Loading...
HomeMy WebLinkAbout5927 LANDAU CT; ; FPC2020-0204; PermitPERMIT REPORT Fire Permit Print Date: 11/03/2021 Job Address: 5927 LANDAU CT, CARLSBAD, CA 92008-8803 Permit Type: FIRE-Construction Commercial Work Class: Parcel#: 2120611900 Track#: Valuation: $485,796.95 Lot#: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Project#: Plan#: Construction Type: Orig. Plan Check #: Plan Check#: Description: ATLAS INVESTMENT -SPRINKLER Tl (31 HEADS) Applicant: TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611A S MELROSE DR VISTA, CA 92081-5407 (760) 525-4329 FEE FIRE NFPA 13 or 13R System 7 -100 heads Fire Sprinklers Total Fees: $553.00 Total Payments To Date: $553.00 Fire Department {City of Carlsbad Permit No: FPC2020-0204 Status: Closed -Finaled Applied: 12/03/2020 Issued: 01/07/2021 Finaled Close Out: 11/03/2021 Inspector: Final Inspection: Balance Due: AMOUNT $553.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov .... Bulletin 014 Rev. L Relialll~ Model F1 FR Series Quick Response Standard Spray Model F1 FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F1 FR56 Recessed Sprinkler Types Standard Pendent/F 1 /F2/FP Horizontal Sidewall Model F1 FR56 Concealed Sprinkler Types Standard Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler Types Standard Upright Standard Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Recessed Sprinkler Types Standard Pendent Model F1 FR56LL & F1 FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverh0tung GmbH 5. *NSF Certified to NSF/ANSi Standard 61 Annex G 6. EC Certificate: 0786-CPD-40239 (RA 1414 ), 0786- CPD-40251 (RA 1425), 0786-CPD-40252 (RA 1475) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1 FR56, F1FR56LL, F1 FR42, F1FR42LL, F1 FRXLH & F1 FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1 FR56LL, F1FR42, F1FR42LL, F1 FRXLH & F1 FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR56, F1FR56LL, Upright Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal Sidewall XLH Upright Concealed Pendent XLH Pendent F1FR42, F1FR42LL, F1FRXLH & F1 FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- Conventional Recessed Pendent/F1tf2 Recessed PendenttfP XLH Recessed Pendent F 1 /F2 .....__ ____ -----1 rately controlled amount of special fluid XLH Recessed hermetically sealed inside a precisely Pendent FP manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must· be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. *Pin tie (XLH On~) Deflector Washer Frame 014FG06A Load Screw Bulb Cup Model F1 FR42, F1 FRXLH Upright Technical data: Thread Max. Min. Temperature Models Discharge Coefficient Response Working Working Finish Size Pressure Pressure Rating F1FR56 K 5.6 **F1 FR56LL<1> F1FR42 Quick 1/2" NPT See See **F1 FR42LL<1> K4.2 Response (R1/2) 175 PSI 7 PSI "Temperature "Finish Table" F1FRXLH Ratings" Table. F1FR28 K2.8 <1> Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Deflector Load Screw *Plntle Cup Washer Bulb DZR Brass CDA Alloy 260, CDAAlloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass CDA Alloy 220 or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape CDA Alloy510 2. Model F1 FR56, Upright, Pendent & Conventional Sprinklers Model F1 FR42, F1 FRXLH & F1 FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Orifice Size us Metric Height Organization Sprinkler Identification Number (SIN) Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2" (15mm) (1) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) 1,2,3,4, 6 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 Conventional-Install In Upright or Pendent Position 15mm(1l 1/2" NPT (R1/2) 5.6 80 <1J cULus listed corrosion resistant (Polyester coated) sprinkler. <2J Polyester coated FM approved sprinkler. 57mm <3J Polyester coated LPCB & VdS approved sprinkler RA 1425, RA 1414 & RA 1475. <4J Electroless Nickel PTFE (Teflon®)* Plated -cULus listed Corrosion Resistant Upright Pendent Model F1 FR56LL & F1 FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Orifice Size us Metric Height 3,4,6 Approval Organization Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm) <1J 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 5 7/16" (11mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1, 5 <1J cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark 3. RA 1425(1l(2l<3l(4l RA 1414(1X2H3l(4l RA 1423<1)(4) RA1413(4l RA 1421(1)(4) RA1411(4l RA1475(3l Conventional Sprinkler Identification Number (SIN) Pendent RA1415 RA1410 -Model F1 FR56, F1 FR42, F1 FRXLH & F1 FR28 Quick Response Recessed Pendent Sprinkler<1> lnstallatlon Wrench: Model GFR2 Sprinkler Wrench lnstallatlon Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number Orifice Size us Metric Height (SIN) 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1413 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA1411 <1> Refer to escutcheon data table for approvals & dimensions Model F1 FR56LL & F1 FR42LL Quick Response Recessed Pendent Sprinkler<1> lnstallatlon Wrench: Model GFR2 Sprinkler Wrench lnstallatlon Data: Nominal Thread K Factor Orifice Size us Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 <1> Refer to escutcheon data table for approvals & dimensions 1• X 1/2' R£DUCER r,.........L......111B---1J~ll-------l---4----~ AT W.Xllllltl R£CESS -7/8f22.2mm] AT --R£CESS -1-5/Bf•U.Jmm] ~ Sprinkler Sprinkler Identification Number Height (SIN) 2.25" (57mm) RA1415 2.25" (57mm) RA1410 2 .5/lf" lM [tl&7mm] ---I,,-.+--------,,..~ HOtE IN CEIUNG 2 .5/16" lM [!J8.7mm} -.&.J.-----..J.__ ___ ~-CUP C£1UNG I" X 1/2" REDUCER FACE OF F1TTING ro FACE OF CDUNG DIIIENSION AT IIAX1lllM REr;£SS • l-l/2'[»nm] AT "1NMHtl REr;£SS • I 'f25.4mm] T REr;£SS -9/16'f14.::smmJ AT MAX/MUii RCCCSS -1-1/8128.flmm} AT lrllNIMM RCCESS -1-5/Bf•fl . .Jmm] ~ _j 'MM REr;£SS • 1'[2.5.fmm] :J 1/4"£114. [112.6mm] ModelF1FR56,F1FR56LL,F1FR42, F1FR42LL,F1FRXLH& F1 FR28 F1 or F2 ModelF1FR56,F1FR56LL,F1FR42, F1FR42LL, F1FRXLH& F1FR28 FP Model F1 FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench lnstallatlon Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler Thread Size Identification Orifice us Metric Height Organizations Numbers (SIN) ½" (15mm) ½" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3 RA 1485<2><3> 15mm ½" NPT (R1/2) 5.6 80 2.25" (57mm) 3(1) <1> LPG Approval is for pendent position only. <2> cULus Listed corrosion resistant (Polyester coated) sprinkler. <3> Electroless Nickel PTFE (Teflon®)* Plated -cULus listed Corrosion Resistant Vertical Sidewall *DuPont Registered Trademark 4. Sprinkler Type U ri ht Pendent Deflector to Celling Distance Min. -Max. 4" 102mm -12" 305mm 4" 102mm -12" 305mm Temperature Ratings Sprinkler Max. Ambient Classlflcatlon Temm ~rature Bulb Color oc Of Temp. Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green Hiah (1l 141 286 225°F (107°C) Blue <1l Not available for recessed sprinklers. Escutcheon Data <1> <1> SIN RA 1435 -cULus permits use with F1, F2 or FP escutcheons for "light hazard" only, while FM lim~s use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1 FRXLH and Model F1FR56, F1 FR56LL, F1 FR42, F1 FR42LL, F1 FRXLH & F1 FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) *DuPont Registered Trademark 7. Finishes <1> Standard Finishes Snrlnkler Escutcheon Cover Dlate<1> Bronze Brass Chrome Chrome Plated Chrome White Po Ivester Plated Coated (4l(5l(5l White Painted SDSC lal Annllcatlon Finishes SDrlnkler Escutcheon Cover Dlate<1> Electroless Nickel Electroless Nickel Bright Brass PTFEff eflon®)*(7l PTFE (Teflon®)* Briaht Brass(3l Briaht Brass Black Platina Black Plated Black Plated Black Paint Black Paint(2l(5l Black Paint Off White Off White(2l(5l Off White Satin Chrome Chrome Dull Chrome Dull <1l Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. <2l cULus Listed only. <3> 200°F (93°C) maximum. <4> cULus listed "corrosion resistance" applies to SIN Numbers RA 1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. <5> FM Approvals finish as "Polyester coated" applies to SIN Number RA 1414, RA 1435 and RA 1425 in standard black or white. <5l LPCB and VdS Approved finish applies only to RA 1425, RA 1414 and RA 1475. <7l cULus listed Corrosion Resistant Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) 9. Cover plate Model 10. Cover plate Thread size 11. Cover plate Temperature 12. Cover plate Adjustment 13. Cover plate Finish Note: When Model F1 FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. ' .. Bulletin 110 August 2019 OJ C Reliable ',-CD Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construc- tion. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this happens, the lever is released to spring free from the sprinkler so that all of the operating parts clear from the waterway al- lowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above, the sprinkler components are made from copper based alloys for maximum corrosion protection. Lead plated, wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by mark- ings that appear on several of the operating parts and by an identifying color that appears on the frame. Sprinkler Types Standard Upright-This deflector configuration is normal- ly used with exposed piping installations. Water is distrib- uted laterally and downward in a wide pattern approximat- ing a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. Standard Pendent -This deflector configuration is nor- mally used where the space above the piping is limited or where a concealed piping installation is employed. The discharge characteristics of the standard pendent are virtually identical to the standard upright as de- scribed above. Large and Small Orifice -By varying the orifice size, a large or small orifice sprinkler is created that will distrib- ute as much as 40% more water or 65% less water than the normal½" (15mm) orifice sprinkler. Conventional -This deflector configuration is used pri- marily in those countries where the LPG installation rules have precedence. The sprinkler is designed to distribute a portion of its water discharge upward against the ceil- ing with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, ordinary and extra-high hazard installations. Model G Automatic Sprinklers Spray Upright, Spray Pendent, And Conventional Upright Small Orifice Upright Conventional Application and Installation Standard sprinklers are used in fixed fire protection sys- tems: Wet, Dry, Deluge or Preaction. Care must be exer- cised that the orifice sizes, temperature ratings, deflector styles and sprinkler spacings are in accordance with the latest published standards of the National Fire Protection Association or the approving authority having jurisdiction. The sprinklers must be installed with the Reliable Model W2 Sprinkler Wrench. Any other type of wrench may dam- age the sprinkler. The approvals or listings of Reliable Automatic Sprin- klers by major approving organizations are shown in the tabulated list provided on the back of this bulletin. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 ...... s· .....L .....L 0 )> C (C C se. ~ (0 · Technical Data Sprinkler Type "K" Factor Sprinkler Approvals Sprinkler Identification Number (SIN) • us Metric Height ssu SSP Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position ½" (15 mm) Standard Orifice with½" NPT (R1/2) Thread 5.62 7/16" (11 mm) Small Orifice with 1/2'' NPT (R1/2) Thread 4.24 3/a" ( 10 mm) Small Orifice with 1/2'' NPT (R1/2) Thread 2.82 5/16" (8 mm) Small Orifice with 1/2'' NPT (R1/2) Thread 1.98 17/32" (20 mm) Large Orifice with 1/2'' NPT (R¼) Thread 7.96 17/32'' (20 mm) Large Orifice with 3/4'' NPT (R3/4)Thread 8.20 20 mm XHH with 20 mm Thread 8.20 10 mm XLH with 10 mm Thread 4.10 Conventional-Installed in Upright or Pendent Position 10mm XLH with 10mm Thread 4.10 15mm Standard Orifice with (R1/2) Thread 5.62 20mm XHH with (R3/4) Thread 8.20 -_,.■--. -Maximum Sprinkler Ambient Frame !1l Classification Rating Temperature Color OF oc OF oc Ordinary 135 57 100 38 Black Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White Hiah 286 141 225 107 Blue (ll Frame color does not apply to painted or plated sprinklers -Use sprinkler rating as identified on operating parts. Finishes '1, Standard Finishes Bronze -All Temperature Ratings Chrome -All Temperature Ratings White !2l -All Temperature Ratings Only Frame and Deflector are Painted Special Aoolication Finishes Bright Brass Plated -Only frame, deflector and cap are plated. 135°F (57°C), 165°F (74°C), 212°F (100°C) Temp. Rating. Black Plated -Only frame, deflector and cap are plated. All Polyester Coated !2x4i Temp. Ratings. Lead Plated -Only frame and deflector are coated. Wax-Coated !3l -165°F (74°C), 212°F (100°C) and 286°F (141°C) Wax-Coated Over Temp. Ratings. Lead Plated !3l -165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. -165°F (74°C) Clear Wax, 212°F (100°C) Brown Wax. (ll Other colors and finishes are available. Consult factory for details. !2l UL listed and NYC MEA Approved only. !3l 212°F ( 100°C) brown wax may be used on 286°F ( 141 °C) 81.0 61.0 40.6 28.5 114.7 118.2 118.2 59.1 59.1 81.0 118.2 sprinklers when maximum ambient temperatures do not exceed 150°F (66°C). UL Listed, FM Approved, NYC MEA 258-93-E. !4l FM Approved for R1027 only. 2 7/a" (73 mm) 1,2,3,4,5,6 R1025 R1015 27/a'' (73mm) 1 R1023 R1013 27/a''(73mm) 1, 2, R1021 R1011 2 7/a" (73 mm) 1, 5 R1022 R1012 2 7/a'' (73mm) 1, 2, R1026 R1016 2 15/16" (75 mm) 1, 2, R1027 R1017 75.4mm 3, 4, R1027 R1017 73mm 3, 4, R1024 R1014 73mm 4 R1074 73mm 3,4,6 R1075 75.4 mm 3,4 R1077 Maintenance Model G Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other clean- ing fluids. Remove any sprinkler that has been painted ( other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging un- til used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Use only the Model W2 Sprinkler Wrench for sprinkler removal and installa- tion. Any other type of wrench may damage the sprinkler. Approval Organizations 1. Underwriters Laboratories, Inc. and UL Certified for Can- ada (cULus). 2. Factory Mutual Research Corporation 3. Loss Prevention Council 4. Pleniere Assembles 5. N.Y.C. BS&A No. 587-75-SA or N.Y.C. MEA 258-93-E 6. CE Certificate: 1438-CPD-0054 (R1015) 1438-CPD-0053 (R1025) 1438-CPD-0052 (R1075) 1438-CPD-0056 (R1077) Ordering Information Specify: 1. Model G 2. Deflector • Upright • Pendent • Conventional 3. Nominal Orifice 4. Inlet Thread 5. Temperature Rating 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years. Manufactured by Reliabl~ Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address ,:;,,._ Recycled W Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 08/19 P/N 9999970005