Loading...
HomeMy WebLinkAbout5909 SEA OTTER PL; 200; FPC2021-0199; PermitPERMIT REPORT Fire Permit Print Date: 12/27/2021 Job Address: 5909 SEA OTTER PL, # 200, CARLSBAD, CA 92010-6675 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel#: 2090820900 Track#: Valuation: $333,430.19 Lot#: Occupancy Group: Project#: #of Dwelling Units: Plan#: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Project Title: Description: AIRSPACE TECHNOLOGIES -2ND FLR FIRE ALARM Tl (24 DEVICES, ADDRESSABLE) FEE FIRE Tl Fire Alarm System Total Fees: $682.00 Total Payments To Date: $682.00 Fire Department (city of Carlsbad Permit No: FPC2021-0199 Status: Closed -Finaled Applied: 10/20/2021 Issued: 12/10/2021 Fina led Close Out: 12/27/2021 Inspector: Final Inspection: FPContractor: ADT COMMERCIAL JOHN STASUKEVICH 10107 CARROLL CANYON RD SAN DIEGO, CA 92131-1109-SAN DIEGO (760) 535-0045 Balance Due: AMOUNT $682.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov Af'JT- commercia1 Equipment Specifications Fire Alarm System Modification FOR AIRSPACE TECHNOLOGIES PHASE 2, 2ND FLOOR 5909 SEA OTTER PLACE CARLSBAD, CA 92010 ADT Commercial IO I 07 Carroll Canyon Road San Diego, CA 92 13 I Phone (760) 233-9787 I Fax (760) 233-9788 C-10, C-16 I C-1065604 ~i:JWARDS EDWARDS'lll Catalog ► Intelligent Input-Output nited Technologies LI FE SAFETY[] INC IDENT MANAGEMENT Input Modules SIGA-CT1 , SIGA-CT1 HT, SIGA-CT2, SIGA-MCT2 Overview The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Tem- perature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). The actual function of these modules is determined by the "personal- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. The SIGA-CT1, SIGA-CT1 HT and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate 1/0 and data loop connections are made to each module. The SIGA-CT1 HT module operates at an expanded temperature range of 32 °F to 158 °F (0 °C to 70 °C) for those applications requiring more extreme environmental temperature variation. The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two-and six-module UIO mother- boards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Page 1 of4 ~MEA I @ @ 7300-1657: 0121 S3424 Standard Features • Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the mod- ule through the loop controller. • SIGA-CT1 HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. • Plug-in (UIO} or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. • Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. • Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. • Ground fault detection by address Detects ground faults right down to the device level. o ATA s HEE r E85001-0241 Not to be used for installation purposes. Issue 1 Signature Series Overview The Signature Series intelligent analog-addressable system from EDWARDS Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly mainte- nance and service tools. Analog information from equipment con- nected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device pro- vides four additional benefits -Self-diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self-diagnostics and History Log -Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. Automatic Device Mapping -The Signature Data Control- ler (SOC) learns where each device's serial number address is installed relative to other devices on the circuit. The SOC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. Installation SIGA-CT1, SIGA-CT1 HT and SIGA-CT2: modules mount to North American 2½ inch(64 mm) deep 1 -gang boxes and 1 ½ inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates. The terminals are suited for #12 to #18 AWG (2 .5 mm2 to 0. 75 mm2) wire size. Status LEDs LED viewing ports SIGA-MCT2: mount the UIO motherboard inside a suitable ED- WARDS enclosure with screws and washers provided. Plug the SIGA-MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. UIO Motherboard 1 6-32 Self-tapping Plug-in (UIO) Captive Module screws -Cabinet or electrical enclosure Electronic Addressing -The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two per- sonality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM -LATCHING (Personality Code 1) -Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM -DELAYED LATCHING (Person- ality Code 2) -Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE -NON-LATCHING (Personality Code 3) -Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE -LATCHING (Personality Code 4) -Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. ---------------------------:D:-:A-=T-:-A--::S:--:-H:-:E:-::-:E r E85001-0241 Page 2 of 4 Not to be used for installation purposes. Issue 1 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 µF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) 4,000 ft (1,219 m) #14 AWG (1 .50 mm2) #12 AWG (1.50 mm2) ffi && Style B (Class 8) -----< TB2 Typical N.O. Initiating Device • • UL/ULC Listed 471<.n EOL Red LED Green LED (Alarm/Active) ------ll+-.. © ~ ----------(Normal) { DATA IN(+) DATA IN(-) ">------------' From Signature Controller or Previous Device £ DATA OUT(+)} ----DATA OUT(-) To Next Device SIGA-CT1 , SIGA-CT1 HT NOTES & Maximum 25 Ohm resistance per wire. £. Maximum #12 AWG (2.5 mm2 ) wire; Minimum #18 AWG (0. 75 mm2). £. Refer to Signature controller installation sheet for wiring specifications . .,& Maximum 10 Vdc @ 350 µA &_ The SIGA-UIO6R and the SIGA-UIO2R do not come with TB14. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of EDWARDS's Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. Page 3 of 4 Typical N.O. Initiating Device INPUT l INPUT 2 oc 1 I ..-------i ~ UL/ULC Listed 471<.n EOL Red LED (Alarm/ Active) UL/ULC Listed 471<.n EOL ______ Green LED (Normal) { DATA IN(+) DATA IN(-),,_ ______ _. DATA OUT ( + )} ---DATA OUT(-) To Next Device From Signature Controller or Previous Device UL/ULCListed oci 47'rW/EOL & Detain+~ Signature ; Data 2 drcuit 1 + Data Out Green LED !Normal) Red LEDIActivel & SIGA-CT2 1 2 3 4 SIGA-MCT2 l ~UL/ULCListed ~ 47'rW/ EOL MCT2 UIO(R)seriesmotherboard No connections required for MCT2 Other modules moy require connections. o AT A s HEE T E85001-0241 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us ... Email: edwards. fire@fs. utc. com Web: edwards-fire.com 1016 Corporate Park Drive Mebane, NC 27302 EDWARDS is a registered mark in the United States and other countries. © 2018 United Technologies Corporation. All rights reserved. Page 4 of4 Specifications Catalog Number SIGA-CT1 HT I SIGA-CT1 SIGA-CT2 I SIGA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types 49 (factory set) Four sub-types (personality codes) are available (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250µA; Standby = 396µA; Activated = 400µA Activated = 680µA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 2½ inch (64 mm) deep one-gang box-UlO2R/6R/6 es and 1 ½ inch (38 mm) deep 4 inch square boxes Motherboard with one-gang covers and SIGA-MP mounting plates Operating Environment 32°F to 158°F I 32°F to 120°F (0°C to 49°C) (0°C to 70°C) Storage Environment -4°F to 140°F (-20°C to 60°C); Humidity: 0 to 93% RH LED Operation On-board Green LED -Flashes when polled; On-board Red LED - Flashes when in alarm/active. Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM Ordering Information Catalog Number SIGA-CT1 SIGA-CT1HT SIGA-CT2 SIGA-MCT2 Description Single Input Module -UUULC Listed Single Input Module High Temperature Operation UUULC Listed Dual Input Module -UUULC Listed Dual Input Plug-in (UIO) Module -UL, ULC Listed Related Equipment 27193-11 Surface Mount Box -Red, 1-gang 27193-16 Surface Mount Box -White, 1-gang SIGA-UIO2R Universal Input-Output Module Board w/Riser Inputs -Two Module Positions SIGA-UIO6R SIGA-UIO6 MFC-A SIGA-MB4 SIGA-MP1 SIGA-MP2 SIGA-MP2L Universal Input-Output Module Board w/Riser Inputs -Six Module Positions Universal Input-Output Module Board -Six Module Positions Multifunction Fire Cabinet -Red, supports Signature Module Mounting Plates Transponder Mounting Bracket (allows for mounting two , -gang modules in a 2-gang box) Signature Module Mounting Plate, 1 footprint Signature Module Mounting Plate, 1 /2 footprint Signature Module Mounting Plate, 1 /2 extended footprint Ship Wt. lbs {kg) 0.4 (0.15) 0.4 (0.15) 0.4 (0.15) 0.1 (0.05) 1.0 (0.6) 1.0 (0.6) 0.32 (0.15) 0.62 (0.28) 0.56 (0.25) 7.0 (3.1) 0.4 (0.15) 1.5 (0.70) 0.5 (0.23) 1.02 (0.46) o AT A s H E ET E85001 -0241 Not to be used for installation purposes. Issue 1 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7300-1657:0121 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Page 1 of 1 EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewel I Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda. m icochero@carrier.com Models SIGA-CC1, SIGA-CC2, SIGA-CT1, SIGA-CT1 HT, SIGA-CT2, SI GA-CR, SIGA-CRR, SIGA-UM, SIGA-MM1, SIGA-WTM, SIGA-IM, *SIGA-IM2, SIGA-MDM, SI GA-MAB, SIGA-MCT2, SIGA-MCC1, SIGA-MCC2, SIGA-MCR, and SIGA-MCRR Remote Transponders. Models SIGA-AA30 and SIGA-AA50 audio amplifiers. Models SIGA-APS and SIGA-APS-220 power supplies. Models SIGA-MB4, SIGA-MP1, SIGA-MP2 and SIGA-MP2L mounting plates. Models SIGA-UIO2R, SIGA-UIO6 and SIGA-UIO6R motherboards. Model CS-SIGA-CC1 P releasing module. Models SIGA-CC1 Sand SIGA-MCC1 S Auto-Sync Output Modules. Models MFC-A and MFC-AD Enclosures. Model SIGA-CR2 Control Relay Module. Model SIGA-CT1 HT Signature Series High Temperature Single Input Module. SI GA-CRH High Power Control Relay Module. Refer to listee's data sheet for additional detailed product description and operational consideration. 15.2 -19.95 voe In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Formerly 7300-1591:121 and 7300-1388:178 *Revision 10-30-20 VWN This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DA V/D CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 ~CIWARDS United Technologies EDWARDS'"' Catalog ► Strobes, Horns, Bells, Chimes L IFE SAFETY 9/" INCIDENT MANAGEMENT Genesis LED GC Series Ceiling Mount Notification Devices Overview 115 Genesis LED GC Series horns and LED strobes feature a sleek low profile design and energy-efficient technology that makes them less expensive to install and operate by reducing overhead. High performance LEDs require fewer power supplies, backup power, and batteries. These new appliances are designed with, energy-efficiency, and life safety in mind. Genesis LED GC Series uses high efficiency optics, combined with patented electronics, to deliver a highly controlled and efficiently focused light distribution pattern in exchange for lower current requirements. Strobes feature field-selectable 15, 30, 75, or 115 cd light output. Compared with Xenon-type strobes, Genesis LED GC Series appliances need fewer power supplies and often smaller wire gauge, which lightens conduit requirements. They are also backwards compatible with legacy strobes, so there's no need to replace all your existing devices to upgrade to new LED technology. In fact, GC strobes can be mixed on the same circuit and used in the same field of view as Xenon-based strobes. This makes Genesis LED GC Series ideal for new installations and retrofits alike. Field-configurable sound output levels provide the flexibility modern life safety projects demand, while the Genesis LED control protocol keeps multiple strobes on compatible NAC circuits synchronized to well within NFPA 72 requirements. Serviceability is another area where GC Series appliances shine. The universal room side wiring plate allows for pre-installation and electrical wiring as well as checking continuity with the included diagnostics check bar. GC Series devices can then be easily snapped into place with the confidence of knowing the wiring is correct. The innovative under-cover diagnostic test points provide easy access to device circuit testing while mounted. Page 1 of6 Standard Features • High Performance LED Strobe Technology -Ultra low device current consumption allows: -More devices per circuit -Ability to use lower gauge wire -Longer wire runs -Fewer booster power supplies -High efficiency optics -Selectable 15, 30, 75, or 115 cd light output c@us S218, S5389 Fe -~ -LED devices may be mixed with legacy Xenon strobes • Efficient Audible Output -Selectable high or low dB horn output -Selectable temporal or steady horn output -Improved audio frequency range for better wall penetration • Low-profile Design -Ultra-slim ... protrudes about 1.5" from the mounting surface -Attractive appearance ... no visible mounting screws • Multiple "FIRE" Marking Options -Order English, French, Spanish or no FIRE markings -Change markings at any time with replaceable quick-swap covers • Easy to Install -Pre-install and pre-wire with convenient universal room side wiring plate -Check electrical continuity on room side wiring plate with included diagnostics check bar -Diagnostics port streamlines device circuit testing -Fits 1-gang, 2-gang, 4-inch octagon, and 4-inch square electrical boxes -Optional red and white trim plates available -Slide switches for field configuration -12 to 18 AWG in-out screw terminals for quick wiring o AT A s H E ET E85001 -1 021 Not to be used for installation purposes. Issue 1 Application Strobes Genesis GC Series strobes are UL 1971-listed for use indoors as ceiling-mounted public-mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87 dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act. Synchronization is important in order to avoid triggering seizures in people with photosensitive epilepsy. All Genesis strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. See the specifications table for a list of compatible sources. Horns Genesis horn output reaches as high as 92 dBA and features an improved audio frequency range compared with other Genesis horns. This results in excellent sound penetration through walls and a clear warning of danger. Horn only models may be configured for either coded or non-coded notification appliance circuits. They can also be set for high or low dBA output. This setting reduces horn output by about 6 dBA. The suggested sound pressure level for each signaling zone used with alarm signals is at least 15 dBA above the average ambient sound level, or 5 dBA above the maximum sound level having a duration of at least 60 seconds, whichever is greater. These values are measured at five feet (1 .5 m) above the floor. The average ambient sound level is A-weighted, fast response sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dBA reduction of the received sound pressure level. The actual effect depends on the acoustic environment in the space. A 3 dBA difference represents a barely noticeable change in volume. Installation Genesis GC horns and strobes mount to the required GP1 O room side wiring plate. The GP10 mounting plate is ordered separately from the GC device in packs of 10 for convenient pre-installing and pre-wiring. The device can be removed easily from the room side wiring plate by pushing up with a screwdriver. The cover can also be removed from the device easily with a screwdriver to access the light and sound output settings and a diagnostics test port for voltage testing. Removing Cover Removing Device Page2of6 Genesis LED GC Series horns, strobes, and horn-strobes mount to any standard one-gang, two-gang, 4-inch octagon, and 4-inch square electrical box. Matching optional GCT trim rings are available to cover oversized openings. Optional color matched double-gang surface boxes are also available. Genesis LED GC series are listed to be both wall mounted or ceiling mounted. (1) Electrical Box (2) Trim Plate (optional) (3) Wiring plate (required, ordered separately) (4) Machine screw (2X, supplied with wiring plate) (5) GC signaling appliance Wiring 0 0 @@@~ Horn/strobe + >----=---=---. + Horn/strobe circuit in I (signal polarity ->----=---"'11!:!~,i-;iili+-iiJl-;iili+-iiJl"°i;,---"jj_ _!]J _[i _i] _[i _~u; _,,~~-.,,,----circuit out shown in the active condition) o AT A s H E ET E85001 -1 021 Not to be used for installation purposes. Issue 1 Dimensions GC Notification Appliances 1.82" (4.62 cm) GCT Trim Plate (optional) 0.3" (0.76 cm) Diagnostics Test points indicated above are used to validate the Notification Appliance Circuit and verify device function. Page 3of6 0 Field Configuration Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. By sliding the tone selector switch, horn only models may be configured for constant horn output that can be coded at precise inteNals by EDWARDS control panels and control modules. Note: Temporal 3 coding is the required output for fire notification devices per NFPA 72. Any device coding other than temporal 3 is at the discretion and approval of the local authority having jurisdiction (AHJ). Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by sliding the tone selector switch. This reduces the output by about 6 dBA. Genesis LED clear strobes and horn-strobes may be set for 15, 30, 75, or 115 candela output. The output setting is changed by simply removing the cover and sliding the candela switch to the desired setting. The device does not have to be removed from the wall to change the output setting. The setting remains visible through a small window on the device after the cover is closed. Light and Sound Output Settings (1) Constant, low dB (2) Constant, high dB (3) T3 temporal, low dB (4) T3 temporal, high dB (5) 115 candela (6) 75 candela (7) 30 candela (8) 15 candela Operating current Horns Sound 16to 33 16 to 33 setting VDC VFWR C-Low, 20mA 25mA T-Low C-High, 30mA 40mA T-High Horn-Strobes Strobe setting 15, 30, 75,115 Sound setting C-Low, T-Low C-High, T-High --=----(1) ---=-'-=-' -(2) --'-'--=-' -(3) __;\;..;.../_(4) Strobes Strobe setting 15, 30, 75, 115 16to 33 VDC 50mA 60mA (5) (6) (7) (8) 16 to 33 16 to 33 VDC VFWR 35mA 45mA 16 to 33 VFWR 60mA 75mA o AT A s H E ET E85001 -1 021 Not to be used for installation purposes. Issue 1 Sound Output Horn & Horn-Strobe Sound setting C-Low, T-Low C-High, T-High Reverberant {UL464) 80dBA 86dBA Anechoic (CAN/ULC -5925) 86dBA 92dBA Sound pattern -Horn Models (ULC) Axis Angle (0) Output (dBA} Horizontal 115 and 55 93.3 Vertical 125 and 50 91.7 Sound pattern -Horn-Strobe Models (ULC) Axis Angle (0) Output (dBA) Horizontal 145 and 35 93.0 155 and 35 90.8 Vertical 135 and 35 92.0 155 and 25 85.4 Specifications Operating voltage 16 to 33 voe, 16 to 33 VFWR Horn signal type Constant or TC3 temporal Light output 15, 30, 75, or 115 candela Strobe flash rate 1 fps (flash per second) approx. Light Distribution Horizontal Left 80 85 90 85 80 Measured ---UL Minumum 5 O 5 Synchronization 20 O max. between any two devices. To determine allowed wire resistance, refer to these specifications, and the specifications for the synchronized signal source. Synchronization Sources Wire size Mounting Dimensions (0 x D) Strobe-to-box center offset Compatible electrical boxes [1] Trim plates Operating environment Temperature Relative humidity Storage Temperature Edwards CC Series Signal Modules, Booster and Auxiliary Power Supplies, Intelligent and Conventional Control Panels 12 to 18 AWG (0.75 to 2.50 mm2) Wall or Ceiling mount 6.8 x 1.82 in. (17.27 x 4.62 cm) -1 . 70 inches (-4.32 cm) 1-gang, 2-gang, 4-inch octagon, 4-inch square GCTR, GCTW 10.6 x 0.3 in. (26.92 x 0.76 cm) 32 to 122°F (0 to 50°C) 0 to 93% noncondensing -40 to 158 F (-40 to 70 C) [1] Electrical boxes must be at least 1-1/2 in. (3.81 cm) deep. Horizontal Right 75 80 85 90 85 80 Vertical Bottom Page 4 of 6 o AT A s HEE T E85001-1021 Not to be used for installation purposes. Issue 1 Ordering Information Notification Appliances Color Marking GCARF Red FIRE GCARF-FR Red FEU GCARF-SP Red FUEGO GCARN Red None GCAWF White FIRE GCAWF-FR White FEU GCAWF-SP White FUEGO GCAWN White None GCVRF Red FIRE GCVRF-FR Red FEU GCVRF-SP Red FUEGO GCVRN Red None GCVWF White FIRE GCVWF-FR White FEU GCVWF-SP White FUEGO GCVWN White None GCAVRF Red FIRE GCAVRF-FR Red FEU GCAVRF-SP Red FUEGO GCAVRN Red None GCAVWF White FIRE GCAVWF-FR White FEU GCAVWF-SP White FUEGO GCAVWN White None Accessories O GCTR Room Side Wiring GP10 Plate (required, ordered separately) Model Number Syntax, Appliances lGen~~s= s;;:~:g mount appliances I Housing Color R = Red W =White GCAVRF----Housing Marking L N =None F-FR = FEU F-SP = FUEGO Functions F = FIRE A = Horn only A = ALERT* V = Strobe only AV = Horn-Strobe Page 5 of6 27193-21 * ALERT Marking available on white strobe model only. See replacement covers for more options. Replacement Appliance Covers Color Marking GCARA-CVR Red ALERT GCARF-CVR Red FIRE GCARF-FR-CVR Red FEU GCARF-SP-CVR Red FUEGO GCARN-CVR Red None GCAWA-CVR White ALERT GCAWF-CVR White FIRE GCAWF-FR-CVR White FEU GCAWF-SP-CVR White FUEGO GCAWN-CVR White None GCVRA-CVR Red ALERT GCVRF-CVR Red FIRE GCVRF-FR-CVR Red FEU GCVRF-SP-CVR Red FUEGO GCVRN-CVR Red None GCVWA-CVR White ALERT Strobe GCVWF-CVR White FIRE Covers GCVWF-FR-CVR White FEU GCVWF-SP-CVR White FUEGO GCVWN-CVR White None GCAVRA-CVR Red ALERT GCAVRF-CVR Red FIRE "'," GCAVRF-FR-CVR Red FEU ii1iimil!i GCAVRF-SP-CVR Red FUEGO GCAVRN-CVR Red None o!.,..., GCAVWA-CVR White ALERT Horn-strobe GCAVWF-CVR White FIRE Covers GCAVWF-FR-CVR White FEU GCAVWF-SP-CVR White FUEGO GCAVWN-CVR White None Trim plate, GC Series, GCTW Trim plate, GC Series, red white Two-gang surface 27193-26 Two-gang surface mount box, red mount box, white Model Number Syntax, Replacement Covers lGen~~s= s;;:~:g mount appliances I Housing Color R = Red W =White Cover GCAVRF-CVR---Designation T ------Cover Marking L N =None Functions F-FR = FEU A = Horn only F-SP = FUEGO V = Strobe only F = FIRE AV = Horn-Strobe A = ALERT o AT A s H E E T E85001 -1 021 Not to be used for installation purposes. Issue 1 LIFE SAFETY & INCIDENT MANAGEMENT Contact us ... Email: Web: edwards. fire@fs. utc. com edwards-fire.com 8985 Town Center Pkwy. Bradenton, FL 34202 EDWARDS is a registered mark in the United States and other countries. © 2019 United Technologies Corporation. All rights reserved. Page 6 of 6 o AT A s H e e T E85001 -1 021 Not to be used for installation purposes. Issue 1 0 (0 0 ~ (0 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-1657:0510 7125 --FIRE ALARM DEVICES FOR THE HEARING IMPAIRED Page 1 of 2 EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda. m icochero@carrier.com Edwards Models GCV, GCVWF, GCVWF-SP, GCVRF-SP, GCVWF-FR, GCVRF-FR, GCVRF, GCVWN, GCVRN, *GCV*, *GCV*F, *GCV*F-FR, *GCV*F-SP, and *GCF*N indoor wall/ceiling mounted strobes. Edwards Models GCVWA and *GCV*A indoor wall mounted strobes. Kidde Models EGCV, EGCVWF, EGCVRF, EGCVRN, EGCVWN, *EGCV*, *EGCV*F, and *EGCV*N indoor wall/ceiling mounted strobes. *For models with an Asterisk"*": The* can be any 3 digit alphanumeric or all numeric characters used to designate custom cover color option other than red or white. The basic differences between each model are as follows: -GCV base model for strobe -Suffix WF white enclosure with FIRE marking -Suffix RF red enclosure with FIRE marking -Suffix WN white enclosure with no marking -Suffix RN red enclosure with no marking -Suffix FR marking is FEU -Suffix SP marking is FUEGO -Suffix WA white enclosure with ALERT marking -Prefix E designates brand as KIDDE instead of EDWARDS Refer to listee's data sheet for additional detailed product description and operational considerations. 16-33 Vdc/fvvr Candela 15cd, 30cd, 75cd, 115cd selectable In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Models beginning with G are marked Edwards. *Revision 05-12-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 APPROVAL: Listing No. 7125-1657:0510 Page 2 of 2 Models beginning with E are marked Kidde. Listed as a strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. The lights are only considered synchronized when used in conjunction with Listed Model G1 M-RM (CSFM listing No. 7300-1657:0201) or Model SIGA-CC1S (CSFM listing No. 7300-1657:0121). Refer to listee's Installation Instruction Manual for details. *Revision 05-12-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-1657:0515 7125 --FIRE ALARM DEVICES FOR THE HEARING IMPAIRED Page 1 of 2 EDWARDS, A Division of UTC Fire & Security Americas Corporation, lnc.8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Conover (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@carrier.com Edwards Models GCA, GCARF, GCARF-FR, GCARF-SP, GCARN, GCAWF, GCAWF-FR, GCAWF-SP, GCAWN, *GCA*, *GCA*F, *GCA*F-SP, *GCA*F-FR, and *GCA*N Synchronizable Wall/Ceiling Mounted Horns for indoor use. KIDDE Models EGCA, EGCARF, EGCAWF, *EGCA*, and *EGCA*F Synchronizable Wall/Ceiling Mounted Horns for indoor use. Edwards Models GCAV, GCAVRF, GCAVRF-FR, GCAVRF-SP, GCAVRN, GCAVWF, GCAVWF-FR, GCAVWF-SP, GCAVWN, *GCAV*, *GCAV*F, *GCAV*F-SP, *GCAV*F-FR, and *GCAV*N Wall/Ceiling Mounted Horn/Strobes for indoor use. KIDDE Models EGCAV, EGCAVRF, EGCAVRN. EGCAVWF, EGCAVWN, *EGCAV*, *EGCAV*F, and *EGCAV*N Wall/Ceiling Mounted Hom/Strobes for indoor use. Edwards Models GCTR, *GCT*, and GCTW Trim Plates. KIDDE Models EGCTR, *EGCT*, and EGCTW Trim Plates. Model GP maybe followed by a numeric value to designate the quantity per package Room Side Wiring Plate. *For models with an Asterisk"*": The* can be any 3 digit alphanumeric or all numeric characters used to designate custom cover color option other than red or white. Refer to listee's data sheet for additional detailed product description and operational considerations. 16-33 Vdc/fwr Candela 15 ed. 30cd, 75, 115 cd selectable 82 dB at 10 feet In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. *Revision 05-12-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 MARKING: Listee's name, model number, electrical rating, and UL label. Models beginning with G are marked Edwards. Models beginning with E are marked for Kidde. Listing No. 7125-1657:0515 Page 2 of 2 APPROVAL: Listed as horn or horn/strobe when used with a separately listed compatible fire alarm control unit. Units are suitable for indoor dry locations only. These units can generate a distinctive 3-Pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72. Listed as a strobe or horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. The lights are only considered synchronized when used in conjunction with Listed Model G1 M-RM (CSFM listing No. 7300-1657:0201) or Model SIGA-CC1S (CSFM listing No. 7300-1657:0121). Refer to listee's Installation Instruction Manual for details. *Revision 05-12-20 VWW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022