Loading...
HomeMy WebLinkAboutAMEND 2021-0005; T-MOBILE SD06088A; Administrative DeterminationTO OBTAIN LOCATION OF PARTICIPANTS UNDERGROUND FACILITIES BEFORE YOU DIG IN CALIFORNIA (SOUTH), CALL DIG ALERT ® TOLL FREE: 1-800-227-2600 OR Know what's below. Call before you dig. www.digalert.org CALIFORNIA STATUTE REQUIRES MIN OF 2 WORKING DAYS NOTICE BEFORE YOU EXCAVATE ■ ■ • ■ ■ ■ CITY OF CARLSBAD Administrative Permit Case No.Mf'Nb2oJ_I -000,) I "/J,'1 ,, tJ'i s-;,a r;;_-1. Exibit No. -L Date , I SITE NUMBER: SD06088A LAS FLORES ROOFTOP CITY: CARLSBAD SITE NAME: SITE TYPE: SHT DRAWING INDEX REV VICINITY MAP T1 TITLE SHEET 0 T2 GENERAL NOTES 0 , -J2J11• T3 BATTERY SPECIFICATIONS 0 d T4 PLUMBING DIAGRAMS 0 n's Garden A1 SITE PLAN 0 A2 ENLARGED SITE PLAN & EQUIPMENT PLAN 0 A3 ANTENNA PLANS 0 A4 NORTHEAST ELEVATIONS 0 A5 SOUTHEAST ELEVATIONS 0 A6 SOUTHWEST ELEVATIONS 0 A7 NORTHWEST ELEVATIONS 0 D1 DETAILS 0 D2 DETAILS 0 G1 GROUNDING NOTES & PLAN 0 G2 GROUNDING DETAILS 0 E1 PANEL 'A' SCHEDULE AND SINGLE LINE DIAGRAM 0 las Vii ltts de C:ar.lsblld 1 APPROVALS: CODE COMPLIANCE COUNTY: SAN DIEGO JURISDICTION: CITY OF CARLSBAD Algae K110 NORTH ANCHOR SCOPE OF WORK: (RFDSVERSION 10, DATE: 08/27120) MODIFICATION OF AN EXISTING 'T-MOBILE' TELECOMMUNICATION FACILITY CONSISTING OF THE FOLLOWING: EXTERNAL SCOPE (AS DEPICTED IN RFDS): • REMOVE EXISTING AIR21 PANEL ANTENNAS, (2) PER SECTOR, (6) TOTAL • INSTALL AIR6449 PANEL ANTENNA, (1) PER SECTOR, (3) TOTAL • INSTALL AIR32DB PANEL ANTENNA, (1) PER SECTOR, (3) TOTAL • INSTALL RADIO 4415 B25, FOR L 19 AND U19, (1) PER SECTOR, (3) TOTAL • MOVE GSM TO AIR32 DB • INSTALL (1) ENCLOSURE CABINET E6160 AND (1) B160 BATTERY CABINET • PROPOSED 2' EXTENSION OF PARAPET WALL AND FRP SCREEN BOX INTERNAL SCOPE (AS DEPICTED IN RFDS): • ADD (1) BB6630 TO SUPPORT AIR6449 B41 LTE • ADD (1) BB6648 TO SUPPORT AIR6449 N41 NR • UPGRADE AC DISTRIBUTION BREAKER TO 150A • ADD (3) 6x12 HCS 6AWG 40m • ADD (1) VOLTAGE BOOSTER PSU 4813 • ADD (1) NEW IXRe ROUTER PROJECT TEAM SITE ADDRESS: 1088 LAGUNA DRIVE CARLSBAD, CA 92008 PROPERTY OWNER/LESSOR: LAS VILLAS DE CARLSBAD OPERATIONS, LLC DAVID THOMPSON, DIRECTOR OF OPERATIONS (760) 271-8001 ZONING: R-3 JURISDICTION: CITY OF CARLSBAD APPLICANT: PROJECT MANAGER: A&E MANAGER: 'r··Mobile· 10509 VISTA SORRENTO PKWY #206 SAN DIEGO, CA 92121 JESSICA CROSS J5 INFRASTRUCTURE PARTNERS jcross@j5ip.com (858) 752-8152 RAMONA DIPLASIU J5 INFRASTRUCTURE PARTNERS rdiplasiu@j5ip.com (949) 247-7767 ext 159 LATITUDE: 33° 10' 0.61" N (NAD 83) 33.16683750 RF ENGINEER: JUAN CHAVEZ T-MOBILE LONGITUDE: APN: 117' 20' 4139" W (NAO 83) -117 .34482000 155-272-19-00 Juan.Chavez@T-mobile.com CONSTRUCTION MANAGER: KIRT BABCOCK 1--------,-------------,-----------,---------+------------------------------------------1 CURRENT USE: UNMANNED TELECOMMUNICATIONS FACILITY ZONING T-MOBILE Kirt.Babcock@T-MOBILE.com (858) 334-6139 PRINT NAME SIGNA11JRE LAND OWNER: DEVELOP. MANAGER: CONST. MANAGER PROJECT MANAGER: ZONING MANAGER: TMO RF ENGINEER: SAC. REP: CONST. MANAGER GENERAL CONTRACTOR NOTES DO NOT SCALE DRAWINGS SUBCONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. DATE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1. CALIFORNIA BUILDiNG STANDARDS CODE: 2019 TRIENNIAL EDITION OF TITLE 24, WITH AN EFFECTIVE DATE OF JANUARY 1, 2020. PART 1 -CALIFORNIA ADMINISTRATIVE CODE PART 2 -CALIFORNIA BUILDING CODE, BASED ON THE 2018 INTERNATIONAL BUILDING CODE PART 2.5 -CALIFORNIA RESIDENTIAL CODE, BASED ON THE 2018 INTERNATIONAL RESIDENTIAL CODE PART 3 -CALIFORNIA ELECTRICAL CODE, BASED ON THE 2017 NATIONAL ELECTRICAL CODE PART 4 -CALIFORNIA MECHANICAL CODE, BASED ON THE 2018 UNIFORM MECHANICAL CODE PART 5 -CALIFORNIA PLUMBING CODE, BASED ON THE 2018 UNIFORM PLUMBING CODE PART 6 -CALIFORNIA ENERGY CODE PART 7 -VACANT PART 8 -CALIFORNIA HISTORICAL BUILDING CODE PART 9 -CALIFORNIA FIRE CODE, BASED ON THE 2018 INTERNATIONAL FIRE CODE PART 10 -CALIFORNIA EXISTING BUILDING CODE, BASED ON THE 2018 INTERNATIONAL EXISTING BUILDING CODE PART 11 -CALIFORNIA GREEN BUILDING STANDARDS CODE (ALSO KNOWN AS CALGREEN) PART 12 -CALIFORNIA REFERENCED STANDARDS CODE 2. ANSI/TIA-222 (REV H) 3. 2018 NFPA 101, LIFE SAFETY CODE 4. 2019 NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE 5. 2019 NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS PROPOSED USE: ACCESSIBILITY REQUIREMENTS: MANAGER: CHRIS VUONG NO CHANGE THE FACILITY IS UNMANNED AND NOT FOR CONTINUOUS HUMAN HABITATION. DISABLED/CHALLENGED ACCESS IS NOT REQUIRED PER CBC 2019, SECTION 11B-203.4 (LIMITED ACCESS SPACE} STATEMENTS JS INFRASTRUCTURE PARTNERS Cvuong@j5ip.com (858) 205-4150 STRUCTURAL: STRUCTURAL ANALYSIS IS NOT WITHIN THE SCOPE OF WORK CONTAINED IN THIS DRAWINGS SET. FOR ANALYSIS OF EXISTING AND/OR PROPOSED COMPONENTS, REFER TO STRUCTURAL ANALYSIS PROVIDED UNDER SEPARATE COVER. ANTENNA MOUNT ANALYSIS IS NOT WITHIN THE SCOPE OF WORK CONTAINED IN THIS DRAWING SET. FOR ANALYSIS OF ANTENNA MOUNT TO SUPPORT EXISTING AND /OR PROPOSED COMPONENTS. REFER TO ANTENNA MOUNT STRUCTURAL ANALYSIS PROVIDED UNDER SEPARATE COVER. PROPRIETARY INFORMATION: THE INFORMATION CONTAINED WITHIN THIS SET OF DRAWINGS IS PROPRIETARY T-MOBILE. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TOT-MOBILE IS STRICTLY PROHIBITED. T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN 1'S IT RElATES TO T-MOBILE IS STRICTLY PROHIBITED 0 B A REV 2030 MAIN STREET, SUITE 200 IRVINE, CA 92614 SITE NUMBER: SD06088A SITE NAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 12/17/20 100% CONSTRUCTION 11/27 /20 100% CONSTRUCTION 11/16/20 90% CONSTRUCTION DATE DESCRIPTION ,~1_:-_ C"-:-:-;~_ ,..-=~· i'cc-.~ <•.ccs,/ APR 2 0 2021 RD RO AS IT IS A VIOLATION OF lAW FOR ANY PERSON, UNLESS THEi' ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET TITLE TITLE SHEET SHEET NUMBER T1 1. FOR THE FURPOSE OF THIS CONSTRUCTION DRAWING, THE FOLLOWING DEFlNITIONS SHI\LL APPLY CONTRACTOR -GENERAL CONTRACTOR (CONSTRUCllON) AND AW LOVl[R TIER SUBCONTRACTORS. ENGINEER -JS INFRASTRUCTURE PARTNERS OVINER -T -MOBILE \\1RE1ESS 2. CONTRACTOR SHALL VISIT THE CELL SlllE PRIOR TO THE SUBVISSION OF BIDS TO FM11LJARIZE IMTH THE EXISTING CONDITIONS AND TO CONFIRM Tf-\1\T THE WORK CAN BE ACCOMPLJSHED AS SHOWN ON THE CONSTRUCllON DRAWINGS. ANY DISCREPANCY, CONFLICT, OR OMISSION FOUND SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION, PRIOR TO EJD SUBMISSION & PRIOR TO COMMENCEMENT OF ANY WORK THE CONTRACTOR SHAUL BE RESPONSIBLE FOR CORRECTION OF ANY ERRORS, OMISSIONS, OR DISCREPANCIES DISCOVERED AFTER THE COMMENCEMENT OF CONSTRUCTION WHICH HAVE NOT BEEN BROUGHT TO THE ATTENllON OF THE ENGINEER. ANY COSTS INCURRED TO REMEDY THE SITUATION SHALL BE AT THE EXPENSE OF THE CONTRACTOR. THE ENGINEER SHALL /\PPROVE ALL METHODS USED TO CORRECTION THE SITlUATION. 3. ALL MI\TERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE IMTH ALL APPUCABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULAllONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND LITILJTY COMPANY SPECIFICAllONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES A\JD APPLICABLE REGULAllONS. 4. THE COI\ITRACTOR SHALL INSTALL ALL EQUIPMENT AND tJAllERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLIESS SPECIFICALLY STA1t.D OTHERWISE. 5. THE CONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUITS AND OTHER CI\BLES. CONTRI\CTOR SHALL UTILJZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS NECESSARY. 6. THE CONTRACTOR SHALL PROllECT EXIS11NG IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGES SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 7. CONTRACTOR SHALL LIEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MI\TERIALS SUCH AS COAXIAL CABLIES AND OTHER ITEMS REMOVED FROM TrlE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 8. AT ANY TiME DURING THE DURATION OF CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SECURITY OF THE SITE. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. 9. AS MI\Y BE REQUIRED BY THE GOVERNING AGENCY OR PROPERTY OWNER, THE CONTRACTOR SHALL PROVIDE TEMPORARY POl~ER, WATER, OR TOILET FACILl1lES. 10. THE EXISTING CELL SITE IS ASSUMED TO BE IN FULL COMMERCIAL. OPERATION. ANY CONSTRUC110N WORK BY SUBCONTRACTOR SHALL NOT DiSRUPT THE EXISTiNG NORMAL OPERATION. ANY WORK ON EXISllNG EQUIPMENT MUST BE COORDINATED WlllH THE OWNER. ALSO, WORK MAY NEED TO BE SCHEDULED FOR AN APPROPRiAllE MAINTEN/1.t\JCE WINDOW USUALLY IN LOW TRAFFIC PERIODS AFTER MIDNIGHT. 11. THE CONTRACTOR SHALL COMPLY WITH AUL OSHA REGULA1l0NS DURING THE ENllRE CONSffiUCTiON PERIOD. SINCE THE CELL SITE MAY BE ACllVE, ALL SAFETY PRECAUllONS MUST BE TAKEN WHEN WORKING AROJND HIGH LIEVELS OF ELECTROMI\GNETIC RADIATION. EQUIPMENT SHOULID BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULID EXPOSE THE WORKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE REQUIRED TO BE WORN TO ALIERT OF ANY DANGEROUS EXPOSURE LEVELS. 12. THE CONTRACTOR SHALL NOT USE OR INSTALL ANY MATERIAL CONTAINING ASBESTOS OR LEAD PAINT CONTENT. THE USE OF SUCH lvA'ERIAL iS STRICTLY PROHIBITED. 13. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISllNG UTILlllES, WHETrlER OR NOT SHOWN ON PLANS, AND TO AVOID OR PROTECT THEM FROM ANY DAMAGE. /11\rf COSTS INCURRED TO REPAIR LITILlllES D/IJvlAGED DURING CONSTRUCllON SHALL BE AT THE SOLIE COST OF THE CONTRACTOR. TELEPHONE 811 FOR USA DIG ALERT. 14. THE GOVERNING AGENCY MAY REQUIRE A COPY OF THE APPROVED PLAt\JS TO SE KEPT ON S!TE AT ALL llMES. THE CONTRACTOR SHAUL MAKE SUCH A SET AV-6JLABLIE FOR INSPEC1lON AT ALL TIMES. ANY DEVIATIONS FROM THE APPROVED SET SHfil BE DOCUMENTED AND PROVIDED TO THE ENGINEER FOR APPROVAL. THE CONTRACTOR SHALL BEAR THE SOLIE COST TO CORRECT ANY INSTALLA110N IMHICH DE"'1ATES FROM APPROVED PLANS AND IS NOT ACCEPTED BY THE ENGINEER. 15. llHE CONTRACTOR IS SOLELY RESPONSIBLIE FOR ALL MEANS & METHODS, TECHNIQUES, SEQUENCING, AND PROCEDURES REQUIRED TO PERFORM TlHE WORK. ANY ANALYSIS OF THE STRUCTURE UNDER TEMPORARY CONSTRUCTION LOADING CONDITIONS IS OUTSIDE OF THE SCOPE OF THESE DRA:MNGS. THE CONTRACTOR SHOULID EVENLY DISTRIBUllE ANY MI\TERIAL TO BE STORED ON SITE DURING CONSTRUCTION SO THAT THE LOAD DOES NOT EXCEED THE STRUC!7JRES DESIGNED LJVE LOAD; OR PROVIDE TEMPORARY SHORING OR BRACING IN THESE AREAS. 16. DRA\\1NGS ARE NOT TO BE SCALED. DIMENSIONS SHOWN TAKE PRECEDENCE OVER SCALE. 17. ALL NEW COMPONENTS ADD TO THE EXTERIOR OF THE STRUCTURE \\1HICH ARE VISIBLIE FROM PUBLIC VIEW, SHALL BE P-6JNTED TO MI\TCH THE EXISTING CONDl1lONS. 18. ALL DET-6JLS AND NOllES INDICAllED IN THESE PLANS ARE THE MINIMUM REQUIREMENTS. 19. IT MAY BE NECESSARY TO llEMPORARILY RELOCATE, REMOVE, REPLACE, OR WORK /'POUND VARIOL,S ARCHITECTURAL ctATURES, PiPES, FIXTURES, CABUNG, OR OTHER N8N-STRUCTURAL ITEMS IN ORDER TO COMPLIETE THE PROPOSED WORK. CONTRACTOR SHAUL RESTORE THESE ITEMS TO THEIR ORIGINAL CONDiTION AT THEIR EXPENSE UNLESS OTlHERWISE NOTED IN THESE PLANS. GENERAL NOTES ------~----- SYMBOLS I S/G I SOLID GROUND BUS BAR ~ SOLID NEUTRAL BUS BAR =====',A'==SUPPLEMENTAL GROUND CONDUCTOR e,..,...,. 0 1 0 I ........... 0 0 -----0 0 ■ • 2-POLE THERMAL-MAGNETIC CIRCUIT BREAKER SINGLE-POLE THERMAL-MAGNETIC CIRCUIT BREAKER GROUND ROD DISCO\JNECT SWITCH UTILITY METER EXOTHERMIC CONNECTION (CADWELD) TO GROUND RING AND COMPRESSION TO GROUND HALO COMPRESSION, CLAMP, OR DOUBLE HOLE LUG TYPE GROUND CONNECTION LEGEND GROUND ROD WITH ACCESS (TEST WELL) GROUNDING WIRE, DASHED REPRESENTS UNDERGROUND TELEPHONE LINE, DASHED REPRESENTS UNDERGROUND COAXiAL CABLE, DASHED REPRESENTS UNDERGROUND ANTENNA COAX -OH/E -OVERHEAD ELECTRICAL CABLES AGL (E) MIN N.T.S. REF RF T.B.D. TYP EGR AWG MGB EG BCW GEN IGR ABBREVIATIONS ABOVE GRADE LEVEL EXISTING MiN!MUM NOT TO SCALE REFERENCE RADIO FREQUENCY TO BE DETERMINED TYPICAL EQUIPMENT GROUND RING AMERICAN WIRE GAUGE MASTER GROUND BUS EQUIPMENT GROUND BARE COPPER WIRE GENERATOR INTERIOR GROUND RING (HALO) (P) EMT GND GPS GFCI BTCW PROPOSED ELECTRICAL METALLIC TUBING GROUND GLOBAL POSITIONING SYSTEM GROUND FAULT CIRCUIT INTERRUPTER BARE TINNED COPPER WIRE 1. ALL GROUNDING WORK SHALL COMPLY WITH THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE, AS WELL AS WITH ALL LOCAL, STATE, AND NATIONAL CODES, LAWS, AND ORDINANCES APPLICABLE TO GROUNDING WORK. 2 EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION SO AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 4. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION SHALL BE ACCORDING TO SPECIFIC SITE CONDITIONS 5. GROUNDING CONDUCTORS SHALL BE #2 AWG SOLID BARE TINNED COPPER WIRE, UNLESS NOTED OTHERWISE. 6. APPROVED ANTIOXiDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 7. INSTALL GROUND CONDUCTORS AND GROUND ROD A MINIMUM OF 1 '-0" FROM CONCRETE SLAB, FOOTING, OR FENCE. 8. ALL GROUNDi\JG iNSTALLAT!ONS AND CONNECTIONS SHALL BE MADE BY AN ELECTRICAL CONTRACTOR 9. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 10. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING F!TTINGS OR BY BONDING ACROSS THE DISCONTINUITY W!TH 6 AWG COPPER WIRE AND UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 11. GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (E.G., NON-METALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 12. CHEMICAL GROUND SHALL BE XIT, CHEM-ROC, OR APPROVED EQUAL, WHEN REQUIRED. 13. CONNECTIONS TO THE GROUND BARS SHALL NOT BE DOUBLED UP OR STACKED. BACK-TO-BACK CONNECTiCNS ON OPPOSITE SIDES OF THE GROUND BAR ARE PERMITTED. 14. NOTIFY PROJECT MANAGER IF THERE ARE DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SOIL CONDITIONS. 15. ANY EQUIPMENT, BOX, SKID TO BE GROUNDED AND DOES NOT HAVE A DESIGNATED GROUND CONNECTION SHALL BE DRILLED AS NECESSARY TO CONNECT A GROUND WIRE. REMOVE PAINT IN AREA UNDER LUG. APPLY ANTI-OXIDANT COMPOUND AND CONNECT WITH TWO-HOLE, COMPRESSION LUG. 16. ALL NEW GROUNDING SHALL CONFORM WITH 'T-MOBiLE' GROUNDING STANDARDS. GROUNDING NOTES 1. CONTRACTOR SHALL BE RESPONS!SLE FOR PROViOING ALL MEANS AND METHODS TO COMPLETE ALL UPGRADES AS INDICATED IN THIS DOCUMENT. 2. ALL DIMENSIONS, SECTIONS AND DETAILS OF THE EXISTING STRUCTURE ARE INCLUDED FOR INFORMI\TION PURPOSES ONLY. THE CONTRACTOR SHALL VERIFY ALL RELIEVAf'ff INFORMATION PRIOR TO CONSTRUCTION OR FABRICATION. NOTIFY THE ENGINEER-OF-RECORD IMMEDIATELY OF ANY DISCREPANCIES. ALL NEW WORK SHALL ACCOMMODATE EXISTING CONDITIONS. 3. CONTRACTOR IS RESPONSIBLE FOR ERECTING TEMPORARY BARRICADES AND/OR FENCING TO PROTECT THE SAFETY OF THE PUBLIC DURING CONSTRUCTION. THE CONTRACTOR SHALL REMOVE ALL TEMPORARY BARRIERS AND REPAIR ALL DAMAGE TO PROPERTY ON THE SITE CAUSED BY THIS CONSllRUCTION. THE COST OF REPAIR IS THE CONTRACTOR'S RESPONSIBILITY. 4. ALL WORK SHALL BE IN ACCORDANCE WITH APPLICABLE LOCAL STATE, AND FEDERAL REQUIREMENTS. 5. COORDINATE WORK INDICATED ON THESE DRAWINGS WITH THE NEW EQUIPMENT, EXISTING EQUIPMENT, WAVEGUIDE ETC. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICI\TION OF ALL MEASUREMENTS AT THE SITE PRIOR TO ORDERING ANY MAllER!ALS OR CONDUCTING ANY WORK. 7. ALL DETAILING, FABRICATION AND ERECTION OF SlRUCTURAL STEEL SHALL CONFORM TO AISC SPECIFICATIONS AND CODES, LATEST EDillON. 8. CONTRACTOR SHALL COLD-GALVANIZE ALL RAW STEEL AS REQUIRED DURING CONSTRUCTION PROCESS. GENERAL UPGRADE NOTES T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED 2030 MAIN STREET, SUITE 200 IRVINE, CA 92614 SITE NUMBER: SD06088A SITE NAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 0 12/17/20 100% CONSTRUCTION B 11/27 /20 100% CONSTRUCTION A 11/16/20 90% CONSTRUCTION REV DATE DESCRIPTION RD RD AS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEIT TITLE GENERAL NOTES SHEET NUMBER T2 The NSB RED Battery® delivers long life for reliable and unreliable grid conditions. • • • • • • • • • Pure lead electrochemistry greatly increases temp and corrosion resistance, while reducing component aging Thin plates deliver large surface area, high power density and low resistance Design life 15+ years at 20°c (68° F) EUROBAT design life definition : Very Long Life (12+ years) Fast recharging Operating temperature range -40°C to +65'C (-40°F 1o149°F) State-of-the-art automated manufacturing ensures consistency and reliability Sheli liie of up to 24 months Advanced 3 stage terminal design to ensure leak-free TOTA L QUANTITY OF BA TT ERIES IN STALLED AT T-MOB ILE NEW SITE BUILD: FLOODED LEAD ACID NICKEL CADMIUM LITH I U M-1 ON LITHIU M METAL POLYMER VALVE-REG ULATED LEAD AC ID 0 GALLONS 0 GALLONS 0 GALLONS 0 GALLONS SEE TABLE BELOW • • • • operation -brass terminals provide maximum performance High modulus Polyphenylene Oxide (PPO) plastic materials designed to withstand extended elevated operating temperatures and maintain high battery compression essential for reliable operation Non-halogenated, thermally sealed plastic casing Flame retardant (UL 94 VO) and LOI of at least 28% Approved as non-hazardous cargo for ground, sea, and air transport -DOT 49CFR173.159(d), (i) and (ii) NSB 190FT RED Nominal Technical Specifications Dimensions Height 12.6 in Width 4.9 in Length 22 in Weight 123 lbs Electrical Terminal Terminal torque 1 hr capacity to 1.70VPC@ 20/25°C (68/77°F) 3 hr capacity to 1.75VPC@ 20/25°C (68/77°F) 8 hr capacity to 1.75VPC@ 20/25°C (68/77 °F) 10 hr capacity to 1.80VPC @ 20/25°C (68/77°F) Float voltage @ 20/25°C (68/77°F) Impedance (1 Khz) Conductance Short circuit current Operation temperature range Nominal voltage Technical Drawing Female M8 x 1 .25 8.0 Nm (71 in-lbs) 123 / 129 Ah 160 / 164 Ah 183 / 186 Ah 187 / 190 Ah 2.28 I 2.27 VPC 2.8 mO @ 25°C (77°F) 1900 S 5000A -40°C to +65°C 12 V All NorthStar batteries are compliant with: Telcordia SR4228, IEC 60896; Bellcore GR-63-Core, Issue 1; British, German, and Russian 1elecom standards; UL approved and UN2800 certified. Northstar is registered 10 ISO 9001 and ISO 14001. R.AME AHR5TOfi: .t l'lll:SS flfllll'OV/,,1.VECO\'EII / 2:PLCS _____ 560fflm ----- ' 1' ,I ,, Zl.<Jn ' I ii 5:lm"' 2.101 13mm 1151'1 BATTERY IN FORMAT ION (VRLA TYPE BATTERIES) TOTAL# OF BATTERY KWh, Kilowatt-TOTAL STATIONARY BATTERY STATIONARY BATTERY TOTAL ELECTROLYTE AMP-BATTERY STORAGE SYSTEM THRESHOLD TOTAL ELECTROLYTE BY INSTALL STATUS BATTERY MODEL UNITS VOLTAGE (V) hours = STORAGE SYSTEM CODE VOLUME (GALLONS) INSTALLED HOURS (AH) (V* AH)/1000 CAPACITY, QUANTITY, PER CFC 2019 CHECK PER UNIT VOLUME (GALLONS)= (EA) KWh SECTION 1206 PROPOSED NORTHSTAR NSB190FT 12 12 190 2.28 27.36 2.08 24.96 RED CFC 2019 SECTION 1206 TOTAL 12 27.36 70 DOES NOT APPLY 24.96 NOTES: 1. ALL LETTERING SHALL BE CAP ITAL LETTERS ON A CO NTRASTING BACKGROU ND . 2. LETTERS SHALL BE A MI NIMUM OF 7" IN HEIGHT. 3. REFER TO 2019 CFC CHAPTER 12, ENERGY SYSTEM AND SECTION 1206, ELECTRICAL ENERGY STORAGE SYSTEMS 4. SIGN TO BE PLACED ON THE FACE OF THE CABINET. HAZARDOUS MAT ERI ALS WARNI NG SIGN WARNING SIGN T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T -MOBILE ANY USE OR DISC LOSURE OTHER THAN AS IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED 0 B A REV 2030 MAIN STREET, SUITE 200 IRVINE, CA 92614 SITE NUMBER: SD06088A SITE NAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 12/17/20 100% CONSTRUCTION 11/27 /20 100% CONSTRUCTION 11/15/20 90% CONSTRUCnON DATE DESCRIPTION RD RD AS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER TH IS DOCUMENT SHEET TIT LE BATTERY SPECIFICATIONS SHEET NUMBER T3 EXISTING PLUMBING DIAGRAM PROPOSED PLUMBING DIAGRAM ~ . .....-...~ ....... ~---~,..! ~~~ill/-••-·- r~t;iQl~~~•~.¢ -d!a,~~-~1. l!!!w.. """'™ •• .... n,.,ct11tu1';1!11-,hif ;,lL llldl:II' -~. SD06088A 67D02C L600Jpg .I.PXV.IJ&UII = ., 1 S006008A 67D5A997DB Ara:hor.jpg. "" I ,.-,.. I "' I i ! ·-· 2 T 11 11 Mobile 11 T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED 0 B A REV 2030 MAIN STREET, SUITE 200 IRYINE, CA 92614 SITE NUMBER: SD06088A SITENAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 i I 12/17/20 100% CONSTRUCTION 11/27 /20 100% CONSTRUCTION 11/16/20 90% CONSTRUCTION DATE DESCRIPTION RD RD AS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET TITLE PLUMBING DIAGRAMS SHEET NUMBER T4 SITE PLAN (E) BUILDING -----," (E) 'T-MOBILE' ENLARGED SITE PLAN @ (E) BUILDING ------- w z _J >-f--- O:'. w 0... 0 O:'. 0... t= I r I ~ I r I I L KNO\JVLES AVENUE A.P.N.: 155-272-19-00 ~~~~~-r---~ I I I I I I I I I I I I I I I I ~(E) PARKING AREA~ - I I I ~ ' (E) PROPERTY LINE ------~----------------~- ~-(E) BUILDING ---.__ (E) BUILDING --~-~-~ -~-~ -~ --i -~ -~-~ -~-~-~ -~ -- LAGUNA DRIVE ··--·--------- cY DISCLAIMER THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF A CURRENT LAND SURVEY. ALL PROPERTY LINES, EASEMENTS, AND SETBACKS SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION. JS DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINES, EASEMENTS AND SETBACKS. 24"x36" SCALE: 1" = 40' -0" 11"x17" SCALE: 1" = 80'-0" 40 20 0 40' 1 T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED 0 B A REV 2030 MAIN STREET, SUITE 200 IRVINE, CA 92614 SITE NUMBER: SD06088A SITE NAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 12/17/20 100% CONSTRUCTION 11/27/20 100% CONSTRUCTION 11/16/2D 90% CONSTRUCTION DATE DESCRIPTION RD RD AS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET TITLE SITE PLAN SHEET NUMBER A1 ------------- \ \ \ \ \ \ \ ENLARGED SITE PLAN ------------------~--------------------- D D DOD ---- ~(E) BUILDING ROOFTOP~ __ _j_EJ SECTOR B @ 125' AZIMUTH·--- (E) 'T-MOBILE' ,,--- EQUIPMENT AREA EB [ ~(E) BUILDING ROOFTOP~ 24"x36" SCALE: 1/16" = 1 '-0" ■ ■ •~ ■ lrlrl ICILIIJJJ 11"x17" SCALE: 1/32" = 1'-0" 16' 12' 8' 4' O" 0 <r: 0.. w w 0:: 0 0 z I 0 u sj- ~ w -H _j CT] 0 2 I f-- ~ a w a, ~ I r---- ,--~-------------(E) BUILDING 7 II 1!11-...-------------(E) 'T-MOBILE' : ELECTRICAL PANEL ___J L.-----------~~--(E) 'T-MOBILE' TELCO BOX ~ ---------:~~~r[-(E) 'T-MOBILE' IL PANEL A ±5'-0" '/·;kef--(E) 'T-MOBILE' CIENA (E) 'T-MOBILE' GPS ANTENNA (E) 'T-MOBILE' RBS 3106 CABINET -TD REMAIN ---. "•K~,~0 ' '"'"''"' .\:~5'--(E) 'T-MOBILE' RBS 3106 ', CABINET -TO BE REMOVED EXISTING EQUIPMENT PLAN 24"x36" SCALE: 3/8" = 1 '-0" 1i"x17" SCALE: 3/16" = 1'-o" 2' 1' O" 0 <r: 0.. w w 0:: 0 0 z I 0 0 sj- ~ w -H _j [lJ 0 2 I f- ~ N w I '-._./ N ' N I N ' NEW EQUIPMENT PLAN NOTE: 1. ALL ABOVE GROUND AC POWER CONDUIT TO BE RIDGE CONDUIT. r--------------__.:_ __ (E) BUILDING ±5'-o" (E) 'T-MOBILE' GPS ANTENNA (E) 'T-MOBILE' RBS 3106 CABINET W / (N) (2) BB 6630 (E) 'T-MOBILE' DISCONNECT (N) 'T-MOBILE' (1) E6160 (12\ BATTERY CABINET ~ ~-(E) SHRUBS/TREES COVERING 24"x36" SCALE: 3/8" = 1'-0" 11"x17" SCALE: 3/16" = 1'-o" 2' 1' O" 2 3 T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED 0 B A REV 2030 MAIN STREET, SUITE 200 IRVINE, CA 92614 SITE NUMBER: SD06088A SITE NAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 12/17/20 100% CONSTRUCTION 11/27 /20 100% CONSTRUCTION 11/16/2D 90% CONSTRUCTON DATE DESCRIPTION RD RD r,s IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET TITLE ENLARGED SITE PLAN & EQUIPMENT PLANS SHEET NUMBER A2 (N) ANTENNA SCHEDULE POS TECHNOLOGY AZIMUTH RAD CENTER ANTENNA MAKE ANTENNA MODEL RRU MODEL fS A1 U1900, G19DD, o· 37'-9" ERICSSON AIR 21 B2A/B4P -U2100 :<t: A2 L210D o· 37'-9" ERICSSON AIR 32 B4A/B2P - [JC'. 0 r-L70D, L600, N600 (f 37'-0" COMMSCOPE ( 1) RRUS4449 B71 +812 c.., A3 FFHH-65A-R3 w en A4 ------ Bl Ul 900, GI 900, 125" 37'-9" ERICSSON AJR 21 B2A/B4P -U2100 [I] B2 L2100 125" 37'-9" ERICSSON AJR 32 B4A/B2P ' - °' 0 r-[;:l B3 L70D, L600, N600 125 37'-0" COMMSCOPE FFHH-65A-R3 (1) RRUS4449 B71 +B12 en 84 ----- C1 U1900, GI 9D0, 245" 37'-9" ERICSSON AJR 21 B2A/B4P -U21 DO ' p C2 L2100 245° 37'-9" ERICSSON AJR 32 B4A/B2P - [JC'. 0 r-L700, L600, N600 245' 37'-o" RFS APXVAARR 18-43-U-NA20 (1) RRUS4449 B71+B12 c.., C3 w cn C4 ------ (E) 'T-MOBILE' FRP SCREEN ~ WALL, fl'P. 1 PER SECTOR A & B (TOTAL-2) (E) 'T-MOBILE' FRP SCREEN BOX (E) 'T-MOBILE' RFS 6' --+---+--< PANEL ANTENNA TO REMAIN (SECTOR C) (E) FRP SCREEN BOX TO BE INCREASE 2' , n I "St-N X 0 m z w w Ct: u en 0... Ct: LL w _J m 0 2 I ,!-- ~ w ~ 0 I co \ I \ I I \ I \ I 10'-o" (E) 'T -MOBILE' FRP SCREEN WALL -(E) ROOF ACCESS HATCH '---+1----(E) 'T-MOBILE' RRUS4449, TO REMAIN, (1) PER SECTOR (TOTAL-3) □ □ (E) HVAC -~ UNIT, fl'P. □ [J C C (E) CABLE TYPE (N) HYBRID CABUE (2) 7 /8" COAX (5) FIBER JUMPER (1) 3x6 HCS 40m (1) 6x12 HCS 6AWG 40m (4) SUREFUEX 4.3-1D (2) 7 /8" COAX ( 5) FIBER JUMPER (1) 3x6 HCS 40m (1) 6x12 HCS 6AWG 40m ( 4) SU REFLEX 4.3-10 (2) 7 /8" COAX (5) FIBER JUMPER (1) 3x6 HCS 40m (1) 5x12 HCS 6AWG 40m (4) SUREFUEX 4.3-10 ~---(E) 'T-MOBILE' FFHH-65A PANEL ANTENNA TO REMAIN, TYP. 1 PER SECTOR A & B (TOTAL-2) ~---(E) 'T-MOBILE' AIRE21 PANEL ANTNENAS, TO BE REMOVED, (2) PER SECTOR (TOTAL-6) -t;f------~ ,..,.---(E) FRP SCREEN WALL _J TO BE INCREASE 2' _J <C s z w w 0:: u en 0 0... I Ct: LL 01 w _J m __ j§J SECTOR 8 @ 125' AZIMUTH---- 0 2 I ,!-- ~ w ~ _..----(E) BUILDING PARAPET TO BE INCREASE 2' ALL AROUND ~(E) BUILDING ROOFTOP~ (E) BUILDING PARPAET (E) 'T-MOBILE' FRP SCREEN BOX EXISTING ANTENNA PLAN ------· ----- 24"x36" SCALE: 3/8" = 1 '-0" 11"x17" SCALE: 3/16" = 1'-o" 1 (N) ANTENNA SCHEDULE POS TECHNOLOGY AZIMUTH RAD CENTER ANTENNA MAKE ANTENNA MODEL RRU MODEL #'S Al L2100, L1900, o· 39'-4" ERICSSON AIR32 B66A_B2A G1900 - ;i: A2 L2500, N2500 [J 40'-3" ERICSSON AIR5449 B41 - "' 0 r-L700, L500, N500, (1) RRUS4449 B71+885 c.., A3 (f 39'-8" COMMSCOPE FFHH-65A-R3 w L 1900, U1900 (1) RRUS 4415 B25 en A4 ------ 81 l2100, L1900, 125" 39'-4" ERICSSON AIR32 B66A_B2A G19DO - i:o 82 L2500, N2500 125" 40'-3" ' ERICSSON AIR6449 B41 - "' 2 L700, L600, N 600, (1) RRUS4449 B71+B85 [;:l B3 L 1900, U1900 125' 39'-8" COMMSCOPE FFHH-65A-R3 (1) RRUS 4415 B25 1/) B4 ----- Cl l2100, L1900, 245" 39'-4" ERICSSON AIR32 B66A_B2A G1900 - ' ,o C2 L2500, N2500 245" 40'-3" ERICSSON AIR6449 B41 - [JC'. 0 L700, L600, N 500, (1) RRUS4449 871+885 r-c.., C3 245' 38'-8" RFS APXVAARR18-43-U-NA20 w L1900, U1900 (1) RRUS 4415 825 en C4 ------ NOTES: 1. PROPOSED PARAPET WALL EXTENSION WITH ARCHITECTURAL TRIM TO MATCH EXISTING BUILDING. 2. FRP SCREEN BOX, FRP SCREEN WALL AND PARAPET WALL TO BE PAINTED AND TEXTURED ENTIRELY TO MATCH EXISTING BUILDING. ~ (N) 'T-MOBILE' AIR32 PANEL ANTENNA ~TO BE MOUNTED ON (E) PIPE MAST, fl'P. 1 PER SECTOR (TOTAL-3) 2'-6" 144' -0" 1 O' -0" (E) 'T-MOBILE' FRP SCREEN BOX W /2' EXTENSION (E) PARAPET WALL W/ 2' EXTENSION (E) 'T-MOBILE' FRP SCREEN WALL W/2' EXTENSION (E) 'T-MOBILE' RFS +---+--__/ PANEL ANTENNA TO REMAIN (SECTOR C) z 0 [/) z w 1--x w X 0 m z w Wz 0:: 0 O-en en N~no....~ ' Ct: 1--~'IL wx Is~ -_.l N W ~ LO_j ......JN N ~ al ---.___ 03: 2 ti 0.. c2 <( 0.. I 1-- PROPOSED 2' FRP -+-,, SCREEN BOX EXTENSION PER STRUCTURAL 0 I "St- 0 I "St- NEW ANTENNA PLAN \ \ \ I \ I \ I LJ □ I I 3' -6" 3' -0" f f f (N) 'T-MOBILE' RRU4415 B25 TO BE PARAPET WALL MOUNTED ON (N) UNISTRUT. ~ 01 D 1 -(E) ROOF ACCESS HATCH ~---(E) 'T-MOBILE' RRUS4449, TO REMAIN, ( 1) PER SECTOR (TOTAL-3) (E) HVAC -~ UNIT, fl'P. LJ LJ □ 15'-Q" ~-(E) BUILDING PARPAET (E) PARAPET WALL W/ 2' EXTENSION (E) CABLE TYPE (N) CABLE (1) 3x6 HCS 40m (12) FIBER JUMPER (1) 6x12 HCS 6AWG 40m (12) SU REFLEX 4.3-10 (N) (1) 6x12 HCS 6AWG 40m (1) 3x6 HCS 40m (12) FIBER JUMPER (1) 6x12 HCS 6AWG 40m (12) SUREFLEX 4.3-10 (N) ( 1) 6x12 HCS 6AWG 40m (1) 3x5 HCS 40m (12) FIBER JUMPER (1) 5x12 HCS 6AWG 40m ( 12) SU REFLEX 4.3-10 (N) ( 1) 6x12 HCS 6AWG 40m NOTE: 1. NO STEEL, GROUNDING, OR CABLING TO BE ON THE SIDES OR IN FRONT OF ANTENNAS. ~---(E) 'T -MOBILE' FFHH-65A PANEL ANTENNA TO REMAIN, fl'P. 1 PER SECTOR A & B (TOTAL-2) (D I °N ~-PROPOSED 2' FRP SCREEN WALL EXTENSION PER STRUCTURAL _J __J <( 5 z w w z 0::0 u-en Vl z , 0.. ::"" 0 I a:: X __ j_N_J S~C1:°OR 8 LL W a, @ 1250 AZIMUTH---WN (D I °N z 0 [/) z w 1--x w N , -------2 :s I __, LO __, f ti 0... c2 <C 0... _J m---.___ 03: :::,;: I 1-- ~ w ~ PANEL ANTENNA TO BE 1 2 (N) 'T -MOBILE' AIR6449 B41 ~ MOUNTED ON (E) PIPE MAST, Dl Dl fl'P. 1 PER SECTOR (TOTAL-3) (N) 'T-MOBILE' RRU4415 B25 TO BE STACK-MOUNTED ON (4Y6\ (E) PIPE MAST, fl'P. 1 PER~ SECTOR A AND B (TOTAL-2) ~(E) BUILDING ROOFTOP~ ~-PROPOSED 2' PARAPET WALL EXTENSION ALL AROUND PER STRUCTURAL 24"x36" SCALE: 3/8" = 1 '-0" 11"x17" SCALE: 3/16" = 1'-o" 2 T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED 0 B A REV 2030 MAIN STREET SUITE 200 IRVINE, CA 92614 Sl'IE NUMBER: SD06088A Sfl'ENAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 12/17 /20 100% CONSfRUCTION 11/27 /20 100% CQNSfRUCTION 11/16/20 90% CONSTRUCTION DATE DESCRIPTION RD RD AS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET TITLE ANTENNA PLANS SHEET NUMBER A3 I SECTOR "A" I I SECTOR "C'' I T ·Mobile· II (E) 'T-MOBiLE' AIRE21 PANEL ANTNENAS, TO BE REMOVED, (2) (E) BUILDiNG PARAPET, FRP SCREEN AND FRP T-MOBILE WEST LLC PER SECTOR (TOTAL-6) BOX TO BE INCREASE 2' ALL AROUND (E) 'T-MOBILE' FFHH-65A THE INFORMATION CONTAINED IN THIS SET OF PANEL ANTENNA TD REMAIN, (E) 'T -MOBILE' FRP DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO TYP. 1 PER SECTOR A & B SCREEN WALL T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS (TOTAL-2) IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED (E) BUILDING D.. I 0 0::: -LL )'_5') I ~ '. ~ sj-w ;· • ~ • T.O. (E) FRP SCREEN WALL / (E) P~RA~ET WALL$ I ' ~ I I : : I I ' ' ' ' I ' I I I I I I I I ', I ELEV. 40 -0 (A.G.L.) ' I I i I I i I I ', -----------------------j51~~~~ I I I i I I I I I ,, I I -I I L_..J I I I I :1 I ---------------------_ ~(El___l:-MOBILE' PANEL ANTENNAS RAD CEN~ u CJ u ~ ~ 11 I / jL_J ,_ ~ ~ / " C:: a ELEV 37'-9" (A.G.L.) -I ,_ I I .,.di_\ I ' I n---,,__ 2030 MAIN STREET, SUITE 200 ---er nJLr ·-,_ ,_ -,_ ,_ ,_ ,_ :111 n n ,1 i-ro-IRVINE, CA 92614 I I I I ~ ~ rn EE -~ --rn ~ rn ------- I m SITE NUMBER: -rn EE - TT I I I I I I! I rn -~ rn -SD06088A I I ' ---~ I I I SITE NAME: I I LASFLORES -rn -rn -rn ii ii ii ii rn - FINISHED GRADE$ ELEV. 0'-0" (E) 'T -MOBILE' 1088 LAGUNA DRIVE EQUIPMENT AREA CARLSBAD, CA 92008 EXISTING NORTHEAST ELEVATION 24"x36" SCALE: 1/8" 1' o" I"' lllr■ ■ i 1 11"x17" SCALE: 1/16" ~ 1"-0" -~ ■ -8' 6' 4' 2' o" 8' I SECTOR "A" I I SECTOR "C'' I NOTES: 1. PROPOSED PARAPET WALL EXTENSION WITH ARCHITECTURAL TRIM TO (N) 2' BUILDING PARAPET, FRP SCREEN AND FRP- MATCH EXISTING BUILDING. BOX EXTENSION ALL AROUND 2. FRP SCREEN BOX, FRP SCREEN WALL AND PARAPET WALL TO BE PAINTED AND TEXTURED ENTIRELY TO MATCH EXISTING BUILDING. (N) 'T-MOBILE' AIR32 PANEL (N) 'T-MOBILE' AIR6449 B41 PANEL ANTENNA TO BE MOUNTED ON (E) ANTENNA TO BE MOUNTED ON (E) P!PE PIPE MAST, TYP. 1 PER SECTOR MAST, TYP. 1 PER SECTOR (TOTAL-3) (TOTAL-3) (E) 'T-MOBILE' FFHH-65A (E) 'T-MOBILE' RFS 6' 0 12/17/ZD 100% CONSTRUCTION RD PANEL ANTENNA TO REMAIN, PANEL ANTENNA TO REMAIN B 11/27 /2D 10D% CONSTRUCTION RD TYP. I PER SECTOR A & 8 (SECTOR C) TO. (N) PARAPET WALL AND FRP SCREEN WALL""' A 11/15/2D 90% CONSTRUCTION AS (TOTAL-2) ELEV. 42' -0" (A.G.L.) ~ REV DATE DESCRIPTION (E) BUILDING 7 ~ ____ (tl.L]-MOBILE' PANEL ANTENNAS _RAD CENTER$ • ' -! I , ELEV. 40' -3" (A.G.L.) \ D.. ' ________ _/ I I 0 0::: " L,_ I I I I L _ _j I I I I --=-=-=---~ ~-I I I I I I I I I I I 1-z-I I L_~ I I I I I I CD u LJ I I -~ -~ ~---~_(fil_J-MOBILE' PANEL ANTENNAS_,RA~, CENTER$ ~ IL _ _J • I I" I , ELEV. 39 -8 (A.G.L.) I ' / " ~ ' ~ ,_ -,_ ,_ --I r---, ~ _ ~ __ (tl.)_J-MOBILE' PANEL ANTENNAS_ RAD CENTER$ I I ,_ -I -c:11 I ,_ -I . I 1---,.,._ ~ ELEV. 39' -4" (A.G.L.) __.,-61 II Fl . TI J I I I ' 1-,JI. 17 t1 rr-,-.,. ' "-____ _(liLJ-MOBILE' PANEL ANTENNAS ,RA~, CENTER$ I I I ----R ,.___,,...---I ~ ELEV. 38 -8 (A.G.L.) - I rn EE -I -7 rn ~ ~ rn ~ ' I ' I I I I I m - -ill EE -1 I I I I I I ! I rn 0 rn IT IS A VIOLATION OF LAW FOR ANY PERSON, --UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, I ml TO ALTER THIS DOCUMENT I I ~~ I SHEET TITLE ' -rn ill ill = ~ = ~ rn --- NORTHEAST FINISHED GRADE$ ELEVATIONS (E) 'T -MOBILE' ~ ELEV. O' -0" EQUIPMENT AREA SHEET NUMBER A4 NEW NORTHEAST ELEVATION 24"x36" SCALE: 1 /8" 1' o" ~--- ' 2 -cWJI 11"x17" SCALE: 1/16" = 1'-0" s· s· 4' 2' O" 8' I SECTOR "B" I I SECTOR ''A" I T ·Mobile· II (E) 'T-MOBILE' AIRE21 PANEL T-MOBILE WEST LLC ANTNENAS, TO BE REMOVED, (2) PER SECTOR (TOTAL-6) (E) BUILDING PARAPET, FRP SCREEN AND FRP BOX TO BE INCREASE 2' ALL AROUND THE INFORMATION CONTAINED IN THIS SET OF (E) 'T -MOBILE' FFHH-65A DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS PANEL ANTENNA TO REMAIN, IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED TYP. 1 PER SECTOR A & B (E) 'T -MOBILE' FRP (TOTAL-2) SCREEN WALL (E) BUILDING • T.O. (El FRP SCREEN WALL / (E) 'T-MOBILE' PANEL ANTENNAS~ r-7 ,r-1 r7 i ,. ELEV. 40' -0" (A.G.L) '-1" I I I I I ' ' : 11 ---~--~--~--~-------------j51~~u~~ i : i : i: - -------- I i----J!i ::i . -------__ (_ELJ::-MOBILE' PANEL ANTENNAS ,RA~, CEN~ "'--_____ _,____,_ _______ -'-----.L.J ,. ,~ ------------------------ELEV. 37 -9 (A.G L.) -,- Q_ 2030 MAIN STREET, SUITE 200 II r,-. 0 cc IRVINE, CA 92614 -<'If II n _ n n II Jl:;;n,..,.,_ ·~ ,.-r] n n .n.n I I I I z ti' ,_... / / ' -----------------,__ --~ -~ -[D [D -- I --[D ----- ' Sil'E NUMBER: SD06088A - I -! ---rn i ~--------SITE NAME: I LASFLORES ~---,__. rn rn rn ----~ ~ - ' ~ II II FINISHED GRADE..._ ELEV. 0'-0" '~i"' (E) 'T -MOBILE' 1088 LAGUNA DRIVE EQUIPMENT AREA CARLSBAD, CA 92008 24"x36" SCALE: 1 /s" 1 • o" I"' --i 1 -~~~ EXISTING SOUTHEAST ELEVATION 11"x17" SCALE: 1/16" = 1'-0" 8' 5' 4' 2' O" 8' NOTES: (N) 'T -MOBILE' AIR6449 B41 PANEL I I I SECTOR "All I SECTCR "B" 1. PROPOSED PARAPET WALL EXTENSION WITH ARCHITECTURAL TRIM TO ANTENNA TO BE MOU:~TED ON (E) PIPE MATCH EXISTING BUILDING. MAST, TYP. 1 PER SECTOR (TOTAL-3) 2. FRP SCREEN BOX, FRP SCREEN WALL AND PARAPET WALL TO BE PAINTED AND TEXTURED ENTIRELY TO MATCH EXISTING BUILDING. (E) 'T -MOBILE' FFHH-65A PANEL ANTENNA TO REMAIN, TYP. 1 PER (N) 'T-MOB!LE' AIR32 PANEL SECTOR A & B (TOTAL -2) ANTENNA TO BE MOUNTED ON (E) PIPE MAST, TYP. 1 PER SECTOR 0 12/17/20 100% CONSTRUCTION RD (N) 2' BUILDING PARAPET, FRP SCREEN (TOTAL-3) B 11/27 /20 100% CONSTRUCTION RD AND FRP BOX EXTENSION ALL AROUND T.O. (N; PARA.PET WALL AND FRP SCREEN WALL.-, A 11/16/2D 90% CONSTRUCTION AS (E) BUILDING ELEV. 42'-0" (A.G.L.) '-I" REV DATE DESCRIPTION I _ _ __ (N) 'T-MOBILE' PANEL ANTENNAS _RAD C_ENTER $ • -~ ELEV. 40'-3'' (A.G.L.) ' ' I I I 1 !~ ~ ________ ______..,/ I Ii I I L _ _j I I I I 0 --------~ ~ ,I I I I I I I ---=-=-=---~--~ _____ (l!l_'._T-MOBILE' PANEL ANTENNAS_RAD Q_ENTER$ 'L._ _ _j I I L..J I I L~ I I ~ ,_ ' . ' . '. F/_ ,_ ~ , ~ ELEV. 39'-8" (A.G.L) ----~ ' 0 , ~ ____ (tl.LJ-MOBILE' PANEL ANTENNAS ,RA~, CENTER$ ....-ef'n 0 ' II-,,.._ ~ ELEV. 39 -4 (A.G.L.) ,. ,. ,_ nn11rr--....-n1.n.nn ,. ,_ ' ' '...__ ____ ..(~-MOBILE' PANEL ANTE~NNAS ,RA~, CENTER$ I / ..... / -~ ~ ?--~ ,__-----ELLV. 38 -8 (A.G L.) ~ If [D [D --I I [D I --~ ~ I, i! I i ' I ' IT IS A VIOLATION OF l.AW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION I_ I IL -! -OF A LICENSED PROFESSIONAL ENGINEER, - i I rn TO ALTER THIS DOCUMENT. I ~~ ' SHEET TITLE I r---..,_.,-I--rn rn rn ' rn SOUTHEAST ----- I l~,-~I ELEVATIONS "•9ijl FINISHED GRADE$ II II ELEV 0'-0" (E) 'T-MOBILE' EQUIPMENT AREA SHEET NUMBER AS 24"x36" SCALE: 1/8" 1 • o" I"' ....... ; 2 c~--NEW SOUTHEAST ELEVATION 11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4' 2' O" 8' -·------~~~- ~-s_E_cT_o_R_'_'c_" __ I L._l __ s_E_cT_O_R_'_'B_" _ __, (E) 'T-MOBILE' RFS 6' ----- PANEL ANTENNA TO REMAIN (SECTOR C) $ T.O. (E) ,FR\, SCREEN WALL / (E) 'T-MOBILE' PANEL ANTENNAS ELEV. 40 -0 (A.G.L.) (E) BUILDING PARAPET, FRP SCREEN AND FRP BOX TO BE INCREASE 2' ALL AROUND --(E) 'T-MOBILE' AIRE21 PANEL ANTNENAS, TO BE REMOVED, (2) PER SECTOR (TOTAL -6) --(E) BUILDING ~T -MO Bl LE' PAN EL ANTENNAS RAD CENTER __ _r---------,aF!J,,,:Jr'W'sJ.HJ~Jrll.--sJ.HJ~Jrll.--~~!rllf".!JtsU~H,!Aws!J,~N!rilrl!t~HJAwsw,).JrlJ~LJrl.!?-irll~W'iJ,W"lJ~W'iJ,-lr!k,.,,,,.J,s,1Jr~"iWH,1AIJrl.j,~ ELEV. 37'-9" (A.G L.) rn rn rn $ FINISHED GRADE ELEV. 0'-0" EXISTING SOUTHWEST ELEVATION ~_s_Ec_T_o_R_,_·c_" _ __,I '-I __ s_Ec_T_o_R_'_'B_" _ __, T.O. N PARAPET WALL AND FRP SCREEN WALL ELEV. 42'-0" (A.G.L.) (N) 2' BUILDING PARAPET, FRP SCREEN AND FRP BOX EXTENSION ALL AROUND ~-T-M?Bl~E' PANEL ANTENNAS RAD CENTER~ ELEV. 40 -3 (A.G.L.) , "-------------/~ r-;:=:::::=::= ~T-M?Bl~E' PANEL ANTENNAS RAD CENTER__/ // // ELEV. 39 -8 (A.G.L.) , ~'T-M?Bl~E' PANEL ANTENNAS RAD CENTER_// ,/ ELEV. 39 -4 (A.G.L.) / ~ (N) 'T-M?Bl~E' PANEL ANTENNAS RAD _CENTER_// , ELEV. 38 -8 (A.G.L.) $ FINISHED GRADE ELEV. O' -0" NEW SOUTHWEST ELEVATION ---------------------------------------- I I I I I 11 ii ' i' I I I ---(N) 'T-MOBILE' AIR32 PANEL ANTENNA TO BE MOUNTED ON (E) PIPE MAST, TYP. 1 PER SECTOR (TOTAL-3) ,----(N) 'T-MOBILE' AIR6449 B41 PANEL ANTENNA TO BE MOUNTED ON (E) PIPE MAST, TYP. 1 PER SECTOR (TOTAL-3) rn rn --(E) BUILDING rn DJ DJ DJ DJ rn rn rn 24"x36" SCALE: 1/8" = 1'-0" ~ ~-■ --■ -11"x17" SCALE: 1/16" = 1'-0" s· 6' 4' 2· o" NOTES: 1. PROPOSED PARAPET WALL EXTENSION WITH ARCHITECTURAL TRIM TO MATCH EXISTING BUILDING. 2. FRP SCREEN BOX, FRP SCREEN WALL AND PARAPET WALL TO BE PAINTED AND TEXTURED ENTIRELY TO MATCH EXISTING BUILDING. 24"x36" SCALE: 1 /8" = 1 '-o" ~--._,._ 11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4' 2' o" ' 1 8' ' 2 8' T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO T -MOBILE IS STRICTLY PROHIBITED 0 8 A REV 2030 MAIN STREET, SUITE 200 IRVINE, CA 92614 SITE NUMBER: SD06088A SITE NAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 ' 12/17/20 100% CONSTRUCTION 11/27 /20 100% CONSTRUCTION 11/16/20 90% CONSTRUCTION DATE DESCRIPTION RD RD AS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET TITLE SOUTHWEST ELEVATIONS SHEET NUMBER A6 ~-S_EC_T_O_R_'_'A_" -~II'-----_S_EC_T_O_R_'_'C_" -~ (E) BUILDING PARAPET, FRP SCRE BOX TO BE INCREASE 2' ALL ARO $ T.O. (E) ,FRf:'. SCREEN WALL / (E) 'T-MOBILE' PANEL ANTENNAS ELEV. 40 -0 (AG.L.) EN AND UNO $ (E) 'T-M,°Bl~E' PANEL ANTENNAS RAD CENTER--~--------- ELEV. 37 -9 (AG.L.) 0 -I 0 - FRP ~ .. I ';;" ..., re re , " I Ii I I I I I [L I Ii I I I I I oc: I Ii I I I I I LL WI I LJ co I I ~ '---' -w -~ ___,---rr n .. 11nfJ!if'I ' I (F) 'T MOBILF' RFS DANE' --,, -, I L ANTENNA TO REMAIN, TYP. 1 PER SECTOR C (TOTAL-1) (E) 'T-MOBILE' AIRE21 PANEL ANTNENAS, TO BE REMOVED, (2) PER SECTOR (TOTAL-6) I I I I -----,__. ~ -------1111~~~ "--' rn ~ --- $ FINISHED GRADE ELEV. O' -0" EXISTING NORTHWEST ELEVATION (E) 'T-MOBILE' RFS 6' PANEL ANTENNA TO REM PER SECTOR C (TOTAL- AIN, TYP. 1 ) ANTENNA (E) 'T-MOBI LE' 4' PANEL TO BE MOUNTED ON (E) MAST, TYP. 1 PER SECTOR PIPE A &B (TOTAL-2) T.O. N PARAPET WALL AND FRP SCREEN WALL ELEV. 42' -0" (A G.L.) ~'T-MOBILE' PANEL ANTENNAS RAD CENTER~ ELEV. 40'-3" (A.G.L.) , SECTOR "A" 1 ~ -----------,~/ ~l-M,OBl~E' PANEL ANTENNAS RAD CENTER ___/ /, ELEV. 39 -8 (AG.L.) -------------------,,,,------ / / / ~T-M,OBl~E' PANEL ANTENNAS RAD CENTER---"// ,/ ELEV. 39 -4 (AG.L.) / ~ 'T-M,°Bl~E' PANEL ANTENNAS RAD CENTER__/' ELEV. 38 -8 (AG.L.) $ FINISHED GRADE ELEV. 0'-0" NEW NORTHWEST ELEVATION -~~-------------------~---------------------- • • mmmn I DIDilD -I --mll DI I I = = ' ill ill -- SECTOR "c'' ro "' ! : I : I I ' I I I I > I > I I I I I I L_J I I 0 [L L~J : I I -oc: I I LO I LL l_J N~ ~ z -+1 ~ ,... -,... ___....-r Ir i ro .n .n n n r I ~ ~ F -- ' D 11]( ' i , I -, I I ! -I I I 'm m - ill rn --- mm m I - ill mu __ mil D ' ! 1, ' -,'1 ill ill -rn ( ) ' B D G P R PET RP S REEN D " P N 2 UIL IN A A ' F C, AN ,R BOX EXTENSION ALL AROUND (N) 'T-MOBILE' AIR6449 841 PANEL ANTENNA TO BE MOUNTED ON (E) PIPE MAST, TYP. 1 PER SECTOR (TOTAL-3) (N) 'T-MOBILE' AIR32 PANEL ANTENNA TO BE MOUNTED ON (E) PIPC: MAST, TYP. 1 PER SECTOR (TOTAL -3) ,_ I -,_ ,_ ,...--~ ~-----rn c=: --I m ,I) m II .m,• I I ' .. I -ill m IIIlillmm . ' ill ill -ill (E) BUILDING ,_ ,_ ,_ -,_ ~ ,_ - --,_ ,_ --------- m rn rn ! -ill rn ' ill - (E) BUILDING I I 7_ ,_ f 1 I --' ,_ I ,_ m rn rn Im ill rn ill - ~ I I -, ti-- illlfi\l\'--r I ~ --~ ill - I -ill I I ~ ~ ~ -'----' ~ ~ 1 - 24"xJ6" SCALE: 1/8" ~ 1 '-0" I"' --■ --■ -11 "x17" SCALE: 1/16" ~ 1'-0" 8' 6' 4' 2' O" NOTES I 1. PROPOSED PARAPET WALL EXTENSION WITH MATCH EXISTING BUILDING. ARCHITECTURAL TRIM TO PARAPET WALL TO BE EXISTING BUILDING. 2. FRP SCREEN BOX, FRP SCREEN WALL AND PAINTED AND TEXTURED ENTIRELY TO MATCH I I .,_ 7 [ ~ j i/Fltfnr-. ' ~ ~ r---ill ~ m -w -------1' ~ ~ ~ ~ ~ ~ - 24"xJ6" SCALE: 1/8" ~ 1 '-0" I"' --· !MMM• 1'1"x17" SCALE: 1/15" ~ 1'-0" 8' 6' 4' 2' o" ; 1 8' ' 2 8' T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO T-MOBILE IS STRICTLY PRDHIBITED 0 B A REV 2030 MAIN STREET, SUITE 200 IRVINE, CA 92614 SITE NUMBER: SD06088A SITE NAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 12/17/20 100% CONSTRUCTION 11/27/20 I 100% CONSTRUCTION 11/16/2D 90% CONSTRUCTION DATE DESCRIPTION RD RD AS IT IS A VIOLATION DF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT SHEET TITLE NORTHWEST ELEVATIONS SHEET NUMBER A7 PIPE TRANSFER KIT PROVIDED BY MANUFACTURER---~ ANTENNA DOWNTILT MOUNTING KIT-----+~ (N) PANEL ANTENNA-------1----+------i EB (N)/(E) PIPE 2"¢ X 8'-0" STD.--~ ANTENNA MOUNTING DETAIL SCALE NTS. 1 NOTE: 1. USE MANUFACTURER SUPPLIED MOUNTING HARDWARE. (P) SCREWS (4 PER MOUNT), PROVIDED BY MANUFACTURER--~ SXK 125 0246/1, PROVIDED BY MANUFACTURER (TOTAL-2 PER RRU) ------..__ P1007 NUTS WITH SPRING, AS REQUIRED PER EQUIPMENT MANUFACTURE'S SPECIFICATIONS Pl 000 UNISTRUT, OR APPROVED EQUAL, TYP. ---~ RRU MOUNTING DETAIL FIBER JUMPERS TO I ANTENNAS OR RRU'S HCS 6X12 CABLE Ol Ol Ol ' Ol Ol ' :I Ol ~ --1J_ ' ' ; ~ \ ; -_,, ' DC POWER CABLES TO ANTENNAS OR RRU'S 6 PAIRS OF 6 AWG CONDUCTORS REMOTE RADIO UNIT (RRU) SCALE NTS. 5 , JIUII 0 I FIBER SPLICE CONN MOUNT NEW CONNE ECTORS CTOR ACKETS TH TO (E) ANTENNA BR OR PIPE MOUNTS WI GALV. HOSE CLAMP • • • 12 FIBER PAIRS (24 FIBERS), EACH TERMINATED W/ ODC MALE CONNECTOR DIA = 1.38"0 HCS 6x12 CABLE SPECS SCALE NTS. 9 n n 20.6" FRONT 8.6" SIDE ANTENNA SPECIFICATIONS MANUFACTURER ERICSSON MODEL: AIR6449 841 LENGTH: 33.1 IN WIDTH: 20.6 IN DEPTH: 8.5 IN WEIGHT: 104 LBS WEIGHT: 116 LBS W/ CLAMPS 11 ( I ' " ANTENNA SPECIFICATIONS SCALE NTS. NOTE: 1. USE MANUFACTURER SUPPLIED MOUNTING HARDWARE. (N) RADIO, TYP. _____ ____,,, PIPE MOUNT ------------1 (N) MANUFACTURER SUPPLIED HARDWARE, TYP 2 PER UNISTRUT--__,, RRU MOUNTING DET. (STACKED) SCALE NTS. COPPER BRAID--~ COPPER CONDUCTOR-, PVC-NYLON INSULATION PVC SHEATH-------- INNER COVERING, POLYESTER TAPE---_,,. NON-HYGROSCOPIC DUMMY CORES AS NEEDED--- ERICSSON PART NUMBER: UTDC18_500M DIMENSIONS: • OUTER DIA NOlvllNAL: • OUTER DIA MIN: • OUTER D'A MAX: • MIN. AVERAGE JACKET WALL THICKNESS 0.68" (17 3MM) 0.54" (16.2MM) 0.74" (18.SMM) 0.085" (2.16MM) 2 6 (D (D u) j ' 12 g" / FRONT 8 7" ~ 1/2 - SIDE ANTENNA SPECIFICATIONS MANUFACTURER: ERICSSON MODEL AIR 32 82A 866A DUAL BAND LENGTH: 56.6 IN WIDTH: 12.9 IN DEPTH 8.7" IN WEIGHT: 132.2 LBS. TOTAL WEIGHT W/ BRACKET 142.2 LBS. 0 ANTENNA CLAMP KIT [ PRODUCT# SXK 109, W=10 LBS. SUPPLIED BY ERICSSON 0 u) I ' 0 U) TOP ANTENNA SPECIFICATIONS SCALE NTS. 3 NOTE: 1. USE MANUFACTURER SUPPLIED MOUNTING HARDWARE ~ I "'---" , .. ~ lo A •• •C ., °' I I 1CIJ I I I I I E -Sc:i ,_ . '" r@ ' ,--'" .. . ' oC ~H ., " I I I I I I I ,, . .c;,:.-,: ;.._:,.:;r- .. ,. .. , ', BASEBAND 6630 SPECS o I °" I I I ., ., I . . EQUIPMENT SPECIFICATIONS MANUFACTURER: ERICSSON MODEL: BASEBAND 6630 HEIGHT: 1. 7 IN WIDTH: 13.86 IN DEPTH: 19 IN WEIGHT: 14.33 LBS I ,.c '"""'"CSI\UL\lll'SC-IJ.N;,\J , ,>~ @ QQ ll 'l ,I>. 'l I>. "ll\,'12 03g I IBEm' '·:': .'C:C'''''"'· @ 7 ___.-[N) PIPE 2.5 STD MAST OR [E] PIPE SUPPORT RELOCATED 1/2" DIA U-BOLT [NJ ANGLE PER PLAN 8" MIN. f-u w --, m, o, I f-(f) W, O'.'. <( w z 13.2" TOP NEAREST OBJECT 20" MIN. j 20" MIN. ______ J_ FRONT 'f-Ul w O'.'. <( w rz SPECIFICATIONS *KEEP 40" CLEAR FROM FRONT OF RRU MFG: MODEL: HEIGHT: WIDTH DEPTH: ERICSSON 4415 825 14.9 IN 13.2 IN 5.4 IN WEIGHT: 44.1 LBS 5.4'' 14.9" 8" MIN. f-------1 J SIDE (N) 4415 B25 MOUNTED TO ANTENNA PIPE MOUNT--orJ (N) MANUFACTURE SUPPLIED HARDWARE _ __,, PIPE MOUNT, TYP.------, RRUS 4415 B25 SPECIFICATIONS SCALE NTS. NOTE: 1. USE MANUFACTURER SUPPLIED MOUNTING HARDWARE EQUIPMENT SPECIFICATIONS MANUFACTURER: ERICSSON MODEL: BASEBAND 66481.7 IN WIDTH: 13.86 IN DEPTH: 19 IN WEIGHT: 1 4.33 LBS BASEBAND BB6648 SPECS SCALE N.T.S. ♦ EMERSON- Power Protection Cabinet AC & Telc.o Com:bination Part li!llllber: CS7S2-WM$ C11blnll't Conllgundlon Dimensions 60"H X 2S'W X 'IO"D Mabarlal Alumlr1um Ccimlruc:tion -0. '100" min. Waight 150 lb (approoc..) Pailt Pnwriar Goel Paint-Gray Exlsnor F FOOi Daor Coolilllfill.15 SS Hinge, 3 Poot Latdling Hem!le, !111° Wirnl Sop Mo1mlins Wall, !+Frame, and Pad Moonlirtg Opti<JflS Agency Appl'O\/alt UL 001 Dead Fro I'll &Nlk:llboaroo, NEMA fype 3R p.OM1r eemer Dimensions \l<lll>l'lg,:, Amperage Utiily Fault 00-H X 'JS'W X 10"D [approx.) 24W120 \f;aio, s.tgi> Pfw;a 200A Cmrer,t Rating B!il!AIC Tmlll!fer"lypa Sli:le BarMechanlcal lntooook Distribution M Pooilion, 2006. Lead Cer11!!r Genemtor Rooeptacle ~Applo:!1oo.AR20044RS T\ISS MOV only 2001tA per fll'iallf> Teloo Compadmmd: Dimensioos Grounding Equipment Mounting Convenieooe Oullelll TVSS (on 60/!\. 2 p,LI& bra,;ikar) 3ilf'H X 2S'W X 10"[] 11 Posilioo 011111-1.ug. Copper Groul'll!I Bar 111" X 19" Pt,wcod Back Bomd Standard GFCI Duplex Reoe!]tade {lnterior)(on 2(1A, 1 pale. llreaker) (t)TCS-T10S ~ T1 Un,:, Surga SLJPPl'l"=lon 4 8 6AWG DC CABLE SPECS ...,__._...SCA ...... LE---11 O ~SfilIEL TO PIPE MAST DETAIL NTS. I--SCA_LE---111 AC PANEL SPECIFICATIONS NTS. SCALE 12 --NTS. T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN faS IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED 0 B A REV 2030 MAIN STREET SUITE 200 IRVINE, CA 92614 SflE NUMBER: SD06088A SITE NAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 12/17/20 100% CONSTRUCTION 11/27/20 100% CONSTRUCTION 11/16/20 90% CONSIBUCTION DATE DESCRIPTION RD RD AS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER. TO ALTER THIS DOCUMENT. SHEET TITLE DETAILS SHEET NUMBER D1 NOT USED 0 0 CD N ' .I/ f 7 I I 26.00" ENCLOSURE E6160 1 • J • ]o 0 0 ' 0 0 ' CD N 0 Lo\ Ii 0 l ~ 0 SCALE 2 ---N.T.S. E6160 SPECIFICATIONS MANUFACTURER: ERICSSON MODEL: E6160 HEIGHT: 63" WIDTH: 26" DEPTH: 26" WEIGHT: 320 LBS. (SHELL) WEIGHT: 465 LBS. (W/ ACTIVE COMPONENTS) 0 0 0 ' ' 0 0 0 26.00" l ~ PLAN VIEW BOLT HOLE PATTERN 26.00" f . -------'\. 0 0 -tj- 0 0 n (D FRONT VIEW ~ ~-------BASE FRAME ___ ___,, r 26.00" r SIDE VIEW -------'\. 0 0 -tj- ' 0 0 n tD 0 0 CD N • r 26.00" ENCLOSURE B160 PLAN VIEW 26.00" r SCALE N.T.S. D 0 n CD D 0 CD . 3 NOTE: I ***SPECIAL INSPECTION REQUIRED I ' V /[P) EQUIPMENT CABINET ,.,,,,---1 /2"0 HILT! KB-TZ / EXPANSION ANCHORS / [STAINLESS) EMBED=3-1 /4" / (ESR-1917) 0 (1) EA CORNER f--------------'---~ (4) EA UNIT ' ' \ ', ' . ;., .. : ,·, ' ,· / ' ~ EQUIPMENT ANCHORAGE 8160 SPECIFICATIONS (E) 6" CONCRETE PAD (MIN) AT GRADE -V.1.F. SCALE N.T.S. (N) BATTERY CABINET Bl 60 IS REQUIRED WITH EACH NEW E6160 REGARDLESS OF GENERATOR STATUS. MANUFACTURER: ERICSSON MODEL: B160 HEIGHT: 63" ' 0 0 tD N OD r-'- ~ 00 I L ~ WIDTH: 26" DEPTH: 26" WEIGHT: 296 LBS. (134 KG.) (INCL BASE FRAME) MAX WEIGHT: 1,772 lbs. (NORTHSTAR NSB 190FT RED BATTERY, 123 lbs. ea. x 12) 22.05" A . i-..,1 • . 2.9 1H3" ' @ r--- r-'-01 " O'.) O'.) 0 A N 1 :5 -0- OD I-->. . 26.00" l ~ BOLT HOLE PATTERN 26.00" SIDE VIEW 0 0 n CD 0 0 (D FRONTVIEW ~ ~-------BASE FRAME ___ ___,, 4 E6160 SSC CABINET SPECIFICATIONS ..... r-:ct--~E0--t,, 10 B160 BATTERY CABINET SPECIFICATIONS SCALE 12 --1"=1'-0" T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED 2030 MAIN STREET, SUITE 200 IRVINE, CA 92614 SITE NUMBER: SD06088A SITENAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 0 12/17/20 1 DO% CONSTRUCTION B 17/27 /20 1 DO% CONSTRUCTION A 11/16/2D 9D% CONSTRUCTION REV DATE DESCRIPTION RD RD AS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET TITLE DETAILS SHEET NUMBER D2 GROUNDING NOTES: 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALLATION REQUIREMENTS AND CONSTRUCTION ACCORDING TO SITE CONDITIONS. 2. ALL GROUNDING CONDUCTORS: #2 AWG SOLID BARE TINNED COPPER WIRE UNLESS OTHERWISE NOTED. 3. GROUND BAR LOCATED IN BASE OF EQUIPMENT WILL BE PROVIDED, FURNISHED AND INSTALLED BY THE VENDOR. 4. ALL BELOW GRADE CONNECTIONS: EXOTHERMIC WELD TYPE, ABOVE GRADE CONNECTIONS: EXOTHERMIC WELD TYPE. 5. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM BELOW THE FROST LINE. 6. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1 '-□" FROM EQUIPMENT CONCRETE SLAB, SPREAD FOOTING, OR FENCE. 7. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED SPRAY. 8. GROUND BARS: A) EQUIPMENT GROUND BUS BAR (EGB) LOCATED AT THE BOTTOM OF ANTENNA POLE/MAST FOR MAKING GROUNDING JUMPER CONNECTIONS TO COAX FEEDER CABLE SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. JUMPERS (FURNISHED BY OWNERS) SHALL BE INSTALLED AND CONNECTED BY ELECTRICAL CONTRACTOR. 9 ALL GROUNDING INSTALLATIONS AND CONNECTIONS SHALL BE MADE BY ELECTRICAL CONTRACTOR. 10. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING. 11. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED (2 MINIMUM). 12. IF EQUIPMENT IS IN A C.L. FENCE ENCLOSURE, GROUND ONLY CORNER POSTS AND SUPPORT POSTS OF GATE. IF CHAIN LINK LID IS USED, THEN GROUND LID ALSO. 13. GROUNDING AT PPC CABINET SHALL BE VERTICALLY INSTALLED. 14. ALL GROUNDING FOR ANTENNAS SHALL BE CONNECTED SO THAT IT WILL BY-PASS MAIN BUSS BAR. 15. ALL EMT RUNS SHALL BE GROUNDED AND HAVE A BUSHING, NO PVC ABOVE GROUND. 16. USE SEPARATE HOLES FOR GROUNDING AT BUSS BAR. NO "DOUBLE-UP" OF LUGS. 17. POWER AND TELCO CABINETS SHALL BE GROUNDED (BONDED) TOGETHER. 18. NO LB'S ALLOWED ON GROUNDING. 19. PROVIDE STAINLESS STEEL CLAMP AND BRASS TAGS ON COAX AT ANTENNAS AND DOGHOUSE. 20 ALL ELECTRICAL AND GROUNDING AT THE CELL SITE SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 780 (LATEST EDITION), AND MANUFACTURER SPECIFICATION. 21 IF THE AC PANEL IN THE POWER CABINET IS WIRED AS SERVICE ENTRANCE, THE AC SERVICE GROUND CONDUCTOR SHALL BE CONNECTED TO GROUND ELECTRODE SYSTEM. WHEN THE AC PANEL IN THE POWER CABINET IS CONSIDERED A SUB-PANEL, THE GROUND WIRE SHALL BE INSTALLED IN THE AC POWER CONDUIT. THE INSTALLATION SHALL BE PER LOCAL ANO NATIONAL ELECTRIC CODE (NFPA-70). 22 EXOTHERMIC WELDING IS RECOMMENDED FOR GROUNDING CONNECTION WHERE PRACTICAL. OTHERWISE, THE CONNECTION SHALL BE MADE USING COMPRESSION TYPE-2 HOLES. LONG BARREL LUGS OR DOUBLE CRIMP CLAMP "c" CLAMP. THE COPPER CABLES SHALL BE COATED WITH ANTIOXIDANT (COPPER SHIELD) BEFORE MAKING THE CONNECTIONS. THE MANUFACTURER'S TORQUING RECOMMENDATIONS ON THE BOLT ASSEMBLY TO SECURE CONNECTIONS SHALL BE FOLLOWED. 23 THE ANTENNA CABLES SHALL BE GROUNDED AT THE TOP AND BOTTOM OF THE VERTICAL RUN FOR LIGHTING PROTECTION. THE ANTENNA CABLE SHIELD SHALL BE BONDED TO A COPPER GROUND BUSS AT THE LOWER MOST POINT OF A VERTICAL RUN JUST BEFORE IT BEGINS TO BEND TOWARD THE HORIZONTAL PLANE. WIRE RUNS TO GROUND SHALL BE KEPT AS STRAIGHT AND SHORT AS POSSIBLE. ANTENNA CABLE SHIELD SHALL BE GROUNDED JUST BEFORE ENTERING THE CELL CABINET. ANY ANTENNA CABLES OVER 200 FEET IN LENGTH SHALL ALSO BE EQUIPPED WITH ADDITIONAL GROUNDING AT MID-POINT. 24 ALL GROUNDING CONDUCTORS INSIDE THE BUILDING SHALL BE RUN IN CONDUIT RACEWAY SYSTEM, AND SHALL BE INSTALLED AS STRAIGHT AS PRACTICAL WITH MINOR BENDS TO AVOID OBSTRUCTIONS. THE BENDING RADIUS OF ANY #2 GROUNDING CONDUCTOR IS 8". PVC RACEWAY MAY BE FLEXIBLE OR RIGID PER THE FIELD CONDITIONS. GROUNDING CONDUCTORS SHALL NOT MAKE CONTACT WITH ANY METALLIC CONDUITS, SURFACES OR EQUIPMENT. 25 PROVIDE PVC SLEEVES WHERE GROUNDING CONDUCTORS PASS THROUGH THE BUILDING WALLS AND /OR CEILINGS. 26. INSTALL GROUND BUSHINGS ON ALL METALLIC CONDUITS AND BOND TO THE EQUIPMENT GROUND BUSS IN THE PANEL BOARD. 27 GROUND ANTENNA BASES, FRAMES, CABLE RACKS ANO OTHER METALLIC COMPONENTS WITH #2 GROUNDING CONDUCTORS AND CONNECT TO INSULATED SURFACE MOUNTED GROUND BARS. CONNECTION DETAILS SHALL FOLLOW MANUFACTURER'S SPECIFICATIONS FOR GROUNDING. 28. ALL PROPOSED GROUNDING CONDUCTORS SHALL BE ROUTED AND CONNECTED TO THE MAIN GROUND BAR OR EXISTING GROUND RING. NOTES 1 1 2 . . ------, o : I r-• • I • I I ~· I I I I I I I I I I --~ 2 (N) I I I I I I I I • L-o ~ ... . . I ,-• I I • I I I I I I I I I I I I I I I,. --! I I I I I L--- (E) (E) (E) (E) . EQUIPMENT GROUNDING PLAN SCALE N.T.S. KEY NOTES: 0 (E) EQUIPMENT GROUND BAR TO BE VERIFIED @ FIELD 0 (N) AWG 2 INSULATED COPPER GROUND WIRE NOTES: 1. REFER TO TYP. ANTENNA GROUNDING DIAGRAM 2. (E) GROUND WIRES ARE NOT SHOWN FOR CLARl1Y 24 "x36" SCALE: 3/8" = 1 '-o" 11"x17" SCALE: 3/16" = 1 '-0" 1 2 COAX CABLES ANTENNA GROUND KIT AWG 6 (1YP) AWG 2 (TYP)--~ SECTOR ANTENNA GROUND BAR AWG 2 BCW TO GROUND RING NOTES: 1. GROUND BAR LOCATION IS SCHEMATIC AS SHOWN ON THIS SHEET AND ACTUAL LOCATION OF INSTALLATION WILL BE DETERMINED BY THE INSTALLER. 2. REFER TO ANTENNA PLAN FOR EXACT NUMBER OF ANTENNA, RRU AND DC SURGE SUPPRESSOR <>----JUMP ER RRU RRU DC-SURGE C>------AWG 2 L_ _ _._ __ .1---ANTENNA GROUND BAR @ TOP & BOTTOM OF POLE ~-~ AWG 2 BCW TO GROUND RING TYP. ANTENNA GROUNDING DIAGRAM KEY NOTES: 0 (E) ANTENNA GROUND BAR TO BE VERIFIED @ FIELD 0 (N) AWG 2 INSULATED COPPER GROUND WIRE FROM (N) RRUS TO (E) ANTENNA GROUND BAR Q) (N) AWG 6 INSULATED COPPER GROUND WIRE FROM GROUND KIT TO (E) ANTENNA GROUND BAR NOTES: 1. REFER TO TYP. ANTENNA GROUNDING DIAGRAM 2. (E) GROUND WIRES ARE NOT SHOWN FOR CLARITY 3 3 1 (N) I I I I I I I I I 00 . 0 00 •• ' I I I (E) \ \ I \ I \ I \ I □ □ □ ANTENNA GROUNDING PLAN, TYP. PER SECTOR 3 (N) 2 I 3 (E) N(E) BUILDING ROOFTOPN □ D [J [J ll 24"x36" SCALE: 3/8" = 1 '-0" 11"x17" SCALE: 3/16" = 1'-o" N) 1 2 T 11 ·Mobile 11 T~MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO T-M081LE IS STRICTLY PROHIBITED 0 B A REV 2030 MAIN STREET, SUITE 200 IRVINE, CA 92614 Sil'E NUMBER: SD06088A SITE NAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 12/17/20 100% CONSTRUCTION 11/27 /20 100% CONSTRUCTION 11/16/20 90% CONSTRUCTION DATE DESCRIPTION RD RO AS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET TITLE GROUNDING PLAN & NOTES SHEET NUMBER G1 NOT USED 1 NOT USED NEW GPS ANTENNA~- CABLE TO PIPE CONNECT BURNDY TYPE - = GAR, TYP. ( 2) P LAC E3'----___.j-;- -,- I MOUNTING BRACKET 1 /2"¢ COAX CABLE " \ #2 AWG BCW, TYP. (2) PLACES #6 AWG GROUNDING KIT CABLE BCW TO BCW TO NOT USED 4 GPS ANTENNA GROUNDING TYP. SCALE N.1.S. TYPE ND UNIVERSAL PIPE CLAMP 75/1.25 UNIVERSAL PIPE CLAMP 50H2 TYPE NX1 TYPE SS X TYPE XA TYPE LJ TYPE RR TYPE NC TYPE TA TYPE VB ~ ~ cv ~ TYPE GT TYPE GL LUG ~ ~ TYPE HA TYPE VS TYPICAL MECHANICAL CONNECTIONS TYPE PG $, \\\11 I.Iii lll.ll ~ TYPE PH ~ TYPE GR ~ TYPE PC BOLT GROUND ROD CLAMP 2 HOI E LUG ~"~~ ~1t/ e,_,,---- "U" BOLT PIPE CLAMP 2 BOLT CROSS RUN PARALLEL CLAMP SPLICER ~ ~ CAST "T" 1 BOLT SPLICER PARALLEL SPLICER ~~ (~J) 0 ~ - 1 BOI T PARALLEL CLAMP SCALE N.T.S. 2 NOTES: 1. DO NOT INSTALL CAi3LE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR 2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MFR 3. WEATHER PROOFING SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY THE CABLE MFR 10 0 I IO O I) I I ,. I . ~-STRIP OUTER JACKET AWAY USING APPROVED TOOLS ~~-OUTER JACKET OF COAXIAL CABLE ~-SHIELD ©) ©) I \_ GROUND KIT CLAMP PER MFR SPECIFICATIONS -------#6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR PER NOTES 1 AND 2) I\ It~=¥~~~~1~t _l::.='----'-'\I ri ~ WEATHERPROOFING PER MFR SEE NOTE 3 #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR PER NOTES I AND 2) COAX JUMPER, TYP. CONNECTOR WEATHERPROOFING KIT, TYP. SEE NOTE 2 , TO ANTENNA ' cl-RXI :0 ~ r:1 l;-,J r-r-,~ ' ,- r~1 hi.- , IOI i bi WEATHERPROOFING KIT, TYP. ANDREW SUREGROUND TYPE KIT, TYP ., SEE NOTE ~6 AWG ANTENNA CABLE TO BTS EQUIPMENT, TYP.- ~ rTI ~t!iA~ ~,-rANTENNA GROUND BAR, SIMILAR '\ \ TO DETAIL #4 WITHOUT i o I INSULATORS. BONDED DIRECTLY 0 0 0 0 i ii O O O TO TOP OF POLE OR TOWER 0 0 oooooooof1:I j ' NOTE: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO ANTENNA GROUND BAR. 2. WEATHER PROOFING SHALL BE ANDREW TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED GROUNDING KIT SCALE N.T.S. LEGEND 1-COPPER GROUND BAR, "X 1 / 4"X 20", NEWTON INSTRUMENT CO. CAT. NO. B-6142 DR EQUAL. HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. (ACTUAL GROUND BAR SIZE WILL VARY BASED ON NUMBER OF GROUND CONNECTIONS) 2-INSULATORS, NEWTON INSTRUMENT CAT. NO. 3061-4 OR EQUAL 3-5/8" LOCKWASHERS, NEWTON INSTRUMENT CO. CAT. NO. 3015-8 OR EQUAL 4-WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. CAT NO. A-6056 OR EQUAL 5-5/8-11 X 1" HHCS BOLTS, NEWTON INSTRUMENT CO. CAT NO. 3012-1 OR EQUAL 6-INSULATORS SHALL BE ELIMINATED WHEN BONDING DIRECTLY TO TOWER/MONOPOLE STRUCTURE. CONNECTION TO TOWER/MONOPOLE STRUCTURE SHALL BE PER MANUFACTURERS RECOMMENDATIONS. I NOTE: ALL HARDWARE SHALL BE STAINLESS STEEL I 3 5 GROUNDING KIT SCALE N.T.S. 6 GROUND BAR DETAIL SCALE 7 N.T.S. 8 12" TO 24" 2 11/'16" ¢ MAX. ANTENNA CABLE~ ~ I I WEATHERPROOFING KIT (SEE NOTE 3) CABLE GROUNDING KIT #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) (SEE NOTE 1 & 2) NOTE: I DO NOT INSTALL CABLE GROUND KIT AT A BEND ANO ALWAYS DIRECT WIRE DOWN TO GROUND BAR 2 GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER. 3. WEATHER PROOFING SHALL BE (TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE MANUFACTURER) GROUND KIT CONN TO ANT CABL SCALE N.T.S. 9 #2 AWG FROM EQUIPMENT TO BE --~ GROUNDED ~ ' ~----~, GROUND BA~1-.---,~ \ ~ 0 -~ -~ I I ~ ----- ©©~ Ll © © ©©,©© © © '-' "7'= '-' - ~---j ~'t-s,----------1 -DUAL CADWELDS, TO BE /~ SEO WITH # 2 AWG BC'vv.,_,,__,, TO GROUND RING - 1 ' OVC SEAL TITE NOTE: 1. CONTRACTOR TO UTILIZE KOPR-SHIELD (THANS & BETTS) ON ALL LUG CONNECTIONS DR APPROVED EQUAL 2. ALL LUGS TO BE DUAL HOLE LONG BARREL AND CRIMPED TWICE WITH MFR'S RECOMMENDED TOOL GROUND BAR CONNECTION SILICON SEAL AT TOP SCALE 1 Q 1----.......... --f N.T.S. T · ·Mobile· T-MOBILE WEST LLC THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY & CONFIDENTIAL TO T-MOBILE ANY USE OR DISCLOSURE OTHER THAN K, IT RELATES TO T-MOBILE IS STRICTLY PROHIBITED 0 B A REV 2030 MAIN STREET, SUITE 200 IRVINE, CA 92614 Sfl'E NUMBER: SD06088A SITENAME: LASFLORES 1088 LAGUNA DRIVE CARLSBAD, CA 92008 12/17/20 100% CONSTRUCTION 11/27 /20 100% CONSTRUCTION 11/16/20 90% CONSTRUCTION DATE DESCRIPTION RD RD PS IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET TITLE GROUNDING DETAILS SHEET NUMBER G2