HomeMy WebLinkAbout5051 AVENIDA ENCINAS; ; FPC2021-0229; PermitPERMIT REPORT Fire Permit Print Date: 02/25/2022 Job Address: Permit Type: Parcel#: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: 5051 AVENIDA ENCINAS, CARLSBAD, CA 92008-4363 FIRE-Construction Commercial Work Class: 2100904300 Track#: $566,579.00 Lot#: Project#: Plan#: Construction Type: Orig. Plan Check#: Plan Check#: Fire Alarm (city of Carlsbad Permit No: FPC2021-0229 Status: Closed -Finaled Applied: 12/01/2021 Issued: 12/10/2021 Finaled Close Out: 02/25/2022 Inspector: Final Inspection: Description: PREVOST -INSTALL NEW ALARM SYSTEM WITH 19 SMOKE DETECTORS, 1 HORN/STROBE, 1 PULL STATION, & AN ANNUNCIAT< (ADDRESSABLE) Applicant: LOW VOLTAGE INTEGRATED SYSTEMS KYLE ARGUIJO 1090 JOSHUA WAY, #STEA VISTA, CA 92081-7800 (760) 598-4110 FEE FIRE New Alarm System Total Fees: $1,392.00 Fire Department Total Payments To Date: $1,392.00 FPContractor: LOW VOLTAGE FIRE INC 1090 JOSHUA WAY, # UNIT A VISTA, CA 92081-7800 (760) 598-4110 Balance Due: 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-4665 I 760-602-8561 f I www.carlsbadca.gov AMOUNT $1,392.00 $0.00 Page 1 of 1 FIRE ALARM SYSTEM SUBMITTAL •• •.............- Lc.>wV"'c.>l#'Cllge integ r a-ted systems FIRE ALARM • SOUND • DA TA e MEDIA• SECURITY• CCTV• ACCESS CONTROL SUBMITTAL PREVOST CONSTRUCTION 5051 Avenida Encinitas. Carlsbad CA 92008 LOW VOLT AGE INTEGRATED SYSTEMS, INC. 1090 Joshua Way Ste A VISTA, CA 92081 (760) 598-4110 Phone (760) 598-4107 Fax info@sdlvis.com License: ClO, C16 # 791832 PHONE: (760) 598-4110 FAX: (760) 598-4107 Lc,wVol,.~ge i ntegro tod $y$toms MATERIAL LIST PART NFW-50X SLE-CDMA-FI RE N-ANN-80 P2WL FSP-951 NBG-12LX - DESCRIPTION MANUFACTURER FIRE ALARM CONTROL PANEL NOTIFIER CELL DIALER NAPCO ANNUNCIATOR NOTIFIER HORN/STROBE @ WALL SYSTEM SENSOR SMOKE DETECTOR NOTIFIER PULL STATION NOTIFIER FA DISCLOSURE LETTER - Low Voltage Integrated Systems, Inc. 1090 Joshua Way, Ste A • Vista, California 92081 FIRE• SECURITY• CCTV• ACCESS CONTROL • SOUND• MEDIA LICENSE NO. C10, C16 #791832 email: info@sdlvis.com @})NOTIFIER® by Honeywell NFW-50X Intelligent Addressable FACP with Communicator General The FireWarden-S0X (NFW-S0X) is the latest intelligent address- able fire alarm control panel (FACP) within the FireWarden Series and is a direct replacement for the FireWarden-50 (NFW-50). The NFW-50X comes with a pre-installed communicator and supports up to 50 addressable devices in any combination of detectors or mod- ules. With an extensive list of powerful features, the NFW-50X pro- grams just like FireWarden-100 products, yet fits into applications previously served only by conventional panels. The pre-installed !POTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the !POTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTM). Features • Listed to UL Standard 864, 10th edition • Pre-installed !POTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator • Optional CELL-MOD or CELL-CAB-N GSM Central Station Com- municator over AlarmNet® • Compatible with SWIFT® wireless devices • Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address • Two independently programmable, built-in Style Z (Class A) or Style Y (Class B) NAC circuits • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices • Notification Appliance Circuit End of Line resistor matching • Four programmable function keys for ease of maintenance • Two programmable relays and one fixed trouble relay • Built-in Programmer • Integral SO-character LCD display with backlighting • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity • Addressable sounder base • Control module delay timer • Automatic detector sensitivity testing (NFPA 72 compliant) • Automatic device type-code verification • Point trouble identification • Waterflow selection per module point • Alarm verification selection per detector point • Maintenance alert warns when smoke detector dust accumula- tion is excessive • One-person audible or silent walktest with walktest log & printout • System alarm verification selection per detector point • PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) • Up to 16 ANN-BUS annunciators-8 per each ANN-Bus Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator • Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP • Supports FlashScan® and CLIP protocols • SLC operates up to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wire • Single addressable SLC loop which meets NFPA Class B and Class A requirements • 50 addressable device capacity (any combination of addressable detectors and modules) • Compatible with NOTIFIER FireWarden & ONYX Series address- able devices (refer to the FireWarden SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NACS) • Two independently programmable output circuits. Circuits can be configured for the following outputs: -Style Y (Class B) -Style Z (Class A) • Silence Inhibit and Autosilence timer options • Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability • Selectable strobe synchronization per NAC • 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAG circuits and the ANN-BUS is 2. 7 A PROGRAMMING AND SOFTWARE • Autoprogramming (learn mode) reduces installation time • Custom English labels (per point) may be manually entered or selected from an internal library file • Two programmable Form-C relay outputs • 50 software zones • Continuous fire protection during online programming DN-60955:C • 7/16/2018 -Page 1 of 4 • • Program Check automatically catches common errors not linked to any zone or input point • OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.notifier.com. User interface LED INDICATORS • Fire Alarm (red) • AC Power (green) • Trouble (yellow) • Battery fault (yellow) • CO Alarm (red) • Supervisory (yellow) • Ground fault (yellow) • Disabled (yellow) • Maintenance (yellow) • Communication (yellow) • Alarm Silenced (yellow) • F1-F4 Programmable Function Keys (yellow) KEYPAD • 16 key alpha-numeric pad • Acknowledge • Alarm Silence • Drill (Manual Evacuate) • Four (4) programmable function keys • Reset (lamp test) Product Line Information NFW-50X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre-installed IPOTS- COM communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.notifier.com. CELL-CAB-N/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the NFW-50XR (red). DP-ES-B: Optional dress panel for NFW-50X (black). TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For red, order TR-CE.) BB-XP: Optional cabinet for one or two modules. BB-25: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries & CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-25 cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75AH. CHG-120: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTM Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. COMPATIBLE ANNUNCIATORS N-ANN-80: Remote, black LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un- shielded. N-ANN-100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. (Basic model is black; Page 2 of 4 -DN-60955:C • 7/16/2018 order R for red.) N-ANN-I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DN-7105.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242.) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242.) N-ANN-RL Y: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DN-7107.) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) ADDRESSABLE DEVICES FSP-951: Addressable low-profile photoelectric smoke detector. FlashScan only. FSP-951-IV: Addressable low-profile photoelectric smoke detector. Ivory. FlashScan and CLIP mode. NP-200: Addressable low-profile photoelectric smoke detector. 8300-6 base included, FlashScan only. NP-200-IV: Addressable low-profile photoelectric smoke detector. Ivory, 8300-6-IV base included. FlashScan and CLIP mode. FSP-951 T: Addressable low-profile photoelectric smoke detector with thermal sensor. FlashScan only. FSP-951 T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. FlashScan and CLIP mode. NP-200T: Addressable low-profile photoelectric smoke detector with thermal sensor. 8300-6 base included. FlashScan only. NP-200T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory, 8300-6-IV base included. FlashScan and CLIP mode. FSP-951 R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. FSP-951 R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. FlashScan and CLIP mode. NP-200R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. NP-200R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory, FlashS- can and CLIP mode. FST-951: Low-profile 135°F fixed thermal sensor. FlashScan only. FST-951-IV: Low-profile 135°F fixed thermal sensor. Ivory. FlashS- can and CLIP mode. NH-200: Low-profile 135°F fixed thermal sensor. 8300-6 base included, FlashScan only. NH-200-IV: Low-profile 135°F fixed thermal sensor. Ivory. 8300-6-IV base included, FlashScan and CLIP mode. FST-951 R: Low-profile, intelligent, rate-of-rise thermal sensor. FlashScan only. FST-951 R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. FlashScan and CLIP mode. NH-200R: Low-profile 135°F fixed thermal sensor. 8300-6 base included, FlashScan only. NH-200R-IV: Low-profile 135°F fixed thermal sensor. Ivory. 8300-6- IV base included, FlashScan and CLIP mode. FST-951 H: Low-profile intelligent 190°F/88°C fixed thermal sensor. FlashScan only. FST-951 H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. FlashScan and CLIP mode. NH-200H: Low-profile intelligent 190°F/88°C fixed thermal sensor. 8300-6 base included, FlashScan only. ' NH-200H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. 8300-6-IV base included, FlashScan and CLIP mode. Legacy Devices FSP-851: Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. FSP-851T: Addressable low-profile photoelectric smoke detector with thermal sensor. NP-1 00T: Addressable low-profile photoelectric smoke detector with thermal sensor. FSP-851 R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. NP-1 00R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FST-851: Fast-response, low-profile heat detector. NH-100: Fast-response, low-profile heat detector. FST-851 R: Fast-response, low-profile heat detector with rate-of-rise option. NH-1 00R: Fast-response, low-profile heat detector with rate-of-rise option. FST-851H: Fast-response, low-profile heat detector that activates at 190°F/88°C. NH-100H: Fast-response, low-profile heat detector that activates at 190°F/88°C. FAPT-851: Addressable low-profile multi-sensor detector. NP-A 100: Addressable low-profile multi-sensor detector. 82005: Programmable, addressable sounder base. B2005R: Addressable sounder base. DNR: lnnovairFlex low-flow non-relay duct-detector housing. (Order FSP-851 R, FSP-951 R, or NP-1 00R separately.) DNRW: lnnovairFlex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order FSP-851 R, FSP-951 R, or NP-1 00R separately.) Addressable Modules FMM-1: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NMM-100: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. FDM-1: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NDM-100: Dual Monitor Module. Same as NMM-100 except it pro- vides two Style B (Class B) only IDCs. FMM-101 : Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. FZM-1: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. NZM-100: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. FCM-1: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires extemal 24 VDC to power notification appliances. FRM-1: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NC-1 00R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NBG-12LX: Addressable manual pull station with interface module mounted inside. NOT-BG12LX: Addressable manual pull station with interface mod- ule mounted inside. I5O-X: Fault Isolator Module. N100-ISO: Fault Isolator Module. ISO-6: Six-fault isolator module. Mount one or two modules in a 88- XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SMB500: Used to mount all modules except FMM-101/NMM-100P. NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NZM-100-6: Six-zone interface module. Mount one or two modules in a 88-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SWIFT Wireless Devices FWSG: Wireless Gateway FWD-200P: intelligent, wireless photo detector. FWH-200ROR135: LiteSpeed intelligent wireless rate of rise (135°) heat detector. FWD-200ACCLIMATE: Wireless Acclimate Detector FWH-200FIX135: intelligent wireless fixed-temperature (135°) heat detector. FW-MM: Intelligent wireless monitor module. FW-RM: Intelligent wireless relay module. NBG-12LW: Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: lntelligentAV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com . NOTE: For more information on Compatible Addressable Devices for use with the FireWarden-50X, see the following data sheets (document numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), N100-ISO (DN-6994), NP-100 series (DN-6995), NH-100/NH-100R (DN-6997), DNR/lnnovairFlex (DN-60424, DN-60429), NP-A 100 (DN-6998), NMM-100/NMM-100PINDM-100/NZM-100 (DN-6999), NC-100 (DN-7000), NC-100R (DN-60383), NMM-100-10 (DN-6990), MM-1/FDM-1/FZM-1/FMM-101 (DN-6720), FCM-1/FRM-1 (DN-6724), NOT-BG12L.X (DN-7001), NBG-12L.X (DN-6726), and FireWarden SLC Manual (52304). ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm assembly supervises the FMM-1/NMM-100-10, FDM-1/ NDM-100, FMM-101/NMM-100P, and FCM-1/NC-100 module cir- cuits. The 3.9k ohm assembly supervises the XP6-MA/NZM-100-6 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required , it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. DN-60955:C • 7/16/2018 -Page 3 of 4 S~ECIFICATIONS System Capacity • Intelligent Signaling Line Circuits ................................................ 1 • Addressable device capacity .................................................... 50 • Programmable software zones ................................................. 50 • Annunciators ............................................................................. 16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto-sensing-no switch required. Wire size: minimum 14 AWG (2.00 mm2} with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (FireWarden-50X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for two NACs, Style Y (Class B} or Style Z (Class A}. Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4. 7k ohm, ½ watt (P/N 71252 UL listed) for Style Y (Class B} NAC; system capable of 1.9 kn -22 kn ELR range. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A@ 30 VDC (resistive}, 0.5 A@ 30 VAC (resistive}. Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.} wide x 0.72" (1 .82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR- CE/B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.} Dimensions: 20.00" (50.80 cm.} high x 22.5" (57.15 cm.} wide x 8.5" (21 .59 cm.} deep. ISO 9001 ::.:,t. :~rJ:.;1 QUlllTY SYSHMS Temperature and Humidity Ranges This system meets NFPA requirements for operation at O -49°C/32 -120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°c (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 -27°C/60 - 80°F. NFPA Standards The FireWarden-50X complies with the following NFPA 72 Fire Alarm Systems requirements: -LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). -AUXILIARY (Automatic, Manual and Waterflow} (requires 4XTM). -REMOTE STATION (Automatic, Manual and Waterflow} (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) -PROPRIETARY (Automatic, Manual and Waterflow). -CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). -OT, PSDN (Other Technologies, Packet-switched Data Net- work) -IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). -CBC 2007 (Seismic} Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden-50X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S635 • CSFM: 7165-0028:0505 • FDNY: COA#6268 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. AlarmNet®, NOTIFIER®, Firewarden®, SWIFT®, and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and WindO'NS® are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Country of Origin: USA (G})NOTIFIER® by Honeywell LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 11165-0028:0505 I 7165 --FIRE ALARM CONTROL UNIT (COMMERCIAL) NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 2 Models FireWarden-50X (NFW-50X) and FireWarden-100X *(NFW-100X) Fire Alarm Control Units. Automatic, manual, waterfowl, sprinkler supervisory, local, remote station (PPU), and central station (PPU) services. The FireWarden-50X (NFW-50X) is a compact version of the FireWarden-100X *(NFW-100X). The FireWarden-50X (NFW-50X) has 50 addressable device capability and 2 Notification Appliance Circuits with a 3.0 amps total 24VDC output in Alarm. The FireWarden-100X *(NFW-100X) has 198 addressable device capability and 4 Notification Appliance Circuits with 3.0amps total 24VDC output in Alarm expandable to 6.0amps with Model PWRMOD24. The Model IPOTS-COM provides Phone and IP communication. Models FireWarden-50X (NFW-50X) and FireWarden-100X *(NFW-100X) system components are as follows: IPOTS-COM POTS and IP Communicator 4XTMF Transmitter Module N-ANN-80 Remote Annunciator Module ANN-100 Remote Annunciator Module N-ANN-1/O LED Driver Module N-ANN-S/PG Serial/Parallel Interface Module N-ANN-RLY Form-C Relay Module N-ANN-LED Annunciator Module N-ANN-RLED Annunciator Module CELL-MOD GSM Communicator DP-ES-R Dress Panel Model FireWarden-100X *(NFW-100X) system components are as follows: PWRMOD24 NAC Power Expander Module Refer to the listee's data sheet for additional detailed product description and operational considerations. 120/240Vac 50/60Hz In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. *Rev 09-03-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 Listing No. 7165-0028:0505 Page 2 of 2 MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units, emergency alarm system control units and process management equipment for use with separately listed compatible initiating and indicating devices. Refer to Manufacturers Installation Instruction Manual for details. NOTE: XLF: For Fire Alarm Verification Feature (Delay of fire alarm), the maximum Retard/Reset/Restart period must be adjusted to 30 seconds or less. 7165-0075:0500 *Rev 09-03-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Listing Expires June 30, 2022 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division • Universal full event sole path cellular & dual path cellular &/or IP commercial fire alarm reporting from any panel brand, virtually anywhere • For use as primary or backup communications on all 12V-24V control panels and FACPs that communicate using Contact f D and 4/2 (sl.lch as on legacy panels) . • Reports to any Central Station nationwide, with your choice of cellular h~t\,y.!xks: Verizon Netwe>tk Certified C:C>fy1A or GSM3/fl;G'<>h:AT&t ..... : ... .ii'. UL and NFPA 72 Fire Code-Compliant, the Starlink Series Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal support for any brand 12V to 24V fire alarm control panel, reporting in Contact ID and 4/2. With broadest coverage footprint available in Verizon Network Certified TM CDMA or GSM 3/4G models on the AT&T network, as well as mercantile models, all provide the most economical solution and for-easy, versatile installation . Safeguard Accounts & Reliability. For applications currently .. _ .•• relying ~pon _ gujc~Itdisappearin$ traditional phone lines, < •. · StarLinkwire1esscommuni¢ato~ can,be used for primary or > pac:kup ¢orprnunic~tic>!ns';ahdwillrnot·only$ateguard the fire 1~,;:,;i;it,~f~~;;~:~:;t:· ,,~~~~~:e~i~,:;:;;~i~~~ ~~~\~~;off,~r!~tf,iii!i;::;;=y !;1!11t11?il~i~:nn: ··: · as above, for downloading, extends distance up to 100' · C}.iJ,tliofia: Plug in AC Transformer, 16.SV / 20VA (use is subject compliance) SLE-DLCBL Optional High-Speed Napco Panel Up/download cable ' gftent: 200mA .if<>1'+12V e out Power Supply: .··•·· t V9~t;~(11-1 svoc (power-limited output from listed ·trpt i>!nel) :i fin~ut"Cuft~nt: 71 mA with peak RF transmission current of t•·I ·,200mA. it~i1t;'. El;~rical Ratings for the IN 1 Burg/Fire Input: t>• Input Voltage: 9-1 SVDC f-. Maximum Input Current: Up to 2mA from FACP NAC circuit Electrical Ratings for IN 2 and IN 3: · •• Maximum Loop Voltage: 1 SVDC • Maximum Loop Current: 1.2mA • Electrical Ratings for 3 PGM Outputs: • Open Collector Outputs: Maximum voltage 3V when active; 1 SV maximum when not active • Maximum PGM Sink Current: S0mA mount. • Operating Environment Oto 49° C (32-120°F), up to 93% humidity (non-condensing) .... 12V .. 24V Universal FACP Support, auto-current sensing. Support all brands communicating in Contact ID and 4/2. COMPLIANCES: NFPA 72 Editions: 2013, 2010, 2007; UL 864, 9th Ed., are also rated to support Intrusion/Burglary alarm reports where applicable. StarLink™ and · ©NAPCO, NAPCO SecurityTechnalc:,gie$ Inc. IN~~nACt,NS.S.Cl 333 Bayview Ave., Amityville, NY 11701 USA 1-800-645-9445 • Fax: 1-631-789-9292 www.napcosecurity.com ■ LISTING No. CATEGORY: LISTEE: DESIGN: RATING: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 11300-0992:0144 I 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Napco333 Bayview Avene, Amityville, NY 11701 Contact: David Wagner (631) 842-9400 Fax (631) 842-2726 Email: dwagner@napcosecurity.com Page 1 of 2 Models SLE3/4G-CB, SLE3/4G-CB-TF, SLE3/4G-CFB, SLE3/4G-CFB-PS, SLE-CDMA, SLE-CDMA-FIRE, SLE-GSM-3/4G, SLE-GSM-FIRE, SLECDMA-CB, SLECDMA-CB-TF, SLECDMA-CFB, SLECDMA-CFB-PS, SLE-L TEV-FIRE, SLE-L TEV-8D, SLE-L TEV, SLE-LTEV-CFB-PS, SLE-LTEV-CB-TF, SLE-LTEV-CFB, SLE-LTEV-CB, SLE-L TEA-CFB, SLE-L TEA-CFB-PS and SLE-L TEA-FIRE Sole Path Communicators. Model numbers may be followed by an alpha/numeric suffix for marketing purposes. Models SLECDMAI-CFB-PS, SLE3/4GI-CFB-PS, SLECDMAI-CB-TF, SLE3/4GI-CB-TF, SLECDMAI-CFB, SLE3/4GI-CFB, SLECDMAI-CB, SLE3/4GI-CB, SLE-GSMl-3/4G, SLE-CDMAI, SLE-GSMI-FIRE, SLE-CDMAI-FIRE, SLE-L TEVI-CFBPS, SLE-L TEVI-CFB, SLE-LTEVI-FIRE, SLE-LTEAI-CFBPS, SLE-LTEAI-CFB, SLE-LTEAI-FIRE, *SLE-FNI-CFB-PS, *SLE-FNI-CFB, and *SLE-FNI-FIRE Dual Path Communicators. Model numbers may be followed by an alpha/numeric suffix for marketing purposes. *Dual Path Communicators can also be utilized as a Sole Path Communicator. Refer to listee's data sheet for additional detailed product description and operational considerations. 120 Vac -SLE3/4G-CB, SLE3/4GI-CB-TF, SLE3/4G-CFB-PS, SLE3/4GI-CFB-PS, SLECDMA-CFB-PS, SLECDMAI-CFB-PS, SLECDMA-CB-TF, SLECDMAI-CB-TF, SLE-L TEV-CFB-PS, SLE-L TEV-CB-TF, SLE-L TEVI-CFBPS, SLE-L TEA-CFB-PS, SLE-L TEAI-CFBPS, *SLE-FNI-CFB-PS 10-15 Vdc -SLECDMAI-CB, SLE3/4GI-CB, SLE-GSMl-3/4G, SLE-CDMAI, SLE-LTEV, SLE-L TEV-8D, SLE-L TEV-CB 10-25 Vdc -SLECDMAI-CFB, SLE3/4GI-CFB, SLE-GSMI-FIRE, SLE-CDMAI-FIRE, SLE-L TEV-FIRE, SLE-L TEV-CFB, SLE-L TEVI-FIRE, SLE-L TEA-CFB, SLE-L TEA-FIRE, SLE-L TEAi-FiRE, SLE-L TEAI-CFB, SLE-L TEVI-CFB, *SLE-FNI-CFB, *SLE-FNI-FIRE 11-15 Vdc -SLE3/4G-CB, SLE-CDMA, SLE-GSM-3/4G, SLECDMA-CB 11-25 Vdc -SLE3/4G-CFB, SLECDMA-CFB, SLE-CDMA-FIRE, SLE-GSM-FIRE *Revision 2-8-21 V\N\N This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 INSTALLATION: MARKING: APPROVAL: Listing No. 7300-0992:0144 Page 2 of 2 In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Revision 2-8-21 VV'MJ This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 @)NOTIFIER® by Honeywell N-ANN-80 BO-Character Serial LCD Annunciator General The N-ANN-80 annunciator is a compact, backlit, BO-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The N-ANN- 80 and the FACP communicate over a two-wire serial interface employing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The N-ANN-80 is black; for white order N-ANN-80-W. The N-ANN-80 displays English-language text of system point infor- mation including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels pro- grammed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-80s may be connected to the ANN-Bus of each FACP. Minimal programming is required, which saves time during system commissioning. The N-ANN-80 is compatible with NOTI- FIER FACPs with an ANN-Bus, such as the NFW-50X. Features • Listed to UL Standard 864, 9th Edition • Backlit BO-character LCD display (20 characters x 4 lines) • Mimics all display information from the host panel • Control switches for System Acknowledge, Signal Silence, Drill, and Reset • Control switches can be independently enabled or disabled at the FACP • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure • Keyswitch can be enabled or disabled at the FACP • Enclosure supervised for tamper • System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence • Local sounder can be enabled or disabled at the FACP • N-ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels • Time-and date display field • Surface mount directly to wall or to single, double, or 4" square electrical box • Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting • Can be remotely located up to 6,000 feet (1,800 m) from the panel • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC) • Up to eight N-ANN-80s can be connected on the ANN-Bus Controls and Indicators • AC Power • Alarm • Trouble • Supervisory • Alarm Silenced Specifications • Operating voltage range: 18 voe to 28 voe • Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum Ambient temperature: 32°F to 120°F (0°C to 49°C) • Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F) 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep • For use indoors in a dry location • All connections are power-limited and supervised The ANN-Bus POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- IARY POWER SUPPLY The ANN-Bus can be powered by an auxiliary power supply when the maximum number of ANN-Bus devices exceeds the ANN-Bus power requirements. See the FACP manual for more information. ANN-BUS DEVICE ADDRESSING Each ANN-Bus device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-Bus communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The N-ANN-80 connects to the FACP ANN-Bus communications cir- cuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. DN-7114:D • 3/15/2018 -Page 1 of 2 NOTE: For total worst case current draw on a single ANN-Bus refer to appropriate FACP manual. WIRE REQUIREMENTS: POWER CIRCUIT • 14 to 18AWG (0.75 -2.08 mm2) wire for 24 voe power circuit is acceptable. • All connections are power-limited and supervised. • A maximum of eight N-ANN-80 modules may be connected to this circuit. Ordering Options: N-ANN-80: Black 80 character LCD Annunciator. N-ANN-80-W: White, 80 character LCD Annunciator. ANN-SBS0KIT-B: Black surface mount backbox with angled wedge. ANN-SBS0KIT-W: White surface mount backbox with angled wedge. ISO 9001 ::.:~tt=~ QULITY SYSTEMS Agency Listings and Approvals The listings and approvals below apply to the N-ANN-80. In some cases, certain modules may not be listed by certain approval agen- cies, or listing may be in process. Consult factory for latest listing status. • UL: S635 • FM approved • CSFM: 7120-0028:0240 • MEA: 442-06-E Vol. 2 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER® is a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Country of Origin: USA (ffi}NOTIFIER® by Honeywell LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: XLF: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 11120-0028:0240 I 7120 --ANNUNCIATORS NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models N-ANN-80 and *N-ANN-80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as an annunciator for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. 7120-0075:0211 *Rev 12-11 -14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 -, I ~~SYSTEM C~ SENSOR· Indoor Selectable- Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12-or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING @ LISTED S5512 S4011 <8> APPROVED FM approved except for ALERT models 3057383 I , V 7125-1653:0504 7135-1653:0503 The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS868-02 • 12/01/2017 • Page 3 •J. L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1 ½-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'"' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model ___ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model ___ listed to UL 1971 and UL 464 and shall be approved for fire protective seNice. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature Humidity Range Strobe Flash Rate Nominal Voltage Operating Voltage Range2 Operating Voltage Range (MDL3) Input Terminal Wire Gauge Ceiling-Mount Dimensions (including lens) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) Notes: 32°F to 120°F (0°C to 49°C) 1 O to 93% non-condensing 1 flash per second Regulated 12 voe or regulated 24 DC/FWR1 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) 12 to 18 AWG 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC , and SC products will operate at 12 V nominal only for 15 and 30 ed. AVDS868-02 • 12/01/2017 • Page 2 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8-17.5 Volts 16-33Volts 8-17.5 Volts 16-33Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (mA RMS), Ceiling Horn Strobe, Candela Range {15-1n cd) 8-17.5 Volts 16-33Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High .106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Hom Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 L-Series Dimensions 6.83' diam. (173mm) 2.47" (62.7 mm) -------. 1.37" (34.8 mm) -------. Ceiling-Mount Horn Strobes 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White A0545-00 For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". 6.92' diam. (175.77 mm) r-25' 7 I (64mm) 1 0 / / I Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box Model Description Ceiling Strobes SCRL Strobe, Red SCWL Strobe, White SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White A0546-00 A0531-01 ~~SYSTEM \__~ SENSOR~ 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS868-02 • 12/01/2017 LISTING No. CATEGORY: LISTEE: DESIGN: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 11135-1653:0503 I 7135 --AUDIBLE DEVICES Page 1 of 2 System Sensor, Unincorporated Div of Honeywell lnt'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com System Sensor Indoor 2-wire and *4-wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-B2, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *TR-2 and *TR-2W CeilingTrim Rings: *TRC-2 and *TRC-2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 RATING: INSTALLATION: MARKING: APPROVAL: SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Listing No. 7135-1653:0503 Page 2 of 2 Refer to listee's data sheet for detailed product description and operational considerations. 12 voe regulated and 24 VDC/FWR In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dee This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 @) NOTIFIER® by Honeywell FSP-951 Series Addressable Photoelectric Smoke Detectors The NOTIFIER® FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the FSP-851 Series. A new modern, sleek, con- temporary design and enhanced optical sensing chamber is engi- neered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951 T. The FSP-951 R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan® and CLIP applications as designated. Features SLC LOOP: • Two-wire SLC loop connection • Unit uses base for wiring • Compatible with FlashScan® and CLIP protocol systems • Stable communication technique with noise immunity ADDRESSING: • Addressable by device • Rotary, decimal addressing (Refer to the NOTIFIER panel manuals for device capacity.) ARCHITECTURE: • Sleek, low-profile, stylish design • Unique single-source design to respond quickly and dependably to a broad range of fires • Integral communications and built-in device-type identification • Built-in tamper resistant feature • Remote test feature from the panel • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1 (FlashScan systems only) • Built-in functional test switch activated by external magnet • Removable cover and insect-resistant screen for simple field cleaning • Expanded color options OPERATION: • Designed to meet UL 268 7th Edition • Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level • LED "blinks" when the unit is polled (communicating with the fire panel) and latches in alarm. • Low standby current MECHANICALS: • Sealed against back pressure • SEMS screws for wiring of the separate base • Designed for direct-surface or electrical-box mounting • Plugs into separate base for ease of installation and maintenance • Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: • Optional relay, isolator, and sounder bases Installation FSP-951 Series plug-in intelligent smoke detectors use a detach- able base to simplify installation, service and maintenance. Installa- tion instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B'J wiring only. When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limitations between isolator modules and iso- lator bases. Construction These detectors are constructed of fire-resistant plastic. The FSP- 951 Series plug-in intelligent smoke detectors are designed to com- mercial standards and offer an attractive appearance. Operation Each FSP-951 Series detector uses one of the panel's addresses (total limit is panel dependent) on the NOTIFIER Signaling Line Cir- cuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The FSP-951 Series offers fea- tures and performance that represent the latest in smoke detector technology. DN-60977:B • 7/1/2019 -Page 1 of 3 · Product Line Information NOTE: "-JV' suffix indicates CLIP and FlashScan device. FSP-951: White, low-profile intelligent photoelectric sensor, FlashS- can only FSP-951A: Same as FSP-951 but with ULC listing FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor FSP-951A-IV: Same as FSP-951-IV but with ULC listing FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device, FlashScan only FSP-951TA: Same as FSP-951T but with ULC listing FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed-temperature thermal device FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing FSP-951 R: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW, FlashScan only FSP-951 RA: Same as FSP-951 R but with ULC listing, for use with DNRA FSP-951 R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW FSP-951 RA-IV: Same as FSP-951 R-IV but with ULC listing, for use with DNRA INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981. 8300-6: White, 6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) 8300-6-IV: lvory,6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) BJ00A-6: Same as B300-6, ULC listed B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed 8300-6-BP: Bulk pack of B300-6, package contains 1 0 8501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed (CSFM: 7300-1653:0109) 8501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) 8501-IV: Ivory color, 4" standard European flangeless mounting base. UUULC listed (CSFM: 7300-1653:0109) 8501-WHITE-BP: Bulk pack of B501-WHITE contains 10 8224RB-WH: White, relay base (CSFM: 7300-1653:0216) 8224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) 8224RBA-WH: White, relay base, ULC listing 8224RBA-IV: Ivory, relay base, ULC listing 82248I-WH: White, isolator detector base (CSFM: 7300-1653:0216) 82248I-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224BIA-WH: White, isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base, ULC listing 8200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) 8200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing Page 2 of 3-DN-60977:B • 7/1/2019 8200SA-IV: Same as B200S-IV, ULC listing B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing 8200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) 8200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) 8200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) 8200SRA-WH: Same as B200SR-WH with, ULC listing 8200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. ( CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21 0LP(A) base TR300-IV: Ivory, replacement flange for B21 0LP(A) base RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B300-6(A). M02-04-00: Test magnet M02-09-00: Test magnet with telescoping handle CK300: Color Kit (includes cover and trim ring), white, 10-pack CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack .. . . -SPECIFICATIONS Sensitivity: Listings and Approvals • UL Applications: 0.5% to 4.0% per foot obscuration. • ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0" (5.3 cm) high; base determines diameter -B300-6: 6.1 " (15.6 cm) diameter Listings and approvals below apply to the FSP-951 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. -B501: 4" (10.2 cm) diameter • UL/ULC Listing: S1115 • FM Approved For a complete list of detector bases see DN-60981 • CSFM: 7272-0028:0503 Shipping weight: 3.4 oz. (95 g) Operating temperature range: • FSP-951 : 32°F to 122°F (0°C to 50°C) • FSP-951 T Series: 32°F to 100°F(0°C to 38°C) • FSP-951 R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% -93% non-condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 -32 volts DC peak Standby current (max. avg.): 200µA@ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA@ 24 voe ("ON") DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is avail- able at www.systemsensor.com. NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.71 61 www.notifier.com ISO 9001 ::r.:1~'. ;~tJA'.:l QUlllTY SYSTIMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ri(ii)tiScar;® NOTIFIER®. an:l Syi>t8rn ~;o)[):c,Gr-ft, ;lfo) ,qi~t0r,~(j tW•l(·;nla!~S :,f Hcnerwell lnt0ntit,ord inc.. U2U1;} l)y Hcn::,i,,wel! lr:fe,naticnal inc. N ngrns reser,ed UntJtJtt1cr,1.e:l us:: of :his :lccJr-nent i,, strict\ proh,t!itc.J. Country of Origin: Mexico ~NOTIFIER® by Honeywell LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION: MARKING: APPROVAL: NOTE: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ! 7272-0028:0503 ! 7272 --SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models FSP-951 , *FSP-951 -SELFT, FSP-951 R, FSP-951T, FSP-951T-ISO, NP-200, NP-200R, and NP-200T analog addressable, photoelectric smoke detectors for open area and duct installations. Models FSP-951T, *FSP-951T-SELFT, FSP-951T-ISO and NP-200T have complementary heat detectors. All models are similar except for population/depopulation of components on the Printed Wiring Board for the intended features. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. 24VDC In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating, and UL label. Listed as photoelectric smoke detectors. Detectors are for use with separately listed bases: Model 8710LP (CSFM No. 7300-0028:0173); System Sensor Models 822481 , 8224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); 8200S-LF, 8200SR-LF (CSFM No. 7300-1653:0238); 8501 , 8210LP, 8300-6, 8300-6-IS (CSFM No. 7300-1653:0109). System Sensor duct detector housings Models DNR and DNRW (CSFM No. 3240-1653:0209) and separately listed compatible fire alarm control units. *The Models FSP-951-SELFT and FSP-951T-SELFT are not Listed for use in duct environments. Refer to manufacturer's Installation Manual for details. All models comply with the applicable requirements in ANSI/UL 268, Smoke Detectors for Fire Alarm Systems, 7th Edition. The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fire may include cigarettes burning in the couched or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires include paper burning in a waste container or a grease fire in the kitchen. *Revision 1-27-21 VVWv This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 NBG-12LX Addressable Manual Pull Station ·General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-1 O or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1 .3[131); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Up to 99 NBG-12LX stations per loop on CLIP protocol loops. • Up to 159 NBG-12LX stations per loop on FlashScan® pro- tocol loops. • Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications • Shipping Weight: 9.6 oz. (272.15 g) • Normal operating voltage: 24 VDC. • Maximum SLC loop voltage: 28.0 voe. • Maximum SLC standby current: 375 µA. • Maximum SLC alarm current: 5 mA. • Temperature Range: 32°F to 120°F (0°C to 49°C) • Relative Humidity: 10% to 93% (noncondensing) • For use indoors in a dry location DN-6726:D • H-240 ({;))NOTIFIER® by Honeywell Intelligent/Addressable Devices The NBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-1 O or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG 12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 -159 on FlashScan® systems, 1 -99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word Fl RE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or DN-6726:D • 4/13/2012 -Page 1 of 2 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UUULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA: 67-02-E. • CSFM: 7150-0028:0199. • FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). • BSMI: Cl313066760047. • U.S. Coast Guard. • Lloyd's Register. • FM Approved. Patented: U.S. Patent No. D428,351 ; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ISO 9001 C-1 #1 -i iii ■=I ·I EN51flEIIN5 I MANIFACTIRING QUALITY SYSTEMS ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com ~ Made in the U.S. A. Page 2 of 2 -DN-6726: D • 4/13/2012 " LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING -BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE ! 7150-0028:0199 l 7150--FIRE ALARM PULL BOXES NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Lisa Brant (203) 484-6105 Fax (203) 484-7309 Email: lisa.brant@honeywell.com Page 1 of 1 Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-12-LO, NBG-12LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBG-12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBG-12SP, NOT-BG12LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, rating, and UL label. Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12LO, NBG-12LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB-1/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 1 0-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 LowVoll-c,s,e integ r ated systems November 28, 2021 City of Carlsbad Fire Prevention 1635 Faraday Ave. Carlsbad, CA 92008 Voluntary Fire Alarm System Disclosure Letter Subject: Voluntary Fire Alarm System Disclosure Letter 5051 Avenida Encinas, Carlsbad, CA 92008 TEL (760) 598-4110 FAX (760) 598-4107 Low Voltage Integrated Systems (designer/installer) and the building owner is aware the devices are not required, but the additional devices are for greater life safety protection for the occupants and building protections. The system will be tested and maintained per code requirements. The devices that are not required are: 1. Fire Control Panel with Cellular Dialer. 2. Remote Annunciator. 3. Pull Station. 4. Lobby Horn/Strobe. 5. Smoke Detectors for protection of common area corridors and server room. (selective area smoke detection) In addition to above, there are (7) duct smoke detectors at heat pumps that shall be connected and monitored as supervisory alarms at the fire control panel. All alarm signals shall be monitored by Low Voltage Monitoring Center via dedicated function cellular communicator. Should you have any questions regarding this disclosure and design intent, please contact me direct at 760 598-4110. Sincerely, Lt. i, ._ J ~-} -~ .,,.. , · -~fl,'"t.-{ ;/i"J,,tr1 · Michael Arguijo President, Low Voltage Integrated Systems 1090 Joshua Way Ste A • Vista, California 92081 FIRE •SECURITY• CCTV• ACCESS CONTROL • SOUND• MEDIA LICENSE NO. C10, C16 #791832 email: info @ sdlvis.com