Loading...
HomeMy WebLinkAbout1040 CARLSBAD VILLAGE DR; ; FPC2020-0054; PermitPERMIT REPORT Fire Permit Print Date: 04/14/2022 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: 1040 CARLSBAD VILLAGE DR, CARLSBAD, CA 92008 FIRE-Construction Commercial Work Class: Track#: $0.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Fire Alarm (city of Carlsbad Permit No: FPC2020-0054 Status: Closed -Finaled Applied: 03/26/2020 Issued: 05/12/2020 Finaled Close Out: 06/23/2021 Inspector: Final Inspection: Description: CARLSBAD VILLAGE LOFTS -NEW FIRE ALARM SYSTEM (ADDRESSABLE, 414 DEVICES) FEE FIRE Hourly Services First Hour FIRE Hourly Services First Hour FIRE Hourly Services First Hour FIRE Hourly Services First Hour FIRE New Alarm System Total Fees: $1,901.00 Fire Department Total Payments To Date: $1,901.00 FPContractor: EMCOM ELECTRONIC SYSTEMS INC 256 WITHERSPOON WAY, # STE H EL CAJON, CA 92020-2755 (619) 667-1200 Balance Due: AMOUNT $159.00 $159.00 $159.00 $159.00 $1,265.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadc~.gov EIVICOIVI ELECTRONIC SYSTEMS, INC. GALIC. 820216 SEC. LICACO 3838 256 WITHERSPOON WAY, SUITE H • EL CAJON, CA 92020 • PH. (619) 667-1200 • FAX (619) 667-1222 Fire Alarm System Equipment Submittal For Carlsbad Village Lofts 1040 Carlsbad Village Drive Carlsbad, CA 92008 Permit# PC2019-0052 EMCOM ELECTRONIC SYSTEMS PROJECT NAME: Calrsbad Village Lofts RESPONSE: Construction Changes ifEM ""t6MMENT r'~ ' •'t ~-~ .1•' ~::~ ·.~--~,...~.~ .. ,-'~·1 ~,,; _·1~1,• ;~ .--:.' ,"::,_!._: ~-~\~ij '/[-~,_!·~: 1 Added sounders to dens per insperctors commetns 2 Added smoke fire dampers, modules, smoke and heat detectors Project Revisions w te: 5/17121 : Wlil"'-Mirco1rr INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom's FX-2000 Series Microprocessor Based Intelligent Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements while also providing easy installation and operation at a cost-effective price. The FX-2000 base panel consists of one intelligent analog loop controller capable of supporting 99 Analog Sensors and 99 Addressable Modules which can be wired in Class A (Style 6 or 7) or Class B (Style 4 ). The system can be expanded by adding additional Analog Loop Controller Modules. In addition the base panel supports 16 conventional hardwire adder modules such as the DM-1008A Initiating Circuit Module, SGM- 1004A Indicating Circuit Module and the RM-1008A Relay Circuit Module. Additional conventional hardwire adder modules can be added with the ALC-H 16 Adder Hardwire Loop Controller Module, which allows the system to support an additional 16 conventional adder modules. The base panel also consists of 4 Class A/B (Style Z/Y) Indicating Circuits rated at 1. 7 Amps each and either a 6 or 12 Amp Power Supply. Equipped with a large 4 x 20 Back-lit Alphanumeric LCD display, the FX-2000 utilizes a simple_ Menu system complete with a directional keypad, common control switches and LEDs, Alarm Queue switches and LEDs and two configurable input switches. Features Listed to UL 864, 9th edition Large system capacity Modular design Each Analog Loop is capable of supporting 99 Analog Sensors and 99 Addressable Modules which can be wired in Class A (Style 6 or 7) or Class B (Style 4) Base system supports 16 conventional hardwired modules with the provision to add more using the ALC-H 16 Hardwire Loop Controller Module 6 or 12 Amp power supply · Four Class A/B (Style ZN) Indicating Circuits rated at 1. 7 Amps each Configurable for Two Stage operation Three level password protection with field programmable definition which enables the installer to determine what functions are accessible for each password level Panel Security to protect site configurations Manual Control Enable which allows password protection for all front panel function switches Correlatable Switch Inputs which allows for multi- functional outputs Four Alarm Queues with selector switches and LEDs for Alarm, Supervisory, Monitor and Trouble Auxiliary relay contacts for Common Alarm, Common Supervisory and Common Trouble RS-232 output for remote system printer or CRT Two Event History Logs comprised of a 1000 Alarm History Log for alarm related events and a 2000 Event Log for all events Front Panel Auto-Configure and/or Computer laptop Programmable Large 4 by 20 character Back-lit LCD Display with user friendly menu Common Control switches and/or indicating LEDs for System Reset, Signal Silence, Fire Drill, Acknowledge, General Alarm, Lamp Test, AC. On, Pre-Alarm and Ground Fault Built-in One Man Walk Test operation Configurable for Coded Operation Supports an RS-485 interface to the QX-5000 Voice Evacuation System Panel selection for Canadian (ULC) or U.S.A. (UL) requirements for smoke sensors (sensitivity) via computer laptop Capability to adjust Intelligent Smoke Detector sensitivity level <S> ® @c a 3-;3~;0 c?~:a~~ ~ <S'~;·:;~·-c."' M EA Class I (Con) E15095 Class II (Con) E15096 S7010 S7010 7165-1477 111 approved 81:~~ l1(~d~) ~~~8§~ 7170-1477:119 313-97-E H1ghnse CATALOG NUMBER 591 ( NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours. materials, components, equipment, specifications and models and also to discontinue models. Operation The FX-2000 is field programmable via the front panel auto configuration or a laptop computer. In addition, it allows for a three level passwor~ protection that can be field defined via a laptop computer. This unique feature allows the installer to determine what functions are accessible for each password level. The system is also equipped with two Event History Logs; one for Alarm and the other for full panel sequence events. The Alarm History Log (1000 events) contains all alarm related functions while the Event Log (2000 events) provides a full sequence log of all operations, as well as alarms and troubles. Both Event History Logs can be used during the One Man Walk Test operation. This allows the event logs to be downloaded to a laptop or printer for a permanent record. The FX-2000 is a very flexible system which supports both internal and external annunciation modules. The internal annunciation modules consist of the RAX-1048TZDS Programmable Zone LED Annunciator, the IPS-2424DS Programmable Input Switches Module, the FDX-008 Fan Damper Module and the AGD-048 Adder Graphic Driver Module. Input Correlations All input circuits (addressable or hardwired) can be configured for non-verified alarm, verified alarm, waterflow, latching/non-latching supervisory, monitor, trouble only or remote switch inputs. All of the input configuration types listed above, with the exception of remote switch can be programmed to operate relays, signal and strobe circuits for hardwired or addressable devices. Please refer to the chart below for correlations. The input circuits configured as non- latching will cause the output circuits configured to them to follow the state of the input device. This feature allows for the connection of multiple panels together for signal operation. Intelligent or Conventional Input Types Relay Non-Verified Alarm Yes Verified Yes Waterflow Yes Non-Latching Supervisory Yes Latching Supervisory Yes Monitor Yes Trouble Only Yes Remote Switch Input No All of these modules mount within the panel and are driven from the main LCD display. The external annunciator modules include the RAM-1032TZDS and RAX-1048TZDS LED Remote Annunciators, the MGD-32 Master Graphic Driver Module, and the RAX-LCD Remote LCD Shared Display. The RAX-LCD Remote LCD Shared Display provides the same features as the main display on the FX-2000. In addition the RAX-LCD also acts as a driver module that allows for the RAX-1048TZDS, IPS-2424DS, FDX-008 and AGD-048 to be connected to it. The RAX-LCD is required as a driver module any time any of the above mentioned external annunciator modules are programmed differently from those on the main panel or are mounted remote from the main panel. In addition to these adder modules, the FX-2000 also supports the UDACT-300A Digital Communicator Module and the PR-300 Polarity Reversal/City Tie Module. The FX-2000 also supports an RS-485 interface to the QX-5000 Emergency Zoned Audio System. The Remote Switch input, which must be momentary, allows any input type device (addressable or hardwired) to be configured as a common control functions such as fire drill, system reset, signal silence etc. The remote switches operate in a momentary mode like the control switches on the FX- 2000 main panel. For functions such as fire drill, the remote switch functions in a toggle mode, with one press for "on" and one press for "off'. The remote switch is supervised for "stuck in on" positions, where the switch input is activated (stuck) for more than 30 seconds. If this occurs, a trouble is generated and clears when the input goes away. Output Control Switches Signal Strobe Yes Yes No Yes Yes No Yes Yes No Yes Yes No Yes Yes No Yes Yes No Yes Yes No No No Yes lillilk Mircom'" NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 2 of 10 FX-2000 Standard Series FX-2003-6D5/FX-2003-12D5 Compact Main Control Units The FX-2003-6DS and FX-2003-12DS Compact Main Control Units come complete with one Intelligent Signaling Line Circuit, Four Style ZN (Class A/B) Notification Appliance Circuits rated at 1.7 Amps each and a 4 line by 20 character back-lit LCD display. The FX-2003-6DS is equipped with a 6 Amp Power Supply which charges 10-24 AH batteries while the FX-2003-12DS includes a 12 Amp Power Supply which charges 17-55 AH batteries. The FX-2003-6DS/FX-2003-12DS provides space for 3 adder modules and 2 internal annunciator adder modules. The FX-2003-6DS/FX-2003-12DS mount in a UB-1024DS backbox. FX-2003-6DS-16LED Compact Main Control Unit The FX-2003-6DS-16LED Compact Main Control Unit come complete with one Intelligent Signaling Line Circuit, Four Style Z.JY (Class A/B) Notification Appliance Circuits rated at 1.7 Amps each and a 4 line by 20 character back-lit LCD display with 16 LEDS for annunciation (DSPL-420-16TZDS). This display is functionally equivalent to the classic FX-2000 main display, but more compact adding in the 16 LEDs for annunciation in addition to all the standard functions. The FX-2003-6DS-16LED is equipped with a 6 Amp Power Supply which charges 10-24 AH batteries. The FX-2003-6DS-16LED provides space for 3 adder modules and 2 internal annunciator adder modules. The FX-2003-6DS-16LED mounts in a separate ordered UB-1024DS Backbox FX-2017-12ADS Mid-Size Main Control Unit The FX-2017-12ADS Mid-Size Main Control Unit comes complete with one intelligent Signaling Line Cirruit ( SLC) Four Style ZN ( ClassA/B) NAC Circuits (1.7 Amps each), a 4 line by 20 character back~it LCD display and a 12 Amp Power Supply which charges 17-55 AH batteries . The FX-2017-12ADS has space for up to 17 adder modules and 3 internal annunciator adder modules. The FX-2017-12ADS mounts in the BBX-1072ADS enclosure. FX-2009-12DS Large Size Main Control Unit The FX-2009-12DS Large Size Main Control Unit comes complete with one Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 Class A/B (Style Z!Y) Indicating Circuits (1.7 Amps each), a 4 line by 20 character back-lit LCD display and a 12 Amp Power Supply which charges 17-55 AH batteries. The FX-2009-12DS supports 16 conventional adder modules and provides space for up to 9 adder modules and 3 internal annunciator adder modules. The FX-2009-12DS mounts in the BB-5000 Series enclosures. ECX-0012 Expander Chassis The ECX-0012 Expander Chassis for the FX-2009-12DS/FX-2009S-12 supports up to 12 adder modules and has space for 2 internal annunciator modules. The ECX-0012 mounts in the BB-5000 series enclosures. FX-2000 Standard Series System Maximums • 495 Input Circuits • 150 Output Circuits • 5 Intelligent Addressable Loops • 4 Remote LCD Annunciators • 4 Main LED Annunciators • 100 Manual Control Switches • Ir om ,·,., NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 3 of 10 Adder Loop Controller Modules ALC-198S Single Analog Loop Controller Module The ALC-198S Single Analog Loop Controller Module provides an additional analog loop to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules. The ALC-198S occupies one module slot in the FX-2000 main or expander chassis. ALC-396S Dual Analog Loop Controller Module The ALC-396S Dual Analog Loop Controller Module provides two additional analog loops to the FX-2000 consisting of 99 Analog Sensors and 99 Addressable Modules per loop. The ALC-396S occupies one module slot in the FX-2000 main or expander chassis. ALC-H16 Hardwire Loop Controller Module TheALC-H16 Hardwire Loop Controller Module allows the FX-2000 to support an additional sixteen ( 16) conventional hardwire adder modules. The hardwire modules consist of the DM-1008 Eight Initiating Circuit Module, SGM- 1004 Four Indicating Circuit Module and the RM-1008 Eight Relay Circuit Module. TheALC-H16 occupies one module slot in the FX-2000 main or expander chassis. Adder Auxiliary Modules UDACT-300A Digital Alarm Communicator Module The UDACT-300A Digital Alarm Communicator Module allows the FX-2000 to transmit addressable point information to a central station. The UDACT-300A can be configured locally via the on-board keypad and the CFG-300 Configuration Tool or with a UIMA programming tool and a computer with an available serial or USS port. The UDACT- 300A occupies one module slot in the FX-2000 main or expander chassis. Adder Hardwire Modules DM-1008A Eight Initiating Circuit Module The DM-1008A provides 8 Class 8 (Style 8) or 4 Class A (Style D) Initiating Circuits configurable for Alarm, Supervisory or Trouble zones. The DM-1008A occupies one module slot in the FX-2000 main or expander chassis. SGM-1004A Four Indicating Circuit Module The SGM-1004A provides 4 Class A/8 (Style Z/Y) Indicating Circuits configurable as Silenceable or Non-Silenceable. Each Indicating Circuits is rated at 1. 7 Amps. Each of the indicating circuits have individual signal silence inputs which are jumper selectable. The SGM-1004A occupies one module slot in the FX-2000 main or expander chassis. RM-1008A Eight Relay Circuit Module The RM-1008A provides the FX-2000 with 8 individual configurable relays per module. Each relay provides one Form C contact rated at 28 VDC @1 Amp (resistive load). The RM-1008A occupies one module slot in the FX-2000 main or expander chassis. PR-300 Polarity Reversal/City Tie Module The PR-300 Polarity Reversal/City Tie Module provides the system with a supervised City Tie (24 VDC/200 mA max.) and Polarity Reversal connection (24 VDC ( open circuit), 8 mA max. (shorted)). The PR-300 mounts in the FX-2000 main chassis. • ire m NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 4 of 10 Programmable Modules RAX-1048TZDS Programmable Zone LED Annunciator Module The RAX-1048TZDS Programmable Zone LED Annunciator Module provides 48 programmable bi- coloured LEDs. The RAX-1048TZDS connects to the main panel or the RAX-LCD Shared Display when mounted remotely. The RAX-1048TZDS occupies one display position in the BB-1000 or BB-5000 enclosures. FDX-008 Fan Damper Module The FDX-008 Fan Damper Module provides individually programmed circuits which can be used for fan or damper control. Each circuit has a slide-in label, a three position selector switch, green "run or open" LED and an amber "off or closed" LED. The three-position selector switch has a centre "auto" position, a left "off or close" position and a right "on or open" position. The FOX- 008 connects to the main panel or the RAX-LCD when mounted remotely. It uses MIX-MS00CH for control of fans or dampers and two MIX-M501 A for status. The FDX-008 occupies one display position in the BB-1000 or BB-5000 enclosures. IPS-2424DS Programmable Input Switches Module The IPS-2424OS Programmable Input Switches Module provides 24 programmable switches that can be configured for ancillary functions such as zone bypass or added common control functions. The switches operate in a toggle operation with one press for "on" and one press for "off''. The IPS-2424OS connects to main panel or the RAX-LCD when mounted remotely. The I PS-2424OS occupies one display position in the BB-1000 or BB-5000 enclosures. Electrical Ratings Current Consumption FX-2003-6DS-16LED 230 mA 380 mA FX-2003-6DS FX-2003-12OS 230 mA 380mA FX-2017-12ADS 230 mA 380mA FX-2009-12OS 230 mA 380mA ALC-198S/ALC-396S 35mA 50mA ALC-H16 35mA 50mA DM-1008A 80mA 100 mA SGM-1004A 35mA 150 mA RM-1008A 25mA 150 mA PR-300 50mA 300 mA UDACT-300A 40mA 60mA RAX-LCD 100 mA 150 mA IPS-2424OS 10mA 144 mA FDX-008 10mA 100 mA MGD-32 35 mA 1.6Amps AGD-048 25mA 2.4Amps RAM-1032TZDS 50mA 150 mA RAX-1048TZDS 15 mA 100 mA NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 5 of 10 Remote A nnunciators RAX-LCD Remote Shared Display The RAX-LCD Remote Shared Display is a remote annunciator that provides the same functions as the main display on the fire alarm control panel, less the 16 zone LEDs. In addition to operating as a remote annunciator, it can also be used as a driver module for standard LED annunciation or reduced zone annunciation (different from the main panel annunciation), graphic drivers programmed different from the main annunciators, programmable switch modules with a unique configuration and fan damper control also with a unique configuration. Each time a different type of annunciation configuration is needed an additional RAX-LCD is required. The RAX-LCD occupies one display position in the BB-1000 or BB-5000 enclosures. RAM-1032TZDS Main Remote LED Annunciator The RAM-1032TZDS Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. Each display point can be identified by the slide-in label that slides in beside the LED. The RAM-1032TZDS is equipped with sealed membrane- like buttons for Common Control functions. The RAM- 1032TZDS allows for the control switches to be disabled on a per function basis for areas that do not require certain common control functions to be remotely located from the fire alarm control panel. The RAM-1032TZDS can be programmed differently than the main panel annunciator or a remote RAX-LCD. All RAM-1032TZDS remote annunciators on the system must be programmed the same. The RAM-1032TZDS occupies one display position in the BB-1000 or BB-5000 enclosures. RAX-1048TZDS Adder Remote LED Annunciator The RAX-1048TZDS Adder Remote LED Annunciator provides an additional 48 points of LED annunciation. The RAX-1048TZDS is an expandible module that connects to the RAM-1032TZDS. The RAX-1048TZDS occupies one display position in the BB-1000 or BB-5000 enclosures. Graphic Annunciator Driver Modules MGD-32 Master Graphic Driver Module The MGD-32 Master Graphic Driver Module provides common control inputs for the common control switches such as System Reset, Signal Silence, Auxiliary Disconnect, Fire Drill, Lamp Test, Acknowledge and General Alarm. Any or all of these switch inputs can be used. There are supervised outputs for all of the support LEDs and the common control switches. The MGD-32 can also drive up to 32 supervised outputs. These output points are capable of driving LEDs or incandescent lamps. Mounts in a graphic annunciator wallbox or in the BB-5000 enclosures. External power supply required for incandescent lamps and lamp test. AGD-048 Adder Graphic Driver Module The AGD-048 Adder Graphic Driver Module can be used with the MGD-32 Master Graphic Driver modules, or if located remotely it must be connected and mounted with the RAX-LCD Shared Display. The AGD-048 will support an additional 48 supervised outputs. As with the master modules, the AGD-048 will support both LEDs and incandescent lamps. Mounts in a graphic annunciator wallbox or in the BB-5000 enclosures. NOTE: The combined total of RAM-1032TZDS and MGD-32 per system is eight. All RA-1000 Series annunciators or Graphic driver modules must have the zoned LED or graphic LED correlated to the same combination of addressable devices or hardwired zones . However, the zoned LED annunciator on the FX-2000 main panel can be programmed differently from the annunciators mounted remotely. NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 6 of 10 Enclosures OOX-10240S OOX-10240SR UB-1024D5 Universal Backbox The UB-1024OS Universal Backbox houses the FX-2003- 60S or FX-2003-120S main control unit and provides space to mount up to 17 AH batteries. A DOX-1024OS(R) door is ordered separately. Dimensions (minus built-in trim ring): 26"H x 14.5"Wx 4.2"0 DOX-1024OS(R) Door The DOX-1024OS mounts on the UB-1024OS backbox. The door features the universal CAT-30 lock and is available in a white (DOX-1024OS) or red exterior (DOX-1024DSR). 88-5008 The BB-5008 is a lobby control centre enclosure which is capable of handling one FX-2009-12OS Large Main Control Unit which supports 2 internal annuciator modules such as the IPS-2424OS, FDX-008, RAX-1048TZDS, etc. In addition the BB-5008 allows for 4 footprints for mounting Audio Lobby Control modules, Fire Fighter's Lobby Control modules and FX-2000 lnternaIAnnunciatormodul$s. The cabinet hold up to 24 AH batteries. Door and Chassis hardware are ordered seperately. Dimensions: 36"H x 30'W x 7"D Other Enclosures 88-1001 : 9"H X 12. 75"W X 1.2"0 88-1002: 18"H x 12.75"Wx 1.2"0 88-1003: 26.4"H x 12.75"Wx 1.2"0 88-1008: 33"H x 22.5"W x 1.25"0 88-1012: 45"H x 22.5"W x 1.25"0 BBX-1072ADS The BBX-1072ADS enclosure is capable of handling one FX-2017-12ADS Mid-Size Main Control Unit as well as up to 24 AH Batteries. The cabinet features the universal CAT-30 lock and a removable door for easy installation and servicing. The cabinet is available in a white or red exterior (BBX-1072ARDS). Dimensions (minus built-in trim ring): 32.5"H x 25'W x 6 .5"D BB-5014 The BB-5014 is a lobby control centre enclosure which is capable of handling one FX-2009-12OS Large Main Control Unit which supports 2 internal annuciator modules such as the IPS-2424OS, FDX-008, RAX-1048TZDS, etc. In addition the 88-5014 allows for 10 footprints for mounting Audio Lobby Control modules, Fire Fighter's Lobby Control modules and FX-2000 Internal Annunciator modules. The BB-5014 can also support a graphic annunciator in place of these modules. The cabinet holds up to 24 AH batteries. Door and Chassis hardware are ordered seperately. Dimensions: 60"H x 30"W x 7"D /);/);"' Mircom,, NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 7 of 10 Typical FX-2000 Panel Wiring Class B (Style 4) r -~~------.----- L Graphic Annunciator W11llbox c/w graphic annunciator, MGD-32 M<1stcr Graphic Driver module and AGD-048 Adder Graphic Driver modules Conventional Heat Sensors and Manual Pull Stations f-----r--I -1-4th Floor --------------------- I I Signal---+ Circuits 3&4 24 VDC Riser Non------11--+--:::::::r:::::> Resettable Power 24 voe Riser Resettable Power Conventional Hardwired Indicating -+--1<::I::::>I Circuit #2 Data Loop #1 Graphic Annunciator c/w AGD-048 modules ~ Cl ~ 11r;.1❖§1 --- 1 t- i r I --- ~ ~- BB-5008 enclosure c/w RAX-LCD, RAX-1048TZDS, IPS-2424DS and FDX-008. 3rd Floor ------------- BB-1003 enclosure c/w RAX-LCD, RAX-1048TZDS and IPS-2424DS 2nd Floor ---------------------- 1 Pair for RS-485 1 Pair for 24 Voe FX-2009-12OS Large Main Chassis in a BB-5014 enclosure c/w ECX-0012 Expander Chassis, RAX-1048TZDS, IPS-2424OS, FDX-008 and AGD-048. Includes DM-1008A Conventional Indicating Circuit Modules. External power supply is required for incandescent lamps and lamp test. LE /Jilk, Mi rcom '" NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 8 of 10 Ordering Information FX,-200QS~~~~ff§erie§ FX-2003-6DS-16LED Compact Main Control Unit c/w one Intelligent Signaling Line Circuit, Four Style Z/Y (Class A/8) Notification Appliance Circuits rated at 1. 7 Amps each and a 4 line by 20 character back-lit LCD display with 16 LEDS for annunciation (DSPL-420-16TZDS). This display is functionally equivalent to the classic FX-2000 main display, but more compact adding in the 16 LEDs for annunciation in addition to all the standard functions. TheFX-2003-6DS-16LED is equipped with a 6 Amp Power Supply which charges 10-24 AH batteries. The FX-2003-6DS-16LED provides space for 3 adder modules and 2 internal annunciator adder modules. Order UB-1024DS and DOX-1024DS(R) s~parat~ly. FX-2003-6DS Compact Main Control Unit c/w one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class A/8 (Style Z/Y) Indicating Circuits (1.7 Amps each), a 6 Amp power supply and a backbox. Supports up to 16 Conventional Adder Mod- ules. Provides space for 3Adder Modules and 2 internal annunciation modules. Order UB-1024DS and DOX-1024DS(R) separately. FX-2003-12DS Compact Main Control Unit c/w one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class A/8 (Style Z/Y) Indicating Circuits (1.7 Amps each), a 12 Amp power supply and a backbox. Supports up to 16 Conventional Adder Mod- ules. Provides space for 3 Adder Modules and 2 internal annunciation modules. Order UB-1024DS and DOX-1024DS(R) separately. FX-2017-12ADS Mid-Size Main Control Unit c/w one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class A/8 (Style Z/Y) Indicating Circuits (1.7 Amps each) and a 12 Amp power supply. Supports up to 16 Conventional Adder Modules. Provides space for 17 Adder Modules and 3 Internal Annunciation modules. Mounts in the BBX- 1072ADS enclosure. FX-2009-12DS Large Main Control Unit c/w one Intelligent Analog Loop Controller (99 Analog Sensors and 99 Addressable Modules), 4 x 20 Back-lit LCD display, 4 Class A/8 (Style Z/Y) Indicating Circuits (1.7 Amps each) and a 12 Amp power supply. Supports up to 16 Conventional Adder Modules. Pro- vides space for 9 Adder Modules and 3 Internal Annunciation modules. Mounts in the 88-5000 series enclosures. ECX-0012 Expander Chassis for the FX-2009-12DS c/w space to add up to 12 adder modules and 2 Internal Annunciation modules. Mounts in the 88-5000 series enclosures Ad~er Loop ~ontroller IVlodute$ ALC-198S Singl~ Loop lntelligentAnalog Loop Controller Module (99Analog Sensors and 99Addressable ModLJles) ALC-396S Dual Loop Intelligent Analog Loop Controller Module (198 Analog Sensors and 198 Addressable Modules) ALC-H 16 :··::.r:t'''>::·:••r':,:,r::>.:' Controller Module. Supports 16 Conventional Hardwired Modules Adder Har~wire MOJCJUles DM-1008A Eig~t Class 8 (~tyle B) ()_r 4 Class A (Style C>) Initiating ~i~cuit Module SGM-1004A Four Class A/8 (Style Z/Y) Indicating Circuit Module (Rated at 1.7 Amps per circuit) RM-1008A Eight Relay Circuit Module c/w eight form C relays (Rated for 28 VDC @ 1 Amp max. per relay) .. Adder Auxi!iary Modµle~ · UDACT-300A Digital Alarm Communicator Transmitter/Dialer Module PR-300 Polarity Reversal and City Tie Module P:rogramm~ble Modules . · RAX-1048TZDS Programmable Zone LED Annunciator Module c/w 48 bi-c()loure~ IPS-2424DS Pre>grammable lnpLJt Switches Module c/w 24 selector switches and 24 bi-colour~d LEDs FDX-008 Fan Damper Control Module c/w 8 programmable switches · ~emote Annuncia.to~, RAM-1032TZDS rv1ain Annun~iclt()_r Cha~sis c/w Comr:r,on Control Features, Indicators and 32 Bi-Coloured LEDs RAX-1048TZDS Adder Annunciator Chassis c/w 48 Bi-Coloured LEDs RTl-1 Remote Trouble Indicator ,:B!mote ~h~re~ OiSJ)~fY ~vn~ri~{~~~ ' : RAX-LCD Remote Shared Display Queues and Common Controls G~phi~ ArJf1U1;1(?iator briv~r ~9,~ijles ,, . MG D-32 Master Graphic Driver Module c/w Fire Alarm Common Control Switch Inputs and 32 Supervised Outputs AGD-048 Adder Graphic Driver Module c/w 48 Supervised Outputs NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5910 page 9 of 10 Ordering Information cont'd ;·t?<': •·:,··::j':/f'.:::, .. _·. Universal backbox for FX-2003~6DS/FX-2003-12DS. Order DOX-1921QS separat~ly \/\/hite door for U B-1024DS backbox Red door for UB-1024DS backbox :enclosures UB-1024DS DOX-1024DS DOX-1024DSR BBX-1072ADS Black backbox enclosure for FX-2000 dw removable door and CAT-30 lock and key. Houses one FX- 2017-12ADS Mid-Size Main Control Unit and up to 24AH batteries. Includes \/\/hite door BBX-1072ARDS BB-5008 DOX-5008M DOX-5008MR CCH-5008 BB-5014 DOX-5014M DOX-5014MR CCH-5014 Black backbox enclosure for FX-2000 dw removable door and CAT-30 lock and key. Houses one FX-2017-12ADS Mid-Size Main Control Unit and up to 24AH batteries. Includes Red door Lobby Control Centr~Wallbox Enclosure. Supports 8 Module Footprints \/\/hite Metal Door for BB-5008 Red Metal Door for BB-5008 Custom Mountin_g Kit for BB-5008. One required per BB-5008 Lobby Control Centre Wallbox Enclosure. Supports 14 Module Footprints \1\/hite Metal Door for BB-5014 Red Metal Door for BB-5014 Custom Mounting Kit for BB-5014. One_r_e_,_u_i_re_d_,_p_e_r _B_B_-5_0_1_4 _____________ ___, NOT TO BE USED FOR INSTALLATION PURPOSES. /J;/k, Mire m .. Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com Distributed by: CAT. 5910 Rev.11 : II/J1t✓. Mircom ™ FX-2000 SERIES The FX-2000 Analog Fire Alarm Control Panel supports Programmable modules which can be connected either internally to the fire alarm panel or externally via the RAX-LCD Remote Shared Display. Connection to the RAX-LCD allows for unique configurations for a specific remote location. RAX-LCD mounted in a 88-1001 R enclosure PROGRAMMABLE MODULES RAX-LCD Remote Shared Display The RAX-LCD Remote Shared Display is a remote annunciator that provides the same functions as the main display on the fire alarm control panel, less 16 zone LEDs. It is equipped with a large 4 line x 20 character back-lit alphanumeric LCD display which uses a simple menu system complete with a directional keypad and switches for Enter, Menu, Cancel and Info. It also has 4 Alarm Queue switches and LEDs as well as common control switches and LEDs for Signal Silence, Fire Drill, System Reset, Lamp Test, General Alarm and Acknowledge. The RAX-LCD can be programmed to show different points than the main panel. In addition to being a remote annunciator, the RAX-LCD can also be used as a driver module for standard LED annunciation or reduced zone annunciation ( different from the main panel annunciation), graphic drivers programmed different from the main annunciators, programmable switch modules with their unique configuration and fan damper control also with their unique configuration. Each time a different type of annunciation configuration is required or a different location is required an additional RAX-LCD will be needed. The RAX-LCD allows for the control switches to be disabled on a per function basis (via laptop configurator) for areas that do not require certain Common Control functions to be remotely located from the Fire Alarm Control Panel. The RAX- LCD occupies one display position in the 88-1000 or 88-5000 enclosures. RAX ... 1048 PrQgrammable Zone LED Annunciator Module The RAX-1048 Programmable Zone LED Annunciator Module provides 48 programmable bi-coloured LEDs. The RAX-1048 is used if additional LED zone annunciation is required. The addressable points can be grouped together to light one LED, or they can be part of many groups and therefore may turn on many LEDs. The circuits can be selected as either Alarm to illuminate the red LED or for Supervisory to illuminate the amber LED. Any zone trouble condition will be displayed on the Shared Display. The RAX-1048 can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display if a programmable remote LED annunciator is required. It takes up two frames when connected to either the main or remote shared display. The RAX-1048 is used in conjunction with the RAX-LCD when a different type of annunciation configuration or a different location is required. The RAX-1048 occupies one display position in the 88-1000 or BB-5000 enclosures. ® S5434 @ 7165-1477: 111 (RAX-1048, IPS-2424 & FDX-008) 7120-1477:107 S5434 (RAX-LCD) MEA approved 31 3-97-E <8> APPROVEO 3017996 CATALOG NUMBER S91~ NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. FDX-008 Fa n Damper Module The FDX-008 Fan Damper Module provides individually programmed circuits which can be used for fan or damper control. Each circuit has a slide-in label, a three position selector switch, green "run or open" LED and an amber "off or closed" LED. The three-position selector switch has a centre "auto" position, a left "off or close" position and a right "on or open" position. In the 'auto' position the fan or damper follows the fire alarm programming when an alarm occurs. When the switch is turned to the 'off' position the fan or damper is turned 'off or closed'. If the fan or damper is normally 'on or open' it will turn 'off or close' when the switch is moved to the 'off' position. When the switch is moved to the 'on' position the fan or damper is turned 'on or open'. If the fan or damper is normally 'off or closed' it will turn 'on or open' when the switch is moved to the 'on' position. The 'on', 'off' and the 'auto' positions are configurabl¢ to remote addressable output modules (MIX-MS00CH) and can be configured for normally 'on or off' fans or normally 'open or closed' dampers. The LEDs can be controlled from the program or by proving switches through mini input modules (MIX-M501 M). The FDX-008 can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display when a different type of fan/damper configuration or a different location is required. The FDX-008 takes up one frame when connected to the main or remote shared display. The FDX-008 occupies one display position in the BB-1000 or BB-5000 enclosures. Ordering Information Description Remote Shared Display IPS-2424 Programmable Input Switches Module The IPS-2424 Programmable Input Switches Module, which provides 24 programmable switches complete with bi-coloured LEDs and slide-in labels, can be configured for ancillary functions such as zone by-pass or added common control functions. In a zone by- pass configuration, a group of addressable devices or hardwired circuits can be assigned to a programmable switch and when the switch is operated, those devices or zones are by-passed. The switches operate in a toggle operation for on and off. There are two LEDs for each switch; one for selection, the other is bi-coloured to indicate point status when the switch is returned to normal (unbypassed) position. The bi-coloured LED will flash red to indicate an alarm or it will flash amber to indicate that a supervisory alarm will be processed when the switch is returned to normal (unbypassed) position. The IPS-2424 can be connected to the main panel or it can be connected to the RAX-LCD Remote Shared Display if unique programmable input switches are required for a specific location. The IPS-2424 takes up two frames when connected to the main or remote shared display. The IPS-2424 occupies one display position in the BB-1000 or BB-5000 enclosures. Model RAX-LCD RAX-1048 IPS-2424 FDX-008 Programmable Zone LED Annunicator Module Programmable Input Switches Module Standby 100 mA 15 mA 10 mA 10mA Alarm 150 mA 100 mA 144 mA 100 mA Fan Damper Module NOT TO BE USED·FOR INSTALLATION PURPOSES. /i;//1"' Mircom ,· Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com ------------------, Distributed by: CAT. 5912 Rev. 7 WF2-CO SERIES LTE / IP Single or Dual Path Commercial Fire Communicators The HWF2-COM Series LTE / IP fire communicators are single or dual path commercial fire alarm communicators that offer Contact ID reporting with any FACP (fire alarm control panel) with a built-in dialer. Models include: HWF2A-COM (AT&T LTE & IP) HWF2V-COM (Verizon LTE & IP) Both models connect directly to the primary or secondary communication ports of a fire panel's digital alarm communicator transmitter COACH Three selectable reporting paths include: L TE cellular only, IP only, or IP primary with LTE cellular backup. All signals from the HWF2-COM Series are delivered to the Alarm Net® network control center which routes highly encrypted, cybersecured Ethernet data packets via a customer-provided Internet connection or LTE cellular network to the appropriate central station. The Alarm Net® network control center is fully redundant and monitored 24/7. Installation and programming are easy using the handheld 7720P Programming tool. FEATURES AND BENEFITS • !..TE: and IP conrwction tested every day • Three selectable reporting paths: LTE cellular only, IP only, or IP Primary with LTE cellular backup • Requires no change to the existing FACP configuration • Connects directly to the primary and secondary telephone ports of a DACT • Plan cho:ces ra nge from 5 minute, 60 minute, 6 hour, and 21+ hour supervision intervals • Operates over the following communication protocols: LTE, HSPA+(4G) HSPA (3G) • Works over any type of customer provided Ethernet 10/100 based network connection (LAN or WAN), DSL model or cable modem • Data transmits over standard Contact ID protoco l but is secured with the industry's advanced encryption standard (AES 256 bit) • Supports both dyna mic (DHCP) or public and private Static IP addressing • Reliable connection: IP and cellular connection tested every day • Built-in. standalone power supply module. Onboard charging circuit design accommodates battery backup. Includes primary power and battery supervision HWF2A-COM HWF2V-COM • . Diagnostic LEDs indicate signal strength and status • Choice of LTE provider services • QOS: Quality of Service diagnostics via Alarm Net conveys vital cornmunicator information including signal strength, message path used, and when the message was received • 7720P Handheld programmer for easy setup Honeywell The HWF2-COM LTE / IP fire communicators operate over the most modern an d common cellular networks including LTE, 4G and3G. They connect to any customer provided Ethernet 10/100 base network connection (LAN or WAN), DSL or cable modem. Selectable reporting path feature allows the radios to be configured for a single • Primary Subscrib er ID (four digits), obtained from your monitoring station • Communication Module MAC ID, and MAC CRC number located on the outside of the box and inside of the module All parameters are assigned by the monitoring station. or dual path, while providing appropriate supervision intervals ALARMNET based on NFPA 72 requirements. Selectable paths and supervision Alarm Net communications technology provides a highly reliable timing intervals include: alternative for the transmission of alarm signals. The network 2010 Cell Single path, cellular 5 Minutes 2010 IP Single path, IP 5 Minutes 2010 IP& Cell Dual path, IP and cellular 24 Hours 2013 Cell Single path, cellular 60 Minutes 2013 IP Single path, IP 60 Minutes 2013 IP & Cell Dual path, IP and cellular 6 Hours OPERATION When an event occurs, the FACP goes off-hook to dial the central station. The HWF2-COM Series dialer capture module detects the off-hook condition and provides the fire panel with a dial tone. When the fire panel detects the dial tone, it begins dialing the central station. After the dialing is completed, the dialer capture module returns a signal to the fire panel. The fire panel then sends the Contact ID reports to the dialer capture module, which in turn sends a signal after the report is successfully received from the fire panel. The dialer capture nodule sends the Contact ID reports to the HWF2- COM Series communications module. When all the reports are sent, the fire panel goes on-hook. The HWF2-COM Series communications module then transmits the messages to the central station either over the LTE network or the Internet (depending on configuration). FIRE COMMUNICATOR/ PANEL CAPABILITY The HWF2-COM Series is compatible with fire alarm control panels that use the Contact ID communications format as described in the SIA DC-05 standard. EASY TO PROGRAM The HWF2-COM communicator can be pre-programmed using the 7720P programmer to enter all central station information. This is saved to the HWF2-COM communicator panel memory. When the HWF2-COM is installed at the site and connected to the Internet/ Intranet, it regi sters with the AlarmNet Receiver. For most installations, the only required parameters are: • Primary City 10 (two digits), obtained from your monitoring station • Primary Central Station ID (two digits), obtained from your monitoring station Page 2 of 3 -DH-62010:B • 6/2712019 provides extensive coverage in the United States and Canada. The Alarm Net Network Control Center processes signals from powerful servers in multiple locations equipped with 24/7 infrastructure support. Redundant hardware servers, real-time backup databases, and generators with battery backup at all locations ensure continuity of service. Signals from Alarm Net are transmitted to central station receivers using multiple communication paths consisting of the Internet, LTE radio network, or toll free plain old telephone service (POTS). Visit Alarm Net.com to learn more. INSTALLATION REQUIREMENTS, UL COMPLIANCE To meet UL864/NFPA requirements, ensure the following: • HWF2-COM Series must be installed in accordance with the National Fire Protection Association (N FPA) standards 70 and 72 • HWF2-COM Series must be mounted in the same room and within 20 feet of the tire panel. • HWF2-COM Series and all equipment used for the IP connection (e.g., router, hub, modem, etc) must be UL-listed. powered from an unswitched branch ci rcuit, and be provided with appropriate standby power. • HWF2-COM Series must use the 7 AH battery (not included) to provide 2'-+ hour backup capability HWF2-COM SERIES TECHNICAL SPECIFICATIONS ELECTRICAL Transformer: • Primary: 120VAC, 60Hz, 0.5A • Secondary: 18VDC, SOVA Battery: • One 12 V 7.0 AH lea d-acid battery: (not supplied) • Battery charging cu rrent: 1 Amp maximum • Battery discharge current: Sta ndby 230mA. Active 950mA CABINET SPECIFICATIONS • Dimensions: 14.875" H x 12.75" W x 3.Q" D (37.8cm H x 32.4cm W x 7.6cm D) • Colo r: Red SHIPPING DIMENSIONS • Weight: 5.3 lbs (6.94kg) • Dimensions: 15.625" H x 13.79" W x 9.25" D (39.7 cm H x 34.9cm W x 23.9cm 0) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at O -49°C/32-120°F and at a relative humidity 93%+-2% RH (non- condensing at 32°C +-2°C(90°F +-3°F). However the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 -27°C/60-80°F. PRODUCT LINE INFORMATION HWF2V-COM: LTE Digital Cellular Fire Alarm Communicator and Internet Panel, Verizon LTE / IP HWF2A-COM: LTE Digital Cellular Fire Alarm Communicator and Internet Panel, AT&T LTE / IP Honeywell Power Products 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 ·www.honeywellpower.com Both models ir:iclude: • Red cabinet with key and lock • Wall outlet box • Dialer capture modu le • LTE communications module • An tennc1 and mounting adapter • PowerBoostl power supply • LED display boa rd • Transformer • Manual and required screws • Cables, etc. ANTENNA AND EXTERNAL HARDWARE CELL-ANT3DB: 3dBA gain antenna WA 7626-CA: SMA to N adapter cable 7626-50HC: 50 ft. antenna cable, low loss Note: The WA 7626-CA adapter cable and 7626-50HC antenna cable are only required when installing the CELL-ANT3DB antenna remotely. OTHER ACCESSORIES 7720P: HWF2V-COM, HWF2A-COM and IPGSM-4G handheld programmer HPTCOVER: Plug-in transformer box for HWF2V-COM, HWF2A-COM, and IPGSM- 4G communicators BAT-1270: Battery 12 Volts, 7 AH, sealed AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the HWF2-COM Series communicators. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult the factory for latest listings. UL Listed: S789 CSFM: 7300-1645:0511 FDNY: Approved DH-62010 I B I 06/19 <c,2019 Honeywell International Inc. THE FUTURE IS WHAT WE MAKE IT Honeywell K'J Al . ® I FireSwitch108 ;: tr O n IX : Managed NAC Power Extender Rev. DSFireSwitchl08_02082013 Overview The Altronix FireSwitchl 08 is a cost effective managed NAC Power Extender. It interfaces with 12 or 24VDC Fire Alarm Control Panels (F ACP) to provide Notification Appliance Circuit expansion support, for additional horns/strobes to allow ADA compliancy. It also pro- vides auxiliary power to support system accessories. It delivers electronically regulated and filtered 24VDC power to Class B or Class A NAC loop circuits. Additionally, a separate 1 amp auxiliary output for 4-wire smoke detectors is available. Alarm current can be divided between the eight (8) outputs for powering NAC devices. Outputs are rated at 2.5 amp max., and can ~ be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All FireSwitch108 ,/Jaf!1rnr5, A //~CH ® outputs m~y be prowamme_d for Input t~ Output Follower M?de ( rJ ~1 y y J I • ( output will follow mput. 1.e. March Time Input, March Time \,,,,,.• Output). In non-alam1 condition independent loop supervision for Class A and/or Class B F ACP NAC circuits is provided. In the event of a loop trouble, the F ACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble output terminals [NC, C, NO] which are used to indicate general loop/system trouble. Two (2) FACP signaling outputs can be employed and directed to control supervision and power delivery to any combination of the eight (8) outputs. It provides a programmable LCD display interface, plus an ethemet port interface for remote programmability and monitoring. Specifications Input: • Power input: 120V AC 60Hz, 4.8 amp. • Two (2) Class A or two (2) Class B F ACP inputs. • Two (2) configurable inputs trigger via Class A or Class B F ACP signal circuits (polarity reversal) or dry contacts. Output: • 24VDC voltage regulated power-limited NAC outputs. • Output power: 10 amp max. total alarm cmTent. 7 amp max. stand-by without battery back-up. 1 amp with battery back-up including dedicated Aux. output. For Canadian applications Stand-by with battery backup is limited to 0. 45 amp. • 2.5 amp max current per output. • One ( 1) auxiliary output rated at 1 amp (regulated, battery backed up). 0.45 amp for Canadian applications. • Any NAC can be configured as an Aux. output with or without battery back-up (special application only). When set as Aux. output, the output is not supervised. • Programmable supervised indicating circuit outputs: Eight (8) Class B or Four (4) Class A, or any combination of Class A and Class B circuits. • Thermal and short circuit protection with auto reset. Battery Backup: • Built-in charger for sealed lead acid or gel type batteries. • Automatic switchover to stand-by battery when AC fails. • Zero voltage drop when switching over to battery backup. Supe,vision: • AC fail supervision (form "C" contacts). • Battery fail & presence supervision (form "C" contacts). • Low power shutdown. Shuts down DC output terminals jf battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge. Special Features: • Programmable LCD display interface. • Ethernet port interface for remote programmability and monitoring. • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate. • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit). • Compatible with 12VDC or 24VDC fire panels. • Output loop supervision directed to input 1 or input 2. • Common trouble Dry N.C. output for reporting trouble to remote FACP. • Ground fault detection -Ground fault maximum test impedance 1,000 ohm. • Ground fault Dry N.O. output to report ground fault to remote F ACP. Electrical: • Operating temperature: 0° C to 49° C ambient. • BTU/Hr.: 122.84 BTU/Hr. • System AC input VA requirement: 576VA. Visual Indicators: • LCD display -Indicates troubles and conditions of operation. Trouble Condition Memory facilitates quick identification of an intermittent/fault (short circuit, open or ground) which has previously occurred on one or more signaling circuit outputs. LCD displays which output the fault has occurred on. Mechanical: • Enclosure Dimensions (H x W x D approx.): 15.5" (393.7mm) x 12" (304.8mm) x 4.5" (114.3mm) -Accommodates up to two (2) 12VDC/12AH batteries. • Product weight (approx.): 12.4 lbs. (5.62 kg). • Shipping weight (approx.): 13.7 lbs. (6.21 kg). Agency Approvals UL Listed Control Units and Accessories for NFP A 72 Compliant. Fire Systems (UL 864). CAN/ULC-S527-99 Control units for Fire Alarm Systems. (~~\ CSFM -California State Fire Marshal \;f}~-' Approved. I IS' (38.1mm) 2.0" (50.8mm) 1Q'" (50~8mm) 5.0" (127.0111ml 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 L'======!=== kl.25" (31.75mm) I .91'" Enclosure Dimensions CH x W x D) (approximate): 15.5" (393.7mm) x 12" (304.8mm) x 4.5" (114.3mm) (38.im;, (117.22mm) (117.22mm) I I 5" i------4.615" ----+----4.615'" f-------------12.23"'-----------~ -1.1"-;j (310.64mm) 1-1.1·· 127.%111111 127.9-lrmn)j I I 7 1.75" (44.45mm) I 0.91" '61.375" (34.925mm) '61.125" (28.575mm) 0 (23. l14mml _(S (S i23.114mml r---i- 15.5' (393.7m m) 0 ~ -n LQ.79" 1-11"-I (27q.Jmm) (20.06m m) 1.75" (44.45mm) '----+-------+-------+------'_J_ ll.5"---t----4.615'"----+----4.615"-----!-1.5'' ~ (38.1mm) (117.22mm) (117.22mm) (38.1mm) Altronix Corp.~ 140 58th Street, Brooklyn, NY t 1220 • ?lS..567-8181 • 888,,.258-7669 • altronix.cmu f---'<--_,,._-4.5"-----l (114.3mm) -l.25" (3l.75mml 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I 1.5" (38.1mm) ADVANCED PROTOCOL INTELLIGENT SMOKE SENSORS MIX-1251AP/MIX-2251AP Model MIX-2251AP sensor mounted in a B210LP base Description Mircom's low profile intelligent plug-in smoke detectors with integral communications provide features that surpass conventional detectors. Sensitivity is continuously monitored and reported to the panel where the desired detector sensitivity can be programmed. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations for selective maintenance when chamber contamination reaches an unacceptable level. Mircom's Advanced Protocol (AP) devices use a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. Mircom'sAdvanced Protocol uses a superior group polling method as well as an interrupt feature that provide for a faster response to an alarm condition. In addition, the Advanced Protocol allows for greater system capacity with support for up to 318 devices per SLC circuit. The AP devices are backwards compatible to operate in CLIP mode for legacy system applications. MIX-1251AP Intelligent Ionization Smoke Sensor The MIX-1251AP ionization sensor incorporates a unique single source, dual chamber design to respond quickly and dependably to a broad range of fires. MIX-2251AP Intelligent Photoelectric Smoke Sensor The MIX-2251AP provides a unique optical sensing chamber that senses smoke produced by a wide range of combustion sources. Features Sleek, low profile design Available with photoelectric or ionization technology Photoelectric detectors are available with additional fixed temperature detection Dual LEDs indicate communications and activate steady when in alarm Low profile base provides easy interchangeability Low standby current Rotary switches for direct-dial entry of address. Each unit can have address set for 01-159 for Advanced Protocol mode and 01-99 for CLIP mode Magnetic test feature Superior EMI protection Sealed against dirt, insects, and back pressure MIX-2251TAP Intelligent Photoelectric Smoke Sensor with 135°F Fixed Temperature Heat Detector The MIX-2251TAP adds dual electronic thermistors to the MIX-2251AP to provide 135°F (57°C) fixed temperature thermal sensing. MIX-2251 TMAP Intelligent Acclimate TM Multicriteria Smoke Sensor The MIX-2251TMAP is a photoelectric smoke detector with supplementary 135°F thermal. Also known as Acclimate TM, it uses advanced on-board software to combine the signals from the photo and thermal elements. The MIX-2251TMAP is a true multicriteria detector capable of rejecting nuisance sources, but still responding quickly to real fires. Acclimate has the capability of adjusting its sensitivity according to the type of environment that it is installed in.and rate- of-rise thermal detection. These thermal detectors provide cost effective, intelligent property protection in a variety of applications. S6295 S6965 7271-1477:0159 (MIX-1251APJ 7272-1477:0161 (MIX-2251APflAPITMAP) CATALOG NUMBER 5952 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Specifications 15 to 32 voe Photoelectric models: 5.2 o Ionization m f't;lAAra~n.i:JJlSI 10% -93% non-condensing ·;~~fad' .. MIX-1251AP/MIX-2251AP: 32°F to 120°F (0°C to 49°C) MIX-2251TAP/MIX-2251TMAP: 32°F to 100°F (0°C to 38°C) 2.0 inches (51 mm) ;;~t ...• t:.i:§!ij~,:~,t:.1:i?i~;J\jggf \)1';1~;'.········.· Ion: 0 -1200 fpm (0 -6.1 m/sec) 6.1 inches (155 mm) installed in B210LP Base 4.1 inches (104 mm) installed in B501 Base Photo/Photo with Thermal: 0 -4000 fpm (0 -20 m/sec) (suitable for installation in ducts) Ordering Information MIX-1251AP Intelligent Ionization Smoke Sensor MIX-2251AP Intelligent Photoelectric Smoke Sensor MIX-2251TAP Intelligent Photoelectric Sensor with 135°F Fixed Temperature Heat Detector MIX-2251TMAP Intelligent Acclimate™ Multicriteria Smoke Sensor B501 Intelligent Flangeless Mounting Base B210LP Intelligent Flanged Mounting Base B224RB Intelligent Relay Base B224BI Intelligent Isolator Base B200SR },~ij4~~sori~s . Intelligent Standard Sounder Base (Compatible wih B501 BH Series) RA-100Z Add suffix '~" for ULC listed model. NOT TO BE USED FOR INSTALLATION PURPOSES. Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-46~5 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com Distributed by: CAT 5952 Rev. O ADVANCED PROTOCOL INTELLIGENT THERMAL SENSORS MIX-5251AP/RAP/HAP Model MIX-5251AP sensor mounted in a B210LP base Description Mircom's low profile intelligent plug-in thernal detectors with integral communications provide features that surpass conventional detectors. Point ID capability allows each detector's address to be set with decade address switches, providing exact detector locations. These intelligent sensors utilize a state-of-the-art thermistor sensing circuit for fast response and are designed to provide open area protection with 50 foot spacing capability. · Mircom's Advanced Protocol (AP) devices use a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. Mircom's Advanced Protocol uses a superior group polling method as well as an interrupt feature that provide for a faster response to an alarm condition. In addition, the Advanced Protocol allows for greater system capacity with support for up to 318 devices per SLC circuit. The AP devices are backwards compatible to operate in CLIP mode for legacy system applications. MIX-5251AP Intelligent Heat Detector, 135°F Fixed Temperature The MIX-5251 AP uses an innovative thermistor sensing circuit to produce 135°F fixed temperature detection in a low profile package. This thermal detector provides cost effective, intelligent property protection in a variety of applications. Features Sleek, low profile design Available as 135°F fixed temperature, 135°F fixed temperature with rate-of-rise detection and high temperature 190°F fixed temperature Dual LEDs indicate communications and activate steady when in alarm Low profile base provides easy interchangeability Low standby current Rotary switches for direct-dial entry of address. Each unit can have address set for 01-159 for Advanced Protocol mode and 01-99 for CLIP mode Superior EMI protection Sealed against dirt, insects, and back pressure MIX-5251 RAP Intelligent Heat Detector, 135°F fixed temperature with Rate-of-Rise Detection The MIX-5251 RAP provides both 135°F fixed and rate-of-rise thermal detection. This thermal detector provides cost effective, intelligent property protection in a variety of applications. MIX-5251 HAP Intelligent High Temperature Heat Detector, 190°F Fixed Temperature The MIX-5251 HAP provides 190°F (88°C) fixed temperature detection for high temperature applications. ~®@ S6299 S7498 7270-1477:0160 CATALOG NUMBER 5953 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Specifications Fixed Temperature Setpoint: 135°F (57°C) Rate of Rise Detection: 15°F/min. (8.3°C/min.) High Temperature: 190°F (88°C) 6.1 inches (155 mm) installed in 821 OLP Base 4.1 inches (104 mm) installed in 8501 Base MIX-5251AP/MIX-5251 RAP: -4°F to 100°F (-20°C to 38°C) MIX-5251 HAP: -4 °F to 150°F (-20°C to 66°C) Ordering Information Intelligent Heat Detector, 135°F Fixed Temperature with Rate-of-Rise Detection Intelligent High Temperature Heat Detector, 190°F Fixed Temperature 8501 Intelligent Flangeless Mounting Base B210LP Intelligent Flanged Mounting Base B224RB Intelligent Relay Base 822481 Intelligent Isolator Base B200SR Intelligent Standard Sounder Base (Compatible wih 8501 BH Series) Add suffix •~" for ULC listed model. NOT TO BE USED FOR INSTALLATION PURPOSES. Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com Distributed by: CAT. 5953 Rev.1 ~~SYSTEM C~ SENSOR' 200 Series Mounting Base Options System Sensor mounting bases and kits provide a variety of installation options tor detectors in any application. Features • Bases enable quick and secure detector plug-in • SEMS screws provide easy wiring connection • Support for 12-24 AWG provides installation flexibility • Multiple accessory options provide mounting flexibility • Sounder bases are compliant with UL 464 and UL 268 Agency Listings Model Listings B501 UL, ULC,* FM, CSFM B210LP UL, ULC, FM, CSFM B200S UL, ULC, FM, CSFM B200SR UL, ULC, FM, CSFM B224RB UL, ULC, FM, CSFM B224BI UL, ULC, FM, CSFM * For ULC-listed products, add "A" to the model number (e.g., B501A). To meet local code and application requirements, System Sensor offers relay, isolator, and sounder base options for 200 Series detectors. Relay bases provide one form C contact relay for control of auxiliary functions, such as door closure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in a combination temporal 3 and continuous tone model (B200SR) or an addressable model (B200S) that can be activated by the fire alarm control panel based on the event.t 200 Series Bases provide a variety of mounting options to meet your installation challenges. Bases come in flanged or flangless versions for mounting to a variety of junction boxes. See the 200 Series Junction Box Selection Guide on the next page for junction box options. Surface mounting boxes are also available. t Consult your fire alarm control panel manufacturer for compatibility with the addressable model of the sounder base. Specifications -200 Series Bases Physical Specifications Diameter 8501: 4.1" (104 mm); B210LP: 6.1" (155 mm); 822481, B224RB, 8200SR, 8200S: 6.875" (175 mm) Wire Gauge 822481, 8224RB, 8200SR, 8200S, 8210LP, 8501: 24 to 12 AWG Temperature Range Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at system sensor.com Humidity Range 10% to 93% RH non-condensing ,B224RB/B224Bf Electrical Ratings B200SR/B200S Elettrical Ratings Operating Voltage Standby Current Set Time (B224RB only) 15 to 32 voe (powered by SLC) 170/450 µA max. Short Delay: 60 to 100 msec Long Delay: 6 to 1 0 sec Reset Time (8224RB only) 20 msec max. Relay Characteristics (8224RB only) 2 coil latching relay 1 Form C contact UUULC Rating: 0.5 A@ 125 VAC o.9 A@ 125 voe 3 A@3o voe 200 Series Junction Box Selection Guide External Supply Voltage 16 to 33 voe (VFWR) Standby Current Sound Output Alarm Current 500 µA max. Greater than 90 dBA measured in anechoic room at 10 feet, 24 volts. 85 dBA minimum in UL reverberant room 35 mA max. Single 3.5° 4" 4° 4" 50 60 70 75 -Model Gang Octagonal Octagonal Square Square* mm mm mm mm 8501 No Yes No No Yes Yes Yes Yes No 8210LP Yes Yes Yes Yes Yes No No Yes No 8224RB Yes No Yes Yes Yes No No Yes No B224BI Yes No No Yes Yes No No Yes No B200SR/B200S Yes Yes1 Yes Yes Yes 1 No No Yes No * with 3.0" mud ring t B200SA is not compatitble with this junction box Note: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. Ordering Information, 200 Series Bases 82005 Addressable Sounder Base Model Description B501* B501BP* B210LP* B210LPBP* B200SR* B200S* 4" Flangeless Mounting Base 4" Flangeless Mounting Base Bulk Pack 6" Flanged Mounting Base 6" Flanged Mounting Base Bulk Pack Standard Sounder Base (Compatible with B501 BH Series) Intelligent Addressable Sounder Base B224RB* Relay Base B224BI* Isolator Base 200 Series Accessories SMB600 Surface Mounting Kit (flanged) F110 Accessory Flange Ring for 6" Base F11 0BP Accessory Flange Ring for 6" Base Bulk Pack F210 Accessory New Smaller Flange Ring for 6" Base RA100Z* Remote LED Annunciator M02-04-00 Detector Test Magnet M02-09-00 Test Magnet with Telescoping Handle XR2B Detector Removal Tool (T55-127-000 included) XP-4 Extension Pole for XR2B (5 to 15 ft.) T55-127-000 Detector Removal Head BCK-2008 Black Detector Kit WCK-200B White Detector Kit * Add "A" to model number for ULC-listed product (e.g., B501A) Product Overview When used with compatible fire alarm control panels, the B200S sounder base provides unmatched flexibility to configure the output to various events. When combined with System Sensor SpectrAlert® Advance notification appliances, the B200S can serve as a UL464 compliant component of the general evacuation signaling, improving aesthetics and reducing system costs. Features*: • Simple addressing scheme -base adopts the same address as attached sensor • Synchronizable with SpectrAlert Advance notification appliances • Four standard tone patterns at two selectable volumes • Custom tone capability • Support for Temporal-4 CO annunciation * Note: Some features are dependent on Fire Alarm Panel programming. Consult your Fire Alarm Panel manual for more information on the capabilities of your system. 3825 Ohio Avenue • St. Charles, IL 6017 4 Phone: 800-SENSOR2 • Fax: 630-377-6495 www. system sensor. com ©201 2 System Sensor. Product specifications subject to change without notice. Visit systemsensor.ccm for current product information. including the latest version of this data sheet. SPDS13801 • 09/12 METAL FIRE ALARM STATION MS-701 Single Action Manual Station MS-710U Dual Action Manual Station Description Mircom's MS-700 Series Manual Stations provide manual fire reporting. These high quality, die-cast metal manual stations are available in either single or dual action configurations with SPST contacts and terminal strip connections. The normally open contact, which closes when the manual station is activated, is rated for 1 amp, 30 VDC. The contacts are gold plated to avoid the risk of corrosion. The MS-700 Series Manual Stations are available in many different configurations as either single or dual- action devices. The MS-701 is a single action, single stage manual station. Model MS-710 is a single stage, dual action manual station. The MS-702 (two stage) is similar to the MS-701 (single stage) except it contains an additional General Alarm (G.A.) N.O. switch. For safety reasons, the G.A. switch is only accessible after the handle has been pulled. A special key is supplied with each unit. All models are available with key resets, terminal connectors, SPST gold contacts and CAT-30 lock and keys. The units mount on a standard single gang backbox, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox. The MS-700U Series Manual Stations are listed for outdoor applications when used with the 88-?00WP. MS-700 SERIES Features Single or Dual Action models Single Stage or Dual Stage models Key resettable Terminal connectors Gold plated SPST contacts Optional auxiliary contacts High-gloss red enamel finish Plastic breakrod Mounts on standard single gang box, Mircom's BB- 700 surface metal backbox or BB-?00WP weather proof backbox Available in English and Bilingual versions Operation The MS-700 Series is operated by pulling the handle on the front of the station. The unit is reset by opening the station with the key, placing the handle in the normal upright position and re-locking the station. On the dual action models, the push bar rotates inward allowing the Manual handle to be grasped in a one handed motion. The MS-702 (two stage version) also provides a key switch which is accessible after the handle has been pulled. Operation of the key switch, when connected to a separate general alarm circuit, will initiate the 2nd stage of a two stage alarm signalling system. Specifications The manual station shall be Mircom's MS-700 Series. Operating instructions shall be in raised English or English and French lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the alarm detection circuit. In addition, those stations installed in a two stage system shall come equipped with an internal key switch designed to operate the 2nd stage alarm initiating circuit. All manual fire alarm stations shall be installed to comply with the Canadian Electrical Code (CSA22.1) and CAN/ULC-S524-01 Standard for Installation of Fire Alarm Systems. Final acceptance is subject to the local authority having jurisdiction. MEA approved S7005 S7005 7150-1477:128 313-97-E CATALOG NUMBER 5156 NOT TO BE USED FOR INSTALLATION PURPOSES. l/lircom reserves the right to make changes at any time without notice in prices. colours, materials, components, equipment. specifications and models and also to discontinue models. Specifications Switch Rating: Manual Station Dimensions: Colour: Typical Wiring Diagrams 1 Amp@ 30 voe, 0.1 Amp@ 125 VAC 4.9" H x 3.5" W x 2.0" D Red with raised white letters, white manual bar with raised black letters. MS-701, MS-702 and MS-710 MS-705 and MS-715 FROM { } TO NEXT STATION PREVIOUS OR END OF LINE STATION -----1----...--... ------4----DEVICE SPDT Switch Terminal Block FROM { } TO NEXT STATION PREVIOUS OR mo OF LINE STATION DEVICE (MS-702 ONLY) (MS-702 ONLY) N.O. KEYSWITCH MS-702 ONLY -Lj N.O. SWITCH SEE NOTES. MS-707 and MS-708 SPOT Switch #1 Terminal Block COM COM NO Red 00 r I Black NC:: UN I -~- ! □CS) White C DC~ I SEE NOTES. _L.. • ----NO Switch Surface Mount Backboxes NO ---+--_R_e_d __ -----i l]c;) NC•---····--·· ___ ____i B/ack -□-"1(\\-,1-----1 '----+--------'Whit~ ---00) BB-700 Surface Mount Backbox Dimensions: SPOT Switch #2 COM NO __ ---i_R_ed _ __, NC ---+-B_la_c_k_, White N.O. Keyswitch (MS-708 Model Only) Black Black 1--=-0(S)-,--_'_ 5" H x 3.6" W x 2.0" D SEE NOTES. NOTES: Wire as shown so that supervision of connections is maintained Mount station to 2" x 4" x 2¼" outlet box BB-700WP Weatherproof Surface Mount Backbox Maximum size: No. 12 AWG For Normally Open operation, cut the NC wire For Normally Closed operation, cut the NO wire Switches shown in the Station Closed position Ordering Information Model Description MS-701 Single Stage Single Action Manual Station (Bilingual) MS-702 Dual Stage Single Action Manual Station (Bilingual) Dimensions: 5" H x 3.6'' W x 2.2" D MS-705 Single Stage Single Action Manual Station dw one additional Form "C" (SPOT) Contact (Bilingual) MS-710 Single Stage Dual Action Manual Station (Bilingual) MS-715 Single Stage Dual Action Manual Station c/w one additional Form "C" (SPOT) Contact (Bilingual) Note: Add suffix "U" for English only models. MS-707 Single Stage Single Action Manual Station c/w 2 Form "C" Contacts MS-708 Dual Stage Single Action Manual Station c/w 2 Form "C" Contacts and Key Switch BB-700 Series 700 Interior Surface Mount Backbox, Red Finish BB-700WP Series 700 Weatherproof Surface Mount Backbox, Red Finish /J/k, Mircom , Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 Web page: http://www.mircom.com NOT TO BE USED FOR INSTALLATION PURPOSES. U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Email: mail@mircom.com Distributed by: !SC) 9()() 1 :20()8 i-~ttJf~) ~ tkt:L) CAT 5156 Rev. 6 · l/1111✓. M ircom ™ ADVANCED PROTOCOL INTELLIGENT MONITOR MODULES MIX-M500AP SERIES Description Mircom's intelligent monitor modules are designed to meet a wide range of applications. The monitor modules provide an interface to contact devices, such as, manual stations, conventional smoke or heat detectors, waterflow switches, and more. The monitor modules are addressed with easy-to-use rotary code switches. Mircom's Advanced Protocol (AP) devices use a high speed communication protocol that greatly increases the speed of communication between the intelligent devices. Mircom'sAdvanced Protocol uses a superior group polling method as well as an interrupt feature that provide for a faster response to an alarm condition. In addition, the Advanced Protocol allows for greater system capacity with support for up to 318 devices per SLC circuit. The AP devices are backwards compatible to operate in CUP mode for legacy system applications. MIX-MS00MAP Monitor Module Mircom's MIX-MS00MAP monitor module is a standard- sized module that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. The MIX-MS00MAP is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary decade switches. It provides either a 2-wire or 4-wire fault tolerant initiating circuit for normally open contact fire alarm, supervisory, or security devices. The module has a panel controlled LED indicator. Features Designed to meet a wide range of applications SEMS screws for easy wiring Panel controlled status LED (except MIX- M501 MAP) Rotary switches for direct-dial entry of address. Each unit can have address set for 01-159 for Advanced Protocol mode and 01-99 for CLIP mode (except MIX-MS00X) Low standby current Mount in 4" square junction box MIX-M501MAP Mini Monitor Module The MIX-M501 MAP is a miniature monitor module that supervises a Style B (Class B) circuit of dry-contact input devices. The small size of the module allows it to fit inside devices or junction boxes behind devices. The MIX-M501 MAP is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary decade switches. It provides a twowire initiating circuit for normally open contact fire alarm and security devices. MIX-M502MAP Zone Interface Module The MIX-M502MAP Zone Interface Module is a standard- sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class 8) circuit. The module allows Mircom's intelligent panels to interface and monitor two- wire conventional smoke detectors. All two-wire detectors being monitored must be UL or ULC compatible with the module. The MIX-M502MAP is addressed through the communication line of an intelligent Mircom system. It transmits the status of one zone of two-wire detectors to the fire alarm control panel. Status conditions are reported as normal, open, or alarm. The interface module supervises the zone of detectors and the connection of the external power supply. S5434 S5434 7300-1477:0157 CATALOG NUMBER 5950 NOT TO BE USED FOR INSTALLATION PURPOSES. 1ircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. MS00X Isolator Module The M500X Isolator Module is a standard-sized module that enables part of the communications loop to continue operating when a short circuit occurs on it. An LED indicator blinks in the normal condition and turns on during a short circuit condition. Specifications MIX-M500MAP Monitor Module Tetytp~rcitllt~:F{ijngtf + 32'F to 120'F (0'e to 49'e) 10% to 93% Non-condensing 4.5" H X 4" W X 1.25" 0 MIX-M502MAP Zone Interface Module Ordering Information :::\Vl~jft•··•·\\·•}ijj MIX-M500MAP MIX-M501 MAP 15 to 32 voe 5.1 mA (LED on) 400µA, 1 communication and 1 LED flash every 5 seconds, 3.9k EOL 3.9K Ohms 10% to 93% Non-condensing 4.5" H x 4" W x 1.25" 0 Monitor Module Mini Monitor Module MIX-M502MAP Zone Interface Module MIX-M500X Isolator Module Add suffix "A" for ULC listed model. The module will automatically restore the entire communications loop to the normal condition when the short circuit is removed MIX-M501 MAP Mini Monitor Module ffl~fnal~p,,ajif1g,o. 15-32 voe . ~Y~t~9~·()pi~?firjg'.~u!ti~f/C: !e~i~• ;e~~~d~~~1:~~L lt!ltR~siJti~aei 47K Ohms 40 Ohms 11 Volts 400µA ., ............ ,,,,,,,, ... , ...... ,,, .. , 32°F to 120°F (0°e to 49°e) MS00X Isolator Module 10% to 93% Non-condensing 1.3" H x 2.75" W x 0.65" D 15 -32 voe 450 µA (not isolating) 17mA (device in isolation) 32°F to 120°F (0°e to 49 °e) 10 to 93% Non-condensing 4.5" H x 4" W x 1.25" 0 NOT TO BE USED FOR INSTALLATION PURPOSES. Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 Web page: http://www.mircom.com U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Email: mail@mircom.com Distributed by: CAT 5950 Rev.1 Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modem aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12-or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING ® LISTED S5512 S4011 <8> APPROVED FM approved except for ALERT models 3057383 I . ' 7125-1653:0504 7135-1653:0503 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS868-02 • 12/01/2017 • Page 3 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to:a standard 4 x 4 x 1½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model ___ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Hom Strobe Combination The horn strobe shall be a System Sensor L-Series Model ___ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Pbysical/Eleetrioal Specifications Standard Operating Temperature Humidity Range Strobe Flash Rate Nominal Voltage Operating Voltage Range2 Operating Voltage Range (MDL3) Input Terminal Wire Gauge Ceiling-Mount Dimensions (including lens) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) Notes: 32°F to 120°F (0°C to 49°C) 10 to 93% non-condensing 1 flash per second Regulated 12 voe or regulated 24 DC/FWR1 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) 12 to 18 AWG 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 ed. AVDS868-02 • 12/01/2017 • Page 2 UL Current Draw Data UL; Max. Strobe Current Draw (mA RMS) · l.111. Max. Hom'<:!urrent Draw (mA RMS} 8-17.5 Volts 16-33Volts 8-17.5 Volts 16-33Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 NIA 111 142 Non-Temporal High 43 47 54 95 NIA 134 164 Non-Temporal Low 29 32 54 115 NIA 158 191 3.1 KHz Temporal High 39 41 54 150 NIA 189 228 3.1 KHz Temporal Low 29 32 54 177 NIA 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 tJLi Max. Current Draw {mA RMS). ceiling florn StroR,, eandela Range (1S+l17'7 eel) 8-17.5 Volts 16-33Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Hom Strobe Output (dBA) · " 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 L-Series Dimensions 6.83" diam. (173mm) 2.47" (62.7 mm) ------,--------- 1.37" (34.8 mm) Ceiling-Mount Horn Strobes 2-Wire Ceiling Mount Hom Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Mot.tel Description -. . . , . Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White A0545-00 For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications".- 6.92" diam. _ (175.77 mm) I--25" 1 I (64mm) 0 Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Hom Strobes with Ceiling Surface Mount Back Box Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White A0546-00 3825 Ohio Avenue • St. Charles, IL 6017 4 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.c001 for current product information, including the latest version of this data sheet. AVDS868-02 • 12/01/2017 Indoor Selectable- Output Low Frequency Sounders and Low Frequency Sounder Strobes System Sensor L -Series audible visible notification products are rich with features guaranteed to maximize profits with lower current draw and modern aesthetics. Features • 520 Hz ± 10% square wave tone, NFPA compliance • Full candela range plus High/Low tone options to optimize current draw for a wide variety of applications • Compact, standard, and round ceiling options • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Rotary switch for High and Low, Temp3 and Temp4 settings • Plug-in design with minimal intrusion into the back box • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices (Direct replacement for HW/R-LF and P2R/WH-LF) • Compatible with MDL3 sync module • Sounders listed for ceiling and wall mounting • Sounder Strobe listed for wall mounting • Updated modern aesthetics Agency Listings SIGNALING @ LISTED S4011 <&> APPROVfD PR452768 rii ~ Horns only: 7135-1653:0516 Horn/Strobes 7125-1653:0517 The L-Series offers the most versatile and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, listed for wall and ceiling mounting, L-Series Low Frequency can meet virtually any application requirement. The low frequency sounder and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that require a low frequency notification appliance that operates within frequency range of 520 Hz± 10% and is of a square wave tone. Like the entire L-Series product line they include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, L-Series uses a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, 24- volt operation, and a rotary switch for 520 Hz low frequency sounder tones. AVDS910-01 • 10/1/2019 • Page 1 L-Series Specifications .Architect/Engineer Specifications General L-Series low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 1½-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/s-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with _the Sync•Circuit Module, 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit (0°C to 49°C) from a regulated DC or full-wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, 185. The field selectable tones will sound within the frequency range of 520 Hz ± 10% square wave tone and have a permanent marking on the housing that reads "low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor L-Series Model ___ listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync•Circuit™ MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 24 volts (includes•fire alarm panels with built-in sync). When used with the Sync•Circuit Module MDL3, 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three or temporal four pattern, non- temporal (continuous) pattern and coded supply within the frequency range of 520Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or non-coded power supply with high and low volume settings. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor L-Series Model ___ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three or temporal four pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply with high and low volume settings. The field selectable tones will sound within the frequency range of 520 Hz ± 10% square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/a-inch back box. The module shall also control two Class B circuits or one Class A circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature Humidity Range Frequency Range Strobe Flash Rate Nominal Voltage Low Frequency Sounder Nominal Voltage Range Low Frequency Sounder Strobe Operating Voltage Range Operating Voltage Range MDL3 Sync Module Input Terminal Wire Gauge Dimensions Wall Sounder Strobe (including lens) Standard Wall Sounder Compact Wall Sounder Ceiling Sounder Standard Wall Sounder with SBBRUSBBWL Surface Mount Back Box Compact Wall Sounder with SBBGRL/SBBGWL Surface Mount Back Box Low Frequency Ceiling Sounder with SBBCRUSBBCWL Surface Mount Back Box Notes: 32°F to 120°F (0°C to 49°C) 10 to 93% non-condensing 520 Hz ± 10% 1' flash per second Regulated 24 DC/FWR1 Regulated 24 VDC/FWR1 16 to 33 V (24 V nominal) 16.5 to 33 V (24 V nominal) 12 to 18 AWG 5.6" L x 4.7" W x 1.9" D (142 mm L x 119 mm W x 49 mm 0) 5.6" L x 4.7" W x 1.5" D (142 mm L x 119 mm W x 38 mm 0) 5.25" L x 3.46" W x 1.5" D (133mm L x 88mm W x 38mm 0) 6.8" diameter x 1.4" high (173mm diameter x 36mm high) 5.7" L x 4.8" W x 3.3" D (145 mm L x 120 mm W x 87 mm 0) 5.4" L x 3.6" W x 3.0" D (137 mmL x 91mm W x 76 mm 0) 6.9" diameter x 3.9" high (175mm diameter x 99mm high) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. AVDS910-01 • 10/1/2019 • Page 2 UL Current Draw and Sound Output Data Low Frequency Wall Sounder Strobe Current Draw {mA) and Souna Output (dBA) Current Draw (mA) Volume 16-33 VDC Pos Tone Setting 15cd 30cd 75cd 95cd 110cd 135cd 1 Temporal 3 High 98 115 158 173 182 212 2 Temporal 3 Low 98 102 141 162 173 202 3 Temporal 4 High 98 108 137 151 178 202 4 Temporal 4 Low 102 104 122 136 163 187 5 Continuous High 141 158 198 216 234 264 6 Continuous Low 120 128 179 196 215 244 UL Ma~. Low Fr~ueney Sounder Current Draw (mA RMS) Current Draw Sound .. (mA) Output (dBA) Reverberant Volume 16-33 Volts 16-33 Volts Pos Tone Setting DC FWR DC FWR 1 Temporal 3 High 108 150 80 80 2 Temporal 3 Low 78 76 76 . 76 3 Temporal 4 High 111 151 80 80 4 Temporal 4 Low 80 76 76 76 5 Continuous High 111 151 80 80 6 Continuous Low 80 76 76 76 7 Coded High 111 151 80 80 8 Coded Low 80 76 76 76 *NOTE: For coded tones, temporal coding must be provided by the NAC. If the NAC voltage is held constant, the sounder output will remain constantly on. Coded ratings provided are for continuous voltage. 185cd 15cd 30cd 266 136 153 255 150 150 252 200 198 237 176 174 305 190 207 285 165 182 Sound Output (dBA) 16-33 FWR 16-33 V 75cd 95cd 110cd 135cd 185cd DC FWR 188 206 228 258 304 80 80 176 194 216 242 280 76 76 169 188 212 242 290 80 80 154 173 197 227 275 76 76 249 268 289 321 368 80 80 226 244 266 297 342 76 76 AVDS910-01 • 10/1/2019 • Page 3 L-Series Dimensions Wall LF Sounder Strobe ¢6830 r 1438 Ceiling LF Sounder Part No. Description , -· - Red White Low Frequency Sounder Strobes P2RL-LF P2WL-LF LF Sounder Strobe, Wall Low Frequency Sounders HRL-LF HWL-LF HGRL-LF HGWL-LF HCRL-LF HCWL-LF Accessories MDL3R MDL3W SBBRL SBBWL SBBCRL SBBCWL SBBGRL SBBGWL LF Sounder, Wall Compact LF Sounder, Wall LF Sounder, Ceiling Sync•Circuit™ Module, UL-listed Surface Mount Back Box, Wall Surface Mount Back Box, Ceiling Surface Mount Back Box, Wall , Compact 3825 Ohio Avenue • St. Charles, IL 6017 4 Phone: 800-SENSOR2 • Fax: 630-377-6495 Wall LF Sounder 3.455 1.453 5265 Compact Wall LF Sounder System Sensor® is a registered trademark and Sync•Circuit'M is a trademark of Honeywell International, Inc. ©2019 System Sensor. Product spec1ficat1ons subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS910-01 • 10/1/2019 ELECTROMAGN:ETIC FIRE DOOR HOLDERS DH SERIES DH ( )SPC DH ( )FDBR RSG Security 2700 Junipero Ave Signal Hill CA, 90755 www.rsgsecurity.com Tel: (562) 529-5100 Fax: (562) 529-5102 DH( )FB (Brass Plated) DH { )FPC {Flush Mount) (Surfac,e Mount) DH( )GPC1 (Ground Mount} DH( )RPC (Recessed) Description: OH series fire door holders are constructed of the finest materials and workmanship available. The door holder is made of durable die-cast met.al and offered in a high luster powdercoat finish. Other features include standard dual vottage a.c or de inputs of 12 & 24\l 24 & 120V and 24 & 220V models. While reducing stockjng requirements~ model 24120 draws a mere .020 ma. @. 24VDC lowering overall job costs, (In large instaUations the cost savings can be substantlal). Other features: single or double coil floor mounting, surface mounting and direct wall mounUng. No brackets are required. The DH series door hotder offers a new installation technique using an adhesive template assuring alignment without secondary adjustments. Accessories include extension and misalignment rods (various lengths) enabling parallelism between door and wait at distances greater than 12 inches and misalignment over 4 inches. Aiding in installation is the a.lrcratt quahty DH drm that reduces installation time and provides a near perfect aHgnment of catch~ ptate and armature -agairt lowering overall installation costs. Basic uni1s offer superior holding force and low residua~ magnetism. Models 1224 and 24120 can operate at higher listed voltages producing hoJdir,g forces in excess of 1001bs➔ (45.3kg,) For special. apptlcations. Extension Rod Applicati:ons fMi •f".'~:] 'h!:..i •r •···· L.. , ... :r .. U..$= OPTIONAL FEATURES POWDERCOATED FfMSHES (;~} • > ,',_,"'.t '"'-··~{fifwr;·····J EXTENSION AND MISAUGNMENT RODS SURFACE MOUNT BACK BOX TIME SAVING DRILL FIXTURE (FOR MOUNTING CATCH PLATE) MADE IN AMERICA Dual Voltage (rear view shov.in) STANDARD FEATURES VERY LOW CURRENT DRAW DUAL VOLTAGE INPUTS TERMJNAL BLOCK CONNECTIONS HIGH HOLDING FORCE LOW RESIDUAL MAGNETISM MOUNTING HARDWARE & INSTRUCTIONS PERFORMANCE DATA: MODEL VOLTAGE DC/mA AClmA TERMINALS ! ......... lB:· K,G 24120 24V 20 19 C&l l 40 18,1 120V 20 C&H r~ 15.8 NOTE: Holding forctJS listed in above table corresponds with shaded values, non shaded values are slighty less, 1224 24V 85 81 C&L 75 l ,24120 t .. ,. 120V .100 C&L 110 HIGH HOLDING fORCEISPEClAL APPLICATIONS: 34.0 4St8 To obtain performance values in table above appfy high listed voUage to to·w voltage terminals {C & L). NOTE: This configuration can only be applied to modeis 1224 & 24120. ACCESSORIES Extensions: Surface Mounting: 6: tens.ion rods DHHBB (back box) -F ---.· .. · .. · .. ·. P -·· t " {~):: t ~~) 1 --~-r ~.-•·,,,,,,....,,. i: -:~.~";' <❖N• ............ ~, .. .,.,-., Magne:tk: Ooo.r Holde.r Extension Wrenches I i f nstallation Tools: OHOF ·(drm n1<turt:!.} ORDERING INFORMATION·: DH :F s :R G PC B 1 2 Door Holder Flush Mount Surface Mount Recessed Ground Mount Powdercoat Chrome Brass Plated Single CoH Double Coit NOTE; #2 indicates double coil ground mount model. Example: D!4 (24120) (S) {P) (C) {1) Door Holder I f . I Model/Voltage 1224r2412Q~24220 M9µ(lt S .... I~. Surtace~ Flush, Groufld, Rocessoo Finish Chrome, B.rassf' orm ,(Dark Bronze) Coils 1, 2 For ground mount models ACCESSO,Rl!ES: Extensions: l lnth extenSt.otl chrome 1 inch extension brass '15 inch extension chrome 1.5 irich eKten:sion brass 2 inch extenS!On chrome 2 inch extension brass 3 inch extension cn:rome 3 inch extension brass t OHE1PC DHElB OHE1,5PC DHE1 ,5:B DHE2PC DHE2B DHE3PC O.HE36 DHEAPC DHEAB 4 inch adjustabte extenSion chrome 4 inch actjusta:tite extension brass Hardware: DHSBPC DHSBB DHCPC OHCPB OHBB?C DHBBB DHW DHOF S\Nivef t)gse chrome. Sw,vet base brass Catch plate chrome Catch plate brass Surface back ho>: chrome Surf.ace back box brass Extension wrenches Drilling fixture LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING· BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7165-1477:0111 Page 1 of 2 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) MIRCOM TECHNOLOGIES, L TD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 7300 Fax (888) 660-4113 Email: mcherubin@mircom.com Models FX-2000, FX-2000H and FX-2000N (Flex-Net) analog fire alarm control units. Non-coded, automatic, manual, local, auxiliary, remote station, central station, mass notification, waterflow and sprinkler supervisory service. Refer to the listee's data sheet for detailed product description and operational considerations. System components: FX-2003-6, FX-2003-12, FX-2003S-12, FX-2003-6DS,FX-2003-12DS; Main Chassis/Power Supply FX-2017-12A, FX-2017S-12A, FX-2009-12, FX-2009S-12; Main Chassis/Power Supply FX-2003-12H, FX-2003-6H; Main Chassis/Power Supply FX-2003-12N, FX-2009-12N, FX-2017-12N, FX-2000ND, FX-2003-12NDS, FX-2009-12NDS, *FX-2003-12XTDS; Main Chassis/Power Supply FX-2003-12XT, FX-2000MNS, FX-2003-12NXTDS, FX-2017-12NDS; Main Chassis/Power Supply FX-2001-6K, FX-2001-6KU; One Analog Loop Fire Alarm Kits MD-596, MD-654, MD-871 , MD-871A, MD-770, MD-764, MD-757; Fire Alarm Module MD-597, DSPL-2440, DSPL-420, DSPL-420-16TZDS ; Display Module MD-519; Annunciator Assembly QBC-5000N; Battery Charger MD-616, IPS-2424,IPS-2424OS; Bypass Display DM-1008A, SGM-1004A, RM-1008A; Zone Adder Module PR-100, PR-300; Polarity Reversal/City Tie Module DACT-100, UDACT-300A; Dialer Module QX-5000; Voice Adder Module ECX-0012; Expander Chassis BBX..1024, -1072, -2000, BB-5008, -5014; Enclosure BBX-FXMNS, BBX-FXMNS (R), BBX-1024XT, BBX-1024XTR, BBX-1024OS(R): Enclosure RTl-1; Remote Trouble Indicator RAM-1032TZ, RAX-1048, RAX-1048TZ, *RAXN-LCD, RAXN-LCDG; Annunciator Module RAM-1032TZDS, RAM-1016TZDS, RAM-1016TZ, RAX-1048TZDS; Annunciator Module ALC-H16, -198S, -396S, -127H, -254H, ALCN-792M, ALCN-7920, *ALCN-792MISO, *ALCN-960M, *ALCN-960D: Loop Adder Module FDX-008, FDX-008KI; Fan, Damper Control Module *Rev . 12-04-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 INSTALLATION: MARKING: APPROVAL: NOTE: Listing No. 7165-1477:0111 FDG-008; Fan Damper Driver Module FDS-008; Selection Control Panel GEO-MIRCOM; Fan Damper Display QAZT-5302, QAZT-5302DS; Interface Modules ANC-5000; Audio Network Controller TNC-5000; Telephone Network Controller FNC-2000; Fire Network Controller QMP-5101N, QMP-5101NV; Paging Module QMT-5302N, QMT-5302NV; Master Telephone Module PS-2040; Node Power Supply QMB-S000N; Card Cage FOM-2000-SP; Fiber Optic Module UDACT-300A; Dialer Module FX-LOC, FX-LOC (R); Local Operating Console INX-10A, INX-10AC, INX-10ADS; Addressable NAC Booster Board & Chassis Open GN; Annunciator Software for FlexNet Page 2 of 2 In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as fire alarm control units for use with separately listed electrically and functionally compatible initiating and indicating devices. Suitable for high-rise applications when used with separately listed voice evacuation systems. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL Standard 864, 9th Edition. 1. For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Combined with 7170-1477: 119 *Rev. 12-04-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING· BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7120-1477:0107 7120 --ANNUNCIATORS Page 1 of 1 MIRCOM TECHNOLOGIES, L TD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin {888) 660-4655 Ext: 7300 Fax (888) 660-4113 Email: mcherubin@mircom.com Model RA-1000 remote multiplex annunciator panel. The main annunciator module provides indication for 32 zones. Each adder annunciator module provides indication for 48 additional zones. Unit includes main annunciator chassis RAM-1032 and adder annunciator chassis RAX-1048. Model RAX-LCD Liquid Crystal Annunicator, Model MGD-32 Master Graphic Driver chassis, Model MGDS-16/16 Main Display Annunicator Chassis and Model AGD-048 Adder graphic Driver chassis. Refer to listee's data sheet for additional detailed product description and operational considerations. 20-29 voe In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. For indoor use only. Listee's name, model number and UL label. Listed as annunciator panel for use with listee's separately listed compatible fire alarm control unit. Model RA-1000 is suitable for use with listed compatible Model FA-1000 (CSFM Listing No. 7165-1477:106) and FX-2000 (CSFM Listing No. (7165-1477:111) fire alarm control units. Model RAX-LCD is suitable for use with listed compatible Model FX-2000 fire alarm control unit (CSFM Listing No. (7165-1477: 111 ). •Rev. 11-04-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1645:0511 Page 1 of 1 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES ADEMCO INC.2 Corporate Center Drive, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@Honeywell.com Models HWF2A-COM and HWF2V-Com Commercial Internet and L TE Communicator. The unit uses the Internet as its primary reporting path, and switches to cell service (secondary path as backup) when the Internet is not available. *The units are transmitters that captures DACT communication from a host panel and converts to IP and/or Cellular for transmission to the receiving station. Units also have the option for IP Only or Cellular only without a backup path. Refer to listee's product specification data sheets and installation, operation, and maintenance manual for detailed product description and operational considerations. Primary -120 VAC, 60 Hz Secondary -18 VAC, 5 VA In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as a control unit accessory for use with separately listed compatible commercial fire alarm control units. Refer to listee's installation Instruction Manual for details. "'Rev 08-01-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING .. BUILDING MATERIALS L.ISTING PROGRAM LISTING SERVICE 7315-1335:0122 Page 1 of 1 7315 --POWER UNITS Altronix140 -58th Street, Bldg A-3W, Brooklyn, NY 11220 Contact: Gary Zatz (718) 567-8181 Fax (718) 567-9056 Email: garyz@altronix.com Model FireSwitch108 NAC Power Extender designed to provide expanded power capability for up to 8 notification appliance circuits. Refer to listee's data sheet for additional detailed product description and operational considerations. 120 V, 60 Hz, 4.8 A In accordance with listee's printed installation instructions. applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name. model number, electrical rating, and UL label. Listed as power supply unit for use with separately listed compatible fire alarm control units for indoor use only. Refer to listee's Installation Instruction Manual for details. 01-30-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, ME, F.P. E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7272-1477:0161 7272 --SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC Page 1 of 1 MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 7300 Fax (888) 660-4113 Email: mcherubin@mircom.com Models MIX-2251AP, MIX-2251TAP and MIX-2251TMAP photoelectric smoke detectors. Models MIX-2251TAP and MIX-2251TMAP employs an integral supplementary heat sensor. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as photoelectric smoke detectors when used in conjunction with listee's listed separately listed compatible fire alarm control units and bases. Each model is suitable for both open area protection and installations inside air ducts with air velocities up to 4000 feet per minute. 07-09-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT'OF FORESTRY & FIRE PROTECTION OFFICE OF THE ST A TE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7270-1477:0160 7270 --HEAT DETECTOR Page 1 of 1 MIRCOM TECHNOLOGIES, L TD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 7300 Fax (888) 660-4113 Email: mcherubin@mircom.com Models MIX-5251AP, -5251 HAP (fixed temperature) and MIX-5251 RAP (fixed temperature with rate-of-rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational_ considerations. MIX-5251AP = 1350 F fixed temperature MIX-5251RAP = 1350 F fixed temperature, 150 F per minute rate-of-rise MIX-5251 HAP= 1900 F fixed temperature In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the ~·uthority having jurisdiction. Listee's name, model number, electrical ratings, and UL Label. Listed as heat detectors for use with Models B210LP, B224BI, B224RB, B501, B501B, B501 BH, B501BH-2, B501 BHT, B501 BHT-2 and B200SR bases and separately listed compatible fire alarm control units. The base/head combination is for use with a listed, compatible, control panel, model FX-350 or FX-200. Refer to listee's Installation Instructions Manual for details. 07-09-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-14 77:0145 Page 1 of 1 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES MIRCOM TECHNOLOGIES, L TD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 7300 Fax (888) 660-4113 Email: mcherubin@mircom.com Models MIX-2000, -2001 , and -2001 R detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as smoke detector bases for use with listee's separately listed compatible smoke detectors. Refer to listee's Installation Instruction Manual for details. 7300-1394:0114 04-06-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1477:0167 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Page 1 of 1 MIRCOM TECHNOLOGIES, L TD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 7300 Fax {888) 660-4113 Email: mcherubin@mircom.com Model MIX-M501 MAP mini monitor module, Models MIX-M500RAP relay module, MIX-M502MAP interface module, MIX-M500SAP control module and MIX-500MAP monitor module. Refer to the listee's data sheet for detailed product description and operational considerations. 15-32 Vdc In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as fire alarm control unit accessory modules for use with separately listed compatible control units. Refer to listee's Installation Instructions Manual for details. 11-13-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P. E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ~ 7135-1653:0503 Page 1 of 2 7135 --AUDIBLE DEVICES System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com System Sensor Indoor 2-wire and *4-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-82, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR-2 and *TR-2W CeilingTrim Rings: *TRC-2 and *TRC-2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21 -2017 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria . Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, ME, F.P.E. Fire Engineering Division Listing Expires June 30, 2021 RATING: INSTALLATION: MARKING: APPROVAL: SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Listing No. 7135-1653:0503 Page 2 of 2 Refer to listee's data sheet for detailed product description and operational considerations. 12 voe regulated and 24 VDC/FWR In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7135-1653:0516 7135 --AUDIBLE DEVICES Page 1 of 1 System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com Models HRL-LF, HWL-LF, HCRL-LF, HCWL-LF, HGRL-LF and HGWL-LF are low frequency horns. Horn models HRL-LF, HWL-LF, HGRL-LF and HGWL-LF may be mounted on the wall and are intended for indoor use only unless otherwise indicated. Horn models HCRL-LF, HCWL-LF may be mounted on the ceiling and are intended for indoor use only unless otherwise indicated. The standard horn models are the HRL-LF, HCRL-LF (red enclosure) and HWL-LF, HCWL-LF (white enclosure). The horn has an 8 position selectable tone settings. Models HGRL-LF and HGWL-LF perform the same as HRL-LF/HWL-LF and use a "compact" housing which is intended to mount to a single gang electrical box. Refer to listee's printed data sheet for additional detailed product description and operational considerations The models HRL-LF, HW-LF, HCRL-LF, HRWL-LF, HGRL-LF and HGWL-LF are rated 16-33 VdcNFVVR (REGULA TED 24 DC/FWR). In accordance with the listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, audibility ratings and UL label Listed as audible devices when used with separately listed compatible fire alarm control units. For indoor dry use. Operating Temperature Range: 0°C to 49°C (32°F to 120°F). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P. E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ~ 7125-1653:0504 Page 1 of 2 7125 --FIRE ALARM DEVICES FOR THE HEARING IMPAIRED System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria . Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 RATING: INSTALLATION: MARKING: APPROVAL: Listing No. 7125•1653:0504 Page 2 of 2 Regulated 12 voe setting: 8-17.5 voe Regulated 24 VOC/fwr setting: 16-33 voe In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048•001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. ""Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria . Refer to listee's data sheet , installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P. E. Fire Engineering Division Listing Expires June 30, 2021 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 3550-1039:0100 Page 1 of 1 3550 --DOOR CLOSER/HOLDERS/RELEASING DEVICES RSG2700 Junipero Ave., Signal Hill, CA 90755 Contact: Helen Moyer (562) 630-4684 Fax (562) 529-5100 Email: helen@rsgsecurity.com Models DH-12, -24, -120, -1224, -24120, and -24220 door closer/holders. Refer to listee's data sheet for additional detailed product description and operational considerations. 12V, 24V, 120V, and 220V In accordance with listee's printed installation instructions and applicable codes and ordinances. The system is intended to be mounted in a horizontal position only. Listee's name, model number, rating and UL label. Listed as door closer/holders for use with separately listed compatible detectors and fire alarm control units. *Rev. 06-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used ta verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2020 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 . . . DOCUMENTATION -ff'C-2..o2o-CO~ 72-39 SYSTEM RECORD OF COMPLETION This form Is to be completed by the system Installation contractor st the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. : 1 Insert NIA In all unused /Ines. Attach additional sheets, data, or cslculatlons as necessary to provide a complete record. Form Completion Date: ______ _ Supplemental Pages Attached: ___ _ Name of property representative: _______________________ ......,... ____ _ Address: ____________________________________ _ Phone: ________ _ Fax: _________ _ E-mail: ___________ _ 2. INSTALLATION, SERVICE, TESTING, AND MONITORING INFORMATI N lnstalla ( Addres \I\., L,J tU-- Phone: ~"'--=-~~~..L--_..=...:~-.::11e&....::..l---1.,.J~~~__,J...:::;..-=..~ Service organization: ) CA...,""-' -e, t\\o l) \i &: Address: ____________________________________ _ Phone: __________ Fax: _________ _ Testing organization: :, (! ~ e✓ C&~ ~ ~ 0 ~ e · E-mail: ___________ _ Address: ____________________________________ _ E-mail: ___________ _ 3. DOCUMENTATION On-site location of the required record documents and site-specific software: _{ ... · ..... tl\.___G ____ ·_~-~-0___,;;;Da...v--__ .. ____ _ 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: )( New system a Modification to existing system NFPA 72 edition: 1.,,0 \ (e 4.1 Control Unit . Manufacturer: V\_~v< GDVVL 4.2 Software and Firmware Permit number: _____________ _ Model number: :f 'A ---ioo :o-\ ~'!>S Firmware revision number: ______________________________ _ 4.3 Alarm Verification '){ This system does not incorporate alarm verification. Number of devices subject to alarm verification: _ _._N__.._l _,_I\__ Alarm verification set for ___ seconds © 2015 National Fire Protection Association NFPA 72 (p. 1 of 3) ?lGURE 7 .8.2(a) System Record of Completion. (SIG-FUN) 2016 Edition ., ' ' ! 72-40 NATIONAL FIRE ALARM AND SIGNALING CODE SYSTEM RECORO· OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power 4 . \ (\ · Input voltage of control panel:_· ...:.),-;_;__'1,-0_~_\J---=.....,.;..U_· _______ _ Overcurrent protection: Type: _v~· _\..:..(.:...·.:::0:;__;:V::......;;l_~..:..--~......i..;~X:....::~:.::;....;:;;...__;iV:..__« __ _ Branch circuit disconnecting means location: __________ _ 5.1.2 Secondary Power ~ . Control panel amps: _____ _ Amps: L--0 Number: _________ _ Type of secondary power: \Ju..-:\\ e.,(' lj · Location, if remote from the plant: _ _..JfJi...=-..:...1..:."-.....:...------------------------ Calculated capacity of seconda~ \>ower to drive ~he system: / In standby mode (hours): (}; ""\ ~ D \) \f 5 In alarm mode (minute~): ___,;;;,;;...._._\r'-_\....;-A-_....;~=-)-:\~e ......... s"'---- 5.2 Control Unit Cl This system does not have power extender panels }(Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Dual Media Pathway Type Pathway Signaling Line Device Power Initiating Device Notification Appliance Other (specify): 7. REMOTE ANNUNCIATORS Type 8. INITIATING DEVICES Addressable or Type Quantity Conventional Manual Pull Stations Smoke Detectors Duct Smoke Detectors Separate Pathway Class )'-~ Y-'\2J Location Alarin or Supervisory v-- ~ Heat Detectors ~~C\..\Q\~ "\ o-( \;"'- Gas Detectors Waterflow Switches i..o Tamper Switches ~to C 2015 National Fire Protection Association FIGURE 7.8.2(a) Continued 2016 Edition Survivability Level ~ 1..--, Sensing Technology NFPA 72 (p. 2 of 3) ·, '· DOCUMENTATION 72-41 SYSTEM -RECORD OF COMPLETION (continued) ; 9. NOTIFICATION APPLIANCES Type Quantity Description Audible ·1,"~ \;ow ·~< ~al 1 2-A\CA S{)U ~ et Visible f,\ S\:x o \o-e.~ ~ ...,I Combination Audible and Visible S\.,\ \--\ b ( V\, $ \: ~ D \J t:/1 · 10. SYSTEM CONTROL FUNCTIONS Type Hold-Open Door Releasing Devices HVAC Shutdown Fire/Smoke Dampers Door Unlocking Elevator Recall Elevator Shunt Trip 11. INTERCONNECTED SYSTEMS ){ This system does not have intercoru:iected systems. a Interconnected systems are listed on supplementary sheet ___ _ 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor Quantity (~ i\ ~-t\P Af 0-.\06 1..., '~ \ P ..>. br .. Jr O ( S This system as specified herein has been installed according to all NFPA standards cited herein. Signed:______________ Printed name: _______ _ Organization: "'v----(,J)V'--~ \ ~\: ( o V'-lC...S Title: _________ _ Date: ______ _ Phone: _____ _ 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed:______________ Printed name: _______ _ Date: ______ _ Organization: ~V\.-(.,OV-X:, \ e...u\: ( OV\-\L 'J Title: _________ _ Phone: _____ _ 12.3 · Acceptance Test Date and time of acceptance test: ____________________________ _ Installing contractor representative: ___________________________ _ Testing contractor representative: ____________________________ _ Property representative: _______________________________ _ AHJ representative: _________________________________ _ © 2015 National Fire Protection Association NFPA 72 (p. 3 of 3) GURE 7.8.2(a) Continued 2016 Editton • 4 .. " 72-48 NATIONAL FIRE ALARM AND SIGNALING CODE NOTIFICATION APP~IANCE_ POWER PANEL SUPPLEMENTA.RY··RECORD OF COMPLETION This form Is a supplement to the System Record of Completion. It Includes a list of types and locations of notification appliance power extender panels. This form Is to be completed by the system Installation contractor at the time of system acceptance and approval. It shalf be permitted to modify this form ss needed to provide a more complete and(or c/~ar record. Insert NIA In all unused lines. Form Completion Date: _____ _ Number of Supplemental Pages Attached: ___ _ .?~ NOTIFICATION APPLIANCE POWER EXTENDER PANELS Make and Model Location Area Served Power Source \ \ t o \I\\ C ~ ·- ' , '< () _ £.,w ~ ~ c.h_ \n9' \ t; 1 :,:- , -s :: l, ;--. 9:-' Hf>CA-:\=t"?-~ ... I ' If Pt-\ -ff" .3 \o-'\ I Hf>c1 .:ff-ij)- \\~ V I-Pf ~E: L-lpvfJr S£ ¼J\J'"'~lA H·Fc, •c.o J See Main System Record of Completion for additional Information, certifications, and approvals. @ 2015 National Fire Protection Association FIGURE 7.8.2(d) Notification_Appliance Power Panel Supplementary Record of Completion. (SIG-FUN) 2016 Edition I . ';I . . I NFPA 72