.0 0.0 0.0 Pipe Ftng's Total 1.000 3.000 4.000 1.000 3.000 4.000 1.000 7.000 8.000 1.000 3.000 4.000 1.000 7.000 8.000 13.750 1.000 14.750 12.333 15.000 27.333 13.917 3.000 16.917 5.91 7 3.000 8.91 7 5.667 3.000 8.667 10.000 3.000 13.000 6.583 1.000 7.583 Pt Pe Pf 7.042 -0.433 0.378 6.987 7.039 -0.433 0.378 6.984 17.209 -0.433 0.0 16.776 12.325 -0.433 0.0 11 .892 10.723 -0.433 0.0 10.290 8.448 0.0 -1.461 6.987 0.0 -0.003 6.984 0.0 1.520 8.504 0.0 0.802 9.306 0.0 -0.858 8.448 9.306 -4.331 4.426 9.401 0.0 0.889 Pt Pv Pn Page 5 Date 5/25/17 ******* Notes ****** K Factor= 4.90 Vel = 6.95 K Factor= 4.92 K Factor = 4.90 Vel = 6.95 K Factor = 4.92 Vel = 0 K Factor= 0 Vel =0 K Factor= 0 Vel = 0 K Factor = 0 Vel = 7.13 Vel = 0.18 Vel = 6.77 Vel = 6.77 Vel = 7.13 K Factor = -4.59 Vel = 13.90 Vel = 7.82 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 P'inal Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Dia. "C" Fitting or Hyd. Ref. Point Qa Qt Pf/Ft Eqv. Ln. 0.0 14.62 D5 0.0 0.874 0 3.0 to 150.0 0.0 5 0.0 0.0 0.0 5 14.62 0.874 N 7.0 to 150.0 R 1.0 6 14.62 0.11 72 0.0 0.0 14.62 D4 0.0 0.874 0 3.0 to 150.0 0.0 6 0.0 0.0 0.0 6 14.62 0.874 3R 3.0 to 150.0 0.0 7 14.62 0.1173 0.0 7 -26.01 0.874 N 7.0 to 150.0 0.0 8 -11.39 -0.0739 0.0 8 0.0 0.874 0 3.0 to 150.0 0.0 10 -11 .39 -0.0739 0.0 10 0.0 0.874 3R 3.0 to 150.0 0 3.0 11 -11 .39 -0.0739 0.0 11 0.0 0.874 R 1.0 to 150.0 0.0 4 -11 .39 -0.0739 0.0 0.0 -11 .39 7 26.00 0.874 R 1.0 to 150.0 0.0 A 26.0 0.3403 0.0 0.0 26.00 D3 0.0 0.874 0 3.0 to 150.0 0.0 A 0.0 0.0 0.0 A 26.00 0.874 N 7.0 to 150.0 0.0 B 26.0 0.3404 0.0 B 0.0 0.874 N 7.0 to 150.0 0.0 C 26.0 0.3405 0.0 C 0.0 0.874 0 3.0 to 150.0 0.0 D 26.0 0.3404 0.0 D 0.0 0.874 0 3.0 to 150.0 0.0 E 26.0 0.3404 0.0 Pipe Ftng's Total 0.500 3.000 3.500 5.667 8.000 13.667 3.583 3.000 6.583 23.167 3.000 26.167 8.000 7.000 15.000 15.333 3.000 18.333 31.667 6.000 37.667 3.250 1.000 4.250 4.333 1.000 5.333 2.000 3.000 5.000 4.000 7.000 11.000 10.000 7.000 17.000 5.417 3.000 8.417 4.667 3.000 7.667 Computer Programs by Hydratec Inc. Route 111 Pt Pe Pf 10.290 10.290 0.0 0.0 10.290 0.0 1.602 11.892 11.892 0.0 0.0 11 .892 0.0 3.069 14.961 0.0 -1.109 13.852 0.0 -1.354 12.498 0.0 -2.783 9.715 0.0 -0.314 9.401 14.961 0.0 1.815 16.776 16.776 0.0 0.0 16.776 0.0 3.744 20.520 4.331 5.788 30.639 0.0 2.865 33.504 0.0 2.610 Pt Pv Pn Page 6 Date 5/25/17 ******* Notes ****** K Factor= 4.56 Vel = 0 Vel = 7.82 K Factor = 4.24 Vel = 0 Vel = 7.82 Vel = 6.09 Vel = 6.09 Vel = 6.09 Vel = 6.09 K Factor = -3.71 Vel = 13.90 K Factor = 6.35 Vel = 0 Vel = 13.90 Vel = 13.90 Vel = 13.90 Vel = 13.90 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point E to F F to TRA TRA to BR BR to X X to EL EL to M1 M1 to M2 M2 to CM CM to 100 100 to 101 100 to 105 101 to 102 102 to 103 103 to 104 Qa Qt 0.0 26.0 0.0 26.0 0.0 26.00 26.00 26.0 5.00 31.0 0.0 31.0 0.0 31.0 0.0 31.0 0.0 31.0 -14.00 17.0 0.87 17.87 0.0 17.87 -0.87 -0.87 0.0 -0.87 17.87 17.87 -31 .00 -13.13 0.0 -13.13 Dia. "C" Pf/Ft 0.874 150.0 0.3403 0.874 150.0 0.3405 1.101 150.0 0.1106 1.101 150.0 0.1531 1.244 150.0 0.0842 1.244 150.0 0.0845 1.025 150.0 0.2170 0.995 150.0 0.2506 7.98 150.0 0.0 7.98 150.0 0.0 7.98 150.0 0.0 11 .65 150.0 0.0 11.65 150.0 0.0 7.98 150.0 0.0 Fitting or Eqv. Ln. 0 3.0 0.0 0.0 N 7.0 0 3.0 0.0 2R 2.0 s 9.563 Fsp 0.0 N 7.0 0 5.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 T 5.841 0.0 0.0 3F 40.774 T 52.855 0.0 T 52.855 0.0 0.0 2T 105.71 0.0 0.0 F 17.441 T 80.498 0.0 F 17.441 T 80.498 0.0 T 52.855 0 .0 0 .0 Pipe Ftng's Total 1.417 3.000 4.417 3.250 10.000 13.250 8.000 18.562 26.562 2.000 5.000 7.000 5.000 0.0 5.000 65.000 0.0 65.000 1.000 0.0 1.000 28.000 5.841 33.841 324.000 93.629 417.629 295.000 52.855 347.855 381.000 105.710 486.710 175.000 97.939 272.939 532.000 97.939 629.939 542.000 52.855 594.855 Pt Pe Pf 36.114 0.0 1.503 37.617 0.0 4.511 42.128 42.128 6.465 2.937 51 .530 0.0 1.072 52.602 2.166 0.421 55.189 0.0 5.491 60.680 4.000 0.217 64.897 0.0 8.482 73.379 0.0 0.001 73.380 0.0 0.002 73.382 73.380 -1.299 0.0 72.081 73.382 0.0 0.0 73.382 0.0 0.0 73.382 0.0 -0.002 Pt Pv Pn Page 7 Date 5/25/17 ******* Notes ****** Vel = 13.90 Vel = 13.90 K Factor= 4.01 * * Fixed Loss = 3 Vel = 8.76 Oa= 5 Vel = 10.45 Vel = 8.18 Vel = 8.18 * * Fixed Loss = 4 Vel = 12.05 Vel = 12.79 Vel = 0.11 Vel = 0.11 K Factor= 2.09 Vel = 0 .01 K Factor= -0.10 Vel = 0.05 Vel = 0.04 Vel = 0.08 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pinal Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point 104 to 105 104 to CM 102 to FT Qa Qt 14.00 0.87 0.0 0.87 -14.00 -14.0 0.0 -14.00 31.00 31.0 0.0 31 .00 Dia. "C" Pf/Ft 11 .65 150.0 0.0 7.98 150.0 0.0 11 .65 150.0 0.0 Fitting or Eqv. Ln. T 80.498 0.0 0.0 T 52.855 0.0 0.0 3T 241.494 0.0 0.0 Pipe Ftng's Total 207.000 80.498 287.498 542.000 52.855 594.855 1439.000 241.494 1680.494 Pt Pe Pf 73.380 -1.299 0.0 72.081 73.380 0.0 -0.001 73.379 73.382 6.930 0.002 80.314 Pt Pv Pn Page 8 Date 5/25/17 Notes ****** Vel = 0 K Factor = 0.10 Vel = 0.09 K Factor = -1.63 Vel = 0.09 K Factor= 3.46 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Job Name Building Location System Contract Data File MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951 -667-4220 CYPRESS AT THE PRESERVE PLAN 1 ALT. CALC AREA 2 1 ALT. PLAN1 CA2 20X20.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical CYPRESS AT THE PRESERVE HYDRAULIC DESIGN INFORMATION SHEET Name -CYPRESS AT THE PRESERVE Location -ALT. CALC AREA 2 Building -PLAN 1 Date -5/25/17 System No . -1 Contract No . - Drawing No. -1 Contractor -NP MECHANICAL Calculated By -MG Construction: (X) Combustible OCCUPANCY -LIGHT HAZARD ( ) Non-Combustible Ceiling Height 9 '-0 " s y s T E M D E s I G N Type of Calculation : ( )NFPA 1 3 Residential Number o f Sprinklers Flowing : (X)l ( )2 ( ) Other )NFPA 13R (X)NFPA 13D ) 4 ( ) ( )Speci fic Ruli ng Made by Date Listed Flow at Start Point -20 Gpm Listed Pres . a t Start Point -16 .7 Psi MAXIMUM LISTED SPACING 20 x 20 Domestic Flow Added -5 Additional Flow Added Elevation at Highest Outlet - Note: Gpm Gpm Feet (X ) Wet ( ) Deluge Sprinkler Make RELIABLE Size 7/16 Sys tem Type ( ) Dry ( ) PreAction or Nozzle Model RFC49 K-Factor 4.9 Temperature Rating 165 Calculation Summary Gpm Required 20 .024 C-Factor Used: Psi Required 44.567 Overhead 150 At BR Underground 150 w A T E R s p p L y Water Flow Test : Date of Test Time of Test Static (Psi) - Residual (Psi ) - Flow (Gpm) - Elevati on - Location : Pump Rated @ Psi 94 El ev. 66 Other 3750 114 Data: Cap . Tank or Reservoir : Cap. Elev. Well Proof Flow Gpm Source of I nformati on: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page Date 1 5/25/17 Water Supply Curve C NP Mechanical CYPRESS AT THE PRESERVE City Water Supply: C1 -Static Pressure : 84.6 C2 -Residual Pressure: 59.4 C2 -Residual Flow 3750 150 140 130 p 120 R 110 E 100 S 90 -.:-T s 80 U 70 ( D2 R 6003 E 50 40 30 20 ( D1 10 400 800 1200 1600 Page 2 Date 5/25/17 Demand: 2000 2400 2800 3200 FLOW ( N " 1 .85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 D1 -Elevation D2 -System Flow D2 -System Pressure Hose ( Demand ) D3 -System Demand Safety Margin 3600 : 16.458 : 20.024 : 68.21 7 :5 : 25.024 : 16.381 C2 -.. Fittings Used Summary NP Mechanical CYPRESS AT THE PRESERVE Fitting Legend Abbrev. Name F NFPA 13 45' Elbow Fsp Flow Switch Potter VSR N• CPVC 90'EII Harvel-Spears o· CPVC Tee -Branch R • CPVC Coupling Tee -Run s NFPA 13 Swing Check T NFPA 13 90' Flowthru Tee Units Summary Diameter Units Length Units Flow Units Pressure Units ½ ¾ 1 1¼ 1½ 2 1 1 1 1 2 2 Fitting generates a Fixed Loss Based on Flow 3 1 0 3 Inches Feet 7 3 1 0 4 7 8 5 6 1 1 5 7 5 6 US Gallons per Minute Pounds per Square Inch 9 11 8 10 1 1 9 11 8 10 2½ 3 3 3 12 13 12 15 2 2 14 16 12 15 Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors 3½ 3 0 0 0 19 17 of 120 except as noted with *. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. 4 5 6 8 4 5 7 9 0 0 0 0 0 0 0 0 0 0 0 0 22 27 32 45 20 25 30 35 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date 5/25/17 10 12 14 16 18 20 24 11 13 17 19 21 24 28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 55 65 50 60 71 81 91 101 121 .. Pressure I Flow Summary -STANDARD NP Mechanical Page 4 CYPRESS AT THE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. H1 9.0 23.76 na H2 9.0 23.76 na H3 19.0 4.9 16.7 na 20.02 0.05 400 16.7 H4 19.0 19.43 na HS 19.0 19.43 na 1 10.0 23.33 na 01 10.0 23.33 na 02 10.0 23.33 na 2 10.0 23.33 na 3 10.0 23.33 na 4 20.0 19.0 na 05 20.0 19.0 na 5 20.0 19.0 na 04 20.0 19.0 na 6 20.0 19.0 na 7 20.0 19.0 na 8 20.0 19.0 na 10 20.0 19.0 na 11 20.0 19.0 na 03 20.0 17.95 na A 20.0 19.0 na B 20.0 21.31 na C 10.0 29.21 na D 10.0 30.97 na E 10.0 32.58 na F 10.0 33.51 na TRA 10.0 36.29 na BR 2.0 44.57 na 5.0 X 2.0 45.29 na EL -3.0 47.74 na M1 -3.0 51.43 na M2 -3.0 55.58 na CM -3.0 61.28 na 100 -3.0 61 .28 na 101 -3.0 61.29 na 102 -3.0 61.29 na 103 -3.0 61 .29 na 104 -3.0 61.28 na FT -19.0 68.22 na The maximum velocity is 10.71 and it occurs in the pipe between nodes H3 and D3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point H1 to D1 H2 to D2 H3 to D3 H4 to D4 H5 to D5 to D1 D1 to D2 D2 to 2 2 to 3 3 to 1 3 to 4 4 to 5 Qa Qt 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 20.02 20.02 0.0 20.02 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Dia. "C" Pf/Ft 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.2099 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 Fitting or Eqv. Ln. 0 3.0 0.0 0.0 0 3.0 0.0 0.0 N 7.0 0.0 0.0 0 3.0 0.0 0.0 N 7.0 0.0 0.0 R 1.0 0.0 0.0 2N 14.0 R 1.0 0.0 0 3.0 0.0 0.0 0 3.0 0.0 0.0 0 3.0 0.0 0.0 0 3.0 0.0 0.0 R 1.0 0.0 0.0 Pipe Ftng's Total 1.000 3.000 4.000 1.000 3.000 4.000 1.000 7.000 8.000 1.000 3.000 4.000 1.000 7.000 8.000 13.750 1.000 14.750 12.333 15.000 27.333 13.917 3.000 16.917 5.917 3.000 8.917 5.667 3.000 8.667 10.000 3.000 13.000 6.583 1.000 7.583 Pt Pe Pf 23.760 -0.433 0.0 23.327 23.760 -0.433 0.0 23.327 16.700 -0.433 1.679 17.946 19.429 -0.433 0.0 18.996 19.429 -0.433 0.0 18.996 23.327 0.0 0.0 23.327 0.0 0.0 23.327 0.0 0.0 23.327 0.0 0.0 23.327 0.0 0.0 23.327 23.327 -4.331 0.0 18.996 0.0 0.0 Pt Pv Pn Page 5 Date 5/25/17 ******* Notes ****** Vel = 0 K Factor = 0 Vel = 0 K Factor = 0 K Factor= 4.90 Vel = 10.71 K Factor = 4.73 Vel = 0 K Factor = 0 Vel = 0 K Factor= 0 Vel = 0 Vel = 0 Vel = 0 Vel = 0 Vel = 0 K Factor= 0 Vel = 0 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Dia. "C" Fitting or Hyd. Ref. Point Qa Qt Pf/Ft Eqv. Ln. 0.0 0.0 05 0.0 0.874 0 3.0 to 150.0 0.0 5 0.0 0.0 0.0 5 0.0 0.874 N 7.0 to 150.0 R 1.0 6 0.0 0.0 0.0 0.0 0.0 04 0.0 0.874 0 3.0 to 150.0 0.0 6 0.0 0.0 0.0 6 0.0 0.874 3R 3.0 to 150.0 0.0 7 0.0 0.0 0.0 7 0.0 0.874 N 7.0 to 150.0 0.0 8 0.0 0.0 0.0 8 0.0 0.874 0 3.0 to 150.0 0.0 10 0.0 0.0 0.0 10 0.0 0.874 3R 3.0 to 150.0 0 3.0 11 0.0 0.0 0.0 11 0.0 0.874 R 1.0 to 150.0 0.0 4 0.0 0.0 0.0 0.0 0.0 7 0.0 0.874 R 1.0 to 150.0 0.0 A 0.0 0.0 0.0 0.0 0.0 03 20.02 0.874 0 3.0 to 150.0 0.0 A 20.02 0.2100 0.0 A 0.0 0.874 N 7.0 to 150.0 0.0 B 20.02 0.2099 0.0 B 0.0 0.874 N 7.0 to 150.0 0.0 C 20.02 0.2099 0.0 C 0.0 0.874 0 3.0 to 150.0 0.0 D 20.02 0.2099 0.0 D 0.0 0.874 0 3.0 to 150.0 0.0 E 20.02 0.2100 0.0 Pipe Ftng's Total 0.500 3.000 3.500 5.667 8.000 13.667 3.583 3.000 6.583 23.167 3.000 26.167 8.000 7.000 15.000 15.333 3.000 18.333 31 .667 6.000 37.667 3.250 1.000 4.250 4.333 1.000 5.333 2.000 3.000 5.000 4.000 7.000 11 .000 10.000 7.000 17.000 5.417 3.000 8.417 4.667 3.000 7.667 Computer Programs by Hydratec Inc. Route 111 Pt Pe Pf 18.996 18.996 0.0 0.0 18.996 0.0 0.0 18.996 18.996 0.0 0.0 18.996 0.0 0.0 18.996 0.0 0.0 18.996 0.0 0.0 18.996 0.0 0.0 18.996 0.0 0.0 18.996 18.996 0.0 0.0 18.996 17.946 0.0 1.050 18.996 0.0 2.309 21.305 4.331 3.569 29.205 0.0 1.767 30.972 0.0 1.610 Pt Pv Pn Page 6 Date 5/25/17 ******* Notes K Factor = 0 Vel = 0 Vel = 0 K Factor = 0 Vel = 0 Vel = 0 Vel = 0 Vel = 0 Vel = 0 Vel = 0 K Factor = 0 Vel =0 K Factor = 0 Vel = 10.71 Vel = 10.71 Vel = 10.71 Vel = 10.71 Vel = 10.71 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point E to F F to TRA TRA to BR BR to X X to EL EL to M1 M1 to M2 M2 to CM CM to 100 100 to 101 100 to 105 101 to 102 102 to 103 103 to 104 Qa Qt 0.0 20.02 0.0 20.02 0.0 20.02 20.02 20.02 5.00 25.02 0.0 25.02 0.0 25.02 0.0 25.02 0.0 25.02 -11.30 13.72 0.70 14.42 0.0 14.42 -0.70 -0.7 0.0 -0.70 14.42 14.42 -25.02 -10.6 0.0 -10.6 Dia. "C" Pf/Ft 0.874 150.0 0.2099 0.874 150.0 0.2100 1.101 150.0 0.0682 1.101 150.0 0.1030 1.244 150.0 0.0568 1.244 150.0 0.0568 1.025 150.0 0.1460 0.995 150.0 0.1686 7.98 150.0 0.0 7.98 150.0 0.0 7.98 150.0 0.0 11.65 150.0 0.0 11.65 150.0 0.0 7.98 150.0 0.0 Fitting or Eqv. Ln. 0 3.0 0.0 0.0 N 7.0 0 3.0 0.0 2R 2.0 s 9.563 Fsp 0.0 N 7.0 0 5.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 T 5.841 0.0 0.0 3F 40.774 T 52.855 0.0 T 52.855 0.0 0.0 2T 105.71 0.0 0.0 F 17.441 T 80.498 0.0 F 17.441 T 80.498 0.0 T 52.855 0.0 0.0 Pipe Ftng's Total 1.417 3.000 4.417 3.250 10.000 13.250 8.000 18.562 26.562 2.000 5.000 7.000 5.000 0.0 5.000 65.000 0.0 65.000 1.000 0.0 1.000 28.000 5.841 33.841 324.000 93.629 417.629 295.000 52.855 347.855 381.000 105.710 486.710 175.000 97.939 272.939 532.000 97.939 629.939 542.000 52.855 594.855 Pt Pe Pf 32.582 0.0 0.927 33.509 0.0 2.782 36.291 36.291 6.465 1.811 44.567 0.0 0.721 45.288 2.166 0.284 47.738 0.0 3.693 51.431 4.000 0.146 55.577 0.0 5.707 61 .284 0.0 0.001 61 .285 0.0 0.001 61.286 61.285 -1.299 0.0 59.986 61.286 0.0 0.0 61 .286 0.0 0.0 61 .286 0.0 -0.001 Pt Pv Pn Page 7 Date 5/25/17 Notes Vel = 10.71 Vel = 10.71 K Factor= 3.32 • • Fixed Loss = 3 Vel = 6.75 Oa= 5 Vel = 8.43 Vel = 6.60 Vel = 6.60 • • Fixed Loss = 4 Vel = 9.73 Vel = 10.32 Vel = 0.09 Vel = 0.09 K Factor= 1.84 Vel = 0 K Factor= -0.09 Vel = 0.04 Vel = 0.03 Vel = 0.07 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ... Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point 104 to 105 104 to CM 102 to FT Qa Qt 11 .30 0.7 0.0 0.70 -1 1.30 -11.3 0.0 -11.30 25.02 25.02 0.0 25.02 Dia. "C" Pf/Ft 11.65 150.0 0.0 7.98 150.0 0.0 11 .65 150.0 0.0 Fitting or Eqv. Ln. T 80.498 0.0 0.0 T 52.855 0.0 0.0 3T 241.494 0.0 0.0 Pipe Ftng's Total 207.000 80.498 287.498 542.000 52.855 594.855 1439.000 241.494 1680.494 Pt Pe Pf 61.285 -1.299 0.0 59.986 61.285 0.0 -0.001 61.284 61.286 6.930 0.001 68.217 Pt Pv Pn Page 8 Date 5/25/17 ******* Notes ****** Vel = 0 K Factor = 0.09 Vel = 0.07 K Factor = -1.44 Vel= 0.08 K Factor= 3.03 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Job Name Building Location System Contract Data File MECHANICAL NP Mechanical 9225 Stellar Court, Suite A Corona, CA 92883 951-667 -4220 CYPRESS AT THE PRESERVE PLAN 1 ALT. CALC AREA 3 1 ALT. PLAN1 CA3 16X16.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 NP Mechanical CYPRESS AT THE PRESERVE HYDRAULIC DESIGN INFORMATION SHEET Name -CYPRESS AT THE PRESERVE Location -ALT . CALC AREA 3 Building -PLAN 1 Contractor -NP MECHANICAL Calculated By -MG Construction: (X) Combustible OCCUPANCY -LIGHT HAZARD Date -5/25/17 System No . -1 Contract No . - Drawing No . -1 ( ) Non-Combustible Ceiling Height 9 '-0" s y s T E M Type of Calculation : ( )NFPA 13 Residential Number of Sprinklers Flowing : ( )1 (X)2 ( ) Other )NFPA 13R (X)NFPA 13D ) 4 ( ) ( ) Specific Ruling Made by Date D E s I G N Listed Flow at Start Point Listed Pres . at Start Point MAXIMUM LISTED SPACING 16 Domestic Flow Added Additional Flow Added Elevation at Highest Outlet Note : Calculation Summary Gpm Required 26 .176 C-Factor Used : w Water Flow Test: A Date of Test T Time of Test E Static (Psi) -94 R Residual (Psi) -66 Flow (Gpm) -3750 s Elevation -114 p Location: p L Source of Information: y -13 Gpm System Type -7 Psi (X) Wet ( ) Dry X 16 ( ) Deluge ( ) PreActi on -5 Gpm Sprinkler or Nozzle Gpm Make RELIABLE Model RFC49 -Feet Size 7/16 K-Factor 4.9 Temperature Rating 165 Psi Required 48 .738 Overhead 150 At BR Underground 150 Pump Rated @ Psi Elev . Other Data : Cap . Tank or Reservoir : Cap . Elev. Well Proof Flow Gpm Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page Date 1 5/25/17 Water Supply Curve C NP Mechanical CYPRESS AT THE PRESERVE City Water Supply: C1 -Static Pressure : 84.6 C2 -Residual Pressure: 59.4 C2 -Residual Flow 3750 150 140 130 p 120 R 110 E 100 S 90 7:,T s 80 oz U 7o D31 i R 60 E 50 40 30 20 ( 01 10 400 800 1200 1600 Page 2 Date 5/25/17 Demand: 2000 2400 2800 3200 FLOW ( N " 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 D1 -Elevation 02 -System Flow 02 -System Pressure Hose ( Demand ) 03 -System Demand Safety Margin 3600 : 16.458 : 26.176 : 77.684 :5 :31.176 : 6.912 C2 Fittings Used Summary NP Mechanical CYPRESSATTHE PRESERVE Fitting Legend Abbrev. Name F NFPA 13 45' Elbow Fsp Flow Switch Potter VSR N* CPVC 90'EII Harvel-Spears o· CPVC Tee -Branch R* CPVC Coupling Tee -Run s NFPA 13 Swing Check T NFPA 13 90' Flow thru Tee Units Summary Diameter Units Length Units Flow Units Pressure Units ½ ¾ 1 1¼ 1½ 2 1 1 1 1 2 2 Fitting generates a Fixed Loss Based on Flow 3 1 0 3 Inches Feet 7 3 1 0 4 7 8 5 6 1 1 5 7 5 6 US Gallons per Minute Pounds per Square Inch 9 11 8 10 1 1 9 11 8 10 2½ 3 3 3 12 13 12 15 2 2 14 16 12 15 Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors 3½ 3 0 0 0 19 17 of 120 except as noted with •. The fittings marked with a • show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a• will be adjusted in the calculation for CF actors of other than 120 and diameters other than Sched 40 per NFPA. 4 5 6 8 4 5 7 9 0 0 0 0 0 0 0 0 0 0 0 0 22 27 32 45 20 25 30 35 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 3 Date 5/25/17 10 12 14 16 18 20 24 11 13 17 19 21 24 28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 55 65 50 60 71 81 91 101 121 , Pressure / Flow Summary -STANDARD NP Mechanical Page 4 CYPRESS AT THE PRESERVE Date 5/25/17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. H1 9.0 12.84 na H2 9.0 12.84 na H3 19.0 14.12 na H4 19.0 4.9 7.23 na 13.18 0.05 256 7.0 HS 19.0 4.9 7.04 na 13.0 0.05 256 7.039 1 10.0 12.4 na 01 10.0 12.4 na 02 10.0 12.4 na 2 10.0 12.4 na 3 10.0 12.4 na 4 20.0 8.07 na D5 20.0 7.36 na 5 20.0 7.69 na 04 20.0 7.18 na 6 20.0 7.82 na 7 20.0 11 .85 na 8 20.0 11.1 na 10 20.0 10.18 na 11 20.0 8.29 na 03 20.0 13.69 na A 20.0 13.69 na B 20.0 17.48 na C 10.0 27.67 na 0 10.0 30.57 na E 10.0 33.21 na F 10.0 34.73 na TRA 10.0 39.3 na BR 2.0 48.74 na 5.0 X 2.0 49.82 na EL -3.0 52.41 na M1 -3.0 57.96 na M2 -3.0 62.18 na CM -3.0 70.75 na 100 -3.0 70.75 na 101 -3.0 70.75 na 102 ·3.0 70.75 na 103 -3.0 70.75 na 104 -3.0 70.75 na FT -19.0 77.68 na The maximum velocity is 14 and it occurs in the pipe between nodes 7 and A Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point H1 to D1 H2 to D2 H3 to D3 H4 to D4 H5 to D5 to D1 D1 to D2 D2 to 2 2 to 3 3 to 1 3 to 4 4 to 5 Oa Ot 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 13.18 13.18 0.0 13.18 13.00 13.0 0.0 13.00 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 -9.24 -9.24 Dia. "C" Pf/Ft 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0968 0.874 150.0 0.0944 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 0.0 0.874 150.0 -0.0501 Fitting or Eqv. Ln. 0 3.0 0.0 0.0 0 3.0 0.0 0.0 N 7.0 0.0 0.0 0 3.0 0.0 0.0 N 7.0 0.0 0.0 R 1.0 0.0 0.0 2N 14.0 R 1.0 0.0 0 3.0 0.0 0.0 0 3.0 0.0 0.0 0 3.0 0.0 0.0 0 3.0 0.0 0.0 R 1.0 0.0 0.0 Pipe Ftng's Total 1.000 3.000 4.000 1.000 3.000 4.000 1.000 7.000 8.000 1.000 3.000 4.000 1.000 7.000 8.000 13.750 1.000 14.750 12.333 15.000 27.333 13.917 3.000 16.917 5.917 3.000 8.917 5.667 3.000 8.667 10.000 3.000 13.000 6.583 1.000 7.583 Pt Pe Pf 12.836 -0.433 0.0 12.403 12.836 -0.433 0.0 12.403 14.122 -0.433 0.0 13.689 7.230 -0.433 0.387 7.184 7.039 -0.433 0.755 7.361 12.403 0.0 0.0 12.403 0.0 0.0 12.403 0.0 0.0 12.403 0.0 0.0 12.403 0.0 0.0 12.403 12.403 -4.331 0.0 8.072 0.0 -0.380 Pt Pv Pn Page 5 Date 5/25/17 ******* Notes ****** Vel = 0 K Factor = 0 Vel = 0 K Factor = 0 Vel = 0 K Factor= 0 K Factor = 4.90 Vel = 7.05 K Factor= 4.92 K Factor= 4.90 Vel = 6.95 K Factor = 4.79 Vel = 0 Vel = 0 Vel = 0 Vel = 0 Vel = 0 K Factor= 0 Vel = 0 Vel = 4.94 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Dia. "C" Fitting or Hyd. Ref. Point Qa Qt Pf/Ft Eqv. Ln. 0.0 -9.24 D5 13.00 0.874 0 3.0 to 150.0 0.0 5 13.0 0.0946 0.0 5 -9.24 0.874 N 7.0 to 150.0 R 1.0 6 3.76 0.0095 0.0 0.0 3.76 D4 13.18 0.874 0 3.0 to 150.0 0.0 6 13.18 0.0969 0.0 6 3.75 0.874 3R 3.0 to 150.0 0.0 7 16.93 0.1540 0.0 7 -26.17 0.874 N 7.0 to 150.0 0.0 8 -9.24 -0.0502 0.0 8 0.0 0.874 0 3.0 to 150.0 0.0 10 -9.24 -0.0502 0.0 10 0.0 0.874 3R 3.0 to 150.0 0 3.0 11 -9.24 -0.0502 0.0 11 0.0 0.874 R 1.0 to 150.0 0.0 4 -9.24 -0.0504 0.0 0.0 -9.24 7 26.18 0.874 R 1.0 to 150.0 0.0 A 26.18 0.3446 0.0 0.0 26.18 D3 0.0 0.874 0 3.0 to 150.0 0.0 A 0.0 0.0 0.0 A 26.18 0.874 N 7.0 to 150.0 0.0 B 26.18 0.3445 0.0 B 0.0 0.874 N 7.0 to 150.0 0.0 C 26.18 0.3446 0.0 C 0.0 0.874 0 3.0 to 150.0 0.0 D 26.18 0.3445 0.0 D 0.0 0.874 0 3.0 to 150.0 0.0 E 26.18 0.3447 0.0 Pipe Ftng's Total 0.500 3.000 3.500 5.667 8.000 13.667 3.583 3.000 6.583 23.167 3.000 26.167 8.000 7.000 15.000 15.333 3.000 18.333 31.667 6.000 37.667 3.250 1.000 4.250 4.333 1.000 5.333 2.000 3.000 5.000 4.000 7.000 11 .000 10.000 7.000 17.000 5.417 3.000 8.417 4.667 3.000 7.667 Computer Programs by Hydratec Inc. Route 111 Pt Pe Pf 7.692 7.361 0.0 0.331 7.692 0.0 0.130 7.822 7.184 0.0 0.638 7.822 0.0 4.029 11 .851 0.0 -0.753 11 .098 0.0 -0.921 10.177 0.0 -1.891 8.286 0.0 -0.214 8.072 11.851 0.0 1.838 13.689 13.689 0.0 0.0 13.689 0.0 3.790 17.479 4.331 5.859 27.669 0.0 2.900 30.569 0.0 2.643 Pt Pv Pn Page 6 Date 5/25/17 ******* Notes ****** K Factor = -3.33 Vel = 6.95 Vel = 2.01 K Factor = 1.34 Vel = 7.05 Vel = 9.05 Vel= 4.94 Vel = 4.94 Vel = 4.94 Vel = 4.94 K Factor = -3.25 Vel = 14.00 K Factor = 7.08 Vel = 0 Vel = 14.00 Vel = 14.00 Vel = 14.00 Vel = 14.00 Windham N.H. USA 03087 Final Calculations -Hazen-Will iams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point E to F F to TRA TRA to BR BR to X X to EL EL to M1 M1 to M2 M2 to CM CM to 100 100 to 101 100 to 105 101 to 102 102 to 103 103 to 104 Qa Qt 0.0 26.18 0.0 26.18 0.0 26.18 26.18 26.18 5.00 31 .18 0.0 31.18 0.0 31.18 0.0 31.18 0.0 31.18 -14.08 17.1 0.87 17.97 0.0 17.97 -0.87 -0.87 0.0 -0.87 17.97 17.97 -31.18 -13.21 0.0 -13.21 Dia. "C" Pf/Ft 0.874 150.0 0.3446 0.874 150.0 0.3446 1.101 150.0 0.1119 1.101 150.0 0.1547 1.244 150.0 0.0852 1.244 150.0 0.0853 1.025 150.0 0.2190 0.995 150.0 0.2532 7.98 150.0 0.0 7.98 150.0 0.0 7.98 150.0 0.0 11.65 150.0 0.0 11.65 150.0 0.0 7.98 150.0 0.0 Fitting or Eqv. Ln. 0 3.0 0.0 0.0 N 7.0 0 3.0 0.0 2R 2.0 s 9.563 Fsp 0.0 N 7.0 0 5.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 T 5.841 0.0 0.0 3F 40.774 T 52.855 0.0 T 52.855 0.0 0.0 2T 105.71 0.0 0.0 F 17.441 T 80.498 0.0 F 17.441 T 80.498 0.0 T 52.855 0.0 0.0 Pipe Ftng's Total 1.417 3.000 4.417 3.250 10.000 13.250 8.000 18.562 26.562 2.000 5.000 7.000 5.000 0.0 5.000 65.000 0.0 65.000 1.000 0.0 1.000 28.000 5.841 33.841 324.000 93.629 417.629 295.000 52.855 347.855 381.000 105.710 486.710 175.000 97.939 272.939 532.000 97.939 629.939 542.000 52.855 594.855 Pt Pe Pf 33.212 0.0 1.522 34.734 0.0 4.566 39.300 39.300 6.465 2.973 48.738 0.0 1.083 49.821 2.166 0.426 52.413 0.0 5.547 57.960 4.000 0.219 62.179 0.0 8.570 70.749 0.0 0.002 70.751 0.0 0.001 70.752 70.751 -1.299 -0.001 69.451 70.752 0.0 0.0 70.752 0.0 0.0 70.752 0.0 -0.001 Pt Pv Pn Page 7 Date 5/25/17 ******* Notes ****** Vel = 14.00 Vel = 14.00 K Factor = 4.18 * * Fixed Loss = 3 Vel = 8.82 Oa= 5 Vel = 10.51 Vel = 8.23 Vel = 8.23 * * Fixed Loss = 4 Vel = 12.12 Vel = 12.87 Vel = 0.11 Vel = 0.12 K Factor = 2.14 Vel = 0.01 K Factor= -0.10 Vel = 0.05 Vel = 0.04 Vel = 0.08 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 i=inal Calculations -Hazen-Williams NP Mechanical CYPRESS AT THE PRESERVE Hyd. Ref. Point 104 to 105 104 to CM 102 to FT Qa Qt 14.08 0.87 0.0 0.87 -14.08 -14.08 0.0 -14.08 31.18 31.18 0.0 31.18 Dia. "Cit Pf/Ft 11.65 150.0 0.0 7.98 150.0 0.0 11.65 150.0 0.0 Fitting or Eqv. Ln. T 80.498 0.0 0.0 T 52.855 0.0 0.0 3T 241.494 0.0 0.0 Pipe Ftng's Total 207.000 80.498 287.498 542.000 52.855 594.855 1439.000 241.494 1680.494 Pt Pe Pf 70.751 -1.299 -0.001 69.451 70.751 0.0 -0.002 70.749 70.752 6.930 0.002 77.684 Pt Pv Pn Page 8 Date 5/25/17 ******* Notes ****** Vel = 0 K Factor= 0.10 Vel = 0.09 K Factor = -1.67 Vel = 0.09 K Factor= 3.54 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Bulletin 006 Rev. I Model RFC30 (SIN RA0611) gi Reliabl~ Model RFC43 (SIN RA0612) ~ Model RFC49 (SIN RA0616) 8 0) Residential Flat Concealed :o Cl) Sprinklers ~ A Residential Flat Concealed Sprinkler engineered for a minimum design density of 0.05 gpm/ft2 with low GPM requirements. Features 1. Very low water flow requirements. 2. Cover plate attachment (Plain or Perforated) with½" (13mm) Total adjustment. 3. Thread-On/Thread-Off or Push-On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. 5. Available in brass, chrome and black plated or painted finishes. Listings & Approval 1. Listed by Underwriters Laboratories, certified by UL for Canada (cULus) UL Listing Categories Residential Automatic Sp rinklers UL Guide Number VKKW Product Description and Model RFC30, RFC43 and RFC49 Concealed Residen- tial Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC30, RFC43 and RFC49 sprinklers discharge water in a hemispherical pattern below the sprinkler de- flector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprin- kler patterns. The combination of speed of operation and high dis- charge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacu- ation time for occupants. The RFC30, RFC43 and RFC49 Sprinklers provide the best form of fire protection by combining an attractive ap- pearance and ½" (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily Plain Cover Plate --------· --·--------------------------·-----·---------------------------------------------·-·----------------------------------------------------------------------------------------------------------------------------------------------------------►--------------­_____________ ...,_ ------------------------------------·---------- Perforated Cover Plate and positively attached and b lends into the ceiling, con- cealing the most dependable fire protection available, an automatic sprinkler system. The RFC30, RFC43 and RFC49 are UL Li sted Residen- tial Sprinklers to be installed in the residential portions of any occupancy in accordance with NFPA 13, 13R. & 13D. The RFC30, RFC43 and RFC49 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit ac- curately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application and Installation The RFC30, RFC43 and RFC49, for residential instal- lations, use a 165°F (74°C) fusible solder link in a tun- ing fork style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature classifica- tion solder. When the ceiling temperature rises, the solder holding the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the de- flector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler de- flector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The resi- dential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces sig- nificantly higher wall wetting. After a 25/a inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexago- nal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe instal- lation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprin- kler/cup assembly, care should be taken to prevent dam- age to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F RATED COV- ERS. Note: A leak tight ½" NPT (R1/2) sprinkler joint can be ob- tained with a torque of 8-18 ft-lbs (10,8 -24.4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Cover assemblies provide up to ½" (13mm) of adjust- ment. Turn the cover clockwise until the flange is in con- tact with the ceil ing. For the push-on/thread-off option, the cover assembly is pushed onto the cup and final ad- justment is made by turning the cover clockwise unti l the skirt flange makes full contact with the ceiling. Cover re- moval requires turning in the counter-clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or neg- ative pressurization but must not be positively pres- surized. Inspect all sprinklers after installation to en- sure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment. Sprinkler CCP Assembly Max. Max. Thread Nominal Ambient K Model Size Orifice Temp Rating Temp. Rating Temp. Pressure Factor (SIN) Inch (mm) Inch (mm) psi (bar) •F ·c •F ·c •F ·c RFC30 ½" (1 5) (RA0611) 21/64 (8,2) 165 74 135 57 100 38 3.0 (43.2) 175 (12) RFC43 ½" (1 5) 3/4 (10) 165 74 (RA0612) 135 57 100 38 4.3 (62) 175 (12) RFC49 (RA0616) ½" (1 5) 7/,6 (11) 165 74 135 57 100 38 4.9 (70.6) 175 (12) Note: 1 bar= 100 Kpa RFC30 Ordinary Temp. Rating Top of Deflector Minimum Max. Coverage Max. Spacing (1 G5°Fn 4 °c) Installation area to Ceiling Type Spacing Ft X Ft (m X m) Ft (m) Flow Pressure Inch (mm) Ft (m) GPM (L/min) PSI (bar) 12 X 12 (3,6 X 3,6) 12 (3,6) 9 (34, 1) 9.0 (0,62) Smooth Ceilings½ to 1 (13 to 25.4) Beamed Ceilings per NFPA 13D, 13R or Concealed 8 (2,4) 14 X 14 (4,3 X 4,3) 14 (4,3) 10 (37,8) 11.0 (0,76) 13 installed in beams½ to 1 (13 to 25.4) For Ceiling types refer to NFPA 13, 13R or 13D 2. RFC43 Max. Coverage Ordinary Temp. Rating Max. Spacing (165°Fn4°C) area Ft (m) Ft X Ft (m X m) Flow Pressure GPM (L/min) PSI (bar) 12 X 12 (3,6 X 3,6) 12 (3,6) 12(4,5) 7.8 (0,54) 14 X 14 (4,3 X 4,3) 14 (4,3) 13 (49) 9.1 (0,63) 16 X 16 (4,9 X 4,9) 16 (4,9) 13 (49) 9.1 (0,63) 18 X 18 (5,5 X 5,5) 18 (5,5) 18 (68) 17.5 (1,21) 20 X 20 (6, 1 X 6, 1) 20 (6, 1) 21 (79) 23.8 (1 ,64) For Ceiling types refer to NFPA 13, 13R or 130 RFC49 Max. Coverage Ordinary Temp. Rating Max. Spacing (165°Fn4°C) area Ft (m) Flow Pressure Ft X Ft (m X m) GPM (L/minl PSI (bar) 12 X 12 (3,6 X 3,6) 12 (3,6) 13 (49) 7.0 (0,48) 14 X 14 (4,3 X 4,3) 14 (4,3) 13 (49) 7.0 (0,48) 16 X 16 (4,9 X 4,9) 16(4,9) 13 (49) 7.0 (0,48) 18 X 18 (5,5 X 5,5) 18 (5,5) 17 (64,3) 12.0 (0,83) 20 X 20 (6, 1 X 6, 1) 20 (6,1) 20 (75,73) 167(1 ,14) For Ceiling types refer to NFPA 13, 13R or 130 Maintenance Model RFC30, RFC43 and RFC49 Concealed Sprin- klers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate as- sembly which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprin- klers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non-operation. Model RFC30, RFC43 and RFC49 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential con- cealed sprinklers with drop-down deflector and adjust- able flat cover plate engineered for a minimum design density of 0.05 gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with Top of Deflector Minimum Installation to Ceiling Type Spacing Inch (mm) Ft (m) Smooth Ceilings½ to 1 (13 to 25.4) Beamed Ceilings per NFPA 130, 13R or Concealed 8 (2,4) 13 installed in beams ½ to 1 (13 to 25.4) Top of Deflector Minimum Installation to Ceiling Type Spacing Inch (mm) Ft (m) Smooth Ceilings ½ to 1 (13 to 25.4) Beamed Ceilings per NFPA 130, 13R or Concealed 8 (2,4) 13 installed in beams ½ to 1 (13 to 25.4) 3. symmetric lever mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K- factor shall be nominal 3.0 (43.2), 4.3 (62), and 4.9 (70.6) having a 5/16", %" and 7 /16" orifice. Temperature rating shall be Ordinary 165°F (74°C); cover plate temperature rating to be 135°F (57°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allowing a ½" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop-down sprinkler deflector from dam- age, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty -specify]. Residential concealed sprinklers shall be Reliable Model RFC30, SIN RA0611 (Bulletin 006), Model RFC43, SIN RA0612 (Bulletin 006) or Model RFC49, SIN RA0616 (Bulleti n 006). Ordering Information Cover Plate Finishes<1> Specify: 1. Sprinkler Model 2. Cover Plate Finish 3. Thread-On or Push-On Feature ./,• {12.70mm} UU'. ~ ADJUSTMENT 1/2" {12.70mm} ltl/N. TO 1 • [25.4mm] UU'. Standard Finishes Chrome White Paint Special Application Finishes(2> Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome 11> Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. 121 For the perforated style cover- plate, consult factory for avail- ability on these and other cus- tom finishes. CE/UNG /////// /////// ,; ,; /.,;,;,;,; 2" {50.8mm} UU'. FACE OF mnNG TO FACE OF C£JUNG Olltl£NSION l OROPP£0 DEFI..ECTOR TO CEIUNG CE/UNG FUT C0\,£1\' Pl.ATE ASSEltlBLY ~• {4.96mm} COVER PLATE: 1 /2" {12.7mm 7 ADJUSTMENT OO#fJOtC The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliabld Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ,;;,.. Recycled \V Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/14 P/N 9999970261 Bulletin 135 Rev.G OJ C Model F1 ~ s· Residential Sprinklers for w Design Density of .05 gpm/ft2 ~ < Reliabld ,;,;;__:_.;;,,_;_::==================-----,_-_-_-_::-_-_-_-_-_-_-_-_-_-_-_,--;...-:....-:....-_-_-_-_-_-_-_-_-_-_,-G) Model F1 Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpmlft' Types: 1. F1 Res 30 Pendent 2. F1 Res 30 Recessed Pendent/F2 3. F1 Res 30 Recessed Pendent/FP 4. F1 Res 49 Pendent 5. F1 Res 49 Recessed Pendent/F 1 6. F1 Res 49 Recessed Pendent/FP 7. F1 Res 58 Pendent 8. F1 Res 58 Recessed Pendent/F1 9. F1 Res 58 Recessed Pendent/FP 10. F1 Res 76 Pendent 11 . F1 Res 76 Recessed Pendent/F1 12. F1 Res 76 Recessed Pendent/FP 13. F1 Res 30 CCP Pendent 14. F1 Res 49 CCP Pendent 15. F1 Res 58 CCP Pendent 16. F1 Res 76 CCP Pendent 17. F1 Res 44 HSW 18. F1 Res 44 Recessed HSW/F2 19. F1 Res 58 HSW 20. F1 Res 58 HSW Recessed HSW/F2 21. F1 Res 44 SWC 22. F1 Res 40 HSW 23. F1 Res 40 Recessed HSW/F2 Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E Slope Ceiling Approvals: Refer to Bulletin 035 Sprinklers for .1 O Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers Product Description Model F1 Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitivity glass-bulb and low profile decorative design. The F1 Res Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attractive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. F1 Res 30, 49, 58 & 76 Recessed Pendent / F1 F1 Res 30, 49, 58 & 76 CCP Pendent F1 Res44SWC F1 Res 30, 49, 58 & 76 Recessed Pendent/ FP F1 Res 44&58 Recessed HSW/F2 F1 Res 40 Recessed HSW/F2 The low flow F1 Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass-bulb • Sprinkler Frame : Brass Casting • Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: ½" NPT (R½) • K-Factor: 3.0 (Actual) -F1 Res 30 Pendent Sprinkler 4.9 (Actual) -F1 Res 49 Pendent Sprinkler 5.8 (Actual) -F1 Res 58 Pendent & HSW Sprinkler 7.6 (Actual) -F1 Res 76 Pendent Sprinkler 4.4 (Actual)-F1 Res 44 HSW Sprinkler 4.0 (Actual) -F1 Res 40 HSW Sprinkler • Density: Minimum 0.05 gpm/ft2 Application Model F1 Res Sprinklers are used for Residential Fire Protection according to UL 1626 Standard*. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Installation Models F1 Res sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model F1 Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res Pendent sprinklers use only the Model D sprinkler Wrench; for in stalling Models F1 Res Recessed Pendent, CCP & • Model F1 Res 30, 49, 58 & 76 Pendent (--+--~ r-r-1 I I TURN COl.lNI UNll nt:Hr N::AJNSr SPRIHKL£R -,oss. SWC sprinklers use only the Model GFR2 sprinkler wrench; for installing Model F1 Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install F1 Res 44 and 40 HSW with a ceiling to deflector distance of 4" -12". Flow arrow on deflector must point away from near wall and "Top" marking must face ceiling. • Model F1 Res 30 Recessed Pendent/F2 • Model F1 Res 49, 58 & 76 Recessed Pendent I F1 F1 escutcheon,¾" (19mm) adjustment 2 1/4 • HOI.£ DM. t,u ..... J NWSIIIQ<r IJ5FCOJ Fig. 1 t IJ5FC02 Fig. 2 Escutcheon*, F1 or F2, Data: Adjustment "A" Face of fitting to Type ceiling lnch(mm) lnch(mm) lnch(mm) F1 ¾ (19.0) Min.=¾" (19.1) Max.=1½" /38.1) %-1% (4.7 -24.0) F2 ½ (12.7) Min.= 13/i's" (23.8) Max.=1½" /38.1) % -1.Ks (4.7 -17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49, 58 & 76 Recessed Pendent 2. ,. Technical Data: F1 Res 30 Pendent and Recessed Pendent Nominal Sprinkler Max. Max. Actual Thread Orifice Temp. Pressure Ambient Size Inch Ratina psi Temp. K (mm) OF °C (bar) OF °C Factor ½"NPT 2y64· (8.2) 155 68 175 (12) 100 38 3.0 -(RV.:\ 175 79 Deflector -to -ceiling Maximum 1" (25mm) to 4" (100mm) Max. Sp~inkler Flow Pressure S~ac~ng gpm (Lpm) psi (bar) 11 0.76 Sprinkler Identification Number SIN R351 1 Sprinkler Length Inch (mm) 2.25 (57) Technical Data: F1 Res 49 Pendent and Recessed Pendent Nominal Sprinkler Max. Max. Actual Sprinkler Thread Orifice Temp. Pressure Ambient Length Size Inch Ratina psi Temp. K Inch (mm) OF °C (bar) °F °C Factor (mm) ½"NPT Y,/(11) 155 68 175 (12) 100 38 4.9 2.25 (57) -(RV.:\ 175 79 150 66 Deflector -to -ceiling *Deflector -to -ceiling Maximum 1" (25mm) to 4" (100mm) Maximum 4" (100mm) to 8" (203mm) Max. Sp~inkler Flow Pressure S~ac~ng gpm (Lpm) psi (bar) 12 X 12 3.6X3.6 13 49 7.0 0.48 14 X 14 4.3X4.3 13 49 7.0 0.48 16 X 16 4.9X4.9 13 49 7.0 0.48 18 X 18 5.5X5.5 12.0 0.83 16.7 1.14 Sprinkler Identification Number SIN R3516 Max. Sprinkler Spacing ft m 12 X 12 3.6x3.6 14 X 14 4.3X4.3 16 X 16 4.9X4.9 Flow Pressure gpm (Lpm) psi (bar) 18 X 18 5.5x5.5 15.0 1.0 20 X 20 6.1 X6.1 Sprinkler Identification Number SIN R3516 *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth= 7" (178mm) 2. Beam spacing at or greater than 7.5 ft. (2.3m) on center. Technical Data: F1 Res 58 Pendent and Recessed Pendent Nominal Sprinkler Max. Max. Sprinkler Thread Orifice Temp. Pressure Ambient K Length Size Inch Ratina psi Temp. Factor Inch (mm) OF oc (bar) OF oc (mm) ½"NPT ½' (13) 155 68 175 (1 2) 100 38 5.8 2.25 (57) (R½) 175 79 150 66 Max. Sprinkler Flow Pressure Ceiling-to-Sprinkler Spacing gpm(Lpm) psi(bar) Deflector Identification ft m Inch mm Number SIN 12x12 3.6x3.6 16 61 14 X 14 4.3X4.3 16 61 16 61 1-4 R3513 (25-100) 19 72 20 X 20 6.1 X6.1 22 83.3 3. Technical Data: F1 Res 76 Pendent and Recessed Pendent Nominal Spn<ler l\fex. l\fex. Spn<ler Thread Orifioe TE!l11). Antin Lenglh Plessue K Size Inch ~ psi Tenn Pca:ll' heh (mm) OF oc (bar) OF oc (mm) ¾"NPT '½/ 155 68 175(12} 100 38 7.6 2.25 (57) (R3/.) (13.5) 175 79 150 66 Max. Sprinkler Sprinkler Flow Pressure Spacing gpm(Lpm) psi(bar) Identification ft (m) Number (SIN) 12 X 12 (3.6x3.6) 21 7.6 (0.53) 14 X 14 (4.3X4.3) 21 7.6 (0.53) 16 X 16 (4.9X4.9) 21 7.6 (0.53) R7618 18 x 18 (5.5x5.5) 21 7.6 (0.53) 20 X 20 (6.1 X6.1) 23 9.2 (0.63) • Model F1 Res 30, 49, 58 & 76 CCP Pendent 2 5/16" DIA. -------+-2 5/8" {66.7mm} DIA. HOLE IN CEILING [58.7mm} -++----------1 CUP CEILING CUP I "x 1/2" REDUCER I 1/4" {31.5mm} , X. FACE OF FITTING j '. '., 0 FACE OF CEILING .. DIMENSION "A" .r-~~~==Fi -f COVER ADJUSrMENr I HEIGHT I J 5/16" DIA 1 J5FG040 {84. Imm} F1 RES 30, 49, 58 & 76 CCP PEND. Fig. 3 NOTE: The F1 Res 76 will use a 1" x ¾" reducer. 4. • Model F1 Res 30, 49, 58 & 76 Recessed Pendent / FP CCl'.JNC 1/2• {IJmm} ......_ F'P AIJJUSTIIE.Nr FP push-on/thread-off escutcheon 2 ,~ 0:-l:.'k;'"'"' 2 ,/15• DR ,__ __ (5'1,1rrwr1} __ _, CUP L _J Fig. 4 I• X 1/1• RfDUCCR Technical Data: F1 Res 30 CCP Pendent and Recessed Pendent/ FP Nominal Thread Orifice Size Inch (mm) ½" NPT %.,' (8.2) (R1/o\ Max. Sprinkler Spacing Spmder CCP Terl1l, ~ Rail) Terl1l, ~Inn OF ~ "F °C 155 68 135 57 Max. Pressue psi(IJEI) 175 {12) Max. Spnder Anuert K l..er9ll Terl1l, OF °C 100 38 Fader heh (mm) 2.25 3.0 (57) Sprinkler Identification Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/ FP Nominal Thread Orifice Size Inch (mm) ½" NPT ½/ {11) (R'f?) Max. Sprinkler Spacing Spnder Terl1l, Rail) "F or, 155 68 CCP ~ Max. Terl1l, Pressue ~In] psi(IJEI) "F or, 135 57 175(12) Max. Spnder Anuert K l..er9ll Terl1l, OF or, 100 38 Fader heh (mm) 2.25 4.9 (57) Sprinkler Identification R3516 CCP O t" D t 1p ions a a: "A" Cover Adtstment Inch mm) ½ (12.7) 1/.s (7.9) FP Data "A": FP Position Max. Recessed Min. Recessed "B" CCP Height Inch (mm) '1/.s (24) ¾ (19) "A" Inch (mm) }\'6 (1 1) '%(24) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP Nominal Spmder CCP Max. Max. Spnder Thread Orifice Terl1l, ~ Pressue Anuert K l..er9fl Size Inch Rail) T~ psi Terl1l, Fader heh (mm) (bar) ,___~---< (mm) Max. Sprinkler Spacing 175(12) 5.8 2.25 (57) Sprinkler Identification R3513 Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP Nominal Spmder CCP Max. Max. . Thread Orifice Terl1l, ~ Pressue Anuert K Spmder Size Inch Rail) T~ psi TElfl1l. Fader =) (mm) (bar) 175 (12) 7.6 2.25 (57) R7618 5. · Model F1 Res 44 & 58 HSW Technical Data: F1 Res 44 HSW & HSW/F2 • Model F1 Res 44 & 58 Recessed HSW/F2 F2 escutcheon,½" (13mm) adjustment Escutcheon, F2, Data: Nominal Spnder Max. Max. Spnder Tmad Orifice Tert1l, Pressue Anttrt K l..a1glh Si2e Inch Rana psi Term. Fada' h:h (mm) "f "C (bar) "f "C (mm) ½"NPT ¾' (10) 155 68 175 (12) 100 38 4.4 2.45 (62) (R½) 175 79 150 66 Max. Sprinkler "A" Sprinkler Temp. Flow Sprinkler Ceiling -to-Pressure Spacing Deflector Rating gpm psi(bar) Identification ft(m) lnchlmm) OF(OC) (Lpm) Number (SIN) 12 X 12 (3.6x3.6) 155 (68) 175 /79) 12 (45.4) 7.5 (0.52) 14 X 14 (4.3x4.3) 155 /68) 175 {79) 14 (53.0) 10.2 (0.71) 16 X 16 (4.9x4.9) 4 -6 155 /68) 175 (79) 16 (60.6) 13.3 (0.92) 16 X 18 {4.9x5.5) (101-152) 155 /68) 175 (79) 18 (68 1) 16.8(1.16) 18 X 18 (5.5x5.5) 155 /68) 175 (79) 19 (72.0) 18.7 (1.29) 16 X 20 (4.9x6.1) 155 (68) 175 179) 23 (87.1) 27.4 (1 89) R3531 12 X 12 (3.6x3.6) 155 {68) 175 {79) 14 (53.0) 10.2 (0.71) 14 X 14 (4.3X4.3) 155 {68) 175 /79) 16 (60.6) 13.3 (0.92) 16 X 16 (4.9x4.9) 6 -12 155 {68) 175 (79) 17 (64.4) 15.0 {1.04) 16 X 18 (4.9x5.5) ( 152-305) 155 /68) 175 /79) 20 (75.7) 20.7 (1.43) 16 X 20 (4.9x6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1.89) 6. ... Technical Data: F1 Res 58 HSW & HSW/F2 Escutcheon, F2, Data: Nominal SpYi<ler II/lax. II/lax. SpYi<ler 1head Orifice TerJll. Pressue Antirt K l..er9f1 Si2e Inch Rahl psi Terro. Pca:lr' nil (mm) "f 'C (bar) "f 'C (mm) Adjustment Face of Fitting Type In to wall F2 ½"NPT ½' (13) 155 68 175(12) 100 38 5.8 2.45 (62) (R½) 175 79 150 66 Max. Sprinkler "A" Sprinkler Temp. Flow Sprinkler Ceiling-to-Pressure Spacing Deflector Rating gpm psi (bar) Identification ft(m) Inch mm OF(OC) (Lpm) Number (SIN) 12 X 12 3.6x3.6 155 68 14 X 14 4.3X4.3 155 68 16 X 16 4.9X4.9 4-6 155 68 (101-152) 16 X 18 4.9X5.5 155 68 16 X 20 4.9x6.1 155 68 R3533 12 X 12 3.6X3.6 155 68 14 X 14 4.3X4.3 6-12 155 68 16 X 16 4.9X4.9 (1 52-305) 155 68 16 X 18 4.9x5.5 155 68 7. Technical Data: F1 Res 44 SWC Nominal Spmder CoverT001). Tm!ad Orifice T001). Rai,g Size Inch ~ (nm) 'F 'C 'F 'C ½"NPT ½' (10) 155 68 135 57 (R½) Max. Sprinkler "A" Flow Ceiling-to-Pressure Spacing Deflector gpm psi (bar) ft(m) Inch mm (Lpm) 12 X 12 3.6X3.6 13 49.2 14 X 14 4.3x4.3 14 53.0 16 X 16 4.9x4.9 4-6 17 64.3 (101-152) 19 71.8 16 X 18 4.9x5.5 16 X 20 4.9x6.1 23 87.1 12 X 12 3.6x3.6 14 52.9 14 X 14 4.3X4.3 6 -12 15 56.7 16 X 16 4.9x4.9 (152-305) 18 68.1 16 X 18 4.9x5.5 20 75.6 r I I/•• {.Jl.75mm] ltlo1t1'mum ----~ ,r to 12" {101.60mm To J04.80mm] r:o;:,,o~~~;e,,. 1 • X 1/2"' Rtlduct1r R.commendod d"-" ·-r --, Wolf HO,. 2 ,/16• • • • 2 5/8" [58.74mm} I --+·-· {66.68mm] Dia. j : (]io. i \._ : /-.. _,!.... ...... IJ!JF001 :S 5/16" {84. 14mm} Oi'o, i----1-I 21/:S2" [42.07mm} 1/2" {12. 70mm] Adju$/mtHtt f1 RES 44 SWC Fig. 5 Max. Max. Spmder Pressue ArmientT001). K l..en¢I psi Fa:::tor n:h (bar) 'F 'C (mm) 175 (12) 100 38 4.4 2.45 (62) Sprinkler Identification Number (SIN) R3531 8. 2. · Model F1 Res 40 HSW 135FG05 Fig. 6 · Model F1 Res 40 Recessed HSW/F2 F2 escutch_eon, ½" (13mm) adJustment FACE: OF AmNG ro WALL DIMENSION 2 I/•" HOLE: O<A. {57.2mm) TURN COLLAR UNrlL rlGHr AGIJNSr SPRINKLER WRENCH BOSS. l,J!JFCt>6-C ,_.... _ _,_ I 1/4 • MIN, [Jt.Bmm} rrX!~1 grfa/.;gr~ ~ DIMENSION ll I jiiZi=-11" 2 27/J2" DIA {72.2mm} ~ 1/2" {IJmm} ADJUSIJ,/£:Nr l F1 RES 58. 44 & 40 HSW /F2 Fig. 7 Technical Data: F1 Res 40 HSW & HSW/F2 Escutcheon F2 Data: Nominal Spn<ler Max. Max. Spn<ler TITead Orifice Terrp Pressl.re Arrbiert K Lenglh Size Inch Ralila psi Ten Factor heh (mm) "f "C (bar) "f "C (mm) Type F2 ½"NPT ¾' (10) 155 68 175(12) 100 38 4.0 2.45 (62) (A½) 175 79 150 66 Max. Sprinkler "A" Sprinkler Temp. Flow Sprinkler Ceiling -to-Pressure Spacing Deflector Rating gpm psi (bar) Identification ft(m) Inch mm OF(OC) (Lpm) Number (SIN) 12 X 12 3.6X3.6 155 68 175 79 13 49.0 10.6 0.73 14 X 14 4.3X4.3 155 68 175 79 16 60.5 160 1.10 16 X 16 4.9x4.9 155 68 17 64.3 18.1 1.24 16 X 16 4.9x4.9 4-6 175 79 18 68.1 20.2 1.39 (101-152) 16 X 18 4.9X5.5 155 68 175 79 20 75,7 25.0 1.72 R3538 18 X 18 5.5X5.5 155 68 175 79 22 83.3 30.2 2.08 16 X 20 4.9x6.1 155 68 175 79 23 87.0 33.1 2.28 12 X 12 3.6x3.6 155 68 175 79 13 49.0 10.6 0.73 14 X 14 4.3X4.3 6 • 12 155 68 175 79 17 64.3 18.1 1.24 (152-305) 16 X 16 4.9x4,9 155 68 175 79 20 75.7 25.0 1.72 9. Finishes<11 Standard Finishes Sprinkler F1 ,F2,FP Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Brighi Chrome Plated Chrome White Polyester White Painted Coated Soecial Aoolication Finishes Sprinkler F1 , F2, Cover Plates Escutcheons Bright Brass Bright Brass Bright Brass Black Plated Black Plated Black Plated Black Paint Black Paint Black Paint Off White Off White Off White Satin Chrome Satin Chrome Satin Chrome <•> Other finishes and colors are available on special order. Consult factory for details. Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Maintenance I Model F1 Res 30, 49, F1 Res 58, F1 Res 76, F1 Res 44 and F1 Res_ 40 Sprinklers should be inspected quarterly, and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, ~monia or any other cleaning fluids. Remove dust by_ using a _soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than fact?ry applied) or damaged i~ any way. A stock of spare sprinklers should be maintained to allow quick ~eplace_ment o! damaged or operated sprinklers. Prior to 1nstallat1on, ~prinkle~s should remain in the original cartons and packaging until _used. This will minimize the potential for da_mage to spnnkl_ers that could cause improper operation or non-operation. Model F1 Res 30, 49 & 58 Pendent Sprinkler Specifications · Sprinklers shall be [cULus Listed] [New York City MEA Approved (25_8-93-E)] low flow residential pendent spnn~lers engineered to provide a minimum design d~nsIty of 0.05 gprryf over the listed coverage area. Listed flows as spec1f1ed by the manufacturer's technical data sheet~ are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation I standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [ 4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring I washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome-plated ] [White I Polyester] [Special finish-specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 30, 49 & 58, SIN R3511, R3516 & R3513 (Bulletin 135). 10. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish Model F1 Res 49 & 58 Recessed Pendent/F1, Model F1 Res 30, 49 & 58 Recessed Pendent/F2 Model F1 Res 30, 49 & 58 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen_dent sprinklers engine~red to provide a minimum d_es1gn density of 0.05_ 9pm/ft over the listed coverage area. Listed flows as spec1f1ed by the manufacturer's technical ~ata she~ts are to be use~. Residential sprinklers shall be installed In conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings h_aving a pitch from [ 4/12] to [8/12], the sprinklers sh~II be listed for such use. Deflector-to-ceiling distance listing shall be 1" to 8" maximum. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extrude~ or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9_ & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish-specify]. Recessed escutcheon assembly shall be a steel, two-piece es~utcheon [with ½" adjustment (Model F2)] [with ¾" a~Justf;,lent. (Model F1)] [ of push-on and thread off design with ½ adJustment (Model FP)]. Standard finish shall be [brass][bright chrome] [w hite painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 3.0, 49 & 58 Recessed Pendent/F1] [Model F1 Res 30, 49 & 58 Recessed Pendent/F2] [Model F1 Res 30, 49 & 58 Rece~sed Pendent/FP] SIN R351 1, R3516 & R3513 (Bulletin 135). Model F1 Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [ cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers eng ineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [ 4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C). A plastic protective cap shall be p rovided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate fini sh: [White] [Custom Color-specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 30, 49 & 58 CCP, SIN R351 1, R3516 & R3513 (Bulletin 135). Model F1 RES 40 and F1 Res 44 Horizontal Sidewall Residential Sprinkler Specifications Model F1 Res 40 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineere9 to provide a minimum design density of 0.05 gpm/ft over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch from [ 4/12] to [8/12), the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [1 55°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.0 (57.1 ). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish-specify]. Residential horizontal sidewall sprinklers shall be Reliable Model F1 Res 40, SIN R3538 (Bulletin 135). 11. Model F1 Res 40 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 40 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish-specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 40/F2, SIN R3538 (Bulletin 135). Model F1 Res 44 Horizontal Sidewall Sprinkler Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch from [ 4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a½" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville.spring washer with I top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [1 75°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.4 (62.8). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish-specify]. Residential horizontal sidewall sprinklers shall be Reliable Model F1 Res 44, SIN R3531 (Bulletin 135). Model F1 Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 44 horizontal sidewall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 44/F2, SIN R3531 (Bulletin 135). Model F1 Res 76 Pendent Sprinklers shall be [ cULus Listed] low flow residential pendent sprinklers engineere,Q to provide a minimum design density of 0.05 gpm/ff over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish-specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, Model F1 Res 76 Recessed Pendent/FP Sprinklers shall be [ cULus Listed] low flow residential recessed pendent sprinklers engineer~d to provide a minimum design density of 0.05 gpm/ft over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7 .6. Standard f inish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½" adjustment (Model F2)] [with ¾" adjustment (Model F1 )] [of push-on and thread off design with ½" adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 76 Recessed Pendent/F1] [Model F1 Res 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model F1 Res 76 CCP Pendent (Concealed) Sprinklers shall be [ cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm/tt2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a¾" NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 76 CCP, SIN R7618 (Bulletin 135). The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliablel The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address a\ Recycled W Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 06/08 PIN 9999970235 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 510 CPVC-STEEL-COPPER HANGER SIZE -3/4" thru 3" pipe. MATERIAL -Carbon Steel. FINISH -Mil. Galvanized. LISTING/APPROVAL- c@us 203 -EX 4231, EX 2551 e, FUNCTION -To suppo1t horizontal piping -CPVC, Copper or Steel. Hanger in listed mounting positions -Top, Bottom or Side. Also, provides stability on vertical piping. INSTALLATION -PerNFPA 13, 13R, 13D and CPVC manufacturers instructions on top, bottom or side of building element. Space by pipe type. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS -UL Listed per NFPA 13 in WOOD: 3/4" -3" CPVC pipe -#905 screw -no pre-drill. 3/4" -3" Copper pipe -#905 screw -no pre-drill. 3/4" -3" Steel pipe -1/4"xll/2" lag screw -no pre-drill. in STEEL -min. I 8 GA. 3/4" -3" CPVC pipe -1/4" or #14 Tek Screw. 3/4" -3" Copper pipe -1/4" or #14 Tek Screw. 3/4" -3" Steel pipe -J /4" or# I 4 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw has 5/16" hex head -included. ORDERING -Part # and pipe size. *CAN ALSO BE USED TO REPLACE -#500 Pipe Strap #520 Tin Strap o Hanger 0 .__o___,=-~" Stabilize -Only Specific AFCON products are exclusively designed to be com~liblc ONLY with other AFCONproducts including parts and fasteners. resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty res1riction will apply. OISCLAIJ\.t"ER -AFCON will NOT warrant against the failure of its products when used in combination with other products. parts or systems not manufactured or sold by AFCON. A FCON shall NOT be liable under 3ny circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind. including but not limired to loss of business or profit, when non-AFCON products have been, or are used. 2/08 P.O. Box 3365 South El Monte, CA91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 511 SIDE MOUNT CPVC -COPPER HANGER SIZE -3/4" thru 2" pipe. MATERIAL-Carbon Steel. FINISH -Mil. Galvanized. LISTING/APPROVAL- C) c@us 203 -EX 4231, EX 2551 FUNCTION -Hanger on CPVC and Copper pipe. INSTALLATION -Per NFPA 13, 13R, 13D and CPVC manufacturers instructions on top or bottom of beam. Space by pipe type SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS -UL Listed per NFPA 13. in WOOD: 3/4" -2" CPVC pipe -#905 screw -no pre-drill. 3/4" -2" Copper pipe -#905 screw -no pre-drill. in STEEL-min. 18 GA. 3/4" -2" CPVC pipe -1/4" or # 14 Tek Screw. 3/4" -2" Copper pipe -1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw has 5/16" hex head -included. ORDERING -Part# and pipe size. () Hanger -Wood Stud ~ ___ 11 II II II ---IJ--1---<U----- Side View -For Drawings Below Hanger -Metal Stud Specific A.FCON products are exclusively designed to be compatible ONLY with other AFCON products including pans and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be ad\·istd the following warranty restriction will apply. DISCLAIMER ~ AFCONwill NOT warrant against the failure of its products when used in combination with otller products. parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non•AFCON products have been, or are used. 2/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 513 CPVC-STEEL-COPPER HANGER SIZE -3/4" thru 2" pipe. MATERIAL -Carbon Steel. FINISH -Mil. Galvanized. LISTING/APPROVAL- c@.. 203 -EX 4231, EX 2551 FUNCTION -To support horizontal piping -CPVC, Copper or Steel. Tab up = Hanger. INSTALLATION -Per NFPA 13, l 3R and 13D on side or top of beam. Space by pipe type. SPECIAL NOTE: When lnstaUiog on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS -UL Listed per NFPA 13. in WOOD: 3/4" -2" CPVC pipe -#905 screw -no pre-drill. 3/4" -2" Copper pipe -#905 screw -no pre-drill. 3/4" -2" Steel pipe -1/4"xl 1/2" lag screw -no pre-drill. FEATURES * Offset edge eliminates abrasion. * Required AFCON#905 screw has 5/16" hex head -included. ORDERING -Part # and pipe size. Hanger Specific A FCON products arc exclusively designed to be corn~tiblc ONLY with other A FCON products including parts and fasteners. resulting in a hstC":d sway brace. restrainer or hanger assembly. Be advlud the following warranty rcs1riction will ap11ly. DISCLAIM£R -A FCON will NOT warront ago inst the failure of its produces when used in combination wi1h other products, paru or systems not manufactured or sold by AFCON. A FCON shall NOT be liable under any circumstances whatsoever for any direct or ind ire-cl, incidental or consequential damages of any kind, including but nol limited to loss of business or profit, when non•AFCON products have been. or arc used. 2/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 514 OFFSET CPVC HANGER SIZE -3/4" thru 3"pipe. MATERIAL -Carbon Steel. FINISH -Mil. Galvanized .. LISTING/APPROVAL- c@us 203 -EX 4231, EX 2551 PATENT -No. 6,648,278. FUNCTION -3/4"-2" Hanger/restrainer for horizontal CPVC, Copper or Steel pipe. Listed hanger/restrainer in all 3 mounting positions, i.e. vertical surface and both top and bottom of horizontal surface. Provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Size 2 ½" Hanger for horizontal CPVC pipe. Listed hanger in all 3 mounting positions. Size 3" i.e. vertical surface and both top and bottom of horizontal surface. Hanger for horizontal CPVC pipe in two mounting positions, side and bottom. i.e. vertical surface and bottom of horizontal surface. Stabilizes vertical piping by providing horizontal restraint. INSTALLATION -PerNFPA 13, 13Rand 13D. t Space by pipe type. Install on wood, concrete or steel -See Drawings. Snap over pipe then squeeze strap back allowing pipe to slide freely. When #905 threads are exposed in wood, install #906 backing nut. SPECIAL NOTE: When instolling on CPVC sprinkler system pipe: --Listed Restraint Verify that all assembly components arc cleaned of any surface oil. FASTENERS -UL Listed per NFPA 13 WOOD -3/4" -3" CPVC pipe -#905 screw-no pre-drill. 3/4" -2" Copper pipe -#905 screw-no pre-drill. 3/4" -2" Steel pipe -l/4"xl 1/2" lag screw -no pre-drill. Thru 5/8" gypsum board -1/4" x 2" lag screw. STEEL-min. 18 GA. -3/4" -3" CPVC pipe -1/4" or #14 Tek Screw. 3/4" -2" Copper pipe -l/4" or #14 Tek Screw. 3/4" -2" Steel pipe -1/4" or #14 Tek Screw. CONCRETE: Required minimum load each fastener= 5(wt)+ 250/bs. 2 FEATURES * 1 l/2" Offset -loose fit allows pipe to slide. * 3/4" and I" pipe size made with common center-line. * Patented design for superior strength. * Offset edge eliminates abrasion. * AFCON #905 screw has 5/16" hex head -included. ORDERING -Part # and pipe size. AFCON #906 backing nut sold separately. 3/4" thru 2" v' I . "I> ./> _t_ Listed Restraint 314" thru 2" SpocificAFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners. resulting in a listed sway brace, restrainer or hanger assembly, Be advised the following warranty restriction will apply. DISCLAIMER. AFCON will NOT warrant against the failure or its products when used in combination with other products. pans or systems not manufactured or sold by A FCON. A FCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 6/08 Pipe Manufactured for Viking SupplyNet by Viking Plastics, LLC (Huntsville, Alabama USA.) Size I Part Number 3/4" 34PIPE 1· lPIPE 1-1/4" 114PIPE 1-1/2" 112PIPE 2· 2PIPE 2-1/2" 212PIPE 3· 3PIPE BlazeMaster® CPVC fittings are manufactured/supplied for Viking SupplyNet by NIBCO, Inc. Standard Fittings Tee Size I Part Number 3/4" VS0ll-007 1. V5011 -010 1-1/4. VS0ll-012 1-1/2" VSOll-015 Reducing Tee Size I Part Number 3/4"x3/4"x1" V5011R-102 1 "x3/4"x3/4' V5011 R-125 1 "x3/4"x1 • V5011R-126 1 "xl "x3/4" V5011 R-131 l-1/4"x1 "x3/4" V5011 R-157 1-1/4"x1 "xl • V5011 R-15B 1-1/4"x1 "xl-1/4" VSOllR-159 1-1/4"x 1-1/4"x3/4" VSOllR-167 1-1/4"x1-1/4"x1" VS011 R-168 1-1/4"x1-1/4"x1 -1/2" VSOllR-169 1-1/2"x1-1/4 "x3/4 • VSOl lR-201 1-1/2"x1-1/4"x1" V5011 R-202 1-1/2"x 1-1/2"x3/4 • VS0llR-210 1-1/2"x1-1/2"x1" V5011 R-211 I Bag Qty 240 ft 150 ft 105 ft 75 ft 60 ft 30 ft 15 ft I Box Qty Size I Part Number I Box Qty 250 Tee <continued) 100 2· VSOll-020 2 25 2-1/2" V5011-025 1 25 3• VSOll-030 1 I Box Qty Size I Part Number I Box Qty 10 Reducing Tees <continued> 100 1-1/2"x1-1/2"x1-1/4" V5011 R-212 5 10 1-1/2"x 1-1/2"x2" VS011 R-213 s 100 2"x2"x3/4" V5011R-248 2 5 2"x2"x1· V5011 R-249 10 25 2"x2"x1-1/4" V5011 R-250 2 5 2·x2·x 1-1/2" V5011 R-251 2 25 2-1/2"x2-1/2"x 1 • V5011R-2B9 1 25 2-1/2"x2-1/2"x1-1/4 • V5011R-290 1 5 2-1/2"x2-1/2"x 1-1/2" VSOllR-291 1 5 2-1/2"x2-1/2"x2" VSOllR-292 1 5 3"x3"x 1-1/2" VSOllR-337 1 25 3"x3"x2" VSOl lR-338 1 25 3"x3"x2-1/2" VSOllR-339 1 www.vikinggroupinc.com Refer to manufacturer's DESIGN AND INSTALLATION GUIDE for technical specifications and installation instructions. Standard Fittings continued from Page 1 90° Elbow Size I Part Number I Box Qty Size I Part Number I Box Qty 3/4" VS00?-007 250 90° Elbow <continued) 1· VS00?-010 IO0 2-1/2" VS00?-025 1 1-1/4" VS00?-012 25 3· VS00?-030 1 1-1/2" VS00?-015 25 1 • X 3/4" VS00?R-131 100 2" VS00?-020 10 45° Elbow Size I Part Number I Box Qty Size I Part Number I Box Qty 3/4" V5006-007 250 45° Elbow <continued) 1. V5006-010 100 2" V5006-020 2 1-1/4" V5006-012 5 2-1/2" V5006-025 1 1-1/2" V5006-015 5 3" V5006-030 1 Cross Size I Part Number I Box Qty Size I Part Number I Box Qty 3/4" V5035-007 10 Cross (continued> 1" V5035-010 100 2-1/2" V5035-025 4 1-1/4" V5035-012 5 3· V5035-030 1 1-1/2" V5035-015 6 1 ·x1 "x3/4"x3/4" V5035R-131 10 2" V5035-020 4 Coupling Size I Part Number I Box Qty Size I Part Number I Box Qty 3/4" VS0Ol-007 250 Coupling (continued) 1· VS0Ol-010 100 2" VS00l-020 10 1-1/4" V5001-012 25 2-1/2" VS00l-025 1 1-1/2" VS0Ol-015 25 3· VS00l-030 1 Reducing Coupling s,ze I Part Number I Box Qty Size I Part Number I Box Qty 1" X 3/4" VS0OlR-131 IO Reducing Coupling (continued> 1-1/4"x 1· VS00lR-168 5 1-1/2"x 1-1/4" VS00lR-212 5 1-1/2" X 3/4" VS00lR-210 5 2" X 1" VS00l R-249 2 1-1/2" X 1" VS0OlR-211 5 2" X 1-1/2" VS00l R-251 2 Bushing Size I Part Number I Box Qty Srze I Part Number I Box Qty 1"x3/4" V5018-131 100 Bushing <continued) 1-1/4" X 3/4" V5018-167 25 2"x 1-1/4" VS018-250 2 1-1/4"x 1" V5018-168 25 2" X 1-1/2" V5018-251 2 1-1/2" X 3/4" V5018-210 5 2-1/2" X 1-1/4" V5018-290 1 1-1/2" X 1 • V5018-211 25 2-1/2" X 1-1/2" V5018-291 1 1-1/2" X 1-1/4" V5018-212 25 2-1/2" X 2" V5018-292 1 2" X 3/4" V5018-248 2 3" X 2" V5018-338 1 2" X 1" V5018-249 2 3" X 2-1/2" V5018-339 1 Cap Size I Part Number I Box Qty Size I Part Number I Box Qty 3/4" V5017-007 250 Cap <continued> 1· V5017-010 100 2" V5017-020 2 1-1/4" V5017-012 5 2-1/2" V5017-025 1 1-1/2" V5017-015 5 3" V5017-030 1 www.vikinggroupinc.com Sprinkler Head Adapters 1 • X 1/2" V5003SBT-130 50 * Brass starter thread molded into plastic, virtually diminating aoss-threading. Female Sprinkler Head Adapter with Metal Spigot Female Sprinkler Head Adapter with Metal Thread Insert Sprinkler Head 90 with Metal Thread Insert Sprinkler Head Tee with Metal Thread Insert Sprinkler Head Back to Back Cross with Metal Back to Back Tee with Metal Threads Insert Test Plug Size I Part Number I Box Qty 3/4" X 1/2" V50035B1-101 100 1 • X 1/2" V5003SBl-130 50 1" X 3/4" V5003SBI-131 10 3/4" X 1/2" V50032SBl-101 100 1" X 1/2" V50032SBl-130 50 Size I Part Number I Box Qty 3/4" X 1/2" V50073SBl-101 100 1" X 1/2" V50073SBl-130 50 1" X 3/4" V50073SBI· 131 10 1-1/4" X 1/2" V50073SBl-166 5 Size I Part Number I Box Qty rx1·x1· VS012SBl-010 so 3/4"x3/4"x1/2" VS012SBl-101 10 1·x1·x1/2" V5012SBl-130 so 1-1/4"xl -1/4"x1/2" VS012SBl-166 s 1-1/2"x 1-1/2"x1/2" V50125B1-209 5 2"x2"x1/2" VS012SBl-247 2 V50353SBIL-130 1/2"x1/2"x1" 1-1/8" V501133SBIS-075 48 1/2"x 1/2"x1" 1-15/16" V501133SBIL-075 48 ~41d!Mii•f.l·, 1/2" I V450-005 7 50 Size I Part Number I Box Qty Sprinkler Head Tee w/Metal Thread Inserts (continued> 1"x3/4"x1/2" V5012RSBl-124 10 1-1/4"x1 "xl/2" VS012RSBl-156 s 1-1/2"x 1-1/4 ·x 1/2" VS012RSBl-199 s 2"x1-1/2"xl/2" VS012RSBl-237 2 1"x1/2"x1"* V5014RSBl-122' 10 'Socket x FIPT x Socket wwv;.vikinggroupinc.com Transition Fittings Female Adapter with Metal Thread Insert Spigot Female Adapter with Metal Thread Insert Male Adapter with Metal Thread Insert Grooved Coupling Adapter Standard Union Accessories Solvent Cement Dauber Quart VS097Q Pint V5097P Small V5093-S Large V5093-L Size 3/4" 1" 1-1/4" Size 3/4" 1" Size 3/4" 1" 1-1/4" Size 1-1/4. 1-1/2" 2" Size 3/4" 1" 1-1/4" 1-1/2" 12 12 100 100 I Part Number I Box Qty V5003Bl-007 10 V5003BI-010 so V5003BI-012 5 I Part Number I Box Qty V50032BI-007 10 VS0032BI-010 10 I Part Number I Box Qty VS004Bl-007 10 V5004BI-010 10 V5004BI-012 5 I Part Number I Box Qty VS00lG-012 30 VS00l G-015 25 VS00lG-020 15 I Part Number I Box Qty VS033E-007 1 V5033E-010 1 V5033E-012 1 V5033E-015 1 Roller Refer to manufacturer's DESIGN AND INSTALLATION GUIDE for technical specifications and installation instructions. c@us ~@ Size I Part Number I Box Qty Female Adapter w/Metal Thread Inserts (continued> 1-1/2" V5003B1-015 s r V5003B 1-020 2 Size I Part Number I Box Qty Male Adapter w/Metal Thread Inserts <continued> 1-1/2" V5004BI-015 5 2" V5004BI-020 2 Size I Part Number I Box Qty Grooved Coupling Adapter (continued) 2-112· VS00lG-025 10 3" VS00lG-030 8 Size I Part Number I Box Qty Standard Union (continued> 2" 2-1/2" 3· V5033E-020 1 V5033E-025 1 V5033E-030 1 1MIMIIHM·, VS097 I 24 www.vikinggroupinc.com September 2010 No. 113b CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue -Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: .....:Q=u=-=a:.:..rr:...,y.....:C=r-=-ee=k"------------------SR#: _____________ _ PROJECT ADDRESS: PHONE: ( 9Sl) 667-4220 (NP Mechanical, Inc.} Largest Building (ft.2): __________ _ (Assigned upon plan submittal) CITY: Carlsbad FAX NUMBER: ( 951) -=6=67.:....-....:.4=21=-=6'---------- Sprinkled? _____ _ Construction Type: ______ _ SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFO. Water Purveyor: ....,C'-'-ity=.L...Co:..:.f.....:C=a:.:..rl=s=-ba=-d"'---------------------------- location of test (reference map required): __ S=-e=e=-a=-t=t=-ac=h=e=d:.:... ________________ _ TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 94 PSI Hydrant Number (if applicable): New Elevation of test: 114 Feet Main Size: 12 INCH Pressure Zone: 330 Feet Date/lime of Test: I Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 3 750 GPM Residual Pressure 85 PSI At peak demand, this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. However, this flow exceeds the District's maximum pipeline velocity of 10 fps. The maximum fire flow that meets both the velocity and pressure criteria is 3,750 gpm. No specific fire flow was provided for testing. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here:.! Eng. lie. No. (if applicable):~C_6~96_0_6 ______ _ Date: 03/21/2019 I Location N ± Marron Road Legend • w_Hydrant Pipe ZONE -330 -446 -sao Quarry Creek -Fire Flow Analysis