HomeMy WebLinkAboutPD 2019-0032; GOERTZEN RESIDENCE; GEOTECHNICAL RESPONSE TO THIRD PARTY 3RD REVIEW; 2020-03-25, ... fllffl!U'--~ ------------------------------ March 25, 2020 Greg Goertzen 3466 Camino Michelle Carlsbad, California 92009 SUBJECT: File No. 1127H6-19 SITE INSPECTION Dear Mr. Goertzen: Response to Third Party Geotechnical Review Proposed Residential Building Site El Fuerte Street and Acuna Court City of Carlsbad In response to the third party review by Hetherington Engineering, dated March 6, 2020. P.O. Box 1195 Lakeside, California 92040 (619) 443-0060 1. The consultant should specify the sulfate exposure category (ACI 318) based on soluble sulfate testing and provide recommendations for sulfate resistant concrete if necessary. The structural engineer should design all concrete flatwork and structural concrete to default to the severe sulfate exposure category (ACI 318) unless corrosion testing is provided. 2. The consultant should provide the site seismic design category. The Seismic Design Category is D based on the OSHPD Seismic Design Maps consistent with Section 1613.3.5 of the 2016 CBC and Section 11.6 of ASCR 7. 10. If we can be of any further assistance, please do not hesitate to contact our office. This opportunity to be of service is sincerely appreciated. Respectfully submitted, Chin C. Chen, RPE C34442 CCC/mlj o. C03444 q,30· ·-