Loading...
HomeMy WebLinkAbout5909 SEA OTTER PL; 200; FPC2021-0187; PermitPERMIT REPORT Fire Permit Print Date: 12/27/2021 Job Address: 5909 SEA OTTER PL, # 200, CARLSBAD, CA 92010-6675 Permit Type: FIRE-Construction Commercial Work Class: Parcel#: 2090820900 Track #: Valuation: $333,430.19 Lot#: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Description: AIRSPACE TECHNOLOGIES PHASE 2 -SPRINKLER Tl (41 HEADS) Applicant: TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 (760) 295-3436 FEE FIRE NFPA 13 or 13R System 7-100 heads Fire Sprinklers Total Fees: $607.00 Total Payments To Date: $607.00 Fire Department {city of Carlsbad Permit No: FPC2021-0187 Status: Closed -Finaled Applied: 10/05/2021 Issued: 10/15/2021 Fina led Close Out: 12/27/2021 Inspector: Final Inspection: FPContractor: TITAN FIRE PROTECTION INC 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 (760) 295-3436 Balance Due: AMOUNT $607.00 $0.00 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov Fire Protection Contractor -License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS Airspace Technologies Phase 2 5909 Sea Otter Place, Suite 200 Carlsbad, CA 92010 Page 1 of 6 TECHNICAL DATA MICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VK100 {K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Micromatic® Standard Response Upright VK100 Sprinkler is a small, ther- mosensitive, glass-bulb spray sprinkler available in several different finishes and tem- perature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions. 2. LISTINGS AND APPROVALS c@us cULus Listed: Category VNIV <8> FM Approved: Classes 2001 , 2002, 2015, 2017, 2043 NOTE: Other International approval certificates are available upon request. Ii\ WARNING: Cancer and Reproductive Harm-I ~ www.P65Warnings.ca.gov I Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)t Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/8" (60 mm) t cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). ** Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring -Exposed, Screw and Pipcap -ENT plated. ttNot for FM Approval. Ordering Information: (Also refer to the current Viking price list.) Order Micromatic® Standard Response Upright VK100 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, Wax Coated = C, Wax Over Polyester = V-/W, ENT= JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 212 °F (100 °C) = M, 286 °F (141 °C) = G, 360 °F (182 °C) = H, 500 °F (260 °C) = L. For example, sprinkler VK100 with a 1/2" thread, Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12986AB Available Finishes And Temperature Ratings: Refer to Table 1. Form No. F _052014 19.10.14 Rev 19.1 Replaces Form No. F _052014 Rev 17.1.P65 (Added ENT; updated FM language.) Page 2 of 6 TECHNICAL DATA MICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VK100 {KS.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017). B. Standard Wrench for Wax Coated Sprinklers: Part No. 10896W/B (available since 2000) C. Socket Wrench for Wax Coated Sprinklers: Part No. 13577W/B* (available since 2006) *A½" ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Micromatic® Standard Response Upright Sprinkler VK100 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Standard Sprinkler Wrench 21475M/B Form No. F _052014 19.10.14 Rev 19.1 Protective Sprinkler Cap ------- Figure 1: Standard Sprinkler Wrench for Wax Coated Sprinklers 10896W/B Standard Sprinkler Wrenches "IKINCG ® TECHNICAL DATA Page 3 of 6 MICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VK100 {KS.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Li)·.~·.. ·•_;"'.::·-~:-.<-', .. ~--~·~·-~~~/K~~:,: -'~. -~--::,.;-: ... , ~~f~.i~~,-f,, :" ,_ ::_\.)?:,_:.:~~--~·//:~::-{i;~ ,, -~;/ .. _-:~'/ .. ~.,_·:~:.:_j~_ ~:;}-J) t\rl~\: -:~_;. :·/-: :~r;] ra~~1fat~ 1~,.j~~.i.~~•1\1 i~~~~ ~;l1[~""':~"',\~~~-ii~~~~,.i~t:~~~ t~ll1~i~~~~~--\1M~'@.l~~~-~~~t"~ltlii~-;;~ii,~-\~ Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Extra High 360 °F (182 °C) 300 °F (149 °C) Mauve Ultra High3 500 °F (260 °C) 465 °F (240 °C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black PTFE in all temperature ratings. ENT in all temperature ratings except 135 °F (57 °C). Wax-Coated Brass and Wax over Polyester5 for sprinklers with the following temperature ratings: 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 286 °F (141 °C) Dk. Brown Wax5 Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), response time may be severely retarded. 4 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. 5 Wax melting point is 170 °F (76 °C) for 286 °F (141 °C) temperature rated sprinklers. FormNo.F_052014 19.10.14 Rev19.1 Page 4 of 6 TECHNICAL DATA MICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VK100 (KS.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Base Part SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to UL Design Criteria.) Number1 NPT BSP U.S. metric2 Inches mm cULus4 VdS LPCB Standard Orifice 12986 80.6 2-1/4" 57 A1,B3,C4,D2, ES Approved Temperature Ratings A -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 360 °F (182 Approved Finishes °C) 1 -Brass, Chrome, White Polyester5·6, and Black Polyester5·6 B -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 2 -Brass and Chrome and 200 °F (93 °C) 3 -Wax-Coated Brass and Wax Over Polyester5 CE C-286°F(141 °C) 4 -High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient tem- 0 -500 °F (260 °C)7 perature allowed at ceiling = 150 °F (65 °C) E -155 °F (68 °C), 175 °F (79 °C), 200 °F (93 5 -ENT5 °C), 286 °F (141 °C), 360 °F (182 °C), and 500 °F (260 °C)7 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cU Lus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. cULus Listing Requirements; The Viking Micromatic® Standard Response Upright Sprinkler VK100 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light, Ordinary, and Extra Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Bulletin Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F _052014 19.10.14 Rev 19.1 \IIKll'ICG ® TECHNICAL DATA Page 5 of 6 MICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VK100 {K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com SIN NPT BSP 12986 VK100 1/2" 15 mm 10138 VK100 1/2" 15 mm 10193 VK100 15 mm Approved Temperature Ratings A -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 212 °F (100 °C), 286 °F (141 °C), and 360 °F (182 °C) B -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) and 212 °F (100 °C) C -286 °F (141 °C) D -500 °F (260 °C)5 E -155 °F (68 °C) F -155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), 360 °F (182 °C), and 500 °F (260 °C)5 G -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) U.S. metric2 Inches mm (Refer also to Design Criteria below.) Standard Orifice 5.6 57 A1,B2,C3, D1,E4,F6 5.6 80.6 2-1/4" 57 A1,B2,C3, D1,E4,F6 5.6 80.6 2-1/4" 57 A1, G5, D1, E4, F6 Approved Finishes 1 -Brass, Chrome, White Polyester4, and Black Polyester4 2 -Wax-Coated Brass (corrosion resistant) 3 -High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient temperature allowed at ceiling = 150 °F (65 °C) 4 -Wax-Coated Brass and Wax Over Polyester5 5 -White Polyester and Wax-Coated Brass (corrosion resistant) 6-ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Other colors are available on request with the same Approvals as the standard colors. 5 Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6 FM approved as corrosion resistant. FM Approval Requirements: The Viking Micromatic® Standard Response Upright Sprinkler VK100 is is FM Approved as standard response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Bulletin Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052014 19.10.14 Rev 19.1 Page 6 of 6 'IIKINGi ® TECHNICAL DATA MICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VK100 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler wrench 13577W/B** must be used for installing ________ __. wax coated sprinklers. Step 1: Carefully slide the wrench sideways around the deflector, ensuring engage- ment with the sprinklger wrench flats. Wax Coated Upright Sprinkler ** A 1/2" ratchet is required (not available from Viking) Step 2: Carefully press the wrench downward and ensure engagement with the sprinkler wrench flats. Figure 2: Socket Wrench 13577W/B for Wax Coated Sprinklers Form No. F _052014 19.10.14 Rev 19.1 Replaces Form No. F _052014 Rev 17.1.P65 (Added ENT; updated FM language.) Page 1 of 7 TECHNICAL DATA I MICROMATIC® STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION The Viking Micromatic® Standard Response Pendent VK102 Sprinkler is a small , thermosensitive, glass-bulb spray sprinkler available in several different finishes and temperature ratings to meet design requirements. The special Polyester, and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are listed/approved as indicated in the Approval Charts. Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering Instructions. 2. LISTINGS AND APPROVALS c@us cULus Listed: Category VNIV <8> FM Approved: Classes 2001, 2002, 2015, 2017, 2043 ~ VdS Approved: Certificate G414006 & G414004 Q LPCB Approved \"~ $ ( E CE: Standard EN 12259-1, DOP _Sprinklers_LPCB_5-2-19 & DOP _VK102WAX_2-12-19 MED Certified: Standard EN 12259-1 , EC-certificate 0832-MED-1003 China Approval: Approved according to China GB standard. NOTE: Other International approval certificates are available upon request. Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSPT Nominal K-factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (57 mm) * cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). **Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-C51000 (Not for FM Approval) or Copper UNS-C19500 Bulb: Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT coated Sprinklers: Belleville Spring -Exposed, Screw and Pipcap -ENT plated. Ordering Information: Refer to Table 1 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions,· the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. Form No. F _031414 20.10.20 Rev 20.1 Replaces Form No. F _031414 Rev 19.2 (Revised CE approval) Page 2 of 7 "IKING® TECHNICAL DATA MICROMATIC® STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 7. AVAILABILITY The Viking Micromatic® Standard Response Upright Sprinkler VK100 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: ORDERING INFORMATION Instructions: Using the sprinkler base part number, (1) add the suffix for the desired Finish (2) add the suffix for the desired Temperature Rating. Sprinkler Size 1: Finishes 2: Temperature Ratings Base Part NPT BSPT Description Sufflx1 Nominal Bulb Hazard Max. Ambient Ceiling Suffix No. Inch mm Rating Color Classification Temperature2 12987 1/2 --Brass A 135 °F (57 °C) Orange Ordinary 100 °F (38 °C) A 12989 --15 Chrome F 155 °F (68 °C} Red Ordinary 100 °F (38 °C) B 20229 --15 White Polyester 3•5 M-/W 175 °F (79 °C} Yellow Intermediate 150 °F (65 °C) D Black Polyester 3.5 M-/B 200 °F (93 °C) Green Intermediate 150 °F (65 °C) E Wax C 212 °F (100 °C) Green Intermediate 150 °F (65 °C) M Wax over Polyester V-/W 286 °F (141 °C) Blue High 225 °F (107 °C) G ENT 3.4.5 JN 360 °F (182 °C) Mauve Extra High 300 °F (149 °C) H 500 °F (260 °C) Black Ultra High6 465 °F (240 °C) L Example: 12987MB/W == VK102 with White Polyester Finish and 155 °F (68 °C) Nominal temperature rating. This sprinkler is to be installed into an area with a maximum ambient temperature of 100 °F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature-rated sprinkler. Corrosion Resistant Coatings5 . White Polyester and Black Polyester in all temperature ratings . . ENT in all temperature ratings except 135 °F (57 °C) . . Wax-Coated Brass and Wax over Polyester7 for sprinklers with the following temperature ratings: 155 °F (68 °C) Lt. Brown Wax I 175 °F (79 °C) Brown Wax I 200 °F (93 °C) Brown Wax I 286 °F (141 °C) Dk. Brown Wax7 Accessories Sprinkler Wrenches (see Figure 1 ): A. Standard Wrench: Part No. 21475M/B B. Standard Wrench for Wax Coated Sprinklers: Part No. 10896W/B C. Socket Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B (A 1/2" ratchet is required, not available from Viking) D. Socket Wrench for Wax Coated Sprinklers: Part No. 13577W/B (A 1/2" ratchet is required, not available from Viking) E. Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool9: Part No. 15915 Sprinkler Cabinet: A. Up to 6 sprinklers: Part number 01724A (available since 1971). B. 6-12 Sprinklers: Part number 01725A (available since 1971). Footnotes 1. Where a dash(-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. UL Listed as corrosion resistant. 4. FM Approved corrosion resistant. s. The corrosion resistant and corrosion proofing coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart(s). These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. &. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), response time may be severely retarded 7-Wax melting point is 170 °F (76 °C) for 286 °F (141 °C) temperature rated sprinklers. For more inforamation regarding wax coatings, refer to Bulletin Form No. F _010201 . 8-Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F _051808. Form No. F _031414 20.10.20 Rev 20.1 "IKINQi ® TECHNICAL DATA I Page 3 of 7 MICROMATIC® STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Form No. F _031414 20.10.20 Rev 20.1 C Figure 1: Sprinkler Wrenches Nominal Pipe Engagement 2-1/4" (57 mm) Figure 2: Sprinkler Dimensions 7/16" (11 mm) D Page 4 of 7 \IIKINCG ® TECHNICAL DATA MICROMATIC® STANDARD RESPONSE PENDENT SPRINKLER VK102 (KS.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 1 (UL) I Temperatu,e KEY I Micromatice Standard Response Pendent Sprinkler VK102 + Finish Maximum 175 PSI (12 bar) WWP A1X • Escutcheon (if applicable) Sprinkler Thread Size Nominal Overall Length Listings and Approvals3 Base Part SIN K-factor (Refer also to UL Design Criteria.) Number1 NPT BSPT U.S. metric2 Inches mm cULus4 VdS LPCB CE8 MED9 China Approval 12987 VK1O2 1/2" 15 mm 5.6 80.6 2-1/4" 57 A1,B3, B1Y,C4,D2,E5,G5Z A1 A1, B3, B1Y F1, G1Y, F2X --B412 12989 VK1O2 --15 mm 5.6 80.6 2-1/4" 57 A1,B3,B1Y,C4,D2,E5,G5Z A1 A1, B3, B1Y F1 , G1Y, F2X --B412 2022910 VK102 --15 mm 5.6 80.6 2-1/4" 57 E6 --------E6 ·---·~--· 7iTil1Til~ !T:Jle 1,,,~•••f•tt ffft • '~I •J••. 10139 VK1O2 1/2" 15 mm 5.6 80.6 2-1/4" 57 A1,B3,B1Y,C4,D2,E5,G5Z ---------- 10173 VK1O2 --15 mm 5.6 80.6 2-1/4" 57 A1,B3,B1Y,C4,D2,E5,G5Z A1 A1, B3, B1Y --F2X -- 18020 VK1O2 1/2" 15 mm 5.6 80.6 2-1/4" 57 A1,B3,B1Y,C4,D2,E5,G5Z A1 A1, B3, B1Y F1, G1X F2X -- Approved Temperature Rating Codes A= 135 °F (57 °C}, 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 360 °F (182 °C) B = 135 °F (57 °C}, 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) C = 286 °F (141 °C) D = 500 °F (260 °C)7 E = 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C}, 286 °F (141 °C), 360 °F (182 °C), and 500 °F (260 °C)7 F = 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), and 360 °F (182 °C) G = 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Approved Finish Codes 1 = Brass, Chrome, White Polyester5·6 and Black Polyester5·6 2 = Brass and Chrome 3 = Wax-Coated Brass and Wax Over Polyester5 4 = High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient temperature allowed at ceiling = 150 °F (65 °C) 5= ENT5 6 = Chrome Approved Escutcheon Codes X = Recessed with the Viking Model E-1, E-2, or E-3 Recessed Escutcheon Y = Standard surface-mounted escutcheon or recessed with the Viking Model E-1 , E-2, or E-3 Recessed Escutcheon Z = Standard surface-mounted escutcheon or recessed with the Viking Model E-1 Recessed Escutcheon Footnotes 1. Base part number is shown. For complete part number, refer to Viking's current price schedule. 2. Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. J. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. s. cULus Listed as corrosion resistant. &. Other colors are available on request with the same Listings and Approvals as the standard colors. 1. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. a. CE: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-0021. 9. MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. 10.Approved according to China GB standard. 11.CE: Standard EC 12259-1 , Declaration of Performance DOP _Sprinklers_LPCB_5-2-19 & DOP _VK102WAX_2-12-19 DESIGN CRITERIA -UL (Also refer to Approval Chart 1.) cULus Listing Reaujrements: The Viking MicromaticO® Standard Response Pendent Sprinkler VK1O2 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light, Ordinary, and Extra Hazard occupancies. • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F _031414 20.10.20 Rev 20.1 TECHNICAL DATA Page 5 of 7 MICROMATIC® STANDARD RESPONSE PENDENT SPRINKLER VK102 {K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart 2 (FM) I ~ Temperaw,e KEY ,I Mlcromatlc" Standard Response Pendent Sprinkler VK102 Finish A~ Escutcheon (If applicable) Maximum 175 PSI (12 bar) WWP Sprinkler Base Thread Size Nominal K-Factor Overall Length FM Approvals3 Part Number1 SIN NPT BSPT U.S. metric2 Inches mm (Refer also to Design Criteria below.) 12987 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 A1,B2,C3,D1,E4,G1Y,G4Z 12989 VK102 --15 mm 5.6 80.6 2-1/4" 57 A1,B2,C3,D1,E4,G1Y,G4Z 202297 VK102 --15 mm 5.6 80.6 2-1/4" 57 E5 NOTICE -Product Below -Limited Availability (Contact Local Viking Office) 10139 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 A1,B2,C3,D1,E4,G1Y,G4Z 10173 VK102 --15 mm 5.6 80.6 2-1/4" 57 A1,B2,C3,D1,E4,G1Y,G4Z 18020 VK102 1/2" 15 mm 5.6 80.6 2-1/4" 57 A1, B2, C3, D1, G1Y Approved Temperature Rating Codes A= 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 212 °F (100 °C), 286 °F (141 °C), and 360 °F (182 °C) B = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 212 °F (100 °C) C = 286 °F (141 °C) D = 500 °F (260 °C)5 E = 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 °F (141 °C), 360 °F (182 °C), and 500 °F (260 °C)5 F = 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) G = 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Approved Finish Codes 1 = Brass, Chrome, White Polyester5·6 and Black Polyester5•6 2 = Wax-Coated Brass (corrosion resistant) 3 = High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient temperature allowed at the ceiling = 150 °F (65 °C) 4 = ENT6 5 = Chrome Approved Escutcheon Codes Y = Standard surface-mounted escutcheon or recessed with the Viking Model E-1, E-2, or E-3 Recessed Escutcheon Z = Standard surface-mounted escutcheon or recessed with the Viking Model E-1 Recessed Escutcheon Footnotes 1. Base part number is shown. For complete part number, refer to Viking's current price schedule. 2. Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4. Other colors are available on request with the same Approvals as the standard colors. s. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 6. FM approved as corrosion resistant. 1. Approved according to China GB standard. DESIGN CRITERIA -EM (Also refer to Approval Chart 2.) FM Approval Regujrements: The Viking Micromatic® Standard Response Pendent Sprinkler VK102 is is FM Approved as standard response Non-Storage pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F _031414 20.10.20 Rev 20.1 "IKINGi ® TECHNICAL DATA Page 6 of 7 MICROMATIC® STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 21 O N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com STANDARD FINISHES Step 1: Carefully slide the wrench sideways around the protective cap, ensuring engagement with the wrench flats. WAX COATED Step 1: Carefully slide the wrench sideways around the protective cap (not shown}, ensuring engagement with the wrench flats. Figure 3: Installation with Recessed Wrenches *Requires a 1/2 ratchet -not available from Minimax. Form No. F _031414 20.10.20 Rev 20.1 13655W/B* Step 2: Carefully press the wrench upwards to engage with the wrench flats. 13577W/B* Step 2: Carefully press the wrench upwards to engage with the wrench flats. "IKINGi ® TECHNICAL DATA Page 7 of 7 MICROMATIC® STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1-1/8" (29 mm) Minimum ♦ Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum Installed with a standard 1/8" surface-mounted escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) ma?Cimum 1-3/4" (45 mm) Maximum 1-1/8" (29 mm) Minimum ! (51 mm) Maximum ♦ t Installed with a Model E-1 Recessed Escutcheon Installed with a Model E-2 Thread-on Recessed Escutcheon Figure 4: Installation Dimensions with Escutcheons Form No. F _031414 20.10.20 Rev 20.1 Replaces Form No. F _031414 Rev 19.2 (Revised CE approval) 'JIKINCG ® TECHNICAL DATA Page 1 of 6 MIRAGE® STANDARD RESPONSE CONCEALED PENDENT SPRINKLER VK492 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 1. DESCRIPTION Viking Mirage® Standard Response Concealed Pendent Sprinkler VK492 is a thermosensitive glass-bulb spray sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile cover assembly that provides up to ½" (13 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The The "push-on" and "thread-on" designs of the concealed cover plate assemblies allow easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS c@us cULus Listed: Category VNIV <8> FM Approval: Class 2015 Refer to the Approval Charts and Design Criteria listing and approval requirements that must be followed . 3. TECHNICAL DATA Specifications: Product release: 2016 Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar) /i\ WARNING: Cancer and Reproductive Harm- Factory tested hydrostatically to 500 psi (34.5 bar) ~ www.P65Warnings.ca.gov Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric*) Glass-bulb fluid temperature rated to -65°F (-55°C) Patents Pending * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UN S-C 19500 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 5 mm diameter Pip Cap and lnsertAssembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Yoke: Phosphor Bronze UNS-C51000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. Form No. F _101615 20.07.13 Rev 20.2 Replaces Form No. F _101615 Rev 20.1 ( added cover plate options) Page 2 of 6 I I I I TECHNICAL DATA MIRAGE® STANDARD RESPONSE CONCEALED PENDENT SPRINKLER VK492 (KS.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinklers VK492 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: (1) Select a Sprinkler Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the desired Sprinkler Temperature Rating (4) Order a cover plate (refer to Table 2) Example: 20034AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Sprinkler Size 1: Finishes 2: Temperature Ratings SIN Base Part NPT BSPT Sprinkler Max. Ambient Number Inch Description Suffix Temperature Nominal Rating Bulb Color Ceiling Suffix mm Classification Temperature1 VK492 20034 1/2 --Brass A Ordinary 155 °F (68 °C) Red 100 °F (38 °C) B Intermediate 175 °F (79 °C) Yellow 150 °F (65 °C) D Intermediate 200 °F (93 °C) Green 150 °F (65 °C) E Accessories Sprinkler Wrenches and tools: A. Heavy Duty Part Number: 14047W/B2 (available since 2006) B. Head Cabinet Wrench Part Number: 140313 (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 144124 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 148674 (available since 2007) Sprinkler Cabinet: Holds up to 6 sprinklers: Part number 01731A (available since 1971 ). Footnotes 1. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 2. Requires a ½" ratchet (not available from Viking). 3. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 4. The installer tool is for push-on style cover plates only. FormNo.F_101615 20.07.13 Rev20.2 "IKINGi® TECHNICAL DATA Page 3 of 6 MIRAGE® STANDARD RESPONSE CONCEALED PENDENT SPRINKLER VK492 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: (1) Select a Cover Plate Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the required Cover Plate Nominal Rating. Example: 23190MC/W = 165 °F (74 °C) Temperature Rated, 2-3/4" (70 mm) diameter, Thread-On style Round Cover Plate with a Painted White finish. 23190 23174 23179 Size Inch (mm) 2-3/4 (70) 3-5/16 (84) 3-5/16 (84) Cover Plate Nominal Rating (Required) 135 °F (57 °C) UL 139 °F (59 °C) FM 165 °F (74 °C} Footnotes Type Round 23447 Round 23463 Square 3: Temperature Rating Matrix1•2 Temperature Classification Ordinary Intermediate Sprinkler Nominal Rating 155 °F (68 °C} 175 °F (79 °C) 200 °F (93 °C) 1. The sprinkler temperature rating is stamped on the deflector. 2: Select a Finish Description Brushed Brass Brushed Copper Painted White Painted Ivory Painted Black Sprinkler Maximum Ambient Ceiling Temperature2 100 °F (38 °C) 150 °F (65 °C) F F-/B B B-/A B-/B E-/B M-/W M-/1 M-/B Suffix A C 2. Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4. Where a dash(-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. s. Square cover plates 23179 and 23482 cULus Listing is for the 135 °F (57 °C) temperature rated cover plate only. Refer to the Approval Chart. All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 1: Identification of Custom Paint for Concealed Covers Form No. F _101615 20.07.13 Rev 20.2 3-5/16" (84 mm) Figure 2: Square Cover Assembly 'JIKINCG® TECHNICAL DATA Page 4 of 6 MIRAGE® STANDARD RESPONSE CONCEALED PENDENT SPRINKLER VK492 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. Approval Chart r· ~--Sp~i~kler Temperat~~~ R~ting 1 l ,f · -Cover Plate Temperature Rating ! Mirage® Standard Response Concealed Pendent Sprinklers VK492 I AW1◄ Cover Plate Finish KEY J '-----. ---------------- NPTThread Nominal Maximum Listings and Approvals4 Sprinkler SIN Size K-Factor Water Working (Refer also to Design Criteria) Base Part No.1 Inch I mm U.S. I metric2 Pressure3 cULus5 FM3 20034A VK492 1/2" I 15 5.6 I 80.6 175 psi (12 bar) AV1, BX1 AW1, BY1 Cover Plate Assembly Temperature Ratings1•6 V -135 °F (57 °C) cover 23190, 23447, or 23174, 23463 (large diameter}, or 23179, Cover Plate Assembly Finishes7 Sprinkler Temperature Ratings 23482 (square cover plate} 1 -Polished Chrome, Brushed Chrome, A-155 °F (68 °C) W -139 °F (59 °C} 23190, 23347, or 23174, 23463 (large diameter}, or 23179, 23482 Bright Brass, Antique Brass, Brushed (square cover plate} B -175 °F (79 °C) and 200 °F (93 °C} X -165 °F (74 °C) cover 23190, 23447 or 23174, 23463 (large diameter) Brass, Brushed Copper, Painted Y -165 °F (74 °C) cover 23190, 23447 or 23174, 23463 (large diameter), or 23179, White, Painted Ivory, or Painted Black 23482 (square cover plate) Footnotes 1. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. The Water Working Pressure rating is stamped on the deflector. 4. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. s. Listed by Underwriter's Laboratories for use in the U.S. and Canada. &. The 135/139 °F cover has an orange label. The 165 °F (74 °C) cover has a white label. 1. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. DESIGN CRITERIA -UL (Also refer to Approval Chart) cULys Listing Requirements: Mirage® Concealed Pendent Sprinklers VK492 are cULus Listed as standard response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies including Light Hazard, Ordinary Hazard (Group 1) and Ordinary Hazard (Group 2). • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). • Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. • The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA or other similar organizations, and also with the provi- sions of governmental codes, ordinances, and standards, whenever applicable. Form No. F _ 101615 20.07 .13 Rev 20.2 Page 5 of 6 ! "IKINGi® TECHNICAL DATA MIRAGE® STANDARD RESPONSE CONCEALED PENDENT SPRINKLER VK492 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. DESIGN CRITERIA -EM (Also refer to Approval Chart) FM Approval Requirements: Viking Concealed Pendent Sprinkler VK492 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F _091699 -Care and Handling of Sprinklers. Also refer to Form No. F _080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Step 2: t t 2-1/4" (57 mm) diameter opening required in the ceiling. Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat -~-·.:.! '-""'~--•--..-..ca Sprinkler frame arms Figure 3: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) FormNo.F_101615 20.07.13 Rev20.2 TECHNICAL DATA Page 6 of 6 MIRAGE® STANDARD RESPONSE CONCEALED PENDENT SPRINKLER VK492 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page. 1/2" (15 mm) NPT 2-9/16" (65 mm) Maximum NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16" (21 mm) below the sprinkler body. 2-1/16" (52 mm) Minimum 2-3/4" (70 mm) or 3-5/16" (84 mm) Figure 4: Sprinkler Dimensions and Cover Installation Form No. F _101615 20.07.13 Rev 20.2 Replaces Form No. F _101615 Rev 20.1 (added cover plate options) Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A 123 standards. All products are stencilled to meet FM & UL specifications. c®usLISTED <19 APPROVED [I) NFP/t ., .. \ ONFSA Afflerloan .... ,,_.__ ... ,_..,,............, ~~Oft 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-114 ·~----;r ___ 1.660 --~-··. i --1.442 ~~~·1r=--9.91 _ _ _I[~ 1.81 lbs/ft =: L___ 2.518 -~--JC------61 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 --i--·----~1-6.27 =!r: 2.64 lbs/ft ~:c 4.223 -.----37 ______ 1 _____ 2.375 l 2.157 i1 q., __ ! 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 -~ -;,--3.260 =r=-3.54 =-~[ 4.34 lbs/ft }C_ 1.957 --r----19 3 ________ : __ _ 3.500 _J l_ ~---~ -------- 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 . ·:-_ I 1-:_-__ --1.660 ··-1, 1.380 ---ll -~ 1.00 ~-------,r-2.27 lbs/ft --1~--2.918 !1 51 11 .._._ ---·-1, 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 --~---l ----:r. :~~ 1.00 =l[ ---, .----5.114 -~ -1: --2 _,.,._ ... __ ..,,.., ..,,i __ ., -2.375 2.067 3.66 lbs/ft 11 30 2-1/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* --=Jc· 3.500 =-Jr~-~ 3.068 .~-~-I[=~-1.00 r-_ 7.58 lbs/ft '/ ~ 10.783 __ I ____ ii 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. BULL MOOSE TUBE COMPANY For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent,WA Casa Grande, AZ. www.bullmoosetube.com sales@bullmoosetube.com Dallas, TX Masury, OH Bull Moose Tube's® Eddythread 40® is a lightweight replacement for Schedule 40 that has a Corrosion Resistance Ratio of 1 . c®usLISTED <:@> APPROVED Ci.) NFPM ., .. \ ONFSA Atneffcan Fire ,..__,.,,._..,..,.........,.~ ~Anocla11on ADVANTAGES OF BULL MOOSE TUBE® EDDYTHREAD 40® • Has a Corrosion Resistance Ratio of 1.0. • Has a pressure rating of 300 psi. • Is lighter weight than Schedule 40. • Is approved by Factory Mutual and listed by Underwriters Laboratories. • Is produced in accordance to ASTM A 135 and A795 Type E, Grade A. • Can be used with standard Schedule 40 threaded fittings, couplings, and valves. • Is produced from steel with excellent properties of strength and threadability. • Can be used in wet, preaction, and deluge type sprinkler systems. • Can be hot dipped galvanized to meet FM's requirement for dry systems. • Offers lower freight costs. • Supplied with EDDY GUARD II ® MIC preventative coating. EDDYTHREAD 40® SPECIFICATIONS NOMINAL PIPE 0.0. 1.0. SIZE (IN) (IN) (IN) 1.295 1.083 1-114 ~~~=-1 c-·_ 1.650 :_--,r-_ --_ 1.418 1-1/2 1.900 1.654 2 ~r-2.375 ---1-· 2.123 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION CRR* 1.00 1.00 1.00 1.00 WEIGHT WATER FILLED BUNDLE LB./FT WEIGHT SIZE 1.461 1.860 70 2.070 --·r-· 2.154 ~ --I 51 I ---- 2.547 3.468 44 3.308 --,-4.842 -----30 ,' For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. BULL MOOSE TUBE COMPANY For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent,WA Casa Grande, AZ. www.bullmoosetube.com sales@bullmoosetube.com Dallas, TX Masury, OH 5 Bull Moose Tube's® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2". Eddylite® is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM A 135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®usLISTED ~ APPROVED Ci.I NFPM ., .. \ ONFSA ~..... ,...v.,. .. .,.,-._,...,..........., ~AHoclatlon 6 A□VANTAGES OF BULL MOOSE TUBE® E□□YLITE® • Standard outside diameter, unlike some other lightwall threadable pipe products. • Lighter in weight than Schedule 40. • Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. • Exceptionally strong, meets or exceeds ASTM A 135 minimum yield requirements. • Can be used with standard couplings, fittings, and valves. • Freight savings. • Lower sprinkler system costs without compromising service life. • Better hydraulics than Schedule 40. • Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10 ! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER PIPE SIZE (IN) 0.D. (IN) DIAMETER {IN) THREADED UNTHREADED PER FT. FILLED 1.315 1.137 0.13 7.47 1.260 1.700 1-1 /4 -:-~i C-:: 1.660 -r·-1.482 -t-0.08 ----; .---4.79 ----, ,---" 1.617 ---r-2.364 _:1 ,, 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 2 ----7i--2.375 -,r --2.177 --,r-0.16 If 4.31 ---r--2.617 l 4.230 j *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION BUNDLE SIZE 91 61 61 --!--ii 37 For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. BULL MOOSE TUBE COMPANY For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent,WA Casa Grande, AZ. www.bullmoosetube.com sales@bullmoosetube.com Dallas, TX Masury, OH • Bull Moose Tube's® Eddy Flow® is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's® larger ID provides an opportunity for downsizing and further cost savings. c®usLISTED ~ APPROVED [i] NFPM Aru o uFSA ......._. .... -11Jj ~••soci.· _,..,.,.. --- ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® • Certified to ASTM A 135 and A795 Type E, Grade A. • FM approved for roll grooving and welding for use in wet systems. • UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. • Lightweight -saves shipping costs and offers easier handling. • Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. • Can be supplied roll grooved or plain end. • Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. • Supplied with EDDY GUARD II® MIC preventative coating. NPS O.D. EDDY FLOW® EDDY FLOW® WEIGHT WATER FILLED BUNDLE SIZE {IN) (IN} (ID) CRR* PER FT. WT. SIZE 1-1/4 1.660 1.530 1.98 1.222 2.019 61 1-1/2 -------1.900 1.728 ~------3.44 -r---1.844 2.860 --ii---61 -•w -~ :1 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 . . ~ -4 4.500 4.310 1.00 4.968 11.290 19 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. BULL MOOSSTUSE COMPANY For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent.WA Casa Grande, Al. www.bullmoosetube.com sales@bullmoosetube.com Dallas, TX Masury, OH 7 Bull Moose Tube's® Ultra Eddy® is a versatile product that can be roll grooved, welded, and used with Pressfit* Products. c®usLISTED <§> APPROVED III NFPM am ONFSA A-Fire ,.,_,..,.,._ __ Sp,fnkl«AssoclM- B ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® • Certified to ASTM A 135 and A795 Type E, Grade A. • FM approved for roll grooving and welding for use in wet systems. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. • Lightweight -saves shipping costs, offers easier handling. • Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. • Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. • Can be supplied roll grooved or plain end. • With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. • Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS 0.0. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) {IN) EDDY® (ID) CRR** PER FT. FILLED WT. SIZE 1.315 1.201 2.17 .868 1.359 91 1-1/4 1: 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 -~ ------.. 2 2.375 2.261 1.00 1.604 3.344 37 * Pressfit is a Registered Trademark of Victaulic Company of America ** Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. BULL MOOSE TUBE COMPANY For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent,WA Casa Grande, AZ. www.bullmoosetube.com sales@bullmoosetube.com Dallas, TX Masury, OH NPS (IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 0.D.(in) .. -1.315 1.660 1.900 2.375 1.D. (in) 1.201 1.546 1.786 2.261 ULTRA EDDY9 l Empty Weight (lb/ft) 0.868 1.107 1.274 1.604 Water-Filled Weight (lb/ft) 1.359 1.920 2.360 3.~44 C.R.R. 2.17 1.40 1.11 1.00 0.D.(ln) --~~-:r-~~i[ 1.660 -,1.900 -.T 2.375 1r 2.875 ~~:-~ 3.500 4.500 I.D.(in) -L _ _ _____ I_ 1.530 ~{ 1.728 ~[ 2.203 :-[ 2.705 -1[-3.334 4.310 EDDY Flowe EmptyWeight(lb/ft) r·-----~_-_--ir 1.222 :_c 1.844 Jr 2.330 ~1C 2.809 :~r= 3.361 4.968 Water-FilledWeight(lblft) __ . ______ ,,1[ 2.019 _[ 2.860 _ I 3.982 .11 5.299 1;_ 7.144 11.290 C.R.R. ~-c __ ,, _ . l: 1.98 ~-~-; i 3.44 r ! 2.78 --1: 1 .66 -: :·-1.00 1.00 0.D.(in) =-J 1.315 1.660 1.900 2.375 2.875 3.500 4.500 I.D. (in) --7 1 .097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE . ; 10 EmptyWe1ght(lb/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 Water-FilledWeight(lb/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 C.R.R. __ I 15.27 9,91 7,76 6.27 4,92 3,54 2,50 0.D. (in) .I 1.315 1.660 1.900 ' 2.375 I.D.(in) --ir 1.137 1.482 -T 1.712 "!J 2.177 EDDYLIW~ Ir EmptyWeight(lb/ft) i.-1.260 ,) 1.617 ~1;-1.967 · 2.617 Water-Filled Weight {lb/ft) 1.700 : l 2.364 1 2.965 , L 4.230 --r .-:....,,-C.R.R. 1, 0.13 1 L 0.08 1 0.12 r 1 0.16 =-.::::-7 ----. 0.D. (in) ==-:! 1.295 1.650 1.900 2.375 EDDYTHREAD I' I.D. (in) ! 1.083 1.418 1.645 2.123 40e Empty Weight (lb/ft) ' 1.461 2.070 2.547 3.308 Water-Filled Weight (lb/ft) 1.860 2. 754 3.468 4.842 ® LISTED I ~==:;;;;::::l____..· C.R.R. ___ j 1.00 1.00 1.00 1.00 C us I 7c 0.D.[ln) =7! 1.315 :.r_ 1.660 ;l( 1.900 :_JC_. 2.375 ~c:.!-2.875 l 3.500 4.500 L I.D. (in) 71 1.049 '. i 1.380 I! 1.610 _ J ,_ 2.067 _, 1 2.469 3.068 4.026 ~ I SCH!~ULE r EmptyWeight(lb/ft) 1 ' 1.680 ];·: 2.270 [ 2.720 J[ 3.660 --:-::-5.800 -:-7.580 10.800 ~ Water-Fllk!dWeight(lb/ft) 2.055 ~[ 2.918 [ 3.602 ~~ 5.114 _;~~ 7.875 ~.-= 10.783 . r 16.316 APPROVED _ 1 L~---C.R.R. __ __J '-· 1.00 --i L_ 1.00 [ 1.00 __ J l __ 1.00 1.00 1 1.00 1.00 m A {)_ ,,.i//1 ._.,.. .. I\~-.®. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com LWJ ., ONFSA ~ ~· Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com NFPA® ~..!':ti-,,,,_,,..,..,__ -=cc,-r n -_j 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, Al Dallas, TX Masury, OH BULL MOOSE TUBE COMPANY 63017 ------------------,.-------------9 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDY® .1 0.868 91 1,659 1,896 1,975 SCHEDULE 10 ~ 1.410 91 2,695 3,079 3,208 EDOYLITE® 1.260 91 2,408 2,752 2,867 EOOYTHREAO 40® 1.461 70 2,148 2,454 2,557 SCHEDULE 40 ! 1.680 70 2,470 2,822 2,940 ULTRA EDDY® _] ,--~ 1.107 -·---c--=~ 61 ~=!L-=-1,418 -----1,621 ~ I -1,688 I EDDY FLOW® -] : -·-1.222 --L~ 61 ~-r-1,565 -----... _ -----1,789 ~=---, r=-. 1,864 Ii ,, __ -I 7--r-.....:::::...... _-_----~--- 1-1/4 l~ SCHEDULE 10 . .I 1.810 I 61 2,319 i 2,650 2,760 -11 --r··-----~· --·1-·· . ~ " ~ EDDYLITE® 1.617 2,071 ... 'i 2,367 ---I-~-2,466 I 61 I ---. -=-=--i....'.:........-=---= I - EDOYTHREAD 40® 1 2.070 1, 51 r~ 2,217 2,534 2,639 SCHEDULE 40 i r-,_ - 2.270 --·-11 ---,---2,431 -· 2,778 2,894 51 ULTRA EDDY® i 1.274 61 1,632 1,865 1,943 EDDY FLOW® 7 1.844 61 2,362 2,700 2,812 1-1/2 ! f-SCHEDULE 10 I 2.090 61 2,677 3,060 3,187 EDDYLITE® 1.967 61 2,520 2,880 3,000 EDDYTHREAD 40® 2.547 44 2,353 2,690 2,802 SCHEDULE 40 i 2.720 44 2,513 2,872 2,992 ULTRA EDDY® 71 --1.604 37 1,246 ---..a: -----1,424 1,484 EDDY FLOW® ~ 1----= 2.330 ::::--,:---= 37 =--=.;;~. r-·--=--1,810 -··-----2,069 --·--i--. 2,155 =-,.--=-----=-----=---=--r--=.:..:: __ ~-=-.r -==--·---SCHEDULE 10 2.640 37 ,I 2,344 2,442 2 I~ I ____ '( __ 2,051 I' ----=ir-·-~ =t-=----·------EOOYLITE® 2.617 ----l ---37 2,033 2,324 2,421 EDDYTHREAO 40® ( 3.308 ~~i----~-!1 2,084 i--~--~ 2,382 --------·· . -.. 2,481 __ l . _ 30 I J•• \ SCHEDULE 40 --~[_-_ = •r--2,306 ---,-----I 3.660 30 ,I 2,635 2,745 c®usLISTED I I I~ EDDY FLOW® 2.809 1,770 2,022 2,107 2-1/2 SCHEDULE 10 3.530 30 2,224 2,542 2,648 <§> I \ SCHEDULE 40* 5.800 3,654 4,176 4,350 I Ir EDDY FLOW® 3.361 --1 I -~-~---------r-· ~--1,341 -------. ,---:-~1 1,533 ---:· --~ 1,596 3 SCHEDULE 10 4.340 19 C-1,132 -· ---' ---1,979 -•--l ---2,062 APPROVED -----l __ --~ -----[~ ~-~-,------~ SCHEDULE 40* 7.580 3,024 I 3,456 3,601 III A L d I EDDY FLOW" 4.968 1,982 2,265 2,360 ONFSA 4 [ SCHEDULE10 5.620 19 2,242 2,563 2,670 AP-SA [ SCHEDULE 40* NFPA® ~Ion n.-... ..... ,.,,. ....... ......, 10.800 4,309 4,925 5,130 r----6 f SCHEDULE 10 ~ -I -~------(--9.289 I 10 1,951 2,229 2,322 8-1 SCHEDULE 10 16.940 7 2,490 2,846 2,965 10 * Only Available in Casa Grande, AZ. ® ' '·. :,.,,, ·:• ,.,..,,. I •. '. I . i. .-. /,l '' BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®usLISTED <§> APPROVED Ci.I NFPM A'tA \ ONFSA Att'Mfto.anFlre ,,._..,..,, .. ,_s.-wi-~ s,,,tnkler Asseclatbl Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing ( ft.) *** According to Pipe Transverse Brace Spacing* HLF for the 2006 & 2009 IBC ( ASCE 7-05) & Cp for NFPA-13 shown in BOLD TYPE Size 20 ft . 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1 1/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 2 1/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1012 867 726 40 40 40 40 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fp w) lbs. Max. Transverse and 4-way Brace Spacing ( ft.) *** According to Pipe Transverse Brace Spacing* HLF for the 2006 & 2009 IBC ( ASCE 7-05) & Cp for NFPA-13 shown in BOLD Size 20 ft. 25 ft. 30 ft. 1 119 95 78 11/4 218 175 143 11/2 312 250 205 2 518 414 339 BULL MOOSE TUBE COMPANY TYPE 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 67 56 40 40 36 31 28 25 24 123 103 40 40 40 35 31 28 26 175 147 40 40 40 37 33 30 28 291 243 40 40 40 40 36 33 30 For Additional Information Contact (800) 325-4467 Or From Canada Call: (800) 882-4666 1819 Clarkson Road Chesterfield, MO 63017 Gerald, MO Kent,WA Casa Grande, AZ. 2.00 2.25 2.50 2.75 22 21 20 19 25 23 22 21 26 25 23 22 29 27 26 24 www.bullmoosetube.com sales@bullmoosetube.com 3.00 18 20 21 23 Dallas, TX Masury, OH 11 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N Victaulic Mechanical-T® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HOPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap II® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. @<§>~~ SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLES 920 AND 920N STYLE 920 CROSS PATENTED MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. JOB/OWNER System No. _________ _ Location ___________ _ www.victaulic.com • Optional: Hot dipped galvanized Gasket: (Specify choice*) • Grade "E" EPDM EPDM (Green color code). Temperature range -30°F to +230°F/-34°C to +ll0°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade "T" nitrile Nitrile (Orange color code). Temperature range -20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. CONTRACTOR ENGINEER Submitted By ________ _ Spec Sect ____ _ Para ____ _ Date ____________ _ Approved __________ _ Date ____________ _ VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.© 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV N ~taulic" 11.02 1 CARBON STEEL PIPE -HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with H DPE pipe • Sizes from 2 x ½"/50 x 15 mm through 8 x 4"/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. 2 50 2½ 65 76.1 3 80 3½ 90 X X X X X ½ (a)o 15 ¾(a) 0 20 ] (a) 0 25 1 ¼ (a) to 32 1 ½ (a) to 40 ½ (a) §o 15 ¾(a) §o 20 1 (a) §o 25 1 ¼ t (a) o 32 1 ½ t (a) o 40 ½ (a) 15 ¾ (a) 20 1 (a) 25 ] ¼(a)o 32 1 ½ (a) 0 40 ½ (a)o 15 ¾ (a) o 20 1 (a) 25 1 ¼ (a) to 32 (b) 1 ½ (a) to 40 (b) 2 (a) 0 so 2 50 920N 500 1.50 3450 38.1 920N 500 1.50 3450 38.1 920N 500 1.50 3450 38.1 920N 500 1.75 3450 44.5 920N 500 1.75 3450 44.5 920N 500 1.50 3450 38.1 920N 500 1.50 3450 38.1 920N 500 1.50 3450 38.1 920N 500 1.75 3450 44.5 920N 500 2.00 3450 50.8 920N 300 1.50 2065 38.1 920N 300 1.50 2065 38.1 920N 300 1.50 2065 38.1 920N 500 1.75 3450 44.5 920N 500 2.00 3450 50.8 920N 500 1.50 3450 38.1 920N 500 1.50 3450 38.1 920N 500 1.50 3450 38.1 920N 500 1.75 3450 44.5 920N 500 2.00 3450 50.8 920N 500 2.50 3450 63.5 920N 500 2.50 3450 63.5 2.00 51 1.97 so 1.85 47 2.05 52 2.03 52 2.21 56 2.18 55 2.06 52 2.30 58 2.28 58 2.22 56 2.19 56 2.07 53 2.30 58 2.28 58 2.52 64 2.49 63 2.38 61 2.55 65 2.78 71 2.75 70 3.00 76 2.53 64 2.53 64 2.53 64 2.75 70 2.75 70 2.74 70 2.74 70 2.74 70 3.00 76 3.00 76 2.75 70 2.75 70 2.75 70 3.00 76 3.00 76 3.05 78 3.05 78 3.06 78 3.25 83 3.50 89 3.50 89 3.00 76 3.12 79 3.25 83 3.25 83 3.31 84 3.31 84 3.56 90 3.56 90 3.56 90 3.75 95 TABLE CONTINUED ON PG. 3 1.61 5.35 2.75 41 136 70 1.61 5.35 2.75 41 136 70 1.61 5.35 2.75 41 136 70 1.61 5.35 3.00 41 136 76 1.61 5.35 3.25 41 136 83 1.82 5.64 2.75 46 143 70 1.82 5.64 2.75 46 143 70 1.82 5.64 2.75 46 143 70 1.82 6.29 3.00 46 160 76 1.82 6.26 3.25 46 159 83 2.25 6.46 3.18 57 164 81 2.25 6.46 3.18 57 164 81 2.25 6.46 3.18 57 164 81 1.92 6.29 3.00 49 160 76 1.92 6.29 3.25 49 160 83 2.28 6.15 2.75 58 156 70 2.28 6.15 2.75 58 156 70 2.28 6.15 2.75 58 156 70 2.28 6.15 3.00 58 156 76 2.28 6.15 3.25 58 156 83 2.28 6.75 3.88 58 172 99 2.44 6.72 3.88 62 171 99 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. :j: Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. 3.1 1.5 3.1 1.5 3.0 1.4 3.5 1.7 3.6 1.7 3.0 1.4 3.0 1.4 2.9 1.4 3.5 1.7 3.6 1.7 3.9 1.8 3.9 1.8 3.8 1.7 3.5 1.6 3.5 1.6 3.4 1.6 3.4 1.6 3.3 1.6 3.8 1.8 4.1 1.9 4.9 2.3 (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. 3.2 1.5 3.2 1.5 3.2 1.5 3.3 1.6 3.2 1.5 3.3 1.5 3.7 1.8 3.8 1.8 4.6 2.1 3.8 1.8 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.© 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02 2 ~taulic' REV N CARBON STEEL PIPE -HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET • Provides a direct branch connection at any location where a hole can be cut in the pipe • A pressure responsive gasket provides the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HOPE pipe • Sizes from 2 x ½"/50 x 15 mm through 8 x 4"/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. 4 ½ (a) a 920N 500 100 X 15 3450 ¾(a) a 920N 500 20 3450 1 (a) o 920N 500 25 3450 1 ¼ (a) t a 920N 500 32 (b) 3450 i ½ (a) t a 920N 500 40 (b) 3450 2 (a) ta 920N 500 50 3450 2½ (a) t 920 500 65 3450 76.1 mm 920 500 3450 3 (a) t 920 500 80 3450 108.0 X 1 ¼ (a)o 920N 500 32 3450 1 ½ (a)a 920N 500 40 3450 2 (a) 920N 500 50 3450 76.1 mm 920 500 3450 3 (a) 920 500 80 3450 5 X 1 ½ (a) t 920 500 125 40 3450 2 (a) t 920 500 50 3450 2½ (a) t 920 500 65 3450 920 500 3450 3 (a) t 920 500 80 3450 133.0 X 2 920N 500 50 3450 3 920 500 80 3450 TABLE CONTINUED FROM PAGE 2 1.50 3.03 3.56 38.1 77 90 1.50 3.00 3.56 38.1 76 90 1.50 2.88 3.56 38.1 73 90 1.75 308 3.78 44.5 78 96 2.00 3.28 4.00 50.8 83 102 2.50 3.25 4.00 63.5 83 102 2.75 2.88 4.00 69.9 73 102 2.75 2.88 69.9 73 3.50 3.31 4.50 88.9 84 114 1.75 3.08 3.78 44.5 78 96 2.00 3.28 4.00 50.8 83 102 2.50 3.25 4.00 63.5 83 102 2.75 2.88 4.00 69.9 73 102 3.50 3.31 4.50 88.9 84 114 2.00 4.03 4.75 50.8 102 121 2.50 4.00 4.75 63.5 102 121 2.75 3.63 4.75 69.9 92 121 2.75 3.75 69.9 95 3.50 3.81 5.00 88.9 97 127 2.50 3.75 4.50 63.5 95 114 3.50 3.81 5.00 88.9 97 127 4.00 102 4.00 102 4.00 102 4.00 102 4.00 102 4.12 105 4.00 102 4.50 114 4.75 121 4.75 121 4.75 121 4.75 121 4.63 118 TABLE CONTINUED ON PG. 4 2.69 7.01 2.75 68 178 70 2.69 7.01 2.75 68 178 70 2.69 7.01 2.75 68 178 70 2.69 7.01 3.00 68 178 76 2.69 7.01 3.25 68 178 83 2.69 7.01 3.88 68 178 99 2.69 7.34 4.63 68 186 118 2.69 7.34 4.63 68 186 118 2.69 7.73 5.12 68 196 130 2.63 7.64 3.05 67 194 78 2.63 7.64 3.25 67 194 83 2.63 7.64 4.00 67 194 102 2.63 7.64 4.29 67 194 109 2.63 7.63 4.88 67 194 124 3.16 9.70 3.69 80 246 94 3.16 9.70 4.38 80 246 111 3.16 9.70 4.63 80 246 118 3.16 9.70 4.63 80 246 118 3.16 9.70 5.31 80 246 135 3.17 8.00 3.88 81 203 99 3.00 9.46 5.31 76 240 135 ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. =I= Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. 3.7 1.8 3.7 1.8 3.6 1.8 4.0 1.9 4.2 2.0 5.0 2.3 5.8 2.6 8.4 3.8 5.0 2.3 5.0 2.3 4.0 1.9 8.0 3.6 6.8 3.1 7.4 3.4 8.2 3.7 8.3 3.8 8.4 3.8 8.0 3.6 8.0 3.6 (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. 3.6 1.8 3.9 1.9 4.6 2.1 5.0 2.3 6.4 2.9 6.4 2.9 7.8 3.5 6.5 3.0 7.6 3.4 8.0 3.6 7.9 3.6 8.0 3.6 8.8 4.0 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.© 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV N ~tauhc· 11.02 3 CARBON STEEL PIPE -HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS r ~t~rt;i 1 ½t 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 ~-i i 139.7 X 40 920N 3450 50.8 96 114 84 209 83 3.2 2 t 920N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 3450 63.5 95 114 84 209 99 4.1 6 X 1 ¼(a) 920N 500 1.75 4.43 5.13 5.13 3.79 9.15 3.25 5.1 4.8 150 32 (b) 3450 44.5 112 130 130 96 232 83 2.3 2.2 GROOVED OUTLET 1 ½ (a) ta 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 5.1 40 (b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2 (a) ta 920N 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 50 3450 63.5 111 130 130 96 232 99 2.7 2.5 rfi:'~ rr z~ 2½ 920 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 I 65 3450 69.9 110 130 130 94 267 118 3.8 3.4 1Q 920 500 2.75 4.15 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 132 94 267 118 3.8 3 (a) t 920 500 3.50 4.31 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 4.5 3.8 4 (a) ta 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 114.3 97 146 137 94 267 159 4.6 4.6 FEMALE THREADED OUTLET 1 ½(a) 500 2.00 5.13 3.63 9.40 3.25 7.8 159.0 X 920N 4.41 40 3450 50.8 112 130 92 239 83 3.5 2 (a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 • Provides a direct branch connection at 50 3450 63.5 111 130 92 239 99 3.6 any location where a hole can be cut 76.1 mm 920 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 in the pipe 3450 69.9 111 140 130 92 239 118 4.3 4.3 3 920 500 3.50 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 • A pressure responsive gasket provides 80 3450 88.9 110 140 130 92 239 135 3.7 6.4 the seal 108.0mm 920 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 3450 114.3 113 137 92 239 155 4.5 • Request Publication 11.03 for 4 920 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 Mechanical-T cross assemblies 100 3450 114.3 96.80 146 92 239 159 8.2 TABLE CONTINUED ON PG. 5 • Pressure rated up to 500 psi/3450 kPa ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). on steel pipe; also available for use t Available with grooved or female threaded outlet. Specify choice on order. with HOPE pipe :J: Center of run to end of fitting. • Sizes from 2 x ½"/50 x 15 mm # Female threaded outlets are available to NPT and BSPT specifications. through 8 x 4"/200 x 100 mm @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services IMPORTANT NOTES: 0 Approved for use in China by Tianjin Approvals Company. Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02 4 "\.htaul;c" REV N CARBON STEEL PIPE -HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS r iD1 rt;i 1 500 1.50 3.88 4.56 3.79 9.34 2.75 8.0 ~1W 165.1 X 25 920N 3450 38.1 99 116 96 237 70 3.6 l¼n 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 8.4 32 3450 44.5 113 130 96 237 83 3.8 1 ½ (a) tn 920N 500 2.00 4.41 5.13 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 GROOVED OUTLET 2 (a) t 920N 500 2.50 4.38 5.13 5.13 3.79 9.34 3.88 8.5 6.0 so 3450 63.5 111 130 130 96 237 99 3.9 2.7 76.1mm 920 500 2.75 401 5.13 5.21 3.63 10.51 4.63 8.6 7.6 3450 69.9 110 130 132 92 267 118 3.9 3.4 rfr'~ r,=z~ 3(a)t0 920 500 3.50 4.31 5.50 5.13 3.63 10.51 5.31 10.2 8.4 I 80 3450 88.9 110 140 130 92 267 135 4.6 3.8 ls -~ 4 (a) ta 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 3450 114.3 97 146 137 92 267 159 4.8 3.8 8 X 2 (a) t 920 500 2.75 5.44 6.19 6.25 4.81 12.42 4.50 11.6 11.6 200 so 3450 69.9 138 157 159 122 316 114 5.3 5.3 2½ (a) t 920 500 2.75 5.07 6.19 6.19 4.81 12.42 4.50 11.6 11.6 65 3450 69.9 129 157 157 122 316 114 5.3 5.3 FEMALE THREADED OUTLET 500 2.75 5.25 6.25 4.81 12.42 4.56 11.6 920 3450 69.9 133 159 122 316 116 5.3 3 (a) ta 920 500 3.50 5.31 6.50 6.50 4.81 12.42 5.31 12.6 11.6 • Provides a direct branch connection at 80 3450 88.9 135 165 165 122 316 135 5.7 5.3 any location where a hole can be cut 4 (a) ta 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 in the pipe 100 3450 114.3 122 171 162 122 316 159 6.9 5.7 • A pressure responsive gasket provides ** Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). the seal • Request Publication 11.03 for Mechanical-T cross assemblies • Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HOPE pipe • Sizes from 2 x ½"/50 x 15 mm through 8 x 4"/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com t Available with grooved or female threaded outlet. Specify choice on order. =I= Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ~taulid 11.02 5 REV N CARBON STEEL PIPE -HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. @ Cv and Kv Values I Values for flow of water at +60°F/+l6°C are shown in the table below. Formulas for Cv ,K., Values: 6P = Q2 C} Where: Q = Flow (GPM) 6P = Pressure Drop (psi) Cv = Flow Coefficient Exaggerated for clarity ¾ 1.050 20 26.7 1 1.315 3"' 25 33.7 1¼ 1.660 32 42.7 S½ 1½ 1.900 40 98.3 11 2 2.375 so 60.3 9 2½ 2.875 65 73.0 20 76.1 mm 3.000 16* 76.1 3 3.500 80 88.9 14 4 4.500 100 114.3 20 t Hazen-Williams coefficient of friction is 120. * Pipe with a wall thickness of 0.165in./4.2mm. ** 1" Firelock™ Innovative Groove System (IGS) outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.© 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02 6 4 8 6 11 10 ½ 12 ½ 15 ½ 22 6P = Q2 Q =K .. xJii" so 42.9 53 45.4 112 96 119 102 161 138.1 249 213.4 421 360.8 Where: Q = Flow (m3/hr) 6P = Pressure Drop (Bar) Kv = Flow Coefficient 16 13.7 21 1.8 48 41.1 53 45.4 104 89.1 150 128.5 237 203.1 401 343.6 ~taul;d REV_N CARBON STEEL PIPE -HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Approval Agency Run Size Outlet Size Pipe Rated Working Pressures -ps1/kPa •'-':t ~ '::)i•ti,, ;1.,f.~k; r:} A'ttuait 'f' 1 '.:, • ,' _ ' ,; .'':/ ·-·,' .':--~1;;~:' { ., , • t· · :•, ·, :· . , >. ,_ ~, {,.:,;,,:--:.-.:/~ :: • ,j~\ ~i,tt:", ,;;j .:::-:~, •,, ·,.:;: ',: .'\ 1' , '-•• ' N. ,:, , ,_, ' :. ,· .' . , :·,] ;•f'NL .~-1~•,,_:11~,)lOt 'd'·•~,{':.t""'' '> '~ti "·"'··•·, ,,·,,~ .,,. ,,. ~-., _.,,,,il;,i., lfl•'''ll;;'1~·>-"'.¥'t',jf ;_,¥'1)\ir:, ... .:\1w:,;--~.-~~Vdst'"-'~ ~-.,ii"'➔ ~;•· M.us1e -\ii· :i,;;,,r,~,.,~-·h,, •• t,,m -•~,--,,· ',, J,·.\;,1~,.1,,,:,,1 <_,,:~•, ~'•-·· i,t:l•'-~~,,.,• •· . •' ~,.,,, .. , ,~,;:;, : ,:~.-"~.£.iame~er J ·•@~,i-~I,~~ ~;':'I ;~,if~ 1~i1{if·is"':-)i"~~~\·;)~J ?1'11~~~ '!tr. ·*-~! i?!~;;-fl: i!~,~~l,:~~,~ii~1 m Inches/mm Inches/mm Scheoule" •1'l i~Ul! ~-~UL:.C , ,FM l.!P.CB ~ (Style 920N) 21/2 -6 2.875 -6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 2496 21/2 -4 2.875 -4.500 All DF 300 300 300 290 232 362 65 -100 73.0 -114.3 2065 2065 2065 1999 1599 2496 21/2 -4 2.875 -4.500 All SF 300 300 300 290 232 362 65 -100 73.0 -114.3 2065 2065 2065 1999 1599 2496 6 6.625 3, 4 10 300 300 250 290 232 362 150 168.3 2065 2065 1724 1999 1599 2496 6 6.625 3,4 30,40 300 300 300 290 232 362 150 168.3 2065 2065 2065 1999 1599 2496 8 8.625 21/2 10, 40 400 ---145 -200 219.1 2755 1000 8 8.625 3,4 10 300 -250 -145 -200 219.1 2065 1724 1000 8 8.625 3,4 30,40 300 -300 -145 -200 219.1 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 -8"/100 -200 MM CARBON STEEL PIPE www.victaulic.com The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4'/lO0mm, 5"/125 mm, 6'/150 mm and 8"/200 mm diameter pipe. The Style 931 comes with a 2 ½"/65 mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.© 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV N ~taulic' 11.02 7 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N INSTALLATION WARRANTY NOTE Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com ~t.aulic' 11.02 1480 REV N UPDATED 12/2017 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02 L Firelock® Outlet-T STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, ¾, and l"/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1 ¼ through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-Tis UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. JOB/OWNER System No. __________ _ Location ___________ _ www.victaulic.com Gasket: • Grade "E" EPDM -Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel (North America, Latin America, Asia Pacific) • Red enamel (Europe) CONTRACTOR ENGINEER Submitted By ________ _ Spec Sect ____ _ Para ___ _ Date ____________ _ Approved ___________ _ Date ____________ _ VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.© 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV G ~taulic' 10.52_1 IPS CARBON STEEL PIPE -HOLE CUT PRODUCTS 10.52 Firelock® Outlet-T STYLE 922 DIMENSIONS l¼ X ½ 13/16 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 ¾ P/i6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 P/i6 1.52 2.18 1.10· 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1½ X ½ P/i6 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 ¾ Pli6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 P/i6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31 .0 103.6 65.0 0.59 2 X ½ P/i6 1.66 2.19 1.46 4.60 2.56 1.3 so 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 ¾ P/i6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 P/i6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 2½ X ½ P/i6 1.91 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 ¾ PA6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 P/i6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 76.1 mm X ½ 13/16 1.91 2.44 1.71 5.50 2.56 1.6 15 30.2 48.5 62.0 43.4 139.7 65.0 0.73 ¾ P/i6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 P/i6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.© 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 2 ~taul;c' REV G IPS CARBON STEEL PIPE -HOLE CUT PRODUCTS Firelock® Outlet-T STYLE 922 PERFORMANCE """ 5,,,, 0,11,15,,, -.i,~1J1~1·"r•-~&)1J~J1m~ ~ 1¼ X 1 8.5 32 25 2.6 1½ X 1 8.5 40 25 2.6 2 X 1 8.5 50 25 2.6 2½ X 1 8.5 65 25 2.6 76.1 mm X 1 8.5 25 2.6 * Hazen-Williams coefficient of friction is 120 www.victaulic.com YICTAULIC IS A REGISTERED TRADEMARK OF YICTAULIC COMPANY. © 2009 YICTAULIC COMPANY. ALL RIGHTS RESERVED. REV G 10.52 ~taulic" 10.52 3 Firelock® Outlet-T STYLE 922 INSTALLATION WARRANTY NOTE Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com ~taulic' 10.52 3355 REV G UPDATED 12/2009 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.© 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 Ductile Iron Threaded Fittings I H-CO PE ® INTERNATIONAL Ductile Iron Threaded Fittings • <©> branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP • Ductile iron castings conform to ASTM A536 • Fitting dimensions conform to ASME 816.3 • Bushings and plugs conform to ASME 816.14 • Fittings are 100% air tested • NPT threads on all fittings conform to ASME B 1.20.1 c@us LISTED <8> APPROVED • Independent lab verification that fittings meet applicable chemical & physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 c@us~ Fig. 35E 3 -90° Elbow LISTED Size Part Number A Packin Weight in in Inner Master lb 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E 3014 1.94 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1 /2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 -90° Reducing Elbow B Size Part Number A B Packing Weight in in in Inner Master lb 3/4 X 1/2 35RE3006004 1.20 1.22 80 160 0.3 ,,--1 X 1/2 35RE3010004 1.26 1.36 70 140 0.4 -,--1 X 3/4 35RE3010006 1.38 1.45 50 100 0.4 -,~ --1-1/4x1/2 35RE3012004 1.34 1.53 35 70 0.5 ,~ ~ ~,,_ 1-1/4 X 3/4 35RE3012006 1.45 1.63 35 70 0.6 ,,~ ~ -1-1/4x1 35RE3012010 1.58 1.67 30 60 0.7 ,~ --1-1/2 X 1/2 35RE3014004 1.52 1.75 30 60 0.6 ,_ ---~ 1-1/2 X 3/4 35RE3014006 1.52 1.75 25 50 0.7 ,_ ----1-1/2 X 1 35RE3014010 1.65 1.80 20 40 0.8 --1-1/2x1-1/4 35RE3014012 1.82 1.88 18 36 1.0 - 2 X 1/2 35RE3020004 1.60 1.97 18 36 1.0 -~ ---2 X 3/4 35RE3020006 1.60 1.97 18 36 1.0 -,~ -,~ 2 X 1 35RE3020010 1.73 2.02 16 32 1.2 ~ _,_ 2x1-1/4 35RE3020012 1.90 2.10 12 -I"-24 1.3 ~ 2 X 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 ~ -1-2-1 /2 X 1-1 /2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2x2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3 -45° Elbow Size Part Number A Packin Weight in in Inner Master lb 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F 3010 1.13 40 80 0.5 IA 1-1/4 35F 3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3 -Tee Size Part Number A Packin Weight SA in in Inner Master lb 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 f--------+ f--------+ 1-1/2 35T 3014 1.94 10 20 1.5 A A 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com c@us~ Fig. 35RT3 -Reducing Tee LISTED Size Part Number A B C Packina Weight in in in in Inner Master lb 3/4 X 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 -1 X 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 -1 X 1/2 X 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 X 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 +----------t I t----------i B A 1 X 3/4 X 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 ,_ ,~ 1 X 3/4 X 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 ,_ 1-1/4x1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 X 1/2 X 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4 X 3/4 X 1-1/4 3~RT3012006012 1.75 1.62 1.75 20 40 ,_ 1.0 1-1/4 X 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4X 1 X 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 X 1 X 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4x1x1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4 X 1 X 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 X 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 X 1/2 X 1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1 /2 X 1 /2 X 1-1 /2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 X 3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 ,_ ~ 1-1/2 X 3/4 X 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 ,_ 1-1/2 X 3/4 X 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 ,_ 1-1/2 X 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1 /2 X 1 X 1 /2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 X 1 X 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2 X 1 X 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 ,~ 1-1/2 X 1 X 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 ,_ 1.2 1-1 /2 X 1 X 1-1 /2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 ,~ 1-1 /2 X 1-1 / 4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1 /2 X 1-1 /4 X 1 /2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 X 1-1/4 X 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 ,_ 1-1/2 X 1-1/4 X 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 ,_ 1-1/2 X 1-1/4 X 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 ,_ 1-1/2 X 1-1/4 X 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 1.-,_ 2 X 1/2 35RT3020004 1.49 1.49 1.88 10 20 , __ 1.5 -2 X 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 ,_ ,~ 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7 ·-~ ,_ 2 X 1 X 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 ·---,~ 2x1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 --- 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 ,_ --2 X 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 -2 X 1-1 /2 X 1 /2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 -, __ 2 X 1-1/2 X 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 ---2 X 1-1/2 X 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 --,_ 2 X 1-1/2 X 1-1/4 35RT3020014012 1.90 1.82 2.10 8 -16 ,_ 1.7 2 X 1-1 /2 X 1-1 /2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3 -Bull Head Tee Size Part Number A B C Packing Weight in in in in Inner Master lb 3/4 X 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 - '--'----1x1-1/4 ·-35BT3010012 1.67 1.67 1.58 20 40 0.9 1 X 1-1 /2 35BT3010014 1.80 1.80 1.65 15 30 1.0 f----------+ If----------+ A B ,_ 1-1/4 X 1 X 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1 / 4 X 1-1 /2 35BT3012014 1.88 1.88 1.82 15 30 1.3 ,_ -, __ ,_ 1-1/4x2 35BT3012020 2.10 2.10 1.90 10 20 ·-1.6 1-1/2 X 1-1/4 X 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2 X 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 112 c@us<;f:? Fig. 35CP3 -Straight Coupling with Ribs LISTED -ra--Size Part Number A Packin Weight in in Inner Master lb 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size Part Number A Packing Weight in in Inner Master lb 1 X 1/2 35RC3010004 1.69 80 160 0.3 ---,_ -1 X 3/4 35RC3010006 1.69 60 120 0.4 -~ ,~ ~ 1-1/4 X 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packin Weight B in in Inner Master lb 91A 1 X 1/2 35HB3010004 1.06 180 360 0.2 1 X 3/4 35H 83010006 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2 X 1 35HB3014010 1.25 75 150 0.4 1-1/2 X 1-1/4 35HB3014012 1.25 75 150 0.3 2x1 35H83020010 1.38 40 80 0.6 2 X 1-1/4 35HB3020012 1.38 40 80 0.6 2 X 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug Size Part Number A Packin Weight in in Inner Master lb ~A 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Fig. 35U 3 -Union with Brass Seat Size Part Number A Packing Weight in in Inner Master lb 1 35U 3010 2.19 20 40 1.0 ,~ -,_ ---,,~ ~ ,_ 1-1/4 35U 3012 2.50 15 30 1.2 -,----·--1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com c®us~ Fig. 35X 3 -Cross LISTED Size Part Number A Packina Weight in in Inner Master lb 1 35X 3010 1.50 20 40 0.9 --,_ --1-1/4 35X 3012 ~ ,_ 1.75 ~ ,~ 12 24 -~ 1.4 ,~ -,_ 1-1/2 35X 3014 1.94 8 16 1.8 -,~ ~ ,~ 2 35X 3020 2.25 6 12 2.8 Fig. 35RX3 -Reducing Cross Size Part Number A B Packina Weight in in in Inner Master lb 1-1/4x1 35RX3012010 1.67 1.58 15 30 1.2 1--,,-1-1/2 X 1 35RX3014010 _,_ 1.80 1.65 12 ~,~ 24 1.4 ,_ 2 X 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3 -Cap 9} Size Part Number A Packin Weight in in Inner Master lb 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 0.1 1 35C 3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3 -Beam Clamp Size Part Number A Packino Weight in in Inner Master lb 3/8 35BC3003 0.75 100 200 0.3 -,_ 1/2 35BC3004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 114 SAMMYS® FOR WOOD SAMMYS® FOR WOOD -Vertical Application Application Product Features #14 Black Nut Driver Part# 8113910 #14 SW Red Nut Dnver Part# 8114910 •-HA Not less than 2" nominal width ~ Not less than 3" nominal thickness (2-1/2") (depth or side f vertical member) Wood Flooring Composite I Truss Consult truss manufacturer for recommended 1nstallat1on point ·Pre-dr11/mg may be reqwred for GST 25-380 Tool avat!able on page 11 • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Watch a video demonstration at www.itwbuildex.com A I Rod Part M d I Screw Ultimate UL Test FM Test Box Case pprova s Size Number O e Descriptions Pullout (lbs) Load (lbs) Load (lbs) Qty Qty VERTICAL MOUNT 1/4" 8002957 GST 100 1/4 X 1" 210 (7/16" OSB) 25 125 670 (3/4" Ply) 1/4" 8003957 GST 200 1/4 x2" 1760 (Fir) 25 125 ®. 3/8" 8007957 GST10 1/4 X 1" 210 (7/16" OSB) 300 25 125 670 (3/4" Ply) UL ... 3/8" 8008957 GST20 1/4 X 2" 1760 (Fir) 850 1475 25 125 ~-3/8" 8068925 GST 20-SS 1/4 X 2" 1760 (Fir) 850 25 125 ® 3/8" 8009925 GST 25-380 3/8 X 2-1/2" 2113 (Fir) 1500 25 125 ®. FM • 3/8" 8010957 GST30 1/4 X 3" 2060 (Fir) 1500 1475 25 125 3/8" 8069925 GST30-SS 1/4 X 3" 2060 (Fir) 25 125 1/2" 8013925 GST2 1/4 x2" 1760 (Fir) 25 125 1/2" 8015925 GST3 1/4x3" 2275 (Fir) 25 125 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. For the most up to date information. visit www.itwbuildex.com I SIDEWINDER® FOR WOOD -Horizontal Application #14SWR.{ Nut Driver Part# 8114910 Application Product Features Not less than 2· nominal width (1-1/2"} up to 3-1/2" pipe; not less than 3" (2-1/2"} nominal width 4" & 5" pipe +-----+ Minimum 2-1 /2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2· or thicker nailing strips resting on top of steel beams. )" Floor Joist • No pre-drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. Watch a video demonstration at www.itwbuildex.com A I Rod Part M d I Screw Ultimate UL Test Box Case pprova s Size Number O e Descriptions Pullout (lbs) Load (lbs) Qty Qty HORIZONTAL MOUNT 1/4" 8019957 SWG 200 1/4 x2" 1725 (Fir) 25 125 ® 3/8" 8020957 SWG10 1/4 X 1" 622 (Fir) 300 25 125 @. .. 3/8" 8021957 SWG20 1/4 x2" 1725 (Fir) 1050 25 125 (5.) 3/8" 8073925 SWG 20-SS 1/4 x2" 1725 (Fir) 850 25 125 ~ 3/8"* 8022925 SWG 25-380 3/8 X 2-1/2" 2249 (Fir) 1500 25 125 3/8" 8023925 SWG30 1/4 X 3" 1884 (Fir) 25 125 • May require pre-drilling; consult joist manufacturer. SAMMYS SWIVEL HEAD™ FOR WOOD -Swivel Application #14 Black Nut Driver Part# 8113910 #14 SH Orange Nut Dnver Part# 8273910 Application Product Features • Eliminates distortion of threaded rod. • Accommodates up to 3 ½" x 12 pitch roof. • Allows 17° deflection from vertical. • Saves time from traditional methods. • Reduces installation costs. • Manufactured in the U.S.A. A I Rod Part M d I Screw Ultimate UL Test Load FM Test Min Box Case pprova s Size Number O e Descriptions Pullout (lbs) (lbs) Load (lbs) Thickness Qty Qty SWIVEL MOUNT 3/8" 8139957 SH-GST20 1/4x 2" 1257 (Fir) 1050 1475 25 125 @ 3/8"* 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1903 Dim. lumber 1500 1406@45°off vertical 850@45° 25 125 Dim. Lumber 903 Dim. Lumber 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406@45°off vertical 25 125 Dim. Lumber • May require pre-drilling; consult joist manufacturer. ACCESSORIES SAMMYS TOGGLEM #14Black { Nut Driver Part# 8113910 Application Installation Steps '\ Pre-Cast Hollow Core Concrete 1. Pre-drill a 5/8" hole with a regular drill or hole saw. 2. Insert SST screw into #14 black nut driver. With wing nut and washer on bolt, insert wing nut through surface, and begin installation. 3. When bolt is secure and nut driver spins free, stop drill motor and remove. 4. SST screw is now ready to receive 1/4", 3/8", or Metric all thread rod or bolt stock. Rod Size Part Number Model Screw Descriptions Ultimate Pullout (lbs) Box Qty Case Qty 1/4" 8063925 SST 300 1/4 X 3" 3/8" 8064925 SST30 1/4 X 3" 450 (Lath & Plaster) 404 (2 Layers 5/8 Rock) 450 (Lath & Plaster) 404 (2 Layers 5/8 Rock) 25 125 25 125 CEILING SCREWS { CWIT Installation Tool Part# 8110910 Application Product Features Use the Speedy Pole Toor for easy installation of ceiling screws without ladders or scaffolding! (see pg 13 for details) • 3/16" eyelet to accommodate common wire size. • ICC approvals can be found at www.itwbuildex.com under Evaluation Report# ER-5367. Part . . . Overal Total Ultimate Max ICC Test Box Case Approvals Substrate Number Model Point Description Length Pullout (lbs) Gauge Load (lbs) Qty Qty ICC STEEL 8107957 CWSD 1* Teks 1/4 X 1" 2" 472 (20 ga) 16ga. 170 (20 ga.) 25 125 ICC STEEL 8190957 CWSD 15* Gimlet 1/4 X 1-1/2" 2-3/4" 472 (20 ga) 20 ga. 170 (20 ga.) 25 125 WOOD Teks 1393 (Fir) ICC STEEL 8108957 CWSD2* Teks 1/4 x2" 3-1/4" 472 (20 ga) 16 ga. 170 (20 ga.) 25 125 ICC 8110910 CWIT Installation Tool • Does not comply with ROHS requirements DEKTITE® PIPE FLASHING Application Product Features re STAY UP TO CODE! its. • Complies with NFPA 13 Code Changes. • Flashing for dry pendant sprinklers subject to extreme temperature changes. • One piece construction is easy to install. • Pipe diameter markings ensure accurate fit. • EPDM temperature range of -65°F to +250°F. Part Number Description Pipe Outside Diameter Dektite Base Diameter Dektite Height Box Qty 4001910 4003910 4004910 Mini 1 2 1/4"-1-1/8" 1/4" -2" 1-3/4" -3-1/4" 3-1/2" 4-3/4" 6-1/4" 1-3/4" 3" 4" SPEEDY POLE TOOLTM & UNIVERSAL SOCKET KIT Universal Pole Tool Socket Kit (8129910) Includes: Product Features • Adaptor Plug (a) • Socket Driver for SAMMYS (b) • Socket Driver for Ceiling Wire Screws (c) • Socket Driver for 1/4" Standard Nut Drivers (d) • Stud Plug for Viper or Ladd Powder Actuated Attachment (e) (Items not sold seperate/y) E Watch a video demonstration at ... : www.itwbuildex.com • The Pole Tool and Universal Socket Kit provide easy and safe installation for: -Sammys -Jack Chain -Threaded Rod -Wire -Pencil Rod -Screws -Ceiling Screws • Ideal for retrofit and hard-to-reach projects in wood and steel. Part Number Description Box Qty 8123910 8124910 8125910 8126910 8127910 8128910 8129910 Pole Tool 6' (3' -6') Pole Tool 12' (4' -12') Pole Tool 18' (6' -18') Pole Tool 24' (8' -24') Sammys Socket Driver Ceiling Wire Socket Driver for wire and chain Universal Pole Tool Socket Kit Product Features • 1/2", 3/4", and 1" threading • Magnetic strip for ease of use • Pocket Sized • Lightweight 20 10 10 • 3-vial design for measurement of 0°, 45°, and 90° angles APPROVALS 8020957 SWG 10 8008957 GST20 8068925 GST20-SS 8010957 GST30 8009925 GST25-380 8022925 SWG 25-380 8021957 SWG20 8073925 SWG 20-SS 8269957 SH-GST/CST 20 8269957 SH-GST/CST 20 8139957 SH-GST 20 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Horizontal Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal 45° Angle off Vertical 45° Angle off Vertical 17° Angle off Vertical CPVC 1-1/2" 300 2-1/2" 850 2-1/2" 850 4" 1500 4" 1500 3-1/2"-4"* 1500 2-1/2" -3"** 1050 2-1/2" 850 2-1/2" 850 4" 1500 3" 1050 1-1/2" 1-1/2" 4" 1-1/2" 1-1/2" 4" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 4" 1475 1475 1475 1-1/2" 1-1/2" 1-1/2" SAMMYS FOR STEEL -PIPE HANGER Min Steel Thick Max Steel Thick 8038957 DSTR 1 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK50 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWOR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWOR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 3/8" 17° Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK 50 3/8" Vertical 2-1/2" 850 70° Angle off Vertical 4" 1500 8150922 XP20 3/8" Vertical 2-1/2" 850 .027" 2" 940 .029" 4" 1475 .105" 8153922 XP35 3/8" Vertical 4" 1500 .060" 2" 940 .029" 4" 1475 .125" 8294922 SXP20 3/8" Vertical or up to 45° 2" 750 .027" 2" 635 .029" 8295922 SXP35 3/8" Vertical or up to 89° 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP35 3/8" Horizontal 3-1/2" 1250 .060" SAMMYS FOR CONCRETE· PIPE HANGER 8059957 CST20 3/8" Vertical 4" 1475 3000 8061957 SWC20 3/8" Horizontal 4" 1475 3000 8150922 XP20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC :s; 35 PCF (lbs/ft3) Part Rod Mount UL Load UL Min Steel Number Model Size Direction Rating (lbs) Thickness SAMMYS FOR STEEL -LUMINAIRE FITTING 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 3/8" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SXP20 3/8" Vertical 170 .027" 45° 80 .027" 8295922 SXP35 3/8" Vertical 250 .060" goo 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" Part Rod Mount UL Load UL Min. Steel . Number Model Size Direction Rating (lbs) Thickness LiSted Application SAMMYS FOR STEEL -CONDUIT, TUBING, AND CABLE 8150922 XP20 3/8" Vertical 8153922 XP35 3/8" Vertical 8294922 SXP20 3/8" Vertical 8295922 SXP35 3/8" Vertical 8293957 SWXP35 3/8" Horizontal 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod Sheet Steel Gauges Gauge No._ 22 ga. 20 ga. Nominal Decimal Equivalent .030" .036" 283 500 283 500 500 18 ga. .048" .027" .060" .027" .060" .060" 16 ga. .060" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit UL Listed 4S16 -Cable Hanger, Cat. No. C-Z2000 Plenum Rated, 14 ga. .075" Complies w/ NEC Standards 12 ga. .105" 118" .125" 3/16" .188" 1/4" .250" 1 *SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" *SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4' ••swG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" **SWG 20 Maximum i e size in wood timber or ·oist allowed b UL is 3' UL compliance with NEC Standards. UL and FM tests were performed in compliance with NFPA 13 Standards. Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-purlin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030") or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory Environments For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST20 .182" 1/8" GST 25-380 .280" 7/32" SWG20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings/ FM Approvals UL and FM reports are available at www.itwbuildex.com @us ~ Pl'EHANGER Ai.SO L&TED AS CONDUlf AND CABLE HARDWARE Al.SO Ll6TEDASANCHORFORLUIINAIRE 9R21 Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Manufactured in the U.S.A. Products Contact Information MANUFACTURED U.S.A Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 (!)TOLC□· Fig. 25 -Surge Restrainer Size Range -One size fits 3/4" thru 2" pipe Material -Pre-Galvanized Steel Function -Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals -Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish -Pre-Galvanized Order By -Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344, 108 .,,..,---......... ,/-· --......... / " / ( \ "-.. c@us LISTED COOPER 8-LINE 1375 Sampson Ave• Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 ,,,, COOPER B-Line TQLC□· www.tolco.com --------- J l' _.:' U ,)t NIBc□· Revision 8/15/2005 Fig. 98 -Rod Stiffener Size Range -Secures 3/8" thru 7/8" hanger rod Material -Carbon Steel Function -Secures channel to hanger rod for vertical seismic bracing. Approvals -Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish -Electro Galvanized Note -Available in HOG finish or Stainless Steel materials. Order By -Figure number Fig. 99 -All Thread Rod Cut to Length Size Range -Secures 3/8" thru 7/8" rod in 1" increments Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -Figure number, rod diameter, rod length and finish Fig. 100 -All Thread Rod Full Lengths Size Range -Secures 3/8" thru 7/8" rod in 1 O' lengths Material -Carbon Steel Maximum Temperature -750°F Finish -Plain Note -Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By -Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 4960 4420 222 1¼ 8000 7140 360 1½ 11630 10370 510 Component of State of ® California OSHPD Approved c l LISTED Seismic Restraints System Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 3/8 1/2 5/8 3/4 7/8 650°F 750°F 610 1130 1810 2710 3770 540 1010 1610 2420 3360 ■ OFFICE/MANUFACTURING FACILITY· 1375 SAMPSON AVE.· CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE• 800.786.5266 www.tolco.com Pipe Hangers Fig. 200 -"Trimline" Adjustable Band Hanger {Cooper B-Line Fig. B3170NF) Fig. 200F -"Trimline" Adjustable Band Hanger with Felt Lining {Cooper B-Line Fig. B3170NFF) Fig. 200C -"Trimline" Adjustable Band Hanger with Plastic Coated {Cooper B-Line Fig. B3170NFC) Fig. 200S -"Trimline" Adjustable Band Hanger with Non-Captured Nut c□- c@us LISTED 12 Size Range: Fig. 200 -1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: • (1/2'' (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. • (21 /2'' (65mm) thru 8" {200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1 /2'' {15mm) thru 8" {200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F {343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM OS 2-0. Pipe Size Rod Size Part No. in. (mm) 200-1/2 1/2'' (15) 3/s"-16 200-3/4 3/4" (20) 3/s"-16 200-1 1" (25) 3/s"-16 200-11/4 11/4" (32) 3/s"-16 200-11/2 11/2'' (40) 3/a"-16 200-2 2" (50) 3/a"-16 200-21/2 211211 (65) 3/s"-16 200-3 3" (75) 3/a"-16 200-31/2 31/2'' (90) 3/s"-16 200-4 4" (100) 3/s"-16 200-5 5" (125) 1/2''-13 200-6 6" (150) 1/2''-13 200-8 8" (200) 1/2''-13 Fig. 200C A in. (mm) in. 31/s'' (79.4) 25/g" 31/a" (79.4) 211211 33/s'' (85.7) 25/a" 33/4" (94.0) 27/a" 37/a" (98.4) 27/a" 41/2'' (114.3) 3" 55/s" (142.9) 41/s" 57/s" (149.1) 4" 73/s" (187.3) 51/411 73/s" (187.3) 5" 91/a" (231.8) 61/4'' 101/8'' (257.2) 63/4" 131/s" (333.4) 83/411 B (mm) (66.7) (63.5) (66.7) (73.0) (73.0) (76.3) (104.7) (101.6) (133.3) (127.0) (158.7) (171.4) (222.2) Fig. 200-1 to 200-2 Fig. 200F Approx. Wt./100 lbs. (kg) 11 (5.0) 11 (5.0) 12 (5.5) 13 (5.9) 14 (6.4) 15 (6.9) 27 (12.3) 29 (13.3) 34 (15.6) 35 (16.0) 66 (30.2) 73 (33.4) 136 (62.3) B A Fig. 200-1/2. 200-3/4 Fig. 200-21/2 to 200-8 Fig. 200 Fig. 200S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. · Pipe Hangers Fig. 200M -"Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 -1 /2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: • (1/2" (15mm) thru 2" (50mm)} Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21 /2'' (65mm) thru 8" (200mm)} Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2'' (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM OS 2-0. Pipe Size Rod Size Part No. in. (mm) in. 200M8-1/2 1/2'' (15) MB 31/all 200M10-1/2 1/2'' (15) M10 31/all 200M8-3/4 3/4" (20) MB 31/all 200M10-3/4 3/4" (20) M10 31/sll 200M8-1 111 (25) MB 33/a'' 200M10-1 111 (25) M10 33/all 200M8-11/4 11/411 (32) MB 33/411 200M10-11/4 11/4'' (32) M10 -33/411 200M8-11/2 11/2'' (40) MB 37/a" 200M10-11 /2 11/2'' (40) M10 37/s" 200M8-2 211 (50) MB 41/2'' 200M10-2 2" (50) M10 41/2'' 200M-21/2 21/2'' (65) M10 55/a" 200M-3 3" (75) M10 57/a" 200M-31/2 31/2'' (90) M10 73/a" 200M-4 4" (100) M10 73/a" 200M-5 5" (125) M12 91/8" 200M-6 6" (150) M12 101/s" 200M-8 8" (200) M12 131/a'' A (mm) (79.4) (79.4) (79.4) (79.4) (85.7) (85.7) (94.0) (94.0) (98.4) (98.4) (114.3) (114.3) (142.9) (149.1) (187.3) (187.3) (231.8) (257.2) (333.4) in. 25/all 25/811 21/2'' 21/2'' 25/a" 25/811 27/a" 27/811 27/s" 27/a" 3" 3" 41/a" 411 51/411 5" 61/411 63/411 83/411 Fig. 200-1 to 200-2 B Approx. Wt./100 (mm) lbs. (kg) (66.7) 11 (5.0) (66.7) 11 (5.0) (63.5) 11 (5.0) (63.5) 11 (5.0) (66.7) 12 (5.5) (66.7) 12 (5.5) (73.0) 13 (5.9) (73.0) 13 (5.9) (73.0) 14 (6.4) (73.0) 14 (6.4) (76.3) 15 (6.9) (76.3) 15 (6.9) (104.7) 27 (12.3) (101.6) 29 (13.3) (133.3) 34 (15.6) (127.0) 35 (16.0) (158.7) 66 (30.2) (171.4) 73 (33.4) (222.2) 136 (62.3) B A TO CO c®us umn ~ Fig. 200-1/2. 200-3/4 Fig. 200-21 /2 to 200-8 All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers Fig. 200H -Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (100mm) trapeze pipe size. Material: Steel -Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with 3/s"-16 or 1/2"-13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C} Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. Pipe Size Rod Size A Part No. in. (mm) in. (mm) in. 200H-2-3/s 2" (50) 3/a''-16 49/1611 (115.9) 37/32'1 200H-2-1/2 2" (50) 1/2''-13 423/32" (119.8) 33/a" 200H-21f2.3/a 21/2'' (65) 3/a"-16 55/16 11 (134.9) 323/3211 200H-21 /2-1 /2 21/2'' (65) 1/2''-13 515/3211 (138.9) 37/a" 200H-3-3/a 3" (75) 3/a"-16 53/411 (146.0) 327!32'' 200H-3-1f2 3" (75) 1/2''-13 57/a" (148.1) 331/3211 200H-4-3/s 4" (100) 3/s"-16 67/s" {174.6) 47/16" 200H-4-1/2 4" (100) 1/2''-13 71/32'' (178.6) 419!32" B A B Approx. Wt./100 (mm) lbs. (kg) (81.7) 48 (21.8) (85.7) 45 (20.4) (94.4) 59 (26.7) (98.3) 56 (25.4) (97.6) 63 (28.6) {100.8) 60 (27.2) (112.7) 76 (34.5) (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. ®TD c□- c@us USTED All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F. LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data • Water dispersible • Applies equally well to wet or dry surfaces • Suitable for all types of pipe lines, including potable water • Excellent working range -10° to 150° • Will not support bacteria • Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe • FGG/BM/CZ™ System Compatible Program* • Certified to NSF/ANS/Std 61-G Fee SYSTEII COMPATIBLE *FBC™ System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX+ 1 800 344-3775 Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. •• © 2012 Fire Protection Products, Inc. FPPI®, LubeFit® are registered trademarks of Fire Protection Products, Inc. ~ ~ FGG/BMICZ™, Blaze-Master®, FlowGuard Got~ and Corzan® are registered trademarks of Noveon IP Holdings Corp. ~ '" U.s.A. F P P I® Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 2Ib (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. Fee SYSTEM COMPATIBLE *FBC™ System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. © 2012 Fire Protection Products, Inc. FPPI®, LubeFit® are registered trademarks of Fire Protection Products, Inc. FBC™, BlazeMaster®, FlowGuard GolcP and Corzan® are registered trademarks of Noveon IP Holdings Corp. •• ~ ... ~ MAD■IN U.s.A. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Features • Heavy Duty Cutting Oil • Excellent Tool Life • Chlorine Free • All types of ferrous metal or pipe • Improved Surface Finish • Low Odor • Low Smoke FBC SYSTEM COMPATIBLE *FBCT" System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. •• © 2013 Fire Protection Products, Inc. FPPI®, Thread Rt® are registered trademarks of Fire Protection Products, Inc. ., ~ ....... --._.....,_..., .a.._ ........ ...-s.f-~ Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hotline. They may be reached at 1 800 424-9300 .